WorldWideScience

Sample records for posterior fixed partial

  1. [Posterior ceramic bonded partial restorations].

    Science.gov (United States)

    Mainjot, Amélie; Vanheusden, Alain

    2006-01-01

    Posterior ceramic bonded partial restorations are conservative and esthetic approaches for compromised teeth. Overlays constitute a less invasive alternative for tooth tissues than crown preparations. With inlays and onlays they are also indicated in case of full arch or quadrant rehabilitations including several teeth. This article screens indications and realization of this type of restorations.

  2. Effect of different surface treatments and retainer designs on the retention of posterior Pd-Ag porcelain-fused-to-metal resin-bonded fixed partial dentures.

    Science.gov (United States)

    Chen, Xiwen; Zhang, Yixin; Zhou, Jinru; Chen, Chenfeng; Zhu, Zhimin; Li, Lei

    2018-02-01

    The aim of this study was to investigate the adhesive property of palladium-silver alloy (Pd-Ag) and the simulated clinical performance of Pd-Ag porcelain-fused-to-metal (PFM), resin-bonded, fixed partial dentures (RBFPDs). A total of 40 Pd-Ag discs (diameter=5 mm) were prepared and divided into the following four groups (n=10): a) No sandblasting, used as a control; and b, 50 µm; c, 110 µm; and d, 250 µm aluminum oxide (Al 2 O 3 ) particles, respectively. Another 50 discs were pre-sandblasted and divided into five groups (n=10) subjected to different treatments: e) Sandblasting, used as a control; f) silane; g) alloy primer; h) silica coating + silane and i) silica coating + alloy primer. All 90 discs were bonded to enamel with Panavia F 2.0 and then subjected to shear bond strength (SBS) testing. The fracture surfaces were examined by scanning electron microscopy. Next, 40 missing maxillary second premolar models were restored with one of the four following RBFPD designs (n=10): I) A premolar occlusal bar combined with molar double rests (MDR); II) both occlusal bars with a wing (OBB); III) a premolar occlusal bar combined with a molar dental band (MDB); and IV) two single rests adjacent to the edentulous space with a wing (SRB) used as a control. All specimens were aged with thermal cycling and mechanical loading. Subsequently, they were loaded until broken. The data were analyzed by one-way analysis of variance. Al 2 O 3 (250 µm) abrasion provided the highest SBS (P<0.05). The alloy primer and silica + silane exhibited increased SBS. Furthermore, fracture analysis revealed that the failure mode varied among the different treatments. Whereas MDB exhibited the highest retention (P<0.05), that of OBB was greater than that of MDR (P<0.05), and the control exhibited the lowest retention. Abrasion with Al 2 O 3 (250 µm) effectively increased the adhesive property of Pd-Ag. Additionally, treatment with the alloy primer and silica coating + silane was able to

  3. Narrow- (3.0 mm) Versus Standard-Diameter (4.0 and 4.5 mm) Implants for Splinted Partial Fixed Restoration of Posterior Mandibular and Maxillary Jaws: A 5-Year Retrospective Cohort Study.

    Science.gov (United States)

    Pieri, Francesco; Forlivesi, Caterina; Caselli, Ernesto; Corinaldesi, Giuseppe

    2017-04-01

    Evidence concerning predictability of narrow-diameter implants (NDIs) (3.0 mm) and standard-diameter implants (SDIs) (4.0 to 4.5 mm) supporting fixed partial dentures (FPDs) in posterior mandibular and maxillary jaws. All patients treated with at least two adjacent NDIs or SDIs according to available bone thickness and with a minimum follow-up of 5 years after placement were invited to undergo a clinical and radiologic examination. Outcome measures were implant and FPD failures, biologic and prosthetic complications, and marginal bone loss. A total of 107 out of 127 patients attended the examination: 49 (113 implants) of the NDI group, and 58 (126 implants) of the SDI group. Two NDIs failed in one patient versus four SDIs in four patients (P = 0.37). One FPD failed in the NDI group versus two FPDs in the SDI group (P >0.99). Nine biologic complications occurred in the NDI group and twelve in the SDI group (P = 0.81). Twelve prosthetic complications occurred in the NDI group and only two in the SDI group (P = 0.001). Peri-implant marginal bone loss at 5 years was 0.95 ± 0.84 mm for the NDI group and 1.2 ± 0.86 mm for the SDI group (P = 0.06). Five-year data indicate that FPD treatment in posterior mandibular and maxillary jaws with NDIs was as reliable as with SDIs, although NDIs showed a higher risk of prosthetic complications.

  4. [Resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    Kreulen, C.M.; Creugers, N.H.J.

    2013-01-01

    A resin-bonded fixed partial denture is a prosthetic construction which can replace I or several teeth in an occlusal system and which comprises a pontic element which is adhesively attached to 1 or more abutment teeth. To compensate for the limited shear strength of the adhesive layer, the Jixed

  5. Precise Point Positioning with Partial Ambiguity Fixing.

    Science.gov (United States)

    Li, Pan; Zhang, Xiaohong

    2015-06-10

    Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate.

  6. Esthetic double-structure fixed partial dentures.

    Science.gov (United States)

    Ravasini, G; Ugolini, G; Ravasini, F

    1996-04-01

    A new technical procedure for fixed partial dentures and single inlays allows the use of a metal supporting structure with independent ceramic coverage. The advantages of the technique are the bonding of metal to beveled dentinal margins with conventional cement and the acid-etched resin composite cementation of the ceramic, which permits more conservative preparation of the teeth. The complexity of the structure, the laboratory costs, and the doubling of the cementation procedures are the main disadvantages of the technique.

  7. Partial rectangular metric spaces and fixed point theorems.

    Science.gov (United States)

    Shukla, Satish

    2014-01-01

    The purpose of this paper is to introduce the concept of partial rectangular metric spaces as a generalization of rectangular metric and partial metric spaces. Some properties of partial rectangular metric spaces and some fixed point results for quasitype contraction in partial rectangular metric spaces are proved. Some examples are given to illustrate the observed results.

  8. International comparative evaluation of fixed-bearing non-posterior-stabilized and posterior-stabilized total knee replacements.

    Science.gov (United States)

    Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen

    2014-12-17

    Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero

  9. A direct bonded fixed partial dental prosthesis: A clinical report

    OpenAIRE

    Tanoue, Naomi; Tanaka, Takuo

    2015-01-01

    A direct bonded fixed partial dental prosthesis, with a composite resin denture tooth as a pontic, a tri-n-butylborane initiated adhesive resin, and screw posts for reinforcement, was still functioning after an observation period of 20 years. The prosthesis was found to be reliable for long-term clinical use when chemically and mechanically reinforced.

  10. International comparative evaluation of knee replacement with fixed or mobile-bearing posterior-stabilized prostheses.

    Science.gov (United States)

    Graves, Stephen; Sedrakyan, Art; Baste, Valborg; Gioe, Terence J; Namba, Robert; Martínez Cruz, Olga; Stea, Susanna; Paxton, Elizabeth; Banerjee, Samprit; Isaacs, Abby J; Robertsson, Otto

    2014-12-17

    Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard

  11. Fixed Points of Multivalued Contractive Mappings in Partial Metric Spaces

    Directory of Open Access Journals (Sweden)

    Abdul Rahim Khan

    2014-01-01

    Full Text Available The aim of this paper is to present fixed point results of multivalued mappings in the framework of partial metric spaces. Some examples are presented to support the results proved herein. Our results generalize and extend various results in the existing literature. As an application of our main result, the existence and uniqueness of bounded solution of functional equations arising in dynamic programming are established.

  12. Multidisciplinary approach to restoring anterior maxillary partial edentulous area using an IPS Empress 2 fixed partial denture: a clinical report.

    Science.gov (United States)

    Dundar, Mine; Gungor, M Ali; Cal, Ebru

    2003-04-01

    Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.

  13. Versatility of PEEK as a fixed partial denture framework.

    Science.gov (United States)

    Sinha, Nikita; Gupta, Nidhi; Reddy, K Mahendranadh; Shastry, Y M

    2017-01-01

    Materials used for fixed partial denture (FPD) frameworks have had properties of excellent strength, durability, and biocompatibility. Some of the materials which have been used till date include alloys, ceramics, and high-performance polymers such as zirconia, Ni-Cr, lithium disilicate, and so on. All these, though excellent, have their advantages and disadvantages. Hence, the search has always been on for a better material. One such material, which has made its foray into dentistry in the recent times, is polyetheretherketone (PEEK). It is a semicrystalline thermoplastic material. PEEK has an excellent chemical resistance and mechanical properties that are retained at high temperatures. The versatility of PEEK as a dental material for FPD framework was evaluated in this case report.

  14. Clinical study on the success of posterior monolithic zirconia crowns and fixed dental prostheses: preliminary report

    Directory of Open Access Journals (Sweden)

    Merve Bankoğlu Güngör

    2017-09-01

    Full Text Available Objective: The purpose of this report was to present preliminary clinical results regarding the success rates and technical outcomes of posterior monolithic zirconia single tooth crowns (STs and fixed dental prostheses (FDPs. Materials and Method: Thirty-four patients received 43 posterior monolithic zirconia restorations as single tooth crowns (STs and/or fixed dental prostheses (FDPs, which were fabricated using a CAD-CAM (Computer Aided Design - Computer Aided Manufacturing system. At baseline and every 6 months, the restorations were examined for survival and technical outcomes. Success of the restorations was defined as the restoration remaining in situ, with no need for removal or replacement at follow-up visits. Technical outcomes were evaluated with a modified version of the United States Public Health Services criteria. Survival of restorations was estimated by using the Kaplan-Meier survival analysis. For each restoration, duration of follow-up was calculated from the time of placement to the date of its first failure. Results: After a mean observation period of 18.6 ± 3.9 months (between 8-24 months, cumulative survival rates were 86.7% and 92.3% for STs and FDPs, respectively. Technical evaluation revealed good marginal adaptation and crown contours; however, modifications were needed for shade and occlusion of restorations. Conclusion: These preliminary results revealed high survival rate and generally successful technical outcomes for posterior monolithic zirconia STs and FDPs.

  15. Fatigue Fracture Strength of Implant-Supported Full Contour Zirconia and Metal Ceramic Fixed Partial Dentures

    Directory of Open Access Journals (Sweden)

    Fariborz Vafaee

    2017-10-01

    Full Text Available Objectives: Zirconia restorations have been suggested as a more durable and more appealing alternative to metal restorations. However, their mechanical properties may be negatively affected by fatigue due to superficial stresses or low temperature degradation. This study aimed to assess the fatigue fracture strength of three-unit implant-supported full contour zirconia and pre-sintered cobalt-chromium (Co-Cr alloy posterior fixed partial dentures (FPDs.Materials and Methods: In this in-vitro experimental study, 28 posterior three-unit implant-supported FPDs were fabricated of full contour zirconia and pre-sintered Co-Cr alloy, and were cemented on implant abutments. To simulate the oral environment, FPDs were subjected to 10,000 thermal cycles between 5-55°C for 30 seconds, and were then transferred to a chewing simulator (100,000 cycles, 50 N, 0.5 Hz. Afterwards, fatigue fracture strength was measured using a universal testing machine. Data were analyzed by Mann-Whitney U test.Results: The mean and standard deviation of fracture strength were 2108.6±440.1 N in full contour zirconia, and 3499.9±1106.5 N in pre-sintered Co-Cr alloy. According to Mann- Whitney U test, the difference in this respect was statistically significant between the two groups (P=0.007.Conclusions: Since the fracture strength values obtained in the two groups were significantly higher than the maximum mean masticatory load in the oral environment, both materials can be used for fabrication of posterior three-unit FPDs, depending on the esthetic demands of patients.

  16. Posterior open occlusion management by registration of overlay removable partial denture: A clinical report

    Science.gov (United States)

    Nosouhian, Saeid; Davoudi, Amin; Derhami, Mohammad

    2015-01-01

    This clinical report describes prosthetic rehabilitation of posterior open bite relationship in a patient with several missing teeth and skeletal Class III malocclusion. Primary diagnostic esthetic evaluations were performed by mounting casts in centric relation and estimating lost vertical dimension of occlusion. Exclusive treatments were designated by applying overlay removable partial denture with external attachment systems for higher retentions. PMID:26929544

  17. Partial absence of the posterior semicircular canal in Alagille syndrome: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Bernadette; Egelhoff, John; Benton, Corning [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati (United States); Goold, Amy [Tripler Army Medical Center, Family Practice, Honolulu, HI (United States)

    2006-09-15

    We report a case of bilateral partial absence of the posterior semicircular canals (with normal lateral semicircular canals) imaged with CT in a patient with Alagille syndrome. Similar histologic findings have been reported in the pathology literature. This association has been previously reported only for Waardenburg syndrome in the imaging literature. We review the imaging findings and embryology of the semicircular canals, and suggest that this abnormality is specific to patients with Alagille or Waardenburg syndrome. (orig.)

  18. Partial absence of the posterior semicircular canal in Alagille syndrome: CT findings

    International Nuclear Information System (INIS)

    Koch, Bernadette; Egelhoff, John; Benton, Corning; Goold, Amy

    2006-01-01

    We report a case of bilateral partial absence of the posterior semicircular canals (with normal lateral semicircular canals) imaged with CT in a patient with Alagille syndrome. Similar histologic findings have been reported in the pathology literature. This association has been previously reported only for Waardenburg syndrome in the imaging literature. We review the imaging findings and embryology of the semicircular canals, and suggest that this abnormality is specific to patients with Alagille or Waardenburg syndrome. (orig.)

  19. Effects of fixed functional therapy on tongue and hyoid positions and posterior airway.

    Science.gov (United States)

    Ozdemir, Fulya; Ulkur, Feyza; Nalbantgil, Didem

    2014-03-01

    To evaluate how therapy with a fixed functional appliance affects airway dimensions, dentoalveolar changes, and tongue and hyoid positions. A retrospective study was carried out on 46 pre- and posttreatment lateral cephalometric radiographs of 23 post-peak Class II patients (12 girls, 11 boys) treated with a Forsus Fatigue Resistant Device (FRD) appliance. The radiographies were taken at the start and at the end of Forsus FRD appliance therapy when a Class I or overcorrected Class I canine and molar relationship was achieved. The process took an average of 5 months 13 days ± 1 month 4 days. Skeletal and dental parameters were measured using Dolphin software, and the sagittal airway area was measured by AutoCAD software. Analyses of the pre- and posttreatment means revealed that there was no statistically significant skeletal correction of the sagittal malocclusion; increase of lower incisor inclination, decrease of upper incisor inclination, decrease of interincisal angle, and rotation of occlusal plane all contributed to the reduction of overjet. The tongue area and intermaxillary space area increased in response to these dentoalveolar changes; however, there was no statistically significant change in the hyoid position or the oropharyngeal area between the two time points. The dentoalveolar changes produced by Forsus FRD appliance did not cause any significant posterior airway changes in young adult patients.

  20. [Posterior partial trochanteric osteotomy for the treatment of the roof involved acetabular fractures].

    Science.gov (United States)

    Wang, Pan-Feng; Xu, Shuo-Gui; Zhang, Chun-Cai; Fu, Qing-Ge; Zhang, Yun-Tong; Liu, Xin-Wei; Niu, Yun-Fei; Tang, Yang

    2013-11-01

    To introduce a new trochanteric osteotomy,and evaluate the outcome of the procedure combined a posterior lateral approach in treating acetabular fractures which involving the roof. Between March 2007 and Novmber 2010,30 patients with displaced acetabular fractures involving the dome need trochanteric osteotomy were retrospectively reviewed. There were 21 males and 9 females,ranging in age from 18 to 70 years with an average of 35.2 years at the time of injury. According to Letournel-Judet classification, there were 10 posterior wall fractures,7 posterior column fractures,5 transverse fractures, 2 T-shape fractures, 1 transverse associated with posterior wall fracture, 3 posterior column and wall fractures and 2 bicolumn fractures. The standards of Matta,the modified Merle d'Aubigne-Postel, Medical Research Council were respectively used to evaluate the reduction result, function of hip joint and the strength of hip abduction. All patients were followed up with an average time of 25 months (18 to 40) and all osteotomy sites obtained bone union with an average time of 8.4 weeks (6 to 12). No bone non-union, bone block displaceing, internal fixation looseing and breaking,infection of deep part were found. Seventeen patients got anatomic reduction, 12 got satisfied reduction, and 1 got unsatisfied result according to the criteria of Matta. At final follow-up, function of hip joint obtained excellent results in 11 cases, good in 15, fair in 3 and poor in 1. The strength of the abductors of 3 patients were grade 4 and 27 patients were grade 5. Posterior partial great trochanteric osteotomy can enhance the exposure and provide a more accurate reduction and degrade the difficulty of acetabular fracture fixation without increasing the risk of complications. The method provide a new way for the treatment of the roof involved acetabular fractures.

  1. Fracture strength and bending of all-ceramic and fiber-reinforced composites in inlay-retained fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Serkan Saridag

    2012-06-01

    Conclusions: Zirconia-based ceramic inlay-retained fixed partial dentures demonstrated the highest fracture strength. The fiber-reinforced composite inlay-retained fixed partial dentures demonstrated higher bending values than did the all-ceramic inlay-retained fixed partial dentures.

  2. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up.

    Science.gov (United States)

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M

    2016-01-01

    In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan-Meier method. None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study.

  3. Giant partially thrombosed 4 th ventricular posterior inferior cerebellar artery aneurysm; microsurgical management

    Directory of Open Access Journals (Sweden)

    Forhad Hossain Chowdhury

    2014-01-01

    Full Text Available A 42-year-old woman presented with a 3-month history of progressive occipital headache, vomiting, walking difficulty, and repeated fall. She had no history of sudden and severe headache. She had positive cerebellar signs, predominantly on the right side. Computerized tomography (CT scan, CT angiogram, and magnetic resonance image (MRI of the brain showed suspected partially thrombosed giant 4 th ventricular posterior inferior cerebellar artery aneurysm. Patient developed severe hypersensitivity reaction during both CT scan and MRI after contrast injection. Though needed, digital subtraction angiogram (DSA of cerebral vessels was not done. The aneurysm was managed by microsurgical clipping of the aneurysm neck and partial excision of thrombosed aneurysm. Here, we report the details of management of these difficult giant aneurysm without DSA.

  4. Marginal Vertical Discrepancies of Monolithic and Veneered Zirconia and Metal-Ceramic Three-Unit Posterior Fixed Dental Prostheses.

    Science.gov (United States)

    Lopez-Suarez, Carlos; Gonzalo, Esther; Pelaez, Jesus; Serrano, Benjamin; Suarez, Maria J

    2016-01-01

    The aim of this study was to investigate and compare the marginal fit of posterior fixed dental prostheses (FDPs) made of monolithic and veneered computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia ceramic with metal-ceramic posterior FDPs. Thirty standardized steel dies were prepared to receive posterior three-unit FDPs. Specimens were randomly divided into three groups (n = 10): (1) metal-ceramic (control group), (2) veneered zirconia, and (3) monolithic zirconia. All FDPs were cemented using a glass-ionomer cement. The specimens were subjected to thermal cycling (5°C to 55°C). A scanning electron microscope (SEM) with a magnification of ×500 was used for measurements. The data were statistically analyzed using one-way analysis of variance and paired t test. Both zirconia groups showed similar vertical marginal discrepancies, and no significant differences (P = .661) in marginal adaptation were observed among the groups. No differences were observed in either group in marginal discrepancies between surfaces or abutments. Monolithic zirconia posterior FDPs exhibit similar vertical marginal discrepancies to veneered zirconia posterior FDPs. No influence of localization measurements was observed.

  5. Evaluation of metal-polymeric fixed partial prosthesis using optical coherence tomography

    Science.gov (United States)

    Sinescu, C.; Negrutiu, M. L.; Duma, V. F.; Marcauteanu, C.; Topala, F. I.; Rominu, M.; Bradu, A.; Podoleanu, A. Gh.

    2013-11-01

    Metal-Polymeric fixed partial prosthesis is the usual prosthetic treatment for many dental patients. However, during the mastication the polymeric component of the prosthesis is fractured and will be lost. This fracture is caused by the material defects or by the fracture lines trapped inside the esthetic components of the prosthesis. This will finally lead to the failure of the prosthetic treatment. Nowadays, there is no method of identification and forecast for the materials defects of the polymeric materials. The aim of this paper is to demonstrate the capability of Optical Coherence Tomography (OCT) as a non-invasive clinical method that can be used for the evaluation of metal-polymeric fixed partial prostheses. Twenty metal-polymeric fixed partial prostheses were used for this study. The esthetic component of the prostheses has been Adoro (Ivoclar). Optical investigations of the metal prostheses have revealed no material defects or fracture lines. All the prostheses were temporary cemented in the oral cavities of the patients for six month. The non-invasive method used for the investigations was OCT working in Time Domain mode at 1300 nm. The evaluations of the prostheses were performed before and after their cementation in the patient mouths. All the imagistic results were performed in 2D and than in 3D, after the reconstruction. The results obtained after the OCT evaluation allowed for the identification of 4 metal-polymeric fixed partial prostheses with material defects immediately after finishing the technological procedures. After 6 month in the oral environment other 3 fixed partial prostheses revealed fracture lines. In conclusion, OCT proved to be a valuable tool for the noninvasive evaluation of the metal-polymeric fixed partial prostheses.

  6. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  7. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    Science.gov (United States)

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  8. Posterior Femoral Single Limb Osteotomy for the Removal of Well-Fixed Modular Femoral Neck Components

    Directory of Open Access Journals (Sweden)

    Keith A Fehring

    2017-07-01

    Full Text Available Modular neck femoral components were introduced to optimize femoral neck anteversion, leg length, offset, and stability in total hip arthroplasty. However, concerns have been raised in recent years regarding early failure of these implants due to corrosion, pseudotumor, as well as fracture of the modular neck. Removing modular neck femoral implants is challenging as removal of the modular femoral neck leaves a proximally coated femoral stem level with the proximal bone of the femoral neck. We describe a posterior femoral single limb osteotomy  (posterior cut of an extended trochanteric osteotomy for the removal of a modular neck femoral component.

  9. On 0-Complete Partial Metric Spaces and Quantitative Fixed Point Techniques in Denotational Semantics

    Directory of Open Access Journals (Sweden)

    N. Shahzad

    2013-01-01

    Full Text Available In 1994, Matthews introduced the notion of partial metric space with the aim of providing a quantitative mathematical model suitable for program verification. Concretely, Matthews proved a partial metric version of the celebrated Banach fixed point theorem which has become an appropriate quantitative fixed point technique to capture the meaning of recursive denotational specifications in programming languages. In this paper we show that a few assumptions in statement of Matthews fixed point theorem can be relaxed in order to provide a quantitative fixed point technique useful to analyze the meaning of the aforementioned recursive denotational specifications in programming languages. In particular, we prove a new fixed point theorem for self-mappings between partial metric spaces in which the completeness has been replaced by 0-completeness and the contractive condition has been weakened in such a way that the new one best fits the requirements of practical problems in denotational semantics. Moreover, we provide examples that show that the hypothesis in the statement of our new result cannot be weakened. Finally, we show the potential applicability of the developed theory by means of analyzing a few concrete recursive denotational specifications, some of them admitting a unique meaning and others supporting multiple ones.

  10. A Contraction Fixed Point Theorem in Partially Ordered Metric Spaces and Application to Fractional Differential Equations

    Directory of Open Access Journals (Sweden)

    Xiangbing Zhou

    2012-01-01

    Full Text Available We generalize a fixed point theorem in partially ordered complete metric spaces in the study of A. Amini-Harandi and H. Emami (2010. We also give an application on the existence and uniqueness of the positive solution of a multipoint boundary value problem with fractional derivatives.

  11. OCT and shear-force evaluations of zirconia Fixed Partial Prosthesis processed with a conventional CAD/CAM technology

    Science.gov (United States)

    Zaharia, C.; Gabor, A.; Sinescu, C.; Topala, F. I.; Negrutiu, M. L.; Levai, C. M.; Duma, V. F.; Bradu, A.; Podoleanu, A. Gh.

    2016-03-01

    average value of the force necessary to break the FPPs obtained from the tests is 1750 N. Conclusions. Conventional metal-ceramic fixed partial dentures are still considered the standard for edentulous spaces in the posterior region. Therefore, the resistance of metal-ceramic fixed partial dentures has served in this study as a guide for new ceramics tests. All the values from this study conducted in FPP with zirconia frames were much lower than the values reported for metal ceramic fixed partial dentures (i.e., 2500-3000 N), but higher that 1000 N, which is considered the lowest resistance point to be utilized in the rear region of the oral cavity.

  12. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.

    Science.gov (United States)

    Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina

    2011-11-01

    The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

  13. A fixed partial appliance approach towards treatment of anterior single tooth crossbite: Report of two cases

    Directory of Open Access Journals (Sweden)

    M Gawthaman

    2017-01-01

    Full Text Available Crossbite can be treated using both removable and fixed appliances. This paper describes the report of two cases by a method of treating anterior single tooth in crossbite which is locked out of arch form with a simple fixed partial appliance. Orthodontic treatment was initiated by creating space for the locked out incisor using open coil spring and further corrected using MBT brackets and nitinol archwire for alignment. Treatment goals were achieved, and esthetics and occlusion were maintained postoperatively. Treatment objectives were obtained within a short duration using this technique, and there was an improvement in patients' smile.

  14. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation.

    Science.gov (United States)

    Gonzalo, Esther; Suárez, Maria J; Serrano, Benjamin; Lozano, Jose F L

    2009-12-01

    Marginal discrepancies of zirconia posterior fixed dental prostheses (FDPs) fabricated using various systems have been assessed to determine the quality of the restorations and facilitate clinical use; however, studies are limited and results are ambiguous because of the sample sizes and measurement methods. The purpose of this in vitro study was to compare changes in marginal fit of posterior fixed dental prostheses of 3 zirconia systems manufactured using CAD/CAM technology and metal ceramic posterior fixed dental protheses fabricated with the conventional lost-wax technique, before and after cementation. Forty standardized master steel dies with 2 abutments simulating first mandibular premolars were fabricated to receive a posterior 3-unit FDP (from first molar to first premolar) and divided into 4 groups (n=10): Lava All-Ceramic System, Procera Bridge Zirconia, VITA In-Ceram 2000 YZ, and metal ceramic (control group). All FDPs were prepared for an internal space of 50 microm. The external marginal gap of the restorations was investigated by measuring 30 points in the middle of the buccal and lingual surfaces; therefore, 60 measurements per abutment were recorded. Measurements were made with an image analysis program on the master steel model before and after conventional cementation with a glass ionomer agent (Ketac Cem Easymix). The data obtained were statistically analyzed using 1-way ANOVA, Duncan's multiple range post hoc test, and Student's paired t test (alpha=.05). No significant differences in the vertical marginal fit before and after cementation were recorded for the analyzed groups. The marginal discrepancy of Procera abutments before and after cementation (9 +/-10 microm and 12 +/-9 microm, respectively) was less than that of the other groups. Significant differences (P=.001) were observed in marginal adaptation between Procera Bridge Zirconia and the other groups. The results of this study showed that cementation did not cause a significant

  15. Interdisciplinary treatment for a compensated Class II partially edentulous malocclusion: Orthodontic creation of a posterior implant site.

    Science.gov (United States)

    Chiu, Grace; Chang, Chris; Roberts, W Eugene

    2018-03-01

    A 36-year-old woman with good periodontal health sought treatment for a compensated Class II partially edentulous malocclusion associated with a steep mandibular plane (SN-MP, 45°), 9 missing teeth, a 3-mm midline discrepancy, and compromised posterior occlusal function. She had multiple carious lesions, a failing fixed prostheses in the mandibular right quadrant replacing the right first molar, and a severely atrophic edentulous ridge in the area around the mandibular left first and second molars. After restoration of the caries, the mandibular left third molar served as anchorage to correct the mandibular arch crowding. The mandibular left second premolar was retracted with a light force of 2 oz (about 28.3 cN) on the buccal and lingual surfaces to create an implant site between the premolars. Modest lateral root resorption was noted on the distal surface of the mandibular left second premolar after about 7 mm of distal translation in 7 months. Six months later, implants were placed in the mandibular left and right quadrants; the spaces were retained with the fixed appliance for 5 months and a removable retainer for 1 month. Poor cooperation resulted in relapse of the mandibular left second premolar back into the implant site, and it was necessary to reopen the space. When the mandibular left fixture was uncovered, a 3-mm deep osseous defect on the distobuccal surface was found; it was an area of relatively immature bundle bone, because the distal aspect of the space was reopened after the relapse. Subsequent bone grafting resulted in good osseous support of the implant-supported prosthesis. The relatively thin band of attached gingiva on the implant at the mandibular right first molar healed with a recessed contour that was susceptible to food impaction. A free gingival graft restored soft tissue form and function. This severe malocclusion with a discrepancy index value of 28 was treated to an excellent outcome in 38 months of interdisciplinary treatment

  16. Influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage restorations.

    Science.gov (United States)

    Bakeman, E M; Rego, N; Chaiyabutr, Y; Kois, J C

    2015-01-01

    This study evaluated the influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage ceramic restorations. Forty extracted molars were allocated into four groups (n=10) to test for two variables: 1) the thickness of ceramic (1 mm or 2 mm) and 2) the ceramic materials (a lithium disilicate glass-ceramic [IPS e.max] or leucite-reinforced glass ceramic [IPS Empress]). All ceramic restorations were luted with resin cement (Variolink II) on the prepared teeth. These luted specimens were loaded to failure in a universal testing machine, in the compression mode, with a crosshead speed of 1.0 mm/min. The data were analyzed using two-way analysis of variance and the Tukey Honestly Significantly Different multiple comparison test (α =0.05). The fracture resistance revealed a significant effect for materials (pceramic was not significant (p=0.074), and the interaction between the thickness of ceramic and the materials was not significant (p=0.406). Mean (standard deviation) fracture resistance values were as follows: a 2-mm thickness of a lithium disilicate bonded to tooth structure (2505 [401] N) revealed a significantly higher fracture resistance than did a 1-mm thickness of leucite-reinforced (1569 [452] N) and a 2-mm thickness of leucite-reinforced ceramic bonded to tooth structure (1716 [436] N) (pceramic at 1-mm thickness (2105 [567] N) and at 2-mm thickness. Using a lithium disilicate glass ceramic for partial coverage restoration significantly improved fracture resistance compared to using a leucite-reinforced glass ceramic. The thickness of ceramic had no significant effect on fracture resistance when the ceramics were bonded to the underlying tooth structure.

  17. Design Of a Fixed-Dome Ferrocement Biodigester Built Partiall y Underground

    OpenAIRE

    Marianela de la Caridad Ortiz Alvarez; Hugo Rafael Wainshtok Rivas; Henry Hernández Sotomayor

    2016-01-01

    The analysis, structural design and constructive sequence of a fixed-dome biodigester built partially underground and using ferrocement as construction material under normal work conditions is in this paper developed. The biodigester capacity is 24 m3 and it is composed by a semispherical dome (cover), cylindricalwalls (body) and a circular slab(bottom). The biodigester using ferrocement as construction materialis in agreement with the service guaranty requirements settled for the established...

  18. Thoracic posterior longitudinal ligament ossification in a fixed population; longitudinal radiological observations

    International Nuclear Information System (INIS)

    Ono, Minoru; Russell, W.J.; Kudo, Sho.

    1984-05-01

    All lateral chest radiographs of 34 persons with posterior longitudinal ligament ossification (PLLO) in the thoracic spine were reviewed for date of its onset and its progress. These observations spanned as long as 18 years. Upper mid-thoracic PLLO first appeared under the age of 40, then increased in extent in the vertical axis until the age of 50. Lower thoracic PLLO occurred later than upper mid-thoracic PLLO. In the lower thoracic and lumbar regions, degeneration of the vertebrae and discs apparently were focal factors which triggered the development of thoracic PLLO. PLLO apparently developed in a different way in the upper and mid-thoracic regions, where the vertebrae and discs were unremarkable at the time of its initial appearance, and degenerative abnormalities did not predispose to it. (author)

  19. All-ceramic inlay-retained fixed dental prostheses for replacing posterior missing teeth: A systematic review.

    Science.gov (United States)

    Castillo-Oyagüe, Raquel; Sancho-Esper, Rocío; Lynch, Christopher D; Suárez-García, María-Jesús

    2018-01-01

    To evaluate the current status of all-ceramic inlay-retained fixed dental prostheses (CIR-FDPs) for the replacement of posterior teeth. Screening of titles and abstracts, full-text analysis for inclusion eligibility, quality assessment, data extraction and evaluation of the scientific evidence were performed independently by two reviewers. The electronic databases MEDLINE/PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and Compludoc were searched with no restriction to publication date or language. The quality of the studies was evaluated through: the original 'QDP' ('Questionnaire for selecting articles on Dental Prostheses') (for research papers); the 'Guidelines for managing overviews' of the Evidence-Based Medicine Working Group (for reviews); the Cochrane risk of bias tool; and the GRADE scale for grading scientific evidence. This review started with 4942 articles, which were narrowed down to 23 according to the selection criteria. The data was not statistically treated because of the heterogeneity of the studies. Zirconia-based CIR-FDPs may be recommended for restoring posterior single missing teeth, although the prosthesis/tooth bonded interface has yet to be improved. The addition of lateral wings to the classical inlay preparation seems promising. The weakest parts of CIR-FDPs are the connectors and retainers, while caries and endodontic problems are the most common biological complications. The fabrication of CIR-FDPs with monolithic zirconia may eliminate chipping problems. A three-unit CIR-FDP is a viable treatment option for replacing a posterior missing tooth. Appropriate case selection, abutment preparation and luting procedures may be decisive for clinical success. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Maxillary rehabilitation using fixed and removable partial dentures with attachments: a clinical report.

    Science.gov (United States)

    dos Santos Nunes Reis, José Maurício; da Cruz Perez, Luciano Elias; Alfenas, Bruna Fernandes Moreira; de Oliveira Abi-Rached, Filipe; Filho, João Neudenir Arioli

    2014-01-01

    Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

  1. Prosthetic reconstruction using gingiva-colored ceramic agent in fixed partial restoration in a 24-year old patient

    Directory of Open Access Journals (Sweden)

    Sadaqah NR

    2012-11-01

    Full Text Available Nasrin R Sadaqah,1 Jawad Ali Abu Tair21Department of Prosthodontics, 2Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Arab American University, Jenin, Palestinian TerritoryAbstract: Achieving an optimal esthetic result when replacing missing anterior teeth with a fixed partial denture can be a challenge. This is especially true when interdisciplinary treatment is needed and the patient refuses this for personal or financial reasons. Here we report a clinical case where a fixed partial denture was used to change the incisor relationship and to restore the normal tooth and gingival tissue shape, morphology, and relationship by including artificial gingiva within the fixed partial denture when the patient refused lengthy and costly multispecialty treatment options.Keywords: gingival porcelain, fixed partial denture, diagnostic waxup, provisional restoration

  2. Energy-Efficient Power Allocation for Fixed-Gain Amplify-and-Forward Relay Networks with Partial Channel State Information

    KAUST Repository

    Zafar, Ammar; Alouini, Mohamed-Slim; Chen, Yunfei; Radaydeh, Redha M.

    2012-01-01

    In this letter, energy-efficient transmission and power allocation for fixed-gain amplify-and-forward relay networks with partial channel state information (CSI) are studied. In the energy-efficiency problem, the total power consumed is minimized

  3. Functional and Esthetic Comparison of Metal-Ceramic and All-Ceramic Posterior Three-Unit Fixed Dental Prostheses.

    Science.gov (United States)

    Nicolaisen, Maj H; Bahrami, Golnosh; Schropp, Lars; Isidor, Flemming

    2016-01-01

    The aim of this study was to assess functional and esthetic satisfaction plus evaluate changes in oral health-related quality of life (OHRQoL) using the Oral Health Impact Profile (OHIP-14) after insertion of a metal-ceramic (MC-FDP) or a veneered zirconia all-ceramic (AC-FDP) posterior three-unit fixed dental prosthesis (FDP). Additionally, patients' and professionals' esthetic evaluations were compared. A convenience sample of 34 patients was randomized to receive a MC-FDP (n = 17) or an AC-FDP (n = 17). Patients were assessed using the OHIP-14 and also answered a questionnaire regarding satisfaction with function and esthetics using visual analog scales (VAS) before treatment and after 2 weeks, after 3 months, and after 1, 2, and 3 years. A fully dentate control group (n = 20) was also assessed using the OHIP-14. The operator and another observer evaluated the esthetics of the FDPs using VAS. The patients assessed the two FDP types similarly for all parameters. In contrast, there was a statistically significant difference in OHIP-14 results between the treated patients and the control group before treatment. After treatment, a statistically significant improvement in OHIP-14 was observed at all examinations. Patients were highly satisfied with the function and esthetics of the FDPs. The overall satisfaction with esthetics was statistically significantly higher among the patients than among the professionals at three out of five examinations. The patients experienced improved OHRQoL and increased satisfaction with function and esthetics after receiving a posterior three-unit FDP. No important differences were observed between the two types of FDPs when evaluated by the patient or the professionals.

  4. Partial-coverage posterior ceramic restorations. Part 1: a return to diligence.

    Science.gov (United States)

    Liebenberg, W H

    2001-01-01

    The application of multisurfaced tooth-colored restorations in the posterior dentition is an exercise in risk tolerance when dentin occupies the bulk of the tooth substrate. Not only is interfacial integrity capricious, but also a recent in vivo study has confirmed that dentin bond strengths deteriorate with time. Although the literature is replete with esthetic guidelines for posterior restitution, most practicing clinicians appreciate the prime tenet that clinical success involves more than esthetic realism in the posterior dentition. Success with indirect ceramic restorations is dependent on interfacial integrity, which, although multitudinous, is contingently related to operative competence. Innovative clinical techniques are described in this two-part article, along with a discussion of the probationary status of current adhesive options and the need for excellence in all phases of this demanding restorative sequence. Restorative success in the posterior dentition is profoundly influenced by the variability of operative competence and diligence. This article discusses the precincts of posterior indirect ceramic restorations and submits a number of innovative solutions to the clinical challenge.

  5. Fixed point and anomaly mediation in partial {\\boldsymbol{N}}=2 supersymmetric standard models

    Science.gov (United States)

    Yin, Wen

    2018-01-01

    Motivated by the simple toroidal compactification of extra-dimensional SUSY theories, we investigate a partial N = 2 supersymmetric (SUSY) extension of the standard model which has an N = 2 SUSY sector and an N = 1 SUSY sector. We point out that below the scale of the partial breaking of N = 2 to N = 1, the ratio of Yukawa to gauge couplings embedded in the original N = 2 gauge interaction in the N = 2 sector becomes greater due to a fixed point. Since at the partial breaking scale the sfermion masses in the N = 2 sector are suppressed due to the N = 2 non-renormalization theorem, the anomaly mediation effect becomes important. If dominant, the anomaly-induced masses for the sfermions in the N = 2 sector are almost UV-insensitive due to the fixed point. Interestingly, these masses are always positive, i.e. there is no tachyonic slepton problem. From an example model, we show interesting phenomena differing from ordinary MSSM. In particular, the dark matter particle can be a sbino, i.e. the scalar component of the N = 2 vector multiplet of {{U}}{(1)}Y. To obtain the correct dark matter abundance, the mass of the sbino, as well as the MSSM sparticles in the N = 2 sector which have a typical mass pattern of anomaly mediation, is required to be small. Therefore, this scenario can be tested and confirmed in the LHC and may be further confirmed by the measurement of the N = 2 Yukawa couplings in future colliders. This model can explain dark matter, the muon g-2 anomaly, and gauge coupling unification, and relaxes some ordinary problems within the MSSM. It is also compatible with thermal leptogenesis.

  6. Relevance of variations in the opposing dentition for the functionality of fixed and removable partial dentures: a systematic review.

    Science.gov (United States)

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a "biometric quality" tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  7. Relevance of Variations in the Opposing Dentition for the Functionality of Fixed and Removable Partial Dentures: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Bernhard Pommer

    2012-01-01

    Full Text Available The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  8. [Computer aided design for fixed partial denture framework based on reverse engineering technology].

    Science.gov (United States)

    Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2006-03-01

    To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.

  9. Comparison of Treatment Outcomes in Partially Edentulous Patients with Implant-Supported Fixed Prostheses and Removable Partial Dentures.

    Science.gov (United States)

    Nogawa, Toshifumi; Takayama, Yoshiyuki; Ishida, Keita; Yokoyama, Atsuro

    The aim of this study was to compare masticatory performance, occlusal force, and oral health-related quality of life (OHRQoL) in patients with mandibular distal-extension edentulism between those with implant-supported fixed prostheses (ISFPs) and those with removable partial dentures (RPDs), and to evaluate relationships among them. Subjects were recruited from patients using ISFPs or RPDs for mandibular distal-extension edentulism. Masticatory performance was evaluated based on the glucose extracted from chewed gummy jelly. Occlusal force was measured with a pressure-sensitive sheet, and data were subjected to computer analysis. The Japanese version of the Oral Health Impact Profile (OHIP-J) was used to evaluate OHRQoL. The masticatory performance, occlusal force, and OHIP-J scores of the ISFP and RPD groups were compared using the Wilcoxon rank-sum test. The relationships among the variables were analyzed using the Spearman rank correlation coefficient test. Multivariate logistic regression analysis was employed with the OHIP-J score as a dependent variable. Nineteen patients with ISFPs and 25 patients with RPDs participated in this study. No significant difference was observed between the two groups with regard to masticatory performance and occlusal force. The OHIP-J score was significantly lower in the ISFP group than in the RPD group. The OHIP-J score had no significant correlation with masticatory performance, but was significantly correlated with occlusal force and the prosthetic method. Multivariate logistic regression analysis showed that younger age, RPDs, and lower occlusal force were significantly associated with a higher OHIP-J summary score. The present results suggest that the difference in masticatory performance and occlusal force between ISFPs and RPDs is small, but ISFPs are superior to RPDs with regard to OHRQoL in patients with mandibular distal-extension edentulism. In addition, there appears to be a slight correlation between the OHIP

  10. Isolated partial tear and partial avulsion of the medial head of gastrocnemius tendon presenting as posterior medial knee pain

    OpenAIRE

    Watura, Christopher; Ward, Anthony; Harries, William

    2010-01-01

    We present a case of medial head of gastrocnemius tendon tear. The type of injury widely reported in the literature is tear of the medial head of gastrocnemius muscle or ‘tennis leg’. We previously reported an isolated partial tear and longitudinal split of the tendon to the medial head of gastrocnemius at its musculotendinous junction. The case we now present has notable differences; the tear was interstitial and at the proximal (femoral attachment) part of the tendon, the patient’s symptoms...

  11. Partial relay selection in underlay cognitive networks with fixed gain relays

    KAUST Repository

    Hussain, Syed Imtiaz; Alouini, Mohamed-Slim; Hasna, Mazen Omar; Qaraqe, Khalid A.

    2012-01-01

    In a communication system with multiple cooperative relays, selecting the best relay utilizes the available spectrum more efficiently. However, selective relaying poses a different problem in underlay cognitive networks compared to the traditional cooperative networks due to interference thresholds to the primary users. In most cases, a best relay is the one which provides the maximum end-to-end signal to noise ratio (SNR). This approach needs plenty of instantaneous channel state information (CSI). The CSI burden could be reduced by partial relay selection. In this paper, a partial relay selection scheme is presented and analyzed for an underlay cognitive network with fixed gain relays operating in the vicinity of a primary user. The system model is adopted in a way that each node needs minimal CSI to perform its task. The best relay is chosen on the basis of maximum source to relay link SNR which then forwards the message to the destination. We derive closed form expressions for the received SNR distributions, system outage, probability of bit error and average channel capacity of the system. The derived results are confirmed through simulations. © 2012 IEEE.

  12. Partial relay selection in underlay cognitive networks with fixed gain relays

    KAUST Repository

    Hussain, Syed Imtiaz

    2012-05-01

    In a communication system with multiple cooperative relays, selecting the best relay utilizes the available spectrum more efficiently. However, selective relaying poses a different problem in underlay cognitive networks compared to the traditional cooperative networks due to interference thresholds to the primary users. In most cases, a best relay is the one which provides the maximum end-to-end signal to noise ratio (SNR). This approach needs plenty of instantaneous channel state information (CSI). The CSI burden could be reduced by partial relay selection. In this paper, a partial relay selection scheme is presented and analyzed for an underlay cognitive network with fixed gain relays operating in the vicinity of a primary user. The system model is adopted in a way that each node needs minimal CSI to perform its task. The best relay is chosen on the basis of maximum source to relay link SNR which then forwards the message to the destination. We derive closed form expressions for the received SNR distributions, system outage, probability of bit error and average channel capacity of the system. The derived results are confirmed through simulations. © 2012 IEEE.

  13. Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength.

    Science.gov (United States)

    Ha, Seung-Ryong; Yang, Jae-Ho; Lee, Jai-Bong; Han, Jung-Suk; Kim, Sung-Hun

    2010-03-01

    The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (ø 4 mm × 6 mm) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheffe test and independent sample t test (α = 0.05). Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

  14. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    Science.gov (United States)

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  15. Some Common Fixed Point Theorems for F-Contraction Type Mappings in 0-Complete Partial Metric Spaces

    Directory of Open Access Journals (Sweden)

    Satish Shukla

    2013-01-01

    Full Text Available We prove some common fixed point theorems for F-contractions in 0-complete partial metric spaces. Our results extend, generalize, and unify several known results in the literature. Some examples are included which show that the generalization is proper.

  16. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Energy Technology Data Exchange (ETDEWEB)

    Borba, Marcia; Bona, Alvaro Della, E-mail: marcia_borb@hotmail.com [Universidade de Passo Fundo (UPF), RS (Brazil). Fac. de Odontologia; Miranda Junior, Walter Gomes; Cesar, Paulo Francisco [Universidade de Sao Paulo (USP), SP (Brazil). Fac. de Odontologia. Dept. de Biomateriais e Bioquimica Oral; Griggs, Jason Allan [Department of Biomedical Materials Science, Dental School, University of Mississippi Medical Center - UMMC, Jackson, MS (United States)

    2013-09-15

    The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm² connector cross-sections using a LAVA® CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross sectional images. Five measuring points were selected, as follows: MG- marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α = 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 μm). OA had the highest median gap dimension (125 μm), followed by the AOT point (105 μm). CA and AW gap width values were statistically similar, 66 and 65 μm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations. (author)

  17. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    Science.gov (United States)

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    International Nuclear Information System (INIS)

    Borba, Marcia; Bona, Alvaro Della

    2013-01-01

    The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm² connector cross-sections using a LAVA® CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross sectional images. Five measuring points were selected, as follows: MG- marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α = 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 μm). OA had the highest median gap dimension (125 μm), followed by the AOT point (105 μm). CA and AW gap width values were statistically similar, 66 and 65 μm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations. (author)

  19. Economic evaluation of single-tooth replacement: dental implant versus fixed partial denture.

    Science.gov (United States)

    Kim, Younhee; Park, Joo-Yeon; Park, Sun-Young; Oh, Sung-Hee; Jung, YeaJi; Kim, Ji-Min; Yoo, Soo-Yeon; Kim, Seong-Kyun

    2014-01-01

    This study assessed the cost-effectiveness from a societal perspective of a dental implant compared with a three-unit tooth-supported fixed partial denture (FPD) for the replacement of a single tooth in 2010. A decision tree was developed to estimate cost-effectiveness over a 10-year period. The survival rates of single-tooth implants and FPDs were extracted from a meta-analysis of single-arm studies. Medical costs included initial treatment costs, maintenance costs, and costs to treat complications. Patient surveys were used to obtain the costs of the initial single-tooth implant or FPD. Maintenance costs and costs to treat complications were based on surveys of seven clinical experts at dental clinics or hospitals. Transportation costs were calculated based on the number of visits for implant or FPD treatment. Patient time costs were estimated using the number of visits and time required, hourly wage, and employment rate. Future costs were discounted by 5% to convert to present values. The results of a 10-year period model showed that a single dental implant cost US $261 (clinic) to $342 (hospital) more than an FPD and had an average survival rate that was 10.4% higher. The incremental cost-effectiveness ratio was $2,514 in a clinic and $3,290 in a hospital for a prosthesis in situ for 10 years. The sensitivity analysis showed that initial treatment costs and survival rate influenced the cost-effectiveness. If the cost of an implant were reduced to 80% of the current cost, the implant would become the dominant intervention. Although the level of evidence for effectiveness is low, and some aspects of single-tooth implants or FPDs, such as satisfaction, were not considered, this study will help patients requiring single-tooth replacement to choose the best treatment option.

  20. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Directory of Open Access Journals (Sweden)

    Marcia Borba

    2013-09-01

    Full Text Available The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs (Y-TZP - LAVA, 3M-ESPE, using a novel methodology based on micro-computed tomography (micro-CT technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05. There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm. OA had the highest median gap dimension (125 µm, followed by the AOT point (105 µm. CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.

  1. Randomized clinical trial of 270° posterior versus 180° anterior partial laparoscopic fundoplication for gastro-oesophageal reflux disease.

    Science.gov (United States)

    Roks, D J; Koetje, J H; Oor, J E; Broeders, J A; Nieuwenhuijs, V B; Hazebroek, E J

    2017-06-01

    Partial fundoplications provide similar reflux control with fewer post-fundoplication symptoms compared with Nissen fundoplication for gastro-oesophageal reflux disease (GORD). The best choice of procedure for partial fundoplication remains unclear. The aim of this study was to compare the outcome of two different types of partial fundoplication for GORD. A double-blind RCT was conducted between 2012 and 2015 in two hospitals specializing in antireflux surgery. Patients were randomized to undergo either a laparoscopic 270° posterior fundoplication (Toupet) or a laparoscopic 180° anterior fundoplication. The primary outcome was postoperative dysphagia at 12 months, measured by the Dakkak score. Subjective outcome was analysed at 1, 3, 6 and 12 months after surgery. Objective reflux control was assessed before and 6 months after surgery. Ninety-four patients were randomized to laparoscopic Toupet or laparoscopic 180° anterior fundoplication (47 in each group). At 12 months, 85 patients (90 per cent) were available for follow-up. Objective scores were available for 76 (81 per cent). Postoperative Dakkak dysphagia score at 12 months was similar in the two groups (mean 5·9 for Toupet versus 6·4 for anterior fundoplication; P = 0·773). Subjective outcome at 12 months demonstrated no significant differences in control of reflux or post-fundoplication symptoms. Overall satisfaction and willingness to undergo surgery did not differ between the groups. Postoperative endoscopy and 24-h pH monitoring showed no significant differences in mean oesophageal acid exposure time or recurrent pathological oesophageal acid exposure. Both types of partial fundoplication provided similar control of GORD at 12 months, with no difference in post-fundoplication symptoms. Registration number: NTR5702 (www.trialregister.nl). © 2017 BJS Society Ltd Published by John Wiley & Sons Ltd.

  2. Effectiveness of Nissen fundoplication versus anterior and posterior partial fundoplications for treatment of gastro-esophageal reflux disease: a systematic review protocol.

    Science.gov (United States)

    Marshall-Webb, Matthew; Peters, Micah D J; Bright, Tim; Watson, David I

    2018-05-01

    The objective of this review is to determine the relative effectiveness of Nissen fundoplication compared to anterior and posterior partial fundoplication in controlling the symptoms of gastro-esophageal reflux disease and reducing their side effect profile in adults.The specific questions posed by this review are: what is the effectiveness of Nissen fundoplication in comparison to anterior partial fundoplication (90 degree, 120 degree and 180 degree) and posterior 270 degree fundoplication in terms of symptom control of gastro-esophageal reflux disease, and what are the side effects of these surgical interventions?

  3. Influence of posterior dental arch length on brain activity during chewing in patients with mandibular distal extension removable partial dentures.

    Science.gov (United States)

    Shoi, K; Fueki, K; Usui, N; Taira, M; Wakabayashi, N

    2014-07-01

    It is well known that shortened dental arch decreases masticatory function. However, its potential to change brain activity during mastication is unknown. The present study investigates the effect of a shortened posterior dental arch with mandibular removable partial dentures (RPDs) on brain activity during gum chewing. Eleven subjects with missing mandibular molars (mean age, 66.1 years) on both sides received experimental RPDs with interchangeable artificial molars in a crossover trial design. Brain activity during gum chewing with RPDs containing (full dental arch) and lacking artificial molars (shortened dental arch) was measured using functional magnetic resonance imaging. Additionally, masticatory function was evaluated for each dental arch type. Food comminuting and mixing ability and the perceived chewing ability were significantly lower in subjects with a shortened dental arch than those with a full dental arch (P chewing with the full dental arch occurred in the middle frontal gyrus, primary sensorimotor cortex extending to the pre-central gyrus, supplementary motor area, putamen, insula and cerebellum. However, middle frontal gyrus activation was not observed during gum chewing with the shortened dental arch. These results suggest that shortened dental arch affects human brain activity in the middle frontal gyrus during gum chewing, and the decreased middle frontal gyrus activation may be associated with decreased masticatory function. © 2014 John Wiley & Sons Ltd.

  4. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.

    Science.gov (United States)

    Uysal, Hakan; Kurtoglu, Cem; Gurbuz, Riza; Tutuncu, Naki

    2005-03-01

    The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72

  5. Comparison of Metal-Ceramic and All-Ceramic Three-Unit Posterior Fixed Dental Prostheses: A 3-Year Randomized Clinical Trial.

    Science.gov (United States)

    Nicolaisen, Maj H; Bahrami, Golnosh; Schropp, Lars; Isidor, Flemming

    2016-01-01

    The aim of this randomized clinical study was to compare the 3-year clinical outcome of metal-ceramic fixed dental prostheses (MC-FDPs) and zirconia all-ceramic fixed dental prostheses (AC-FDPs) replacing a posterior tooth. A sample of 34 patients with a missing posterior tooth were randomly chosen to receive either a MC-FDP (n = 17) or an AC-FDP (n = 17). The FDPs were evaluated at baseline and yearly until 3 years after cementation. They were assessed using the California Dental Association assessment system. Periodontal parameters were measured at the abutment teeth, and the contralateral teeth served as control. The statistical unit was the FDP/patient. The survival rates for MC-FDPs and AC-FDPs were 100%. The success rate was 76% and 71% for MC-FDPs and AC-FDPs, respectively. Three technical complications were observed in the MC-FDP group and five in the AC-FDP group, all chipping fractures of the ceramic veneer. Furthermore, one biologic complication in the MC-FDP group (an apical lesion) was observed. No framework fractures occurred. All patients had optimal oral hygiene and showed no bleeding on periodontal probing at any of the recalls. Only minor changes in the periodontal parameters were observed during the 3 years of observation. Three-unit posterior MC-FDPs and AC-FDPs showed similar high survival rates and acceptable success rates after 3 years of function, and ceramic veneer chipping fracture was the most frequent complication for both types of restorations.

  6. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when

  7. Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.

    Science.gov (United States)

    Jei, J Brintha; Mohan, Jayashree

    2014-03-01

    The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.

  8. Energy-Efficient Power Allocation for Fixed-Gain Amplify-and-Forward Relay Networks with Partial Channel State Information

    KAUST Repository

    Zafar, Ammar

    2012-06-01

    In this report, energy-efficient transmission and power allocation for fixed-gain amplify-and-forward relay networks with partial channel state information (CSI) are studied. In the energy-efficiency problem, the total power consumed is minimized while keeping the signal-to-noise-ratio (SNR) above a certain threshold. In the dual problem of power allocation, the end-to-end SNR is maximized under individual and global power constraints. Closed-form expressions for the optimal source and relay powers and the Lagrangian multiplier are obtained. Numerical results show that the optimal power allocation with partial CSI provides comparable performance as optimal power allocation with full CSI at low SNR.

  9. Energy-Efficient Power Allocation for Fixed-Gain Amplify-and-Forward Relay Networks with Partial Channel State Information

    KAUST Repository

    Zafar, Ammar

    2012-09-16

    In this letter, energy-efficient transmission and power allocation for fixed-gain amplify-and-forward relay networks with partial channel state information (CSI) are studied. In the energy-efficiency problem, the total power consumed is minimized while keeping the signal-to-noise-ratio (SNR) above a certain threshold. In the dual problem of power allocation, the end-to-end SNR is maximized under individual and global power constraints. Closed-form expressions for the optimal source and relay powers and the Lagrangian multiplier are obtained. Numerical results show that the optimal power allocation with partial CSI provides comparable performance as optimal power allocation with full CSI at low SNR. © 2012 IEEE.

  10. Scan Quality and Entrance Skin Dose in Thoracic CT: A Comparison between Bismuth Breast Shield and Posteriorly Centered Partial CT Scans

    International Nuclear Information System (INIS)

    Tappouni, Rafel; Mathers, Bradley

    2012-01-01

    Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with chest CTs obtained both with and without breast shields were reviewed. IQ was evaluated by two radiologists and by measuring Hounsfield units (HUs) and standard deviation (SD) of HU in anterior subcutaneous region. Results. Breast shield and the partial CT scans reduced radiation to the anterior chest by 38% and 16%, respectively. Partial CT increased dose to the posterior chest by 37% and effective dose by 8%. Change in IQ in shield CT was observed in the anterior chest wall. Significant change in IQ was observed in 5/50 cases. The shield caused an increase of 20 HU (P = 0.021) and a 1.86 reduction in SD of HU (P = 0.027) in the anterior compared to posterior subcutaneous regions. Summary. Bismuth breast shield is more effective than the partial CT in reducing entrance skin dose while maintaining image quality

  11. Treatment planning of implants in posterior quadrants.

    Science.gov (United States)

    Jivraj, S; Chee, W

    2006-07-08

    Differences in anatomy and biomechanics make treatment of posterior quadrants with dental implants substantially different to that of anterior areas. Without implants, when posterior teeth were lost, treatment options included a long span fixed partial denture or a removable prosthesis, especially when no terminal abutment was available. Today, with the use of implants, options are available that allow preservation of unrestored teeth.(1) When teeth are missing, implant supported restorations can be considered the treatment of choice from the perspective of occlusal support, preservation of adjacent teeth and avoidance of a removable partial denture.

  12. SU-F-T-208: An Efficient Planning Approach to Posterior Fossa Tumor Bed Boosts Using Proton Pencil Beam Scanning in Fixed-Beam Room

    International Nuclear Information System (INIS)

    Ju, N; Chen, C; Gans, S; Hug, E; Cahlon, O; Chon, B; Tsai, H; Sine, K; Mah, D; Wolden, S; Yeh, B

    2016-01-01

    Purpose: A fixed-beam room could be underutilized in a multi-room proton center. We investigated the use of proton pencil beam scanning (PBS) on a fixed-beam as an alternative for posterior fossa tumor bed (PF-TB) boost treatments which were usually treating on a gantry with uniform scanning. Methods: Five patients were treated with craniospinal irradiation (CSI, 23.4 or 36.0 Gy(RBE)) followed by a PF-TB boost to 54 Gy(RBE) with proton beams. Three PF-TB boost plans were generated for each patient: (1) a uniform scanning (US) gantry plan with 4–7 posterior fields shaped with apertures and compensators (2) a PBS plan using bi-lateral and vertex fields with a 3-mm planning organ-at-risk volume (PRV) expansion around the brainstem and (3) PBS fields using same beam arrangement but replacing the PRV with robust optimization considering a 3-mm setup uncertainty. Results: A concave 54-Gy(RBE) isodose line surrounding the brainstem could be achieved using all three techniques. The mean V95% of the PTV was 99.7% (range: 97.6% to 100%) while the V100% of the PTV ranged from 56.3% to 93.1% depending on the involvement of the brainstem with the PTV. The mean doses received by 0.05 cm"3 of the brainstem were effectively identical: 54.0 Gy(RBE), 53.4 Gy(RBE) and 53.3 Gy(RBE) for US, PBS optimized with PRV, and PBS optimized with robustness plans respectively. The cochlea mean dose increased by 23% of the prescribed boost dose in average from the bi-lateral fields used in the PBS plan. Planning time for the PBS plan with PRV was 5–10 times less than the US plan and the robustly optimized PBS plan. Conclusion: We have demonstrated that a fixed-beam with PBS can deliver a dose distribution comparable to a gantry plan using uniform scanning. Planning time can be reduced substantially using a PRV around the brainstem instead of robust optimization.

  13. SU-F-T-208: An Efficient Planning Approach to Posterior Fossa Tumor Bed Boosts Using Proton Pencil Beam Scanning in Fixed-Beam Room

    Energy Technology Data Exchange (ETDEWEB)

    Ju, N; Chen, C; Gans, S; Hug, E; Cahlon, O; Chon, B; Tsai, H; Sine, K; Mah, D [Procure Treatment Center, Somerset, New Jersey (United States); Wolden, S [Memorial Sloan Kettering Cancer Center, New York, NY (United States); Yeh, B [Mount Sinai Hospital, New York, NY (United States)

    2016-06-15

    Purpose: A fixed-beam room could be underutilized in a multi-room proton center. We investigated the use of proton pencil beam scanning (PBS) on a fixed-beam as an alternative for posterior fossa tumor bed (PF-TB) boost treatments which were usually treating on a gantry with uniform scanning. Methods: Five patients were treated with craniospinal irradiation (CSI, 23.4 or 36.0 Gy(RBE)) followed by a PF-TB boost to 54 Gy(RBE) with proton beams. Three PF-TB boost plans were generated for each patient: (1) a uniform scanning (US) gantry plan with 4–7 posterior fields shaped with apertures and compensators (2) a PBS plan using bi-lateral and vertex fields with a 3-mm planning organ-at-risk volume (PRV) expansion around the brainstem and (3) PBS fields using same beam arrangement but replacing the PRV with robust optimization considering a 3-mm setup uncertainty. Results: A concave 54-Gy(RBE) isodose line surrounding the brainstem could be achieved using all three techniques. The mean V95% of the PTV was 99.7% (range: 97.6% to 100%) while the V100% of the PTV ranged from 56.3% to 93.1% depending on the involvement of the brainstem with the PTV. The mean doses received by 0.05 cm{sup 3} of the brainstem were effectively identical: 54.0 Gy(RBE), 53.4 Gy(RBE) and 53.3 Gy(RBE) for US, PBS optimized with PRV, and PBS optimized with robustness plans respectively. The cochlea mean dose increased by 23% of the prescribed boost dose in average from the bi-lateral fields used in the PBS plan. Planning time for the PBS plan with PRV was 5–10 times less than the US plan and the robustly optimized PBS plan. Conclusion: We have demonstrated that a fixed-beam with PBS can deliver a dose distribution comparable to a gantry plan using uniform scanning. Planning time can be reduced substantially using a PRV around the brainstem instead of robust optimization.

  14. Partial analysis of wind power limit for large disturbance using fixed speed wind turbine

    International Nuclear Information System (INIS)

    Santos Fuentefria, Ariel; Cairo Rodriguez, Daniel; Boza Valerino, Juan Gualberto

    2014-01-01

    The amount of wind power that allow an electric network without losing his stability as known as wind power limit. The wind power limit fundamentally depends on the wind turbine technology and the weakness level of the system. To know the system behaviors in dynamic performance having into account the worst disturbance is a very important matter, a short circuit in one of the most power transference line or the loss of a large generation unit was a large disturbance that can affect system stability. The wind power limit may change with the nature of the disturbance. To know the wind power limit considering this conditions allow use the wind at maximum level. In the present paper the behavior of fixed speed wind turbine for different fault types is analyzed, at those conditions, the wind power is increasing until the system become voltage unstable. For the analysis the IEEE 14 Bus Test Case is used. The Power System Analysis Toolbox (PSAT) package is used for the simulation. (author)

  15. A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants with different surface textures

    DEFF Research Database (Denmark)

    Karlsson, U; Gotfredsen, K; Olsson, C

    1998-01-01

    In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1...

  16. Current bonding systems for resin-bonded restorations and fixed partial dentures made of silver–palladium–copper–gold alloy

    Directory of Open Access Journals (Sweden)

    Hideo Matsumura

    2011-02-01

    Full Text Available This review article describes about the bonding systems for noble metal alloys, bonding techniques of restorations and fixed partial dentures (FPDs made of Ag–Pd–Cu–Au alloys, and their clinical performance. Thione monomers, 6-(4-vinylbenzyl-n-propyl amino-1,3,5-triazine-2,4-dithione (VTD, 6-methacryloyloxyhexyl-2-thiouracil-5-carboxylate (MTU-6, and 10-methacryloxydecyl 6,8-dithiooctanoate (MDDT, has been proved effective for bonding noble metal alloys. An acrylic adhesive consists of the tri-n-butylborane (TBB initiator, methyl methacrylate (MMA monomer liquid with 5% 4-methacryloyloxyethyl trimellitate anhydride (4-META, and poly(methyl methacrylate (PMMA, is being used for bonding metallic restorations to abutment surfaces. Clinical performance of restorations and FPDs made of Ag–Pd–Cu–Au alloys is overall excellent when they are seated with the currently available noble metal bonding systems.

  17. A randomized controlled clinical trial of 3-unit posterior zirconia-ceramic fixed dental prostheses (FDP) with layered or pressed veneering ceramics: 3-year results.

    Science.gov (United States)

    Naenni, Nadja; Bindl, Andreas; Sax, Caroline; Hämmerle, Christoph; Sailer, Irena

    2015-11-01

    The aim of the present pilot study was to test whether or not posterior zirconia-ceramic fixed dental prostheses (FDPs) with pressed veneering ceramic exhibit less chipping than FDPs with layered veneering ceramics. Forty patients (13 female, 27 male; mean age 54 years (range 26.1-80.7 years) in need of one maxillary or mandibular three-unit FDP in the second premolar or molar region were recruited and treated at two separate centers at the University of Zurich according to the same study protocol. The frameworks were made out of zirconia using a CAD/CAM system (Cerec Sirona, Bensheim, Germany). The patients were randomly assigned to either the test group (zirconia frameworks veneered with pressed ceramic; IPS e.max ZirPress, Ivoclar Vivadent AG, Schaan, Liechtenstein; n=20) or the control group (layered veneering ceramic; IPS e.max Ceram, Ivoclar Vivadent AG, Schaan, Liechtenstein; n=20). All FDPs were adhesively cemented and evaluated at baseline (i.e., cementation), at 6 months and at 1 and 3 years of clinical service. The survival of the reconstruction was recorded. The technical outcome was assessed using modified United States Public Health Services (USPHS) criteria. The biologic parameters analyzed at abutment teeth and analogous non-restored teeth included probing pocket depth (PPD), plaque control record (PCR), bleeding on probing (BOP), and tooth vitality (CO2). Data was descriptively analyzed and survival was calculated using Kaplan-Meier statistics. 36 patients (25 female, 11 male; mean age 52.3 years) with 18 test and 18 control FDPs were examined after a mean follow-up of 36 months (95% CI: 32.6-39.1 months). Comparison of groups was done by Crosstabulation showing even distribution of the respective restored teeth amidst the groups. Survival rate was 100% for both test and control FDPs. Chipping of the veneering ceramic tended to occur more frequently in test (n=8; 40%) than in control (n=4; 20%) FDPs, albeit not significantly (p=0.3). No further

  18. Oral health related quality-of-life outcomes of partially edentulous patients treated with implant-supported single crowns or fixed partial dentures.

    Science.gov (United States)

    AlZarea, Bader K

    2017-05-01

    Oral health-related quality of life (OHRQoL) is afflicted by different variables. Limited information is available regarding the impact of different phases of implant therapy on OHRQoL of edentulous patients. This study was carried out to assess the OHRQoL of patients treated with implant-supported single crowns or fixed partial dentures. A total of 79 healthy partially edentulous subjects needing implant therapy were incorporated in this study. Before placement of the implants, the subjects were instructed to fill the original version of OHIP questionnaire. Subsequently patients received titanium oral implants of the ITI® Dental Implant System. After 1st, 2nd and 3rd year of implant placement, patients filled the same OHIP-49 questionnaire. In this manner the impact of implant therapy on OHRQoL by putting in comparison pre- and post-treatment OHIP-49 scores was assessed. Statistical analyses were performed using Statistical Package for the Social Science software (SPSS, version 22, Chicago, IL, USA). Paired t test and Unpaired t test were performed and a statistical significance was set at 5% level of significance ( p disability, psychological disability, social disability were significantly decreased from baseline to 1st year ( p 0.05). All variables were also significantly decreased from baseline to 2nd year and 3rd year ( p 0.05). Patients aged less than 60 years and more than 60 years of age groups differed significantly with respect to OHIP scores measured at 1st year, 2nd year and at 3rd year of implant placement ( p Oral health-related quality-of-life.

  19. Three-dimensional finite element analysis of zirconia all-ceramic cantilevered fixed partial dentures with different framework designs.

    Science.gov (United States)

    Miura, Shoko; Kasahara, Shin; Yamauchi, Shinobu; Egusa, Hiroshi

    2017-06-01

    The purpose of this study were: to perform stress analyses using three-dimensional finite element analysis methods; to analyze the mechanical stress of different framework designs; and to investigate framework designs that will provide for the long-term stability of both cantilevered fixed partial dentures (FPDs) and abutment teeth. An analysis model was prepared for three units of cantilevered FPDs that assume a missing mandibular first molar. Four types of framework design (Design 1, basic type; Design 2, framework width expanded buccolingually by 2 mm; Design 3, framework height expanded by 0.5 mm to the occlusal surface side from the end abutment to the connector area; and Design 4, a combination of Designs 2 and 3) were created. Two types of framework material (yttrium-oxide partially stabilized zirconia and a high precious noble metal gold alloy) and two types of abutment material (dentin and brass) were used. In the framework designs, Design 1 exhibited the highest maximum principal stress value for both zirconia and gold alloy. In the abutment tooth, Design 3 exhibited the highest maximum principal stress value for all abutment teeth. In the present study, Design 4 (the design with expanded framework height and framework width) could contribute to preventing the concentration of stress and protecting abutment teeth. © 2017 Eur J Oral Sci.

  20. Implant-tooth-supported fixed partial prostheses: correlations between in vivo occlusal bite forces and marginal bone reactions.

    Science.gov (United States)

    Akça, Kivanç; Uysal, Serdar; Cehreli, Murat Cavit

    2006-06-01

    To evaluate maximal occlusal bite forces (MOF) and marginal bone level (MBL) changes in patients with implant-tooth-supported fixed partial prostheses (FPP). Twenty nine partially edentulous patients consecutively who received 34 three-occlusal unit FPP with terminal implant and tooth support were subjected to quantification of MOFs using a sub-miniature load cell connected to a data acquisition system and measurement of the MBL changes around implants in digitalized periapical radiographs obtained at prostheses delivery and 24-month follow-up. MOFs for implant support (mean: 353.61 N) significantly differed from tooth support (mean: 275.48 N) (P 0.05). MBL changes at mesial and distal sites of the implants at 24 months of functional loading were 0.28 and 0.097 mm respectively. Although MOFs under functional loading might indicate an increase in load participation for supporting implant, the rigid connection between implant and natural tooth via three-occlusal unit FPP does not jeopardize the time-dependent MBL stability of the implant under functional loads.

  1. A comparative study to check fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate resin reinforced with different materials: An in vitro study.

    Science.gov (United States)

    Gupt, Parikshit; Nagpal, Archana; Samra, Rupandeep Kaur; Verma, Ramit; Kaur, Jasjeet; Abrol, Surbhi

    2017-01-01

    The purpose of the study was to evaluate the fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate (PMMA) resin using different types of reinforcement materials to determine the best among them. Fifty samples were made (10 samples for each group) with autopolymerizing PMMA resin using reinforcement materials (stainless steel wire: looped and unlooped and glass fiber: loose and unidirectional) as 3-unit posterior bridge. The test specimens were divided into five groups depending on the reinforcing material as Group I, II, III, IV, and V; Group I: PMMA unreinforced (control group), Group II: PMMA reinforced with stainless steel wire (straight ends), Group III: PMMA reinforced with stainless steel wire (looped ends), Group IV: PMMA reinforced with unidirectional glass fibers, and Group V: PMMA reinforced with randomly distributed glass fibers. Universal testing machine was used to evaluate and compare the fracture strength of samples. Comparison of mean ultimate force and ultimate stress was done employing one-way analysis of variance and Tukey's post hoc tests. The highest and lowest mean ultimate force and mean ultimate stress were of Group IV and I, respectively. Tukey's post hoc honestly significant difference multiple comparison for mean ultimate force and stress shows the increase in strength to be statistically significant ( P 0.05). Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.

  2. Terminal Posterior Tilted Implants Planned as a Sinus Graft Alternative for Fixed Full-Arch Implant-Supported Maxillary Restoration: A Case Series with 10- to 19-Year Results on 44 Consecutive Patients Presenting for Routine Maintenance.

    Science.gov (United States)

    Fortin, Yvan; Sullivan, Richard M

    2017-02-01

    Posterior maxillary tilted implants are gaining prevalence as an alternative to sinus grafts supporting fixed maxillary restorations. This paper reports long-term results after loading using this technique. Consecutive patients presenting for either routine hygiene maintenance or unplanned emergency care who had received tilted implants as a sinus graft alternative to support fixed fully implant-supported restoration of an edentulous maxilla and were followed for a minimum of 10 years from initial implant placement were included in this evaluation. Forty-four patients were identified: 40 with bilateral tilted implants and 4 with one tilted and one axial posterior implant. Eight patients received one-piece fixed porcelain-to-gold screw-retained restorations, and thirty-six patients received a fully implant-supported patient-removable Marius Bridge. Seventy-nine out of 84 originally loaded posterior tilted implants survived a minimum of 10 years loading; one tilted implant was lost at 10 years. Eight additional posterior implants were placed for either these lost tilted posterior implants or as proactive supplemental support; one of these replacement tilted implants survived for at least 10 years and is included in the data. All patients have maintained continuous fixed function throughout the follow-up period. Forty-one out of 44 patients continue with the original restoration, 33 without modification or removal of the fixed restoration or implant-connecting bar. One porcelain-to-gold and seven Marius Bridges had framework modifications to accommodate additional implants; 3 Marius Bridge restorations were replaced with a newer generation. Within the limits of this retrospective study, the results show that continuous fixed function of fully implant-supported maxillary restorations using posterior tilted implants in terminal positions of support as a sinus graft alternative combined with axial anterior implants is possible over a prolonged period. Loss of a posterior

  3. Retrospective comparative ten-year study of cumulative survival rates of remaining teeth in large edentulism treated with implant-supported fixed partial dentures or removable partial dentures.

    Science.gov (United States)

    Yamazaki, Seiya; Arakawa, Hikaru; Maekawa, Kenji; Hara, Emilio Satoshi; Noda, Kinji; Minakuchi, Hajime; Sonoyama, Wataru; Matsuka, Yoshizo; Kuboki, Takuo

    2013-07-01

    This study aimed to compare the survival rates of remaining teeth between implant-supported fixed dentures (IFDs) and removable partial dentures (RPDs) in patients with large edentulous cases. The second goal was to assess the risk factors for remaining tooth loss. The study subjects were selected among those who received prosthodontic treatment at Okayama University Dental Hospital for their edentulous space exceeding at least four continuous missing teeth. Twenty-one patients were included in the IFD group and 82 patients were included in the RPD group. Survival rates of remaining teeth were calculated in three subcategories: (1) whole remaining teeth, (2) adjacent teeth to intended edentulous space, and (3) opposing teeth to intended edentulous space. The ten-year cumulative survival rate of the whole remaining teeth was significantly higher in the IFD group (40.0%) than in the RPD group (24.4%). On the other hand, there was no significant difference between two groups in the survival rate of teeth adjacent or opposing to intended edentulous space. A Cox proportional hazard analysis revealed that RPD restoration and gender (male) were the significant risk factors for remaining tooth loss (whole remaining teeth). These results suggest that IFD treatment can reduce the incidence of remaining tooth loss in large edentulous cases. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures.

    Science.gov (United States)

    Furuyama, Chisako; Takaba, Masayuki; Inukai, Mika; Mulligan, Roseann; Igarashi, Yoshimasa; Baba, Kazuyoshi

    2012-08-01

    This study investigated the association between denture status [implant-supported fixed dentures (IDs) and removable partial dentures (RPDs)] and oral health-related quality of life (OHRQoL). Consecutive patients with IDs and RPDs were recruited from the Prosthodontics Departments at Showa University and Tokyo Medical and Dental University. The Japanese version of the Oral Health Impact Profile (OHIP-J-49) was administered to each subject. For each OHIP-J-49 question, the subjects were asked to indicate the frequency with which they had experienced a dental problem during the last month. Responses were recorded on a 5 point Likert rating scale, with 0 being never and 4, very often. Summary scores were calculated and regression analyses conducted to investigate the association between denture status and OHIP-J-49 summary score. In total 79 ID subjects (mean age±SD of 51.7±12.4 years, 44.3% men) and 109 RPD subjects (mean age of 66.5±8.6 years, 30% men) participated after giving informed consent. The regression analysis between the type of treatment and the OHIP-J-49 summary score revealed a significant association with a coefficient of 17.0 (Confidence interval, CI: 10.9-23.1). When age and duration of denture usage, which had significant associations with OHIP-J-49, were included in this model, the regression coefficient remained virtually unchanged at 17.4 (CI: 9.75-25.0), thus indicating little potential confounding by them. OHRQoL in patients with implant-supported fixed dentures is generally less impaired than it is in those patients with RPDs. © 2011 John Wiley & Sons A/S.

  5. Partially thrombosed giant aneurysm arising from a distal anterior inferior cerebellar artery–posterior inferior cerebellar artery variant: A case report

    Directory of Open Access Journals (Sweden)

    Hidetoshi Ooigawa

    2015-09-01

    Full Text Available Anterior inferior cerebellar artery (AICA–posterior inferior cerebellar artery (PICA is a well-known variant in cerebral arteries. However, aneurysms located on the variant are rare and a giant one has not been reported. We report a case of a partially thrombosed giant aneurysm arising from an AICA–PICA variant. The patient was a 42-year-old man who presented with right hearing loss and facial numbness associated with left hemidysesthesia. Magnetic resonance imaging revealed an approximately 3.0-cm mass lesion at the right cerebello-pontine angle (CPA. Angiography showed a partially thrombosed aneurysm arising from the right AICA–PICA. The aneurysm was treated with endovascular trapping and surgical thrombectomy. Although cerebral aneurysm is known to occur at this site, this case provides awareness, that manifestations of aneurysms in the CPA include progressive multiple cranial nerve palsies and sensory disturbance caused by brainstem compression.

  6. Adiabatic Fixed-Bed Gasification of Colombian Coffee Husk Using Air-Steam Blends for Partial Oxidation

    Directory of Open Access Journals (Sweden)

    Javier Bonilla

    2017-01-01

    Full Text Available The increasing energy consumption, mostly supplied by fossil fuels, has motivated the research and development of alternative fuel technologies to decrease the humanity’s dependence on fossil fuels, which leads to pollution of natural sources. Small-scale biomass gasification, using air-steam blends for partial oxidation, is a good alternative since biomass is a neutral carbon feedstock for sustainable energy generation. This research presents results obtained from an experimental study on coffee husk (CH gasification, using air-steam blends for partial oxidation in a 10 kW fixed-bed gasifier. Parametric studies on equivalence ratio (ER (1.53 < ER < 6.11 and steam-fuel (SF ratio (0.23 < SF < 0.89 were carried out. The results show that increasing both SF and ER results in a syngas rich in CH4 and H2 but poor in CO. Also, decreased SF and ER decrease the peak temperature (Tpeak at the gasifier combustion zone. The syngas high heating value (HHV ranged from 3112 kJ/SATPm3 to 5085 kJ/SATPm3 and its maximum value was obtained at SF = 0.87 and ER = 4.09. The dry basis molar concentrations of the species, produced under those operating conditions (1.53 < ER < 6.11 and 0.23 < SF < 0.89, were between 1.12 and 4.1% for CH4, between 7.77 and 13.49% for CO, and between 7.54 and 19.07% for H2. Other species were in trace amount.

  7. Achieving mainstream nitrogen removal through simultaneous partial nitrification, anammox and denitrification process in an integrated fixed film activated sludge reactor.

    Science.gov (United States)

    Wang, Chao; Liu, Sitong; Xu, Xiaochen; Zhang, Chaolei; Wang, Dong; Yang, Fenglin

    2018-07-01

    The anaerobic ammonium oxidation (anammox) is becoming a critical technology for energy neutral in mainstream wastewater treatment. However, the presence of chemical oxygen demanding in influent would result in a poor nitrogen removal efficiency during the deammonification process. In this study, the simultaneous partial nitrification, anammox and denitrification process (SNAD) for mainstream nitrogen removal was investigated in an integrated fixed film activated sludge (IFAS) reactor. SNAD-IFAS process achieved a total nitrogen (TN) removal efficiency of 72 ± 2% and an average COD removal efficiency was 88%. The optimum COD/N ratio for mainstream wastewater treatment was 1.2 ± 0.2. Illumina sequencing analysis and activity tests showed that anammox and denitrifying bacteria were the dominant nitrogen removal microorganism in the biofilm and the high COD/N ratios (≥2.0) leaded to the proliferation of heterotrophic bacteria (Hydrogenophaga) and nitrite-oxidizing bacteria (Nitrospira) in the suspended sludge. Network analysis confirmed that anammox bacteria (Candidatus Kuenenia) could survive in organic matter environment due to that anammox bacteria displayed significant co-occurrence through positive correlations with some heterotrophic bacteria (Limnobacter) which could protect anammox bacteria from hostile environments. Overall, the results of this study provided more comprehensive information regarding the community composition and assemblies in SNAD-IFAS process for mainstream nitrogen removal. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. [Application of single-retainer all-ceramic resin-bonded fixed partial denture in replacing single anterior tooth].

    Science.gov (United States)

    Lili, Yang; Debiao, Du; Ruoyu, Ning; Deying, Chen; Junling, Wu

    2017-08-01

    Objective In this study, we aimed to evaluate the clinical effect of single-retainer all-ceramic resin-bonded fixed partial denture (RBFPD) on the single anterior tooth loss patients. Methods A total of 20 single-retainer all-ceramic RBFPD
were fabricated and evaluated in a two-year follow-up observation. The restorations were examined on the basis of the American Public Health Association (APHA) criteria. Results A total of 20 single-retainer all-ceramic RBFPD achieved class A evaluation after a six-month follow-up observation. One single-retainer all-ceramic RBFPD was classified as class B for secondary caries after a one-year follow-up observation. After a two-year follow-up observation, one single-retainer all-ceramic RBFPD was classified as class B because of secondary caries, and one single-retainer all-ceramic RBFPD was classified as class B because of fracture. Conclusion Single-retainer all-ceramic RBFPD is a promising and optional method in replacing single anterior tooth.

  9. Impact of Removable Partial Dental Prostheses on the Oral Health-Related Quality of Life of a South African Cohort with Varied Distributions of Missing Posterior Teeth.

    Science.gov (United States)

    Khan, Sadika; Chikte, Usuf; Omar, Ridwaan

    2017-10-25

    To determine the impact of removable partial dental prostheses on satisfying the daily functioning and quality of life (QoL) of adult patients with different distributions of missing posterior teeth. A cross-sectional interventional study was carried out on 80 patients having variously distributed posteriorly shortened and interrupted arches. Treatment comprised provision of partial dentures by senior dental students, supervised by senior clinical teachers who had knowledge of the potential benefits of the shortened dental arch (SDA) concept. The Oral Impacts on Daily Performance Index was completed before and 6 months after prosthetic treatment across groups comprising Kennedy Classes I, II, and III arches. Analysis included descriptive statistics and associations and comparisons between variables. Mean age of patients was 57.4 years (SD = 13.1), many were retired (72.2%), and a majority were females (60%). Most patients lived in urban areas (95%), and were largely unemployed (63.3%). At pretreatment, only 31.3% of patients reported having good dental health and satisfaction with their current oral state, while 82.5% said they had a great need for treatment. The negative oral impacts that were most frequently experienced were those of eating (67.5%), smiling (50%), and being emotionally disturbed (63.8%). Post-treatment, 76.3% indicated good oral health and satisfaction with no significant differences between the 3 Kennedy groups. Any further negative impacts were reported mostly for Kennedy Classes I and II. Overall, significant reductions of negative impacts were observed following treatment with dentures, across the 3 Kennedy groups, with respect to improved function, satisfaction, and oral health-related QoL. The findings confirm the reliance by partially dentate patients in all 3 Kennedy groups on dentures for improved oral health, although the possible benefits of the SDA concept as an alternative treatment option was not specifically explored. © 2017 by

  10. Design of adiabatic fixed-bed reactors for the partial oxidation of methane to synthesis gas. Application to production of methanol and hydrogen-for-fuel-cells

    NARCIS (Netherlands)

    Smet, de C.R.H.; Croon, de M.H.J.M.; Berger, R.J.; Marin, G.B.M.M.; Schouten, J.C.

    2001-01-01

    Adiabatic fixed-bed reactors for the catalytic partial oxidn. (CPO) of methane to synthesis gas were designed at conditions suitable for the prodn. of methanol and hydrogen-for-fuel-cells. A steady-state, one-dimensional heterogeneous reactor model was applied in the simulations. Intra-particle

  11. Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment.

    Science.gov (United States)

    Glisić, Mirko; Stamenković, Dragoslav; Grbović, Aleksandar; Todorović, Aleksandar; Marković, Aleksa; Trifković, Branka

    2016-01-01

    Differences between the tooth and implant response to load can lead to many biological and technical implications in the conditions of occlusal forces. The objective of this study was to analyze load distribution in tooth/implant-supported fixed partial dentures with the use of resilient TSA (Titan Shock Absorber, BoneCare GmbH, Augsburg, Germany) abutment and conventional non-resilient abutment using finite element method. This study presents two basic 3D models. For one model a standard non-resilient abutment is used, and on the implant of the second model a resilient TSA abutment is applied. The virtual model contains drawn contours of tooth, mucous membranes, implant, cortical bones and spongiosa, abutment and suprastructure. The experiment used 500 N of vertical force, applied in three different cases of axial load. Calculations of von Mises equivalent stresses of the tooth root and periodontium, implants and peri-implant tissue were made. For the model to which a non-resilient abutment is applied, maximum stress values in all three cases are observed in the cortical part of the bone (maximum stress value of 49.7 MPa). Measurements of stress and deformation in the bone tissue in the model with application of the resilientTSA abutment demonstrated similar distribution; however, these values are many times lower than in the model with non-resilient TSA abutment (maximum stress value of 28.9 MPa). Application of the resilient TSA abutment results in more equal distribution of stress and deformations in the bone tissue under vertical forces. These values are many times lower than in the model with the non-resilient abutment.

  12. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    Science.gov (United States)

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  13. Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

    Directory of Open Access Journals (Sweden)

    Vahideh Nazari

    2017-01-01

    Full Text Available Objectives: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS. The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs with excessive crown height, fabricated from three different materials.Materials and Methods: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr, and polyetheretherketone (PEEK (n=10. After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05.Results: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001. The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively.Conclusions: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions in the molar region with excessive CHS.Keywords: Dental Implants; Polyetheretherketone; Zirconium oxide; Dental Restoration Failure; Dental Porcelain

  14. Ptosis as partial oculomotor nerve palsy due to compression by infundibular dilatation of posterior communicating artery, visualized with three-dimensional computer graphics: case report.

    Science.gov (United States)

    Fukushima, Yuta; Imai, Hideaki; Yoshino, Masanori; Kin, Taichi; Takasago, Megumi; Saito, Kuniaki; Nakatomi, Hirofumi; Saito, Nobuhito

    2014-01-01

    Oculomotor nerve palsy (ONP) due to internal carotid-posterior communicating artery (PcomA) aneurysm generally manifests as partial nerve palsy including pupillary dysfunction. In contrast, infundibular dilatation (ID) of the PcomA has no pathogenic significance, and mechanical compression of the cranial nerve is extremely rare. We describe a 60-year-old woman who presented with progressive ptosis due to mechanical compression of the oculomotor nerve by an ID of the PcomA. Three-dimensional computer graphics (3DCG) accurately visualized the mechanical compression by the ID, and her ptosis was improved after clipping of the ID. ID of the PcomA may cause ONP by mechanical compression and is treatable surgically. 3DCG are effective for the diagnosis and preoperative simulation.

  15. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface

    DEFF Research Database (Denmark)

    Gotfredsen, K; Karlsson, U

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate whether there was a difference between machined and TiO(2)-blasted implants regarding survival rate and marginal bone loss during a 5-year observation period. MATERIALS AND METHODS: A total of 133 implants (Astra Tech Dental Implants; Astra Tech...... AB, Mölndal, Sweden) were placed in 50 patients at 6 centers in 4 Scandinavian countries. Forty-eight implants were installed in the maxilla and 85 implants in the mandible. A randomization and a stratification were done, so that each fixed partial prosthesis was supported by at least 1 machined...... and 1 TiO(2)-blasted implant. The implant-supported fixed partial prostheses (ISFPP) were fabricated within 2 months after postoperative healing. A total of 52 ISFPP (17 maxillary, 35 mandibular) were inserted. The patients were clinically examined once a year for 5 years. At the annual follow...

  16. Axial Changes of Catalyst Structure and Temperature in a Fixed-Bed Microreactor During Noble Metal Catalysed Partial Oxidation of Methane

    DEFF Research Database (Denmark)

    Hannemann, S.; Grunwaldt, Jan-Dierk; Kimmerle, B.

    2009-01-01

    The catalytic partial oxidation of methane (CPO) over flame-made 2.5%Rh-2.5%Pt/Al2O3 and 2.5%Rh/Al2O3 in 6%CH4/3%O-2/He shows the potential of in situ studies using miniaturized fixed-bed reactors, the importance of spatially resolved studies and its combination with infrared thermography and on-...

  17. Prosthetic rehabilitation of mandibular defects with fixed-removable partial denture prosthesis using precision attachment: A twin case report

    Directory of Open Access Journals (Sweden)

    Vimal Kantilal Munot

    2017-01-01

    Full Text Available The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  18. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report.

    Science.gov (United States)

    Munot, Vimal Kantilal; Nayakar, Ramesh P; Patil, Raghunath

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  19. Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: Up-to ten-year results.

    Science.gov (United States)

    Ioannidis, Alexis; Bindl, Andreas

    2016-04-01

    Only a few studies exist, which assess the clinical long-term behavior of all-ceramic FDPs in the posterior region. The aim of the present prospective clinical study was to evaluate the clinical performance of posterior three-unit FDPs manufactured from Y-TZP after a service period up to 10 years. 55 patients received 59 three-unit FDPs in the posterior region of the maxilla or mandible. Abutment teeth were prepared and full-arch impressions were taken. Definitive casts were fabricated and optically scanned. Frameworks were fabricated with computer-aided design (CAD) and manufacturing (CAM) technology. Y-TZP frameworks were veneered and adhesively luted to the abutment teeth. Baseline and follow-up examinations (service time: ≥ 48 months) were recorded by applying modified United States Public Health Services (USPHS) rating criteria. Cumulative survival rate was analyzed with Kaplan-Meier. Percentage of biological and technical complication was calculated. Fifty-three patients with 57 FDPs attended the last follow-up visit and a mean observation period of the remaining was 6.3 ± 1.9 years was calculated. Biological complications occurred in 17.5%, technical complications in 28% of the FDPs. The 10-year cumulative survival rate amounted 85.0%. Three FDPs failed to survive, two due to a root fracture of the abutment tooth and one due to secondary caries. Three-unit FDPs made from Y-TZP, veneered with ceramic offer a treatment option with a high rate of chipping. However, the manufacturing processes nowadays are modified in order to avoid this complication. The results of the present investigation suggest that three-unit Y-TZP posterior FDPs may are a possible treatment option. However, a high rate of chipping can be expected. Copyright © 2016. Published by Elsevier Ltd.

  20. Two-unit cantilevered resin-bonded fixed partial denture as a substitute for a prosthodontic-orthodontic treatment plan: a 5-year case report.

    Science.gov (United States)

    Emami, Elham; St-Georges, Annie; de Grandmont, Pierre

    2012-01-01

    In this case report, we describe the successful long-term treatment of a patient with dental agenesis. The initial treatment plan included an orthodontic phase to provide adequate space for replacing missing lateral incisors with implants. However, because of some complications encountered after 2 years of orthodontic treatment, a revised treatment plan was considered to achieve functional and esthetic goals. The patient was completely satisfied 5 years after being treated with two 2-unit cantilevered resin-bonded fixed partial dentures supported by the cuspids. This conservative treatment plan was cost-effective without having any significant biological cost.

  1. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array-Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique.

    Science.gov (United States)

    Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue

    2017-06-24

    With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  2. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array−Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique

    Directory of Open Access Journals (Sweden)

    Chen Yang

    2017-06-01

    Full Text Available With the development of satellite load technology and very large scale integrated (VLSI circuit technology, onboard real-time synthetic aperture radar (SAR imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT, which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array−application-specific integrated circuit (FPGA-ASIC hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  3. Three-year treatment outcomes with three brands of implants placed in the posterior maxilla and mandible of partially edentulous patients

    NARCIS (Netherlands)

    Ozkan, Yasar; Ozcan, Mutlu; Akoglu, Burcin; Ucankale, Mert; Kulak-Ozkan, Yasemin

    Statement of problem. Survival rates of implants in posterior regions vary among clinical studies. Problems occur more often in the posterior segment of the maxilla due to proximity of the maxillary sinus and reduced quality or quantity of alveolar bone. Purpose. This clinical study evaluated the

  4. Ten-year survival rates of teeth adjacent to treated and untreated posterior bounded edentulous spaces.

    Science.gov (United States)

    Aquilino, S A; Shugars, D A; Bader, J D; White, B A

    2001-05-01

    Failure to replace a single missing posterior tooth may lead to a variety of dental problems, which may ultimately result in tooth loss. However, little is known about the fate of the adjacent teeth if a missing posterior tooth is not replaced. This retrospective study evaluated the survival of teeth adjacent to treated and untreated posterior bounded edentulous spaces. Data were obtained from electronic treatment records from the Kaiser Permanente Dental Care Program, Portland, Ore. A final sample of 317 patients who met the study inclusion criteria was identified. Each bounded edentulous space was placed in 1 of 3 treatment categories: untreated, restored with a fixed partial denture, or restored with a removable partial denture. Subsequent treatment and the status of the teeth adjacent to the bounded edentulous space were followed through December 1999. Ten-year Kaplan-Meier survival estimates were generated for each treatment group, and differences in survival were evaluated with the log-rank chi-square test (alpha=.05). There was a significant difference in survival among the 3 treatment categories (P=.005). Spaces restored with a fixed partial denture had longer 10-year survival estimates (92%) than those that remained untreated (81%). Spaces restored with a removable partial denture had the poorest 10-year survival rate (56%). Under the conditions and selection bias associated with this retrospective study, the survival of teeth adjacent to a single posterior edentulous space was negatively associated with removable partial denture placement compared with no treatment or the use of a fixed partial denture.

  5. The total occlusal convergence of the abutment of a partial fixed dental prosthesis: A definition and a clinical technique for its assessment

    Science.gov (United States)

    Mamoun, John S.

    2013-01-01

    The abutment(s) of a partial fixed dental prosthesis (PFDP) should have a minimal total occlusal convergence (TOC), also called a taper, in order to ensure adequate retention of a PFDP that will be made for the abutment(s), given the height of the abutment(s). This article reviews the concept of PFDP abutment TOC and presents an alternative definition of what TOC is, defining it as the extent to which the shape of an abutment differs from an ideal cylinder shape of an abutment. This article also reviews experimental results concerning what is the ideal TOC in degrees and explores clinical techniques of estimating the TOC of a crown abutment. The author suggests that Dentists use high magnification loupes (×6-8 magnification or greater) or a surgical operating microscope when preparing crown abutments, to facilitate creating a minimum abutment TOC. PMID:24932130

  6. Interdisciplinary approach to enhance the esthetics of maxillary anterior region using soft- and hard-tissue ridge augmentation in conjunction with a fixed partial prosthesis.

    Science.gov (United States)

    Khetarpal, Shaleen; Chouksey, Ajay; Bele, Anand; Vishnoi, Rahul

    2018-01-01

    Favorable esthetics is one of the most important treatment outcomes in dentistry, and to achieve this, interdisciplinary approaches are often required. Ridge deficiencies can be corrected for both, soft- and hard-tissue discrepancies. To overcome such defects, not only a variety of prosthetic options are at our disposal but also several periodontal plastic surgical techniques are available as well. Various techniques have been described and revised, over the year to correct ridge defects. For enhancing soft-tissue contours in the anterior region, the subepithelial connective tissue graft is the treatment of choice. A combination of alloplastic bone graft in adjunct to connective tissue graft optimizes ridge augmentation and minimizes defects. The present case report describes the use of vascular interpositional connective tissue graft in combination with alloplastic bone graft for correction of Seibert's Class III ridge deficiency followed by a fixed partial prosthesis to achieve a better esthetic outcome.

  7. Interdisciplinary approach to enhance the esthetics of maxillary anterior region using soft- and hard-tissue ridge augmentation in conjunction with a fixed partial prosthesis

    Directory of Open Access Journals (Sweden)

    Shaleen Khetarpal

    2018-01-01

    Full Text Available Favorable esthetics is one of the most important treatment outcomes in dentistry, and to achieve this, interdisciplinary approaches are often required. Ridge deficiencies can be corrected for both, soft- and hard-tissue discrepancies. To overcome such defects, not only a variety of prosthetic options are at our disposal but also several periodontal plastic surgical techniques are available as well. Various techniques have been described and revised, over the year to correct ridge defects. For enhancing soft-tissue contours in the anterior region, the subepithelial connective tissue graft is the treatment of choice. A combination of alloplastic bone graft in adjunct to connective tissue graft optimizes ridge augmentation and minimizes defects. The present case report describes the use of vascular interpositional connective tissue graft in combination with alloplastic bone graft for correction of Seibert's Class III ridge deficiency followed by a fixed partial prosthesis to achieve a better esthetic outcome.

  8. Experimental study on heat transfer enhancement of laminar ferrofluid flow in horizontal tube partially filled porous media under fixed parallel magnet bars

    Energy Technology Data Exchange (ETDEWEB)

    Sheikhnejad, Yahya; Hosseini, Reza, E-mail: hoseinir@aut.ac.ir; Saffar Avval, Majid

    2017-02-15

    In this study, steady state laminar ferroconvection through circular horizontal tube partially filled with porous media under constant heat flux is experimentally investigated. Transverse magnetic fields were applied on ferrofluid flow by two fixed parallel magnet bar positioned on a certain distance from beginning of the test section. The results show promising notable enhancement in heat transfer as a consequence of partially filled porous media and magnetic field, up to 2.2 and 1.4 fold enhancement were observed in heat transfer coefficient respectively. It was found that presence of both porous media and magnetic field simultaneously can highly improve heat transfer up to 2.4 fold. Porous media of course plays a major role in this configuration. Virtually, application of Magnetic field and porous media also insert higher pressure loss along the pipe which again porous media contribution is higher that magnetic field. - Highlights: • Porous media can improve the coefficient of heat transfer up to 2.2 fold. • Both porous media and Nano particles have undesired pressure drop effect. • Application of both porous media and magnetic field in ferrofluid flow will result in significant enhancement in heat transfer up to 2.4 fold. • Magnet bar effect is mainly restricted to approximately one fourth of the test section. • Diluted Ferrofluids 2%, results in over 1.4 fold enhancement in heat transfer coefficient.

  9. Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.

    Science.gov (United States)

    Heinemann, Friedhelm; Grufferty, Brendan; Papavasiliou, George; Dominiak, Marzena; García, Jaime Jiménez; Trullenque-Eriksson, Anna; Esposito, Marco

    2016-01-01

    To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed

  10. Three-unit posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with layered and milled (CAD-on) veneering ceramics: 1-year follow-up of a randomized controlled clinical trial.

    Science.gov (United States)

    Grohmann, Philipp; Bindl, Andreas; Hämmerle, Christoph; Mehl, Albert; Sailer, Irena

    2015-01-01

    The aim of this multicenter randomized controlled clinical trial was to test posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with a computer-aided design/computer- assisted manufacture (CAD/CAM) lithium disilicate veneering ceramic (CAD-on) and manually layered zirconia veneering ceramic with respect to survival of the FDPs, and technical and biologic outcomes. Sixty patients in need of one posterior three-unit FDP were included. The zirconia frameworks were produced with a CAD/CAM system (Cerec inLab 3D/Cerec inEOS inLab). Thirty FDPs were veneered with a CAD/CAM lithium disilicate veneering ceramic (Cad-on) (test) and 30 were veneered with a layered zirconia veneering ceramic (control). For the clinical evaluation at baseline, 6, and 12 months, the United States Public Health Service (USPHS) criteria were used. The biologic outcome was judged by comparing the plaque control record (PCR), bleeding on probing (BOP), and probing pocket depth (PPD). Data were statistically analyzed. Fifty-six patients were examined at a mean follow-up of 13.9 months. At the 1-year follow-up the survival rate was 100% in the test and in the control group. No significant differences of the technical outcomes occurred. Major chipping occurred in the control group (n = 3) and predominantly minor chipping in the test group (minor n = 2, major n = 1). No biologic problems or differences were found. Both types of zirconia-ceramic FDPs exhibited very good clinical outcomes without differences between groups. Chipping occurred in both types of FDPs at small amounts, yet the extension of the chippings differed. The test FDPs predominantly exhibited minor chipping, the control FDPs major chipping.

  11. Variations of posterior vitreous detachment

    OpenAIRE

    Kakehashi, A.; Kado, M.; Akiba, J.; Hirokawa, H.

    1997-01-01

    AIMS—To identify variations in posterior vitreous detachment (PVD) and establish a clinical classification system for PVD.
METHODS—400 consecutive eyes were examined using biomicroscopy and vitreous photography and classified the PVD variations—complete PVD with collapse, complete PVD without collapse, partial PVD with thickened posterior vitreous cortex (TPVC), or partial PVD without TPVC.
RESULTS—In each PVD type, the most frequently seen ocular pathologies were as follows: in complete PVD ...

  12. Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study.

    Science.gov (United States)

    Marquardt, Pascal; Strub, Jörg Rudolf

    2006-04-01

    The aim of this prospective clinical study was to evaluate the survival rates of IPS Empress 2 (Ivoclar Vivadent) all-ceramic crowns and fixed partial dentures (FPDs) after an observation period of up to 5 years. Forty-three patients (19 women and 24 men) were included in this study. The patients were treated with a total of 58 adhesive bonded IPS Empress 2 restorations. A total of 27 single crowns were placed on molars and premolars, and 31 three-unit FPDs were placed in the anterior and premolar regions. Clinical follow-up examinations took place at 6, 12, 24, 36, 48, and 60 months after insertion. Statistical analysis of the data was calculated using the Kaplan-Meier method. Results of the 50-month analysis (interquartile range, 33 to 61 months) showed that the survival rate was 100% for crowns and 70% for FPDs. Six failures that occurred exclusively in the three-unit FPDs were observed. Framework fractures were recorded in three FPD units where the connector dimensions did not meet the manufacturer specifications. Only one FPD exhibited an irreparable partial veneer fracture, and 2 FPDs showed evidence of biologic failures. The accuracy of fit and esthetic parameters were clinically satisfactory for crowns and FPDs. The results of this 5-year clinical evaluation suggest that IPS Empress 2 ceramic is an appropriate material for the fabrication of single crowns. Because of the reduced survival rates, strict conditions should be considered before the use of IPS Empress 2 material for the fabrication of three-unit FPDs.

  13. Spondylolisthesis and Posterior Instability

    International Nuclear Information System (INIS)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D.; Simons, P.; Kuchta, J.

    2009-01-01

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI

  14. Spondylolisthesis and Posterior Instability

    Energy Technology Data Exchange (ETDEWEB)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D. (Privatpraxis fuer Upright MRT, Koeln (Germany)); Simons, P.; Kuchta, J. (Media Park Klinik, Koeln (Germany))

    2009-04-15

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI.

  15. Transition from failing dentition to full-arch fixed implant-supported prosthesis with a staged approach using removable partial dentures: a case series.

    Science.gov (United States)

    Cortes, Arthur Rodriguez Gonzalez; Cortes, Djalma Nogueira; No-Cortes, Juliana; Arita, Emiko Saito

    2014-06-01

    The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full-arch fixed implant-supported prosthesis may be inserted. Eight patients, who had undergone maxillary full-arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow-up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line. © 2013 by the American College of Prosthodontists.

  16. Achieve efficient nitrogen removal from real sewage in a plug-flow integrated fixed-film activated sludge (IFAS) reactor via partial nitritation/anammox pathway.

    Science.gov (United States)

    Yang, Yandong; Zhang, Liang; Cheng, Jun; Zhang, Shujun; Li, Baikun; Peng, Yongzhen

    2017-09-01

    This study tested the feasibility of plug-flow integrated fixed-film activated sludge (IFAS) reactor in applying sewage partial nitritation/anammox (PN/A) process. The IFAS reactor was fed with real pre-treated sewage (C/N ratio=1.3) and operated for 200days. High nitrogen removal efficiency of 82% was achieved with nitrogen removal rates of 0.097±0.019kgN/(m 3 ·d). Therefore, plug-flow IFAS reactor could be an alternative to applying sewage PN/A process. Besides, it was found that the stability of sewage PN/A process was significantly affected by residual ammonium. Nitrate accumulated in effluent and PN/A performance deteriorated when residual ammonium was below 1mg/L. On the contrary, long-term stable PN/A operation was achieved when residual ammonium was over 3mg/L. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Avaliação da inclinação dentoalveolar e dimensões do arco superior em mordidas cruzadas posteriores tratadas com aparelho expansor removível e fixo Evaluation of the dentoalveolar inclination and upper arch dimensions in posterior cross bite treated with removable and fixed expander appliances

    Directory of Open Access Journals (Sweden)

    Ary dos Santos-Pinto

    2006-08-01

    Full Text Available OBJETIVO: avaliar as diferenças produzidas nas dimensões e forma de arco pelos tratamentos com aparelho expansor fixo tipo Hyrax e aparelho expansor removível tipo Placa de Hawley com parafuso expansor palatino centralizado. MATERIAL E MÉTODOS: foram selecionados modelos de estudo iniciais e finais de 31 crianças portadoras de mordida cruzada posterior, de ambos os gêneros, de origem étnica diversa e na fase da dentadura mista, tratadas nos cursos de Graduação e Pós-Graduação em Ortodontia do Departamento de Clínica Infantil da Faculdade de Odontologia de Araraquara - UNESP. Destas crianças, 15 foram tratadas com uso do aparelho expansor fixo tipo Hyrax e as demais 16 crianças foram tratados com expansão rápida da maxila efetuada com o aparelho expansor fixo. Foram realizadas medidas das distâncias intercaninos e intermolares, da inclinação do processo alveolar e inclinação dentária nas imagens escaneadas do arco superior e do contorno do palato, obtido com auxílio de um template ajustável e do programa de análises Radiocef Studio. RESULTADOS E CONCLUSÕES: os resultados indicam uma mudança significante nas distâncias intercaninos e intermolares em ambos os grupos e uma inclinação dentária e do processo alveolar para vestibular significante no grupo tratado com o aparelho expansor fixo. A expansão conseguida pelo aparelho expansor fixo foi aproximadamente o dobro da promovida pelo aparelho expansor removível.AIM: to evaluate the differences of arch dimension and arch form obtained by treating the posterior cross-bite with the fixed expander appliance Hyrax and with the removable expander type Hawley plate with centralized screw. METHODS: initial and final study models of thirty-one children in the mixed dentition phase, of both genders and same ethnic origin treated in the Araraquara School of Dentistry, UNESP, São Paulo, Brazil - undergraduate and graduation Orthodontic courses. Fifteen children were treated

  18. Influence of artificial aging on the load-bearing capability of straight or angulated zirconia abutments in implant/tooth-supported fixed partial dentures.

    Science.gov (United States)

    Nothdurft, Frank P; Doppler, Klaus E; Erdelt, Kurt J; Knauber, Andreas W; Pospiech, Peter R

    2010-01-01

    The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments used in ZirDesign (Astra Tech) implant/tooth-supported fixed partial dentures (FPDs) in the maxilla. Four different test groups (n = 8) representing anterior implant/tooth-supported FPDs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (maxillary left central incisor) from a prosthetic point of view, which allowed for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position that required an angulated (20-degree) abutment. OsseoSpeed implants (4.5 3 13 mm, Astra Tech) as well as metal tooth analogs (maxillary right lateral incisor) with simulated periodontal mobility were mounted in polymethyl methacrylate. The FPDs (chromium-cobalt alloy) were cemented with glass ionomer. Groups 2 and 4 were thermomechanically loaded and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples survived thermomechanical loading. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the straight abutments or the angulated abutments. The restorations that used angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1: 209.13 ± 39.11 N; group 2: 233.63 ± 30.68 N; group 3: 324.62 ± 108.07 N; group 4: 361.75 ± 73.82 N). This difference in load-bearing performance was statistically significant, both with and without artificial aging. All abutment fractures occurred below the implant shoulder. Compensation for angulated implant positions with an angulated zirconia abutment is possible without reducing the load-bearing capacity of implant/tooth-supported anterior FPDs.

  19. IPS-Empress II inlay-retained fixed partial denture reinforced with zirconia bar: three-dimensional finite element and in-vitro studies.

    Science.gov (United States)

    Kermanshah, Hamid; Geramy, Allahyar; Ebrahimi, Shahram Farzin; Bitaraf, Tahereh

    2012-12-01

    This study evaluated von Mises stress distribution, flexural strength and interface micrographs of IPS-Empress II (IPS) inlay-retained fixed partial dentures (IRFPD) reinforced with Zirconia bars (Zb). In the Finite element analysis, six three-dimensional models of IRFPD were designed using Solid Works 2006. Five models were reinforced with different Zb and a model without Zb was considered as a control. The bridges were loaded by 200 and 500 N forces at the middle of the pontic on the occlusal surface. Subsequently, von Mises stress and displacement of the models were evaluated along a defined path. In the experimental part, 21 bar shape specimens were fabricated from lithium disilicate and zirconia ceramic in three different designs. The zirconia-IPS interfaces and the fractured surfaces of flexural test were observed using SEM. In the connector area, von Mises stress and displacement of the models with Zb under a load of 500 N were decreased compared to the model without the Zb; however, this difference was not considerable at a load of 200 N. In the mesial connector, Von Mises stress and displacement was decreased from 12.5 Mpa for the control model tested at 500 N to 7.0 Mpa for the model with Zb and from 0.0050-0.0041 mm, respectively. SEM analyses showed that, before fracture, interfacial gaps were not observed along the interfaces, but initiated cracks propagated along the interfaces after flexural loading. IPS IRFPD reinforced by Zb can tolerate higher stresses while still functioning effectively and the interfaces may have desirable adaption.

  20. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study.

    Science.gov (United States)

    Lee, Jae-In; Lee, Yoon; Kim, Yu-Lee; Cho, Hye-Won

    2016-02-01

    The 4-, 3- or even 2-implant-supported partial fixed dental prosthesis (PFDP) designs have been used to rehabilitate the anterior edentulous maxilla. The purpose of this in vitro study was to compare the stress distribution in the supporting tissues surrounding implants placed in the anterior maxilla with 5 PFDP designs. A photoelastic model of the human maxilla with an anterior edentulous region was made with photoelastic resin (PL-2; Vishay Micro-Measurements), and 6 straight implants (OsseoSpeed; Astra Tech AB) were placed in the 6 anterior tooth positions. The 5 design concepts based on implant location were as follows: model 6I: 6 implants; model 2C2CI: 4 implants (2 canines and 2 central incisors); model 2C2LI: 4 implants (2 canines and 2 lateral incisors); model 2C1CI: 3 implants (2 canines and 1 central incisor); and model 2C: 2 canines. A load of 127.4 N was applied on the cingulum of 3 teeth at a 30-degree angle to the long axis of the implant. Stresses that developed in the supporting structure were recorded photographically. The 6-implant-supported PFDP exhibited the most even and lowest distribution of stresses in all loading conditions. When the canine was loaded, the 2- or 3-implant-supported PFDP showed higher stresses around the implant at the canine position than did the 4- or 6-implant-supported PFDP. When the central incisor or lateral incisor was loaded, the two 4-implant-supported PFDPs exhibited similar levels of stresses around the implants and showed lower stresses than did the 2- or 3-implant-supported PFDP. Implant number and distribution influenced stress distribution around the implants in the anterior maxilla. With a decrease in implant number, the stresses around the implants increased. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Irreducible Traumatic Posterior Shoulder Dislocation

    Directory of Open Access Journals (Sweden)

    Blake Collier

    2017-01-01

    coracoid, marked limitation of abduction, and complete absence of external rotation with a fixed internal rotation deformity.2 Lesions commonly associated with traumatic posterior subluxation/dislocation are the reverse Hill-Sachs,3 a posterior labral detachment, glenohumeral ligament lesions,4 rotator cuff tears or posterior bony fractures.1 In order to make an accurate diagnosis it is important to obtain adequate x-ray imaging, including a “Y” view.2 Anteroposterior x-rays may show widening of the glenohumeral joint resembling a “light bulb” shape of the humeral head. However, definitive diagnosis is made by the “Y” view which shows the humeral head displaced posteriorly and no longer covering the glenoid fossa6. Irreducible acute posterior dislocation of the shoulder is extremely rare5 and only one other case has been reported in the literature.7

  2. Three-year clinical follow-up of posterior teeth restored with leucite-reinforced ips empress onlays and partial veneer crowns.

    Science.gov (United States)

    Murgueitio, Rafael; Bernal, Guillermo

    2012-07-01

    The aim of this study was to analyze the survival rate and failure mode of IPS leucite-reinforced ceramic onlays and partial veneer crowns regarding thickness under the following clinical conditions: vital versus nonvital teeth, tooth location, and type of opposing dentition. Teeth were prepared according to established guidelines for ceramic onlays and partial veneer crowns. Before cementation, the restorations were measured for occlusal thickness at the central fossa, mesial, and distal marginal ridges, and functional and nonfunctional cusps. A total of 210 ceramic restorations were cemented in 99 patients within a mean observation period of 2.9 ± 1.89 years. The mode of failure was classified and evaluated as (1) adhesive, (2) cohesive, (3) combined failure, (4) decementation, (5) tooth sensitivity, and (6) pulpal necrosis. Kaplan, log-rank, and Cox regression tests were used for statistical analysis. The failure rate was 3.33% (7/210). Increased material thickness produced less probability of failures. Vital teeth were less likely to fail than nonvital teeth. Second molars were five times more susceptible to failure than first molars. Tooth sensitivity postcementation and the type of opposing dentition were not statistically significant in this study. In this study, thickness of the restorations, tooth vitality, and location of teeth in the dental arch influenced restoration failures. © 2012 by the American College of Prosthodontists.

  3. Partial oxidation of Raffinate II and other mixtures of n-Butane and n-Butenes to maleic anhydride in a fixed-bed reactor

    OpenAIRE

    Brandstädter, Willi Michael

    2008-01-01

    The utilisation of the C4 streams of steamcrackers by converting raffinate II to maleic anhydride was studied. The oxidation reactions were investigated in a laboratory-scale fixed-bed reactor to determine reaction kinetics. The effects of pore diffusional resistance were investigated and explained. A two-dimensional pseudo-homogeneous reactor model was used for the simulation of a production-scale fixed-bed reactor. A flow scheme of the reactor section including a recycle was proposed.

  4. Validation of the "Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)" scale for wearers of implant-supported fixed partial dentures.

    Science.gov (United States)

    Castillo-Oyagüe, Raquel; Perea, Carmen; Suárez-García, María-Jesús; Río, Jaime Del; Lynch, Christopher D; Preciado, Arelis

    2016-12-01

    To validate the 'Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)' questionnaire for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-supported fixed partial denture (FPD) wearers. 107 patients were assigned to: Group 1 (HP; n=37): fixed-detachable hybrid prostheses (control); Group 2 (C-PD, n=35): cemented partial dentures; and Group 3 (S-PD, n=35): screwed partial dentures. Patients answered the QoLFAST-10 and the Oral Health Impact Profile (OHIP-14sp) scales. Information on global oral satisfaction, socio-demographic, prosthetic, and clinical data was gathered. The psychometric capacity of the QoLFAST-10 was investigated. The correlations between both indices were explored by the Spearman's rank test. The effect of the study variables on the OHRQoL was evaluated by descriptive and non-parametric probes (α=0.05). The QoLFAST-10 was reliable and valid for implant-supported FPD wearers, who attained comparable results regardless of the connection system being cement or screws. Both fixed partial groups demonstrated significantly better social, functional, and total satisfaction than did HP wearers with this index. All groups revealed similar aesthetic-related well-being and consciousness about the importance of health-behavioural habits. Several study variables modulated the QoLFAST-10 scores. Hybrid prostheses represent the least predictable treatment option, while cemented and screwed FPDs supplied equal OHRQoL as estimated by the QoLFAST-10 scale. The selection of cemented or screwed FPDs should mainly rely on clinical factors, since no differences in patient satisfaction may be expected between both types of implant rehabilitations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Posterior Urethral Strictures

    Directory of Open Access Journals (Sweden)

    Joel Gelman

    2015-01-01

    Full Text Available Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty.

  6. Posterior Urethral Strictures

    Science.gov (United States)

    Gelman, Joel; Wisenbaugh, Eric S.

    2015-01-01

    Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect) after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty. PMID:26691883

  7. Treatment of a partially thrombosed giant aneurysm of the vertebral artery by aneurysm trapping and direct vertebral artery-posterior inferior cerebellar artery end-to-end anastomosis: technical case report.

    Science.gov (United States)

    Benes, Ludwig; Kappus, Christoph; Sure, Ulrich; Bertalanffy, Helmut

    2006-07-01

    The purpose of this article is to focus for the first time on the operative management of a direct vertebral artery (VA)-posterior inferior cerebellar artery (PICA) end-to-end anastomosis in a partially thrombosed giant VA-PICA-complex aneurysm and to underline its usefulness as an additional treatment option. The operative technique of a direct VA-PICA end-to-end anatomosis is described in detail. The VA was entering the large aneurysm sack. Distally, the PICA originated from the aneurysm sack-VA-complex. The donor and recipient vessel were cut close to the aneurysm. Whereas the VA was cut in a straight manner, the PICA was cut at an oblique 45-degree angle to enlarge the vascular end diameter. Vessel ends were flushed with heparinized saline and sutured. The thrombotic material inside the aneurysm sack was removed and the distal VA clipped, leaving the anterior spinal artery and brainstem perforators free. The patient regained consciousness without additional morbidity. Magnetic resonance imaging scans revealed a completely decompressed brainstem without infarction. The postoperative angiograms demonstrated a good filling of the anastomosed PICA. Despite the caliber mistmatch of these two vessels the direct VA-PICA end-to-end anastomosis provides an accurate alternative in addition to other anastomoses and bypass techniques, when donor and recipient vessels are suitable and medullary perforators do not have to be disrupted.

  8. Bilateral arcuate foramen associated with partial defect of the posterior arch of the atlas in a medieval skeleton: case report and review of the literature. Looking backward to go forward.

    Science.gov (United States)

    Travan, Luciana; Saccheri, Paola; Sabbadini, Gastone; Crivellato, Enrico

    2011-08-01

    We observed a complex atlas (C1) dysmorphism in a human medieval skeleton dug up from the sixth to the seventh century necropolis located in the north-eastern Italy. We analyzed such a dysmorphism in the light of pertinent literature and discussed the functional and clinical implications related to this type of C1 structural malformation. Macroscopical and CT-SCAN examinations of the atlas were carried out. Bone findings consisted of partial aplasia of the posterior arch of the C1 accompanied by a bilateral arcuate foramen. In addition, the spinous processes of C7 and T1 were found to be bifid. Although such abnormalities are supposed to be clinically inconspicuous, yet they may become challenging or even dangerous in the context of trauma. They may even complicate specific diagnostic or surgical procedures. In addition, they may cause a great number of symptoms, ranging from headache and neck pain to loss of postural muscle tone and consciousness, due to the close and complex relationship of bone structures with nerves, blood vessels, muscles, and ligaments. As a result, radiologists, clinicians, surgeons, and chiropractors should consider in their clinical reasoning the possibility that atlas dysmorphisms may occur.

  9. Classification of posterior vitreous detachment

    Science.gov (United States)

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2014-01-01

    Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography (OCT). By biomicroscopy, the vitreous condition is determined based on the presence or absence of a PVD. The PVD then is classified as either a complete posterior vitreous detachment (C-PVD) or a partial posterior vitreous detachment (P-PVD). A C-PVD is further divided into a C-PVD with collapse and a C-PVD without collapse, while a P-PVD is divided into a P-PVD with shrinkage of the posterior hyaloid membrane (P-PVD with shrinkage) and a P-PVD without shrinkage of the posterior hyaloid membrane (P-PVD without shrinkage). A P-PVD without shrinkage has a subtype characterized by vitreous gel attachment through the premacular hole in a posterior hyaloid membrane to the macula (P-PVD without shrinkage [M]). By OCT, a shallow PVD is classified as the absence of a shallow PVD or as a shallow PVD. A shallow PVD is then subclassified as a shallow PVD without shrinkage of the posterior vitreous cortex, a shallow PVD with shrinkage of the posterior vitreous cortex, and a peripheral shallow PVD. A shallow PVD without shrinkage of the posterior vitreous cortex has two subtypes: an age-related shallow PVD and a perifoveal PVD associated with a macular hole. PMID:24376338

  10. Fixed Points

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 5. Fixed Points - From Russia with Love - A Primer of Fixed Point Theory. A K Vijaykumar. Book Review Volume 5 Issue 5 May 2000 pp 101-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  11. Vermian agenesis without posterior fossa cyst

    International Nuclear Information System (INIS)

    Adamsbaum, C.; Moreau, V.; Bulteau, C.; Burstyn, J.; Lair Milan, F.; Kalifa, G.

    1994-01-01

    We report 11 cases of vermian partial agenesis without posterior fossa cyst or hemispheric abnormalities. Characteristic MR signs were: absence of the posterior lobe, hypoplasia of the anterior lobe, a narrow sagittal cleft separating the hemispheres (''buttocks sign'') and fourth ventricle deformity. The main clinical signs were complex oculomotor dysfunction and developmental delay. None of the patients had respiratory symptoms. Consideration is given to the relationship between Joubert syndrome and this entity as well as to embroyological data. (orig.)

  12. Fix 40!

    Index Scriptorium Estoniae

    2008-01-01

    Ansambel Fix peab 13. detsembril Tallinnas Saku Suurhallis oma 40. sünnipäeva. Kontserdi erikülaline on ansambel Apelsin, kaastegevad Jassi Zahharov ja HaleBopp Singers. Õhtut juhib Tarmo Leinatamm

  13. Orthodontic treatment for posterior crossbites.

    Science.gov (United States)

    Agostino, Paola; Ugolini, Alessandro; Signori, Alessio; Silvestrini-Biavati, Armando; Harrison, Jayne E; Riley, Philip

    2014-08-08

    A posterior crossbite occurs when the top back teeth bite inside the bottom back teeth. When it affects one side of the mouth, the lower jaw may have to move to one side to allow the back teeth to meet together. Several treatments have been recommended to correct this problem. Some treatments widen the upper teeth while others are directed at treating the cause of the posterior crossbite (e.g. breathing problems or sucking habits). Most treatments have been used at each stage of dental development. This is an update of a Cochrane review first published in 2001. To assess the effects of orthodontic treatment for posterior crossbites. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 21 January 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 1), MEDLINE via OVID (1946 to 21 January 2014), and EMBASE via OVID (1980 to 21 January 2014). We searched the US National Institutes of Health Trials Register and the World Health Organization (WHO) Clinical Trials Registry Platform for ongoing trials. We placed no restrictions on the language or date of publication when searching the electronic databases. Randomised controlled trials (RCTs) of orthodontic treatment for posterior crossbites in children and adults. Two review authors, independently and in duplicate, screened the results of the electronic searches, and extracted data and assessed the risk of bias of the included studies. We attempted to contact the first named authors of the included studies for missing data and for clarification. We used risk ratios (RR) and 95% confidence intervals (CIs) to summarise dichotomous (event) data, and mean differences (MD) with 95% CIs to summarise continuous data. We performed meta-analyses using fixed-effect models (we would have used random-effects models if we had included four or more studies in a meta-analysis) when comparisons and outcomes were sufficiently similar. We

  14. Single and multi-component adsorption of salicylic acid, clofibric acid, carbamazepine and caffeine from water onto transition metal modified and partially calcined inorganic-organic pillared clay fixed beds.

    Science.gov (United States)

    Cabrera-Lafaurie, Wilman A; Román, Félix R; Hernández-Maldonado, Arturo J

    2015-01-23

    Fixed-beds of transition metal (Co(2+), Ni(2+) or Cu(2+)) inorganic-organic pillared clays (IOCs) were prepared to study single- and multi-component non-equilibrium adsorption of a set of pharmaceutical and personal care products (PPCPs: salicylic acid, clofibric acid, carbamazepine and caffeine) from water. Adsorption capacities for single components revealed that the copper(II) IOCs have better affinity toward salicylic and clofibric acid. However, multi-component adsorption tests showed a considerable decrease in adsorption capacity for the acids and an unusual selectivity toward carbamazepine depending on the transition metal. This was attributed to a combination of competition between PPCPs for adsorption sites, adsorbate-adsorbate interactions, and plausible pore blocking caused by carbamazepine. The cobalt(II) IOC bed that was partially calcined to fractionate the surfactant moiety showcased the best selectivity toward caffeine, even during multi-component adsorption. This was due to a combination of a mildly hydrophobic surface and interaction between the PPCP and cobalt(II). In general, the tests suggest that these IOCs may be a potential solution for the removal of PPCPs if employed in a layered-bed configuration, to take care of families of adsorbates in a sequence that would produce sharpened concentration wavefronts. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Influence of Connector Width on the Stress Distribution of Posterior Bridges under Loading

    Directory of Open Access Journals (Sweden)

    A. Azary

    2011-06-01

    Full Text Available Objective: In all ceramic fixed partial dentures the connector area is a common fracture location. The survival time of three-unit fixed partial dentures may be improved by altering the connector design in regions of maximum tension. The purpose of this study was to determine the effect of buccolingual increase of the connector width on the stress distribution in posterior fixed partial dentures made of IPS Empress 2. To simulate the anatomical condition, we used three-dimensional finite element analysis to generate.Materials and Methods: Three models of three-unit bridges replacing the first molar were prepared. The buccolingual connector width varied from 3.0 to 5.0 mm. Bridges were vertically loaded with 600 N at one point on the central fossa of the pontic, at 12 points along the cusp-fossa contact (50 N each, or at eight points along the cusp-marginal ridge contact (75 N each. Alternatively, a load of 225 N was applied at a 45º angle from the lingual side.Results: Stress concentrations were observed within or near the connectors. The von Mises stress decreased by increasing connector width, regardless of whether the loading was applied vertically or at an angle.Conclusion: Within the limitations of this study, we conclude that increasing the connector width decreases the failure probability when a vertical or angled load is applied.

  16. Posterior fossa epidural hematoma

    International Nuclear Information System (INIS)

    Kushner, M.J.; Luken, M.G. III

    1983-01-01

    CT demonstrated posterior fossa epidural hematoma in three patients with head trauma in whom this diagnosis was not clinically apparent. No patient was in stupor or coma and no patient experienced a lucid interval. Only one patient had signs referable to the posterior fossa. Two patients had occipital skull fracture disclosed by plain radiographs. CT revealed a unilateral biconvex hematoma in two cases, and a bilateral hematoma with supratentorial extension in the third. All patients underwent suboccipital craniectomy and recovered. Therapeutic success in these cases was facilitated by early CT and the rapid disclosure of the unsuspected posterior fossa lesions. CT showing contiguous hematoma below and above the tentorium cerebelli after posterior head trauma is highly suggestive of epidural hematoma arising from the posterior fossa. (orig.)

  17. In Vitro Comparison of Marginal and Internal Fit of Press-on-Metal Ceramic (PoM) Restorations with Zirconium-Supported and Conventional Metal Ceramic Fixed Partial Dentures Before and After Veneering.

    Science.gov (United States)

    Varol, Seda; Kulak-Özkan, Yasemin

    2015-07-01

    To compare marginal and internal fit between 3- and 4-unit press-on-metal (PoM) ceramic, zirconia-supported, and conventional metal ceramic fixed partial dentures (FPDs) before and after veneering. Ten pieces for each 3- and 4-unit MC, IPS InLine PoM, and IPS e.max ZirCAD/Zir Press FPDs were produced. Cross-sections from silicone replicas were examined and measured with a light microscope. Occlusal, axial, intermarginal, and marginal mean adaptation scores of cross-sectioned replicas and means of measurements obtained from 4 sites were calculated independently. Mean values for molars were 78.44 ± 32.01 μm (MC), 89.84 ± 29.20 μm (PoM), and 85.17 ± 28.49 μm (Zir). Premolar values were 76.08 ± 27.92 μm (MC), 89.94 ± 23.49 μm (PoM), and 87.18 ± 28.25 μm (Zir). No difference existed between the means of 3- and 4-unit FPDs except the molar-intermarginal region. The mean value of 4-unit FPDs (93.88 ± 25.41 μm) was less than the 3-unit FPDs (103.68 ± 24.55 μm) at the molar-inter marginal region. A gap increase was observed in all sites except the molar-axio-occlusal region after veneering. According to the mean difference, gap increases at the molar-marginal, molar-intermarginal, and premolar-intermarginal regions were statistically significant. A statistical difference was found at the molar-marginal region for 4-unit MCR (p = 0.041) and 4-unit PoM FPDs (p = 0.042) before and after veneering. Gap increase after veneering of 4-unit metal ceramics at molar-intermarginal, premolar-marginal, and premolar-intermarginal regions (p = 0.020; p = 0.015; p = 0.004) was significant. The gap measurements of the IPS InLine PoM and IPS e.max ZirCAD/Zir Press groups were all clinically acceptable. No studies on marginal and internal fit in the IPS InLine PoM system have been published to date. This study should be supported with future studies. No significant increase was observed after press-veneering the IPS e.max ZirCAD frameworks with an IPS e.max ZirPress material

  18. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  19. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  20. Posterior microphthalmos pigmentary retinopathy syndrome.

    Science.gov (United States)

    Pehere, Niranjan; Jalali, Subhadra; Deshmukh, Himanshu; Kannabiran, Chitra

    2011-04-01

    Posterior Microphthalmos Pigmentary Retinopathy Syndrome (PMPRS). Posterior microphthalmos (PM) is a relatively infrequent type of microphthalmos where posterior segment is predominantly affected with normal anterior segment measurements. Herein, we report two siblings with posterior microphthalmos retinopathy syndrome with postulated autosomal recessive mode of inheritance. A 13-year-old child had PM and retinitis pigmentosa (RP) and his 7-year-old sister had PM, RP, and foveoschisis. The genetics of this syndrome and variable phenotype is discussed. Importance of being aware of posterior microphthalmos and its posterior segment associations is highlighted.

  1. Posterior Reversible Encephalopathy (PRES)

    International Nuclear Information System (INIS)

    Moron E, Fanny E; Diaz Marchan, Pedro

    2005-01-01

    The Posterior Reversible Encephalopathy Syndrome (PRES) is a clinical Syndrome composed of cephalea, alteration in vision and convulsions, usually observed in patients with sudden elevation of arterial pressure. The imagenologic evidence shows reversible vasogenic brain edema without stroke. Its location is predominantly posterior; it affects the cortex and the subcortical white matter of the occipital, parietal and temporal lobes. The treatment with antihypertensive drugs and the removing of immunosupressor medication are generally associated with complete neurological recovery; this is reflected also in the images which return to their basal condition. The untreated hypertension, on the other side, can result in a progressive defect of the autoregulation system of the central nervous system with cerebral hemorrhage, irreversible brain stroke, coma and death

  2. Robotic posterior retroperitoneal adrenalectomy.

    Science.gov (United States)

    Okoh, Alexis Kofi; Yigitbas, Hakan; Berber, Eren

    2015-09-01

    Since its initial description by Mercan et al. laparoscopic posterior retroperitoneal (PR) adrenalectomy has served as an alternaltive to the transabdominal (TL) approach for the treatment of adrenal pathologies. Robotic adrenal surgery has been reported to improve surgeon ergonomics and facilitate dissection. In patients with bilateral adrenal masses, PR adrenalectomy may be the approach of choice. We herein describe the technique, discuss its limitations and present a critical review of the current literature. © 2015 Wiley Periodicals, Inc.

  3. CT findings of posterior pararenal effusion

    International Nuclear Information System (INIS)

    Koh, Byung Hee; Cho, On Koo; Kim, Sonn Yong

    1990-01-01

    The posterior pararenal space(PPS) is a potential space between the posterior renal fascia and the transversalis fascia. We reviewed 12 cases of posterior pararenal effusion. The causes of the effusion were retroperitoneal hemorrhage due to trauma(7 cases) or rupture of renal tumor(1 case), pancreatitis(2 cases), urinoma (1 case) and amebic colitis of the cecum(1 case). The CT findings of the effusion were semilunar fluid density in the dependant portion of the PPS(9/12), partial obliteration of the PPS extending to the flank stripe(2/12), and total obliteration of the PPS extending to the anterior abdominal wall(1/12). The effusion in the ipsilateral perirenal space and thickening of the ipsilateral posterior renal fascia were combined in all cases. The effusion in the ipsilateral anterior pararenal space was associated in 11 cases of 12. The effusion in the PPS is not uncommon findings of retroperitoneal hemorrhage or effusion, but usually related with perirenal or anterior pararenal effusion with no clinical significance

  4. MR imaging of posterior cruciate ligament injuries

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Nobuyuki [Tsukuba Univ., Ibaraki (Japan). Hospital; Niitsu, Mamoru; Itai, Yuji; Sato, Motohiro; Kujiraoka, Yuka; Ikeda, Kotaro; Kanamori, Akihiro

    2001-07-01

    Posterior cruciate ligament (PCL) injuries are less frequent than anterior cruciate ligament (ACL) injuries, but are presumably more common than once thought. Thirty-nine patients with PCL injuries identified on MR images were studied. The criteria for PCL injury were complete tear, partial tear, and avulsion fracture. The approximate site of a partial tear was categorized as proximal, midsubstance, distal, or combination. Fourteen patients (35.9%) had complete tears of the PCL, 21 patients (53.8%) had partial tears, and four patients (10.3%) had avulsion fractures. A total of 12 patients (30.7%) had isolated PCL injuries, while the remaining 27 patients demonstrated evidence of other coexistent knee injuries, such as meniscal tears and ligamentous injuries. Of coexistent knee injuries, meniscal tears (18 patients, 46.2%) were most often seen. (author)

  5. MR imaging of posterior cruciate ligament injuries

    International Nuclear Information System (INIS)

    Takahashi, Nobuyuki; Niitsu, Mamoru; Itai, Yuji; Sato, Motohiro; Kujiraoka, Yuka; Ikeda, Kotaro; Kanamori, Akihiro

    2001-01-01

    Posterior cruciate ligament (PCL) injuries are less frequent than anterior cruciate ligament (ACL) injuries, but are presumably more common than once thought. Thirty-nine patients with PCL injuries identified on MR images were studied. The criteria for PCL injury were complete tear, partial tear, and avulsion fracture. The approximate site of a partial tear was categorized as proximal, midsubstance, distal, or combination. Fourteen patients (35.9%) had complete tears of the PCL, 21 patients (53.8%) had partial tears, and four patients (10.3%) had avulsion fractures. A total of 12 patients (30.7%) had isolated PCL injuries, while the remaining 27 patients demonstrated evidence of other coexistent knee injuries, such as meniscal tears and ligamentous injuries. Of coexistent knee injuries, meniscal tears (18 patients, 46.2%) were most often seen. (author)

  6. Reversible posterior leukoencephalopathy syndrome

    International Nuclear Information System (INIS)

    Lee, Eun Ja; Yu, Won Jong; Ahn, Kook Jin; Jung, So Lyung; Lee, Yeon Soo; Kim, Ji Chang; Kang, Si Won; Song, Chang Joon; Song, Soon-Young; Koo, Ja Hong; Kim, Man Deuk

    2001-01-01

    To review reversible posterior leukoencephalopathy syndrome. We reviewed 22 patients (M:F=3:19; age, 17-46 years) with the characteristic clinical and imaging features of reversible posterior leukoencephalopathy syndrome. All underwent brain MRI, and in three cases both CT and MRI were performed. In one, MRA was obtained, and in eleven, follow-up MR images were obtained. We evaluated the causes of this syndrome, its clinical manifestations, and MR findings including the locations of lesions, the presence or absence of contrast enhancement, and the changes seen at follow-up MRI. Of the 22 patients, 13 had eclampsia (six during pregnancy and seven during puerperium). Four were receiving immunosuppressive therapy (three, cyclosporine ; one, FK 506). Four suffered renal failure and one had complicated migraine. The clinical manifestations included headache (n=12), visual disturbance (n=13), seizure (n=15), focal neurologic sign (n=3), and altered mental status (n=2). Fifteen patients had hypertension and the others normotension. MRI revealed that lesions were bilateral (n=20) or unilateral (n=2). In all patients the lesion was found in the cortical and subcortical areas of the parieto-occipital lobes ; other locations were the basal ganglia (n=9), posterior temporal lobe (n=8), frontal lobe (n=5), cerebellum (n=5), pons (n=2), and thalamus (n=1). All lesions were of high signal intensity on T2-weighted images, and of iso to low intensity on T1-weighted images. One was combined with acute hematoma in the left basal ganglia. In eight of 11 patients who underwent postcontrast T1-weighted MRI, there was no definite enhancement ; in one, enhancement was mild, and in tow, patchy. CT studies showed low attenuation, and MRA revealed mild vasospasm. The symptoms of all patients improved. Follow-up MRI in nine of 11 patients depicted complete resolution of the lesions ; in two, small infarctions remained but the extent of the lesions had decreased. Reversible posterior

  7. Reversible posterior leukoencephalopathy syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ja; Yu, Won Jong; Ahn, Kook Jin; Jung, So Lyung; Lee, Yeon Soo; Kim, Ji Chang; Kang, Si Won [The Catholic Univ. of Korea, Taejon (Korea, Republic of); Song, Chang Joon [Chungnam National Univ. School of Medicine, Cheonju (Korea, Republic of); Song, Soon-Young; Koo, Ja Hong [Kwandong Univ. College of Medicine, Myungji Hospital, Seoul (Korea, Republic of); Kim, Man Deuk [College of Medicine Pochon CHA Univ., Seoul (Korea, Republic of)

    2001-10-01

    To review reversible posterior leukoencephalopathy syndrome. We reviewed 22 patients (M:F=3:19; age, 17-46 years) with the characteristic clinical and imaging features of reversible posterior leukoencephalopathy syndrome. All underwent brain MRI, and in three cases both CT and MRI were performed. In one, MRA was obtained, and in eleven, follow-up MR images were obtained. We evaluated the causes of this syndrome, its clinical manifestations, and MR findings including the locations of lesions, the presence or absence of contrast enhancement, and the changes seen at follow-up MRI. Of the 22 patients, 13 had eclampsia (six during pregnancy and seven during puerperium). Four were receiving immunosuppressive therapy (three, cyclosporine ; one, FK 506). Four suffered renal failure and one had complicated migraine. The clinical manifestations included headache (n=12), visual disturbance (n=13), seizure (n=15), focal neurologic sign (n=3), and altered mental status (n=2). Fifteen patients had hypertension and the others normotension. MRI revealed that lesions were bilateral (n=20) or unilateral (n=2). In all patients the lesion was found in the cortical and subcortical areas of the parieto-occipital lobes ; other locations were the basal ganglia (n=9), posterior temporal lobe (n=8), frontal lobe (n=5), cerebellum (n=5), pons (n=2), and thalamus (n=1). All lesions were of high signal intensity on T2-weighted images, and of iso to low intensity on T1-weighted images. One was combined with acute hematoma in the left basal ganglia. In eight of 11 patients who underwent postcontrast T1-weighted MRI, there was no definite enhancement ; in one, enhancement was mild, and in tow, patchy. CT studies showed low attenuation, and MRA revealed mild vasospasm. The symptoms of all patients improved. Follow-up MRI in nine of 11 patients depicted complete resolution of the lesions ; in two, small infarctions remained but the extent of the lesions had decreased. Reversible posterior

  8. Posterior glenoid rim deficiency in recurrent (atraumatic) posterior shoulder instability

    International Nuclear Information System (INIS)

    Weishaupt, D.; Zanetti, M.; Hodler, J.; Nyffeler, R.W.; Gerber, C.

    2000-01-01

    Objective. To assess the shape of the posterior glenoid rim in patients with recurrent (atraumatic) posterior instability.Design and patients. CT examinations of 15 shoulders with recurrent (atraumatic) posterior instability were reviewed in masked fashion with regard to abnormalities of the glenoid shape, specifically of its posterior rim. The glenoid version was also assessed. The findings were compared with the findings in 15 shoulders with recurrent anterior shoulder instability and 15 shoulders without instability. For all patients, surgical correlation was available.Results. Fourteen of the 15 (93%) shoulders with recurrent (atraumatic) posterior shoulder instability had a deficiency of the posteroinferior glenoid rim. In patients with recurrent anterior instability or stable shoulders such deficiencies were less common (60% and 73%, respectively). The craniocaudal length of the deficiencies was largest in patients with posterior instability. When a posteroinferior deficiency with a craniocaudal length of 12 mm or more was defined as abnormal, sensitivity and specificity for diagnosing recurrent (atraumatic) posterior instability were 86.7% and 83.3%, respectively. There was a statistically significant difference in glenoid version between shoulders with posterior instability and stable shoulders (P=0.01).Conclusion. Recurrent (atraumatic) posterior shoulder instability should be considered in patients with a bony deficiency of the posteroinferior glenoid rim with a craniocaudal length of more than 12 mm. (orig.)

  9. Progressive posterior cortical dysfunction

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    Full Text Available Abstract Progressive posterior cortical dysfunction (PPCD is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal and ventral (occipito-temporal pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction, complete Balint's syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right . Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD.

  10. Progressive posterior cortical dysfunction

    Science.gov (United States)

    Porto, Fábio Henrique de Gobbi; Machado, Gislaine Cristina Lopes; Morillo, Lilian Schafirovits; Brucki, Sonia Maria Dozzi

    2010-01-01

    Progressive posterior cortical dysfunction (PPCD) is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal) and ventral (occipito-temporal) pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction), complete Balint’s syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right. Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD. PMID:29213665

  11. Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs.

    Science.gov (United States)

    Gonzalo, Esther; Suárez, María J; Serrano, Benjamin; Lozano, José F L

    2009-01-01

    The purpose of this study was to compare two measurement methods for the external marginal fit of zirconia posterior fixed partial dentures (FPDs) fabricated using computer-aided design/manufacturing technology and metal-ceramic posterior FPDs fabricated using the conventional lost-wax technique. The null hypothesis was that there would be no differences between the measurement methods. Forty standardized steel specimens were prepared to receive posterior three-unit FPDs. Specimens were divided into four groups (n = 10): (1) metal-ceramic, (2) Procera Bridge Zirconia, (3) Lava AllCeramic System, and (4) Vita In-Ceram YZ 2000. All FPDs were luted with glass-ionomer cement (Ketac Cem EasyMix, 3M ESPE). Two measurement methods were used to analyze marginal fit: an image analysis (IA) program and a scanning electron microscope (SEM) (JEOL JSM-6400) with magnifications of 340 and 31,000, respectively. Marginal fit was measured at the same point on each abutment. Significant interaction was observed between measurement method and material (P = .0019). Therefore, the measurement method is not independent of the restoration material. Differences among groups were observed for IA (P = .0001) and SEM (P = .0013). Significant differences were observed for the Procera (P = .0050) and metal-ceramic (P = .0039) specimen groups when both measurement methods were evaluated separately. Accuracy of fit achieved by the four groups analyzed was within the range of clinical acceptance, yielding Procera Bridge Zirconia to have the best marginal fit using both measurement methods.

  12. Endoscopic Management of Posterior Epistaxis

    OpenAIRE

    Paul, J.; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-01-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26–50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of ...

  13. THE Economics of Match-Fixing

    OpenAIRE

    Caruso, Raul

    2007-01-01

    The phenomenon of match-fixing does constitute a constant element of sport contests. This paper presents a simple formal model in order to explain it. The intuition behind is that an asymmetry in the evaluation of the stake is the key factor leading to match-fixing. In sum, this paper considers a partial equilibrium model of contest where two asymmetric, rational and risk-neutral opponents evaluate differently a contested stake. Differently from common contest models, agents have the option ...

  14. Análisis preliminar del Límite de Potencia Eólica para grandes perturbaciones utilizando aerogeneradores de velocidad fija; Partial analysis of wind power limit for large disturbance using fixed speed wind turbine

    Directory of Open Access Journals (Sweden)

    Ariel Santos Fuentefria

    2015-04-01

    Full Text Available El Límite de Potencia Eólica (LPE es la cantidad de potencia eólica que permite un sistema sin perder la estabilidad y depende principalmente de las características de los generadores eólicos y de las características del sistema en términos de debilidad. Conocer el comportamiento del sistema en régimen transitorio es sumamente importante; entre las condiciones que generan mayores problemas se encuentran el cortocircuito en las líneas de mayor transferencia de potenciay la salida de algún generador del sistema. El LPE cambia para cada condición y conocer el LPE considerando estas condiciones permite aprovechar al máximo la energía del viento. En el presente trabajo se analiza el comportamiento de generadores eólicos de velocidad fija para diversas condiciones transitorias de la red, utilizándose el sistema de prueba de 14 nodos de la IEEE para verificar la metodología en uso para el análisis a través de simulaciones implementadas en el software libre PSAT.  The amount of wind power that allow an electric network without losing his stability as known as wind power limit. The wind power limit fundamentally depends on the wind turbine technology and the weakness level of the system. To know the system behaviors in dynamic performance having into account the worst disturbance is a very important matter, a short circuit in one of the most power transference line or the loss of a large generation unit was a large disturbance that can affect system stability. The wind power limit may change with the nature of the disturbance. To know the wind power limit considering this conditions allow use the wind at maximum level. In the present paper the behavior of fixed speed wind turbine for different fault types is analyzed, at those conditions, the wind power is increasing until the system become voltage unstable. For the analysis the IEEE 14 Bus Test Case is used. The Power System Analysis Toolbox (PSAT package is used for the simulation.

  15. Análisis preliminar del Límite de Potencia Eólica para grandes perturbaciones utilizando aerogeneradores de velocidad fija; Partial analysis of wind power limit for large disturbance using fixed speed wind turbine

    Directory of Open Access Journals (Sweden)

    Ariel Santos Fuentefria

    2014-06-01

    Full Text Available El Límite de Potencia Eólica (LPE es la cantidad de potencia eólica que permite un sistema sin perder la estabilidad y depende principalmente de las características de los generadores eólicos y de las características del sistema en términos de debilidad. Conocer el comportamiento del sistema en régimen transitorio es sumamente importante; entre las condiciones que generan mayores problemas se encuentran el cortocircuito en las líneas de mayor transferencia de potenciay la salida de algún generador del sistema. El LPE cambia para cada condición y conocer el LPE considerando estas condiciones permite aprovechar al máximo la energía del viento. En el presente trabajo se analiza el comportamiento de generadores eólicos de velocidad fija para diversas condiciones transitorias de la red, utilizándose el sistema de prueba de 14 nodos de la IEEE para verificar la metodología en uso para el análisis a través de simulaciones implementadas en el software libre PSAT The amount of wind power that allow an electric network without losing his stability as known as wind power limit. The wind power limit fundamentally depends on the wind turbine technology and the weakness level of the system. To know the system behaviors in dynamic performance having into account the worst disturbance is a very important matter, a short circuit in one of the most power transference line or the loss of a large generation unit was a large disturbance that can affect system stability. The wind power limit may change with the nature of the disturbance. To know the wind power limit considering this conditions allow use the wind at maximum level. In the present paper the behavior of fixed speed wind turbine for different fault types is analyzed, at those conditions, the wind power is increasing until the system become voltage unstable. For the analysis the IEEE 14 Bus Test Case is used. The Power System Analysis Toolbox (PSAT package is used for the simulation.

  16. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  17. Primary Posterior Mediastinum Hydatid Cyst

    International Nuclear Information System (INIS)

    Ahmed, M.; Eid, A. F.; Sheikh, M. Y.; Yiannakou, N.

    2014-01-01

    Primary posterior mediastinal hydatid cyst is a serious health problem for the Mediterranean countries. We diagnosed a case of a 46-year-old female with a primary posterior mediastinum hydatid cyst on CT and MRI. It was provisionally identified as either a hydatid cyst or bronchogenic cyst or neuroenteric cyst. CT guided aspiration with 18 gauge needle confirmed as hydatid sand. This is very rare in this population but it should be kept in mind when one is looking at any cyst in the posterior mediastinum. (author)

  18. Posterior fossa meningioma (surgical experiences)

    African Journals Online (AJOL)

    Wael M. Moussa

    2012-08-27

    Aug 27, 2012 ... of the CNS, representing about a third of brain tumors. They arise from the ... subtypes based on cell structure.1–4 In 1979, the World Health. Organization .... anterior or posterior to the internal auditory meatus), petrocli-.

  19. Flexible Thermoplastic Denture Base Materials for Aesthetical Removable Partial Denture Framework

    OpenAIRE

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-01-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated...

  20. Tripled Fixed Point in Ordered Multiplicative Metric Spaces

    Directory of Open Access Journals (Sweden)

    Laishram Shanjit

    2017-06-01

    Full Text Available In this paper, we present some triple fixed point theorems in partially ordered multiplicative metric spaces depended on another function. Our results generalise the results of [6] and [5].

  1. Fuel rod fixing system

    International Nuclear Information System (INIS)

    Christiansen, D.W.

    1982-01-01

    This is a reusable system for fixing a nuclear reactor fuel rod to a support. An interlock cap is fixed to the fuel rod and an interlock strip is fixed to the support. The interlock cap has two opposed fingers, which are shaped so that a base is formed with a body part. The interlock strip has an extension, which is shaped so that this is rigidly fixed to the body part of the base. The fingers of the interlock cap are elastic in bending. To fix it, the interlock cap is pushed longitudinally on to the interlock strip, which causes the extension to bend the fingers open in order to engage with the body part of the base. To remove it, the procedure is reversed. (orig.) [de

  2. Biomechanical Effects of Posterior Condylar Offset and Posterior Tibial Slope on Quadriceps Force and Joint Contact Forces in Posterior-Stabilized Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Kyoung-Tak Kang

    2017-01-01

    Full Text Available This study aimed to determine the biomechanical effect of the posterior condylar offset (PCO and posterior tibial slope (PTS in posterior-stabilized (PS fixed-bearing total knee arthroplasty (TKA. We developed ±1, ±2, and ±3 mm PCO models in the posterior direction and −3°, 0°, 3°, and 6° PTS models using a previously validated FE model. The influence of changes in the PCO and PTS on the biomechanical effects under deep-knee-bend loading was investigated. The contact stress on the PE insert increased by 14% and decreased by 7% on average as the PCO increased and decreased, respectively, compared to the neutral position. In addition, the contact stress on post in PE insert increased by 18% on average as PTS increased from −3° to 6°. However, the contact stress on the patellar button decreased by 11% on average as PTS increased from −3° to 6° in all different PCO cases. The quadriceps force decreased by 14% as PTS increased from −3° to 6° in all PCO models. The same trend was found in patellar tendon force. Changes in PCO had adverse biomechanical effects whereas PTS increase had positive biomechanical effects. However, excessive PTS should be avoided to prevent knee instability and subsequent failure.

  3. Partial Cancellation

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Partial Cancellation. Full Cancellation is desirable. But complexity requirements are enormous. 4000 tones, 100 Users billions of flops !!! Main Idea: Challenge: To determine which cross-talker to cancel on what “tone” for a given victim. Constraint: Total complexity is ...

  4. Endoscopic management of posterior epistaxis.

    Science.gov (United States)

    Paul, J; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-04-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26-50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of the bleeding vessel. Of these, in four cases unsuspected diagnosis was made. Of the remaining 19, in three patients, the bleeding point could not be localized accurately and these patients were managed by anteroposterior packing. The rest of the 16 patients were managed by endoscopic cauterization. In four patients, there was recurrence of bleeding within 24 h. In one of these, cauterization controlled the bleeding while in the rest nasal packing had to be resorted to. Thus, of the 23 patients of posterior epistaxis subjected to nasal endoscopy, we could avoid nasal packing in 17 (74%). To conclude, endoscopic nasal cauterization is recommended as the first line to treatment in all cases of posterior epistaxis. This will not only prevent the uncomfortable and potentially dangerous nasal packing but also help in finding the underlying pathology.

  5. Perawatan Crossbite Posterior pada Maloklusi Angle Klas III dengan Alat Ortodontik Cekat Teknik Begg

    Directory of Open Access Journals (Sweden)

    Trio Wijayanto

    2011-12-01

    Full Text Available Latar Belakang: Crossbite posterior merupakan hubungan abnormal dari gigi-gigi posterior secara bukolingual pada rahang atas atau bawah pada saat kedua lengkung gigi berada dalam oklusi sentrik yang dapat terjadi pada satu atau kedua sisi rahang. Posterior crossbite adalah maloklusi yang paling sering muncul pada masa gigi susu dan awal gigi bercampur. Tujuan Perawatan: mengoreksi crossbite posterior dan mengembalikan fungsi pengunyahan yang baik. Kasus: Perempuan 20 tahun dengan maloklusi Angle klas III disertai crossbite posterior kanan, crowding rahang atas dan bawah. Penanganan: menggunakan alat cekat teknik Begg dengan pencabutan gigi premolar I rahang atas kiri, kedua premolar I rahang bawah, cross elastik, toe-in, dan toe out digunakan untuk koreksi crossbite. Kesimpulan: Perawatan crossbite posterior dengan teknik Begg menunjukkan hasil yang cukup memuaskan. Prognatik mandibula berkurang, crossbite terkoreksi, overjet normal, overbite normal, dan fungsi pengunyahan menjadi lebih baik.   Background: Posterior crossbite is defined as any abnormal bucal-lingual relations between posterior teeth of upper and lower jaw in centric occlusion which can occur in one side only or both. Posterior crossbite is one of the most prevalent malocclusion in primary and early mixed dentition. Purpose: to correct posterior and restore normal mastication. Case: 20 years old woman with Angle’s class II accompanied by posterior crossbite on the right side and crowding in anterior segment of upper and lower jaw. Management: using the Begg fixed appliance techniques with the extraction of upper left, and two lower first premolars. Cross elastic along with toe in and toe out on the main wire was used to correct posterior crossbite. Conclusion: Posterior crossbite treatment with Begg technique showed satisfactory results. Prognatism mandibula had reduced, regained normal overjet and overbite, and restored good mastication.

  6. Chairside fabricated fiber-reinforced composite fixed partial denture

    Directory of Open Access Journals (Sweden)

    Sufyan Garoushi

    2007-01-01

    Full Text Available The advances in the materials and techniques for adhesive dentistry have allowed the development of non-invasive or minimally invasive approaches for replacing a missing tooth in those clinical situations when conservation of adjacent teeth is needed. Good mechanical and cosmetic/aesthetic properties of fiber-reinforced composite (FRC, with good bonding properties with composite resin cement and veneering composite are needed in FRC devices. Some recent studies have shown that adhesives of composite resins and luting cements allow diffusion of the adhesives to the FRC framework of the bridges. By this so-called interdiffusion bonding is formed [1]. FRC bridges can be made in dental laboratories or chairside. This article describes a clinical case of chairside (directly made FRC Bridge, which was used according to the principles of minimal invasive approach. Treatment was performed by Professor Vallittu from the University of Turku, Finland.

  7. Esthetic Rehabilitation with a Cast Partial Denture

    Directory of Open Access Journals (Sweden)

    Suraksha Shrestha

    2017-01-01

    Full Text Available Removable partial denture is a treatment option where fixed prosthesis is not indicated. Due to its esthetic problems in the anterior region various modifications have been designed for its fabrication. This article describes an esthetic alternative using a round rest distal depression clasp for maxillary anterior teeth abutment while restoring the missing teeth with a cast partial denture.

  8. Epidural hematomas of posterior fossa

    Directory of Open Access Journals (Sweden)

    Radulović Danilo

    2004-01-01

    Full Text Available Background. Posterior fossa epidural hematomas represent 7-14% of all traumatic intracranial epidural hematomas. They are most frequently encountered posttraumatic mass lesions in the posterior fossa. The aim of this study was to identify clinical features that could lead to the early diagnosis of posterior fossa epidural hematoma. Methods. Between 1980 and 2002, 28 patients with epidural hematoma of the posterior fossa were operated on at the Institute for Neurosurgery, Belgrade. Clinical course neuroradiological investigations, and the results of surgical treatment of the patients with posterior fossa epidural hematomas were analyzed retrospectively. Results. Almost two thirds of patients were younger than 16 years of age. In 20 cases injury was caused by a fall, in 6 cases by a traffic accident, and in 2 by the assault. Clinical course was subacute or chronic in two thirds of the patients. On the admission Glasgow Coma Scale was 7 or less in 9 injured, 8-14 in 14 injured, and 15 in 5 injured patients. Linear fracture of the occipital bone was radiographically evident in 19 patients, but was intraoperatively encountered in all the patients except for a 4-year old child. In 25 patients the diagnosis was established by computer assisted tomography (CAT and in 3 by vertebral angiography. All the patients were operated on via suboccipital craniotomy. Four injured patients who were preoperatively comatose were with lethal outcome. Postoperatively, 24 patients were with sufficient neurologic recovery. Conclusion. Posterior fossa epidural hematoma should be suspected in cases of occipital injury, consciousness disturbances, and occipital bone fracture. In such cases urgent CAT-scan is recommended. Early recognition early diagnosis, and prompt treatment are crucial for good neurological recovery after surgery.

  9. MR imaging diagnosis of posterior cruciate ligament injury: importance of ancillary findings

    International Nuclear Information System (INIS)

    Hwang, Kang Ik; Lee, Jong Hwa; Kim, Young Sun; Lee, Jung Hwoi; Ki, Tae Sung; Park, Jong Oag

    1997-01-01

    To evaluate the importance of two ancillary findings of anterior tibial plateau bruise/fracture and popliteus muscle strain on MR diagnosis of posterior cruicate ligament injury. We retrospectively evaluated 48 patients with confirmed posterior cruciate ligament tear. We studied the incidence of anterior tibial plateau injury and popliteus muscle strain, and the specificity of popliteus muscle strain with or without bony injury. A complete tear of the posterior cruciate ligament was noted in 37 cases, a partial tear in 11. Anterior tibial plateau lesion was found in 21 of 48 cases (44%); This total was made up of 17/37 PCL complete tears (46%) and 4/11 partial tears (36%). The difference in the incidence of complete and partial tears is not statistically significant. Popliteus muscle injury was found in 20 of 48 cases (42%), the total consisted of 19/37 PCL complete tears (51%) and 1/11 partial tears (10%). The incidence of 42% is relatively high, approximating that of bony injury. The difference in the incidence of complete and partial tears is statistically significant (p < 0.006). Specificity for posterior cruciate ligament tear is 69%(20/29), and when concomitant with anterior tibial plateau injury is 94%(16/17). As in the case of anterior cruciate ligament injury, these documented ancillary findings of anterior tibial plateau and popliteus muscle injuries are very helpful when MR diagnosis of posterior cruciate ligament injury itself and differentiation of partial and complete rupture are doubtful

  10. Unsuccessful outcomes after posterior urethroplasty.

    Science.gov (United States)

    Engel, Oliver; Fisch, Margit

    2015-03-01

    Posterior urethroplasty is the most common strategy for the treatment of post-traumatic urethral injuries. Especially in younger patients, post-traumatic injuries are a common reason for urethral strictures caused by road traffic accidents, with pelvic fracture or direct trauma to the perineum. In many cases early endoscopic realignment is the first attempt to restore the junction between proximal and distal urethra, but in some cases primary realignment is not possible or not enough to treat the urethral injury. In these cases suprapubic cystostomy alone and delayed repair by stricture excision and posterior urethroplasty is an alternative procedure to minimise the risk of stricture recurrence.

  11. Fixed automated spray technology.

    Science.gov (United States)

    2011-04-19

    This research project evaluated the construction and performance of Boschungs Fixed Automated : Spray Technology (FAST) system. The FAST system automatically sprays de-icing material on : the bridge when icing conditions are about to occur. The FA...

  12. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  13. Posterior defects of the patella on CT arthrograms

    International Nuclear Information System (INIS)

    Lehner, K.; Reiser, M.; Hawe, W.; Smasal, V.; Technische Univ. Muenchen; Technische Univ. Muenchen

    1986-01-01

    Changes of the posterior bony and cartilaginous surfaces of the patella as seen on CT arthrograms are described in the case of bipartite patellae, fractures and ossification defects. Contrary to present opinion, cartilaginous lesions are frequently seen on CT arthrograms. This is also true for discreet and partial ossification defects which are not visible on conventional X-rays and are described here for the first time. The aetiology, morphogenesis and clinical examples are discussed. (orig.) [de

  14. Fixed mobile convergence handbook

    CERN Document Server

    Ahson, Syed A

    2010-01-01

    From basic concepts to future directions, this handbook provides technical information on all aspects of fixed-mobile convergence (FMC). The book examines such topics as integrated management architecture, business trends and strategic implications for service providers, personal area networks, mobile controlled handover methods, SIP-based session mobility, and supervisory and notification aggregator service. Case studies are used to illustrate technical and systematic implementation of unified and rationalized internet access by fixed-mobile network convergence. The text examines the technolo

  15. Partial gigantism

    Directory of Open Access Journals (Sweden)

    М.М. Karimova

    2017-05-01

    Full Text Available A girl with partial gigantism (the increased I and II fingers of the left foot is being examined. This condition is a rare and unresolved problem, as the definite reason of its development is not determined. Wait-and-see strategy is recommended, as well as correcting operations after closing of growth zones, and forming of data pool for generalization and development of schemes of drug and radial therapeutic methods.

  16. Retention of the posterior cruciate ligament versus the posterior stabilized design in total knee arthroplasty: a prospective randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    van den Akker-Scheek Inge

    2009-09-01

    Full Text Available Abstract Background Prosthetic design for the use in primary total knee arthroplasty has evolved into designs that preserve the posterior cruciate ligament (PCL and those in which the ligament is routinely sacrificed (posterior stabilized. In patients with a functional PCL the decision which design is chosen depends largely on the favour and training of the surgeon. The objective of this study is to determine whether the patient's perceived outcome and speed of recovery differs between a posterior cruciate retaining total knee arthroplasty and a posterior stabilized total knee arthroplasty. Methods/Design A randomized controlled trial will be conducted. Patients who are admitted for primary unilateral TKA due to primary osteoarthrosis are included when the following inclusion criteria are met: non-fixed fixed varus or valgus deformity less than 10 degrees, age between 55 and 85 years, body mass index less than 35 kg/m2 and ASA score (American Society of Anaesthesiologists I or II. Patients are randomized in 2 groups. Patients in the posterior cruciate retaining group will receive a prosthesis with a posterior cut-out for the posterior cruciate ligament and relatively flat topography. In patients allocated to the posterior stabilized group, in which the posterior cruciate ligament is excised, the design may substitute for this function by an intercondylar tibial prominence that articulates with the femur in flexion. Measurements will take place preoperatively and 6 weeks, 3 months, 6 months and 1 year postoperatively. At all measurement points patient's perceived outcome will be assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC. Secondary outcome measures are quality of life (SF-36 and physician reported functional status and range of motion as determined with the Knee Society Clinical Rating System (KSS. Discussion In the current practice both posterior cruciate retaining and posterior stabilized designs

  17. The appearance of a lurking ligament in Laparoscopic Sleeve Gastrectomy; Posterior Gastric Ligament

    Directory of Open Access Journals (Sweden)

    Mutlu Ünver

    2017-03-01

    Full Text Available Objective: The aim of this study was to demonstrate a lurking ligament and its various formation types and to mention the importance of this ligament in Laparoscopic sleeve gastrectomy Methods: One hundred and twelve patients had laparoscopic sleeve gastrectomy (LSG procedure in our clinic between March 2011 and September 2013. All procedures were performed with a standard operative technique. Only difference for the last 50 patients was to avoid the excessive dissection of posterior gastric wall. The existence of posterior gastric ligament was recorded and different types of posterior gastric ligament was demonstrated. Results: Posterior gastric ligament was observed in all of the cases in different formation types. Three types of ligament; complete, partial and skippy, was demonstrated. 53(47.3% of the patients had skippy, while 41 (36.6% had partial and 18 (16.1% had complete type of posterior gastric ligament. Conclusion: A ligament named as ‘posterior gastric ligament’ and its various forms were defined in the third dimensional plane of stomach. Posterior gastric ligament remains as the only structure in LSG for preventing the mobility and ability of the stomach to rotate. The excessive dissection of the posterior gastric ligament should be avoided to prevent complications such as kinking and volvulus

  18. Prevention of posterior capsular opacification

    NARCIS (Netherlands)

    Nibourg, Lisanne M; Gelens, Edith; Kuijer, Roelof; Hooymans, Johanna Mm; van Kooten, Theo G; Koopmans, Steven A

    Posterior capsular opacification (PCO) is a common complication of cataract surgery. The development of PCO is due to a combination of the processes of proliferation, migration, and transdifferentiation of residual lens epithelial cells (LECs) on the lens capsule. In the past decades, various forms

  19. The ectopic posterior pituitary gland

    African Journals Online (AJOL)

    2013-11-04

    Nov 4, 2013 ... crinology with short stature, delayed bone age and biochemical features suggestive of hypo pituitarism. Magnetic resonance imaging of the brain demonstrated a flattened anterior pituitary gland within the sella, associated with absence of the infundibular stalk and an ectopic posterior pituitary gland (Fig.

  20. One-stage posterior approaches for treatment of thoracic spinal infection: Transforaminal and costotransversectomy, compared with anterior approach with posterior instrumentation.

    Science.gov (United States)

    Kao, Fu-Cheng; Tsai, Tsung-Ting; Niu, Chi-Chien; Lai, Po-Liang; Chen, Lih-Huei; Chen, Wen-Jer

    2017-10-01

    Treating thoracic infective spondylodiscitis with anterior surgical approaches carry a relatively high risk of perioperative and postoperative complications. Posterior approaches have been reported to result in lower complication rates than anterior procedures, but more evidence is needed to demonstrate the safety and efficacy of 1-stage posterior approaches for treating infectious thoracic spondylodiscitis.Preoperative and postoperative clinical data, of 18 patients who underwent 2 types of 1-stage posterior procedures, costotransversectomy and transforaminal thoracic interbody debridement and fusion and 7 patients who underwent anterior debridement and reconstruction with posterior instrumentation, were retrospectively assessed.The clinical outcomes of patients treated with 1-stage posterior approaches were generally good, with good infection control, back pain relief, kyphotic angle correction, and either partial or solid union for fusion status. Furthermore, they achieved shorter surgical time, fewer postoperative complications, and shorter hospital stay than the patients underwent anterior debridement with posterior instrumentation.The results suggested that treating thoracic spondylodiscitis with a single-stage posterior approach might prevent postoperative complications and avoid respiratory problems associated with anterior approaches. Single-stage posterior approaches would be recommended for thoracic spine infection, especially for patients with medical comorbidities.

  1. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  2. Hematomas na fossa craniana posterior Haematomata in the posterior fossa

    Directory of Open Access Journals (Sweden)

    Mário S. Cademartori

    1969-09-01

    Full Text Available São relatados 6 casos de hematomas sub-tentorias (um de hematoma subdural crônico, quatro de hematomas intra-cerebelares, um de hematoma extra-dural. Salientando a pequena freqüência dos hematomas da fossa craniana posterior, o autor mostra a necessidade de vários exames complementares para o diagnóstico exato, indispensável para a aplicação de terapêutica cirúrgica adequada.Six cases of sub-tentorial haematomata (one chronic sub-dural, four intra-cerebellar, one extra-dural are reported. Emphasizing the relative rarity of haematomata in the posterior cranial fossa, the author claims the necessity of complementary examinations for proper diagnosis, indispensable for adequate surgical treatment.

  3. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  4. Visual attention in posterior stroke

    DEFF Research Database (Denmark)

    Fabricius, Charlotte; Petersen, Anders; Iversen, Helle K

    Objective: Impaired visual attention is common following strokes in the territory of the middle cerebral artery, particularly in the right hemisphere. However, attentional effects of more posterior lesions are less clear. The aim of this study was to characterize visual processing speed...... and apprehension span following posterior cerebral artery (PCA) stroke. We also relate these attentional parameters to visual word recognition, as previous studies have suggested that reduced visual speed and span may explain pure alexia. Methods: Nine patients with MR-verified focal lesions in the PCA......-territory (four left PCA; four right PCA; one bilateral, all >1 year post stroke) were compared to 25 controls using single case statistics. Visual attention was characterized by a whole report paradigm allowing for hemifield-specific speed and span measurements. We also characterized visual field defects...

  5. Classification of posterior vitreous detachment

    OpenAIRE

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2013-01-01

    Akihiro Kakehashi,1 Mikiko Takezawa,1 Jun Akiba21Department of Ophthalmology, Jichi Medical University, Saitama Medical Center, Saitama, 2Kanjodori Eye Clinic, Asahikawa, JapanAbstract: Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography...

  6. Traumatic posterior fossa epidural hematoma

    International Nuclear Information System (INIS)

    Ikeda, Yukio; Nakazawa, Shozo; Yamakawa, Kazuomi; Kobayashi, Shiro; Tsuji, Yukihide

    1981-01-01

    In this paper three acute cases and two subacute cases are reported. CT findings in acute cases show two different types. ''Type I'' shows crescent or lenticular high density area which is not enhanced after contrast infusion. ''Type II'' shows lenticular low density area with membranous high density region in its medial side after contrast infusion. In subacute cases plain CT scan shows lenticular iso or low density area with membranous high density region in its medial side. Forty five cases of posterior fossa epidural hematoma in the review of literature of this country are discussed. Disturbances of the consciousness are the most predominant symptoms in acute cases, while in subacute cases cerebellar signs, vomiting, headache and choked disc are noted. Angiographical examinations may not always be valuable in collecting the direct information of the existence of the epidural hematoma. Liquor cavity in the posterior fossa which is thought to serve as a buffer action of hematoma is about 20 ml, so we discuss about the volume of hematoma, especially of 20 ml, associated with clinical course and prognosis. Volume of epidural hematoma is one of the most important factors affecting clinical course and prognosis. In summary of these our experiences, we again emphasize the value of CT scan as the rapid, noninvasive, accurate radiological examination in the diagnosis of traumatic posterior fossa epidural hematoma. (author)

  7. Analysis of bone healing in flail chest injury: do we need to fix both fractures per rib?

    Science.gov (United States)

    Marasco, Silvana; Liew, Susan; Edwards, Elton; Varma, Dinesh; Summerhayes, Robyn

    2014-09-01

    Surgical rib fixation (SRF) for severe rib fracture injuries is generating increasing interest in the medical literature. It is well documented that poorly healed fractured ribs can lead to chronic pain, disability, and deformity. An unanswered question in SRF for flail chest injury is whether it is sufficient to fix one fracture per rib, on successive ribs, thus converting a flail chest injury into simple fractured ribs, or whether both ends of the floating segment of the chest wall should be fixed. This study aimed to analyze SRF in flail chest injury, assessing 3-month outcomes for nonfixed fractured rib ends in the flail segment. This is a retrospective review (2005-2013) of 60 consecutive patients who underwent SRF for flail chest injury admitted to the Alfred Hospital, Melbourne, Australia. Imaging by three-dimensional computed tomography (3D CT) of the chest at admission was compared with follow-up 3D CT at 3 months after injury. The 3-month CT scans were assessed for degree of healing and presence of residual deformity at the fracture fixation site. Follow-up CT was performed in 52 of the 60 patients. At 3 months after surgery, 86.5% of the patients had at least partial healing with good alignment and adequate fracture stabilization. Hardware failure was noted in five patients (9.6%) and occurred with the absorbable prostheses only. Six patients who had preoperative overlapping or displacement showed no improvement in deformity despite fixing the lateral fractures. Callus formation and bony bridging between adjacent ribs was often noted in the rib fractures not fixed (28 of 52 patients, 54%) This retrospective review of 3D CT chest at 3 months after rib fixation indicates that a philosophy of fixing only one fracture per rib in a flail segment does not avoid deformity and displacement, particularly in posterior rib fractures. Therapeutic study, level V; epidemiologic study, level V.

  8. Least fixed points revisited

    NARCIS (Netherlands)

    J.W. de Bakker (Jaco)

    1975-01-01

    textabstractParameter mechanisms for recursive procedures are investigated. Contrary to the view of Manna et al., it is argued that both call-by-value and call-by-name mechanisms yield the least fixed points of the functionals determined by the bodies of the procedures concerned. These functionals

  9. Characterizing fixed points

    Directory of Open Access Journals (Sweden)

    Sanjo Zlobec

    2017-04-01

    Full Text Available A set of sufficient conditions which guarantee the existence of a point x⋆ such that f(x⋆ = x⋆ is called a "fixed point theorem". Many such theorems are named after well-known mathematicians and economists. Fixed point theorems are among most useful ones in applied mathematics, especially in economics and game theory. Particularly important theorem in these areas is Kakutani's fixed point theorem which ensures existence of fixed point for point-to-set mappings, e.g., [2, 3, 4]. John Nash developed and applied Kakutani's ideas to prove the existence of (what became known as "Nash equilibrium" for finite games with mixed strategies for any number of players. This work earned him a Nobel Prize in Economics that he shared with two mathematicians. Nash's life was dramatized in the movie "Beautiful Mind" in 2001. In this paper, we approach the system f(x = x differently. Instead of studying existence of its solutions our objective is to determine conditions which are both necessary and sufficient that an arbitrary point x⋆ is a fixed point, i.e., that it satisfies f(x⋆ = x⋆. The existence of solutions for continuous function f of the single variable is easy to establish using the Intermediate Value Theorem of Calculus. However, characterizing fixed points x⋆, i.e., providing answers to the question of finding both necessary and sufficient conditions for an arbitrary given x⋆ to satisfy f(x⋆ = x⋆, is not simple even for functions of the single variable. It is possible that constructive answers do not exist. Our objective is to find them. Our work may require some less familiar tools. One of these might be the "quadratic envelope characterization of zero-derivative point" recalled in the next section. The results are taken from the author's current research project "Studying the Essence of Fixed Points". They are believed to be original. The author has received several feedbacks on the preliminary report and on parts of the project

  10. Nonsurgical treatment of an adult patient with bilateral posterior crossbite.

    Science.gov (United States)

    Liu, Renkai; Xiaoqing, Ma; Wamalwa, Peter; Zou, Shu-juan

    2011-07-01

    A woman with an Angle Class III malocclusion and bilateral posterior crossbites complaining of difficulty in chewing was treated orthodontically without surgery. The treatment comprised asymmetric extractions, a removable mandibular lingual arch constriction appliance to narrow the mandibular arch, and a standard edgewise appliance to align the teeth. Pretreatment, posttreatment, and 1-year follow-up records are shown. With this treatment strategy of constricting the mandibular arch by using a combination of removable and fixed orthodontic appliances, we achieved a good result with optimal occlusion. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  11. Fixed point theory in metric type spaces

    CERN Document Server

    Agarwal, Ravi P; O’Regan, Donal; Roldán-López-de-Hierro, Antonio Francisco

    2015-01-01

    Written by a team of leading experts in the field, this volume presents a self-contained account of the theory, techniques and results in metric type spaces (in particular in G-metric spaces); that is, the text approaches this important area of fixed point analysis beginning from the basic ideas of metric space topology. The text is structured so that it leads the reader from preliminaries and historical notes on metric spaces (in particular G-metric spaces) and on mappings, to Banach type contraction theorems in metric type spaces, fixed point theory in partially ordered G-metric spaces, fixed point theory for expansive mappings in metric type spaces, generalizations, present results and techniques in a very general abstract setting and framework. Fixed point theory is one of the major research areas in nonlinear analysis. This is partly due to the fact that in many real world problems fixed point theory is the basic mathematical tool used to establish the existence of solutions to problems which arise natur...

  12. Extremely long posterior communicating artery diagnosed by MR angiography: report of two cases.

    Science.gov (United States)

    Uchino, Akira; Suzuki, Chihiro; Tanaka, Masahiko

    2015-07-01

    We report two cases of an extremely long left posterior communicating artery (PCoA) diagnosed by magnetic resonance (MR) angiography. The PCoA arose from the normal point of the supraclinoid internal carotid artery and fused with the posterior cerebral artery (PCA) at its posterior ambient segment, forming an extremely long PCoA and extremely long precommunicating segment of the PCA. To our knowledge, this is the first report of such variation. Careful observation of MR angiographic images is important for detecting rare arterial variations. To identify these anomalous arteries on MR angiography, partial maximum-intensity-projection images are useful.

  13. СURRENT TRENDS OF THE FIXED CAPITAL CONSUMPTION

    Directory of Open Access Journals (Sweden)

    Nikolay V. Gayfulin

    2014-01-01

    Full Text Available The research article is devoted to the current trends of the fixed capital consumption, to the problems connected with the fixed capital consumption and to the innovations in the Russian economy where the increase of fixed capital consumption efficiency is of the great importance. Under the conditions of the exchange relations formation and escalating competition only those commodity producers who can make the best use of all kinds of the resources will win. The fixed capital consumption efficiency is defined as a set of a measures which is taken by the economic entities. Some of a measures are partially described in this article. Nowadays the fixed capital consumption problem is connected with the performance enhancement and optimization of the fixed assets items.

  14. Bayesian inference for partially identified models exploring the limits of limited data

    CERN Document Server

    Gustafson, Paul

    2015-01-01

    Introduction Identification What Is against Us? What Is for Us? Some Simple Examples of Partially Identified ModelsThe Road Ahead The Structure of Inference in Partially Identified Models Bayesian Inference The Structure of Posterior Distributions in PIMs Computational Strategies Strength of Bayesian Updating, Revisited Posterior MomentsCredible Intervals Evaluating the Worth of Inference Partial Identification versus Model Misspecification The Siren Call of Identification Comp

  15. Vilified and Fixed

    DEFF Research Database (Denmark)

    Jensen, Thessa; Westberg, Lysa

    , and imbalances of power between scholars and journalists on one side, and fans on the other are not rare occurrences. An analysis of a number of recent news articles, scholarly works, and websites, shows how the attempt of fixing fandom still prevails. Like Said's view on how the Orient is treated, fandom...... and tween website", 'Teen' managed to outrage fans. It took days and hundreds of comments, tweets, and mails to the publishers, before the article was taken down. Vilification in scholarly works and the media may have significantly lessened in recent years. Still, misunderstandings, applied exoticism...... is similarly exotisised, incorporated, and fixed. Scholars explain how to become better fans, attempting authority over fandom by applying rules to a culture, which already has their own. This, the notion of the 'better fan', devalues the existing discourses, rules, and traditions within fandom. The expert...

  16. Hematomas na fossa craniana posterior

    Directory of Open Access Journals (Sweden)

    Mário S. Cademartori

    1969-09-01

    Full Text Available São relatados 6 casos de hematomas sub-tentorias (um de hematoma subdural crônico, quatro de hematomas intra-cerebelares, um de hematoma extra-dural. Salientando a pequena freqüência dos hematomas da fossa craniana posterior, o autor mostra a necessidade de vários exames complementares para o diagnóstico exato, indispensável para a aplicação de terapêutica cirúrgica adequada.

  17. Traumatic Posterior Atlantoaxial Dislocation Without Associated Fracture but With Neurological Deficit

    Science.gov (United States)

    Xu, Yong; Li, Feng; Guan, Hanfeng; Xiong, Wei

    2015-01-01

    Abstract Posterior atlantoaxial dislocation without odontoid fracture is extremely rare and often results in fatal spinal cord injury. According to the reported literature, all cases presented mild or no neurologic deficit, with no definite relation to upper spinal cord injury. Little is reported about traumatic posterior atlantoaxial dislocation, with incomplete quadriplegia associated with a spinal cord injury. We present a case of posterior atlantoaxial dislocation without associated fracture, but with quadriplegia, and accompanying epidural hematoma and subarachnoid hemorrhage. The patient underwent gentle traction in the neutral position until repeated cranial computed tomography revealed no progression of the epidural hematoma. Thereafter, the atlantoaxial dislocation was reduced by using partial odontoidectomy via a video-assisted transcervical approach and maintained with posterior polyaxial screw-rod constructs and an autograft. Neurological status improved immediately after surgery, and the patient recovered completely after 1 year. Posterior fusion followed by closed reduction is the superior strategy for posterior atlantoaxial dislocation without odontoid fracture, according to literature. But for cases with severe neurological deficit, open reduction may be the safest choice to avoid the lethal complication of overdistraction of the spinal cord. Also, open reduction and posterior srew-rod fixation are safe and convenient strategies in dealing with traumatic posterior atlantoaxial dislocation patients with neurological deficit. PMID:26512572

  18. Huge interparietal posterior fontanel meningohydroencephalocele

    Directory of Open Access Journals (Sweden)

    Jorge Félix Companioni Rosildo

    2015-03-01

    Full Text Available Congenital encephalocele is a neural tube defect characterized by a sac-like protrusion of the brain, meninges, and other intracranial structures through the skull, which is caused by an embryonic development abnormality. The most common location is at the occipital bone, and its incidence varies according to different world regions. We report a case of an 1-month and 7-day-old male child with a huge interparietal-posterior fontanel meningohydroencephalocele, a rare occurrence. Physical examination and volumetric computed tomography were diagnostic. The encephalocele was surgically resected. Intradural and extradural approaches were performed; the bone defect was not primarily closed. Two days after surgery, the patient developed hydrocephaly requiring ventriculoperitoneal shunting. The surgical treatment of the meningohydroencephalocele of the interparietal-posterior fontanel may be accompanied by technical challenges and followed by complications due to the presence of large blood vessels under the overlying skin. In these cases, huge sacs herniate through large bone defects including meninges, brain, and blood vessels. The latter present communication with the superior sagittal sinus and ventricular system. A favorable surgical outcome generally follows an accurate strategy taking into account individual features of the lesion.

  19. Anatomical reconstruction of unstable trochanteric fractures through posterior approach

    Directory of Open Access Journals (Sweden)

    Partha Saha

    2015-01-01

    Full Text Available Objective Unstable intertrochanteric fractures continue to be a challenge for orthopedic surgeons due to the functional limitations it results in the postoperative period. Anatomical reconstruction of the posteromedial fragment becomes difficult through conventional lateral approach, leading to excessive fracture collapse and limping. Materials and Methods: prospective, nonrandomized study was done with 40 patients. They were operated in prone position through posterior approach. Cancellous screws or SS-wires were used to fix the greater or lesser trochanteric fragments and dynamic hip screw (DHS or dynamic condylar screw (DCS for the main two fragments. Bone grafts were used to pack cavities at the posterior trochanteric regions. Results: Fracture healing occurred earlier compared to conventional lateral approach without excessive fracture collapse in majority of cases (average time to achieve union was 13.8 weeks; range: 10–18 weeks. Good functional recovery was noted with 75% 'Good' or 'Excellent' Harris Hip Scores at 24 weeks. Conclusion: Anatomical reconstruction of unstable trochanteric fractures becomes easier through posterior approach with earlier and better functional recovery.

  20. Fixed target beams

    CERN Document Server

    Kain, V; Cettour-Cave, S; Cornelis, K; Fraser, M A; Gatignon, L; Goddard, B; Velotti, F

    2017-01-01

    The CERN SPS (Super Proton Synchrotron) serves asLHC injector and provides beam for the North Area fixedtarget experiments. At low energy, the vertical acceptancebecomes critical with high intensity large emittance fixed tar-get beams. Optimizing the vertical available aperture is a keyingredient to optimize transmission and reduce activationaround the ring. During the 2016 run a tool was developed toprovide an automated local aperture scan around the entirering.The flux of particles slow extracted with the1/3inte-ger resonance from the Super Proton Synchrotron at CERNshould ideally be constant over the length of the extractionplateau, for optimum use of the beam by the fixed target ex-periments in the North Area. The extracted intensity is con-trolled in feed-forward correction of the horizontal tune viathe main SPS quadrupoles. The Mains power supply noiseat 50 Hz and harmonics is also corrected in feed-forwardby small amplitude tune modulation at the respective fre-quencies with a dedicated additional quad...

  1. Fixed term employment

    International Nuclear Information System (INIS)

    Durant, B.W.; Schonberner, M.J.

    1999-01-01

    A series of brief notes were included with this presentation which highlighted certain aspects of contract management. Several petroleum companies have realized the benefits of taking advantage of contract personnel to control fixed G and A, manage the impacts on their organization, contain costs, to manage termination costs, and to fill gaps in lean personnel rosters. An independent contractor was described as being someone who is self employed, often with a variety of work experiences. The tax benefits and flexibility of contractor personnel were also described. Some liability aspects of hiring an independent contractor were also reviewed. The courts have developed the following 4 tests to help determine whether an individual is an employee or an independent contractor: (1) the control test, (2) the business integration test, (3) specific result test, and (4) the economic reality test

  2. Fixed Access Network Sharing

    Science.gov (United States)

    Cornaglia, Bruno; Young, Gavin; Marchetta, Antonio

    2015-12-01

    Fixed broadband network deployments are moving inexorably to the use of Next Generation Access (NGA) technologies and architectures. These NGA deployments involve building fiber infrastructure increasingly closer to the customer in order to increase the proportion of fiber on the customer's access connection (Fibre-To-The-Home/Building/Door/Cabinet… i.e. FTTx). This increases the speed of services that can be sold and will be increasingly required to meet the demands of new generations of video services as we evolve from HDTV to "Ultra-HD TV" with 4k and 8k lines of video resolution. However, building fiber access networks is a costly endeavor. It requires significant capital in order to cover any significant geographic coverage. Hence many companies are forming partnerships and joint-ventures in order to share the NGA network construction costs. One form of such a partnership involves two companies agreeing to each build to cover a certain geographic area and then "cross-selling" NGA products to each other in order to access customers within their partner's footprint (NGA coverage area). This is tantamount to a bi-lateral wholesale partnership. The concept of Fixed Access Network Sharing (FANS) is to address the possibility of sharing infrastructure with a high degree of flexibility for all network operators involved. By providing greater configuration control over the NGA network infrastructure, the service provider has a greater ability to define the network and hence to define their product capabilities at the active layer. This gives the service provider partners greater product development autonomy plus the ability to differentiate from each other at the active network layer.

  3. Nonoperative Management and Novel Imaging for Posterior Circumflex Humeral Artery Injury in Volleyball

    NARCIS (Netherlands)

    van de Pol, Daan; Planken, R. Nils; Terpstra, Aart; Pannekoek-Hekman, Marja; Kuijer, P. Paul F. M.; Maas, Mario

    2017-01-01

    We report on a 34-yr-old male elite volleyball player with symptomatic emboli in the spiking hand from a partially thrombosed aneurysm of the posterior circumflex humeral artery (PCHA) in his dominant shoulder. At initial diagnosis and follow-up, a combination of time-resolved and high-resolution

  4. Magnetic resonance imaging of hypothalamus hypophysis axis lesions; Relationship between posterior pituitary function and posterior bright spot

    Energy Technology Data Exchange (ETDEWEB)

    Shiina, Takeki; Uno, Kimiichi; Arimizu, Noboru; Yoshida, Sho (Chiba Univ. (Japan). School of Medicine); Yamada, Kenichi

    1990-04-01

    Magnetic resonance imaging (MRI) using a 0.5T superconductive machine was performed to the thirty three cases with a variety of the sellar and parasellar tumors and with dysfunction of the hypothalamus-hypophysis axis. Posterior pituitary bright spot (PBS) on T1 weighted image was evaluated with the pituitary hormonal function. These cases were 12 cases of post-treated tumors including pituitary adenoma (9 patients), suprasellar germinoma (2 patients) and craniopharyngioma (one patient), and non-tumorous conditions including 15 cases of central diabetes insipidus (DI), Syndrome of inappropriate secretion of ADH (SIADH) (one patient), Sheehan's syndrome (3 patients) and anorexia nervosa (2 patients). Pituitary bright spot was not seen in all 19 cases with overt DI. On the other hand, PBS was not seen in 9 cases without overt DI. Three cases of these 9 cases showing Sheehan's syndrome with insufficient antidiuretic hormone (ADH) secretion was considered as the state of subclinical DI. Posterior bright spot was not seen in all 13 cases of empty sella including partial empty sella. The results suggested that disappearance of PBS represents abnormality or loss of posterior pituitary function and also it was considered to be closely related to the empty sella. (author).

  5. Cisternography of the posterior fossa with metrizamide

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, N.; Saito, Y.; Miyashita, T.; Tajika, Y.

    1981-12-01

    Nine patients underwent metrizamide cisternography of the posterior fossa. Excellent opacification of the fourth ventricle resulted when the patient's head was suitably positioned and the contrast material was introduced via a C1-2 puncture. With this technique, a benign aqueductal stenosis can be readily identified and the posterior fossa and fourth ventricle can be studied easily.

  6. Selective posterior lumbosacral rhizotomy for the management ...

    African Journals Online (AJOL)

    tion in 95% of cases. The majority showed ... selective posterior rhizotomy technique whereby the cauda equina ... assessed pre- and postoperatively by means of clinical examination ... were attending cerebral palsy schools and receiving spe- cialised ... root sections on cats demonstrated clearly that posterior root section ...

  7. Evaluation of the outcomes after posterior urethroplasty.

    Science.gov (United States)

    Liberman, Daniel; Pagliara, Travis J; Pisansky, Andrew; Elliott, Sean P

    2015-03-01

    Posterior urethral injury is a clinically significant complication of pelvic fractures. The management is complicated by the associated organ injuries, distortion of the pelvic anatomy and the ensuing fibrosis that occurs with urethral injury. We report a review of the outcomes after posterior urethroplasty in the context of pelvic fracture urethral injury.

  8. Bilateral posterior crystalline lens dislocations in an otherwise healthy child

    Directory of Open Access Journals (Sweden)

    AlShehri, Omar A.

    2017-10-01

    Full Text Available Introduction: Ectopia lentis is defined as a crystalline lens displacement, either partially or completely, due to zonular abnormalities. It can be a result of trauma, hereditary ocular disease, or part of systemic diseases, like Marfan syndrome and homocystinuria.Case description: We report a case of a medically free 16-year-old girl, who was referred to our hospital complaining of poor vision and a squint in both eyes since childhood. Her history included a traffic accident when she was one-year-old. She was previously diagnosed with alternating esotropia, which was treated with glasses, alternating patching, and bilateral Botox injections. On examination, she had a visual acuity of 6/7.5 with correction in the right eye and 6/6 with correction in the left eye. She had an esotropia of 60 prism diopters, which was partially corrected to 40 prism diopters for near and distance vision. Fundus examination showed myopic changes in each eye and dislocated lenses in the posterior pole at 6 o’clock. Our case was stable, so we used conservative management with contact lenses.Conclusion: Bilateral posterior lens dislocation is very rare. A proper examination is important and early diagnosis can prevent serious complications, such as retinal detachment or pupillary block glaucoma.

  9. From Guided Surgery to Final Prosthesis with a Fully Digital Procedure: A Prospective Clinical Study on 15 Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Giorgio Andrea Dolcini

    2016-01-01

    Full Text Available Scope. To demonstrate guided implant placement and the application of fixed, implant-supported prosthetic restorations with a fully digital workflow. Methods. Over a 2-year period, all patients with partial edentulism of the posterior maxilla, in need of fixed implant-supported prostheses, were considered for inclusion in this study. The protocol required intraoral scanning and cone beam computed tomography (CBCT, the superimposition of dental-gingival information on bone anatomy, surgical planning, 3D-printed teeth-supported surgical templates, and modelling and milling of polymethylmethacrylate (PMMA temporaries for immediate loading. After 3 months, final optical impression was taken and milled zirconia frameworks and 3D-printed models were fabricated. The frameworks were veneered with ceramic and delivered to the patients. Results. Fifteen patients were selected for this study. The surgical templates were stable. Thirty implants were placed (BTK Safe®, BTK, Vicenza, Italy and immediately loaded with PMMA temporaries. After 3 months, the temporaries were replaced by the final restorations in zirconia-ceramic, fabricated with a fully digital process. At 6 months, none of the patients reported any biological or functional problems with the implant-supported prostheses. Conclusions. The present procedure for fully digital planning of implants and short-span fixed implant-supported restorations has been shown to be reliable. Further studies are needed to validate these results.

  10. Common fixed points of single-valued and multivalued maps

    Directory of Open Access Journals (Sweden)

    Yicheng Liu

    2005-01-01

    Full Text Available We define a new property which contains the property (EA for a hybrid pair of single- and multivalued maps and give some new common fixed point theorems under hybrid contractive conditions. Our results extend previous ones. As an application, we give a partial answer to the problem raised by Singh and Mishra.

  11. Impact of Partial and complete rupture of anterior cruciate ligament on medial meniscus: A cadavaric study

    Directory of Open Access Journals (Sweden)

    Wei Jiang

    2012-01-01

    Conclusions: Similar to complete rupture, partial rupture of ACL can also trigger strain concentration on medial meniscus, especially posterior horn, which may be a more critical reason for meniscus injury associated with chronic ACL deficiency.

  12. Koreksi gigitan terbalik posterior dan anterior dengan alat cekat rapid maxillary expansion dan elastik intermaksila

    Directory of Open Access Journals (Sweden)

    Retno Dewati

    2014-06-01

    Full Text Available Background: Children with anterior and posterior crossbite usually have a complaint in aesthetic and masticatory function. It could caused by bad habits and hereditary factors which made worse condition. Purpose: The purpose of this case report was to report the use of orthodontic appliance rapid maxillary expansion (RPE and intermaxillary elastic to correct posterior and anterior crossbite in teenage patient. Case: A fourteen years-old teenage female patient came to Dental Hospital Dentistry Universitas Airlangga with case of anterior posterior cross bite and unerupted permanent teeth. Case management: The case was treated using orthodontic fixed appliance rapid maxillary expansion (RPE and followed by intermaxillary elastics. The posterior cross bite treatment took 4 weeks used of orthodontic fixed appliance RPE, while, treatment of anterior cross bite which used intermaxillary elactic was done within three month to achieved normal occlusion. Conclusion: This case report showed that the orthodontic appliance rapid maxillary expansion (RPE and intermaxillary elastic could be used to correct posterior and anterior crossbite.Latar belakang: Anak dengan gigitan terbalik anterior dan posterior pada umumnya mempunyai keluhan dalam hal estetik dan fungsi pengunyahan. Kondisi gigitan terbalik biasanya disebabkan oleh adanya kebiasaan buruk dan faktor keturunan yang semakin memperparah keadaan tersebut. Tujuan: Laporan kasus ini melaporkan pemakaian alat cekat rapid maxillary expansion (RPE dan elastik intermaksila untuk mengkoreksi gigitan terbalik posterior dan anterior pada anak remaja. Kasus: Pasien remaja perempuan berusia 14 tahun datang ke Rumah Sakit Gigi dan Mulut Fakultas Kedokteran Gigi Universitas Airlangga Surabaya dengan kasus gigitan terbalik anterior posterior dan terdapat gigi permanen yang tidak tumbuh. Tatalaksana kasus: Perawatan yang dilakukan adalah koreksi gigitan terbalik dengan menggunakan alat ortodonsia cekat rapid maxillary

  13. Posterior labral injury in contact athletes.

    Science.gov (United States)

    Mair, S D; Zarzour, R H; Speer, K P

    1998-01-01

    Nine athletes (seven football offensive linemen, one defensive lineman, and one lacrosse player) were found at arthroscopy to have posterior labral detachment from the glenoid. In our series, this lesion is specific to contact athletes who engage their opponents with arms in front of the body. All patients had pain with bench pressing and while participating in their sport, diminishing their ability to play effectively. Conservative measures were ineffective in relieving their symptoms. Examination under anesthesia revealed symmetric glenohumeral translation bilaterally, without evidence of posterior instability. Treatment consisted of glenoid rim abradement and posterior labral repair with a bioabsorbable tack. All patients returned to complete at least one full season of contact sports and weightlifting without pain (minimum follow-up, > or = 2 years). Although many injuries leading to subluxation of the glenohumeral joint occur when an unanticipated force is applied, contact athletes ready their shoulder muscles in anticipation of impact with opponents. This leads to a compressive force at the glenohumeral joint. We hypothesize that, in combination with a posteriorly directed force at impact, the resultant vector is a shearing force to the posterior labrum and articular surface. Repeated exposure leads to posterior labral detachment without capsular injury. Posterior labral reattachment provides consistently good results, allowing the athlete to return to competition.

  14. Treatment implications of posterior fossa ependymoma subgroups.

    Science.gov (United States)

    Ramaswamy, Vijay; Taylor, Michael D

    2016-11-15

    Posterior fossa ependymoma comprises two distinct molecular entities, ependymoma_posterior fossa A (EPN_PFA) and ependymoma_posterior fossa B (EPN_PFB), with differentiable gene expression profiles. As yet, the response of the two entities to treatment is unclear. To determine the relationship between the two molecular subgroups of posterior fossa ependymoma and treatment, we studied a cohort of 820 patients with molecularly profiled, clinically annotated posterior fossa ependymomas. We found that the strongest predictor of poor outcome in patients with posterior fossa ependymoma across the entire age spectrum was molecular subgroup EPN_PFA, which was recently reported in the paper entitled "Therapeutic impact of cytoreductive surgery and irradiation of posterior fossa ependymoma in the molecular era: a retrospective multicohort analysis" in the Journal of Clinical Oncology. Patients with incompletely resected EPN_PFA tumors had a very poor outcome despite receiving adjuvant radiation therapy, whereas a substantial proportion of patients with EPN_PFB tumors can be cured with surgery alone.

  15. Posterior encephalopathy with vasospasm: MRI and angiography

    International Nuclear Information System (INIS)

    Weidauer, S.; Gaa, J.; Lanfermann, H.; Zanella, F.E.; Sitzer, M.; Hefner, R.

    2003-01-01

    Posterior encephalopathy is characterised by headache, impairment of consciousness, seizures and progressive visual loss. MRI shows bilateral, predominantly posterior, cortical and subcortical lesions with a distribution. Our aim was to analyse the MRI lesion pattern and angiographic findings because the pathophysiology of posterior encephalopathy is incompletely understood. We report three patients with clinical and imaging findings consistent with posterior encephalopathy who underwent serial MRI including diffusion-weighted imaging (DWI) and construction of apparent diffusion coefficient (ADC) maps, and four-vessel digital subtraction angiography (DSA). DWI revealed symmetrical subcortical and cortical parieto-occipital high signal. High and also low ADCs indicated probable vasogenic and cytotoxic oedema. On follow-up there was focal cortical laminar necrosis, while the white-matter lesions resolved almost completely, except in the arterial border zones. DSA revealed diffuse arterial narrowing, slightly more marked in the posterior circulation. These findings suggest that posterior encephalopathy may in some cases be due to diffuse, severe vasospasm affecting especially in the parieto-occipital grey matter, with its higher vulnerability to ischemia. Cerebral vasospasm due to digitoxin intoxication, resulting in posterior encephalopathy, has not yet been described previously. (orig.)

  16. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  17. Rehabilitation of Posterior Maxilla with Obturator Supported by Zygomatic Implants

    Directory of Open Access Journals (Sweden)

    Sankalp Mittal

    2018-01-01

    Full Text Available Prosthetic rehabilitation of atrophic maxilla and large maxillary defects can be done successfully by zygomatic implant-supported prosthesis. Zygomatic implants are an avant-garde to complex and invasive-free vascularised osteocutaneous flaps, distraction osteogenesis, and the solution to flap failures. A treated case of tuberculous osteomyelitis, with a class II (Aramany’s classification maxillary defect, reported to oral maxillofacial department, Government Dental College (RUHS-CODS. The defect in this group was unilateral, retaining the anterior teeth. The patient was previously rehabilitated with a removable maxillary obturator. Inadequate retention affected essential functions like speaking, mastication, swallowing, esthetics, and so on due to lack of sufficient supporting tissues. A fixed prosthetic rehabilitation of posterior maxillary defect was done with obturator supported with two single-piece zygomatic implants. At 1-year follow-up, the patient was comfortable with the prosthesis, and no further complaints were recorded.

  18. Clinical Evaluation of Small Diameter Straumann Implants in Partially Edentulous Patients: A 5-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    S. OZER

    2011-06-01

    Full Text Available Objective: The aim of the present study was to retrospectively evaluate small-diameter (3.3 mm Straumann® dental implants placed in the maxilla or the mandible over a period of 5 years in function.Materials and Methods: Twenty- eight partially edentulous patients received a total of 48 implants over a 5-year period. After the standard healing period (3 to 6 months, the implants were restored with single-tooth prostheses or fixed partial dentures. All patients were followed according to a strict maintenance program with regular recalls. The cumulative survival rates of implants were analyzed and prosthetic complications were assessed.Results: After 5 years of function, one single 10-mm-long implant in the maxillary premolar region was lost because of recurrent peri-implant infection in a female patient. Two single 10-mm-long maxillary implants placed in the posterior region were lost due to body fracture. The cumulative 5-year survival rate of the implants was 93.75 %. The most common prosthetic complication was loosening of the occlusal screw.Conclusion: Within the limited observation period and the number of patients included in this study, it may be concluded that the use of small-diameter implants appears to be predictable if clinical guidelines are followed and appropriate prosthetic restorations are provided. However, it should be noted that fatigue fracture may occur.

  19. Fixed points of quantum gravity

    OpenAIRE

    Litim, D F

    2003-01-01

    Euclidean quantum gravity is studied with renormalisation group methods. Analytical results for a non-trivial ultraviolet fixed point are found for arbitrary dimensions and gauge fixing parameter in the Einstein-Hilbert truncation. Implications for quantum gravity in four dimensions are discussed.

  20. Treatment of Spinal Tuberculosis by Debridement, Interbody Fusion and Internal Fixation via Posterior Approach Only.

    Science.gov (United States)

    Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang

    2016-02-01

    Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting

  1. Posterior alien hand syndrome: case report

    International Nuclear Information System (INIS)

    Rohde, S.; Weidauer, S.; Lanfermann, H.; Zanella, F.

    2002-01-01

    The alien hand syndrome (AHS) is involuntary uncontrolled movement of an arm with a sense of estrangement from the limb itself. AHS was initially used to describe interhemispheric disconnection phenomena in patients with lesions in the anterior corpus callosum, but it has been found in patients with posterior cerebral lesions without involvement of the corpus callosum, for example parietal infarcts or corticobasal degeneration. The posterior alien hand syndrome is less frequent and presents with nonpurposive behaviour like lifting the arm or writhing fingers. We report an 80-year-old woman with a posterior AHS of the dominant right hand. MRI showed atrophy of the pre- and postcentral gyri without involvement of the corpus callosum. We discuss the aetiology of the posterior AHS and the differences from the anterior varieties. (orig.)

  2. Posterior reversible encephalopathy syndrome: Some novel ...

    African Journals Online (AJOL)

    The third, a thalassaemic child receiving regular blood transfusions, had PRES ... anterior brain instead of the classically described posterior parts of .... 7 months. 3 years. 5 years. 4 years. Gender. Female. Male. Female. Female ... Developed.

  3. Congenital abnormalities of the posterior fossa.

    Science.gov (United States)

    Bosemani, Thangamadhan; Orman, Gunes; Boltshauser, Eugen; Tekes, Aylin; Huisman, Thierry A G M; Poretti, Andrea

    2015-01-01

    The frequency and importance of the evaluation of the posterior fossa have increased significantly over the past 20 years owing to advances in neuroimaging. Nowadays, conventional and advanced neuroimaging techniques allow detailed evaluation of the complex anatomic structures within the posterior fossa. A wide spectrum of congenital abnormalities has been demonstrated, including malformations (anomalies due to an alteration of the primary developmental program caused by a genetic defect) and disruptions (anomalies due to the breakdown of a structure that had a normal developmental potential). Familiarity with the spectrum of congenital posterior fossa anomalies and their well-defined diagnostic criteria is crucial for optimal therapy, an accurate prognosis, and correct genetic counseling. The authors discuss the spectrum of posterior fossa malformations and disruptions, with emphasis on neuroimaging findings (including diagnostic criteria), neurologic presentation, systemic involvement, prognosis, and risk of recurrence. RSNA, 2015

  4. POSTERIOR APPROACH FOR HIP ARTHROPLASTY: A SINGLE ...

    African Journals Online (AJOL)

    postulated advantages and disadvantages. Objective: Presentation of a case series of primary and revision arthroplasty utilizing the posterior approach. ... Centre over a period of one year were queried and data extracted and recorded.

  5. Posterior Fossa Tumors and Intellectual Impairment

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2005-01-01

    Full Text Available The effect of cerebellar damage on intellectual function in 76 children treated surgically for malignant posterior fossa tumor was investigated at the Gustave Roussy Institute, Villejuif, and the Department of Pediatric Neurosurgery, Necker Hospital, Paris, France.

  6. Treatment planning: implant-supported partial overdentures.

    Science.gov (United States)

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the

  7. CT and angiographic appearances of hepatocellular carcinoma partially fed by right inferior phrenic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu [Tokyo Univ. (Japan). Faculty of Medicine

    1983-04-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially fed by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery.

  8. CT and angiographic appearances of hepatocellular carcinoma partially feeded by right inferior phrenic artery

    International Nuclear Information System (INIS)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu

    1983-01-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially feeded by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery. (author)

  9. CERN: Fixed target targets

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1993-03-15

    Full text: While the immediate priority of CERN's research programme is to exploit to the full the world's largest accelerator, the LEP electron-positron collider and its concomitant LEP200 energy upgrade (January, page 1), CERN is also mindful of its long tradition of diversified research. Away from LEP and preparations for the LHC proton-proton collider to be built above LEP in the same 27-kilometre tunnel, CERN is also preparing for a new generation of heavy ion experiments using a new source, providing heavier ions (April 1992, page 8), with first physics expected next year. CERN's smallest accelerator, the LEAR Low Energy Antiproton Ring continues to cover a wide range of research topics, and saw a record number of hours of operation in 1992. The new ISOLDE on-line isotope separator was inaugurated last year (July, page 5) and physics is already underway. The remaining effort concentrates around fixed target experiments at the SPS synchrotron, which formed the main thrust of CERN's research during the late 1970s. With the SPS and LEAR now approaching middle age, their research future was extensively studied last year. Broadly, a vigorous SPS programme looks assured until at least the end of 1995. Decisions for the longer term future of the West Experimental Area of the SPS will have to take into account the heavy demand for test beams from work towards experiments at big colliders, both at CERN and elsewhere. The North Experimental Area is the scene of larger experiments with longer lead times. Several more years of LEAR exploitation are already in the pipeline, but for the longer term, the ambitious Superlear project for a superconducting ring (January 1992, page 7) did not catch on. Neutrino physics has a long tradition at CERN, and this continues with the preparations for two major projects, the Chorus and Nomad experiments (November 1991, page 7), to start next year in the West Area. Delicate neutrino oscillation effects could become visible for the first

  10. Posterior atlantoaxial dislocation without odontoid fracture

    International Nuclear Information System (INIS)

    Chaudhary, Reema; Raut, Abhijit; Chaudhary, Kshitij; Metkar, Umesh; Rathod, Ashok; Sanghvi, Darshana

    2008-01-01

    We report a case of posterior atlantoaxial dislocation without a fracture of the odontoid in a 35-year-old woman. There have been nine reported cases of similar injury in the English literature. The integrity of the transverse ligament following posterior atlantoaxial dislocations has not been well documented in these reports. In the present case, MRI revealed an intact transverse ligament, which probably contributed to the stability of the C1-C2 complex following closed reduction. (orig.)

  11. Posterior amorphous corneal dystrophy: case report

    OpenAIRE

    Oliveira, Lauro Augusto de [UNIFESP; Vieira, Luiz Antônio [UNIFESP; Freitas, Denise de [UNIFESP; Sousa, Luciene Barbosa de [UNIFESP

    2006-01-01

    O objetivo deste trabalho é alertar o oftalmologista da possibilidade de se deparar com casos raros de distrofias corneanas. Neste caso correlacionamos os achados clínicos da distrofia amorfa posterior com refração, topografia e biomicroscopia ultra-sônica.The purpose of this paper is to warn the ophthalmologist about the possibility of facing rare cases of corneal dystrophies. Clinical findings of a case of posterior amorphous dystrophy were correlated with refraction, topography, and ultras...

  12. Mature teratoma of the posterior mediastinum

    Energy Technology Data Exchange (ETDEWEB)

    Kurosaki, Y.; Tanaka, Y.O.; Itai, Y. [Department of Radiology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki-ken 305 (Japan)

    1998-02-01

    The vast majority of germ cell tumors in the thorax arise at or near the thymus. We report a case of a 41-year-old man with mature teratoma of the posterior mediastinum. He was asymptomatic and was incidentally found to have a posterior mediastinal mass. Computed tomography was helpful in suggesting a diagnosis of mature teratoma by demonstrating the presence of fat and calcification. The differential diagnosis included neurogenic tumors, liposarcoma, and extramedullary hematopoiesis. (orig.) With 2 figs., 18 refs.

  13. Mature teratoma of the posterior mediastinum

    International Nuclear Information System (INIS)

    Kurosaki, Y.; Tanaka, Y.O.; Itai, Y.

    1998-01-01

    The vast majority of germ cell tumors in the thorax arise at or near the thymus. We report a case of a 41-year-old man with mature teratoma of the posterior mediastinum. He was asymptomatic and was incidentally found to have a posterior mediastinal mass. Computed tomography was helpful in suggesting a diagnosis of mature teratoma by demonstrating the presence of fat and calcification. The differential diagnosis included neurogenic tumors, liposarcoma, and extramedullary hematopoiesis. (orig.)

  14. An unusual cause of posterior mediastinal cyst

    Directory of Open Access Journals (Sweden)

    Sahajal Dhooria

    2015-01-01

    Full Text Available Cystic lesions of the mediastinum may be congenital or acquired. The differential diagnosis depends on their location in the mediastinum. Cysts in the posterior mediastinum are generally developmental cysts and are neurogenic or of foregut origin. We report the case of a 14-year-old boy, who presented with dry cough and progressively increasing breathlessness, and was found to have a cystic lesion in the posterior mediastinum. Fine needle aspiration from the cyst helped make a diagnosis of tuberculosis.

  15. Analytic posteriors for Pearson's correlation coefficient.

    Science.gov (United States)

    Ly, Alexander; Marsman, Maarten; Wagenmakers, Eric-Jan

    2018-02-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open-source software package JASP.

  16. Analytic posteriors for Pearson's correlation coefficient

    OpenAIRE

    Ly, A.; Marsman, M.; Wagenmakers, E.-J.

    2018-01-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open‐source software package JASP.

  17. Post-partum posterior reversible encephalopathy syndrome

    OpenAIRE

    B. V. Triveni; Salman Mohammed Sheikh; Deepak Shedde

    2014-01-01

    Posterior Reversible Encephalopathy Syndrome (PRES) is a clinicopathological syndrome associated with various clinical conditions presenting with headache, encephalopathy, seizure and cortical visual disturbances. Radiological findings in PRES are thought to be due to vasogenic edema predominantly in posterior cerebral hemispheres and are reversible with appropriate management. We present a case of post partum PRES,A 29 year old primigravida of 33 weeks 3 days period of gestation who prese...

  18. Delayed Single Stage Perineal Posterior Urethroplasty

    International Nuclear Information System (INIS)

    Ali, S.; Shahnawaz; Shahzad, I.; Baloch, M. U.

    2015-01-01

    Objective: To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Study Design: Descriptive case series. Place and Duration of Study: Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Methodology: Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Results: Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patients age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3 percentage) experienced recurrent stricture during first 10 months. Five (16.6 percentage) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6 percentage) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3 percentage with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Conclusion: Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures. (author)

  19. Delayed Single Stage Perineal Posterior Urethroplasty.

    Science.gov (United States)

    Ali, Shahzad; Shahnawaz; Shahzad, Iqbal; Baloch, Muhammad Umar

    2015-06-01

    To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Descriptive case series. Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patient's age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3%) experienced recurrent stricture during first 10 months. Five (16.6%) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6%) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3% with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures.

  20. Early endoscopic realignment in posterior urethral injuries.

    Science.gov (United States)

    Shrestha, B; Baidya, J L

    2013-01-01

    Posterior urethral injury requires meticulous tertiary care and optimum expertise to manage successfully. The aim of our study is to describe our experiences with pelvic injuries involving posterior urethra and their outcome after early endoscopic realignment. A prospective study was carried out in 20 patients with complete posterior urethral rupture, from November 2007 till October 2010. They presented with blunt traumatic pelvic fracture and underwent primary realignment of posterior urethra in our institute. The definitive diagnosis of urethral rupture was made after retrograde urethrography and antegrade urethrography where applicable. The initial management was suprapubic catheter insertion after primary trauma management in casualty. After a week of conservative management with intravenous antibiotics and pain management, patients were subjected to the endoscopic realignment. The follow up period was at least six months. The results were analyzed with SPSS software. After endoscopic realignment, all patients were advised CISC for the initial 3 months. All patients voided well after three months of CISC. However, 12 patients were lost to follow up by the end of 6 postoperative months. Out of eight remaining patients, two had features of restricture and were managed with DVU followed by CISC again. One patient with restricture had some degree of erectile dysfunction who improved significantly after phospodiesterase inhibitors. None of the patients had features of incontinence. Early endoscopic realignment of posterior urethra is a minimally invasive modality in the management of complete posterior urethral injury with low rates of incontinence and impotency.

  1. Traumatic lesions of the posterior urethra.

    Science.gov (United States)

    Velarde-Ramos, L; Gómez-Illanes, R; Campos-Juanatey, F; Portillo-Martín, J A

    2016-11-01

    The posterior urethral lesions are associated with pelvis fractures in 5-10% of cases. The posterior urethra is attached to the pelvis bone by puboprostatic ligaments and the perineal membrane, which explains why disruption of the pelvic ring can injure the urethra at this level. To identify suspected cases of posterior urethral trauma and to perform the diagnosis and its immediate or deferred management. Search in PubMed of articles related to traumatic posterior urethral lesions, written in English or Spanish. We reviewed the relevant publications including literature reviews and chapters from books related to the topic. With patients with pelvis fractures, we must always rule out posterior urethral lesions. The diagnostic examination of choice is retrograde urethrography, which, along with the severity of the condition, will determine the management in the acute phase and whether the treatment will be performed immediately or deferred. Early diagnosis and proper acute management decrease the associated complications, such as strictures, urinary incontinence and erectile dysfunction. Despite the classical association between posterior urethral lesions and pelvic fractures, the management of those lesions (whether immediate or deferred) remains controversial. Thanks to the growing interest in urethral disease, there are an increasing number of studies that help us achieve better management of these lesions. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Removable partial denture on osseointegrated implants and natural teeth.

    Science.gov (United States)

    Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng

    2007-01-01

    Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.

  3. Echocardiographic Wall Motion Abnormality in Posterior Myocardial Infarction: The Diagnostic Value of Posterior Leads

    Directory of Open Access Journals (Sweden)

    A Darehzereshki

    2008-06-01

    Full Text Available Background: For the purpose of ascertaining myocardial infarction (MI and ischemia, the sensitivity of the initial 12-lead ECG is inadequate. It is risky to diagnose posterior MI using only precordial reciprocal changes, since the other leads may be more optimally positioned for the identification of electrocardiographic changes. In this study, we evaluated the relationship between electrocardiography changes and wall motion abnormalities in patients with posterior MI for earlier and better diagnosis of posterior MI.Methods: In this prospective cross-sectional study, we enrolled patients with posterior MI who had come to the Emergency Department of Shariati Hospital with their first episode of chest pain. A 12-lead surface electrocardiogram using posterior leads (V7-V9 was performed for all participants. Patients with ST elevation >0.05 mV or pathologic Q wave in the posterior leads, as well as those with specific changes indicating posterior MI in V1-V2, were evaluated by echocardiography in terms of wall motion abnormalities. All data were analyzed using SPSS and p<0.05 were considered statistically significant.Results: Of a total 79 patients enrolled, 48 (60.8% were men, and the mean age was 57.35±8.22 years. Smoking (54.4% and diabetes (48% were the most prevalent risk factors. In the echocardiographic evaluation, all patients had wall motion abnormalities in the left ventricle and 19 patients (24.1% had wall motion abnormalities in the right ventricle. The most frequent segment with motion abnormality among the all patients was the mid-posterior. The posterior leads showed better positive predictive value than the anterior leads for posterior wall motion abnormality.Conclusion: Electrocardiography of the posterior leads in patients with acute chest pain can help in earlier diagnosis and in time treatment of posterior MI.

  4. CERN: Fixed target targets

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Full text: While the immediate priority of CERN's research programme is to exploit to the full the world's largest accelerator, the LEP electron-positron collider and its concomitant LEP200 energy upgrade (January, page 1), CERN is also mindful of its long tradition of diversified research. Away from LEP and preparations for the LHC proton-proton collider to be built above LEP in the same 27-kilometre tunnel, CERN is also preparing for a new generation of heavy ion experiments using a new source, providing heavier ions (April 1992, page 8), with first physics expected next year. CERN's smallest accelerator, the LEAR Low Energy Antiproton Ring continues to cover a wide range of research topics, and saw a record number of hours of operation in 1992. The new ISOLDE on-line isotope separator was inaugurated last year (July, page 5) and physics is already underway. The remaining effort concentrates around fixed target experiments at the SPS synchrotron, which formed the main thrust of CERN's research during the late 1970s. With the SPS and LEAR now approaching middle age, their research future was extensively studied last year. Broadly, a vigorous SPS programme looks assured until at least the end of 1995. Decisions for the longer term future of the West Experimental Area of the SPS will have to take into account the heavy demand for test beams from work towards experiments at big colliders, both at CERN and elsewhere. The North Experimental Area is the scene of larger experiments with longer lead times. Several more years of LEAR exploitation are already in the pipeline, but for the longer term, the ambitious Superlear project for a superconducting ring (January 1992, page 7) did not catch on. Neutrino physics has a long tradition at CERN, and this continues with the preparations for two major projects, the Chorus and Nomad experiments (November 1991, page 7), to start next year in the West Area. Delicate neutrino oscillation effects could become

  5. Magnetic resonance imaging of the posterior cruciate ligament in flexion.

    Science.gov (United States)

    Craddock, William; Smithers, Troy; Harris, Craig; du Moulin, William; Molnar, Robert

    2018-06-01

    Posterior cruciate ligament (PCL) injuries of the knee are common and sometimes difficult to diagnose. Magnetic resonance imaging (MRI), performed using standard orthogonal plane views, is the investigation of choice. It can be particularly difficult to differentiate acute partial and complete tears and identify elongation of chronic healed tears. The aim of the paper is to describe a new method of positioning the patient with the knee flexed at 90°, allowing the PCL to be visualised in a position of greatest length and tension which may assist in differentiating and identifying these injuries. Four symptomatic patients with suspected PCL injuries, two acute and two chronic, were MRI scanned using a routine protocol with the knee in extension before performing oblique sagittal fast spin-echo (FSE) proton-density (PD) sequences with the knee positioned in 90° of flexion. The appearance of the PCLs were then qualitatively assessed. MRI scanning with the knee in flexion identified more extensive PCL injury than standard imaging. In the two patients with acute injuries, partial tears on the standard orthogonal plane views were found to be complete ruptures. In the two patients with chronic injuries, elongation of the PCL not identifiable on the standard orthogonal plane views was apparent. MRI scanning of the PCL with the knee flexed at 90° may help in differentiating partial and complete ruptures of the PCL and identifying elongation of the PCL in chronic injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Flexible thermoplastic denture base materials for aesthetical removable partial denture framework.

    Science.gov (United States)

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-10-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated, but location of clasps may affect aesthetics. So, when patient is concerned about aesthetics, flexible partial dentures which is aesthetically superior to flipper and cast partial dentures, may be considered. But for the success of flexible removable partial denture, proper diagnosis, treatment planning and insertion technique of this prosthesis is very important, which have been thoroughly described in this article.

  7. National Radiological Fixed Lab Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Radiological Fixed Laboratory Data Asset includes data produced in support of various clients such as other EPA offices, EPA Regional programs, DOE,...

  8. Can mushrooms fix atmospheric nitrogen?

    Indian Academy of Sciences (India)

    Unknown

    Introduction. Rhizobium is a genus of symbiotic N2-fixing soil bacteria that induce ... To produce biofilm cultures, a 2 × 2 cm yeast manitol agar. (YMA) slab was .... determination of antibiotic susceptibilities of bacterial biofilms;. J. Clin. Microbiol.

  9. Elevated Fixed Platform Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Elevated Fixed Platform (EFP) is a helicopter recovery test facility located at Lakehurst, NJ. It consists of a 60 by 85 foot steel and concrete deck built atop...

  10. Partial tooth gear bearings

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2010-01-01

    A partial gear bearing including an upper half, comprising peak partial teeth, and a lower, or bottom, half, comprising valley partial teeth. The upper half also has an integrated roller section between each of the peak partial teeth with a radius equal to the gear pitch radius of the radially outwardly extending peak partial teeth. Conversely, the lower half has an integrated roller section between each of the valley half teeth with a radius also equal to the gear pitch radius of the peak partial teeth. The valley partial teeth extend radially inwardly from its roller section. The peak and valley partial teeth are exactly out of phase with each other, as are the roller sections of the upper and lower halves. Essentially, the end roller bearing of the typical gear bearing has been integrated into the normal gear tooth pattern.

  11. Application of ultrasound in the diagnosis of posterior vitreous detachment

    Directory of Open Access Journals (Sweden)

    Hui-Wei Wang

    2013-12-01

    Full Text Available AIM: To investigate the utility of ultrasound in the diagnosis of posterior vitreous detachment(PVD. METHODS: From September 2011 to September 2012, 506 eyes of 305 cases(male 191, female 114of PVD patients in our hospital were checked and analyzed with ultrasound.RESULTS: Totally, 179 eyes were diagnosed as partial PVD, the proportion was 35.4%. And 327 eyes were diagnosed as complete PVD, the proportion was 64.6%. Among the 61 eyes(12.1%with a small amount of hemorrhage of vitreous humor,retinal breaks of 26 eyes(5.1%were founded. Given the photocoagulation nicely heal to the breaks and then recovered. CONCLUSION:Ultrasonography can accurately diagnose PVD. It has non-invasive,convenience, and other characteristics, and it is worthy of clinical popularization.

  12. Essays on partial retirement

    NARCIS (Netherlands)

    Kantarci, T.

    2012-01-01

    The five essays in this dissertation address a range of topics in the micro-economic literature on partial retirement. The focus is on the labor market behavior of older age groups. The essays examine the economic and non-economic determinants of partial retirement behavior, the effect of partial

  13. Management of posterior urethral disruption injuries.

    Science.gov (United States)

    Myers, Jeremy B; McAninch, Jack W

    2009-03-01

    Posterior urethral disruption is a traumatic injury to the male urethra, which most often results from pelvic fracture. After trauma, the distraction defect between the two ends of the urethra often scars and becomes fibrotic, blocking the urethra and bladder emptying. Increasing evidence suggests that many posterior urethral disruptions occur at the junction between the membranous urethra and the bulbar urethra, which is distal to the rhabdosphincter. In the acute setting, when a posterior urethral disruption is suspected, retrograde urethrography should be performed. Posterior urethral disruptions can be managed acutely by realignment of the urethra over a urethral catheter or by placement of a suprapubic catheter for bladder drainage only. Once fibrosis has stabilized, the patient can undergo posterior urethroplasty. In most cases, this procedure can be performed via a perineal approach in a single-stage surgery. The results of this single-stage perineal urethroplasty are excellent, and a patent urethra can be re-established in the majority of men who undergo surgery.

  14. Removable partial dentures: use of rapid prototyping.

    Science.gov (United States)

    Lima, Julia Magalhaes Costa; Anami, Lilian Costa; Araujo, Rodrigo Maximo; Pavanelli, Carlos A

    2014-10-01

    The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures. © 2014 by the American College of Prosthodontists.

  15. Anterior versus posterior, and rim-rent rotator cuff tears: prevalence and MR sensitivity

    International Nuclear Information System (INIS)

    Tuite, M.J.; Turnbull, J.R.; Orwin, J.F.

    1998-01-01

    Purpose. To determine the relative distribution of the locations of rotator cuff tears, and the sensitivity of anterior versus posterior tears on MR images. Patients and methods. We identified 110 consecutive patients who had a shoulder MR and either a partial-thickness or a small full-thickness rotator cuff tear diagnosed at arthroscopy. MR sensitivity and patient age were compared between patients with tears in the anterior and posterior halves of the cuff. In addition, in patients with partial tears less than 2 cm in diameter, an age comparison between those with tears in the critical zone and those with articular surface tears adjacent to the bony insertion (rim-rent tear) was performed. Results. The tear was centered in the anterior half of the rotator cuff in 79% of the patients younger than 36 years old, and in 89% of the patients 36 years old and over. The average age of the patients with tears in the anterior half (44 years) was not significantly different from the average age of those with posterior tears (40 years). The sensitivity of MR for anterior tears was 0.69, and for posterior tears it was 0.56. Five of the nine rim-rent tears (0.56) were interpreted correctly on the original MR report; two of the other tears were misinterpreted as intratendinous fluid but were diagnosable in retrospect. Conclusion. Even in patients less than 36 years old, most partial and small full-thickness rotator cuff tears are centered in the anterior half of the supraspinatus. Although our figure for MR sensitivity for these tears is lower than in recent articles, we found no significant difference between the sensitivity of MR for diagnosing posterior tears versus tears in the anterior half of the supraspinatus tendon. Rim-rent tears can be mistaken for intratendinous signal, and should be carefully looked for in younger patients with shoulder pain. (orig.)

  16. Late presentation of posterior urethral valves.

    Science.gov (United States)

    Jalbani, Imran Khan; Biyabani, Syed Raziuddin

    2014-05-01

    Presence of posterior urethral valves (PUV) is the most common cause of urinary tract obstruction in the male neonate. Late presentation occurs in 10% of cases. We present a case of PUVs in an adult male who presented with history of obstructive lower urinary tract symptoms and hematuria. On evaluation, he was found to have raised serum creatinine level. A voiding cystourethrogram (VCUG) could not be completely performed because of narrowing in the posterior urethra. A rigid urethrocystoscopy was performed at which he was found to have type-I posterior urethral valve which were fulgurated. A repeat uroflowmetry revealed maximum flow rate of 12 ml/second. This case highlights that PUVs is not solely a disease of infancy but may also present late. VCUG is the radiological investigation of choice but the diagnosis may be missed. A urethrocystoscopy is advised if there is a high index of suspicion.

  17. The bihemispheric posterior inferior cerebellar artery

    International Nuclear Information System (INIS)

    Cullen, Sean P.; Ozanne, Augustin; Alvarez, Hortensia; Lasjaunias, Pierre

    2005-01-01

    Rarely, a solitary posterior inferior cerebellar artery (PICA) will supply both cerebellar hemispheres. We report four cases of this variant. We present a retrospective review of clinical information and imaging of patients undergoing angiography at our institution to identify patients with a bihemispheric PICA. There were four patients: three males and one female. One patient presented with a ruptured arteriovenous malformation, and one with a ruptured aneurysm. Two patients had normal angiograms. The bihemispheric PICA was an incidental finding in all cases. The bihemispheric vessel arose from the dominant left vertebral artery, and the contralateral posterior inferior cerebellar artery was absent or hypoplastic. In all cases, contralateral cerebellar supply arose from a continuation of the ipsilateral PICA distal to the choroidal point and which crossed the midline dorsal to the vermis. We conclude that the PICA may supply both cerebellar hemispheres. This rare anatomic variant should be considered when evaluating patients with posterior fossa neurovascular disease. (orig.)

  18. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  19. Malignant ectomesenchymoma of the posterior mediastinum

    International Nuclear Information System (INIS)

    Khan, M. H.; Iqbal, R.; Hafeez-UR-Rehman; Yaqub, N.; Anwar-ul-Haq

    2001-01-01

    The surgical management of a four years old female child, presented at the Islamic International Medical Complex (IIMC), Islamabad, with three months history of recurrent chest infections and failure to thrive, is discussed. Posterior mediastinal tumor was diagnosed radiologically. Tumor had flimsy attachments with pericardium and thoracic aorta but was densely adherent with lower lobe of left lung. The tumor was completely removed along with a segment of lung. The postoperative recovery was uneventful. The diagnosis of malignant ectomesenchymoma was made on histopathology. The patients is well in follow-up. This is the first reported case of malignant ectomesenchymoma arising within posterior mediastinum. (author)

  20. Transverse posterior element fractures associated with torsion

    International Nuclear Information System (INIS)

    Abel, M.S.

    1989-01-01

    Six examples of a previously undescribed class of transverse vertebral element fractures are presented. These fractures differ from Chance and Smith fractures and their variants in the following respects: (1) the etiology is torsion and not flexion; (2) there is neither distraction of posterior ring fragments nor posterior ligament tears; (3) in contrast to Chance and Smith fractures, extension of the fracture into the vertebral body is absent or minimal; (4) the transverse process of the lumbar vertebra is avulsed at its base with a vertical fracture, not split horizontally. These fractures occur in cervical, lumbar, and sacral vertebrae in normal or compromised areas of the spine. (orig.)

  1. Posterior leukoencephalopathy syndrome in poststretococcal acute glomerulonephritis

    International Nuclear Information System (INIS)

    Bazzino Borzone, F.; Pandolfo Arias, M.; Protasio Palomino, L.; Pujadas Ferrer, M.; Cerisola Cardozo, A.; Gonzalez, G.; Caggiani Malzone, M.; Rubio Santoro, I.

    2005-01-01

    Reversible posterior leukoencephalopathy (LEPR) is a clinical entity that affects radiation usually the white matter of the cerebral hemispheres. It is frequently associated with acute arterial hypertension and immunosuppressive therapy, among other causes. The clinical presentation is varied, with headache, nausea, vomiting, impaired consciousness and abnormal behavior, seizures and visual disturbances, symptoms that often regress. Computed tomography (CT) and magnetic resonance imaging (MRI) images show white matter edema predominantly in posterior regions of the brain. We present a 10 year old boy with leprosy in the course of a nephrotic syndrome secondary to acute diffuse glomerunefritis (GNDA) poststreptococcal. (author) [es

  2. Neurenteric cyst of the posterior mediastinum

    International Nuclear Information System (INIS)

    Setty, H.A.N.; Hegde, K.K.S.; Narvekar, V.N.

    2005-01-01

    We report a case of a large posterior mediastinal neurenteric cyst in a neonate demonstrated by chest radiographs, barium swallow examination, ultrasonography and CT of the thorax. All the investigations revealed a large posterior mediastinal cystic mass with vertebral anomalies in the form of scoliosis and hemivertebra. The cyst was completely excised by a right posterolateral thoracotomy and biopsy showed the features of a neurenteric cyst. The rarity of the lesion prompted us to report this case Copyright (2005) Blackwell Publishing Asia Pty Ltd

  3. The effect of implant-supported removable partial dentures on oral health quality of life.

    Science.gov (United States)

    Gates, W Day; Cooper, Lyndon F; Sanders, Anne E; Reside, Glenn J; De Kok, Ingeborg J

    2014-02-01

    Removable partial dentures (RPDs) represent standard treatment for partial edentulism despite major shortcomings. To alleviate these shortcomings, endosseous implants provide support and stability as well as contribute to maintenance of alveolar bone. This prospective, within subject, time series study evaluated patient-based outcomes of RPDs compared to implant-supported removable partial dentures (ISRPDs). The study hypothesis was that the ISRPD would substantially improve oral health quality of life for patients. Seventeen patients requesting new mandibular Kennedy I or II RPDs received one 6-mm dental implant in one or both of the posterior edentulous areas. After healing, conventional RPDs were fabricated and delivered. Twelve weeks later, second-stage surgery was performed, and ball abutments with Clix attachments were inserted, thereby converting the prostheses to ISRPDs. Oral health quality of life was evaluated using the 49-item Oral Health Impact Profile (OHIP-49) questionnaire. The OHIP-49 was administered prior to treatment (baseline), at 6 and 12 weeks following RPD delivery and at 6 and 12 weeks following ISRPD conversion. Radiographic evaluation was performed at 6 and 12 weeks following ISRPD conversion. In statistical analysis, a fixed-slope random intercept variance components model took account of the multiple observations per person over time. In 17 subjects, 29 of 30 implants survived. The failed implant was replaced without complications. Abutment complications were limited to one abutment loosening and one attachment replacement. Minor prosthodontic complications were recorded. The OHIP-49 score reduced by 11.8 points, on average, at 12 weeks following ISRPD conversion (P = 0.011). Patients reported improved oral health following conversion to an ISRPD from RPD. The ISRPD involving short implants is one treatment option that should be considered when treatment planning Kennedy Class I and II patients. © 2012 John Wiley & Sons A/S.

  4. Posterior defects of the patella on CT arthrograms. Demonstration and differential diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, K.; Reiser, M.; Hawe, W.; Smasal, V.

    1986-01-01

    Changes of the posterior bony and cartilaginous surfaces of the patella as seen on CT arthrograms are described in the case of bipartite patellae, fractures and ossification defects. Contrary to present opinion, cartilaginous lesions are frequently seen on CT arthrograms. This is also true for discreet and partial ossification defects which are not visible on conventional X-rays and are described here for the first time. The aetiology, morphogenesis and clinical examples are discussed.

  5. The effects of superimposed tilt and lower body negative pressure on anterior and posterior cerebral circulations

    OpenAIRE

    Tymko, Michael M.; Rickards, Caroline A.; Skow, Rachel J.; Ingram?Cotton, Nathan C.; Howatt, Michael K.; Day, Trevor A.

    2016-01-01

    Abstract Steady?state tilt has no effect on cerebrovascular reactivity to increases in the partial pressure of end?tidal carbon dioxide (PETCO 2). However, the anterior and posterior cerebral circulations may respond differently to a variety of stimuli that alter central blood volume, including lower body negative pressure (LBNP). Little is known about the superimposed effects of head?up tilt (HUT; decreased central blood volume and intracranial pressure) and head?down tilt (HDT; increased ce...

  6. [Finite element analysis of stress changes of posterior spinal pedicle screw infixation].

    Science.gov (United States)

    Yan, Jia-Zhi; Wu, Zhi-Hong; Xu, Ri-Xin; Wang, Xue-Song; Xing, Ze-Jun; Zhao, Yu; Zhang, Jian-Guo; Shen, Jian-Xiong; Wang, Yi-Peng; Qiu, Gui-Xing

    2009-01-06

    To evaluate the mechanical response of L3-L4 segment after posterior interfixation with a transpedicle screw system. Spiral CT machine was used to conduct continuous parallel scan on the L3-L4 section of a 40-year-old healthy male Chinese. The image data thus obtained were introduced into MIMICS software to reconstruct the 2-D data into volume data and obtain 3-D models of every element.. Pro/3-D model construction software system was used to simulate the 3-D entity of L3-L4 fixed by screw robs through spinal pedicle via posterior approach that was introduced into the finite element software ABAQUS to construct a 3-D finite element model. The stress changes on the vertebrae and screw under the axial pressure of 0.5 mPa was analyzed. Under the evenly distributed pressure the displacement of the L4 model was 0.00125815 mm, with an error of only 0.8167% from the datum displacement. The convergence of the model was good. The stress of the fixed vertebral body, intervertebral disc, and internal fixators changed significantly. The stress concentration zone of the intervertebral disc turned from the posterolateral side to anterolateral side. The stress produced by the fixed vertebral bodies decreased significantly. Obvious stress concentration existed in the upper and lower sides of the base of screw and the fixed screw at the upper vertebral body bore greater stress than the lower vertebral body. Integration of computer aided device and finite element analysis can successfully stimulate the internal fixation of L3-IA visa posterior approach and observe the mechanic changes in the vertebral column more directly.

  7. Multidisciplinary approach of ectodermal dysplasia with implant retained fixed prosthesis

    Directory of Open Access Journals (Sweden)

    Vishnu Priya

    2013-01-01

    Full Text Available Ectodermal dysplasia represents a group of rare inherited conditions in which two or more ectodermally derived anatomical structures fail to develop. Early dental intervention can improve patient′s appearance, thereby minimizing associated emotional and psychological problems in these patients. Treatment requires a teamwork by medical personnel along with dental professionals of various specialties. Here, a rare case of a young female patient is presented with prosthetic management with implant supported fixed partial denture.

  8. Fixed points of quantum operations

    International Nuclear Information System (INIS)

    Arias, A.; Gheondea, A.; Gudder, S.

    2002-01-01

    Quantum operations frequently occur in quantum measurement theory, quantum probability, quantum computation, and quantum information theory. If an operator A is invariant under a quantum operation φ, we call A a φ-fixed point. Physically, the φ-fixed points are the operators that are not disturbed by the action of φ. Our main purpose is to answer the following question. If A is a φ-fixed point, is A compatible with the operation elements of φ? We shall show in general that the answer is no and we shall give some sufficient conditions under which the answer is yes. Our results will follow from some general theorems concerning completely positive maps and injectivity of operator systems and von Neumann algebras

  9. Fixed-point signal processing

    CERN Document Server

    Padgett, Wayne T

    2009-01-01

    This book is intended to fill the gap between the ""ideal precision"" digital signal processing (DSP) that is widely taught, and the limited precision implementation skills that are commonly required in fixed-point processors and field programmable gate arrays (FPGAs). These skills are often neglected at the university level, particularly for undergraduates. We have attempted to create a resource both for a DSP elective course and for the practicing engineer with a need to understand fixed-point implementation. Although we assume a background in DSP, Chapter 2 contains a review of basic theory

  10. Apparatus for fixing radioactive waste

    International Nuclear Information System (INIS)

    Murphy, J.D.; Pirro, J. Jr.; Lawrence, M.; Wisla, S.F.

    1975-01-01

    Fixing radioactive waste is disclosed in which the waste is collected as a slurry in aqueous media in a metering tank located within the nuclear facilities. Collection of waste is continued from time to time until a sufficient quantity of material to make up a full shipment to a burial ground has been collected. The slurry is then cast in shipping containers for shipment to a burial ground or the like by metering through a mixer into which fixing materials are simultaneously metered at a rate to yield the desired proportions of materials. (U.S.)

  11. Migration of a Broken Steinman Pin into the Posterior Compartment of the Leg 12 Years after Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Ali Birjandi Nejad

    2013-09-01

    Full Text Available This report is on a migration of a Steinman pin into the posterior com Department of the calf. It was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. The puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. Accord ing to our literature review, migration of fixation pins through the knee joint is an extremely rare occurrence and could be missed by an inattentive physician.  

  12. Posterior reversible encephalopathy syndrome: Some novel ...

    African Journals Online (AJOL)

    Two cases occurred following cerebral anoxia due to accidental strangulation and near-drowning, respectively. The third patient, a child known to have E-β thalassaemia, presented with transient encephalopathy following blood transfusion but involving the anterior brain rather than the posterior part classically described in ...

  13. Surgical site infection in posterior spine surgery

    African Journals Online (AJOL)

    2016-03-20

    Mar 20, 2016 ... Methodology: All consecutive patients who had posterior spine surgeries between January 2012 ... However, spinal instrumentation, surgery on cervical region and wound inspection on or ... While advances have been made in infection control ... costs, due to loss of productivity, patient dissatisfaction and.

  14. A posterior tibial tendon skipping rope

    NARCIS (Netherlands)

    van Sterkenburg, M. N.; Haverkamp, D.; van Dijk, C. N.; Kerkhoffs, G. M. M. J.

    2010-01-01

    This report presents an athletic patient with swelling and progressive pain on the posteromedial side of his right ankle on weight bearing. MRI demonstrated tenosynovitis and suspicion of a length rupture. On posterior tibial tendoscopy, there was no rupture, but medial from the tendon a tissue cord

  15. Hindfoot endoscopy for posterior ankle pain

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies, most of which can be diagnosed and treated with endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a longitudinal peroneus brevis rupture, peroneal tendon adhesiolysis, flexor hallucis longus release, os

  16. Posterior arch defects of the cervical spine

    International Nuclear Information System (INIS)

    Schwartz, A.M.; Wechsler, R.J.; Landy, M.D.; Wetzner, S.M.; Goldstein, S.A.

    1982-01-01

    Spondylolysis and absence of the pedicle are congenital anomalies of the posterior cervical spine. Their roentgenographic changes may be confused with other more serious entities which may necessitate either emergent therapy or require extensive diagnostic testing and treatment. Four cases are present and the literature is reviewed. A hypothesis for the embryologic etiology of these entities is proposed. (orig.)

  17. Frozen shoulder or missed posterior dislocation?

    African Journals Online (AJOL)

    initial diagnosis and management. ... D Leijnen,1,2 MD, MMed (Sports Med); J T Viljoen,1 BSc (Physio), MPhil (Exercise Sci); J H Kirby,1 MB ChB, MSc (Sports Med); ... diagnosis of posterior shoulder dislocation at the time of injury could.

  18. Restoration of the endodontically treated posterior tooth

    Directory of Open Access Journals (Sweden)

    Andrea Polesel

    2014-06-01

    Results and conclusions: Direct adhesive restorations, indirect bonded restorations and traditional full crown are three therapeutic options for the single posterior endodontically treated teeth. The amount of remaining sound tooth structure is the most significant factor influencing the therapeutic approach. The clinician's operative skill is a determining aspect for long-term success of adhesive inlays.

  19. Posterior arch defects of the cervical spine

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, A.M.; Wechsler, R.J.; Landy, M.D.; Wetzner, S.M.; Goldstein, S.A.

    1982-05-01

    Spondylolysis and absence of the pedicle are congenital anomalies of the posterior cervical spine. Their roentgenographic changes may be confused with other more serious entities which may necessitate either emergent therapy or require extensive diagnostic testing and treatment. Four cases are present and the literature is reviewed. A hypothesis for the embryologic etiology of these entities is proposed.

  20. Posterior reversible encephalopathy syndrome in patient

    African Journals Online (AJOL)

    abp

    2015-05-26

    May 26, 2015 ... reversible Posterior leukoencephalopathy syndrome [1, 2]. The. PRES is a clinical and radiological entity associating varying degrees, headaches, impaired consciousness, seizures and visual disturbances to neurological and radiological abnormalities of the parietal-occipital white matter [3]. PRES has a ...

  1. Extensive Supratentorial Hemorrhages Following Posterior Fossa ...

    African Journals Online (AJOL)

    Remote supratentorial hematoma soon after posterior fossa surgery for the removal of a space-occupying lesion is a rare but dramatic and dreaded complication, carrying significant morbidity and mortality. A 47-year-old woman presented with headache of 1-year duration that worsened over last 2 months, progressive ...

  2. Anterior versus posterior, and rim-rent rotator cuff tears: prevalence and MR sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Turnbull, J R; Orwin, J F [Wisconsin Univ., Madison, WI (United States). Dept. of Radiology

    1998-05-01

    Purpose. To determine the relative distribution of the locations of rotator cuff tears, and the sensitivity of anterior versus posterior tears on MR images. Patients and methods. We identified 110 consecutive patients who had a shoulder MR and either a partial-thickness or a small full-thickness rotator cuff tear diagnosed at arthroscopy. From the arthroscopy videotapes, we classified the tears as centered in the anterior or posterior half of the cuff, and as either in the critical zone or adjacent to the bony insertion. The original MR interpretation was compared with the arthroscopic findings. MR sensitivity and patient age were compared between patients with tears in the anterior and posterior halves of the cuff. In addition, in patients with partial tears less than 2 cm in diameter, an age comparison between those with tears in the critical zone and those with articular surface tears adjacent to the bony insertion (rim-rent tear) was performed. Results. The tear was centered in the anterior half of the rotator cuff in 79% of the patients younger than 36 years old, and in 89% of the patients 36 years old and over. The average age of the patients with tears in the anterior half (44 years) was not significantly different from the average age of those with posterior tears (40 years)(P=0.23). The sensitivity of MR for anterior tears was 0.69, and for posterior tears it was 0.56 (P=0.17). The average age of the 9 patients with rim-rent tears was 31 years, while that of the 28 patients with similarly-sized partial tears not involving the insertion was 40 years old (P=0.048). Five of the nine rim-rent tears (0.56) were interpreted correctly on the original MR report; two of the other tears were misinterpreted as intratendinous fluid but were diagnosable in retrospect. Conclusion. Even in patients less than 36 years old, most partial and small full-thickness rotator cuff tears are centered in the anterior half of the supraspinatus. Although our figure for MR sensitivity

  3. Imaging findings in posterior instability of the shoulder

    International Nuclear Information System (INIS)

    Harish, Srinivasan; Rebello, Ryan; O'Neill, John; Nagar, Arpit; Moro, Jaydeep; Pugh, David

    2008-01-01

    Posterior shoulder instability refers to the symptoms and signs resulting from excessive posterior translation of the humerus. Magnetic resonance (MR) imaging is the radiological modality of choice in the diagnostic assessment of posterior instability. Computed tomography (CT) is useful in the evaluation of osseous abnormalities associated with posterior instability. A detailed description of the posterior osseous and labroligamentous abnormalities has evolved recently, and many variant lesions of the posteroinferior labrum and/or capsular structures have been described. As the recommended surgical management of lesions associated with posterior instability is a lesion-specific approach, awareness of the specific lesions that have been described in association with posterior instability helps in pre-surgical planning. The purpose of this article is to review the classification of, and injury mechanisms leading to, posterior shoulder instability and to describe imaging findings associated with posterior instability, with emphasis on MR imaging. (orig.)

  4. Imaging findings in posterior instability of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Harish, Srinivasan; Rebello, Ryan; O' Neill, John [St. Joseph' s Healthcare, Department of Diagnostic Imaging, Hamilton, ON (Canada); McMaster University, Faculty of Health Sciences, Hamilton (Canada); Nagar, Arpit [St. Joseph' s Healthcare, Department of Diagnostic Imaging, Hamilton, ON (Canada); Moro, Jaydeep [St. Joseph' s Healthcare, Department of Orthopedic Surgery, Hamilton, ON (Canada); McMaster University, Faculty of Health Sciences, Hamilton (Canada); Pugh, David [Brantford General Hospital, Department of Orthopedic Surgery, Brantford, ON (Canada)

    2008-08-15

    Posterior shoulder instability refers to the symptoms and signs resulting from excessive posterior translation of the humerus. Magnetic resonance (MR) imaging is the radiological modality of choice in the diagnostic assessment of posterior instability. Computed tomography (CT) is useful in the evaluation of osseous abnormalities associated with posterior instability. A detailed description of the posterior osseous and labroligamentous abnormalities has evolved recently, and many variant lesions of the posteroinferior labrum and/or capsular structures have been described. As the recommended surgical management of lesions associated with posterior instability is a lesion-specific approach, awareness of the specific lesions that have been described in association with posterior instability helps in pre-surgical planning. The purpose of this article is to review the classification of, and injury mechanisms leading to, posterior shoulder instability and to describe imaging findings associated with posterior instability, with emphasis on MR imaging. (orig.)

  5. Flat Coalgebraic Fixed Point Logics

    Science.gov (United States)

    Schröder, Lutz; Venema, Yde

    Fixed point logics are widely used in computer science, in particular in artificial intelligence and concurrency. The most expressive logics of this type are the μ-calculus and its relatives. However, popular fixed point logics tend to trade expressivity for simplicity and readability, and in fact often live within the single variable fragment of the μ-calculus. The family of such flat fixed point logics includes, e.g., CTL, the *-nesting-free fragment of PDL, and the logic of common knowledge. Here, we extend this notion to the generic semantic framework of coalgebraic logic, thus covering a wide range of logics beyond the standard μ-calculus including, e.g., flat fragments of the graded μ-calculus and the alternating-time μ-calculus (such as ATL), as well as probabilistic and monotone fixed point logics. Our main results are completeness of the Kozen-Park axiomatization and a timed-out tableaux method that matches ExpTime upper bounds inherited from the coalgebraic μ-calculus but avoids using automata.

  6. Enumerating matroids of fixed rank

    NARCIS (Netherlands)

    Pendavingh, R.; van der Pol, J.

    2017-01-01

    It has been conjectured that asymptotically almost all matroids are sparse paving, i.e. that~s(n)∼m(n)s(n)∼m(n), where m(n)m(n) denotes the number of matroids on a fixed groundset of size nn, and s(n)s(n) the number of sparse paving matroids. In an earlier paper, we showed that

  7. Fixed Costs and Hours Constraints

    Science.gov (United States)

    Johnson, William R.

    2011-01-01

    Hours constraints are typically identified by worker responses to questions asking whether they would prefer a job with more hours and more pay or fewer hours and less pay. Because jobs with different hours but the same rate of pay may be infeasible when there are fixed costs of employment or mandatory overtime premia, the constraint in those…

  8. Adhesives for fixed orthodontic bands.

    Science.gov (United States)

    Millett, Declan T; Glenny, Anne-Marie; Mattick, Rye Cr; Hickman, Joy; Mandall, Nicky A

    2016-10-25

    Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. It has been shown that the quality of treatment result obtained with fixed appliances is much better than with removable appliances. Fixed appliances are, therefore, favoured by most orthodontists for treatment. The success of a fixed orthodontic appliance depends on the metal attachments (brackets and bands) being attached securely to the teeth so that they do not become loose during treatment. Brackets are usually attached to the front and side teeth, whereas bands (metal rings that go round the teeth) are more commonly used on the back teeth (molars). A number of adhesives are available to attach bands to teeth and it is important to understand which group of adhesives bond most reliably, as well as reducing or preventing dental decay during the treatment period. To evaluate the effectiveness of the adhesives used to attach bands to teeth during fixed appliance treatment, in terms of:(1) how often the bands come off during treatment; and(2) whether they protect the banded teeth against decay during fixed appliance treatment. The following electronic databases were searched: Cochrane Oral Health's Trials Register (searched 2 June 2016), Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 5) in the Cochrane Library (searched 2 June 2016), MEDLINE Ovid (1946 to 2 June 2016) and EMBASE Ovid (1980 to 2 June 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised and controlled clinical trials (RCTs and CCTs) (including split-mouth studies) of adhesives used to attach orthodontic bands to molar teeth were selected. Patients with full arch fixed orthodontic appliance(s) who had bands attached to molars were included. All review authors

  9. Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

    Science.gov (United States)

    Lei, Jianyin; Dong, Pengfei; Li, Zhiqiang; Zhu, Feng; Wang, Zhihua; Cai, Xianhua

    2017-05-01

    The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  10. Achieving an esthetic smile with fixed and removal prosthesis using extracoronal castable precision attachments

    Directory of Open Access Journals (Sweden)

    Sharad Vaidya

    2015-01-01

    Full Text Available Satisfactory restoration in a patient with a partially edentulous situation can be challenging especially when unilateral or bilateral posterior segment of teeth is missing. Successful restoration can be done with various conventional and contemporary treatment options. One such treatment modality is attachment-retained cast partial dentures. A key to success for an attachment retained cast partial denture is the strategic selection of teeth for retention. This clinical report discusses rehabilitation of a patient with the help of a combined prosthesis in the upper arch and stud retained overdenture in the lower arch.

  11. Posterior treatment of delayed traumatic atlantoaxial joint dislocation with apofix internal fixation

    International Nuclear Information System (INIS)

    Qing Wei; Jiang Weimin; Shi Jinhui; Li Xuefeng; Yang Huilin; Tang Tiansi

    2010-01-01

    Objective: To assess the effect of posterior fixation and fusion with Apofix device for the treatment of delayed traumatic atlantoaxial joint dislocation. Methods: Eighteen patients with delayed traumatic atlantoaxial joint dislocation were included. Posterior fixation and fusion with Apofix device were performed. First step was one or two week skull traction. After the atlantoaxial joint dislocation had been reduced, the posterior fixation and fusion with Apofix was performed. Using local anaesthesia, atlantoaxial interval and posterior structure of atlas and dentata were exposed by midline operative approach. Apofix interlaminar clamps were placed at posterior arch of atlas and odontoid vertebral laminae, autologous iliac bone graft was placed for fusion. Then the device to proper position was pressurized and items locked. Results: All of the patients were followed up, the mean follow-up period was 38 months (13 ∼ 84 months). Fifteen patients obtained complete reduction, the others were partial reduction. Seventeen patients had successful fusion after 3 or 4 months, only 1 patient who had partial reduction had internal fixation loose and nonfusion, leading to recurrence of atlantoaxial joint dislocation. An occipitocervical fusion surgery was performed on this patient. As to neurological assessment, 16 patients had neurological deficit before operation, while 6 of them recovered completely after operation, another 10 patients' neurological status improved significantly. JOA score was improved from 9.5 pre-operative to 15.8 post-operative. Conclusion: Apofix internal fixation and fusion seems to be feasible in treatment of delayed traumatic atlantoaxial joint dislocation. Successful reduction before operation and proper treatment after operation is also important. (authors)

  12. Late-onset Alzheimer disease genetic variants in posterior cortical atrophy and posterior AD.

    Science.gov (United States)

    Carrasquillo, Minerva M; Khan, Qurat ul Ain; Murray, Melissa E; Krishnan, Siddharth; Aakre, Jeremiah; Pankratz, V Shane; Nguyen, Thuy; Ma, Li; Bisceglio, Gina; Petersen, Ronald C; Younkin, Steven G; Dickson, Dennis W; Boeve, Bradley F; Graff-Radford, Neill R; Ertekin-Taner, Nilüfer

    2014-04-22

    To investigate association of genetic risk factors for late-onset Alzheimer disease (LOAD) with risk of posterior cortical atrophy (PCA), a syndrome of visual impairment with predominant Alzheimer disease (AD) pathology in posterior cortical regions, and with risk of "posterior AD" neuropathology. We assessed 81 participants with PCA diagnosed clinically and 54 with neuropathologic diagnosis of posterior AD vs 2,523 controls for association with 11 significant single nucleotide polymorphisms (SNPs) from published LOAD risk genome-wide association studies. There was highly significant association with APOE ε4 and increased risk of PCA (p = 0.0003, odds ratio [OR] = 3.17) and posterior AD (p = 1.11 × 10(-17), OR = 6.43). No other locus was significant after corrections for multiple testing, although rs11136000 near CLU (p = 0.019, OR = 0.60) and rs744373 near BIN1 (p = 0.025, OR = 1. 63) associated nominally significantly with posterior AD, and rs3851179 at the PICALM locus had significant association with PCA (p = 0.0003, OR = 2.84). ABCA7 locus SNP rs3764650, which was also tested under the recessive model because of Hardy-Weinberg disequilibrium, also had nominally significant association with PCA risk. The direction of association at APOE, CLU, and BIN1 loci was the same for participants with PCA and posterior AD. The effects for all SNPs, except rs3851179, were consistent with those for LOAD risk. We identified a significant effect for APOE and nominate CLU, BIN1, and ABCA7 as additional risk loci for PCA and posterior AD. Our findings suggest that at least some of the genetic risk factors for LOAD are shared with these atypical conditions and provide effect-size estimates for their future genetic studies.

  13. Posterior Mediastinal Tumors: Outcome of Surgery

    International Nuclear Information System (INIS)

    Abd Rahman, A.M.; Sedera, M.A.; Mourad, I.A.; Aziz, S.A.; Saber, T.K.H.; Al Sakary, M.A.

    2005-01-01

    The incidence of posterior mediastinal tumors relative to all tumors of the mediastinum is 23% to 30%. The posterior mediastinum is a potential space along each side of the vertebral column and adjacent proximal portion of the ribs. Primary tumors of posterior mediastinum are usually neurogenic. The aim of this study was to evaluate different surgical approaches used for the resection of posterior mediastinal tumors, and to assess morbidity, mortality and patients survival. Patients and Methods: Between January 200 I and January 2004, 30 patients with posterior mediastinal tumors were included. CT scan of the chest and CT guided biopsy were done for all patients; whereas MRI was done for suspected intraspinal extension. Posterolateral thoracotomy was the approach used in most of the patients. The Akwari approach was used in most of the patients with Dumbbell tumors. Neurogenic tumors constituted 67% of cases, being neuroblastoma in 60%. The non neurogenic tumors included a heterogenous group of rare tumors (n=10). Dumbbell tumors were found in 10 patients. Neuroblastoma was the commonest tumor to cause intraspinal extension (40%). Wide local excision was done in 13 patients; whereas extended resection was done in the remaining 17 patients. The mean intra-operative blood loss was 800cc and the mean hospital stay was 12 days. The size of the resected tumor ranged from 3X4cm to 30X22cm, 80% of tumors were malignant. Morbidity in relation to the procedures developed in 8 patients (atelectasis, meningitis, paraplegia, Horner syndrome and mild wound sepsis in 4, I, I, 1 and I of the patients; respectively). One postoperative mortality, due to meningitis was recorded. The overall survival by the end of three years was 87.7% with a mean survival of 30.4 months. The overall disease free survival was 55.9% with a mean disease free survival of 26.2 months. Posterior mediastinal tumors may reach large size before becoming symptomatic. Complete surgical excision (including

  14. Posterior Pole Sparing Laser Photocoagulation Combined with Intravitreal Bevacizumab Injection in Posterior Retinopathy of Prematurity

    Directory of Open Access Journals (Sweden)

    Rebecca Kim

    2014-01-01

    Full Text Available Purpose. To report the results of the posterior pole sparing laser photocoagulation combined with intravitreal bevacizumab injection (IVB in retinopathy of prematurity (ROP. Methods. A retrospective chart review of premature babies with ROP, all of whom received laser photocoagulation with IVB. Eleven eyes of 6 infants with advanced zone I ROP underwent laser ablation sparing posterior pole with concurrent IVB. The results were compared with those of full-laser treatment combined with IVB to 8 eyes of 5 infants with advanced ROP without involvement of the posterior pole. Results. The posterior pole sparing laser with IVB was performed with zone I, stage 3+ ROP at the mean postmenstrual age of 36 weeks and 5 days. The plus sign decreased significantly at postoperative day 1, the neovascular proliferation regressed by postoperative week 1, and the normal vascularization started at postoperative day 32 on the average. Two months after treatment, vascularization of the spared avascular area was completed. There was no macular dragging, tractional retinal detachment, foveal destruction by laser scars, or any other adverse event. No significant anatomical differences were identified from those of full-laser ablation combined with IVB. Conclusions. Posterior pole sparing laser with IVB can give favorable results without destruction of posterior pole retina.

  15. Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.

    Science.gov (United States)

    Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D

    2007-09-01

    Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was

  16. Computation of posterior distribution in Bayesian analysis – application in an intermittently used reliability system

    Directory of Open Access Journals (Sweden)

    V. S.S. Yadavalli

    2002-09-01

    Full Text Available Bayesian estimation is presented for the stationary rate of disappointments, D∞, for two models (with different specifications of intermittently used systems. The random variables in the system are considered to be independently exponentially distributed. Jeffreys’ prior is assumed for the unknown parameters in the system. Inference about D∞ is being restrained in both models by the complex and non-linear definition of D∞. Monte Carlo simulation is used to derive the posterior distribution of D∞ and subsequently the highest posterior density (HPD intervals. A numerical example where Bayes estimates and the HPD intervals are determined illustrates these results. This illustration is extended to determine the frequentistical properties of this Bayes procedure, by calculating covering proportions for each of these HPD intervals, assuming fixed values for the parameters.

  17. Rehabilitation of Posterior Maxilla with Zygomatic and Dental Implant after Tumor Resection: A Case Report

    Directory of Open Access Journals (Sweden)

    Faysal Ugurlu

    2013-01-01

    Full Text Available Zygomatic implants have been used for dental rehabilitation in patients with insufficient bone in the posterior upper jaw, due to, for example, tumor resection, trauma, or atrophy. Zygomatic implants are an alternative to complex free or vascularized bone grafting and distraction osteogenesis. A 42-year-old male patient with a severe defect in the right posterior maxilla, starting from the first canine region, which had occurred after tumor resection 3 years earlier, was referred to our department. One zygomatic implant (Brenemark System, Nobel Biocare, Goteborg, Sweden to the zygoma and one dental implant to the canine region were placed. After a 5-month osseointegration period, a fixed denture was fabricated and adapted to the implants. Although the surgical and prosthetic procedures for zygoma implants are not easy, the final outcomes can be successful with appropriate planning.

  18. T-Fix endoscopic meniscal repair: technique and approach to different types of tears.

    Science.gov (United States)

    Barrett, G R; Richardson, K; Koenig, V

    1995-04-01

    Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.

  19. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Konkuk University Hospital, Department of Radiology, Seoul (Korea); Kim, Sam Soo; Han, Heon [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Kang, Hyun-Seung [Konkuk University Hospital, Department of Neurosurgery, Seoul (Korea); Moon, Won-Jin [Konkuk University Hospital, Department of Radiology, Seoul (Korea); Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  20. Posterior reversible encephalopathy syndrome: A case report

    Directory of Open Access Journals (Sweden)

    Kostić Dejan

    2015-01-01

    Full Text Available Posterior reversible encephalopathy syndrome (PRES is characterized by the following symptoms: seizures, impaired consciousness and/or vision, vomiting, nausea, and focal neurological signs. Diagnostic imaging includes examination by magnetic resonance (MR and computed tomography (CT, where brain edema is visualized bi-laterally and symmetrically, predominantly posteriorly, parietally, and occipitally. Case report. We presented a 73-year-old patient with the years-long medical history of hipertension and renal insufficiency, who developed PRES with the symptomatology of the rear cranium. CT and MR verified changes in the white matter involving all lobes on both sides of the brain. After a two-week treatment (antihypertensive, hypolipemic and rehydration therapy clinical improvement with no complications occurred, with complete resolution of changes in the white matter observed on CT and MR. Conclusion. PRES is a reversible syndrome in which the symptoms withdraw after several days to several weeks if early diagnosis is made and appropriate treatment started without delay.

  1. Visual Dysfunction in Posterior Cortical Atrophy

    Science.gov (United States)

    Maia da Silva, Mari N.; Millington, Rebecca S.; Bridge, Holly; James-Galton, Merle; Plant, Gordon T.

    2017-01-01

    Posterior cortical atrophy (PCA) is a syndromic diagnosis. It is characterized by progressive impairment of higher (cortical) visual function with imaging evidence of degeneration affecting the occipital, parietal, and posterior temporal lobes bilaterally. Most cases will prove to have Alzheimer pathology. The aim of this review is to summarize the development of the concept of this disorder since it was first introduced. A critical discussion of the evolving diagnostic criteria is presented and the differential diagnosis with regard to the underlying pathology is reviewed. Emphasis is given to the visual dysfunction that defines the disorder, and the classical deficits, such as simultanagnosia and visual agnosia, as well as the more recently recognized visual field defects, are reviewed, along with the evidence on their neural correlates. The latest developments on the imaging of PCA are summarized, with special attention to its role on the differential diagnosis with related conditions. PMID:28861031

  2. Shining a light on posterior cortical atrophy.

    Science.gov (United States)

    Crutch, Sebastian J; Schott, Jonathan M; Rabinovici, Gil D; Boeve, Bradley F; Cappa, Stefano F; Dickerson, Bradford C; Dubois, Bruno; Graff-Radford, Neill R; Krolak-Salmon, Pierre; Lehmann, Manja; Mendez, Mario F; Pijnenburg, Yolande; Ryan, Natalie S; Scheltens, Philip; Shakespeare, Tim; Tang-Wai, David F; van der Flier, Wiesje M; Bain, Lisa; Carrillo, Maria C; Fox, Nick C

    2013-07-01

    Posterior cortical atrophy (PCA) is a clinicoradiologic syndrome characterized by progressive decline in visual processing skills, relatively intact memory and language in the early stages, and atrophy of posterior brain regions. Misdiagnosis of PCA is common, owing not only to its relative rarity and unusual and variable presentation, but also because patients frequently first seek the opinion of an ophthalmologist, who may note normal eye examinations by their usual tests but may not appreciate cortical brain dysfunction. Seeking to raise awareness of the disease, stimulate research, and promote collaboration, a multidisciplinary group of PCA research clinicians formed an international working party, which had its first face-to-face meeting on July 13, 2012 in Vancouver, Canada, prior to the Alzheimer's Association International Conference. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  3. Visual Dysfunction in Posterior Cortical Atrophy

    Directory of Open Access Journals (Sweden)

    Mari N. Maia da Silva

    2017-08-01

    Full Text Available Posterior cortical atrophy (PCA is a syndromic diagnosis. It is characterized by progressive impairment of higher (cortical visual function with imaging evidence of degeneration affecting the occipital, parietal, and posterior temporal lobes bilaterally. Most cases will prove to have Alzheimer pathology. The aim of this review is to summarize the development of the concept of this disorder since it was first introduced. A critical discussion of the evolving diagnostic criteria is presented and the differential diagnosis with regard to the underlying pathology is reviewed. Emphasis is given to the visual dysfunction that defines the disorder, and the classical deficits, such as simultanagnosia and visual agnosia, as well as the more recently recognized visual field defects, are reviewed, along with the evidence on their neural correlates. The latest developments on the imaging of PCA are summarized, with special attention to its role on the differential diagnosis with related conditions.

  4. Posterior sternoclavicular dislocation: an American football injury

    DEFF Research Database (Denmark)

    Marker, L B; Klareskov, B

    1996-01-01

    Posterior dislocation of the sternoclavicular joint is uncommon, accounting for less than 0.1% of all dislocations. Since 1824 a little more than 100 cases have been reported, and the majority in the past 20 years. A review of published reports suggests that this injury is seen particularly in co...... in connection with American football. A typical case is described. The importance of this injury is that there is often a delay in diagnosis with potentially serious complications....

  5. Complications in posterior lumbar interbody fusion

    OpenAIRE

    Kreuzer, Rolf-Peter

    2010-01-01

    From 1993 to 2000, 220 consecutive patients with unstable degenerative spondylolisthesis were studied after posterior lumbar interbody fusion (PLIF) using different types of grafts and pedicle screw systems. In a retrospective review the author detail the associated complications and their correlation with perioperative factors. The causes, strategies for their avoidance, and the clinical course of these complications are also disscused. The study group was composed of 136 women and 84 men...

  6. Reversible Posterior Leukoencephalopathy Syndrome Induced by Pazopanib

    Directory of Open Access Journals (Sweden)

    Chelis Leonidas

    2012-10-01

    Full Text Available Abstract Background The reversible posterior leukoencephalopathy syndrome is a clinical/radiological syndrome characterized by headache, seizures, impaired vision, acute hypertension, and typical magnetic resonance imaging findings. There are several reports in the literature that depict its occurrence in cancer patients. The list of common anticancer and supportive care drugs that predispose to reversible posterior leukoencephalopathy syndrome is expanding and includes not only a large number of chemotherapeutic agents but also an increased number of new targeted drugs, particularly angiogenesis inhibitors such as bevacizumab,sorefenib and sunitinib. Pazopanib is an oral tyrosine kinase inhibitor targeting vascular endothelial growth factor receptor, platelet-derived growth factor receptor, and c-Kit which after a positive phase III randomized clinical trial in patients with advanced renal cell cancer received FDA approval for the treatment of advanced renal cell carcinoma. Until now no cases of reversible posterior leukoencephalopathy syndrome induced by pazopanib have been reported. Case report We present the case of a 40 years old female patient with heavily pre-treated metastatic renal cell carcinoma who received pazopanib as salvage treatment. After 21 days of pazopanib therapy the patient referred to the emergency department with epileptic seizure, impaired vision at both eyes and headache. MRI of the brain revealed subcortical oedema at the occipital and parietal lobes bilaterally. She was treated with anticonvulsants, i.v. administration of mannitol and antihypertensives and she recovered completely from her symptoms and was discharged on the tenth hospital day. A brain MRI performed 3 weeks after showed that the subcortical oedema had been subsided. Conclusion In conclusion this is the first case of pazopanib induced reversible posterior leukoencephalopathy syndrome. Although usually reversible, this syndrome is a serious and

  7. Cervical disc hernia operations through posterior laminoforaminotomy.

    Science.gov (United States)

    Yolas, Coskun; Ozdemir, Nuriye Guzin; Okay, Hilmi Onder; Kanat, Ayhan; Senol, Mehmet; Atci, Ibrahim Burak; Yilmaz, Hakan; Coban, Mustafa Kemal; Yuksel, Mehmet Onur; Kahraman, Umit

    2016-01-01

    The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years). Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%). On control examinations, there was no finding of instability or cervical kyphosis. Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis.

  8. Cervical disc hernia operations through posterior laminoforaminotomy

    Directory of Open Access Journals (Sweden)

    Coskun Yolas

    2016-01-01

    Full Text Available Objective: The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. Materials and Methods: We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. Results: The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years. Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%. On control examinations, there was no finding of instability or cervical kyphosis. Conclusion: Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis.

  9. Primary posterior perineal herniation of urinary bladder

    Directory of Open Access Journals (Sweden)

    Kurumboor Prakash

    2013-01-01

    Full Text Available Primary perineal hernia is a rare clinical condition wherein herniation of viscera occurs through pelvic diaphragm. They are usually mistaken for sciatic hernia, rectal prolapse or other diseases in the perineum. Correct identification of the type of hernia by imaging is crucial for planning treatment. We present a case of primary posterior herniation of urinary bladder and rectal wall through levator ani repaired laparoscopically using a mesh repair.

  10. Posterior midline cervical fetal cystic hygroma.

    Directory of Open Access Journals (Sweden)

    Oak S

    1992-04-01

    Full Text Available Posterior midline cervical cystic hygromas (PMC are frequently found associated with chromosomal aberrations and usually do not survive. The present report illustrates diagnosis of this condition by sonography in an 18 weeks old fetus and an amniocentesis revealed 45 x0 karyotype and increased concentration of alpha-fetoproteins. Pregnancy was terminated in view of Turner′s syndrome. The etiology and natural history of the condition is reviewed.

  11. Reversible Posterior Leukoencephalopathy Syndrome Induced by Pazopanib

    International Nuclear Information System (INIS)

    Chelis, Leonidas; Kakolyris, Stylianos; Souftas, Vasilios; Amarantidis, Kiriakos; Xenidis, Nikolaos; Chamalidou, Eleni; Dimopoulos, Prokopios; Michailidis, Prodromos; Christakidis, Evagelos; Prassopoulos, Panagiotis

    2012-01-01

    The reversible posterior leukoencephalopathy syndrome is a clinical/radiological syndrome characterized by headache, seizures, impaired vision, acute hypertension, and typical magnetic resonance imaging findings. There are several reports in the literature that depict its occurrence in cancer patients. The list of common anticancer and supportive care drugs that predispose to reversible posterior leukoencephalopathy syndrome is expanding and includes not only a large number of chemotherapeutic agents but also an increased number of new targeted drugs, particularly angiogenesis inhibitors such as bevacizumab,sorefenib and sunitinib. Pazopanib is an oral tyrosine kinase inhibitor targeting vascular endothelial growth factor receptor, platelet-derived growth factor receptor, and c-Kit which after a positive phase III randomized clinical trial in patients with advanced renal cell cancer received FDA approval for the treatment of advanced renal cell carcinoma. Until now no cases of reversible posterior leukoencephalopathy syndrome induced by pazopanib have been reported. We present the case of a 40 years old female patient with heavily pre-treated metastatic renal cell carcinoma who received pazopanib as salvage treatment. After 21 days of pazopanib therapy the patient referred to the emergency department with epileptic seizure, impaired vision at both eyes and headache. MRI of the brain revealed subcortical oedema at the occipital and parietal lobes bilaterally. She was treated with anticonvulsants, i.v. administration of mannitol and antihypertensives and she recovered completely from her symptoms and was discharged on the tenth hospital day. A brain MRI performed 3 weeks after showed that the subcortical oedema had been subsided. In conclusion this is the first case of pazopanib induced reversible posterior leukoencephalopathy syndrome. Although usually reversible, this syndrome is a serious and potentially life threatening adverse effect, if untreated, that should

  12. Cyclosporine-related reversible posterior leukoencephalopathy: MRI

    International Nuclear Information System (INIS)

    Jarosz, J.M.; Howlett, D.C.; Cox, T.C.S.; Bingham, J.B.

    1997-01-01

    Three patients aged 48, 11 and 40 years, two of whom were recent recipients of renal transplants and one of a bone marrow transplant, developed seizures, with cortical blindness in two cases. All were immunosuppressed with cyclosporine and were hypertensive at the onset of symptoms. MRI showed predominantly posterior signal changes in all three cases. The abnormalities were more conspicuous on fast FLAIR images than on conventional T2-weighted spin-echo images. (orig.). With 4 figs

  13. A fractographic study of clinically retrieved zirconia–ceramic and metal–ceramic fixed dental prostheses

    OpenAIRE

    Pang, Zhen; Chughtai, Asima; Sailer, Irena; Zhang, Yu

    2015-01-01

    A recent 3-year randomized controlled trial (RCT) of tooth supported three- to five-unit zirconia-ceramic and metal-ceramic posterior fixed dental prostheses (FDPs) revealed that veneer chipping and fracture in zirconia-ceramic systems occurred more frequently than those in metal-ceramic systems [1]. This study seeks to elucidate the underlying mechanisms responsible for the fracture phenomena observed in this RCT using a descriptive fractographic analysis

  14. Fixed target flammable gas upgrades

    International Nuclear Information System (INIS)

    Schmitt, R.; Squires, B.; Gasteyer, T.; Richardson, R.

    1996-12-01

    In the past, fixed target flammable gas systems were not supported in an organized fashion. The Research Division, Mechanical Support Department began to support these gas systems for the 1995 run. This technical memo describes the new approach being used to supply chamber gasses to fixed target experiments at Fermilab. It describes the engineering design features, system safety, system documentation and performance results. Gas mixtures provide the medium for electron detection in proportional and drift chambers. Usually a mixture of a noble gas and a polyatomic quenching gas is used. Sometimes a small amount of electronegative gas is added as well. The mixture required is a function of the specific chamber design, including working voltage, gain requirements, high rate capability, aging and others. For the 1995 fixed target run all the experiments requested once through gas systems. We obtained a summary of problems from the 1990 fixed target run and made a summary of the operations logbook entries from the 1991 run. These summaries primarily include problems involving flammable gas alarms, but also include incidents where Operations was involved or informed. Usually contamination issues were dealt with by the experimenters. The summaries are attached. We discussed past operational issues with the experimenters involved. There were numerous incidents of drift chamber failure where contaminated gas was suspect. However analyses of the gas at the time usually did not show any particular problems. This could have been because the analysis did not look for the troublesome component, the contaminant was concentrated in the gas over the liquid and vented before the sample was taken, or that contaminants were drawn into the chambers directly through leaks or sub-atmospheric pressures. After some study we were unable to determine specific causes of past contamination problems, although in argon-ethane systems the problems were due to the ethane only

  15. A fixed-point farrago

    CERN Document Server

    Shapiro, Joel H

    2016-01-01

    This text provides an introduction to some of the best-known fixed-point theorems, with an emphasis on their interactions with topics in analysis. The level of exposition increases gradually throughout the book, building from a basic requirement of undergraduate proficiency to graduate-level sophistication. Appendices provide an introduction to (or refresher on) some of the prerequisite material and exercises are integrated into the text, contributing to the volume’s ability to be used as a self-contained text. Readers will find the presentation especially useful for independent study or as a supplement to a graduate course in fixed-point theory. The material is split into four parts: the first introduces the Banach Contraction-Mapping Principle and the Brouwer Fixed-Point Theorem, along with a selection of interesting applications; the second focuses on Brouwer’s theorem and its application to John Nash’s work; the third applies Brouwer’s theorem to spaces of infinite dimension; and the fourth rests ...

  16. Management of Posterior Urethral Valves in Rural Kenya

    African Journals Online (AJOL)

    Management of Posterior Urethral Valves in Rural. Kenya .... Antwi S. Audit of Posterior Urethral Valve (PUV) in Children at ... Community Paediatrics Committee, Infectious. Diseases ... Effect of Circumcision on Risk of Urinary Tract. Infection in ...

  17. More on PT-Symmetry in (Generalized Effect Algebras and Partial Groups

    Directory of Open Access Journals (Sweden)

    J. Paseka

    2011-01-01

    Full Text Available We continue in the direction of our paper on PT-Symmetry in (Generalized Effect Algebras and Partial Groups. Namely we extend our considerations to the setting of weakly ordered partial groups. In this setting, any operator weakly ordered partial group is a pasting of its partially ordered commutative subgroups of linear operators with a fixed dense domain over bounded operators. Moreover, applications of our approach for generalized effect algebras are mentioned.

  18. Hyperbolic partial differential equations

    CERN Document Server

    Witten, Matthew

    1986-01-01

    Hyperbolic Partial Differential Equations III is a refereed journal issue that explores the applications, theory, and/or applied methods related to hyperbolic partial differential equations, or problems arising out of hyperbolic partial differential equations, in any area of research. This journal issue is interested in all types of articles in terms of review, mini-monograph, standard study, or short communication. Some studies presented in this journal include discretization of ideal fluid dynamics in the Eulerian representation; a Riemann problem in gas dynamics with bifurcation; periodic M

  19. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  20. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2011-01-01

    A rigorous, yet accessible, introduction to partial differential equations-updated in a valuable new edition Beginning Partial Differential Equations, Second Edition provides a comprehensive introduction to partial differential equations (PDEs) with a special focus on the significance of characteristics, solutions by Fourier series, integrals and transforms, properties and physical interpretations of solutions, and a transition to the modern function space approach to PDEs. With its breadth of coverage, this new edition continues to present a broad introduction to the field, while also addres

  1. Non-surgical Management of Skeletal Class III Malocclusion with Bilateral Posterior Crossbite: A Case Report.

    Science.gov (United States)

    Kumari, Lalima; Nayan, Kamal

    2016-12-01

    A 16-year-old female patient with skeletal Class III malocclusion and bilateral posterior cross bite complaining of difficulty in chewing was treated orthodontically without surgery (camouflage treatment). The treatment comprised of fixed orthodontic treatment with MBT prescription (0.022˝×0.028˝ slot) using quad helix appliance for bilateral expansion of maxillary arch and Class III elastics for occlusal correction. Post-treatment records showed normal overbite and overjet with acceptable occlusion. So with this treatment strategy of expanding the maxillary arch using a quad helix appliance and use of Class III elastics, we achieved a good result with optimal occlusion.

  2. Nueva indicación de implantes cigomáticos para la rehabilitación fija de desdentados parciales: reporte de un caso A new indication for Zygomatic implants for the fixed rehabilitation of the partially edentulous patient: Case report

    Directory of Open Access Journals (Sweden)

    M.F. Pintor Willcock

    2007-08-01

    Full Text Available Los implantes cigomáticos están indicados en casos de reabsorciones maxilares severas. Esto permitiría eliminar la necesidad de injertos óseos o levantamientos de seno de manera de recuperar el volumen óseo necesario para rehabilitar en base a implantes convencionales, disminuyendo así la morbilidad y el tiempo de tratamiento. A continuación presentamos caso de paciente desdentado parcial superior, clase I de Kennedy, en el cual se utilizaron dos implantes cigomáticos a cada lado, emergiendo sobre el reborde, a través de una modificación de la técnica.Zygomatic Implants are used in the rehabilitation of severely resorbed maxillas. This eliminates the necessity of bone grafting or sinus augmentation to restore the osseous volume necessary for conventional implant rehabilitation. This also minimizes morbidity and treatment times. We present the case of a patient with a partially edentulous upper ridge, Kennedy class I, in whom two zygomatic implants were placed in each side, that emerged over the alveolar ridge crest as a result of a technique modification.

  3. Convergence of posteriors for discretized log Gaussian Cox processes

    DEFF Research Database (Denmark)

    Waagepetersen, Rasmus Plenge

    2004-01-01

    In Markov chain Monte Carlo posterior computation for log Gaussian Cox processes (LGCPs) a discretization of the continuously indexed Gaussian field is required. It is demonstrated that approximate posterior expectations computed from discretized LGCPs converge to the exact posterior expectations...... when the cell sizes of the discretization tends to zero. The effect of discretization is studied in a data example....

  4. Diagnostic Accuracy of 2-Dimensional Computed Tomography for Articular Involvement and Fracture Pattern of Posterior Malleolar Fractures.

    Science.gov (United States)

    Meijer, Diederik T; de Muinck Keizer, Robert-Jan O; Doornberg, Job N; Sierevelt, Inger N; Stufkens, Sjoerd A; Kerkhoffs, Gino M M J; van Dijk, C Niek

    2016-01-01

    Up to 44% of ankle fractures have involvement of the posterior tibial margin. Fracture size and morphology are important factors to guide treatment of these fragments, but reliability of plain radiography in estimating size is low. The aim of the current study was to evaluate the accuracy of 2-dimensional computed tomography (2DCT) in the assessment of posterior malleolar fractures. Additionally, the diagnostic accuracy of 2DCT and its value in preoperative planning was evaluated. Thirty-one patients with 31 ankle fractures including a posterior malleolar fragment were selected. Preoperative CT scans were analyzed by 50 observers from 23 countries. Quantitative 3-dimensional CT (Q3DCT) reconstructions were used as a reference standard. Articular involvement of the posterior fragment was overestimated on 2DCT by factors 1.6, 1.4, and 2.2 for Haraguchi types I, II, and III, respectively. Interobserver agreement on operative management ("to fix, or not to fix?") was substantial (κ = 0.69) for Haraguchi type I fractures, fair (κ = 0.23) for type II fractures, and poor (κ = 0.09) for type III fractures. 2DCT images led to a change in treatment of the posterior malleolus in 23% of all fractures. Surgeons would operatively treat type I fractures in 63%, type II fractures in 67%, and type III fractures in 22%. Surgeons overestimated true articular involvement of posterior malleolar fractures on 2DCT scans. 2DCT showed some additional value in estimating the involved articular surface when compared to plain radiographs; however, this seemed not yet sufficient to accurately read the fractures. Analysis of the CT images showed a significant influence on choice of treatment in 23% with a shift toward operative treatment in 12% of cases compared to evaluating plain lateral radiographs alone. Level III, comparative study. © The Author(s) 2015.

  5. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  6. OUR EXPERINCE WITH USE OF POSTERIOR MESH RECTOPEXY IN COMPLETE RECTAL PROLAPSE

    Directory of Open Access Journals (Sweden)

    Sudhansu Sekhar Mohanty

    2017-12-01

    Full Text Available BACKGROUND Mesh rectopexy is one of the accepted treatment options for rectal prolapse. We used polypropylene posterior mesh rectopexy for prolapse rectum. The aim of the study was to see demographic, clinical and functional outcome of posterior mesh rectopexy in our setup. MATERIALS AND METHODS The case report of 33 patients under gone posterior abdominal mesh rectopexy in MKCG medical college and hospital from 1st July 2012 to 1st July 2017 were reviewed retrospectively and the patients were followed up in surgical OPD/telephonic questionnaire. All patients had undergone standard posterior abdominal mesh rectopexy without the division of lateral ligaments with utmost care for prevention of bleeding and nerve damage. RESULTS Out of 33 cases of abdominal rectopexy, 12 (36% were males and 21 (64% were females. 27 (82% were within 61-80 years of age group. The most common symptoms were mass per annum (100% followed by incontinence for liquid stool and flatus 24 (72%. There was no operative mortality. The average hospital stay 7.8 days (5-11 days. The constipation (p=0.019 and incontinence (p=0.0165 were better postoperatively. There was 1 (3% partial recurrence of rectal prolapse in 91-year-old lady in 2 years follow up. CONCLUSION The recurrence rate as well as clinical and functional outcome of open abdominal mesh rectopexy seems to be satisfactory, however, long-term effect has to be seen.

  7. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2014-01-01

    A broad introduction to PDEs with an emphasis on specialized topics and applications occurring in a variety of fields Featuring a thoroughly revised presentation of topics, Beginning Partial Differential Equations, Third Edition provides a challenging, yet accessible,combination of techniques, applications, and introductory theory on the subjectof partial differential equations. The new edition offers nonstandard coverageon material including Burger's equation, the telegraph equation, damped wavemotion, and the use of characteristics to solve nonhomogeneous problems. The Third Edition is or

  8. Breakdown localization in the fixed gap system

    CERN Document Server

    Rajamaki, Robin; Wuensch, Walter

    2014-01-01

    Accurate localization of breakdowns in vacuum could help shed light on breakdown related processes that are not yet fully understood. At the DC spark lab at CERN, an instrument called the Fixed Gap System (FGS) has been developed partially for this purpose. Among other things, the FGS has four built-in antennas, which are intended for breakdown localization. The capability of this aspect of the FGS was explored in this report. Specifically, the feasibility of using a method similar to that which is used in cavity Beam Position Monitors (BPMs) was investigated. The usable frequency range of the current experimental setup was also studied. Firstly, a modal analysis of the inner geometry of the FGS was done in HFSS. This showed that the two first modes to be expected in the spark gap quite differ from those of the ideal pillbox – both in field pattern and in frequency ( 4 and 6 GHz vs. 0.2 and 3 GHz). Secondly, S-parameters of the system were measured. These showed that the coupling between antennas is weak...

  9. The use of implants as retainers for removable partial dentures.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Shapiro, Herbert J

    2010-01-01

    There has been little presented in the literature regarding the use of implant bodies as retainers for removable partial dentures. However, these fixtures can be a useful asset for restorative dentists, as they can be used when there is insufficient bone for a fixed prosthesis or as retainers for a provisional appliance until additional dental treatment is possible.

  10. Adhesives for fixed orthodontic brackets.

    Science.gov (United States)

    Mandall, N A; Millett, D T; Mattick, C R; Hickman, J; Macfarlane, T V; Worthington, H V

    2003-01-01

    Bonding of orthodontic brackets to teeth is important to enable effective and efficient treatment with fixed appliances. The problem is bracket failure during treatment which increases operator chairside time and lengthens treatment time. A prolonged treatment is likely to increase the oral health risks of orthodontic treatment with fixed appliances one of which is irreversible enamel decalcification. To evaluate the effectiveness of different orthodontic adhesives for bonding. Electronic databases: the Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE. Date of most recent searches: August 2002 (CENTRAL) (The Cochrane Library Issue 2, 2002). Trials were selected if they met the following criteria: randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing two different adhesive groups. Participants were patients with fixed orthodontic appliances. The interventions were adhesives that bonded stainless steel brackets to all teeth except the molars. The primary outcome was debond or bracket failure. Data were recorded on decalcification as a secondary outcome, if present. Information regarding methods, participants, interventions, outcome measures and results were extracted in duplicate by pairs of reviewers (Nicky Mandall (NM) and Rye Mattick (CRM); Declan Millett (DTM) and Joy Hickman (JH2)). Since the data were not presented in a form that was amenable to meta-analysis, the results of the review are presented in narrative form only. Three trials satisfied the inclusion criteria. A chemical cured composite was compared with a light cure composite (one trial), a conventional glass ionomer cement (one trial) and a polyacid-modified resin composite (compomer) (one trial). The quality of the trial reports was generally poor. It is difficult to draw any conclusions from this review, however, suggestions are made for methods of improving future research involving

  11. BRST gauge fixing and regularization

    International Nuclear Information System (INIS)

    Damgaard, P.H.; Jonghe, F. de; Sollacher, R.

    1995-05-01

    In the presence of consistent regulators, the standard procedure of BRST gauge fixing (or moving from one gauge to another) can require non-trivial modifications. These modifications occur at the quantum level, and gauges exist which are only well-defined when quantum mechanical modifications are correctly taken into account. We illustrate how this phenomenon manifests itself in the solvable case of two-dimensional bosonization in the path-integral formalism. As a by-product, we show how to derive smooth bosonization in Batalin-Vilkovisky Lagrangian BRST quantization. (orig.)

  12. GOLD and the fixed ratio

    Directory of Open Access Journals (Sweden)

    Vestbo J

    2012-09-01

    Full Text Available Jørgen VestboUniversity of Manchester, Manchester, UKI read with interest the paper entitled "Diagnosis of airway obstruction in the elderly: contribution of the SARA study" by Sorino et al in a recent issue of this journal.1 Being involved in the Global Initiative for Obstructive Lung Diseases (GOLD, it is nice to see the interest sparked by the GOLD strategy document. However, in the paper by Sorino et al, there are a few misunderstandings around GOLD and the fixed ratio (forced expiratory volume in 1 second/forced volume vital capacity < 0.70 that need clarification.View original paper by Sorino and colleagues.

  13. Fracture analysis of randomized implant-supported fixed dental prostheses

    Science.gov (United States)

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and

  14. Nonlinear partial differential equations of second order

    CERN Document Server

    Dong, Guangchang

    1991-01-01

    This book addresses a class of equations central to many areas of mathematics and its applications. Although there is no routine way of solving nonlinear partial differential equations, effective approaches that apply to a wide variety of problems are available. This book addresses a general approach that consists of the following: Choose an appropriate function space, define a family of mappings, prove this family has a fixed point, and study various properties of the solution. The author emphasizes the derivation of various estimates, including a priori estimates. By focusing on a particular approach that has proven useful in solving a broad range of equations, this book makes a useful contribution to the literature.

  15. Nonlinear elliptic partial differential equations an introduction

    CERN Document Server

    Le Dret, Hervé

    2018-01-01

    This textbook presents the essential parts of the modern theory of nonlinear partial differential equations, including the calculus of variations. After a short review of results in real and functional analysis, the author introduces the main mathematical techniques for solving both semilinear and quasilinear elliptic PDEs, and the associated boundary value problems. Key topics include infinite dimensional fixed point methods, the Galerkin method, the maximum principle, elliptic regularity, and the calculus of variations. Aimed at graduate students and researchers, this textbook contains numerous examples and exercises and provides several comments and suggestions for further study.

  16. MRI of the fetal posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Adamsbaum, Catherine; Andre, Christine; Merzoug, Valerie; Ferey, Solene [St Vincent de Paul Hospital, Department of Radiology, Paris Cedex 14 (France); Moutard, Marie Laure [St Vincent de Paul Hospital, Department of Neuropaediatrics, Paris (France); Quere, Marie Pierre [CHU, Department of Radiology, Nantes (France); Lewin, Fanny [St Vincent de Paul Hospital, Maternity Department, Paris (France); Fallet-Bianco, Catherine [Ste Anne Hospital, Department of Neuropathology, Paris (France)

    2005-02-01

    MRI is a useful tool to complement US for imaging of the fetal posterior fossa (PF). In France, the discovery of a PF malformation in the fetus frequently leads to termination of pregnancy (80% in a personal series). However, despite improved accuracy in the diagnosis of PF abnormalities, prognosis remains uncertain. The first objective of this review is to document the normal MRI landmarks of the developing fetal PF. Because of their thinness, the visibility of the cerebellar fissures is dramatically delayed on MRI compared to macroscopic data. An important landmark is identification of the primary fissure of the vermis, normally seen at around 25-26 weeks' gestation (WG) on the sagittal slice, separating the larger posterior lobe from the anterior lobe (volume ratio around 2:1). The prepyramidal and secondary fissures are usually only identifiable after 32 WG and the hemispheric fissures are difficult to see until the end of pregnancy. Considering the signal changes, high signal on T2-weighted (T2-W) sequences is seen from 25 WG in the posterior part of the brain stem (tegmentum and ascending sensory tracts) related to myelination. The low signal intensities seen within the cerebellum on T2-W images correspond to high cellularity of grey matter (deep nuclei), as there is no myelination within the white matter before 38 WG. The second objective is to highlight the signs highly predictive of a poor neurological prognosis. Lack of pontine curvature or vermian agenesis without a PF cyst (small volume of PF) is greatly associated with poor neurological status. The third objective is to propose a diagnostic strategy in difficult cases where prognosis is important, e.g. the Dandy Walker continuum. (orig.)

  17. Oral azithromycin for treatment of posterior blepharitis.

    Science.gov (United States)

    Igami, Thais Zamudio; Holzchuh, Ricardo; Osaki, Tammy Hentona; Santo, Ruth Miyuki; Kara-Jose, Newton; Hida, Richard Y

    2011-10-01

    To evaluate the effects of oral azithromycin in patients with posterior blepharitis. Twenty-six eyes of 13 patients with posterior blepharitis diagnosed by a qualified ophthalmologist were enrolled in this study. Patients were instructed to use oral azithromycin 500 mg per day for 3 days in 3 cycles with 7-day intervals. Subjective clinical outcomes were graded and scored 1 day before and 30 days after the end of the treatment (53 days after initiating the treatment) based on severity scores of: (1) eyelid debris; (2) eyelid telangiectasia; (3) swelling of the eyelid margin; (4) redness of the eyelid margin; and (5) ocular mucus secretion. For the assessment of global efficacy, patients were asked by the investigator to rate the subjective symptoms (eyelid itching, ocular itching, eyelid hyperemia, ocular hyperemia, ocular mucus secretion, photophobia, foreign body sensation, and dry eye sensation) on a scale of 0 (no symptoms) to 5 (severe symptoms). Break-up time, Schirmer I test, corneal fluorescein staining score, and rose bengal staining score were also performed in all patients. All clinical outcomes scoring showed statistically significant improvement after oral azithromycin, except for eyelid swelling. Average subjective symptom grading improved statistically after treatment with oral azithromycin, except for eyelid hyperemia, photophobia, and foreign body sensation. Average tear film break-up time values showed statistically significant improvement after the treatment with oral azithromycin. No statistically significant improvement was observed on average values of Schirmer I test, corneal fluorescein staining score, and rose bengal staining score. The combination of multiple clinical parameters shown in this study supports the clinical efficacy of pulsed oral azithromycin therapy for the management of posterior blepharitis.

  18. MRI of the fetal posterior fossa

    International Nuclear Information System (INIS)

    Adamsbaum, Catherine; Andre, Christine; Merzoug, Valerie; Ferey, Solene; Moutard, Marie Laure; Quere, Marie Pierre; Lewin, Fanny; Fallet-Bianco, Catherine

    2005-01-01

    MRI is a useful tool to complement US for imaging of the fetal posterior fossa (PF). In France, the discovery of a PF malformation in the fetus frequently leads to termination of pregnancy (80% in a personal series). However, despite improved accuracy in the diagnosis of PF abnormalities, prognosis remains uncertain. The first objective of this review is to document the normal MRI landmarks of the developing fetal PF. Because of their thinness, the visibility of the cerebellar fissures is dramatically delayed on MRI compared to macroscopic data. An important landmark is identification of the primary fissure of the vermis, normally seen at around 25-26 weeks' gestation (WG) on the sagittal slice, separating the larger posterior lobe from the anterior lobe (volume ratio around 2:1). The prepyramidal and secondary fissures are usually only identifiable after 32 WG and the hemispheric fissures are difficult to see until the end of pregnancy. Considering the signal changes, high signal on T2-weighted (T2-W) sequences is seen from 25 WG in the posterior part of the brain stem (tegmentum and ascending sensory tracts) related to myelination. The low signal intensities seen within the cerebellum on T2-W images correspond to high cellularity of grey matter (deep nuclei), as there is no myelination within the white matter before 38 WG. The second objective is to highlight the signs highly predictive of a poor neurological prognosis. Lack of pontine curvature or vermian agenesis without a PF cyst (small volume of PF) is greatly associated with poor neurological status. The third objective is to propose a diagnostic strategy in difficult cases where prognosis is important, e.g. the Dandy Walker continuum. (orig.)

  19. SINDROME DE COLAPSO DE MORDIDA POSTERIOR

    Directory of Open Access Journals (Sweden)

    Paula Alejandra Baldión

    2012-12-01

    Full Text Available El Síndrome de Colapso de Mordida posterior es una patología oclusal que se presenta como consecuencia de problemas dentales, periodontales y oclusales, que exige la correcta evaluación de los signos y síntomas que lo caracterizan.  El objetivo del artículo es describir la manera como evoluciona la enfermedad, la evaluación multidisciplinaria para obtener un diagnóstico preciso y la secuencia de tratamiento integral, revisando los conceptos para un mejor entendimiento del tratamiento periodontal y restaurativo que requieren los pacientes con síndrome de colapso de mordida posterior; caracterizado por procesos patológicos como enfermedad periodontal, caries dental con subsecuente alteración de la integridad del arco dentario que genera perdida de soporte posterior conllevando a un trauma oclusal secundario y disminución de la dimensión vertical oclusal. El control del proceso inflamatorio y la estabilización periodontal son puntos de partida indispensables en el tratamiento integral del paciente. La migración patológica de los dientes y las alteraciones del plano oclusal pueden exigir la corrección ortodóntica de los arcos y en algunos casos el concurso de cirugía oral para la nivelación del plano oclusal. La secuencia organizada del tratamiento por fases permite la restauración predecible de los pacientes con este síndrome, tomando en cuenta las diferentes alternativas protésicas tanto removibles como fijas con o sin implantes de oseointegración, para el éxito integral a largo plazo.

  20. Comparison of two methods for anterior-posterior isocenter localization in pelvic radiotherapy using electronic portal imaging

    International Nuclear Information System (INIS)

    Greer, Peter B.; Mortensen, Trina M.; Jose, C.C.

    1998-01-01

    Purpose: The two setup methods commonly used to determine the anterior-posterior isocenter location in pelvic radiotherapy are to align lateral localization lasers with lateral skin tattoos on the patient, or to set the couch height so that the isocenter is at a fixed height (determined during simulation or treatment planning) above the couch top. This study was implemented to determine which technique gives more accurate patient treatment by comparison of the anterior-posterior setup variation measured with electronic portal imaging. Methods and Materials: Eleven supine prostate patients were treated with tattoo localization and 159 left-lateral portal images were taken during the treatments. The field displacements were then determined by template matching. These patients were compared to nine patients (205 images) set up to a fixed isocenter height. Similarly, eight prone rectal patients (136 right-lateral images) set up to tattoos were compared to six patients (108 images) set up to a fixed height. The patients were not immobilized and were all treated with three field techniques on a hard couch top. The overall mean treatment position deviation and the standard deviation of the displacements (total setup variation) were calculated for each patient group along with the systematic (simulator-to-treatment) and the random (treatment-to-treatment) setup variation. Results: The mean treatment position deviations were 3.3 mm anterior and 5.2 mm posterior with the tattoo method for the prostate and rectal patients, respectively. These mean position deviations were 0.4/0.1 mm anterior with the fixed height technique. The total setup variations were 4.6/5.2 mm (1 SD) with tattoo localization and 1.7/1.5 mm (1 SD) with the fixed height method. Similarly, random variation was 2.3/3.3 mm (1 SD) with the tattoo method compared to 1.3/1.2 mm (1 SD) with the fixed height method. Systematic variation was 3.7/4.5 mm (1 SD) compared to 1.2/1.1 mm (1 SD). Conclusion: The fixed

  1. Post-partum posterior reversible encephalopathy syndrome

    DEFF Research Database (Denmark)

    Aaen, Anne Albers; Jeppesen, Jørgen; Obaid, Hayder

    2015-01-01

    Posterior reversible encephalopathy syndrome (PRES) is a complex clinical condition with vasogenic subcortical oedema caused by hypertension. Oedema is often seen on magnetic resonance imaging. The wide clinical spectrum ranges from headaches to vision loss and even death. Early diagnosis...... and treatment is important for the reversibility of the condition. In this case report we emphasize the importance of blood pressure control in a post-partum woman, who had a rather complicated pregnancy. The symptoms of PRES were not recognized immediately because of failure to use and acknowledge a blood...

  2. Superior labrum anterior-to-posterior tear.

    Science.gov (United States)

    Sum, Jonathan C; Omid, Reza

    2012-12-01

    The patient was a 25-year-old male college student with a chief complaint of right shoulder pain. The patient was initially diagnosed with bicipital tendinitis by his physician and had been treated for 4 weeks by a physical therapist. However, his symptoms did not improve and he was unable to return to his preinjury activity levels, so he sought the services of another physical therapist for a second opinion. Due to concern for a labrum tear, the physical therapist referred the patient to an orthopaedic surgeon. Magnetic resonance arthrography revealed findings consistent with a superior labrum anterior-to-posterior tear.

  3. Post-partum posterior reversible encephalopathy syndrome

    DEFF Research Database (Denmark)

    Aaen, Anne Albers; Jeppesen, Jørgen; Obaid, Hayder

    2015-01-01

    and treatment is important for the reversibility of the condition. In this case report we emphasize the importance of blood pressure control in a post-partum woman, who had a rather complicated pregnancy. The symptoms of PRES were not recognized immediately because of failure to use and acknowledge a blood......Posterior reversible encephalopathy syndrome (PRES) is a complex clinical condition with vasogenic subcortical oedema caused by hypertension. Oedema is often seen on magnetic resonance imaging. The wide clinical spectrum ranges from headaches to vision loss and even death. Early diagnosis...

  4. [Post-partum posterior reversible encephalopathy syndrome].

    Science.gov (United States)

    Aaen, Anne Albers; Jeppesen, Jørgen; Obaid, Hayder; Bülow, Hans Henrik

    2015-11-23

    Posterior reversible encephalopathy syndrome (PRES) is a complex clinical condition with vasogenic subcortical oedema caused by hypertension. Oedema is often seen on magnetic resonance imaging. The wide clinical spectrum ranges from headaches to vision loss and even death. Early diagnosis and treatment is important for the reversibility of the condition. In this case report we emphasize the importance of blood pressure control in a post-partum woman, who had a rather complicated pregnancy. The symptoms of PRES were not recognized immediately because of failure to use and acknowledge a blood pressure test.

  5. Posterior breast cancer: Mammographic and ultrasonographic features

    Directory of Open Access Journals (Sweden)

    Janković Ana

    2013-01-01

    Full Text Available Background/Aim. Posterior breast cancers are located in the prepectoral region of the breast. Owing to this distinctive anatomical localization, physical examination and mammographic or ultrasonographic evaluation can be difficult. The purpose of the study was to assess possibilities of diagnostic mammography and breast ultrasonography in detection and differentiation of posterior breast cancers. Methods. The study included 40 women with palpable, histopathological confirmed posterior breast cancer. Mammographic and ultrasonographic features were defined according to Breast Imaging Reporting and Data System (BI-RADS lexicon. Results. Based on standard two-view mammography 87.5%, of the cases were classified as BI-RADS 4 and 5 categories, while after additional mammographic views all the cases were defined as BIRADS 4 and 5 categories. Among 96 mammographic descriptors, the most frequent were: spiculated mass (24.0%, architectural distortion (16.7%, clustered microcalcifications (12.6% and focal asymmetric density (12.6%. The differentiation of the spiculated mass was significantly associated with the possibility to visualize the lesion at two-view mammography (p = 0.009, without the association with lesion diameter (p = 0.083 or histopathological type (p = 0.055. Mammographic signs of invasive lobular carcinoma were significantly different from other histopathological types (architectural distortion, p = 0.003; focal asymmetric density, p = 0.019; association of four or five subtle signs of malignancy, p = 0.006. All cancers were detectable by ultrasonography. Mass lesions were found in 82.0% of the cases. Among 153 ultrasonographic descriptors, the most frequent were: irregular mass (15.7%, lobulated mass (7.2%, abnormal color Doppler signals (20.3%, posterior acoustic attenuation (18.3%. Ultrasonographic BI-RADS 4 and 5 categories were defined in 72.5% of the cases, without a significant difference among various histopathological types (p = 0

  6. Distrofia corneana policromática posterior Polychromatic posterior corneal dystrophy

    OpenAIRE

    Patrick Frensel de Moraes Tzelikis; Ulisses Roberto dos Santos; Marco Antônio Guarino Tanure; Fernando Cançado Trindade

    2007-01-01

    Os autores descrevem quatro raros casos de distrofia corneana policromática posterior, ainda não descrito na literatura nacional. Observam-se opacidades puntiformes, policromáticas, de tamanho uniforme, localização estromal profunda, distribuídas de limbo a limbo e que não interferem na acuidade visual. É apresentada uma revisão dos casos de distrofia pré-Descemet existentes na literatura.The authors describe four rare cases of polychromatic posterior corneal dystrophy, not describe in nation...

  7. Distrofia corneana amorfa posterior: relato de caso Posterior amorphous corneal dystrophy: case report

    Directory of Open Access Journals (Sweden)

    Lauro Augusto de Oliveira

    2006-12-01

    Full Text Available O objetivo deste trabalho é alertar o oftalmologista da possibilidade de se deparar com casos raros de distrofias corneanas. Neste caso correlacionamos os achados clínicos da distrofia amorfa posterior com refração, topografia e biomicroscopia ultra-sônica.The purpose of this paper is to warn the ophthalmologist about the possibility of facing rare cases of corneal dystrophies. Clinical findings of a case of posterior amorphous dystrophy were correlated with refraction, topography, and ultrasound biomicroscopy.

  8. The role of the posterior cruciate ligament in total knee replacement

    Science.gov (United States)

    Ritter, M. A.; Davis, K. E.; Meding, J. B.; Farris, A.

    2012-01-01

    Objectives The purpose of this study was to examine the effect of posterior cruciate ligament (PCL) retention, PCL recession, and PCL excision during cruciate-retaining total knee replacement. Methods A total of 3018 anatomic graduated component total knee replacements were examined; 1846 of these retained the PCL, 455 PCLs were partially recessed, and in 717 the PCL was completely excised from the back of the tibia. Results Clinical scores between PCL groups favored excision for flexion (p knees, 98.2% for recessed knees, and 96.4% for excised knees (p = 0.0934, Wilcoxon; p = 0.0202, log-rank). Conclusions Despite some trade off in clinical performance, if the PCL is detached at the time of operation, conversion to a posterior-stabilised prosthesis may not be necessarily required as long as stability in the anteroposterior and coronal planes is achieved. PMID:23610673

  9. Reactive histiocytosis of the orbit and posterior segment in a dog.

    Science.gov (United States)

    Pumphrey, Stephanie A; Pizzirani, Stefano; Pirie, Christopher G; Sato, Amy F; Buckley, Faith I

    2013-05-01

    We present a case of reactive histiocytic disease involving the orbit, optic nerve, retina, and choroid in a Border Collie dog initially presenting for vision loss. Long-term partial return of vision has been achieved with systemic immunosuppression. Anterior segment and ocular surface manifestations of reactive histiocytic disease in dogs are relatively common. Posterior segment and orbital involvement, however, are minimally documented in the existing literature. To the authors' knowledge, this is the first report of disease confined to the orbit and posterior segment as well as the first report of vision loss as a presenting complaint for reactive histiocytic disease. Clinical, magnetic resonance imaging, cytologic, and histopathologic findings are reviewed. © 2012 American College of Veterinary Ophthalmologists.

  10. The benefit of differential moment concept in managing posterior anchorage and avoiding bite deepening

    Directory of Open Access Journals (Sweden)

    Harryanto Wijaya

    2012-09-01

    Full Text Available Background: Anchorage is one of the major concerns in orthodontic space closure. Various methods have been proposed to enhance posterior anchorage in space closure such as headgear, Nance holding appliance, and micro implant as temporary anchorage devices. However, several issues such as patient's compliance, appliance effectiveness, and cost of the device become many clinicians concern. The differential moment concept in segmented arch is a technique that requires no patient compliance but can effectively manage posterior anchorage and avoid bite deepening by careful application of forces and moments. Purpose: The purpose of this case report is to show the use of differential moment concept in segmented arch technique to manage posterior anchorage and to avoid bite deepening. Case: A 21 years old female patient with protrusive teeth as her chief complaint was treated using fixed orthodontic appliance. Case management: The treatment included four first bicuspid extraction and space closure utilizing differential moment concept in segmented arch. Conclusion: It can be concluded that application of differential moment concept in segmented arch technique is a non invasive, compliance independent, effective, and cost efficient method to manage posterior anchorage and to avoid bite deepening.latar belakang: Penjangkaran merupakan salah satu aspek yang sering kali menjadi masalah dalam penutupan ruang pada perawatan ortodonti. Berbagai metode disarankan untuk memperkuat penjangkaran posterior dalam penutupan ruang seperti headgear, piranti penahan Nance, dan implan mikro sebagai alat penjangkar sementara. Namun demikian, beberapa hal seperti kerjasama pasien, efektivitas piranti, dan biaya dari alat-alat tersebut sering menjadi perhatian/pertimbangan bagi klinisi. Konsep momen diferensial pada segmented arch adalah suatu cara yang efektif untuk memperkuat penjangkaran dan menghindari pendalaman gigitan tanpa memerlukan kerjasama pasien. tujuan

  11. Fixed Target Collisions at STAR

    Energy Technology Data Exchange (ETDEWEB)

    Meehan, Kathryn C.

    2016-12-15

    The RHIC Beam Energy Scan (BES) program was proposed to look for the turn-off of signatures of the quark gluon plasma (QGP), search for a possible QCD critical point, and study the nature of the phase transition between hadronic and partonic matter. Previous results have been used to claim that the onset of deconfinement occurs at a center-of-mass energy of 7 GeV. Data from lower energies are needed to test if this onset occurs. The goal of the STAR Fixed-Target Program is to extend the collision energy range in BES II to energies that are likely below the onset of deconfinement. Currently, STAR has inserted a gold target into the beam pipe and conducted test runs at center-of-mass energies of 3.9 and 4.5 GeV. Tests have been done with both Au and Al beams. First physics results from a Coulomb potential analysis of Au + Au fixed-target collisions are presented and are found to be consistent with results from previous experiments. Furthermore, the Coulomb potential, which is sensitive to the Z of the projectile and degree of baryonic stopping, will be compared to published results from the AGS.

  12. Utilization of nitrogen fixing trees

    Energy Technology Data Exchange (ETDEWEB)

    Brewbaker, J.L.; Beldt, R. van den; MacDicken, K.; Budowski, G.; Kass, D.C.L.; Russo, R.O.; Escalante, G.; Herrera, R.; Aranguren, J.; Arkcoll, D.B.; Doebereinger, J. (cord.)

    1983-01-01

    Six papers from the symposium are noted. Brewbaker, J.L., Beldt, R. van den, MacDicken, K. Fuelwood uses and properties of nitrogen-fixing trees, pp 193-204, (Refs. 15). Includes a list of 35 nitrogen-fixing trees of high fuelwood value. Budowski, G.; Kass, D.C.L.; Russo, R.O. Leguminous trees for shade, pp 205-222, (Refs. 68). Escalante, G., Herrera, R., Aranguren, J.; Nitrogen fixation in shade trees (Erythrina poeppigiana) in cocoa plantations in northern Venezuela, pp 223-230, (Refs. 13). Arkcoll, D.B.; Some leguminous trees providing useful fruits in the North of Brazil, pp 235-239, (Refs. 13). This paper deals with Parkia platycephala, Pentaclethra macroloba, Swartzia sp., Cassia leiandra, Hymenaea courbaril, dipteryz odorata, Inga edulis, I. macrophylla, and I. cinnamonea. Baggio, A.J.; Possibilities of the use of Gliricidia sepium in agroforestry systems in Brazil, pp 241-243; (Refs. 15). Seiffert, N.F.; Biological nitrogen and protein production of Leucaena cultivars grown to supplement the nutrition of ruminants, pp 245-249, (Refs. 14). Leucaena leucocephala cv. Peru, L. campina grande (L. leucocephala), and L. cunningham (L. leucocephalae) were promising for use as browse by beef cattle in central Brazil.

  13. Fixed-Target Electron Accelerators

    International Nuclear Information System (INIS)

    Brooks, William K.

    2001-01-01

    A tremendous amount of scientific insight has been garnered over the past half-century by using particle accelerators to study physical systems of sub-atomic dimensions. These giant instruments begin with particles at rest, then greatly increase their energy of motion, forming a narrow trajectory or beam of particles. In fixed-target accelerators, the particle beam impacts upon a stationary sample or target which contains or produces the sub-atomic system being studied. This is in distinction to colliders, where two beams are produced and are steered into each other so that their constituent particles can collide. The acceleration process always relies on the particle being accelerated having an electric charge; however, both the details of producing the beam and the classes of scientific investigations possible vary widely with the specific type of particle being accelerated. This article discusses fixed-target accelerators which produce beams of electrons, the lightest charged particle. As detailed in the report, the beam energy has a close connection with the size of the physical system studied. Here a useful unit of energy is a GeV, i.e., a giga electron-volt. (ne GeV, the energy an electron would have if accelerated through a billion volts, is equal to 1.6 x 10 -10 joules.) To study systems on a distance scale much smaller than an atomic nucleus requires beam energies ranging from a few GeV up to hundreds of GeV and more

  14. Improved Landau gauge fixing and discretisation errors

    International Nuclear Information System (INIS)

    Bonnet, F.D.R.; Bowman, P.O.; Leinweber, D.B.; Richards, D.G.; Williams, A.G.

    2000-01-01

    Lattice discretisation errors in the Landau gauge condition are examined. An improved gauge fixing algorithm in which O(a 2 ) errors are removed is presented. O(a 2 ) improvement of the gauge fixing condition displays the secondary benefit of reducing the size of higher-order errors. These results emphasise the importance of implementing an improved gauge fixing condition

  15. Partial differential equations

    CERN Document Server

    Evans, Lawrence C

    2010-01-01

    This text gives a comprehensive survey of modern techniques in the theoretical study of partial differential equations (PDEs) with particular emphasis on nonlinear equations. The exposition is divided into three parts: representation formulas for solutions; theory for linear partial differential equations; and theory for nonlinear partial differential equations. Included are complete treatments of the method of characteristics; energy methods within Sobolev spaces; regularity for second-order elliptic, parabolic, and hyperbolic equations; maximum principles; the multidimensional calculus of variations; viscosity solutions of Hamilton-Jacobi equations; shock waves and entropy criteria for conservation laws; and, much more.The author summarizes the relevant mathematics required to understand current research in PDEs, especially nonlinear PDEs. While he has reworked and simplified much of the classical theory (particularly the method of characteristics), he primarily emphasizes the modern interplay between funct...

  16. Periodontal ligament influence on the stress distribution in a removable partial denture supported by implant: a finite element analysis

    Directory of Open Access Journals (Sweden)

    Carlos Marcelo Archangelo

    2012-06-01

    Full Text Available OBJECTIVES: The non-homogenous aspect of periodontal ligament (PDL has been examined using finite element analysis (FEA to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD is partially supported by an osseointegrated implant. MATERIAL AND METHODS: Six finite element (FE models of a partially edentulous mandible were created to represent two types of PDL (non-homogenous and homogenous and two types of RPD (conventional RPD, supported by tooth and fibromucosa; and modified RPD, supported by tooth and implant [10.00x3.75 mm]. Two additional Fe models without RPD were used as control models. The non-homogenous PDL was modeled using beam elements to simulate the crest, horizontal, oblique and apical fibers. The load (50 N was applied in each cusp simultaneously. Regarding boundary conditions the border of alveolar ridge was fixed along the x axis. The FE software (Ansys 10.0 was used to compute the stress fields, and the von Mises stress criterion (svM was applied to analyze the results. RESULTS: The peak of svM in non-homogenous PDL was higher than that for the homogenous condition. The benefits of implants were enhanced for the non-homogenous PDL condition, with drastic svM reduction on the posterior half of the alveolar ridge. The implant did not reduce the stress on the support tooth for both PDL conditions. Conclusion: The PDL modeled in the non-homogeneous form increased the benefits of the osseointegrated implant in comparison with the homogeneous condition. Using the non-homogenous PDL, the presence of osseointegrated implant did not reduce the stress on the supporting tooth.

  17. Experiences in Performing Posterior Calvarial Distraction.

    Science.gov (United States)

    McMillan, Kevin; Lloyd, Mark; Evans, Martin; White, Nicholas; Nishikawa, Hiroshi; Rodrigues, Desiderio; Sharp, Melanie; Noons, Pete; Solanki, Guirish; Dover, Stephen

    2017-05-01

    The use of posterior calvarial distraction (PCD) for the management of craniosynostosis is well recognized. The advantages of using this technique include increased cranial volume, decreased intracranial pressure, relief of posterior fossa crowding, improved cerebrospinal fluid (CSF) circulation at the cranio-cervical junction with cessation, and possible resolution of syrinx.The authors retrospectively review their first 50 patients who have undergone PCD under the senior author's care in our unit.The demographics, diagnoses, intraoperative approach with techniques in distractor placement and outcomes of each patient were obtained through an electronic craniofacial database and written patient records. Analysis of complication rates (bleeding, distraction problems, CSF leaks, and infection) was included.A total of 31 boys and 19 girls underwent the procedure between October 2006 and September 2015 with a median age was 17.7 months (range 4 months to 19 years). Of those 50 children, 34 of the cohort were proven to be syndromic by genetic testing.The median length of inpatient stay was 9.4 days (range 3-43 days). Average distraction distance was 24 mm.Complications including CSF leaks, bleeding, distractor problems, and severe complications (recorded in 3 patients) are discussed. Our overall complication rate was 50%.Favorable outcomes included resolution of Chiari, syrinx, and raised intracranial pressure in the majority of patients where distraction was successful.The authors recommend that PCD should be considered the primary treatment for increasing calvarial volume. The authors discuss our experiences and technical innovations over the past decade.

  18. Acute Spontaneous Posterior Fossa Subdural Hematoma

    Directory of Open Access Journals (Sweden)

    Osama Shukir Muhammed Amin

    2014-02-01

    Full Text Available Acute posterior fossa subdural hematomas are rare and most of them are trauma-related. Non-traumatic ones have been reported in patients who had idiopathic thrombocytopenic purpura or those who had been receiving anticoagulant therapy. We report on the case of 57-year-old Iranian man who developed sudden severe occipital headache, drowsiness, repeated vomiting, and instability of stance and gait. He was neither hypertensive nor diabetic. No history of head trauma was obtained and he denied illicit drug or alcohol ingestion. A preliminary diagnosis of acute intra-cerebellar hemorrhage was made. His CT brain scan revealed an acute right-sided, extra-axial, crescent-shaped hyperdense area at the posterior fossa. His routine blood tests, platelets count, bleeding time, and coagulation profile were unremarkable. The patient had spontaneous acute infratentorial subdural hematoma. He was treated conservatively and discharged home well after 5 days. Since then, we could not follow-up him, clinically and radiologically because he went back to Iran. Our patient’s presentation, clinical course, and imaging study have called for conservative management, as the overall presentation was relatively benign. Unless the diagnosis is entertained and the CT brain scan is well-interpreted, the diagnosis may easily escape detection.

  19. MRI diagnosis of posterior fossa tumors

    International Nuclear Information System (INIS)

    Yamashita, Yasuyuki; Takahashi, Mutsumasa; Sakamoto, Yuuji; Kojima, Ryutarou; Bussaka, Hiromasa; Korogi, Yukunori

    1988-01-01

    Magnetic resonance images (MRI) of 58 patients with posterior fossa tumors were compared with computed tomography (CT). Spin echo (SE) technique and inversion recovery (IR) technique were obtained using 0.22 tesla resistive magnetic resonance unit. MRI was superior to CT in detecting the lesions and showing internal archtecture, hemorrhage, edema of the tumor and displacement of the normal brain. CT was superior to MRI in demonstrating calcification. MRI and CT were comparable in detecting erosions of the skull base, while MRI was superior to CT in showing erosions of the clivus. Most tumors showed hypointensity on T1 weighted images and hyperintensity on T2 weighted images. Meningioma showed equal or almost equal intensity to cerebral gray matter on both SE images. The boundary of intra-axial tumors was unclear in many cases without contrast enhancement using Gd-DTPA, while most extra-axial tumors showed clear margin surrounded by a thin band (rim). In 81.8 % of acoustic neurinomas, signal void rims were demonstrated on both SE images, and they were considered to be vessels around the tumor. The rims of meningioma, on the other hand, were hypointense on T1 weighted images and hyperintense on T2 weighted images. They were considered to be cerebrospinal fluid or capsule around the tumor. It has been concluded that MRI is the most important technique for diagnosis of posterior fossa tumors. (author)

  20. [Diagnosis and management of posterior urethra disruptions].

    Science.gov (United States)

    Bensalah, K; Manunta, A; Guillé, F; Patard, J J

    2006-10-01

    Rupture of posterior urethra is usually seen in major traumas with associated pelvic fractures. Clinical presentation classically associates blood at the uretral meatus and urinary retention. Urinary diversion should be achieved by suprapubic puncture and major associated traumatic injuries (abdominal, orthopaedic, and neurological lesions) must be treated prior to urological management. Retrograde uretrocystography is performed a few days later in order to localize and classify the urethral lesion. Treatment of posterior urethral ruptures has evolved over the years. Immediate open repair is no longer recommended. The supra-pubic catheter can be left in place until resorption of the pelvic hematoma. Obliteration occurs in 100% of the cases and is treated by open surgery at 3 months. More and more patients are treated by early endoscopic realignment which has diminished by half the incidence of urethral strictures. Impotence and incontinence secondary to trauma or surgery occur in 20% and 10% of the patients respectively. Long term follow-up should be achieved in every patient.

  1. SINDROME DE COLAPSO DE MORDIDA POSTERIOR

    Directory of Open Access Journals (Sweden)

    Paula Alejandra Baldión

    2012-07-01

    El objetivo del artículo es describir la manera como evoluciona la enfermedad, la evaluación multidisciplinaria para obtener un diagnóstico preciso y la secuencia de tratamiento integral, revisando los conceptos para un mejor entendimiento del tratamiento periodontal y restaurativo que requieren los pacientes con síndrome de colapso de mordida posterior; caracterizado por procesos patológicos como enfermedad periodontal, caries dental con subsecuente alteración de la integridad del arco dentario que genera perdida de soporte posterior conllevando a un trauma oclusal secundario y disminución de la dimensión vertical oclusal. El control del proceso inflamatorio y la estabilización periodontal son puntos de partida indispensables en el tratamiento integral del paciente. La migración patológica de los dientes y las alteraciones del plano oclusal pueden exigir la corrección ortodóntica de los arcos y en algunos casos el concurso de cirugía oral para la nivelación del plano oclusal. La secuencia organizada del tratamiento por fases permite la restauración predecible de los pacientes con este síndrome, tomando en cuenta las diferentes alternativas protésicas tanto removibles como fijas con o sin implantes de oseointegración, para el éxito integral a largo plazo.

  2. Bayesian posterior distributions without Markov chains.

    Science.gov (United States)

    Cole, Stephen R; Chu, Haitao; Greenland, Sander; Hamra, Ghassan; Richardson, David B

    2012-03-01

    Bayesian posterior parameter distributions are often simulated using Markov chain Monte Carlo (MCMC) methods. However, MCMC methods are not always necessary and do not help the uninitiated understand Bayesian inference. As a bridge to understanding Bayesian inference, the authors illustrate a transparent rejection sampling method. In example 1, they illustrate rejection sampling using 36 cases and 198 controls from a case-control study (1976-1983) assessing the relation between residential exposure to magnetic fields and the development of childhood cancer. Results from rejection sampling (odds ratio (OR) = 1.69, 95% posterior interval (PI): 0.57, 5.00) were similar to MCMC results (OR = 1.69, 95% PI: 0.58, 4.95) and approximations from data-augmentation priors (OR = 1.74, 95% PI: 0.60, 5.06). In example 2, the authors apply rejection sampling to a cohort study of 315 human immunodeficiency virus seroconverters (1984-1998) to assess the relation between viral load after infection and 5-year incidence of acquired immunodeficiency syndrome, adjusting for (continuous) age at seroconversion and race. In this more complex example, rejection sampling required a notably longer run time than MCMC sampling but remained feasible and again yielded similar results. The transparency of the proposed approach comes at a price of being less broadly applicable than MCMC.

  3. Study of hemostasis procedures for posterior epistaxis.

    Science.gov (United States)

    Iimura, Jiro; Hatano, Atsushi; Ando, Yuji; Arai, Chiaki; Arai, Satoshi; Shigeta, Yasushi; Kojima, Hiromi; Otori, Nobuyoshi; Wada, Kota

    2016-06-01

    Hemostasis is difficult in patients with bleeding emanating from the deep regions in the nasal cavity; however, there is no standard treatment method. We studied hemostasis procedures in patients who visited our outpatient department and presented with idiopathic epistaxis extending from the posterior nasal cavity to Kiesselbach's area. The subjects were patients with epistaxis who visited our hospital between June 2008 and May 2010. We asked specific questions at the time of the hospital visit and examined patients using a nasal speculum, a flexible endoscope, and a rigid endoscope (0 or 70 degree) to identify bleeding sites. Hemostasis using electrocoagulation was selected as the first-line therapy for patients in whom a bleeding point had been identified, whereas hemostasis using a gauze tampon was performed in patients in whom the bleeding point was unknown. The subjects were analyzed by multivariate logistic regression analysis. The bleeding point was unknown in most cases of recurrent posterior epistaxis. Electrocoagulation was the best hemostasis procedure. Identifying the bleeding points as much as possible and performing electrocoagulation at these sites was the preferred procedures. We propose the treatment procedure for refractory epistaxis. When it is difficult to identify a bleeding point in a patient with refractory epistaxis due to a deviated nasal septum, a bleeding point should be identified after septoplasty; for bleeding from the sphenopalatine artery region, electrocoagulation or endoscopic cauterization of the sphenopalatine artery should be performed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Optimization of partial search

    International Nuclear Information System (INIS)

    Korepin, Vladimir E

    2005-01-01

    A quantum Grover search algorithm can find a target item in a database faster than any classical algorithm. One can trade accuracy for speed and find a part of the database (a block) containing the target item even faster; this is partial search. A partial search algorithm was recently suggested by Grover and Radhakrishnan. Here we optimize it. Efficiency of the search algorithm is measured by the number of queries to the oracle. The author suggests a new version of the Grover-Radhakrishnan algorithm which uses a minimal number of such queries. The algorithm can run on the same hardware that is used for the usual Grover algorithm. (letter to the editor)

  5. Objective assessment of mastication predominance in healthy dentate subjects and patients with unilateral posterior missing teeth.

    Science.gov (United States)

    Yamasaki, Y; Kuwatsuru, R; Tsukiyama, Y; Oki, K; Koyano, K

    2016-08-01

    We aimed to investigate mastication predominance in healthy dentate individuals and patients with unilateral posterior missing teeth using objective and subjective methods. The sample comprised 50 healthy dentate individuals (healthy dentate group) and 30 patients with unilateral posterior missing teeth (partially edentulous group). Subjects were asked to freely chew three kinds of test foods (peanuts, beef jerky and chewing gum). Electromyographic activity of the bilateral masseter muscles was recorded. The chewing side (right side or left side) was judged by the level of root mean square electromyographic amplitude. Mastication predominance was then objectively assessed using the mastication predominant score and the mastication predominant index. Self-awareness of mastication predominance was evaluated using a modified visual analogue scale. Mastication predominance scores of the healthy dentate and partially edentulous groups for each test food were analysed. There was a significant difference in the distribution of the mastication predominant index between the two groups (P mastication predominant score was weakly correlated with self-awareness of mastication predominance in the healthy dentate group, whereas strong correlation was observed in the partially edentulous group (P mastication predominance and were more aware of mastication predominance than healthy dentate individuals. Our findings suggest that an objective evaluation of mastication predominance is more precise than a subjective method. © 2016 John Wiley & Sons Ltd.

  6. The effects of superimposed tilt and lower body negative pressure on anterior and posterior cerebral circulations.

    Science.gov (United States)

    Tymko, Michael M; Rickards, Caroline A; Skow, Rachel J; Ingram-Cotton, Nathan C; Howatt, Michael K; Day, Trevor A

    2016-09-01

    Steady-state tilt has no effect on cerebrovascular reactivity to increases in the partial pressure of end-tidal carbon dioxide (PETCO2). However, the anterior and posterior cerebral circulations may respond differently to a variety of stimuli that alter central blood volume, including lower body negative pressure (LBNP). Little is known about the superimposed effects of head-up tilt (HUT; decreased central blood volume and intracranial pressure) and head-down tilt (HDT; increased central blood volume and intracranial pressure), and LBNP on cerebral blood flow (CBF) responses. We hypothesized that (a) cerebral blood velocity (CBV; an index of CBF) responses during LBNP would not change with HUT and HDT, and (b) CBV in the anterior cerebral circulation would decrease to a greater extent compared to posterior CBV during LBNP when controlling PETCO2 In 13 male participants, we measured CBV in the anterior (middle cerebral artery, MCAv) and posterior (posterior cerebral artery, PCAv) cerebral circulations using transcranial Doppler ultrasound during LBNP stress (-50 mmHg) in three body positions (45°HUT, supine, 45°HDT). PETCO2 was measured continuously and maintained at constant levels during LBNP through coached breathing. Our main findings were that (a) steady-state tilt had no effect on CBV responses during LBNP in both the MCA (P = 0.077) and PCA (P = 0.583), and (b) despite controlling for PETCO2, both the MCAv and PCAv decreased by the same magnitude during LBNP in HUT (P = 0.348), supine (P = 0.694), and HDT (P = 0.407). Here, we demonstrate that there are no differences in anterior and posterior circulations in response to LBNP in different body positions. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  7. Adhesives for fixed orthodontic brackets.

    Science.gov (United States)

    Mandall, Nicky A; Hickman, Joy; Macfarlane, Tatiana V; Mattick, Rye Cr; Millett, Declan T; Worthington, Helen V

    2018-04-09

    Bonding of orthodontic brackets to teeth is important to enable effective and efficient treatment with fixed appliances. The problem is bracket failure during treatment which increases operator chairside time and lengthens treatment time. A prolonged treatment is likely to increase the oral health risks of orthodontic treatment with fixed appliances one of which is irreversible enamel decalcification. This is an update of the Cochrane Review first published in 2003. A new full search was conducted on 26 September 2017 but no new studies were identified. We have only updated the search methods section in this new version. The conclusions of this Cochrane Review remain the same. To evaluate the effects of different orthodontic adhesives for bonding. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 26 September 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 8) in the Cochrane Library (searched 26 September 2017), MEDLINE Ovid (1946 to 26 September 2017), and Embase Ovid (1980 to 26 September 2017). The US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Trials were selected if they met the following criteria: randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing two different adhesive groups. Participants were patients with fixed orthodontic appliances. The interventions were adhesives that bonded stainless steel brackets to all teeth except the molars. The primary outcome was debond or bracket failure. Data were recorded on decalcification as a secondary outcome, if present. Information regarding methods, participants, interventions, outcome measures and results were extracted in

  8. Posterior fossa reconstruction using titanium plate for the treatment of cerebellar ptosis after decompression for Chiari malformation.

    Science.gov (United States)

    Udani, Vikram; Holly, Langston T; Chow, Daniel; Batzdorf, Ulrich

    2014-01-01

    We describe our use of a perforated titanium plate to perform a partial posterior fossa cranioplasty in the treatment of cerebellar ptosis and dural ectasia after posterior fossa decompression (PFD). Twelve patients who had undergone PFD underwent posterior fossa reconstruction using a titanium plate. Symptoms were related to either descent of the cerebellum into the decompression or to dural ectasia into the craniectomy defect. Twelve patients who had undergone large suboccipital craniectomies and who presented with persistent headaches and some with neurological symptoms related to syringomyelia, underwent reoperation with placement of a small titanium plate. Ten of 12 patients showed symptomatic improvement after reoperation. Placement of a titanium plate appears to be an effective method of treatment of cerebellar ptosis and dural ectasia after PFD for Chiari malformation. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Area densitometry using rotating Scheimpflug photography for posterior capsule opacification and surface light scattering analyses.

    Science.gov (United States)

    Minami, Keiichiro; Honbo, Masato; Mori, Yosai; Kataoka, Yasushi; Miyata, Kazunori

    2015-11-01

    To compare area densitometry analysis using rotating Scheimpflug photography in quantifications of posterior capsule opacification (PCO) and surface light scattering with previous anterior-segment analyzer measurement. Miyata Eye Hospital, Miyazaki, Japan. Prospective observational case series. Scheimpflug images of eyes with foldable intraocular lenses (IOLs) were obtained using rotating and fixed Scheimpflug photography. Area densitometry on the posterior and anterior surfaces was conducted for PCO and surface light scattering analyses, respectively, with an identical area size. Correlation between two measurements was analyzed using linear regression. The study included 105 eyes of 74 patients who received IOLs 1 to 18 years (mean, 4.9 ± 4.5 years) postoperatively. In the PCO analysis on the posterior IOL surface, there was a significant correlation between the two measurements (P photography exhibited saturation due to intensive scatterings. Area densitometry combined with a rotating Scheimpflug photography was exchangeable to previously established densitometry measurement, and allowed successive evaluation in longer-term observations. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. A very rare case with neglected hip dislocation coexisted with posterior acetabular lip fracture

    Directory of Open Access Journals (Sweden)

    Samet Karabulut

    2011-06-01

    Full Text Available Neglected hip dislocation is a rare situation among children. The coexistence of acetabulum fracture is less common. The result of treatment depends on the time of diagnosis. Early treatment is mandatory in such cases. Seven years old female brought to our outpatient clinic with the complaints of right hip pain and walking difficulty. Her parents said that she had fallen from a horse one month ago. X-ray and CT showed a posterior dislocation of her right hip and a fracture on her right posterior acetabular lip. We performed an open reduction via posterior approach. Because the hip was unstable we fixed the femoral head to the acetabulum by a Kirshner wire. Pelvipedal cast was applied after the operation for 6 weeks. After 6 months avascular necrosis (AVN developed on her right femoral head, the range of motion (ROM of the hip was restricted and she had minimal pain on her right hip. J Clin Exp Invest 2011;2(2:228-31

  11. Video-assisted thoracic surgery for superior posterior mediastinal neurogenic tumour in the supine position

    Directory of Open Access Journals (Sweden)

    Darlong Laleng

    2009-01-01

    Full Text Available Video-assisted thoracic surgery (VATS for a superior posterior mediastinal lesion is routinely done in the lateral decubitus position similar to a standard thoracotomy using a double-lumen endotracheal tube for one-lung ventilation. This is an area above the level of the pericardium, with the superior thoracic opening as its superior limit and its inferior limit at the plane from the sternal angle to the level of intervertebral disc of thoracic 4 to 5 vertebra lying behind the great vessels. The lateral decubitus position has disadvantages of the double-lumen endotracheal tube getting malpositioned during repositioning from supine position to the lateral decubitus position, shoulder injuries due to the prolonged abnormal fixed posture and rarer injuries of the lower limb. There is no literature related to VATS in the supine position for treating lesions in the posterior mediastinum because the lung tissue falls in the dependent posterior mediastinum and obscures the field of surgery; however, VATS in the supine position is routinely done for lesions in the anterior mediastinum and single-stage bilateral spontaneous pneumothorax. Thus, in the selected cases, ′VATS in supine position′ allows an invasive procedure to be completed in the most stable anatomical posture.

  12. Retention period after treatment of posterior crossbite with maxillary expansion: a systematic review

    Directory of Open Access Journals (Sweden)

    Julia Garcia Costa

    Full Text Available ABSTRACT OBJECTIVE: The aim of this systematic review was to evaluate the duration of the retention period in growing patients undergoing maxillary expansion and its relation with posterior crossbite stability. METHODS: Search strategies were executed for electronic databases Cochrane Library, Web of Science, PubMed and Scopus, which were completed on January 15, 2016. The inclusion criteria included randomized, prospective or retrospective controlled trials in growing subjects with posterior crossbite; treated with maxillary expanders; retention phase after expansion; post-retention phase of at least 6 months. The exclusion criteria were anterior crossbite, craniofacial anomalies, surgery or another orthodontic intervention; case reports; author’s opinions articles, thesis, literature reviews and systematic reviews. The risk of bias of selected articles was assessed with Cochrane risk of bias tool for RCTs and Downs and Black checklist for non-RCTs. RESULTS: A total of 156 titles/abstracts was retrieved, 44 full-texts were examined, and 6 articles were selected and assessed for their methodological quality. The retention period after maxillary expansion ranged between 4 weeks and 16 months. Fixed (acrylic plate, Haas, Hyrax and quad-helix or removable (Hawley and Hawley expander appliances were used for retention. CONCLUSIONS: Six months of retention with either fixed or removable appliances seem to be enough to avoid relapse or to guarantee minimal changes in a short-term follow-up.

  13. Posterior Urethroplasty Complexity and Prognosis Can be Described by a Novel Method: Posterior Urethral Stenosis Score.

    Science.gov (United States)

    Wang, Lin; Lv, Xiangguo; Jin, Chongrui; Guo, Hailin; Shu, Huiquan; Fu, Qiang; Sa, Yinglong

    2018-02-01

    To develop a standardized PU-score (posterior urethral stenosis score), with the goal of using this scoring system as a preliminary predictor of surgical complexity and prognosis of posterior urethral stenosis. We retrospectively reviewed records of all patients who underwent posterior urethral surgery at our institution from 2013 to 2015. The PU-score is based on 5 components, namely etiology (1 or 2 points), location (1-3 points), length (1-3 points), urethral fistula (1 or 2 points), and posterior urethral false passage (1 point). We calculated the score of all patients and analyzed its association with surgical complexity, stenosis recurrence, intraoperative blood loss, erectile dysfunction, and urinary incontinence. There were 144 patients who underwent low complexity urethral surgery (direct vision internal urethrotomy, anastomosis with or without crural separation) with a mean score of 5.1 points, whereas 143 underwent high complexity urethroplasty (anastomosis with inferior pubectomy or urethrorectal fistula repair, perineal or scrotum skin flap urethroplasty, bladder flap urethroplasty) with a mean score of 6.9 points. The increase of PU-score was predictive of higher surgical complexity (P = .000), higher recurrence (P = .002), more intraoperative blood loss (P = .000), and decrease of preoperative (P = .037) or postoperative erectile function (P = .047). However, no association was observed between PU-score and urinary incontinence (P = .213). The PU-score is a novel and meaningful scoring system that describes the essential factors in determining the complexity and prognosis for posterior urethral stenosis. Copyright © 2017. Published by Elsevier Inc.

  14. Randomized trial of low versus high carbon dioxide insufflation pressures in posterior retroperitoneoscopic adrenalectomy.

    Science.gov (United States)

    Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark

    2018-05-01

    Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Auxiliary partial liver transplantation

    NARCIS (Netherlands)

    C.B. Reuvers (Cornelis Bastiaan)

    1986-01-01

    textabstractIn this thesis studies on auxiliary partial liver transplantation in the dog and the pig are reported. The motive to perform this study was the fact that patients with acute hepatic failure or end-stage chronic liver disease are often considered to form too great a risk for successful

  16. Partial Remission Definition

    DEFF Research Database (Denmark)

    Andersen, Marie Louise Max; Hougaard, Philip; Pörksen, Sven

    2014-01-01

    OBJECTIVE: To validate the partial remission (PR) definition based on insulin dose-adjusted HbA1c (IDAA1c). SUBJECTS AND METHODS: The IDAA1c was developed using data in 251 children from the European Hvidoere cohort. For validation, 129 children from a Danish cohort were followed from the onset...

  17. Fundamental partial compositeness

    DEFF Research Database (Denmark)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Unde...

  18. Partially ordered models

    NARCIS (Netherlands)

    Fernandez, R.; Deveaux, V.

    2010-01-01

    We provide a formal definition and study the basic properties of partially ordered chains (POC). These systems were proposed to model textures in image processing and to represent independence relations between random variables in statistics (in the later case they are known as Bayesian networks).

  19. Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rissanen, Jorma

    1996-01-01

    Partially Hidden Markov Models (PHMM) are introduced. They differ from the ordinary HMM's in that both the transition probabilities of the hidden states and the output probabilities are conditioned on past observations. As an illustration they are applied to black and white image compression where...

  20. Honesty in partial logic

    NARCIS (Netherlands)

    W. van der Hoek (Wiebe); J.O.M. Jaspars; E. Thijsse

    1995-01-01

    textabstractWe propose an epistemic logic in which knowledge is fully introspective and implies truth, although truth need not imply epistemic possibility. The logic is presented in sequential format and is interpreted in a natural class of partial models, called balloon models. We examine the

  1. Endoscopic third ventriculostomy and posterior fossa tumors.

    Science.gov (United States)

    Di Rocco, Federico; Jucá, Carlos Eduardo; Zerah, Michel; Sainte-Rose, Christian

    2013-02-01

    The management of hydrocephalus associated with a posterior fossa tumor is debated. Some authors emphasize the advantages of an immediate tumor removal that may normalize the cerebrospinal fluid (CSF) dynamics. However, in clinical practice, the mere excision of the lesion has been demonstrated to be accompanied by a persisting hydrocephalus in about one third of the cases. Preoperative endoscopic third ventriculostomy (ETV) offers several advantages. It may control the intracranial pressure (ICP), avoid the necessity of an emergency procedure, allow appropriate scheduling of the operation for tumor removal, and eliminate the risks related to the presence of an external drainage. The procedure also reduces the incidence of postoperative hydrocephalus. A final advantage, more difficult to weight, but obvious to the neurosurgeon, is the possibility to remove the lesion with a relaxed brain and normal ICP. In the postoperative phase, ETV can be used in case of persisting hydrocephalus, both in patients who underwent only the excision of the tumor and in those whose preoperative ETV failed as a consequence of intraventricular bleeding with secondary closure of the stoma (redoETV). The main advantage of postoperative ETV is that the procedure is carried out only in case of persisting hydrocephalus; its use is consequently more selective than preoperative ETV. The disadvantage consists in the common use of an external CSF drainage in the first few postoperative days, which is necessary to control the pressure and for ruling out those cases that reach a spontaneous cure of the hydrocephalus. The authors review the criteria for patient selection and the results of ETV performed in case of hydrocephalus secondary to a posterior fossa tumor. Preoperative ETV constitutes an effective procedure for controlling the hydrocephalus associated with posterior fossa tumors. It might lower the rate of persistent postoperative hydrocephalus and result in a short hospital stay. Low

  2. Algebraic partial Boolean algebras

    International Nuclear Information System (INIS)

    Smith, Derek

    2003-01-01

    Partial Boolean algebras, first studied by Kochen and Specker in the 1960s, provide the structure for Bell-Kochen-Specker theorems which deny the existence of non-contextual hidden variable theories. In this paper, we study partial Boolean algebras which are 'algebraic' in the sense that their elements have coordinates in an algebraic number field. Several of these algebras have been discussed recently in a debate on the validity of Bell-Kochen-Specker theorems in the context of finite precision measurements. The main result of this paper is that every algebraic finitely-generated partial Boolean algebra B(T) is finite when the underlying space H is three-dimensional, answering a question of Kochen and showing that Conway and Kochen's infinite algebraic partial Boolean algebra has minimum dimension. This result contrasts the existence of an infinite (non-algebraic) B(T) generated by eight elements in an abstract orthomodular lattice of height 3. We then initiate a study of higher-dimensional algebraic partial Boolean algebras. First, we describe a restriction on the determinants of the elements of B(T) that are generated by a given set T. We then show that when the generating set T consists of the rays spanning the minimal vectors in a real irreducible root lattice, B(T) is infinite just if that root lattice has an A 5 sublattice. Finally, we characterize the rays of B(T) when T consists of the rays spanning the minimal vectors of the root lattice E 8

  3. All Zirconia: A New Material for Posteriors with Minimal Tooth Preparation

    Directory of Open Access Journals (Sweden)

    Asha M Rathod

    2014-01-01

    Full Text Available Background: Planning and executing the restorative rehabilitation of a decimated dentition is probably one of the most intellectually and technically demanding tasks being faced by a dentist. Full mouth rehabilitation involves restoring the dentate or a partially dentate mouth to provide an orderly pattern of occlusal contact and articulation that will optimize oral function, occlusal stability and esthetics. This case report demonstrates a full mouth rehabilitation of a patient for esthetically and functionally compromised dentition by a recently introduced ′metal-free′ restoration. The final prosthesis ensured a restoration resulting in predictable posterior disclusion and anterior guidance in harmony with the condylar path.

  4. Imaging of the posterior pelvic floor

    International Nuclear Information System (INIS)

    Stoker, Jaap; Bartram, Clive I.; Halligan, Steve

    2002-01-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  5. Imaging of the posterior pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Bartram, Clive I.; Halligan, Steve [Intestinal Imaging Centre, St. Mark' s Hospital, London (United Kingdom)

    2002-04-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  6. Elastic K-means using posterior probability.

    Science.gov (United States)

    Zheng, Aihua; Jiang, Bo; Li, Yan; Zhang, Xuehan; Ding, Chris

    2017-01-01

    The widely used K-means clustering is a hard clustering algorithm. Here we propose a Elastic K-means clustering model (EKM) using posterior probability with soft capability where each data point can belong to multiple clusters fractionally and show the benefit of proposed Elastic K-means. Furthermore, in many applications, besides vector attributes information, pairwise relations (graph information) are also available. Thus we integrate EKM with Normalized Cut graph clustering into a single clustering formulation. Finally, we provide several useful matrix inequalities which are useful for matrix formulations of learning models. Based on these results, we prove the correctness and the convergence of EKM algorithms. Experimental results on six benchmark datasets demonstrate the effectiveness of proposed EKM and its integrated model.

  7. Iodine-125 radiation of posterior uveal melanoma

    International Nuclear Information System (INIS)

    Packer, S.

    1987-01-01

    Twenty-eight cases of posterior choroidal melanoma were treated with iodine-125 in gold eye plaques. Eleven cases were located within 3.0 mm of the optic nerve (group A), nine were within 3.0 mm of the fovea (group B), and eight were within 3.0 mm of the optic nerve and fovea (group C). The mean follow-up of group A was 46.3 months; group B, 25.5 months; and group C, 42.7 months. Complications included macular edema, cataract and tumor growth. Visual acuity remained within two lines of that tested preoperatively for 4 of 11 patients in group A, 4 of 9 in group B, and 5 of 8 in group C. These results with iodine-125 suggest it as an appropriate treatment for patients with choroidal melanoma located near optic nerve and/or macula

  8. Iodine-125 radiation of posterior uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Packer, S.

    1987-12-01

    Twenty-eight cases of posterior choroidal melanoma were treated with iodine-125 in gold eye plaques. Eleven cases were located within 3.0 mm of the optic nerve (group A), nine were within 3.0 mm of the fovea (group B), and eight were within 3.0 mm of the optic nerve and fovea (group C). The mean follow-up of group A was 46.3 months; group B, 25.5 months; and group C, 42.7 months. Complications included macular edema, cataract and tumor growth. Visual acuity remained within two lines of that tested preoperatively for 4 of 11 patients in group A, 4 of 9 in group B, and 5 of 8 in group C. These results with iodine-125 suggest it as an appropriate treatment for patients with choroidal melanoma located near optic nerve and/or macula.

  9. Posterior Reversible Encephalopathy Syndrome in Our Setup

    International Nuclear Information System (INIS)

    Ahmad, I.; Zubair, U. B.; Mumtaz, H.; Yousaf, M. A.; Muhammad, W. W.

    2013-01-01

    Objectives: To assess the clinical presentation and neuroimaging abnormalities in a series of patients diagnosed as posterior reversible encephalopathy syndrome at Military Hospital Rawalpindi. Study Design: Case series study. Place and Duration: Study was carried out at Military Hospital Rawalpindi form December 01st, 2011 to May 31st, 2012. Patients and Methods: Study included all the cases of the Posterior reversible encephalopathy syndrome (PRES) admitted in the wards and intensive care unit (ITC). Neuroimaging was done and all the studies were reviewed by independent neuroradiologist. Different clinical and laboratory variables were also studied and correlated with neuroimaging. Follow up ws done to look for the prognosis. Results: Of the seven patients labelled as PRES two were male and five were female. Two patients were over 50 years of age, out of them one was male and one was female. One patient had end stage renal disease (ESRD) secondary to diabetes mellitus (DM) and hypertension (HTN), one had eclampsia, one had pregnancy-induced hypertension (PIH) and one had just uncontrolled HTN. Peak spontaneous bacterial peritonitis (SBP) in 5 cases was 210 mm of Hg, four of which had seizures. Rest two had spontaneous bacterial peritonitis (SBP) of 160 out of which one developed seizures. Total out of 7, 5 experienced seizures and altered conscious state, rest two only had confusion. One patient had papilloedema. Follow up was done after 06 weeks, 02 patients died, 05 remained alive and symptoms of PRES had vanished. Conclusion: PRES is a neurological emergency, presents with a variety of symptoms and has a specific neuroimaging pattern. Early recognition and prompt treatment result in a good neurological outcome. (author)

  10. Distrofia corneana polimorfa posterior em Síndrome de Alport

    OpenAIRE

    Godoy, Flavia Ribeiro Monteiro de; Qahtani, Elham Al; Lyons, Christopher J.

    2016-01-01

    ABSTRACT We describe a six-year-old boy with a history of hematuria, posterior polymorphous corneal dystrophy and dots and fleck retinopathy. Alport syndrome should be ruled out in patients presenting with posterior polymorphous corneal dystrophy or anterior lenticonus and a family history of renal disease. RESUMO Descrevemos um paciente de 6 anos de idade com história de hematúria, distrofia corneana polimorfa posterior e retinopatia em "dots and flecks". Síndrome de Alport deve ser exclu...

  11. Minimally invasive surgical approach to treat posterior urethral diverticulum

    Directory of Open Access Journals (Sweden)

    Ossamah Alsowayan

    2015-01-01

    Full Text Available Urethral diverticulum is a localized saccular or fusiform out-pouching of the urethra. It may occur at any point along the urethra in both male and females. Male urethral diverticulum is rare, and could be either congenital or acquired, anterior or posterior. The mainstay treatment of posterior urethral diverticulum (PUD is the open surgical approach. Here we discuss our minimally invasive surgical approach (MIS in managing posterior urethral diverticulum.

  12. Biomechanical study: resistance comparison of posterior antiglide plate and lateral plate on synthetic bone models simulating Danis-Weber B malleolar fractures

    Directory of Open Access Journals (Sweden)

    Bruna Buscharino

    2013-06-01

    Full Text Available OBJECTIVE : The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®. Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05. CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate.

  13. Posterior longitudinal ligament status in cervical spine bilateral facet dislocations

    International Nuclear Information System (INIS)

    Carrino, John A.; Manton, Geoffrey L.; Morrison, William B.; Flanders, Adam E.; Vaccaro, Alex R.; Schweitzer, Mark E.

    2006-01-01

    It is generally accepted that cervical spine bilateral facet dislocation results in complete disruption of the posterior longitudinal ligament. The goal of this study was to evaluate the integrity of numerous spine-stabilizing structures by MRI, and to determine if any associations between injury patterns exist with respect to the posterior longitudinal ligament status. Retrospective case series. A retrospective review was performed of 30 cervical spine injury subjects with bilateral facet dislocation. Assessment of 1.5T MRI images was carried out for: intervertebral disc disruption, facet fracture, and ligamentous disruption. Statistical analyses were performed to evaluate for associations between various injury patterns and posterior longitudinal ligament status. The frequency of MRI abnormalities was: anterior longitudinal ligament disruption (26.7%), disc herniation or disruption (90%), posterior longitudinal ligament disruption (40%), facet fracture (63.3%) and disruption of the posterior column ligament complex (97%). There were no significant associations between injury to the posterior longitudinal ligament and other structures. Compared to surgical reports, MRI was accurate for determining the status for 24 of 26 ligaments (three of three anterior longitudinal ligament, seven of nine posterior longitudinal ligament, and 14 of 14 posterior column ligament complex) but generated false negatives in two instances (in both MRI showed an intact posterior longitudinal ligament that was torn at surgery). (orig.)

  14. Posterior mediastinal teratoma diagnosis by computerized tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yeon Myung; Im, Chung Kie; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-09-15

    Teratomas, usually arising in the anterior mediastinum, are very uncommon in the posterior mediastinum. Embryologic development of anterior mediastinal teratoma is thought to be from thymic anlage which descends from the third bronchial cleft and pouch, while that of posterior mediastinal teratoma is thought to be from the remnant of notochord. CT findings of posterior mediastinal teratomas are not different from teratomas elsewhere, containing fat, calcification, soft tissue and thick walled cyst. Ultrasonographic findings are mixed echogenic mass containing cystic portion, highly reflective solid portion and area of acoustic shadowing. Authors recently experienced 2 cases of surgically proven posterior mediastinal teratoma and report with review of literature.

  15. Posterior mediastinal teratoma diagnosis by computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Choo, Yeon Myung; Im, Chung Kie; Yeon, Kyung Mo; Han, Man Chung

    1984-01-01

    Teratomas, usually arising in the anterior mediastinum, are very uncommon in the posterior mediastinum. Embryologic development of anterior mediastinal teratoma is thought to be from thymic anlage which descends from the third bronchial cleft and pouch, while that of posterior mediastinal teratoma is thought to be from the remnant of notochord. CT findings of posterior mediastinal teratomas are not different from teratomas elsewhere, containing fat, calcification, soft tissue and thick walled cyst. Ultrasonographic findings are mixed echogenic mass containing cystic portion, highly reflective solid portion and area of acoustic shadowing. Authors recently experienced 2 cases of surgically proven posterior mediastinal teratoma and report with review of literature.

  16. Partially composite Higgs models

    DEFF Research Database (Denmark)

    Alanne, Tommi; Buarque Franzosi, Diogo; Frandsen, Mads T.

    2018-01-01

    We study the phenomenology of partially composite-Higgs models where electroweak symmetry breaking is dynamically induced, and the Higgs is a mixture of a composite and an elementary state. The models considered have explicit realizations in terms of gauge-Yukawa theories with new strongly...... interacting fermions coupled to elementary scalars and allow for a very SM-like Higgs state. We study constraints on their parameter spaces from vacuum stability and perturbativity as well as from LHC results and find that requiring vacuum stability up to the compositeness scale already imposes relevant...... constraints. A small part of parameter space around the classically conformal limit is stable up to the Planck scale. This is however already strongly disfavored by LHC results. in different limits, the models realize both (partially) composite-Higgs and (bosonic) technicolor models and a dynamical extension...

  17. Simplified solutions of the Cox-Thompson inverse scattering method at fixed energy

    International Nuclear Information System (INIS)

    Palmai, Tamas; Apagyi, Barnabas; Horvath, Miklos

    2008-01-01

    Simplified solutions of the Cox-Thompson inverse quantum scattering method at fixed energy are derived if a finite number of partial waves with only even or odd angular momenta contribute to the scattering process. Based on new formulae various approximate methods are introduced which also prove applicable to the generic scattering events

  18. Photogenic partial seizures.

    Science.gov (United States)

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  19. Arthroscopic partial medial meniscectomy

    Directory of Open Access Journals (Sweden)

    Dašić Žarko

    2011-01-01

    Full Text Available Background/Aim. Meniscal injuries are common in professional or recreational sports as well as in daily activities. If meniscal lesions lead to physical impairment they usually require surgical treatment. Arthroscopic treatment of meniscal injuries is one of the most often performed orthopedic operative procedures. Methods. The study analyzed the results of arthroscopic partial medial meniscectomy in 213 patients in a 24-month period, from 2006, to 2008. Results. In our series of arthroscopically treated medial meniscus tears we noted 78 (36.62% vertical complete bucket handle lesions, 19 (8.92% vertical incomplete lesions, 18 (8.45% longitudinal tears, 35 (16.43% oblique tears, 18 (8.45% complex degenerative lesions, 17 (7.98% radial lesions and 28 (13.14% horisontal lesions. Mean preoperative International Knee Documentation Committee (IKDC score was 49.81%, 1 month after the arthroscopic partial medial meniscectomy the mean IKDC score was 84.08%, and 6 months after mean IKDC score was 90.36%. Six months after the procedure 197 (92.49% of patients had good or excellent subjective postoperative clinical outcomes, while 14 (6.57% patients subjectively did not notice a significant improvement after the intervention, and 2 (0.93% patients had no subjective improvement after the partial medial meniscectomy at all. Conclusion. Arthroscopic partial medial meniscetomy is minimally invasive diagnostic and therapeutic procedure and in well selected cases is a method of choice for treatment of medial meniscus injuries when repair techniques are not a viable option. It has small rate of complications, low morbidity and fast rehabilitation.

  20. Fixed telephony evolution at CERN

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    The heart of CERN’s telephony infrastructure consists of the Alcatel IP-PBX that links CERN’s fixed line phones, Lync softphones and CERN’s GSM subscribers to low-cost local and international telephony services. The PABX infrastructure also supports the emergency “red telephones” in the LHC tunnel and provides vital services for the Fire and Rescue Service and the CERN Control Centre. Although still reliable, the Alcatel hardware is increasingly costly to maintain and looking increasingly outmoded in a market where open source solutions are increasingly dominant. After presenting an overview of the Alcatel PABX and the services it provides, including innovative solutions such as the Closed User Group for our mobile telephony services, we present a possible architecture for a software based system designed to meet tomorrow’s communication needs and describe how the introduction of open-source call routers based on the SIP protocol and Session Border Controllers (SBC) could foster the introduction...

  1. Fixed type incore measuring device

    International Nuclear Information System (INIS)

    Oda, Naotaka; Ito, Hitoshi; Maeda, Hiroyuki

    1998-01-01

    The present invention concerns a measuring device using gamma thermometers to be used in a BWR type reactor. An input switch is inserted to the vicinity of a detection signal input portion of a signal cable connecting GT with the detection signal input portion of a fixed type incore measuring device, and a loop resistance measuring means is disposed to the input switch on the side of the GT by way of a measurement switch. Upon measuring loop resistance, the GT measuring circuit is switched from the detection signal input portion to the loop resistance measuring means by a switching operation of the input switch and the measurement switch thereby enabling to confirm the value of the loop resistance. In addition, the lowering of the voltage in the loop resistance is compensated to confirm the accurate measurement values to be used thereby enabling to measure GT detection signals accurately. A diagnosing means for diagnosing the state of GT based on the results of the measurement for the loop resistance is disposed, and the results are reported to an operator. (N.H.)

  2. Partial and complete tear of the anterior cruciate ligament. Direct and indirect MR signs

    International Nuclear Information System (INIS)

    Chen, W.T.; Tu, H.Y.; Chen, R.C.; Shih, T.T.F.; Shau, W.Y.

    2002-01-01

    Purpose: To analyze MR direct and indirect signs for knees with anterior cruciate ligament (ACL) partial or complete tear. Material and Methods: According to documented MR direct and indirect signs for ACL tear, we retrospectively reviewed the incidence of those signs in 15 partial ACL tear and 17 complete ACL tear patients. The findings were also compared with duration of injury (less or more than 6 weeks, as acute or chronic stages). Results: A residual straight and tight ACL fiber in at least one pulse sequence was more frequently detected in partial ACL tears. The empty notch sign, a wavy contour of ACL, bone contusion at lateral compartment and lateral meniscus posterior horn tear were significantly more frequently seen in complete tear cases. The posterior cruciate ligament angle in chronic complete ACL tear cases (109 deg ±20 deg) had a tendency to be less than in chronic partial ACL tear cases (119 deg ±18 deg). Conclusion: The empty notch sign, a wavy ACL, bone contusion, and posterior horn of lateral meniscus tears are suggestive of a complete ACL tear. A residual straight and tight ACL fiber seen in at least one image section is a helpful sign to diagnosis of partial ACL tear. In the acute ACL injury stage, a focal increase of the ACL signal intensity is more suggestive of a partial ACL tear

  3. Hierarchical partial order ranking

    International Nuclear Information System (INIS)

    Carlsen, Lars

    2008-01-01

    Assessing the potential impact on environmental and human health from the production and use of chemicals or from polluted sites involves a multi-criteria evaluation scheme. A priori several parameters are to address, e.g., production tonnage, specific release scenarios, geographical and site-specific factors in addition to various substance dependent parameters. Further socio-economic factors may be taken into consideration. The number of parameters to be included may well appear to be prohibitive for developing a sensible model. The study introduces hierarchical partial order ranking (HPOR) that remedies this problem. By HPOR the original parameters are initially grouped based on their mutual connection and a set of meta-descriptors is derived representing the ranking corresponding to the single groups of descriptors, respectively. A second partial order ranking is carried out based on the meta-descriptors, the final ranking being disclosed though average ranks. An illustrative example on the prioritisation of polluted sites is given. - Hierarchical partial order ranking of polluted sites has been developed for prioritization based on a large number of parameters

  4. Distrofia corneana policromática posterior Polychromatic posterior corneal dystrophy

    Directory of Open Access Journals (Sweden)

    Patrick Frensel de Moraes Tzelikis

    2007-08-01

    Full Text Available Os autores descrevem quatro raros casos de distrofia corneana policromática posterior, ainda não descrito na literatura nacional. Observam-se opacidades puntiformes, policromáticas, de tamanho uniforme, localização estromal profunda, distribuídas de limbo a limbo e que não interferem na acuidade visual. É apresentada uma revisão dos casos de distrofia pré-Descemet existentes na literatura.The authors describe four rare cases of polychromatic posterior corneal dystrophy, not describe in national literature. The opacities are deep in the stroma, dotlike, polychromatic, uniform in size, distributed from limbus to limbus, leading no reduction in visual acuity. It is also presented a bibliographic review of pre-Descemet's dystrophy.

  5. An approach for fixed coefficient RNS-based FIR filter

    Science.gov (United States)

    Srinivasa Reddy, Kotha; Sahoo, Subhendu Kumar

    2017-08-01

    In this work, an efficient new modular multiplication method for {2k-1, 2k, 2k+1-1} moduli set is proposed to implement a residue number system (RNS)-based fixed coefficient finite impulse response filter. The new multiplication approach reduces the number of partial products by using pre-loaded product block. The reduction in partial products with the proposed modular multiplication improves the clock frequency and reduces the area and power as compared with the conventional modular multiplication. Further, the present approach eliminates a binary number to residue number converter circuit, which is usually needed at the front end of RNS-based system. In this work, two fixed coefficient filter architectures with the new modular multiplication approach are proposed. The filters are implemented using Verilog hardware description language. The United Microelectronics Corporation 90 nm technology library has been used for synthesis and the results area, power and delay are obtained with the help of Cadence register transfer level compiler. The power delay product (PDP) is also considered for performance comparison among the proposed filters. One of the proposed architecture is found to improve PDP gain by 60.83% as compared with the filter implemented with conventional modular multiplier. The filters functionality is validated with the help of Altera DSP Builder.

  6. Influence of fragment size and postoperative joint congruency on long-term outcome of posterior malleolar fractures.

    Science.gov (United States)

    Drijfhout van Hooff, Cornelis Christiaan; Verhage, Samuel Marinus; Hoogendoorn, Jochem Maarten

    2015-06-01

    One of the factors contributing to long-term outcome of posterior malleolar fractures is the development of osteoarthritis. Based on biomechanical, cadaveric, and small population studies, fixation of posterior malleolar fracture fragments (PMFFs) is usually performed when fragment size exceeds 25-33%. However, the influence of fragment size on long-term clinical and radiological outcome size remains unclear. A retrospective cohort study of 131 patients treated for an isolated ankle fracture with involvement of the posterior malleolus was performed. Mean follow-up was 6.9 (range, 2.5-15.9) years. Patients were divided into groups depending on size of the fragment, small (25%, n = 25), and presence of step-off after operative treatment. We have compared functional outcome measures (AOFAS, AAOS), pain (VAS), and dorsiflexion restriction compared to the contralateral ankle and the incidence of osteoarthritis on X-ray. There were no nonunions, 56% of patients had no radiographic osteoarthritis, VAS was 10 of 100, and median clinical score was 90 of 100. More osteoarthritis occurred in ankle fractures with medium and large PMFFs compared to small fragments (small 16%, medium 48%, large 54%; P = .006). Also when comparing small with medium-sized fragments (P = .02), larger fragment size did not lead to a significantly decreased function (median AOFAS 95 vs 88, P = .16). If the PMFF size was >5%, osteoarthritis occurred more frequently when there was a postoperative step-off ≥1 mm in the tibiotalar joint surface (41% vs 61%, P = .02) (whether the posterior fragment had been fixed or not). In this group, fixing the PMFF did not influence development of osteoarthritis. However, in 42% of the cases with fixation of the fragment a postoperative step-off remained (vs 45% in the group without fixation). Osteoarthritis is 1 component of long-term outcome of malleolar fractures, and the results of this study demonstrate that there was more radiographic osteoarthritis in

  7. Implant-supported removable partial dentures in the mandible : A 3-16 year retrospective study

    NARCIS (Netherlands)

    Jensen, Charlotte; Meijer, Henny J A; Raghoebar, Gerry M; Kerdijk, Wouter; Cune, Marco S

    PURPOSE: The purpose of this retrospective study was to assess performance, together with biological and technical complications, of implant-supported removable partial dentures (ISRPD) in mandibular Kennedy class I situations with implants placed in the anterior or posterior position. METHODS: 23

  8. Implant-supported removable partial dentures in the mandible : A 3-16 year retrospective study

    NARCIS (Netherlands)

    Jensen, Charlotte; Meijer, Henny J. A.; Raghoebar, Gerry M.; Kerdijk, Wouter; Cune, Marco S.

    Purpose: The purpose of this retrospective study was to assess performance, together with biological and technical complications, of implant-supported removable partial dentures (ISRPD) in mandibular Kennedy class I situations with implants placed in the anterior or posterior position. Methods: 23

  9. Frequency and determinants for hemorrhagic transformation of posterior cerebral stroke : Posterior ischemic stroke and hemorrhagic transformation.

    Science.gov (United States)

    Valentino, Francesca; Gentile, Luana; Terruso, Valeria; Mastrilli, Sergio; Aridon, Paolo; Ragonese, Paolo; Sarno, Caterina; Savettieri, Giovanni; D'Amelio, Marco

    2017-11-13

    hemorrhagic transformation is a threatening ischemic stroke complication. Frequency of hemorrhagic transformation differs greatly among studies, and its risk factors have been usually studied in patients with anterior ischemic stroke who received thrombolytic therapy. We evaluated, in a hospital-based series of patients with posterior ischemic stroke not treated with thrombolysis, frequency and risk factors of hemorrhagic transformation. Patients with posterior circulation stroke were seen in our Department during the period January 2004 to December 2009. Demographic and clinical information were collected. We estimated risk for spontaneous hemorrhagic transformation by means of uni- and multivariate logistic regression analyses. 119 consecutive patients were included (73 males, 61.3%). Hemorrhagic transformation was observed in 7 patients (5.9%). Only clinical worsening was significantly associated with hemorrhagic transformation (OR 6.8, 95% CI 1.3-34.5). Our findings indicate that patients with posterior have a low risk of spontaneous hemorrhagic transformation, suggesting that these patients might have greater advantage from intravenous thrombolysis.

  10. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing

    2013-12-01

    To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.

  11. Combination of Intravitreal Ranibizumab and Laser Photocoagulation for Aggressive Posterior Retinopathy of Prematurity

    Directory of Open Access Journals (Sweden)

    Ágata Mota

    2012-04-01

    Full Text Available Purpose: To report on 2 cases of aggressive posterior retinopathy of prematurity (ROP treated with intravitreal ranibizumab (Lucentis® and laser photocoagulation. Methods: Two premature females, born at 25 and 26 weeks’ gestation with a birth weight of 530 and 550 g, respectively, with aggressive posterior ROP received combined treatment with laser photocoagulation and intravitreal ranibizumab (0.3 mg [30 µl] to each eye. Structural outcomes were evaluated by indirect ophthalmoscopy and documented by retinography. Results: An intravitreal injection was made at 34 weeks of postmenstrual age in the first case, followed by laser photocoagulation 1 week later. There was a partial regression of ROP with treatment. Five weeks later, neovascularization regrowth with bleeding in both eyes (intraretinal and subhyaloid occurred and retreatment with combined therapy was performed. In the second case, single therapy with laser photocoagulation was made at 34 weeks of postmenstrual age. In spite of the confluent photocoagulation in the avascular area, progression to 4A ROP stage occurred 1 week later. Both eyes were retreated 1 week later with intravitreal ranibizumab and laser photocoagulation. Treatment resulted in ROP regression in both cases. There were no signs of systemic or ocular adverse side effects. Conclusion: The cases presented show that combination therapy of indirect laser photocoagulation and intravitreal ranibizumab can be effective in the management of aggressive posterior ROP. Further investigation on anti-VEGF safety in premature infants is necessary . Additional studies are needed to define the role of anti-VEGF in ROP treatment.

  12. Common fixed points for weakly compatible maps

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    In 1976, Jungck [4] proved a common fixed point theorem for commuting maps generalizing the Banach's fixed point theorem, which states that, 'let (X, d) be a complete metric space. If T satisfies d(Tx,Ty) ≤ kd(x,y) for each x,y ∈ X where 0 ≤ k < 1, then T has a unique fixed point in X'. This theorem has many applications, ...

  13. Infra-red fixed points in supersymmetry

    Indian Academy of Sciences (India)

    ¾c /font>, and c stands for the color quadratic Casimir of the field. Fixed points arise when R* ¼ or when R*. /nobr>. ´S-½. µ ´r ·b¿µ. The stability of the solutions may be tested by linearizing the system about the fixed points. For the non-trivial fixed points we need to consider the eigenvalues of the stability matrix whose ...

  14. Impact of Platform Switching on Peri-Implant Bone Remodeling around Short Implants in the Posterior Region, 1-Year Results from a Split-Mouth Clinical Trial

    NARCIS (Netherlands)

    Telleman, Gerdien; Raghoebar, Gerry M.; Vissink, Arjan; Meijer, Henny J. A.

    Aim: To assess the effect of platform switching on peri-implant bone remodeling around short implants (8.5mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients. Materials and Methods: Seventeen patients with one or more missing teeth at both sides in

  15. Fixed point theorems in spaces and -trees

    Directory of Open Access Journals (Sweden)

    Kirk WA

    2004-01-01

    Full Text Available We show that if is a bounded open set in a complete space , and if is nonexpansive, then always has a fixed point if there exists such that for all . It is also shown that if is a geodesically bounded closed convex subset of a complete -tree with , and if is a continuous mapping for which for some and all , then has a fixed point. It is also noted that a geodesically bounded complete -tree has the fixed point property for continuous mappings. These latter results are used to obtain variants of the classical fixed edge theorem in graph theory.

  16. Factors influencing bonding fixed restorations

    Directory of Open Access Journals (Sweden)

    Medić Vesna

    2008-01-01

    Full Text Available INTRODUCTION Crown displacement often occurs because the features of tooth preparations do not counteract the forces directed against restorations. OBJECTIVE The purpose of this study was to evaluate the effect of preparation designs on retention and resistance of fixed restorations. METHOD The study was performed on 64 differently sized stainless steel dies. Also, caps which were used for evaluated retention were made of stainless steel for each die. After cementing the caps on experimental dies, measuring of necessary tensile forces to separate cemented caps from dies was done. Caps, which were made of a silver-palladium alloy with a slope of 60° to the longitudinal axis formed on the occlusal surface, were used for evaluating resistance. A sudden drop in load pressure recorded by the test machine indicated failure for that cap. RESULTS A significant difference was found between the tensile force required to remove the caps from the dies with different length (p<0.05 and different taper (p<0.01. The greatest retentive strengths (2579.2 N and 2989.8 N were noticed in experimental dies with the greatest length and smallest taper. No statistically significant (p>0.05 differences were found between tensile loads for caps cemented on dies with different diameter. Although there was an apparent slight increase in resistance values for caps on dies with smaller tapers, the increase in resistance for those preparation designs was not statistically significant. There was a significant difference among the resistance values for caps on dies with different length (p<0.01 and diameter (p<0.05. CONCLUSION In the light of the results obtained, it could be reasonably concluded that retention and resistance of the restoration is in inverse proportion to convergence angle of the prepared teeth. But, at a constant convergence angle, retention and resistance increase with rising length and diameter.

  17. Clinical evaluation of failures in removable partial dentures.

    Science.gov (United States)

    Jorge, Janaina H; Quishida, Cristiane C C; Vergani, Carlos E; Machado, Ana L; Pavarina, Ana C; Giampaolo, Eunice T

    2012-01-01

    The aim of this clinical study was to evaluate the effects of removable partial dentures on the support tissues and changes occurring in lower tooth-supported and bilateral distal-extension dentures, 5 years after placement. The study involved analysis of a total of 53 patients who received prosthetic treatment for removable partial dentures. The patients were divided into two groups. In group 1, the patients had a completely edentulous maxilla and an edentulous area with natural teeth remaining in both the anterior and posterior regions. In group 2, the patients had a completely edentulous maxilla and partially edentulous mandible with preserved anterior teeth. Tooth mobility, prevalence of caries, fracture of the abutment teeth, fracture and/or deformation of the removable partial denture components and stability of the denture base were evaluated. The use of a removable partial denture increased tooth mobility, reduced the prevalence of caries, and did not cause loss or fracture of the abutments or damage to their components, when compared with the baseline. It was concluded that there was no difference between the groups as evaluated in terms of tooth mobility, prevalence of caries, loss and fracture of the abutments or damage to the components of the removable partial denture.

  18. Paratrooper's ankle fracture: posterior malleolar fracture.

    Science.gov (United States)

    Young, Ki Won; Kim, Jin-su; Cho, Jae Ho; Kim, Hyung Seuk; Cho, Hun Ki; Lee, Kyung Tai

    2015-03-01

    We assessed the frequency and types of ankle fractures that frequently occur during parachute landings of special operation unit personnel and analyzed the causes. Fifty-six members of the special force brigade of the military who had sustained ankle fractures during parachute landings between January 2005 and April 2010 were retrospectively analyzed. The injury sites and fracture sites were identified and the fracture types were categorized by the Lauge-Hansen and Weber classifications. Follow-up surveys were performed with respect to the American Orthopedic Foot and Ankle Society ankle-hindfoot score, patient satisfaction, and return to preinjury activity. The patients were all males with a mean age of 23.6 years. There were 28 right and 28 left ankle fractures. Twenty-two patients had simple fractures and 34 patients had comminuted fractures. The average number of injury and fractures sites per person was 2.07 (116 injuries including a syndesmosis injury and a deltoid injury) and 1.75 (98 fracture sites), respectively. Twenty-three cases (41.07%) were accompanied by posterior malleolar fractures. Fifty-five patients underwent surgery; of these, 30 had plate internal fixations. Weber type A, B, and C fractures were found in 4, 38, and 14 cases, respectively. Based on the Lauge-Hansen classification, supination-external rotation injuries were found in 20 cases, supination-adduction injuries in 22 cases, pronation-external rotation injuries in 11 cases, tibiofibular fractures in 2 cases, and simple medial malleolar fractures in 2 cases. The mean follow-up period was 23.8 months, and the average follow-up American Orthopedic Foot and Ankle Society ankle-hindfoot score was 85.42. Forty-five patients (80.36%) reported excellent or good satisfaction with the outcome. Posterior malleolar fractures occurred in 41.07% of ankle fractures sustained in parachute landings. Because most of the ankle fractures in parachute injuries were compound fractures, most cases had to

  19. Partially massless higher-spin theory

    Energy Technology Data Exchange (ETDEWEB)

    Brust, Christopher [Perimeter Institute for Theoretical Physics,31 Caroline St. N, Waterloo, Ontario N2L 2Y5 (Canada); Hinterbichler, Kurt [CERCA, Department of Physics, Case Western Reserve University,10900 Euclid Ave, Cleveland, OH 44106 (United States)

    2017-02-16

    We study a generalization of the D-dimensional Vasiliev theory to include a tower of partially massless fields. This theory is obtained by replacing the usual higher-spin algebra of Killing tensors on (A)dS with a generalization that includes “third-order” Killing tensors. Gauging this algebra with the Vasiliev formalism leads to a fully non-linear theory which is expected to be UV complete, includes gravity, and can live on dS as well as AdS. The linearized spectrum includes three massive particles and an infinite tower of partially massless particles, in addition to the usual spectrum of particles present in the Vasiliev theory, in agreement with predictions from a putative dual CFT with the same symmetry algebra. We compute the masses of the particles which are not fixed by the massless or partially massless gauge symmetry, finding precise agreement with the CFT predictions. This involves computing several dozen of the lowest-lying terms in the expansion of the trilinear form of the enlarged higher-spin algebra. We also discuss nuances in the theory that occur in specific dimensions; in particular, the theory dramatically truncates in bulk dimensions D=3,5 and has non-diagonalizable mixings which occur in D=4,7.

  20. Partially massless higher-spin theory

    International Nuclear Information System (INIS)

    Brust, Christopher; Hinterbichler, Kurt

    2017-01-01

    We study a generalization of the D-dimensional Vasiliev theory to include a tower of partially massless fields. This theory is obtained by replacing the usual higher-spin algebra of Killing tensors on (A)dS with a generalization that includes “third-order” Killing tensors. Gauging this algebra with the Vasiliev formalism leads to a fully non-linear theory which is expected to be UV complete, includes gravity, and can live on dS as well as AdS. The linearized spectrum includes three massive particles and an infinite tower of partially massless particles, in addition to the usual spectrum of particles present in the Vasiliev theory, in agreement with predictions from a putative dual CFT with the same symmetry algebra. We compute the masses of the particles which are not fixed by the massless or partially massless gauge symmetry, finding precise agreement with the CFT predictions. This involves computing several dozen of the lowest-lying terms in the expansion of the trilinear form of the enlarged higher-spin algebra. We also discuss nuances in the theory that occur in specific dimensions; in particular, the theory dramatically truncates in bulk dimensions D=3,5 and has non-diagonalizable mixings which occur in D=4,7.

  1. Epileptic seizures in patients with a posterior circulation infarct

    Directory of Open Access Journals (Sweden)

    Yüksel Kaplan

    2014-08-01

    Full Text Available OBJECTIVE: The aim of this study was to investigate the frequency of seizures and the clinical features of patients with seizures related to a posterior circulation infarct (POCI. METHODS: We reviewed all ischemic stroke patients admitted to our clinic between January 2011 and January 2012. The patients’ database information was retrospectively analyzed. Fifty-five patients with a POCI were included in the study. We reviewed all patients with epileptic seizures related to a POCI. Age, gender, recurrent stroke, risk factors, etiology, radiographic localization, the seizure type and onset time, and the electroencephalographic findings of patients were evaluated. We excluded all patients who had precipitating conditions during seizures such as taking drugs, acid-base disturbances, electrolyte imbalance, and history of epilepsy. RESULTS: Seizures were observed in four patients (3 male, 1 female with a POCI related epileptic seizures (7.2%. The etiology of strokes was cardiac-embolic in 3 patients and vertebral artery dissection in 1 patient. Seizures occurred in 2 patients as presenting finding, in 1 patient within 7 days, and 1 patient within 28 days. Primary generalized tonic-clonic seizures occurred in 3 patients and simple partial seizures with secondary generalization in 1 patient. Three patients had cerebellum infarction at the left hemisphere. One patient had lateral medullary infarction at the right side. The electroencephalographic findings of patients were normal. CONCLUSION: Studies involving patients with seizures related to a POCI are novel and few in number. Three patients with seizure had cerebellum infarction. The cerebellum in these patients may contribute via different mechanisms over seizure activity.

  2. [Extension of (extremely) shortened dental arches by fixed or removable partial dentures

    NARCIS (Netherlands)

    Witter, D.J.; Hoefnagel, R.A.; Snoek, P.A.; Creugers, N.H.J.

    2009-01-01

    Whether a shortened dental arch needs to be extended depends on the degree of the shortening. Four categories of shortened dental arches can be distinguished: 1. slightly shortened dental arches; 2. moderately shortened dental arches; 3. extremely shortened dental arches; and 4. asymmetrical

  3. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    OpenAIRE

    Saisadan, D.; Manimaran, P.; Meenapriya, P. K.

    2016-01-01

    Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, ...

  4. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture.

    Science.gov (United States)

    Saisadan, D; Manimaran, P; Meenapriya, P K

    2016-10-01

    Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties - flexural strength, compressive strength, and color stability. The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan). It was inferred from the study that no one material was superior in all three tested parameters.

  5. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    Directory of Open Access Journals (Sweden)

    D Saisadan

    2016-01-01

    Full Text Available Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composites: Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed Crowns: Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. Aims and Objectives: The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties – flexural strength, compressive strength, and color stability. Materials and Methods: The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan. Result: It was inferred from the study that no one material was superior in all three tested parameters.

  6. Effect of polyester fiber reinforcement on the mechanical properties of interim fixed partial dentures

    Directory of Open Access Journals (Sweden)

    N. Gopichander

    2015-10-01

    Conclusion: Within the limitations of this study, polyester fiber reinforcements improved the mechanical properties of heat-polymerized PMMA, cold-polymerized PMMA, and bis-acrylic provisional FPD materials.

  7. Posterior perforation of gastric ulcer: a rare surgical emergency ...

    African Journals Online (AJOL)

    BACKGROUND:Gastric ulcer perforation is a rare surgical emergency.Posterior gastric ulcer is even rarer and usually has a delayed presentation with attendant greater morbidity and mortality. AIM:To report a case of posterior perforation of gastric ulcer and review the literature. CASE REPORT:A 65yr old driver was seen in ...

  8. Early results of two methods of posterior spinal stabilization in ...

    African Journals Online (AJOL)

    2013-04-17

    Apr 17, 2013 ... Discussion. PSR has become the gold standard in posterior spinal fusion techniques. Its success has revolutionized spinal surgery. The Advantages include three column fusion as against one column fusion as is seen in other posterior fusion techniques like Rogers and Bohlman's techniques.[9‑13] Other.

  9. Bilateral, posterior parietal polymicrogyria as part of speech therapy ...

    African Journals Online (AJOL)

    SA Journal of Radiology ... Magnetic resonance imaging (MRI) has been associated with either diffuse polymicrogyria around the entire extent of the sylvian fissure or in the posterior aspects of the parietal regions, in which case it is called posterior parietal ... This article discusses the possible embryological origin of these

  10. Difficult management of posterior urethra gunshot wound combined ...

    African Journals Online (AJOL)

    Posterior urethra gunshot wounds are poorly described in the literature. They are often associated with pelvic vital lesions making difficult early repair of urethral injuries. They can be complicated by urethrorectal fistula, which makes their management more complicated. We report a new case of posterior urethra disruption ...

  11. Delayed primary realignment of posterior urethral rupture | Shittu ...

    African Journals Online (AJOL)

    The treatment of acute posterior urethral rupture is controversial. Twelve patients who presented with acute posterior urethral rupture over a five--year period were treated by delayed primary realignment of the injury. The technique of this procedure and the outcome are the subject of this presentation. Eight patients had ...

  12. Pseudoaneurysm of the posterior circumflex humeral artery diagnosed by sonography

    DEFF Research Database (Denmark)

    Damgaard, Bodil; Court-Payen, Michel; Larsen, Lone

    2009-01-01

    with a painless, nonpulsatile mass in the posterior shoulder region and was suspected of a malignant soft-tissue tumor. Sonography, including power Doppler imaging, demonstrated a pseudoaneurysm, with the intralesional blood-filled cavity developed from the posterior circumflex humeral artery. The diagnosis...

  13. Iatrogenic injury of an aberrant right posterior sectoral bile duct

    African Journals Online (AJOL)

    (Figs 1 and 2). A week later, an endoscopic retrograde cholangiopancreatography. (ERCP) examination was performed. This showed no filling of the right posterior sectoral ducts but normal opacification of the other ducts. (Figs 3a and b). These findings led to the diagnosis of an aberrant right posterior sectoral bile duct that ...

  14. Possibly Ill-behaved Posteriors in Econometric Models

    NARCIS (Netherlands)

    L.F. Hoogerheide (Lennart); H.K. van Dijk (Herman)

    2008-01-01

    textabstractHighly non-elliptical posterior distributions may occur in several econometric models, in particular, when the likelihood information is allowed to dominate and data information is weak. We explain the issue of highly non-elliptical posteriors in a model for the effect of education on

  15. MRI evaluation of the posterior meniscus root tear

    International Nuclear Information System (INIS)

    Zhang Jianjun; Zheng Zhuozhao; Li Xuan

    2010-01-01

    Objective: To determine the value of MRI for diagnosing the posterior meniscus root tear. Methods: MR examinations of 30 patients with tear of the posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. Of the 30 patients, 17 with posterior medial meniscus root tear (MMRT) and 13 with posterior lateral meniscus root tear (LMRT). The diagnostic sensitivity of' MRI for the posterior meniscus root tear was analyzed. Fisher's exact test was used to compare the detection rate of MRI for MMRT with that for LMRT. Results: All 17 cases with MMRT and 9 cases out of 13 with LMRT were correctly diagnosed by MRI and the diagnostic sensitivity of MRI for the posterior meniscus root tear was 86.7% (26/30). The main MR appearance of the posterior meniscus root tear was distortion of the meniscal root, with its low signal replaced by abnormal high signal. The detection rate of MRI for MMRT (17/17) was significantly greater than that for LMRT (9/13) (P=0.026). The prevalence of MMRT associated with meniscus extrusion (15/17) was significantly greater than that of LMRT (6/13) (P=0.020), but the prevalence of MMRT associated with anterior cruciate ligament (ACL) injury (5/17) was significantly lower than that of LMRT (11/13) (P=0.004). Conclusion: MRI is a relatively good method for detection of posterior meniscus root tears and associated injuries. (authors)

  16. Evaluation of the mechanical and physical properties of a posterior ...

    African Journals Online (AJOL)

    To evaluate the mechanical and physical properties of a micro-hybrid resin composite used in adult posterior restorations A micro-hybrid, light curing resin composite Unolux BCS Composite Restorative, (UnoDent, England) was used to restore 74 carious classes I and II cavities on posterior teeth of 62 adult patients.

  17. Partially ordered algebraic systems

    CERN Document Server

    Fuchs, Laszlo

    2011-01-01

    Originally published in an important series of books on pure and applied mathematics, this monograph by a distinguished mathematician explores a high-level area in algebra. It constitutes the first systematic summary of research concerning partially ordered groups, semigroups, rings, and fields. The self-contained treatment features numerous problems, complete proofs, a detailed bibliography, and indexes. It presumes some knowledge of abstract algebra, providing necessary background and references where appropriate. This inexpensive edition of a hard-to-find systematic survey will fill a gap i

  18. Infinite partial summations

    International Nuclear Information System (INIS)

    Sprung, D.W.L.

    1975-01-01

    This paper is a brief review of those aspects of the effective interaction problem that can be grouped under the heading of infinite partial summations of the perturbation series. After a brief mention of the classic examples of infinite summations, the author turns to the effective interaction problem for two extra core particles. Their direct interaction is summed to produce the G matrix, while their indirect interaction through the core is summed in a variety of ways under the heading of core polarization. (orig./WL) [de

  19. On universal partial words

    OpenAIRE

    Chen, Herman Z. Q.; Kitaev, Sergey; Mütze, Torsten; Sun, Brian Y.

    2016-01-01

    A universal word for a finite alphabet $A$ and some integer $n\\geq 1$ is a word over $A$ such that every word in $A^n$ appears exactly once as a subword (cyclically or linearly). It is well-known and easy to prove that universal words exist for any $A$ and $n$. In this work we initiate the systematic study of universal partial words. These are words that in addition to the letters from $A$ may contain an arbitrary number of occurrences of a special `joker' symbol $\\Diamond\

  20. Partial differential equations

    CERN Document Server

    Agranovich, M S

    2002-01-01

    Mark Vishik's Partial Differential Equations seminar held at Moscow State University was one of the world's leading seminars in PDEs for over 40 years. This book celebrates Vishik's eightieth birthday. It comprises new results and survey papers written by many renowned specialists who actively participated over the years in Vishik's seminars. Contributions include original developments and methods in PDEs and related fields, such as mathematical physics, tomography, and symplectic geometry. Papers discuss linear and nonlinear equations, particularly linear elliptic problems in angles and gener

  1. Partial differential equations

    CERN Document Server

    Levine, Harold

    1997-01-01

    The subject matter, partial differential equations (PDEs), has a long history (dating from the 18th century) and an active contemporary phase. An early phase (with a separate focus on taut string vibrations and heat flow through solid bodies) stimulated developments of great importance for mathematical analysis, such as a wider concept of functions and integration and the existence of trigonometric or Fourier series representations. The direct relevance of PDEs to all manner of mathematical, physical and technical problems continues. This book presents a reasonably broad introductory account of the subject, with due regard for analytical detail, applications and historical matters.

  2. Partial differential equations

    CERN Document Server

    Sloan, D; Süli, E

    2001-01-01

    /homepage/sac/cam/na2000/index.html7-Volume Set now available at special set price ! Over the second half of the 20th century the subject area loosely referred to as numerical analysis of partial differential equations (PDEs) has undergone unprecedented development. At its practical end, the vigorous growth and steady diversification of the field were stimulated by the demand for accurate and reliable tools for computational modelling in physical sciences and engineering, and by the rapid development of computer hardware and architecture. At the more theoretical end, the analytical insight in

  3. Elliptic partial differential equations

    CERN Document Server

    Han, Qing

    2011-01-01

    Elliptic Partial Differential Equations by Qing Han and FangHua Lin is one of the best textbooks I know. It is the perfect introduction to PDE. In 150 pages or so it covers an amazing amount of wonderful and extraordinary useful material. I have used it as a textbook at both graduate and undergraduate levels which is possible since it only requires very little background material yet it covers an enormous amount of material. In my opinion it is a must read for all interested in analysis and geometry, and for all of my own PhD students it is indeed just that. I cannot say enough good things abo

  4. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret...... of view as well as w.r.t. computational complexity. Finally, we present algorithms for both approaches for NMI which is comparable in speed to Sum of Squared Differences (SSD), and we illustrate the differences between PW and GPV on a number of registration examples....

  5. Decision salience signals in posterior cingulate cortex

    Directory of Open Access Journals (Sweden)

    Sarah eHeilbronner

    2011-04-01

    Full Text Available Despite its phylogenetic antiquity and clinical importance, the posterior cingulate cortex (CGp remains an enigmatic nexus of attention, memory, motivation, and decision making. Here we show that CGp neurons track decision salience—the degree to which an option differs from a standard—but not the subjective value of a decision. To do this, we recorded the spiking activity of CGp neurons in monkeys choosing between options varying in reward-related risk, delay to reward, and social outcomes, each of which varied in level of decision salience. Firing rates were higher when monkeys chose the risky option, consistent with their risk-seeking preferences, but were also higher when monkeys chose the delayed and social options, contradicting their preferences. Thus, across decision contexts, neuronal activity was uncorrelated with how much monkeys valued a given option, as inferred from choice. Instead, neuronal activity signaled the deviation of the chosen option from the standard, independently of how it differed. The observed decision salience signals suggest a role for CGp in the flexible allocation of neural resources to motivationally significant information, akin to the role of attention in selective processing of sensory inputs.

  6. Posterior Reversible Leukoencephalopathy Syndrome Associated with Pazopanib

    Directory of Open Access Journals (Sweden)

    Robert Foerster

    2013-04-01

    Full Text Available A 62-year-old female patient with metastatic renal cell carcinoma under third-line treatment with pazopanib for 8 weeks suddenly developed severe headaches, grand mal seizures and paresis of the left arm in combination with gait instability as well as nausea and vomiting during her vacation abroad. The emergency physician measured systolic blood pressure values over 300 mm Hg and suspected a stroke. The CT imaging without contrast agent in a local hospital did not show any pathologic findings despite bone metastases. The colleagues suspected cerebral metastases or meningeosis carcinomatosa and referred the patient to our department for further diagnostics and treatment planning. An MRI scan ruled out the suspected cerebral metastases or meningeosis carcinomatosa, but showed signs of reversible posterior leukoencephalopathy syndrome (RPLS in the form of band-like hyperintensities as a sign of cytotoxic edema in the gray and white matter of the left parietal lobe. The patient then reported that similar blood pressure values had been measured shortly after the start of a first-line therapy with sunitinib, so that we discontinued the current treatment with pazopanib. Within 6 days the neurologic symptoms vanished and the patient was discharged. An intermittent hypertension persisted. A follow-up MRI 3 weeks later showed an RPLS-typical cortical infarction in the affected area. RPLS should be considered as the actual reason for neurologic findings in hypertensive patients with known metastatic cancers under tyrosine kinase inhibitor therapy.

  7. Facilitating text reading in posterior cortical atrophy.

    Science.gov (United States)

    Yong, Keir X X; Rajdev, Kishan; Shakespeare, Timothy J; Leff, Alexander P; Crutch, Sebastian J

    2015-07-28

    We report (1) the quantitative investigation of text reading in posterior cortical atrophy (PCA), and (2) the effects of 2 novel software-based reading aids that result in dramatic improvements in the reading ability of patients with PCA. Reading performance, eye movements, and fixations were assessed in patients with PCA and typical Alzheimer disease and in healthy controls (experiment 1). Two reading aids (single- and double-word) were evaluated based on the notion that reducing the spatial and oculomotor demands of text reading might support reading in PCA (experiment 2). Mean reading accuracy in patients with PCA was significantly worse (57%) compared with both patients with typical Alzheimer disease (98%) and healthy controls (99%); spatial aspects of passages were the primary determinants of text reading ability in PCA. Both aids led to considerable gains in reading accuracy (PCA mean reading accuracy: single-word reading aid = 96%; individual patient improvement range: 6%-270%) and self-rated measures of reading. Data suggest a greater efficiency of fixations and eye movements under the single-word reading aid in patients with PCA. These findings demonstrate how neurologic characterization of a neurodegenerative syndrome (PCA) and detailed cognitive analysis of an important everyday skill (reading) can combine to yield aids capable of supporting important everyday functional abilities. This study provides Class III evidence that for patients with PCA, 2 software-based reading aids (single-word and double-word) improve reading accuracy. © 2015 American Academy of Neurology.

  8. Adult posterior urethral valve: a case report

    Science.gov (United States)

    Kilciler, Mete; Basal, Seref; Irkilata, Hasan Cem; Zor, Murat; Istanbulluoglu, Mustafa Okan; Dayanc, Murat

    2010-01-01

    Introduction: Posterior urethral valve (PUV) is a congenital obstructive defect of the male urethra with an incidence of 1/8,000 to 1/25,000 live births. PUV is the most common cause of lower urinary tract obstruction in neonates. The diagnosis of PUV is usually made early, and PUV cases have rarely been detected in adults. Case presentation: Here we report the case of a 35 years old man presented with obstructive urinary symptoms. In spite of bladder neck rejection uroflowmetry pointed out infravesical obstruction with max. flow rate 9 ml/s and average flow rate 6 ml/s in uroflowmetry. During cystoscopy mild bladder trabeculation and resected bladder neck were seen. While the cystoscope was taken off, PUV were obtained. Conclusion: Since PUV is a rare condition in adults and the diagnosis of PUVs is also difficult in these groups we must consider this situation during evaluation of adult patients with obstructive symptoms especially during cystourethroscopy. PMID:20379394

  9. Adult posterior urethral valve: a case report

    Directory of Open Access Journals (Sweden)

    Dayanc, Murat

    2010-03-01

    Full Text Available Introduction: Posterior urethral valve (PUV is a congenital obstructive defect of the male urethra with an incidence of 1/8,000 to 1/25,000 live births. PUV is the most common cause of lower urinary tract obstruction in neonates. The diagnosis of PUV is usually made early, and PUV cases have rarely been detected in adults. Case presentation: Here we report the case of a 35 years old man presented with obstructive urinary symptoms. In spite of bladder neck rejection uroflowmetry pointed out infravesical obstruction with max. flow rate 9 ml/s and average flow rate 6 ml/s in uroflowmetry. During cystoscopy mild bladder trabeculation and resected bladder neck were seen. While the cystoscope was taken off, PUV were obtained. Conclusion: Since PUV is a rare condition in adults and the diagnosis of PUVs is also difficult in these groups we must consider this situation during evaluation of adult patients with obstructive symptoms especially during cystourethroscopy.

  10. Magnocellular Neurons and Posterior Pituitary Function.

    Science.gov (United States)

    Brown, Colin H

    2016-09-15

    The posterior pituitary gland secretes oxytocin and vasopressin (the antidiuretic hormone) into the blood system. Oxytocin is required for normal delivery of the young and for delivery of milk to the young during lactation. Vasopressin increases water reabsorption in the kidney to maintain body fluid balance and causes vasoconstriction to increase blood pressure. Oxytocin and vasopressin secretion occurs from the axon terminals of magnocellular neurons whose cell bodies are principally found in the hypothalamic supraoptic nucleus and paraventricular nucleus. The physiological functions of oxytocin and vasopressin depend on their secretion, which is principally determined by the pattern of action potentials initiated at the cell bodies. Appropriate secretion of oxytocin and vasopressin to meet the challenges of changing physiological conditions relies mainly on integration of afferent information on reproductive, osmotic, and cardiovascular status with local regulation of magnocellular neurons by glia as well as intrinsic regulation by the magnocellular neurons themselves. This review focuses on the control of magnocellular neuron activity with a particular emphasis on their regulation by reproductive function, body fluid balance, and cardiovascular status. © 2016 American Physiological Society. Compr Physiol 6:1701-1741, 2016. Copyright © 2016 John Wiley & Sons, Inc.

  11. Cognitive Control Signals in Posterior Cingulate Cortex

    Directory of Open Access Journals (Sweden)

    Benjamin eHayden

    2010-12-01

    Full Text Available Efficiently shifting between tasks is a central function of cognitive control. The role of the default network—a constellation of areas with high baseline activity that declines during task performance—in cognitive control remains poorly understood. We hypothesized that task switching demands cognitive control to shift the balance of processing towards the external world, and therefore predicted that switching between the two tasks would require suppression of activity of neurons within the CGp. To test this idea, we recorded the activity of single neurons in posterior cingulate cortex (CGp, a central node in the default network, in monkeys performing two interleaved tasks. As predicted, we found that basal levels of neuronal activity were reduced following a switch from one task to another and gradually returned to pre-switch baseline on subsequent trials. We failed to observe these effects in lateral intraparietal cortex (LIP, part of the dorsal fronto-parietal cortical attention network directly connected to CGp. These findings indicate that suppression of neuronal activity in CGp facilitates cognitive control, and suggest that activity in the default network reflects processes that directly compete with control processes elsewhere in the brain..

  12. Facilitating text reading in posterior cortical atrophy

    Science.gov (United States)

    Rajdev, Kishan; Shakespeare, Timothy J.; Leff, Alexander P.; Crutch, Sebastian J.

    2015-01-01

    Objective: We report (1) the quantitative investigation of text reading in posterior cortical atrophy (PCA), and (2) the effects of 2 novel software-based reading aids that result in dramatic improvements in the reading ability of patients with PCA. Methods: Reading performance, eye movements, and fixations were assessed in patients with PCA and typical Alzheimer disease and in healthy controls (experiment 1). Two reading aids (single- and double-word) were evaluated based on the notion that reducing the spatial and oculomotor demands of text reading might support reading in PCA (experiment 2). Results: Mean reading accuracy in patients with PCA was significantly worse (57%) compared with both patients with typical Alzheimer disease (98%) and healthy controls (99%); spatial aspects of passages were the primary determinants of text reading ability in PCA. Both aids led to considerable gains in reading accuracy (PCA mean reading accuracy: single-word reading aid = 96%; individual patient improvement range: 6%–270%) and self-rated measures of reading. Data suggest a greater efficiency of fixations and eye movements under the single-word reading aid in patients with PCA. Conclusions: These findings demonstrate how neurologic characterization of a neurodegenerative syndrome (PCA) and detailed cognitive analysis of an important everyday skill (reading) can combine to yield aids capable of supporting important everyday functional abilities. Classification of evidence: This study provides Class III evidence that for patients with PCA, 2 software-based reading aids (single-word and double-word) improve reading accuracy. PMID:26138948

  13. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  14. Posterior distributions for likelihood ratios in forensic science.

    Science.gov (United States)

    van den Hout, Ardo; Alberink, Ivo

    2016-09-01

    Evaluation of evidence in forensic science is discussed using posterior distributions for likelihood ratios. Instead of eliminating the uncertainty by integrating (Bayes factor) or by conditioning on parameter values, uncertainty in the likelihood ratio is retained by parameter uncertainty derived from posterior distributions. A posterior distribution for a likelihood ratio can be summarised by the median and credible intervals. Using the posterior mean of the distribution is not recommended. An analysis of forensic data for body height estimation is undertaken. The posterior likelihood approach has been criticised both theoretically and with respect to applicability. This paper addresses the latter and illustrates an interesting application area. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Posterior Probability Matching and Human Perceptual Decision Making.

    Directory of Open Access Journals (Sweden)

    Richard F Murray

    2015-06-01

    Full Text Available Probability matching is a classic theory of decision making that was first developed in models of cognition. Posterior probability matching, a variant in which observers match their response probabilities to the posterior probability of each response being correct, is being used increasingly often in models of perception. However, little is known about whether posterior probability matching is consistent with the vast literature on vision and hearing that has developed within signal detection theory. Here we test posterior probability matching models using two tools from detection theory. First, we examine the models' performance in a two-pass experiment, where each block of trials is presented twice, and we measure the proportion of times that the model gives the same response twice to repeated stimuli. We show that at low performance levels, posterior probability matching models give highly inconsistent responses across repeated presentations of identical trials. We find that practised human observers are more consistent across repeated trials than these models predict, and we find some evidence that less practised observers more consistent as well. Second, we compare the performance of posterior probability matching models on a discrimination task to the performance of a theoretical ideal observer that achieves the best possible performance. We find that posterior probability matching is very inefficient at low-to-moderate performance levels, and that human observers can be more efficient than is ever possible according to posterior probability matching models. These findings support classic signal detection models, and rule out a broad class of posterior probability matching models for expert performance on perceptual tasks that range in complexity from contrast discrimination to symmetry detection. However, our findings leave open the possibility that inexperienced observers may show posterior probability matching behaviour, and our methods

  16. Unilateral removable partial dentures.

    Science.gov (United States)

    Goodall, W A; Greer, A C; Martin, N

    2017-01-27

    Removable partial dentures (RPDs) are widely used to replace missing teeth in order to restore both function and aesthetics for the partially dentate patient. Conventional RPD design is frequently bilateral and consists of a major connector that bridges both sides of the arch. Some patients cannot and will not tolerate such an extensive appliance. For these patients, bridgework may not be a predictable option and it is not always possible to provide implant-retained restorations. This article presents unilateral RPDs as a potential treatment modality for such patients and explores indications and contraindications for their use, including factors relating to patient history, clinical presentation and patient wishes. Through case examples, design, material and fabrication considerations will be discussed. While their use is not widespread, there are a number of patients who benefit from the provision of unilateral RPDs. They are a useful treatment to have in the clinician's armamentarium, but a highly-skilled dental team and a specific patient presentation is required in order for them to be a reasonable and predictable prosthetic option.

  17. Magnetic Fixed Points and Emergent Supersymmetry

    DEFF Research Database (Denmark)

    Antipin, Oleg; Mojaza, Matin; Pica, Claudio

    2013-01-01

    We establish in perturbation theory the existence of fixed points along the renormalization group flow for QCD with an adjoint Weyl fermion and scalar matter reminiscent of magnetic duals of QCD [1-3]. We classify the fixed points by analyzing their basin of attraction. We discover that among...

  18. Fixed Wireless may be a temporary answer

    Indian Academy of Sciences (India)

    Possible to enhance throughput by 4 with respect to Mobile Wireless. And get 8 to 10 bps / Hz / cell; Examples: BB corDECT: today provides 256/512kbps to each connection in fixed environment. Ideal for small town / rural Broadband. Fixed 802.16d/e does the same in but at much higher price-points.

  19. Metallic and antiferromagnetic fixed points from gravity

    Science.gov (United States)

    Paul, Chandrima

    2018-06-01

    We consider SU(2) × U(1) gauge theory coupled to matter field in adjoints and study RG group flow. We constructed Callan-Symanzik equation and subsequent β functions and study the fixed points. We find there are two fixed points, showing metallic and antiferromagnetic behavior. We have shown that metallic phase develops an instability if certain parametric conditions are satisfied.

  20. Gaining Insight into an Organization's Fixed Assets.

    Science.gov (United States)

    Hardy, Elisabet

    2003-01-01

    Discusses issues related to school district implementation of June 2001 Government Accounting Standards Board (GASB) Statement 34 designed to change how schools report fixed assets. Includes planning for GASB implementation, conducting fixed-asset inventories, and making time for GASB reporting. (PKP)

  1. 78 FR 20705 - Fixed Income Roundtable

    Science.gov (United States)

    2013-04-05

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-69275; File No. 4-660] Fixed Income Roundtable... of fixed income markets. The roundtable will focus on the municipal securities, corporate bonds, and asset-backed securities markets. The roundtable discussion will be held in the multi-purpose room of the...

  2. Gauge fixing problem in the conformal QED

    International Nuclear Information System (INIS)

    Ichinose, Shoichi

    1986-01-01

    The gauge fixing problem in the conformal (spinor and scalar) QED is examined. For the analysis, we generalize Dirac's manifestly conformal-covariant formalism. It is shown that the (vector and matter) fields must obey a certain mixed (conformal and gauge) type of transformation law in order to fix the local gauge symmetry preserving the conformal invariance in the Lagrangian. (orig.)

  3. Fixed export cost heterogeneity, trade and welfare

    DEFF Research Database (Denmark)

    Jørgensen, Jan Guldager; Schröder, Philipp J.H.

    2008-01-01

    -country intra-industry trade model where firms are of two different marginal costs types and where fixed export costs are heterogeneous across firms. This model traces many of the stylized facts of international trade. However, we find that with heterogeneous fixed export costs there exists a positive bilateral...

  4. Impact of fixed-mobile convergence

    DEFF Research Database (Denmark)

    Pachnicke, Stephan; Andrus, Bogdan-Mihai; Autenrieth, Achim

    2016-01-01

    Fixed-Mobile Convergence (FMC) is a very trendy concept as it promises integration of the previously separated fixed access network and the mobile network. From this novel approach telecommunication operators expect significant cost savings and performance improvements. FMC can be separated...

  5. Prospective clinical study of prosthetic treatment outcome of implantretained-removable-partial-denture during 5 year-follow-ups

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-11-01

    Full Text Available Background IRRPD offers patients the ability to upgrade their treatment planning to implant-supported-overdentures (ISOs or implant-supported-fixed-prostheses (ISFPs through insertion of more implants in the future after the loss of the remaining natural teeth. Aims The purpose of this prospective-clinical-study was to evaluate the success rate and treatment outcome of IRRPD for 15 patients, during at least 5-year-follow-ups after prosthetic rehabilitation with respect to implant mobility, peri-implant-marginal-bone-levels, and prosthetic complications. Methods 15 successive patients were attended the Department of Implantology and Prosthodontics in TUMS, and received Implant-Retained-Removable-Partial-Dentures (IRRPDs. Two standard-size-dental-implants (Implantium/Dentium system, internal hexagon, Seoul, South Korea were placed in distal-extension-areas for each patient. After the osseointegration period, all patients received IRRPDs using two Ball attachments. All the participated patients were followed-up at least for 5 years, and the survival rate of 30 implants was evaluated. The patients’ satisfaction of function, phonetics, and aesthetics was assessed by means of questionnaire. Results None of the studied patients reported any prosthetic complications during the follow-up-periods such as attachment loosening, metal housing loosening, or denture fracture. No implants failure was recorded, so that the cumulative-implant-survival rate was 100 per cent. The mean marginal-bone-resorption (MBR around the two implants was 0.9mm with a range of 0.5–1.4mm. Teeth aesthetics was judged as excellent or very good by 86.7 per cent of the patients, while phonetics and mastication were considered excellent or very good by 66.7 per cent and 73.3 per cent of the patients, respectively. Conclusion 15 patients received 30 implants for the fabrication of IRRPDs in the posterior-edentulous-sites. The IRRPDs were delivered to the patients by the same

  6. Convergence criteria for systems of nonlinear elliptic partial differential equations

    International Nuclear Information System (INIS)

    Sharma, R.K.

    1986-01-01

    This thesis deals with convergence criteria for a special system of nonlinear elliptic partial differential equations. A fixed-point algorithm is used, which iteratively solves one linearized elliptic partial differential equation at a time. Conditions are established that help foresee the convergence of the algorithm. Under reasonable hypotheses it is proved that the algorithm converges for such nonlinear elliptic systems. Extensive experimental results are reported and they show the algorithm converges in a wide variety of cases and the convergence is well correlated with the theoretical conditions introduced in this thesis

  7. Global gauge fixing in lattice gauge theories

    Energy Technology Data Exchange (ETDEWEB)

    Fachin, S.; Parrinello, C. (Physics Department, New York University, 4 Washington Place, New York, New York (USA))

    1991-10-15

    We propose a covariant, nonperturbative gauge-fixing procedure for lattice gauge theories that avoids the problem of Gribov copies. This is closely related to a recent proposal for a gauge fixing in the continuum that we review. The lattice gauge-fixed model allows both analytical and numerical investigations: on the analytical side, explicit nonperturbative calculations of gauge-dependent quantities can be easily performed in the framework of a generalized strong-coupling expansion, while on the numerical side a stochastic gauge-fixing algorithm is very naturally associated with the scheme. In both applications one can study the gauge dependence of the results, since the model actually provides a smooth'' family of gauge-fixing conditions.

  8. Algorithms for solving common fixed point problems

    CERN Document Server

    Zaslavski, Alexander J

    2018-01-01

    This book details approximate solutions to common fixed point problems and convex feasibility problems in the presence of perturbations. Convex feasibility problems search for a common point of a finite collection of subsets in a Hilbert space; common fixed point problems pursue a common fixed point of a finite collection of self-mappings in a Hilbert space. A variety of algorithms are considered in this book for solving both types of problems, the study of which has fueled a rapidly growing area of research. This monograph is timely and highlights the numerous applications to engineering, computed tomography, and radiation therapy planning. Totaling eight chapters, this book begins with an introduction to foundational material and moves on to examine iterative methods in metric spaces. The dynamic string-averaging methods for common fixed point problems in normed space are analyzed in Chapter 3. Dynamic string methods, for common fixed point problems in a metric space are introduced and discussed in Chapter ...

  9. The price of fixed income market volatility

    CERN Document Server

    Mele, Antonio

    2015-01-01

    Fixed income volatility and equity volatility evolve heterogeneously over time, co-moving disproportionately during periods of global imbalances and each reacting to events of different nature. While the methodology for options-based "model-free" pricing of equity volatility has been known for some time, little is known about analogous methodologies for pricing various fixed income volatilities. This book fills this gap and provides a unified evaluation framework of fixed income volatility while dealing with disparate markets such as interest-rate swaps, government bonds, time-deposits and credit. It develops model-free, forward looking indexes of fixed-income volatility that match different quoting conventions across various markets, and uncovers subtle yet important pitfalls arising from naïve superimpositions of the standard equity volatility methodology when pricing various fixed income volatilities. The ultimate goal of the authors´ efforts is to make interest rate volatility standardization a valuable...

  10. No difference in gait between posterior cruciate retention and the posterior stabilized design after total knee arthroplasty

    NARCIS (Netherlands)

    van den Boom, Lennard G. H.; Halbertsma, Jan P. K.; van Raaij, Jos J. A. M.; Brouwer, Reinoud W.; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge

    2014-01-01

    In the present study, knee joint kinematics (e.g. knee flexion/extension) and kinetics (e.g. knee flexion moments) are assessed after total knee arthroplasty (TKA) between patients implanted with either a unilateral posterior stabilized (PS) and a posterior cruciate-retaining (PCR) design. It was

  11. Systematic review and meta-analysis of laparoscopic Nissen (posterior total) versus Toupet (posterior partial) fundoplication for gastro-oesophageal reflux disease

    NARCIS (Netherlands)

    Broeders, J. A. J. L.; Mauritz, F. A.; Ahmed Ali, U.; Draaisma, W. A.; Ruurda, J. P.; Gooszen, H. G.; Smout, A. J. P. M.; Broeders, I. A. M. J.; Hazebroek, E. J.

    2010-01-01

    BACKGROUND: Laparoscopic Nissen fundoplication (LNF) is currently considered the surgical approach of choice for gastro-oesophageal reflux disease (GORD). Laparoscopic Toupet fundoplication (LTF) has been said to reduce troublesome dysphagia and gas-related symptoms. A systematic review and

  12. Tutorial on Online Partial Evaluation

    Directory of Open Access Journals (Sweden)

    William R. Cook

    2011-09-01

    Full Text Available This paper is a short tutorial introduction to online partial evaluation. We show how to write a simple online partial evaluator for a simple, pure, first-order, functional programming language. In particular, we show that the partial evaluator can be derived as a variation on a compositionally defined interpreter. We demonstrate the use of the resulting partial evaluator for program optimization in the context of model-driven development.

  13. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML...

  14. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML of ...

  15. Ultrasonographic findings of posterior interosseous nerve syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Dong; Ha, Doo Hoe; Lee, Sang Min [Dept. of Radiology, CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2017-10-15

    The purpose of this study was to evaluate the ultrasonographic findings associated with posterior interosseous nerve (PIN) syndrome. Approval from the Institutional Review Board was obtained. A retrospective review of 908 patients' sonographic images of the upper extremity from January 2001 to October 2010 revealed 10 patients suspicious for a PIN abnormality (7 male and 3 female patients; mean age of 51.8±13.1 years; age range, 32 to 79 years). The ultrasonographic findings of PIN syndrome, including changes in the PIN and adjacent secondary changes, were evaluated. The anteroposterior diameter of the pathologic PIN was measured in eight patients and the anteroposterior diameter of the contralateral asymptomatic PIN was measured in six patients, all at the level immediately proximal to the proximal supinator border. The size of the pathologic nerves and contralateral asymptomatic nerves was compared using the Mann-Whitney U test. Swelling of the PIN proximal to the supinator canal by compression at the arcade of Fröhse was observed in four cases. Swelling of the PIN distal to the supinator canal was observed in one case. Loss of the perineural fat plane in the supinator canal was observed in one case. Four soft tissue masses were noted. Secondary denervation atrophy of the supinator and extensor muscles was observed in two cases. The mean anteroposterior diameter of the pathologic nerves (n=8, 1.79±0.43 mm) was significantly larger than that of the contralateral asymptomatic nerves (n=6, 1.02±0.22 mm) (P=0.003). Ultrasonography provides high-resolution images of the PIN and helps to diagnose PIN syndrome through visualization of its various causes and adjacent secondary changes.

  16. Anatomical Variability of the Posterior Communicating Artery.

    Science.gov (United States)

    Gunnal, Sandhya Arvind; Farooqui, Mujibuddin S; Wabale, Rajendra N

    2018-01-01

    Although posterior communicating artery (PCoA) is a smaller branch of the internal carotid artery, it gives the main contribution in the formation of circle of Willis (CW) by communicating with the internal carotid arterial system and the vertebro-basilar arterial system. The size of PCoA varies frequently. The present work aims to study the PCoA regarding its morphology, morphometry, and symmetry. This study was conducted on 170 human cadaveric brains. Brains were dissected carefully and delicately to expose all components of CW, especially PCoA. Morphological variations of PCoA were noted along with its morphometry and symmetry. Morphological variations of PCoA were aplasia (3.52%), hypoplasia (25.29%), fenestration (0.58%), and persistent fetal pattern (16.47%). In the present study, we found the five different types of terminations of PCoA. Type I termination was the most common type, seen in 92.94% of cases, Type II termination was seen in 1.17%, Type III and Type IV terminations both were seen in 0.58%, and Type V was seen in 1.17%. The mean length of PCoA was 15.9 mm and 15.3 mm on the right and left sides, respectively. The mean diameter of PCoA was 2.1 mm and 1.9 mm on the right and left sides, respectively. Symmetry of PCoA was seen in 65.29% and asymmetric PCoA was seen in 34.70% of cases. The present study provides the complete description of PCoA regarding its morphology, symmetry, and morphometry. Awareness of these anatomical variations is important in neurovascular procedures.

  17. Consensus classification of posterior cortical atrophy.

    Science.gov (United States)

    Crutch, Sebastian J; Schott, Jonathan M; Rabinovici, Gil D; Murray, Melissa; Snowden, Julie S; van der Flier, Wiesje M; Dickerson, Bradford C; Vandenberghe, Rik; Ahmed, Samrah; Bak, Thomas H; Boeve, Bradley F; Butler, Christopher; Cappa, Stefano F; Ceccaldi, Mathieu; de Souza, Leonardo Cruz; Dubois, Bruno; Felician, Olivier; Galasko, Douglas; Graff-Radford, Jonathan; Graff-Radford, Neill R; Hof, Patrick R; Krolak-Salmon, Pierre; Lehmann, Manja; Magnin, Eloi; Mendez, Mario F; Nestor, Peter J; Onyike, Chiadi U; Pelak, Victoria S; Pijnenburg, Yolande; Primativo, Silvia; Rossor, Martin N; Ryan, Natalie S; Scheltens, Philip; Shakespeare, Timothy J; Suárez González, Aida; Tang-Wai, David F; Yong, Keir X X; Carrillo, Maria; Fox, Nick C

    2017-08-01

    A classification framework for posterior cortical atrophy (PCA) is proposed to improve the uniformity of definition of the syndrome in a variety of research settings. Consensus statements about PCA were developed through a detailed literature review, the formation of an international multidisciplinary working party which convened on four occasions, and a Web-based quantitative survey regarding symptom frequency and the conceptualization of PCA. A three-level classification framework for PCA is described comprising both syndrome- and disease-level descriptions. Classification level 1 (PCA) defines the core clinical, cognitive, and neuroimaging features and exclusion criteria of the clinico-radiological syndrome. Classification level 2 (PCA-pure, PCA-plus) establishes whether, in addition to the core PCA syndrome, the core features of any other neurodegenerative syndromes are present. Classification level 3 (PCA attributable to AD [PCA-AD], Lewy body disease [PCA-LBD], corticobasal degeneration [PCA-CBD], prion disease [PCA-prion]) provides a more formal determination of the underlying cause of the PCA syndrome, based on available pathophysiological biomarker evidence. The issue of additional syndrome-level descriptors is discussed in relation to the challenges of defining stages of syndrome severity and characterizing phenotypic heterogeneity within the PCA spectrum. There was strong agreement regarding the definition of the core clinico-radiological syndrome, meaning that the current consensus statement should be regarded as a refinement, development, and extension of previous single-center PCA criteria rather than any wholesale alteration or redescription of the syndrome. The framework and terminology may facilitate the interpretation of research data across studies, be applicable across a broad range of research scenarios (e.g., behavioral interventions, pharmacological trials), and provide a foundation for future collaborative work. Copyright © 2017 The Authors

  18. CT findings of posterior fossa venous angiomas

    International Nuclear Information System (INIS)

    Satoh, Toru; Kinugasa, Kazushi; Nishimoto, Akira; Nishimoto, Ken.

    1986-01-01

    Three cases of posterior fossa venous angiomas were reported, with some comments on the CT findings. Case 1: A 53-year-old woman was admitted for the further examination of a viral meningitis which had appeared three months before. Neurological examination revealed no abnormality. Vertebral angiography, however, demonstrated numerous fine medullary veins, with an enlarged intraparenchymal draining vein, in the right cerebellum; they drained into the petrosal vein, which was characteristic of venous angioma. On the plain CT, part of the draining vein was identified as a slightly high-density node. A curvilinear draining vein was demonstrated by the enhanced CT. Case 2: A 29-year-old man was admitted complaining of headache, vomiting, and atxia. Neurological examination disclosed truncal ataxia. The enhanced CT demonstrated two distinct nodules on the anterior border of the hematoma in the deep median cerebellum, probably corresponding to the draining veins. On the angiogram, a venous angioma was found in the bilateral cerebellum; it drained into the precentral cerebellar veins and ultimately joined the straight sinus via the precentro-vermo-rectal vein. Case 3: A 4-year-old boy was admitted suffering from headache, vomiting, and ataxia. Neurological examination disclosed a co-ordination disturbance of the left side. The enhanced CT demonstrated a curvilinear structure inside the hematoma. Angiography showed a venous angioma in the left cerebellum which drained into the petrosal vein. Computerized angiotomography delineated the characteristic venous structure on the angiogram as many fine, high-density lines (medullary veins) converging to a large intraparenchymal linear structure (central medullary vein) and then to a superficial cortical vein. In all cases, large intraparenchymal draining veins were identified by the conventional CT. (J.P.N.)

  19. An evaluation of Microleakage of Posterior Composites

    Directory of Open Access Journals (Sweden)

    Mohammadi N

    1999-12-01

    Full Text Available Polymerization contraction may produce defects in the composite - tooth bond. This may lead to bond failure and microleakage. The aim of this study was to reduce microleakage of posterior composites using different methods. 45 molar and premolars extracted teeth were choosen. The cavities were randomly assigned into 5 groups of 9. Box-shaped cavities were prepared on each side of proximal surfaces and restored by five different methods. Group 1 was filled by a light-cured composite and dentin bonding agents (DBAs with light curing from the occlusal area. Group 2 was filled by a light-cured {LC} composite and DBA, in addition the angle between the light source and occlusal area was 45 degree. After conditioning of teeth in-group 3, LC glass ionomer was placed on the gingival floor and then filled by a light-cured composite and DBA. In group 4, after conditioning, the teeth were lined by a LC glass ionomer and then self-cured composite was placed on gingival floor. This group was filled with LC composite. In Group 5 DBA was used followed by placing a self-curing composite on gingival floor and filled by LC composite. The teeth were subjected to 500 thermocycling (5°C and 55°C with dowel time 30 s and stored in 0.5% basic fushin for 24 hours. Dye penetration was evaluated by light microscope. The results were tested by Kruskat-Wallis one-way analysis of variance by rank. The comparison between treatment groups showed highly significant difference {P<0.0001. No significant difference was found between groups 3 versus 4 and groups 1,2,5 versus 3,4. Group 3 showed the least microleakage score. Therefore least microleakage was obtained by the group which used L C glass ionomer and DBA followed by filling a composite.

  20. Anterior Commissure-posterior commissure revisited

    International Nuclear Information System (INIS)

    Choi, Sang Han; Chi, Je Geun; Kim, Young Bo; Cho, Zang Hee

    2013-01-01

    The anterior commissure (AC) and posterior commissure (PC) are the two distinct anatomic structures in the brain which are difficult to observe in detail with conventional MRI, such as a 1.5T MRI system. However, recent advances in ultra-high resolution MRI have enabled us to examine the AC and PC directly. The objective of the present study is to standardize the shape and size of the AC and PC using a 7.0T MRI and to propose a new brain reference line. Thirty-four, 21 males and 13 females, healthy volunteers were enrolled in this study. After determining the center of each AC and PC, we defined the connection of these centers as the central intercommissural line (CIL). We compared the known extra- and intra-cerebral reference lines with the CIL to determine the difference in the angles. Additionally, we obtained horizontal line from flat ground line of look front human. The difference in angle of the CIL and the tangential intercommissural line (TIL) from the horizontal line was 8.7 ± 5.1 (11 ± 4.8) and 17.4 ± 5.2 (19.8 ± 4.8) degrees in males and females, respectively. The difference in angle between the CIL and canthomeatal line was 10.1 in both male and female, and there was no difference between both sexes. Likewise, there was no significant difference in angle between the CIL and TIL between both sexes (8.3 +/- 1.1 in male and 8.8 +/- 0.7 in female). In this study, we have used 7.0T MRI to define the AC and PC quantitatively and in a more robust manner. We have showed that the CIL is a reproducible reference line and serves as a standard for the axial images of the human brain.

  1. [Efficacies of arthroscopic debridement and olecranon fossa plasty in the treatment of osteoarthritis and posterior elbow impingement].

    Science.gov (United States)

    Liu, Yu-jie; Wang, Jun-liang; Li, Hai-feng; Qi, Wei; Wang, Ning

    2012-07-17

    To evaluate the efficacies of arthroscopic debridement and removal of osteophyma for olecroanon and olecranon fossa plasty for posterior impingement of elbow joint. Between 1999 and 2008, a total of 21 cases were diagnosed with osteoarthritis and posterior elbow impingement. There were 15 males and 6 females. And there were 16 right and 15 left cases. They included volleyball players (n = 7), tennis players (n = 7), golf enthusiasts (n = 4) and fencers (n = 3). The average duration of onset-operation was 3.5 years (range: 2.5 - 8). Arthroscopic exploration revealed synovial hyperplasia hypertrophy, cartilage degeneration and olecranon fossa hyperplasia with deformed olecranon fossa. Debridement and plasty were performed. Loose bodies were removed from elbow joint in 6 patients. Partial resection of posterior olecranon tip was performed and osteophytes or fibrous tissue removed in this area. Dynamic observation showed no posterior elbow impingement. Postoperative follow-up was conducted in 19 cases and 2 cases became lost to follow-up. The average follow-up period was 25.3 months (range: 18 - 42). All patients were evaluated preoperatively and postoperatively with the Hospital for Special Surgery Elbow Assessment Scale. The outcomes were excellent (n = 12), good (n = 7) and fair (n = 2). Postoperative patients elbow swelling and pain relieve, sports and life function returns to normal, elbow flexion and rotating mobility obviously improved. With the elbow radiological films to measure the range of motion, the average range of motion was 90.5° preoperatively and improved to 130° postoperatively. There was significant improvement in all cases. Posterior elbow impingement is caused by hyperextension trauma and elbow overuse during specific sporting activities. Arthroscopic debridement and olecroanon or olecranon fossa plasty demonstrates excellent results for posterior impingement of elbow joint.

  2. METHOD FOR PRODUCING ISOTOPIC METHANES AND PARTIALLY HALOGENATED DERIVATIVES THEROF

    Science.gov (United States)

    Frazer, J.W.

    1959-08-18

    A method is given for producing isotopic methanes and/ or partially halogenated derivatives. Lithium hydride, deuteride, or tritide is reacted with a halogenated methane or with a halogenated methane in combination with free halogen. The process is conveniently carried out by passing a halogenated methane preferably at low pressures or in an admixture with an inert gas through a fixed bed of finely divided lithium hydride heated initially to temperatures of 100 to 200 deg C depending upon the halogenated methane used.

  3. Applied partial differential equations

    CERN Document Server

    Logan, J David

    2004-01-01

    This primer on elementary partial differential equations presents the standard material usually covered in a one-semester, undergraduate course on boundary value problems and PDEs. What makes this book unique is that it is a brief treatment, yet it covers all the major ideas: the wave equation, the diffusion equation, the Laplace equation, and the advection equation on bounded and unbounded domains. Methods include eigenfunction expansions, integral transforms, and characteristics. Mathematical ideas are motivated from physical problems, and the exposition is presented in a concise style accessible to science and engineering students; emphasis is on motivation, concepts, methods, and interpretation, rather than formal theory. This second edition contains new and additional exercises, and it includes a new chapter on the applications of PDEs to biology: age structured models, pattern formation; epidemic wave fronts, and advection-diffusion processes. The student who reads through this book and solves many of t...

  4. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  5. Fundamental partial compositeness

    CERN Document Server

    Sannino, Francesco

    2016-11-07

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough 'square root'. Furthermore, right-handed SM fermions have an SU(2)$_R$-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  6. Fundamental partial compositeness

    International Nuclear Information System (INIS)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea; Vigiani, Elena

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Under certain assumptions on the dynamics of the scalars, successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough ‘square root’. Furthermore, right-handed SM fermions have an SU(2)_R-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  7. Partial oxidation process

    International Nuclear Information System (INIS)

    Najjar, M.S.

    1987-01-01

    A process is described for the production of gaseous mixtures comprising H/sub 2/+CO by the partial oxidation of a fuel feedstock comprising a heavy liquid hydrocarbonaceous fuel having a nickel, iron, and vanadium-containing ash or petroleum coke having a nickel, iron, and vanadium-containing ash, or mixtures thereof. The feedstock includes a minimum of 0.5 wt. % of sulfur and the ash includes a minimum of 5.0 wt. % vanadium, a minimum of 0.5 ppm nickel, and a minimum of 0.5 ppm iron. The process comprises: (1) mixing together a copper-containing additive with the fuel feedstock; wherein the weight ratio of copper-containing additive to ash in the fuel feedstock is in the range of about 1.0-10.0, and there is at least 10 parts by weight of copper for each part by weight of vanadium; (2) reacting the mixture from (1) at a temperature in the range of 2200 0 F to 2900 0 F and a pressure in the range of about 5 to 250 atmospheres in a free-flow refactory lined partial oxidation reaction zone with a free-oxygen containing gas in the presence of a temperature moderator and in a reducing atmosphere to produce a hot raw effluent gas stream comprising H/sub 2/+CO and entrained molten slag; and where in the reaction zone and the copper-containing additive combines with at least a portion of the nickel and iron constituents and sulfur found in the feedstock to produce a liquid phase washing agent that collects and transports at least a portion of the vanadium-containing oxide laths and spinels and other ash components and refractory out of the reaction zone; and (3) separating nongaseous materials from the hot raw effluent gas stream

  8. CT findings of traumatic posterior hip dislocation after reduction

    International Nuclear Information System (INIS)

    Moon, Sung Kyoung; Park, Ji Seon; Ryu, Kyung Nam; Jin, Wook; Jin Wook

    2008-01-01

    To evaluate the CT images of reduced hips after posterior hip dislocation and to propose specific diagnostic criteria based on the CT results. We retrospectively reviewed the CT findings on 18 reduced hips from 17 patients with radiographs and clinical histories of traumatic posterior hip dislocations by evaluating 18 corresponding CT scans for joint space asymmetry, intra-articular abnormalities (intra-articular fat obliteration, loose bodies, and joint effusion), changes in posterior soft tissue (capsule, muscles, and adjacent fat), the presence, and location of fractures (acetabulum and femoral head). All 18 hips (100%) showed posterior soft tissue changes. In total, 17 hips (94.4%) had intra-articular abnormalities and 15 hips (83.3%) had joint space asymmetries. In addition, 17 hips (94.4%) had fractures involving the acetabula (15 cases, 88.2%) the femoral head (13 cases, 76.5%), or on both sides (11 cases, 64.7%). The most frequent fracture location was in he posterior wall (13/15, 86.7%) of the acetabulum and in the anterior aspect (10/13, 76.9%) of the femoral head. Patients with a prior history of posterior hip dislocation showed specific CT findings after reduction, suggesting the possibility of previous posterior hip dislocations in patients

  9. Combination of natural teeth and osseointegrated implants as prosthesis abutments in a posterior cantilever bridge

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2008-06-01

    Full Text Available Dental implants have been used for several decades. Patients of all ages have chosen dental implants to replace a single tooth or several teeth or to support partial or full dentures. This paper reports two cases of patients treated with dental implant as alternative to replace the missing teeth and connected with natural tooth as abutments in a fixed restoration with distal cantilever bridge. The underlining reasons that we decided to make such kind fixed prostheses are because of clinically imposible to put the implant on certain area and the patients asked for prostheses as optimum as possible, so the mastication function could return to the homeostasis condition. The benefit of these treatments are that prostheses could be made as optimum as possible with a more economic price, so the patients feel quite satisfied. The result shows that a few years after the treatments finished there is no any disadvantageous effect of connecting teeth to implants as abutments in fixed partial dentures and there is no sign of a harmful effect to the opposing teeth either.

  10. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  11. Combined application of ultrasound and of radiodiagnostic methods in diagnosis of posterior dislocation of the lens

    International Nuclear Information System (INIS)

    Preisova, J.; Vlkova, E.; Svacinova, J.; Papouskova, D.

    1990-01-01

    A case study is presented of a patient with opaque media of the left eye for seclusion and occlusion of the pupil. The cause of the unilateral chronic uveitis was visualized using ultrasound in A mode. It was found that the calcified lens was dislocated into the vitreous body and fixed to the posterior wall of the eye. The finding was confirmed by a negative X-ray picture and positive CT finding of a small foreign body with high density. The dislocation of the lens occurred after a blow on the left eye during boxing 15 years before the patient sought medical assistance for pain in the practically blind eyeball. (author). 4 figs., 9 refs

  12. Alterations in right posterior hippocampus in early blind individuals

    DEFF Research Database (Denmark)

    Chebat, Daniel-Robert; Chen, Jan-Kai; Schneider, Fabien

    2007-01-01

    This study compares hippocampal volumes of early blind and sex/age-matched sighted controls through volumetric and localization analyses. Early blind individuals showed a significantly smaller right posterior hippocampus compared with controls. No differences in total hippocampal volumes were fou...... of the posterior hippocampus in early blind individuals suggests the implication of this region in visual spatial memory. Udgivelsesdato: 2007-Mar-5......This study compares hippocampal volumes of early blind and sex/age-matched sighted controls through volumetric and localization analyses. Early blind individuals showed a significantly smaller right posterior hippocampus compared with controls. No differences in total hippocampal volumes were found...

  13. Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components.

    Science.gov (United States)

    Jiao, T; Chang, T; Caputo, A A

    2009-03-01

    To photoelastically examine load transfer by unilateral distal extension removable partial dentures with supporting and retentive components made of the lower stiffness polyacetal resins. A mandibular photoelastic model, with edentulous space distal to the right second premolar and missing the left first molar, was constructed to determine the load transmission characteristics of a unilateral distal extension base removable partial denture. Individual simulants were used for tooth structure, periodontal ligament, and alveolar bone. Three designs were fabricated: a major connector and clasps made from polyacetal resin, a metal framework as the major connector with polyacetal resin clasp and denture base, and a traditional metal framework I-bar removable partial denture. Simulated posterior bilateral and unilateral occlusal loads were applied to the removable partial dentures. Under bilateral and left side unilateral loading, the highest stress was observed adjacent to the left side posterior teeth with the polyacetal removable partial denture. The lowest stress was seen with the traditional metal framework. Unilateral loads on the right edentulous region produced similar distributed stress under the denture base with all three designs but a somewhat higher intensity with the polyacetal framework. The polyacetal resin removable partial denture concentrated the highest stresses to the abutment and the bone. The traditional metal framework I-bar removable partial denture most equitably distributed force. The hybrid design that combined a metal framework and polyacetal clasp and denture base may be a viable alternative when aesthetics are of primary concern.

  14. About Applications of the Fixed Point Theory

    Directory of Open Access Journals (Sweden)

    Bucur Amelia

    2017-06-01

    Full Text Available The fixed point theory is essential to various theoretical and applied fields, such as variational and linear inequalities, the approximation theory, nonlinear analysis, integral and differential equations and inclusions, the dynamic systems theory, mathematics of fractals, mathematical economics (game theory, equilibrium problems, and optimisation problems and mathematical modelling. This paper presents a few benchmarks regarding the applications of the fixed point theory. This paper also debates if the results of the fixed point theory can be applied to the mathematical modelling of quality.

  15. The 1994 Fermilab Fixed Target Program

    International Nuclear Information System (INIS)

    Conrad, J.

    1994-11-01

    This paper highlights the results of the Fermilab Fixed Target Program that were announced between October, 1993 and October, 1994. These results are drawn from 18 experiments that took data in the 1985, 1987 and 1990/91 fixed target running periods. For this discussion, the Fermilab Fixed Target Program is divided into 5 major topics: hadron structure, precision electroweak measurements, heavy quark production, polarization and magnetic moments, and searches for new phenomena. However, it should be noted that most experiments span several subtopics. Also, measurements within each subtopic often affect the results in other subtopics. For example, parton distributions from hadron structure measurements are used in the studies of heavy quark production

  16. Hybrid fixed point in CAT(0 spaces

    Directory of Open Access Journals (Sweden)

    Hemant Kumar Pathak

    2018-02-01

    Full Text Available In this paper, we introduce an ultrapower approach to prove fixed point theorems for $H^{+}$-nonexpansive multi-valued mappings in the setting of CAT(0 spaces and prove several hybrid fixed point results in CAT(0 spaces for families of single-valued nonexpansive or quasinonexpansive mappings and multi-valued upper semicontinuous, almost lower semicontinuous or $H^{+}$-nonexpansive mappings which are weakly commuting. We also establish a result about structure of the set of fixed points of $H^{+}$-quasinonexpansive mapping on a CAT(0 space.

  17. Adaptive approximation of higher order posterior statistics

    KAUST Repository

    Lee, Wonjung

    2014-02-01

    Filtering is an approach for incorporating observed data into time-evolving systems. Instead of a family of Dirac delta masses that is widely used in Monte Carlo methods, we here use the Wiener chaos expansion for the parametrization of the conditioned probability distribution to solve the nonlinear filtering problem. The Wiener chaos expansion is not the best method for uncertainty propagation without observations. Nevertheless, the projection of the system variables in a fixed polynomial basis spanning the probability space might be a competitive representation in the presence of relatively frequent observations because the Wiener chaos approach not only leads to an accurate and efficient prediction for short time uncertainty quantification, but it also allows to apply several data assimilation methods that can be used to yield a better approximate filtering solution. The aim of the present paper is to investigate this hypothesis. We answer in the affirmative for the (stochastic) Lorenz-63 system based on numerical simulations in which the uncertainty quantification method and the data assimilation method are adaptively selected by whether the dynamics is driven by Brownian motion and the near-Gaussianity of the measure to be updated, respectively. © 2013 Elsevier Inc.

  18. Bony landmark between the attachment of the medial meniscus posterior root and the posterior cruciate ligament: CT and MR imaging assessment

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Masataka; Furumatsu, Takayuki; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi [Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Department of Orthopaedic Surgery, Science of Functional Recovery and Reconstruction, Okayama (Japan)

    2017-08-15

    (1) To reveal the prevalence of the bony recess (posterior dimple) and (2) to determine the position of the posterior dimple on the tibial plateau using three-dimensional computed tomography (3DCT). In this study, a retrospective review of 112 patients was performed to identify the posterior dimple and to evaluate its position on 3DCT. Magnetic resonance images (MRIs) were also used to determine the positional relationship among the posterior cruciate ligament (PCL), medial meniscus posterior insertion (MMPI), and posterior dimple. The posterior dimple was observed in 100 of 112 knees (89.3%) on 3DCT. The center of the posterior dimple was 13.6 ± 0.8 mm from the medial tibial eminence apex. MRI showed that the posterior dimple separated the tibial attachment of the PCL and MMPI. This is the first study to discuss the prevalence and position of the bony recess in the posterior intercondylar fossa. (orig.)

  19. Bony landmark between the attachment of the medial meniscus posterior root and the posterior cruciate ligament: CT and MR imaging assessment

    International Nuclear Information System (INIS)

    Fujii, Masataka; Furumatsu, Takayuki; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-01-01

    (1) To reveal the prevalence of the bony recess (posterior dimple) and (2) to determine the position of the posterior dimple on the tibial plateau using three-dimensional computed tomography (3DCT). In this study, a retrospective review of 112 patients was performed to identify the posterior dimple and to evaluate its position on 3DCT. Magnetic resonance images (MRIs) were also used to determine the positional relationship among the posterior cruciate ligament (PCL), medial meniscus posterior insertion (MMPI), and posterior dimple. The posterior dimple was observed in 100 of 112 knees (89.3%) on 3DCT. The center of the posterior dimple was 13.6 ± 0.8 mm from the medial tibial eminence apex. MRI showed that the posterior dimple separated the tibial attachment of the PCL and MMPI. This is the first study to discuss the prevalence and position of the bony recess in the posterior intercondylar fossa. (orig.)

  20. Traumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Juan Felix Astoul Bonorino

    2015-01-01

    Full Text Available Many pathologic entities can produce a painful total knee replacement (TKR that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We present a new case of tibial insert dislocation in a High-Flex model that shares similarities and differences with the cases reported, facilitating the analysis of the potential causes, which still remain undefined.