WorldWideScience

Sample records for posterior capsular opacity

  1. Prevention of posterior capsular opacification

    NARCIS (Netherlands)

    Nibourg, Lisanne M; Gelens, Edith; Kuijer, Roelof; Hooymans, Johanna Mm; van Kooten, Theo G; Koopmans, Steven A

    Posterior capsular opacification (PCO) is a common complication of cataract surgery. The development of PCO is due to a combination of the processes of proliferation, migration, and transdifferentiation of residual lens epithelial cells (LECs) on the lens capsule. In the past decades, various forms

  2. Anterior capsular support for posterior chamber intraocular lenses following vitreous loss in endocapsular surgery

    Directory of Open Access Journals (Sweden)

    Jacob Pushpa

    1993-01-01

    Full Text Available We used anterior capsular support for posterior chamber intraocular lenses (PC IOLs in fourteen eyes with large posterior capsular ruptures. An endocapsular technique preserved the anterior capsule and facilitated implantation. With a median follow up of 8.5 months, all patients had a visual acuity of 6/9 or better. One lens was lost in the vitreous and one patient had a clinically significant cystoid macular edema. In the event of a posterior capsular rupture we suggest this technique as an alternative to anterior chamber or scleral-fixated lenses

  3. Isolated posterior capsular rupture following blunt head trauma

    Directory of Open Access Journals (Sweden)

    Mansour AM

    2014-11-01

    Full Text Available Ahmad M Mansour, Mahmoud O Jaroudi, Rola N Hamam, Fadi C Maalouf Department of Ophthalmology, American University of Beirut, Beirut, Lebanon Abstract: Closed-globe traumatic cataract is not uncommon in males in the pediatric age group. However, there is a relative paucity of literature on isolated posterior lens capsule rupture associated with closed-globe traumatic cataract. We report a case of a 6-year-old boy who presented with white cataract 1 day after blunt trauma to the forehead associated with posterior capsular rupture that was detected by B-scan ultrasonography preoperatively. No stigmata of trauma outside the posterior capsule could be detected by slit-lamp exam, funduscopy, and optical coherence tomography. Phacoemulsification with posterior chamber intraocular lens implant was performed 24 hours after trauma, with the patient achieving 6/6 visual acuity 1 week and 6 months after surgery. Our case is unique, being the youngest (amblyogenic age to be reported, with prompt surgical intervention, and with no signs of trauma outside the posterior capsule. Keywords: posterior capsule rupture, forehead trauma, traumatic cataract, pediatric cataract

  4. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division

  5. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user

  6. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  7. Capsular phimosis with complete occlusion of the anterior capsular opening after intact continuous curvilinear capsulorrhexis

    International Nuclear Information System (INIS)

    Al-Kharashi, Soliman A.; Al-Obailan, Majed

    2009-01-01

    Shrinkage and whitening of the anterior capsule opening - capsular contraction syndrome - is a well-known complication after continuous curvilinear capsulorrhexis. A 72-year-old women underwent continuous curvilinear capsulorrhexis, phacoemulsification, and implantation of posterior chamber intraocular lens with polymethylmethacrylate haptics. Four months postoperatively, the patient reported deterioration in visual acuity that was resulted due to complete occlusion of anterior capsular opening by fibrotic tissue. The fibrous membrane was excised surgically in capsulorrhexis fashion. (author)

  8. Management of subluxated capsular bag-fixated intraocular lenses using a capsular anchor.

    Science.gov (United States)

    Ton, Yokrat; Naftali, Modi; Gortzak, Ruth Lapid; Assia, Ehud I

    2016-05-01

    We describe the use of the capsular anchor (AssiAnchor) to manage a subluxated intraocular lens (IOL) in the capsular bag. The anchor comprises 2 prongs that hold the anterior lens capsule and a central rod that is sutured to the scleral wall, enabling centration of the IOL-capsular bag complex. Six pseudophakic patients presenting with subluxated posterior chamber IOLs in the capsular bag were operated on using the device. The anchor was used successfully in all cases, although in 2 cases only 1 prong was placed under the capsulorhexis edge. In 1 eye, 2 anchors were used 1 month apart following repeated traumatic zonular injury. The capsular bag holding the IOL remained centered and stable throughout the follow-up period. The anchoring device, which was originally designed to preserve the lens capsule and stabilize subluxated crystalline lenses, can also be used to treat subluxation of a capsular bag-fixated IOL. Dr. Assia is the inventor of the AssiAnchor, has a licensed patent of the anchor, and is consultant to Hanita Lenses. Dr. Lapid-Gortzak is a consultant to and speaker for Alcon Surgical, Inc., Hanita Lenses, Orca Surgical, and Sanoculis Ltd.; a speaker for Santen; and a consultant to Icon. Drs. Ton and Naftali have no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Effective Use of a Silicone-induced Capsular Flap in Secondary Asian Rhinoplasty

    Directory of Open Access Journals (Sweden)

    Jae Yong Jeong, MD

    2014-06-01

    Full Text Available Summary: Performing secondary rhinoplasty in patients who underwent primary rhinoplasty using a silicone implant is difficult due to thinning of nasal skin and formation of a capsule. Excess capsule formation can cause capsular contracture, resulting in short nose deformity or implant deviation, migration, or implant demarcation. Revision rhinoplasty using a capsular flap, dorsal silicone implant, and tip plasty was performed in 95 Korean patients (91 women and 4 men; mean age, 27 years who previously underwent primary augmentation rhinoplasty using silicone implants. The capsular flap was composed by creating a dual plane above the anterior capsule and below the posterior capsule. The existing silicone implant was removed, and a new silicone implant was placed under the posterior capsule. The patients were followed up for 6 months to 4 years (mean, 31.7 months. Of the 95 patients who underwent secondary augmentation rhinoplasty using a capsular flap, 88 patients (92.6% showed satisfactory results. There was no hematoma or nasal skin vascular compromise. There was no visible or palpable capsule resorption or recurrent capsular contracture. Early implant malpositioning (within 30 days postoperatively was observed in 4 patients, and tip shape dissatisfaction (within 60 days postoperatively was reported by 3 patients. Four patients underwent revision surgery and had successful outcomes. Nasal augmentation using a silicone implant and capsular flap in secondary rhinoplasty avoids complications caused by removal of the capsule. Recurrent capsule formation or clinically noticeable resorption of the capsular flap was not observed in this study.

  10. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  11. Prevention of after-cataract by application of heparin treatment of capsular tension ring in Marfan syndrome and subluxation of lens

    Directory of Open Access Journals (Sweden)

    Zhong-Qing Li

    2013-08-01

    Full Text Available AIM: To investigate the effect of heparin treatment on capsular tension ring(CTRin the prevention of after-cataract postoperative patients with Marfan syndrome and subluxation of lens.METHODS: Totally 34 cases(56 eyeswere divided randomly into experimental and control groups. Preoperative heparin 12500 units was added to 500mL Ringer's infusion, and CTR was dealt with heparin stock solution soak for 20 minutes in experimental group; there was no any drugs in the control group's solution, and CTR was not dealt with heparin. Postoperative IOP, anterior chamber reaction, corneal edema, IOL position, posterior capsular opacification were observed.RESULTS: There was statistically significant difference in the posterior capsular opacification between the heparin group(13.3%and the contral group no-heparin(69.2%(PCONCLUSION: The present results indicate that there is the preventive effect on posterior capsular opacification by CTR soaked in heparin in postoperative patients with Marfan syndrome and subluxation of lens, thus contributing to the recovery of visual function.

  12. [Cause analysis and management of severe dislocated or subluxated intraocular lenses in the capsular bag].

    Science.gov (United States)

    Wang, Wen-qing; Jia, Li-Li; Lu, Bin; Fang, Jian; Chen, Ying

    2006-05-01

    To analyze the causes of severe dislocated and subluxated intraocular lenses (IOL) in capsular bag and the relevancy with abnormal capsular constitution. The abnormality of capsular and the position of IOL were retrospectively analyzed by slit lamp and microscope in dilated pupil. Surgeries were performed in all of 31 cases in order to exchange or reposit the dislocated or subluxated lOL. Among 31 cases, there were 20 cases with the dislocated or subluxated IOL in the earlier postoperative period and 11 cases in the later postoperative period. The subluxated IOL in 5 cases (16.1%) were caused by the large rupture of the posterior capsular, and by the rupture of the posterior capsular in 9 cases (29.0%). A upward subluxated IOL developed in one case (3.2%) as the result of small rupture in the equater capsular. The subluxatd IOL in the anterior chamber in two cases (6.5%) was induced by the radial rupture of residual anterior capsular. The size of the IOLs in 2 cases were not matched to the diameter of the capsule bag. The dislocated IOL into the vitreous in 2 cases was caused by the rupture of the superior capsular. The subluxated IOL in 2 cases (6.5%) was caused by the zonal finers rupture due to trauma. The severe disfiguration of the IOL haptic was found in one case. The dislocated IOL in 6 cases (19.4%) was caused by asymmetric capsular shrinkage. A subluxated IOL in one case was resulted from the zonular defects with pseudoexfoliation syndrome. The postoperative corrected visual acuity was 0.5 - 1.0 in 24 eyes, 0.1 - 0.4 in 6 eyes, and 0.05 in one eye. There are several causes for the dislocated or subluxated IOL. The correction of the IOL position should depend on the cause for the dislocated or subluxated IOL.

  13. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  14. Epidemiology, Etiology, and Prevention of Late IOL-Capsular Bag Complex Dislocation: Review of the Literature

    OpenAIRE

    Ascaso, Francisco J.; Huerva, Valent?n; Grzybowski, Andrzej

    2015-01-01

    Posterior chamber intraocular lens (PC-IOL) subluxation is uncommon but represents one of the most serious complications following phacoemulsification. Late spontaneous IOL-capsular bag complex dislocation is defined as occurring three months or later following cataract surgery. Unlike early IOL dislocation, late spontaneous IOL dislocation is due to a progressive zonular dehiscence and contraction of the capsular bag many years what seemed to be uneventful surgery. In recent years, late in-t...

  15. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting.

    Science.gov (United States)

    Kim, Jin-Soo; Choi, Jung Yeol; Kwon, Ji-Won; Wee, Won Ryang; Han, Young Keun

    2018-01-01

    To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting. A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern). The best corrected visual acuity (BCVA), intraocular pressure (IOP), refractive error, endothelial cell count (ECC), anterior segment parameters, including anterior chamber depth (ACD) and anterior chamber angle (ACA) were measured before and 1mo after the laser posterior capsulotomy. In both groups, the BCVA improved significantly ( P <0.001 for the modified round pattern group, P =0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased ( P <0.001 for both) and the ACA significantly increased ( P =0.001 for the modified round pattern group and P =0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups. Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  16. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting

    Directory of Open Access Journals (Sweden)

    Jin-Soo Kim

    2018-02-01

    Full Text Available AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG laser posterior capsulotomy with vitreous strand cutting METHODS: A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern. The best corrected visual acuity (BCVA, intraocular pressure (IOP, refractive error, endothelial cell count (ECC, anterior segment parameters, including anterior chamber depth (ACD and anterior chamber angle (ACA were measured before and 1mo after the laser posterior capsulotomy. RESULTS: In both groups, the BCVA improved significantly (P<0.001 for the modified round pattern group, P=0.001 for the cruciate pattern group; the IOP and ECC did not significantly change. The ACD significantly decreased (P<0.001 for both and the ACA significantly increased (P=0.001 for the modified round pattern group and P=0.034 for the cruciate group. The extent of changes in these parameters was not significantly different between the groups. CONCLUSION: Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  17. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children.

    Science.gov (United States)

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Tertiary care setting. We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90 degrees up to 210 degrees after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO). Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA) in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation.

  18. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    Directory of Open Access Journals (Sweden)

    Das Pranab

    2009-01-01

    Full Text Available Purpose : To evaluate the outcome of intraocular lens (IOL implantation using capsular tension ring (CTR in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO. Results : Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Conclusions : Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation

  19. Management of subluxated capsular bag-fixated intraocular lenses using a capsular anchor

    NARCIS (Netherlands)

    Ton, Yokrat; Naftali, Modi; Lapid Gortzak, Ruth; Assia, Ehud I.

    2016-01-01

    We describe the use of the capsular anchor (AssiAnchor) to manage a subluxated intraocular lens (IOL) in the capsular bag. The anchor comprises 2 prongs that hold the anterior lens capsule and a central rod that is sutured to the scleral wall, enabling centration of the IOL-capsular bag complex. Six

  20. Terrien's marginal degeneration accompanied by latticed stromal opacities.

    Science.gov (United States)

    Zhang, Yibing; Jia, Hui

    2014-05-01

    We report a case of Terrien's marginal degeneration (TMD) with a unilaterally typical narrow band of peripheral corneal stroma thinning, accompanied by the presence of an unusual network of opacities diffusing throughout the anterior stroma layers. A 43-year-old woman presented with superior nasal peripheral corneal thinning and an unusual network of polygonal stromal opacities in the anterior corneal stroma of the right eye. Latticed corneal changes were unusually extensive and distributed diffusely in the stroma. No abnormalities were found in the corneal epithelium and in the basal epithelial cells. No noticeable changes were found in the left eye. Because of a progressively worse ocular irritation of the right eye, a diagnosis of TMD was made for this patient. This case of TMD accompanied by keratopathy was unusual. The branching stromal lattice pattern of the corneal opacities was difficult to distinguish from lattice corneal dystrophy. In this case, the polygonal stromal opacities were located in the anterior corneal stroma and therefore were distinguished from a similar manifestation in posterior crocodile shagreen.

  1. A Rare Form of Corneal Opacity Associated with Spondyloepiphyseal Dysplasia Congenita

    Directory of Open Access Journals (Sweden)

    Yuichiro Ishida

    2018-02-01

    Full Text Available A 13-year-old Japanese female diagnosed with spondyloepiphyseal dysplasia congenita (SEDC was referred for ophthalmologic evaluation. Examination with slit-lamp and optical coherence tomography revealed bilateral thin cornea with diffuse corneal opacity which was localised at the posterior stromal depth in the central cornea. Unlike the two previously reported cases of diffuse and nodular patterns of corneal opacity in SEDC, the current case exhibited a rare form of corneal opacity. SEDC is one of the type II collagenopathies, characterised by dwarfism because the mutations in COL2A1 prevent bone growth. Although the existence of type II collagen has not been reported in the human corneal stroma, the aetiology of the opacity in the corneal stroma in SEDC type II collagenopathy is of interest.

  2. Síndrome do andar superior da cápsula interna. Hemiplegia sensitivo-motora capsular

    Directory of Open Access Journals (Sweden)

    A. Borges Fortes

    1944-03-01

    Full Text Available Desde Türck (1859 os autores têm se preocupado com a passagem de fibras sensitivas pela cápsula interna. Muitas escolas neurológicas têm estudado a questão não só sob o ponto de vista clínico mas também anatômico e experimental. O autor passa em revista a opinião dos autores franceses (Charcot, Dejerine, Roussy, Long, etc. baseados na anátomo-clínica; dos ingleses com base na experimentação (Horsley, Beevor, Grünbaum, Sherrington, Oppenheim; suíços (Monakow e americanos (Grinker sobre as desordens sensitivas nas lesões da cápsula interna. O autor apresenta dois casos anátomo-clínicos de hemiplegia com perturbações sensitivas devidas a lesões da cápsula interna comprovadas anatomicamente. O tálamo estava indene em ambos os casos. A cápsula interna é um diedro formado pelo encontro de dois planos: o segmento anterior e o segmento posterior. Pela parte mais alta (andar superior do segmento posterior passam as fibras que saem do tálamo em busca da cortiça parietal (fibras tálamo-parietais, as que descem ao pedúnculo cerebral (fibras piramidais e as que ficam entre o núcleo lenticular e o tálamo (fibras extra-piramidais. No andar inferior do mesmo segmento passam somente as fibras piramidais. O autor estuda do ponto de vista anátomo-clínico a síndrome talâmica de Dejerine e Roussy, os estados talâmicos (Austregesilo e Colares e a hemiplegia capsular puramente motora. Mostra a inexistência de alterações sensitivas nas hemiplegias devidas à lesão do andar inferior da cápsula interna posterior. Estuda a síndrome do andar superior da cápsula interna posterior ou hemiplegia sensitivo-motora capsular. Documenta dois casos de hemiplegia sensitivo-motora com o estudo anatômico no qual se viu a lesão do andar superior do braço posterior da cápsula interna e integridade do tálamo. Salienta as diferenças existentes entre a mão talâmica e a capsular e chama a atenção para a contratura em flexão com

  3. A stepwise approach for the management of capsular contraction syndrome in hinge-based accommodative intraocular lenses

    Directory of Open Access Journals (Sweden)

    Page TP

    2016-06-01

    Full Text Available Timothy P Page,1 Jeffrey Whitman2 1Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, MI, 2Key-Whitman Eye Center, Dallas, TX, USA Purpose: The aims of this study are to define the various stages of capsular contraction syndrome (CCS and its effect on refractive error with hinge-based accommodating intraocular lenses (IOLs and to describe a systematic approach for the management of the different stages of CCS. Methods: Hinge-based accommodative IOLs function via flexible hinges that vault the optic forward during accommodation. However, it is the flexibility of the IOL that makes it prone to deformation in the event of CCS. The signs of CCS are identified and described as posterior capsular striae, fibrotic bands across the anterior or posterior capsule, and capsule opacification. Various degrees of CCS may affect hinge-based accommodating IOLs in a spectrum from subtle changes in IOL appearance to significant increases in refractive error and loss of uncorrected visual acuity. The signs of CCS and its effect on IOL position and the resulting changes in refractive error are matched to appropriate treatment plans. Results: A surgeon can avoid CCS and manage the condition if familiar with the early signs of CCS. If CCS is identified, yttrium–aluminum–garnet laser capsulotomy should be considered. If moderate CCS occurs, it may be effectively treated with insertion of a capsular tension ring. If CCS is allowed to progress to advanced stages, an IOL exchange may be necessary. Conclusion: Surgeons should be familiar with the stages of CCS and subsequent interventions. The steps outlined in this article help to guide surgeons in the prevention and management of CCS with hinge-based accommodative IOLs in order to provide improved refractive outcomes for patients. Keywords: z-syndrome, pseudophakic tilt, IOL subluxation, CTR, capsular tension ring, capsular fibrosis

  4. A and B mode ultrasonography in preoperative evaluation of lens and posterior segment of dogs eyes with cataract

    Directory of Open Access Journals (Sweden)

    Bianca C. Martins

    2010-02-01

    Full Text Available Ultrasonography of the lens and posterior segment is an indispensable step in the preoperative evaluation of dogs with cataracts, since ophthalmoscopy is not feasible when there is opacification of the lens. This study evaluated the echographic conditions of cataractous lens and fundus of the eye in dogs affected by cataracts. The study was conducted in 30 dogs (56 eyes, 10 males and 20 females, with different types of cataracts at different stages of development. Echography in A and B modes, simultaneously, was carried out for the examination of the lens and posterior segment. The examinations revealed anterior cortical, posterior cortical and nuclear cataract in 12 eyes (21.4%, anterior cortical, posterior cortical, nuclear and posterior capsular in 23 eyes (41%, anterior cortical, posterior cortical and posterior capsular cataract in one eye (1.7%, anterior cortical and nuclear cataract in one eye (1.7%, anterior cortical, nuclear and posterior capsular cataract in five eyes (8.9%, and anterior cortical cataract in seven eyes (12.5%. Abnormal ultrasonographic alterations were observed in the posterior segment in 26 eyes evaluated (46.4%. Vitreal degeneration was detected in 12 eyes (21.4%, images of vitreal exudate or hemorrhage in seven eyes (12.5%, persistence of hyaloid artery in four eyes (7.1% and lens subluxation in three eyes (5.3%. The results obtained reiterate the importance of ultrasonography in canine patients presented for cataract surgery given that alterations of the posterior segment are difficult to identify in a clinical examination when the lens is opacified.A ultrassonografia do segmento posterior do bulbo do olho é etapa indispensável na avaliação de cães com catarata que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Este estudo avaliou as condições ecográficas da lente cataratogênica e do fundo de olho de c

  5. [Subluxation of hydrophilic acrylate intraocular lenses due to massive capsular fibrosis].

    Science.gov (United States)

    Kramer, S; Schröder, A C; Brückner, K; Jonescu-Cuypers, C; Seitz, B

    2010-05-01

    Compared with other biomaterials, hydrophilic acrylate provides better uveal biocompatibility, lower adhesion rates of bacteria and silicone oil, and less glare. Because of reduced capsular biocompatibility, increased fibrosis may initiate dislocation of the intraocular lens (IOL). In six eyes of four patients, enhanced fibroses led to IOL dislocation, leading to an IOL exchange an average of 40 weeks after implantation of the same hydrophilic acrylate lens type. Predisposing factors were found in 90% of all reported cases of IOL dislocation in the literature, but not in the cases described here. The lens type that was implanted was unable to adapt to the massive fibrosis induced by its hydrophilic biomaterial. The pattern of lens opacification should receive attention when one is choosing an IOL type. Eyes showing pseudoexfoliation syndrome as well as post-uveitis eyes might require a hydrophilic IOL for less cellular reaction, whereas a posterior subcapsular cataract might need a hydrophobic IOL to prevent a massive capsular fibrosis. In the case of increased capsular contraction, unreflected YAG laser capsulotomy may result in IOL subluxation when the lens design cannot handle capsule shrinkage, as demonstrated here.

  6. Terrien’s Marginal Degeneration Accompanied by Latticed Stromal Opacities

    Science.gov (United States)

    Zhang, Yibing; Jia, Hui

    2014-01-01

    ABSTRACT Purpose We report a case of Terrien’s marginal degeneration (TMD) with a unilaterally typical narrow band of peripheral corneal stroma thinning, accompanied by the presence of an unusual network of opacities diffusing throughout the anterior stroma layers. Case Report A 43-year-old woman presented with superior nasal peripheral corneal thinning and an unusual network of polygonal stromal opacities in the anterior corneal stroma of the right eye. Latticed corneal changes were unusually extensive and distributed diffusely in the stroma. No abnormalities were found in the corneal epithelium and in the basal epithelial cells. No noticeable changes were found in the left eye. Because of a progressively worse ocular irritation of the right eye, a diagnosis of TMD was made for this patient. Conclusions This case of TMD accompanied by keratopathy was unusual. The branching stromal lattice pattern of the corneal opacities was difficult to distinguish from lattice corneal dystrophy. In this case, the polygonal stromal opacities were located in the anterior corneal stroma and therefore were distinguished from a similar manifestation in posterior crocodile shagreen. PMID:24681833

  7. Imaging findings in posterior instability of the shoulder

    International Nuclear Information System (INIS)

    Harish, Srinivasan; Rebello, Ryan; O'Neill, John; Nagar, Arpit; Moro, Jaydeep; Pugh, David

    2008-01-01

    Posterior shoulder instability refers to the symptoms and signs resulting from excessive posterior translation of the humerus. Magnetic resonance (MR) imaging is the radiological modality of choice in the diagnostic assessment of posterior instability. Computed tomography (CT) is useful in the evaluation of osseous abnormalities associated with posterior instability. A detailed description of the posterior osseous and labroligamentous abnormalities has evolved recently, and many variant lesions of the posteroinferior labrum and/or capsular structures have been described. As the recommended surgical management of lesions associated with posterior instability is a lesion-specific approach, awareness of the specific lesions that have been described in association with posterior instability helps in pre-surgical planning. The purpose of this article is to review the classification of, and injury mechanisms leading to, posterior shoulder instability and to describe imaging findings associated with posterior instability, with emphasis on MR imaging. (orig.)

  8. Imaging findings in posterior instability of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Harish, Srinivasan; Rebello, Ryan; O' Neill, John [St. Joseph' s Healthcare, Department of Diagnostic Imaging, Hamilton, ON (Canada); McMaster University, Faculty of Health Sciences, Hamilton (Canada); Nagar, Arpit [St. Joseph' s Healthcare, Department of Diagnostic Imaging, Hamilton, ON (Canada); Moro, Jaydeep [St. Joseph' s Healthcare, Department of Orthopedic Surgery, Hamilton, ON (Canada); McMaster University, Faculty of Health Sciences, Hamilton (Canada); Pugh, David [Brantford General Hospital, Department of Orthopedic Surgery, Brantford, ON (Canada)

    2008-08-15

    Posterior shoulder instability refers to the symptoms and signs resulting from excessive posterior translation of the humerus. Magnetic resonance (MR) imaging is the radiological modality of choice in the diagnostic assessment of posterior instability. Computed tomography (CT) is useful in the evaluation of osseous abnormalities associated with posterior instability. A detailed description of the posterior osseous and labroligamentous abnormalities has evolved recently, and many variant lesions of the posteroinferior labrum and/or capsular structures have been described. As the recommended surgical management of lesions associated with posterior instability is a lesion-specific approach, awareness of the specific lesions that have been described in association with posterior instability helps in pre-surgical planning. The purpose of this article is to review the classification of, and injury mechanisms leading to, posterior shoulder instability and to describe imaging findings associated with posterior instability, with emphasis on MR imaging. (orig.)

  9. Ligamentous and capsular restraints to experimental posterior elbow joint dislocation

    DEFF Research Database (Denmark)

    Deutch, S.R.; Olsen, B.S.; Jensen, S.L.

    2003-01-01

    the anterior capsule and the lateral collateral ligament complex (LCLC), whereas in the flexed elbow the anterior capsule did not have a stabilizing effect. In flexed joint positions, the LCLC seems to be the only immediate stabilizer against PEFR, and thereby against posterolateral instability and possibly...... against posterior dislocation. The medial collateral ligament did not have any immediate stabilizing effect, but it prevented the final step of the posterior dislocation....

  10. Open capsular and ligament reconstruction with semitendinosus hamstring autograft successfully controls superior and posterior translation for type V acromioclavicular joint dislocation.

    Science.gov (United States)

    Garofalo, Raffaele; Ceccarelli, Enrico; Castagna, Alessandro; Calvisi, Vittorio; Flanagin, Brody; Conti, Marco; Krishnan, Sumant G

    2017-07-01

    Appropriate surgical management for type V complete acromioclavicular (AC) joint dislocation remains controversial. The purpose of this paper is to retrospectively report the clinical and radiographic outcomes of an open surgical technique consisting for AC joint ligamentous and capsular reconstruction using autologous hamstring tendon grafts and semi-permanent sutures. Between January 2005 and December 2011, 32 consecutive patients with symptomatic type V complete AC joint dislocation underwent surgical treatment using the same technique. The median time from injury to surgery was 45 days (range 24-90). The average median postoperative clinical and radiographic follow-up time was 30 months (range 24-33). Clinical outcomes measures included the ASES score, the visual analog score (VAS), and subjective patient satisfaction score. Minimum follow-up was 2 years. ASES score increased from a median of 38.2 ± 6.2 preoperative to 92.1 ± 4.7 postoperatively (p ≤ 0.05). The median VAS score improved from 62 mm (range 45-100 mm) preoperatively to 8 mm (range 0-20 mm) at final follow-up (p ≤ 0.05). No patient experienced pain or discomfort with either direct palpation of the AC joint or with cross-body adduction. Final radiographs demonstrated symmetric AC joint contour in 25/32 (78%) patients. Seven patients (22%) radiographically demonstrated superior translation of the distal clavicle relative to the superior margin of the acromion but less than 50% of the clavicular width. 30/32 patients (93%) were able to return to their pre-injury level of work and sports activities. This novel surgical technique using a free graft and braided suture for simultaneous coracoclavicular ligament and AC joint capsular reconstruction successfully controls superior and posterior translations after type V AC joint dislocation and minimizes the incidence of persistent postoperative AC joint subluxation. Retrospective case series, Level IV.

  11. Epidemiology, Etiology, and Prevention of Late IOL-Capsular Bag Complex Dislocation: Review of the Literature

    Directory of Open Access Journals (Sweden)

    Francisco J. Ascaso

    2015-01-01

    Full Text Available Posterior chamber intraocular lens (PC-IOL subluxation is uncommon but represents one of the most serious complications following phacoemulsification. Late spontaneous IOL-capsular bag complex dislocation is defined as occurring three months or later following cataract surgery. Unlike early IOL dislocation, late spontaneous IOL dislocation is due to a progressive zonular dehiscence and contraction of the capsular bag many years what seemed to be uneventful surgery. In recent years, late in-the-bag IOL subluxation or dislocation has been reported with increasing frequency, having a cumulative risk of IOL dislocation following cataract extraction of 0.1% after 10 years and 1.7% after 25 years. A predisposition to zonular insufficiency and capsular contraction is identified in 90% of reviewed cases. Multiple conditions likely play a role in contributing to this zonular weakness and capsular contraction. Pseudoexfoliation is the most common risk factor, accounting for more than 50% of cases. Other associated conditions predisposing to zonular dehiscence are aging, high myopia, uveitis, trauma, previous vitreoretinal surgery, retinitis pigmentosa, diabetes mellitus, atopic dermatitis, previous acute angle-closure glaucoma attack, and connective tissue disorders. The recognition of these predisposing factors suggests a modified approach in cases at risk. We review certain measures to prevent IOL-bag complex luxation that have been proposed.

  12. Epidemiology, Etiology, and Prevention of Late IOL-Capsular Bag Complex Dislocation: Review of the Literature.

    Science.gov (United States)

    Ascaso, Francisco J; Huerva, Valentín; Grzybowski, Andrzej

    2015-01-01

    Posterior chamber intraocular lens (PC-IOL) subluxation is uncommon but represents one of the most serious complications following phacoemulsification. Late spontaneous IOL-capsular bag complex dislocation is defined as occurring three months or later following cataract surgery. Unlike early IOL dislocation, late spontaneous IOL dislocation is due to a progressive zonular dehiscence and contraction of the capsular bag many years what seemed to be uneventful surgery. In recent years, late in-the-bag IOL subluxation or dislocation has been reported with increasing frequency, having a cumulative risk of IOL dislocation following cataract extraction of 0.1% after 10 years and 1.7% after 25 years. A predisposition to zonular insufficiency and capsular contraction is identified in 90% of reviewed cases. Multiple conditions likely play a role in contributing to this zonular weakness and capsular contraction. Pseudoexfoliation is the most common risk factor, accounting for more than 50% of cases. Other associated conditions predisposing to zonular dehiscence are aging, high myopia, uveitis, trauma, previous vitreoretinal surgery, retinitis pigmentosa, diabetes mellitus, atopic dermatitis, previous acute angle-closure glaucoma attack, and connective tissue disorders. The recognition of these predisposing factors suggests a modified approach in cases at risk. We review certain measures to prevent IOL-bag complex luxation that have been proposed.

  13. Outcomes of Surgery for Posterior Polar Cataract Using Torsional Ultrasound

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2013-10-01

    Full Text Available Purpose: The aim of this study is to report outcomes of surgery for posterior polar cataract using torsional ultrasound. Material and Method: Medical records of 26 eyes of 21 consecutive patients with posterior polar cataract who had cataract surgery using the torsional phacoemulsification were evaluated retrospectively. The surgical procedure used, phacoemulsification parameters, intraoperative complications, and postoperative visual outcome were recorded. Results: Of the 26 eyes, 24 (92.3% had small to medium posterior polar opacity. Two eyes had large opacity. All surgeries were performed using the torsional handpiece. Posterior capsule rupture occurred in 4 (15.3% eyes. The mean visual acuity improved significantly after surgery (p<0.001. The postoperative visual acuity was worse than 20/20 in 5 eyes. The cause of the low acuity was amblyopia. Discussion: Successful surgical results and good visual outcome can be achieved with phacoemulsification using the torsional handpiece. (Turk J Ophthalmol 2013; 43: 345-7

  14. Estrategias de prevención de la opacidad de la cápsula posterior Strategies for the prevention of the posterior capsule opacification

    Directory of Open Access Journals (Sweden)

    Iván Hernández López

    2010-01-01

    de la opacidad del saco capsular.The posterior capsule opacification (PCO is the most important aspect in the cataract surgery nowadays. It continues being the more frequent late postoperative complication after cataract surgery associated with decrease of the visual acuity and other visual problems that lead to important social, economical and medical impacts. The laser capsulotomy is an effective procedure for the treatment of this complication but it is far from being the ideal method since it can be associated to considerable complications. This is the reason why several research studies recently have directed their attention to PCO-preventing strategies such as the design of intraocular lenses, modified and/or improved surgical techniques, additional implants, use of cytotoxic agents and drugs as well as new technologies. The gene therapy, among the novel interventions in study, seems to be a promising strategy in this field. Up to the present, there is not a unique method that avoids in a definitive way the development of the capsular opacification. The ophthalmologists should use the combination of all these methods available which have demonstrated a proved effectiveness in the reduction of PCO. Attaining long-term excellent visual result is the main purpose of the modern cataract surgery as well as paving the road towards novel surgical interventions for the treatment of presbyopia in patients older than 40 years. In order to achieve that goal, it is essential to avoid the opacification of the posterior capsule, even more with the use of multifocal and accommodative lenses that are more vulnerable to the opacity than the monofocal lenses. Therefore, we may dare to say that the biggest breakthrough in the modern cataract surgery is still awaiting: the definitive eradication of posterior capsule opacification.

  15. Effects of hip joint position and intra-capsular volume on hip joint intra-capsular pressure: a human cadaveric model

    Directory of Open Access Journals (Sweden)

    Tse Paul

    2009-04-01

    Full Text Available Abstract Background Increase in hip intra-capsular pressure has been implicated in various hip pathologies, such as avascular necrosis complicating undisplaced femoral neck fracture. Our study aimed at documenting the relationship between intra-capsular volume and pressure in various hip positions. Methods Fifty-two cadaveric hips were studied. An electronic pressure-monitoring catheter recorded the intra-capsular hip pressure after each instillation of 2 ml of normal saline and in six hip positions. Results In neutral hip position, the control position for investigation, intra-capsular pressure remained unchanged when its content was below 10 ml. Thereafter, it increased exponentially. When the intra-capsular volume was 12 ml, full abduction produced a 2.1-fold increase (p = 0.028 of the intra-capsular hip joint pressure; full external rotation and full internal rotation increased the pressure by at least 4-fold (p Conclusion Intra-capsular pressure increases with its volume, but with a wide variation with different positions. It would be appropriate to recommend that hips with haemarthrosis or effusion should be positioned in 45-degree flexion.

  16. A stepwise approach for the management of capsular contraction syndrome in hinge-based accommodative intraocular lenses.

    Science.gov (United States)

    Page, Timothy P; Whitman, Jeffrey

    2016-01-01

    The aims of this study are to define the various stages of capsular contraction syndrome (CCS) and its effect on refractive error with hinge-based accommodating intraocular lenses (IOLs) and to describe a systematic approach for the management of the different stages of CCS. Hinge-based accommodative IOLs function via flexible hinges that vault the optic forward during accommodation. However, it is the flexibility of the IOL that makes it prone to deformation in the event of CCS. The signs of CCS are identified and described as posterior capsular striae, fibrotic bands across the anterior or posterior capsule, and capsule opacification. Various degrees of CCS may affect hinge-based accommodating IOLs in a spectrum from subtle changes in IOL appearance to significant increases in refractive error and loss of uncorrected visual acuity. The signs of CCS and its effect on IOL position and the resulting changes in refractive error are matched to appropriate treatment plans. A surgeon can avoid CCS and manage the condition if familiar with the early signs of CCS. If CCS is identified, yttrium-aluminum-garnet laser capsulotomy should be considered. If moderate CCS occurs, it may be effectively treated with insertion of a capsular tension ring. If CCS is allowed to progress to advanced stages, an IOL exchange may be necessary. Surgeons should be familiar with the stages of CCS and subsequent interventions. The steps outlined in this article help to guide surgeons in the prevention and management of CCS with hinge-based accommodative IOLs in order to provide improved refractive outcomes for patients.

  17. Evidence for Rare Capsular Switching in Streptococcus agalactiae▿

    Science.gov (United States)

    Martins, Elisabete Raquel; Melo-Cristino, José; Ramirez, Mário

    2010-01-01

    The polysaccharide capsule is a major antigenic factor in Streptococcus agalactiae (Lancefield group B streptococcus [GBS]). Previous observations suggest that exchange of capsular loci is likely to occur rather frequently in GBS, even though GBS is not known to be naturally transformable. We sought to identify and characterize putative capsular switching events, by means of a combination of phenotypic and genotypic methods, including pulsed-field gel electrophoretic profiling, multilocus sequence typing, and surface protein and pilus gene profiling. We show that capsular switching by horizontal gene transfer is not as frequent as previously suggested. Serotyping errors may be the main reason behind the overestimation of capsule switching, since phenotypic techniques are prone to errors of interpretation. The identified putative capsular transformants involved the acquisition of the entire capsular locus and were not restricted to the serotype-specific central genes, the previously suggested main mechanism underlying capsular switching. Our data, while questioning the frequency of capsular switching, provide clear evidence for in vivo capsular transformation in S. agalactiae, which may be of critical importance in planning future vaccination strategies against this pathogen. PMID:20023016

  18. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  19. Distrofia corneana policromática posterior Polychromatic posterior corneal dystrophy

    Directory of Open Access Journals (Sweden)

    Patrick Frensel de Moraes Tzelikis

    2007-08-01

    Full Text Available Os autores descrevem quatro raros casos de distrofia corneana policromática posterior, ainda não descrito na literatura nacional. Observam-se opacidades puntiformes, policromáticas, de tamanho uniforme, localização estromal profunda, distribuídas de limbo a limbo e que não interferem na acuidade visual. É apresentada uma revisão dos casos de distrofia pré-Descemet existentes na literatura.The authors describe four rare cases of polychromatic posterior corneal dystrophy, not describe in national literature. The opacities are deep in the stroma, dotlike, polychromatic, uniform in size, distributed from limbus to limbus, leading no reduction in visual acuity. It is also presented a bibliographic review of pre-Descemet's dystrophy.

  20. Patient with pontine warning syndrome and bilateral posterior internuclear ophthalmoplegia: case report

    Directory of Open Access Journals (Sweden)

    Su Li

    2010-06-01

    Full Text Available Abstract Background Capsular warning syndrome was first described in 1993, featured with repetitive episodes of motor and/or sensory dysfunction without cortical signs. Recently, it has been demonstrated that clinically typical capsular warning syndrome can be associated with pontine infarct and the term “pontine warning syndrome� was coined. Case Presentation A 54-year-old woman with a history of hypertension was seen with profound left-sided hemiplegia. She had had 3 episodes of left-sided weakness before complete hemiplegia. Her speech was slurred. Left central facial palsy and hemiglossoplegia were presented. Her left plantar response was extensor and bilateral posterior internuclear ophthalmoplegia was seen on neurologic examination. Biochemical tests revealed hyperglycemia and dyslipidemia on the next day. MRI demonstrated an acute right paramedian pontine infarct. The patient was commenced on oral clopidogrel, atorvastatin and acarbose. After 23 days of hospitalization, she was discharged with severe left hemiplegia. Conclusions 1 Pontine warning syndrome may be underestimated and understudied. 2 Posterior internuclear ophthalmoplegia is a rare clinical sign in cerebrovascular diseases, while it can help to locate a brainstem lesion rather than an internal capsular one. 3 Blood pressure lowing administration may be improper for patients with pontine warning syndrome.

  1. Long-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses in children: An ultrasound biomicroscopy study.

    Directory of Open Access Journals (Sweden)

    Yun-E Zhao

    Full Text Available To evaluate the long-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses (IOLs in children after pediatric cataract surgery.IOL was implanted in the ciliary sulcus in 21 eyes of 14 children, and in the capsular bag in 19 eyes of 12 children for the treatment of pediatric cataract in an institutional setting. Ultrasound biomicroscopy (UBM was performed. Main outcome measures included IOL decentration, IOL tilt, anterior chamber depth (ACD, angle-opening distance at 500 μm (AOD500, trabecular-iris angle (TIA, best-corrected visual acuity (BCVA, intraocular pressure (IOP, and incidence of postoperative complications.The mean follow-up period was 6.81 ± 1.82 years. Comparing to the capsular bag fixation group, the ciliary sulcus fixation group had higher vertical IOL decentration, horizontal IOL tilt, and vertical IOL tilt (p = 0.02, 0.01,0.01, respectively, higher incidence of iris-IOL contact and peripheral anterior synechia (p = 0.001, 0.03, respectively, smaller ACD, AOD500, and TIA (p = 0.02, 0.03, 0.04, respectively, higher mean IOP (17.10 ±6.06 mmHg vs.14.15± 4.74 mmHg, p = 0.01, and higher incidence of secondary glaucoma (28.57% vs. 10.53%, p = 0.007.There was no significant difference between the two groups with regard to the BCVA, refractive errors, incidence of myopic shift, nystagmus, strabismus, and visual axis opacity.Ciliary sulcus fixation of IOLs in pediatric eyes may increase IOL malposition and crowding of the anterior segment, and may associate with a higher risk of secondary glaucoma compared to capsular bag fixation of IOLs.

  2. Posterior labral injury in contact athletes.

    Science.gov (United States)

    Mair, S D; Zarzour, R H; Speer, K P

    1998-01-01

    Nine athletes (seven football offensive linemen, one defensive lineman, and one lacrosse player) were found at arthroscopy to have posterior labral detachment from the glenoid. In our series, this lesion is specific to contact athletes who engage their opponents with arms in front of the body. All patients had pain with bench pressing and while participating in their sport, diminishing their ability to play effectively. Conservative measures were ineffective in relieving their symptoms. Examination under anesthesia revealed symmetric glenohumeral translation bilaterally, without evidence of posterior instability. Treatment consisted of glenoid rim abradement and posterior labral repair with a bioabsorbable tack. All patients returned to complete at least one full season of contact sports and weightlifting without pain (minimum follow-up, > or = 2 years). Although many injuries leading to subluxation of the glenohumeral joint occur when an unanticipated force is applied, contact athletes ready their shoulder muscles in anticipation of impact with opponents. This leads to a compressive force at the glenohumeral joint. We hypothesize that, in combination with a posteriorly directed force at impact, the resultant vector is a shearing force to the posterior labrum and articular surface. Repeated exposure leads to posterior labral detachment without capsular injury. Posterior labral reattachment provides consistently good results, allowing the athlete to return to competition.

  3. Early versus late traumatic cataract surgery and intraocular lens implantation.

    Science.gov (United States)

    Tabatabaei, S A; Rajabi, M B; Tabatabaei, S M; Soleimani, M; Rahimi, F; Yaseri, M

    2017-08-01

    PurposeTo determine the proper time for traumatic cataract surgery after open globe injuries.SettingFarabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.DesignRandomized clinical trial.Patients and methodsIn a randomized clinical trial, 30 eyes with traumatic cataract after open globe injury with IOL implantation underwent early (in the first week after the trauma) and 30 eyes underwent late cataract surgery (from the first to second month after the trauma). We excluded patients who were under 12-year-old. All patients were visited at 1 week, 4 weeks, 12 weeks, and 6 months after surgery. In each visit, patients were examined regarding visual acuity, intraocular pressure (IOP), anterior chamber inflammation, IOL position, and posterior synechiae. In addition, posterior segment evaluation and fundoscopy were performed. Intraoperative complication including posterior capsular rupture, anterior vitrectomy, and zonulysis as well as the site of IOL implantation were documented and post-operative complications including raised IOP, anterior chamber inflammation, visual axis opacity, posterior synechiae, subluxation of IOL, and IOL pigment deposition were listed.ResultsBest-corrected visual acuity 6 months after surgery was not different between the two groups. Also in early cataract surgery group, the rate of posterior capsular rupture was not significantly higher than the late surgery group (P=0.069). On the other hand, zonulysis was significantly higher in the late procedure group (P=0.039). Other complications including anterior vitrectomy, raised IOP, anterior chamber inflammation, visual axis opacity, posterior synechiae, subluxation of IOL, and IOL pigment deposition were not different in the two groups.ConclusionsEarly and late traumatic cataract surgery and IOL implantation after open globe injuries, have no significant difference regarding the post-surgical BCVA and prominent intraoperative and post-operative complications.

  4. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    OpenAIRE

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, ...

  5. Opacity

    CERN Document Server

    Huebner, Walter F

    2014-01-01

    The interaction of radiation with matter is a fundamental process in the universe; in particular, the absorption and scattering of radiation by matter (the opacity) govern the formation, evolution, and structure of stars and planets.  But opacity is also important in many terrestrial applications in which radiation is the dominant means of energy transfer, such as controlled nuclear-fusion, laser ablation, atmospheric entry and reentry, and the "greenhouse" effect.  This book covers all aspects of opacity and equations of state for plasmas, gases, vapors, and dust and emphasizes the continuous transformation of phases and molecular compositions with changing density and temperature under conditions of local thermodynamic equilibrium (LTE) while preserving the basic abundances of the chemical elements in a mixture.

  6. Microplasma Induced Cell Morphological Changes and Apoptosis of Ex Vivo Cultured Human Anterior Lens Epithelial Cells - Relevance to Capsular Opacification.

    Directory of Open Access Journals (Sweden)

    Nina Recek

    Full Text Available Inducing selective or targeted cell apoptosis without affecting large number of neighbouring cells remains a challenge. A plausible method for treatment of posterior capsular opacification (PCO due to remaining lens epithelial cells (LECs by reactive chemistry induced by localized single electrode microplasma discharge at top of a needle-like glass electrode with spot size ~3 μm is hereby presented. The focused and highly-localized atmospheric pressure microplasma jet with electrode discharge could induce a dose-dependent apoptosis in selected and targeted individual LECs, which could be confirmed by real-time monitoring of the morphological and structural changes at cellular level. Direct cell treatment with microplasma inside the medium appeared more effective in inducing apoptosis (caspase 8 positivity and DNA fragmentation at a highly targeted cell level compared to treatment on top of the medium (indirect treatment. Our results show that single cell specific micropipette plasma can be used to selectively induce demise in LECs which remain in the capsular bag after cataract surgery and thus prevent their migration (CXCR4 positivity to the posterior lens capsule and PCO formation.

  7. Primary iris claw IOL retrofixation with intravitreal triamcinolone acetonide in cases of inadequate capsular support.

    Science.gov (United States)

    Kelkar, Aditya; Shah, Rachana; Vasavda, Viraj; Kelkar, Jai; Kelkar, Shreekant

    2018-02-01

    To assess the outcomes and analyze complication rates following primary iris claw IOL retrofixation with intravitreal triamcinolone acetonide. This is a retrospective interventional case series. Patients with poor capsular support-diagnosed preoperatively or owing to intraoperative complications-were treated with iris claw IOL retrofixation with intravitreal triamcinolone acetonide. The data were retrospectively analyzed. 104 eyes of 102 patients with poor capsular support who underwent the procedure between 2010 and 2013 were analyzed. The minimum follow-up period was 12 months (ranging from 12 to 36 months). Iris claw IOL was implanted in-traumatic subluxated cataracts-24 cases (23.07%), non-traumatic subluxated cataracts in 16 cases (15.38%), or as a complication of cataract surgery-intraoperative posterior capsular rent in 48 cases (46.15%) and intraoperative nucleus drop in 16 cases (15.38%). The final mean best-corrected logMAR visual acuity improved from 1.36 ± 0.64 preoperatively to 0.36 ± 0.32 at 1-year follow-up. Complications included pupil ovalization in 11 cases (10.57%), transient elevation in intraocular pressure in 7 eyes (6.73%), postoperative hypotony in 5 eyes (4.80%), cystoid macular edema in 2 eyes (1.92%), retinal detachment in 1 eye (0.96%), vitreous hemorrhage in 1 eye (0.96%), and hyphema in 1 eye (0.96%). Primary iris claw IOL retrofixation provided excellent alternative in patients with inadequate capsular support. The visual outcomes were good along with favorable rates of complications. The addition of triamcinolone acetonide helps in reducing the chances of cystoid macular edema.

  8. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    OpenAIRE

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    Purpose : To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior ...

  9. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    Science.gov (United States)

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  10. Whiplash causes increased laxity of cervical capsular ligament

    Science.gov (United States)

    Ivancic, Paul C.; Ito, Shigeki; Tominaga, Yasuhiro; Rubin, Wolfgang; Coe, Marcus P.; Ndu, Anthony B.; Carlson, Erik J.; Panjabi, Manohar M.

    2009-01-01

    Background Previous clinical studies have identified the cervical facet joint, including the capsular ligaments, as sources of pain in whiplash patients. The goal of this study was to determine whether whiplash caused increased capsular ligament laxity by applying quasi-static loading to whiplash-exposed and control capsular ligaments. Methods A total of 66 capsular ligament specimens (C2/3 to C7/T1) were prepared from 12 cervical spines (6 whiplash-exposed and 6 control). The whiplash-exposed spines had been previously rear impacted at a maximum peak T1 horizontal acceleration of 8 g. Capsular ligaments were elongated at 1 mm/s in increments of 0.05 mm until a tensile force of 5 N was achieved and subsequently returned to neutral position. Four pre-conditioning cycles were performed and data from the load phase of the fifth cycle were used for subsequent analyses. Ligament elongation was computed at tensile forces of 0, 0.25, 0.5, 0.75, 1.0, 2.5, and 5.0 N. Two factor, non-repeated measures ANOVA (Pwhiplash-exposed and control groups and between spinal levels. Findings Average elongation of the whiplash-exposed capsular ligaments was significantly greater than that of the control ligaments at tensile forces of 0 and 5 N. No significant differences between spinal levels were observed. Interpretation Capsular ligament injuries, in the form of increased laxity, may be one component perpetuating chronic pain and clinical instability in whiplash patients. PMID:17959284

  11. Whiplash causes increased laxity of cervical capsular ligament.

    Science.gov (United States)

    Ivancic, Paul C; Ito, Shigeki; Tominaga, Yasuhiro; Rubin, Wolfgang; Coe, Marcus P; Ndu, Anthony B; Carlson, Erik J; Panjabi, Manohar M

    2008-02-01

    Previous clinical studies have identified the cervical facet joint, including the capsular ligaments, as sources of pain in whiplash patients. The goal of this study was to determine whether whiplash caused increased capsular ligament laxity by applying quasi-static loading to whiplash-exposed and control capsular ligaments. A total of 66 capsular ligament specimens (C2/3 to C7/T1) were prepared from 12 cervical spines (6 whiplash-exposed and 6 control). The whiplash-exposed spines had been previously rear impacted at a maximum peak T1 horizontal acceleration of 8 g. Capsular ligaments were elongated at 1mm/s in increments of 0.05 mm until a tensile force of 5 N was achieved and subsequently returned to neutral position. Four pre-conditioning cycles were performed and data from the load phase of the fifth cycle were used for subsequent analyses. Ligament elongation was computed at tensile forces of 0, 0.25, 0.5, 0.75, 1.0, 2.5, and 5.0 N. Two factor, non-repeated measures ANOVA (Pwhiplash-exposed and control groups and between spinal levels. Average elongation of the whiplash-exposed capsular ligaments was significantly greater than that of the control ligaments at tensile forces of 0 and 5 N. No significant differences between spinal levels were observed. Capsular ligament injuries, in the form of increased laxity, may be one component perpetuating chronic pain and clinical instability in whiplash patients.

  12. [Iris hooks and modified capsular tension ring for subluxation lens in patients with Marfan's syndrome].

    Science.gov (United States)

    Wu, Wen-Jie; Zheng, Dan-ying; Zheng, Ying-feng; Cai, Xiao-yu

    2007-02-01

    To evaluate clinical efficiency and safety of the iris hooks and modified capsular tension ring (MCTR) for the treatment of subluxation lens in patients with Marfan's syndrome. This study comprised 5 patients (7 eyes) with Marfan's syndrome and subluxation lens. After 3.2 mm clear cornea incision and continuous curvilinear capsulorhexis (CCC), 2 - 4 disposable nylon iris hooks were inserted through the stab incisions and placed in the capsulorhexis to support the capsule and enlarged the CCC. Following irrigation/aspiration, a MCTR with suture in its eyelet was placed in the capsule bag. After tightening and tying the suture of MCTR, the capsular bag was centered and fixed. A foldable AcrySof one-piece intraocular lens (IOL) was then placed in the capsule bag. Twelve months after the operation, the best corrected visual acuity was >/= 0.8 in six eyes and 0.7 in one eye. The scheimpflug images obtained from the Pentacam demonstrated that the IOL were well centered. UBM showed that all the MCTR and the haptics of the IOL were in the capsule bag, the eyelet of the MCTR was rested stably between the capsulorhexis margin and the iris. The retroillumination photograph indicated that only one eye had obvious posterior capsular opacification. No intraoperative and postoperative complications such as prolapse of vitreous and retina detachment was occurred. The iris hooks can provide excellent intraoperative capsule-lens stability and facilitate the manipulation during operation. MCTR allows additional suture fixation to the eye wall without damaging the capsular bag and maintains the long-term stability of the intraocular lens. Furthermore, MCTR is helpful for avoiding dislocation of the IOL due to progressive weakening of the zonular fibers in some patients and provides long-term safety.

  13. Lanthanide/Actinide Opacities

    Science.gov (United States)

    Hungerford, Aimee; Fontes, Christopher J.

    2018-06-01

    Gravitational wave observations benefit from accompanying electromagnetic signals in order to accurately determine the sky positions of the sources. The ejecta of neutron star mergers are expected to produce such electromagnetic transients, called macronovae (e.g. the recent and unprecedented observation of GW170817). Characteristics of the ejecta include large velocity gradients and the presence of heavy r-process elements, which pose significant challenges to the accurate calculation of radiative opacities and radiation transport. Opacities include a dense forest of bound-bound features arising from near-neutral lanthanide and actinide elements. Here we present an overview of current theoretical opacity determinations that are used by neutron star merger light curve modelers. We will touch on atomic physics and plasma modeling codes that are used to generate these opacities, as well as the limited body of laboratory experiments that may serve as points of validation for these complex atomic physics calculations.

  14. Heat transfer performance of the OPAC 106 heat exchanger; Warmte-overdrachtsprestaties van de OPAC106 warmtewisselaar

    Energy Technology Data Exchange (ETDEWEB)

    De Zwart, H.F.; Janssen, H.J.J. [Wageningen UR Glastuinbouw, Wageningen (Netherlands)

    2010-10-15

    The heat transfer performance of a new type compact heat exchanger were studied. It concerns the OPAC106, developed for the horticultural sector. The OPAC 106 combines a compact size with high heat transfer at low consumption of electricity for air circulation. OPAC stands for Oval Pipe Air Conditioner [Dutch] De warmte-overdrachtprestaties van een nieuw type compacte warmtewisselaar zijn bestudeerd. Het betreft de OPAC106, een speciaal voor de tuinbouw ontwikkelde warmtewisselaar. OPAC betekent Ovale Pijpen Air Conditioner.

  15. Astrophysical opacity library

    International Nuclear Information System (INIS)

    Huebner, W.F.; Merts, A.L.; Magee, N.H. Jr.; Argo, M.F.

    1977-08-01

    The astrophysical elements opacity library includes equation of state data, various mean opacities, and 2000 values of the frequency-dependent extinction coefficients in equally spaced intervals u identical with hν/kT from 0 to 20 for 41 degeneracy parameters eta from -28 (nondegenerate) to 500 and 46 temperatures kT from 1 eV to 100 keV. Among available auxiliary quantities are the free electron density, mass density, and plasma cutoff frequency. A library-associated program can produce opacities for mixtures with up to 20 astrophysically abundant constituent elements at 4 levels of utility for the user

  16. Comparative analysis of anterior and posterior contrast injection approaches for shoulder MR arthrograms in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Gupton, Theodore B.; Cahill, Anne M. [The Children' s Hospital of Philadelphia, Division of Interventional Radiology, Department of Radiology, Philadelphia, PA (United States); Delgado, Jorge [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Jaramillo, Diego [Stanford University Medical Center, Diagnostic Radiology, Palo Alto, CA (United States); Chauvin, Nancy A. [The Children' s Hospital of Philadelphia, Perelman School of Medicine at the University of Pennsylvania, Musculoskeletal Imaging, Department of Radiology, Philadelphia, PA (United States)

    2016-12-15

    There is no consensus in the literature concerning the optimal approach for performing a fluoroscopically guided shoulder arthrogram injection in a pediatric population. To compare adequacy of capsular injection and radiation doses between fluoroscopically guided anterior and posterior glenohumeral joint contrast injections in adolescents. We evaluated imaging in 67 adolescents (39 boys, 28 girls; mean age 16.0 years; range 11.7-19.1 years) who underwent an anterior approach glenohumeral contrast injection with subsequent MR imaging, and 67 age- and gender-matched subjects (39 boys, 28 girls; mean age 16.0 years; range 11.1-19.2 years) who underwent a posterior approach injection during the period June 2010 to September 2015. Two pediatric radiologists independently evaluated all MR shoulder arthrograms to assess adequacy of capsular distention and degree of contrast extravasation. We recorded total fluoroscopic time, dose-area product (DAP) and cumulative air kerma (CAK). There were no significant differences in age, gender, height, weight or body mass index between the populations (P-values > 0.6). The amount of contrast extravasation between the groups was not significantly different (P = 0.27). Three anterior injections (4.5%) and one posterior (1.5%) were suboptimal (P = 0.62). Fluoroscopy time was not different: 1.1 min anterior and 1.3 min posterior (P = 0.14). There was a significant difference in CAK (0.7 mGy anterior and 1.1 mGy posterior; P = 0.007) and DAP (5.3 μGym{sup 2} anterior and 9.4 μGym{sup 2} posterior; P = 0.008). Inter-rater agreement was excellent (Cohen kappa >0.81). Both techniques were technically successful. There was no difference in the fluoroscopy time for either approach. The radiation dose was higher with the posterior approach but this is of questionable clinical significance. (orig.)

  17. Síndrome de distensión del saco capsular: Presentación de un caso Capsular bag distension syndrome: A case presentation

    Directory of Open Access Journals (Sweden)

    Belmary Aragonés Cruz

    2006-12-01

    Full Text Available La capsulorrexis es el método preferido para la realización de la capsulotomía anterior. El síndrome de distensión del saco capsular es una complicación posoperatoria poco frecuente asociada a esta técnica. En este artículo presentamos un caso clínico de una mujer de 70 años, que presentaba una catarata nuclear dura en ojo izquierdo, a la cual se le realizó cirugía extracapsular técnica de Mini Nuc de Blumenthal, con capsulorrexis anterior e implante de LIO de Polimetil Metacrilato en cápsula posterior. Un mes más tarde la paciente acude con disminución de la visión, con sobrerrefracción miópica postoperatoria y desplazamiento anterior del lente. Se realizó capsulotomía anterior periférica con láser Nd YAG que resolvió la complicación, con recuperación de la profundidad de la cámara anterior y reposicionamiento del lente. La capsulotomía anterior periférica con láser es la mejor opción terapéutica, al ser inocua, de rápida recuperación, excelentes resultados visuales y mínimas complicacionesCapsulorrhexis is the preferred method to perform anterior capsulotomy. Capsular bag distension syndrome is one of the less frequent postoperative complications associated to this technique. This article prresented the clinical case of a 70-years-old woman who presented with hard nuclear cataract in hter left eye and underwent an extracapsular surgery by Mini Nuc technique, with anterior capsulorrhexis and polymethyl-metacrylate IoL implant in posterior capsule. A month after surgery, the patient went to the doctor´s with reduced vision, posoperative myopic overrefraction and anterior displacement of the lens. Then, peripheral anterior capsulotomy with Nd YAG laser was used to overcome this problem; anterior chamber depth and repositioning of the lens were recovered. Peripheral anterior capsulotomy with laser is the best therapeutic choice since it is harmless, and offers rapid recovery, excellent visual results and minimal

  18. Some investigations about the Carson opacities

    International Nuclear Information System (INIS)

    Cox, A.N.; Kidman, R.B.

    1983-01-01

    Accurate opacities for stellar composition mixtures are needed for all studies of stellar structure, evolution, stability, and pulsation. Three problem areas where increased opacities would be welcome are: the observed broadening of the upper main sequence that can be produced with larger opacities that tend to expand the stars; the existence of the double-mode Cepheids and their anomalously low period ratios which can be predicted to be lower, as observed, if opacities are larger; and the small sensitivity of the low mass population II horizontal branch luminosity to the metal content of their compositions that would be more effective if their opacity were increased. Several other problems that could be solved by larger opacities have been widely discussed, but we feel that they are not justifiably an opacity problem. The conclusion of our considerations are that the Thomas-Fermi method for getting opacities used by Carson and his collaborators does not produce values appreciably different from those obtained without this method at Los Alamos, and that these persistent astrophysical problems must be solved in other ways. We here propose a possible error in the Carson opacities, and, further, we mention another that seems to be the correct reconciliation between these two opacity sets

  19. Asset Opacity and Liquidity

    OpenAIRE

    Stenzel, A.; Wagner, W.B.

    2013-01-01

    Abstract: We consider a model of private information acquisition in which the cost of information depends on an asset's opacity. The model generates a hump-shaped relationship between opacity and the equilibrium amount of private information. In particular, the incentives to acquire information are largest for assets of intermediate opacity; such assets hence display low liquidity in the secondary market due to adverse selection. We also show that costly information acquisition generates ince...

  20. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W. Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter

  1. Thus Spake the OPAC User.

    Science.gov (United States)

    Markey, Karen

    1983-01-01

    Findings of focused-group interviews conducted for OCLC study of library users and online public access catalogs (OPACs) indicate users like OPACs, have problems finding right subject heading, envision features to improve subject access, want access to more than books, and want OPACs to provide new services. Eight references are listed. (EJS)

  2. Capsular Polysaccharide Expression in Commensal Streptococcus Species

    DEFF Research Database (Denmark)

    Skov Sørensen, Uffe B; Yao, Kaihu; Yang, Yonghong

    2016-01-01

    Expression of a capsular polysaccharide is considered a hallmark of most invasive species of bacteria, including Streptococcus pneumoniae, in which the capsule is among the principal virulence factors and is the basis for successful vaccines. Consequently, it was previously assumed that capsule....... pneumoniae evolved by import of cps fragments from commensal Streptococcus species, resulting in a mosaic of genes of different origins. The demonstrated antigenic identity of at least eight of the numerous capsular polysaccharide structures expressed by commensal streptococci with recognized serotypes of S...... of Streptococcus pneumoniae and is the basis for successful vaccines against infections caused by this important pathogen. Contrasting with previous assumptions, this study showed that expression of capsular polysaccharides by the same genetic mechanisms is a general property of closely related species...

  3. Helioseismic Tests of Radiative Opacities.

    Energy Technology Data Exchange (ETDEWEB)

    Guzik, J. A. (Joyce Ann); Neuforge, C. M. (Corinne M.); Keady, J. J.; Magee, N. H. (Norman H.); Bradley, P. A. (Paul A.)

    2002-01-01

    During the past fifteen years, thousands of solar acoustic oscillation modes have been measured to remarkable precision, in many cases to within 0.01%. These frequencies have been used to infer the interior structure of the sun and test the physical input to solar models. Here we summarize the procedures, input physics and assumptions for calculating a standard solar evolution model. We compare the observed and calculated sound speed profile and oscillation frequencies of solar models calibrated using the new Los Alamos LEDCOP and Livermore OPAL Rosseland mean opacities for the same element mixture. We show that solar oscillations are extremely sensitive to opacities, with opacity differences of only a few percent producing an easily detectable effect on the sound speed and predicted frequencies. The oscillation data indicate that agreement would be improved by an opacity increase of several percent below the convection zone for both the LEDCOP and OPAL opacities.

  4. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  5. Virulence of six capsular serotypes of Porphyromonas gingivalis in a mouse model

    NARCIS (Netherlands)

    Laine, ML; van Winkelhoff, AJ

    1998-01-01

    Capsular structures of Porphyromonas gingivalis have been correlated to the pathogenicity in animal models. Six polysaccharide capsular serotypes have recently been described in P. gingivalis. In the present study, virulence of the P. gingivalis strains of the six capsular serotypes was compared

  6. Asset Opacity and Liquidity

    NARCIS (Netherlands)

    Stenzel, A.; Wagner, W.B.

    2013-01-01

    Abstract: We consider a model of private information acquisition in which the cost of information depends on an asset's opacity. The model generates a hump-shaped relationship between opacity and the equilibrium amount of private information. In particular, the incentives to acquire information are

  7. Changes in lens stiffness due to capsular opacification in accommodative lens refilling

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Sharma, Prashant K.; van Kooten, Theo G.; Koopmans, Steven A.

    Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been

  8. Recent progress on astrophysical opacity

    International Nuclear Information System (INIS)

    Rogers, F.J.; Iglesias, C.A.

    1992-08-01

    Improvements in the calculation of the opacity of astrophysical plasmas has helped to resolve several long-standing puzzles in the modeling of variable stars. The most significant opacity enhancements over the Los Alamos Astrophysical Library (LAOL) are due to improvements in the equation of state and atomic physics. Comparison with experiment has corroborated the predicted large opacity increases due to transitions in M-shell iron. We give a summary of recent developments

  9. [Capsular retensioning in anterior unidirectional glenohumeral instability].

    Science.gov (United States)

    Benítez Pozos, Leonel; Martínez Molina, Oscar; Castañeda Landa, Ezequiel

    2007-01-01

    To present the experience of the Orthopedics Service PEMEX South Central Hospital in the management of anterior unidirectional shoulder instability with an arthroscopic technique consisting of capsular retensioning either combined with other anatomical repair procedures or alone. Thirty-one patients with anterior unidirectional shoulder instability operated-on between January 1999 and December 2005 were included. Fourteen patients underwent capsular retensioning and radiofrequency, and in 17 patients, capsular retensioning was combined with suture anchors. Patients with a history of relapsing glenohumeral dislocations and subluxations, with anterior instability with or without associated Bankart lesions were selected; all of them were young. The results were assessed considering basically the occurrence of instability during the postoperative follow-up. No cases of recurring instability occurred. Two cases had neuroma and one experienced irritation of the suture site. Six patients had residual limitation of combined lateral rotation and abduction movements, of a mean of 10 degrees compared with the healthy contralateral side. The most frequent incident was the leak of solutions to the soft tissues. Capsular retensioning, whether combined or not with other anatomical repair techniques, has proven to result in a highly satisfactory rate of glenohumeral stabilization in cases of anterior unidirectional instabilities. The arthroscopic approach offers the well-known advantages of causing less damage to the soft tissues, and a shorter time to starting rehabilitation therapy and exercises.

  10. LINE BROADENING AND THE SOLAR OPACITY PROBLEM

    Energy Technology Data Exchange (ETDEWEB)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il [The Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel)

    2016-06-20

    The calculation of line widths constitutes theoretical and computational challenges in the calculation of opacities of hot, dense plasmas. Opacity models use line broadening approximations that are untested at stellar interior conditions. Moreover, calculations of atomic spectra of the Sun indicate a large discrepancy in the K-shell line widths between several atomic codes and the Opacity-Project (OP). In this work, the atomic code STAR is used to study the sensitivity of solar opacities to line broadening. Variations in the solar opacity profile due to an increase of the Stark widths resulting from discrepancies with OP, are compared, in light of the solar opacity problem, with the required opacity variations of the present day Sun, as imposed by helioseismic and neutrino observations. The resulting variation profile is much larger than the discrepancy between different atomic codes, agrees qualitatively with the missing opacity profile, recovers about half of the missing opacity nearby the convection boundary, and has a little effect in the internal regions. Since it is hard to estimate quantitatively the uncertainty in the Stark widths, we show that an increase of all line widths by a factor of about ∼100 recovers quantitatively the missing opacity. These results emphasize the possibility that photoexcitation processes are not modeled properly, and more specifically, highlight the need for a better theoretical characterization of the line broadening phenomena at stellar interior conditions, and of the uncertainty due to the way it is implemented by atomic codes.

  11. Neisseria meningitidis serogroup A capsular polysaccharide acetyltransferase, methods and compositions

    Energy Technology Data Exchange (ETDEWEB)

    Stephens, David S [Stone Mountain, GA; Gudlavalleti, Seshu K [Kensington, MD; Tzeng, Yih-Ling [Atlanta, GA; Datta, Anup K [San Diego, CA; Carlson, Russell W [Athens, GA

    2011-02-08

    Provided are methods for recombinant production of an O-acetyltransferase and methods for acetylating capsular polysaccharides, especially those of a Serogroup A Neisseria meningitidis using the recombinant O-acetyltransferase, and immunogenic compositions comprising the acetylated capsular polysaccharide.

  12. Design, characterization, and in vitro cellular inhibition and uptake of optimized genistein-loaded NLC for the prevention of posterior capsular opacification using response surface methodology.

    Science.gov (United States)

    Zhang, Wenji; Li, Xuedong; Ye, Tiantian; Chen, Fen; Sun, Xiao; Kong, Jun; Yang, Xinggang; Pan, Weisan; Li, Sanming

    2013-09-15

    This study was to design an innovative nanostructured lipid carrier (NLC) for drug delivery of genistein applied after cataract surgery for the prevention of posterior capsular opacification. NLC loaded with genistein (GEN-NLC) was produced with Compritol 888 ATO, Gelucire 44/14 and Miglyol 812N, stabilized by Solutol(®) HS15 by melt emulsification method. A 2(4) central composite design of 4 independent variables was performed for optimization. Effects of drug concentration, Gelucire 44/14 concentration in total solid lipid, liquid lipid concentration, and surfactant concentration on the mean particle size, polydispersity index, zeta potential and encapsulation efficiency were investigated. Analysis of variance (ANOVA) statistical test was used to assess the optimization. The optimized GEN-NLC showed a homogeneous particle size of 90.16 nm (with PI=0.33) of negatively charged surface (-25.08 mv) and high encapsulation efficiency (91.14%). Particle morphology assessed by TEM revealed a spherical shape. DSC analyses confirmed that GEN was mostly entrapped in amorphous state. In vitro release experiments indicated a prolonged and controlled genistein release for 72 h. In vitro growth inhibition assay showed an effective growth inhibition of GEN-NLCs on human lens epithelial cells (HLECs). Preliminary cellular uptake test proved a enhanced penetration of genistein into HLECs when delivered in NLC. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. [Surgical solutions to luxation of the IOL--capsular bag--capsular tension ring complex].

    Science.gov (United States)

    Berthout, A; Turut, P; Taboureau, E; Denimal, F; Milazzo, S

    2007-02-01

    The spontaneous luxation of the intraocular lens-capsular bag-capsular tension ring complex is a serious but fortunately rare complication. The authors report a combined surgical procedure to reposition the complex in a patient who was operated on for bilateral lens subluxation 4 years before and whose enophthalmia made surgery difficult. Two surgical techniques can be considered to reposition the complex and avoid explantation. The McCannel modified stitch can capture the complex with the help of a transcorneal point and then a transscleral suture on the 12 o'clock meridian, despite the enophthalmia of the patient; the Moreno transscleral stitch. Both techniques suture the complex to the ciliary sulcus. Moreno's technique is easy and safe for the endothelium and must therefore be attempted first. In case of failure, the McCannel modified stitch remains a useful and satisfying procedure allowing transscleral fixation of the complex to the sulcus at the cost of a minimal corneal trauma.

  14. Management of the failed posterior/multidirectional instability patient.

    Science.gov (United States)

    Forsythe, Brian; Ghodadra, Neil; Romeo, Anthony A; Provencher, Matthew T

    2010-09-01

    Although the results of operative treatment of posterior and multidirectional instability (P-MDI) of the shoulder have improved, they are not as reliable as those treated for anterior instability of the shoulder. This may be attributed to the complexities in the classification, etiology, and physical examination of a patient with suspected posterior and multidirectional instability. Failure to address the primary and concurrent lesion adequately and the development of pain and/or stiffness are contributing factors to the failure of P-MDI procedures. Other pitfalls include errors in history and physical examination, failure to recognize concomitant pathology, and problems with the surgical technique or implant failure. Patulous capsular tissues and glenoid version also play in role management of failed P-MDI patients. With an improved understanding of pertinent clinical complaints and physical examination findings and the advent of arthroscopic techniques and improved implants, successful strategies for the nonoperative and operative management of the patient after a failed posterior or multidirectional instability surgery may be elucidated. This article highlights the common presentation, physical findings, and radiographic workup in a patient that presents after a failed P-MDI repair and offers strategies for revision surgical repair.

  15. Detailed Opacity Calculations for Astrophysical Applications

    Directory of Open Access Journals (Sweden)

    Jean-Christophe Pain

    2017-05-01

    Full Text Available Nowadays, several opacity codes are able to provide data for stellar structure models, but the computed opacities may show significant differences. In this work, we present state-of-the-art precise spectral opacity calculations, illustrated by stellar applications. The essential role of laboratory experiments to check the quality of the computed data is underlined. We review some X-ray and XUV laser and Z-pinch photo-absorption measurements as well as X-ray emission spectroscopy experiments involving hot dense plasmas produced by ultra-high-intensity laser irradiation. The measured spectra are systematically compared with the fine-structure opacity code SCO-RCG. The focus is on iron, due to its crucial role in understanding asteroseismic observations of β Cephei-type and Slowly Pulsating B stars, as well as of the Sun. For instance, in β Cephei-type stars, the iron-group opacity peak excites acoustic modes through the “kappa-mechanism”. Particular attention is paid to the higher-than-predicted iron opacity measured at the Sandia Z-machine at solar interior conditions. We discuss some theoretical aspects such as density effects, photo-ionization, autoionization or the “filling-the-gap” effect of highly excited states.

  16. Multicentre study on capsular closure versus non-capsular closure during hip arthroscopy in Danish patients with femoroacetabular impingement (FAI)

    DEFF Research Database (Denmark)

    Dippmann, Christian; Kraemer, Otto; Lund, Bent

    2018-01-01

    in patients without additional risk factors for instability such as hypermobility or dysplasia of the hip. We hypothesised that capsular closure will lead to a superior outcome in hip arthroscopy for femoroacetabular impingement syndrome (FAIS) compared with non-capsular closure. METHODS AND ANALYSIS...... years and FAIS according to the Warwick agreement. Exclusion criteria are: previous hip surgery in either hip, previous conditions of Legg-Calvé-Perthes or slipped capital femoral epiphysis, malignant disease, recent hip or pelvic fractures, arthritis, Ehlers-Danlos or Marfan disease, recent (within 6...

  17. Radiological landmarks for the safe extra-capsular placement of supra-acetabular half pins for external fixation.

    Science.gov (United States)

    Lidder, Surjit; Heidari, Nima; Gänsslen, Axel; Grechenig, Wolfgang

    2013-03-01

    Low anterior external fixators are constructed by placing half pins in the dense bone tunnel of the supra-acetabular region in an anterior to posterior direction. Although the placement of these pins is extra-articular, they may still breach the hip capsule on the anterior inferior iliac spine and thus be intra-capsular. We aim to provide radiological markers for the most superior fibres of the capsule to allow safe extra-capsular pin placement within the supra-acetabular bone tunnel. Thirteen cadaveric pelves were used for this study. The supra-acetabular bone tunnel was visualised with an image intensifier. The proximal most fibres of the hip joint capsule were marked with a K-wire so that their relation to the bone tunnel could be clearly seen on the images. Once all images were acquired they were calibrated and analysed to estimate the dimensions of the supra-acetabular bone tunnel and the reflection of the hip capsule. The median height of the bone tunnel was 23.6 mm (18.9-33.2) and maximum width was 11.4 mm (7.6-16.3). The inferior margin of the bone tunnel was 6.7 mm (1.1-14.5) superior to the acetabular dome, and the most proximal fibres of the capsule were 9.3 mm (4.7-6.1) superior to the acetabular dome. The inferior portion of the tunnel was 3.7 mm (0.3-8.9) within the joint. Half pins for the construction of a pelvic external fixator should be placed in the upper half of the supra-acetabular bone corridor to minimise the risk of intra-capsular placement.

  18. Roentgenologic diagnostics of capsular ligament lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, C.J.; Jaeger, M.

    1981-10-01

    The X-ray diagnostic is of obvious importance and relevance in the detection of acute or old capsular ligament lesions of the limb joint. On the one hand it serves as the plain radiograph (roentgenogram without contrast medium) for the assessment of osseous secondary lesions, for the documentation of luxationary positions of the joint partners, and in old capsular ligament lesions for the detection of an already existing arthrosis. On the other hand the X-ray images are of main importance, which are made from the hand-held limb in order to permit a comparison of the two sides, and which beyond the clinical detection of a joint instability indicate the extent and the direction of this instability and which also document it, and which allow in adolescents to recognize a separation of the epiphysis as an alternative to the capsular ligament rupture. Only in particular cases arthrography can provide some additional information, so for example in the case of an isolated syndesmosis rupture, ruptures of the rosette of the rotator muscle or of a damaged triangular disk in the hand. Angiography is only required in cases of traumatic luxations of the knee in order to exclude an intimal lesion of the popliteal artery.

  19. Deep neural network convolution (NNC) for three-class classification of diffuse lung disease opacities in high-resolution CT (HRCT): consolidation, ground-glass opacity (GGO), and normal opacity

    Science.gov (United States)

    Hashimoto, Noriaki; Suzuki, Kenji; Liu, Junchi; Hirano, Yasushi; MacMahon, Heber; Kido, Shoji

    2018-02-01

    Consolidation and ground-glass opacity (GGO) are two major types of opacities associated with diffuse lung diseases. Accurate detection and classification of such opacities are crucially important in the diagnosis of lung diseases, but the process is subjective, and suffers from interobserver variability. Our study purpose was to develop a deep neural network convolution (NNC) system for distinguishing among consolidation, GGO, and normal lung tissue in high-resolution CT (HRCT). We developed ensemble of two deep NNC models, each of which was composed of neural network regression (NNR) with an input layer, a convolution layer, a fully-connected hidden layer, and a fully-connected output layer followed by a thresholding layer. The output layer of each NNC provided a map for the likelihood of being each corresponding lung opacity of interest. The two NNC models in the ensemble were connected in a class-selection layer. We trained our NNC ensemble with pairs of input 2D axial slices and "teaching" probability maps for the corresponding lung opacity, which were obtained by combining three radiologists' annotations. We randomly selected 10 and 40 slices from HRCT scans of 172 patients for each class as a training and test set, respectively. Our NNC ensemble achieved an area under the receiver-operating-characteristic (ROC) curve (AUC) of 0.981 and 0.958 in distinction of consolidation and GGO, respectively, from normal opacity, yielding a classification accuracy of 93.3% among 3 classes. Thus, our deep-NNC-based system for classifying diffuse lung diseases achieved high accuracies for classification of consolidation, GGO, and normal opacity.

  20. Analysis of hepatic capsular enhancement mimicking the Fitz-hugh-curtis syndrome on a multidetector computed tomography

    International Nuclear Information System (INIS)

    Park, Ji Sang; Park, Seong Jin; Lee, Hae Kyung; Yi, Boem Ha; Hong, Hyun Sook; Cha, Jang Gyu; Lim, Hoon

    2008-01-01

    To determine the associated diseases causing hepatic capsular enhancement and analyze the relationship of the capsular enhancement patterns as a function of the associated diseases. We retrospectively reviewed 797 patients having undergone arterial phase abdominal CT scans. Among these images, 47 patients showed hepatic capsular enhancement (13 men and 34 women; mean age: 53.1; age range: 5-91 years). We investigated if there was a correlation between the pattern of hepatic capsular enhancement and cause of disease. When the hepatic capsular enhancement was found to persist until the portal phase, the symptom duration was evaluated. Hepatic capsular enhancements were presented in 5.9% (47/797) of the arterial phase abdominal CT scans. Six patients (12.8%) were diagnosed with Fitz-Hugh-Curtis syndrome. The other causes of hepatic capsular enhancement included 20 cases of inflammation, 13 cases of malignancy, and 8 cases of other diseases. The extent of the hepatic capsular enhancement was not significantly different among the causes of disease. In thirty two of 47 patients (68.1%), hepatic capsular enhancement persisted until the portal phase images. Hepatic capsular enhancement on an arterial phase is a nonspecific imaging finding observed in the Fitz-Hugh-Curtis syndrome as well as a variety of other diseases. A CT is useful in finding the hepatic capsular enhancement and determining the accompanying disease

  1. HELIOSEISMIC TESTS OF THE NEW LOS ALAMOS OPACITIES

    Energy Technology Data Exchange (ETDEWEB)

    J. GUZIK; ET AL

    2001-01-01

    We compare the helioseismic properties of two solar models, one calibrated with the OPAL opacities and the other with the recent Los Alamos LEDCOP opacities. We show that, in the radiative interior of the Sun, the small differences between the two sets of opacities (up to 6% near the base of the convection zone) lead to noticeable differences in the solar structure (up to 0.4% in sound speed), with the OPAL model being the closest to the helioseismic data. More than half of the difference between the two opacity sets results from the interpolation scheme and from the relatively widely spaced temperature grids used in the tables. The remaining 3% intrinsic difference between the OPAL and the LEDCOP opacities in the radiative interior of the Sun is well within the error bars on the opacity calculations resulting from the uncertainties on the physics. We conclude that the OPAL and LEDCOP opacity sets do about as well in the radiative interior of the Sun.

  2. Congenital cataract screening

    Directory of Open Access Journals (Sweden)

    Zhale Rajavi

    2016-01-01

    Full Text Available Congenital cataract is a leading cause of visual deprivation which can damage the developing visual system of a child; therefore early diagnosis, management and long-term follow-up are essential. It is recommended that all neonates be screened by red reflex examination at birth and suspected cases be referred to ophthalmic centers. Early surgery (1 year is highly recommended. After surgery, amblyopia treatment and periodic follow-up examinations should be started as soon as possible to achieve a satisfactory visual outcome. Practitioners should consider the possibility of posterior capsular opacity, elevated intraocular pressure and amblyopia during follow-up, especially in eyes with microphthalmia and/or associated congenital anomalies. All strabismic children should undergo slit lamp examination prior to strabismus surgery to rule out congenital lens opacities. From a social point of view, equal and fair medical care should be provided to all children regardless of gender.

  3. Web OPAC Interfaces: An Overview.

    Science.gov (United States)

    Babu, B. Ramesh; O'Brien, Ann

    2000-01-01

    Discussion of Web-based online public access catalogs (OPACs) focuses on a review of six Web OPAC interfaces in use in academic libraries in the United Kingdom. Presents a checklist and guidelines of important features and functions that are currently available, including search strategies, access points, display, links, and layout. (Author/LRW)

  4. SOLAR OPACITY CALCULATIONS USING THE SUPER-TRANSITION-ARRAY METHOD

    International Nuclear Information System (INIS)

    Krief, M.; Feigel, A.; Gazit, D.

    2016-01-01

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation–convection interface. STAR Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity

  5. SOLAR OPACITY CALCULATIONS USING THE SUPER-TRANSITION-ARRAY METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il [The Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel)

    2016-04-10

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation–convection interface. STAR Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity.

  6. Update on the opal opacity code

    International Nuclear Information System (INIS)

    Rogers, F.J.; Iglesias, C.A.; Wilson, B.G.

    1990-01-01

    Persisting discrepancies between theory and observation in a number of astrophysical properties has led to the conjecture that opacity databases may be inaccurate. The OPAL opacity code has been developed to address this question. The physical basis of OPAL removes several of the approximations present in past calculations. For example, it utilizes a much larger and more detailed set of atomic data than was used to construct the los Alamos Astrophysical Library. This data is generated online, in LS or intermediate coupling, from prefitted analytic effective potentials and is of similar quality as single configuration, relativistic, self-consistent-field calculations. The OPAL code has been used to calculate opacities for the solar core and for Cepheid variable stars. In both cases, significant increases in the opacity compared to the Los Alamos Astrophysical Library were found

  7. Restricted fish feeding reduces cod otolith opacity

    DEFF Research Database (Denmark)

    Høie, H.; Folkvord, A.; Mosegaard, Henrik

    2008-01-01

    The purpose of this work was to examine the effect of reduced feeding and constant temperature on cod otolith opacity. Three groups of juvenile cod were given restricted food rations at different times for 4 months, resulting in depressed somatic growth. Otolith opacity was measured on pictures...... in otolith opacity were found between individual fish both within groups and between groups. In two of the three groups significantly more translucent otolith material was deposited in response to reduced feeding. Our results show that variations in feeding and hence fish growth resulted in variation...... in otolith opacity, but the effect was minor compared to that of variations in ambient temperature. The combined influence of these effects, which both act on fish metabolism, are most likely controlling the seasonal opacity changes observed in wild fish. Our results help explain the variations seen in fish...

  8. Globular bodies: a primary cause of the opacity in senile and diabetic posterior cortical subcapsular cataracts?

    Science.gov (United States)

    Creighton, M O; Trevithick, J R; Mousa, G Y; Percy, D H; McKinna, A J; Dyson, C; Maisel, H; Bradley, R

    1978-07-01

    We examined 9 cataracts from maturity onset diabetics and 4 senile posterior subcapsular cataracts by scanning electron microscopy, transmission electron microscopy, immunofluorescence for crystallin proteins and actin, histochemical methods and x-ray diffraction. The cataractous regions contained spherical globules up to 20 mu in diameter, often in a fibrous matrix. Some were extracellular Morgagnian globules, apparently formed by blebbing from the cell surface; others appeared to have been formed intracellularly. The area of globular degeneration was usually 300 mu deep, but had deeper fusiform extensions. Morphological changes in the cell cytoplasm varied according to their depth in the cataract. Electron microscopy showed intracellular and extracellular globules, many of them were bounded by lipid bilayer membranes. Immunofluorescent staining showed that all the globules contained gamma-crystallin; some contained alpha- and beta-crystallins and actin. All the globules contained higher concentrations of cysteine or cystine than the surrounding lens tissue but they did not react to stains for carbohydrate or calcium. X-ray diffraction studies showed that crystalline calcium salts were absent. Globules and cavities averaged 45% of the total area in cross section. Assuming an area of cataract to be 300 micron thick and that globules 1 mu in diameter scattered, while 2--20 mu in diameter reflected light, we calculated that light passing through such a thickness would be reduced by 65%. Thus the globules could account for most of the opacity of the cataractous area. Presumably the fibrous degeneration of the cells causes enough light scattering to account for the remainder of the reduction. Cataract patients complain of decreased visual acuity, a golden halo around objects, and difficulties when driving while facing oncoming traffic at night. These probably result from light scattering. In our previous experiments, globular bodies containing gamma-crystallin were

  9. Extended Opacity Tables with Higher Temperature-Density-Frequency Resolution

    Science.gov (United States)

    Schillaci, Mark; Orban, Chris; Delahaye, Franck; Pinsonneault, Marc; Nahar, Sultana; Pradhan, Anil

    2015-05-01

    Theoretical models for plasma opacities underpin our understanding of radiation transport in many different astrophysical objects. These opacity models are also relevant to HEDP experiments such as ignition scale experiments on NIF. We present a significantly expanded set of opacity data from the widely utilized Opacity Project, and make these higher resolution data publicly available through OSU's portal with dropbox.com. This expanded data set is used to assess how accurate the interpolation of opacity data in temperature-density-frequency dimensions must be in order to adequately model the properties of most stellar types. These efforts are the beginning of a larger project to improve the theoretical opacity models in light of experimental results at the Sandia Z-pinch showing that the measured opacity of Iron disagrees strongly with all current models.

  10. Revitalizing the Library OPAC: Interface, Searching, and Display Challenges

    Directory of Open Access Journals (Sweden)

    Jia Mi

    2008-03-01

    Full Text Available The behavior of academic library users has drastically changed in recent years. Internet search engines have become the preferred tool over the library online public access catalog (OPAC for finding information. Libraries are losing ground to online search engines. In this paper, two aspects of OPAC use are studied: (1 the current OPAC interface and searching capabilities, and (2 the OPAC bibliographic display. The purpose of the study is to find answers to the following questions: Why is the current OPAC ineffective? What can libraries and librarians do to deliver an OPAC that is as good as search engines to better serve our users? Revitalizing the library OPAC is one of the pressing issues that has to be accomplished.

  11. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  12. Renal Capsular Leiomyoma: Report of a Case with Unusual CT Appearance

    International Nuclear Information System (INIS)

    Mak, C.W.; Chou, C.K.; Tzeng, W.S.

    2006-01-01

    Clinically symptomatic renal capsular leiomyomas are rare. Previous research has shown that these tumors are usually well-defined cystic lesions, solid lesions, or a mixture of the two. We report an unusual case of renal capsular leiomyoma which was well defined by ultrasonography, but lacked a well-defined edge in CT. The reason for the absence of a well-defined tumor edge is probably due to degeneration in certain parts of the tumor resulting in a different degree of enhancement. Thus, the possibility of renal capsular leiomyoma should be included in the differential diagnosis whenever a renal mass is found, especially when either CT or ultrasonography shows that the tumor has a smooth, well-defined contour

  13. Renal Capsular Leiomyoma: Report of a Case with Unusual CT Appearance

    Energy Technology Data Exchange (ETDEWEB)

    Mak, C.W.; Chou, C.K.; Tzeng, W.S. [Chi-Mei Medical Center, Yung-Kang Campus, Tainan, Taiwan (China). Dept. of Radiology

    2006-09-15

    Clinically symptomatic renal capsular leiomyomas are rare. Previous research has shown that these tumors are usually well-defined cystic lesions, solid lesions, or a mixture of the two. We report an unusual case of renal capsular leiomyoma which was well defined by ultrasonography, but lacked a well-defined edge in CT. The reason for the absence of a well-defined tumor edge is probably due to degeneration in certain parts of the tumor resulting in a different degree of enhancement. Thus, the possibility of renal capsular leiomyoma should be included in the differential diagnosis whenever a renal mass is found, especially when either CT or ultrasonography shows that the tumor has a smooth, well-defined contour.

  14. DETECTION OF PNEUMOCOCCAL CAPSULAR ANTIGEN IN THE PRESENCE OF PENICILLIN IN-VITRO

    NARCIS (Netherlands)

    HOLLOWAY, Y; BOERSMA, WG; KUTTSCHRUTTER, H; SNIJDER, JAM

    1993-01-01

    Eight strains of Streptococcus pneumoniae were tested in vitro for their ability to produce capsular antigen in the presence of penicillin. It was found that, provided 10(6) to 10(7) pneumococci/ml were present, capsular antigen could be detected during the 72 h in which the experiment was

  15. A case report of intraocular lens luxation with the capsular bag after vitrectomy.

    Science.gov (United States)

    Kawai, Kenji; Bando, Masayasu; Suzuki, Takahiro; Hayakawa, Kenji

    2004-04-01

    We experienced a case of intraocular lens (IOL) luxation with the capsular bag after vitrectomy. The case was a 66-year-old female in whom an IOL was implanted one year after surgery for giant tear retinal detachment using silicone oil. Four years after the implantation surgery, the patient suffered subluxation of the IOL with the capsular bag. Examinations of the luxated IOL with the capsular bag using a stereoscopic microscope confirmed the presence of silicone oil droplets between the capsule and the IOL. Adhesion of vitreous body residues was observed in the capsule. Luxation of the IOL was thought to be connected with chronic inflammation resulting from the use of silicone oil and repeated vitrectomy. In addition to examining pathological findings of luxated IOL, it would also be important in the future to identify the pathology of the capsular bag.

  16. Performance audit procedures for opacity monitors

    International Nuclear Information System (INIS)

    Plaisance, S.J.; Peeler, J.W.

    1987-04-01

    This manual contains monitor-specific performance audit procedures and data forms for use in conducting audits of installed opacity continuous emission monitoring systems (CEMS). General auditing procedures and acceptance limits for various audit criteria are discussed. Practical considerations and common problems encountered in conducting audits are delineated, and recommendations are included to optimize the successful completion of performance audits. Performance audit procedures and field-data forms were developed for six common opacity CEMS: (1) Lear Siegler, Inc. Model RM-41; (2) Lear Siegler, Inc. Model RM-4; (3) Dynatron Model 1100; (4) Thermo Electron, Inc. Model 400; (5) Thermo Electron, Inc. Model 1000A; and (6) Enviroplan Model D-R280 AV. Generic audit procedures are included for use in evaluating opacity CEMS with multiple transmissometers and combiner devices. In addition, several approaches for evaluating the zero-alignment or clear-path zero response are described. The zero-alignment procedures are included since the factor is fundamental to the accuracy of opacity monitoring data, even though the zero-alignment checks cannot usually be conducted during a performance audit

  17. CT features of malignant hepatic tumors : the significance of capsular retraction

    International Nuclear Information System (INIS)

    Seo, Bo Kyoung; Rhee, Ji Yong; Seol, Hae Young; Lee, Ki Yeol; Park, Cheol Min; Chung, Kyoo Byung

    1998-01-01

    To evaluate the prevalence of capsular retraction in malignant hepatic tumors and the factors involved. Between January 1994 and December 1996, we retrospectively reviewed the CT scans of 152 patients with pathologically-proven, peripherally-located, malignant hepatic tumors. We evaluated size, site, portal and hepatic venous obstruction, bile duct dilatation, and liver atrophy in 18 cases involving capsular retraction. The overall prevalence of capsular retraction among malignant hepatic tumors was 18/152 (12 %); the prevalence was 9/129 (7%) in hepatocellular carcinoma, 6/14 (43 %) in cholangiocarcinoma and 3/9 (33 %) in metastatic cancer; among cases of cholangiocarcinoma and metastatic cancer, the prevalence was high (p<0.05). Portal venous obstruction was seen in six patients with hepatocellular carcinoma ( a high incidence; p=0.04) and one with cholangiocarcinoma. Hepatic venous obstruction was demonstrated in one patient with hepatocellular carcinoma and one with cholangiocarcinoma. Among cholangiocarcinoma patients, bile duct obstruction was seen in four and liver atrophy in three, but among metastatic cancer cases there were no similar findings. The main factors causing capsular retraction were portal venous obstruction in hepatocellular carcinoma and bile duct obstruction and liver atrophy in cholangiocarcinoma. (author). 16 refs., 3 figs

  18. Capsular contracture and possible implant rupture: is magnetic resonance imaging useful?

    Science.gov (United States)

    Paetau, Alyssa A; McLaughlin, Sarah A; McNeil, Rebecca B; Sternberg, Erez; TerKonda, Sarvam P; Waldorf, James C; Perdikis, Galen

    2010-03-01

    Currently, magnetic resonance imaging is considered the accepted standard to evaluate breast implant integrity. To evaluate its utility in diagnosing ruptured silicone implants in the setting of capsular contracture and to correlate the preoperative assessment of implant integrity with or without magnetic resonance imaging with operative findings, 319 capsulectomies (171 patients with capsular contractures) were retrospectively reviewed. Preoperative magnetic resonance imaging was done on 160 implants, whereas the remaining 159 were evaluated using only physical examination and/or mammography. Postoperative results were analyzed to determine the sensitivity, specificity, and accuracy of preoperative magnetic resonance imaging in comparison with clinical and/or mammography evaluation alone. Although occasionally valuable, overall, preoperative magnetic resonance imaging was no more accurate than clinical evaluation with or without mammography in predicting implant status: magnetic resonance imaging 124 of 160 (78 percent) and clinical 121 of 159 (76 percent; p = 0.77). In the setting of capsular contracture, physical examination with or without mammogram is as accurate as magnetic resonance imaging in determining implant integrity. Although magnetic resonance imaging is a sensitive diagnostic tool, in symptomatic patients with capsular contracture, it cannot be viewed as infallible.

  19. New Generation of Los Alamos Opacity Tables

    Science.gov (United States)

    Colgan, James; Kilcrease, D. P.; Magee, N. H.; Sherrill, M. E.; Abdallah, J.; Hakel, P.; Fontes, C. J.; Guzik, J. A.; Mussack, K. A.

    2016-05-01

    We present a new generation of Los Alamos OPLIB opacity tables that have been computed using the ATOMIC code. Our tables have been calculated for all 30 elements from hydrogen through zinc and are publicly available through our website. In this poster we discuss the details of the calculations that underpin the new opacity tables. We also show several recent applications of the use of our opacity tables to solar modeling and other astrophysical applications. In particular, we demonstrate that use of the new opacities improves the agreement between solar models and helioseismology, but does not fully resolve the long-standing `solar abundance' problem. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396.

  20. The neutrino opacity of neutron rich matter

    Energy Technology Data Exchange (ETDEWEB)

    Alcain, P.N., E-mail: pabloalcain@gmail.com [Departamento de Física, FCEyN, UBA and IFIBA, Conicet, Pabellón 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); IFIBA-CONICET (Argentina); Dorso, C.O. [Departamento de Física, FCEyN, UBA and IFIBA, Conicet, Pabellón 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); IFIBA-CONICET (Argentina)

    2017-05-15

    The study of neutron rich matter, present in neutron star, proto-neutron stars and core-collapse supernovae, can lead to further understanding of the behavior of nuclear matter in highly asymmetric nuclei. Heterogeneous structures are expected to exist in these systems, often referred to as nuclear pasta. We have carried out a systematic study of neutrino opacity for different thermodynamic conditions in order to assess the impact that the structure has on it. We studied the dynamics of the neutrino opacity of the heterogeneous matter at different thermodynamic conditions with semiclassical molecular dynamics model already used to study nuclear multifragmentation. For different densities, proton fractions and temperature, we calculate the very long range opacity and the cluster distribution. The neutrino opacity is of crucial importance for the evolution of the core-collapse supernovae and the neutrino scattering.

  1. Magnetic resonance evaluation of the labral capsular ligamentous complex: a pictorial review

    International Nuclear Information System (INIS)

    Connell, D.A.; Potter, H.G.

    1999-01-01

    Magnetic resonance imaging of the shoulder is a common imaging test, and in the course of routine evaluation it can provide accurate information regarding the labral capsular ligamentous complex (LCLC). Common patterns of labral injury include fraying, flap tears and labral distraction, which can be readily identified on both coronal and axial planes by paying attention to signal and morphological characteristics. Capsular and ligamentous pathology may be subtle, but is recognizable using a high-resolution technique that has differential contrast between native intra-articular fluid and the adjacent labrum and capsular restraints. Common patterns of capsular injury include a thickened, hyperintense capsule, sometimes with disruption and retraction. The inferior glenohumeral ligament is the primary stabilizer of the shoulder joint, and although failure of this structure is uncommon, the injury is easily identified. Shoulder instability is a common presentation, the diagnosis of which is dependent upon recognising various injury patterns including Bankart lesions, reverse Bankart lesions, anterior labroligamentous periosteal sleeve avulsion (ALPSA) and failure of the inferior glenohumeral ligament. Copyright (1999) Blackwell Science Pty Ltd

  2. INTERPLAY OF NEUTRINO OPACITIES IN CORE-COLLAPSE SUPERNOVA SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Lentz, Eric J. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37996-1200 (United States); Mezzacappa, Anthony; Hix, W. Raphael [Physics Division, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6354 (United States); Messer, O. E. Bronson [National Center for Computational Sciences, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6164 (United States); Bruenn, Stephen W., E-mail: elentz@utk.edu [Department of Physics, Florida Atlantic University, 777 Glades Road, Boca Raton, FL 33431-0991 (United States)

    2012-11-20

    We have conducted a series of numerical experiments using spherically symmetric, general relativistic, neutrino radiation hydrodynamics with the code Agile-BOLTZTRAN to examine the effects of modern neutrino opacities on the development of supernova simulations. We test the effects of opacities by removing opacities or by undoing opacity improvements for individual opacities and groups of opacities. We find that improvements to electron capture (EC) on nuclei, namely EC on an ensemble of nuclei using modern nuclear structure models rather than the simpler independent-particle approximation (IPA) for EC on a mean nucleus, plays the most important role during core collapse of all tested neutrino opacities. Low-energy neutrinos emitted by modern nuclear EC preferentially escape during collapse without the energy downscattering on electrons required to enhance neutrino escape and deleptonization for the models with IPA nuclear EC. During shock breakout the primary influence on the emergent neutrinos arises from non-isoenergetic scattering (NIS) on electrons. For the accretion phase, NIS on free nucleons and pair emission by e {sup +} e {sup -} annihilation have the largest impact on the neutrino emission and shock evolution. Other opacities evaluated, including nucleon-nucleon bremsstrahlung and especially neutrino-positron scattering, have little measurable impact on neutrino emission or shock dynamics. Modern treatments of nuclear EC, e {sup +} e {sup -}-annihilation pair emission, and NIS on electrons and free nucleons are critical elements of core-collapse simulations of all dimensionality.

  3. NASCA Report 2: Longitudinal Study of Relationship of Exposure to Space Radiation and Risk of Lens Opacity

    Science.gov (United States)

    Chylack, Leon T., Jr.; Peterson, Leif E.; Feiveson, Alan H.; Tung, William H.; Wear, Mary L.; Marak, Lisa J.; Hardy, Dale S.; Cucinotta, Francis A.

    2011-01-01

    The NASA Study of Cataract in Astronauts (NASCA) was a five-year longitudinal study of the effect of space radiation exposure on the severity/progression of nuclear (N), cortical (C), and posterior subcapsular (PSC) lens opacities. It began in 2003 and was completed in December, 2009. Participants included 171 consenting astronauts who flew at least one mission in space, and comparison subjects consisted of three groups, a) 53 astronauts who had not flown in space, b) 95 military aircrew personnel, and c) 99 non-aircrew, ground-based subjects.

  4. Effective Opacity for Gold-Doped Foam Plasmas

    International Nuclear Information System (INIS)

    Huang Cheng-Wu; Song Tian-Ming; Zhao Yang; Zhu Tuo; Shang Wan-Li; Xiong Gang; Zhang Ji-Yan; Yang Jia-Min; Jiang Shao-En

    2012-01-01

    Radiation flow through gold-doped hydrocarbon foam is investigated and a model is presented to calculate effective opacity for an inhomogeneous, pressure-equilibrated gold/foam mixture based on the Levermore—Pomraning method for binary stochastic media. The effective opacity dependance on the size of the gold particles and the foam temperature are studied. The results suggest that when the mixture temperature is lower than 250 eV, the opacity difference between the 5 μm particle mix case and the atomic mix case is large enough to induce a significant discrepancy in radiation transport, which is confirmed by the hydrodynamic simulation

  5. Arthroscopic management of posterior instability: evolution of technique and results.

    Science.gov (United States)

    Savoie, Felix H; Holt, M Shaun; Field, Larry D; Ramsey, J Randall

    2008-04-01

    The purpose of this study was to evaluate the effectiveness of arthroscopic posterior shoulder reconstruction. We treated 136 shoulders in 131 patients with a diagnosis of primary posterior instability who failed 6 months of vigorous rehabilitation by operative stabilization between 1989 and 2001. Inclusion criterion was primary posterior instability that failed an extensive rehabilitative program with functional impairment and pain. Exclusion criterion was less than 12 months of follow-up and Suretac (Smith & Nephew, Andover, MA) or laser stabilization, leaving 92 shoulders in 90 patients available for the study (69 male, 21 female). Follow-up ranged from 12 to 132 months (average, 28 months). Each patient underwent diagnostic arthroscopy and surgical repair at the same time using one of several primary procedures. The procedure used was based on the pathologic entity noted at the time of surgery. At an average follow-up of 28 months, 97% of the shoulders were stable and considered a success based on the Neer-Foster rating scale. Posterior pathology varied, and a reverse Bankart lesion alone was found 51% of the time, a stretched posterior capsule 67% of the time, and a combination of a reverse Bankart lesion and capsular stretching 16% of the time. The rotator interval was obviously damaged in 61% of cases. Multiple accompanying lesions were found, including anterior-superior labral tears and SLAP tears (20%), superior glenohumeral ligament injury (7%), middle glenohumeral ligament injury (38%), anteroinferior glenohumaral ligament injury (37%), and an enlarged axillary pouch (20%). No essential lesion is present for posterior instability. Multiple varied pathologies will be present in a shoulder presenting with posterior instability. Arthroscopic surgery allows inspection of the joint and anatomic-specific repairs based on pathology. Careful attention to all the supporting structures of the shoulder, including the rotator interval, the anterior-superior labrum

  6. OPserver: opacities and radiative accelerations on demand

    Science.gov (United States)

    Mendoza, C.; González, J.; Seaton, M. J.; Buerger, P.; Bellorín, A.; Meléndez, M.; Rodríguez, L. S.; Delahaye, F.; Zeippen, C. J.; Palacios, E.; Pradhan, A. K.

    2009-05-01

    We report on developments carried out within the Opacity Project (OP) to upgrade atomic database services to comply with e-infrastructure requirements. We give a detailed description of an interactive, online server for astrophysical opacities, referred to as OPserver, to be used in sophisticated stellar modelling where Rosseland mean opacities and radiative accelerations are computed at every depth point and each evolution cycle. This is crucial, for instance, in chemically peculiar stars and in the exploitation of the new asteroseismological data. OPserver, downloadable with the new OPCD_3.0 release from the Centre de Données Astronomiques de Strasbourg, France, computes mean opacities and radiative data for arbitrary chemical mixtures from the OP monochromatic opacities. It is essentially a client-server network restructuring and optimization of the suite of codes included in the earlier OPCD_2.0 release. The server can be installed locally or, alternatively, accessed remotely from the Ohio Supercomputer Center, Columbus, Ohio, USA. The client is an interactive web page or a subroutine library that can be linked to the user code. The suitability of this scheme in grid computing environments is emphasized, and its extension to other atomic database services for astrophysical purposes is discussed.

  7. Serendipity and Holism: The Beauty of OPACs.

    Science.gov (United States)

    Rice, James

    1988-01-01

    Identifies factors which may account for user dissatisfaction with online public access catalogs (OPACs) and discusses some advantages of OPACs over card catalogs: (1) design for subject searching; (2) flexibility; (3) browsing capability; (4) precision; (5) availability of status information; and (6) development of microcomputer software to…

  8. IPOPv2 online service for the generation of opacity tables

    International Nuclear Information System (INIS)

    Delahaye, Franck; Zwölf, Carlo Maria; Zeippen, Claude J.; Mendoza, Claudio

    2016-01-01

    In the framework of the present phase – IPOPv2 – of the international Opacity Project (OP), a new web service has been implemented based on the latest release of the OP opacities. The user may construct online opacity tables to be conveniently included in stellar evolution codes in the format most commonly adopted by stellar physicists, namely the OPAL format. This facility encourages the use and comparison of both the OPAL and OP data sets in applications. The present service allows for the calculation of multi-element mixtures containing the 17 species (H, He, C, N, O, Ne, Na, Mg, Al, Si, S, Ar, Ca, Cr, Mn, Fe and Ni) considered by the OP, and underpins the latest release of OP opacities. This new service provides tables of Rosseland mean opacites using OP atomic data. We provide an alternative to the OPAL opacity services allowing direct comparison as well as study of the effect of uncertainties in stellar modeling due to mean opacities. - Highlights: • A new opacity table service is presented. • This is an alternative to the OPAL service, using The Opacity Project (OP) data. • These tables can directly replace the OPAL data in stellar code without any change in the code.

  9. Using Web Services for a Mobile OPAC

    Directory of Open Access Journals (Sweden)

    Denis Galvin

    2011-04-01

    Full Text Available The purpose of this paper is to discuss the creation and intended evolution of the Rice University mobile online public access catalog (OPAC. The focus of the article is on how SirsiDynix’s Symphony Web Services can be used to create a mobile OPAC.

  10. SOLAR MIXTURE OPACITY CALCULATIONS USING DETAILED CONFIGURATION AND LEVEL ACCOUNTING TREATMENTS

    International Nuclear Information System (INIS)

    Blancard, Christophe; Cossé, Philippe; Faussurier, Gérald

    2012-01-01

    An opacity model (OPAS) combining detailed configuration and level accounting treatments has been developed to calculate radiative opacity of plasmas in local thermodynamic equilibrium. The model is presented and used to compute spectral opacities of a solar mixture. Various density-temperature couples have been considered from the solar center up to the vicinity of the radiative/convective zone interface. For a given solar thermodynamic path, OPAS calculations are compared to Opacity Project (OP) and OPAL data. Rosseland mean opacity values are in very good agreement over all the considered solar thermodynamic path, while OPAS and OP spectral opacities of each element may vary considerably. Main sources of discrepancy are discussed.

  11. Distrofia polimorfa posterior: a propósito de un caso Posterior polymorphous dystrophy: A case presentation

    Directory of Open Access Journals (Sweden)

    Alexeide de la C. Castillo Pérez

    2008-12-01

    Full Text Available Presentamos el caso de una paciente del sexo femenino de 15 años de edad con antecedentes de miopía que acude a consulta para chequeo de su ametropía. En el examen biomicroscópico se observaron opacidades disciformes, pequeñas, de color blanco grisáceo, irregulares a nivel de la membrana de Descemet y del endotelio. Se realizó examen ocular completo, refracción, topografía, paquimetría, queratometría, biometría y microscopia confocal in vivo de la córnea. Finalmente llegamos al diagnóstico de distrofia polimorfa posterior.The case of a female 15 years-old patient with a history of myopia, who went to the physician´s office for an ametrophy checkout, was presented in this paper. The biomicroscopic examination revealed small white/gray-coloured irregular and diffuse opacities at the level of Descement´s membrane and of the endothelium. A complete ophthalmological examination was performed including visual acuity, refraction, corneal topography, pakimetry, keratometry, biometry and in vivo confocal microscopy of the cornea. Finally, posterior polymorphous dystrophy was diagnosed.

  12. Nueva variante de abordaje al surco ciliar en la fijación transescleral de lentes de cámara posterior New variant of approach to the ciliary sulcus in the transcleral fixation of posterior chamber lens

    Directory of Open Access Journals (Sweden)

    Ileana Vila Dópico

    2002-06-01

    Full Text Available Se expone una variante de abordaje al surco ciliar para la fijación del lente intraocular de cámara posterior, que está a nuestro alcance, en pacientes en que no existe soporte capsular o este es insuficiente. Se describe la técnica. Se realizó en 17 pacientes de los que se obtuvo mejoría visual en todos los casos (20/50-20/20 con un seguimiento promedio de 12 meses. Esta variante tiene la ventaja de evitar el paso de la aguja por el surco ciliar a ciegas, pues se utiliza el abordaje a través de la esclera y con ello evitamos dañar estructuras oculares aledañas evitando el riesgo de complicaciones por lo que se logra la recuperación anatómica y funcional en todos los casos.A variant to approach the ciliary sulcus for fixating the posterior chamber intraocular lens, which is within our reach, in patients with insufficient or no capsular support, is explained. The technique is described here and it was applied to 17 patients. Visual improvement was obtained in all cases (20/50-20/20 with an average follow-up of 12 months. This variant allows to prevent the blind passage of the needle through the ciliary sulcus, since it is approached via the sclera, avoiding to damage adjoining ocular structures and to have complications, and making possible the anatomic and functional recovery of all patients.

  13. Impact of Neutrino Opacities on Core-collapse Supernova Simulations

    Science.gov (United States)

    Kotake, Kei; Takiwaki, Tomoya; Fischer, Tobias; Nakamura, Ko; Martínez-Pinedo, Gabriel

    2018-02-01

    The accurate description of neutrino opacities is central to both the core-collapse supernova (CCSN) phenomenon and the validity of the explosion mechanism itself. In this work, we study in a systematic fashion the role of a variety of well-selected neutrino opacities in CCSN simulations where the multi-energy, three-flavor neutrino transport is solved using the isotropic diffusion source approximation (IDSA) scheme. To verify our code, we first present results from one-dimensional (1D) simulations following the core collapse, bounce, and ∼250 ms postbounce of a 15 {M}ȯ star using a standard set of neutrino opacities by Bruenn. A detailed comparison with published results supports the reliability of our three-flavor IDSA scheme using the standard opacity set. We then investigate in 1D simulations how individual opacity updates lead to differences with the baseline run with the standard opacity set. Through detailed comparisons with previous work, we check the validity of our implementation of each update in a step-by-step manner. Individual neutrino opacities with the largest impact on the overall evolution in 1D simulations are selected for systematic comparisons in our two-dimensional (2D) simulations. Special attention is given to the criterion of explodability in the 2D models. We discuss the implications of these results as well as its limitations and the requirements for future, more elaborate CCSN modeling.

  14. Preliminary observation about anterior capsular changes in different patients after cataract phacoemulsification

    Directory of Open Access Journals (Sweden)

    Min Wang

    2013-09-01

    Full Text Available AIM: To compare changes of anterior capsular opening size between complicated and simple cataract patients who underwent phacoemulsification and foldable IOL implantation.METHODS:Patients complicated with high myopia, primary angle-closure glaucoma(PACG, diabetic cataract and simple cataract(control groupwere selected, 25 case in each group. All patients accepted phacoemulsification by the doctor with operation experience of more than 5 000 cases, and the same 1-piece hydrophilic acrylic IOL was implanted without any complicated happened. The measured value about anterior capsular area by Image-pro plus 6.0 was greater than 23mm2. Every patient was checked regularly through dilated pupil, take photos by slit-lamp camera and area was measured after operation 1 week, 1 month, 3 and 6 months, then to record the biological changes about anterior capsular in 4 groups.RESULTS: The average anterior capsular area in 4 groups 1 week after operation had no difference(P>0.05; No difference was found between simple and complicated high myopia group 6 months after operation(P>0.05. Capsule contraction was observed in complicated POAG group 3 months after operation and in diabetes mellitus group 6 months postoperatively, the average anterior capsular area become smaller than 1 week postoperatively(PCONCLUSION: Cataract patients who complicated PACG or diabetes mellitus maybe the high-risk groups, capsule contraction will be happened 1 month after operation. For high-risk groups, we should prolong the follow-up time, enrich the observation data, and provide the clinical basis for reasonable and preventive intervention.

  15. Investigating the Effect of Cosmic Opacity on Standard Candles

    International Nuclear Information System (INIS)

    Hu, J.; Yu, H.; Wang, F. Y.

    2017-01-01

    Standard candles can probe the evolution of dark energy over a large redshift range. But the cosmic opacity can degrade the quality of standard candles. In this paper, we use the latest observations, including Type Ia supernovae (SNe Ia) from the “joint light-curve analysis” sample and Hubble parameters, to probe the opacity of the universe. A joint fitting of the SNe Ia light-curve parameters, cosmological parameters, and opacity is used in order to avoid the cosmological dependence of SNe Ia luminosity distances. The latest gamma-ray bursts are used in order to explore the cosmic opacity at high redshifts. The cosmic reionization process is considered at high redshifts. We find that the sample supports an almost transparent universe for flat ΛCDM and XCDM models. Meanwhile, free electrons deplete photons from standard candles through (inverse) Compton scattering, which is known as an important component of opacity. This Compton dimming may play an important role in future supernova surveys. From analysis, we find that about a few per cent of the cosmic opacity is caused by Compton dimming in the two models, which can be corrected.

  16. Application and experience of anterior vitrectomy in phacoemulsification

    Directory of Open Access Journals (Sweden)

    Xiao-Bo Zeng

    2016-02-01

    Full Text Available AIM: To observe and discuss the clinical application and effect of anterior vitrectomy in phacoemulsification for the treatment of vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection.METHODS:Retrospective analysis of 28 cases(35 eyeswith cataract in whom vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and intraocular lens implantation and anterior vitrectomy were performed was conducted. RESULTS:Anterior vitrectomy for timely and accurate treatment for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification was satisfied. CONCLUSION: Anterior vitrectomy has good curative effect for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and is effective with less severe complications.

  17. In vivo capsular switch in Streptococcus pneumoniae--analysis by whole genome sequencing.

    Directory of Open Access Journals (Sweden)

    Fen Z Hu

    Full Text Available Two multidrug resistant strains of Streptococcus pneumoniae - SV35-T23 (capsular type 23F and SV36-T3 (capsular type 3 were recovered from the nasopharynx of two adult patients during an outbreak of pneumococcal disease in a New York hospital in 1996. Both strains belonged to the pandemic lineage PMEN1 but they differed strikingly in virulence when tested in the mouse model of IP infection: as few as 1000 CFU of SV36 killed all mice within 24 hours after inoculation while SV35-T23 was avirulent.Whole genome sequencing (WGS of the two isolates was performed (i to test if these two isolates belonging to the same clonal type and recovered from an identical epidemiological scenario only differed in their capsular genes? and (ii to test if the vast difference in virulence between the strains was mostly - or exclusively - due to the type III capsule. WGS demonstrated extensive differences between the two isolates including over 2500 single nucleotide polymorphisms in core genes and also differences in 36 genetic determinants: 25 of which were unique to SV35-T23 and 11 unique to strain SV36-T3. Nineteen of these differences were capsular genes and 9 bacteriocin genes.Using genetic transformation in the laboratory, the capsular region of SV35-T23 was replaced by the type 3 capsular genes from SV36-T3 to generate the recombinant SV35-T3* which was as virulent as the parental strain SV36-T3* in the murine model and the type 3 capsule was the major virulence factor in the chinchilla model as well. On the other hand, a careful comparison of strains SV36-T3 and the laboratory constructed SV35-T3* in the chinchilla model suggested that some additional determinants present in SV36 but not in the laboratory recombinant may also contribute to the progression of middle ear disease. The nature of this determinants remains to be identified.

  18. Radiation-related posterior lenticular opacities in Hiroshima and Nagasaki atomic bomb survivors based on T65DR and DS86 dosimetry systems

    International Nuclear Information System (INIS)

    Otake, Masanori; Schull, W.J.

    1989-10-01

    This paper investigates the quantitative relationship of ionizing radiation to the occurrence of posterior lenticular opacities among the survivors of the atomic bombings of Hiroshima and Nagasaki, as suggested by the DS86 dosimetry system. DS86 doses are available for 1,983 (93.4%) of the 2,124 A-bomb survivors analyzed in 1982. In the DS86 system, both gamma-ray and neutron regression coefficients for the best-fitting model are positive and highly significant for the estimated energy deposited in the eye, here termed the eye organ dose. The DS86 gamma regression coefficient is almost the same as that associated with the T65DR gamma kerma, the ratio of the two coefficients being 1.1 (95% confidence limits: 0.5 - 2.3) for D86 kerma in the individual data. The relative biological effectiveness (RBE) values based on the individual gamma and neutron components of the DS86 eye organ dose are estimated to be 32.4 + 0.73/(D ν - 0.06)>0 with the 95% confidence limits ranging from 11.8 to 88.8 + 1.39/(D ν - 0.06)>0, where D ν is the neutron dose in gray. It is suggested that the neutron component could be more important for the eyes than for other sites of the body. Finally, it is interesting to observe that a linear-quadratic gamma and linear neutron model with two thresholds, which fits the data less well, produces very similar estimates of the two thresholds as the linear gamma-linear neutron-response model. In this model, however, the regression coefficient is not significantly associated with the quadratic gamma response. (J.P.N.)

  19. Opacity

    International Nuclear Information System (INIS)

    Reina N, Ramon

    2003-01-01

    Their objective is to specify and to clarify many of the terms that are frequently employees and routinely in the description of the discoveries that appear in the x-rays of the thorax and in its complementary studies as it is the case of the computerized tomography; for the previous reason, it is considered important to include the term of opacity this it should be the first term to use when it is an abnormal discovery in the x-ray that causes an increase in the lung density of any etiology

  20. Model-independent Constraints on Cosmic Curvature and Opacity

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guo-Jian; Li, Zheng-Xiang; Xia, Jun-Qing; Zhu, Zong-Hong [Department of Astronomy, Beijing Normal University, Beijing 100875 (China); Wei, Jun-Jie, E-mail: gjwang@mail.bnu.edu.cn, E-mail: zxli918@bnu.edu.cn, E-mail: xiajq@bnu.edu.cn, E-mail: zhuzh@bnu.edu.cn, E-mail: jjwei@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China)

    2017-09-20

    In this paper, we propose to estimate the spatial curvature of the universe and the cosmic opacity in a model-independent way with expansion rate measurements, H ( z ), and type Ia supernova (SNe Ia). On the one hand, using a nonparametric smoothing method Gaussian process, we reconstruct a function H ( z ) from opacity-free expansion rate measurements. Then, we integrate the H ( z ) to obtain distance modulus μ {sub H}, which is dependent on the cosmic curvature. On the other hand, distances of SNe Ia can be determined by their photometric observations and thus are opacity-dependent. In our analysis, by confronting distance moduli μ {sub H} with those obtained from SNe Ia, we achieve estimations for both the spatial curvature and the cosmic opacity without any assumptions for the cosmological model. Here, it should be noted that light curve fitting parameters, accounting for the distance estimation of SNe Ia, are determined in a global fit together with the cosmic opacity and spatial curvature to get rid of the dependence of these parameters on cosmology. In addition, we also investigate whether the inclusion of different priors for the present expansion rate ( H {sub 0}: global estimation, 67.74 ± 0.46 km s{sup −1} Mpc{sup −1}, and local measurement, 73.24 ± 1.74 km s{sup −1} Mpc{sup −1}) exert influence on the reconstructed H ( z ) and the following estimations of the spatial curvature and cosmic opacity. Results show that, in general, a spatially flat and transparent universe is preferred by the observations. Moreover, it is suggested that priors for H {sub 0} matter a lot. Finally, we find that there is a strong degeneracy between the curvature and the opacity.

  1. Solar opacities constrained by solar neutrinos and solar oscillations

    International Nuclear Information System (INIS)

    Cox, A.N.

    1989-01-01

    This review discusses the current situation for opacities at the solar center, the solar surface, and for the few million kelvin temperatures that occur below the convection zone. The solar center conditions are important because they are crucial for the neutrino production, which continues to be predicted about 4 times that observed. The main extinction effects there are free-free photon absorption in the electric fields of the hydrogen, helium and the CNO atoms, free electron scattering of photons, and the bound-free and bound-bound absorption of photons by iron atoms with two electrons in the 1s bound level. An assumption that the iron is condensed-out below the convection zone, and the opacity in the central regions is thereby reduced, results in about a 25 percent reduction in the central opacity but only a 5 percent reduction at the base of the convection zone. Furthermore, the p-mode solar oscillations are changed with this assumption, and do not fit the observed ones as well as for standard models. A discussion of the large effective opacity reduction by weakly interacting massive particles also results in poor agreement with observed p-mode oscillation frequencies. The much larger opacities for the solar surface layers from the Los Alamos Astrophysical Opacity Library instead of the widely used Cox and Tabor values show small improvements in oscillation frequency predictions, but the largest effect is in the discussion of p-mode stability. Solar oscillation frequencies can serve as an opacity experiment for the temperatures and densities, respectively, of a few million kelvin and between 0.1 and 10 g/cm 3 . Current oscillation frequency calculations indicate that possibly the Opacity Library values need an increase of typically 15 percent just at the bottom of the convection zone at 3 x 10 6 K. 41 refs., 15 figs., 1 tab

  2. The Rosseland mean opacity of interstellar grain

    International Nuclear Information System (INIS)

    Ali, A.; El Shalaby, M.A.; El-Nawawy, M.S.

    1990-10-01

    We have calculated the opacity of interstellar grains in the temperature range 10 deg. K - 1500 deg. K. Two composite grain models have been considered. One of them consists of silicate coated with ice mantle and the second has a graphite core coated also with ice mantle. These models are compared with isolated grain models. An exact analytical and computational development of Guettler's formulae for composite grain models has been used to calculate the extinction coefficient. It has been found that the thickness of the mantle affects the opacity of the interstellar grains. The opacity of composite models differs from that of the isolated models. The effect of the different species (ice, silicate and graphite) is also clear. (author). 22 refs, 4 figs, 1 tab

  3. Visualization of capsular polysaccharide induction in Acidithiobacillus ferrooxidans

    NARCIS (Netherlands)

    Bellenberg, S.; Leon Morales, C.F.; Sand, W.; Vera, M.

    2012-01-01

    Extracellular Polymeric Substances (EPS) are of fundamental importance for attachment to metal sulfides, biofilm formation and leaching efficiency of Acidithiobacillus ferrooxidans. In this work we have visualized the capsular polysaccharides (CPS) of A. ferrooxidans ATCC 23270 using the

  4. Cryptococcal capsular glucuronoxylomannan reduces ischaemia-related neutrophil influx

    NARCIS (Netherlands)

    Ellerbroek, PM; Schoemaker, RG; van Veghel, R; Hoepelman, AIM; Coenjaerts, FEJ

    Background The capsular polysaccharide glucuronoxylomannan (GXM) of Cryptococcus neoformans interferes with the chemotaxis and transendothelial migration of neutrophils. Intravenous administration of purified GXM has been shown to reduce the influx of inflammatory cells in an animal model of

  5. Computing NLTE Opacities -- Node Level Parallel Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Holladay, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-09-11

    Presentation. The goal: to produce a robust library capable of computing reasonably accurate opacities inline with the assumption of LTE relaxed (non-LTE). Near term: demonstrate acceleration of non-LTE opacity computation. Far term (if funded): connect to application codes with in-line capability and compute opacities. Study science problems. Use efficient algorithms that expose many levels of parallelism and utilize good memory access patterns for use on advanced architectures. Portability to multiple types of hardware including multicore processors, manycore processors such as KNL, GPUs, etc. Easily coupled to radiation hydrodynamics and thermal radiative transfer codes.

  6. Comparative pulsation calculations with OP and OPAL opacities

    Science.gov (United States)

    Kanbur, Shashi M.; Simon, Norman R.

    1994-01-01

    Comparative linear nonadiabatic pulsation calculations are presented using the OPAL and Opacity Project opacities. The two sets of opacities include effects due to intermediate coupling and fine structure as well as new abundances. We used two mass luminosity (M-L) relations, one standard (BIT), and one employing substantial convective core overshoot (COV). The two sets of opacities cannot be differentiated on the basis of the stellar pulsation calculations presented here. The BIT relation can model the beat and bump Cepheids with masses between 4 and 7 solar mass, while if the overshoot relation is used, masses between 2 and 6 solar mass are required. In the RR Lyrae regime, we find the inferred masses of globular cluster RRd stars to be little influenced by the choice of OPAL or OP. Finally, the limited modeling we have done is not able to constrain the Cepheid M-L relation based upon period ratios observed in the beat and bump stars.

  7. The influence of ionizing radiation on the development of posterior capsule opacification in vitro

    International Nuclear Information System (INIS)

    Dietl, B.; Hunner, S.; Herrmann, W.; Mueller, M.; Lohmann, C.; Gabel, V.P.; Marienhagen, J.

    2005-01-01

    Background and purpose: Histologically, the posterior capsule opacification (PCO) corresponds to regenerative tissue of transformed lens epithelial cells (LECs) with extracellular matrix production. In this study, the influence of ionizing radiation on proliferating LECs and the development of PCO was investigated in vitro. Material and methods: Each four and 14 pork lenses, respectively, were irradiated with 6 MeV electrons with single doses of 8, 10, 12, and 20 Gy. 1-2 h after irradiation the lens was removed by capsulorrhexis and hydrodissection. After fixation of the capsular bag in a special device the proliferation of residual LECs was examined daily. The experiment was considered to be finished when the capsular bag was completely opacified by confluent cell proliferates. Results: Single dose irradiation with electrons in a dose range from 8 to 12 Gy significantly protracted the development of PCO with complete inhibition of PCO after application of 20 Gy. Conclusion: To inhibit PCO in vitro, a single dose of 20 Gy is necessary. The actual in vitro model allows an optimal investigation of PCO formation under different external influences and is therefore very suitable for radiobiological questions. (orig.)

  8. Differential cytokine expression by human dendritic cells in response to different Porphyromonas gingivalis capsular serotypes

    NARCIS (Netherlands)

    Vernal, Rolando; León, Rubén; Silva, Augusto; van Winkelhoff, Arie J; Garcia-Sanz, Jose A; Sanz, Mariano

    2009-01-01

    AIM: Capsular polysaccharides play an important role in the virulence of Gram-positive and Gram-negative bacteria. In Porphyromonas gingivalis, six serotypes have been described based on capsular antigenicity and its pathogenicity has been correlated both in vitro and in animal models. This study

  9. Open capsular shift for multi directional shoulder instability.

    NARCIS (Netherlands)

    Tankeren, E. van; Waal Malefijt, M.C. de; Loon, C. van

    2002-01-01

    We evaluated the outcome of open antero-inferior capsular shift in 17 patients with multidirectional instability of the shoulder who failed to respond to conservative treatment. Six shoulders presented with secondary impingement syndrome and 11 with involuntary instability. The mean duration of

  10. [Open-wedge osteotomy of the glenoid for treatment of posterior shoulder instability with increased glenoid retroversion].

    Science.gov (United States)

    Pogorzelski, J; Braun, S; Imhoff, A B; Beitzel, K

    2016-12-01

    Treatment of posterior shoulder instability with increased retroversion of the glenoid using open-wedge osteotomy of the glenoid neck stabilized with an autologous bone block. Symptomatic, atraumatic posterior shoulder instability with increased retroversion (>20°) of the glenoid and previously failed conservative or surgical treatment. General contraindications against surgery. Relative contraindications: osteoporosis, nicotine abuse, or suspected patient noncompliance. Posterior approach with a 7 cm long incision starting medial of the posterolateral corner of the acromion heading to the posterior axillary fold and subsequent preparation of the deltoid muscle and the infraspinatus muscle. The posterior glenohumeral capsule is incised by performing a capsular T‑shift. The osteotomy is performed intracapsulary medial to the genoid rim. The wedge bone graft, harvested from spina scapulae or iliac spine, is placed "press fit" in position. Additional fixation of the graft is not necessary if the anterior cortex is intact. For reinforcing the posterior capsule, a posterior capsule shift should be performed. Insertion of extracapsular wound drainage. Successive wound closure. Postoperative immobilization in a 0° shoulder orthesis for 6 weeks; avoidance of horizontal abduction for 8 weeks. After removing the wound drainage, start of limited active-assisted range of motion. Over-head sports after 6 months. From 2009-2015, 6 posterior open wedge glenoid osteotomies were performed. Postoperative retroversion of the glenoid was 11.2 ± 9.4° compared to 26.0 ± 8.6° before surgery. Of 6 shoulders, 2 showed postoperative signs of persistent posterior instability; the other 4 shoulders were free of complaints. No revision surgery was needed.

  11. Genetic analysis of the capsular biosynthetic locus from all 90 pneumococcal serotypes.

    Directory of Open Access Journals (Sweden)

    Stephen D Bentley

    2006-03-01

    Full Text Available Several major invasive bacterial pathogens are encapsulated. Expression of a polysaccharide capsule is essential for survival in the blood, and thus for virulence, but also is a target for host antibodies and the basis for effective vaccines. Encapsulated species typically exhibit antigenic variation and express one of a number of immunochemically distinct capsular polysaccharides that define serotypes. We provide the sequences of the capsular biosynthetic genes of all 90 serotypes of Streptococcus pneumoniae and relate these to the known polysaccharide structures and patterns of immunological reactivity of typing sera, thereby providing the most complete understanding of the genetics and origins of bacterial polysaccharide diversity, laying the foundations for molecular serotyping. This is the first time, to our knowledge, that a complete repertoire of capsular biosynthetic genes has been available, enabling a holistic analysis of a bacterial polysaccharide biosynthesis system. Remarkably, the total size of alternative coding DNA at this one locus exceeds 1.8 Mbp, almost equivalent to the entire S. pneumoniae chromosomal complement.

  12. Los Alamos Opacities: Transition from LEDCOP to ATOMIC

    International Nuclear Information System (INIS)

    Magee, N.H.; Abdallah, J.; Colgan, J.; Hakel, P.; Kilcrease, D.P.; Mazevet, S.; Sherrill, M.; Fontes, C.J.; Zhang, H.L.

    2004-01-01

    This paper discusses the development of the ATOMIC code, a new low to mid Z opacity code, which will replace the current Los Alamos low Z opacity code LEDCOP. The ATOMIC code is based on the FINE code, long used by the Los Alamos group for spectral comparisons in local thermodynamic equilibrium (LTE) and for non-LTE calculations, utilizing the extensive databases from the atomic physics suite of codes based on the work of R. D. Cowan. Many of the plasma physics packages in LEDCOP, such as line broadening and free-free absorption, are being transferred to the new ATOMIC code. A new equation of state (EOS) model is being developed to allow higher density calculations than were possible with either the FINE or LEDCOP codes. Extensive modernization for both ATOMIC and the atomic physics code suites, including conversion to Fortran 90 and parallelization, are under way to speed up the calculations and to allow the use of expanded databases for both the LTE opacity tables and the non-LTE calculations. Future plans will be outlined, including considerations for new generation opacity tables

  13. Anterior capsular rupture following blunt ocular injury

    Science.gov (United States)

    Gremida, Anas; Kassem, Iris; Traish, Aisha

    2011-01-01

    Summary A 10-year-old boy suffered a large, oblique anterior capsular tear following blunt injury to his right eye. The boy was followed daily for hyphema resolution and progressive traumatic cataract formation. After the hyphema had resolved, the lens was removed using an anterior approach and an intraocular lens was placed with excellent visual outcome. PMID:23362402

  14. [Construction of a capsular tissue-engineered ureteral stent seeded with autologous urothelial cells].

    Science.gov (United States)

    Tan, Haisong; Fu, Weijun; Li, Jianqiang; Wang, Zhongxin; Li, Gang; Ma, Xin; Dong, Jun; Gao, Jiangping; Wang, Xiaoxiong; Zhang, Xu

    2013-01-01

    To investigate the feasibility of constructing a capsular poly L-lactic acid (PLLA) ureteral stent seeded with autologous urothelial cells using tissue engineering methods. The capsular ureteral stent was constructed by subcutaneously embedding PLLA ureteral stent in the back of beagles for 3 weeks to induce the formation of connective tissue on the surfaces. After decellularization of the stent, the expanded autologous urothelial cells were seeded on the stent. The surface structure and cell adhesion of the stent were observed using HE staining, scanning electron microscope (SEM) and immunocytochemical staining. MTT assay was used to evaluate urothelial cell proliferation on the capsular PLLA ureteral stent and on circumferential small intestinal submucosa graft. HE staining and VIII factor immunohistochemistry revealed numerous capillaries in the connective tissue encapsulating the stent without obvious local inflammatory response. The results of SEM and immunocytochemical staining showed that the capsule contained rich collagenic fibers forming three-dimensional structures, and the seeded autologous urothelial cells could adhere and well aligned on the surface. MTT assay showed normal growth of the cells on the stent as compared with the cells grown on circumferential small intestinal submucosa graft. The capsular PLLA ureteral stent allows adhesion and proliferation of autologous urothelial cells and shows a potential in applications of constructing tissue-engineered ureter.

  15. Universe opacity and CMB

    Science.gov (United States)

    Vavryčuk, Václav

    2018-04-01

    A cosmological model, in which the cosmic microwave background (CMB) is a thermal radiation of intergalactic dust instead of a relic radiation of the Big Bang, is revived and revisited. The model suggests that a virtually transparent local Universe becomes considerably opaque at redshifts z > 2 - 3. Such opacity is hardly to be detected in the Type Ia supernova data, but confirmed using quasar data. The opacity steeply increases with redshift because of a high proper density of intergalactic dust in the previous epochs. The temperature of intergalactic dust increases as (1 + z) and exactly compensates the change of wavelengths due to redshift, so that the dust radiation looks apparently like the radiation of the blackbody with a single temperature. The predicted dust temperature is TD = 2.776 K, which differs from the CMB temperature by 1.9% only, and the predicted ratio between the total CMB and EBL intensities is 13.4 which is close to 12.5 obtained from observations. The CMB temperature fluctuations are caused by EBL fluctuations produced by galaxy clusters and voids in the Universe. The polarization anomalies of the CMB correlated with temperature anisotropies are caused by the polarized thermal emission of needle-shaped conducting dust grains aligned by large-scale magnetic fields around clusters and voids. A strong decline of the luminosity density for z > 4 is interpreted as the result of high opacity of the Universe rather than of a decline of the global stellar mass density at high redshifts.

  16. The posterior transtriceps approach for elbow arthrography: a forgotten technique?

    International Nuclear Information System (INIS)

    Lohman, M.; Borrero, C.; Casagranda, B.; Rafiee, B.; Towers, J.

    2009-01-01

    To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures. (orig.)

  17. Antibiofilm activity of Actinobacillus pleuropneumoniae serotype 5 capsular polysaccharide.

    Directory of Open Access Journals (Sweden)

    Michael T Karwacki

    Full Text Available Cell-free extracts isolated from colony biofilms of Actinobacillus pleuropneumoniae serotype 5 were found to inhibit biofilm formation by Staphylococcus aureus, S. epidermidis and Aggregatibacter actinomycetemcomitans, but not by A. pleuropneumoniae serotype 5 itself, in a 96-well microtiter plate assay. Physical and chemical analyses indicated that the antibiofilm activity in the extract was due to high-molecular-weight polysaccharide. Extracts isolated from a mutant strain deficient in the production of serotype 5 capsular polysaccharide did not exhibit antibiofilm activity. A plasmid harboring the serotype 5 capsule genes restored the antibiofilm activity in the mutant extract. Purified serotype 5 capsular polysaccharide also exhibited antibiofilm activity against S. aureus. A. pleuropneumoniae wild-type extracts did not inhibit S. aureus growth, but did inhibit S. aureus intercellular adhesion and binding of S. aureus cells to stainless steel surfaces. Furthermore, polystyrene surfaces coated with A. pleuropneumoniae wild-type extracts, but not with capsule-mutant extracts, resisted S. aureus biofilm formation. Our findings suggest that the A. pleuropneumoniae serotype 5 capsule inhibits cell-to-cell and cell-to-surface interactions of other bacteria. A. pleuropneumoniae serotype 5 capsular polysaccharide is one of a growing number of bacterial polysaccharides that exhibit broad-spectrum, nonbiocidal antibiofilm activity. Future studies on these antibiofilm polysaccharides may uncover novel functions for bacterial polysaccharides in nature, and may lead to the development of new classes of antibiofilm agents for industrial and clinical applications.

  18. Transport of Streptococcus pneumoniae capsular polysaccharide in MHC Class II tubules.

    Directory of Open Access Journals (Sweden)

    Tom Li Stephen

    2007-03-01

    Full Text Available Bacterial capsular polysaccharides are virulence factors and are considered T cell-independent antigens. However, the capsular polysaccharide Sp1 from Streptococcus pneumoniae serotype 1 has been shown to activate CD4(+ T cells in a major histocompatibility complex (MHC class II-dependent manner. The mechanism of carbohydrate presentation to CD4(+ T cells is unknown. We show in live murine dendritic cells (DCs that Sp1 translocates from lysosomal compartments to the plasma membrane in MHCII-positive tubules. Sp1 cell surface presentation results in reduction of self-peptide presentation without alteration of the MHCII self peptide repertoire. In DM-deficient mice, retrograde transport of Sp1/MHCII complexes resulting in T cell-dependent immune responses to the polysaccharide in vitro and in vivo is significantly reduced. The results demonstrate the capacity of a bacterial capsular polysaccharide antigen to use DC tubules as a vehicle for its transport as an MHCII/saccharide complex to the cell surface for the induction of T cell activation. Furthermore, retrograde transport requires the functional role of DM in self peptide-carbohydrate exchange. These observations open new opportunities for the design of vaccines against microbial encapsulated pathogens.

  19. How the machine ‘thinks’: Understanding opacity in machine learning algorithms

    Directory of Open Access Journals (Sweden)

    Jenna Burrell

    2016-01-01

    Full Text Available This article considers the issue of opacity as a problem for socially consequential mechanisms of classification and ranking, such as spam filters, credit card fraud detection, search engines, news trends, market segmentation and advertising, insurance or loan qualification, and credit scoring. These mechanisms of classification all frequently rely on computational algorithms, and in many cases on machine learning algorithms to do this work. In this article, I draw a distinction between three forms of opacity: (1 opacity as intentional corporate or state secrecy, (2 opacity as technical illiteracy, and (3 an opacity that arises from the characteristics of machine learning algorithms and the scale required to apply them usefully. The analysis in this article gets inside the algorithms themselves. I cite existing literatures in computer science, known industry practices (as they are publicly presented, and do some testing and manipulation of code as a form of lightweight code audit. I argue that recognizing the distinct forms of opacity that may be coming into play in a given application is a key to determining which of a variety of technical and non-technical solutions could help to prevent harm.

  20. Opacity of expanding media: The effect of spectral lines

    International Nuclear Information System (INIS)

    Karp, A.H.; Lasher, G.; Chan, K.L.; Salpeter, E.E.

    1977-01-01

    Spectral lines are more effective in slowing the transport of radiation in expanding (or contracting) objects than in static ones. The velocity gradient associated with the expansion causes the frequency of the photons to be continuously redshifted relative to the rest frame of the gas through which they travel. Those photons which are redshifted to the frequency of a sufficiently strong line will be absorbed by the corresponding bound-bound transition, and the net effect will be to increase the effective opacity of the gas. In certain cases the effect can be taken into account by using an effective opacity, the expansion opacity, which is a function not only of the temperature and density but also of the velocity gradient.Practical formulae for computing the expansion opacity and its Rosseland mean in terms of sums over spectral lines are derived. It is shown that the cumulative effect of many weak lines can be important, implying that a large list of spectral lines is required to obtain results of even modest accuracy. Numerical computations using the 260,000-entry line list of Kurucz and Peytremann have been completed and some samples of the result are given. The general effect may be important in many astronomical objects, but only in some of these will be detailed approach of this paper be appropriate. In optically thick supernova shells, the effect is important both in maintaining the radiation in thermal equilibrium as it diffuses out of the shell and in increasing the value of the total opacity. The enhancement of the opacity ranges from less than 1% to more than an order of magnitude, depending on the temperature, density, and velocity gradient

  1. An Evaluation of Online Help for the NOTIS OPAC.

    Science.gov (United States)

    White, Frank

    1994-01-01

    Discussion of online help systems in online public access catalogs (OPACs) focuses on a study that evaluated the online help system for the NOTIS (Northwestern Online Total Integrated System) OPAC. Features of the system reviewed include online functions; training features; general interface features; access points; and message content and display…

  2. Experiment to measure oxygen opacity at high density and temperature

    Science.gov (United States)

    Keiter, Paul; Butler, Hannah; Trantham, Matt; Mussack, Katie; Colgan, James; Fontes, Chris; Guzik, Joyce; Kilcrease, David; Perry, Ted; Orban, Chris; Ducret, Jean-Eric; La Pennec, Maelle; Turck-Chieze, Sylvaine; Mancini, Roberto; Heeter, Robert

    2017-10-01

    In recent years, there has been a debate over the abundances of heavy elements (Z >2) in the solar interior. Recent solar atmosphere models [Asplund 2009] find a significantly lower abundance for C, N, and O compared to models used roughly a decade ago. Recent opacity measurements of iron disagree with opacity model predictions [Bailey et al., 2015]. Repeated scrutiny of the experiment and data has not produced a conclusive reason for the discrepancy. New models have been implemented in the ATOMIC opacity code for low-Z elements [Colgan, 2013, Armstrong 2014], however no data currently exists to test the low-Z material models in the regime relevant to the solar convection zone. We present an experimental design using the opacity platform developed at the National Ignition Facility to study the oxygen opacity at densities and temperatures near the solar convection zone conditions. This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HEDLP, Grant Number DE-NA0002956, and the NLUF Program, Grant Number DE-NA0002719, and through the LLE, University of Rochester by the NNSA/OICF under No. DE-NA0001944.

  3. Tipificación capsular mediante PCR de aislamientos de Haemophilus influenzae no tipificables por aglutinación PCR-based capsular typing of Haemophilus influenzae isolates non-typeable by agglutination

    Directory of Open Access Journals (Sweden)

    G. Weltman

    2005-12-01

    Full Text Available Haemophilus influenzae es reconocido como un agente patógeno responsable de infecciones localizadas y sistémicas. Se han descrito 6 tipos de polisacáridos capsulares antigénicamente distintos (a, b, c, d, e, y f que se pueden identificar por aglutinación en lámina con antisueros específicos. También existen cepas no capsuladas (NC fenotípicamente no tipificables (NT. La introducción de la vacuna conjugada produjo una marcada disminución de las enfermedades invasivas causadas por H. influenzae tipo b. En este contexto, la tipificación capsular mediante PCR es el método más apropiado para distinguir las cepas no capsuladas de las mutantes b deficientes en cápsula (b- y detectar la presencia de cepas pertenecientes a otros serotipos que no puedan ser tipificables por aglutinación. Se determinó el genotipo capsular a 38 aislamientos de Haemophilus influenzae no tipificables por aglutinación, derivados al servicio de Bacteriología Clínica del INEI-ANLIS "Dr. Carlos G. Malbrán" en el período 2002-2004. El 78,9% de los aislamientos provenían de hemocultivos y la mayor parte de ellos estaban asociados a foco respiratorio. El 100% de los aislamientos fueron identificados como H. influenzae no capsulados mediante la técnica de PCR.Haemophilus influenzae is recognized as a pathogenic agent responsible of localized and systemic infections. Six antigenically different capsular polysaccharide types have been described (a, b, c, d, e, and f which can be identified by slide agglutination with specific antisera. Besides there are non capsulated strains that cannot be typed by slide agglutination. The introduction of the conjugated vaccine produced an important reduction of invasive diseases caused by H. influenzae type b. Capsular typing by PCR is the most appropriated method for distinguishing non capsulated strains from capsule deficient type b mutants (b- and for detecting strains of other serotypes that cannot be detected by slide

  4. Opacity calculations for extreme physical systems: code RACHEL

    Science.gov (United States)

    Drska, Ladislav; Sinor, Milan

    1996-08-01

    Computer simulations of physical systems under extreme conditions (high density, temperature, etc.) require the availability of extensive sets of atomic data. This paper presents basic information on a self-consistent approach to calculations of radiative opacity, one of the key characteristics of such systems. After a short explanation of general concepts of the atomic physics of extreme systems, the structure of the opacity code RACHEL is discussed and some of its applications are presented.

  5. [Imaging manifestations and pathologic basis for hepatic capsular retraction syndrome caused by benign and malignant liver tumors].

    Science.gov (United States)

    Ou, Youkuan; Xiao, Enhua; Shang, Quanliang; Chen, Juan

    2015-10-01

    To investigate the imaging manifestations of CT, MRI and pathological basis for hepatic capsular retraction syndrome caused by benign and malignant liver tumors.
 CT or MRI images and pathological features for hepatic capsular retraction syndrome were retrospectively analyzed in 50 patients with benign and malignant liver tumors. Picture archive and communication system (PACS) was used to observe and compare the morphology, size, width, depth, edge of the capsular retraction and the status of liquid under the liver capsule. The structure, differentiation and proliferation of the tumor were analyzed under the microscope.
 There were malignant liver tumors in 44 patients and benign tumor in 6 patients. The smooth or rough for the edge of capsular retraction was significant difference between the benign tumors and the malignant tumors with three differentiated grades (all PBenign and malignant hepatic tumors may appear capsule retraction syndrome, but there are morphological differences between them. The differences are closely related with the lesion size, differentiated degree of tumor and fibrous tissue proliferation.

  6. Verification of Opacity and Diagnosability for Pushdown Systems

    Directory of Open Access Journals (Sweden)

    Koichi Kobayashi

    2013-01-01

    Full Text Available In control theory of discrete event systems (DESs, one of the challenging topics is the extension of theory of finite-state DESs to that of infinite-state DESs. In this paper, we discuss verification of opacity and diagnosability for infinite-state DESs modeled by pushdown automata (called here pushdown systems. First, we discuss opacity of pushdown systems and prove that opacity of pushdown systems is in general undecidable. In addition, a decidable class is clarified. Next, in diagnosability, we prove that under a certain assumption, which is different from the assumption in the existing result, diagnosability of pushdown systems is decidable. Furthermore, a necessary condition and a sufficient condition using finite-state approximations are derived. Finally, as one of the applications, we consider data integration using XML (Extensible Markup Language. The obtained result is useful for developing control theory of infinite-state DESs.

  7. Isolation of a bacteriophage specific for a new capsular type of Klebsiella pneumoniae and characterization of its polysaccharide depolymerase.

    Directory of Open Access Journals (Sweden)

    Chun-Ru Hsu

    Full Text Available BACKGROUND: Klebsiella pneumoniae is one of the major pathogens causing hospital-acquired multidrug-resistant infections. The capsular polysaccharide (CPS is an important virulence factor of K. pneumoniae. With 78 capsular types discovered thus far, an association between capsular type and the pathogenicity of K. pneumoniae has been observed. METHODOLOGY/PRINCIPAL FINDINGS: To investigate an initially non-typeable K. pneumoniae UTI isolate NTUH-K1790N, the cps gene region was sequenced. By NTUH-K1790N cps-PCR genotyping, serotyping and determination using a newly isolated capsular type-specific bacteriophage, we found that NTUH-K1790N and three other isolates Ca0507, Ca0421 and C1975 possessed a new capsular type, which we named KN2. Analysis of a KN2 CPS(- mutant confirmed the role of capsule as the target recognized by the antiserum and the phage. A newly described lytic phage specific for KN2 K. pneumoniae, named 0507-KN2-1, was isolated and characterized using transmission electron microscopy. Whole-genome sequencing of 0507-KN2-1 revealed a 159 991 bp double-stranded DNA genome with a G+C content of 46.7% and at least 154 open reading frames. Based on its morphological and genomic characteristics, 0507-KN2-1 was classified as a member of the Myoviridae phage family. Further analysis of this phage revealed a 3738-bp gene encoding a putative polysaccharide depolymerase. A recombinant form of this protein was produced and assayed to confirm its enzymatic activity and specificity to KN2 capsular polysaccharides. KN2 K. pneumoniae strains exhibited greater sensitivity to this depolymerase than these did to the cognate phage, as determined by spot analysis. CONCLUSIONS/SIGNIFICANCE: Here we report that a group of clinical strains possess a novel Klebsiella capsular type. We identified a KN2-specific phage and its polysaccharide depolymerase, which could be used for efficient capsular typing. The lytic phage and depolymerase also have potential as

  8. Effect of ropy and capsular exopolysaccharides producing strain of ...

    African Journals Online (AJOL)

    The contribution of selected ropy and capsular Lactobacillus plantarum 162RM on texture of fermented milk as well as on the functionality of kareish cheese was established in this study. The cell suspension of this strain was used in combination with commercial starter cultures MY900 (Lactobacillus delbrueckii ssp.

  9. Perilaku Pemustaka Dalam Temu Kembali Koleksi Dengan Menggunakan OPAC Berbasis SLIMS

    Directory of Open Access Journals (Sweden)

    Mujiati Mujiati

    2014-07-01

    Full Text Available Abstract: An  increase of  library collection and  information explosion causes  problems  on    information  retrieval  for  library  users.  Those explosion will be helpful for users using Online Public Access Catalog (OPAC. This article tries to explore the use of OPAC based SLIMs on STAIN Ponorogo  library. OPAC proves  to help users  on  retrieval  be easier and faster, beside its obstacles

  10. Assessment of subpleural opacities on high-resolution CT

    International Nuclear Information System (INIS)

    Choi, Hee Seok; Kim, Jeung Sook; Kang, Eun Young; Kim, Hak Hee

    2007-01-01

    The purpose of this study was to assess the value of HRCT for determining the cause of subpleural opacities. We evaluated 49 cases of subpleural opacities on HRCT scan, among with the patients with subpleural opacities seen on the conventional chest radiographs. Two 'blinded' reviewers retrospectively analyzed the CT scans by working in consensus. The patients consisted of COP (n = 14), NSIP (n = 13), UIP (n = 10), fibrosis associated with connective tissue disease or drug toxicity (n = 4), CEP (n = 4), Churg-Strauss syndrome (n = 2), DIP (n = 1) and AIP (n = 1). The predominant findings were consolidation (57%) with a peribronchovascular distribution (57%) in the COP patients, GGO (69%) and the associated focal reticular densities (61%) in the NSIP patients, and reticular or reticulonodular densities with a paucity of GGO in the UIP patients (100%). For the diagnosis of COP, NSIP and UIP, the use of HRCT demonstrated a high sensitivity (86%, 85% and 90%, respectively), specificity (97%, 86% and 95%) and accuracy (94%, 86% and 94%). Although an overlap of CT findings is seen for diseases showing subpleural opacities, consolidation with a subpleural and peribronchovascular distribution is highly suggestive for COP, subpleural GGO is highly suggestive of NSIP, subpleural reticular or reticulonodular densities with a paucity of GGO is highly suggestive of UIP and subpleural consolidation accompanied by reticular densities is suggestive of fibrosis

  11. Assessment of subpleural opacities on high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hee Seok; Kim, Jeung Sook [Dngguk University International Hospital, Goyang (Korea, Republic of); Kang, Eun Young [Korea University Guro Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2007-11-15

    The purpose of this study was to assess the value of HRCT for determining the cause of subpleural opacities. We evaluated 49 cases of subpleural opacities on HRCT scan, among with the patients with subpleural opacities seen on the conventional chest radiographs. Two 'blinded' reviewers retrospectively analyzed the CT scans by working in consensus. The patients consisted of COP (n = 14), NSIP (n = 13), UIP (n = 10), fibrosis associated with connective tissue disease or drug toxicity (n = 4), CEP (n = 4), Churg-Strauss syndrome (n = 2), DIP (n = 1) and AIP (n = 1). The predominant findings were consolidation (57%) with a peribronchovascular distribution (57%) in the COP patients, GGO (69%) and the associated focal reticular densities (61%) in the NSIP patients, and reticular or reticulonodular densities with a paucity of GGO in the UIP patients (100%). For the diagnosis of COP, NSIP and UIP, the use of HRCT demonstrated a high sensitivity (86%, 85% and 90%, respectively), specificity (97%, 86% and 95%) and accuracy (94%, 86% and 94%). Although an overlap of CT findings is seen for diseases showing subpleural opacities, consolidation with a subpleural and peribronchovascular distribution is highly suggestive for COP, subpleural GGO is highly suggestive of NSIP, subpleural reticular or reticulonodular densities with a paucity of GGO is highly suggestive of UIP and subpleural consolidation accompanied by reticular densities is suggestive of fibrosis.

  12. Avaliação do uso do anel endocapsular modificado em casos de subluxação traumática do cristalino Evaluation of the modified capsular tension ring in cases of traumatic lens subluxation

    Directory of Open Access Journals (Sweden)

    Daniela Meira Villano Marques

    2007-10-01

    Full Text Available OBJETIVO: Avaliar o comportamento do anel modificado de tensão capsular em cataratas traumáticas com subluxação, analisando a acuidade visual, centração do saco capsular, pseudofacodonese, seguimento pós-operatório, e complicações intra e pós-operatórias. LOCAL: Cincinnati Eye Institute, Cincinnati, Ohio, USA. MÉTODOS: Vinte e dois olhos de 22 pacientes com perda traumática de suporte zonular foram submetidos à facoemulsificação utilizando lente intra-ocular de câmara posterior e o implante do anel capsular modificado. O exame pré-operatório incluiu melhor acuidade visual corrigida (MAVC, a presença ou ausência de facodonese, descentração do cristalino e prolapso vítreo. A avaliação pós-operatória incluiu MAVC, presença de pseudofacodonese, centração do implante, necessidade de vitrectomia e outras complicações. RESULTADOS: Vinte e um olhos (95,45% tiveram melhora da MAVC. O exame pré-operatório revelou facodonese em 11 olhos (50% e nenhum olho apresentou pseudofacodonese. No exame pré-operatório, a descentração sintomática estava presente em 10 olhos (45,45%. Todos os olhos apresentaram centração do complexo saco capsular/LIO no pós-operatório. Prolapso vítreo foi diagnosticado antes da cirurgia em 9 olhos (40,90% e a vitrectomia foi necessária em 11 olhos (50%. CONCLUSÃO: O uso do anel modificado de tensão capsular resultou em boa centração do complexo saco capsular/lente intra-ocular nos olhos estudados com catarata traumática e perda de suporte zonular.PURPOSE: To evaluate the behavior of the modified capsular tension ring (MCTR in traumatic subluxated cataracts analyzing the visual acuity, centration of the capsular bag, pseudophacodonesis, postoperative follow-up and intra- and postoperative complications. SETTING: Cincinnati Eye Institute, Cincinnati, Ohio, USA. METHODS: Twenty-two eyes of 22 patients with traumatic loss of zonular support had phacoemulsification using PCIOL and MCTR

  13. OPACs in the Clouds

    Science.gov (United States)

    Webb, Paula L.; Nero, Muriel D.

    2009-01-01

    In today's world of instant everything, everyone has been exposed to some form of Web 2.0 technology, and higher education is not exempt from its long reach. Libraries of all types are incorporating Web 2.0 features to attract users as well as to showcase library services. The Online Public Access Catalog (OPAC) has become more user-friendly with…

  14. OPACs en Web: entre la tradición y la innovación = OPACs on the Web: Between tradition and innovation

    Directory of Open Access Journals (Sweden)

    Purificación Moscoso

    2002-06-01

    Full Text Available El desarrollo de Internet ha impulsado la implementación de OPACs en este entorno. Se analizan los cambios que estos nuevos OPACs suponen en cuanto a: estructura, gestión y mantenimiento del catálogo; sistemas de recuperación e interfaz del usuario. La pervivencia de prácticas tradicionales en la estructura y organización de la información impide que se les considere una herramienta innovadora. Se estudia la estructura de la base de datos, así como los principios tradicionales que rigen su elaboración. Se analizan las repercusiones que lleva consigo seguir utilizando reglas y formatos diseñados para un entorno manual que nada tiene que ver con el nuevo entorno tecnológico en el que hoy en día nos movemos = Internet development has driven the implementation of OPACs in that environment. Changes of these new OPACs as referred to catalog structure, management, and maintenance, retrieval systems and user interface are analyzed. The survival of traditional practices in the information structure and organization avoids them to be considered an innovative tool. The database structure is studied as well as the traditional principles that govern their elaboration. Effects of keeping using rules and formats designed for a manual environment, which is absolutely different from the present day technological environment are analyzed.

  15. OPACs en Web: entre la tradición y la innovación OPACs on the Web: Between tradition and innovation

    Directory of Open Access Journals (Sweden)

    Purificación Moscoso

    2002-06-01

    Full Text Available El desarrollo de Internet ha impulsado la implementación de OPACs en este entorno. Se analizan los cambios que estos nuevos OPACs suponen en cuanto a: estructura, gestión y mantenimiento del catálogo; sistemas de recuperación e interfaz del usuario. La pervivencia de prácticas tradicionales en la estructura y organización de la información impide que se les considere una herramienta innovadora. Se estudia la estructura de la base de datos, así como los principios tradicionales que rigen su elaboración. Se analizan las repercusiones que lleva consigo seguir utilizando reglas y formatos diseñados para un entorno manual que nada tiene que ver con el nuevo entorno tecnológico en el que hoy en día nos movemos.Internet development has driven the implementation of OPACs in that environment. Changes of these new OPACs as referred to catalog structure, management, and maintenance, retrieval systems and user interface are analyzed. The survival of traditional practices in the information structure and organization avoids them to be considered an innovative tool. The database structure is studied as well as the traditional principles that govern their elaboration. Effects of keeping using rules and formats designed for a manual environment, which is absolutely different from the present day technological environment are analyzed.

  16. Lens Opacity and Hydrogen Sulfide in a New Zealand Geothermal Area.

    Science.gov (United States)

    Bates, Michael N; Bailey, Ian L; DiMartino, Robert B; Pope, Karl; Crane, Julian; Garrett, Nick

    2017-04-01

    Hydrogen sulfide (H2S) is a highly toxic gas with well-established, acute irritation effects on the eye. The population of Rotorua, New Zealand, sited on an active geothermal field, has some of the highest ambient H2S exposures in the world. Evidence from ecological studies in Rotorua has suggested that H2S is associated with cataract. The purpose of the present study was, using more detailed exposure characterization, clinical examinations, and anterior eye photography, to more directly investigate this previously reported association. Enrolled were 1637 adults, ages 18 to 65, from a comprehensive Rotorua primary care medical register. Patients underwent a comprehensive ophthalmic examination, including pupillary dilation and lens photography to capture evidence of any nuclear opacity, nuclear color, and cortical and posterior subcapsular opacity. Photographs were scored for all four outcomes on the LOCS III scale with decimalized interpolation between the exemplars. H2S exposure for up to the last 30 years was estimated based on networks of passive samplers set out across Rotorua and knowledge of residential, workplace, and school locations over the 30 years. Data analysis using linear and logistic regression examined associations between the degree of opacification and nuclear color or cataract (defined as a LOCS III score ≥2.0) in relation to H2S exposure. No associations were found between estimated H2S exposures and any of the four ophthalmic outcome measures. Overall, results were generally reassuring. They provided no evidence that H2S exposure at the levels found in Rotorua is associated with cataract. The previously found association between cataract and H2S exposure in the Rotorua population seems likely to be attributable to the limitations of the ecological study design. These results cannot rule out the possibility of an association with cataract at higher levels of H2S exposure.

  17. The influence of injection volume and capsular bag contraction on the refractive power of polymer refilled lenses - a finite element modelling simulation study.

    Science.gov (United States)

    Martin, Heiner; Guthoff, Rudolf; Schmitz, Klaus-Peter

    2011-09-01

    Polymer injection into the capsular bag after phakoemulsification is an interesting and promising approach to lens surgery. Safe clinical application of this technique will require an appropriate estimate of the effect of implantation variables on the lens power. This article details the results of finite element investigations into the effects of the injected polymer volume and capsular bag contraction on the resultant lens power and accommodation amplitude. An axisymmetric finite element model was created from literature sources. Polymer injection and the capsular contraction were simulated, and their effect on the lens power was calculated. The simulations show that overfilling during polymer injection leads to a refractive power increase of the lens. Capsular bag contraction also results in a power increase. The calculated accommodative amplitude of the lens is minimally affected by capsular bag contraction but decreases significantly with increased capsular bag stiffness as a result of fibrosis. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  18. Anterior dislocation of an empty capsular bag in a pseudophakic eye: A rare case report

    Directory of Open Access Journals (Sweden)

    Hyung Bin Hwang

    2015-01-01

    Full Text Available Spontaneous intraocular lens (IOL dislocation is uncommon in the absence of any ocular areas with zonular weakness or trauma. There have been no reports of spontaneous capsular bag dislocation into the anterior chamber without an IOL. We report a rare, interesting case of spontaneous capsular bag anterior dislocation, without an IOL, into the anterior chamber with no history of genetic disease, ocular trauma, or pseudoexfoliation that might predispose to a zonular abnormality.

  19. Surgical management of spontaneous in-the-bag intraocular lens and capsular tension ring complex dislocation

    Directory of Open Access Journals (Sweden)

    Uzeyir Gunenc

    2014-01-01

    Full Text Available We describe a technique to manage late spontaneous intraocular lens (IOL and capsular tension ring (CTR dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o′clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.

  20. Dialogue with an OPAC: How Visionary Was Swanson in 1964?

    Science.gov (United States)

    Su, Shiao-Feng

    1994-01-01

    Traces the development of online public access catalogs (OPACs) and compares what has occurred with a 1964 article that outlined recommendations for a future card catalog. Subject access is emphasized, including Library of Congress Subject Headings, expansion of OPACs, user-friendly interfaces, new technologies, and current visions of the future…

  1. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  2. Evaluation of pars plana sclera fixation of posterior chamber intraocular lens

    Directory of Open Access Journals (Sweden)

    Fangju Han

    2014-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL implantation with transscleral fixation. Design and Setting: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second People′s Hospital. Materials and Methods: A total of 82 patients who were scheduled for sutured PCIOL were divided randomly into modified and conventional groups. The former underwent PCIOL through pars plana fixation with knot buried and without scleral flap and the latter underwent transscleral fixation of PCIOL in the ciliary sulcus. The main outcome measures included operative time, postoperative visual acuity, and postoperative complications. Results: The mean operative time of the modified group was 39.95 ± 5.87 min, which was significantly less than that of the conventional group (45.77 ± 5.21 min; P < 0.05. No difference was found in postoperative visual acuity between the two groups. There were no significant postoperative complications, including knot exposure, endophthalmitis, and retinal detachment in either group. The optical clamping of PCIOL was prone to occur in the conventional group. Conclusion: Modified sutured PCIOL implantation is a safe, effective, and feasible technique for the correction of aphakia in eyes without adequate posterior capsular support.

  3. Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas

    Directory of Open Access Journals (Sweden)

    Matthew R. Bald

    2013-01-01

    Full Text Available Purpose. To evaluate Fourier-domain optical coherence tomography (FD-OCT as an adjunct to traditional slit lamp examination of donor corneas with suspected Anterior Stromal Opacities. Methods. Seven corneas suspected of having anterior stromal opacities by slit lamp examination were evaluated with FD-OCT. Each cornea was evaluated to confirm the presence of opacity and, if present, the depth of opacity was measured. Results. The opacity depth ranged from 82 μm to 624 μm. The initial slit lamp impressions of five of the seven corneas were confirmed by OCT. In two corneas, the OCT findings were different from the initial slit lamp impressions. Slit lamp examination of the first cornea gave the impression of anterior stromal scarring, but OCT showed that the opacity was limited to the epithelium. Slit lamp examination of the second cornea suggested opacity limited to the epithelium, but OCT identified significant sub-Bowman's scarring. In all cases, the Eye Bank Technicians reported that the location and depth of corneal opacity were more sharply defined by OCT than by slit lamp. Conclusion. The high resolution of OCT makes it easier to determine the location of corneal opacities compared to slit lamp examinations. This enhanced visualization can improve decisions regarding transplant suitability of donor corneas.

  4. Measuring the opacity of stellar interior matter in terrestrial laboratories

    Science.gov (United States)

    Bailey, James

    2015-11-01

    How does energy propagate from the core to the surface of the Sun, where it emerges to warm the Earth? Nearly a century ago Eddington recognized that the attenuation of radiation by stellar matter controls the internal structure of stars like the sun. Opacities for high energy density (HED) matter are challenging to calculate because accurate and complete descriptions of the energy levels, populations, and plasma effects such as continuum lowering and line broadening are needed for partially ionized atoms. This requires approximations, in part because billions of bound-bound and bound-free electronic transitions can contribute to the opacity. Opacity calculations, however, have never been benchmarked against laboratory measurements at stellar interior conditions. Laboratory opacity measurements were limited in the past by the challenges of creating and diagnosing sufficiently large and uniform samples at the extreme conditions found inside stars. In research conducted over more than 10 years, we developed an experimental platform on the Z facility and measured wavelength-resolved iron opacity at electron temperatures Te = 156-195 eV and densities ne = 0.7-4.0 x 1022 cm-3 - conditions very similar to the radiation/convection boundary zone within the Sun. The wavelength-dependent opacity in the 975-1775 eV photon energy range is 30-400% higher than models predict. This raises questions about how well we understand the behavior of atoms in HED plasma. These measurements may also help resolve decade-old discrepancies between solar model predictions and helioseismic observations. This talk will provide an overview of the measurements, investigations of possible errors, and ongoing experiments aimed at testing hypotheses to resolve the model-data discrepancy. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  5. FIRST NEW SOLAR MODELS WITH OPAS OPACITY TABLES

    Energy Technology Data Exchange (ETDEWEB)

    Le Pennec, M.; Turck-Chièze, S.; Salmon, S. [CEA/IRFU/Service d’Astrophysique, CE Saclay, F-91191 Gif sur Yvette (France); Blancard, C.; Cossé, P.; Faussurier, G.; Mondet, G. [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-11-10

    Stellar seismology appears more and more as a powerful tool for a better determination of the fundamental properties of solar-type stars. However, the particular case of the Sun is still challenging. For about a decade now, the helioseismic sound-speed determination has continued to disagree with the standard solar model (SSM) prediction, questioning the reliability of this model. One of the sources of uncertainty could be in the treatment of the transport of radiation from the solar core to the surface. In this Letter, we use the new OPAS opacity tables, recently available for solar modeling, to address this issue. We discuss first the peculiarities of these tables, then we quantify their impact on the solar sound-speed and density profiles using the reduced OPAS tables taken on the grids of the OPAL ones. We use the two evolution codes, Modules for Experiments in Stellar Astrophysics and Code Liégeois d’Evolution Stellaire, that led to similar conclusions in the solar radiative zone. In comparison to commonly used OPAL opacity tables, the new solar models are computed for the most recent photospheric composition with OPAS tables and present improvements to the location of the base of the convective zone and to the description of the solar radiative zone in comparison to the helioseismic observations, even if the differences in the Rosseland mean opacity do not exceed 6%. We finally carry out a comparison to a solar model computed with the OP opacity tables.

  6. Summary of Fe opacity measurement platform

    Energy Technology Data Exchange (ETDEWEB)

    Nagayama, Taisuke

    2016-05-01

    This powerpoint presentation goes over the Fe opacity measurement platform, including how the experiment works, what can be gathered from the measurements, what can be gathered from the simulations, and the limitations of the experiment.

  7. MR imaging findings of renal capsular leiomyoma : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Jin Woo; Cho, Hyun I; Lee, Jong Bouk [Gachon Medical college Gil Medical Center, Seoul (Korea, Republic of)

    1999-06-01

    In the literature, descriptions of the MR findings of renal leiomyoma are rare. We present the MR findings of a capsular leiomyoma of the kidney in which hypointensity relative to normal renal parenchyma was seen on both T1-and T2-weighted MR images.

  8. MR imaging findings of renal capsular leiomyoma : a case report

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Jin Woo; Cho, Hyun I; Lee, Jong Bouk

    1999-01-01

    In the literature, descriptions of the MR findings of renal leiomyoma are rare. We present the MR findings of a capsular leiomyoma of the kidney in which hypointensity relative to normal renal parenchyma was seen on both T1-and T2-weighted MR images

  9. Systematic measurements of opacity dependence on temperature, density, and atomic number at stellar interior conditions

    Science.gov (United States)

    Nagayama, Taisuke

    2017-10-01

    Model predictions for iron opacity are notably different from measurements performed at matter conditions similar to the boundary between the solar radiation and convection zones. The calculated iron opacities have narrower spectral lines, weaker quasi-continuum at short wavelength, and deeper opacity windows than the measurements. If correct, these measurements help resolve a decade old problem in solar physics. A key question is therefore: What is responsible for the model-data discrepancy? The answer is complex because the experiments are challenging and opacity theories depend on multiple entangled physical processes such as the influence of completeness and accuracy of atomic states, line broadening, contributions from myriad transitions from excited states, and multi-photon absorption processes. To help determine the cause of this discrepancy, a systematic study of opacity variation with temperature, density, and atomic number is underway. Measurements of chromium, iron, and nickel opacities have been performed at two different temperatures and densities. The collection of measured opacities provides constraints on hypotheses to explain the discrepancy. We will discuss implications of measured opacities, experimental errors, and possible opacity model refinements. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

  10. Delayed splenic rupture: dating the sub-capsular hemorrhage as a useful task to evaluate causal relationships with trauma.

    Science.gov (United States)

    Riezzo, Irene; Di Battista, Benedetta; De Salvia, Alessandra; Cantatore, Santina; Neri, Margherita; Pomara, Cristoforo; Turillazzi, Emanuela; Fineschi, Vittorio

    2014-01-01

    The aim of the paper was to perform a chronological assessment of the phenomenon of delayed rupture of the spleen, to assess the phenomenological order about the sub-capsular hematoma transformation to determine the causal relationship with trauma as hypothetical cause of death. 80 cases of blunt trauma with splenic capsular hematoma and subsequent rupture of the spleen were evaluated: 38 had an acute rupture of the spleen, 42 presented a break in days or weeks after the traumatic injury. Time between the traumatic event and delayed rupture of the spleen is within a range of time from one day to more than one month. Data recorded included age, sex, type of trauma, injury severity score, grade of splenic injury, associated intra-abdominal injuries, pathologic specimen evaluation. Immunohistochemical investigation of perisplenic hematoma or laceration was performed utilizing polyclonal antibodies anti-fibrinogen, CD61 and CD68, and showed structural chronological differences of sub-capsular hematoma. Expression of modification and organization of erythrocytes, fibrinogen, platelets and macrophages provides an informative picture of the progression of reparative phenomena associated with sub-capsular hematoma and subsequent delayed splenic rupture. Sub-capsular splenic hematoma dating, which we divided into 4 phases, is representing a task in both clinical practice and forensic pathology. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Investigation of vesicle-capsular plague antigen complex formation by elastic laser radiation scattering

    Science.gov (United States)

    Guseva, N. P.; Maximova, Irina S.; Romanov, Sergey V.; Shubochkin, L. P.; Tatarintsev, Sergey N.

    1991-05-01

    Recently a great deal of attention has been given to the investigation artificial lipid liposomes, due to their application as "containers" for directed transport of biologically active compounds into particular cells, organs and tissues for prophylaxis and therapy of infectious diseases. The use of traditional methods of liposome investigation, such as sedimentation, electrophoresis and chromatography is impeded by low liposome resistivity to different deformations. In conjunction with this, optical methods of laser light scattering are promising as they allow nondisturbing, precise and quick investigations. This paper describes the investigation of vesicle systems prepared from egg lecithin of Serva Corporation and their complexes with the capsular antigen of the plague microbe. The capsular antigen Fl was obtained from EV plague microbe grown at 37° C on Huttinger agar. Fl was isolated by gel-filtration on ASA-22 followed by freeze drying of the preparation. Angular dependences of polarized radiation scattering were measured for several liposome suspension samples in a saline solution before and after the interaction with the plague microbe capsular antigen. The aim of the investigation was to analyze the nature of mutual antigen arrangement in a liposome and to develop methods for measuring its inclusion percentage.

  12. [Evaluation of the modified capsular tension ring in cases of traumatic lens subluxation].

    Science.gov (United States)

    Marques, Daniela Meira Villano; Marques, Frederico França; Cionni, Robert J; Osher, Robert Henry; Freitas, Lincoln Lemes

    2007-01-01

    To evaluate the behavior of the modified capsular tension ring (MCTR) in traumatic subluxated cataracts analyzing the visual acuity, centration of the capsular bag, pseudophacodonesis, postoperative follow-up and intra- and postoperative complications. Cincinnati Eye Institute, Cincinnati, Ohio, USA. Twenty-two eyes of 22 patients with traumatic loss of zonular support had phacoemulsification using PCIOL and MCTR implantation. The preoperative examination included best correct visual acuity (BCVA) and the presence or absence of phacodonesis, lens decentration and vitreous prolapse. The postoperative evaluation included BCVA, the presence of pseudophacodonesis, PCIOL centration, necessity of vitrectomy and other complications. 21 eyes (95.45%) had an improvement in BCVA. The preoperative examination disclosed phacodonesis in 11 eyes (50%) and no eye presented pseudophacodonesis in the postoperative period. Preoperatively, symptomatic decentration was presented by 10 eyes (45.45%) and 22 eyes (100%) had no decentration after surgery. The preoperative examination revealed vitreous prolapse in the anterior chamber in 9 eyes (40.90%). Vitrectomy was required in 11 eyes (50%). The use of the MCTR resulted in a good centration of the capsular bag and the PC IOL in 22 eyes with traumatic cataract and loss of zonular support.

  13. Retro-aortic, left inferior renal capsular vein

    Directory of Open Access Journals (Sweden)

    Umberto G Rossi

    2015-01-01

    Full Text Available In our case report, abdominal multi-detector computed tomography was used for the pre-operative anatomy evaluation in a living kidney donor. The early phase of the test revealed normal kidneys in the donor. The vascular phase detected a venous variant on the left side: An inferior renal capsular vein, which had a loop and a retro-aortic course. This preoperative knowledge was crucial for the laparoscopic nephrectomy as a surgical procedure for harvesting kidney from the living donor.

  14. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  15. Neutrino opacities and the pasta phase structure

    International Nuclear Information System (INIS)

    Menezes, D.P.; Alloy, M.D.

    2011-01-01

    The diffusion coefficients that are related to the neutrino opacities are calculated in such a way that the formation of nuclear pasta and homogeneous matter at low densities are taken into account. Two methods are developed to build the pasta phase and their differences are outlined. One of them is chosen as part of a complete equation of state used in the calculation of the diffusion coefficients. Our results show that the mean free paths are significantly altered by the presence of nuclear pasta in stellar matter when compared with the results obtained with pure homogeneous matter. These differences in neutrino opacities will have consequences in the calculation of the Kelvin-Helmholtz phase of protoneutron stars. (author)

  16. Do textured breast implants decrease the rate of capsular contracture compared to smooth implants?

    Science.gov (United States)

    Cifuentes, Ignacio; Dagnino, Bruno; Rada, Gabriel

    2017-08-31

    The use of breast implants for aesthetic and reconstructive purposes has become one of the most common procedures performed by plastic surgeons. Several breast implants models exist. They differ in their size, filling, shape and characteristic of the shell, which can be smooth or textured. Capsular contracture is one of the main complications of breast implants. It has been suggested that the use of textured implants could reduce the incidence of capsular contracture. To answer this question, we used Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We identified 15 studies overall, of which 13 were randomized trials relevant for the question of interest. We extracted data from the systematic reviews, reanalyzed data of primary studies, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. We concluded the use of textured breast implants probably decreases the risk of capsular contracture, however, they might be associated to an increased risk of anaplastic large cell lymphoma.

  17. A retrospective study of the indications and outcomes of capsular tension ring insertion during cataract surgery at a tertiary teaching hospital

    Directory of Open Access Journals (Sweden)

    Wang BZ

    2013-03-01

    Full Text Available Bob Z Wang, Elsie Chan, Rasik B Vajpayee The Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia; Centre for Eye Research Australia, University of Melbourne, East Melbourne, Victoria, Australia Background: The purpose was to determine preoperative indications, intraoperative procedures, and outcomes of capsular tension ring (CTR insertion during cataract surgery. Methods: A review of all patients undergoing cataract surgery with insertion of a CTR between July 2000 and June 2010 was conducted at The Royal Victorian Eye and Ear Hospital, a large tertiary teaching hospital in Victoria, Australia. Information relating to each patient's demographic details, preoperative assessment, surgical procedure, and postoperative assessment were obtained. Results: Eighty-four eyes of 82 patients were included in this study. The main indications for CTR insertion were previous trauma, pseudoexfoliation syndrome, and mature cataracts. Twenty-one eyes (25.0% did not have any obvious preoperative indication. A posterior capsule tear was the most common intraoperative complication (3.6%. An intraocular lens was successfully implanted in the bag in 72 eyes (85.7%. Postoperatively, the most common complications were a decentered intraocular lens (8.3% and persistent corneal edema (6.0%. Overall, 61 eyes (72.6% had better postoperative visual acuity compared with preoperative acuity, with 67 patients (79.8% achieving vision of 20/40 or better. Conclusion: For the majority of cases, CTR use in complex cataract surgeries is associated with improved postoperative outcomes. CTR implantation is most commonly required in patients with known risk factors for zonular instability. Keywords: capsular tension ring, cataract extraction, indications, outcomes

  18. Nuclear 'pasta phase' and its consequences on neutrino opacities

    International Nuclear Information System (INIS)

    Alloy, M. D.; Menezes, D. P.

    2011-01-01

    In this paper, we calculate the diffusion coefficients that are related to the neutrino opacities considering the formation of nuclear pasta and homogeneous matter at low densities. Our results show that the mean-free paths are significantly altered by the presence of nuclear pasta in stellar matter when compared with the results obtained with homogeneous matter. These differences in neutrino opacities certainly influence the Kelvin-Helmholtz phase of protoneutron stars and consequently the results of supernova explosion simulations.

  19. Application of capsular tension ring combined with iris hooks in phacoemulsification of traumatic cataract with lens subluxation

    Directory of Open Access Journals (Sweden)

    Li-Gang Li

    2015-07-01

    Full Text Available AIM: To evaluate the clinical efficacy and safety of capsular tension ring(CTRcombined with iris hooks in eyes with large traumatic zonular dialysis or weakness that underwent micro-incision coaxial phacoemulsification with posterior chamber(PCintraocular lens(IOLimplantation. METHODS: This prospective study was carried on 21 patients(21 eyeswith traumatic cataract and traumaticzonular dialysis(RESULTS: The mean follow-up period was 3~12mo. No serious postoperative complication was found. BCVA in our cases: 0.8 in 5 eyes. IOPs were in normal range too. The IOLs in 20 eyes remained the required position to the final follow-up examination except one eye in which the PC IOL was dislocated into vitreous cavity due to a postoperative spontaneity PCR, and in which vitrectomy and IOL suture fixation was performed.CONCLUSION: In cases of cataract associated with traumatic zonular dialysis(<180°, by setting the rational parameters of phacoemulsification, the CTR and iris hooks are found to be efficient in preventing IOL decentration and reducing operation complication. In our cases, the CTR combined with iris hooks is relatively safe application.

  20. Presenting a model for display and user interface specifications of web based OPACs on the basis of available universal standards and experts views in order to compare the Iranian library and information centers OPACs

    OpenAIRE

    Zavaraqi, Rasoul

    2005-01-01

    The aim of this study is to present a model for display and user interface specifications of web-based OPACs on the basis of available universal standards and experts’ views in order to compare the present Iranian library and information centers OPACs. Three method were used for data collection in this research: literature review, survey of opinions by means of a checklist, and evaluation of the available web-based OPACs. The community of Iranian experts in OPAC issues and all of 6 available ...

  1. The influence of urban area opacity on biologically active UV-B irradiance

    Science.gov (United States)

    Chubarova, Nataly; Rozental', Victor

    2013-04-01

    The study of UV irradiance changes in urban area is an essential problem due to the significant effect of UV irradiance on human health which can be positive (vitamin D synthesis) and negative (erythema, skin cancer, eye damage). According to the results of several experiments within the Moscow megacity we studied the effects of urban area opacity on the different types of biologically active UV-B irradiance on the base of a specially developed mobile photometric complex snd additional measurements of the urban opacity by Nikon Fisheye Converter FC-E8. We analyzed both the level of erythemally-active irradiance and the UV eye damaging radiation using the broadband UVB-1 YES pyranometer calibrated against ultraviolet spectroradiometer Bentham DTM-300 of the Medical University of Innsbruck (courtesy of Dr. M.Blumthaler). In order to estimate the effects of the urban opacity the measurements were normalized on similar measurements at the Meteorological Observatory of Moscow State University with zero opacity. This ratio is defined as an urban radiative transmittance (URT). Different atmospheric conditions were considered. In cloudy conditions the effect of opacity on URT is much less than that in conditions when the sun disk is open from clouds. We revealed some spectral features in transmittance of biologically active UV-B irradiance which is characterized by higher URT variations in overcast cloudy conditions due to more intensive scattering and smaller direct solar radiation component. In the absence of cloudiness the effect of opacity was studied for open and screening solar disk conditions. We obtained much higher URT in UVB spectral region compared with that for total solar irradiance for screening solar disk conditions with a significant URT dependence on the opacity only in UVB spectral region. No URT dependence was obtained for total solar irradiance in these conditions. Some model calculations were fulfilled to match the experimental results.

  2. Population-based study of capsular warning syndrome and prognosis after early recurrent TIA.

    Science.gov (United States)

    Paul, Nicola L M; Simoni, Michela; Chandratheva, Arvind; Rothwell, Peter M

    2012-09-25

    Many guidelines recommend emergency assessment for patients with ≥2 TIAs within 7 days, perhaps in recognition of the capsular warning syndrome. However, it is unclear whether all patients with multiple TIAs are at high early risk of stroke and whether treatable underlying pathologies are more prevalent in this group. We studied clinical characteristics, Trial of Org 10172 in Acute Stroke Treatment (TOAST) classification, and risk of stroke in 1,000 consecutive patients with incident and recurrent TIAs in a prospective, population-based study (Oxford Vascular Study). Of 1,000 patients with TIAs, 170 had a further TIA within 7 days (105 within 24 hours). Multiple TIAs were not associated with carotid stenosis or atrial fibrillation, and much of the 10.6 (95% confidence interval [CI] 6.5-15.9) risk of stroke during the 7 days after the first TIA was due to patients with small-vessel disease (SVD) etiology (10 of 24 vs 8 of 146, odds ratio [OR] = 12.3, 95% CI 3.7-41.9, p TIA was similar to the risk after a single TIA in patients with non-SVD TIA (8 of 146 [5.5%] vs 76 of 830 [9.2%], OR = 0.58, 95% CI 0.25-1.3, p = 0.20). Of the 9 patients with stroke after a capsular warning syndrome, all had the recurrent TIA within 24 hours after the first TIA, and the subsequent stroke occurred within 72 hours of the second TIA in 8. The ABCD2 scores of all preceding TIAs were ≥4 in all 9 patients with capsular warning syndrome before stroke. Capsular warning syndrome is rare (1.5% of TIA presentations) but has a poor prognosis (7-day stroke risk of 60%). Otherwise, recurrent TIA within 7 days is not associated with a greater stroke risk than that after a single TIA.

  3. A fully blanketed early B star LTE model atmosphere using an opacity sampling technique

    International Nuclear Information System (INIS)

    Phillips, A.P.; Wright, S.L.

    1980-01-01

    A fully blanketed LTE model of a stellar atmosphere with Tsub(e) = 21914 K (thetasub(e) = 0.23), log g = 4 is presented. The model includes an explicit representation of the opacity due to the strongest lines, and uses a statistical opacity sampling technique to represent the weaker line opacity. The sampling technique is subjected to several tests and the model is compared with an atmosphere calculated using the line-distribution function method. The limitations of the distribution function method and the particular opacity sampling method used here are discussed in the light of the results obtained. (author)

  4. Eficacia de la vacuna meningocócica de polisacárido capsular del grupo C

    OpenAIRE

    González Enríquez Jesús; García Comas Luis; Alcaide Jiménez Juan Francisco; Sáenz Calvo Antonio; Conde Olasagasti José

    1997-01-01

    FUNDAMENTO: Este trabajo consiste esencialmente en una revisión sistemática de la literatura científica sobre los efectos, intensidad y duración de la respuesta serológica, así como sobre la eficacia, efectividad y seguridad de la vacuna meningocócica de polisacárido capsular del grupo C. MÉTODOS: Búsqueda en repertorio MEDLINE en el periodo 1970-1996. Búsqueda específica de ensayos clínicos aleatorizados y estudios de intervención prospectivos en humanos con vacunas de polisacáridos capsular...

  5. Chronic neck pain: making the connection between capsular ligament laxity and cervical instability.

    Science.gov (United States)

    Steilen, Danielle; Hauser, Ross; Woldin, Barbara; Sawyer, Sarah

    2014-01-01

    The use of conventional modalities for chronic neck pain remains debatable, primarily because most treatments have had limited success. We conducted a review of the literature published up to December 2013 on the diagnostic and treatment modalities of disorders related to chronic neck pain and concluded that, despite providing temporary relief of symptoms, these treatments do not address the specific problems of healing and are not likely to offer long-term cures. The objectives of this narrative review are to provide an overview of chronic neck pain as it relates to cervical instability, to describe the anatomical features of the cervical spine and the impact of capsular ligament laxity, to discuss the disorders causing chronic neck pain and their current treatments, and lastly, to present prolotherapy as a viable treatment option that heals injured ligaments, restores stability to the spine, and resolves chronic neck pain. The capsular ligaments are the main stabilizing structures of the facet joints in the cervical spine and have been implicated as a major source of chronic neck pain. Chronic neck pain often reflects a state of instability in the cervical spine and is a symptom common to a number of conditions described herein, including disc herniation, cervical spondylosis, whiplash injury and whiplash associated disorder, postconcussion syndrome, vertebrobasilar insufficiency, and Barré-Liéou syndrome. When the capsular ligaments are injured, they become elongated and exhibit laxity, which causes excessive movement of the cervical vertebrae. In the upper cervical spine (C0-C2), this can cause a number of other symptoms including, but not limited to, nerve irritation and vertebrobasilar insufficiency with associated vertigo, tinnitus, dizziness, facial pain, arm pain, and migraine headaches. In the lower cervical spine (C3-C7), this can cause muscle spasms, crepitation, and/or paresthesia in addition to chronic neck pain. In either case, the presence of

  6. Experimental investigation of opacity models for stellar interior, inertial fusion, and high energy density plasmas

    International Nuclear Information System (INIS)

    Bailey, J. E.; Rochau, G. A.; Mancini, R. C.; Iglesias, C. A.; MacFarlane, J. J.; Golovkin, I. E.; Blancard, C.; Cosse, Ph.; Faussurier, G.

    2009-01-01

    Theoretical opacities are required for calculating energy transport in plasmas. In particular, understanding stellar interiors, inertial fusion, and Z pinches depends on the opacities of mid-atomic-number elements over a wide range of temperatures. The 150-300 eV temperature range is particularly interesting. The opacity models are complex and experimental validation is crucial. For example, solar models presently disagree with helioseismology and one possible explanation is inadequate theoretical opacities. Testing these opacities requires well-characterized plasmas at temperatures high enough to produce the ion charge states that exist in the sun. Typical opacity experiments heat a sample using x rays and measure the spectrally resolved transmission with a backlight. The difficulty grows as the temperature increases because the heating x-ray source must supply more energy and the backlight must be bright enough to overwhelm the plasma self-emission. These problems can be overcome with the new generation of high energy density (HED) facilities. For example, recent experiments at Sandia's Z facility [M. K. Matzen et al., Phys. Plasmas 12, 055503 (2005)] measured the transmission of a mixed Mg and Fe plasma heated to 156±6 eV. This capability will also advance opacity science for other HED plasmas. This tutorial reviews experimental methods for testing opacity models, including experiment design, transmission measurement methods, accuracy evaluation, and plasma diagnostics. The solar interior serves as a focal problem and Z facility experiments illustrate the techniques.

  7. Ultra-dense hot low Z line transition opacity simulations

    International Nuclear Information System (INIS)

    Sauvan, P.; Minguez, E.; Gil, J.M.; Rodriguez, R.; Rubiano, J.G.; Martel, P.; Angelo, P.; Schott, R.; Philippe, F.; Leboucher-Dalimier, E.; Mancini, R.; Calisti, A.

    2002-01-01

    In this work two atomic physics models (the IDEFIX code using the dicenter model and the code based on parametric potentials ANALOP) have been used to calculate the opacities for bound-bound transitions in hot ultra-dense, low Z plasmas. These simulations are in connection with experiments carried out at LULI during the last two years, focused on bound-bound radiation. In this paper H-like opacities for aluminum and fluorine plasmas have been simulated, using both theoretical models, in a wide range of densities and temperatures higher than 200 eV

  8. Direct MR-arthrography of the shoulder with maximum capsular distension for surgical planning

    International Nuclear Information System (INIS)

    Drescher, R.; Rothenburg, T. von; Koester, O.; Schmid, G.; Ludwig, J.

    2004-01-01

    Purpose: To evaluate the effectiveness of direct MR arthrography of the glenohumeral joint with maximum distension of the joint capsule in patients with glenohumeral instability for preoperative diagnosis and for determining the method of surgical intervention. Materials and Methods: MR arthrography of the shoulder joint was performed on a 1.5 T system in 38 patients. All patients suffered from anterior or bidirectional instability. Using a fluoroscopically guided posterior approach, a 1% dilution of dimeglumine gadopentetate (5 mmol Gd-DTPA/l) was injected until full capsular stretching was achieved. MR imaging protocol included fat-saturated transversal, oblique-coronal and oblique-sagittal T1-weighted spin-echo, T1-weighted 3-D and transversal T2-weighted Flash-2D. Results: MR imaging revealed significant capsule distention in 22 patients and ventral capsule defects in 9 patients. Labral lesions were depicted in 25 patients, bicipital tendon lesions in 4 patients and partial ruptures of the rotator cuff in 3 patients. 15 of the 38 patients underwent surgery. Areas of pathologic laxity of the glenohumeral capsule were correctly described in all cases. In 12 of 15 patients, the best method of intervention could be determined prospectively. In 3 of 15 patients, the necessary operation was overestimated. Regarding labral ruptures, MRI had a sensitivity of 88%, a specificity of 86%, and a diagnostic accuracy of 87%. (orig.)

  9. Ground-glass opacity in lung metastasis from adenocarcinoma of the stomach: a case report

    International Nuclear Information System (INIS)

    Jung, Mi Ran; Kim, Jeong Kon; Lee, Jin Seong; Song, Koun Sik; Lim, Tae Hwan

    2000-01-01

    Ground-glass opacity is a frequent but nonspecific finding seen on high-resolution CT scans of lung parenchyma. Histologically, this appearance is observed when thickening of the alveolar wall and septal interstitium is minimal or the alveolar lumen is partially filled with fluid, macrophage, neutrophils, or amorphous material. It has been shown that ground-glass opacity may be caused not only by an active inflammatory process but also by fibrotic processes. When a focal area of ground-glass opacity persists or increases in size, the possibility of neoplasm-bronchioloalveolar carcinoma or adenoma, or lymphoma, for example, should be considered. Diffuse nonsegmental ground-glass opacity in both lung fields was incidentally found on follow up abdominal CT in a stomach cancer patient and signet-ring cell-type metastatic lung cancer was confirmed by transbronchial lung biopsy. We report a case of diffuse ground-glass opacity seen in metastatic lung cancer from adenocarcinoma of the stomach. (author)

  10. Shoulder MR arthrography of the posterior labrocapsular complex in overhead throwers with pathologic internal impingement and internal rotation deficit

    International Nuclear Information System (INIS)

    Tuite, Michael J.; Petersen, Brian D.; Wise, Steven M.; Fine, Jason P.; Kaplan, Lee D.; Orwin, John F.

    2007-01-01

    To determine if overhead-throwing athletes with internal impingement pain and internal rotation deficit have thickening of the posterior inferior labrocapsular complex on MR arthrogram images. This study was approved and a waiver of consent granted by our institutional review board. Twenty-six overhead-throwing athletes with internal impingement pain and internal rotation deficit, and 26 controls who had undergone MR arthrograms, were retrospectively examined. The MR studies were combined and read in a blind fashion. On an axial image through the posteroinferior glenoid rim, the readers measured the labral length, capsule-labrum length, and the posterior recess angle. A t-test was used to determine statistical significance. The mean labral length was 4.9 mm [standard deviation (SD) 1.4 mm] for the controls, and 6.4 mm (SD 1.6 mm) for the athletes (P = 0.001). The mean capsule-labrum length was 5.4 mm (SD 2.1 mm) for the controls, and 8.8 mm (SD 2.9 mm) for the athletes (P < 0.001). The mean posterior recess angle measured 65 (SD 27 ) for the controls and 94 (SD 38 ) for the athletes (P = 0.002). Overhead-throwing athletes with internal impingement pain and internal rotation deficit tend to have a thicker labrum and a shallower capsular recess in the posterior inferior shoulder joint than do non-overhead-throwing athletes. In many, the posteroinferior capsule is also thickened. These MR findings should alert the radiologist to closely inspect the posterior cuff and posterosuperior labrum for the tears associated with internal impingement. (orig.)

  11. Shoulder MR arthrography of the posterior labrocapsular complex in overhead throwers with pathologic internal impingement and internal rotation deficit

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, Michael J; Petersen, Brian D; Wise, Steven M [University of Wisconsin Hospital and Clinics, Department of Radiology, Madison, WI (United States); Fine, Jason P [University of Wisconsin Hospital and Clinics, Department of Biostatistics, Madison, WI (United States); Kaplan, Lee D; Orwin, John F [University of Wisconsin Hospital and Clinics, Department of Orthopedic Surgery, Madison, WI (United States)

    2007-06-15

    To determine if overhead-throwing athletes with internal impingement pain and internal rotation deficit have thickening of the posterior inferior labrocapsular complex on MR arthrogram images. This study was approved and a waiver of consent granted by our institutional review board. Twenty-six overhead-throwing athletes with internal impingement pain and internal rotation deficit, and 26 controls who had undergone MR arthrograms, were retrospectively examined. The MR studies were combined and read in a blind fashion. On an axial image through the posteroinferior glenoid rim, the readers measured the labral length, capsule-labrum length, and the posterior recess angle. A t-test was used to determine statistical significance. The mean labral length was 4.9 mm [standard deviation (SD) 1.4 mm] for the controls, and 6.4 mm (SD 1.6 mm) for the athletes (P = 0.001). The mean capsule-labrum length was 5.4 mm (SD 2.1 mm) for the controls, and 8.8 mm (SD 2.9 mm) for the athletes (P < 0.001). The mean posterior recess angle measured 65 (SD 27 ) for the controls and 94 (SD 38 ) for the athletes (P = 0.002). Overhead-throwing athletes with internal impingement pain and internal rotation deficit tend to have a thicker labrum and a shallower capsular recess in the posterior inferior shoulder joint than do non-overhead-throwing athletes. In many, the posteroinferior capsule is also thickened. These MR findings should alert the radiologist to closely inspect the posterior cuff and posterosuperior labrum for the tears associated with internal impingement. (orig.)

  12. Target simulations with SCROLL non-LTE opacity/emissivity databases.

    Science.gov (United States)

    Klapisch, M.; Colombant, D.; Bar-Shalom, A.

    2001-10-01

    SCROLL[1], a collisional radiative model and code based on superconfigurations, is able to compute high Z non-LTE opacities and emissivities accurately and efficiently. It was used to create opacity/emissivity databases for Pd, Lu, Au on a 50 temperatures/80 densities grid. Incident radiation field was shown to have no effect on opacities in the case of interest, and was not taken into account. These databases were introduced in the hydrocode FAST1D[2]. SCROLL also gives an ionization temperature Tz which is used in FAST1D to obtain non-LTE corrections to the equation of state. Results will be compared to those of a previous version using Busquet’s algorithm[3]. Work supported by USDOE under a contract with NRL. [1] A. Bar-Shalom, J. Oreg and M. Klapisch, J. Quant. Spectrosc. Radiat. Transfer, 65, 43(2000). [2] J. H. Gardner, A. J. Schmitt, J. P. Dahlburg, C. J. Pawley, S. E. Bodner, S. P. Obenschain, V. Serlin and Y. Aglitskiy, Phys. Plasmas, 5, 1935 (1998). [3] M. Busquet, Phys. Fluids B, 5, 4191 (1993).

  13. Chronic and Intermittent Angle Closure Caused by In-The-Bag Capsular Tension Ring and Intraocular Lens Dislocation in Patients With Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Bochmann, Frank; Strümer, Jörg

    2017-11-01

    A subluxation or dislocation of the intraocular lens (IOL) is a well-known complication after cataract surgery in patients with pseudoexfoliation syndrome (PEX). Capsular tension rings (CTR) are frequently used to prevent postoperative complications caused by zonular weakness. Here we present a series of 7 cases, 2 with intermittent and 5 with acute angle closure caused by a combination of PEX-associated zonular weakness and a resulting unstable capsular bag-CTR-IOL complex. We describe the typical clinical course with elevated intraocular pressure, myopic shift, and shallowing of the anterior chamber in 7 patients with a new type of secondary angle closure. The diagnostic challenges and treatment options are discussed in detail. In all cases, the mechanism of angle closure identified by ultrasound biomicroscopy was an anterior dislocation of the peripheral iris by the capsular bag-CTR-IOL complex. The IOL was removed together with the capsular bag and the CTR and replaced by an iris-fixated IOL in all cases. We present a new type of secondary angle closure caused by an anterior dislocated capsular bag-CTR-IOL complex. The cause of both, this atypical presentation and the ineffectiveness of the laser peripheral iridotomy is the large diameter CTR. Therefore CTR implantation might also be the source of late postoperative complications. If a secondary angle closure associated with PEX and unstable capsular bag-CTR-IOL complex is encountered, IOL explantation and replacement by an iris-fixated IOL is a simple and effective treatment option.

  14. Time Patterns in Remote OPAC Use.

    Science.gov (United States)

    Lucas, Thomas A.

    1993-01-01

    Describes a transaction log analysis of the New York Public Library research libraries' OPAC (online public access catalog). Much of the remote searching occurred when the libraries were closed and was more evenly distributed than internal searching, demonstrating that remote searching could expand access and reduce peak system loads. (Contains…

  15. The effect of Livermore OPAL opacities on the evolutionary masses of RR Lyrae stars

    Science.gov (United States)

    Yi, Sukyoung; Lee, Young-Wook; Demarque, Pierre

    1993-01-01

    We have investigated the effect of the new Livermore OPAL opacities on the evolution of horizontal-branch (HB) stars. This work was motivated by the recent stellar pulsation calculations using the new Livermore opacities, which suggest that the masses of double-mode RR Lyrae stars are 0.1-0.2 solar mass larger than those based on earlier opacities. Unlike the pulsation calculations, we find that the effect of opacity change on the evolution of HB stars is not significant. In particular, the effect of the mean masses of RR Lyrae stars is very small, showing a decrease of only 0.01-0.02 solar mass compared to the models based on old Cox-Stewart opacities. Consequently, with the new Livermore OPAL opacities, both the stellar pulsation and evolution models now predict approximately the same masses for the RR Lyrae stars. Our evolutionary models suggest that the mean masses of the RR Lyrae stars are about 0.76 and about 0.71 solar mass for M15 (Oosterhoff group II) and M3 (group I), respectively. If (alpha/Fe) = 0.4, these values are decreased by about 0.03 solar mass. Variations of the mean masses of RR Lyrae stars with HB morphology and metallicity are also presented.

  16. Development on the National Ignition Facility of a High Energy Density Opacity Platform

    Energy Technology Data Exchange (ETDEWEB)

    Perry, Theodore Sonne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dodd, Evan S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeVolder, Barbara Gloria [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Johns, Heather Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cardenas, Tana [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Archuleta, Thomas Nick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kline, John L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Flippo, Kirk Adler [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vinyard, Natalia Sergeevna [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sherrill, Manolo Edgar [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wilde, Bernhard Heinz [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tregillis, Ian Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Urbatsch, Todd James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Douglas, Melissa Rae [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Heeter, R. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Liedahl, D. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wilson, B. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Iglesias, C. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schneider, M. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Martin, M. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); London, R. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ahmed, M. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thompson, N. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Emig, J. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zika, M. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Opachich, Y. P. [Nevada National Security Site (NNSS), NV (United States); King, J. A. [Nevada National Security Site (NNSS), NV (United States); Ross, P. W. [Nevada National Security Site (NNSS), NV (United States); Huffman, E. J. [Nevada National Security Site (NNSS), NV (United States); Knight, R. A. [Nevada National Security Site (NNSS), NV (United States); Koch, J. A. [Nevada National Security Site (NNSS), NV (United States); Pond, T. D. [Nevada National Security Site (NNSS), NV (United States); Craxton, R. S. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Zhang, R. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; McKenty, P. W. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Garcia, E. M. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Bailey, J. E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rochau, G. A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hansen, S. B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-02

    X-ray opacity is a crucial factor in all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in simulation codes for high-energy-density plasmas. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment for various mid-Z elements (Fe, Cr, Ni). These discrepancies raise doubts regarding the accuracy of the opacity models which are used in ICF and stewardship as well as in astrophysics. Therefore, a new experimental opacity platform has been developed on the National Ignition Facility (NIF), not only to verify the Z-machine experimental results, but also to extend the experiments to other temperatures and densities. Within the context of the national opacity strategy, the first NIF experiments were directed towards measuring the opacity of iron at a temperature of ~160 eV and an electron density of ~7xl021 cm-3(Anchor 1). The Z data agree with theory at these conditions, providing a reference point for validation of the NIF platform. Development shots on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule, and also a combined hohlraum, sample and laser drive able to produce iron plasmas at the desired conditions. Spectrometer qualification has been completed, albeit with additional improvements planned, and the first iron absorption spectra have now been obtained.

  17. A structural investigation of the capsular antigens of some Klebsiella and E. coli serotypes

    International Nuclear Information System (INIS)

    Parolis, L.A.S.

    1985-11-01

    The work described in this thesis forms part of a program concerned with the study of exocellular capsular polysaccharides of some Enterobacteriaceae. 1 H- and 13 C-n.m.r. spectroscopy have been used in this study. Klebsiella and Escherichia coli are of interest because they are often pathogenic to man; E. coli are commensal bacteria as well as opportunistic pathogens. The bacterial capsule is the first line of defence of the bacterial cell against attack by the host's immunological defences and administered antibiotics, and thus knowledge of its composition and characteristics is of importance in devising ways of combating infection by these organisms. The structure of the capsular polysaccharide has been investigated employing a combination of chemical and spectroscopic methods. Several oligo-saccharides were isolated and characterized by high resolution 1 H-n.m.r. spectroscopy and methylation analysis. The E. coli group of bacteria possesses seventy-four recognized polysaccharide capsules and the structures of approximately twenty percent of these have been reported. The emphasis of this research group is centered on the elucidation of the structures of E. coli capsules. The acidic capsular polysaccharide isolated from E. coli K9 has been investigated using the techniques of methylation analysis periodate oxidation, bacteriophage degradation and n.m.r. spectroscopy. This thesis however represents a transition period in the study of Enterobacteriaceae capsular polysaccharides and so includes the structure elucidation of two Klebsiella polysaccharides, that of the K14 and K68 serotypes, and one E. coli polysaccharide, that of the K9 serotype. Bacteriophage-borne enzyme degradations of Klebsiella K14 and E. coli K9 polysaccharides have been performed and are presented. The thesis also includes a comparative study of the 0-specific side-chains of the lipo-polysaccharides of E. coli 09 and 09a serogroups

  18. Transverse musculocutaneous gracilis flap for treatment of capsular contracture in tertiary breast reconstruction.

    Science.gov (United States)

    Pülzl, Petra; Huemer, Georg M; Schoeller, Thomas

    2015-02-01

    Capsular contracture is a common complication associated with implant-based breast reconstruction and augmentation leading to pain, displacement, and rupture. After capsulectomy and implant exchange, the problem often reappears. We performed 52 deepithelialized free transverse musculocutaneous gracilis (TMG) flaps in 33 patients for tertiary breast reconstruction or augmentation of small- and medium-sized breasts. The indications for implant removal were unnatural feel and emotion of their breasts with foreign body feel, asymmetry, pain, and sensation of cold. Anyway, most of the patients did not have a severe capsular contracture deformity. The TMG flap is formed into a cone shape by bringing the tips of the ellipse together. Depending on the contralateral breast, the muscle can also be shaped in an S-form to get more projection if needed. The operating time for unilateral TMG flap breast reconstruction or augmentation was on average 3 hours and for bilateral procedure 5 hours. One patient had a secondary revision of the donor site due to disruption of the normal gluteal fold. Eighty percent of the unilateral TMG flap reconstructions had a lipofilling procedure afterward to correct small irregularities or asymmetry. The advantages of the TMG flap such as short harvesting time, inconspicuous donor site, and the possibility of having a natural breast shape make it our first choice to treat capsular contracture after breast reconstruction and augmentation.

  19. Aplicación del Nd-YAG láser en pacientes con opacidad de cápsula posterior

    Directory of Open Access Journals (Sweden)

    Eldis Eliecer Rodríguez Morffi

    Full Text Available Objetivo: determinar el resultado visual de la capsulotomía posterior en los pacientes con opacidad de cápsula posterior. Métodos: estudio descriptivo, transversal en el centro oftalmológico de Port Mourant en Guyana, en el período comprendido entre marzo de 2009 hasta julio de 2010. Con un universo de 54 pacientes, operados de catarata por la técnica de Blumenthal de más de 6 meses de evolución, con opacidad de la cápsula posterior. Las variables estudiadas fueron: edad, sexo, tipo de opacidad, complicaciones en el acto quirúrgico y agudeza visual corregida antes y después del láser. Los datos se recogieron de los informes operatorios y las historias clínicas. Resultados: existió un predominio del sexo femenino con más de 60 años. El 50 % de los pacientes antes del tratamiento presentaban una agudeza visual corregida menor o igual a 20/60.El tipo de opacidad capsular más diagnosticada fue las perlas de Elschnig (68,5 %. Solamente el 16,7 % de los pacientes tuvieron complicaciones, entre ellas, la elevación transitoria de la presión intraocular fue la más frecuente. El 81,5 % de los pacientes a los que se le realizó la capsulotomía posterior alcanzaron una visión corregida de 20/20. Conclusión: la capsulotomía posterior con Nd-YAG láser es un valioso procedimiento para los pacientes con opacidad de la cápsula posterior que mejora ostensiblemente su agudeza visual, con una incidencia mínima de complicaciones.

  20. Detailed-term-accounting approximation calculations of the radiative opacity of aluminum plasmas: A systematic study

    International Nuclear Information System (INIS)

    Zeng Jiaolong; Yuan Jianmin

    2002-01-01

    The spectrally resolved radiative opacity and the Rosseland and Planck mean opacities are calculated by using the detailed-term-accounting approximation for aluminum plasmas with varieties of density and temperature. The results are presented along a 40 eV isothermal sequence, a 0.01 g/cm 3 isodense sequence, and a sequence with average ionization degree Z*∼7.13. Particular attention is given to the influence of the detailed treatment of spectral lines on the Rosseland mean opacity under different thermodynamical conditions. The results show that at densities of 0.004 g/cm 3 and higher, the opacities are not very sensitive to the spectral linewidth within a reasonable range. As examples, the Rosseland mean opacity, which is most sensitive to the detailed linewidth, at 40 eV and 0.004 g/cm 3 changes no more than 15%, when we change the electron impact spectral linewidth artificially by reducing it by 50% or increasing it twice, and at 40 eV and 0.1 g/cm 3 it changes less than 5%. For comparison, we also carried out calculations by using an average atom model. For the Rosseland mean opacities, the two models show quite large differences, in particular at low densities, while for the Planck mean opacities the results of the two models are much closer

  1. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses.

    Science.gov (United States)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-01

    To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses 101 patients aged 21-77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1-4), color homogeneity (Ehomo) and six-point color score of maximum elasticity (Ecol). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. A visual color pattern, Ehomo, Ecol and LOM scoring were significantly different between benign and malignant lesions under all color opacities (Pbreast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Limited capsular release and controlled manipulation under anaesthesia for the treatment of frozen shoulder.

    Science.gov (United States)

    Bidwai, Amit S; Mayne, Alistair Iw; Nielsen, Maryke; Brownson, Peter

    2016-01-01

    In light of recent interest in the cost-effectiveness of the treatment options available for frozen shoulder, we aimed to determine the results of limited anterior capsular release and controlled manipulation under anaesthesia (MUA) in the treatment of primary frozen shoulder in terms of patient-related outcomes measure, range of motion and re-intervention rates. This single-surgeon series included prospectively collected data on all patients undergoing capsular release with MUA from March 2011 until June 2013, with a minimum follow-up of 6 months from the index procedure. Outcome measures included pre- and postoperative Oxford Shoulder Score (OSS), range of motion and need for re-intervention. Fifty-four procedures were performed in 52 patients. Mean age 50 years (range 42 years to 59 years); male: female ratio = 11: 41. There was a highly statistically significant improvement in both pain and function modules of the OSS (p patients were diabetics. There was no significant difference in pre-operative and postoperative OSS or range of motion between the diabetic group and the non-diabetic groups. No patients required surgical re-intervention. A combination of limited capsular release and MUA for the treatment of primary frozen shoulder is a safe and effective procedure resulting in marked improvement in pain, function and range of motion.

  3. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hana; Youk, Ji Hyun, E-mail: jhyouk@yuhs.ac; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-15

    Purpose: To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses Materials and methods: 101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (E{sub homo}) and six-point color score of maximum elasticity (E{sub col}). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. Results: A visual color pattern, E{sub homo}, E{sub col} and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, E{sub col}, E{sub homo} and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and E{sub col} showed significantly higher AUC than E{sub homo}. In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, E{sub homo}, but no significant difference was found in E{sub col}. Conclusion: Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE.

  4. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses

    International Nuclear Information System (INIS)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-01-01

    Purpose: To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses Materials and methods: 101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (E homo ) and six-point color score of maximum elasticity (E col ). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. Results: A visual color pattern, E homo , E col and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, E col , E homo and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and E col showed significantly higher AUC than E homo . In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, E homo , but no significant difference was found in E col . Conclusion: Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE

  5. The effect of post-mastectomy radiation therapy on breast implants: Unveiling biomaterial alterations with potential implications on capsular contracture

    Energy Technology Data Exchange (ETDEWEB)

    Ribuffo, Diego; Lo Torto, Federico [Department of Plastic Surgery, “Sapienza” University of Rome, Viale del Policlinico 155, 00166 Rome (Italy); Giannitelli, Sara M. [Tissue Engineering Unit, Department of Engineering, Università Campus Bio-Medico di Roma, Via Álvaro del Portillo 21, 00128 Rome (Italy); Urbini, Marco; Tortora, Luca [Surface Analysis Laboratory, Department of Mathematics and Physics, University “Roma Tre”, Via della Vasca Navale 84, 00146 Rome (Italy); INFN — National Institute of Nuclear Physics, Section of Roma Tre, Via della Vasca Navale 84, 00146 Rome (Italy); Mozetic, Pamela; Trombetta, Marcella [Tissue Engineering Unit, Department of Engineering, Università Campus Bio-Medico di Roma, Via Álvaro del Portillo 21, 00128 Rome (Italy); Basoli, Francesco; Licoccia, Silvia [Department of Chemical Science and Technologies, University of Rome “Tor Vergata”, Via della Ricerca Scientifica 1, 00173 Rome (Italy); Tombolini, Vincenzo [Department of Radiation Oncology, “Sapienza” University of Rome, Viale del Policlinico 155, 00166 Rome (Italy); Spencer-Lorillard Foundation, Viale Regina Elena 291, 00161 Rome (Italy); Cassese, Raffaele [Department of Radiation Oncology, “Sapienza” University of Rome, Viale del Policlinico 155, 00166 Rome (Italy); Scuderi, Nicolò [Department of Plastic Surgery, “Sapienza” University of Rome, Viale del Policlinico 155, 00166 Rome (Italy); and others

    2015-12-01

    Post-mastectomy breast reconstruction with expanders and implants is recognized as an integral part of breast cancer treatment. Its main complication is represented by capsular contracture, which leads to poor expansion, breast deformation, and pain, often requiring additional surgery. In such a scenario, the debate continues as to whether the second stage of breast reconstruction should be performed before or after post-mastectomy radiation therapy, in light of potential alterations induced by irradiation to silicone biomaterial. This work provides a novel, multi-technique approach to unveil the role of radiotherapy in biomaterial alterations, with potential involvement in capsular contracture. Following irradiation, implant shells underwent mechanical, chemical, and microstructural evaluation by means of tensile testing, Attenuated Total Reflectance Fourier Transform InfraRed spectroscopy (ATR/FTIR), Scanning Electron Microscopy (SEM), high resolution stylus profilometry, and Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS). Our findings are consistent with radiation-induced modifications of silicone that, although not detectable at the microscale, can be evidenced by more sophisticated nanoscale surface analyses. In light of these results, biomaterial irradiation cannot be ruled out as one of the possible co-factors underlying capsular contracture. - Highlights: • The debate continues whether to perform breast reconstruction before or after PMRT. • Radiation therapy may alter implant material, concurring to capsular contracture. • In this work, irradiated implants were investigated by a multi-technique approach. • Radiation-induced alterations could be evidenced by ATR/FTIR and ToF-SIMS. • Reported alteration might represent a co-factor underlying capsular contracture.

  6. Study on the aqueous humor contents of IL-1β and IL-6 in rabbits after extracapsular extraction of lens

    International Nuclear Information System (INIS)

    Zhao Jun

    2007-01-01

    Objective: To explore the relationship between the development of posterior capsular opacification and the aqueous humor contents of IL-1β and IL-6 after extracapsular extraction of lens in rabbits. Methods: Extracapsular extraction of lens was performed in 30 New Zealand rabbits. Aqueous humor contents of IL-1β and IL-6 were repeatedly determined with RIA and ophthal-moscopic as well as slit-lamp examination were repeatedly performed to detect any posterior capsular opacification developed on dl, d3, 1w, 2w, 1 month, 3 month posteperatively. Results: The aqueous humor contents of IL-1β and IL-6 increased gradually after operation, reached the peak on d7-d14, then gradually returned to within normal range by 2nd or 3rd month. Beginning from one month post-operatively, posterior capsular opacification was observed in some rabbits. By the end of 3rd month, Grade I opacification was developed in 5 rabbits, Grade H in 9 rabbits with Grade III (fundus view obliterated) in 14 rabbits. Peak IL-1β and IL- 6 content values were positively correlated with grading of future opacification. Conclusion: IL-1β and IL-6 might play important roles in the development of posterior capsular opacification after lens extraction in rabbits. (authors)

  7. Clinical study of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes

    Directory of Open Access Journals (Sweden)

    Ru-Fa Meng

    2015-07-01

    Full Text Available AIM: To investigate the operation methods and clinical effects of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes.METHODS: During January 2012 to January 2014, foldable intraocular lens was implanted on 47 cases following lens-vitrectomy in residual capsular with traumatic eyes 3~6mo. Follow-up period was 6~12mo, averaged(8.21±2.63mo. RESULTS:All of 47 eyes had successful operation at one time, and position deviation was not appeared. The naked vision of the last postoperative follow-up was(0.44±0.19. Compared with best corrected visual acuity(0.41±0.23, and There was no significant difference between visual acuity of preoperative and last follow-up period(t=0.879, P=0.342. No severe complication was found. CONCLUSION: Secondary implantation of foldable intraocular lens is a safe and reliable method for correcting ametropia after lens-vitrectomy in residual capsular with traumatic eyes.

  8. The relationship between elastomer opacity, colorimeter beam size, and measured colorimetric response.

    Science.gov (United States)

    Rugh, E H; Johnston, W M; Hesse, N S

    1991-01-01

    The effect of opacity on the colorimetric responses of large-area and small-area colorimeters was determined using an elastomer intended for maxillofacial prosthetics use and containing various pigments at different concentrations. Opacity was determined by calculating the contrast ratio of 2-mm-thick specimens against black and white backings, using Kubelka-Munk analyses to correct for thickness and backing color variations. The measure of comparison of the two colorimeters was the relative difference in tristimulus reflectance, with the tristimulus reflectance of the large-area colorimeter as the basis of the relative difference. A significant quadratic relationship was found between contrast ratio and the relative difference in tristimulus reflectance. This relationship may be used to describe opacity without the need to make optical observations or measurements of a thin layer of material on contrasting backings. The small-area colorimeter produced color parameters that are a measure of the combined effects of both color and opacity. The importance of beam size considerations of optical measuring devices for translucent natural and prosthetic materials was emphasized.

  9. Histopathologic and immunohistochemical features of capsular tissue around failed Ahmed glaucoma valves.

    Directory of Open Access Journals (Sweden)

    Alka Mahale

    Full Text Available Impervious encapsulation around Ahmed glaucoma valve (AGV results in surgical failure raising intraocular pressure (IOP. Dysregulation of extracellular matrix (ECM molecules and cellular factors might contribute to increased hydraulic resistance to aqueous drainage. Therefore, we examined these molecules in failed AGV capsular tissue. Immunostaining for ECM molecules (collagen I, collagen III, decorin, lumican, chondroitin sulfate, aggrecan and keratan sulfate and cellular factors (αSMA and TGFβ was performed on excised capsules from failed AGVs and control tenon's tissue. Staining intensity of ECM molecules was assessed using Image J. Cellular factors were assessed based on positive cell counts. Histopathologically two distinct layers were visible in capsules. The inner layer (proximal to the AGV showed significant decrease in most ECM molecules compared to outer layer. Furthermore, collagen III (p = 0.004, decorin (p = 0.02, lumican (p = 0.01 and chondroitin sulfate (p = 0.02 was significantly less in inner layer compared to tenon's tissue. Outer layer labelling however was similar to control tenon's for most ECM molecules. Significantly increased cellular expression of αSMA (p = 0.02 and TGFβ (p = 0.008 was detected within capsular tissue compared to controls. Our results suggest profibrotic activity indicated by increased αSMA and TGFβ expression and decreased expression of proteoglycan (decorin and lumican and glycosaminoglycans (chondroitin sulfate. Additionally, we observed decreased collagen III which might reflect increased myofibroblast contractility when coupled with increased TGFβ and αSMA expression. Together these events lead to tissue dysfunction potentially resulting in hydraulic resistance that may affect aqueous flow through the capsular wall.

  10. Histopathologic and immunohistochemical features of capsular tissue around failed Ahmed glaucoma valves.

    Science.gov (United States)

    Mahale, Alka; Fikri, Fatma; Al Hati, Khitam; Al Shahwan, Sami; Al Jadaan, Ibrahim; Al Katan, Hind; Khandekar, Rajiv; Maktabi, Azza; Edward, Deepak P

    2017-01-01

    Impervious encapsulation around Ahmed glaucoma valve (AGV) results in surgical failure raising intraocular pressure (IOP). Dysregulation of extracellular matrix (ECM) molecules and cellular factors might contribute to increased hydraulic resistance to aqueous drainage. Therefore, we examined these molecules in failed AGV capsular tissue. Immunostaining for ECM molecules (collagen I, collagen III, decorin, lumican, chondroitin sulfate, aggrecan and keratan sulfate) and cellular factors (αSMA and TGFβ) was performed on excised capsules from failed AGVs and control tenon's tissue. Staining intensity of ECM molecules was assessed using Image J. Cellular factors were assessed based on positive cell counts. Histopathologically two distinct layers were visible in capsules. The inner layer (proximal to the AGV) showed significant decrease in most ECM molecules compared to outer layer. Furthermore, collagen III (p = 0.004), decorin (p = 0.02), lumican (p = 0.01) and chondroitin sulfate (p = 0.02) was significantly less in inner layer compared to tenon's tissue. Outer layer labelling however was similar to control tenon's for most ECM molecules. Significantly increased cellular expression of αSMA (p = 0.02) and TGFβ (p = 0.008) was detected within capsular tissue compared to controls. Our results suggest profibrotic activity indicated by increased αSMA and TGFβ expression and decreased expression of proteoglycan (decorin and lumican) and glycosaminoglycans (chondroitin sulfate). Additionally, we observed decreased collagen III which might reflect increased myofibroblast contractility when coupled with increased TGFβ and αSMA expression. Together these events lead to tissue dysfunction potentially resulting in hydraulic resistance that may affect aqueous flow through the capsular wall.

  11. Thick keratoconic cornea associated with posterior polymorphous corneal dystrophy.

    Science.gov (United States)

    Zaarour, K; Slim, E; Antoun, J; Waked, N

    2017-03-01

    We herein report a case of bilateral unusually thick non-edematous keratoconic corneas with associated endothelial features of posterior polymorphous corneal dystrophy (PPCD). We report the case of a 27-year-old myopic woman who presented for refractive surgery. Slit lamp exam showed bilateral corneal protrusion with diffuse deep stromal and endothelial vesicular opacities and small paracentral bands. Topography showed generalized advanced corneal steepening in both eyes with increased anterior and posterior central corneal elevations in comparison to the best fit sphere. Ultrasound pachymetry showed central corneal thickness of 605μm (RE) and 612μm (LE). On specular biomicroscopy, cell density of 2503 cells/mm 2 RE and 1526 cells/mm 2 LE with significant cellular pleomorphism and polymegathism were noted. Clinical and paraclinical findings together suggest the presence of simultaneous keratoconus and PPCD. The literature has suggested an association between PPCD and steep cornea. Moreover, many reports have also described cases of associated PPCD and keratoconus with characteristic thinning and ectasia, in comparison to the unusual thick corneas noted in our patient, despite the absence of edema. Identification of genetics factors is further needed to clarify this association. This case describes a patient whose corneas present features of both keratoconus and PPCD and is unique due to the presence of increased corneal thickness despite the absence of edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. The Impact of Breast Implant Location on the Risk of Capsular Contraction

    DEFF Research Database (Denmark)

    Egeberg, Alexander; Sørensen, Jens Ahm

    2016-01-01

    BACKGROUND: Although many theories exist, the etiology of capsular contraction (CC) development is still not known. Anatomic location has been suggested as a possible risk factor, but rates of CC development vary between studies, often with conflicting results. This study examines the risk develo...

  13. Streptococcus iniae cpsG alters capsular carbohydrate composition and is a cause of serotype switching in vaccinated fish.

    Science.gov (United States)

    Heath, Candice; Gillen, Christine M; Chrysanthopoulos, Panagiotis; Walker, Mark J; Barnes, Andrew C

    2016-09-25

    Streptococcus iniae causes septicaemia and meningitis in marine and freshwater fish wherever they are farmed in warm-temperate and tropical regions. Although serotype specific, vaccination with bacterins (killed bacterial cultures) is largely successful and vaccine failure occurs only occasionally through emergence of new capsular serotypes. Previously we showed that mutations in vaccine escapes are restricted to a limited repertoire of genes within the 20-gene capsular polysaccharide (cps) operon. cpsG, a putative UDP-galactose 4-epimerase, has three sequence types based on the insertion or deletion of the three amino acids leucine, serine and lysine in the substrate binding site of the protein. To elucidate the role of cpsG in capsular polysaccharide (CPS) biosynthesis and capsular composition, we first prepared isogenic knockout and complemented mutants of cpsG by allelic exchange mutagenesis. Deletion of cpsG resulted in changes to colony morphology and cell buoyant density, and also significantly decreased galactose content relative to glucose in the capsular polysaccharide as determined by GC-MS, consistent with epimerase activity of CpsG. There was also a metabolic penalty of cpsG knockout revealed by slower growth in complex media, and reduced proliferation in whole fish blood. Moreover, whilst antibodies raised in fish against the wild type cross-reacted in whole cell and cps ELISA, they did not cross-opsonise the mutant in a peripheral blood neutrophil opsonisation assay, consistent with reported vaccine escape. We have shown here that mutation in cpsG results in altered CPS composition and this in turn results in poor cross-opsonisation that explains some of the historic vaccination failure on fish farms in Australia. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  14. Web-based OPACs: Between Tradition and Innovation.

    Science.gov (United States)

    Moscoso, Purificacion; Ortiz-Repiso, Virginia

    1999-01-01

    Analyzes the change that Internet-based OPACs (Online Public Access Catalogs) have represented to the structure, administration, and maintenance of the catalogs, retrieval systems, and user interfaces. Examines the structure of databases and traditional principles that have governed systems development. Discusses repercussions of the application…

  15. Analysis of the capsular polysaccharide biosynthesis locus of Porphyromonas gingivalis and development of a K1-specific polymerase chain reaction-based serotyping assay

    NARCIS (Netherlands)

    Brunner, J.; Crielaard, W.; Winkelhoff A.J. van

    2008-01-01

    Background and Objective: Porphyromonas gingivalis is a gram-negative obligate anaerobe that is strongly associated with severe periodontitis. Previous reports showed an association of P. gingivalis capsular polysaccharide with virulence. The K1 capsular polysaccharide was found to be more

  16. Net technique for intraocular lens support in aphakia without capsular support.

    Science.gov (United States)

    De Novelli, Fernando José; Neto, Theodomiro Lourenço Garrido; de Sena Rabelo, Gabriel; Blumer, Marcel Eduardo; Suzuki, Ricardo; Ghanem, Ramon Coral

    2017-01-01

    This paper describes a modified surgical technique for intraocular lens implantation in aphakic eyes with no capsular support. Retrospective case series. Seventeen eyes of 17 aphakic patients with no capsule support underwent intraocular lens (IOL) implantation using a standardized technique in which a net was created at the ciliary sulcus plane with two threads forming a net pattern. The net was used as support for the IOL. Follow-up ranged from 6 to 38 months, with an average of 23 months. In all cases, the IOL was safely implanted and remained stable during the follow-up. In 16 eyes, the IOL remained well centered; in one eye, slight decentration was observed. Distance-corrected visual acuity improved by a mean of 4 lines, from 1.13 (LogMAR) to 0.52 (P = 0.01). This technique might be especially useful in cases of insufficient capsular support associated with tissue loss or iris atrophy. In these cases, iris fixation is not feasible; thus, the only surgical alternative is IOL scleral fixation.

  17. Comparison of Fe and Ni opacity calculations for a better understanding of pulsating stellar envelopes

    International Nuclear Information System (INIS)

    Gilles, D.; Turck-Chieze, S.; Loisel, G.; Piau, L.; Ducret, J.E.; Poirier, M.; Blenski, T.; Thais, F.; Blancard, C.; Cosse, P.; Faussurier, G.; Gilleron, F.; Pain, J.C.; Porcherot, Q.; Guzik, J.A.; Kilcrease, D.P.; Magee, N.H.; Harris, J.; Busquet, M.; Delahaye, F.; Zeippen, C.J.; Bastiani-Ceccotti, S.

    2011-01-01

    Opacity is an important ingredient of the evolution of stars. The calculation of opacity coefficients is complicated by the fact that the plasma contains partially ionized heavy ions that contribute to opacity dominated by H and He. Up to now, the astrophysical community has greatly benefited from the work of the contributions of Los Alamos, Livermore and the Opacity Project (OP). However unexplained differences of up to 50% in the radiative forces and Rosseland mean values for Fe have been noticed for conditions corresponding to stellar envelopes. Such uncertainty has a real impact on the understanding of pulsating stellar envelopes, on the excitation of modes, and on the identification of the mode frequencies. Temperature and density conditions equivalent to those found in stars can now be produced in laboratory experiments for various atomic species. Recently the photo-absorption spectra of nickel and iron plasmas have been measured during the LULI 2010 campaign, for temperatures between 15 and 40 eV and densities of similar to 3 mg/cm 3 . A large theoretical collaboration, the 'OPAC', has been formed to prepare these experiments. We present here the set of opacity calculations performed by eight different groups for conditions relevant to the LULI 2010 experiment and to astrophysical stellar envelope conditions. (authors)

  18. Recent status and supplementary review of lenticular opacities in proximally exposed A-bomb survivors

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Ophthalmic Hospital, Hiroshima (Japan)

    1978-04-01

    A review was made on the progress of lenticular opacities in proximally exposed A-bomb survivors on the basis of three experimental cases. A-bomb cataract is the first late effect of A-bomb radiation which appeared in A-bomb survivors and is the only disorder which can still be visualized at the present time. We have therefore continued to use this as one major evidence that A-bomb injuries have not been cured in spite of our for a complete ban of nuclear weapons. According to the findings of lenticular opacities of typical A-bomb cataract observed in experimental cases, there was in some cases after a latent period progression of opacities from several years to more than 10 years followed by a gradual decrease in opacities, whereas in some cases there was after a latent period a remarkable progress in opacities for several years followed by a marked decrease in the lesions. At the present time there is no evidence of progression and it appears that the progression has ceased. Incipient senile cataract which developed concurrently has completely no transitional relationship to A-bomb cataract and appears to progress slowly but steadily.

  19. Recent status and supplementary review of lenticular opacities in proximally exposed A-bomb survivors

    International Nuclear Information System (INIS)

    Sugimoto, Shigenori

    1978-01-01

    A review was made on the progress of lenticular opacities in proximally exposed A-bomb survivors on the basis of three experimental cases. A-bomb cataract is the first late effect of A-bomb radiation which appeared in A-bomb survivors and is the only disorder which can still be visualized at the present time. We have therefore continued to use this as one major evidence that A-bomb injuries have not been cured in spite of our for a complete ban of nuclear weapons. According to the findings of lenticular opacities of typical A-bomb cataract observed in experimental cases, there was in some cases after a latent period progression of opacities from several years to more than 10 years followed by a gradual decrease in opacities, whereas in some cases there was after a latent period a remarkable progress in opacities for several years followed by a marked decrease in the lesions. At the present time there is no evidence of progression and it appears that the progression has ceased. Incipient senile cataract which developed concurrently has completely no transitional relationship to A-bomb cataract and appears to progress slowly but steadily. (auth.)

  20. IRON OPACITY BUMP CHANGES THE STABILITY AND STRUCTURE OF ACCRETION DISKS IN ACTIVE GALACTIC NUCLEI

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yan-Fei [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Davis, Shane W. [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904-4325 (United States); Stone, James M. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States)

    2016-08-10

    Accretion disks around supermassive black holes have regions where the Rosseland mean opacity can be larger than the electron scattering opacity due to the large number of bound–bound transitions in iron. We study the effects of this iron opacity “bump” on the thermal stability and vertical structure of radiation-pressure-dominated accretion disks, utilizing three-dimensional radiation magnetohydrodynamic (MHD) simulations in the local shearing box approximation. The simulations self-consistently calculate the heating due to MHD turbulence caused by magneto-rotational instability and radiative cooling by using the radiative transfer module based on a variable Eddington tensor in Athena. For a 5 × 10{sup 8} solar mass black hole with ∼3% of the Eddington luminosity, a model including the iron opacity bump maintains its structure for more than 10 thermal times without showing significant signs of thermal runaway. In contrast, if only electron scattering and free–free opacity are included as in the standard thin disk model, the disk collapses on the thermal timescale. The difference is caused by a combination of (1) an anti-correlation between the total optical depth and the midplane pressure, and (2) enhanced vertical advective energy transport. These results suggest that the iron opacity bump may have a strong impact on the stability and structure of active galactic nucleus (AGN) accretion disks, and may contribute to a dependence of AGN properties on metallicity. Since this opacity is relevant primarily in UV emitting regions of the flow, it may help to explain discrepancies between observation and theory that are unique to AGNs.

  1. Models for the computation of opacity of mixtures

    International Nuclear Information System (INIS)

    Klapisch, Marcel; Busquet, Michel

    2013-01-01

    We compare four models for the partial densities of the components of mixtures. These models yield different opacities as shown on polystyrene, acrylic and polyimide in local thermodynamical equilibrium (LTE). Two of these models, the ‘whole volume partial pressure’ model (M1) and its modification (M2) are not thermodynamically consistent (TC). The other two models are TC and minimize free energy. M3, the ‘partial volume equal pressure’ model, uses equality of chemical potential. M4 uses commonality of free electron density. The latter two give essentially identical results in LTE, but M4’s convergence is slower. M4 is easily generalized to non-LTE conditions. Non-LTE effects are shown by the variation of the Planck mean opacity of the mixtures with temperature and density. (paper)

  2. Free-free opacity in dense plasmas with an average atom model

    International Nuclear Information System (INIS)

    Shaffer, Nathaniel R.; Ferris, Natalie G.; Colgan, James Patrick; Kilcrease, David Parker; Starrett, Charles Edward

    2017-01-01

    A model for the free-free opacity of dense plasmas is presented. The model uses a previously developed average atom model, together with the Kubo-Greenwood model for optical conductivity. This, in turn, is used to calculate the opacity with the Kramers-Kronig dispersion relations. Furthermore, comparisons to other methods for dense deuterium results in excellent agreement with DFT-MD simulations, and reasonable agreement with a simple Yukawa screening model corrected to satisfy the conductivity sum rule.

  3. OPAC systému ALEPH

    OpenAIRE

    Pačísková, Jana

    2010-01-01

    This bachelor thesis presents analysis and evaluation of online catalog of integrated library system ALEPH, which was made after studying Web OPAC manual of this system and gathering information from practical testing of catalogs of National Library of Czech Republic and Regional Library of Karlovy Vary. In the first chapter, there is introduced and defined Online Public Access Catalog and its main principles and also its history is presented. In next chapters, there are described features an...

  4. Efectividad del Nd- Yag láser en la capsulotomía posterior Effectiveness of Nd-Yag laser in posterior capsulotomy

    Directory of Open Access Journals (Sweden)

    Alina Pedroso Llanes

    2004-06-01

    Full Text Available Este trabajo se propuso determinar la efectividad del neodimio YAG láser (Nd-YAG láser en la realización de capsulotomía posterior a 150 pacientes (ojos operados de catarata senil o presenil en el centro de Microcirugía Ocular en Serie del Hospital Oftalmológico Docente "Ramón Pando Ferrer" en el período comprendido de febreroa diciembre de 1999. En este grupo se analizaron como variables la edad, sexo, raza, implante o no de lente intraocular, tipo de opacidad de cápsula posterior, agudeza visual con corrección pre y postratamiento, complicaciones encontradas, comportamiento de la presión intraocular, así como la energía empleada para realizar dicho proceder. Estos datos se analizaron a través de tablas de contingencias Chi cuadrado. Como resultado de esta investigación se encontró que el láser es altamente efectivo para el mejoramiento de la agudeza visual en los pacientes afectados de catarata secundaria (74,7 %. Se observó además aumento transitorio de la presión intraocular en las dos primeras horas posteriores al láser (60,7 %, y no se encontró ninguna complicación que afectara la visión de los ojos estudiadosThe aim of this paper was to determine the effectiveness of neodymium YAG laser (Nd-YAG laser on performing the posterior capsulotomy in 150 patients (eyes operated on of senile or presenile cataract at the Center of Serial Ocular Microsurgery (CSOM of "Ramón Pando Ferrer" Ophthalmological Teaching Hospital from February to December 1999. Age, sex, race, implantation or not of the intraocular lens (IOL, type of opacity of the posterior capsule, visual acuity with pre- and posttreatment correction (Avcc, complications found, behavior of the intraocular pressure (IOP, as well as the energy used to carry out such procedure, were analyzed. The Chi square contingency tables were used to this end. As a result of this research, it was found that the laser is highly effective for improving visual acuity in patients

  5. Short-term evaluation of arthroscopic management of tennis elbow; including resection of radio-capitellar capsular complex.

    Science.gov (United States)

    Babaqi, AbdulRahman A; Kotb, Mohammed M; Said, Hatem G; AbdelHamid, Mohamed M; ElKady, Hesham A; ElAssal, Maher A

    2014-06-01

    There has been controversy regarding the pathogenesis and treatment of lateral epicondylitis. Different surgical techniques for the treatment of lateral epicondylitis prescribed. The purpose of this study was to evaluate the short-term outcomes of arthroscopic management including resection of the radio-capitellar capsular complex, using different validated scores. In this study, arthroscopic resection of a capsular fringe complex was done beside debridement of the undersurface of Extensor Carpi Radialis Brevis (ECRB). Thirty-one patients with recalcitrant lateral epicondylitis for a minimum of 6 months had surgery. In all patients, a collar-like band of radio-capitellar capsular complex was found to impinge on the radial head and subluxate into the radio-capitellar joint with manipulation under direct vision. Outcomes were assessed using Mayo Elbow Performance Index (MEPI), the Patient-Rated Tennis Elbow Evaluation (PRTEE), and the Disability of the Arm, Shoulder, and Hand (DASH), beside visual analog scale (VAS) for pain and satisfaction criteria. After arthroscopic surgery, overall satisfaction was extremely positive, over the 31 patients, 93.5% of the patients are satisfied. The mean score for pain improved from 8.64 to 1.48 points. The total PRTEE improved from 55.53 to 10.39 points. The mean MEPI score was improved from 61.82 to 94.10 points. DASH score also improved from 24.46 to 4.81 points. All improvements are statistically significant (P < 0.05). Arthroscopic release of ECRB in patients with chronic lateral epicondylitis is a reproducible method with a marked improvement in function within a short period, with special consideration for resection of radio-capitellar capsular complex.

  6. An Alternative to EPA Method 9 -- Field Validation of the Digital Opacity Compliance System (DOCS)

    National Research Council Canada - National Science Library

    Rasmussen, Steve L; Stone, Daniel A

    2005-01-01

    The Digital Opacity Compliance System (DOCS) software translates images from a commercial digital camera into visual plume opacity measurements, and is proposed as an alternate reporting method to EPA Method 9...

  7. Opacity of financial information, adoption of international standards and legal origins

    Directory of Open Access Journals (Sweden)

    Renata Turola Takamatsu

    2017-10-01

    Full Text Available Purpose – The goal of this study was to investigate the relationship between the level of Earnings Opacity and a company’s informational environment, specifically considering accounting standards and the legal origins of the system. Design/methodology/approach – The sample consisted of publicly traded companies from 20 countries classified as emerging, based on agency Standard & Poor’s index. The sample included data from 2004 to 2013. In order to compare the indicators among the group of countries, taking into account their institutional characteristics, the Mann-Whitney test and the Kruskal-Wallis test were performed. Findings – The assessment of the informational environment measures’ behavior in emerging countries revealed that these measures were correlated, suggesting that, despite different behaviors, opacity proxies share information. The fact that earnings opacity was lower in countries that had already adopted international standards during the analyzed period was also observed. In the same sense, a higher level of income smoothing was detected in countries of French code law origins. Originality/value – This article contributes to the understanding of the relationship between the characteristics of an accounting informational environment and the levels of opacity of the information emitted by accounting. Thus, this article has helped managers, investors and regulators to understand users’ needs and how country-specific characteristics change their perspectives.

  8. Lens opacities in children of Belarus affected by the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Arinchin, A.N.; Ospennikova, L.A. [Research Clinical Institute of Radiation Medicine and Endocrinology, Ministry of Health, Republic of Belarus, Aksakovschina, Minsk (Belarus)

    1998-03-01

    Reports about the increase in cataracts among the Ukrainian population living in the region of the Chernobyl Atomic Power Plant have been met with certain skepticism. At the same time, American specialists do not exclude the possibility of radiation genesis of lensopathias revealed among the citizens of Ukraine at the result of complex joint clinic-epidemiological study conducted by American and Ukrainian specialists in 1991. The aim of the investigation was to study the frequency and character of lens opacities in children permanently residing in the contaminated territories of the Republic of Belarus with anomalous high coefficients of {sup 137}Cs radionuclides through the food chain. It is well known that radiation cataract is one of the direct effects of ionizing radiation. Organ of sight is highly radiosensitive. The most radio-vulnerable part of eye is lens in which cataract is developing in response to both external and internal exposure. In children, focal lens opacities are localized in embryonic nucleus, but in elderly people, alongside with embryonic nucleus, they are also localized in adult nucleus and cortical layers. Lens opacity is the result of biochemical changes occurring in it, and it is caused by lens fibers damage. Frequency of occurrence of lensopathias in children from the main group made 82.1% which is by 12.5% more than in the control, mostly due to opacities in both lenses. (J.P.N.)

  9. Lens opacities in children of Belarus affected by the Chernobyl accident

    International Nuclear Information System (INIS)

    Arinchin, A.N.; Ospennikova, L.A.

    1998-01-01

    Reports about the increase in cataracts among the Ukrainian population living in the region of the Chernobyl Atomic Power Plant have been met with certain skepticism. At the same time, American specialists do not exclude the possibility of radiation genesis of lensopathias revealed among the citizens of Ukraine at the result of complex joint clinic-epidemiological study conducted by American and Ukrainian specialists in 1991. The aim of the investigation was to study the frequency and character of lens opacities in children permanently residing in the contaminated territories of the Republic of Belarus with anomalous high coefficients of 137 Cs radionuclides through the food chain. It is well known that radiation cataract is one of the direct effects of ionizing radiation. Organ of sight is highly radiosensitive. The most radio-vulnerable part of eye is lens in which cataract is developing in response to both external and internal exposure. In children, focal lens opacities are localized in embryonic nucleus, but in elderly people, alongside with embryonic nucleus, they are also localized in adult nucleus and cortical layers. Lens opacity is the result of biochemical changes occurring in it, and it is caused by lens fibers damage. Frequency of occurrence of lensopathias in children from the main group made 82.1% which is by 12.5% more than in the control, mostly due to opacities in both lenses. (J.P.N.)

  10. Large Enhancement in High-Energy Photoionization of Fe XVII and Missing Continuum Plasma Opacity

    Science.gov (United States)

    Nahar, Sultana N.; Pradhan, Anil K.

    2016-06-01

    Aimed at solving the outstanding problem of solar opacity, and radiation transport plasma models in general, we report substantial photoabsorption in the high-energy regime due to atomic core photoexcitations not heretofore considered. In extensive R -matrix calculations of unprecedented complexity for an important iron ion Fe xvii (Fe16 + ), with a wave function expansion of 99 Fe xviii (Fe17 + ) LS core states from n ≤4 complexes (equivalent to 218 fine structure levels), we find (i) up to orders of magnitude enhancement in background photoionization cross sections, in addition to strongly peaked photo-excitation-of-core resonances not considered in current opacity models, and ii) demonstrate convergence with respect to successive core excitations. The resulting increase in the monochromatic continuum, and 35% in the Rosseland mean opacity, are compared with the "higher-than-predicted" iron opacity measured at the Sandia Z -pinch fusion device at solar interior conditions.

  11. Effects of adhesive used as modeling liquid on the stability of the color and opacity of composites.

    Science.gov (United States)

    Araujo, Fernanda Santos; Barros, Mellany Cristie Ramos; Santana, Márcia Luciana Carregosa; de Jesus Oliveira, Ludmila Smith; Silva, Paula Fernanda Damasceno; Lima, Giana da Silveira; Faria-E-Silva, André Luis

    2018-04-01

    This study evaluated the effects of adhesive type used as modeling liquid on the stability of the color and opacity of composites submitted to thermal cycling in staining solutions followed by a bleaching procedure. Thirty cylinder-shaped composite specimens (10 mm diameter × 1.5 mm thickness) were built using or not using (control) an adhesive (Adper Universal or Scotchbond Multipurpose) as the modeling liquid. After polishing procedures, the color and opacity were measured, and the specimens were submitted to 200 thermal cycles with 10 s of dwell time in baths of grape juice at 5°C, water at 37°C, and coffee at 55°C. Changes in opacity and color caused by the staining solutions were measured. Then, the specimens were bleached with 35% hydrogen peroxide for 45 minutes followed by color/opacity measurements. Data were analyzed by ANOVA and Tukey's test (α = 0.05). The use of modeling liquids did not affect the initial color and opacity of composite. Reduced changes to color (E 00  = 3.44) and opacity (+2.67%) were observed for specimens modeled using Adper Universal. Bleaching procedures reduced the color (E 00  = 1.9-3.8) and opacity (-2.3 to 3.1%) alterations caused by staining solutions but were unable to restore the values observed at baseline. The use of universal adhesive as modeling liquid significantly reduced the color and opacity changes caused by staining solutions, and the bleaching procedure partially re-established the opacity and color of the composites. This study evaluates whether using adhesive systems for modeling a composite affects the color and opacity changes caused by staining solutions followed by a bleaching procedure. The findings suggest that the use of a universal adhesive as modeling liquid can reduce the alterations in optical properties caused by staining solutions, and the application of high-concentrated hydrogen peroxide over the composite reduce the color changes without fully recover the initial color. © 2018

  12. Multimedia Visualizer: An Animated, Object-Based OPAC.

    Science.gov (United States)

    Lee, Newton S.

    1991-01-01

    Describes the Multimedia Visualizer, an online public access catalog (OPAC) that uses animated visualizations to make it more user friendly. Pictures of the system are shown that illustrate the interactive objects that patrons can access, including card catalog drawers, librarian desks, and bookshelves; and access to multimedia items is described.…

  13. A huge renal capsular leiomyoma mimicking retroperitoneal sarcoma

    Directory of Open Access Journals (Sweden)

    Lal Anupam

    2009-01-01

    Full Text Available A huge left renal capsular leiomyoma mimicking retroperitoneal sarcoma presented in a patient as an abdominal mass. Computed tomography displayed a large heterogeneous retro-peritoneal mass in the left side of the abdomen with inferior and medial displacement as well as loss of fat plane with the left kidney. Surgical exploration revealed a capsulated mass that was tightly adherent to the left kidney; therefore, total tumor resection with radical left nephrectomy was performed. Histopathology ultimately confirmed the benign nature of the mass. This is the largest leiomyoma reported in literature to the best of our knowledge.

  14. Do textured breast implants decrease the rate of capsular contracture compared to smooth implants?

    Directory of Open Access Journals (Sweden)

    Ignacio Cifuentes

    2017-08-01

    Full Text Available Resumen El uso de implantes mamarios con propósitos estéticos y reconstructivos se ha convertido en uno de los procedimientos más comunes realizados por los cirujanos plásticos. Existen diversos modelos de implantes mamarios, los cuales difieren en su tamaño, relleno, forma y característica de la envoltura, pudiendo ser lisa o texturizada. La contractura capsular es una de las principales complicaciones del uso de implantes mamarios y se ha planteado que las prótesis texturizadas podrían disminuir la incidencia de contractura capsular. Para responder esta pregunta utilizamos Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud a nivel mundial, la cual es mantenida mediante búsquedas en múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Identificamos cinco revisiones sistemáticas que en conjunto incluyen 15 estudios primarios, 13 de ellos correspondientes a ensayos aleatorizados pertinentes a la pregunta de interés. Extrajimos los datos desde las revisiones identificadas, reanalizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos tablas de resumen de los resultados utilizando el método GRADE. Concluimos que el uso de prótesis mamaria texturizada probablemente disminuye el riesgo de contractura capsular, sin embargo, podría asociarse a un aumento en el riesgo de linfoma anaplásico de células grandes.

  15. Conceptual design of initial opacity experiments on the national ignition facility

    Science.gov (United States)

    Heeter, R. F.; Bailey, J. E.; Craxton, R. S.; Devolder, B. G.; Dodd, E. S.; Garcia, E. M.; Huffman, E. J.; Iglesias, C. A.; King, J. A.; Kline, J. L.; Liedahl, D. A.; McKenty, P. W.; Opachich, Y. P.; Rochau, G. A.; Ross, P. W.; Schneider, M. B.; Sherrill, M. E.; Wilson, B. G.; Zhang, R.; Perry, T. S.

    2017-02-01

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative-convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures eV and electron densities 21~\\text{cm}-3$ . The iron will be probed using continuum X-rays emitted in a ps, diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, of the NIF beams deliver 500 kJ to the mm diameter hohlraum, and the remaining directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.

  16. Genomic Investigation Reveals Highly Conserved, Mosaic, Recombination Events Associated with Capsular Switching among Invasive Neisseria meningitidis Serogroup W Sequence Type (ST)-11 Strains.

    Science.gov (United States)

    Mustapha, Mustapha M; Marsh, Jane W; Krauland, Mary G; Fernandez, Jorge O; de Lemos, Ana Paula S; Dunning Hotopp, Julie C; Wang, Xin; Mayer, Leonard W; Lawrence, Jeffrey G; Hiller, N Luisa; Harrison, Lee H

    2016-07-03

    Neisseria meningitidis is an important cause of meningococcal disease globally. Sequence type (ST)-11 clonal complex (cc11) is a hypervirulent meningococcal lineage historically associated with serogroup C capsule and is believed to have acquired the W capsule through a C to W capsular switching event. We studied the sequence of capsule gene cluster (cps) and adjoining genomic regions of 524 invasive W cc11 strains isolated globally. We identified recombination breakpoints corresponding to two distinct recombination events within W cc11: A 8.4-kb recombinant region likely acquired from W cc22 including the sialic acid/glycosyl-transferase gene, csw resulted in a C→W change in capsular phenotype and a 13.7-kb recombinant segment likely acquired from Y cc23 lineage includes 4.5 kb of cps genes and 8.2 kb downstream of the cps cluster resulting in allelic changes in capsule translocation genes. A vast majority of W cc11 strains (497/524, 94.8%) retain both recombination events as evidenced by sharing identical or very closely related capsular allelic profiles. These data suggest that the W cc11 capsular switch involved two separate recombination events and that current global W cc11 meningococcal disease is caused by strains bearing this mosaic capsular switch. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  17. Iron and Nickel spectral opacity calculations in conditions relevant for pulsating stellar envelopes and experiments

    International Nuclear Information System (INIS)

    Gilles, D.; Turck-Chieze, S.; Busquet, M.; Thais, F.; Loisel, G.; Piau, L.; Ducret, J. E.; Blenski, T.; Blancard, C.; Cosse, P.; Faussurier, G.; Gilleron, F.; Pain, J. C.; Porcherot, Q.; Guzik, J. A.; Kilcrease, D. P.; Magee, N. H.; Harris, J.; Bastiani-Ceccotti, S.; Delahaye, F.; Zeippen, C. J.

    2013-01-01

    Seismology of stars is strongly developing. To address this question we have formed an international collaboration, OPAC, to perform specific experimental measurements, compare opacity calculations, and improve the opacity calculations in stellar codes [1]. We consider the following opacity codes: SCO, CASSANDRA, STA, OPAS, LEDCOP, OP, SCO-RCG. Their comparison has shown large differences for Fe and Ni in equivalent conditions of envelopes of type II supernova precursors, temperatures between 15 and 40 eV and densities of a few mg/cm 3 [2-4]. LEDCOP, OPAS, SCO-RCG structure codes and STA give similar results and differ from OP ones for the lower temperatures and for spectral interval values [3]. In this work we discuss the role of Configuration Interaction (CI) and the influence of the number of used configurations. We present and include in the opacity code comparisons new HULLAC-v9 calculations [5, 6] that include full CI. To illustrate the importance of this effect we compare different CI approximations (modes) available in HULLAC-v9 [7]. These results are compared to previous predictions and to experimental data. Differences with OP results are discussed. (authors)

  18. A modified-simple technique of removing the lens cortex during cataract surgery

    Directory of Open Access Journals (Sweden)

    Kyung Eun Han

    2017-01-01

    Full Text Available We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD, and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.

  19. A medically relevant capsular polysaccharide in Acinetobacter baumannii is a potential vaccine candidate.

    Science.gov (United States)

    Yang, Feng-Ling; Lou, Tze-Chi; Kuo, Shu-Chen; Wu, Wan-Ling; Chern, Jeffy; Lee, Yi-Tzu; Chen, Shui-Tsung; Zou, Wei; Lin, Nien-Tsung; Wu, Shih-Hsiung

    2017-03-07

    Concerns of Acinetobacter baumannii infection have increased due to the emergence of multi-drug resistance. In the present study, we determined the capsular polysaccharide (CPS) structure of A. baumannii SK44, a clinical isolate from Taiwan, to consist of pentasaccharide repeats. We found that CPS-induced antibody provided 55% protection against challenge in an animal model. The CPS-specific antibody reacted with the surface components of about 62% clinical isolates (342/554 strains) from cross-sectional and longitudinal studies by dot-immunoassay. Pulsed-field gel electrophoresis of positive strains showed the antibody covered different clonalites of A. baumannii clinical isolates. Meanwhile, using the CPS antibody as a probe, we found a number of outer membrane proteins bound to the antibody, including OmpA/motB, TonB-dependent receptor, and Omp38, indicating their association with CPS. These results might lead to the use of the capsular polysaccharide as a vaccine to prevent A. baumannii infection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. GASEOUS MEAN OPACITIES FOR GIANT PLANET AND ULTRACOOL DWARF ATMOSPHERES OVER A RANGE OF METALLICITIES AND TEMPERATURES

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, Richard S. [SETI Institute, Mountain View, CA (United States); Lustig-Yaeger, Jacob [Department of Physics, University of California, Santa Cruz, CA 95064 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Lupu, Roxana E.; Marley, Mark S. [Space Science and Astrobiology Division, NASA Ames Research Center, Moffett Field, CA (United States); Lodders, Katharina, E-mail: Richard.S.Freedman@nasa.gov [Planetary Chemistry Laboratory, Washington University, St. Louis, MO (United States)

    2014-10-01

    We present new calculations of Rosseland and Planck gaseous mean opacities relevant to the atmospheres of giant planets and ultracool dwarfs. Such calculations are used in modeling the atmospheres, interiors, formation, and evolution of these objects. Our calculations are an expansion of those presented in Freedman et al. to include lower pressures, finer temperature resolution, and also the higher metallicities most relevant for giant planet atmospheres. Calculations span 1 μbar to 300 bar, and 75-4000 K, in a nearly square grid. Opacities at metallicities from solar to 50 times solar abundances are calculated. We also provide an analytic fit to the Rosseland mean opacities over the grid in pressure, temperature, and metallicity. In addition to computing mean opacities at these local temperatures, we also calculate them with weighting functions up to 7000 K, to simulate the mean opacities for incident stellar intensities, rather than locally thermally emitted intensities. The chemical equilibrium calculations account for the settling of condensates in a gravitational field and are applicable to cloud-free giant planet and ultracool dwarf atmospheres, but not circumstellar disks. We provide our extensive opacity tables for public use.

  1. Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities

    Science.gov (United States)

    Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner

    2014-09-01

    The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.

  2. Sonographic anatomy of the newborn hip and high-resolution US equipments: internal capsular stripe and perichondral gap

    International Nuclear Information System (INIS)

    Ortore, P.; Fodor, G.; Psenner, F.; Stuefert, S.; Scherer, M.

    1991-01-01

    The use of high-resolution US equipments in the examination of the newborn hip allowed the evaluation of a thin echogenic stripe (the internal capsule stripe), which defines laterally the acetabular hyaline cartilage. By means of an anatomo-histological preparation the echogenic stripe can be related to either the capsular circular fibres or the interface between the latter and the hyaline cartilage. The internal capsular stripe, together with the echogenic synovial stripe, precisely delimit the whole acetabular hyaline cartilage. Further-more, in many babies high-resolution US sometimes fails to demonstrate Graft's 'perichondral gap', so that an accurate anatomic knowledge of the hip becomes necessary in the evaluation of acetabular labrum

  3. UTILITARIAN OPACITY MODEL FOR AGGREGATE PARTICLES IN PROTOPLANETARY NEBULAE AND EXOPLANET ATMOSPHERES

    International Nuclear Information System (INIS)

    Cuzzi, Jeffrey N.; Davis, Sanford S.; Estrada, Paul R.

    2014-01-01

    As small solid grains grow into larger ones in protoplanetary nebulae, or in the cloudy atmospheres of exoplanets, they generally form porous aggregates rather than solid spheres. A number of previous studies have used highly sophisticated schemes to calculate opacity models for irregular, porous particles with sizes much smaller than a wavelength. However, mere growth itself can affect the opacity of the medium in far more significant ways than the detailed compositional and/or structural differences between grain constituents once aggregate particle sizes exceed the relevant wavelengths. This physics is not new; our goal here is to provide a model that provides physical insight and is simple to use in the increasing number of protoplanetary nebula evolution and exoplanet atmosphere models appearing in recent years, yet quantitatively captures the main radiative properties of mixtures of particles of arbitrary size, porosity, and composition. The model is a simple combination of effective medium theory with small-particle closed-form expressions, combined with suitably chosen transitions to geometric optics behavior. Calculations of wavelength-dependent emission and Rosseland mean opacity are shown and compared with Mie theory. The model's fidelity is very good in all comparisons we have made except in cases involving pure metal particles or monochromatic opacities for solid particles with sizes comparable to the wavelength

  4. Propuesta metodológica de evaluación de interfaces de OPACs. INNOPAC versus UNICORN.

    Directory of Open Access Journals (Sweden)

    Rodríguez Bravo, Blanca

    2004-03-01

    Full Text Available The aim of this paper is to present a model of academic OPACs evaluation with the objective of sharing a procedure and some parameters and indicators established. There are two fundamental parameters, the interface searching services and the characteristics of the interface: design, ergonomics and user-friendliness. The present work provides also, the main results of the evaluations of ten OPACs implemented with INNOPAC and UNICORN previously accomplished. Now we will contrast both systems. We consider that universities are institutions that demand OPACs with better services to those of other informative units. The present evaluation has considered the users needs in academic libraries.

    Los propósitos de este trabajo son presentar un modelo de evaluación de OPACs universitarios con el objetivo de compartir un procedimiento y unos parámetros e indicadores establecidos a este fin. Dos son los parámetros fundamentales, las prestaciones de búsqueda de la interfaz y las características de la propia interfaz: diseño, ergonomía y amigabilidad. El presente estudio ofrece, asimismo, los principales resultados de las evaluaciones realizadas en trabajos previos sobre diez OPACs implementados con INNOPAC y UNICORN, que nos permiten ahora contrastar ambos sistemas. Partimos de la consideración de que las universidades son instituciones que por su idiosincrasia exigen OPACs con prestaciones superiores a las de otras unidades informativas. En este sentido, la formalización de los criterios evaluativos ha considerado las necesidades de los usuarios de las bibliotecas universitarias.

  5. The solar elemental abundances problem: Large enhancements in photoionization and bound-free opacity

    Science.gov (United States)

    Pradhan, A.; Nahar, S.

    2016-05-01

    Aimed at solving the outstanding problem of solar opacity and radiation transport, we report substantial photoabsorption in the high-energy regime due to atomic core photo-excitations not heretofore considered. In an extensive R-Matrix calculations of unprecedented complexity for an important iron ion Fe XVII, with a wave function expansion of 99 Fe XVIII core states from n current opacity models, and ii) demonstrate convergence with respect to successive core excitations. These findings may explain the ``higher-than-predicted'' monochromatic iron opacity measured recently at the Sandia Z-pinch fusion device at solar interior conditions. The findings will also impact the total atomic photoabsorption and radiation transport in laboratory and astrophysical plasmas, such as UV emission from host stars of extra-solar planets. Support: NSF, DOE, Ohio Supercomputer Center, Columbus, OH.

  6. Comparative genome analysis of novel Podoviruses lytic for hypermucoviscous Klebsiella pneumoniae of K1, K2, and K57 capsular types.

    Science.gov (United States)

    Solovieva, Ekaterina V; Myakinina, Vera P; Kislichkina, Angelina A; Krasilnikova, Valentina M; Verevkin, Vladimir V; Mochalov, Vladimir V; Lev, Anastasia I; Fursova, Nadezhda K; Volozhantsev, Nikolay V

    2018-01-02

    Hypermucoviscous (HV) strains of capsular types K1, K2 and K57 are the most virulent representatives of the Klebsiella pneumoniae species. Eight novel bacteriophages lytic for HV K. pneumoniae were isolated and characterized. Three bacteriophages, KpV41, KpV475, and KpV71 were found to have a lytic activity against mainly K. pneumoniae of capsular type K1. Two phages, KpV74, and KpV763 were lytic for K2 capsular type K. pneumoniae, and the phage KpV767 was specific to K57-type K. pneumoniae only. Two more phages, KpV766, and KpV48 had no capsular specificity. The phage genomes consist of a linear double-stranded DNA of 40,395-44,623bp including direct terminal repeats of 180-246 bp. The G + C contents are 52.3-54.2 % that is slightly lower than that of genomes of K. pneumoniae strains being used for phage propagation. According to the genome structures, sequence similarity and phylogenetic data, the phages are classified within the genus Kp32virus and Kp34virus of subfamily Autographivirinae, family Podoviridae. In the phage genomes, genes encoding proteins with putative motifs of polysaccharide depolymerase were identified. Depolymerase genes of phages KpV71 and KpV74 lytic for hypermucoviscous K. pneumoniae of K1 and K2 capsular type, respectively, were cloned and expressed in Escherichia coli, and the recombinant gene products were purified. The specificity and polysaccharide-degrading activity of the recombinant depolymerases were demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Tropomyosin 2 heterozygous knockout in mice using CRISPR-Cas9 system displays the inhibition of injury-induced epithelial-mesenchymal transition, and lens opacity

    Science.gov (United States)

    Shibata, Teppei; Shibata, Shinsuke; Ishigaki, Yasuhito; Kiyokawa, Etsuko; Ikawa, Masahito; Singh, Dhirendra P.; Sasaki, Hiroshi; Kubo, Eri

    2018-01-01

    The process of epithelial–mesenchymal transition (EMT) of lens epithelial cells (LECs) after cataract surgery contributes to tissue fibrosis, wound healing and lens regeneration via a mechanism not yet fully understood. Here, we show that tropomyosin 2 (Tpm2) plays a critical role in wound healing and lens aging. Posterior capsular opacification (PCO) after lens extraction surgery was accompanied by elevated expression of Tpm2. Tpm2 heterozygous knockout mice, generated via the clustered regularly interspaced short palindromic repeat/ Cas9 (CRISPR/Cas9) system showed promoted progression of cataract with age. Further, injury-induced EMT of the mouse lens epithelium, as evaluated histologically and by the expression patterns of Tpm1 and Tpm2, was attenuated in the absence of Tpm2. In conclusion, Tpm2 may be important in maintaining lens physiology and morphology. However, Tpm2 is involved in the progression of EMT during the wound healing process of mouse LECs, suggesting that inhibition of Tpm2 may suppress PCO. PMID:29510160

  8. Light element opacities of astrophysical interest from ATOMIC

    Energy Technology Data Exchange (ETDEWEB)

    Colgan, J.; Kilcrease, D. P.; Magee, N. H. Jr.; Armstrong, G. S. J.; Abdallah, J. Jr.; Sherrill, M. E. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Fontes, C. J.; Zhang, H. L.; Hakel, P. [Computational Physics Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-07-11

    We present new calculations of local-thermodynamic-equilibrium (LTE) light element opacities from the Los Alamos ATOMIC code for systems of astrophysical interest. ATOMIC is a multi-purpose code that can generate LTE or non-LTE quantities of interest at various levels of approximation. Our calculations, which include fine-structure detail, represent a systematic improvement over previous Los Alamos opacity calculations using the LEDCOP legacy code. The ATOMIC code uses ab-initio atomic structure data computed from the CATS code, which is based on Cowan's atomic structure codes, and photoionization cross section data computed from the Los Alamos ionization code GIPPER. ATOMIC also incorporates a new equation-of-state (EOS) model based on the chemical picture. ATOMIC incorporates some physics packages from LEDCOP and also includes additional physical processes, such as improved free-free cross sections and additional scattering mechanisms. Our new calculations are made for elements of astrophysical interest and for a wide range of temperatures and densities.

  9. [Glycosaminoglycans in subepithelial opacity after excimer laser keratectomy].

    Science.gov (United States)

    Nakayasu, K; Gotoh, T; Ishikawa, T; Kanai, A

    1996-05-01

    We evaluated histochemically the characteristics of glycosaminoglycans and proteoglycans in the corneal subepithelial opacity after excimer laser keratectomy on rabbit corneas. We also performed the same evaluations on the cornea after mechanical keratectomy. Twenty days after the operations, the area immediately subjacent to the epithelium showed strong staining with toluidine blue, alcian blue, and colloidal iron. However, after treatment with chondroitinase ABC or chondroitinase AC, alcian blue staining in this area decreased dramatically. Antilarge proteoglycan antibody also reacted strongly in this area. Histochemical and immunohistochemical examination of the cornea where mechanical keratectomy was done showed basically similar findings with the cornea of excimer laser keratectomy. These results suggest that large-molecula proteoglycans with chondroitine sulfate side chains become localized in the subepithelial area after two different kinds of keratectomies. We presume from histochemical and immunohistochemical observations that the subepithelial opacity observed after excimer laser keratectomy is not a special reaction to excimer laser but simply a corneal scar formed after stromal resection.

  10. Different Accumulation Profiles of Multiple Components Between Pericarp and Seed of Alpinia oxyphylla Capsular Fruit as Determined by UFLC-MS/MS

    OpenAIRE

    Chen, Feng; Li, Hai-Long; Tan, Yin-Feng; Guan, Wei-Wei; Zhang, Jun-Qing; Li, Yong-Hui; Zhao, Yuan-Sheng; Qin, Zhen-Miao

    2014-01-01

    Plant secondary metabolites are known to not only play a key role in the adaptation of plants to their environment, but also represent an important source of active pharmaceuticals. Alpinia oxyphylla capsular fruits, made up of seeds and pericarps, are commonly used in traditional East Asian medicines. In clinical utilization of these capsular fruits, inconsistent processing approaches (i.e., hulling pericarps or not) are employed, with the potential of leading to differential pharmacological...

  11. Opacity and atomic analysis of double pulse laser ablated Li plasma

    Science.gov (United States)

    Sivakumaran, V.; Joshi, H. C.; Kumar, Ajai

    2014-09-01

    Opacity effects for neutral and ionic emission lines of lithium have been investigated by Atomic Data Analysis Structure (ADAS). Line ratios and opacity corrected photon emissivity coefficients are calculated over a wide range of electron temperatures and densities. The experimentally measured temporal evolution of the line profiles of the over dense Li plasma formed in the double pulse laser ablation experiment have been explained using the ADAS analysis and the plasma parameters of the plasma plume under consideration have been estimated. These results could be projected as a diagnostic tool to estimate plasma parameters of an over dense lithium plasma.

  12. Is the lateral radiograph necessary for the management of intra-capsular proximal femoral fractures?

    International Nuclear Information System (INIS)

    Korim, Muhammad Tawfiq; Mohan Reddy, Venthurla Ram; Gibbs, David; Wildin, Clare

    2012-01-01

    Aims: To investigate if a lateral hip radiograph is always needed in the management of intra-capsular proximal femoral fractures. Furthermore, we sought to evaluate if a radiographer could accurately identify cases in which the lateral radiograph is not required. Methods: All patients who underwent surgical management of an intra-capsular proximal femoral fracture over a 3 month period at our unit were identified. Radiographs were reviewed by 6 observers: 2 consultant orthopaedic surgeons, 2 registrars, and 2 radiographers. Initially the observers viewed the AP radiographs alone and classified the fractures into displaced, undisplaced, or unclear categories. They were then shown the lateral view and asked for a diagnosis and management plan. Comparison of diagnosis and management based on AP views alone, and AP in-combination with a lateral view was made. Results: 90 patients were included; the mean age was 80.8 years with a range of 42–100 years. 73 underwent arthroplasty and 17 had internal fixation. All observers, including the radiographer were able to make a surgical decision in 90% of the cases based on AP views alone. Lateral radiographs improved the diagnostic accuracy by 6%. The availability of the lateral view did not alter the management in patients where the AP clearly demonstrated a displaced fracture. Conclusion: Elderly patients with a displaced intra-capsular fracture identifiable on the AP do not require a lateral radiograph. Such patients can be accurately identified by the radiographer. Patient discomfort experienced during positioning for the lateral view would be avoided, and a financial saving made.

  13. Posterior vitreous detachment and retinal detachment after cataract surgery.

    Science.gov (United States)

    Ripandelli, Guido; Coppé, Andrea Maria; Parisi, Vincenzo; Olzi, Diego; Scassa, Cecilia; Chiaravalloti, Adele; Stirpe, Mario

    2007-04-01

    To evaluate possible changes of vitreous status in emmetropic eyes after uneventful phacoemulsification surgery, and possible related complications such as the onset of retinal detachment (RD). Retrospective case series. Four hundred fifty-three emmetropic eyes from 453 patients (mean age, 62.03+/-5.57 years) subjected to uneventful phacoemulsification with intraocular lens implantation in the capsular bag were considered in the study. They had a refractive error within +/-0.5 diopters (mean, -0.21+/-0.08). Eyes with peripheral retinal lattice degeneration were included only if asymptomatic and only if the degeneration involved one retinal quadrant. After cataract surgery, the 453 eyes were evaluated preoperatively at days 1, 15, and 30 and months 3, 6, 12, 18, 24, 36, 48, and 60. The whole period of follow-up was 5 years. Evaluation of vitreous status by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography. Postoperative onset of posterior vitreous detachment (PVD) and RD. After cataract surgery, a PVD occurred in 107 of 141 (75.88%) eyes without preoperative PVD or lattice degeneration. Posterior vitreous detachment occurred in 41 of 47 eyes (87.23%) with preoperative lattice degeneration and no PVD. Eyes with preoperative lattice degeneration and postoperative PVD showed a higher incidence of RD after cataract surgery (21.27%) than eyes without preoperative PVD or lattice degeneration (0.70%). In all patients with lattice degeneration, RD originated from horseshoe retinal tears on lattice areas located on the superior quadrants. No correlation was observed between the development of RD and age. Our results suggest that the onset of postoperative PVD should be considered an important risk factor for the development of RD after cataract surgery, particularly in eyes with lattice areas.

  14. Intralenticular foreign bodies: Report of eight cases and review of management

    Directory of Open Access Journals (Sweden)

    Arora Ritu

    2000-01-01

    Full Text Available Purpose: The management of intralenticular foreign bodies (ILFBs with or without cataract has varied from time to time in the last century. We evaluated the surgical removal of the ILFBs with cataract extraction as a single-stage procedure. Methods: Eight consecutive cases with intralenticular foreign bodies presenting to the trauma centre at our institute, were included in the study. Planned ILFB removal with cataract extraction and IOL implantation as a single-stage procedure was done in all the patients. They were followed up from 2 months to 2 years after the surgery. Results: ILFBs were removed with Kelman-Mcpherson forceps in seven cases and in one it was expressed with the nucleus during extra capsular cataract extraction. Co-existent posterior capsular tears were seen in two eyes, of which only one needed a localized vitrectomy. Posterior chamber intraocular lens implantation was possible without any complication in all the cases. Postoperative uveitis seen in three cases was easily controlled with periocular steroids. Best corrected visual acuity at last examination was 6/9 or better in 7 cases and 6/12 in one case with posterior capsular opacification. Conclusions: Timing and necessity of ILFB removal may be adjusted according to the foreign body characteristics and associated ocular trauma, choosing, as far as possible, the least traumatic procedure. Use of forceps rather than magnets is safer for the removal of the ILFB. Co-existent posterior capsular tears need to be anticipated and dealt with when encountered.

  15. Sensory-parietal cortical stimulation improves motor recovery in severe capsular infarct.

    Science.gov (United States)

    Kim, Ra Gyung; Cho, Jongwook; Ree, Jinkyue; Kim, Hyung-Sun; Rosa-Neto, Pedro; Kim, Jin-Myung; Lee, Min-Cheol; Kim, Hyoung-Ihl

    2016-12-01

    The prevalence of subcortical white matter strokes in elderly patients is on the rise, but these patients show mixed responses to conventional rehabilitative interventions. To examine whether cortical electrical stimulation can promote motor recovery after white matter stroke, we delivered stimulation to a small or wide region of sensory-parietal cortex for two weeks in a rodent model of circumscribed subcortical capsular infarct. The sham-operated group (SOG) showed persistent and severe motor impairments together with decreased activation in bilateral sensorimotor cortices and striatum. In contrast, sensory-parietal cortex stimulation significantly improved motor recovery: final recovery levels were 72.9% of prelesion levels in the wide stimulation group (WSG) and 37% of prelesion levels in the small stimulation group (SSG). The microPET imaging showed reversal of cortical diaschisis in both groups: in both hemispheres for the WSG, and in the hemisphere ipsilateral to stimulation in the SSG. In addition, we observed activation of the corpus callosum and subcortical corticostriatal structures after stimulation. The results from the c-Fos mapping study were grossly consistent with the microPET imaging. Sensory-parietal cortex stimulation may therefore be a useful strategy for overcoming the limits of rehabilitative training in patients with severe forms of subcortical capsular infarct. © The Author(s) 2015.

  16. A Comparison of Keyword Subject Searching on Six British University OPACs Online Public Access Catalogs.

    Science.gov (United States)

    Aanonson, John

    1987-01-01

    Compares features of online public access catalogs (OPACs) at six British universities: (1) Cambridge; (2) Hull; (3) Newcastle; (4) Surrey; (5) Sussex; and (6) York. Results of keyword subject searches on two topics performed on each of the OPACs are reported and compared. Six references are listed. (MES)

  17. The Searching Behavior of Remote Users: A Study of One Online Public Access Catalog (OPAC).

    Science.gov (United States)

    Kalin, Sally W.

    1991-01-01

    Describes a study that was conducted to determine whether the searching behavior of remote users of LIAS (Library Information Access System), Pennsylvania State University's online public access catalog (OPAC), differed from those using the OPAC within the library. Differences in search strategies and in user satisfaction are discussed. (eight…

  18. Opacity measurements of tamped NaBr samples heated by z-pinch X-rays

    International Nuclear Information System (INIS)

    Bailey, J.E.; Arnault, P.; Blenski, T.; Dejonghe, G.; Peyrusse, O.; MacFarlane, J.J.; Mancini, R.C.; Cuneo, M.E.; Nielsen, D.S.; Rochau, G.A.

    2003-01-01

    Laboratory measurements provide benchmark data for wavelength-dependent plasma opacities to assist inertial confinement fusion, astrophysics, and atomic physics research. There are several potential benefits to using z-pinch radiation for opacity measurements, including relatively large cm-scale lateral sample sizes and relatively-long 3-5 ns experiment durations. These features enhance sample uniformity. The spectrally resolved transmission through a CH-tamped NaBr foil was measured. The z-pinch produced the X-rays for both the heating source and backlight source. The (50±4) eV foil electron temperature and (3±1)x10 21 cm -3 foil electron density were determined by analysis of the Na absorption features. LTE and NLTE opacity model calculations of the n=2 to 3, 4 transitions in bromine ionized into the M-shell are in reasonably good agreement with the data

  19. Opacity Limit for Supermassive Protostars

    Science.gov (United States)

    Becerra, Fernando; Marinacci, Federico; Inayoshi, Kohei; Bromm, Volker; Hernquist, Lars E.

    2018-04-01

    We present a model for the evolution of supermassive protostars from their formation at {M}\\star ≃ 0.1 {M}ȯ until their growth to {M}\\star ≃ {10}5 {M}ȯ . To calculate the initial properties of the object in the optically thick regime, we follow two approaches: one based on idealized thermodynamic considerations, and another based on a more detailed one-zone model. Both methods derive a similar value of {n}{{F}}≃ 2× {10}17 {cm}}-3 for the density of the object when opacity becomes important, i.e., the opacity limit. The subsequent evolution of the growing protostar is determined by the accretion of gas onto the object and can be described by a mass–radius relation of the form {R}\\star \\propto {M}\\star 1/3 during the early stages, and of the form {R}\\star \\propto {M}\\star 1/2 when internal luminosity becomes important. For the case of a supermassive protostar, this implies that the radius of the star grows from {R}\\star ≃ 0.65 {au} to {R}\\star ≃ 250 {au} during its evolution. Finally, we use this model to construct a subgrid recipe for accreting sink particles in numerical simulations. A prime ingredient thereof is a physically motivated prescription for the accretion radius and the effective temperature of the growing protostar embedded inside it. From the latter, we can conclude that photoionization feedback can be neglected until very late in the assembly process of the supermassive object.

  20. Evaluation of Artisan aphakic intraocular lens in cases of pediatric aphakia with insufficient capsular support.

    Science.gov (United States)

    Gawdat, Ghada I; Taher, Sameh G; Salama, Marwa M; Ali, Adel A

    2015-06-01

    To evaluate the visual outcomes and complications after Artisan iris-claw lens implantation in aphakic children with insufficient capsular support. In this prospective, interventional noncontrolled study, aphakic eyes of consecutive patients >2 years of age with insufficient capsular support who underwent Artisan intraocular lens (IOL) implantation between June 2011 and December 2012 were followed for 1 year. Patients with anterior chamber depth IOL were included, 18 eyes with subluxated lens and 7 following trauma. The mean preoperative logMAR best-corrected visual acuity for traumatic aphakic patients was 0.95 ± 0.36; for patients with subluxation, 0.7 ± 0.26. Values improved at 1 year to 0.38 ± 0.15 (P IOL implantation for pediatric aphakia achieved a good visual outcome. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  1. A case of decentered IOL managed with optic buttonholing.

    Science.gov (United States)

    Gupta, Shikha; Khokhar, Sudarshan; Agarwal, Tushar

    2014-12-01

    We describe an unusual case which presented with late lateral IOL decentration secondary to bag subluxation in the presence of a posterior capsular defect. Instead of approaching the case with the usual IOL exchange with iris-fixated or anterior chamber IOL or by fixating it to the sclera, a relatively non-invasive sutureless method of IOL re-centration was performed by buttonholing the optic into the posterior capsular defect. It enabled a perfect IOL centration with minimal incidence of astigmatism, inflammation, macular edema, secondary glaucoma, or corneal decompensation.

  2. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  3. Different accumulation profiles of multiple components between pericarp and seed of Alpinia oxyphylla capsular fruit as determined by UFLC-MS/MS.

    Science.gov (United States)

    Chen, Feng; Li, Hai-Long; Tan, Yin-Feng; Guan, Wei-Wei; Zhang, Jun-Qing; Li, Yong-Hui; Zhao, Yuan-Sheng; Qin, Zhen-Miao

    2014-04-10

    Plant secondary metabolites are known to not only play a key role in the adaptation of plants to their environment, but also represent an important source of active pharmaceuticals. Alpinia oxyphylla capsular fruits, made up of seeds and pericarps, are commonly used in traditional East Asian medicines. In clinical utilization of these capsular fruits, inconsistent processing approaches (i.e., hulling pericarps or not) are employed, with the potential of leading to differential pharmacological effects. Therefore, an important question arises whether the content levels of pharmacologically active chemicals between the seeds and pericarps of A. oxyphylla are comparable. Nine secondary metabolites present in A. oxyphylla capsular fruits, including flavonoids (e.g., tectochrysin, izalpinin, chrysin, apigenin-4',7-dimethylether and kaempferide), diarylheptanoids (e.g., yakuchinone A and B and oxyphyllacinol) and sesquiterpenes (e.g., nootkatone), were regarded as representative constituents with putative pharmacological activities. This work aimed to investigate the abundance of the nine constituents in the seeds and pericarps of A. oxyphylla. Thirteen batches of A. oxyphylla capsular fruits were gathered from different production regions. Accordingly, an ultra-fast high performance liquid chromatography/quadrupole tandem mass spectrometry (UFLC-MS/MS) method was developed and validated. We found that: (1) the nine secondary metabolites were differentially concentrated in seeds and fruit capsules; (2) nootkatone is predominantly distributed in the seeds; in contrast, the flavonoids and diarylheptanoids are mainly deposited in the capsules; and (3) the content levels of the nine secondary metabolites occurring in the capsules varied greatly among different production regions, although the nootkatone levels in the seeds were comparable among production regions. These results are helpful to evaluating and elucidating pharmacological activities of A. oxyphylla capsular

  4. Different Accumulation Profiles of Multiple Components Between Pericarp and Seed of Alpinia oxyphylla Capsular Fruit as Determined by UFLC-MS/MS

    Directory of Open Access Journals (Sweden)

    Feng Chen

    2014-04-01

    Full Text Available Plant secondary metabolites are known to not only play a key role in the adaptation of plants to their environment, but also represent an important source of active pharmaceuticals. Alpinia oxyphylla capsular fruits, made up of seeds and pericarps, are commonly used in traditional East Asian medicines. In clinical utilization of these capsular fruits, inconsistent processing approaches (i.e., hulling pericarps or not are employed, with the potential of leading to differential pharmacological effects. Therefore, an important question arises whether the content levels of pharmacologically active chemicals between the seeds and pericarps of A. oxyphylla are comparable. Nine secondary metabolites present in A. oxyphylla capsular fruits, including flavonoids (e.g., tectochrysin, izalpinin, chrysin, apigenin-4',7-dimethylether and kaempferide, diarylheptanoids (e.g., yakuchinone A and B and oxyphyllacinol and sesquiterpenes (e.g., nootkatone, were regarded as representative constituents with putative pharmacological activities. This work aimed to investigate the abundance of the nine constituents in the seeds and pericarps of A. oxyphylla. Thirteen batches of A. oxyphylla capsular fruits were gathered from different production regions. Accordingly, an ultra-fast high performance liquid chromatography/quadrupole tandem mass spectrometry (UFLC-MS/MS method was developed and validated. We found that: (1 the nine secondary metabolites were differentially concentrated in seeds and fruit capsules; (2 nootkatone is predominantly distributed in the seeds; in contrast, the flavonoids and diarylheptanoids are mainly deposited in the capsules; and (3 the content levels of the nine secondary metabolites occurring in the capsules varied greatly among different production regions, although the nootkatone levels in the seeds were comparable among production regions. These results are helpful to evaluating and elucidating pharmacological activities of A. oxyphylla

  5. Ground-glass opacity at high resolution CT: an approach for differential diagnosis

    International Nuclear Information System (INIS)

    Spina, Juan C.; Rogondino, Jose; Vidales, Valeria; Rolnik, Maria C.; Montanari, Mariano; Salazar, Santiago N.

    2004-01-01

    Purpose: To evaluate the Ground-Glass Opacity in high resolution computed tomography (HRCT) with its underlying abnormality and anatomic distribution and its correlation with different etiologies. Methods: A 38 patients series, (32 men, 16 women, mean age 54,6 years, range 20-28) was retrospectively analyzed. They were evaluated with high resolution computed tomography, 2 mm thick sections and 10 mm of interval. Contrast intravenous iodinated contrast (no-ionic) was injected in 11 patients. The final diagnosis was made with sputum analysis, bronchioalveolar lavage, trans bronchial biopsy and open lung biopsy. Results: The differential diagnosis of ground glass opacity is based on analyzing their anatomic resolution and the underlying pathology in the lung parenchyma. Centrilobular distribution indicated early air-spaces pathology produced in our series by 21 infections, 4 pulmonary hemorrhages, 1 hypersensitivity pneumonitis and 1 descamative interstitial pneumonitis. Panlobular distribution, alveolar proteinosis (1 case) sarcoidosis (1 case) drug toxicity 1 case and one case of pneumocystis carinii. Peripherical distribution typical of early idiopathic fibrosis (1). Bronchiolitis obliterans with organizing pneumonia (1). Structural alterations of the lung parenchyma with bronchiectasias was seen in 16 cases, cystic lesions in 3 cases, sub pleural linear opacities 4 cases, peribronchovascular interstitial thickening or nodularity and emphysema in 10 cases. Conclusion: HRCT is useful to evaluate ground glass opacities pattern with the anatomic distribution and the underlying structural pathology. These findings under some clinical circumstances can suggest a specific diagnosis in most cases, indicating a potentially treatable disease. (author)

  6. New techniques for evaluating the gastrointestinal tract: capsular endoscopy

    Directory of Open Access Journals (Sweden)

    A E Karateyev

    2009-01-01

    Full Text Available The paper describes a procedure for capsular endoscopy (CE, a new high-technology method of evaluating the small bowel, and reports on its use in rheumatological care. Small bowel involvement is noted to be frequently encountered in rheumatic diseases, such as Behcet's disease, diffuse scleroderma, and seronegative spondylitis. According to the data of clinical trials, CE is effective in timely detecting this visceral abnormality. At the same time, CE is actually the only accurate method of diagnosing drug-induced enteropathy, a potentially menacing disease that frequently occurs with the use of nonsteroidal anti-inflammatory drugs.

  7. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    Directory of Open Access Journals (Sweden)

    Liang-Nan Sun

    2017-07-01

    Full Text Available AIM: To evaluate the clinical results of capsular tension ring(CTRimplantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyeswith congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOLimplantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperatively and postoperatively. RESULTS: Uncorrected vision of all eyes increased after surgery, and all cases had different degree of IOL decentration after surgery. Two eyes received CTR scleral fixation 3mo after surgery because the IOL decentration aggravated during the follow-up period. CONCLUSION: Phacoemulsification with CTR and IOL implantation is effective and safe for congenital lens subluxation. The implantation of CTR increase the stability of the capsular bag, improve the safety of surgery, and maintain the right position of IOL. CTR scleral fixation is a effective supplement for progressive cases.

  8. Opacity annotation of diffuse lung diseases using deep convolutional neural network with multi-channel information

    Science.gov (United States)

    Mabu, Shingo; Kido, Shoji; Hashimoto, Noriaki; Hirano, Yasushi; Kuremoto, Takashi

    2018-02-01

    This research proposes a multi-channel deep convolutional neural network (DCNN) for computer-aided diagnosis (CAD) that classifies normal and abnormal opacities of diffuse lung diseases in Computed Tomography (CT) images. Because CT images are gray scale, DCNN usually uses one channel for inputting image data. On the other hand, this research uses multi-channel DCNN where each channel corresponds to the original raw image or the images transformed by some preprocessing techniques. In fact, the information obtained only from raw images is limited and some conventional research suggested that preprocessing of images contributes to improving the classification accuracy. Thus, the combination of the original and preprocessed images is expected to show higher accuracy. The proposed method realizes region of interest (ROI)-based opacity annotation. We used lung CT images taken in Yamaguchi University Hospital, Japan, and they are divided into 32 × 32 ROI images. The ROIs contain six kinds of opacities: consolidation, ground-glass opacity (GGO), emphysema, honeycombing, nodular, and normal. The aim of the proposed method is to classify each ROI into one of the six opacities (classes). The DCNN structure is based on VGG network that secured the first and second places in ImageNet ILSVRC-2014. From the experimental results, the classification accuracy of the proposed method was better than the conventional method with single channel, and there was a significant difference between them.

  9. NASA study of cataract in astronauts (NASCA). Report 1: Cross-sectional study of the relationship of exposure to space radiation and risk of lens opacity.

    Science.gov (United States)

    Chylack, Leo T; Peterson, Leif E; Feiveson, Alan H; Wear, Mary L; Manuel, F Keith; Tung, William H; Hardy, Dale S; Marak, Lisa J; Cucinotta, Francis A

    2009-07-01

    The NASA Study of Cataract in Astronauts (NASCA) is a 5-year longitudinal study of the effect of space radiation exposure on the severity/progression of nuclear, cortical and posterior subcapsular (PSC) lens opacities. Here we report on baseline data that will be used over the course of the longitudinal study. Participants include 171 consenting astronauts who flew at least one mission in space and a comparison group made up of three components: (a) 53 astronauts who had not flown in space, (b) 95 military aircrew personnel, and (c) 99 non-aircrew ground-based comparison subjects. Continuous measures of nuclear, cortical and PSC lens opacities were derived from Nidek EAS 1000 digitized images. Age, demographics, general health, nutritional intake and solar ocular exposure were measured at baseline. Astronauts who flew at least one mission were matched to comparison subjects using propensity scores based on demographic characteristics and medical history stratified by gender and smoking (ever/never). The cross-sectional data for matched subjects were analyzed by fitting customized non-normal regression models to examine the effect of space radiation on each measure of opacity. The variability and median of cortical cataracts were significantly higher for exposed astronauts than for nonexposed astronauts and comparison subjects with similar ages (P=0.015). Galactic cosmic space radiation (GCR) may be linked to increased PSC area (P=0.056) and the number of PSC centers (P=0.095). Within the astronaut group, PSC size was greater in subjects with higher space radiation doses (P=0.016). No association was found between space radiation and nuclear cataracts. Cross-sectional data analysis revealed a small deleterious effect of space radiation for cortical cataracts and possibly for PSC cataracts. These results suggest increased cataract risks at smaller radiation doses than have been reported previously.

  10. Library OPACs on the Web: Finding and Describing Directories.

    Science.gov (United States)

    Henry, Marcia

    1997-01-01

    Provides current descriptions of some of the major directories that link to library catalogs on the World Wide Web. Highlights include LibWeb; Hytelnet; WebCats; WWW Library Directory; and techniques for finding new library OPAC (online public access catalog) directories. (LRW)

  11. Eficacia de la vacuna meningocócica de polisacárido capsular del grupo C

    Directory of Open Access Journals (Sweden)

    González Enríquez Jesús

    1997-01-01

    Full Text Available FUNDAMENTO: Este trabajo consiste esencialmente en una revisión sistemática de la literatura científica sobre los efectos, intensidad y duración de la respuesta serológica, así como sobre la eficacia, efectividad y seguridad de la vacuna meningocócica de polisacárido capsular del grupo C. MÉTODOS: Búsqueda en repertorio MEDLINE en el periodo 1970-1996. Búsqueda específica de ensayos clínicos aleatorizados y estudios de intervención prospectivos en humanos con vacunas de polisacáridos capsulares de meningococo en el mismo repertorio y periodo. Análisis crítico de literatura científica y síntesis de evidencia. RESULTADOS: La vacuna de polisacárido capsular del serogrupo C es considerada segura y ha mostrado una eficacia superior al 85% en adultos y niños mayores, 70% (IC95%: 5-91% en niños menores de 5 años y 55% (IC90%: 14-76% en niños de 2-3 años. La vacuna no se ha mostrado eficaz en niños menores de 2 años. La duración de niveles de anticuerpos protectores disminuye con la edad. La proporción de niños menores de 6 años efectivamente protegidos al año de la vacunación es baja. La vacunación no limita la respuesta serológica de vacunaciones ulteriores. CONCLUSIONES: La vacuna meningocócica de polisacárido capsular del serogrupo C está indicada en adultos y niños mayores de 2 años como protección contra la enfermedad meningocócica causada por este serogrupo en situaciones de alto riesgo de enfermedad. La escasa protección que ofrece la vacuna en los menores de 2 años, la limitada eficacia en menores de 5 años y la corta duración de la inmunidad que confiere a estas edades, hace que la vacunación rutinaria no esté recomendada y que la vacuna se use fundamentalmente en el control de brotes epidémicos causados por serogrupo C.

  12. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  13. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    International Nuclear Information System (INIS)

    Avgoustidis, Anastasios; Redondo, Javier; Verde, Licia; Jimenez, Raul

    2010-04-01

    We update constraints on cosmic opacity by combining recent SN Type Ia data compilation with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter ε parametrising deviations from the luminosity-angular diameter distance relation (d L =d A (1+z) 2+ε ), is ε=-0.04 -0.07 +0.08 (2-σ). For the redshift range between 0.2 and 0.35 this corresponds to an opacity Δτ<0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and minicharged particles. (orig.)

  14. Calculation of radiative opacity of plasma mixtures using a relativistic screened hydrogenic model

    International Nuclear Information System (INIS)

    Mendoza, M.A.; Rubiano, J.G.; Gil, J.M.; Rodríguez, R.; Florido, R.; Espinosa, G.; Martel, P.; Mínguez, E.

    2014-01-01

    We present the code ATMED based on an average atom model and conceived for fast computing the population distribution and radiative properties of hot and dense single and multicomponent plasmas under LTE conditions. A relativistic screened hydrogenic model (RSHM), built on a new set of universal constants considering j-splitting, is used to calculate the required atomic data. The opacity model includes radiative bound–bound, bound–free, free–free, and scattering processes. Bound–bound line-shape function has contributions from natural, Doppler and electron-impact broadenings. An additional dielectronic broadening to account for fluctuations in the average level populations has been included, which improves substantially the Rosseland mean opacity results. To illustrate the main features of the code and its capabilities, calculations of several fundamental quantities of one-component plasmas and mixtures are presented, and a comparison with previously published data is performed. Results are satisfactorily compared with those predicted by more elaborate codes. - Highlights: • A new opacity code, ATMED, based on the average atom approximation is presented. • Atomic data are computed by means of a relativistic screened hydrogenic model. • An effective bound level degeneracy is included for accounting pressure ionization. • A new dielectronic line broadening is included to improve the mean opacities. • ATMED has the possibility to handle with single element and multicomponent plasmas

  15. Stenosing Tenosynovitis of the Flexor Hallucis Longus Tendon Associated with the Plantar Capsular Accessory Ossicle at the Interphalangeal Joint of the Great Toe

    Directory of Open Access Journals (Sweden)

    Song Ho Chang

    2017-01-01

    Full Text Available This report presents a case of stenosing tenosynovitis of the flexor hallucis longus tendon associated with the plantar capsular accessory ossicle at the interphalangeal joint of the great toe, which was confirmed by intraoperative observation and was successfully treated with surgical resection of the ossicle. As the plantar capsular accessory ossicle was not visible radiographically due to the lack of ossification, ultrasonography was helpful for diagnosing this disorder.

  16. Opacplot2: Enabling tabulated EoS and opacity compatibility for HEDLP simulations with the FLASH code

    Science.gov (United States)

    Laune, Jordan; Tzeferacos, Petros; Feister, Scott; Fatenejad, Milad; Yurchak, Roman; Flocke, Norbert; Weide, Klaus; Lamb, Donald

    2017-10-01

    Thermodynamic and opacity properties of materials are necessary to accurately simulate laser-driven laboratory experiments. Such data are compiled in tabular format since the thermodynamic range that needs to be covered cannot be described with one single theoretical model. Moreover, tabulated data can be made available prior to runtime, reducing both compute cost and code complexity. This approach is employed by the FLASH code. Equation of state (EoS) and opacity data comes in various formats, matrix-layouts, and file-structures. We discuss recent developments on opacplot2, an open-source Python module that manipulates tabulated EoS and opacity data. We present software that builds upon opacplot2 and enables easy-to-use conversion of different table formats into the IONMIX format, the native tabular input used by FLASH. Our work enables FLASH users to take advantage of a wider range of accurate EoS and opacity tables in simulating HELP experiments at the National Laser User Facilities.

  17. Vaccines for the prevention of meningococcal capsular group B disease: What have we recently learned?

    Science.gov (United States)

    Findlow, Jamie

    2016-01-01

    Meningococcal disease remains a feared and devastating cause of sepsis and meningitis. Disease incidence is highest among infants and children although a significant burden of disease is experienced by adolescents, young adults and those with specific risk-factors. Prevention of disease against capsular groups A, C, W and Y; 4 of the 5 most pathogenic groups is achievable using capsular polysaccharide vaccines. It has only recently been possible to provide protection against capsular group B (MenB) strains following the licensure of a 4 component group B vaccine (4CMenB) in Europe in 2013. Following licensure, 4CMenB has been used in specific at-risk groups and in response to outbreaks of MenB disease. The largest outbreak interventions have been in students at 2 universities in the United States and for all individuals aged 2 months to 20 years of age in Quebec, Canada. The vaccine was recommended in February 2014 for implementation into the UK infant schedule at 2, 4 and 12 months of age, although it has taken over 12 months to resolve procurement discussions to enable implementation. The UK recommendation incorporates prophylactic paracetamol with infant doses when 4CMenB is administered concomitantly with routine vaccines. This is based on recent data demonstrating the ability of paracetamol to reduce fever rates to background levels without impacting immunogenicity. Post-implementation surveillance will be important to provide vaccine efficacy data as this was not possible to determine in pre-licensure studies due to the relative infrequency of MenB cases.

  18. Análise da camada de fibras nervosas pelo GDx em pacientes pseudofácicos com opacidades da cápsula posterior Analysis of the nerve fiber layer using GDx in pseudophakic patients with posterior capsular opacification

    Directory of Open Access Journals (Sweden)

    Tatiana Azevedo Arraes

    2008-02-01

    Full Text Available OBJETIVO: Avaliar se a opacificação de cápsula posterior (OCP influenciaria na análise da camada de fibras nervosas pela polarimetria "scanning laser" (GDx. MÉTODOS: Trinta e sete pacientes pseudofácicos não glaucomatosos foram submetidos a análise da camada de fibras nervosas pelo GDx antes e após a realização de capsulotomia com Nd:YAG laser. RESULTADOS: Em cinco olhos, o GDx não conseguiu imagens aceitáveis pelos parâmetros de aquisição do aparelho. Em todos os outros, não foi observada diferença significante entre os valores médios das variáveis antes e após a realização da capsulotomia posterior. CONCLUSÃO: A presença de OCP em graus moderados e/ou quando há imagens aceitáveis em pacientes pseudofácicos não influencia o resultado da análise das imagens das fibras do nervo óptico pelo GDx. Apenas intensos graus de OCP que impeçam a obtenção de imagem analisável pelo aparelho inviabilizam o exame.PURPOSE: To evaluate if posterior capsule opacification (PCO would alter the analysis of nerve fiber layer using the scanning laser polarimetry (GDx. METHODS: Pseudophakic non-glaucomatosous eyes (37 patients underwent nerve fiber layer analysis using GDx before and after posterior capsulotomy with Nd:YAG Laser. RESULTS: In five eyes, GDx did not obtain acceptable images using the device's parameters of acquisition. In the others, mean variable values did not reach significant difference before and after posterior capsulotomy. CONCLUSION: Moderate degrees of PCO and/or acceptable images in pseudophakic patients do not alter the analysis of nerve fiber layer by GDx. Only intense degrees of PCO that hinder analyzable images make the examination impracticable.

  19. Night and Day: The Opacity of Clouds Measured by the Mars Orbiter Laser Altimeter (MOLA)

    Science.gov (United States)

    Neumann, G. A.; Wilson, R. J.

    2006-01-01

    The Mars Orbiter Laser Altimeter (MOLA) [l] on the Mars Global Surveyor spacecraft ranged to clouds over the course of nearly two Mars years [2] using an active laser ranging system. While ranging to the surface, the instrument was also able to measure the product of the surface reflectivity with the two-way atmospheric transmission at 1064 nm. Furthermore, the reflectivity has now been mapped over seasonal cycles using the passive radiometric capability built into MOLA [3]. Combining these measurements, the column opacity may be inferred. MOLA uniquely provides these measurements both night and day. This study examines the pronounced nighttime opacity of the aphelion season tropical water ice clouds, and the indiscernibly low opacity of the southern polar winter clouds. The water ice clouds (Figure 1) do not themselves trigger the altimeter but have measured opacities tau > 1.5 and are temporally and spatially correlated with temperature anomalies predicted by a Mars Global Circulation Model (MGCM) that incorporates cloud radiative effects [4]. The south polar CO2 ice clouds trigger the altimeter with a very high backscatter cross-section over a thickness of 3-9 m and are vertically dispersed over several km, but their total column opacities lie well below the MOLA measurement limit of tau = 0.7. These clouds correspond to regions of supercooled atmosphere that may form either very large specularly reflecting particles [2] or very compact, dense concentrations (>5x10(exp 6)/cu m) of 100-p particles

  20. Open-Source Tools for Enhancing Full-Text Searching of OPACs: Use of Koha, Greenstone and Fedora

    Science.gov (United States)

    Anuradha, K. T.; Sivakaminathan, R.; Kumar, P. Arun

    2011-01-01

    Purpose: There are many library automation packages available as open-source software, comprising two modules: staff-client module and online public access catalogue (OPAC). Although the OPAC of these library automation packages provides advanced features of searching and retrieval of bibliographic records, none of them facilitate full-text…

  1. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, Anastasios [Centre for Theoretical Cosmology, DAMTP, CMS, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Burrage, Clare [Deutsches Elektronen Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Redondo, Javier [Max Planck Institut für Physik, Föhringer Ring 6, D-80805, Munich (Germany); Verde, Licia; Jimenez, Raul, E-mail: a.avgoustidis@damtp.cam.ac.uk, E-mail: clare.burrage@desy.de, E-mail: redondo@mppmu.mpg.de, E-mail: liciaverde@icc.ub.edu, E-mail: raul.jimenez@icc.ub.edu [ICREA and Institute for Sciences of the Cosmos (ICC), University of Barcelona, IEEC, Barcelona 08028 (Spain)

    2010-10-01

    We update constraints on cosmic opacity by combining recent SN Type Ia data with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter ε parametrising deviations from the luminosity-angular diameter distance relation (d{sub L} = d{sub A}(1+z){sup 2+ε}), is ε = −0.04{sub −0.07}{sup +0.08} (2-σ). For the redshift range between 0.2 and 0.35 this corresponds to an opacity Δτ < 0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and mini-charged particles.

  2. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, Anastasios [DAMTP, CMS, Cambridge (United Kingdom). Centre for Theoretical Cosmology; Burrage, Clare [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Redondo, Javier [Max-Planck-Institut fuer Physik, Munich (Germany); Verde, Licia; Jimenez, Raul [Barcelona Univ., IEEC (ES). ICREA and Inst. for Sciences of the Cosmos (ICC)

    2010-04-15

    We update constraints on cosmic opacity by combining recent SN Type Ia data compilation with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter {epsilon} parametrising deviations from the luminosity-angular diameter distance relation (d{sub L}=d{sub A}(1+z){sup 2+{epsilon}}), is {epsilon}=-0.04{sub -0.07}{sup +0.08} (2-{sigma}). For the redshift range between 0.2 and 0.35 this corresponds to an opacity {delta}{tau}<0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and minicharged particles. (orig.)

  3. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  4. Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system.

    Science.gov (United States)

    Vilaseca, Meritxell; Romero, Maria José; Arjona, Montserrat; Luque, Sergio Oscar; Ondategui, Juan Carlos; Salvador, Antoni; Güell, José L; Artal, Pablo; Pujol, Jaume

    2012-09-01

    To evaluate objectively intraocular scattering in eyes with nuclear, cortical and posterior subcapsular cataracts by means of an objective scatter index (OSI) obtained from double-pass images. To compare the results with those obtained using clinical conventional procedures. In this prospective, observational, cross-sectional, non-consecutive case series study, 188 eyes with cataracts of 136 patients were analysed (123 eyes had nuclear, 41 eyes had cortical and 24 eyes had posterior subcapsular cataracts). The control group consisted of 117 eyes of 68 healthy patients. Patient examination included subjective refraction, best spectacle-corrected visual acuity (BSCVA), cataract grade using the lens opacities classification system III (LOCS III) and OSI. We found a decrease in the BSCVA and an increase in the OSI with increasing cataract grade. Statistically significant differences were observed when the OSI of eyes without cataracts and those with different LOCS III were compared. The comparison between the OSI and LOCS III reported good percentages of agreement regarding the number of eyes classified in equivalent levels: 72.4% (nuclear cataracts), 86.6% (cortical cataracts) and 84.3% (posterior subcapsular cataracts). A non-linear regression model was applied between OSI and BSCVA, which resulted in the following multiple correlation coefficients: r=0.878 (nuclear), r=0.843 (cortical) and r=0.844 (posterior subcapsular). The results of the study showed that OSI is a useful parameter for evaluating large amounts of intraocular scattering that can be used, in combination with other conventional procedures, as a valuable tool in clinical practice to grade cataracts objectively.

  5. Hohlraum modeling for opacity experiments on the National Ignition Facility

    Science.gov (United States)

    Dodd, E. S.; DeVolder, B. G.; Martin, M. E.; Krasheninnikova, N. S.; Tregillis, I. L.; Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Moore, A. S.; Kline, J. L.; Johns, H. M.; Liedahl, D. A.; Cardenas, T.; Olson, R. E.; Wilde, B. H.; Urbatsch, T. J.

    2018-06-01

    This paper discusses the modeling of experiments that measure iron opacity in local thermodynamic equilibrium (LTE) using laser-driven hohlraums at the National Ignition Facility (NIF). A previous set of experiments fielded at Sandia's Z facility [Bailey et al., Nature 517, 56 (2015)] have shown up to factors of two discrepancies between the theory and experiment, casting doubt on the validity of the opacity models. The purpose of the new experiments is to make corroborating measurements at the same densities and temperatures, with the initial measurements made at a temperature of 160 eV and an electron density of 0.7 × 1022 cm-3. The X-ray hot spots of a laser-driven hohlraum are not in LTE, and the iron must be shielded from a direct line-of-sight to obtain the data [Perry et al., Phys. Rev. B 54, 5617 (1996)]. This shielding is provided either with the internal structure (e.g., baffles) or external wall shapes that divide the hohlraum into a laser-heated portion and an LTE portion. In contrast, most inertial confinement fusion hohlraums are simple cylinders lacking complex gold walls, and the design codes are not typically applied to targets like those for the opacity experiments. We will discuss the initial basis for the modeling using LASNEX, and the subsequent modeling of five different hohlraum geometries that have been fielded on the NIF to date. This includes a comparison of calculated and measured radiation temperatures.

  6. Lightweight, high-opacity Bible paper by fiber loading

    Science.gov (United States)

    Klaus Doelle; Oliver Heise; John H. Klungness; Said M. AbuBakr

    2000-01-01

    This paper has been prepared in order to discuss Fiber Loading™ for lightweight, high-opacity bible paper. Incorporating fillers within pulp fibers has been subject to research since 1960 (Green et al. 1962, Scallan et al. 1985, Allen et al. 1992). Fiber Loading™ is a method for manufacturing precipitated calcium carbonate (PCC) directly within the pulp processing...

  7. Posterior glenoid rim deficiency in recurrent (atraumatic) posterior shoulder instability

    International Nuclear Information System (INIS)

    Weishaupt, D.; Zanetti, M.; Hodler, J.; Nyffeler, R.W.; Gerber, C.

    2000-01-01

    Objective. To assess the shape of the posterior glenoid rim in patients with recurrent (atraumatic) posterior instability.Design and patients. CT examinations of 15 shoulders with recurrent (atraumatic) posterior instability were reviewed in masked fashion with regard to abnormalities of the glenoid shape, specifically of its posterior rim. The glenoid version was also assessed. The findings were compared with the findings in 15 shoulders with recurrent anterior shoulder instability and 15 shoulders without instability. For all patients, surgical correlation was available.Results. Fourteen of the 15 (93%) shoulders with recurrent (atraumatic) posterior shoulder instability had a deficiency of the posteroinferior glenoid rim. In patients with recurrent anterior instability or stable shoulders such deficiencies were less common (60% and 73%, respectively). The craniocaudal length of the deficiencies was largest in patients with posterior instability. When a posteroinferior deficiency with a craniocaudal length of 12 mm or more was defined as abnormal, sensitivity and specificity for diagnosing recurrent (atraumatic) posterior instability were 86.7% and 83.3%, respectively. There was a statistically significant difference in glenoid version between shoulders with posterior instability and stable shoulders (P=0.01).Conclusion. Recurrent (atraumatic) posterior shoulder instability should be considered in patients with a bony deficiency of the posteroinferior glenoid rim with a craniocaudal length of more than 12 mm. (orig.)

  8. An investigation of the opacity of high-Z mixture and implications for inertial confinement fusion hohlraum design

    International Nuclear Information System (INIS)

    Wang, P.; MacFarlane, J.J.; Orzechowski, T.J.

    1997-01-01

    We use an unresolved transition array model to investigate the opacities of high-Z materials and their mixtures which are of interest to indirect-drive inertial confinement fusion hohlraum design. In particular, we report on calculated opacities for pure Au, Gd, and Sm, as well as Au endash Sm and Au endash Gd mixtures. Our results indicate that mixtures of Au endash Gd and Au endash Sm can produce a significant enhancement in the Rosseland mean opacity. Radiation hydrodynamics simulations of Au radiation burnthrough are also presented, and compared with NOVA experimental data. copyright 1997 American Institute of Physics

  9. Non-LTE H2+ as the source of missing opacity in the solar atmosphere

    Science.gov (United States)

    Swamy, K. S. K.; Stecher, T. P.

    1974-01-01

    The population of the various vibrational levels of the H2+ molecule has been calculated from the consideration of formation and destruction mechanisms. The resulting population is used in calculating the total absorption due to H2+ and is compared with the other known sources of opacity at several optical depths of the solar atmosphere. It is shown that the absorption due to H2+ can probably account for the missing ultraviolet opacity in the solar atmosphere.

  10. Computational Design of Short Pulse Laser Driven Iron Opacity Measurements at Stellar-Relevant Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Madison E. [Univ. of Florida, Gainesville, FL (United States)

    2017-05-20

    Opacity is a critical parameter in the simulation of radiation transport in systems such as inertial con nement fusion capsules and stars. The resolution of current disagreements between solar models and helioseismological observations would bene t from experimental validation of theoretical opacity models. Overall, short pulse laser heated iron experiments reaching stellar-relevant conditions have been designed with consideration of minimizing tamper emission and optical depth effects while meeting plasma condition and x-ray emission goals.

  11. Smoke opacity in agricultural tractor in function of interior and metropolitano diesel mixture in mamona biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Tabile, Rubens Andre [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia; Lopes, Afonso; Camara, Felipe Thomas da; Grotta, Danilo Cesar Checchio; Furlani, Carlos Eduardo Angeli [Universidade Estadual Paulista (DER/UNESP), Jaboticabal, SP (Brazil). Dept. de Engenharia Rural

    2008-07-01

    The great demand for energy sources by production systems allied to scarcity of fossil fuels has motivated the development and production of biodiesel, which is a fuel produced from renewable sources. Given that, the aim of this study was to compare smoke opacity of an agricultural tractor engine, working with metropolitano and interior diesel mixed to mamona biodiesel, in seven proportions. The tests were conducted in the Departamento de Engenharia Rural of UNESP/Jaboticabal - SP. The results showed that the diesel type did influence opacity of smoke, and metropolitano diesel showed best quality. It was also observed that, as biodiesel proportion increased, smoke opacity decreased until B75, turning to increase to B100. (author)

  12. Femtosecond laser-assisted keratoplasty in a child with corneal opacity:case report

    Directory of Open Access Journals (Sweden)

    E. Yu. Markova

    2014-01-01

    Full Text Available Corneal opacities are the fourth cause of blindness world-wide. Over the past two centuries, various corneal transplantation (i.e., keratoplasty methods have been developed and improved. Nowadays, femtolaserssisted keratoplasty is one of most promising techniques. Femtosecond laser have several advantages that provide additional surgical benefits. Among them, no thermal injury, the ability to cut deeply on a single plane and to perform various corneal profiles should be mentioned. In children, corneal disorders are of special importance while femtosecondassisted keraatoplasty case reports are rare. Here, we describe femtosecond laserssisted penetrating keratoplasty in a girl with a rough central corneal opacity.

  13. Safety and effect of femtosecond laser-assisted cataract surgery combined with Cionni capsular tension ring implantation in the management of traumatic lens subluxation

    Directory of Open Access Journals (Sweden)

    Jia-Hui Chen

    2017-07-01

    Full Text Available AIM:To investigate the safety and effect of femtosecond laser-assisted cataract surgery with Cionni modified capsular tension ring(MCTRimplantation in the management of traumatic lens subluxation.METHODS: Totally 11 patients(11 eyeswith traumatic lens subluxation were divided into three groups according to the severity of lens dislocation, ranging from 90° to 120°(4 eyes, 120° to 180°(5 eyesand 180° to 270°(2 eyes. The contact LenSx femtosecond laser cataract surgery platform was applied to create the capsulotomy, prepare nuclear fragmentation and make corneal wound creation. Anterior vitrectomy was performed in some patients during the surgery. After capsular retractors insertion and phacoemulsification, the MCTR was inserted to the capsular bag and fixed to the sclera. Finally, the IOL was implanted into the capsular bag. Postoperative visual acuity, intra- and post-operative complications, anterior capsular opening, IOL and MCTR position and intraocular pressure(IOPwere assessed.RESULTS:The duration of follow-up was 2mo. All the operations were completed successfully. Five eyes underwent cataract surgery combined with anterior vitrectomy. Four eyes had been inserted with 2-eyelet MCTR and seven eyes with 1-eyelet MCTR. The best corrected visual acuity(BCVAafter operation was better than 0.5 in 4 eyes, between 0.3 and 0.5 in 3 eyes, between 0.1 and 0.3 in 3 eyes, and less than 0.1 in 1 eye. Compared with preoperative BCVA, the difference was statistically significant(PCONCLUSION:Femtosecond laser-assisted cataract surgery can improve the success rate of capsulorhexis, and reduce the difficulty of nuclear fragmentation. Femtosecond laser-assisted cataract surgery combined with MCTR implantation is an ideal surgical method for traumatic lens subluxation.

  14. Measurement of nurses' attitudes and knowledge regarding acute care older patients: Psychometrics of the OPACS-US combined with the KOP-Q.

    Science.gov (United States)

    Dikken, Jeroen; Hoogerduijn, Jita G; Lagerwey, Mary D; Shortridge-Baggett, Lillie; Klaassen, Sharon; Schuurmans, Marieke J

    In clinical practice, identifying positive and negative attitudes toward older patients is very important to improve quality of care provided to them. The Older People in Acute Care Survey - United States (OPACS-US) is an instrument measuring hospital nurses attitudes regarding older patients. However, psychometrics have never been assessed. Furthermore, knowledge being related to attitude and behavior should also be measured complementing the OPACS-US. The purpose of this study was to assess structural validity and reliability of the OPACS-US and assess whether the OPACS-US can be complemented with the Knowledge about Older Patients-Quiz (KOP-Q). A multicenter cross sectional design was conducted. Registered nurses (n = 130, mean age 39,9 years; working experience 14,6 years) working in four general hospitals were included in the study. Nurses completed the OPACS-US section A: practice experiences, B: general opinion and the KOP-Q online. Findings demonstrated that the OPACS-US is a valid and reliable survey instrument that measures practice experiences and general opinion. Furthermore, the OPACS-US can be combined with the KOP-Q adding a knowledge construct, and is ready for use within education and/or quality improvement programs in the USA. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Capsular Sialyltransferase Specificity Mediates Different Phenotypes in Streptococcus suis and Group B Streptococcus

    Directory of Open Access Journals (Sweden)

    David Roy

    2018-04-01

    Full Text Available The capsular polysaccharide (CPS represents a key virulence factor for most encapsulated streptococci. Streptococcus suis and Group B Streptococcus (GBS are both well-encapsulated pathogens of clinical importance in veterinary and/or human medicine and responsible for invasive systemic diseases. S. suis and GBS are the only Gram-positive bacteria which express a sialylated CPS at their surface. An important difference between these two sialylated CPSs is the linkage between the side-chain terminal galactose and sialic acid, being α-2,6 for S. suis but α-2,3 for GBS. It is still unclear how sialic acid may affect CPS production and, consequently, the pathogenesis of the disease caused by these two bacterial pathogens. Here, we investigated the role of sialic acid and the putative effect of sialic acid linkage modification in CPS synthesis using inter-species allelic exchange mutagenesis. To this aim, a new molecular biogenetic approach to express CPS with modified sialic acid linkage was developed. We showed that sialic acid (and its α-2,6 linkage is crucial for S. suis CPS synthesis, whereas for GBS, CPS synthesis may occur in presence of an α-2,6 sialyltransferase or in absence of sialic acid moiety. To evaluate the effect of the CPS composition/structure on sialyltransferase activity, two distinct capsular serotypes within each bacterial species were compared (S. suis serotypes 2 and 14 and GBS serotypes III and V. It was demonstrated that the observed differences in sialyltransferase activity and specificity between S. suis and GBS were serotype unrestricted. This is the first time that a study investigates the interspecies exchange of capsular sialyltransferase genes in Gram-positive bacteria. The obtained mutants represent novel tools that could be used to further investigate the immunomodulatory properties of sialylated CPSs. Finally, in spite of common CPS structural characteristics and similarities in the cps loci, sialic acid exerts

  16. Posterior mediastinal biphasic synovial sarcoma in a 12 year-old boy: A case report and review of literature

    Directory of Open Access Journals (Sweden)

    Pal Madhumay

    2010-01-01

    Full Text Available We report a case of biphasic synovial sarcoma of the mediastinum, a very rare tumor, in a 12-year-old boy with left-sided chest pain of 3 years duration at presentation. Chest X-ray showed left-sided opacity with loss of cardiac silhouette and the mediastinum deviated to the opposite side. Computed tomography (CT of thorax showed left-sided posterior mediastinal mass with left-sided pleural effusion and pleural thickening. CT guided fine needle aspiration cytology (FNAC from the mass reported it as spindle cell variant of adenocarcinoma. Ultrasonography (USG of the whole abdomen revealed no abnormality. The mediastinal tumor was resected by left thoracotomy and histopathological report confirmed it to be a biphasic synovial sarcoma with capsule invasion at places.

  17. Radiative properties of stellar envelopes: Comparison of asteroseismic results to opacity calculations and measurements for iron and nickel

    International Nuclear Information System (INIS)

    Turck-Chieze, S.; Gilles, D.; Le Pennec, M.; Blenski, T.; Thais, F.; Bastiani-Ceccotti, S.; Blancard, C.; Caillaud, T.; Cosse, P.; Faussurier, G.; Gilleron, F.; Pain, J.C.; Reverdin, C.; Silvert, V.; Villette, B.; Busquet, M.; Colgan, J.; Guzik, J.; Kilcrease, D.P.; Magee, N.H.; Delahaye, F.; Zeippen, C.J.; Ducreta, J.E.; Fontes, C.J.; Harris, J.W.; Loisel, G.

    2013-01-01

    The international OPAC consortium consists of astrophysicists, plasma physicists and experimentalists who examine opacity calculations used in stellar physics that appear questionable and perform new calculations and laser experiments to understand the differences and improve the calculations. We report on iron and nickel opacities for envelopes of stars from 2 to 14 M and deliver our first conclusions concerning the reliability of the used calculations by illustrating the importance of the configuration interaction and of the completeness of the calculations for temperatures around 15-27 eV. (authors)

  18. Effects of Zafirlukast on the Capsular Fibrosis of Silicone Breast Implants

    Directory of Open Access Journals (Sweden)

    Emre Hocaoglu

    2014-06-01

    Methods: Forty-eight adult female Sprague-Dawley rats were divided into four groups. Smooth-surfaced, gel-filled prostheses were implanted in 36 rats. Group A: The day of the operation, 12 animals received Zafirlukast treatment for 14 weeks (oral gavage, once a day, 6 days a week, 4 mg/kg/day; Group B: 10 weeks after the operation, 12 animals received Zafirlukast treatment for 4 weeks; Group C: 12 animals were implanted but did not receive treatment; Group D: 12 animals did not have an operation, but for 14 weeks received oral gavage containing water instead of Zafirlukast. At the end of the 14 weeks, the implants with the surrounding capsules were extracted. Blind macroscopic inspectional evaluation of the capsules was performed, and microscopic capsular thickness measurements were made. Results: The mean capsular thickness was 0.033 mm (SD: 0.011 in Group A, and 0.089 mm (SD: 0.023 and 0.125 mm (SD: 0.025 in Groups B and C, respectively. Differences between Groups A and C and between Groups A and B were significant (p0.05. Similarly, Macroscopic Inspectional Fibrosis Scoring showed a significant difference between Groups A and C and a non-significant difference between Groups B and C. Conclusion: Daily prophylactic oral administration of Zafirlukast immediately after implantation significantly diminishes the development of fibrotic capsules around the silicone prostheses. [Arch Clin Exp Surg 2014; 3(3.000: 139-146

  19. Structural studies on some capsular antigens from Escherichia Coli and Klebsiella

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, A N

    1987-12-01

    A review of the structural studies of bacterial capsular polysaccharides (K-antigens) from Escherichia coli (E.coli) and Klebsiella is presented. There is a general trend in the structural elucidation of polysaccharides towards the analysis of higher oligosaccharides. This trend has been facilitated by advances in modern instrumental techniques for the analysis of oligosaccharides, for example, high-performance liquid chromatography, mass spectometry and nuclear magnetic resonance spectroscopy. The structural elucidations of the capsular polysaccharides from E. Coli K37 and K55, and Klebsiella K39 are reported. This elucidation of K-antigens provides an insight into the response of mammalian immune systems to antigenic stimuli. The usefulness of bacteriophage degradation as a technique for the structural elucidation of polysaccharides containing repeating unit structures is emphasized. The bacteriophage degradation of E. coli K55 polysaccharide illustrates that bacteriophage-borne enzymes may be used to degrade chemically related carbohydrate materials. The bacteriophage technique for the structural elucidation of the Klebsiella K39 polysaccharide also illustrates the advantages of this technique where the polysaccharide contains labile glycosidic bonds which are readily cleaved during standard chemical analysis. The enzymatic degradation of polysaccharides allows high yields of specific oligosaccharides to be recovered. The feasibility of analysing small amounts of carbohydrate material has become realistic due to improved instrumental capabilities. At the same time, more detailed information concerning the fine structure of known carbohydrate materials can be elucidated. 421 refs., 56 figs., 16 tabs.

  20. Predictors for perioperative blood transfusion in elderly patients with extra capsular hip fractures treated with cephalo-medullary nailing.

    Science.gov (United States)

    Fazal, M Ali; Bagley, Caroline; Garg, Parag

    2018-02-01

    The aim of our study was to determine predictive factors and requirement for perioperative blood transfusion in elderly patients with extra capsular hip fractures treated with cephalo-medullary device. Seventy-nine patients with extra capsular hip fractures treated with cephalo-medullary nailing were included in the study. Age, sex, ASA grade, timing of surgery, preoperative and postoperative haemoglobin, length of hospital stay, fracture type, number of units transfused and 30-day mortality were recorded. The mean age was 82.3 years. Forty-seven patients underwent a short nail and 32 patients a long nail; 53.4% patients required blood transfusion postoperatively. Transfusion was required in 71.8% of the long nails (p  0.05). Length of hospital stay in non-transfusion group was 13 days and in transfusion group was 19 days (p  0.05). Thirty-day mortality in patients needing blood transfusion was 5% and in non-transfusion group was 3.7% (p > 0.05). Patient age, ASA grade, preoperative haemoglobin and length of nail are reliable predictors for perioperative blood transfusion in extra capsular hip fractures in elderly patients treated with cephalo-medullary nailing and reinforce a selective transfusion policy. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  1. Autologous Collagen Matrix (ACM): Lower Pole Support With a Supero-Anterior Capsular Flap in Secondary Subpectoral Breast Augmentation.

    Science.gov (United States)

    Montemurro, Paolo; Cheema, Mubashir; Hedén, Per; Avvedimento, Stefano; Agko, Mouchammed; Quattrini Li, Alessandro

    2017-05-01

    Secondary aesthetic breast surgery is a complex and challenging scenario. It requires the surgeon to identify contributing factors, provide patient education, make a further management plan, and optimize the conditions for a favorable result. Various techniques have been described in literature but the rate of reoperation is still high. The first author has been using a supero-anterior capsular flap with a neopectoral subcapsular pocket and an implant change in these cases. To review the patient characteristics, indications, and early results of using part of the existing implant capsule for secondary subpectoral breast augmentations. All patients who underwent secondary breast augmentation, over a period of 2 years by the first author (P.M.), using the supero-anterior capsular flap technique were included. The technique involves dissection of a new subpectoral pocket and uses the existing implant capsule as an internal brassiere. A total of 36 patients were operated by this technique. Of these, 17 patients had developed a complication while 19 patients wanted a change in size only. At a mean follow up of 10.2 months, there was no bottoming out, double bubble, or capsular contracture. This reliable technique provides stable results as shown by low rate of complications with the existing follow up. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  2. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    Science.gov (United States)

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  3. Medical management of bilateral corneal opacity in an Asian elephant (Elephas maximus: A case report

    Directory of Open Access Journals (Sweden)

    Pranab Paul

    2018-03-01

    Full Text Available Objective: This study was aimed at studying efficacy of medical management of corneal opacity in an Asian elephant (Elephas maximus. Material and methods: A 42 years old male Asian elephant was brought to the Teaching Veterinary Hospital (TVH at Chittagong Veterinary and Animal Sciences University (CVASU with a history of chronic lacrimation and impaired vision. On clinical examination, the animal was found apparently healthy. Opthalmological examination tentatively revealed the condition as corneal opacity. The left eye was much more affected as compared to the right one. Medical management was instituted with topical administration of ciprofloxacin, dexamethasone, subconjunctival prednisolone and dexamethasone along with intramuscular ketoprofen (at 1 mg/Kg bwt and vitamin A (at 5000 IU/Kg bwt. Results: The “mahout” (elepenat caretaker of the elephant was kept in close contact over cell phone to follow up the progress of the condition. Clinical examination after 19 days revealed complete recovery of the cornel opacity. There was no sign of lacrimation and the animal regained its normal vision. Conclusion: The treatment protocol successfully eliminated the discomfort along with corneal opacity and lacrimation in an Asian elephant. [J Adv Vet Anim Res 2018; 5(1.000: 98-100

  4. OPAC Design Enhancements and Their Effects on Circulation and Resource Sharing within the Library Consortium Environment

    Directory of Open Access Journals (Sweden)

    Michael J. Bennett

    2007-03-01

    Full Text Available A longitudinal study of three discrete online public access catalog (OPAC design enhancements examined the possible effects such changes may have on circulation and resource sharing within the automated library consortium environment. Statistical comparisons were made of both circulation and interlibrary loan (ILL figures from the year before enhancement to the year after implementation. Data from sixteen libraries covering a seven-year period were studied in order to determine the degree to which patrons may or may not utilize increasingly broader OPAC ILL options over time. Results indicated that while ILL totals increased significantly after each OPAC enhancement, such gains did not result in significant corresponding changes in total circulation.

  5. Complications of cataract surgery in eyes filled with silicone oil.

    Science.gov (United States)

    Kanclerz, Piotr; Grzybowski, Andrzej; Schwartz, Stephen G; Lipowski, Paweł

    2018-03-01

    The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil. This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal. In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed. In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

  6. A multiplex PCR assay for molecular capsular serotyping of Mannheimia haemolytica serotypes 1, 2, and 6

    Science.gov (United States)

    Mannheimia haemolytica is an important respiratory pathogen of ruminants. Of the 12 capsular serovars identified, 1 and 6 are most frequently associated with disease in cattle, while 2 is largely a commensal. Comparative analysis of 24 M. haemolytica genomes was used to identify unique genes associa...

  7. Antibody response to Haemophilus influenzae type b capsular polysaccharide conjugated to tetanus toxoid in preterm infants

    DEFF Research Database (Denmark)

    Kristensen, Kim; Gyhrs, A; Lausen, B

    1996-01-01

    OBJECTIVE: To evaluate the antibody response to a Haemophilus influenzae type b capsular polysaccharide (HibCP) tetanus toxoid (TT) conjugate vaccine (HibCP-TT) in preterm infants. SUBJECTS: Thirty-five healthy preterm infants with gestational ages (GA) from 27 to 36 weeks and birth weights from...

  8. 23-gauge vitrectomy with intraocular foreign body removal via the limbus: An alternative approach for select cases

    Directory of Open Access Journals (Sweden)

    Ramandeep Singh

    2014-01-01

    Full Text Available Purpose: To study the outcome of removal of retained intraocular foreign bodies (RIOFBs via limbus using 23-gauge transconjunctival sutureless vitrectomy (TSV. Materials and Methods: In this prospective, non-comparative interventional case series, fourteen eyes of 14 patients fulfilling the inclusion criteria were enrolled. They underwent 23-gauge TSV for management of posterior segment RIOFB and reviewed at 1 day, 7 days, 6 weeks, 3, 6 and 12 months. Eyes with penetrating eye injury involving cornea or limbus (corneal injury not so severe to hinder vitrectomy, cataract associated with anterior and/or posterior capsular tear requiring cataract surgery and posterior segment RIOFB with minimal posterior segment involvement were included. Main outcome measures include success in removal of RIOFB without enlarging sclerotomy, ability to preserve capsular support, improvement in visual acuity and complications, if any. Results: All eyes underwent the successful RIOFB removal through limbal port without enlarging scleral ports. None of the eyes required suturing of the sclera, cornea or conjunctiva. Anterior capsular rim could be preserved in all eyes except one. Postoperatively follow up ranged from one year in 8, 6 months in 4 and 3 months in 2 eyes. The mean logMAR visual acuity at 3, 6, and 12 months showed significant improvement. There were no intraoperative complications. Postoperative complications include microscopic hyphema and loose blood in vitreous cavity in one eye. Conclusion: The advantages of 23-gauge TSV for removal of RIOFB may be passed on to select cases. RIOFB removal through limbal route obviated the need for scleral port enlargement and preserved capsular support for early visual rehabilitation.

  9. Effect of Biodiesel of Spent Cooking Oil Addition at Diesel Fuel to Opacity and Gas Emission Throw Away of CO, CO2 and HC

    International Nuclear Information System (INIS)

    Setyadji, Moch; Endang Susiantini

    2007-01-01

    Investigation of biodiesel spent cooking oil addition effect at diesel fuel to opacity and gas emission throw away on various engine rotation speed has been done. The variables observed were fuel specific used i.e. pure diesel fuel, biodiesel mix 5% (B5), mix 10% (B10), mix 15% (B15), mix 20% (B20) and engine rotation speed. Gas emission throw away observed were CO, CO 2 , HC and opacity. Opacity and gas emission throwaway were observed by Opacity Sagem apparatus and gas analyzer. Result of experiment showed that biodiesel addition at diesel fuel was very decreasing opacity and gas emission throw away. The opacity lowest on B20, gas emission throw away lowest of CO on B10, CO 2 on B10 and HC on B20. (author)

  10. An Analysis of Source Tilting and Sub-cell Opacity Sampling for IMC

    Energy Technology Data Exchange (ETDEWEB)

    Wollaeger, Ryan T. [Los Alamos National Laboratory; Urbatsch, Todd J. [Los Alamos National Laboratory; Wollaber, Allan B. [Los Alamos National Laboratory; Densmore, Jeffery D. [Los Alamos National Laboratory

    2012-08-02

    Implicit Monte Carlo (IMC) is a stochastic method for solving the radiative transfer equations for multiphysics application with the material in local thermodynamic equilibrium. The IMC method employs a fictitious scattering term that is computed from an implicit discretization of the material temperature equation. Unfortunately, the original histogram representation of the temperature and opacity with respect to the spatial domain leads to nonphysically fast propagation of radiation waves through optically thick material. In the past, heuristic source tilting schemes have been used to mitigate the numerical teleportation error of the radiation particles in IMC that cause this overly rapid radiation wave propagation. While improving the material temperature profile throughout the time duration, these tilting schemes alone do not generally alleviate the teleportation error to suitable levels. Another means of potentially reducing teleportation error in IMC is implementing continuous sub-cell opacities based on sub-cell temperature profiles. We present here an analysis of source tilting and continuous sub-cell opacity sampling applied to various discretizations of the temperature equation. Through this analysis, we demonstrate that applying both heuristics does not necessarily yield more accurate results if the discretization of the material equation is inconsistent with the Monte Carlo sub-cell transport.

  11. Detection of artificial air space opacities with digital radiography. Ex vivo study on enhanced latitude post-processing

    International Nuclear Information System (INIS)

    Biederer, Juergen; Bolte, H.; Schmidt, T.; Charalambous, N.; Both, M.; Hoffmann, B.; Heller, M.; Kopp, U.; Freitag-Wolf, S.; Van Metter, R.

    2010-01-01

    Purpose: To evaluate in a.-p. digital chest radiograms of an ex vivo system if increased latitude and enhanced image detail contrast (EVP) improve the accuracy of detecting artificial air space opacities in parts of the lung that are superimposed by the diaphragm. Materials and Methods: 19 porcine lungs were inflated inside a chest phantom, prepared with 20-50 ml gelatin-stabilized liquid to generate alveolar air space opacities, and examined with direct radiography (3.0 x 2.5 k detector/125 kVp/4 mAs). 276 a.-p. images with and without EVP of 1.0-3.0 were presented to 6 observers. 8 regions were read for opacities, the reference was defined by CT. Statistics included sensitivity/specificity, interobserver variability, and calculation of Az (area under ROC curve). Results: Behind the diaphragm (opacities in 32/92 regions), the median sensitivity increased from 0.35 without EVP to 0.53 - 0.56 at EVP 1.5 - 3.0 (significant in 5/6 observers). The specificity decreased from 0.96 to 0.90 (significant in 6/6), and the Az value and interobserver correlation increased from 0.66 to 0.74 and 0.39 to 0.48, respectively. Above the diaphragm, the median sensitivity for artificial opacities (136/276 regions) increased from 0.71 to 0.77 - 0.82 with EVP (significant in 4/6 observers). The specificity and Az value decreased from 0.76 to 0.62 and 0.74 to 0.70, respectively, (significant in 3/6). Conclusion: In this ex vivo experiment, EVP improved the diagnostic accuracy for artificial air space opacities in the superimposed parts of the lung (area under the ROC curve). Above the diaphragm, the accuracy was not affected due to a tradeoff in sensitivity/specificity. (orig.)

  12. Arthroscopic Bankart repair and capsular shift for recurrent anterior shoulder instability: functional outcomes and identification of risk factors for recurrence.

    Science.gov (United States)

    Ahmed, Issaq; Ashton, Fiona; Robinson, Christopher Michael

    2012-07-18

    Arthroscopic Bankart repair and capsular shift is a well-established technique for the treatment of anterior shoulder instability. The purpose of this study was to evaluate the outcomes following arthroscopic Bankart repair and capsular shift and to identify risk factors that are predictive of recurrence of glenohumeral instability. We performed a retrospective review of a prospectively collected database consisting of 302 patients who had undergone arthroscopic Bankart repair and capsular shift for the treatment of recurrent anterior glenohumeral instability. The prevalence of patient and injury-related risk factors for recurrence was assessed. Cox proportional hazards models were used to estimate the predicted probability of recurrence within two years. The chief outcome measures were the risk of recurrence and the two-year functional outcomes assessed with the Western Ontario shoulder instability index (WOSI) and disabilities of the arm, shoulder and hand (DASH) scores. The rate of recurrent glenohumeral instability after arthroscopic Bankart repair and capsular shift was 13.2%. The median time to recurrence was twelve months, and this complication developed within one year in 55% of these patients. The risk of recurrence was independently predicted by the patient's age at surgery, the severity of glenoid bone loss, and the presence of an engaging Hill-Sachs lesion (all p surgery. Varying the cutoff level for the predicted probability of recurrence in the model from 50% to lower values increased the sensitivity of the model to detect recurrences but decreased the positive predictive value of the model to correctly predict failed repairs. There was a significant improvement in the mean WOSI and DASH scores at two years postoperatively (both p instability and individualizing treatment options for particular groups of patients. Prognostic level I. See Instructions for authors for a complete description of levels of evidence.

  13. In-the-bag capsular tension ring and intraocular lens subluxation or dislocation: a series of 23 cases.

    Science.gov (United States)

    Werner, Liliana; Zaugg, Brian; Neuhann, Tobias; Burrow, Michael; Tetz, Manfred

    2012-02-01

    To describe clinical and pathologic findings from cases of in-the-bag capsular tension ring (CTR) and intraocular lens (IOL) subluxation or dislocation. Retrospective case series with clinicopathologic correlation. Twenty-three explanted subluxated/dislocated capsular bags containing a CTR and an IOL explanted in Europe and submitted in fixative to the Berlin Eye Research Institute. Standard gross and light microscopy of specimens, complete histopathologic analyses of selected specimens done at the University of Utah, as well as questionnaire sent to explanting surgeons, and patient chart review, when available. Lens design, material, and abnormalities, capsular bag anomalies, patient demographic data, surgical dates, and presence or absence of known risk factors. Patients were aged 76.31 ± 8.24 years at explantation, which was performed 81.5 ± 32.2 months after implantation. The IOLs in these cases were 3-piece hydrophobic acrylic (N = 11), 1-piece hydrophobic acrylic (n = 6), 3-piece silicone (n = 4), or 1-piece hydrophilic acrylic (n = 2) designs; all CTRs were made of poly(methyl methacrylate). Available information on associated ocular conditions included pseudoexfoliation (n = 17), glaucoma (n = 4), vitrectomy/retina surgery (n = 3), and trauma (n = 1). Complete histopathologic assessment in 3 specimens showed signs consistent with pseudoexfoliation, without available history related to this condition in one of the cases. Moderate/severe degrees of Soemmering's ring formation and capsulorhexis phimosis were observed or reported in 13 and 11 specimens, respectively. Fourteen eyes were implanted and explanted by the same surgeon, with an interval of 92.7 ± 23.4 months between the procedures. His rate of explantation because of subluxation/dislocation was 0.76% of the CTRs implanted during the time considered. Explantation because of postoperative subluxation or dislocation of CTR-IOL-capsular bag complexes occurred approximately 6.8 years after implantation

  14. Experimental study of self-backlighting method for opacity

    International Nuclear Information System (INIS)

    Ding Yaonan; Yang Jiamin; Li Sanwei; Cao Leifeng; Wang Yaomei; Zhang Wenhai; Chen Bo; Yu Yanning; Wang Hongbin

    2001-01-01

    Self-backlighting method for opacity measurement has been suggested and studied, based on the actual condition of Xingguang II laser facility. An 80 J and 350 nm laser, which has a duration of about 700 ps, irradiates on a newly designed target and creates intense X-ray radiation acting as both heating source and backlighter source. The heated sample has been spatially imaged to obtain X-ray spectra from X-ray source region, transmission region and self-emission region of the sample at the same shot by spatially resolved transmission grating spectrometer in which dispersed X-ray is recorded by X-ray CCD. The samples are low-Z CH foam with density of 0.042 g/cm 3 , thickness of 42 μm and mid-Z Al with density of 2.7 g/cm 3 , thickness of 0.5 μm or 1.0 μm. Mass absorption coefficients of the heated sample as function of the photon energy have been obtained experimentally in the same shot. The spectra line emitted from the heated CH foam has also been measured by OHM crystal spectrometer, which has been used to determine the temperature of the sample. The experimental results for opacity of carbon have been discussed

  15. The risk of capsular breakage from phacoemulsification needle contact with the lens capsule: a laboratory study.

    Science.gov (United States)

    Meyer, Jay J; Kuo, Annie F; Olson, Randall J

    2010-06-01

    To determine capsular breakage risk from contact by phacoemulsification needles by machine and tip type. Experimental laboratory investigation. Infiniti (Alcon, Inc.) with Intrepid cartridges and Signature (Abbott Medical Optics, Inc.) phacoemulsification machines were tested using 19- and 20-gauge sharp and rounded tips. Actual and unoccluded flow vacuum were determined at 550 mm Hg, bottle height of 75 cm, and machine-indicated flow rate of 60 mL/minute. Breakage from brief tip contact with a capsular surrogate and human cadaveric lenses was calculated. Nineteen-gauge tips had more flow and less unoccluded flow vacuum than 20-gauge tips for both machines, with highest unoccluded flow vacuum in the Infiniti. The 19-gauge sharp tip was more likely than the 20-gauge sharp tip to cause surrogate breakage for Signature with micropulse and Ellips (Abbott Medical Optics, Inc.) ultrasound at 100% power. For Infiniti using OZil (Alcon, Inc.) ultrasound, 20-gauge sharp tips were more likely than 19-gauge sharp tips to break the membrane. For cadaveric lenses, using rounded 20-gauge tips at 100% power, breakage rates were micropulse (2.3%), Ellips (2.3%), OZil (5.3%). Breakage rates for sharp 20-gauge Ellips tips were higher than for rounded tips. Factors influencing capsular breakage may include active vacuum at the tip, flow rate, needle gauge, and sharpness. Nineteen-gauge sharp tips were more likely than 20-gauge tips to cause breakage in lower vacuum methods. For higher-vacuum methods, breakage is more likely with 20-gauge than with 19-gauge tips. Rounded-edge tips are less likely than sharp-edged tips to cause breakage. Copyright 2010 Elsevier Inc. All rights reserved.

  16. Opacity Build-up in Impulsive Relativistic Sources

    International Nuclear Information System (INIS)

    Granot, Jonathan; Cohen-Tanugi, Johann; Silva, Eduardo do Couto e

    2007-01-01

    Opacity effects in relativistic sources of high-energy gamma-rays, such as gamma-ray bursts (GRBs) or Blazars, can probe the Lorentz factor of the outflow as well as the distance of the emission site from the source, and thus help constrain the composition of the outflow (protons, pairs, magnetic field) and the emission mechanism. Most previous works consider the opacity in steady state. Here we study the effects of the time dependence of the opacity to pair production (γγ → e + e - ) in an impulsive relativistic source, which may be relevant for the prompt gamma-ray emission in GRBs or flares in Blazars. We present a simple, yet rich, semi-analytic model for the time and energy dependence of the optical depth, τγγ, in which a thin spherical shell expands ultra-relativistically and emits isotropically in its own rest frame over a finite range of radii, R 0 (le) R (le) R 0 +ΔR. This is particularly relevant for GRB internal shocks. We find that in an impulsive source (ΔR ∼ 0 ), while the instantaneous spectrum (which is typically hard to measure due to poor photon statistics) has an exponential cutoff above the photon energy (var e psilon)1(T) where tγγ((var e psilon)1) = 1, the time integrated spectrum (which is easier to measure) has a power-law high-energy tail above the photon energy (var e psilon)1* ∼ (var e psilon)1(ΔT) where ΔT is the duration of the emission episode. Furthermore, photons with energies (var e psilon) > (var e psilon)1* are expected to arrive mainly near the onset of the spike in the light curve or flare, which corresponds to the short emission episode. This arises since in such impulsive sources it takes time to build-up the (target) photon field, and thus the optical depth τγγ((var e psilon)) initially increases with time and (var e psilon)1(T) correspondingly decreases with time, so that photons of energy (var e psilon) > (var e psilon)1* are able to escape the source mainly very early on while (var e psilon)1(T) > (var

  17. Predictors for perioperative blood transfusion in elderly patients with extra capsular hip fractures treated with cephalo-medullary nailing

    Directory of Open Access Journals (Sweden)

    M. Ali Fazal

    2018-02-01

    Conclusion: Patient age, ASA grade, preoperative haemoglobin and length of nail are reliable predictors for perioperative blood transfusion in extra capsular hip fractures in elderly patients treated with cephalo-medullary nailing and reinforce a selective transfusion policy.

  18. Gray and multigroup radiation transport models for two-dimensional binary stochastic media using effective opacities

    International Nuclear Information System (INIS)

    Olson, Gordon L.

    2016-01-01

    One-dimensional models for the transport of radiation through binary stochastic media do not work in multi-dimensions. Authors have attempted to modify or extend the 1D models to work in multidimensions without success. Analytic one-dimensional models are successful in 1D only when assuming greatly simplified physics. State of the art theories for stochastic media radiation transport do not address multi-dimensions and temperature-dependent physics coefficients. Here, the concept of effective opacities and effective heat capacities is found to well represent the ensemble averaged transport solutions in cases with gray or multigroup temperature-dependent opacities and constant or temperature-dependent heat capacities. In every case analyzed here, effective physics coefficients fit the transport solutions over a useful range of parameter space. The transport equation is solved with the spherical harmonics method with angle orders of n=1 and 5. Although the details depend on what order of solution is used, the general results are similar, independent of angular order. - Highlights: • Gray and multigroup radiation transport is done through 2D stochastic media. • Approximate models for the mean radiation field are found for all test problems. • Effective opacities are adjusted to fit the means of stochastic media transport. • Test problems include temperature dependent opacities and heat capacities • Transport solutions are done with angle orders n=1 and 5.

  19. Studies of the experimental technologies of radiative opacity

    International Nuclear Information System (INIS)

    Zhang Jiyan; Yang Guohong; Ding Yaonan; Yang Jiamin; Li Jun; Zhang Wenhai; He Yingling; Wang Yaomei; Huang Haodong

    2004-12-01

    On the SHENGUANG-II laser facility, integrated experiment for opacity measurement was performed and related physical items were studies. In the experiment, some new-typed diagnosing device were also tested. The experiment includes three contents: (1) Investigation of the measurement technique of absorption spectra in the keV region; (2) Investigation of the measurement technique of dual point projection spectroscopy; (3) Investigation of the temperature and density parameters of the experimental samples. (authors)

  20. Genome wide gene expression analysis of the posterior capsule in patients with osteoarthritis and knee flexion contracture.

    Science.gov (United States)

    Campbell, Thomas Mark; Trudel, Guy; Wong, Kayleigh Kristin; Laneuville, Odette

    2014-11-01

    Knee flexion contractures (KFC) are limitations in the ability to fully extend the knee joint. In people with knee osteoarthritis (OA), KFC are common, impair function, and worsen outcomes after arthroplasty. In KFC, the posterior knee capsule is believed to play a key role, but the pathophysiology remains poorly understood. We sought to identify gene expression differences in the posterior knee capsule of patients with OA with and without KFC. Capsule tissue was obtained from the knees of 12 subjects diagnosed with advanced-stage OA at the time of knee arthroplasty surgery. The presence or absence of KFC allocated patients into 2 groups using a case-control design. Genomewide capsular gene expression was compared between the 2 patient groups. Confirmation of differential expression of the corresponding proteins was performed by immunohistochemistry on tissue sections. There were no significant demographic differences between the patients with OA with KFC and without KFC save for reduced extension in their surgical knee (pKFC patients showed a 6.4-fold decrease in CSN1S1 (p=0.017) gene expression and a 3.7-, 2.0-, and 2.6-fold increase in CHAD, Sox9, and Cyr61 gene expression, respectively (p=0.001, 0.004, 0.001, respectively). There were corresponding increases in protein levels for chondroadherin, sex determining region Y-box 9, and casein alphaS1 (all pKFC exhibited differential expression of 4 genes all previously documented to be associated with tissue fibrosis.

  1. Short-term outcomes of small incision cataract surgery provided by a regional population in the Pacific.

    Science.gov (United States)

    Bhikoo, Riyaz; Vellara, Hans; Lolokabaira, Salome; Murray, Neil; Sikivou, Biu; McGhee, Charles

    2017-11-01

    This study aims to describe patient demographics, visual and surgical outcomes of a cohort undergoing small incision cataract surgery at a Pacific regional ophthalmic training facility. This is a prospective, longitudinal study conducted at the Pacific Eye Institute, Fiji. One hundred fifty-six patients underwent small incision cataract surgery. Preoperatively, a complete ophthalmic examination, including pachymetry and macular optical coherence tomography performed by two independent investigators. Temporal small incision cataract surgery with intraocular lens insertion was performed by ophthalmologists, and trainee ophthalmologists. Follow-up occurred at day one, four weeks and 3 months. Patient characteristics, visual outcomes including surgically induced astigmatism and complications. Ninety-one per cent (142/156) attended 3-month follow-up with median age 63 years (range 19-82), 52% female (81/156) and 58% (90/156) Fijian ethnicity. In 37% (57/156), the contralateral eye was pseudophakic. Mean preoperative best spectacle-corrected visual acuity was logMAR 1.44 (6/165). At 3 months, 74% (105/142) achieved ≥6/18 unaided vision (94% [133/142] best spectacle-corrected visual acuity). Mean postoperative spherical equivalent was -0.78 (SD 0.95) D and mean surgically induced astigmatism 1.04 (0.57) D. Complications included posterior capsular rupture with vitreous loss (4% [6/156]), optical coherence tomography confirmed macular oedema (8% [12/152] at 4 weeks), significant posterior capsular opacity (23% [31/136]) and >5% increase in preoperative pachymetry (1% [1/142]) at 3 months. Reduction in preoperative best spectacle-corrected visual acuity occurred in 2% (3/142). No cases of endophthalmitis. Small incision cataract surgery provided to a regional population is effective with 94% achieving the World Health Organisation's definition of 'Good Vision' (≥6/18). Refinements in biometric and surgical techniques may allow a greater proportion of patients to

  2. Antibiotic modulation of capsular exopolysaccharide and virulence in Acinetobacter baumannii.

    Directory of Open Access Journals (Sweden)

    Edward Geisinger

    2015-02-01

    Full Text Available Acinetobacter baumannii is an opportunistic pathogen of increasing importance due to its propensity for intractable multidrug-resistant infections in hospitals. All clinical isolates examined contain a conserved gene cluster, the K locus, which determines the production of complex polysaccharides, including an exopolysaccharide capsule known to protect against killing by host serum and to increase virulence in animal models of infection. Whether the polysaccharides determined by the K locus contribute to intrinsic defenses against antibiotics is unknown. We demonstrate here that mutants deficient in the exopolysaccharide capsule have lowered intrinsic resistance to peptide antibiotics, while a mutation affecting sugar precursors involved in both capsule and lipopolysaccharide synthesis sensitizes the bacterium to multiple antibiotic classes. We observed that, when grown in the presence of certain antibiotics below their MIC, including the translation inhibitors chloramphenicol and erythromycin, A. baumannii increases production of the K locus exopolysaccharide. Hyperproduction of capsular exopolysaccharide is reversible and non-mutational, and occurs concomitantly with increased resistance to the inducing antibiotic that is independent of the presence of the K locus. Strikingly, antibiotic-enhanced capsular exopolysaccharide production confers increased resistance to killing by host complement and increases virulence in a mouse model of systemic infection. Finally, we show that augmented capsule production upon antibiotic exposure is facilitated by transcriptional increases in K locus gene expression that are dependent on a two-component regulatory system, bfmRS. These studies reveal that the synthesis of capsule, a major pathogenicity determinant, is regulated in response to antibiotic stress. Our data are consistent with a model in which gene expression changes triggered by ineffectual antibiotic treatment cause A. baumannii to transition

  3. Corneal Opacity in Domestic Ducks Experimentally Infected With H5N1 Highly Pathogenic Avian Influenza Virus.

    Science.gov (United States)

    Yamamoto, Y; Nakamura, K; Yamada, M; Mase, M

    2016-01-01

    Domestic ducks can be a key factor in the regional spread of H5N1 highly pathogenic avian influenza (HPAI) virus in Asia. The authors performed experimental infections to examine the relationship between corneal opacity and H5N1 HPAI virus infection in domestic ducks (Anas platyrhyncha var domestica). A total of 99 domestic ducks, including 3 control birds, were used in the study. In experiment 1, when domestic ducks were inoculated intranasally with 2 H5N1 HPAI viruses, corneal opacity appeared more frequently than neurologic signs and mortality. Corneal ulceration and exophthalmos were rare findings. Histopathologic examinations of the eyes of domestic ducks in experiment 2 revealed that corneal opacity was due to the loss of corneal endothelial cells and subsequent keratitis with edema. Influenza viral antigen was detected in corneal endothelial cells and some other ocular cells by immunohistochemistry. Results suggest that corneal opacity is a characteristic and frequent finding in domestic ducks infected with the H5N1 HPAI virus. Confirming this ocular change may improve the detection rate of infected domestic ducks in the field. © The Author(s) 2015.

  4. Nuclear opacity for neutrinos at small Q2

    International Nuclear Information System (INIS)

    Kopeliovich, B.Z.

    1989-01-01

    The causes of nuclear screening of the vector and the weak axial currents are quite different. The hadronic fluctuations of neutrino in the nuclear matter live much longer than in the vacuum, due to interaction with nucleons. Nuclear opacity for neutrinos calculated using Glauber-Gribov theory, differs considerably from that given by the Bell optical model. A good agreement of the theory with the recent BEBC WA59 Collaboration measurements is found. 14 refs.; 4 figs

  5. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    OpenAIRE

    Liang-Nan Sun; Bai-Jun Li; Yuan-Fei Zhu; Xin-Hua Liu

    2017-01-01

    AIM: To evaluate the clinical results of capsular tension ring(CTR)implantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyes)with congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOL)implantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperati...

  6. Designing the OPAC User Interface to Improve Access and Retrieval.

    Science.gov (United States)

    Basista, Thomas; And Others

    1991-01-01

    Discussion of problems with retrieval of records in library online public access catalogs (OPACs) focuses on an ongoing research project at the Indiana University of Pennsylvania (IUP) that has been trying to improve subject retrieval vocabulary control using natural and thesaural language and on the design of a good graphical user interface.…

  7. Controlled opacity in a class of nonlinear dielectric media

    Science.gov (United States)

    Bittencourt, E.; Camargo, G. H. S.; De Lorenci, V. A.; Klippert, R.

    2017-03-01

    Motivated by new technologies for designing and tailoring metamaterials, we seek properties for certain classes of nonlinear optical materials that allow room for a reversibly controlled opacity-to-transparency phase transition through the application of external electromagnetic fields. We examine some mathematically simple models for the dielectric parameters of the medium and compute the relevant geometric quantities that describe the speed and polarization of light rays.

  8. Capsular polysaccharide typing of domestic mastitis-causing Staphylococcus aureus strains and its potential exploration of bovine mastitis vaccine development. I. Capsular polysaccharide typing, isolation and purification of the strains.

    Science.gov (United States)

    Han, H R; Pak, S I; Kang, S W; Jong, W S; Youn, C J

    2000-06-01

    One hundred seven isolates of Staphylococcus aureus from bovine mastitis were investigated for colony morphology in serum-soft agar (SSA), autoagglutination in salt, and capsular serotype. Capsular polysaccharide (CP) was purified and quantified from the extracts of clinical isolates. Overall, 89 isolates (83.2%) were diffuse in the SSA, without any difference in the proportion of diffuse colony between type 5 and type 8 strains. Some strains exhibited compact colonies in the SSA and expressed CP as determined by an enzyme-linked immunosorbent assay, indicating that compact morphology does not exclude encapsulation. The majority of the strains (11/12) showed autoagglutination in the salt aggregation test. The serotype 336 accounted for 46.7% of the isolates followed by serotype 5 (12.1%) and serotype 8 (12.1%). Particularly, twenty-six (24.3%) isolates reacted with two serotypes; 7 for type 8/336 and 19 for type 5/336. Five isolates (4.7%) were nontypeable with monoclonal antibodies specific for CP serotype 5, 8, or 336. The CP concentration in culture supernatants varied with the serotypes, and the total amount of CP produced by cells grown in a liquid medium was much less than that produced by cells grown on a solid medium. The Western blotting indicated that the CP bands of S. aureus serotype 5 and 8 were ranged in the molecular mass of 58-84 kilodalton (kDa), with additional bands in the region of approximately >/= 48 or

  9. Epistemic Opacity, Confirmation Holism and Technical Debt: Computer Simulation in the Light of Empirical Software Engineering

    OpenAIRE

    Newman , Julian

    2015-01-01

    Epistemic opacity vis a vis human agents has been presented as an essential, ineliminable characteristic of computer simulation models resulting from the characteristics of the human cognitive agent. This paper argues, on the contrary, that such epistemic opacity as does occur in computer simulations is not a consequence of human limitations but of a failure on the part of model developers to adopt good software engineering practice for managing human error and ensuring the software artefact ...

  10. Features of YAG-laser treatment of posterior capsule opacification in eyes with intraocular comorbidities ext

    Directory of Open Access Journals (Sweden)

    O. I. Borzunov

    2015-01-01

    Full Text Available Purpose: is to evaluate the effectiveness of YAG laser posterior lens capsule dissection in patients with secondary cataract with concurrent intraocular pathology. Patients and methods: retro- and prospective analysis of the results of the YAG — laser treatment of secondary cataract in the 196 eyes, including the intraocular concomitant pathology (myopia, glaucoma, age-related macular degeneration, diabetic retinopathy, retinitis pigmentosa operated retinal detachment, chronic uveitis in remission, peripheral chorioretinal degeneration. Effectiveness of treatment was evaluated by checking visual acuity and dynamics of complaints as aberration, glare, distortion in the central field of view without proper disease of the macula. Complex preoperative studies included: refractometry, visometry with correction, perimetry, tonometry, biomicroscopy, ophthalmoscopy, ultrasound examination of the eyeball (if necessary. The examination results should demonstrate convincing evidence that posterior capsular opacification is the main reason for the decrease of visual acuity. Results:, Visual acuity, at average increased from 0.4‑0.6 to 0.8‑1.0 in 50 cases after dissection, Visual acuity improved to 2‑3 lines in 66‑4–5, 24‑6‑7 lines in 74 cases. Visual acuity remains the same, but contrast sensitivity was increased in 6 cases. The IOL location after disruption was evaluated by β-scanning and biomicroscopy. In case of the initial correct IOL position in all 195 (100 % cases, there were no dislocation in the postoperative period. Complications that can be identified were single microcraters on the IOL surface in cases of its full contact with the posterior capsule. These injuries did not affect the visual functions.Conclusion: YAG -Laser dissection of secondary cataract is effective, less traumatic, and the optimal treatment of secondary cataract, including patients with concomitant intraocular pathology, and helps to avoid over

  11. Opportunities for Laboratory Opacity Chemistry Studies to Facilitate Characterization of Young Giant Planets and Brown Dwarfs

    Science.gov (United States)

    Marley, Mark; Freedman, Richard S.

    2015-01-01

    The thermal emission spectra of young giant planets is shaped by the opacity of atoms and molecules residing in their atmospheres. While great strides have been made in improving the opacities of important molecules, particularly NH3 and CH4, at high temperatures, much more work is needed to understand the opacity and chemistry of atomic Na and K. The highly pressure broadened fundamental band of Na and K in the optical stretches into the near-infrared, strongly influencing the shape of the Y and K spectral bands. Since young giant planets are bright in these bands it is important to understand the influences on the spectral shape. Discerning gravity and atmospheric composition is difficult, if not impossible, without both good atomic opacities as well as an excellent understanding of the relevant atmospheric chemistry. Since Na and K condense at temperatures near 500 to 600 K, the chemistry of the condensation process must be well understood as well, particularly any disequilibrium chemical pathways. Comparisons of the current generation of sophisticated atmospheric models and available data, however, reveal important shortcomings in the models. We will review the current state of observations and theory of young giant planets and will discuss these and other specific examples where improved laboratory measurements for alkali compounds have the potential of substantially improving our understanding of these atmospheres.

  12. Calculation of Free-Free Opacities

    Science.gov (United States)

    Bhatia, A. K.; Maiden, D.; Ritchie, A. B., Jr.

    2003-01-01

    Free-free absorption is an important contribution to the opacity for radiation transport through hot materials Temperatures can be as high as several keV, such that it becomes a computational challenge to solve the Schrodinger equation efficiently for rapidly oscillating continuum functions for high angular momenta. Several groups\\footnots, including ours, have studied the phase amplitude solution (PAS) of the Schrodinger equation, in which one solves equations for the wave function amplitude and phase, which are: smooth functions of the electron energy. It is also important to have an accurate Schroudinger benchmark for the development of the PAS method. We present results for dipole matrix elements, Gaunt factors, and cross sections for the absorption of radiation at various energies for Cs XIX at temperature=100 eV and density=0.187 g/cc for our newly developed PAS and Schrodinger benchmark.

  13. A test of lens opacity as an indicator of preclinical Alzheimer Disease.

    Science.gov (United States)

    Bei, Ling; Shui, Ying-Bo; Bai, Fang; Nelson, Suzanne K; Van Stavern, Gregory P; Beebe, David C

    2015-11-01

    Previous studies reported that characteristic lens opacities were present in Alzheimer Disease (AD) patients postmortem. We therefore determined whether cataract grade or lens opacity is related to the risk of Alzheimer dementia in participants who have biomarkers that predict a high risk of developing the disease. AD biomarker status was determined by positron emission tomography-Pittsburgh compound B (PET-PiB) imaging and cerebrospinal fluid (CSF) levels of Aβ42. Cognitively normal participants with a clinical dementia rating of zero (CDR = 0; N = 40) or with slight evidence of dementia (CDR = 0.5; N = 2) were recruited from longitudinal studies of memory and aging at the Washington University Knight Alzheimer's Disease Research Center. The age, sex, race, cataract type and cataract grade of all participants were recorded and an objective measure of lens light scattering was obtained for each eye using a Scheimpflug camera. Twenty-seven participants had no biomarkers of Alzheimer dementia and were CDR = 0. Fifteen participants had biomarkers indicating increased risk of AD, two of which were CDR = 0.5. Participants who were biomarker positive were older than those who were biomarker negative. Biomarker positive participants had more advanced cataracts and increased cortical light scattering, none of which reached statistical significance after adjustment for age. We conclude that cataract grade or lens opacity is unlikely to provide a non-invasive measure of the risk of developing Alzheimer dementia. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Statistical approach for calculating opacities of high-Z plasmas

    International Nuclear Information System (INIS)

    Nishikawa, Takeshi; Nakamura, Shinji; Takabe, Hideaki; Mima, Kunioki

    1992-01-01

    For simulating the X-ray radiation from laser produced high-Z plasma, an appropriate atomic modeling is necessary. Based on the average ion model, we have used a rather simple atomic model for opacity calculation in a hydrodynamic code and obtained a fairly good agreement with the experiment on the X-ray spectra from the laser-produced plasmas. We have investigated the accuracy of the atomic model used in the hydrodynamic code. It is found that transition energies of 4p-4d, 4d-4f, 4p-5d, 4d-5f and 4f-5g, which are important in laser produced high-Z plasma, can be given within an error of 15 % compared to the values by the Hartree-Fock-Slater (HFS) calculation and their oscillator strengths obtained by HFS calculation vary by a factor two according to the difference of charge state. We also propose a statistical method to carry out detail configuration accounting for electronic state by use of the population of bound electrons calculated with the average ion model. The statistical method is relatively simple and provides much improvement in calculating spectral opacities of line radiation, when we use the average ion model to determine electronic state. (author)

  15. Thermal shrinkage for shoulder instability.

    Science.gov (United States)

    Toth, Alison P; Warren, Russell F; Petrigliano, Frank A; Doward, David A; Cordasco, Frank A; Altchek, David W; O'Brien, Stephen J

    2011-07-01

    Thermal capsular shrinkage was popular for the treatment of shoulder instability, despite a paucity of outcomes data in the literature defining the indications for this procedure or supporting its long-term efficacy. The purpose of this study was to perform a clinical evaluation of radiofrequency thermal capsular shrinkage for the treatment of shoulder instability, with a minimum 2-year follow-up. From 1999 to 2001, 101 consecutive patients with mild to moderate shoulder instability underwent shoulder stabilization surgery with thermal capsular shrinkage using a monopolar radiofrequency device. Follow-up included a subjective outcome questionnaire, discussion of pain, instability, and activity level. Mean follow-up was 3.3 years (range 2.0-4.7 years). The thermal capsular shrinkage procedure failed due to instability and/or pain in 31% of shoulders at a mean time of 39 months. In patients with unidirectional anterior instability and those with concomitant labral repair, the procedure proved effective. Patients with multidirectional instability had moderate success. In contrast, four of five patients with isolated posterior instability failed. Thermal capsular shrinkage has been advocated for the treatment of shoulder instability, particularly mild to moderate capsular laxity. The ease of the procedure makes it attractive. However, our retrospective review revealed an overall failure rate of 31% in 80 patients with 2-year minimum follow-up. This mid- to long-term cohort study adds to the literature lacking support for thermal capsulorrhaphy in general, particularly posterior instability. The online version of this article (doi:10.1007/s11420-010-9187-7) contains supplementary material, which is available to authorized users.

  16. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation

    International Nuclear Information System (INIS)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson; Souza Junior, Arthur Soares; Moraes, Heleno Pinto de

    2003-01-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  17. Limb-darkening opacity experiment using a laser-heated plasma

    International Nuclear Information System (INIS)

    Hoffman, N.M.; Miller, L.W.; Mack, J.M.

    1978-10-01

    The limb-darkening technique, a method for measuring monochromatic opacity information, which has had successful astrophysical applications, is reviewed. The application of the technique to laser-produced plasmas in materials and regimes of temperature and density of interest to weapons designers is discussed, and the magnitude of the limb-darkening effect in such situations is estimated. Finally, an experimental study, now in progress, to evaluate the feasibility of this approach is described. 10 figures

  18. Capsular and thalamic infarction caused by tentorial herniation subsequent to head trauma

    International Nuclear Information System (INIS)

    Endo, M.; Ichikawa, F.; Miyasaka, Y.; Yada, K.; Ohwada, T.

    1991-01-01

    Five patients (4 male and 1 female) were observed to have capsular and thalamic infarction ascribed to descending transtentorial herniation (DTH) caused by head injury. A lucid interval immediately after the trauma and the presence of an epidural hematoma (EDH) characterized all five case. The low attenuation implicated the perforating arteries, that is the anterior thalamoperforating and anterior choroidal arteries, suggesting infarcted regions caused by occlusion of these arteries. Findings in the present study suggest that arterial occlusion in closed head injury may result from DTH. Moreover, infarction may be attributed to the delayed effects of injury. (orig./GDG)

  19. Posterior microphthalmos pigmentary retinopathy syndrome.

    Science.gov (United States)

    Pehere, Niranjan; Jalali, Subhadra; Deshmukh, Himanshu; Kannabiran, Chitra

    2011-04-01

    Posterior Microphthalmos Pigmentary Retinopathy Syndrome (PMPRS). Posterior microphthalmos (PM) is a relatively infrequent type of microphthalmos where posterior segment is predominantly affected with normal anterior segment measurements. Herein, we report two siblings with posterior microphthalmos retinopathy syndrome with postulated autosomal recessive mode of inheritance. A 13-year-old child had PM and retinitis pigmentosa (RP) and his 7-year-old sister had PM, RP, and foveoschisis. The genetics of this syndrome and variable phenotype is discussed. Importance of being aware of posterior microphthalmos and its posterior segment associations is highlighted.

  20. Configuration interaction effect on open M shell Fe and Ni LTE spectral opacities, Rosseland and Planck means

    International Nuclear Information System (INIS)

    Gilles, D; Busquet, M; Gilleron, F; Pain, J-C; Klapisch, M

    2016-01-01

    We have recently shown that iron and nickel open M-shell opacity spectra, up to Δn = 2 are very sensitive to Configuration Interaction (CI) treatments at temperature around 15 eV and for various densities. To do so we had compared extensive CI calculations obtained with two opacity codes HULLAC-v9 and SCO-RCG. In this work we extend these comparisons to a first evaluation of CI effects on Rosseland and Planck means. (paper)

  1. Echocardiographic Wall Motion Abnormality in Posterior Myocardial Infarction: The Diagnostic Value of Posterior Leads

    Directory of Open Access Journals (Sweden)

    A Darehzereshki

    2008-06-01

    Full Text Available Background: For the purpose of ascertaining myocardial infarction (MI and ischemia, the sensitivity of the initial 12-lead ECG is inadequate. It is risky to diagnose posterior MI using only precordial reciprocal changes, since the other leads may be more optimally positioned for the identification of electrocardiographic changes. In this study, we evaluated the relationship between electrocardiography changes and wall motion abnormalities in patients with posterior MI for earlier and better diagnosis of posterior MI.Methods: In this prospective cross-sectional study, we enrolled patients with posterior MI who had come to the Emergency Department of Shariati Hospital with their first episode of chest pain. A 12-lead surface electrocardiogram using posterior leads (V7-V9 was performed for all participants. Patients with ST elevation >0.05 mV or pathologic Q wave in the posterior leads, as well as those with specific changes indicating posterior MI in V1-V2, were evaluated by echocardiography in terms of wall motion abnormalities. All data were analyzed using SPSS and p<0.05 were considered statistically significant.Results: Of a total 79 patients enrolled, 48 (60.8% were men, and the mean age was 57.35±8.22 years. Smoking (54.4% and diabetes (48% were the most prevalent risk factors. In the echocardiographic evaluation, all patients had wall motion abnormalities in the left ventricle and 19 patients (24.1% had wall motion abnormalities in the right ventricle. The most frequent segment with motion abnormality among the all patients was the mid-posterior. The posterior leads showed better positive predictive value than the anterior leads for posterior wall motion abnormality.Conclusion: Electrocardiography of the posterior leads in patients with acute chest pain can help in earlier diagnosis and in time treatment of posterior MI.

  2. The Opacity of Russian-Ukrainian Energy Relations

    International Nuclear Information System (INIS)

    Dubien, A.

    2007-01-01

    Energy issues lie at the heart of Ukraine's economic, political and strategic challenges. A year after the 'orange revolution', the 'gas war' served to highlight the country's vulnerable position, being 80% dependent on imports of gas and having the world's most energy hungry economy. The 2005 crisis also highlighted the extreme opacity of the country's bilateral relations with Russia, which are governed as much by the interests surrounding Gazprom's relations as by those of the state. Yanukovich's return to power in the summer of 2006 coincided with a relative appeasement of relations with Moscow and a new division of spheres of influence in the Ukrainian energy sector. (author)

  3. Comparison of virulence factors and capsular types of Streptococcus agalactiae isolated from human and bovine infections.

    Science.gov (United States)

    Emaneini, Mohammad; Khoramian, Babak; Jabalameli, Fereshteh; Abani, Samira; Dabiri, Hossein; Beigverdi, Reza

    2016-02-01

    Streptococcus agalactiae is a leading cause of human and bovine infections. A total of 194 S. agalactiae isolates, 55 isolates from bovines and 139 from humans, were analyzed for capsular types, virulence genes (scpB, hly, rib, bca and bac) and mobile genetic elements (IS1548 and GBSi1) using polymerase chain reaction (PCR) and multiplex PCR. Capsular type III was predominant (61%), followed by types V, II, Ib, and IV. The scpB, hly, bca and bac virulence genes were only found among human isolates. Twelve and 2 distinct virulence gene profiles were identified among human and bovine isolates respectively. The virulence gene profiles scpB- hly- IS1548- rib-bca (51%) and scpB- hly- IS1548- bca (19%) were only predominant among human isolates. The rib gene was the most common virulence gene in both human and bovine isolates. The study showed a high prevalence of virulence genes in S. agalactiae strains isolated from human infections, these result can support the idea that S. agalactiae isolated from humans and bovines are generally unrelated and probably belonged to separate populations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Capsular glucan and intracellular glycogen of Mycobacterium tuberculosis: biosynthesis and impact on the persistence in mice

    DEFF Research Database (Denmark)

    Sambou, Tounkang; Dinadayala, Premkumar; Stadthagen, Gustavo

    2008-01-01

    Mycobacterium tuberculosis and other pathogenic mycobacterial species produce large amounts of a glycogen-like alpha-glucan that represents the major polysaccharide of their outermost capsular layer. To determine the role of the surface-exposed glucan in the physiology and virulence of these bact......Mycobacterium tuberculosis and other pathogenic mycobacterial species produce large amounts of a glycogen-like alpha-glucan that represents the major polysaccharide of their outermost capsular layer. To determine the role of the surface-exposed glucan in the physiology and virulence...... of these bacteria, orthologues of the glg genes involved in the biosynthesis of glycogen in Escherichia coli were identified in M. tuberculosis H37Rv and inactivated by allelic replacement. Biochemical analyses of the mutants and complemented strains indicated that the synthesis of glucan and glycogen involves...... the alpha-1,4-glucosyltransferases Rv3032 and GlgA (Rv1212c), the ADP-glucose pyrophosphorylase GlgC (Rv1213) and the branching enzyme GlgB (Rv1326c). Disruption of glgC reduced by half the glucan and glycogen contents of M. tuberculosis, whereas the inactivation of glgA and Rv3032 affected the production...

  5. Cataract in small animals: classification and treatment

    Directory of Open Access Journals (Sweden)

    Fahiano Montiani Ferreira

    1997-02-01

    Full Text Available Cataract means any opacity present in the lens, lens capsule or both. The opacities may vary in size, location, shape and rate of progression. By slit-lamp biomicroscopy it is possible to examine them with precision, determining its exact location and peculiarities, resulting in a safe, accurate diagnosis. Due to its variable origin and appearance, several methods of classification have been used. Classification by aetiology, grade of maturity, location and age of the patients are presented in this review. Surgical removal is the only effective therapy for this disease. Among the surgical techniques available to this day, endocapsular phacoemulsification excells for its better results, despite of its high cost, if compared to classical intra and extra capsular facectomies.

  6. Posterior fossa epidural hematoma

    International Nuclear Information System (INIS)

    Kushner, M.J.; Luken, M.G. III

    1983-01-01

    CT demonstrated posterior fossa epidural hematoma in three patients with head trauma in whom this diagnosis was not clinically apparent. No patient was in stupor or coma and no patient experienced a lucid interval. Only one patient had signs referable to the posterior fossa. Two patients had occipital skull fracture disclosed by plain radiographs. CT revealed a unilateral biconvex hematoma in two cases, and a bilateral hematoma with supratentorial extension in the third. All patients underwent suboccipital craniectomy and recovered. Therapeutic success in these cases was facilitated by early CT and the rapid disclosure of the unsuspected posterior fossa lesions. CT showing contiguous hematoma below and above the tentorium cerebelli after posterior head trauma is highly suggestive of epidural hematoma arising from the posterior fossa. (orig.)

  7. Analysis of irregular opacities of silicosis using computed tomography

    International Nuclear Information System (INIS)

    Maeda, Atsushi; Shida, Hisao; Chiyotani, Keizo; Saito, Kenichi; Mishina, Michihito

    1983-01-01

    Classification in used to codify Chest CT images of abnormalities of the lung in a simple reproducible manner. Simbols to record CT features of importance are listed. We applied CT to 92 cases of silicosis and roentgenological analysis was performed. Bullae, honeycombing, cavity, emphysema, pleural thickning and calcification were more clearly demonstrated in CT images than routine chest roentgenograms. Irregular opacities were considered to be a combined profusion of small round and streak or strand. (author)

  8. IRAS associations with dark clouds of opacity class 6

    International Nuclear Information System (INIS)

    Parker, N.D.

    1988-01-01

    Accurate positions of the opacity class 6 clouds from the Lynds Catalog of Dark Nebulae have been measured on blue and red prints from the Polomar Observatory Sky Survey (POSS) plates. These revised positions and the dimensions of ellipses fitted to the clouds are listed. The IRAS point source catalog has been searched for sources lying within the boundaries of the 147 clouds in the sample. The distribution and properties of these IRAS sources are discussed briefly. (author)

  9. Effect of cigarette smoking on the detection of small radiographic opacities in inorganic dust diseases

    International Nuclear Information System (INIS)

    Blanc, P.D.; Gamsu, G.

    1988-01-01

    Whether cigarette smoking can cause radiographic opacities indistinguishable from those due to pneumoconiosis remains controversial. The situation becomes clearer when one limits the abnormalities to those that can be standardized under the International Labour Office (ILO) classification system. The bulk of the evidence indicates that, using the ILO system, cigarette smoking alone is not associated with radiographic opacities that would be mistaken for pneumoconiosis with sufficient frequency to be of any practical importance. The effects of cigarette smoking, as a cofactor, in conjunction with occupational dust exposure depend on the type of dust. No relationship has been convincingly demonstrated for coal dust or silica. Only with asbestos exposure does there appear to be a significant cigarette smoking-associated increase in the frequency of irregular radiographic opacities. This increase does not appear to translate into a restrictive impairment in pulmonary function. The limited information available indicates that the features of asbestosis on high-resolution computed tomography are not similarly related to cigarette smoking. Additional research is needed to substantiate the relationship between smoking and occupational exposure to dust of many types, and also the possible imaging and pathophysiologic significance of their interactions. 47 references

  10. Irreducible Traumatic Posterior Shoulder Dislocation

    Directory of Open Access Journals (Sweden)

    Blake Collier

    2017-01-01

    Full Text Available History of present illness: A 22-year-old male presented to the Emergency Department complaining of right shoulder pain after a motocross accident. He was traveling at approximately 10 mph around a turn when he lost control and was thrown over the handlebars, landing directly on his right shoulder. On arrival, he was holding his arm in adduction and internal rotation. An area of swelling was noted over his anterior shoulder. He was unable to abduct his shoulder. No humeral gapping was noted. He had normal neuro-vascular status distal to the injury. Significant findings: Radiographs demonstrated posterior displacement of the humeral head on the “Y” view (see white arrow and widening of the glenohumeral joint space on anterior-posterior view (see red arrow. The findings were consistent with posterior dislocation and a Hill-Sachs type deformity. Sedation was performed and reduction was attempted using external rotation, traction counter-traction. An immediate “pop” was felt during the procedure. Post-procedure radiographs revealed a persistent posterior subluxation with interlocking at posterior glenoid. CT revealed posterior dislocation with acute depressed impaction deformity medial to the biceps groove with the humeral head perched on the posterior glenoid, interlocked at reverse Hill-Sachs deformity (see blue arrow. Discussion: Posterior shoulder dislocations are rare and represent only 2% of all shoulder dislocations. Posterior shoulder dislocations are missed on initial diagnosis in more than 60% of cases.1 Posterior shoulder dislocations result from axial loading of the adducted and internally rotated shoulder, violent muscle contractions (resulting from seizures or electrocution, a direct posterior force applied to the anterior shoulder.1 Physical findings include decreased anterior prominence of the humeral head, increased palpable posterior prominence of the humeral head below the acromion, increased palpable prominence of the

  11. A clickstream data analysis of Chinese academic library OPAC users' information behavior

    NARCIS (Netherlands)

    Jiang, Tingting; Chi, Yu; Gao, Huiqin

    2017-01-01

    Chinese academic libraries have been devoting great effort into introducing next-generation online public access catalogs (OPACs) in order to provide a better user experience. However, there is a lack of empirical research on their usage. In this study, a transaction log file from a typical

  12. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    Science.gov (United States)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  13. Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction.

    Science.gov (United States)

    Kramer, Gregory D; Werner, Liliana; Neuhann, Tobias; Tetz, Manfred; Mamalis, Nick

    2015-09-01

    We describe the case of a patient who had cataract surgery with implantation of the hydrophilic acrylic Tetraflex accommodating intraocular lens (IOL), with subsequent development of capsulorhexis phimosis and in-the-bag IOL subluxation. Contraction of the capsular bag secondary to fibrosis resulted in significant anterior flexing of the lens haptic component. Explantation of the IOL-capsular bag complex was required 7 years after implantation. Histopathologic analysis demonstrated multiple areas of thick anterior subcapsular fibrosis. Pseudoexfoliative material was present throughout the surface of the lens capsule. Intraocular lenses manufactured from hydrophilic acrylic material are highly flexible and may be more susceptible to capsule contraction, even in the absence of predisposing ocular and systemic conditions. This case highlights the importance of developing guidelines regarding patient screening and selection for the appropriate use of accommodating and other highly flexible IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Arab Libraries’ Web-based OPACs: An evaluative study in the light of IFLA’s Guidelines For Online Public Access Catalogue (OPAC Displays

    Directory of Open Access Journals (Sweden)

    Sherif Kamel Shaheen

    2005-03-01

    Full Text Available The research aims at evaluating Arabic Libraries’ Web-based Catalogues in the light of Principles and Recommendations published in: IFLA’s Guidelines For OPAC Displays (September 30, 2003 Draft For Worldwide Review. The total No. Of Recommendations reached” 38 “were categorized under three main titles, as follows: User Needs (12 recommendations, Content and arrangement Principle (25 recommendations, Standardization Principle (one recommendation However that number increased to reach 88 elements when formulated as evaluative criteria and included in the study’s checklist.

  15. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    Science.gov (United States)

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  16. Open inferior capsular shift for multidirectional shoulder instability in adolescents with generalized ligamentous hyperlaxity or Ehlers-Danlos syndrome.

    Science.gov (United States)

    Vavken, Patrick; Tepolt, Frances A; Kocher, Mininder S

    2016-06-01

    The objective of this study was to assess the outcome of open inferior capsular shift for multidirectional shoulder instability in patients with generalized ligamentous hyperlaxity or Ehlers-Danlos syndrome. Data were obtained for 18 open inferior capsular shift surgeries in 15 adolescent patients with generalized ligamentous hyperlaxity or Ehlers-Danlos syndrome with a mean follow-up of 7.5 years. End points were subjective clinical outcome (pain, stability, satisfaction, return to sport), objective clinical outcome (recurrence, complications), and functional outcome scores (American Shoulder and Elbow Surgeons, 11-item version of the Disabilities of Arm, Shoulder and Hand). Thirteen patients (87%) reported improved pain and stability and were satisfied with the procedure. Nine patients (64%) were able to return to sports. One patient (7%) was dissatisfied with continuous pain and recurrent instability and considered a surgical failure. Seven patients (47%) reported no further episodes of instability. The mean American Shoulder and Elbow Surgeons score at a mean of 7.5 years of follow-up was 88 ± 10 points, and the mean score for the 11-item version of the Disabilities of Arm, Shoulder and Hand was 14 ± 14 points. The management of multidirectional shoulder instability in adolescent patients with generalized ligamentous hyperlaxity or Ehlers-Danlos syndrome is challenging. Open inferior capsular shift results in improvement in subjective and objective shoulder function and stability in adolescent patients with ligamentous hyperlaxity or Ehlers-Danlos who have failed nonoperative treatment. We found no effect of the recalled number of prior dislocations, laterality, and type of hyperlaxity on subjective and objective clinical outcomes. Level IV; Case Series; Treatment Study. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. A structural study of the capsular antigens of Escherichia coli K36 and Klebsiella K68

    International Nuclear Information System (INIS)

    Stanley, S.M.R.

    1986-01-01

    This thesis discusses the structural study of the capsular antigens of the bacteria, Escherichia coli K36 and Klebsiella K68. In the elucidation of bacterial polysaccharides chemically based analytical procedures and instrumental analytical techniques were used. Nuclear magnetic resonance is a powerful tool for obtaining structural information on poly-, oligo- and di-saccharides and a detailed discussion of this technique, and the results obtained in this study, is given

  18. Development of an Aerosol Opacity Retrieval Algorithm for Use with Multi-Angle Land Surface Images

    Science.gov (United States)

    Diner, D.; Paradise, S.; Martonchik, J.

    1994-01-01

    In 1998, the Multi-angle Imaging SpectroRadiometer (MISR) will fly aboard the EOS-AM1 spacecraft. MISR will enable unique methods for retrieving the properties of atmospheric aerosols, by providing global imagery of the Earth at nine viewing angles in four visible and near-IR spectral bands. As part of the MISR algorithm development, theoretical methods of analyzing multi-angle, multi-spectral data are being tested using images acquired by the airborne Advanced Solid-State Array Spectroradiometer (ASAS). In this paper we derive a method to be used over land surfaces for retrieving the change in opacity between spectral bands, which can then be used in conjunction with an aerosol model to derive a bound on absolute opacity.

  19. TIPTOPbase: the Iron Project and the Opacity Project Atomic Database

    Science.gov (United States)

    Mendoza, Claudio; Nahar, Sultana; Pradhan, Anil; Seaton, Micheal; Zeippen, Claude

    2001-05-01

    The Opacity Project, the IRON Project, and the RmaX Network (The Opacity Project Team, Vol.1,2), IOPP, Bristol (1995,1996); Hummer et al., Astron. Astrophys. 279, 298 (1993) are international computational efforts concerned with the production of high quality atomic data for astrophysical applications. Research groups from Canada, France, Germany, UK, USA and Venezuela are involved. Extensive data sets containing accurate energy levels, f-values, A-values, photoionisation cross sections, collision strengths, recombination rates, and opacitites have been computed for cosmically abundant elements using state-of-the-art atomic physics codes. Their volume, completeness and overall accuracy are presently unmatched in the field of laboratory astrophysics. Some of the data sets have been available since 1993 from a public on-line database service referred to as TOPbase (Cunto et al Astron. Astrophys. 275), L5 (1993), ( http://cdsweb.u-strasbg.fr/OP.html at CDS France, and http://heasarc.gsfc.nasa.gov/topbase, at NSAS USA). We are currently involved in a major effort to scale the existing database services to develop a robust platform for the high-profile dissemination of atomic data to the scientific community within the next 12 months. (Partial support from the NSF and NASA is acknowledged.)

  20. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    Science.gov (United States)

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Results: Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16–0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: −1.32, 95% CI = −2.39 to −0.25, P = .015) and estimated PCO score (diff. in means: −2.23; 95% CI, −3.80 to −0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: −0.075; 95% CI, −0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: −0.016; 95% CI, −0.041 to 0.009, P = .208). Conclusion: In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity. PMID:29095259

  1. Classification of posterior vitreous detachment

    Science.gov (United States)

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2014-01-01

    Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography (OCT). By biomicroscopy, the vitreous condition is determined based on the presence or absence of a PVD. The PVD then is classified as either a complete posterior vitreous detachment (C-PVD) or a partial posterior vitreous detachment (P-PVD). A C-PVD is further divided into a C-PVD with collapse and a C-PVD without collapse, while a P-PVD is divided into a P-PVD with shrinkage of the posterior hyaloid membrane (P-PVD with shrinkage) and a P-PVD without shrinkage of the posterior hyaloid membrane (P-PVD without shrinkage). A P-PVD without shrinkage has a subtype characterized by vitreous gel attachment through the premacular hole in a posterior hyaloid membrane to the macula (P-PVD without shrinkage [M]). By OCT, a shallow PVD is classified as the absence of a shallow PVD or as a shallow PVD. A shallow PVD is then subclassified as a shallow PVD without shrinkage of the posterior vitreous cortex, a shallow PVD with shrinkage of the posterior vitreous cortex, and a peripheral shallow PVD. A shallow PVD without shrinkage of the posterior vitreous cortex has two subtypes: an age-related shallow PVD and a perifoveal PVD associated with a macular hole. PMID:24376338

  2. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  3. Design for LTE EOS and opacity experiments using supersonic radiation waves

    Science.gov (United States)

    Tierney, T. E.; Peterson, R. R.; Tierney, H. E.

    2007-11-01

    Opacity and EOS at 100-200 eV are important physical parameters in ICF experiments. We describe an experiment design that uses the supersonic propagation of hohlraum radiation in foams to isochorically heat samples. Laser and Z-pinch experiments frequently use 150 to 220-eV quasi-blackbody emission from hohlraums to drive physics experiments. A foam target encapsulated in a gold-wall cylinder is placed next to the hohlraum. The low density and opacity foam captures some hohlraum emission and generates a supersonically-propagating radiation wave. The material heated by the wave is cooler towards the high-albedo gold wall. Modeling and past measurements show that core regions of the foam have small thermal gradients. We place a small, thin sample (e.g., Al, Si, or Fe) in the thermally-uniform region. X-ray emission of tracers and the sample as well as quasi-continuum x-ray absorption will be measured using time-resolved x-ray spectroscopy. The foam's EOS can be measured to ±5% by blast waves with a well characterized drive. This experiment could use the OMEGA, Z-Beamlet, and/or ZR facilities to explore temperature-dependent conditions.

  4. Biodegradable X-ray markers of controlled radio-opacity. Temporary position measurements in bone

    NARCIS (Netherlands)

    Stallmann, H.P.; Faber, C.; Plokker, H.M.; Wuisman, P.I.J.M.

    2005-01-01

    In order to analyze X-ray markers for potential use in biodegradable implants or radiostereogrammatic analysis (RSA), we combined iopromide contrast fluid with biodegradable calcium phosphate cement. The radio-opacity of 10 × 10 mm markers containing different iodine concentrations (0,120, 240, 360

  5. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  6. Late-onset Alzheimer disease genetic variants in posterior cortical atrophy and posterior AD.

    Science.gov (United States)

    Carrasquillo, Minerva M; Khan, Qurat ul Ain; Murray, Melissa E; Krishnan, Siddharth; Aakre, Jeremiah; Pankratz, V Shane; Nguyen, Thuy; Ma, Li; Bisceglio, Gina; Petersen, Ronald C; Younkin, Steven G; Dickson, Dennis W; Boeve, Bradley F; Graff-Radford, Neill R; Ertekin-Taner, Nilüfer

    2014-04-22

    To investigate association of genetic risk factors for late-onset Alzheimer disease (LOAD) with risk of posterior cortical atrophy (PCA), a syndrome of visual impairment with predominant Alzheimer disease (AD) pathology in posterior cortical regions, and with risk of "posterior AD" neuropathology. We assessed 81 participants with PCA diagnosed clinically and 54 with neuropathologic diagnosis of posterior AD vs 2,523 controls for association with 11 significant single nucleotide polymorphisms (SNPs) from published LOAD risk genome-wide association studies. There was highly significant association with APOE ε4 and increased risk of PCA (p = 0.0003, odds ratio [OR] = 3.17) and posterior AD (p = 1.11 × 10(-17), OR = 6.43). No other locus was significant after corrections for multiple testing, although rs11136000 near CLU (p = 0.019, OR = 0.60) and rs744373 near BIN1 (p = 0.025, OR = 1. 63) associated nominally significantly with posterior AD, and rs3851179 at the PICALM locus had significant association with PCA (p = 0.0003, OR = 2.84). ABCA7 locus SNP rs3764650, which was also tested under the recessive model because of Hardy-Weinberg disequilibrium, also had nominally significant association with PCA risk. The direction of association at APOE, CLU, and BIN1 loci was the same for participants with PCA and posterior AD. The effects for all SNPs, except rs3851179, were consistent with those for LOAD risk. We identified a significant effect for APOE and nominate CLU, BIN1, and ABCA7 as additional risk loci for PCA and posterior AD. Our findings suggest that at least some of the genetic risk factors for LOAD are shared with these atypical conditions and provide effect-size estimates for their future genetic studies.

  7. Lenticular opacities in proximally exposed A-bomb survivors and their lately significance

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Ophthalmological Clinic, Hiroshima (Japan)

    1978-04-01

    Five cases of lenticular opacities in proximally exposed A-bomb survivors (not published yet) were reported with some slides. From these experiment cases, following items were investigated. Significance of A-bomb radiation cataracts: Because cataract is the first manifistation of delayed hazard to a human body caused by A-bomb radiation and can be observed still now, cataract is regarded to be very important for recognizing A-bomb hazard. The manifestation of these findings of cataract is the reason for strong appeals that A-bomb hazard is still existing. Clinical findings of lenticular opacities was searched with reference to the literature. Several findings in experiment cases were described, and the importance of the study about changes of clinical findings was mentioned. It was pointed out that radiation cataract is closely related to the loss of hair in acute atomic radiation hazard. In case of radiation cataract, some difference between right and left eye was sometimes observed. Studies concerning this difference should be further developed in future. The importance of the factors of shielding was pointed out.

  8. International comparative evaluation of fixed-bearing non-posterior-stabilized and posterior-stabilized total knee replacements.

    Science.gov (United States)

    Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen

    2014-12-17

    Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero

  9. Improvement of chronic corneal opacity in ocular surface disease with prosthetic replacement of the ocular surface ecosystem (PROSE) treatment.

    Science.gov (United States)

    Cressey, Anna; Jacobs, Deborah S; Remington, Crystal; Carrasquillo, Karen G

    2018-06-01

    To demonstrate clearing of chronic corneal opacities and improvement of visual acuity with the use of BostonSight prosthetic replacement of the ocular surface ecosystem (PROSE) treatment in ocular surface disease. We undertook retrospective analysis of the medical records of a series of patients who underwent PROSE treatment from August 2006 to December 2014. Patients were referred for ocular surface disease of various etiologies. Primary inclusion criterion was corneal opacity that improved with PROSE treatment. Patients were excluded if topical steroids or adjuvant therapy used once PROSE treatment was initiated. Underlying disease, prior treatment, clinical presentation, and clinical course were extracted from the medical record. Four patients are included in this series. There were three females and one male; median age at time of treatment initiation was 30 years (range = 0.5-58 years). Median duration of PROSE treatment at time of retrospective analysis was 3.5 years (range = 1-8 years). Two cases had corneal opacification in the context of neurotrophic keratopathy: a unilateral case due to presumed herpes simplex keratitis and a bilateral case due to congenital corneal anesthesia associated with familial dysautonomia. One case had corneal opacity from exposure related to seventh nerve palsy, and one had corneal opacification associated with recurrent surface breakdown, neurotrophic keratopathy, and limbal stem deficiency of uncertain etiology. After consistent wear of prosthetic devices used in PROSE treatment for support of the ocular surface, visual acuity improved and clearing of the opacities was observed, without use of topical steroids or adjuvant therapy. These cases demonstrate clearing of chronic corneal opacity with PROSE treatment for ocular surface disease. This clearing can occur with no adjuvant therapy, suggesting that restoration of ocular surface function and integrity allows for corneal remodeling.

  10. An OMV Vaccine Derived from a Capsular Group B Meningococcus with Constitutive FetA Expression: Preclinical Evaluation of Immunogenicity and Toxicity.

    Directory of Open Access Journals (Sweden)

    Gunnstein Norheim

    Full Text Available Following the introduction of effective protein-polysaccharide conjugate vaccines against capsular group C meningococcal disease in Europe, meningococci of capsular group B remain a major cause of death and can result in debilitating sequelae. The outer membrane proteins PorA and FetA have previously been shown to induce bactericidal antibodies in humans. Despite considerable antigenic variation among PorA and FetA OMPs in meningococci, systematic molecular epidemiological studies revealed this variation is highly structured so that a limited repertoire of antigenic types is congruent with the hyperinvasive meningococcal lineages that have caused most of the meningococcal disease in Europe in recent decades. Here we describe the development of a prototype vaccine against capsular group B meningococcal infection based on a N. meningitidis isolate genetically engineered to have constitutive expression of the outer membrane protein FetA. Deoxycholate outer membrane vesicles (dOMVs extracted from cells cultivated in modified Frantz medium contained 21.8% PorA protein, 7.7% FetA protein and 0.03 μg LPS per μg protein (3%. The antibody response to the vaccine was tested in three mouse strains and the toxicological profile of the vaccine was tested in New Zealand white rabbits. Administration of the vaccine, MenPF-1, when given by intramuscular injection on 4 occasions over a 9 week period, was well tolerated in rabbits up to 50 μg/dose, with no evidence of systemic toxicity. These data indicated that the MenPF-1 vaccine had a toxicological profile suitable for testing in a phase I clinical trial.

  11. Conceptual design of initial opacity experiments on the national ignition facility

    Energy Technology Data Exchange (ETDEWEB)

    Heeter, R.  F.; Bailey, J.  E.; Craxton, R.  S.; DeVolder, B.  G.; Dodd, E.  S.; Garcia, E.  M.; Huffman, E.  J.; Iglesias, C.  A.; King, J.  A.; Kline, J.  L.; Liedahl, D.  A.; McKenty, P.  W.; Opachich, Y.  P.; Rochau, G.  A.; Ross, P.  W.; Schneider, M.  B.; Sherrill, M.  E.; Wilson, B.  G.; Zhang, R.; Perry, T.  S.

    2017-01-09

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative–convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures${\\geqslant}150$ eV and electron densities${\\geqslant}7\\times 10^{21}~\\text{cm}^{-3}$. The iron will be probed using continuum X-rays emitted in a${\\sim}200$ ps,${\\sim}200~\\unicode[STIX]{x03BC}\\text{m}$diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design

  12. MR imaging of the combined anterior and posterior cruciate ligament tears: focussing on the ratterns of injuries and associated findings

    International Nuclear Information System (INIS)

    Kwon, Seon Young; Choi, Chang Lak; Park, Dal Soo; Park, Eun Hee; Lee, Sang Ho; Song, Mun Kab; Lee, Kwang Won; Kwon, Soon Tae

    1997-01-01

    To evaluate the patterns of injuries and frequency of associated findings on MR imaging in patients with both anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL)tears;to compare the associated findings, as seen on MR imaging, in cases with both ACL and PCL tears with those with ACL or PCL tears. Ten patients with compbined ACL and PCL tears, 16 with ACL tears and 18 with PCL tears, all confirmed by arthroscopy or open surgery, were involved in this study. To identify the associated knee injuries, MR images were retrospectively evaluated. In ten patients with combined ACL and PCL tears, open surgery led to the identification of six complete ACL tears (60%), four partial ACL tears (40%), eitht complete PCL tears (80%) and two partial PCL tears (20%). Injuries associated with these combined tears, and revealed by MR imaging, comprised six medial collateral ligament injuries (60%), six lateral collateral ligament jnjuries (60%), five medial meniscal injuries (50%), three lateral meniscal injuries (30%), nine bony injuries (90%), two posterior capsular injuries (20%), and three popliteus muscle injuries (30%). The frequency of popliteus muscle injury was significantly different (p<0.05, Fisher's exact test) between the group with both ACL and PCL tears and that with ACL or PCL tears. Associated findings in patients with combined ACL and PCL tears are more frequent than in those with ACL or PCL tears. In cases involving combined ACL and PCL tears, associated findings-as seen on MR images-should thus be carefully examined

  13. Influence of the number of atomic levels on the spectral opacity of low temperature nickel and iron in the spectral range 50-300 eV

    International Nuclear Information System (INIS)

    Busquet, M.; Klapisch, M.; Gilles, D.

    2013-01-01

    Opacity is a fundamental ingredient for the secular evolution of stars. The calculation of the stellar plasma absorption coefficients is complex due to the composition of these plasmas, generally an H /He dominated mixture with a low concentration of partially ionized heavy ions (the iron group). The international collaboration OPAC recently presented extensive comparisons of spectral opacities of iron and nickel for temperatures between 15 and 40 eV and for densities of ∼ 3 mg/cm 3 , relevant to the stellar envelope conditions [1, 2]. The role of Configuration Interaction (CI) and the influence of the number of atomic levels on the opacity using the recently improved version of HULLAC atomic code [3, 4] are illustrated in this article. Comparisons with theoretical predictions already presented in [1] are discussed. (authors)

  14. APLIKASI ONLINE PUBLIC ACCESS CATALOQUE (OPAC BERBASIS ANDROID SEBAGAI SARANA TEMU KEMBALI INFORMASI DI PERPUSTAKAAN UNIVERSITAS PENDIDIKAN GANESHA

    Directory of Open Access Journals (Sweden)

    Putu Tika Parmawati

    2016-08-01

    Full Text Available Abstrak Penelitian ini bertujuan untuk mengembangkan perangkat lunak aplikasi Online Public Access Cataloque (OPAC berbasis android. Jenis penelitian ini merupakan Research and Development (R & D dengan metode pengembangan menggunakan model prototyping. Pengembangan sistem informasi layanan audio visual berbasis video streaming dengan enam tahap, yaitu : 1 Tahap pengumpulan kebutuhan dan perbaikan, 2 Tahap perancangan desain cepat (desain awal, 3 Tahap membangun prototipe, 4 Tahap evaluasi prototype, 5 Tahap perbaikan prototype, dan 6 Tahap rekayasa produk. Penentuan tingkat kelayakan aplikasi Online Public Access Cataloque (OPAC berbasis android berdasarkan uji validasi ahli bidang teknologi informasi dan uji coba terbatas pada pengguna. Hasil uji coba sebagai berikut : 1 Pengembangan aplikasi Online Public Access Cataloque (OPAC berbasis android sudah sesuai dengan spesifikasi yang telah ditentukan sebagai aplikasi penelusuran informasi koleksi buku teks umum secara online melalui smartphone. 2 Indikator penilaian dari program ini adalah kebenaran atau ketepatan operasional sistem, ketegaran, keterluasan, keterpakaian ulang, efisiensi atau kinerja, portabilitas, integritas, modularitas, keterbacaan mendapat kualifikasi cukup baik, sedangkan verifikasi mendapat kualifikasi baik. 3 Secara umum dari hasil penilaian tersebut aplikasi OPAC berbasis android ini cukup layak untuk digunakan sebagai alternatif pelengkap pemberian layanan penelusuran informasi koleksi buku teks umum di Perpustakaan Undiksha. Kata Kunci: OPAC, android, dan temu kembali informasi Abstract Aim of this study to develop the software of Online Public Access Cataloque (OPAC based on android. Research and Development (R & D design was applied in this study which was developed through prototyping models. The software was constructed through six stages, namely: 1 needs analysis and repairment, 2 rapid design (preliminary design, 3 prototypes building, 4 prototype evaluation, 5

  15. The Rosseland Mean Opacity in Dense Plasmas

    Science.gov (United States)

    van Horn, H. M.

    1992-05-01

    In post-main-sequence phases of stellar evolution, densities in the interiors of stars become large enough so that hbar omega_p /kT>1, where omega_p is the electron plasma frequency. The plasma is thus a strongly dispersive medium at frequencies near the peak of the Planck function, and only photons with frequencies omega >omega_p can propagate in the plasma. These effects must be taken into account in computing radiative transfer in stellar interiors. Here I first identify several late evolutionary stages in which these effects may be significant. Then I use the formalism Harris 1965 has developed to treat radiative transfer in a dispersive medium in order to derive the resulting modification of the Rosseland mean opacity kappa_R . The resulting expression is the same as that presented (without a full derivation) by Aharony & Opher 1979, who interpreted the frequency-dependent absorption coefficient kappa_ ω as that in vacuo. However, the absorption coefficient in a plasma scales from that in vacuum according to the relation kappa_ ω=n_ω(-1) kappa_ ω((vac)) (Bekefi 1966, p. 52), where n_ω equiv (kc/omega ) = [1-(omega_p (2/) omega (2)right ](1/2)) is the index of refraction of the plasma. With this correction, we find the Rosseland mean opacity to be given by the expression {1\\over \\kappa_R}={{\\int_{\\omega_p}^{\\infty} {n_{\\omega}^3 \\over \\kappa_{\\omega}^{(vac)}}{partial B_{\\omega} \\over partial T} \\bigg|_{\\omega} d\\omega} \\over{\\int_0^{\\infty}{partial B_{\\omega} \\over partial T} \\bigg|_{\\omega} d\\omega}}. This research has been supported in part by NASA grant NAGW-2444 and in part by NSF grant AST 91-15132. \\centerline{References} Aharony, U., and Opher, R. 1979, A&A, 79, 27. Bekefi, G. 1966, Radiation Processes in Plasmas, (John Wiley & Sons, Inc.: New York). Harris, E. G. 1965, Phys. Rev., 138, B479.

  16. Opacity broadening and interpretation of suprathermal CO linewidths: Macroscopic turbulence and tangled molecular clouds

    Science.gov (United States)

    Hacar, A.; Alves, J.; Burkert, A.; Goldsmith, P.

    2016-06-01

    Context. Since their first detection in the interestellar medium, (sub-)millimeter line observations of different CO isotopic variants have routinely been employed to characterize the kinematic properties of the gas in molecular clouds. Many of these lines exhibit broad linewidths that greatly exceed the thermal broadening expected for the low temperatures found within these objects. These observed suprathermal CO linewidths are assumed to originate from unresolved supersonic motions inside clouds. Aims: The lowest rotational J transitions of some of the most abundant CO isotopologues, 12CO and 13CO, are found to present large optical depths. In addition to well-known line saturation effects, these large opacities present a non-negligible contribution to their observed linewidths. Typically overlooked in the literature, in this paper we aim to quantify the impact of these opacity broadening effects on the current interpretation of the CO suprathermal line profiles. Methods: Combining large-scale observations and LTE modeling of the ground J = 1-0 transitions of the main 12CO, 13CO, C18O isotopologues, we have investigated the correlation of the observed linewidths as a function of the line opacity in different regions of the Taurus molecular cloud. Results: Without any additional contributions to the gas velocity field, a large fraction of the apparently supersonic (ℳ ~ 2-3) linewidths measured in both 12CO and 13CO (J = 1-0) lines can be explained by the saturation of their corresponding sonic-like, optically thin C18O counterparts assuming standard isotopic fractionation. Combined with the presence of multiple components detected in some of our C18O spectra, these opacity effects also seem to be responsible for most of the highly supersonic linewidths (ℳ > 8-10) detected in some of the broadest 12CO and 13CO spectra in Taurus. Conclusions: Our results demonstrate that most of the suprathermal 12CO and 13CO linewidths reported in nearby clouds like Taurus

  17. Radiation-induced eye lens changes and risk for cataract in interventional cardiology.

    Science.gov (United States)

    Ciraj-Bjelac, O; Rehani, M; Minamoto, A; Sim, K H; Liew, H B; Vano, E

    2012-01-01

    Recent studies have reported a significant increase in eye lens opacities among staff in the cardiac catheterization laboratory but indicated further studies are needed to confirm the findings. To evaluate the prevalence of opacities in eyes of cardiologists, radiographers and nurses working in interventional cardiology. The eyes of 52 staff in interventional cardiology facilities and 34 age- and sex-matched unexposed controls were screened in a cardiology conference held in Kuala Lumpur by dilated slit-lamp examination, and posterior lens changes were graded. Individual cumulative lens X-ray exposures were calculated from responses to a questionnaire in terms of workload and working practice. The prevalence of posterior lens opacities among interventional cardiologists was 53%, while in nurses and radiographers it was 45%. Corresponding relative risks were 2.6 (95% CI: 1.2-5.4) and 2.2 (95% CI: 0.98-4.9), for interventional cardiologists and support staff, respectively. This study confirms a statistically significant increase in radiation-associated posterior lens changes in the eyes of interventional cardiology staff. Copyright © 2012 S. Karger AG, Basel.

  18. Surgery for Pulmonary Multiple Ground Glass Opacities

    Directory of Open Access Journals (Sweden)

    Qun WANG

    2016-06-01

    Full Text Available The incidence of pulmonary ground glass opacity (GGO has been increasing in recent years, with a great number of patients having multiple GGOs. Unfortunately, the management of multiple GGOs is still controversial. Pulmonary GGO is a radiological term, consisting of different pathological types. Some of the GGOs are early-staged lung cancer. GGO is an indolent nodule, only a small proportion of GGOs change during observation, which does not influence the efficacy of surgery. . The timing of surgery for multiple GGOs mainly depends on the predominant nodule and surgery is recommended if the solid component of the predominant nodule >5 mm. Either lobectomy or sub-lobectomy is feasible. GGOs other than the predominant nodule can be left unresected. Multiple GGOs with high risk factors need mediastinal lymph node dissection or sampling.

  19. CLINICAL OUTCOME OF PENETRATING KERATOPLASTY IN CORNEAL OPACITIES OF DIFFERENT AETIOLOGY- A CLINICAL STUDY

    Directory of Open Access Journals (Sweden)

    Dipak Bhuyan

    2017-01-01

    Full Text Available BACKGROUND Corneal transplantation or grafting is an operation in which abnormal corneal host tissue is replaced by healthy donor cornea. According to the World Health Organization (WHO, corneal diseases are among the major causes of vision loss and blindness in the world today after cataract and glaucoma. The aim of the study is to- 1. Evaluate the different aetiology of corneal opacity including active infective aetiology as indicated for penetrating keratoplasty. 2. Determine the clinical outcome of penetrating keratoplasty in relation to graft survival, graft rejection and peri-operative complications in different aetiology groups. 3. Determine the final visual outcome. MATERIALS AND METHODS Candidates for keratoplasty were selected from- 1. Eye Bank of Regional Institute of Ophthalmology (R.I.O. 2. R.I.O OPD. The study period was from September 2014 to August 2015. 30 cases were taken in the study. Descriptive statistics were applied to analyse the data wherever necessary. RESULTS 34.6±19.73 yrs. (mean±SD was the mean age at which transplants were done in the study. Out of total 30 cases, 13 (43.33% and 17 (56.66% were male and female, respectively. The different indications for penetrating keratoplasty are- Post ulcer corneal opacity in 14 cases (46.66%, posttraumatic corneal opacity 9 cases (30%, pseudophakic bullous keratopathy 4 cases (13.33%, corneal dystrophy in 2 cases (6.66% and non-healing corneal ulcer in 1 case (3.33%. 16 cases (53.33% showed clear graft till the last follow up while 11 (33.33% cases showed partially clear graft resulting in improved visual outcome while 3 cases (10.00% of the grafts were opaque due to graft failure. CONCLUSION The major indications for penetrating keratoplasty in this part of the world are post ulcer and posttraumatic corneal opacity and majority of them are illiterate agricultural workers who failed to get adequate treatment on time. Graft survival rate is high, which can be attributed to the

  20. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  1. 77 FR 8160 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ... with the opacity measurement/reference beam(s), spectrally selective optical filters, beam splitters... Monitor Manufacturers to Certify Conformance with Design and Performance Specifications, whereas the 2003... my COMS? Necessary components of the routine system checks will depend on the design details of your...

  2. 'Seeing the Dark': Grounding Phenomenal Transparency and Opacity in Precision Estimation for Active Inference.

    Science.gov (United States)

    Limanowski, Jakub; Friston, Karl

    2018-01-01

    One of the central claims of the Self-model Theory of Subjectivity is that the experience of being someone - even in a minimal form - arises through a transparent phenomenal self-model, which itself can in principle be reduced to brain processes. Here, we consider whether it is possible to distinguish between phenomenally transparent and opaque states in terms of active inference. We propose a relationship of phenomenal opacity to expected uncertainty or precision; i.e., the capacity for introspective attention and implicit mental action. Thus we associate introspective attention with the deployment of 'precision' that may render the perceptual evidence (for action) opaque, while treating transparency as a necessary aspect of beliefs about action, i.e., 'what I am' doing. We conclude by proposing how we may have to nuance our conception of minimal phenomenal selfhood and agency in light of this active inference conception of transparency-opacity.

  3. Cataract surgery in patients with ocular pseudoexpholiation.

    Science.gov (United States)

    Petrovic, Mirjana Janicijevic; Vulovic, Tatjana Sarenac; Vulovic, Dejan; Janicijevic, Katarina; Petrovic, Marko; Vujic, Dragan

    2013-01-01

    Retrospective 5-year study based on general and ophthalmic history records, and including 268 eyes (174 patients), aged 50 years and over. Ophthalmological examination involved visual acuity, measuring of intraocular pressure, slit lamp examination and indirect ophthalmoscopy. Type of surgical treatment was tailored for each patient (extra capsular cataract extraction, phaco-emulsiphication). Preoperative slit lamp examination showed phacodonesis in 17.91% (47), iridodonesis in 2.98% (8), pigment dispersion in 6.72% (18), lens subluxation in 4.85% (13) on the total. Extra capsular cataract extraction was performed in 36.94% (99) and phaco-emulsiphication in the others. Analysis of intra operative complications showed: posterior capsular rupture 17.91% (48), zonular dialysis or break 5.97% (16), lens subluxation 1.86% (5), intraocular bleeding 2.98% (8), vitreous loss 13.80% (37). Postoperative complications include: anterior chamber reaction 45.90% (123), intraocular lens tilt 15.67% (42), endothelial decompensation 21.64% (58), subluxation/luxation IOL 3.73% (10), secondary cataract 21.46% (58), pigment dispersion 37.68% (101), increased IOP 13.80% (37), residual lens matter 13.80% (37), hyphema 3.73% (10), posterior synechiae 6.72% (18), iris prolapsus 2.73% (8). Cataract surgery in PES will frequently encounter small pupils, shallow anterior chambers, posterior adhesions, weak zonular support, partial subluxation or complete dislocation of lens. Authors presented the best possible approach on PES and surgical methods for patients with cataract with special accent of possible surgical complications.

  4. Model of opacity and emissivity of non-equilibrium plasma

    International Nuclear Information System (INIS)

    Politov V Y

    2008-01-01

    In this work the model describing absorption and emission properties of the non-equilibrium plasma is presented. It is based on the kinetics equations for populations of the ground, singly and doubly excited states of multi-charged ions. After solving these equations, the states populations together with the spectroscopic data, supplied in the special database for a lot ionization stages, are used for building the spectral distributions of plasma opacity and emissivity in STA approximation. Results of kinetics simulation are performed for such important X-ray converter as gold, which is investigated intensively in ICF-experiments

  5. Surface-bound capsular polysaccharide of type Ia group B Streptococcus mediates C1 binding and activation of the classic complement pathway

    International Nuclear Information System (INIS)

    Levy, N.J.; Kasper, D.L.

    1986-01-01

    The role of surface-bound type Ia group B Streptococcus (GBS) capsular polysaccharide in anti-body-independent binding of C1 and activation of the classic component pathway was investigated. In a radiolabeled bacterial-polymorphonuclear leukocyte (PMN) association assay, a measure of bacterial opsonization, preincubation of 3 H-type Ia GBS with purified F(ab') 2 to the organism blocked the association of the bacteria with PMN', and the inhibitory effect was dose dependent. The specificity of F(ab') 2 blocking was shown after adsorption of F(ab') 2 with type Ia polysaccharide-sensitized erythrocytes. Polysaccharide-adsorbed F(ab') 2 had a 70% decrease in ability to block the association of bacteria with PMN. Neuraminidase digestion removed 80% of the terminal sialic acid residues from the native polysaccharide. These neuraminidase-digested organisms had a 72% decrease in binding and transfer of purified C1 compared with non-enzyme-treated organisms. Type Ia capsular polysaccharide bound to sheep erythrocytes promoted classic complement pathway-mediated hemolysis of the cells. The role of C1 inhibitor (INH) in modulation of C1 activation by the organisms was investigated. The possibility existed that the C1 INH could be bound by the bacteria, allowing C1 activation to occur in the fluid phase. The inhibitor was purified from human serum, and its activity was measured before and after incubation with type Ia GBS. The organisms had no effect on C1 INH activity. Thus surface-bound capsular polysacchardie of type Ia GBS mediates C1 binding and classic pathway activation, and this does not involve the C1 INH

  6. Crescentic and ring-shaped opacities. CT features in two cases of bronchiolitis obliterans organizing pneumonia (BOOP)

    International Nuclear Information System (INIS)

    Voloudaki, A.E.; Bouros, D.E.; Froudarakis, M.E.; Datseris, G.E.; Apostolaki, E.G.; Gourtsoyiannis, N.C.

    1996-01-01

    Two cases of idiopathic bronchilitis obliterans organizing pneumonia (BOOP) with unusual CT findings are presented. On CT both cases exhibited crescentic and ring-shaped opacities, surrounding areas of groundglass attenuation, and associated with a nodular pattern in one patient and airspace consolidations in the second patient. CT-pathologic correlation dislosed that the central areas of groundglass attenuation corresponded to alveolar septal inflammation, in contrast to the denser periphery where granulomatous tissue in peripheral airspaces predominated. In the broad spectrum of CT findings, BOOP can exhibit specific CT features with regard to the crescentic or ring-shaped opacities with a central groundglass attenuation area. Since these features have not been described in any other disease, they might be characteristic features for the diagnosis of BOOP. (orig.)

  7. Functions of some capsular polysaccharide biosynthetic genes in Klebsiella pneumoniae NTUH K-2044.

    Directory of Open Access Journals (Sweden)

    Jin-Yuan Ho

    Full Text Available The growing number of Klebsiella pneumoniae infections, commonly acquired in hospitals, has drawn great concern. It has been shown that the K1 and K2 capsular serotypes are the most detrimental strains, particularly to those with diabetes. The K1 cps (capsular polysaccharide locus in the NTUH-2044 strain of the pyogenic liver abscess (PLA K. pneumoniae has been identified recently, but little is known about the functions of the genes therein. Here we report characterization of a group of cps genes and their roles in the pathogenesis of K1 K. pneumoniae. By sequential gene deletion, the cps gene cluster was first re-delimited between genes galF and ugd, which serve as up- and down-stream ends, respectively. Eight gene products were characterized in vitro and in vivo to be involved in the syntheses of UDP-glucose, UDP-glucuronic acid and GDP-fucose building units. Twelve genes were identified as virulence factors based on the observation that their deletion mutants became avirulent or lost K1 antigenicity. Furthermore, deletion of kp3706, kp3709 or kp3712 (ΔwcaI, ΔwcaG or Δatf, respectively, which are all involved in fucose biosynthesis, led to a broad range of transcriptional suppression for 52 upstream genes. The genes suppressed include those coding for unknown regulatory membrane proteins and six multidrug efflux system proteins, as well as proteins required for the K1 CPS biosynthesis. In support of the suppression of multidrug efflux genes, we showed that these three mutants became more sensitive to antibiotics. Taken together, the results suggest that kp3706, kp3709 or kp3712 genes are strongly related to the pathogenesis of K. pneumoniae K1.

  8. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis.

    Science.gov (United States)

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-11-01

    Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16-0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI = -2.39 to -0.25, P = .015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P = .208). In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.

  9. Primary Pulmonary Mucosa-Associated Lymphoid Tissue Lymphoma with a Nodular Opacity: Report of a Case.

    Science.gov (United States)

    Yoshino, Naoyuki; Hirata, Tomomi; Takeuchi, Chie; Usuda, Jitsuo; Hosone, Masaru

    2017-01-01

    Herein, we describe our experience in treating a case of primary pulmonary mucosa-associated lymphoid tissue lymphoma detected as a nodular opacity. A 79-year-old man was referred to our hospital. Computed tomography showed a nodular opacity measuring 20 mm in diameter with regular margins in segment 5 of the right middle lobe of the lung. Although the bronchoscopic brush cytology result was class III, the patient was tentatively diagnosed with suspected mucosa-associated lymphoid tissue lymphoma. A thoracoscopic right middle lobectomy was performed. The pathological findings showed nodular proliferation of small to medium-sized, mature-appearing atypical lymphoid cells, lymphoepithelial lesions, and vague follicles suggesting follicular colonization in some areas. The patient was diagnosed with low-grade small B-cell lymphoma and mucosa-associated lymphoid tissue lymphoma. He has remained well to date, 23 months after surgery, without evidence of recurrence.

  10. Opacificación capsular posterior en lentes intraoculares hidrofílicos en comparación con lentes intraoculares hidrofóbicos usando imágenes de Scheimpflug

    Directory of Open Access Journals (Sweden)

    Arturo Olguin Manríquez

    2016-03-01

    Conclusiones: Los resultados de la función visual son comparables entre ambos lentes. La opacificación de la cápsula posterior se vio en menor proporción con el LIO Akreos MI60 cuando se midió por imágenes de Scheimpflug, debido probablemente al diseño del lente. No se demostraron correlación entre ambas pruebas.

  11. Structure of the neutral capsular polysaccharide of Acinetobacter baumannii NIPH146 that carries the KL37 capsule gene cluster.

    Science.gov (United States)

    Arbatsky, Nikolay P; Shneider, Mikhail M; Kenyon, Johanna J; Shashkov, Alexander S; Popova, Anastasiya V; Miroshnikov, Konstantin A; Volozhantsev, Nikolay V; Knirel, Yuriy A

    2015-09-02

    Capsular polysaccharide (CPS) was isolated from Acinetobacter baumannii NIPH146, and the following structure of branched pentasaccharide repeating unit was established by sugar analyses along with 1D and 2D NMR spectroscopy: In comparison to most other known capsular polysaccharides of A. baumannii, the CPS studied is neutral and lacks any specific monosaccharide component. The synthesis, assembly and export of this structure could be attributed to genes in a novel capsule biosynthesis gene cluster, designated KL37, which was found in the NIPH146 genome. The CPS of A. baumannii NIPH146 shares the α-d-Galp-(1→6)-β-d-Glcp-(1→3)-d-GalpNAc-(1→ trisaccharide fragment with the CPS units of several A. baumannii strains, including ATCC 17978 and LUH 5537 that carry the KL3 and KL22 gene clusters, respectively. KL37 contains two genes for glycosyltransferases that are related to two glycosyltransferase genes present in both KL3 and KL22, and the encoded proteins could be tentatively assigned to linkages between sugars in the CPS repeat. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Distrofia corneana policromática posterior Polychromatic posterior corneal dystrophy

    OpenAIRE

    Patrick Frensel de Moraes Tzelikis; Ulisses Roberto dos Santos; Marco Antônio Guarino Tanure; Fernando Cançado Trindade

    2007-01-01

    Os autores descrevem quatro raros casos de distrofia corneana policromática posterior, ainda não descrito na literatura nacional. Observam-se opacidades puntiformes, policromáticas, de tamanho uniforme, localização estromal profunda, distribuídas de limbo a limbo e que não interferem na acuidade visual. É apresentada uma revisão dos casos de distrofia pré-Descemet existentes na literatura.The authors describe four rare cases of polychromatic posterior corneal dystrophy, not describe in nation...

  13. Intraocular lenses and clinical treatment in paediatric cataract

    Directory of Open Access Journals (Sweden)

    Camila Ribeiro Koch Pena

    2015-06-01

    Full Text Available Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.

  14. The Column Density Distribution and Continuum Opacity of the Intergalactic and Circumgalactic Medium at Redshift langzrang = 2.4

    Science.gov (United States)

    Rudie, Gwen C.; Steidel, Charles C.; Shapley, Alice E.; Pettini, Max

    2013-06-01

    We present new high-precision measurements of the opacity of the intergalactic and circumgalactic medium (IGM; CGM) at langzrang = 2.4. Using Voigt profile fits to the full Lyα and Lyβ forests in 15 high-resolution high-S/N spectra of hyperluminous QSOs, we make the first statistically robust measurement of the frequency of absorbers with H I column densities 14 \\lesssim log (N_H\\,\\scriptsize{ I}/ {cm}^{-2}) \\lesssim 17.2. We also present the first measurements of the frequency distribution of H I absorbers in the volume surrounding high-z galaxies (the CGM, 300 pkpc), finding that the incidence of absorbers in the CGM is much higher than in the IGM. In agreement with Rudie et al., we find that there are fractionally more high-N H I absorbers than low-N H I absorbers in the CGM compared to the IGM, leading to a shallower power law fit to the CGM frequency distribution. We use these new measurements to calculate the total opacity of the IGM and CGM to hydrogen-ionizing photons, finding significantly higher opacity than most previous studies, especially from absorbers with log (N_H\\,\\scriptsize{ I}/ {cm}^{-2}) law parameterization of the frequency distribution with a break near N H I ≈1015 cm-2. We compute new estimates of the mean free path (λmfp) to hydrogen-ionizing photons at z em = 2.4, finding λmfp = 147 ± 15 Mpc when considering only IGM opacity. If instead, we consider photons emanating from a high-z star-forming galaxy and account for the local excess opacity due to the surrounding CGM of the galaxy itself, the mean free path is reduced to λmfp = 121 ± 15 Mpc. These λmfp measurements are smaller than recent estimates and should inform future studies of the metagalactic UV background and of ionizing sources at z ≈ 2-3. Based on data obtained at the W. M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space

  15. Formation of Planetary Populations I: Metallicity & Envelope Opacity Effects

    Science.gov (United States)

    Alessi, Matthew; Pudritz, Ralph E.

    2018-05-01

    We present a comprehensive body of simulations of the formation of exoplanetary populations that incorporate the role of planet traps in slowing planetary migration. The traps we include in our model are the water ice line, the disk heat transition, and the dead zone outer edge. We reduce our model parameter set to two physical parameters: the opacity of the accreting planetary atmospheres (κenv) and a measure of the efficiency of planetary accretion after gap opening (fmax). We perform planet population synthesis calculations based on the initial observed distributions of host star and disk properties - their disk masses, lifetimes, and stellar metallicities. We find the frequency of giant planet formation scales with disk metallicity, in agreement with the observed Jovian planet frequency-metallicity relation. We consider both X-ray and cosmic ray disk ionization models, whose differing ionization rates lead to different dead zone trap locations. In both cases, Jovian planets form in our model out to 2-3 AU, with a distribution at smaller radii dependent on the disk ionization source and the setting of envelope opacity. We find that low values of κenv (0.001-0.002 cm2 g-1) and X-ray disk ionization are necessary to obtain a separation between hot Jupiters near 0.1 AU, and warm Jupiters outside 0.6 AU, a feature present in the data. Our model also produces a large number of super Earths, but the majority are outside of 2 AU. As our model assumes a constant dust to gas ratio, we suggest that radial dust evolution must be taken into account to reproduce the observed super Earth population.

  16. Important consequences of atomic diffusion inside main-sequence stars: opacities, extra-mixing, oscillations

    Directory of Open Access Journals (Sweden)

    Deal M.

    2017-01-01

    Full Text Available Atomic diffusion, including the effects of radiative accelerations on individual elements, leads to important variations of the chemical composition inside stars. The accumulation of important elements in specific layers leads to a local increase of the average opacity and to hydrodynamic instabilities that modify the internal stellar structure. This can also have important consequences for asteroseismology.

  17. On the necessity of composition-dependent low-temperature opacity in models of metal-poor asymptotic giant branch stars

    Energy Technology Data Exchange (ETDEWEB)

    Constantino, Thomas; Campbell, Simon; Lattanzio, John [Monash Centre for Astrophysics, School of Mathematical Sciences, Monash University, Victoria 3800 (Australia); Gil-Pons, Pilar, E-mail: thomas.constantino@monash.edu [Department of Applied Physics, Polytechnic University of Catalonia, 08860 Barcelona (Spain)

    2014-03-20

    The vital importance of composition-dependent low-temperature opacity in low-mass (M ≤ 3 M {sub ☉}) asymptotic giant branch (AGB) stellar models of metallicity Z ≥ 0.001 has recently been demonstrated. Its significance to more metal-poor, intermediate-mass (M ≥ 2.5 M {sub ☉}) models has yet to be investigated. We show that its inclusion in lower-metallicity models ([Fe/H] ≤–2) is essential and that there exists no threshold metallicity below which composition-dependent molecular opacity may be neglected. We find it to be crucial in all intermediate-mass models investigated ([Fe/H] ≤–2 and 2.5 ≤ M/M {sub ☉} ≤ 5), because of the evolution of the surface chemistry, including the orders of magnitude increase in the abundance of molecule-forming species. Its effect on these models mirrors that previously reported for higher-metallicity models—increase in radius, decrease in T {sub eff}, faster mass loss, shorter thermally pulsing AGB lifetime, reduced enrichment in third dredge-up products (by a factor of 3-10), and an increase in the mass limit for hot bottom burning. We show that the evolution of low-metallicity models with composition-dependent low-temperature opacity is relatively independent of initial metal abundance because its contribution to the opacity is far outweighed by changes resulting from dredge-up. Our results imply a significant reduction in the expected number of nitrogen-enhanced metal-poor stars, which may help explain their observed paucity. We note that these findings are partially a product of the macrophysics adopted in our models, in particular, the Vassiliadis and Wood mass loss rate which is strongly dependent on radius.

  18. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    Science.gov (United States)

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was 125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA 125 degrees and caution is advocated when using this device in such cases.

  19. No diagnostic utility of antibody patterns against Klebsiella pneumoniae capsular serotypes in patients with axial spondyloarthritis vs. patients with non-specific low back pain

    DEFF Research Database (Denmark)

    Hermansen, L T; Loft, A G; Christiansen, A A

    2017-01-01

    OBJECTIVES: To investigate whether antibody response patterns against Klebsiella pneumoniae capsular serotypes can discriminate patients with axial spondyloarthritis (axSpA) from patients with non-specific low back pain (LBP). METHOD: Immunoglobulin (Ig)G and IgA antibodies against K. pneumoniae...... capsular serotypes K2, K26, K36, and K50 were measured, and antibody seropositivity compared between groups and analysed for patient correlation in five different groups: (a) 96 patients fulfilling the Assessment of SpondyloArthritis International Society (ASAS) classification criteria for axSpA; (b) 38...... ankylosing spondylitis (AS) served as the negative and positive control groups. RESULTS: There was no difference in IgG and IgA seropositivity against all serotypes between the axSpA, non-axSpA, and LBP groups. No significant correlations were found between anti-Klebsiella antibodies and age, gender, HLA-B27...

  20. Opacity and gradients in aluminum wire array z-pinch implosions on the Z pulsed power facility

    Energy Technology Data Exchange (ETDEWEB)

    Ampleford, D. J., E-mail: damplef@sandia.gov; Hansen, S. B.; Jennings, C. A.; Jones, B.; Coverdale, C. A.; Harvey-Thompson, A. J.; Rochau, G. A.; Dunham, G.; Moore, N. W.; Harding, E. C.; Cuneo, M. E. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Chong, Y.-K.; Clark, R. W.; Ouart, N.; Thornhill, J. W.; Giuliani, J.; Apruzese, J. P. [Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-03-15

    Aluminum wire array z pinches imploded on the Z generator are an extremely bright source of 1–2 keV radiation, with close to 400 kJ radiated at photon energies >1 keV and more than 50 kJ radiated in a single line (Al Ly-α). Opacity plays a critical role in the dynamics and K-shell radiation efficiency of these pinches. Where significant structure is present in the stagnated pinch this acts to reduce the effective opacity of the system as demonstrated by direct analysis of spectra. Analysis of time-integrated broadband spectra (0.8–25 keV) indicates electron temperatures ranging from a few 100 eV to a few keV are present, indicative of substantial temperature gradients.

  1. Clinical application of capsular tension ring on cataract surgery in patients with pseudoexfoliation syndrome after trabeculectomy

    Directory of Open Access Journals (Sweden)

    Yi Zhang

    2014-09-01

    Full Text Available AIM:To investigate the safety and efficacy of capsular tension ring(CTRinsertion combined with phacoemulsification and intraocular lens(IOLimplantation in patient with pseudoexfoliation syndrome after anti-glaucoma surgery.METHODS: A retrospective study was conducted of 10 eyes from 10 cataract patients with pseudoexfoliation syndrome following trabeculectomy surgery, and who underwent CTR insertion combined with phacoemulsification and IOL implantation between January, 2012 and June, 2013. All cases had nuclear cataracts(nuclear hardness Ⅱ 1 eye, nuclear hardness Ⅲ 4 eyes, nuclear hardness Ⅳ 5 eyes. One case with Ⅳ nuclear hardness cataract had iridodonesis and lens subluxation. Postoperative visual acuity, intra- and post-operative complications, anterior capsular opening, IOL position, and postoperative intraocular pressure(IOPwere assessed. Follow-ups ranged from 3 to 14mo. The t test was used to analyze the variables studied.RESULTS: All patients had a successful CTR insertion combined with phacoemulsification and IOL implantation. A modified CTR insertion was performed in one case, the others underwent a standard CTR insertion. The best corrected visual acuity(BCVAwas ≥0.5 in 3 eyes and 0.3-t=1.9955, P>0.05. The most common intrao- and post-operative complications were corneal edema, small pupil, residual cortex, spontaneous zonular dialysis.CONCLUSION: Suitable CTR insertion in appropriate occasion may be beneficial to patients with pseudoexfoliation syndrome after trabeculectomy during cataract surgery. It prevents the IOL decentration and decrease the surgical complication. Less complication occurs at the early stage.

  2. Posterior Pole Sparing Laser Photocoagulation Combined with Intravitreal Bevacizumab Injection in Posterior Retinopathy of Prematurity

    Directory of Open Access Journals (Sweden)

    Rebecca Kim

    2014-01-01

    Full Text Available Purpose. To report the results of the posterior pole sparing laser photocoagulation combined with intravitreal bevacizumab injection (IVB in retinopathy of prematurity (ROP. Methods. A retrospective chart review of premature babies with ROP, all of whom received laser photocoagulation with IVB. Eleven eyes of 6 infants with advanced zone I ROP underwent laser ablation sparing posterior pole with concurrent IVB. The results were compared with those of full-laser treatment combined with IVB to 8 eyes of 5 infants with advanced ROP without involvement of the posterior pole. Results. The posterior pole sparing laser with IVB was performed with zone I, stage 3+ ROP at the mean postmenstrual age of 36 weeks and 5 days. The plus sign decreased significantly at postoperative day 1, the neovascular proliferation regressed by postoperative week 1, and the normal vascularization started at postoperative day 32 on the average. Two months after treatment, vascularization of the spared avascular area was completed. There was no macular dragging, tractional retinal detachment, foveal destruction by laser scars, or any other adverse event. No significant anatomical differences were identified from those of full-laser ablation combined with IVB. Conclusions. Posterior pole sparing laser with IVB can give favorable results without destruction of posterior pole retina.

  3. Endoscopic Management of Posterior Epistaxis

    OpenAIRE

    Paul, J.; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-01-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26–50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of ...

  4. Combined special capsular tension ring and toric IOL implantation for management of post-DALK high regular astigmatism with subluxated traumatic cataract

    Directory of Open Access Journals (Sweden)

    Asim Kumar Kandar

    2014-01-01

    Full Text Available We report a case of 18-year-old male who has undergone phacoemulsification with implantation of toric IOL (AcrySof IQ SN6AT9 after fixation of lens capsule with Cionni′s capsular tension ring (CTR for subluxated traumatic cataract with high astigmatism after deep anterior lamellar keratoplasty (DALK. He underwent right eye DALK for advanced keratoconus four years earlier. He had history of trauma one year later with displaced clear crystalline lens into  anterior chamber and graft dehiscence, which was repaired successfully. The graft survived, but patient developed cataract with subluxated lens, for which phacoemulsification with implantation of toric IOL was done. Serial  topography showed regular corneal astigmatism of -5.50 diopter (K 1 42.75 D @130°, K 2 48.25 D @40°. At 10-month follow-up, the patient has BCVA 20/30 with + 0.75 DS/- 1.75 DC @ 110°. The capsular bag is quite stable with well-centered IOL. Combination of Cionni′s ring with toric IOL could be a good option to manage such complex cases.

  5. Combined special capsular tension ring and toric IOL implantation for management of post-DALK high regular astigmatism with subluxated traumatic cataract.

    Science.gov (United States)

    Kandar, Asim Kumar

    2014-07-01

    We report a case of 18-year-old male who has undergone phacoemulsification with implantation of toric IOL (AcrySof IQ SN6AT9) after fixation of lens capsule with Cionni's capsular tension ring (CTR) for subluxated traumatic cataract with high astigmatism after deep anterior lamellar keratoplasty (DALK). He underwent right eye DALK for advanced keratoconus four years earlier. He had history of trauma one year later with displaced clear crystalline lens into  anterior chamber and graft dehiscence, which was repaired successfully. The graft survived, but patient developed cataract with subluxated lens, for which phacoemulsification with implantation of toric IOL was done. Serial  topography showed regular corneal astigmatism of -5.50 diopter (K 1 42.75 D @130°, K 2 48.25 D @40°). At 10-month follow-up, the patient has BCVA 20/30 with + 0.75 DS/- 1.75 DC @ 110°. The capsular bag is quite stable with well-centered IOL. Combination of Cionni's ring with toric IOL could be a good option to manage such complex cases.

  6. Aplicación de una biblioteca de anticuerpos lineales humanos frente al polisacárido capsular de Neisseria meningitidis serogrupo B

    Directory of Open Access Journals (Sweden)

    Emigdio León-Toirac

    2013-12-01

    Full Text Available Neisseria meningitidis serogrupo B produce aún morbimortalidad significativa. Su polisacárido capsular muestra similitud estructural con proteínas humanas y pobre inmunogenicidad, obstaculizando así el desarrollo de vacunas y anticuerpos monoclonales (AcM y policlonales contra esta bacteria. Recientemente se han creado bibliotecas artificiales de anticuerpos humanos expresados en bacteriófagos que reconocen específicamente a moléculas diana existentes, con la ventaja sobre los AcM convencionales por su rápida obtención, sin utilización de animales de laboratorio, lo que emerge como alternativa atractiva para la producción de AcM contra antígenos peculiares o complejos. Se realizó un trabajo de investigación básica, utilizando una biblioteca de fagos filamentosos que expresan constitutivamente regiones variables de anticuerpos humanos, que se enfrentó al polisacárido capsular de N. meningitidis serogrupo B. Los resultados que se obtuvieron mediante ELISA policlonal sugieren la existencia de anticuerpos humanos expresados en fagos que lo reconocen.

  7. Penerapan Bahasa Alami Sederhana pada Online Public Access Catalog (Opac) Berbasis Web Semantik

    OpenAIRE

    Andri, Andri

    2012-01-01

    Online Public Access Catalog (OPAC) merupakan sistem katalog online yang memanfaatkan teknologi komputer dan internet sebagai media pengaksesan dan penyimpanan datanya. Sebuah katalog biasanya memberikan informasi mengenai koleksi yang disimpan dalam sebuah perpustakaan digital. Dalam penelitian ini akan dibuat sebuah prototipe aplikasi pencarian pada katalog online di perpustakaan Universitas Binadarma Palembang berbasis teknologi web semantik serta menerapkan pengolahan bahasa alami sederha...

  8. Research on Spectroscopy, Opacity, and Atmospheres

    Science.gov (United States)

    Kurucz, Robert L.

    2005-01-01

    I propose to continue providing observers with basic data for interpreting spectra from stars, novas, supernovas, clusters, and galaxies. These data will include allowed and forbidden line lists, both laboratory and computed, for the first five to ten ions of all atoms and for all relevant diatomic molecules. I will eventually expand to all ions of the first thirty elements to treat far UV and X-ray spectra, and for envelope opacities. I also include triatomic molecules provided by other researchers. I have also made CDs with Partridge and Schwenke's water data for work on UV stars. The line data also serve as input to my model atmosphere and synthesis programs that generate energy distributions, photometry, limb darkening, and spectra that can be used for planning observations and for fitting observed spectra. The spectrum synthesis programs produce detailed plots with the lines identified. Grids of stellar spectra can be used for radial velocity-, rotation-, or abundance templates and for population synthesis. I am fitting spectra of bright stars to test the data and to produce atlases to guide observers. For each star the whole spectrum is computed from the UV to the far IR. The line data, opacities, models, spectra, and programs are freely distributed on CDs and on my Web site and represent a unique resource for many NASA programs. I am now in full production of new line lists for atoms. I am computing all ions of all elements from H to Zn and the first 5 ions of all the heavier elements, about 800 ions. For each ion I treat as many as 61 even and 61 odd configurations, computing all energy levels and eigenvectors. The Hamiltonian is determined from a scaled-Hartree-Fock starting guess by least squares fitting the observed energy levels. The average energy of each configuration is used in computing scaled-Thomas-Fermi-Dirac wavefunctions for each configuration which in turn are used to compute allowed and forbidden transition integrals. These are multiplied

  9. Digitisation of films and texture analysis for digital classification of pulmonary opacities

    International Nuclear Information System (INIS)

    Desaga, J.F.; Dengler, J.; Wolf, T.; Engelmann, U.; Scheppelmann, D.; Meinzer, H.P.

    1988-01-01

    The study aimed at evaluating the effect of different methods of digitisation of radiographic films on the digital classification of pulmonary opacities. Test sets from the standard of the International Labour Office (ILO) Classification of Radiographs of Pneumoconiosis were prepared by film digitsation using a scanning microdensitometer or a video digitiser based on a personal computer equipped with a real time digitiser board and a vidicon or a Charge Coupled Device (CCD) camera. Seven different algorithms were used for texture analysis resulting in 16 texture parameters for each region. All methods used for texture analysis were independent of the mean grey value level and the size of the image analysed. Classification was performed by discriminant analysis using the classes from the ILO classification. A hit ratio of at least 85% was achieved for a digitisation by scanner digitisation or the vidicon, while the corresponding results of the CCD camera were significantly less good. Classification by texture analysis of opacities of chest X-rays of pneumoconiosis digitised by a personal computer based video digitiser and a vidicon are of equal quality compared to digitisation by a scanning microdensitometer. Correct classification of 90% was achieved via the described statistical approach. (orig.) [de

  10. Constraining the Dust Opacity Law in Three Small and Isolated Molecular Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Webb, K. A.; Thanjavur, K. [Department of Physics and Astronomy, 3800 Finnerty Road, University of Victoria, Victoria, BC, V8P 5C2 (Canada); Di Francesco, J. [National Research Council of Canada, Herzberg Institute of Astrophysics, 5071 West Saanich Road, Victoria, BC, V9E 2E7 (Canada); Sadavoy, S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Launhardt, R.; Vicente, J. Abreu; Kainulainen, J. [Max-Planck-Institut für Astronomy, Königstuhl 17, D-69117, Heidelberg (Germany); Shirley, Y. [Steward Observatory, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Stutz, A., E-mail: kawebb@uvic.ca [Departmento de Astronomìa, Facultad Ciencias Físicas y Matemáticas, Universidad de Concepción, Av. Esteban Iturra s/n Barro Universitario, Casilla 160-C, Concepción (Chile)

    2017-11-01

    Density profiles of isolated cores derived from thermal dust continuum emission rely on models of dust properties, such as mass opacity, that are poorly constrained. With complementary measures from near-infrared extinction maps, we can assess the reliability of commonly used dust models. In this work, we compare Herschel -derived maps of the optical depth with equivalent maps derived from CFHT WIRCAM near-infrared observations for three isolated cores: CB 68, L 429, and L 1552. We assess the dust opacities provided from four models: OH1a, OH5a, Orm1, and Orm4. Although the consistency of the models differs between the three sources, the results suggest that the optical properties of dust in the envelopes of the cores are best described by either silicate and bare graphite grains (e.g., Orm1) or carbonaceous grains with some coagulation and either thin or no ice mantles (e.g., OH5a). None of the models, however, individually produced the most consistent optical depth maps for every source. The results suggest that either the dust in the cores is not well-described by any one dust property model, the application of the dust models cannot be extended beyond the very center of the cores, or more complex SED fitting functions are necessary.

  11. Bony landmark between the attachment of the medial meniscus posterior root and the posterior cruciate ligament: CT and MR imaging assessment

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Masataka; Furumatsu, Takayuki; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi [Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Department of Orthopaedic Surgery, Science of Functional Recovery and Reconstruction, Okayama (Japan)

    2017-08-15

    (1) To reveal the prevalence of the bony recess (posterior dimple) and (2) to determine the position of the posterior dimple on the tibial plateau using three-dimensional computed tomography (3DCT). In this study, a retrospective review of 112 patients was performed to identify the posterior dimple and to evaluate its position on 3DCT. Magnetic resonance images (MRIs) were also used to determine the positional relationship among the posterior cruciate ligament (PCL), medial meniscus posterior insertion (MMPI), and posterior dimple. The posterior dimple was observed in 100 of 112 knees (89.3%) on 3DCT. The center of the posterior dimple was 13.6 ± 0.8 mm from the medial tibial eminence apex. MRI showed that the posterior dimple separated the tibial attachment of the PCL and MMPI. This is the first study to discuss the prevalence and position of the bony recess in the posterior intercondylar fossa. (orig.)

  12. Bony landmark between the attachment of the medial meniscus posterior root and the posterior cruciate ligament: CT and MR imaging assessment

    International Nuclear Information System (INIS)

    Fujii, Masataka; Furumatsu, Takayuki; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-01-01

    (1) To reveal the prevalence of the bony recess (posterior dimple) and (2) to determine the position of the posterior dimple on the tibial plateau using three-dimensional computed tomography (3DCT). In this study, a retrospective review of 112 patients was performed to identify the posterior dimple and to evaluate its position on 3DCT. Magnetic resonance images (MRIs) were also used to determine the positional relationship among the posterior cruciate ligament (PCL), medial meniscus posterior insertion (MMPI), and posterior dimple. The posterior dimple was observed in 100 of 112 knees (89.3%) on 3DCT. The center of the posterior dimple was 13.6 ± 0.8 mm from the medial tibial eminence apex. MRI showed that the posterior dimple separated the tibial attachment of the PCL and MMPI. This is the first study to discuss the prevalence and position of the bony recess in the posterior intercondylar fossa. (orig.)

  13. A case of traction retinal detachment in a patient with Gaucher disease.

    Science.gov (United States)

    Watanabe, Akira; Gekka, Tamaki; Arai, Kota; Tsuneoka, Hiroshi

    2017-01-01

    This is the first report of vitreous surgery for traction retinal detachment in a patient with type III Gaucher disease with multiple vitreous opacities. A 16-year-old boy who was diagnosed with Gaucher disease at age two and was undergoing enzyme replacement therapy presented with numerous white opacities of varying sizes in the vitreous bodies of both eyes. Visual acuity was 20/40 in the right eye and 20/2000 in the left eye. The retina of the left eye was completely detached, and vitreous surgery was performed. Liquefaction of the vitreous body was advanced, and the central part of the vitreous cavity contained almost no vitreous humor. The macular region was successfully aspirated with a vitreous cutter to form a posterior vitreous detachment. From the optic disk to the nasal side, however, posterior vitreous detachment formation was prevented by strong adhesions between the retina and the vitreous body. The traction retinal detachment of the posterior fundus improved after vitreous body resection alone. Traction retinal detachment may occur as a result of severe vitreous liquefaction in cases of Gaucher disease with numerous vitreous opacities.

  14. Relationship between the Intracellular Integrity and the Morphology of the Capsular Envelope in Attached and Free-Living Marine Bacteria

    OpenAIRE

    Heissenberger, A.; Leppard, G. G.; Herndl, G. J.

    1996-01-01

    The integrity of the intracellular structures and the presence and dimension of the capsular envelope were investigated in marine snow-associated and marine free-living bacteria by transmission electron microscopy and special fixation techniques. Three categories depending on the presence of internal structures were differentiated. In marine snow, 51% of the marine snow-associated bacterial community was considered intact, 26% had a partly degraded internal structure, and 23% were empty with ...

  15. Primary Posterior Mediastinum Hydatid Cyst

    International Nuclear Information System (INIS)

    Ahmed, M.; Eid, A. F.; Sheikh, M. Y.; Yiannakou, N.

    2014-01-01

    Primary posterior mediastinal hydatid cyst is a serious health problem for the Mediterranean countries. We diagnosed a case of a 46-year-old female with a primary posterior mediastinum hydatid cyst on CT and MRI. It was provisionally identified as either a hydatid cyst or bronchogenic cyst or neuroenteric cyst. CT guided aspiration with 18 gauge needle confirmed as hydatid sand. This is very rare in this population but it should be kept in mind when one is looking at any cyst in the posterior mediastinum. (author)

  16. Influence of artificial accelerated aging on the color stability and opacity of composites of different shades.

    Science.gov (United States)

    Mundim, F M; Da Fonseca Roberti Garcia, L; Silva Sousa, A B; Cruvinel, D R; De Carvalho Panzeri Pires-De-Souza, F

    2010-10-01

    The aim of this study was to evaluate the influence of artificial accelerated aging on the color stability and opacity of composites of different shades. Four composites for direct use (Heliomolar, 4 Seasons, Tetric EvoCeram; QuiXfil) and one for indirect use (SR Adoro) in two shades were used: light (A2) and dark (C3 for direct, and D4 for indirect composite). QuiXfil was obtained in Universal shade. A Teflon matrix (12 X 2 mm) was used to obtain 54 specimens (N=6), which were submitted to color and opacity analysis (Spectrophotometer PCB 6807, Byk Gardner) before and after artificial accelerated aging for 384 hours. After the statistical analysis (2-way ANOVA - Bonferroni - PArtificial accelerated aging interfered in the optical properties assessed; however, the alterations seemed to be more related to the composites composition than to their shade.

  17. Significance of lenticular opacity from the view point of the exposure dose of A-bomb radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Hospital, Hiroshima (Japan)

    1975-04-01

    Two cases of lenticular opacity were discussed from the view point of exposure dose of A-bomb radiation. Case 1: female, 22 year and 5 months old when she was exposured to A-bomb radiation. The presumed exposure dose was 482.0 rad. Cataract due to A-bomb radiation. Case 2: female, 21 years and 6 months old when she was exposured to A-bomb radiation. The presumed exposure dose was more than 1,000 rad. Cataract due to A-bomb radiation and incipient cataract senilis. It was reported here that there was a marked difference in opacity findings of cataract due to A-bomb radiation in accordance with difference in exposure dose of radiation. It was also presumed from the findings of incipient cataract senilis that with increasing exposure dose, the aging phenomenon was promoted.

  18. The detection of the capsular tear at the undersurface of the extensor carpi radialis brevis tendon in chronic tennis elbow: the value of magnetic resonance imaging and computed tomography arthrography.

    Science.gov (United States)

    Sasaki, Koichi; Tamakawa, Mitsuharu; Onda, Kazunori; Iba, Kosuke; Sonoda, Tomoko; Yamashita, Toshihiko; Wada, Takuro

    2011-04-01

    This study compared the diagnostic efficacy of magnetic resonance imaging (MRI) and computed tomography arthrography (CTA) in the assessment of capsular tears at the undersurface of the extensor carpi radials brevis tendon in chronic tennis elbow using arthroscopy as a gold standard. Because of the higher spatial resolution of CT, we hypothesized that CTA is superior to MRI for assessing capsular tears. We retrospectively reviewed 19 consecutive patients with chronic tennis elbow with preoperative MRI and CTA studies who underwent arthroscopic surgery. Three observers with different levels of training and experience (musculoskeletal radiologist, experienced elbow surgeon, and hand fellow) evaluated the capsular tear by MRI and CTA in a blinded manner. The results of the MRI and CTA were compared and the agreement among the 3 observers was determined using an intraclass correlation coefficient (ICC). Then, the results of the MRI and CTA examinations were compared with the intraoperative findings of the arthroscopic examination. The sensitivity, specificity, and κ value were calculated. The ICC of CTA (0.855) was superior to MRI (0.645). The sensitivity, specificity, and κ value of CTA were superior to those of MRI in each of the 3 observers. The κ value was 0.79, 0.89, and 0.79 for CTA, and 0.48, 0.48, and 0.27 for MRI for the radiologist, surgeon, and fellow, respectively. CTA was a reliable and accurate diagnostic modality compared with MRI to detect the capsular tear in patients with chronic tennis elbow. CTA was less influenced by the observer's experience. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  19. Treatment implications of posterior fossa ependymoma subgroups.

    Science.gov (United States)

    Ramaswamy, Vijay; Taylor, Michael D

    2016-11-15

    Posterior fossa ependymoma comprises two distinct molecular entities, ependymoma_posterior fossa A (EPN_PFA) and ependymoma_posterior fossa B (EPN_PFB), with differentiable gene expression profiles. As yet, the response of the two entities to treatment is unclear. To determine the relationship between the two molecular subgroups of posterior fossa ependymoma and treatment, we studied a cohort of 820 patients with molecularly profiled, clinically annotated posterior fossa ependymomas. We found that the strongest predictor of poor outcome in patients with posterior fossa ependymoma across the entire age spectrum was molecular subgroup EPN_PFA, which was recently reported in the paper entitled "Therapeutic impact of cytoreductive surgery and irradiation of posterior fossa ependymoma in the molecular era: a retrospective multicohort analysis" in the Journal of Clinical Oncology. Patients with incompletely resected EPN_PFA tumors had a very poor outcome despite receiving adjuvant radiation therapy, whereas a substantial proportion of patients with EPN_PFB tumors can be cured with surgery alone.

  20. ‘Seeing the Dark’: Grounding Phenomenal Transparency and Opacity in Precision Estimation for Active Inference

    Science.gov (United States)

    Limanowski, Jakub; Friston, Karl

    2018-01-01

    One of the central claims of the Self-model Theory of Subjectivity is that the experience of being someone – even in a minimal form – arises through a transparent phenomenal self-model, which itself can in principle be reduced to brain processes. Here, we consider whether it is possible to distinguish between phenomenally transparent and opaque states in terms of active inference. We propose a relationship of phenomenal opacity to expected uncertainty or precision; i.e., the capacity for introspective attention and implicit mental action. Thus we associate introspective attention with the deployment of ‘precision’ that may render the perceptual evidence (for action) opaque, while treating transparency as a necessary aspect of beliefs about action, i.e., ‘what I am’ doing. We conclude by proposing how we may have to nuance our conception of minimal phenomenal selfhood and agency in light of this active inference conception of transparency-opacity. PMID:29780343

  1. Andrographolide suppresses epithelial mesenchymal transition by ...

    Indian Academy of Sciences (India)

    Epithelial mesenchymal transition (EMT) of lens epithelial cells (LECs) may contribute to the development of posterior capsular opacification (PCO), which leads to visual impairment. Andrographolide has been shown to have therapeutic potential against various cancers. However, its effect on human LECs is still unknown.

  2. Posterior column reconstruction improves fusion rates at the level of osteotomy in three-column posterior-based osteotomies.

    Science.gov (United States)

    Lewis, Stephen J; Mohanty, Chandan; Gazendam, Aaron M; Kato, So; Keshen, Sam G; Lewis, Noah D; Magana, Sofia P; Perlmutter, David; Cape, Jennifer

    2018-03-01

    To determine the incidence of pseudarthrosis at the osteotomy site after three-column spinal osteotomies (3-COs) with posterior column reconstruction. 82 consecutive adult 3-COs (66 patients) with a minimum of 2-year follow-up were retrospectively reviewed. All cases underwent posterior 3-COs with two-rod constructs. The inferior facets of the proximal level were reduced to the superior facets of the distal level. If that was not possible, a structural piece of bone graft either from the local resection or a local rib was slotted in the posterior column defect to re-establish continual structural posterior bone across the lateral margins of the resection. No interbody cages were used at the level of the osteotomy. There were 34 thoracic osteotomies, 47 lumbar osteotomies and one sacral osteotomy with a mean follow-up of 52 (24-126) months. All cases underwent posterior column reconstructions described above and the addition of interbody support or additional posterior rods was not performed for fusion at the osteotomy level. Among them, 29 patients underwent one or more revision surgeries. There were three definite cases of pseudarthrosis at the osteotomy site (4%). Six revisions were also performed for pseudarthrosis at other levels. Restoration of the structural integrity of the posterior column in three-column posterior-based osteotomies was associated with > 95% fusion rate at the level of the osteotomy. Pseudarthrosis at other levels was the second most common reason for revision following adjacent segment disease in the long-term follow-up.

  3. The Belfast atomic data bank, recommended data, and the opacity project data base

    International Nuclear Information System (INIS)

    Berrington, K.A.; Kingston, A.E.; Sawey, P.M.J.

    1991-01-01

    The Belfast Atomic Data Bank holds data for the excitation and ionisation of atoms and ions by electrons and photons, and provides recommended data; electron excitation data recommended at regular Atomic Data Workshops is summarised. Photoabsorption data for all elements up to Fe have been calculated in the international Opacity Project, and a summary is given of the atomic data expected from the Project

  4. Facoemulsificación e implante de lente intraocular en cataratas causadas por uveitis Phacoemulsification and intraocular lens implantation in patients with cataract caused by uveitis

    Directory of Open Access Journals (Sweden)

    Dayamí Pérez Gómez

    2008-06-01

    treatment indicated anti-inflammatory drugs. Phacoemulsification with intraocular lens implantation was performed (PMMA, optic 6 mm; during the follow-up period of 24 hours to 6 months, steroidal anti-inflammatory, non-steroids and immunosuppressive drugs were prescribed to patients for 6 weeks. RESULTS: A number of alterations were observed in the anterior segment secondary to uveitis (postsurgical, unspecific, Fuch´s heterochromic cyclitis, postraumatic, Reiter´s syndrome, caused by toxoplasmosis and other infectious choroiditis and by juvenile rheumatoid arthritis. No postsurgical recurrence of uveitis was found in 9 eyes (24.3 %. The complications were related to uveitis, surgery, inflammatory activity and capsular epithelium reaction. Posterior capsular opacity occurred in 11 patients (29.7 % associated to younger age. Individual recovery was satisfactory in 30 (81.1 % patients who improved their vision, that is, 0.8-1.0 in 28 and 0.5-0.6 in 2 (5.4 % patients. CONCLUSIONS: Phacoemulsification with intraocular lens implantation is very useful to treat cataract after uveitis since surgical reaction is low, inflammation is under control and good results are achieved in addition to anatomophysiological rearrangement of the anterior segment.

  5. From stellar plasmas to laboratory plasmas: application to X and XUV opacity measurements

    International Nuclear Information System (INIS)

    Loisel, G.

    2011-01-01

    The general context of this thesis is the one of radiative properties of high energy density matter. Energy densities involved (>10 11 J/cm 3 ) implies that a large part of energy exchange goes through radiation-matter interactions. My studies deal with spectral opacity, a fundamental parameter for modelling stellar interiors and constitute a propitious observable to experimental tests of theoretical descriptions of hot and dense plasmas physics. Although the main application of my work is stellar plasmas it can be useful for plasma diagnostics in inertial confinement fusion. My work activities are centred on the experimental study of opacities of plasmas at local thermodynamic equilibrium for temperature conditions of a few tens eV (a few 100000 K) and a few mg/cm 3 in matter density. Plasmas are obtained in conditions as homogenous as possible using the radiative heating of a laser-irradiated cavity. Heating is provided through a laser beam of high energy (100-300 J) and with relatively long pulse duration of a few nanosecond. For such measurements we could benefit from the LULI lasers configuration coupling the nanosecond beam with a picosecond one used to perform on a short duration the measurement of the plasma transmission. The use of short pulse laser to produce a short time radiography beam was a first achievement for this kind of experience. In the spectral range of keV photons, absorbing transitions 2p-3d or 3d-4f of elements of moderate or high atomic number have been probed. They present absorption structures which shape results mainly of the competition between spin-orbit splitting and statistical broadening effects. It appeared that this competition depends strongly on the atomic number Z. Thus for similar plasma parameters we explored opacities of Iron, Nickel, Copper and Germanium (Z around 30) in a first series of measurement and the one of Barium, Samarium and Gadolinium (Z around 60) in a second campaign

  6. Exome Array Analysis of Nuclear Lens Opacity.

    Science.gov (United States)

    Loomis, Stephanie J; Klein, Alison P; Lee, Kristine E; Chen, Fei; Bomotti, Samantha; Truitt, Barbara; Iyengar, Sudha K; Klein, Ronald; Klein, Barbara E K; Duggal, Priya

    2018-06-01

    Nuclear cataract is the most common subtype of age-related cataract, the leading cause of blindness worldwide. It results from advanced nuclear sclerosis, or opacity in the center of the optic lens, and is affected by both genetic and environmental risk factors, including smoking. We sought to understand the genetic factors associated with nuclear sclerosis through interrogation of rare and low frequency coding variants using exome array data. We analyzed Illumina Human Exome Array data for 1,488 participants of European ancestry in the Beaver Dam Eye Study who were without cataract surgery for association with nuclear sclerosis grade, controlling for age and sex. We performed single-variant regression analysis for 32,138 variants with minor allele frequency (MAF) ≥0.003. In addition, gene-based analysis of 11,844 genes containing at least two variants with MAF nuclear sclerosis, the possible association with the RNF149 gene highlights a potential candidate gene for future studies that aim to understand the genetic architecture of nuclear sclerosis.

  7. One stage rescue procedure after capsular contracture of breast implants with autologous fat grafts collected by water assisted liposuction (“BEAULI Method”

    Directory of Open Access Journals (Sweden)

    Ueberreiter, Klaus

    2013-01-01

    Full Text Available With increasing number of patients with silicone implants for breast augmentation or reconstruction we are confronted with more and more cases of capsular contracture. Not every case is resolved by resection of the capsule and exchange of implants. Many patients rather bear the consequences of severe fibrosis than to have their implants removed. The one stage procedure of implant removal and lipofilling proved to be highly efficient with good to excellent results and high patient satisfaction. Between January 2008 and October 2012 a total of 64 patients (124 breasts with capsular fibrosis Baker III to IV were treated with autologous fat grafts collected with the body-jet by water-assisted liposuction (“BEAULI Method”. Magnetic resonance imaging (MRI of the breasts was performed in 5 patients preoperatively and 6 month postoperatively, a clinical examination and photo documentation of all patients was done on day 1 and after 4 weeks, 12 weeks and 6 months postoperatively. The procedure included implant removal and lipofilling of the subcutaneous and intramuscular space in a single procedure by means of the BEAULI Method. The average gross amount of grafted fat was 260 ml. The average drainage time was one day. The shape of the breast changed to a more natural and ptotic form. Negative side effects like oily cysts or infections were not observed. The time of the overall procedure including liposuction was 70±15 min. Reoccurring capsular contracture is one of the hazards in plastic surgery. Until now the treatment of choice after more than two failed implant changes combined with resection of the capsule is usually the final removal of implants with or without possible additional autologous tissue transfer (microvascular flaps. We could add a relatively simple and efficient procedure to resolve and improve those cases by autologous fat transfer using water-assisted liposuction and the BEAULI Method.

  8. Delivering Electronic Resources with Web OPACs and Other Web-based Tools: Needs of Reference Librarians.

    Science.gov (United States)

    Bordeianu, Sever; Carter, Christina E.; Dennis, Nancy K.

    2000-01-01

    Describes Web-based online public access catalogs (Web OPACs) and other Web-based tools as gateway methods for providing access to library collections. Addresses solutions for overcoming barriers to information, such as through the implementation of proxy servers and other authentication tools for remote users. (Contains 18 references.)…

  9. We Never Have to Say Goodbye: Finding a Place for OPACS in Discovery Environments

    Science.gov (United States)

    Matthews, J. Greg

    2009-01-01

    It is easy to lament the shortcomings of traditional online public access catalogs (OPACs) in the Google Age. Users cannot, for example, usually input a snippet of a long-forgotten pop song's chorus into an online library catalog and almost instantly retrieve a relevant result along with hundreds of other options. On the other hand, should OPACs…

  10. Fabrication of a Micro-Fluid Gathering Tool for the Gastrointestinal Juice Sampling Function of a Versatile Capsular Endoscope

    Directory of Open Access Journals (Sweden)

    Dong-il Dan Cho

    2011-07-01

    Full Text Available This paper presents a micro-fluid gathering tool for a versatile capsular endoscope that employs a solid chemical propellant, azobisisobutyronitrile (AIBN. The proposed tool consists of a micro-heater, an AIBN matrix, a Venturi tube, a reservoir, an inlet, and an outlet. The micro-heater heats the AIBN matrix to be decomposed into by-products and nitrogen gas. This nitrogen gas generates negative pressure passing through the Venturi tube. The generated negative pressure inhales a target fluid from around the inlet into the reservoir. All the parts are designed to be embedded inside a cylindrical shape with a diameter of 17 mm and a height of 2.3 mm in order to integrate it into a versatile developmental capsular endoscope without any scaledown. Two sets of the proposed tools are fabricated and tested: one is made of polydimethylsiloxane (PDMS and the other is made of polymethylmethacrylate (PMMA. In performance comparisons, the PDMS gathering tool can withstand a stronger pulling force, and the PMMA gathering tool requires a less negative pressure for inhaling the same target fluid. Due to the instant and full activation of the thin AIBN matrix, both types of gathering tool show analogous performance in the sample gathering evaluation. The gathered volume is approximately 1.57 μL using approximately 25.4 μL of AIBN compound.

  11. Fabrication of a micro-fluid gathering tool for the gastrointestinal juice sampling function of a versatile capsular endoscope.

    Science.gov (United States)

    Koo, Kyo-In; Lee, Sangmin; Cho, Dong-il Dan

    2011-01-01

    This paper presents a micro-fluid gathering tool for a versatile capsular endoscope that employs a solid chemical propellant, azobisisobutyronitrile (AIBN). The proposed tool consists of a micro-heater, an AIBN matrix, a Venturi tube, a reservoir, an inlet, and an outlet. The micro-heater heats the AIBN matrix to be decomposed into by-products and nitrogen gas. This nitrogen gas generates negative pressure passing through the Venturi tube. The generated negative pressure inhales a target fluid from around the inlet into the reservoir. All the parts are designed to be embedded inside a cylindrical shape with a diameter of 17 mm and a height of 2.3 mm in order to integrate it into a versatile developmental capsular endoscope without any scaledown. Two sets of the proposed tools are fabricated and tested: one is made of polydimethylsiloxane (PDMS) and the other is made of polymethylmethacrylate (PMMA). In performance comparisons, the PDMS gathering tool can withstand a stronger pulling force, and the PMMA gathering tool requires a less negative pressure for inhaling the same target fluid. Due to the instant and full activation of the thin AIBN matrix, both types of gathering tool show analogous performance in the sample gathering evaluation. The gathered volume is approximately 1.57 μL using approximately 25.4 μL of AIBN compound.

  12. Preliminary study of a new intraocular method in the diagnosis and treatment of Propionibacterium acnes endophthalmitis following cataract extraction.

    Science.gov (United States)

    Owens, S L; Lam, S; Tessler, H H; Deutsch, T A

    1993-04-01

    Late endophthalmitis, due to Propionibacterium acnes, developed in three patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens (PC-IOL) insertion. Cultures from the capsular bag yielded P. acnes in all three. With topical anesthesia and through an anterior chamber paracentesis, culture specimens were taken from and clindamycin irrigated into the capsular bag. Filtered 100% oxygen was introduced into the anterior chamber in two; the third also received an injection of gentamicin and dexamethasone into the capsular bag. After treatment, two patients received oral antibiotics; one received hyperbaric oxygen therapy. Visual acuity was improved and inflammation reduced in all three. However, after treatment, ocular toxic effects due to clindamycin were suspected in one. This approach offers several clear advantages, including topical anesthesia, outpatient management, elimination of the need for vitrectomy, and retention of the intraocular lens (IOL).

  13. Glued intrascleral fixation of posterior chamber intraocular lens in children.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Prakash, Dimple; Prakash, Gaurav; Jacob, Soosan; Agarwal, Athiya

    2012-04-01

    To evaluate the short-term results of glued intrascleral fixation of posterior chamber intraocular lens (glued IOL) in children without adequate capsular support. Noncomparative retrospective observational case series. Institutional practice. Forty-one eyes of 33 children who underwent glued IOL implantation were retrospectively evaluated. The indications were postsurgical aphakia, subluxated cataract, ectopia lentis, traumatic subluxation, and decentered IOL. Visual acuity (VA), endothelial cell changes, intraoperative and postoperative complications. The mean age at the time of glued IOL was 10.7±3.6 years (range 5-15). The mean duration of follow-up after surgery was 17.5±8.5 months (range 12-36). The mean postoperative best spectacle-corrected visual acuity (BCVA in decimal equivalent) was 0.43±0.33 and there was significant change noted (P20/60 BCVA was obtained in 17.1% and 46.3% of eyes respectively. BCVA improvement more than 1 line was seen in 22 eyes (53.6%). The mean postoperative refraction was myopic (-1.19±0.7 diopters [D]) in 19 eyes and hyperopic (+1.02±0.7 D) in 22 eyes. The mean endothelial loss was 4.13% (range 1.3%-5.94%). The 3 causes of reduced BCVA were the preexisting corneal, retinal pathology, and amblyopia. Postoperative complications included optic capture in 1 eye (2.4%), macular edema in 2 eyes (4.8%), and clinical decentration in 2 eyes (4.8%). There was no postoperative retinal detachment, IOL dislocation, endophthalmitis, or glaucoma. Short-term results in children after glued IOL were favorable, with a low rate of complications. However, regular follow-ups are required since long-term risks are unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Trans trochanteric approach with coronal osteotomy of the great trochanter: A new technique for extra-capsular trochanteric fracture patients treated by total hip arthroplasty (THA) in elderly.

    Science.gov (United States)

    Steffann, Francois; Prudhon, Jean-Louis; Puch, Jean-Marc; Ferreira, André; Descamps, Loys; Verdier, Régis; Caton, Jacques

    2015-06-05

    Several surgical approaches could be used in hip arthroplasty or trauma surgery: anterior, anterolateral, lateral, posterior (with or without trochanterotomy), using or not an orthopedic reduction table. Subtrochanteric and extra-capsular trochanteric fractures (ECTF) are usually treated by internal fixation with mandatory restrictions on weight bearing. Specific complications have been widely described. Mechanical failures are particularly high in unstable fractures. Hip fractures are a major public health issue with a mortality rate of 12%-23% at 1 year. An alternative option is to treat ECTF by total hip arthroplasty (THA) to prevent decubitus complications, to help rapid recovery, and to permit immediate weight bearing as well as quick rehabilitation. However, specific risks of THA have to be considered such as dislocation or cardiovascular failure. The classical approach (anterior or posterior) requires the opening of the joint and capsule, weakening hip stability and the repair of the great trochanter is sometimes hazardous. For 15 years, we have been treating unstable ECTF by THA with cementless stem, dual mobility cup (DMC), greater trochanter (GT) reattachment, and a new surgical approach preserving capsule, going through the fracture and avoiding joint dislocation. Bombaci first described a similar approach in 2008; our trans fractural digastric approach (medial gluteus and lateral vastus) is different. A coronal GT osteotomy is performed when there is no coronal fracture line. It allows easy access to the femoral neck and acetabulum. The THA is implanted without femoral internal rotation to avoid extra bone fragment displacement. With pre-operative planning, cup implantation is easy and stem positioning is adjusted referring to the top of the GT after trial reduction and preoperative planning. The longitudinal osteotomy and trochanteric fracture are repaired with wires and the digastric incision is closed. This variant of Bombaci approach could be use

  15. Protection against Escherichia coli K1 infection in newborn rats by antibody to K1 capsular polysaccharide antigen.

    OpenAIRE

    Bortolussi, R; Ferrier, P

    1980-01-01

    The protective value of antibody to the K1 capsular polysaccharide antigen of Escherichia coli was investigated in a newborn rat model of E. coli K1 infection. Pregnant rats were immunized intravenously with E. coli, and the agglutinating titer to meningococcal group B polysaccharide, which is identical to K1 polysaccharide, was measured in the serum of rats and their offspring. Convalescent serum from rat mothers showed an increased antibody titer in animals injected twice but not once with ...

  16. Endoscopic management of posterior epistaxis.

    Science.gov (United States)

    Paul, J; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-04-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26-50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of the bleeding vessel. Of these, in four cases unsuspected diagnosis was made. Of the remaining 19, in three patients, the bleeding point could not be localized accurately and these patients were managed by anteroposterior packing. The rest of the 16 patients were managed by endoscopic cauterization. In four patients, there was recurrence of bleeding within 24 h. In one of these, cauterization controlled the bleeding while in the rest nasal packing had to be resorted to. Thus, of the 23 patients of posterior epistaxis subjected to nasal endoscopy, we could avoid nasal packing in 17 (74%). To conclude, endoscopic nasal cauterization is recommended as the first line to treatment in all cases of posterior epistaxis. This will not only prevent the uncomfortable and potentially dangerous nasal packing but also help in finding the underlying pathology.

  17. Management of posterior urethral disruption injuries.

    Science.gov (United States)

    Myers, Jeremy B; McAninch, Jack W

    2009-03-01

    Posterior urethral disruption is a traumatic injury to the male urethra, which most often results from pelvic fracture. After trauma, the distraction defect between the two ends of the urethra often scars and becomes fibrotic, blocking the urethra and bladder emptying. Increasing evidence suggests that many posterior urethral disruptions occur at the junction between the membranous urethra and the bulbar urethra, which is distal to the rhabdosphincter. In the acute setting, when a posterior urethral disruption is suspected, retrograde urethrography should be performed. Posterior urethral disruptions can be managed acutely by realignment of the urethra over a urethral catheter or by placement of a suprapubic catheter for bladder drainage only. Once fibrosis has stabilized, the patient can undergo posterior urethroplasty. In most cases, this procedure can be performed via a perineal approach in a single-stage surgery. The results of this single-stage perineal urethroplasty are excellent, and a patent urethra can be re-established in the majority of men who undergo surgery.

  18. Author Details

    African Journals Online (AJOL)

    Abstract PDF · Vol 16, No 1 (2002) - Articles Outcome of extra-capsular cataract extraction with posterior chamber intraocular lens implantation performed at a cataract surgical campaign. Abstract PDF · Vol 15, No 2 (2001) - Articles Prevalence of strabismus among pre-school children community in Butajira Town

  19. Opacity calculations for laser plasma applications

    International Nuclear Information System (INIS)

    Magee, N.H. Jr.

    1986-01-01

    The Los Alamos LTE light element detailed configuration opacity code (LEDCOP) has been revised to provide more accurate absorption coefficients and group means for modern radiation-hydrodynamic codes. The new group means will be especially useful for computing the transport of thermal radiation from laser deposition. The principal improvement is the inclusion of a complete set of accurate and internally consistent LS term energies and oscillator strengths in both the EOS and absorption coefficients. Selected energies and oscillator strengths were calculated from a Hartree-Fock code, then fitted by a quantum defect method. This allowed transitions at all wavelengths to be treated consistently and accurately instead of being limited to wavelength regions covered by experimental observations or isolated theoretical calculations. A second improvement is the use of more accurate photoionization cross sections for excited as well as ground state configurations. These cross sections are now more consistent with the bound-bound oscillator strengths, leading to a smooth transition across the continuum limit. Results will be presented showing the agreement of the LS term energies and oscillator strengths with observed values. The new absorption coefficients will be compared with previous calculations. 5 refs., 9 figs., 1 tab

  20. Delayed Single Stage Perineal Posterior Urethroplasty.

    Science.gov (United States)

    Ali, Shahzad; Shahnawaz; Shahzad, Iqbal; Baloch, Muhammad Umar

    2015-06-01

    To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Descriptive case series. Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patient's age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3%) experienced recurrent stricture during first 10 months. Five (16.6%) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6%) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3% with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures.

  1. Hematomas na fossa craniana posterior Haematomata in the posterior fossa

    Directory of Open Access Journals (Sweden)

    Mário S. Cademartori

    1969-09-01

    Full Text Available São relatados 6 casos de hematomas sub-tentorias (um de hematoma subdural crônico, quatro de hematomas intra-cerebelares, um de hematoma extra-dural. Salientando a pequena freqüência dos hematomas da fossa craniana posterior, o autor mostra a necessidade de vários exames complementares para o diagnóstico exato, indispensável para a aplicação de terapêutica cirúrgica adequada.Six cases of sub-tentorial haematomata (one chronic sub-dural, four intra-cerebellar, one extra-dural are reported. Emphasizing the relative rarity of haematomata in the posterior cranial fossa, the author claims the necessity of complementary examinations for proper diagnosis, indispensable for adequate surgical treatment.

  2. Posterior encephalopathy with vasospasm: MRI and angiography

    International Nuclear Information System (INIS)

    Weidauer, S.; Gaa, J.; Lanfermann, H.; Zanella, F.E.; Sitzer, M.; Hefner, R.

    2003-01-01

    Posterior encephalopathy is characterised by headache, impairment of consciousness, seizures and progressive visual loss. MRI shows bilateral, predominantly posterior, cortical and subcortical lesions with a distribution. Our aim was to analyse the MRI lesion pattern and angiographic findings because the pathophysiology of posterior encephalopathy is incompletely understood. We report three patients with clinical and imaging findings consistent with posterior encephalopathy who underwent serial MRI including diffusion-weighted imaging (DWI) and construction of apparent diffusion coefficient (ADC) maps, and four-vessel digital subtraction angiography (DSA). DWI revealed symmetrical subcortical and cortical parieto-occipital high signal. High and also low ADCs indicated probable vasogenic and cytotoxic oedema. On follow-up there was focal cortical laminar necrosis, while the white-matter lesions resolved almost completely, except in the arterial border zones. DSA revealed diffuse arterial narrowing, slightly more marked in the posterior circulation. These findings suggest that posterior encephalopathy may in some cases be due to diffuse, severe vasospasm affecting especially in the parieto-occipital grey matter, with its higher vulnerability to ischemia. Cerebral vasospasm due to digitoxin intoxication, resulting in posterior encephalopathy, has not yet been described previously. (orig.)

  3. Measuring the iron spectral opacity in solar conditions using a double ablation front scheme

    Energy Technology Data Exchange (ETDEWEB)

    Colaitis, A. [Centre Lasers Intenses et Applications, Talence (France); CEA/DRF/IRFU/DAp, CEA Saclay (France); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Ducret, J. E. [Centre Lasers Intenses et Applications, Talence (France); CEA/DRF/IRFU/DAp, CEA Saclay (France); Turck-Chieze, S [CEA/DRF/IRFU/DAp, CEA Saclay (France); Pennec, M L [CEA/DRF/IRFU/DAp, CEA Saclay (France); CEA/DIF, Arpajon (France); Blancard, C [CEA/DIF, Arpajon (France)

    2018-01-22

    We propose a new method to achieve hydrodynamic conditions relevant for the investigation of the radiation transport properties of the plasma at the base of the solar convection zone. The method is designed in the framework of opacity measurements with high-power lasers and exploits the temporal and spatial stability of hydrodynamic parameters in counter-propagating Double Ablation Front (DAF) structures.

  4. Impact of Internet Search Engines on OPAC Users: A Study of Punjabi University, Patiala (India)

    Science.gov (United States)

    Kumar, Shiv

    2012-01-01

    Purpose: The aim of this paper is to study the impact of internet search engine usage with special reference to OPAC searches in the Punjabi University Library, Patiala, Punjab (India). Design/methodology/approach: The primary data were collected from 352 users comprising faculty, research scholars and postgraduate students of the university. A…

  5. One-stage posterior approaches for treatment of thoracic spinal infection: Transforaminal and costotransversectomy, compared with anterior approach with posterior instrumentation.

    Science.gov (United States)

    Kao, Fu-Cheng; Tsai, Tsung-Ting; Niu, Chi-Chien; Lai, Po-Liang; Chen, Lih-Huei; Chen, Wen-Jer

    2017-10-01

    Treating thoracic infective spondylodiscitis with anterior surgical approaches carry a relatively high risk of perioperative and postoperative complications. Posterior approaches have been reported to result in lower complication rates than anterior procedures, but more evidence is needed to demonstrate the safety and efficacy of 1-stage posterior approaches for treating infectious thoracic spondylodiscitis.Preoperative and postoperative clinical data, of 18 patients who underwent 2 types of 1-stage posterior procedures, costotransversectomy and transforaminal thoracic interbody debridement and fusion and 7 patients who underwent anterior debridement and reconstruction with posterior instrumentation, were retrospectively assessed.The clinical outcomes of patients treated with 1-stage posterior approaches were generally good, with good infection control, back pain relief, kyphotic angle correction, and either partial or solid union for fusion status. Furthermore, they achieved shorter surgical time, fewer postoperative complications, and shorter hospital stay than the patients underwent anterior debridement with posterior instrumentation.The results suggested that treating thoracic spondylodiscitis with a single-stage posterior approach might prevent postoperative complications and avoid respiratory problems associated with anterior approaches. Single-stage posterior approaches would be recommended for thoracic spine infection, especially for patients with medical comorbidities.

  6. Influence of Projection Operator on Oxygen Line Shapes and its effect on Rosseland-Mean Opacity in Stellar Interiors

    Science.gov (United States)

    Gomez, Thomas; Nagayama, Taisukue; Kilcrease, David; Hansen, Stephanie; Montgomery, Mike; Winget, Don

    2018-01-01

    The Rosseland-Mean opacity (RMO) is an important quantity in determining radiation transport through stars. The solar-convection-zone boundary predicted by the standard solar model disagrees with helioseismology measurements by many sigma; a 14% increase in the RMO would resolve this discrepancy. Experiments at Sandia National Laboratories are now measuring iron opacity at solar-interior conditions, and significant discrepancies are already observed. Highly-ionized oxygen is one of the dominant contributions to the RMO. The strongest line, Lyman alpha, is at the peak of the Rosseland weighting function. The accuracy of line-broadening calculations has been called into question due to various experimental results and comparisons between theory. We have developed an ab-initio calculation to explore different physical effects, our current focus is treating penetrating collisions explicitly. The equation of motion used to calculate line shapes within the relaxation and unified theories includes a projection operator, which performs an average over plasma electron states; this is neglected due to past calculations approximate treatment of penetrations. We now include this projection term explicitly, which results in a significant broadening of spectral lines from highly-charged ions (low-Z elements are not much affected). The additional broadening raises the O Ly-alpha wing opacity by a factor of 5; we examine the consequences of this additional broadening on the Rosseland mean.

  7. Third dredge-up in cluster AGB stars : observational constraints and improved opacity data for models

    International Nuclear Information System (INIS)

    Lederer, M. T.

    2009-01-01

    evolution calculations with our findings. The second part of the thesis deals with a new set of low-temperature mean opacity coefficients. Until recently, the change in chemistry due to the TDU in the cool layers of the star, where molecules are the dominant opacity source, has been neglected in almost all stellar evolution models. I show that already within a certain chemistry regime (i. e. an oxygen-rich or carbon-rich metal mixture) an alteration of the carbon abundance causes, due to the special role of the CO molecule, considerable changes in the Rosseland opacity which has distinct consequences for the stellar structure and evolution. In the stellar evolution models, the most pronounced effect can be expected when the TDU turns the initially oxygen-rich object into a carbon star. The new opacity database contains (beside a variation of the 12 C mass fraction) also tables with a varied abundance of 14 N. After describing the database as well as the tools and the data used for its computation, I point out the implications of the new opacity data for stellar evolution models. (author) [de

  8. Spondylolisthesis and Posterior Instability

    International Nuclear Information System (INIS)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D.; Simons, P.; Kuchta, J.

    2009-01-01

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI

  9. Spondylolisthesis and Posterior Instability

    Energy Technology Data Exchange (ETDEWEB)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D. (Privatpraxis fuer Upright MRT, Koeln (Germany)); Simons, P.; Kuchta, J. (Media Park Klinik, Koeln (Germany))

    2009-04-15

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI.

  10. αA-crystallin R49Cneo mutation influences the architecture of lens fiber cell membranes and causes posterior and nuclear cataracts in mice

    Directory of Open Access Journals (Sweden)

    Andley Usha P

    2009-07-01

    Full Text Available Abstract Background αA-crystallin (CRYAA/HSPB4, a major component of all vertebrate eye lenses, is a small heat shock protein responsible for maintaining lens transparency. The R49C mutation in the αA-crystallin protein is linked with non-syndromic, hereditary human cataracts in a four-generation Caucasian family. Methods This study describes a mouse cataract model generated by insertion of a neomycin-resistant (neor gene into an intron of the gene encoding mutant R49C αA-crystallin. Mice carrying the neor gene and wild-type Cryaa were also generated as controls. Heterozygous knock-in mice containing one wild type gene and one mutated gene for αA-crystallin (WT/R49Cneo and homozygous knock-in mice containing two mutated genes (R49Cneo/R49Cneo were compared. Results By 3 weeks, WT/R49Cneo mice exhibited large vacuoles in the cortical region 100 μm from the lens surface, and by 3 months posterior and nuclear cataracts had developed. WT/R49Cneo mice demonstrated severe posterior cataracts at 9 months of age, with considerable posterior nuclear migration evident in histological sections. R49Cneo/R49Cneo mice demonstrated nearly complete lens opacities by 5 months of age. In contrast, R49C mice in which the neor gene was deleted by breeding with CreEIIa mice developed lens abnormalities at birth, suggesting that the neor gene may suppress expression of mutant R49C αA-crystallin protein. Conclusion It is apparent that modification of membrane and cell-cell interactions occurs in the presence of the αA-crystallin mutation and rapidly leads to lens cell pathology in vivo.

  11. Traumatic lesions of the posterior urethra.

    Science.gov (United States)

    Velarde-Ramos, L; Gómez-Illanes, R; Campos-Juanatey, F; Portillo-Martín, J A

    2016-11-01

    The posterior urethral lesions are associated with pelvis fractures in 5-10% of cases. The posterior urethra is attached to the pelvis bone by puboprostatic ligaments and the perineal membrane, which explains why disruption of the pelvic ring can injure the urethra at this level. To identify suspected cases of posterior urethral trauma and to perform the diagnosis and its immediate or deferred management. Search in PubMed of articles related to traumatic posterior urethral lesions, written in English or Spanish. We reviewed the relevant publications including literature reviews and chapters from books related to the topic. With patients with pelvis fractures, we must always rule out posterior urethral lesions. The diagnostic examination of choice is retrograde urethrography, which, along with the severity of the condition, will determine the management in the acute phase and whether the treatment will be performed immediately or deferred. Early diagnosis and proper acute management decrease the associated complications, such as strictures, urinary incontinence and erectile dysfunction. Despite the classical association between posterior urethral lesions and pelvic fractures, the management of those lesions (whether immediate or deferred) remains controversial. Thanks to the growing interest in urethral disease, there are an increasing number of studies that help us achieve better management of these lesions. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Delayed Single Stage Perineal Posterior Urethroplasty

    International Nuclear Information System (INIS)

    Ali, S.; Shahnawaz; Shahzad, I.; Baloch, M. U.

    2015-01-01

    Objective: To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Study Design: Descriptive case series. Place and Duration of Study: Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Methodology: Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Results: Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patients age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3 percentage) experienced recurrent stricture during first 10 months. Five (16.6 percentage) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6 percentage) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3 percentage with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Conclusion: Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures. (author)

  13. DNA-Sequence Based Typing of the Cronobacter Genus Using MLST, CRISPR-cas Array and Capsular Profiling

    Directory of Open Access Journals (Sweden)

    Pauline Ogrodzki

    2017-09-01

    Full Text Available The Cronobacter genus is composed of seven species, within which a number of pathovars have been described. The most notable infections by Cronobacter spp. are of infants through the consumption of contaminated infant formula. The description of the genus has greatly improved in recent years through DNA sequencing techniques, and this has led to a robust means of identification. However some species are highly clonal and this limits the ability to discriminate between unrelated strains by some methods of genotyping. This article updates the application of three genotyping methods across the Cronobacter genus. The three genotyping methods were multilocus sequence typing (MLST, capsular profiling of the K-antigen and colanic acid (CA biosynthesis regions, and CRISPR-cas array profiling. A total of 1654 MLST profiled and 286 whole genome sequenced strains, available by open access at the PubMLST Cronobacter database, were used this analysis. The predominance of C. sakazakii and C. malonaticus in clinical infections was confirmed. The majority of clinical strains being in the C. sakazakii clonal complexes (CC 1 and 4, sequence types (ST 8 and 12 and C. malonaticus ST7. The capsular profile K2:CA2, previously proposed as being strongly associated with C. sakazakii and C. malonaticus isolates from severe neonatal infections, was also found in C. turicensis, C. dublinensis and C. universalis. The majority of CRISPR-cas types across the genus was the I-E (Ecoli type. Some strains of C. dublinensis and C. muytjensii encoded the I-F (Ypseudo type, and others lacked the cas gene loci. The significance of the expanding profiling will be of benefit to researchers as well as governmental and industrial risk assessors.

  14. DNA-Sequence Based Typing of the Cronobacter Genus Using MLST, CRISPR-cas Array and Capsular Profiling.

    Science.gov (United States)

    Ogrodzki, Pauline; Forsythe, Stephen J

    2017-01-01

    The Cronobacter genus is composed of seven species, within which a number of pathovars have been described. The most notable infections by Cronobacter spp. are of infants through the consumption of contaminated infant formula. The description of the genus has greatly improved in recent years through DNA sequencing techniques, and this has led to a robust means of identification. However some species are highly clonal and this limits the ability to discriminate between unrelated strains by some methods of genotyping. This article updates the application of three genotyping methods across the Cronobacter genus. The three genotyping methods were multilocus sequence typing (MLST), capsular profiling of the K -antigen and colanic acid (CA) biosynthesis regions, and CRISPR- cas array profiling. A total of 1654 MLST profiled and 286 whole genome sequenced strains, available by open access at the PubMLST Cronobacter database, were used this analysis. The predominance of C. sakazakii and C. malonaticus in clinical infections was confirmed. The majority of clinical strains being in the C. sakazakii clonal complexes (CC) 1 and 4, sequence types (ST) 8 and 12 and C. malonaticus ST7. The capsular profile K2:CA2, previously proposed as being strongly associated with C. sakazakii and C. malonaticus isolates from severe neonatal infections, was also found in C. turicensis , C. dublinensis and C. universalis . The majority of CRISPR- cas types across the genus was the I-E (Ecoli) type. Some strains of C. dublinensis and C. muytjensii encoded the I-F (Ypseudo) type, and others lacked the cas gene loci. The significance of the expanding profiling will be of benefit to researchers as well as governmental and industrial risk assessors.

  15. Epidural hematomas of posterior fossa

    Directory of Open Access Journals (Sweden)

    Radulović Danilo

    2004-01-01

    Full Text Available Background. Posterior fossa epidural hematomas represent 7-14% of all traumatic intracranial epidural hematomas. They are most frequently encountered posttraumatic mass lesions in the posterior fossa. The aim of this study was to identify clinical features that could lead to the early diagnosis of posterior fossa epidural hematoma. Methods. Between 1980 and 2002, 28 patients with epidural hematoma of the posterior fossa were operated on at the Institute for Neurosurgery, Belgrade. Clinical course neuroradiological investigations, and the results of surgical treatment of the patients with posterior fossa epidural hematomas were analyzed retrospectively. Results. Almost two thirds of patients were younger than 16 years of age. In 20 cases injury was caused by a fall, in 6 cases by a traffic accident, and in 2 by the assault. Clinical course was subacute or chronic in two thirds of the patients. On the admission Glasgow Coma Scale was 7 or less in 9 injured, 8-14 in 14 injured, and 15 in 5 injured patients. Linear fracture of the occipital bone was radiographically evident in 19 patients, but was intraoperatively encountered in all the patients except for a 4-year old child. In 25 patients the diagnosis was established by computer assisted tomography (CAT and in 3 by vertebral angiography. All the patients were operated on via suboccipital craniotomy. Four injured patients who were preoperatively comatose were with lethal outcome. Postoperatively, 24 patients were with sufficient neurologic recovery. Conclusion. Posterior fossa epidural hematoma should be suspected in cases of occipital injury, consciousness disturbances, and occipital bone fracture. In such cases urgent CAT-scan is recommended. Early recognition early diagnosis, and prompt treatment are crucial for good neurological recovery after surgery.

  16. Posterior alien hand syndrome: case report

    International Nuclear Information System (INIS)

    Rohde, S.; Weidauer, S.; Lanfermann, H.; Zanella, F.

    2002-01-01

    The alien hand syndrome (AHS) is involuntary uncontrolled movement of an arm with a sense of estrangement from the limb itself. AHS was initially used to describe interhemispheric disconnection phenomena in patients with lesions in the anterior corpus callosum, but it has been found in patients with posterior cerebral lesions without involvement of the corpus callosum, for example parietal infarcts or corticobasal degeneration. The posterior alien hand syndrome is less frequent and presents with nonpurposive behaviour like lifting the arm or writhing fingers. We report an 80-year-old woman with a posterior AHS of the dominant right hand. MRI showed atrophy of the pre- and postcentral gyri without involvement of the corpus callosum. We discuss the aetiology of the posterior AHS and the differences from the anterior varieties. (orig.)

  17. MRI of paraventricular white matter lesions in amyotrophic lateral sclerosis. Analysis by diffusion-weighted images

    International Nuclear Information System (INIS)

    Segawa, Fuminori; Kinoshita, Masao; Kishibayashi, Jun; Kamada, Kazuhiko; Sunohara, Nobuhiko.

    1994-01-01

    Magnetic resonance images in some cases of amyotrophic lateral sclerosis (ALS) revealed abnormal signals in both the paraventriculer white matter and in the posterior limbs of the internal capsule. We examined T 2 - and diffusion-weighted MR images of these lesions in 18 cases of ALS. There were symmetrical high-signal areas in the posterior limbs of the internal capsule in all of the cases. The high-signal areas in the internal capsule corresponded to the pyramidal tracts in the anatomical atlas by Talairach. In 5 of the cases of ALS, T 2 -weighted MR images showed discrete paraventricular white matter lesions as well. The mean age of the ALS patients with paraventricular white matter lesions was higher than that of the ALS patients without such lesions. Proton densities calculated from the conventional MR images were higher in both the capsular and paraventricular lesions. The diffusion coefficients perpendicular to the pyramidal tract in the internal capsular lesions were within the normal range, where as the diffusion coefficients in the paraventricular lesions were increased in all directions. Thus, diffusion anisotropy was lost in the paraventricular lesions. These findings are similar to those observed in the white matter lesions of cerebro-vascular origin. As a result, the pathology of the paraventricular lesions in ALS was confirmed to be different from that of the internal capsular lesions. (author)

  18. MRI of paraventricular white matter lesions in amyotrophic lateral sclerosis. Analysis by diffusion-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Segawa, Fuminori; Kinoshita, Masao (Toho Univ., Tokyo (Japan). Ohashi Hospital); Kishibayashi, Jun; Kamada, Kazuhiko; Sunohara, Nobuhiko

    1994-09-01

    Magnetic resonance images in some cases of amyotrophic lateral sclerosis (ALS) revealed abnormal signals in both the paraventriculer white matter and in the posterior limbs of the internal capsule. We examined T[sub 2]- and diffusion-weighted MR images of these lesions in 18 cases of ALS. There were symmetrical high-signal areas in the posterior limbs of the internal capsule in all of the cases. The high-signal areas in the internal capsule corresponded to the pyramidal tracts in the anatomical atlas by Talairach. In 5 of the cases of ALS, T[sub 2]-weighted MR images showed discrete paraventricular white matter lesions as well. The mean age of the ALS patients with paraventricular white matter lesions was higher than that of the ALS patients without such lesions. Proton densities calculated from the conventional MR images were higher in both the capsular and paraventricular lesions. The diffusion coefficients perpendicular to the pyramidal tract in the internal capsular lesions were within the normal range, where as the diffusion coefficients in the paraventricular lesions were increased in all directions. Thus, diffusion anisotropy was lost in the paraventricular lesions. These findings are similar to those observed in the white matter lesions of cerebro-vascular origin. As a result, the pathology of the paraventricular lesions in ALS was confirmed to be different from that of the internal capsular lesions. (author).

  19. Two-year outcomes of open shoulder anterior capsular reconstruction for instability from severe capsular deficiency.

    Science.gov (United States)

    Dewing, Christopher B; Horan, Marilee P; Millett, Peter J

    2012-01-01

    To document outcomes after anterior capsulolabral reconstruction for recurrent shoulder instability in 15 patients (20 shoulders) who have had multiple failed stabilizations or collagen disorders. Twenty shoulders with recurrent instability underwent revision stabilization with allograft reconstruction of anterior capsulolabral structures, which re-creates the labrum and capsular ligaments. The patients comprised 3 men and 12 women (mean age, 26 years [range, 18 to 38 years]) in whom multiple prior repairs failed and who had disability from continued pain and instability. Patients could choose to undergo either arthrodesis or salvage allograft reconstruction or to live with permanent disability. Of the patients, 5 had Ehlers-Danlos syndrome whereas 10 had hyperlaxity syndromes without genetic confirmation. Failure was defined as further instability surgery. Pain, shoulder function, instability (dislocations/subluxation), and American Shoulder and Elbow Surgeons scores were documented. At follow-up, 9 of 20 shoulders (45%) remained stable. Recurrent instability was reported in 5 shoulders (25%), but the patients chose not to undergo further surgery. In the 14 shoulders without further stabilization (nonfailures), the mean American Shoulder and Elbow Surgeons score increased 43 points at a mean of 3.8 years (range, 2 to 6 years) postoperatively (P failed by progressing to instability surgery at a mean of 8.6 months (range, 2.8 to 24 months). In the 6 shoulders that failed, the mean number of prior surgeries was 8 (range, 3 to 15) compared with a mean of 4 prior surgeries (range, 1 to 16) for the 9 nonfailures. Treating patients in whom multiple stabilizations have failed remains challenging. In our series 9 shoulders (45%) remained completely stable at 3.8 years. Recurrent instability (3 reinjuries) requiring further stabilization occurred in 6 (30%). Subsequent treatment for non-instability reasons was performed in 3 (15%). Instability was reported but revision

  20. Versatility of Capsular Flaps in the Salvage of Exposed Breast Implants

    Directory of Open Access Journals (Sweden)

    Beniamino Brunetti, MD

    2015-03-01

    Full Text Available Summary: Breast implant exposure due to poor tissue coverage or previous irradiation represents a surgical challenge both in the reconstructive and aesthetic plastic surgery practice. In case of implant extrusion or incipient exposure, the commonly suggested strategies, such as targeted antibiotic therapy, drainage and lavage of the cavity, fistulectomy, and primary closure, may be ineffective leading the surgeon to an unwanted implant removal or to adopt more invasive flap coverage procedures. Breast implant capsule, in its physiological clinical behavior, can be considered as a new reliable source of tissue, which can be used in a wide range of clinical situations. In our hands, capsular flaps proved to be a versatile solution not only to treat breast contour deformities or inframammary fold malpositions but also to salvage exposed breast implants. In this scenario, the use of more invasive surgical techniques can be avoided or simply saved and delayed for future recurrences.(Plast Reconstr Surg Glob Open 2015;3:e340; doi:10.1097/GOX.0000000000000307; Published online 30 March 2015.

  1. Antibodies to Staphylococcus aureus Serotype 8 Capsular Polysaccharide React with and Protect against Serotype 5 and 8 Isolates

    OpenAIRE

    Park, Saeyoung; Gerber, Sabina; Lee, Jean C.

    2014-01-01

    Most Staphylococcus aureus isolates produce either a serotype 5 (CP5) or 8 (CP8) capsular polysaccharide, and the CP antigens are targets for vaccine development. Since CP5 and CP8 have similar trisaccharide repeating units, it is important to identify an epitope shared by both CP5 and CP8. To characterize cross-reactivity between CP5 and CP8, the immunogenicity of CP5 and CP8 conjugate vaccines in mice and rabbits was evaluated by serological assays. Immune sera were also tested for function...

  2. Distrofia corneana amorfa posterior: relato de caso Posterior amorphous corneal dystrophy: case report

    Directory of Open Access Journals (Sweden)

    Lauro Augusto de Oliveira

    2006-12-01

    Full Text Available O objetivo deste trabalho é alertar o oftalmologista da possibilidade de se deparar com casos raros de distrofias corneanas. Neste caso correlacionamos os achados clínicos da distrofia amorfa posterior com refração, topografia e biomicroscopia ultra-sônica.The purpose of this paper is to warn the ophthalmologist about the possibility of facing rare cases of corneal dystrophies. Clinical findings of a case of posterior amorphous dystrophy were correlated with refraction, topography, and ultrasound biomicroscopy.

  3. Congenital abnormalities of the posterior fossa.

    Science.gov (United States)

    Bosemani, Thangamadhan; Orman, Gunes; Boltshauser, Eugen; Tekes, Aylin; Huisman, Thierry A G M; Poretti, Andrea

    2015-01-01

    The frequency and importance of the evaluation of the posterior fossa have increased significantly over the past 20 years owing to advances in neuroimaging. Nowadays, conventional and advanced neuroimaging techniques allow detailed evaluation of the complex anatomic structures within the posterior fossa. A wide spectrum of congenital abnormalities has been demonstrated, including malformations (anomalies due to an alteration of the primary developmental program caused by a genetic defect) and disruptions (anomalies due to the breakdown of a structure that had a normal developmental potential). Familiarity with the spectrum of congenital posterior fossa anomalies and their well-defined diagnostic criteria is crucial for optimal therapy, an accurate prognosis, and correct genetic counseling. The authors discuss the spectrum of posterior fossa malformations and disruptions, with emphasis on neuroimaging findings (including diagnostic criteria), neurologic presentation, systemic involvement, prognosis, and risk of recurrence. RSNA, 2015

  4. "Garbage" In, "Refuse and Refuse Disposal" Out: Making the Most of the Subject Authority File in OPAC.

    Science.gov (United States)

    Horn, Marguerite E.

    2002-01-01

    Discusses the difference in subject access in OPACs (online public access catalogs) between subject searching (authority, alphabetic, or controlled vocabulary) versus keyword searching (uncontrolled, free text, natural language vocabulary). Compares a query on the term "garbage" in two online catalogs and discusses results. (Author/LRW)

  5. Observation of femoral and tibial insertion of the posterior cruciate ligament by using conventional CT and transparent 3D-CT

    International Nuclear Information System (INIS)

    Inoue, Masayuki; Tsukuda, Koichiro; Yasojima, Nobutoshi; Oota, Masahiro; Kasahara, Yasuhiko

    2011-01-01

    Presented are image data acquisitioned by the volume rendering (VR)-3D-CT and authors' transparent (T)-3D-CT to depict the bone contour, of medial intercondylar ridge (MIR) and posterior intercodylar fossa (PIF) at femoral and tibial insertion, respectively, of the posterior cruciate ligament (PCL) as those data are helpful for planning the reconstruction surgery of PCL and for confirming the femoral PCL insertion by using the C-arm during operation. Helical scanning is conducted with GE MD-CT (64DAS) to reconstruct VR-3D-CT image with the workstation ZIO's ZIO900M Quadra and T-3D-CT image, by reducing the opacity by pixel exclusion of the intraosseous lumen. MIR is observed in all 70 normal knees tested in VR-3D-CT and the bifurcate ridge, in 15 knees among them. In T-3D-CT image, distance data of the origin of MIR from Blumensaat's line and the angle of MIR and bone axis are calculated and presented. In VR-3D-CT and T-3D-CT images of PIF from 20 knees, actual measures of PIF slope angle (degree), PIF area ratio to joint surface (JS) (%), distance from JS to centers of anterolateral (AL) and posterolateral (PM) slopes (mm), and from medial and lateral JS to PIF posterior border (mm), and distance ratios of PM and AL to medial and lateral tibia, respectively, (%) are calculated and presented. Findings are: MIR originates at 45% distal point of Blumensaat's line; the articular line crosses with PIF at its center in T-3D-CT sagittal plane; centers of tibial AL and PM exist at the middle of frontal plane, and at 1.00 and 5.5 mm, respectively, distal points of JS of sagittal plane. The PIF data are rather comparable to those obtained in cadavers reported in 3 literatures and the present procedure is concluded to be valid. (author)

  6. A Longitudinal Study of the Effects of OPAC Screen Changes on Searching Behavior and Searcher Success.

    Science.gov (United States)

    Blecic, Deborah D.; Dorsch, Josephine L.; Koenig, Melissa H.; Bangalore, Nimala S.

    1999-01-01

    Describes a longitudinal study of four sets of OPAC (online public access catalog) transaction logs that examined the effects of screen changes in helping searchers improve their search behavior. Results show that while screen changes initially had a positive impact on search behavior, they were not always sustained over time. (Author/LRW)

  7. An Empirical Determination of the Intergalactic Background Light Using Near-Infrared Deep Galaxy Survey Data Out to 5 Micrometers and the Gamma-Ray Opacity of the Universe

    Science.gov (United States)

    Scully, Sean T.; Malkan, Matthew A.; Stecker, Floyd W.

    2014-01-01

    We extend our previous model-independent determination of the intergalactic background light, based purely on galaxy survey data, out to a wavelength of 5 micrometers. Our approach enables us to constrain the range of photon densities, based on the uncertainties from observationally determined luminosity densities and colors. We further determine a 68% confidence upper and lower limit on the opacity of the universe to gamma-rays up to energies of 1.6/(1 + z) terraelectron volts. A comparison of our lower limit redshift-dependent opacity curves to the opacity limits derived from the results of both ground-based air Cerenkov telescope and Fermi-LAT observations of PKS 1424+240 allows us to place a new upper limit on the redshift of this source, independent of IBL modeling.

  8. Proving Opacity of Transactional Memory with Early Release

    Directory of Open Access Journals (Sweden)

    Siek Konrad

    2015-12-01

    Full Text Available Transactional Memory (TM is an alternative way of synchronizing concurrent accesses to shared memory by adopting the abstraction of transactions in place of low-level mechanisms like locks and barriers. TMs usually apply optimistic concurrency control to provide a universal and easy-to-use method of maintaining correctness. However, this approach performs a high number of aborts in high contention workloads, which can adversely affect performance. Optimistic TMs can cause problems when transactions contain irrevocable operations. Hence, pessimistic TMs were proposed to solve some of these problems. However, an important way of achieving efficiency in pessimistic TMs is to use early release. On the other hand, early release is seemingly at odds with opacity, the gold standard of TM safety properties, which does not allow transactions to make their state visible until they commit. In this paper we propose a proof technique that makes it possible to demonstrate that a TM with early release can be opaque as long as it prevents inconsistent views.

  9. Posterior Probability Matching and Human Perceptual Decision Making.

    Directory of Open Access Journals (Sweden)

    Richard F Murray

    2015-06-01

    Full Text Available Probability matching is a classic theory of decision making that was first developed in models of cognition. Posterior probability matching, a variant in which observers match their response probabilities to the posterior probability of each response being correct, is being used increasingly often in models of perception. However, little is known about whether posterior probability matching is consistent with the vast literature on vision and hearing that has developed within signal detection theory. Here we test posterior probability matching models using two tools from detection theory. First, we examine the models' performance in a two-pass experiment, where each block of trials is presented twice, and we measure the proportion of times that the model gives the same response twice to repeated stimuli. We show that at low performance levels, posterior probability matching models give highly inconsistent responses across repeated presentations of identical trials. We find that practised human observers are more consistent across repeated trials than these models predict, and we find some evidence that less practised observers more consistent as well. Second, we compare the performance of posterior probability matching models on a discrimination task to the performance of a theoretical ideal observer that achieves the best possible performance. We find that posterior probability matching is very inefficient at low-to-moderate performance levels, and that human observers can be more efficient than is ever possible according to posterior probability matching models. These findings support classic signal detection models, and rule out a broad class of posterior probability matching models for expert performance on perceptual tasks that range in complexity from contrast discrimination to symmetry detection. However, our findings leave open the possibility that inexperienced observers may show posterior probability matching behaviour, and our methods

  10. Retention of the posterior cruciate ligament versus the posterior stabilized design in total knee arthroplasty: a prospective randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    van den Akker-Scheek Inge

    2009-09-01

    Full Text Available Abstract Background Prosthetic design for the use in primary total knee arthroplasty has evolved into designs that preserve the posterior cruciate ligament (PCL and those in which the ligament is routinely sacrificed (posterior stabilized. In patients with a functional PCL the decision which design is chosen depends largely on the favour and training of the surgeon. The objective of this study is to determine whether the patient's perceived outcome and speed of recovery differs between a posterior cruciate retaining total knee arthroplasty and a posterior stabilized total knee arthroplasty. Methods/Design A randomized controlled trial will be conducted. Patients who are admitted for primary unilateral TKA due to primary osteoarthrosis are included when the following inclusion criteria are met: non-fixed fixed varus or valgus deformity less than 10 degrees, age between 55 and 85 years, body mass index less than 35 kg/m2 and ASA score (American Society of Anaesthesiologists I or II. Patients are randomized in 2 groups. Patients in the posterior cruciate retaining group will receive a prosthesis with a posterior cut-out for the posterior cruciate ligament and relatively flat topography. In patients allocated to the posterior stabilized group, in which the posterior cruciate ligament is excised, the design may substitute for this function by an intercondylar tibial prominence that articulates with the femur in flexion. Measurements will take place preoperatively and 6 weeks, 3 months, 6 months and 1 year postoperatively. At all measurement points patient's perceived outcome will be assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC. Secondary outcome measures are quality of life (SF-36 and physician reported functional status and range of motion as determined with the Knee Society Clinical Rating System (KSS. Discussion In the current practice both posterior cruciate retaining and posterior stabilized designs

  11. AKSES JENIS DOKUMEN PADA BASIS DATA TERPADU: SUATU TINJAUAN TERHADAP OPAC DI PDII-LIPI

    Directory of Open Access Journals (Sweden)

    Ade Kohar

    2012-07-01

    Full Text Available Integrated data base is a data base records bibliographic data of several types of document like textbook, periodicals, proceedings, research report, thesis, and article. Purposes of this study were to investigate document type description and searching strategy in integrated data base of online public access catalogs (OPAC in PDII-LIPI, and to know user opinion about that data base existence. It used observation and interviews to 100 data base users to collect data. Result of this study stated that document type description in OPAC was not indexed, so users couldn't do information searching of special type of document directly in the data base. There was only one method could be used to search information of special type of document. User could select it from some information records on the computer screen as the result of document title, author name or subject searching in the data base. This information access method was not efficient. So document type description and indexing was an important factor and should be done in information retrieval system using integrated data base. But respondent majority (84% in PDII-LIPI stated that they liked using separated data base to search information of special type of document.

  12. Biomechanical Effects of Posterior Condylar Offset and Posterior Tibial Slope on Quadriceps Force and Joint Contact Forces in Posterior-Stabilized Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Kyoung-Tak Kang

    2017-01-01

    Full Text Available This study aimed to determine the biomechanical effect of the posterior condylar offset (PCO and posterior tibial slope (PTS in posterior-stabilized (PS fixed-bearing total knee arthroplasty (TKA. We developed ±1, ±2, and ±3 mm PCO models in the posterior direction and −3°, 0°, 3°, and 6° PTS models using a previously validated FE model. The influence of changes in the PCO and PTS on the biomechanical effects under deep-knee-bend loading was investigated. The contact stress on the PE insert increased by 14% and decreased by 7% on average as the PCO increased and decreased, respectively, compared to the neutral position. In addition, the contact stress on post in PE insert increased by 18% on average as PTS increased from −3° to 6°. However, the contact stress on the patellar button decreased by 11% on average as PTS increased from −3° to 6° in all different PCO cases. The quadriceps force decreased by 14% as PTS increased from −3° to 6° in all PCO models. The same trend was found in patellar tendon force. Changes in PCO had adverse biomechanical effects whereas PTS increase had positive biomechanical effects. However, excessive PTS should be avoided to prevent knee instability and subsequent failure.

  13. Atomic data base and the U.K.-U.S. opacity project

    Science.gov (United States)

    Pradhan, A. K.

    1988-08-01

    With the primary aim of calculating stellar envelope opacities, a joint international collaboration is under way for the calculation of basic atomic data for radiative processes: oscillator strengths, photoionization cross sections, energy levels, radiative damping constants (including line broadening). Atomic calculations have been completed for the first ten isoelectronic sequences, H-like to Ne-like, going up to iron, and work is in progress on the third and fourth row atoms and isosequences. The close-coupling approximation is employed throughout using a new version of the R-matrix method. Particular emphasis is placed on the detailed resolution of the autoionization structures in the bound-free continuum.

  14. CT findings of posterior pararenal effusion

    International Nuclear Information System (INIS)

    Koh, Byung Hee; Cho, On Koo; Kim, Sonn Yong

    1990-01-01

    The posterior pararenal space(PPS) is a potential space between the posterior renal fascia and the transversalis fascia. We reviewed 12 cases of posterior pararenal effusion. The causes of the effusion were retroperitoneal hemorrhage due to trauma(7 cases) or rupture of renal tumor(1 case), pancreatitis(2 cases), urinoma (1 case) and amebic colitis of the cecum(1 case). The CT findings of the effusion were semilunar fluid density in the dependant portion of the PPS(9/12), partial obliteration of the PPS extending to the flank stripe(2/12), and total obliteration of the PPS extending to the anterior abdominal wall(1/12). The effusion in the ipsilateral perirenal space and thickening of the ipsilateral posterior renal fascia were combined in all cases. The effusion in the ipsilateral anterior pararenal space was associated in 11 cases of 12. The effusion in the PPS is not uncommon findings of retroperitoneal hemorrhage or effusion, but usually related with perirenal or anterior pararenal effusion with no clinical significance

  15. No difference in gait between posterior cruciate retention and the posterior stabilized design after total knee arthroplasty

    NARCIS (Netherlands)

    van den Boom, Lennard G. H.; Halbertsma, Jan P. K.; van Raaij, Jos J. A. M.; Brouwer, Reinoud W.; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge

    2014-01-01

    In the present study, knee joint kinematics (e.g. knee flexion/extension) and kinetics (e.g. knee flexion moments) are assessed after total knee arthroplasty (TKA) between patients implanted with either a unilateral posterior stabilized (PS) and a posterior cruciate-retaining (PCR) design. It was

  16. Posterior distributions for likelihood ratios in forensic science.

    Science.gov (United States)

    van den Hout, Ardo; Alberink, Ivo

    2016-09-01

    Evaluation of evidence in forensic science is discussed using posterior distributions for likelihood ratios. Instead of eliminating the uncertainty by integrating (Bayes factor) or by conditioning on parameter values, uncertainty in the likelihood ratio is retained by parameter uncertainty derived from posterior distributions. A posterior distribution for a likelihood ratio can be summarised by the median and credible intervals. Using the posterior mean of the distribution is not recommended. An analysis of forensic data for body height estimation is undertaken. The posterior likelihood approach has been criticised both theoretically and with respect to applicability. This paper addresses the latter and illustrates an interesting application area. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  17. The distal semimembranosus complex: normal MR anatomy, variants, biomechanics and pathology

    International Nuclear Information System (INIS)

    Beltran, Javier; Jbara, Marlena; Maimon, Ron; Matityahu, Amir; Hwang, Ki; Padron, Mario; Mota, Javier; Beltran, Luis; Sundaram, Murali

    2003-01-01

    To describe the normal MR anatomy and variations of the distal semimembranosus tendinous arms and the posterior oblique ligament as seen in the three orthogonal planes, to review the biomechanics of this complex and to illustrate pathologic examples. The distal semimembranosus tendon divides into five tendinous arms named the anterior, direct, capsular, inferior and the oblique popliteal ligament. These arms intertwine with the branches of the posterior oblique ligament in the posterior medial aspect of the knee, providing stability. This tendon-ligamentous complex also acts synergistically with the popliteus muscle and actively pulls the posterior horn of the medial meniscus during knee flexion. Pathologic conditions involving this complex include complete and partial tears, insertional tendinosis, avulsion fractures and bursitis. (orig.)

  18. The distal semimembranosus complex: normal MR anatomy, variants, biomechanics and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, Javier; Jbara, Marlena; Maimon, Ron [Department of Radiology, Maimonides Medical Center, 4802 Tenth Avenue, NY 11219, Brooklyn (United States); Matityahu, Amir; Hwang, Ki [Department of Orthopedic Surgery, Maimonides Medical Center, Brooklyn, NY (United States); Padron, Mario [Department of Radiology, Clinica CEMTRO, Madrid (Spain); Mota, Javier [Department of Radiology, Instituto Clinica Corachan, Barcelona (Spain); Beltran, Luis [New York Medical College, Valhalla, NY (United States); Sundaram, Murali [Department of Radiology, Mayo Clinic, Rochester, MN (United States)

    2003-08-01

    To describe the normal MR anatomy and variations of the distal semimembranosus tendinous arms and the posterior oblique ligament as seen in the three orthogonal planes, to review the biomechanics of this complex and to illustrate pathologic examples. The distal semimembranosus tendon divides into five tendinous arms named the anterior, direct, capsular, inferior and the oblique popliteal ligament. These arms intertwine with the branches of the posterior oblique ligament in the posterior medial aspect of the knee, providing stability. This tendon-ligamentous complex also acts synergistically with the popliteus muscle and actively pulls the posterior horn of the medial meniscus during knee flexion. Pathologic conditions involving this complex include complete and partial tears, insertional tendinosis, avulsion fractures and bursitis. (orig.)

  19. MRI evaluation of the posterior meniscus root tear

    International Nuclear Information System (INIS)

    Zhang Jianjun; Zheng Zhuozhao; Li Xuan

    2010-01-01

    Objective: To determine the value of MRI for diagnosing the posterior meniscus root tear. Methods: MR examinations of 30 patients with tear of the posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. Of the 30 patients, 17 with posterior medial meniscus root tear (MMRT) and 13 with posterior lateral meniscus root tear (LMRT). The diagnostic sensitivity of' MRI for the posterior meniscus root tear was analyzed. Fisher's exact test was used to compare the detection rate of MRI for MMRT with that for LMRT. Results: All 17 cases with MMRT and 9 cases out of 13 with LMRT were correctly diagnosed by MRI and the diagnostic sensitivity of MRI for the posterior meniscus root tear was 86.7% (26/30). The main MR appearance of the posterior meniscus root tear was distortion of the meniscal root, with its low signal replaced by abnormal high signal. The detection rate of MRI for MMRT (17/17) was significantly greater than that for LMRT (9/13) (P=0.026). The prevalence of MMRT associated with meniscus extrusion (15/17) was significantly greater than that of LMRT (6/13) (P=0.020), but the prevalence of MMRT associated with anterior cruciate ligament (ACL) injury (5/17) was significantly lower than that of LMRT (11/13) (P=0.004). Conclusion: MRI is a relatively good method for detection of posterior meniscus root tears and associated injuries. (authors)

  20. Variations of posterior vitreous detachment

    OpenAIRE

    Kakehashi, A.; Kado, M.; Akiba, J.; Hirokawa, H.

    1997-01-01

    AIMS—To identify variations in posterior vitreous detachment (PVD) and establish a clinical classification system for PVD.
METHODS—400 consecutive eyes were examined using biomicroscopy and vitreous photography and classified the PVD variations—complete PVD with collapse, complete PVD without collapse, partial PVD with thickened posterior vitreous cortex (TPVC), or partial PVD without TPVC.
RESULTS—In each PVD type, the most frequently seen ocular pathologies were as follows: in complete PVD ...

  1. Campylobacter jejuni cocultured with epithelial cells reduces surface capsular polysaccharide expression.

    LENUS (Irish Health Repository)

    Corcionivoschi, N

    2012-02-01

    The host cell environment can alter bacterial pathogenicity. We employed a combination of cellular and molecular techniques to study the expression of Campylobacter jejuni polysaccharides cocultured with HCT-8 epithelial cells. After two passages, the amount of membrane-bound high-molecular-weight polysaccharide was considerably reduced. Microarray profiling confirmed significant downregulation of capsular polysaccharide (CPS) locus genes. Experiments using conditioned media showed that sugar depletion occurred only when the bacterial and epithelial cells were cocultured. CPS depletion occurred when C. jejuni organisms were exposed to conditioned media from a different C. jejuni strain but not when exposed to conditioned media from other bacterial species. Proteinase K or heat treatment of conditioned media under coculture conditions abrogated the effect on the sugars, as did formaldehyde fixation and cycloheximide treatment of host cells or chloramphenicol treatment of the bacteria. However, sugar depletion was not affected in flagellar export (fliQ) and quorum-sensing (luxS) gene mutants. Passaged C. jejuni showed reduced invasiveness and increased serum sensitivity in vitro. C. jejuni alters its surface polysaccharides when cocultured with epithelial cells, suggesting the existence of a cross talk mechanism that modulates CPS expression during infection.

  2. Effects of light wavelengths on extracellular and capsular polysaccharide production by Nostoc flagelliforme.

    Science.gov (United States)

    Han, Pei-pei; Sun, Ying; Jia, Shi-ru; Zhong, Cheng; Tan, Zhi-lei

    2014-05-25

    The influences of different wavelengths of light (red 660nm, yellow 590nm, green 520nm, blue 460nm, purple 400nm) and white light on extracellular polysaccharide (EPS) and capsular polysaccharide (CPS) production by Nostoc flagelliforme in liquid culture were demonstrated in this study. The results showed that, compared with white light, red and blue lights significantly increased both EPS and CPS production while yellow light reduced their production; purple and green lights stimulated EPS production but inhibited CPS formation. Nine constituent monosaccharides and one uronic acid were detected in both EPS and CPS, and their ratios showed significant differences among treatment with different light wavelengths. However, the advanced structure of EPS and CPS from various light conditions did not present obvious difference through Fourier transform infrared spectroscopy and X-ray diffraction characterization. These findings establish a basis for development of high-yielding polysaccharide production process and understanding their regulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  4. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  5. Abordagem cirúrgica posterior e posterolateral para neurinomas cervicais em ampulheta da raiz de C2 Posterior y posterolateral enfoque quirúrgico para los neurinomas de la raíz cervical C2 Posterior and posterior-lateral surgical approach for C2 hourglass-shaped cervical neurinomas

    Directory of Open Access Journals (Sweden)

    Asdrubal Falavigna

    2010-06-01

    Full Text Available OBJETIVO: os autores relatam a experiência cirúrgica de 11 neurinomas em ampulheta de C2 comparando à via de acesso posterior com a posterolateral. MÉTODOS: onze pacientes com neurinomas em ampulheta de raiz cervical de C2 foram tratados cirurgicamente. A via de acesso utilizada para a remoção dos tumores foi a abordagem posterior em sete pacientes, e a posterolateral em quatro pacientes. RESULTADOS: houve predominância do sexo feminino (n=6 e a média de idade foi de 55,9±8,16 anos. O tempo médio de sintoma até o diagnóstico foi de 16,3 meses (±8,02 meses. Houve ressecção completa do tumor em todos os pacientes. O tempo cirúrgico médio na abordagem posterior foi de 180 minutos (±39,15 e de 192 minutos (±22,17 pela via posterolateral (p=0,52. Não houve diferença estatisticamente significativa entre as abordagens em relação ao sangramento transoperatório (posterior: 70,71±16,93; posterolateral: 65,00±24,15; p=0,64. Ocorreu uma complicação com a via de acesso posterior ligada à presença de uma fístula de líquor, sendo necessária nova intervenção e reconstrução da dura-máter utilizando a fáscia lata. CONCLUSÃO: a retirada completa do tumor em ampulheta da raiz de C2 é possível através das abordagens posterior e posterolateral, entretanto, a abordagem posterior é preferível por ser a via de acesso mais familiar ao cirurgião.OBJETIVO: os autores describen la experiencia quirúrgica de 11 neurinomas en reloj de arena de la raíz de C2 comparando el camino de acceso posterior y el postero-lateral. MÉTODOS: se trataron con cirugía 11 pacientes con neurinoma en reloj de arena de raíz cervical de C2. El camino de acceso utilizado para la retirada de los tumores fue la aproximación posterior en siete pacientes, y la aproximación postero-lateral, en 4. RESULTADOS: hubo predominio del sexo femenino (n=6, siendo la edad promedio de 55,9 ± 8,16 años. El tiempo medio de los síntomas hasta su diagnóstico fue

  6. 1st oPAC Topical Workshop: Grand Challenges in Accelerator Optimisation

    CERN Document Server

    2013-01-01

    Accelerators are key instruments for fundamental research, health and industry applications. International collaboration is very important for their continued optimisation. To address this oPAC is organising this two-day international workshop on Grand Challenges in Accelerator Optimisation. The workshop will provide an overview of the current state of the art in beam physics, numerical simulations and beam instrumentation and highlight existing limitations. It will discuss research and development being undertaken and ambitions to further improve the performance of existing and future facilities. In addition to invited talks, there will be industry displays and a special seminar covering recent LHC discoveries. All participants will have an opportunity to contribute a poster.

  7. Posterior Urethroplasty Complexity and Prognosis Can be Described by a Novel Method: Posterior Urethral Stenosis Score.

    Science.gov (United States)

    Wang, Lin; Lv, Xiangguo; Jin, Chongrui; Guo, Hailin; Shu, Huiquan; Fu, Qiang; Sa, Yinglong

    2018-02-01

    To develop a standardized PU-score (posterior urethral stenosis score), with the goal of using this scoring system as a preliminary predictor of surgical complexity and prognosis of posterior urethral stenosis. We retrospectively reviewed records of all patients who underwent posterior urethral surgery at our institution from 2013 to 2015. The PU-score is based on 5 components, namely etiology (1 or 2 points), location (1-3 points), length (1-3 points), urethral fistula (1 or 2 points), and posterior urethral false passage (1 point). We calculated the score of all patients and analyzed its association with surgical complexity, stenosis recurrence, intraoperative blood loss, erectile dysfunction, and urinary incontinence. There were 144 patients who underwent low complexity urethral surgery (direct vision internal urethrotomy, anastomosis with or without crural separation) with a mean score of 5.1 points, whereas 143 underwent high complexity urethroplasty (anastomosis with inferior pubectomy or urethrorectal fistula repair, perineal or scrotum skin flap urethroplasty, bladder flap urethroplasty) with a mean score of 6.9 points. The increase of PU-score was predictive of higher surgical complexity (P = .000), higher recurrence (P = .002), more intraoperative blood loss (P = .000), and decrease of preoperative (P = .037) or postoperative erectile function (P = .047). However, no association was observed between PU-score and urinary incontinence (P = .213). The PU-score is a novel and meaningful scoring system that describes the essential factors in determining the complexity and prognosis for posterior urethral stenosis. Copyright © 2017. Published by Elsevier Inc.

  8. Structural studies of some bacterial capsular polysaccharides from the family enterobacteriaceae: Klebsiella serotypes K79 and K35 and Escherichia coli serotype K44

    Energy Technology Data Exchange (ETDEWEB)

    Lim, A.V.S.

    1986-01-01

    The techniques of sugar analysis, methylation, chromic acid oxidation, deamination, base-catalyzed uronic acid degradation, Smith degradation and partial hydrolysis were used in the structural elucidation of bacterial capsular polysaccharides. Methods such as gas-liquid chromatography, gas chromatography-mass spectrometry, gel permeation, ion-exchange and paper-chromatography were used to isolate and characterize oligosaccharides obtained from degradative procedures. N.m.r. spectroscopy (/sup 1/H and /sup 13/C) was widely used in the characterization of the polysaccharides and of derived poly- and oligo-saccharides. In a few instances, n.m.r. spectroscopy and mass spectrometry were used to delineate the sequence of the sugars in the structure of the poly- and oligo-saccharides. The bacteriophage-induced depolymerizations of the capsular polysaccharides of Klebsiella K79 and E. coli K44 are also reported in this thesis. The sum of these experiments demonstrated that the endoglycanase associated with Klebsiella Phi 79 had ..beta..-galactosidase activity. The endoglycanase from E. coli Phi 44 exhibited ..beta..-N-acetyl-galactosaminidase activity which is novel, in that it is the first reported action of this nature in the bacteriophages isolated for the species E. coli.

  9. Actividad diferencial de fagocitosis e inducción de apoptosis in vitro por serotipos capsulares 5 y 8 de Staphylococcus aureus en neutrófilos de bovinos

    Directory of Open Access Journals (Sweden)

    Nancy Montoya García

    2015-01-01

    Full Text Available Se evaluó la actividad de fagocitosis y apoptosis in vitro en leucocitos polimorfonucleares (PMN de bovinos lecheros frente a Staphylococcus aureus tipos capsulares 5 y 8. Los neutrófilos se obtuvieron de vacas clínicamente sanas. La actividad de fagocitosis de neutrófilos se determinó a partir de la capacidad e índice de fagocitosis. La evaluación de la apoptosis se realizó por microscopía de campo claro (ML y de epifluorescencia (MF. Se observaron diferencias entre los tratamientos en ML para la capacidad de fagocitosis, el tipo compacto (CC fue 86.50±2.93, serotipo capsular 5 (CP5 74.98±2.44 y serotipo capsular 8 (CP8 82.22±1.5 ( P <0.05. Los valores para el índice de fagocitosis fueron: CC 6.13±0.31, CP5 4.88±0.13 y CP8 5.22±0.10 ( P <0.05. La capacidad de fagocitosis observada en la MF fue: CC 86.77±2.6, CP5 62.52±3.26 y CP8 78.60±4.07. El índice de fagocitosis para la CC fue de 7.62±0.55, 4.67±0.29 para CP5 y de 5.53±0.40 para CP8 ( P <0.05. Los porcentajes de apoptosis por ML fueron: testigo positivo (C+ 97.7±1.28, testigo negativo (C- 27.13±1.85, CC 35.44±2.56, CP5 60.07±4.21 y CP8 45.57±4.34 ( P <0.05. En la técnica de MF fueron: C(+ 95.61±2.66, C(- 20.2±1.77, CC 26.5±1.65, CP5 52.78±3.29 y CP8 41.33±2.32 ( P <0.05. Se encontraron diferencias en la capacidad e índice de fagocitosis y apoptosis de los PMN entre los tipos capsulares de S. aureus evaluados. El CP5 al reducir la actividad de fagocitosis e incrementar la inducción de la apoptosis en los neutrófilos, puede contribuir a la persistencia de la infección intraglandular mamaria del ganado lechero en la mastitis bovina.

  10. STUDY TO EVALUATE THE ADDITIONAL BENEFIT OF THE HYDROLIC CAPSULAR DISTENTION USING NORMAL SALINE AND STEROID IN THE MANAGEMENT OF THE FROZEN SHOULDERS TREATED WITH CONVENTIONAL PHYSIOTHERAPY

    Directory of Open Access Journals (Sweden)

    Mandar S

    2015-02-01

    Full Text Available Although many treatment options have been advocated for the self - limiting disease of the frozen shoulder, there is no robust evidence of the superiority of one over other . This study intended to evaluate the outcome of hydrolic capsular distension followed by physiotherapy and its comparison with only physiotherapy regime in treatment of frozen shoulder. AIMS AND OBJECTIVES : Evaluate the additional benefit of the hydrolic capsular distension using normal saline and steroid in the management of the frozen shoulder treated with conventional physiotherapy . MATERIALS AND METHODS: In this randomized prospective study we have studied total 50 cases within the age group of 40 - 70 years with idiopathic frozen shoulder. They were divided into two groups of 25 patients each. Patients in the first group were treated with shoulder joint capsular distension using normal saline and steroid under local anesthesia at outpatient department followed by physiotherapy and the patients in second group were treated with physiotherapy only. The aim was to obtain earlier pain relief and earlier relief from functional disability. Shoulder pain and disability index (SPADI & Visual analogue scale (VAS score was used as a tool for evaluation and comparison. RESULTS: After confounding all the demographic factors it was found that the intra as well as inter group change in SPADI score revealed statistically extremely significant difference (p value - <0.0001 at the end of 12 th week. Hydrotherapy group being superior than the only physiotherapy group. VAS score showed statistically extremely significant improvement in hydrotherapy group at the end of 1 st week (p value - <0.0001 as compared to not much improvement in only physiotherapy group (p value - 0.0830. Similar results were observed with the SPADI score values at the end of first week, where 80% patient in hydrotherapy group felt some improvement in performing daily activities at the same time no one was quoted

  11. Early endoscopic realignment in posterior urethral injuries.

    Science.gov (United States)

    Shrestha, B; Baidya, J L

    2013-01-01

    Posterior urethral injury requires meticulous tertiary care and optimum expertise to manage successfully. The aim of our study is to describe our experiences with pelvic injuries involving posterior urethra and their outcome after early endoscopic realignment. A prospective study was carried out in 20 patients with complete posterior urethral rupture, from November 2007 till October 2010. They presented with blunt traumatic pelvic fracture and underwent primary realignment of posterior urethra in our institute. The definitive diagnosis of urethral rupture was made after retrograde urethrography and antegrade urethrography where applicable. The initial management was suprapubic catheter insertion after primary trauma management in casualty. After a week of conservative management with intravenous antibiotics and pain management, patients were subjected to the endoscopic realignment. The follow up period was at least six months. The results were analyzed with SPSS software. After endoscopic realignment, all patients were advised CISC for the initial 3 months. All patients voided well after three months of CISC. However, 12 patients were lost to follow up by the end of 6 postoperative months. Out of eight remaining patients, two had features of restricture and were managed with DVU followed by CISC again. One patient with restricture had some degree of erectile dysfunction who improved significantly after phospodiesterase inhibitors. None of the patients had features of incontinence. Early endoscopic realignment of posterior urethra is a minimally invasive modality in the management of complete posterior urethral injury with low rates of incontinence and impotency.

  12. The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).

    Science.gov (United States)

    Mauschitz, Matthias M; Roth, Felix; Holz, Frank G; Breteler, Monique M B; Finger, Robert P

    2017-05-01

    To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL). RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity. Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.

  13. Relaxing the Small Particle Approximation for Dust-grain opacities in Carbon-star Wind Models

    OpenAIRE

    Mattsson, Lars; Höfner, Susanne

    2010-01-01

    We have computed wind models with time-dependent dust formation and grain-size dependent opacities, where (1) the problem is simplified by assuming a fixed dust-grain size, and where (2) the radiation pressure efficiency is approximated using grain sizes based on various means of the actual grain size distribution. It is shown that in critical cases, the effect of grain sizes can be significant. For well-developed winds, however, the effects on the mass-loss rate and the wind speed are small.

  14. Phenotype-genotype correlation in potential female carriers of X-linked developmental cataract (Nance-Horan syndrome).

    Science.gov (United States)

    Khan, Arif O; Aldahmesh, Mohammed A; Mohamed, Jawahir Y; Alkuraya, Fowzan S

    2012-06-01

    To correlate clinical examination with underlying genotype in asymptomatic females who are potential carriers of X-linked developmental cataract (Nance-Horan syndrome). An ophthalmologist blind to the pedigree performed comprehensive ophthalmic examination for 16 available family members (two affected and six asymptomatic females, five affected and three asymptomatic males). Facial features were also noted. Venous blood was collected for sequencing of the gene NHS. All seven affected family members had congenital or infantile cataract and facial dysmorphism (long face, bulbous nose, abnormal dentition). The six asymptomatic females ranged in age from 4-35 years old. Four had posterior Y-suture centered lens opacities; these four also exhibited the facial dysmorphism of the seven affected family members. The fifth asymptomatic girl had scattered fine punctate lens opacities (not centered on the Y-suture) while the sixth had clear lenses, and neither exhibited the facial dysmorphism. A novel NHS mutation (p.Lys744AsnfsX15 [c.2232delG]) was found in the seven patients with congenital or infantile cataract. This mutation was also present in the four asymptomatic girls with Y-centered lens opacities but not in the other two asymptomatic girls or in the three asymptomatic males (who had clear lenses). Lens opacities centered around the posterior Y-suture in the context of certain facial features were sensitive and specific clinical signs of carrier status for NHS mutation in asymptomatic females. Lens opacities that did not have this characteristic morphology in a suspected female carrier were not a carrier sign, even in the context of her affected family members.

  15. Atividade lenta posterior: correlação eletro-clínica Posterior EEG slow activity: electro-clinical correlation

    Directory of Open Access Journals (Sweden)

    Salustiano Gomes Lins

    1971-06-01

    Full Text Available Inicialmente é feita breve exposição dos cinco principais tipos de atividade lenta posterior descritas na literatura eletrencefalográfica: variedade lenta do ritmo alfa, ritmo theta posterior, ondas lentas posteriores a 4 hertz, ritmo delta associado ao pequeno mal e ondas Pi. Em seguida o autor expõe seus achados, baseado num material clínico composto por 760 pacientes, colhidos ao acaso, dos dois sexos e com idades variáveis entre 5 e 24 anos. Excetuando a variedade lenta do ritmo alfa, um ou mais dos outros quatro grafo-elementos referidos foram observados em 131 destes pacientes (80 do sexo masculino e 51 do sexo feminino pertencentes aos 3 primeiros grupos etários (5 a 19 anos. Sua predominância no sexo masculino não alcançou nível de significação estatística, mas a maior incidência nos grupos de menor idade foi significativa a 0,01. O ritmo theta posterior associou-se significativamente apenas a distúrbios de conduta com forte agressividade. Dos 131 casos referidos, 10 eram portadores de pequeno mal e destes, 5 apresentavam ritmo delta posterior (3 do sexo masculino e 2 do sexo feminino. Apenas em dois casos foi observado o ritmo lento posterior a 4 hertz, ambos com comemorativos de traumatismo craniano, seguido de distúrbios da conduta e agressividade.The five principal types of posterior slow activity are reviwed: the slow alpha variant rhythm; the posterior theta rhythm; the posterior slow waves at 4 c/s; the delta rhythm associated with petit mal; the so called Pi waves. The results with EEG tracings of 760 patients of both sexes with ages between 5 and 24 years are reviewed. Except for the slow alpha variant, at least one of the four other phenomena as observed in 131 patients (80 males end 51 females. The theta rhythm was observed in 49 cases (29 males and 20 females. This higher frequence among the males is not significant but the higher frequence among the younger and the association with a clinical picture of

  16. Ophthalmologic abnormalities among deaf students in Kaduna ...

    African Journals Online (AJOL)

    Annals of African Medicine. Vol. ... Medicine, Harvard University, U.S.A. ... abnormalities such as corneal opacities (0.5%) and allergic conjunctivitis (3.4%) while others had posterior .... were administered to those with treatable eye disease.

  17. Effects of Silicone Hydrogel Contact Lens Application on Corneal High-order Aberration and Visual Guality in Patients with Corneal Opacities

    Directory of Open Access Journals (Sweden)

    Sevda Aydın Kurna

    2012-03-01

    Full Text Available Pur po se: Evaluation of the corneal high-order aberrations and visual quality changes after application of silicone hydrogel contact lenses in patients with corneal opacities due to various etiologies. Ma te ri al and Met hod: Fifteen eyes of 13 patients with corneal opacities were included in the study. During the ophthalmologic examination before and after contact lens application, visual acuity was measured with Snellen acuity chart and contrast sensitivity - with Bailey-Lowie Charts in letters. Aberrations were measured with corneal aberrometer (NIDEK Magellan Mapper under a naturally dilated pupil. Spherical aberration, coma, trefoil, irregular astigmatism and total high-order root mean square (RMS values were recorded. Measurements were repeated with balafilcon A lenses (PureVision 2 HD, B&L on all patients. Re sults: Patient age varied between 23 and 50 years. Two eyes had subepithelial infiltrates due to adenoviral keratitis, 1 had nebulae due to previous infections or trauma, and 2 had Salzmann’s nodular degeneration. We observed a mean increase of 1 line in visual acuity and 5 letters in contrast sensitivity with contact lenses versus glasses in the patients. Mean RMS values of spherical aberration, irregular astigmatism and total high-order aberrations decreased significantly with contact lenses. Dis cus si on: Silicone hydrogel soft contact lenses may improve visual quality by decreasing the corneal aberrations in patients with corneal opacities. (Turk J Ophthalmol 2012; 42: 97-102

  18. Opacity calculations and Saha's equation for high Z elements

    International Nuclear Information System (INIS)

    Godwal, B.K.; Sikka, S.K.

    1977-01-01

    Opacity calculations are needed for energy transport by radiation for high Z element plasmas as these have been suggested as temper materials in laser, electron beam and heavy ion fusion schemes. The pressure ionised modified form of Saha's ionisation equation has been used to obtain the free electron density, populations of various ionic species and the populations of various energy states for a given ion. Results are presented for two typical elements; tungsten and uranium. The ionisation potential have been evaluated using the Bohr's formula with suitable effective screened charges for ions. The results show that for uranium, even at a temperature of 10 kev, the K shell is intact. The reliability of the Saha's equation solution has been checked by comparing the equation of state (total pressure vs total energy curve) with that given by the Thomas-Fermi-Dirac equation of state. The agreement between the two is good from temperature upwards of 0.2 kev. (author)

  19. Selective posterior lumbosacral rhizotomy for the management ...

    African Journals Online (AJOL)

    tion in 95% of cases. The majority showed ... selective posterior rhizotomy technique whereby the cauda equina ... assessed pre- and postoperatively by means of clinical examination ... were attending cerebral palsy schools and receiving spe- cialised ... root sections on cats demonstrated clearly that posterior root section ...

  20. Possibly Ill-behaved Posteriors in Econometric Models

    NARCIS (Netherlands)

    L.F. Hoogerheide (Lennart); H.K. van Dijk (Herman)

    2008-01-01

    textabstractHighly non-elliptical posterior distributions may occur in several econometric models, in particular, when the likelihood information is allowed to dominate and data information is weak. We explain the issue of highly non-elliptical posteriors in a model for the effect of education on