  1. Dosimetric study for characterization of a postal system of quality control in brachytherapy

    International Nuclear Information System (INIS)

    Alves, Victor Gabriel Leandro; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza; Begalli, Marcia

    2009-01-01

    This work presents a dosimetric study of a postal system, to be developed for measurements of brachytherapy. It was projected a PMMA phantom with orifices for insertion of the high dose 192 Ir source and the T L dosemeters. The system was characterized with using of Monte Carlo simulations, using the dosimetric magnitudes defined at the T G-43 of AAPM, as function of radial dose g(f)

  2. Dosimetric study for characterization of a postal system of quality control in brachytherapy; Estudo dosimetrico para caracterizacao de um sistema postal de controle de qualidade em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Victor Gabriel Leandro, E-mail: vgalves@inca.gov.b [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil); Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza, E-mail: queiroz@ird.gov.b, E-mail: santosd@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Begalli, Marcia, E-mail: begalli@uerj.b [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica

    2009-07-01

    This work presents a dosimetric study of a postal system, to be developed for measurements of brachytherapy. It was projected a PMMA phantom with orifices for insertion of the high dose {sup 192}Ir source and the T L dosemeters. The system was characterized with using of Monte Carlo simulations, using the dosimetric magnitudes defined at the T G-43 of AAPM, as function of radial dose g(f)

  3. Layers And Processes In The Model Of Technological Postal System

    Directory of Open Access Journals (Sweden)

    Madleňáková Lucia

    2015-12-01

    Full Text Available The paper include important aspects of layer model of postal technological system such as makes the possibility to define rules for regulating, technical and technological requirements and interfaces to communicate with other postal systems. The current postal reform is mainly attributable to release of network access and ensuring full interoperability between technological systems. Not only to ensure the development and protection of competition but also in respect to the conservation of requirements to provide the universal service, which is the performance of public interest. There is a space here to examine the postal system, not only from a procedural point of view, but to be viewed as an open communication system. It is possible to find there the commonalities with other communication sector branches and to handle the technological postal system in more layers; similarly as the electronic communication systems are handled. Model of layer postal system, based not only on the processes but on layers functionality, will enable to identify communication protocols and interfaces determining interoperability. It also opens the question of appropriate regulation model.

  4. Dosimetric system for measurement of radioactive contaminations

    International Nuclear Information System (INIS)

    Litynski, Z.; Pienkos, J.P.; Witkowski, J.; Zadrozny, S.

    1985-01-01

    A dosimetric system for personnel dosimetry and monitoring measuring a contamination without time delay and dead time is described. The system ensures many-point measurement and minimalization of background radiation influence. 1 fig. (A.S.)

  5. Experiences on the implementation of a postal auditing service to know teletherapy doses using Cobalt 60 attained by the Secondary laboratory for dosimetric calibration from CPHR

    International Nuclear Information System (INIS)

    Campa, R.; Morales, J.A.; Molina, D.; Dominguez, L.

    1998-01-01

    This paper analyzes experiences gained by LSCD from CPHR on the implementation and validation of a postal auditing system. The system checks doses absorbed by water for teletherapy equipment using Cobalt 60. The verification was made with Chinese DTL type JR 1152F (microbars) introduced in capsules developed and employed by IAEA in the postal auditing service for doses IAEA/WHO. The analysis includes the creation of groups of detectors based on their individual sensibility. They have a dispersion range that was almost 2%. Here irradiation was applied to a water dummy. Other tests employed were that for thermal treatment and calibration. Besides one auditing the effectiveness of the postal technique in two facilities using Cobalt 60. The methodology implemented helps to determine doses absorbed in reference conditions with a lower global uncertainty (k=2) (3.2%)

  6. Dosimetric system for prolonged manned flights

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Kovalev, E.E.; Sakovich, V.A.; Deme, Sh.; Fekher, I.; Nguen, V.D.

    1991-01-01

    Comments for the All-Union state standard 25645.202-83 named Radiation safety of a spacecraft crew during space flight. Requirements for personnel dosimetric control, are given. Devices for the dosimetric control used in manned space flights nowadays are reviewed. The performance principle and structure of the FEDOR dosimetric complex under development are discussed

  7. Managment of electronic services of the Serbian postal system by benchmarking index

    Directory of Open Access Journals (Sweden)

    Dupljanin Đorđije D.

    2014-01-01

    Full Text Available The aim of this paper is analys of the state of electronic services within the postal system in Serbia in order to improve the management of this services. As an indicator of the state of development we can use benchmarking index of development of postal e-services. Benchmarking index is created by PCA (Principal Component Analysis method in statistical software Minitab which has been designed for PCA. The development of electronic economy has influence on postal system to improve postal electronic services. In conclusion we can say those who make the decisions and management experts have to define appropriate strategy of e-services.

  8. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  9. Chilean Nuclear Energy Commission dosimetric information system

    International Nuclear Information System (INIS)

    Guerrero Vallejos, Patricia Andrea

    1997-01-01

    This thesis discusses the nuclear radiation that people who work with radioactive material is exposed to and its control by the Chilean Nuclear Energy Commission. A full analysis of the System is presented with information about the Commission and the Department of Nuclear and Radiological Safety which runs the System. Ana analysis of the System is presented in order to obtain requirements. Management flow diagrams, the processes involved and current problems experienced by the users are described. A design logic is modeled producing Data Flow Diagrams (DFD). based on this physical design, or, Model of Physical Data, is prepared including tables, attributes, types of data, primary and foreign keys. A description is presented of how the System is implemented, the tools that are used and how the testing phase is carried out. The Dosimetry System meets the criteria for a Software Engineering project, where the basic cycle was used as a working methodology. The System developed supports the dosimetric control of people exposed to radioactive material. (author)

  10. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    International Nuclear Information System (INIS)

    Campos, Luciana Tourinho; Leite, Sandro Passos; Almeida, Carlos Eduardo Veloso de; Magalhães, Luís Alexandre Gonçalves

    2017-01-01

    Radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. The Radiological Science Laboratory (LCR/UERJ) operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy and the dosimetric conditions of the TPS. The programme works in such a way those TLDs are sent to the centre where they are to be irradiated to a certain dose. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data. (author)

  11. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Luciana Tourinho; Leite, Sandro Passos; Almeida, Carlos Eduardo Veloso de; Magalhães, Luís Alexandre Gonçalves, E-mail: tc_luciana@yahoo.com.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. The Radiological Science Laboratory (LCR/UERJ) operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy and the dosimetric conditions of the TPS. The programme works in such a way those TLDs are sent to the centre where they are to be irradiated to a certain dose. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data. (author)

  12. Computerized dosimetric system for studying radiation fields of afterloading apparatus

    International Nuclear Information System (INIS)

    Andryushin, O.S.; Gorshkov, M.I.

    1988-01-01

    Works on designing a computerized dosimetric scanner (CODOS) for studying radiation fields of remote therapeutic apparatus, providing dosimetric data input from semiconductor transducers and ionization chambers directly into the computer memory were carried out. The basic problems were to provide reproducibility and accuracy of the initial dosimetric data, formation of the data bank on LUEhV-15M1 accelerator bremsstrahlung and electron radiation fields. An extra problem was to provide isodose curves for manual scheduling of radiotherapy. The 15 VUMS-28-025 complex based on Elektronika-60 computer was chosen as a host computer, photodiodes were used as a semiconductor detector, the 70108 rod chamber and VA-J-18 dosemeters were used as an ionization chamber. The results of studies with the CODOS system have been shown that it meets the dosimetric requirements for therapeutic apparatus

  13. Implementation of Itella mail Logistics System in Ghana Postal Services

    OpenAIRE

    Tetteh, Richard

    2012-01-01

    Information technology is one of the major drivers of innovation, economic growth and social change. The emergence of Information and Communication Technology (ICT) has led to a paradigm shift in the Postal Services industry, where innovation has become a competitive tool in the logistics chain process. Unlike the traditional way of receiving, sorting and delivering letters by human, the modern real-time based practical approach brings the public faster and more reliable services. To resp...

  14. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Science.gov (United States)

    Campos, L. T.; Leite, S. P.; de Almeida, C. E. V.; Magalhães, L. A. G.

    2018-03-01

    Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.

  15. Study of a new dosimetric radio-thermoluminescent systems

    International Nuclear Information System (INIS)

    Cazac, T.C.

    1980-01-01

    This is the first Romanian study to investigate conditions to obtain the radio-thermo-luminescent systems: MgB 4 O 7 :A(A-Nd,Sm,Eu,Dy,Tb,Dy+Sm and Tb+Sm) MgF 2 A (A=Mn,Dy,Tb,Sm,Li), their essential dosimetric characters, as well as the (MgF 2 =Mn) thermophosphorus mixture with a ( 6 LiF) lithium target. An investigation was developed upon a new category of radio-thermoluminescent detectors with low radiation energy dependence and fading, magnesjum boride activated by several elements of the lanthanides class (Nd,Sm,Eu,Dy,Tb). A new radio-thermoluminescent dosimetric system with high sensitivity and moderate dependence on energy radiation - (Mnsup(2+)) manganese activated magnesium fluoride - was also studied. The author explored application of investigated detectors MgF 2 =Mn, MgB 4 O 7 =Dy and MgB 4 O 7 :Tb in neutron dosimetry in complex gamma-neutron fields. It is deemed that by using the dosimetric systems reported in the thesis in order to measure gamma, beta and neutron radiation doses, dosimetric control can be ensured both in professional dosimetry and in nuclear accident dosimetry, as well as in various basic and applicative investigations. A modest contribution is thus made towards achieving the national nuclear program through an extension of the thermophosphorus range with practical applications in nuclear radiation dosimetry. (author)

  16. Dosimetric quality of postal kit used for evaluation in IRD/CNEN of radiation protection parameters in dental radiology in the State of Rio de Janeiro; Qualidade dosimetrica do kit postal utilizado pelo IRD/CNEN para a avaliacao dos parametros de radioprotecao em radiologia odontologica no Estado do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Coutinho, Soray Abbud; Mota, Helvecio C; Dovales, Ana Cristina M [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil). Dept. de Fisica Medica

    2001-07-01

    This work shows the results of a comparison between the skin entrance doses determined using an ionization chamber or a postal kit routinely used for the evaluation of radiation protection parameters in dental radiology in the state of Rio de Janeiro. By using the dosimetric kit, entrance skin dose is determined from two thermoluminescent dosimeters (TLDs) - previously calibrated in a {sup 137} Cs source - by using calibration factors determined in TLDs irradiated in air, on a water phantom and on an aluminium filter. The correspondence between the doses obtained with different methods was evaluated for three different X-ray spectra as radiation source. Results indicate that calibration factors used are adequate and that the kit has enough sensibility and reproducibility, measuring properly the skin entrance dose in dental X-rays. (author)

  17. On the set up of a thermoluminescent dosimetric system

    International Nuclear Information System (INIS)

    Furetta, C.

    2000-01-01

    In this work are treated the following features: Introduction to the thermoluminescent dosimetric systems, their prerequisites, Initialisation procedure, Batch homogeneity, Procedure for batch homogeneity (IEC), Reference and field dosimeters, Thermal treatments and its general considerations, as well as its initialisation treatment, erasing treatment or standard annealing (also called pre-irradiation annealing), post-irradiation or pre-readout annealing. Also is presented the performance of the annealing study, with its suggested procedures such as: a first and second procedures. Finally, it is showed about experimental data of the annealing treatments and its diagrams. (Author)

  18. 39 CFR 601.104 - Postal purchasing authority.

    Science.gov (United States)

    2010-07-01

    ... in writing local buying authority throughout the Postal Service. ... 39 Postal Service 1 2010-07-01 2010-07-01 false Postal purchasing authority. 601.104 Section 601.104 Postal Service UNITED STATES POSTAL SERVICE PROCUREMENT SYSTEM FOR THE U.S. POSTAL SERVICE...

  19. Quality control of dosimetric systems using thermoluminescent crystals

    International Nuclear Information System (INIS)

    Mahecha, L.; Plazas, M. C.; Machado, M.; Perea, M. D.

    2006-01-01

    To achieve an optimal tumoral control to prostate cancer in early and locally advanced stages, it is necessary to increase the dose with a low mobility probability at the vesicle an rectal level. This is achieved through conformal radiotherapy. The Instituto Nacional de Cancerologia uses this technique, but two questions arise from the medical-physicists and medical radio-oncologist: In accordance with clinical protocols, the conformal radiotherapy delivers a low dose to the adjacent healthy tissues. What experimental method exists that can prove with certainly the veracity of this affirmation?. And, Do the dosimetric simulation system calculate suitable the dose for each tissues?. Through thermoluminescent dosimetry and the use of a physical simulator,we measured the absorbed dose at the target volume and the adjacent tissues using conformal and conventional radiotherapy. We proved that organs such as the rectum and bladder, receiver a minor dose in conformal radiotherapy, hence reducing their mobility probability. In addition, the readings from the thermoluminescent dosimeters and the doses calculated by the ECLIPSE dosimetric system were compared, concluding that the patient's prescribed dose is effectively delivered as recommended by the quality control program in radiotherapy. (Author)

  20. Dosimetric commissioning of a CBCT system for IGRT purposes

    International Nuclear Information System (INIS)

    Alfonso, R.; Ascencion, Y.; Castillo, D.; Linares, H.; Argota, R.; Garcia, F.

    2015-01-01

    During the last few years the use of tomographic imaging systems based on kilo voltage, cone shaped photon beams (kV-CBCT) for ensuring an accurate positioning of patients in radiotherapy treatments has expanded to low income departments, such as those existing in public health systems of low and middle income countries (LMIC). Although several dosimetric studies have been published so far, showing results of collateral dose in patients exposed to kV-CBCT studies for image guidance radiotherapy purposes (IGRT), their main objective is to demonstrate that these doses are significantly lower than the prescribed dose to the target volume and even the dose to organs and healthy tissues. In the actual study a methodology is proposed to reduce the CBCT dose during IGRT procedures for tumor targets located in the thorax region, where motion management is crucial. Criteria for dose optimization, based on image quality indexes and automated positioning accuracy, were implemented. (Author)

  1. Postal audit in dental radiodiagnostics

    International Nuclear Information System (INIS)

    Novak, L.; Kroutilikova, D.

    2001-01-01

    According to Czech laws dental intraoral X-ray machines are classified as s imple sources of ionizing radiation . Consequently , their use is licensed on condition that an adequate quality assurance program is realized. In general, the programme is based on acceptance tests, status tests and constancy tests. The particular methods are specified in the recommendation [1] published by State Office for Nuclear Safety .Both the acceptance and status tests involve in situ measurements to control parameters of the X-ray machine and the developing process. Only persons who were licensed for such handling can do these measurements. The yearly status tests are very detailed and several years ' experience showed it might be advantageous to have a simpler method additionally available for purposes of the state supervision. Such a method is supposed as a postal audit. It should be simple enough to make the operation of the state supervision more effective but it also should provide sufficient information on radiation protection of the patients. Besides it should enable to prolong the period for the status tests ultimately .As for the postal audit, a small package containing a proper dosimetric set would be sent directly to the dentist who would treat it according to instructions. This paper describes such method that was developed in the National Radiation Protection Institute (NRPI) and results of pilot study that was carried out to test the method. The described method will be a helpful tool for the operation of the state supervision in the dental radiodiagnostics. The method will be implemented into the existing system of controls from 2002. Due to its simplicity and a quite rich content of information allows to check a big amount of the dental workplaces at once. It is supposed that one half of all Czech X-ray units will be checked in this way every year performed on state costs. It means 175 audits per month approximately. In this way, the operation of the quality

  2. Use of a dosimetric system using a SMT phototransistor in the measurement for some dosimetric parameters in conventional radiotherapy

    International Nuclear Information System (INIS)

    Silva, J.O. da; Magalhaes, C.M.S. de; Santos, L.A.P.

    2008-01-01

    For monitoring the delivered dose in the patient undergoing a cancer treatment with high-energy ionizing radiation beams is necessary to use appropriate dosimeters for the beam control quality and if it is possible, to obtain the dose information during the treatment. For this, semiconductor-based devices are used because of their high spatial resolution and to be easy to handle in spite of the ionization chambers. Nowadays the bipolar phototransistors are being proposed as ionizing radiation detectors for presenting, beyond these characteristics, the signal amplification factor (gain). So, the aim of this work is to present the use of a dosimetric system using a SMT phototransistor in the measurement for some dosimetric parameters in conventional radiotherapy: the field factor and the off-axis ratio. The phototransistors readings were compared with ones obtained from a PTW 23343 Markus chamber, under the same conditions. (author)

  3. [Connecting the Baltic area : the Swedish postal System in the seventeenth century] / Kaarel Vanamölder

    Index Scriptorium Estoniae

    Vanamölder, Kaarel, 1981-

    2011-01-01

    Arvustus: Connecting the Baltic area : the Swedish postal System in the seventeenth century. Ed. by Heiko Droste. Södertörn Studies in History, 9, Södertörn Academic Studies, 42 (Huddinge: Södertörns högskola, 2011)

  4. Analysis of uncertainties in the IAEA/WHO TLD postal dose audit system

    Energy Technology Data Exchange (ETDEWEB)

    Izewska, J. [Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Wagramer Strasse 5, Vienna (Austria)], E-mail: j.izewska@iaea.org; Hultqvist, M. [Department of Medical Radiation Physics, Karolinska Institute, Stockholm University, Stockholm (Sweden); Bera, P. [Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Wagramer Strasse 5, Vienna (Austria)

    2008-02-15

    The International Atomic Energy Agency (IAEA) and the World Health Organisation (WHO) operate the IAEA/WHO TLD postal dose audit programme. Thermoluminescence dosimeters (TLDs) are used as transfer devices in this programme. In the present work the uncertainties in the dose determination from TLD measurements have been evaluated. The analysis of uncertainties comprises uncertainties in the calibration coefficient of the TLD system and uncertainties in factors correcting for dose response non-linearity, fading of TL signal, energy response and influence of TLD holder. The individual uncertainties have been combined to estimate the total uncertainty in the dose evaluated from TLD measurements. The combined relative standard uncertainty in the dose determined from TLD measurements has been estimated to be 1.2% for irradiations with Co-60 {gamma}-rays and 1.6% for irradiations with high-energy X-rays. Results from irradiations by the Bureau international des poids et mesures (BIPM), Primary Standard Dosimetry Laboratories (PSDLs) and Secondary Standards Dosimetry Laboratories (SSDLs) compare favourably with the estimated uncertainties, whereas TLD results of radiotherapy centres show higher standard deviations than those derived theoretically.

  5. Quantitative dosimetric verification of an IMRT planning and delivery system

    International Nuclear Information System (INIS)

    Low, D.A.; Mutic, S.; Dempsey, J.F.; Gerber, R.L.; Bosch, W.R.; Perez, C.A.; Purdy, J.A.

    1998-01-01

    Background and purpose: The accuracy of dose calculation and delivery of a commercial serial tomotherapy treatment planning and delivery system (Peacock, NOMOS Corporation) was experimentally determined. Materials and methods: External beam fluence distributions were optimized and delivered to test treatment plan target volumes, including three with cylindrical targets with diameters ranging from 2.0 to 6.2 cm and lengths of 0.9 through 4.8 cm, one using three cylindrical targets and two using C-shaped targets surrounding a critical structure, each with different dose distribution optimization criteria. Computer overlays of film-measured and calculated planar dose distributions were used to assess the dose calculation and delivery spatial accuracy. A 0.125 cm 3 ionization chamber was used to conduct absolute point dosimetry verification. Thermoluminescent dosimetry chips, a small-volume ionization chamber and radiochromic film were used as independent checks of the ion chamber measurements. Results: Spatial localization accuracy was found to be better than ±2.0 mm in the transverse axes (with one exception of 3.0 mm) and ±1.5 mm in the longitudinal axis. Dosimetric verification using single slice delivery versions of the plans showed that the relative dose distribution was accurate to ±2% within and outside the target volumes (in high dose and low dose gradient regions) with a mean and standard deviation for all points of -0.05% and 1.1%, respectively. The absolute dose per monitor unit was found to vary by ±3.5% of the mean value due to the lack of consideration for leakage radiation and the limited scattered radiation integration in the dose calculation algorithm. To deliver the prescribed dose, adjustment of the monitor units by the measured ratio would be required. Conclusions: The treatment planning and delivery system offered suitably accurate spatial registration and dose delivery of serial tomotherapy generated dose distributions. The quantitative dose

  6. Study of dosimetric systems-ferrous sulfate-ferric sulfate, glass slides and dyed aqueous solutions

    International Nuclear Information System (INIS)

    Fernandes, L.

    1979-01-01

    The effect of some variables which can effect the preparation of the ferrous sulfate used as dosimetric solution has been studied. Among these variables the purity of the water used for the preparation of the solution and the presence (or absence) of oxygen in the dosimetric solution were considered. The dose rate distribution according to the transverse and longitudinal sections of the Co 60 irradiator was studied experimentally, using the dosimetric solution, and theoretically, using a computer program (KIFE). The results obtained with the ferrous sulface dosimetric solution were used as reference for the study of the application of EM and MSG glass slide as a dosimetric system. For this purpose the effects of the weakening of the coloration induced in the glass by gamma rays (Co 60 ) and the relationship between the absorbed dose of radiation and the ratio between the variation in absorbation value and the thickness of the glass irradiated, were studied. A study was also made of the use of the dye indicators bromothymol-blue, methyl-orange, Congo-red, neutral-red and p-nitrophenol, in aqueous solution, for radiation dose measurements. The bleaching of each indicator solution, under gamma-radiation (Co 60 ) was studied in oxygen and nitrogen atmospheres.(Author) [pt

  7. Dosimetric and non-dosimetric evaluation of PrecisePLAN computerized radiation treatment planning system

    International Nuclear Information System (INIS)

    Srinidhi, G.C.; Ramya, B.; Aswathi, Raj; Boban, Minu; Solomon, J.G.R; Vidyasagar, M.S.

    2008-01-01

    Cancer is a significant health care problem; on an average about half of all cancer patients are treated with radiation therapy worldwide. This mode of treatment uses complex technology that involves megavoltage radiation, computerized TPSs and delivery systems like MLCs, if not handled with the greatest of care, could lead to significant patient treatment errors and exposures of staff. As computer technology evolved and became more compact so did TPSs, while at the same time dose calculation algorithms and image display capabilities became more sophisticated. As part of the implementation of radiation therapy technology into clinical practice, it is important to recognize that such technology has inherent risks if not handled and administered properly

  8. Amorphous chalcogenide semiconductors for solid state dosimetric systems of high-energetic ionizing radiation

    International Nuclear Information System (INIS)

    Shpotyuk, O.

    1997-01-01

    The application possibilities of amorphous chalcogenide semiconductors use as radiation-sensitive elements of high-energetic (E > 1 MeV) dosimetric systems are analysed. It is shown that investigated materials are characterized by more wide region of registered absorbed doses and low temperature threshold of radiation information bleaching in comparison with well-known analogies based on coloring oxide glasses. (author)

  9. A Monte Carlo dosimetric quality assurance system for dynamic intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Takegawa, Hideki; Yamamoto, Tokihiro; Miyabe, Yuki; Teshima, Teruki; Kunugi, Tomoaki; Yano, Shinsuke; Mizowaki, Takashi; Nagata, Yasushi; Hiraoka, Masahiro

    2005-01-01

    We are developing a Monte Carlo (MC) dose calculation system, which can resolve dosimetric issues derived from multileaf collimator (MLC) design for routine dosimetric quality assurance (QA) of intensity-modulated radiotherapy (IMRT). The treatment head of the medical linear accelerator equipped with MLC was modeled using the EGS4 MC code. A graphical user interface (GUI) application was developed to implement MC dose computation in the CT-based patient model and compare the MC calculated results with those of a commercial radiotherapy treatment planning (RTP) system, Varian Eclipse. To reduce computation time, the EGS4 MC code has been parallelized on massive parallel processing (MPP) system using the message passing interface (MPI). The MC treatment head model and MLC model were validated by the measurement data sets of percentage depth dose (PDD) and off-center ratio (OCR) in the water phantom and the film measurements for the static and dynamic test patterns, respectively. In the treatment head model, the MC calculated results agreed with those of measurements for both of PDD and OCR. The MC could reproduce all of the MLC dosimetric effects. A quantitative comparison between the results of MC and Eclipse was successfully performed with the GUI application. Parallel speed-up became almost linear. An MC dosimetric QA system for dynamic IMRT has been developed, however there were large dose discrepancies between the MC and the measurement in the MLC model simulation, which are now being investigated. (author)

  10. SU-E-T-425: Feasibility of Establishing a National Postal Dosimetry System Using EBT3 Gafchromic Film

    International Nuclear Information System (INIS)

    Abdel-Rahman, W; Mohammed, I; Bamajboor, S

    2015-01-01

    Purpose: To evaluate the performance of a postal dosimeter consisting of EBT3 films and a miniature Lucite phantom to be used for photon beams output audits for mega-voltage photon beams across the Saudi Arabia. Methods: Two batches of EBT3 films were calibrated in 5 mega-voltage photon beams with energies ranging between 6 MV and 18 MV in the dose range between 0 to 4 Gy. A 4×4×20 cm 3 lucite phantom was constructed to be used as an irradiation phantom. The lucite irradiation phantom consists of two parts and allows for embedding a 2.5×2.0 cm 2 EBT3 film at 8.9 cm depth. Factors that convert the dose measured in the lucite irradiation phantom at 8.9 cm depth to the dose at 10 cm depth in water for 10×10 cm 2 field for different photon energies were calculated using the dosxyznrc/EGSnrcMP user code. The performance of the proposed postal dosimeter was tested in 17 different photon beams across 4 radiotherapy centres in Saudi Arabia. The outputs of the 17 beams are monitored by either the International Atomic Energy Agency or by the Radiological Physics Centre. Results: For the 17 photon beams, the average of the ratios of measured to stated outputs was 1.01 ± 0.02 and with a maximum ratio of 1.05. Conclusion: The results of our work indicate that the proposed postal dosimetry system can be used for national auditing of outputs for mega-voltage photon beams. The service can be offered to other national radiotherapy centres or to a be used for credentialing of centres participating in national trials

  11. SU-E-T-425: Feasibility of Establishing a National Postal Dosimetry System Using EBT3 Gafchromic Film

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rahman, W [KING FAHAD SPECIALIST HOSPITAL, Dammam, Eastern Province (Saudi Arabia); Mohammed, I [King Fahd University of Petroleum & Minerals, Dhahran, Eastern Province (Saudi Arabia); Bamajboor, S [Prince Sultan Military Medical City, Riyadh, Riyadh (Saudi Arabia)

    2015-06-15

    Purpose: To evaluate the performance of a postal dosimeter consisting of EBT3 films and a miniature Lucite phantom to be used for photon beams output audits for mega-voltage photon beams across the Saudi Arabia. Methods: Two batches of EBT3 films were calibrated in 5 mega-voltage photon beams with energies ranging between 6 MV and 18 MV in the dose range between 0 to 4 Gy. A 4×4×20 cm{sup 3} lucite phantom was constructed to be used as an irradiation phantom. The lucite irradiation phantom consists of two parts and allows for embedding a 2.5×2.0 cm{sup 2} EBT3 film at 8.9 cm depth. Factors that convert the dose measured in the lucite irradiation phantom at 8.9 cm depth to the dose at 10 cm depth in water for 10×10 cm{sup 2} field for different photon energies were calculated using the dosxyznrc/EGSnrcMP user code. The performance of the proposed postal dosimeter was tested in 17 different photon beams across 4 radiotherapy centres in Saudi Arabia. The outputs of the 17 beams are monitored by either the International Atomic Energy Agency or by the Radiological Physics Centre. Results: For the 17 photon beams, the average of the ratios of measured to stated outputs was 1.01 ± 0.02 and with a maximum ratio of 1.05. Conclusion: The results of our work indicate that the proposed postal dosimetry system can be used for national auditing of outputs for mega-voltage photon beams. The service can be offered to other national radiotherapy centres or to a be used for credentialing of centres participating in national trials.

  12. Application of a radiophotoluminescent glass dosimeter to nonreference condition dosimetry in the postal dose audit system

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, Hideyuki, E-mail: h-mizuno@nirs.go.jp; Fukumura, Akifumi; Fukahori, Mai [National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba-shi 263-8555 (Japan); Sakata, Suoh; Yamashita, Wataru; Takase, Nobuhiro [Association for Nuclear Technology in Medicine, 7-16, Nihonbashikodenmacho, Chuou-ku, Tokyo 103-0001 (Japan); Yajima, Kaori [Toho University Omori Medical Center, 6-11-1 Omori-Nishi, Ota-ku, Tokyo 143-8541 (Japan); Katayose, Tetsurou [Chiba Cancer Center, 666-2 Nitona-Cho, Chuoh-ku, Chiba-shi, Chiba 260-8717 (Japan); Abe-Sakama, Kyoko; Kanai, Tatsuaki [Gunma University, Heavy Ion Medical Research Center, 4-2, Aramaki-machi, Maebashi City, Gunma 371-8510 (Japan); Kusano, Yohsuke [Kanagawa Cancer Center, 1-1-2 Nakao, Asahi-ku, Yokohama-shi, Kanagawa 241-8515 (Japan); Shimbo, Munefumi [Saitama Medical Center, 1981, Kamoda, Kawagoe-shi, Saitama 350-8550 (Japan)

    2014-11-01

    Purpose: The purpose of this study was to obtain a set of correction factors of the radiophotoluminescent glass dosimeter (RGD) output for field size changes and wedge insertions. Methods: Several linear accelerators were used for irradiation of the RGDs. The field sizes were changed from 5 × 5 cm to 25 × 25 cm for 4, 6, 10, and 15 MV x-ray beams. The wedge angles were 15°, 30°, 45°, and 60°. In addition to physical wedge irradiation, nonphysical (dynamic/virtual) wedge irradiations were performed. Results: The obtained data were fitted with a single line for each energy, and correction factors were determined. Compared with ionization chamber outputs, the RGD outputs gradually increased with increasing field size, because of the higher RGD response to scattered low-energy photons. The output increase was about 1% per 10 cm increase in field size, with a slight difference dependent on the beam energy. For both physical and nonphysical wedged beam irradiation, there were no systematic trends in the RGD outputs, such as monotonic increase or decrease depending on the wedge angle change if the authors consider the uncertainty, which is approximately 0.6% for each set of measured points. Therefore, no correction factor was needed for all inserted wedges. Based on this work, postal dose audits using RGDs for the nonreference condition were initiated in 2010. The postal dose audit results between 2010 and 2012 were analyzed. The mean difference between the measured and stated doses was within 0.5% for all fields with field sizes between 5 × 5 cm and 25 × 25 cm and with wedge angles from 15° to 60°. The standard deviations (SDs) of the difference distribution were within the estimated uncertainty (1SD) except for the 25 × 25 cm field size data, which were not reliable because of poor statistics (n = 16). Conclusions: A set of RGD output correction factors was determined for field size changes and wedge insertions. The results obtained from recent postal dose

  13. Application of a radiophotoluminescent glass dosimeter to nonreference condition dosimetry in the postal dose audit system

    International Nuclear Information System (INIS)

    Mizuno, Hideyuki; Fukumura, Akifumi; Fukahori, Mai; Sakata, Suoh; Yamashita, Wataru; Takase, Nobuhiro; Yajima, Kaori; Katayose, Tetsurou; Abe-Sakama, Kyoko; Kanai, Tatsuaki; Kusano, Yohsuke; Shimbo, Munefumi

    2014-01-01

    Purpose: The purpose of this study was to obtain a set of correction factors of the radiophotoluminescent glass dosimeter (RGD) output for field size changes and wedge insertions. Methods: Several linear accelerators were used for irradiation of the RGDs. The field sizes were changed from 5 × 5 cm to 25 × 25 cm for 4, 6, 10, and 15 MV x-ray beams. The wedge angles were 15°, 30°, 45°, and 60°. In addition to physical wedge irradiation, nonphysical (dynamic/virtual) wedge irradiations were performed. Results: The obtained data were fitted with a single line for each energy, and correction factors were determined. Compared with ionization chamber outputs, the RGD outputs gradually increased with increasing field size, because of the higher RGD response to scattered low-energy photons. The output increase was about 1% per 10 cm increase in field size, with a slight difference dependent on the beam energy. For both physical and nonphysical wedged beam irradiation, there were no systematic trends in the RGD outputs, such as monotonic increase or decrease depending on the wedge angle change if the authors consider the uncertainty, which is approximately 0.6% for each set of measured points. Therefore, no correction factor was needed for all inserted wedges. Based on this work, postal dose audits using RGDs for the nonreference condition were initiated in 2010. The postal dose audit results between 2010 and 2012 were analyzed. The mean difference between the measured and stated doses was within 0.5% for all fields with field sizes between 5 × 5 cm and 25 × 25 cm and with wedge angles from 15° to 60°. The standard deviations (SDs) of the difference distribution were within the estimated uncertainty (1SD) except for the 25 × 25 cm field size data, which were not reliable because of poor statistics (n = 16). Conclusions: A set of RGD output correction factors was determined for field size changes and wedge insertions. The results obtained from recent postal dose

  14. Abreu system - A dosimetric system to evaluate basic parameters of photofluorographic X-ray machine

    International Nuclear Information System (INIS)

    Feital, J.C.

    1987-01-01

    In Brazil, photofluorographic X-ray machines are used for cuberculosis mass screening throughout the country. The exact number of these X-ray equipment is unknown but it is estimated to be around 1000 operating units. Twelve million miniature chest radiographs are taken per year. In order to make local inspections speedier and also aiming at its postal use, a system has been developed wich evaluates the entrace exposure of the patient, the X-ray beam half-value layer ( leading to the evaluation of the tube's total filtration ) and the beam's field size. It consists of a piece of cardboard where filters, TLDs and X-ray films are inserted. So far the system has been tested in 53 X-ray machines in Rio de Janeiro. The results show that it can be used in a national survey program. (Author) [pt

  15. Dosimetric commissioning and system for stereotactic radiation treatments based on linear accelerators with dynamic micromultilaminas collimators

    International Nuclear Information System (INIS)

    Ascension, Yudy; Alfonso, Rodolfo; Silvestre, Ileana

    2009-01-01

    Once installed and accepted, a system for stereotactic radiosurgery / stereotactic radiotherapy (CERs / RTE) requires, before starting to be used clinically in patients undergoing a process of commissioning dosimetry, which evaluates all geometric parameters, physical, Dosimetric and technical impact on the precision and accuracy of treatment to administer, and therefore its effectiveness. This process includes training and familiarization of the multidisciplinary team (medical physicists, radiation oncologists, neurosurgeons, dosimetrists, biomedical engineers) with the equipment and techniques used, the quality assurance program and special radiation protection standards for this technology. The aim of this work is to prepare the pre-clinical dosimetric conditions to ensure the quality and radiation safety of treatment with CER RTE. Treatment with CER RTE INOR has a linear accelerator equipped with a micro-multileaf collimator dynamic tertiary (dMLC 3Dline). The system aceleradordMLC geometric and dosimetric was calibrated, using ionization chambers miniature, diode and film dosimetry. The immobilization of the patient and location of the lesion is made by both invasive stereotactic frames and relocatable. The computerized planning of the CER / TEN is done with the ERGO system, for which commissioning is designed test cases of increasing complexity, using planes and anthropomorphic dummies, which help assess the accuracy of the dosimetric calculations and accuracy of the system as a whole. We compared the results of the planning system with measurements, showing that the discrepancies are within tolerances, so it is concluded that from the standpoint of physical dosimetry, the system-under-ERGO accelerator MLC is eligible for clinical use. (author)

  16. Development of a postal system for dosimetry quality control performed in photon beams produced by linear accelerators of clinical use

    International Nuclear Information System (INIS)

    Di Prinzio, R.

    1984-01-01

    In this work a different system is proposed which is able to verify the absorbed depth dose given at two different depths, the irradiation field homogeneity and its coincidence with the light field of the machine, the source to surface distance used and the beam nominal energy. These radiation field parameters are very important in the tumour treatment and they may help in the determination of the error sources of the absorbed depth dose. The system developed uses a water phantom, LiF thermoluminescent dosemeters and a radiographic film to evaluate such parameters. The postal system developed in this work has been tested in linear accelerators of 4 to 18 MV with good results. (author)

  17. Dosimetric systems developed in Brazil for the radiation processes quality control

    International Nuclear Information System (INIS)

    Galante, Ana Maria Sisti; Campos, Leticia Lucente

    2011-01-01

    In order to apply new technologies to the industrial processing of materials aiming economy, efficiency, speed and high quality, ionizing radiation has been used in medicine, archaeology, chemistry, food preservation and other areas. For this reason, the dosimetry area looks for improve current dosimeters and develop new materials for application on quality control of these processes. In Brazil, the research in the dosimetry area occurs with great speed providing many different dosimetric systems. The chemical dosimetry is the most used technique in routine dosimetry, which requires fast and accurate responses. This technique involves determination of absorbed dose by measuring chemical changes radiation induced in the materials. Different dosimetric systems were developed at IPEN for application on radiation process quality and all of them present excellent results; the low cost of these materials allows a more effective dose control, therefore, a larger area or volume can be monitored. (author).

  18. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: gas@cdtn.br, e-mail: pls@cdtn.br, e-mail: fcp@cdtn.br, e-mail: lcmb@cdtn.br, e-mail: pabloag@cdtn.br

    2009-07-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  19. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    International Nuclear Information System (INIS)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade

    2009-01-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  20. Amorphous chalcogenide semiconductors for solid state dosimetric systems of high-energetic ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shpotyuk, O. [Pedagogical University, Czestochowa (Poland)]|[Institute of Materials, Lvov (Ukraine)

    1997-12-31

    The application possibilities of amorphous chalcogenide semiconductors use as radiation-sensitive elements of high-energetic (E > 1 MeV) dosimetric systems are analysed. It is shown that investigated materials are characterized by more wide region of registered absorbed doses and low temperature threshold of radiation information bleaching in comparison with well-known analogies based on coloring oxide glasses. (author). 16 refs, 1 tab.

  1. RPL-SC dosimetric system for measuring gamma and neutron irradiation in case of emergency

    International Nuclear Information System (INIS)

    Khristova, M. G.

    1993-01-01

    A RPL-SC dosimetric system is designed based on radiophotoluminescence (RPL) and on the effect of fast neutron bombardment of silicon semiconductor (SC) diodes. The experimental prototype consists of a computerized automatic measurement system and an individual dosimetric cassette accommodating RPL and SC detectors. The equipment includes: a device for measurement of the direct voltage of Si diodes and the RPL light emitted by RPL detectors; a compartment with dosimetric cassettes to be measured; a manipulator with three positions executing automatic measurement of cassettes; a computer and a printer. The system operates in both manual and automatic modes. In the manual mode each step of the manipulator is set up by the operator who changes the ranges after they have been filled to capacity and registers the results. In the automatic mode the whole process of maintaining the supply and control voltage, of manipulator's operation, measuring, data recording and data processing are controlled by a specially designed computer programme. Main technical parameters: 1) Measurement range of absorbed dose: gamma rays - 10 -3 to 10 2 Gy; thermal neutrons - 10 -3 to 10 2 Gy; fast neutrons - 10 to 30 Gy. 2) Energy range: gamma rays - 0.04 to 1.25 MeV; thermal neutrons - 0.024 eV; fast neutrons - 0.3 to 14 MeV. 3) Relative measurement error - ±15% 4) Recurrent measurement of one and the same dose. 5) Measurement time of 1 detector - 15 sec. (author)

  2. Feasibility study of radiophotoluminescent glass rod dosimeter postal dose intercomparison for high energy photon beam

    International Nuclear Information System (INIS)

    Rah, Jeong-Eun; Kim, Siyong; Cheong, Kwang-Ho; Lee, Jeong-Woo; Chung, Jin-Beom; Shin, Dong-Oh; Suh, Tae-Suk

    2009-01-01

    A radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. In this study we evaluated whether the GRD would be suitable for external dosimetric audit program in radiotherapy. For this purpose, we introduced a methodology of the absorbed dose determination with the GRD by establishing calibration coefficient and various correction factors (non-linearity dose response, fading, energy dependence and angular dependence). A feasibility test of the GRD postal dose intercomparison was also performed for eight high photon beams by considering four radiotherapy centers in Korea. In the accuracy evaluation of the GRD dosimetry established in this study, we obtained within 1.5% agreements with the ionization chamber dosimetry for the 60 Co beam. It was also observed that, in the feasibility study, all the relative deviations were smaller than 3%. Based on these results, we believe that the new GRD system has considerable potential to be used for a postal dose audit program

  3. Development and application of a dosimetric methodology of therapeutic X radiation beams using a tandem system

    International Nuclear Information System (INIS)

    Sartoris, Carla Eri

    2001-01-01

    In radiotherapy the use of orthovoltage X radiation beams is still recommended; to obtain satisfactory results, a periodic control is necessary to check the performance of the ionization chambers and the radiation beams characteristics. This control is performed by using standard dosimetric procedures, as for example the determination of half-value layers and the absorbed dose rates. A Tandem system was established in this work using a pair of ionization chambers (a thimble type and a superficial type) used for measures in a medical institution, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The results obtained show the application of this method in dosimetric procedures of orthovoltage beams (radiotherapy) as a complement for a quality control program. (author)

  4. Establishment of postal audit system in intensity-modulated radiotherapy by radiophotoluminescent glass dosimeters and a radiochromic film.

    Science.gov (United States)

    Okamoto, Hiroyuki; Minemura, Toshiyuki; Nakamura, Mitsuhiro; Mizuno, Hideyuki; Tohyama, Naoki; Nishio, Teiji; Wakita, Akihisa; Nakamura, Satoshi; Nishioka, Shie; Iijima, Kotaro; Fujiyama, Daisuke; Itami, Jun; Nishimura, Yasumasa

    2018-04-01

    We developed an efficient postal audit system to independently assess the delivered dose using radiophotoluminescent glass dosimeters (RPLDs) and the positional differences of fields using EBT3 film at the axial plane for intensity-modulated radiotherapy (IMRT). The audit phantom had a C-shaped target structure as a planning target volume (PTV) with four measurement points for the RPLDs and a cylindrical structure as the organ at risk (OAR) for one measurement point. The phantoms were sent to 24 institutions. Point dose measurements with a 0.6 cm 3 PTW farmer chamber were also performed to justify glass dosimetry in IMRT. The measured dose with the RPLDs was compared to the calculated dose in the institution's treatment planning system (TPS). The mean ± 1.96σ of the ratio of the measured dose with the RPLDs to the farmer chamber was 0.997 ± 0.024 with no significant difference (p = .175). The investigations demonstrated that glass dosimetry was reliable with a high measurement accuracy comparable to the chamber. The mean ± 1.96σ for the dose differences with a reference of the TPS dose for the PTV and the OAR was 0.1 ± 2.5% and -2.1 ± 17.8%, respectively. The mean ± 1.96σ for the right-left and the anterior-posterior direction was -0.9 ± 2.8 and 0.5 ± 1.4 mm, respectively. This study is the first report to justify glass dosimetry for implementation in IMRT audit in Japan. We demonstrate that our postal audit system has high accuracy with a high-level criterion of 3%/3 mm. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Dosimetric validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator.

    Science.gov (United States)

    Narayanasamy, Ganesh; Saenz, Daniel L; Defoor, Dewayne; Papanikolaou, Niko; Stathakis, Sotirios

    2017-11-01

    The purpose of this study is to perform dosimetric validation of Monaco treatment planning system version 5.1. The Elekta VersaHD linear accelerator with high dose rate flattening filter-free photon modes and electron energies was used in this study. The dosimetric output of the new Agility head combined with the FFF photon modes warranted this investigation into the dosimetric accuracy prior to clinical usage. A model of the VersaHD linac was created in Monaco TPS by Elekta using commissioned beam data including percent depth dose curves, beam profiles, and output factors. A variety of 3D conformal fields were created in Monaco TPS on a combined Plastic water/Styrofoam phantom and validated against measurements with a calibrated ion chamber. Some of the parameters varied including source to surface distance, field size, wedges, gantry angle, and depth for all photon and electron energies. In addition, a series of step and shoot IMRT, VMAT test plans, and patient plans on various anatomical sites were verified against measurements on a Delta 4 diode array. The agreement in point dose measurements was within 2% for all photon and electron energies in the homogeneous phantom and within 3% for photon energies in the heterogeneous phantom. The mean ± SD gamma passing rates of IMRT test fields yielded 93.8 ± 4.7% based on 2% dose difference and 2 mm distance-to-agreement criteria. Eight previously treated IMRT patient plans were replanned in Monaco TPS and five measurements on each yielded an average gamma passing rate of 95% with 6.7% confidence limit based on 3%, 3 mm gamma criteria. This investigation on dosimetric validation ensures accuracy of modeling VersaHD linac in Monaco TPS thereby improving patient safety. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. A system for measuring and processing personnel dosimetric data

    International Nuclear Information System (INIS)

    Neetzel, C.R.; Rochetti, Luis

    1981-01-01

    An operative system for the measurement and on-line processing of personnel dosimetry data is described. The aim is to organize and rationalize the work involved in a personnel dosimetry service. The method considers the application to other areas of radiation protection, as well as the connection and exchange of files among the different personnel monitoring groups. The system can be interfaced with different computers (M.E.L.) [es

  7. Development of film dosimetric measurement system for verification of RTP

    International Nuclear Information System (INIS)

    Chen Yong; Bao Shanglian; Ji Changguo; Zhang Xin; Wu Hao; Han Shukui; Xiao Guiping

    2007-01-01

    Objective: To develop a novel film dosimetry system based on general laser scanner in order to verify patient-specific Radiotherapy Treatment Plan(RTP) in three-Dimensional Adaptable Radiotherapy(3D ART) and Intensity Modulated Radiotherapy (IMRT). Methods: Some advanced methods, including film saturated development, wavelet filtering with multi-resolution thresholds and discrete Fourier reconstruction are employed in this system to reduce artifacts, noise and distortion induced by film digitizing with general scanner; a set of coefficients derived from Monte Carlo(MC) simulation are adopted to correct the film over-response to low energy scattering photons; a set of newly emerging criteria, including γ index and Normalized Agreement Test (NAT) method, are employed to quantitatively evaluate agreement of 2D dose distributions between the results measured by the films and calculated by Treatment Planning System(TPS), so as to obtain straightforward presentations, displays and results with high accuracy and reliability. Results: Radiotherapy doses measured by developed system agree within 2% with those measured by ionization chamber and VeriSoft Film Dosimetry System, and quantitative evaluation indexes are within 3%. Conclusions: The developed system can be used to accurately measure the radiotherapy dose and reliably make quantitative evaluation for RTP dose verification. (authors)

  8. Abreu system - dosimetric system to evaluate the performance of the basic parameters of photofluorographic equipments

    International Nuclear Information System (INIS)

    Silva Feita, J.C. da.

    1986-01-01

    In Brazil, photofluorographic X-ray machines are used for tuberculosis mass screening throughout the country. The exact number of these X-ray equipment is unknown, but it is estimated to be around 1000 operating units. Twelve million miniature chest radiographs are taken per year. In order to make local inspections speedier and also aiming at its postal use, a system has been developed which evaluates the entrance exposure of the patients, the X-ray beam half-value layer (leading to the evaluation of the tube's total filtration) and the beam's field size. It consists of a piece of cardboard where filters, TLDs and X-ray films are inserted. So far the system has been tested in 53 X-ray machines. The results show that it can be used in a national survey program. The data collected were used for the calculation of doses and this showed the influence of field size and tube voltage on the dose to the thyroid, uterus, ovaries, bone marrow and lungs. Furthermore, the results can be used to estimate population doses and risks factors due to photofluorographic examinations. (author)

  9. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  10. Dosimetric methodology and reference system for diagnostic level X radiation

    International Nuclear Information System (INIS)

    Potiens, Maria da Penha Albuquerque

    1999-01-01

    Several methodologies for the calibration of diagnostic radiology instruments were developed and established at the Calibration Laboratory of IPEN. These established radiation qualities are recommended by international standards. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. A reference system was proposed using two identical ionization chambers developed at IPEN. They differ only by the collecting electrode material, one of aluminium and the other of graphite. The different energetic dependence of the chamber's response provided a ratio related to the tube potential. The variation of only 0.28%, from 14.3 to 111 keV, on the energetic dependence of the graphite electrode chamber, provided the possibility of air kerma rate determination in the studied radiation beams. (author)

  11. Physical-dosimetric enabling a dual linear accelerator 3D planning systems for radiotherapy

    International Nuclear Information System (INIS)

    Alfonso, Rodolfo; Martinez, William; Arelis, Lores; Morales, Jorge

    2009-01-01

    The process of commissioning clinical linear accelerator requires a dual comprehensive study of the therapeutic beam parameters, both photons Electron. All information gained by measuring physical and dosimetric these beams must be analyzed, processed and refined for further modeling in computer-based treatment planning (RTPS). Of professionalism of this process will depend on the accuracy and precision of the calculations the prescribed doses. This paper aims to demonstrate availability clinical linear accelerator system-RTPS with late radiotherapy treatments shaped beam of photons and electrons. (author)

  12. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE

    International Nuclear Information System (INIS)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L.

    2001-01-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10 5 Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  13. Qualitative dosimetric system for radiation processing. Technology for pilot scale preparation

    International Nuclear Information System (INIS)

    Moraru, R.

    1998-01-01

    Good manufacturing practice for radiation processing requires a very strictly tracking of the processed products. A method of labelling and identification of the irradiated and nonirradiated products is required. The qualitative dosimetric system provides a fast method for monitoring the product flow. Such dosimeters are attached on each product box, usually as labels, and offer a YES/NO information about the passing of products through the radiation field. Usually, this information consists in a change of colour. The qualitative dosimetric system that we realised is based on the degradation of polyvinylchloride (PVC) under radiation field. An amount of hydrochloric acid is released in this reaction. A pH indicator, included in the system, changes its colour at different absorbed dose. The changes of colour happened in a certain pH interval called turning range. We used as pH indicator the RED CONGO colorant with turning range of pH = 3 to 5 (from blue to red). A schematic view of the qualitative dosimeter is given. The initial colour is red and it continuously changes to brown, at 1 kGy absorbed dose, and to blue-green, for 5-100 kGy. The main features of this qualitative dosimetric system are: - Quick and easy to read information about product passing through radiation field; - Absorbed dose range, 1-300 kGy; - Independence of absorbed dose rate in the interval 5-100 kGy/h; - Stability, 3 year in the dark and 1 year in sun light; - Good reproducibility. The preparation technology consists in the following steps: 1. Preparation of the solutions: a) PVC in cyclohexanone solution b) RED CONGO in water solution; 2. Preparation of the system support consisting in dropping the PVC solution on adhesive labels; 3. Sample preparation consists in dropping the colorant solution on the system support; 4. Batch trial tests. The trial test was performed at IETI 10000 irradiation plant belonging to IFIN-HH and the reference absorbed dose was determined by Fricke dosimetry. The

  14. Web system for dosimetric data management of internal monitoring programme at IPEN

    International Nuclear Information System (INIS)

    Lima, Vanesa R. de; Rodriguez Junior, Orlando; Todo, Alberto S.

    2008-01-01

    Full text: The internal monitoring programme are carried out for the occupationally exposed workers that develop activities in the radioisotope production plant, fuel cycle facilities, waste management installations, cyclotron and the reactor facility at Institute of Nuclear Energy and Research (IPEN). According to the National Nuclear Energy Commission (CNEN), Regulation NN-3.01, the dose of each worker should be maintained at least for a period of 30 years. With this purpose, an online system, called 'IntDosWeb', was developed with the objective of the management for data dosimetric of internal monitoring programme. The system IntDosWeb, based on free software, was developed in programming language PHP and environment database PostgreSQL. This system is to be available at the local net, Intranet. The database maintains information about identification of the worker that handles non-sealed radioactive sources, physical and chemical characteristics of the radionuclides, monitoring types, measurement data and the dose. This system is able to generate annual reports of the individuals and the historical dose. Several simulation cases have been put into effect to check the on-line software functional capabilities. The users can access the dosimetric information according to following database field: monitoring period, monitoring type, intake pattern, radionuclide type and monitoring data from a specific installation or from each worker. The system was tested in the routinely service of internal dosimetry at IPEN. The rastreability of the information made in the internal monitoring programme was a success and also guaranteeing the reliability and integrity of the stored information. The IntDosWeb was shown as a helpful tool for analysis of the committed effective dose in the radiation protection programme, besides obeying the legal demands of the Brazilian Regulatory Commission. (author)

  15. Development of a dosimetric system for emergency situation involving person of the public

    International Nuclear Information System (INIS)

    Costa, Zelia Maria da

    1999-01-01

    A dosimetric system was developed for emergency situation based on electron spin resonance spectrometry (E.S.R.) and some materials such as tooth enamel, bovine bone, CaCO 3 and sugar as detector. The purpose of this work was to find common materials, which are both reliable and sensitive and make possible quickly to assess the absorbed dose. The research includes the collection and preparation of samples, the evaluation, treatment and interpretation of ESR signal and the procedure for dose reconstruction. The calibration of the dosemeter was performed using gamma radiation from a Co-60 source. The results obtained confirm the variability of the use of this system in case of an accident. (author)

  16. Detection of rain events in radiological early warning networks with spectro-dosimetric systems

    Science.gov (United States)

    Dąbrowski, R.; Dombrowski, H.; Kessler, P.; Röttger, A.; Neumaier, S.

    2017-10-01

    Short-term pronounced increases of the ambient dose equivalent rate, due to rainfall are a well-known phenomenon. Increases in the same order of magnitude or even below may also be caused by a nuclear or radiological event, i.e. by artificial radiation. Hence, it is important to be able to identify natural rain events in dosimetric early warning networks and to distinguish them from radiological events. Novel spectrometric systems based on scintillators may be used to differentiate between the two scenarios, because the measured gamma spectra provide significant nuclide-specific information. This paper describes three simple, automatic methods to check whether an dot H*(10) increase is caused by a rain event or by artificial radiation. These methods were applied to measurements of three spectrometric systems based on CeBr3, LaBr3 and SrI2 scintillation crystals, investigated and tested for their practicability at a free-field reference site of PTB.

  17. SU-F-P-11: Long Term Dosimetric Stability of 6 TomoTherapy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Smilowitz, J; Dunkerley, D; Geurts, M; Hill, P; Yadav, P [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: The dosimetric stability of six TomoTherapy units was analyzed to investigate changes in performance over time and with system upgrades. Methods: Energy and output were tracked using monitor chamber signal, onboard MVCT detector signal and external ion chamber measurements. The systems (and monitoring periods) include 3 Hi-Art (67, 61 and 65 mos.), 2 HDA (29 and 25 mos.) and one research unit (7 mo.). Dose Control Stability system (DCS) was installed on 4 systems. Output stability is reported as deviation from reference monitor chamber signal for all systems, and from an external chamber for 4 systems. Energy stability was monitored using the relative (center versus off-axis) MVCT detector signal and/or the ratio of chamber measurements at 2 depths. The results from the clinical systems were used to benchmark the stability of the research unit, which has the same linear accelerator but runs at a higher dose rate. Results: The output based on monitor chamber data of all six systems is very stable. Non- DCS had a standard deviation of 1.7% and 1.8%. As expected, DCS systems had improved standard deviation: 0.003–0.05%. The energy was also very stable for all units. The standard deviation in exit detector flatness was 0.02–0.3%. Ion chamber output and 20/10 cm ratios supported these results. The stability for the research system, as monitored with a variety of metrics, is on par with the existing systems. Conclusion: The output and energy of six TomoTherapy units over a total of almost 10 years is quite stable. For each system, the results are consistent between the different measurement tools and techniques, proving not only the dosimetric stability, but that these quality parameters can be confirmed with various metrics. A research unit operating at a higher dose rate performed as well as the clinical treatment units. University of Wisconsin and Accuray Inc. (vendor of TomoTherapy systems) have a research agreement which supplies funds for research to

  18. The calculation of costs of postal network and universal postal service based on standard and average cost principles

    Directory of Open Access Journals (Sweden)

    Blagojević Mladenka Z.

    2017-01-01

    Full Text Available The provision of universal postal service involves high costs for operator, especially in rural areas. The aim of this paper is to propose and test tool for managing the cost of providing universal postal service and maintaining the postal network in order to facilitate understanding of the problem in the sector. The proposed approach use standard prices and standard quantities (the redefined number of postal units, the number of employees, etc. as well as average costs for calculation of the costs of the universal postal service and postal network. The methodology provides the efficiency analysis, benchmarking and identification of causes of poor performance of management and resource allocation. It can be used for postal operators that do not have modern accounting systems.

  19. Development of a thermally stimulated exoelectron emission (TSEE) system for dosimetric applications

    International Nuclear Information System (INIS)

    Rocha, Felicia del Gallo

    1997-01-01

    A thermally stimulated exoelectron emission measuring system (TSEE) with a counting (reader) and a heating system was designed, constructed and tested for the dosimetry of weakly penetrating radiations, such as alpha and beta particles and low energy X rays. The counting system consists of a 271 windowless gas-flow proportional counter, while the heating system is composed by a temperature programmer that provides linear heating of the samples. The characterization of the proportional counter was done, as well as the tests to verify the performance of the counting system with reference TSEE materials, such as beryllium oxide (BeO) and magnesium oxide (MgO) single crystals. The dosimetric characteristics of some materials as pure calcium sulphate (CaS0 4 ) sintered pellets and with 10% of graphite in its composition, lithium fluoride doped with magnesium, copper and phosphor (LiF:Mg,Cu,P), lithium fluoride (LiF) thin films on aluminum and stainless steel substrates and BeO on graphite substrates were studied. As an application, the feasibility of the use of pure calcium sulphate sintered pellets and others with 10% of graphite in area monitoring of an electron accelerator with variable energy was studied. The obtained results show the usefulness of this system in the dosimetry of weakly penetrating radiations. (author)

  20. BeOSL system for personal dosimetry : dosimetric characteristics and practical application

    International Nuclear Information System (INIS)

    Mende, E.

    2015-10-01

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  1. LabVIEW-based control and acquisition system for the dosimetric characterization of a silicon strip detector.

    Science.gov (United States)

    Ovejero, M C; Pérez Vega-Leal, A; Gallardo, M I; Espino, J M; Selva, A; Cortés-Giraldo, M A; Arráns, R

    2017-02-01

    The aim of this work is to present a new data acquisition, control, and analysis software system written in LabVIEW. This system has been designed to obtain the dosimetry of a silicon strip detector in polyethylene. It allows the full automation of the experiments and data analysis required for the dosimetric characterization of silicon detectors. It becomes a useful tool that can be applied in the daily routine check of a beam accelerator.

  2. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Rankine, Leith J., E-mail: Leith_Rankine@med.unc.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Department of Radiation Oncology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Mein, Stewart [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Cai, Bin; Curcuru, Austen [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Juang, Titania; Miles, Devin [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Mutic, Sasa; Wang, Yuhe [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Oldham, Mark [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Li, H. Harold, E-mail: hli@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States)

    2017-04-01

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We

  3. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    International Nuclear Information System (INIS)

    Rankine, Leith J.; Mein, Stewart; Cai, Bin; Curcuru, Austen; Juang, Titania; Miles, Devin; Mutic, Sasa; Wang, Yuhe; Oldham, Mark; Li, H. Harold

    2017-01-01

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We

  4. Evaluation of the dosimetric performance characteristic of fluoroscopy system used in medicine

    International Nuclear Information System (INIS)

    Qi Xuesong; Wei Kedao; Cheng Yuxi; Zhou Qifu; Ge Lijuan; Hou Changsong

    2001-01-01

    Objective: To discuss establishment of diagnostic reference dose value in fluoroscopic examinations for survey of 16 different types of fluoroscopy systems. Methods: Choosing dosimetric characteristic parameters including: IIESDR, ESDR (typical value) and ESDR max (ESDR maximum), and DAP, which was calibrated in situ on the X-ray unit. Results: Results of dose survey are summarized in three tables, from these we could get wide changes in accordance with those in many other countries resulting from maximum and minimum of IIESDR, ESDR and ESDRmax when measurements were performed at same entrance field size on I.I. Image Intensifier of the 15 fluoroscopy systems and under conditions of ABC. And also we could get less changes of DAP mean values, though differences for patient weight, technological parameters of fluoroscopic exam setting, fluoroscopic time and number of film were more remarkable. Conclusions: Measurements on IIESDR, ESDR (typical value) and ESDRmax (ESDR maximum) are not satisfied as diagnostic reference level. But it is suggested that DAP values, in fluoroscopic exam, are used as a tool to achieve this. (author)

  5. Dosimetric validation of planning system Eclipse 10 in partial breast irradiation treatments with IMRT

    International Nuclear Information System (INIS)

    Velazquez T, J. J.; Gutierrez M, J. G.; Ortiz A, C. S.; Chagoya G, A.; Gutierrez C, J. G.

    2015-10-01

    Partial breast irradiation is a new type of external radiation therapy to treat breast cancer in early clinical stages. Consist of administering to the channel surgical high doses of radiation in few treatment sessions. In this paper the dose calculations of the planning system Eclipse version 10 for a treatment of partial breast irradiation with X-rays beams (6 MV) intensity modulated were compared against the measurements made with OSL dosimeters and radio-chromic dye film. An anthropomorphic mannequin was used in which OSL dosimeters were collocated near the surface, an inside the radio-chromic dye film one plate; with this latest one dimensional dose distribution was measured. Previously dosimeters were calibrated irradiating them with a beam of X-rays 6 MV under the conditions specified in the IAEA-398 protocol. The OSL dosimeters were read in the Micro star Landauer equipment, the radio-chromic dye films were read with a scanner Epson 10000-Xl and analyzed with FilmCal and PTW Verisoft programs. The differences between measured and calculated dose were as follows: 3.6±1% for the OSL dosimeter and 96.3±1% of the analyzed points approved the gamma index criterion (3%, 3m m) when comparing the matrices of calculated dose and measured with the radio-chromic dye film. These results confirm the good dosimetric performance of planning system used under specific conditions used in the partial breast irradiation technique. (Author)

  6. Sensitization of glycine (spectrophotometric read-out) dosimetric system using sorbitol

    International Nuclear Information System (INIS)

    Shinde, S.H.; Mukherjee, T.

    2009-01-01

    Glycine spectrophotometric read-out systems have a useful dose range of 15-4000 Gy. An attempt was made to sensitize it using sorbitol as a sensitizer. Optimum compositions of aqueous acidic solutions of ferrous ammonium sulphate-xylenol orange (XO), i.e. FX and sorbitol-ferrous ammonium sulphate-xylenol orange, i.e. SFX, for 400 mg of glycine, which gives maximum dosimetric response for any given dose, were established. Molar absorption coefficient values of ferric-XO-glycine complex, i.e. ε-values, were determined for glycine system in FX and SFX. These values were found to be 8410 and 15,000 m 2 mol -1 respectively, indicating that an enhancement or sensitivity factor of about 1.78 can be achieved by sorbitol for glycine in SFX. This factor was further confirmed by measuring the gamma dose response of glycine in FX and in SFX for four different doses, viz. 37.8, 75.5, 151 and 302 Gy. It was observed that dose response of glycine in SFX is about 77% more than that of glycine in FX. The maximum variation observed in response of glycine in FX or SFX was found to be within ±1.5%.

  7. Comparison and utilization of two dosimetric systems for e-beam industrial irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fortes, Marcio Z., E-mail: mzamboti@aceletron.com.b [Aceletron Irradiacao Industrial, Rio de Janeiro, RJ (Brazil). Gerencia Tecnica e Operacoes; Sousa, Fernando N.C. de; Boente, Otavio C., E-mail: fernando.nuno@aceletron.com.b, E-mail: otavio@aceletron.com.b [Aceletron Irradiacao Industrial, Rio de Janeiro, RJ (Brazil). Gerencia de Desenvolvimento de Produtos; Sousa, Nuno R.A., E-mail: engenheiro.nuno.sousa@gmail.co [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia Mecanica

    2009-07-01

    The utilization of electron linear accelerators (LINAC's) for industrial irradiation of several products like turf, sterilization of medical products, cosmetics, polymers, food, and gems, can only be successful if a reliable dosimetric system is chosen. There are several different available technologies and two were selected for this study. The first one uses alanine dosimeters which can be read with electron spin resonance spectrometers (ESR); the second uses B3 radiochromic dosimeters which are read with a spectrophotometer. This study presents a comparison of both technologies in the dose range of 1 to 80 kGy, taking into account initial cost, precision, reading time, calibration, among others, for a typical 24 hour production run, and for normal operational routines and tests. It is shown that each system has its own advantages and disadvantages, and that both can be used in an e-beam installation. However, for industrial applications it is necessary to optimize the process, so it is presented which dosimeter is used for each routine application. (author)

  8. Study and evaluation of the Siemens virtual wedge factor: dosimetric monitor system and variable field effects

    Energy Technology Data Exchange (ETDEWEB)

    Sendon Rio, J R Sendon; Martinez, C Otero; GarcIa, M Sanchez; Busto, R Lobato; Vega, V Luna; Sueiro, J Mosquera; Camean, M Pombar [Servizo de Radiofisica e Proteccion Radioloxica, Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Santiago de Compostela (Spain)], E-mail: jose.ramon.sendon.del.rio@sergas.es

    2008-03-07

    In the year 1997 Siemens introduced the virtual wedge in its accelerators. The idea was that a dose profile similar to that of a physical wedge can be obtained by moving one of the accelerator jaws at a constant speed while the dose rate is changing. This work explores the observed behaviour of virtual wedge factors. A model is suggested which takes into account that at any point in time, when the jaw moves, the dose at a point of interest in the phantom is not only due to the direct beam. It also depends on the scattered radiation in the phantom, the head scatter and the behaviour of the monitoring system of the accelerator. Measurements are performed in a Siemens Primus accelerator and compared to the model predictions. It is shown that the model agrees reasonably well with measurements spanning a wide range of conditions. A strong dependence of virtual wedge factors on the dosimetric board has been confirmed and an explanation has been given on how the balance between different contributions is responsible for virtual wedge factors values.

  9. Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source.

    Science.gov (United States)

    Richardson, Susan; Garcia-Ramirez, Jose; Lu, Wei; Myerson, Robert J; Parikh, Parag

    2012-11-01

    To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent(®) Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy∕min while the RT-50 is 10-12 Gy∕min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately ±5.2%. The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.

  10. Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source

    International Nuclear Information System (INIS)

    Richardson, Susan; Garcia-Ramirez, Jose; Lu Wei; Myerson, Robert J.; Parikh, Parag

    2012-01-01

    Purpose: To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent ® Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Methods: Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. Results: The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy/min while the RT-50 is 10–12 Gy/min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately ±5.2%. Conclusions: The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.

  11. Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Susan; Garcia-Ramirez, Jose; Lu Wei; Myerson, Robert J.; Parikh, Parag [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States); Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States)

    2012-11-15

    Purpose: To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent{sup Registered-Sign} Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Methods: Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. Results: The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy/min while the RT-50 is 10-12 Gy/min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately {+-}5.2%. Conclusions: The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.

  12. Comparison of Panasonic’s Dosimetric System with Gamma-31 Dosimeters

    Directory of Open Access Journals (Sweden)

    Paweł Urban

    2013-01-01

    Full Text Available Equipment being used in medical or industrial institutions is often a source of ionizing radiation with different energies and types, which complicates the detection and assessment of doses. Up until now, for dosimetric measurements of ionizing radiation, Gamma-31 dosimeters have been used in the Central Mining Institute for many years. Now, this system will be expanded by a Panasonic system, for which measurement procedures were developed and comparisons with other dosimeters were held. The method is based on a four-element dosimeters UD-802 Panasonic equipped with CaSO and LiBO detectors additionally sheltered by filters of different surface mass. The use of UD-802 dosimeters, in contrast to Gamma-31 dosimeters, permits measuring radiation doses in a different range of photon energy. Consequently, it is possible to obtain a more accurate analysis of the hazards caused by gamma radiation in underground mines. The publication includes a description of the dosimetry system and presents the results of measurements conducted by means of both types of dosimeters. In order to verify the correctness of the indications of the new dosimetry system a series of measurements were carried out, which allowed examining the behaviour of the dosimeters under different environmental conditions. As a place of exposure, the selected laboratories in the Silesian Centre for Environmental Radiometry were chosen, where the work is connected with (TENORM and equipment producing ionizing radiation or containing sources of this type of radiation. Moreover, to observe the dosimeters behaviour in difficult environmental conditions, they were exposed in water treatment plants and an underground potassium salt mine.

  13. Comparison of dosimetric properties of three commercial multi leaf collimator systems

    International Nuclear Information System (INIS)

    Hoever, K.H.; Hesse, B.M.; Haering, P.; Rhein, B.; Bannach, B.; Doll, T.; Doerner, K.J.

    1996-01-01

    Purpose: The dosimetric properties of different designs of multi leaf collimators used for the generation of irregular fields will be measured and compared with each other. Using multi leaf collimators is a practical method of achieving conformal therapy. The use for complex conformal treatment fields to be given in either in static or dynamic mode depends much on the leaf end penumbra and the leaf side penumbra as well as the transmission through the leafs. Penumbra and leakage caused by the leaves therefore are of special interest in this intercomparison. Material and Methods: To investigate the dosimetric properties of three multi leaf collimators of different technical design, measurements have been taken at two different facilities. Until now, comparative measurements have been performed for the following devices. The new Siemens double focusing MLC with 29 opposite leaf pairs, installed at the Mevatron Experimental in the German Cancer Research Center, Heidelberg. The energy used was 15 MV and 6 MV. The Philips quasi-double focusing MLC with 40 opposite leaf pairs, installed at the SL25 in the University Duesseldorf. The leaves move in a plane rather than on a circular arc and have rounded ends to reduce penumbra. The energy used was 25 MV and 6 MV. The Leibinger non-focusing micro-MLC with 40 opposite leaf pairs. This MLC was specially designed for stereotactic irradiation of the brain. The comparative study is to be continued and extended to involve additional devices in the future. Both, the film densitometry and a newly designed ten-bit Beam Imaging System BIS-710 developed by Wellhoefer company were used. The BIS-710 was developed especially for quantitative dose measuring, whereas most of the existing Portal Imaging Systems are used for image display only. The BIS-710 contains a camera for 10-bit digital data output. The size of each of the 512 x 512 detector elements is 0.6 mm x 0.6 mm Results: Measurements taken with the BIS-710 and with film

  14. Model-Based Control for Postal Automation and Baggage Handling

    NARCIS (Netherlands)

    Tarau, A.N.

    2010-01-01

    In this thesis we focus on two specific transportation systems, namely postal automation and baggage handling. Postal automation: During the last decades the volume of magazines, catalogs, and other plastic wrapped mail items that have to be processed by post sorting centers has increased

  15. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  16. Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy

    International Nuclear Information System (INIS)

    Knutsen, Stig; Hafslund, Rune; Monge, Odd R.; Valen, Harald; Muren, Ludvig Paul; Rekstad, Bernt Louni; Krohn, Joergen; Dahl, Olav

    2001-01-01

    Purpose: Episcleral plaque therapy (EPT) is applied in the management of some malignant ocular tumors. A customized configuration of typically 4 to 20 radioactive seeds is fixed in a gold plaque, and the plaque is sutured to the scleral surface corresponding to the basis of the intraocular tumor, allowing for a localized radiation dose delivery to the tumor. Minimum target doses as high as 100 Gy are directed at malignant tumor sites close to critical normal tissues (e.g., optic disc and macula). Precise dosimetry is therefore fundamental for judging both the risk for normal tissue toxicity and tumor dose prescription. This paper describes the dosimetric verification of a commercially available dedicated treatment planning system (TPS) for EPT when realistic multiple-seed configurations are applied. Materials and Methods: The TPS Bebig Plaque Simulator is used to plan EPT at our institution. Relative dose distributions in a water phantom, including central axis depth dose and off-axis dose profiles for three different plaques, the University of Southern California (USC) No. 9 and the Collaborative Ocular Melanoma Study (COMS) 12-mm and 20-mm plaques, were measured with a diode detector. Each plaque was arranged with realistic multiple 125 I seed configurations. The measured dose distributions were compared to the corresponding dose profiles calculated with the TPS. All measurements were corrected for the angular sensitivity variation of the diode. Results: Single-seed dose distributions measured with our dosimetry setup agreed with previously published data within 3%. For the three multiple-seed plaque configurations, the measured and calculated dose distributions were in good agreement. For the central axis depth doses, the agreement was within 4%, whereas deviations up to 11% were observed in single points far off-axis. Conclusions: The Bebig Plaque Simulator is a reliable TPS for calculating relative dose distributions around realistic multiple 125 I seed

  17. 76 FR 47275 - Postal Service Initiative on Retail Postal Locations

    Science.gov (United States)

    2011-08-04

    .... Id. The RAO initiative applies to postal retail facilities across the country, without limit to geography or population, and is driven by Headquarters. The Commission finds that because the Postal Service... be applied in the RAO initiative. Id. at 19-23. \\3\\ See 39 CFR Part 241. The Request and all...

  18. Dosimetric characterization of the Exradin W1 plastic scintillator detector through comparison with an in-house developed scintillator system

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, Claus F.; Andersen, Claus E.

    2014-01-01

    method, but differing primarily in the signal detection hardware. The two systems were compared with respect to essential dosimetric properties, with the purpose of testing their performance under conditions less well discussed in the literature. A Farmer ionization chamber was used as the primary...... is therefore advised if using either system for measurements in large fields or under circumstances where the fibre irradiation geometry is unfavourable. Measurements of reference dose to water yielded differences up to 1.5% when compared with the Farmer ionization chamber for all investigated beam qualities...

  19. 78 FR 76333 - New Postal Product

    Science.gov (United States)

    2013-12-17

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2011-4; Order No. 1901] New Postal Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service... not materially affect the cost coverage'' of the product. Id. The Postal Service seeks to incorporate...

  20. Foetal dosimetry--is the ICRP dosimetric system for humans now complete?

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Steve [Westlakes Research Institute, Cumbria (United Kingdom)

    2002-03-01

    Internal dosimetry is possibly the most complex area of science associated with radiological protection, and has a long history. Primary control of internal exposure now relied on control of annual intakes rather than limitation of organ burdens. Although it took nearly a decade for regulations and hence the practice of occupational radiation protection to fully adopt the new recommendations, the new dosimetric concepts were quite rapidly adopted in the assessment of public exposure because the new methods provided a more natural means of assessing the significance of exposure to a combination of external and internal exposure involving a number of different radionuclides. As a result, following the ICRP's initial publication of dosimetric models for occupational exposure, adaptations became available to cover environmental exposure, including the exposure of infants and children. Increasingly sophisticated biokinetic and dosimetric models have now been developed which, together with the welcome availability of dose per unit intake factors in CD-ROM form make it easy for the radiation protection practitioner to assess committed effective doses, and committed equivalent doses to individual organs, to occupationally exposed adults and environmentally exposed infants, children and adults. The inability to readily assess doses to the developing foetus has, however, long been perceived as a significant gap in knowledge with implications for the study of childhood leukaemia in the vicinity of nuclear installations and possibly also the control of occupational exposure for women of child-bearing age. The first systematic assessment of doses to the foetus was in connection with the study of childhood leukaemia in the vicinity of Sellafield in the UK, for which preliminary models were developed. Since that time a few publications giving guidance on the calculation of foetal doses have emerged and more sophisticated assessments of foetal dose have been reported

  1. A new fully integrated X-ray irradiator system for dosimetric research

    International Nuclear Information System (INIS)

    Richter, D.; Mittelstraß, D.; Kreutzer, S.; Pintaske, R.; Dornich, K.; Fuchs, M.

    2016-01-01

    A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required. - Highlights: • Bench top X-ray irradiator provides variable dose-rates. • Simulation of low energy photon irradiation and hardening of X-ray. • Al-hardening for the irradiation of H_2O, BeO, Al_2O_3, quartz, feldspars and zircon. • Dosimetric dating equipment for luminescence and ESR.

  2. Human respiratory tract model for radiological protection: A revision of the ICRP Dosimetric Model for the Respiratory System

    International Nuclear Information System (INIS)

    Bair, W.J.

    1989-01-01

    In 1984, the International Commission on Radiological Protection (ICRP) appointed a task group of Committee 2 to review and revise, as necessary, the ICRP Dosimetric Model for the Respiratory System. The model was originally published in 1966, modified slightly in Publication No. 19, and again in Publication No. 30 (in 1979). The task group concluded that research during the past 20 y suggested certain deficiencies in the ICRP Dosimetric Model for the Respiratory System. Research has also provided sufficient information for a revision of the model. The task group's approach has been to review, in depth, morphology and physiology of the respiratory tract; deposition of inhaled particles in the respiratory tract; clearance of deposited materials; and the nature and specific sites of damage to the respiratory tract caused by inhaled radioactive substances. This review has led to a redefinition of the regions of the respiratory tract for dosimetric purposes. The redefinition has a morphologic and physiological basis and is consistent with observed deposition and clearance of particles and with resultant pathology. Regions, as revised, are the extrathoracic (E-T) region, comprising the nasal and oral regions, the pharynx, larynx, and upper part of the trachea; the fast-clearing thoracic region (T[f]), comprising the remainder of the trachea and bronchi; and the slow-clearing thoracic region (T[s]), comprising the bronchioles, alveoli, and thoracic lymph nodes. A task group report will include models for calculating radiation doses to these regions of the respiratory tract following inhalation of representative alpha-, beta-, and gamma-emitting particulate and gaseous radionuclides. The models may be implemented as a package of computer codes available to a wide range of users

  3. Experience in the performance of a system of dosimetric design of radiotherapy and prospects of its development

    International Nuclear Information System (INIS)

    Tsyb, A.F.; Mardynskij, Yu.S.; Chilingarov, K.M.

    1987-01-01

    A model of a system of dosimetric design of radiotherapy on the basis of SM-4 and ES-1033 computers has been developed and is being tested. Radiotherapy for over 600 patients with tumors of different sites was designed within 1 year. The simplicity of the system allowed a radiologist to take an active part in the choice of a favourable radiotherapy design. Four variants of dose distributions on an average were computed for each patient. A study of the time characteristics of the system has shown that the time of input of the data on a patient and beam parameters does not practically depend on the computer speed and lasts for an average of 15 min. Dose field computation and optimization of inputs vary from 0.4 to 6 min depending on a volume of computation and computer type. A one-task computer system with one working place and memory is able to meet the requirements in dosimetric design for 2-3 radiotherapeutic units. More units will require multitask and all-purpose computers with 2 and more working places. Minimum standards of computer memory and speed are the same as in the first case

  4. Dosimetric characterization of radionuclides for systemic tumor therapy: Influence of particle range, photon emission, and subcellular distribution

    International Nuclear Information System (INIS)

    Uusijaervi, Helena; Bernhardt, Peter; Ericsson, Thomas; Forssell-Aronsson, Eva

    2006-01-01

    Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability of toxicity in, e.g., the bone marrow. The aim of this study was to investigate the dosimetric properties according to particle range, photon emission, and subcellular radionuclide distribution, of a selection of radionuclides used or proposed for radionuclide therapy, and to investigate the possibility of dividing radionuclides into groups according to their dosimetric properties. The absorbed dose rate to the tumors divided by the absorbed dose rate to the normal tissue (TND) was estimated for different tumor sizes in a mathematical model of the human body. The body was simulated as a 70-kg ellipsoid and the tumors as spheres of different sizes (1 ng-100 g). The radionuclides were either assumed to be uniformly distributed throughout the entire tumor and normal tissue, or located in the nucleus or the cytoplasm of the tumor cells and on the cell membrane of the normal cells. Fifty-nine radionuclides were studied together with monoenergetic electrons, positrons, and alpha particles. The tumor and normal tissue were assumed to be of water density. The activity concentration ratio between the tumor and normal tissue was assumed to be 25. The radionuclides emitting low-energy electrons combined with a low photon contribution, and the alpha emitters showed high TND values for most tumor sizes. Electrons with higher energy gave reduced TND values for small tumors, while a higher photon contribution reduced the TND values for large tumors. Radionuclides with high photon contributions showed low TND value for all tumor sizes studied. The radionuclides studied could be divided into four main groups according to their TND values: beta emitters, Auger electron

  5. Dosimetric comparison of treatment planning systems in irradiation of breast with tangential fields

    International Nuclear Information System (INIS)

    Cheng, C.-W.; Das, Indra J.; Tang, Walter; Chang Sha; Tsai, J.-S.; Ceberg, Crister; Gaspie, Barbara de; Singh, Rajinder; Fein, Douglas A.; Fowble, Barbara

    1997-01-01

    Purpose: The objectives of this study are: (1) to investigate the dosimetric differences of the different treatment planning systems (TPS) in breast irradiation with tangential fields, and (2) to study the effect of beam characteristics on dose distributions in tangential breast irradiation with 6 MV linear accelerators from different manufacturers. Methods and Materials: Nine commercial and two university-based TPS are evaluated in this study. The computed tomographic scan of three representative patients, labeled as 'small', 'medium' and 'large' based on their respective chest wall separations in the central axis plane (CAX) were used. For each patient, the tangential fields were set up in each TPS. The CAX distribution was optimized separately with lung correction, for each TPS based on the same set of optimization conditions. The isodose distributions in two other off-axis planes, one 6 cm cephalic and the other 6 cm caudal to the CAX plane were also computed. To investigate the effect of beam characteristics on dose distributions, a three-dimensional TPS was used to calculate the isodose distributions for three different linear accelerators, the Varian Clinac 6/100, the Siemens MD2 and the Philips SL/7 for the three patients. In addition, dose distributions obtained with 6 MV X-rays from two different accelerators, the Varian Clinac 6/100 and the Varian 2100C, were compared. Results: For all TPS, the dose distributions in all three planes agreed qualitatively to within ± 5% for the 'small' and the 'medium' patients. For the 'large' patient, all TPS agreed to within ± 4% on the CAX plane. The isodose distributions in the caudal plane differed by ± 5% among all TPS. In the cephalic plane in which the patient separation is much larger than that in the CAX plane, six TPS correctly calculated the dose distribution showing a cold spot in the center of the breast contour. The other five TPS showed that the center of the breast received adequate dose. Isodose

  6. Characterization and standardization of a thermoluminescent dosimetric system to ultraviolet and laser radiation using CaSO4:Dy

    International Nuclear Information System (INIS)

    Grossi, Fabio Henrique

    2002-01-01

    The photo transferred thermoluminescence (PTTL) was used to characterize a dosimetric system to the laser and ultraviolet radiation. Dysprosium activated calcium sulphate samples (CaSO 4 :Dy) used are produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN) and have proved been an excellent dosimetric material for non ionizing radiation. PTTL signal was studied for UV radiation detection in the 220 to 450 nm range and for laser radiation in the 193 to 1.160 nm range. The samples presented more sensibility to the 193, 250, 310 and 337 nm wavelengths and no sensibility to infrared region. The samples presented linear PTTL in function of radiant exposure, excitation gamma dose in the range between 5 and 100 Gy and laser beam diameter between 2 and 6 nm. Another parameters studied were the angular dependence, UV lower exposure limit and PTTL signal optical fading. Spread laser radiation analysis was performed in the Ophthalmologic Department of Universidade Federal de Sao Paulo (UNIFESP) surgical center, showing that samples positioned as far as 4 m from laser source are sensitized to the laser radiation, as well as evaluating the laser exposure received by workers of medical area. A method to send the samples by mail was developed to the studies performed in the UNIFESP. (author)

  7. 75 FR 58449 - Postal Rates

    Science.gov (United States)

    2010-09-24

    ... feel free to discuss the merits of the current Bulk Metered Mail (BMM) base category as well as a... American Postal Workers Union, AFL-CIO in that docket express a more general desire to re- evaluate and...

  8. 75 FR 166 - Postal Product Price Changes

    Science.gov (United States)

    2010-01-04

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2009-49; Order No. 371] Postal Product Price Changes...-filed Postal Service request to change prices for a Global Plus 2 contract. This notice provides an...: On December 21, 2009, the Postal Service filed a notice that prices for the Global Plus 2 contract at...

  9. 78 FR 79024 - New Postal Product

    Science.gov (United States)

    2013-12-27

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2011-50; Order No. 1922] New Postal Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service... new product name. Id. at 1 n.1. Attachment A--a redacted copy of the amendment to the existing...

  10. 78 FR 43246 - New Postal Product

    Science.gov (United States)

    2013-07-19

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2013-15; Order No. 1779] New Postal Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service... competitive products by market dominant products. Id. II. Notice of Filing Interested persons may submit...

  11. 78 FR 76863 - New Postal Product

    Science.gov (United States)

    2013-12-19

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2014-12; Order No. 1905] New Postal Product AGENCY... Competitive Multi-Service Agreements with Foreign Postal Operators 1 (MC2010-34) product on the competitive product list. Notice at 3. \\1\\ Notice of United States Postal Service of Filing Functionally Equivalent...

  12. 75 FR 43581 - New Postal Product

    Science.gov (United States)

    2010-07-26

    ... Postal Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing... the competitive product list. The Postal Service has also filed related contracts. This notice... Paragraphs I. Introduction The Postal Service seeks to add a new product, Global Plus 1A, to the competitive...

  13. 75 FR 53353 - New Postal Product

    Science.gov (United States)

    2010-08-31

    ... will permit the Postal Service to create pricing for any combination of products in an equivalent... Agreements with Foreign Postal Operators be added as a new product to the competitive product list. Id. at 8... POSTAL REGULATORY COMMISSION [Docket Nos. MC2010-34 and CP2010-95; Order No. 517] New Postal...

  14. 75 FR 27375 - Postal Rate Case Management

    Science.gov (United States)

    2010-05-14

    ... POSTAL REGULATORY COMMISSION [Docket No. PI2010-3; Order No. 456] Postal Rate Case Management AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is seeking comments relevant to management of an anticipated exigent postal rate case. It has scheduled a technical conference...

  15. Abreu System - a dosimetric system to evaluate basic functioning parameters of roentgenography equipment

    International Nuclear Information System (INIS)

    Feital, J.C.

    1988-01-01

    This work shows a system to evaluate the half-value thickness of X-ray bundle. This system consists in a card with an aluminium filter, thermoluminescent dosemeter of lithium fluoride and radiographics films. )C.G.C.) [pt

  16. SU-F-T-649: Dosimetric Evaluation of Non-Coplanar Arc Therapy Using a Novel Rotating Gamma Ray System

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A; Chibani, O; Jin, L; Fan, J; Veltchev, I; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal); Li, J [Cyber Medical Inc, Xian, Shaanxi (China)

    2016-06-15

    Purpose: Stereotactic intra and extra-cranial body radiation therapy has evolved with advances in treatment accuracy, effective radiation dose, and parameters necessary to maximize machine capabilities. Novel gamma systems with a ring type gantry were developed having the ability to perform oblique arcs. The aim of this study is to explore the dosimetric advantages of this new system. Methods: The rotating Gamma system is named CybeRay (Cyber Medical Corp., Xian, China). It has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. Treatment plans were generated utilizing our in-house Monte Carlo treatment planning system. A cylindrical phantom was modeled with 2mm voxel size. Dose inside the cylindrical phantom was calculated for coplanar and non-coplanar arcs. Dosimetric differences between CybeRay cobalt beams and CyberKnife 6MV beams were compared in a lung phantom and for previously treated SBRT patients. Results: The full width at half maxima of cross profiles in the S-I direction for the coplanar setup matched the cone sizes, while for the non-coplanar setup, FWHM was larger by 2mm for a 10mm cone and about 5mm for larger cones. In the coronal and sagittal view, coplanar beams showed elliptical shaped isodose lines, while non-coplanar beams showed circular isodose lines. Thus proper selection of the oblique angle and cone size can aid optimal dose matching to the target volume. Comparing a single 5mm cone from CybeRay to that from CyberKnife showed similar penumbra in a lung phantom but CybeRay had significant lower doses beyond lung tissues. Comparable treatment plans were obtained with CybeRay as that from CyberKnife.ConclusionThe noncoplanar multiple source arrangement of CybeRay will be of great clinical benefits for stereotactic intra and extra-cranial radiation therapy.

  17. A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Alfonso, J. C. L.; Herrero, M. A.; Núñez, L.

    2015-01-01

    The choice of any radiotherapy treatment plan is usually made after the evaluation of a few preliminary isodose distributions obtained from different beam configurations. Despite considerable advances in planning techniques, such final decision remains a challenging task that would greatly benefit from efficient and reliable assessment tools. For any dosimetric plan considered, data on dose-volume histograms supplied by treatment planning systems are used to provide estimates on planning target coverage as well as on sparing of organs at risk and the remaining healthy tissue. These partial metrics are then combined into a dose distribution index (DDI), which provides a unified, easy-to-read score for each competing radiotherapy plan. To assess the performance of the proposed scoring system, DDI figures for fifty brain cancer patients were retrospectively evaluated. Patients were divided in three groups depending on tumor location and malignancy. For each patient, three tentative plans were designed and recorded during planning, one of which was eventually selected for treatment. We thus were able to compare the plans with better DDI scores and those actually delivered. When planning target coverage and organs at risk sparing are considered as equally important, the tentative plan with the highest DDI score is shown to coincide with that actually delivered in 32 of the 50 patients considered. In 15 (respectively 3) of the remaining 18 cases, the plan with highest DDI value still coincides with that actually selected, provided that organs at risk sparing is given higher priority (respectively, lower priority) than target coverage. DDI provides a straightforward and non-subjective tool for dosimetric comparison of tentative radiotherapy plans. In particular, DDI readily quantifies differences among competing plans with similar-looking dose-volume histograms and can be easily implemented for any tumor type and localization, irrespective of the planning system and

  18. Potential application of metal nanoparticles for dosimetric systems: Concepts and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, Eder José, E-mail: ederguidelli@pg.ffclrp.usp.br; Baffa, Oswaldo, E-mail: ederguidelli@pg.ffclrp.usp.br [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Av. Bandeirantes, 3900, 14040-901, Ribeirão Preto, SP (Brazil)

    2014-11-07

    Metallic nanoparticles increase the delivered dose and consequently enhance tissue radio sensitization during radiation therapy of cancer. The Dose Enhancement Factor (DEF) corresponds to the ratio between the dose deposited on a tissue containing nanoparticles, and the dose deposited on a tissue without nanoparticles. In this sense, we have used electron spin resonance spectroscopy (ESR) to investigate how silver and gold nanoparticles affect the dose deposition in alanine dosimeters, which act as a surrogate of soft tissue. Besides optimizing radiation absorption by the dosimeter, the optical properties of these metal nanoparticles could also improve light emission from materials employed as radiation detectors. Therefore, we have also examined how the plasmonic properties of noble metal nanoparticles could enhance radiation detection using optically stimulated luminescence (OSL) dosimetry. This work will show results on how the use of gold and silver nanoparticles are beneficial for the ESR and OSL dosimetric techniques, and will describe the difficulties we have been facing, the challenges to overcome, and the perspectives.

  19. Development of a dosimetric system for 90Sr + 90Y betatherapy applicators

    International Nuclear Information System (INIS)

    Coelho, Talita Salles

    2010-01-01

    The 90 Sr+ 90 Y applicators, used in betatherapy for prevention of keloids and pterigium, are imported and many times their dosimetric features are shown only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of 90 Sr+ 90 Y betatherapy applicators. The Monte Carlo code MCNP5 was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry. (author)

  20. Chilean Nuclear Energy Commission dosimetric information system; Sistema de informacion dosimetrico de la Comision Chilena de Energia Nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero Vallejos, Patricia Andrea

    1998-12-31

    This thesis discusses the nuclear radiation that people who work with radioactive material is exposed to and its control by the Chilean Nuclear Energy Commission. A full analysis of the System is presented with information about the Commission and the Department of Nuclear and Radiological Safety which runs the System. Ana analysis of the System is presented in order to obtain requirements. Management flow diagrams, the processes involved and current problems experienced by the users are described. A design logic is modeled producing Data Flow Diagrams (DFD). based on this physical design, or, Model of Physical Data, is prepared including tables, attributes, types of data, primary and foreign keys. A description is presented of how the System is implemented, the tools that are used and how the testing phase is carried out. The Dosimetry System meets the criteria for a Software Engineering project, where the basic cycle was used as a working methodology. The System developed supports the dosimetric control of people exposed to radioactive material. (author) Dissertation to obtain the degree of Computing and Informatics Engineer; 16 refs., 96 figs., 31 tabs.

  1. The dosimetric control in radiotherapy

    International Nuclear Information System (INIS)

    Veres, A.

    2009-01-01

    The author first presents the thermoluminescent dosimetry method developed by the Equal-Estro Laboratory to control radiotherapy systems, according to which dosimeters are mailed by the radiotherapy centres to the laboratory, and then analyzed with respect to the level of dose bias. In a second part, he discusses the different techniques used for the dosimetric control of new radiotherapy methods (intensity-modulated radiation therapy, tomo-therapy) for which film dosimetry is applied. He also evokes the development of new phantoms and the development of a method for the dosimetric control of proton beams

  2. SU-E-T-335: Dosimetric Investigation of An Advanced Rotating Gamma Ray System for Imaged Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Ma, C; Eldib, A; Chibani, O; Li, J; Chen, L; Li, C; Mora, G

    2015-01-01

    Purpose: Co-60 beams have unique dosimetric properties for cranial treatments and thoracic cancers. The conventional concern about the high surface dose is overcome by modern system designs with rotational treatment techniques. This work investigates a novel rotational Gamma ray system for image-guided, external beam radiotherapy. Methods: The CybeRT system (Cyber Medical Corp., China) consists of a ring gantry with either one or two treatment heads containing a Gamma source and a multileaf collimator (MLC). The MLC has 60 paired leaves, and the maximum field size is either 40cmx40cm (40 pairs of 0.5cm central leaves, 20 pairs of 1cm outer leaves), or 22cmx40cm (32 pairs of 0.25cm central leaves, 28 pairs of 0.5cm outer leaves). The treatment head(s) can swing 35° superiorly and 8° inferiorly, allowing a total of 43° non-coplanar beam incident. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV cone-beam CT system has a spatial resolution of 0.4mm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 98 previously treated patients was performed to compare CybeRT with existing RT systems. Results: Monte Carlo results confirmed the CybeRT design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient was similar to or better than that of 6MV photon beams and its isocenter accuracy is 0.3mm. Co-60 beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Because of their rapid depth dose falloff, Co-60 beams are favorable for peripheral lung tumors with half-arc arrangements to spare the opposite lung and critical structures. Superior dose distributions were obtained for head and neck, breast, spine and lung tumors. Conclusion: Because of its accurate dose delivery and unique dosimetric properties of C-60 sources, CybeRT is ideally suited for advanced SBRT as well as

  3. SU-E-T-335: Dosimetric Investigation of An Advanced Rotating Gamma Ray System for Imaged Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Eldib, A; Chibani, O; Li, J; Chen, L [Fox Chase Cancer Center, Philadelphia, PA (United States); Li, C [Renmin Hospital of Wuhan University, Wuhan (China); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2015-06-15

    Purpose: Co-60 beams have unique dosimetric properties for cranial treatments and thoracic cancers. The conventional concern about the high surface dose is overcome by modern system designs with rotational treatment techniques. This work investigates a novel rotational Gamma ray system for image-guided, external beam radiotherapy. Methods: The CybeRT system (Cyber Medical Corp., China) consists of a ring gantry with either one or two treatment heads containing a Gamma source and a multileaf collimator (MLC). The MLC has 60 paired leaves, and the maximum field size is either 40cmx40cm (40 pairs of 0.5cm central leaves, 20 pairs of 1cm outer leaves), or 22cmx40cm (32 pairs of 0.25cm central leaves, 28 pairs of 0.5cm outer leaves). The treatment head(s) can swing 35° superiorly and 8° inferiorly, allowing a total of 43° non-coplanar beam incident. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV cone-beam CT system has a spatial resolution of 0.4mm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 98 previously treated patients was performed to compare CybeRT with existing RT systems. Results: Monte Carlo results confirmed the CybeRT design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient was similar to or better than that of 6MV photon beams and its isocenter accuracy is 0.3mm. Co-60 beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Because of their rapid depth dose falloff, Co-60 beams are favorable for peripheral lung tumors with half-arc arrangements to spare the opposite lung and critical structures. Superior dose distributions were obtained for head and neck, breast, spine and lung tumors. Conclusion: Because of its accurate dose delivery and unique dosimetric properties of C-60 sources, CybeRT is ideally suited for advanced SBRT as well as

  4. 77 FR 304 - New Postal Product

    Science.gov (United States)

    2012-01-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add Priority Mail Contract 37 to the competitive product list... competitive product list.\\1\\ Priority mail [[Page 305

  5. SU-F-T-529: Dosimetric Investigation of a Rotating Gamma Ray System for ImagedGuided Modulated Arc Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Chibani, O; Eldib, A; Chen, L [Fox Chase Cancer Center, Philadelphia, PA (United States); Li, J [Cyber Medical Inc, Xian (China)

    2016-06-15

    Purpose: Because of their effectiveness and efficiency, rotational arc radiotherapy (MAT) techniques have been developed on both specialty machines such as Tomotherapy and conventional linear accelerators. This work investigates a new rotating Gamma therapy system for image guided MAT and SBRT of intra/extracranial tumors. Methods: The CyberMAT system (Cyber Medical Corp., China) consists of a ring gantry with a gamma source (effective source size 1cm and 1.7cm respectively), a 120-leaf MLC, a kV CBCT and an EPID. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV CBCT system has a spatial resolution of 0.4mm for target localization. The maximum dose rate is >4.0 Gy/min and the maximum field size is 40cm × 40cm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 125 previously treated SBRT patients was performed to evaluate the dosimetric characteristics of CyberMAT in comparison with existing VMAT systems. Results: Monte Carlo results confirmed the CyberMAT design parameters including output factors and 3D dose distributions. Its beam penumbra is 5mm to 10mm for field sizes 1cm to 10cm, respectively and its isocenter accuracy is <0.5mm. Compared to the 6 MV photons of Tomotherapy and conventional linacs, Cobalt beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Cobalt beams are ideal for peripheral lung tumors with half-arc arrangements to spare the opposite lung and other critical structures. Superior dose distributions have been obtained for brain, head and neck, breast, spine and lung tumors with half/full arc arrangements. Conclusion: Because of the unique dosimetric properties of Cobalt sources and its accurate stereotaxy/dose delivery CyberMAT is ideally suited for image guided MAT and SBRT. Full-arc arrangements are superior for brain and H&N treatments while half-arc arrangements produce best dose

  6. 78 FR 63519 - New Postal Product

    Science.gov (United States)

    2013-10-24

    ... Docket No. MC2014-1. \\1\\ Request of the United States Postal Service to Add Parcel Select and Parcel... recently-filed Postal Service request to add Parcel Select & Parcel Return Service Contract 5 to the...., the Postal Service filed a formal request and associated supporting information to add Parcel Select...

  7. 76 FR 11823 - New Postal Products

    Science.gov (United States)

    2011-03-03

    ... Postal Service filing concerning proposed changes to First-Class Mail Parcel Product offerings. These.... \\1\\ Request of the United States Postal Service Under Section 3642, February 24, 2011 (Request). The Postal Service explains that commercial First-Class Mail Parcels refers to the First-Class Mail...

  8. 77 FR 36585 - Postal Rate Changes

    Science.gov (United States)

    2012-06-19

    ... Service notice of rate and changes affecting Inbound Air Parcel Post at Universal Postal Union (UPU) rates... United States Postal Service of Filing Changes in Rates Not of General Applicability and Application for... the Postal Service's explanation of Inbound Air Parcel Post (at UPU Rates) provided in the initial...

  9. 75 FR 65675 - New Postal Product

    Science.gov (United States)

    2010-10-26

    ... United States Postal Service of Filing Canada Post Group--United States Postal Service Contractual... United States by surface transportation and Xpresspost, a Canadian service for documents, packets, and... tender surface parcels and Xpresspost to the Postal Service at negotiated prices rather than the default...

  10. 75 FR 44819 - New Postal Product

    Science.gov (United States)

    2010-07-29

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service filing to add Priority Mail Contract 27 to the competitive product list. The... to add Priority Mail Contract 27 to the competitive product list.\\1\\ The Postal Service asserts that...

  11. 75 FR 11452 - New Postal Product

    Science.gov (United States)

    2010-03-11

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Final rule. SUMMARY: The Commission is adding special postal services to the product lists. This action is consistent with changes in a postal reform law. Republication of the product lists is also consistent with a statutory provision. The Commission...

  12. 76 FR 80412 - New Postal Product

    Science.gov (United States)

    2011-12-23

    ... POSTAL REGULATORY COMMISSION Docket No. CP2012-4; Order No. 1057] New Postal Product AGENCY... Agreement within the Inbound Competitive Multi-Service Agreement with a Foreign Postal Operators 1 product... explaining why, after the change, competitive products in total will be in compliance with 39 U.S.C. 3633(a...

  13. 76 FR 67496 - New Postal Product

    Science.gov (United States)

    2011-11-01

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2012-1; Order No. 919] New Postal Product AGENCY... to the Inbound Competitive Multi-Service Agreements with Foreign Postal Operators 1 product. \\1... Operators 1 to the Competitive Product List and Approving Included Agreement, September 29, 2010 (Order No...

  14. 78 FR 37851 - New Postal Product

    Science.gov (United States)

    2013-06-24

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2013-68; Order No. 1750] New Postal Product AGENCY... filing concerning the addition of Global Expedited Package Services 3 Contract to the competitive product... GEPS 3 product. Notice at 2. \\1\\ Notice of United States Postal Service of Filing a Functionally...

  15. 75 FR 4593 - New Postal Product

    Science.gov (United States)

    2010-01-28

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2010-20; Order No. 397] New Postal Product AGENCY... Service request to add GEPS 2 (CP2009-50) to the Competitive Product List. The Postal Service has also... Global Expedited Package Services 2 to the Competitive Product List, August 28, 2009 (Order No. 290). \\4...

  16. 78 FR 76332 - New Postal Product

    Science.gov (United States)

    2013-12-17

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing recent Postal Service filings requesting the addition of Priority Mail Contract 71 to the competitive product... Contract 71 to the competitive product list.\\1\\ The Postal Service asserts [[Page 76333

  17. 77 FR 4376 - New Postal Product

    Science.gov (United States)

    2012-01-27

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add Priority Mail Contract 38 to the competitive product list... 38 to the competitive product list.\\1\\ Priority mail contracts enable the Postal Service to provide...

  18. 78 FR 13713 - New Postal Product

    Science.gov (United States)

    2013-02-28

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing concerning the addition of Express Mail Contract 14 to the competitive product list... 14 to the competitive product list.\\1\\ The Postal Service asserts that Express Mail Contract 14 is a...

  19. 77 FR 67839 - New Postal Product

    Science.gov (United States)

    2012-11-14

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing concerning the addition of Priority Mail Contract 48 to the competitive product... Mail Contract 48 to the competitive product list.\\1\\ The Postal Service indicates that the instant...

  20. 77 FR 1957 - New Postal Product

    Science.gov (United States)

    2012-01-12

    ... Postal Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently filed Postal Service request to add Global Plus 2C Contracts to the competitive product..., consisting of two Global Plus 2C agreements, to the competitive products list.\\1\\ The new product covers...

  1. 78 FR 65014 - New Postal Product

    Science.gov (United States)

    2013-10-30

    ... POSTAL REGULATORY COMMISSION [Docket No. MC2014-3 and CP2014-3; Order No. 1860] New Postal Product... competitive product list. This notice informs the public of the filing, invites public comment, and takes... Mail Express & Priority Mail Contract 15 to the competitive product list.\\1\\ The Postal Service asserts...

  2. 77 FR 2098 - New Postal Product

    Science.gov (United States)

    2012-01-13

    ... Postal Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add Global Plus 1C agreements to the competitive product... of two Global Plus 1C agreements, to the competitive product list.\\1\\ The instant agreements are set...

  3. 75 FR 7201 - New Postal Product

    Science.gov (United States)

    2010-02-18

    ... Postal Product AGENCY: Postal Regulatory Commission. ACTION: Final rule. SUMMARY: The Commission is adding Priority Mail Contract 24 to the Competitive Product List. This action is consistent with changes in a postal reform law. Republication of the lists of market dominant and competitive products is...

  4. 78 FR 79023 - New Postal Product

    Science.gov (United States)

    2013-12-27

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing requesting the addition of Priority Mail Contract 73 to the competitive product... supporting information to add Priority Mail Contract 73 to the competitive product list.\\1\\ The Postal...

  5. 78 FR 76334 - New Postal Product

    Science.gov (United States)

    2013-12-17

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2013-13; Order No. 1900] New Postal Product AGENCY...'' of the product. Id. The Postal Service seeks to incorporate by reference the Application for Non... and Order Concerning the Addition of Parcel Select Contract 6 to the Competitive Product List, October...

  6. In-phantom dosimetric measurements as quality control for brachytherapy. System check and constancy check; Messungen im Festkoerperphantom als Qualitaetskontrolle in der Brachytherapie. Systempruefung und Konstanzpruefung

    Energy Technology Data Exchange (ETDEWEB)

    Kollefrath, Michael; Bruggmoser, Gregor; Nanko, Norbert; Gainey, Mark [Universitaetsklinik Freiburg (Germany). Klinik fuer Strahlenheilkunde

    2015-09-01

    In brachytherapy dosimetric measurements are difficult due to the inherent dose-inhomogeneities. Typically in routine clinical practice only the nominal dose rate is determined for computer controlled afterloading systems. The region of interest lies close to the source when measuring the spatial dose distribution. In this region small errors in the positioning of the detector, and its finite size, lead to large measurement uncertainties that exacerbate the routine dosimetric control of the system in the clinic. The size of the measurement chamber, its energy dependence, and the directional dependence of the measurement apparatus are the factors which have a significant influence on dosimetry. Although ionisation chambers are relatively large, they are employed since similar chambers are commonly found on clinical brachytherapy units. The dose is determined using DIN 6800 [11] since DIN 6809-2 [12], which deals with dosimetry in brachytherapy, is antiquated and is currently in the process of revision. Further information regarding dosimetry for brachytherapy can be found in textbooks [1] and [2]. The measurements for this work were performed with a HDR (High-Dose-Rate) {sup 192}Ir source, type mHDR V2, and a Microselectron Afterloader V2 both from Nucletron/Elekta. In this work two dosimetric procedures are presented which, despite the aforemention difficulties, should assist in performing checks of the proper operation of the system. The first is a system check that measures the dose distribution along a line and is to be performed when first bringing the afterloader into operation, or after significant changes to the system. The other is a dosimetric constancy check, which with little effort can be performed monthly or weekly. It simultaneously verifies the positioning of the source at two positions, the functionality of the system clock and the automatic re-calculation of the source activity.

  7. 76 FR 55619 - Performance Measurement for Special Postal Services

    Science.gov (United States)

    2011-09-08

    ..., Corporate & Postal Business Law, United States Postal Service to Shoshana M. Grove, Secretary, Postal... & Postal Business Law, United States Postal Service. III. Background of Postal Service Proposals A...), Public Law 109-435, 120 Stat. 3198 (2006). The proposed rules described herein would establish reporting...

  8. 39 CFR 211.2 - Regulations of the Postal Service.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Regulations of the Postal Service. 211.2 Section 211.2 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION APPLICATION OF REGULATIONS § 211.2 Regulations of the Postal Service. (a) The regulations of the Postal Service consist of...

  9. 39 CFR 221.1 - The United States Postal Service.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false The United States Postal Service. 221.1 Section 221.1 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION GENERAL ORGANIZATION § 221.1 The United States Postal Service. The United States Postal Service was established as an...

  10. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V.

    1998-01-01

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  11. Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Hardev; De La Fuente Herman, Tania; Showalter, Barry; Thompson, Spencer J.; Syzek, Elizabeth J.; Herman, Terence; Ahmad, Salahuddin [Department of Radiation Oncology, Peggy and Charles Stephenson Oklahoma Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104 (United States)

    2012-10-23

    This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

  12. 3-D dosimetric evaluation of 2.5 mm HD120 multileaf system for intensity modulated stereotactic radiosurgery using optical CT based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Wuu, C-S; Kessel, Jack; Xu, Y

    2009-01-01

    A Trilogy TX equipped with a 2.5 mm HD120 multileaf collimator system is available for the treatment of radiosurgery and IMRT. In this study, we evaluated the 3-D dosimetric impact of leaf width on an IMRT radiosurgery plan by comparing the target coverage and the dose gradient around the target, produced from both a 2.5 mm HD120 high-definition MLC system and a 5mm-leaf-width millennium 120 MLC system, using an optical CT based polymer gel dosimetry system. The 2.5 mm MLC improves target conformity and surrounding tissue sparing when compared to that of 5 mm MLC.

  13. SU-F-J-129: Verification of Geometric and Dosimetric Accuracy of Respiratory Management Systems Using Homemade Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Goksel, E; Kucucuk, H; Senkesen, O [Acibadem Kozyatgi Hospital, Istanbul (Turkey); Tezcanli, E [Acibadem University, Istanbul (Turkey)

    2016-06-15

    Purpose: Different placements of Infrared Cameras (IRC) in CT and treatment rooms can cause gating window level (GWL) variations leading to differences between GWL used for planning and treatments. Although, Varian Clinac DHX-OBI sytem and CT are equipped with the same kind of IRC, Truebeam STx (TB) has a different type of IRC known as banana type. In this study; geometric and dosimetric accuracy of respiratory management system (RPM) for different machines were investigated with a special homemade phantom. Methods: Special phantom was placed on the respiratory simulator machine and a CT data set was obtained at the end of the expirium phase (EOE). Conformal and IMRT plans were generated on the EOE CT image series for both DHX-OBI and TB LINACs while a VMAT plan was generated only for TB.The acquired respiratory graphs in the CT were directly sent to DHX-OBI system, and they were converted with software before sending to TB. EBT3 films were placed inside the phantom and were irradiated using RPM system with two machines for different plans. Planar dose distributions were compared with gamma analysis (GA) method (3mm, %3) to evaluate planned-measured dose differences. In addition, radio-opac marker was placed in the center of the phantom to evaluate the geometric accuracy of treatment field with gated flouroscopy (GF). Results: There were no shifts detected between planning and treeatment GWL for both DHX-OBI and TB. Difference on the GF image between digital graticule and radio-opac marker was <1mm for TB and 1mm for DHX-OBI. Although, GA agreement was 97% for conformal and IMRT techniques in TB, it was 96% for VMAT technique. While GA agreement was 98% for conformal technique in DHX-OBI, IMRT was 95%.ConclusionThis study showed that RPM can be used accurately in spite of different IRC placements or different types of ICR used.

  14. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G.

    2006-01-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  15. A Method of Postal Audit in Dental Radiodiagnostics

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Novak, L.

    2001-01-01

    Full text: The National Radiation Protection Institute (NRPI) develops a new method for independent control of radiodiagnostic dental intraoral units for purposes of state supervision. The method is aimed to check not only basic dosimetric characteristics of the unit, but also conditions of developing process used by dentists. It is considered as a postal audit. The dosimetric part of the method includes irradiation of a radiographic film along with an attached TLD in order to check Ka output, field size and exposition reproducibility. The developing process is checked by means of dental films and a standardised dental phantom. The dentist is asked to develop a dental film irradiated under reference conditions by NRPI, and on the other hand to irradiate his own dental film using the phantom, that will be developed later by NRPI. Comparison of both the dental films provides information about developing process quality. It also indicates a relation between applied Ka and developing process at the place. The method is supposed to simplify the state supervision operation in the field of dental radiodiagnostics. (author)

  16. Novel Approaches to Improve the Combined Geometric and Dosimetric Performance of Existing IG-IMRT Systems

    International Nuclear Information System (INIS)

    Jaffray, D A; Sharpe, M; Rink, A; Letourneau, D

    2010-01-01

    The development of image-guidance technologies offer increased precision and accuracy in the placement of radiation therapy dose distributions in the human body. Kilovoltage and megavoltage systems now offer sub-mm accuracy and precision in localizing the treatment and planned isocenters. While this represents a significant improvement in our ability to target lesions, the performance of these systems in terms of their precise and accurate placement of field edges, including individual multi-leaves, is not performing at the same level. The development of dosimeters with small, imageable regions of response will allow these new systems to be evaluated with a much higher level of precision and accuracy. Furthermore, the development of completely automated systems that exploit the robotic nature of the imaging and delivery subsystems should permit the true performance of current IG-IMRT systems to be realized, quantified, and monitored. This includes adjustments to the treatment machines operating parameters, as well as, refinements of the planning system's beam model. Specifically, investigations into novel approaches of employing these detectors, automating their use to maximize system performance, and, the development of novel detectors for compatibility in MR-based systems will be discussed.

  17. Development of a three-dimensionally movable phantom system for dosimetric verifications

    International Nuclear Information System (INIS)

    Nakayama, Hiroshi; Mizowaki, Takashi; Narita, Yuichiro; Kawada, Noriyuki; Takahashi, Kunio; Mihara, Kazumasa; Hiraoka, Masahiro

    2008-01-01

    The authors developed a three-dimensionally movable phantom system (3D movable phantom system) which can reproduce three-dimensional movements to experimentally verify the impact of radiotherapy treatment-related movements on dose distribution. The phantom system consists of three integrated components: a three-dimensional driving mechanism (3D driving mechanism), computer control system, and phantoms for film dosimetry. The 3D driving mechanism is a quintessential part of this system. It is composed of three linear-motion tables (single-axis robots) which are joined orthogonally to each other. This mechanism has a motion range of 100 mm, with a maximum velocity of 200 mm/s in each dimension, and 3D motion ability of arbitrary patterns. These attributes are sufficient to reproduce almost all organ movements. The positional accuracy of this 3D movable phantom system in a state of geostationary is less than 0.1 mm. The maximum error in terms of the absolute position on movement was 0.56 mm. The positional reappearance error on movement was up to 0.23 mm. The observed fluctuation of time was 0.012 s in the cycle of 4.5 s of oscillation. These results suggested that the 3D movable phantom system exhibited a sufficient level of accuracy in terms of geometry and timing to reproduce interfractional organ movement or setup errors in order to assess the influence of these errors on high-precision radiotherapy such as stereotactic irradiation and intensity-modulated radiotherapy. In addition, the authors 3D movable phantom system will also be useful in evaluating the adequacy and efficacy of new treatment techniques such as gating or tracking radiotherapy

  18. Dosimetric characterization of the Exradin W1 plastic scintillator detector through comparison with an in-house developed scintillator system. / Beierholm, Anders Ravnsborg

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, Claus Flensted; Andersen, Claus E.

    2014-01-01

    method, but differing primarily in the signal detection hardware. The two systems were compared with respect to essential dosimetric properties, with the purpose of testing their performance under conditions less well discussed in the literature. A Farmer ionization chamber was used as the primary...... is therefore advised if using either system for measurements in large fields or under circumstances where the fibre irradiation geometry is unfavourable. Measurements of reference dose to water yielded differences up to 1.5% when compared with the Farmer ionization chamber for all investigated beam qualities....

  19. Development of a dosimetric system for the quality control of breast cancer treatments

    International Nuclear Information System (INIS)

    Chaves, Roberio C.; Crispim, Verginia R.; Santos, Delano B.V.

    2013-01-01

    A system for evaluating the values of absorbed dose in breast teletherapy was developed, using thermoluminescent dosimeters (TLD-100), to compare them to those provided by Therapy planning system. A breast phantom was made to distribute the dosimeters TL shaped chip in breast volume and irradiate it under the same conditions of planning. Three different techniques of teletherapy were considered: one with irradiation from a therapy unit of 60 Co and two with an X-ray beam coming from a 6 MV linear accelerator. Doses measures allowed checking that the performance of the quality control system used in breast cancer treatment is appropriate, since the planned doses differed about 1.5% of the responses provided by TL dosimeters

  20. The Role of Influence Factors on the Performance of Dosimetric Systems

    International Nuclear Information System (INIS)

    Kovacs, A.

    2007-01-01

    Quality control has to be based on the assurance that the process was carried out within prescribed dose limits. This requires proper use and selection of dosimetry system. Selection criteria: according to the process to be controlled (i.e. dose range); and according to dosimeter characteristics are shown

  1. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    International Nuclear Information System (INIS)

    Nalichowski, Adrian; Eagle, Don G.; Burmeister, Jay

    2016-01-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  2. Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system

    International Nuclear Information System (INIS)

    Li, X. Allen; Stepaniak, Christopher; Gore, Elizabeth

    2006-01-01

    This work introduces a gating technique that uses 4DCT to determine gating parameters and to plan gated treatment, and employs a Siemens linear accelerator to deliver the gated treatment. Because of technology incompatibility, the 4DCT scanner (LightSpeed, GE) and the Siemens accelerator require two different motion-monitoring systems. The motion monitoring system (AZ-773V, Anzai Med.) used for the gated delivery utilizes a pressure sensor to detect the external respiratory motion (pressure change) in real time. Another system (RPM, Varian) used for the 4DCT scanner (LightSpeed, GE) is based on an infrared camera to detect motion of external markers. These two motion monitoring systems (RPM and Anzai systems) were found to correlate well with each other. The depth doses and profile measured for gated delivery (with a duty cycle of 25% or 50%) were found to agree within 1.0% with those measured for ungated delivery, indicating that gating did not significantly alter beam characteristics. The measurement verified also that the MU linearity and beam output remained unchanged (within 0.3%). A practical method of using 4DCT to plan a gated treatment was developed. The duty cycle for either phase or amplitude gating can be determined based on 4DCT with consideration of set-up error and delivery efficiency. The close-loop measurement involving the entire gating process (imaging, planning, and delivery) showed that the measured isodose distributions agreed with those intended, validating the accuracy and reliability of the gating technique. Based these observations, we conclude that the gating technique introduced in this work, integrating Siemens linear accelerator and Anzai pressure sensor device with GE/Varian RPM 4DCT, is reliable and effective, and it can be used clinically to account for respiratory motion during radiation therapy

  3. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nalichowski, Adrian, E-mail: nalichoa@karmanos.org [Karmanos Cancer Center, Detroit, MI (United States); Eagle, Don G. [Wayne State University School of Medicine, Detroit, MI (United States); Burmeister, Jay [Karmanos Cancer Center, Detroit, MI (United States); Wayne State University School of Medicine, Detroit, MI (United States)

    2016-10-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  4. Dosimetric and QA aspects of Konrad inverse planning system for commissioning intensity-modulated radiation therapy

    Directory of Open Access Journals (Sweden)

    Deshpande Shrikant

    2007-01-01

    Full Text Available The intensity-modulated radiation therapy (IMRT planning is performed using the Konrad inverse treatment planning system and the delivery of the treatment by using Siemens Oncor Impression Plus linear accelerator (step and shoot, which has been commissioned recently. The basic beam data required for commissioning the system were generate. The quality assurance of relative and absolute dose distribution was carried out before clinical implementation. The salient features of Konrad planning system, like dependence of grid size on dose volume histogram (DVH, number of intensity levels and step size in sequencer, are studied quantitatively and qualitatively. To verify whether the planned dose [from treatment planning system (TPS] and delivered dose are the same, the absolute dose at a point is determined using CC01 ion chamber and the axial plane dose distribution is carried out using Kodak EDR2 in conjunction with OmniPro IMRT Phantom and OmniPro IMRT software from Scanditronix Wellhofer. To obtain the optimum combination in leaf sequencer module, parameters like number of intensity levels, step size are analyzed. The difference between pixel values of optimum fluence profile and the fluence profile obtained for various combinations of number of intensity levels and step size is compared and plotted. The calculations of the volume of any RT structure in the dose volume histogram are compared using grid sizes 3 mm and 4 mm. The measured and planned dose at a point showed good agreement (< 3% except for a few cases wherein the chamber was placed in a relatively high dose gradient region. The axial plane dose distribution using film dosimetry shows excellent agreement (correlation coefficient> 0.97 in all the cases. In the leaf sequencer module, the combination of number of intensity level 7 with step size of 3 is the optimal solution for obtaining deliverable segments. The RT structure volume calculation is found to be more accurate with grid size of

  5. Evolution of dosimetric phantoms

    International Nuclear Information System (INIS)

    Reddy, A.R.

    2010-01-01

    In this oration evolution of the dosimetric phantoms for radiation protection and for medical use is briefly reviewed. Some details of the development of Indian Reference Phantom for internal dose estimation are also presented

  6. Development of a computational system based in the code GEANT4 for dosimetric evaluation in radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, Alex Cristovao Holanda de

    2016-01-01

    The incidence of cancer has grown in Brazil, as well as around the world, following the change in the age profile of the population. One of the most important techniques and commonly used in cancer treatment is radiotherapy. Around 60% of new cases of cancer use radiation in at least one phase of treatment. The most used equipment for radiotherapy is a linear accelerator (Linac) which produces electron or X-ray beams in energy range from 5 to 30 MeV. The most appropriate way to irradiate a patient is determined during treatment planning. Currently, treatment planning system (TPS) is the main and the most important tool in the process of planning for radiotherapy. The main objective of this work is to develop a computational system based on the MC code Geant4 for dose evaluations in photon beam radiotherapy. In addition to treatment planning, these dose evaluations can be performed for research and quality control of equipment and TPSs. The computer system, called Quimera, consists of a graphical user interface (qGUI) and three MC applications (qLinacs, qMATphantoms and qNCTphantoms). The qGUI has the function of interface for the MC applications, by creating or editing the input files, running simulations and analyzing the results. The qLinacs is used for modeling and generation of Linac beams (phase space). The qMATphantoms and qNCTphantoms are used for dose calculations in virtual models of physical phantoms and computed tomography (CT) images, respectively. From manufacturer's data, models of a Varian Linac photon beam and a Varian multileaf collimator (MLC) were simulated in the qLinacs. The Linac and MLC modelling were validated using experimental data. qMATphamtoms and qNCTphantoms were validated using IAEA phase spaces. In this first version, the Quimera can be used for research, radiotherapy planning of simple treatments and quality control in photon beam radiotherapy. The MC applications work independent of the qGUI and the qGUI can be used for

  7. Enable dosimetric of the Stereotactic Body Frame from Elekta in treatment planning systems for Radiotherapy

    International Nuclear Information System (INIS)

    Gonzalez Perez, Y.; Caballero Pinelo, R.; Alfonso Laguardia, R.

    2015-01-01

    The purpose of this study is to evaluate the commissioning of a stereotactic body frame (SBF ® , Elekta) professional treatment planning systems (TPS) model Elekta's PrecisePlan ® and ERGO++®, for highly foxused delivery of megavoltage photon beams intended for treating tumors located in the thorax and abdominal region. For this purpose we applicated a dedicate stereotactic body frame (SBF ® , Elekta) intended for high precision radiotherapy in extra-cranial located tumors was studied. Issues associated with their implementation in the TPSs were evaluated comparing the dose calculations in two studies of CT under different conditions. an anthropomorphic thorax phantom, model CIRS Thorax IMRT ® , was used in designing several test cases. Ion chamber measurement was permormed in selected points in the phantom, for comparison purposes with dose calculated by the treatment planning systems. The commissioning of the stereotactic body frame (SBF ® , Elekta) and the stereotactic localization was verified, including the dose calculation verification in presence the SBF. The attenuation factors measured for the SBF were obtained and corrected in the TPS PrecisePlan ® , the biggest discrepancies obtained were ∼5% for the oblique sectors (inferior corners), because the minimum permissible value for the software is 0.95 while the real value measured was 0.898. It was studied the SBF, their components and their interference in depth with the photon beams and their implementation in the TPS. The introduction of the correction factors demonstrated to be effective to reduce the eventual errors of dose calculation in the TPS . (Author)

  8. 75 FR 72846 - New Postal Product

    Science.gov (United States)

    2010-11-26

    ...\\ Request of the United States Postal Service to Add Parcel Return Service Contract 2 to the Competitive... recently-filed Postal Service request to add Parcel Return Service Contract 2 to the competitive product... Service filed a formal request and associated supporting information to add Parcel Return Service Contract...

  9. 75 FR 3383 - New Postal Product

    Science.gov (United States)

    2010-01-21

    ... is adding Express Mail Contract 7 to the Competitive Product List. This action is consistent with a postal reform law. Republication of the lists of market dominant and competitive products is also.... Introduction The Postal Service seeks to add a new product identified as Express Mail [[Page 3384

  10. 75 FR 65533 - New Postal Product

    Science.gov (United States)

    2010-10-25

    ... consideration of the Request pertaining to the proposed Express Mail Contract 9 product and the related contract...-filed Postal Service filing to add Express Mail Contract 9 to the competitive product list. The Postal Service has also filed a related contract. This notice addresses procedural steps associated with the...

  11. 75 FR 65532 - New Postal Product

    Science.gov (United States)

    2010-10-25

    .... MC2011-2 and CP2011-3 for consideration of the Request pertaining to the proposed Priority Mail Contract...-filed Postal Service filing to add Priority Mail Contract 28 to the competitive product list. The Postal Service has also filed a related contract. This notice addresses procedural steps associated with the...

  12. 75 FR 12805 - New Postal Product

    Science.gov (United States)

    2010-03-17

    ... Docket No. CP2010-26 for consideration of matters related to the contract identified in the Postal... Service request to include a new contract within the existing Global Expedited Package Services 2 (GEPS 2) product. The Postal Service characterizes the referenced contract as a successor to a current contract...

  13. 75 FR 65531 - New Postal Product

    Science.gov (United States)

    2010-10-25

    .... MC2011-3 and CP2011-4 for consideration of the Request pertaining to the proposed Priority Mail Contract...-filed Postal Service filing to add Priority Mail Contract 29 to the competitive product list. The Postal Service has also filed a related contract. This notice addresses procedural steps associated with the...

  14. 76 FR 25381 - Postal Service Market Test

    Science.gov (United States)

    2011-05-04

    ... POSTAL REGULATORY COMMISSION [Docket No. MT2009-4; Order No. 720] Postal Service Market Test... test, pending Commission action on anticipated request for permanent status. This document grants a one... temporarily extend its Collaborative Logistics market test under 39 U.S.C. 3641(d).\\1\\ The Commission...

  15. 76 FR 67500 - Postal Service Price Adjustment

    Science.gov (United States)

    2011-11-01

    ... available data from the Bureau of Labor Statistics provides the Postal Service with inflation-based price... includes a brief introductory section, three enumerated parts, and three attachments. The Postal Service also submitted separate workpapers supporting the planned changes. The introductory section includes...

  16. 76 FR 52718 - Complaint About Postal Services

    Science.gov (United States)

    2011-08-23

    ... Pleadings III. Statutory Alternatives for Commission Action IV. Analysis and Written Determination V....C. 403(c). Id. at 12. II. Postal Service Pleadings On June 7, 2011, the Postal Service filed a...)(1)(B). \\8\\ The statute does not specify the precise nature of the proceedings. IV. Analysis and...

  17. 77 FR 67840 - New Postal Product

    Science.gov (United States)

    2012-11-14

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent... competitive product list. This notice informs the public of the filing, invites public comment, and takes... to add First-Class Package Service Contract 26 to the competitive product list.\\1\\ The Postal Service...

  18. 77 FR 58185 - New Postal Product

    Science.gov (United States)

    2012-09-19

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2012-56; Order No. 1464] New Postal Product AGENCY... Service request to add a Global Expedited Package Services contract to the competitive product list. This... contracts are small- or medium-size businesses that mail products directly to foreign destinations using...

  19. 77 FR 58422 - New Postal Product

    Science.gov (United States)

    2012-09-20

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add Priority Mail Contract 43 to the competitive product list... request and associated supporting information to add Priority Mail Contract 43 to the competitive product...

  20. 75 FR 45176 - New Postal Product

    Science.gov (United States)

    2010-08-02

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add Priority Mail Contract 25 to the competitive product list. The... associated supporting information to add Priority Mail Contract 25 to the competitive product list.\\1\\ The...

  1. 78 FR 40203 - New Postal Product

    Science.gov (United States)

    2013-07-03

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add a new product to the competitive product list. This document... Rate Boxes--Non-Published Rates (PMI RRB-NPR) to the competitive product list.\\1\\ It provides a related...

  2. 77 FR 50729 - New Postal Product

    Science.gov (United States)

    2012-08-22

    ... POSTAL REGULATORY COMMISSION [Docket Nos. MC2012-44; Order No. 1435] New Postal Product AGENCY... Service request for two related changes to the product lists. The changes involve removing one product from the market dominant product list and adding a nearly identical product to the competitive product...

  3. 77 FR 60727 - New Postal Product

    Science.gov (United States)

    2012-10-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... competitive product list.\\1\\ The Postal Service asserts that First- Class Package Service Contract 20 is a...

  4. 78 FR 43245 - New Postal Product

    Science.gov (United States)

    2013-07-19

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing concerning the addition of Priority Mail Contract 61 to the competitive product... the competitive product list.\\1\\ It asserts that Priority Mail Contract 61 is a competitive product...

  5. 78 FR 4478 - New Postal Product

    Science.gov (United States)

    2013-01-22

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2013-42; Order No. 1623] New Postal Product AGENCY... within the Global Plus 2C product on the grounds of functional equivalence to previously approved.... Id. at 1. Background. The Commission added Global Plus 2 to the competitive product list, based on...

  6. 78 FR 26405 - New Postal Product

    Science.gov (United States)

    2013-05-06

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing concerning the addition of Priority Mail Contract 58 to the competitive product... 58 to the competitive product list.\\1\\ It asserts that Priority Mail Contract 58 is a competitive...

  7. 78 FR 29784 - New Postal Product

    Science.gov (United States)

    2013-05-21

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2013-62; Order No. 1716] New Postal Product AGENCY... filing concerning the addition of Global Expedited Package Services 3 Contract to the competitive product... GEPS 3 product on grounds of functional equivalence to a previously approved baseline agreement. Id. at...

  8. 77 FR 60726 - New Postal Product

    Science.gov (United States)

    2012-10-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... 19 to the competitive product list.\\1\\ The Postal Service asserts that First- Class Package Service...

  9. 78 FR 963 - New Postal Product

    Science.gov (United States)

    2013-01-07

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent... 4 to the competitive product list. This notice informs the public of the filing, invites public... product list.\\1\\ The Postal Service states that the addition is necessary due to changes in the non...

  10. 77 FR 60725 - New Postal Product

    Science.gov (United States)

    2012-10-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... competitive product list.\\1\\ The Postal Service asserts that First- Class Package Service Contract 16 is a...

  11. 75 FR 7296 - New Postal Product

    Science.gov (United States)

    2010-02-18

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2010-23; Order No. 405] New Postal Product AGENCY... Service request to add a Global Expedited Package Services 2 contract to the Competitive Product List... established GEPS 1 as a product, also authorized functionally equivalent agreements to be included within the...

  12. 78 FR 13714 - New Postal Product

    Science.gov (United States)

    2013-02-28

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing concerning the addition of Priority Mail Contract 55 to the competitive product... 55 to the competitive product list.\\1\\ It asserts that Priority Mail Contract 55 is a competitive...

  13. 77 FR 60729 - New Postal Product

    Science.gov (United States)

    2012-10-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... competitive product list.\\1\\ The Postal Service asserts that First- Class Package Service Contract 17 is a...

  14. 78 FR 70084 - New Postal Product

    Science.gov (United States)

    2013-11-22

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent Postal Service filing concerning the addition of Priority Mail Contract 65 to the competitive product... information to add Priority Mail Contract 65 to the competitive product list.\\1\\ It asserts that Priority Mail...

  15. 75 FR 45174 - New Postal Product

    Science.gov (United States)

    2010-08-02

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... competitive product list. The Postal Service has also filed a related contract. This notice addresses... product list within the Mail Classification Schedule (MCS).\\1\\ This product grouping would create a niche...

  16. 78 FR 79022 - New Postal Product

    Science.gov (United States)

    2013-12-27

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent... product list. This notice informs the public of the filing, invites public comment, and takes other... Mail Express Contract 16 to the competitive product list.\\1\\ The Postal Service asserts that Priority...

  17. 78 FR 65016 - New Postal Product

    Science.gov (United States)

    2013-10-30

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing recent Postal Service filings requesting the addition of Priority Mail Contract 66 to the competitive product... Contract 66 to the competitive product list.\\1\\ It is the successor agreement to the contract approved in...

  18. 77 FR 58421 - New Postal Product

    Science.gov (United States)

    2012-09-20

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add Priority Mail Contract 42 to the competitive product list... request and associated supporting information to add Priority Mail Contract 42 to the competitive product...

  19. 77 FR 60728 - New Postal Product

    Science.gov (United States)

    2012-10-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... competitive product list.\\1\\ The Postal Service asserts that First- Class Package Service Contract 18 is a...

  20. 77 FR 1089 - New Postal Product

    Science.gov (United States)

    2012-01-09

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2012-9; Order No. 1096] New Postal Product AGENCY... Service request to add a Global Direct Contracts 1 contract to the competitive product list. This notice... believes that the instant Agreement should be included within the Global Direct Contracts 1 product because...

  1. 77 FR 305 - New Postal Product

    Science.gov (United States)

    2012-01-04

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... competitive product list. This notice addresses procedural steps associated with the filing. DATES: Comments... Services-Non- Published Rates 3 (GEPS-NPR 3) to the competitive product list.\\1\\ The Postal [[Page 306...

  2. 76 FR 4138 - New Postal Product

    Science.gov (United States)

    2011-01-24

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2011-58; Order No. 652] New Postal Product AGENCY..., which established GREP Contracts 1 as a product, also authorized functionally equivalent agreements to be included within the product, provided that they meet the requirements of 39 U.S.C. 3633. Id. at 1...

  3. 77 FR 51583 - New Postal Product

    Science.gov (United States)

    2012-08-24

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... competitive product list.\\1\\ The Postal Service asserts that First- Class Package Service Contract 15 is a...

  4. 75 FR 65386 - New Postal Product

    Science.gov (United States)

    2010-10-22

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2011-19; Order No. 562] New Postal Product AGENCY... product list. This notice addresses procedural steps associated with this filing. DATES: Comments are due... GEPS 1 as a product, also authorized functionally equivalent agreements to be included within the...

  5. 78 FR 39783 - New Postal Product

    Science.gov (United States)

    2013-07-02

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recently-filed Postal Service request to add a new product to the competitive product list. This document... and associated supporting information to add Priority Mail Contract 60 to the competitive product list...

  6. 78 FR 59382 - New Postal Product

    Science.gov (United States)

    2013-09-26

    ... relevant to the customer's mailing profile, and cost coverage projections. Id. The Postal Service asks the... recently-filed Postal Service request to add a new product to the competitive product list. This document... due: September 27, 2013. ADDRESSES: Submit comments electronically by accessing the ``Filing Online...

  7. 77 FR 2676 - Competitive Postal Products

    Science.gov (United States)

    2012-01-19

    ... could give the Postal Service an artificial competitive advantage. The Commission gave considerable... POSTAL REGULATORY COMMISSION 39 CFR Part 3015 [Docket No. RM2012-3; Order No. 1108] Competitive... Commission is initiating a review to determine whether competitive products provide the appropriate minimum...

  8. 75 FR 34074 - Postal Pricing Methods

    Science.gov (United States)

    2010-06-16

    ... Methods AGENCY: Postal Regulatory Commission. ACTION: Notice of proposed rulemaking. SUMMARY: The... price sensitivity (elasticity) to volumes actually mailed during the rebate program. This method is... indicated by the market elasticity. Mitchell Comments at 4-6. Postal Service method. In its data collection...

  9. 78 FR 77172 - New Postal Product

    Science.gov (United States)

    2013-12-20

    ... Counsel, at 202-789-6820. SUPPLEMENTARY INFORMATION: Table of Contents I. Introduction II. Contents of Filing III. Commission Action IV. Ordering Paragraphs I. Introduction On December 13, 2013, the Postal..., 3. II. Contents of Filing The Postal Service's filing consists of the Notice, financial workpapers...

  10. 77 FR 27491 - New Postal Product

    Science.gov (United States)

    2012-05-10

    ..., April 30, 2012 (Request). Request. In support of its Request, the Postal Service filed six attachments... exceed 85 percent of the total volume of pieces mailed. Id. Valassis has agreed to initiate mailings... 1,000,000 pieces during the following 12 months or pay the Postal Service a one-time fee of $100,000...

  11. 75 FR 9523 - New Postal Product

    Science.gov (United States)

    2010-03-03

    ... obligations or new requirements on any party to the contract. The docket referenced in the caption should be... adding Global Direct Contracts 1 to the Competitive Product List. This action is consistent with a postal.... Introduction The Postal Service seeks to add a new product identified as Global Direct Contracts 1 to the...

  12. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit.

    Science.gov (United States)

    Rutonjski, Laza; Petrović, Borislava; Baucal, Milutin; Teodorović, Milan; Cudić, Ozren; Gershkevitsh, Eduard; Izewska, Joanna

    2012-09-12

    Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.

  13. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit

    International Nuclear Information System (INIS)

    Rutonjski, Laza; Petrović, Borislava; Baucal, Milutin; Teodorović, Milan; Čudić, Ozren; Gershkevitsh, Eduard; Izewska, Joanna

    2012-01-01

    Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable

  14. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit

    Directory of Open Access Journals (Sweden)

    Rutonjski Laza

    2012-09-01

    Full Text Available Abstract Background Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. Methods The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs. The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. Results The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. Conclusions The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.

  15. The dosimetric properties of phosphate glass systems prepared by different chemical nanomaterials.

    Science.gov (United States)

    Abdelhalim, Mohamed Anwar K; Al-Shamrani, Bandar Mora

    2016-12-01

    The synthesis and characterization of glass systems were carried out using prepared nanocrystals injected into a glass matrix as a thermoluminescence (TL) activator using the melt-quenching method. Sample 1 was prepared as [40P 2 O 5 50BaO:2.5MgO, 2.5Na 2 O, 5TiO 2 ], sample 2 as [37.5P 2 O 5 37.5CaO:25TiO 2 ] and sample 3 as [50P 2 O 5 -50Li 2 O]. Formation of the synthesized compound was confirmed by studying the X-ray diffraction (XRD) patterns and scanning electron microscopy (SEM) images. An annealing procedure was carried out for 1 h at 400 °C. The glow curve position and shape shifted dramatically and linearly to the higher temperature values on increasing the heating rate. A heating rate of 30 °C/s was the most suitable for obtaining a high TL response. Samples 2 and 3 have the highest TL response, which approached the effective atomic number (Z eff ) of natural bone. The observed TL sensitivity of the prepared samples 2 and 3 is less than that of commercially available 'TLD-200 chips' and LiF:Mg,Ti (TLD-100) phosphor. Sample [37.5P 2 O 5 37.5CaO:25TiO 2 ] would be useful in personal and environmental dosimetry for measuring high doses of gamma radiation. Sample [50P 2 O 5 -50Li 2 O] is a good dosimeter, although it requires the addition of an appropriate transitional metal (activator) to overcome the problem of high fading. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. MO-FG-BRA-01: Development of An Image-Guided Dosimetric Planning System for Injectable Brachytherapy Using ELP Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Lafata, K [Duke University, Durham, North Carolina (United States); Duke University Medical Center, Durham, NC (United States); Schaal, J; Liu, W [Duke University, Durham, North Carolina (United States); Cai, J [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To develop, validate, and evaluate a methodology for determining dosimetry for intratumoral injections of elastin-like-polypeptide (ELP) brachytherapy nanoparticles. These organic-polymer-based nanoparticles are injectable, biodegradable, and genetically tunable. We present a genetically encoded polymer-solution, composed of novel radiolabeled-ELP nanoparticles that are custom-designed to self-assemble into a local source upon intratumoral injection. Our preliminary results of a small animal study demonstrate 100% tumor response, effective radionuclide retention-rates, strong in vivo stability, and no polymer-induced toxicities. While our approach is therefore highly promising for improved brachytherapy, the current workflow lacks a dosimetry framework. Methods: We are developing a robust software framework that provides image-guided dosimetric-planning capabilities for ELP brachytherapy. The user graphically places ELP injection sites within a µCT-planning-image, and independently defines each injection volume, concentration, and radioisotope to be used. The resulting internal dosimetry is then pre-determined by first modeling post-injection ELP advection-diffusion, and then calculating the resulting dose distribution based on a point- dose-kernel-convolution algorithm. We have experimentally measured ELP steady-state concentrations via µSPECT acquisition, and validated our dose calculation algorithm against Monte Carlo simulations of several radioactivity distributions. Finally, we have investigated potential advantages and limitations of various ELP injection parameters. Results: The µSPECT results demonstrated inhomogeneous steady-state distributions of ELP in tissue, and Monte Carlo radioactivity distributions were designed accordingly. Our algorithm yielded a root-mean-square-error of less than 2% for each distribution tested (average root-mean-square-error was 0.73%). Dose-Volume-Histogram analysis of five different plans showed how strategic

  17. Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service

    International Nuclear Information System (INIS)

    Jangda, A.Q.; Hussein, S.

    2012-01-01

    In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility. (author)

  18. Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service.

    Science.gov (United States)

    Jangda, Abdul Qadir; Hussein, Sherali

    2012-05-01

    In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility.

  19. Digital transformation, business models and the postal industry

    OpenAIRE

    Kollara, Nandkumar Harshan

    2017-01-01

    For many decades, the postal industry offered postal services and in parallel, had a monopoly over the national postal markets. Recently, the postal industry endured a phase where their national postal markets were subjected to liberalisation by the respective nations. This was due to various reasons such as inefficiencies of the postal services, ambiguous monopoly legislations, mounting pressure from competitors, and changing nature of customer demands. The liberalisation of the European Uni...

  20. Non-dosimetric quality assurance for the three-dimensional radiation treatment planning systems using a multi-leaf collimator phantom

    International Nuclear Information System (INIS)

    Tateoka, Kunihiko; Nagase, Daiki; Sato, Takahito; Shimizume, Kazunari; Ouchi, Atsushi; Nakata, Kensei; Hareyama, Masato

    2008-01-01

    Evaluation of errors and limitations in simulation software for three-dimensional radiation treatment systems (3D-RTPS) is an important issue. Non-dosimetric quality assurance (QA) of the simulation software of 3D-RTPS was evaluated by graphical displays of JAW and multi-leaf collimator (MLC) settings in a 3D-RTPS. The influence of observations made using the phantom depends on human errors and several parameters of the CT scan set, such as slice thickness and spacing, pixel size, partial volume effects and the reconstructed image orientation. We explored the methods that were minimally influenced by these errors and parameters. The QA phantom (MLC phantom) has been designed for checking a JAW and MLC settings in a 3D-RTPS is used for non-dosimetric QA. We analyzed the CT value of the boundary the structures of the MLC phantom. The relative CT value for thickness 1 mm slice in border of each structure body of MLC phantom respectively shows a decrease of about 2%, 4%, 10% by 2 mm, 3 mm and 5 mm. In case of thickness 5 mm slice, the mean deference of border of virtual radiation beams and phantom was 0.8 mm, and standard deviation of them was 0.6 mm. And the mean difference of border of a DRR image and phantom was 0.08 mm and the standard deviation of them 0.6 mm. In case of thickness 2 mm slice, the mean deference of border of virtual radiation beams and phantom was -0.18 mm, and standard deviation of them was 0.32 mm. And the mean difference of border of a DRR image and phantom was 0.87 mm and the standard deviation of them 0.54 mm. The result of the study is useful for improvement in a precision of non-dosimetric QA. Our method of non-dosimetric QA can minimize human error and influence of several parameters of the CT scan set. The MLC phantom is a useful tool in the QA of radiation therapy with application to 3D-RTPS, CT simulators, and virtual simulation packages with MLC display capabilities. (author)

  1. Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system.

    Directory of Open Access Journals (Sweden)

    Lucas Sacchini Del Lama

    Full Text Available Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated Graft-Versus-Host-Disease (TA-GVHD. However, choosing the appropriate technique to determine the dosimetric parameters associated with blood irradiation remains an issue. We propose a dosimetric system based on the standard Fricke Xylenol Gel (FXG dosimeter and an appropriate phantom. The modified dosimeter was previously calibrated using a (60Co teletherapy unit and its validation was accomplished with a (137Cs blood irradiator. An ionization chamber, standard FXG, radiochromic film and thermoluminescent dosimeters (TLDs were used as reference dosimeters to determine the dose response and dose rate of the (60Co unit. The dose distributions in a blood irradiator were determined with the modified FXG, the radiochromic film, and measurements by TLD dosimeters. A linear response for absorbed doses up to 54 Gy was obtained with our system. Additionally, the dose rate uncertainties carried out with gel dosimetry were lower than 5% and differences lower than 4% were noted when the absorbed dose responses were compared with ionization chamber, film and TLDs.

  2. Prevention of Transfusion-Associated Graft-versus-Host Disease by Irradiation: Technical Aspect of a New Ferrous Sulphate Dosimetric System

    Science.gov (United States)

    Del Lama, Lucas Sacchini; de Góes, Evamberto Garcia; Petchevist, Paulo César Dias; Moretto, Edson Lara; Borges, José Carlos; Covas, Dimas Tadeu; de Almeida, Adelaide

    2013-01-01

    Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated Graft-Versus-Host-Disease (TA-GVHD). However, choosing the appropriate technique to determine the dosimetric parameters associated with blood irradiation remains an issue. We propose a dosimetric system based on the standard Fricke Xylenol Gel (FXG) dosimeter and an appropriate phantom. The modified dosimeter was previously calibrated using a 60Co teletherapy unit and its validation was accomplished with a 137Cs blood irradiator. An ionization chamber, standard FXG, radiochromic film and thermoluminescent dosimeters (TLDs) were used as reference dosimeters to determine the dose response and dose rate of the 60Co unit. The dose distributions in a blood irradiator were determined with the modified FXG, the radiochromic film, and measurements by TLD dosimeters. A linear response for absorbed doses up to 54 Gy was obtained with our system. Additionally, the dose rate uncertainties carried out with gel dosimetry were lower than 5% and differences lower than 4% were noted when the absorbed dose responses were compared with ionization chamber, film and TLDs. PMID:23762345

  3. Update of the Picker C9 irradiator control system of the gamma II room of the secondary laboratory of dosimetric calibration

    International Nuclear Information System (INIS)

    Simon S, L. E.

    2016-01-01

    The Picker C9 irradiator is responsible for the calibration of different radiological equipment and the control system that maintains it in operation is designed in the graphical programming software LabVIEW (Laboratory Virtual Instrumentation Engineering Workbench), being its major advantages: the different types of communication, easy interconnection with other software and the recognition of different hardware devices, among others. Operation of the irradiator control system is performed with the NI-Usb-6008 (DAQ) data acquisition module of the National Instruments Company. The purpose of this work is to update the routines that make the Picker C9 control system of the gamma II room of the secondary laboratory of dosimetric calibration, using the graphic programming software LabVIEW, as well as to configure the new acquisition hardware of data that is implemented to control the Picker C9 irradiator system and ensure its operation. (Author)

  4. Dosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments

    Directory of Open Access Journals (Sweden)

    Bhardwaj Anup

    2007-01-01

    Full Text Available The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT for step and shoot and sliding window (dynamic techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning and speed, stability of dynamic MLC output, inter and intra leaf transmission, dosimetric leaf separation and multiple carriage field verification were performed. Evaluation of standard field patterns as pyramid, peaks, wedge, chair, garden fence test, picket fence test and sweeping gap output was done. Patient dose quality assurance procedure consists of an absolute dose measurement for all fields at 5 cm depth on solid water phantom using 0.6cc water proof ion chamber and relative dose verification using Kodak EDR-2 films for all treatment fields along transverse and coronal direction using IMRT phantom. The relative dose verification was performed using Omni Pro IMRT film verification software. The tests performed showed acceptable results for commissioning the millennium 80 MLC and Clinac DHX for dynamic and step and shoot IMRT treatments.

  5. Dosimetric and delivery efficiency investigation for treating hepatic lesions with a MLC-equipped robotic radiosurgery–radiotherapy combined system

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Lihui, E-mail: lihui.jin@fccc.edu; Price, Robert A.; Wang, Lu; Meyer, Joshua; Fan, James; Charlie Ma, Chang Ming [Department of Radiation Oncology, Fox Chase Cancer Center, 333 Cottman Avenue, Philadelphia, Pennsylvania 19111 (United States)

    2016-02-15

    Purpose: The CyberKnife M6 (CK-M6) Series introduced a multileaf collimator (MLC) for extending its capability from stereotactic radiosurgery/stereotactic radiotherapy (SBRT) to conventionally fractionated radiotherapy. This work is to investigate the dosimetric quality of plans that are generated using MLC-shaped beams on the CK-M6, as well as their delivery time, via comparisons with the intensity modulated radiotherapy plans that were clinically used on a Varian Linac for treating hepatic lesions. Methods: Nine patient cases were selected and divided into three groups with three patients in each group: (1) the group-one patients were treated conventionally (25 fractions); (2) the group-two patients were treated with SBRT-like hypofractionation (5 fractions); and (3) the group-three patients were treated similar to group-one patients, but with two planning target volumes (PTVs) and two different prescription dose levels correspondingly. The clinically used plans were generated on the ECLIPSE treatment planning system (TPS) and delivered on a Varian Linac (E-V plans). The multiplan (MP) TPS was used to replan these clinical cases with the MLC as the beam device for the CK-M6 (C-M plans). After plans were normalized to the same PTV dose coverage, comparisons between the C-M and E-V plans were performed based on D{sub 99%} (percentage of prescription dose received by 99% of the PTV), D{sub 0.1cm{sup 3}} (the percentage of prescription dose to 0.1 cm{sup 3} of the PTV), and doses received by critical structures. Then, the delivery times for the C-M plans will be obtained, which are the MP TPS generated estimations assuming having an imaging interval of 60 s. Results: The difference in D{sub 99%} between C-M and E-V plans is +0.6% on average (+ or − indicating a higher or lower dose from C-M plans than from E-V plans) with a range from −4.1% to +3.8%, and the difference in D{sub 0.1cm{sup 3}} was −1.0% on average with a range from −5.1% to +2.9%. The PTV

  6. Dosimetric and delivery efficiency investigation for treating hepatic lesions with a MLC-equipped robotic radiosurgery–radiotherapy combined system

    International Nuclear Information System (INIS)

    Jin, Lihui; Price, Robert A.; Wang, Lu; Meyer, Joshua; Fan, James; Charlie Ma, Chang Ming

    2016-01-01

    Purpose: The CyberKnife M6 (CK-M6) Series introduced a multileaf collimator (MLC) for extending its capability from stereotactic radiosurgery/stereotactic radiotherapy (SBRT) to conventionally fractionated radiotherapy. This work is to investigate the dosimetric quality of plans that are generated using MLC-shaped beams on the CK-M6, as well as their delivery time, via comparisons with the intensity modulated radiotherapy plans that were clinically used on a Varian Linac for treating hepatic lesions. Methods: Nine patient cases were selected and divided into three groups with three patients in each group: (1) the group-one patients were treated conventionally (25 fractions); (2) the group-two patients were treated with SBRT-like hypofractionation (5 fractions); and (3) the group-three patients were treated similar to group-one patients, but with two planning target volumes (PTVs) and two different prescription dose levels correspondingly. The clinically used plans were generated on the ECLIPSE treatment planning system (TPS) and delivered on a Varian Linac (E-V plans). The multiplan (MP) TPS was used to replan these clinical cases with the MLC as the beam device for the CK-M6 (C-M plans). After plans were normalized to the same PTV dose coverage, comparisons between the C-M and E-V plans were performed based on D_9_9_% (percentage of prescription dose received by 99% of the PTV), D_0_._1_c_m_"3 (the percentage of prescription dose to 0.1 cm"3 of the PTV), and doses received by critical structures. Then, the delivery times for the C-M plans will be obtained, which are the MP TPS generated estimations assuming having an imaging interval of 60 s. Results: The difference in D_9_9_% between C-M and E-V plans is +0.6% on average (+ or − indicating a higher or lower dose from C-M plans than from E-V plans) with a range from −4.1% to +3.8%, and the difference in D_0_._1_c_m_"3 was −1.0% on average with a range from −5.1% to +2.9%. The PTV conformity index (CI) for

  7. 76 FR 22157 - Postal Service Rate Adjustment

    Science.gov (United States)

    2011-04-20

    ... identifies Greg Dawson, Manager of Pricing Strategy, as the official responsible for responding to any... program is an example of the increased pricing flexibility under the Postal Accountability and Enhancement...

  8. 76 FR 395 - New Postal Product

    Science.gov (United States)

    2011-01-04

    ... INFORMATION: Table of Contents I. Introduction II. Notice of Filing III. Ordering Paragraphs I. Introduction... Sample Showcase box, including marketing, assembling, and tendering the box for delivery by the Postal...

  9. 76 FR 54510 - New Postal Product

    Science.gov (United States)

    2011-09-01

    ... Service request to enter into an additional agreement under the ``International Business Reply Service... into an additional International Business Reply Service (IBRS) Competitive contract.\\1\\ The Postal... International Business Reply Service Competitive Contract 3 Negotiated Service Agreement, August 19, 2011...

  10. 75 FR 7634 - New Postal Product

    Science.gov (United States)

    2010-02-22

    ... public that the Postal Service has filed a request to add International Business Reply Service... entered into two additional International Business Reply Service (IBRS) Contracts.\\1\\ Additionally, the... to Establish Successor Instruments as Baseline International Business Reply Service Competitive...

  11. 39 CFR 221.7 - Postal Service emblem.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Postal Service emblem. 221.7 Section 221.7 Postal... Service emblem. The Postal Service emblem, which is identical with the seal, is registered as a trademark and service mark by the U.S. Patent Office. Except for the emblem on official stationery, the emblem...

  12. Development of a dosimetric system for emergency situation involving person of the public; Desenvolvimento de um sistema dosimetrico para situacoes de emergencia envolvendo pessoas do publico em geral

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Zelia Maria da

    1999-07-01

    A dosimetric system was developed for emergency situation based on electron spin resonance spectrometry (E.S.R.) and some materials such as tooth enamel, bovine bone, CaCO{sub 3} and sugar as detector. The purpose of this work was to find common materials, which are both reliable and sensitive and make possible quickly to assess the absorbed dose. The research includes the collection and preparation of samples, the evaluation, treatment and interpretation of ESR signal and the procedure for dose reconstruction. The calibration of the dosemeter was performed using gamma radiation from a Co-60 source. The results obtained confirm the variability of the use of this system in case of an accident. (author)

  13. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba; Servicio Postal TLD para auditorias de calidad de haces de Co-60 en condiciones de referencia en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, C. Habana (Cuba)]. e-mail: stefan@cphr.edu.cu

    2006-07-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  14. SU-F-J-121: Dosimetric Evaluation of Active Breathing Coordinator-Response Gating System Linked to Linear Accelerator in Volumetric Modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Zheng, Y; Albani, D; Colussi, V; Dorth, J; Sohn, J [Case Western University, Cleveland, OH (United States)

    2016-06-15

    Purpose: To reduce internal target volume (ITV), respiratory management is a must in imaging and treatment for lung, liver, and breast cancers. We investigated the dosimetric accuracy of VMAT treatment delivery with a Response™ gating system linked to linear accelerator. Methods: The Response™ gating module designed to directly control radiation beam by breath-holding with a ABC system (Elekta AB, Stockholm, Sweden) was tested for VMAT treatments. Seven VMAT plans including three conventional and four stereotactic body radiotherapy (SBRT) cases were evaluated. Each plan was composed of two or four arcs of 6MV radiation beam with prescribed dose ranged from 1.8 to 9 Gy per fraction. Each plan was delivered continuously without gating and delivered with multiple interruptions by the ResponseTM gating module with a 20 or 30 second breath-holding period. MapCheck2 and Gafchromic EBT3 films sandwiched in MapPHAN were used to measure the delivered dose with and without gating. Films were scanned on a flatbed color scanner, and red channel was extracted for film dosimetry. Gamma analysis was performed to analyze the dosimetrical accuracy of the radiation delivery with gating. Results: The measured doses with gating remarkably agree with the planned dose distributions in the results of gamma index passing rate (within 20% isodose; >98% for 3%/3mm and >92% for 2%/2mm in MapCheck2, and >91% for 3%/3mm criteria in EBT3 film except one case which was for large target and highly modulated). No significant difference (student t-test: p-value < 0.0005) was shown between the doses delivered with and without gating. There was no indication of radiation gap or overlapping during deliver interruption in film dosimetry. Conclusion: The Response™ gating system can be safely used during VMAT treatment. The accurate performance of the gating system linked to ABC can contribute to ITV reduction for SBRT using VMAT.

  15. Quality Control in the Dosimetric System of the Personnel Dosimetry Service of the Spanish National Health Service

    Energy Technology Data Exchange (ETDEWEB)

    Casal, E.; Gil, J.A.; Roig, F.; Soriano, A. [Valencia (Spain)

    1999-07-01

    The main operating and quality control procedures implemented at the Centro Nacional de Dosimetria (CND) of the Spanish National Health Service to ensure the acceptance of the dosimetry service are described. The operating procedures are routinely performed at every step, since the dosemeters are received from the manufacturer until the doses are assigned to the dosimetric history and their main aim is to ensure the traceability of the doses. They make use of control and background dosemeters and frequent cross reference (automatic and manual) of different sources of data. The control procedures are performed at the end of each monthly process to detect possible errors or systematic bias in the dosimetry service and include analysis of the measurements of quality control dosemeters irradiated at the CND's laboratory and randomly read. The results of this analysis since 1996 are presented. (author)

  16. Quality Control in the Dosimetric System of the Personnel Dosimetry Service of the Spanish National Health Service

    International Nuclear Information System (INIS)

    Casal, E.; Gil, J.A.; Roig, F.; Soriano, A.

    1999-01-01

    The main operating and quality control procedures implemented at the Centro Nacional de Dosimetria (CND) of the Spanish National Health Service to ensure the acceptance of the dosimetry service are described. The operating procedures are routinely performed at every step, since the dosemeters are received from the manufacturer until the doses are assigned to the dosimetric history and their main aim is to ensure the traceability of the doses. They make use of control and background dosemeters and frequent cross reference (automatic and manual) of different sources of data. The control procedures are performed at the end of each monthly process to detect possible errors or systematic bias in the dosimetry service and include analysis of the measurements of quality control dosemeters irradiated at the CND's laboratory and randomly read. The results of this analysis since 1996 are presented. (author)

  17. Dosimetric quality control of treatment planning systems in external radiation therapy using Digital Test Objects calculated by PENELOPE Monte-Carlo simulations

    International Nuclear Information System (INIS)

    Ben Hdech, Yassine

    2011-01-01

    To ensure the required accuracy and prevent from mis-administration, cancer treatments, by external radiation therapy are simulated on Treatment Planning System or TPS before radiation delivery in order to ensure that the prescription is achieved both in terms of target volumes coverage and healthy tissues protection. The TPS calculates the patient dose distribution and the treatment time per beam required to deliver the prescribed dose. TPS is a key system in the decision process of treatment by radiation therapy. It is therefore essential that the TPS be subject to a thorough check of its performance (quality control or QC) and in particular its ability to accurately compute dose distributions for patients in all clinical situations that be met. The 'traditional' methods recommended to carry out dosimetric CQ of algorithms implemented in the TPS are based on comparisons between dose distributions calculated with the TPS and dose measured in physical test objects (PTO) using the treatment machine. In this thesis we propose to substitute the reference dosimetric measurements performed in OTP by benchmark dose calculations in Digital Test Objects using PENELOPE Monte-Carlo code. This method has three advantages: (i) it allows simulation in situations close to the clinic and often too complex to be experimentally feasible; (ii) due to the digital form of reference data the QC process may be automated; (iii) it allows a comprehensive TPS CQ without hindering the use of an equipment devoted primarily to patients treatments. This new method of CQ has been tested successfully on the Eclipse TPS from Varian Medical Systems Company. (author) [fr

  18. Morocco : French postal administration after 1912 and Morocco's postal services during the First World War

    NARCIS (Netherlands)

    Dietz, A.J.

    2017-01-01

    An earlier version of (parts of) APH 5 was published as African Studies Centre Leiden Working Paper 125 / 2016: "A postal history of the First World War in Africa and its aftermath - German colonies/postal areas : V Morocco", written by Ton Dietz.

  19. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  20. SU-F-T-501: Dosimetric Comparison of Single Arc-Per-Beam and Two Arc-Per-Beam VMAT Optimization in the Monaco Treatment Planning System

    Energy Technology Data Exchange (ETDEWEB)

    Kalet, A; Cao, N; Meyer, J; Dempsey, C [University of Washington Medical Center, Seattle, WA (United States); Seattle Cancer Care Alliance, Seattle, WA (United States); Richardson, H [Seattle Cancer Care Alliance, Seattle, WA (United States)

    2016-06-15

    Purpose: The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. Methods: A total of 17 previously treated patients were selected for this study with a range of pelvic disease site including prostate(9), bladder(1), uterus(3), rectum(3), and cervix(1). For each patient, two plans were generated, one using a arc-per-beam setting of ‘1’ and another with setting of ‘2’. The setting allows the optimizer to add a gantry direction change, creating multiple arc passes per beam sequence. Volumes and constraints established from the initial clinical treatments were used for planning. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the PTV received 95% of the prescription dose. We evaluated the PTV conformity index, homogeneity index, total monitor units, number of control points, and various dose volume histogram (DVH) points for statistical comparison (alpha=0.05). Results: We found for the 10 complex shaped target volumes (small central volumes with extending bilateral ‘arms’ to cover nodal regions) that the use of 2 arcs-per-beam achieved significantly lower average DVH values for the bladder V20 (p=0.036) and rectum V30 (p=0.001) while still meeting the high dose target constraints. DVH values for the simpler, more spherical PTVs were not found significantly different. Additionally, we found a beam delivery time reduction of approximately 25%. Conclusion: In summary, the dosimetric benefit, while moderate, was improved over a 1 arc-per-beam setting for complex PTVs, and equivalent in other cases. The overall reduced delivery time suggests that the use of multiple arcs-per-beam could lead to reduced patient on table time, increased clinical throughput, and reduced medical physics quality assurance effort.

  1. COORDINATES OF POSTAL SERVICES MARKET IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Cristinel CONSTANTIN

    2012-01-01

    Full Text Available This paper contains a research regarding the actual status of Romanian postal services market both from legislative and economic point of view in the context of EU integration. The main objectives of this research were to identify the position of Romanian postal services among the EU member countries and to analyse the competitive environment on the local market in order to find future development strategies for the local companies. The outcomes of our research show a wrong position of Romanian postal sector both regarding the number of permanent offices and financial results of local competitors. The lateness of structural reforms could be a barrier for the future market liberalisation with serious consequences from the social point of view. In this context, a high implication of authorities is expected in order to ensure the adoption of EU regulation with a minimum of negative effects both for population and service providers.

  2. BeOSL system for personal dosimetry : dosimetric characteristics and practical application; Sistema BeOSL para dosimetria personal : caracteristicas dosimetricas y la aplicacion practica

    Energy Technology Data Exchange (ETDEWEB)

    Mende, E. [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, Working Group Engineering, D-85764 Neuherberg (Germany)

    2015-10-15

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  3. High-resolution digital dosimetric system for spatial characterization of radiation fields using a thermoluminescent CaF2:Dy crystal

    International Nuclear Information System (INIS)

    Atari, N.A.; Svensson, G.K.

    1986-01-01

    A high-resolution digital dosimetric system has been developed for the spatial characterization of radiation fields. The system comprises the following: 0.5-mm-thick, 25-mm-diam CaF2:Dy thermoluminescent crystal; intensified charge coupled device video camera; video cassette recorder; and a computerized image processing subsystem. The optically flat single crystal is used as a radiation imaging device and the subsequent thermally stimulated phosphorescence is viewed by the intensified camera for further processing and analysis. Parameters governing the performance characteristics of the system were measured. A spatial resolution limit of 31 +/- 2 microns (1 sigma) corresponding to 16 +/- 1 line pairs/mm measured at the 4% level of the modulation transfer function has been achieved. The full width at half maximum of the line spread function measured independently by the slit method or derived from the edge response function was found to be 69 +/- 4 microns (1 sigma). The high resolving power, speed of readout, good precision, wide dynamic range, and the large image storage capacity make the system suitable for the digital mapping of the relative distribution of absorbed doses for various small radiation fields and the edges of larger fields

  4. High-resolution digital dosimetric system for spatial characterization of radiation fields using a thermoluminescent CaF2:Dy crystal

    International Nuclear Information System (INIS)

    Atari, N.A.; Svensson, G.K.

    1986-01-01

    A high-resolution digital dosimetric system has been developed for the spatial characterization of radiation fields. The system comprises the following: 0.5-mm-thick, 25-mm-diam CaF 2 :Dy thermoluminescent crystal; intensified charge coupled device video camera; video cassette recorder; and a computerized image processing subsystem. The optically flat single crystal is used as a radiation imaging device and the subsequent thermally stimulated phosphorescence is viewed by the intensified camera for further processing and analysis. Parameters governing the performance characteristics of the system were measured. A spatial resolution limit of 31 +- 2 μm (1sigma) corresponding to 16 +- 1 line pair/mm measured at the 4% level of the modulation transfer function has been achieved. The full width at half maximum of the line spread function measured independently by the slit method or derived from the edge response function was found to be 69 +- 4 μm (1sigma). The high resolving power, speed of readout, good precision, wide dynamic range, and the large image storage capacity make the system suitable for the digital mapping of the relative distribution of absorbed doses for various small radiation fields and the edges of larger fields

  5. 75 FR 12445 - New Postal Product

    Science.gov (United States)

    2010-03-16

    ... Commission is adding International Business Reply Service Competitive Contract 2 to the Competitive Product List. This action is consistent with a postal reform law. Republication of the Market Dominant and... identified as International Business Reply Service Competitive Contract 2 to the Competitive Product [[Page...

  6. 75 FR 65676 - New Postal Product

    Science.gov (United States)

    2010-10-26

    ... contract for future functional equivalence analyses of the GEPS 3 product. \\1\\ Notice of United States... Schedule language for the GEPS 3 product. The Postal Service identifies customer-specific information and... Service asserts that ``[b]ecause the agreements incorporate the same cost attributes and methodology, the...

  7. 76 FR 49798 - New Postal Product

    Science.gov (United States)

    2011-08-11

    ... Docket No. CP2010-36 serve as the baseline contract for future functional equivalence analyses of the... Classification Schedule language for GREP Contracts 1. The Postal Service states that the instant contract... agreement incorporates the same cost attributes and methodology, the relevant characteristics of this GREP...

  8. 75 FR 72845 - New Postal Product

    Science.gov (United States)

    2010-11-26

    ... contract for future functional equivalence analyses of the GEPS 3 product. \\1\\ Notice of United States... Classification Schedule language for the GEPS 3 product. The Postal Service identifies customer-specific... methodology, the relevant characteristics of these five GEPS contracts are similar, if not the same, as the...

  9. 75 FR 61785 - New Postal Product

    Science.gov (United States)

    2010-10-06

    ... have the contract in Docket No. CP2010-71 serve as the baseline contract for future functional... GEPS 3 contracts fit within the Mail Classification Schedule language for GEPS. The Postal Service... same cost attributes and methodology, the relevant characteristics of these seven GEPS contracts are...

  10. 75 FR 57995 - New Postal Product

    Science.gov (United States)

    2010-09-23

    ... contract for future functional equivalence analyses of the GEPS 3 product. \\1\\ Notice of United States... Schedule language for the GEPS product. The Postal Service identifies customer-specific information and... Service asserts that ``[b]ecause the agreements incorporate the same cost attributes and methodology, the...

  11. 75 FR 67147 - New Postal Product

    Science.gov (United States)

    2010-11-01

    ... requested to have the contract in Docket No. CP2010-36 serve as the baseline contract for future functional... GREP contract fits within the Mail Classification Schedule language for GREP Contracts 1. The Postal... incorporates the same cost attributes and methodology, the relevant characteristics of this GREP contract are...

  12. 75 FR 54401 - New Postal Product

    Science.gov (United States)

    2010-09-07

    ... Docket No. CP2010-71 serve as the baseline contract for future functional equivalence analyses of the... Classification Schedule language for GEPS. The Postal Service identifies customer-specific information and... Service asserts that ``[b]ecause the agreements incorporate the same cost attributes and methodology, the...

  13. 75 FR 57303 - New Postal Product

    Science.gov (United States)

    2010-09-20

    ... Docket No. CP2010-71 serve as the baseline contract for future functional equivalence analyses of the... fit within the Mail Classification Schedule language for GEPS. The Postal Service identifies customer... attributes and methodology, the relevant characteristics of these 11 GEPS contracts are similar, if not the...

  14. 78 FR 37246 - New Postal Product

    Science.gov (United States)

    2013-06-20

    ... statement, and supporting financial workpapers. Id. The Postal Service filed redacted versions of the... extension was based on the understanding a successor agreement would be filed. See Docket No. CP2012-30...--a redacted copy of the certified statement required by 39 CFR 3015.5(c)(2); Attachment 3--a redacted...

  15. 75 FR 7951 - New Postal Product

    Science.gov (United States)

    2010-02-23

    ... is adding Express Mail Contract 8 to the Competitive Product List. This action is consistent with a postal reform law. Republication of the Product Lists is also consistent with a statutory provision... seeks to add a new product identified as Express Mail Contract 8 to the Competitive Product List. For...

  16. 78 FR 33451 - New Postal Product

    Science.gov (United States)

    2013-06-04

    .... Introduction II. Contents of Filing III. Commission Action IV. Ordering Paragraphs I. Introduction On May 24... and supporting financial information required by 39 CFR 3015.5(c).\\2\\ For purposes of 39 CFR 3015.5(a...' Decision No. 11-6 authorizes Postal Service management to prepare and present to the Commission product...

  17. 75 FR 78915 - Conduct on Postal Property

    Science.gov (United States)

    2010-12-17

    ... lottery ticket sales contains an exception for Randolph-Sheppard vendors. This exception is amended to... tickets ``for any lottery authorized by State law and conducted by an agency of a State''. This amendment... lottery or pool, or the selling or purchasing of lottery tickets, is prohibited on postal premises. In...

  18. 75 FR 42171 - New Postal Product

    Science.gov (United States)

    2010-07-20

    ... establishes Docket No. CP2010-66 for consideration of matters related to the contract identified in the Postal... Service request to add a Global Expedited Package Services 2 (GEPS 2) contract to the existing GEPS 2... announcing that it has entered into an additional Global Expedited Package Services 2 (GEPS 2) contract.\\1...

  19. 75 FR 80859 - New Postal Product

    Science.gov (United States)

    2010-12-23

    ... consideration of the Request pertaining to the proposed Priority Mail Contract 32 product and the related... recently-filed Postal Service request to add Priority Mail Contract 32 to the competitive product list... Service filed a formal request and associated supporting information to add Priority Mail Contract 32 to...

  20. 75 FR 80857 - New Postal Product

    Science.gov (United States)

    2010-12-23

    ... CP2011-46 for consideration of the Request pertaining to the proposed Priority Mail Contract 31 product... recently-filed Postal Service request to add Priority Mail Contract 31 to the competitive product list... Service filed a formal request and associated supporting information to add Priority Mail Contract 31 to...

  1. 77 FR 54937 - International Mail Postal Contract

    Science.gov (United States)

    2012-09-06

    ... recently-filed Postal Service filing addressing a new International Business Reply Service Contract 3. It... contract within the International Business Reply Service (IBRS) Competitive Contract 3 grouping.\\1\\ The... Service Filing of a Functionally Equivalent International Business Reply Service Competitive Contract 3...

  2. 75 FR 5236 - New Postal Product

    Science.gov (United States)

    2010-02-02

    ... Description] Premium Stamped Stationery [Reserved for Product Description] Premium Stamped Cards [Reserved for... determine whether such an agreement (1) Improves the net financial position of the Postal Service or... Descriptions First-Class Mail [Reserved for Class Description] Single-Piece Letters/Postcards [Reserved for...

  3. 76 FR 10410 - New Postal Product

    Science.gov (United States)

    2011-02-24

    ... recently-filed Postal Service request to add International Business Reply Service (IBRS) Competitive... International Business Reply Service (IBRS) Competitive Contract 3 to the competitive product list and... International Business Reply Service Competitive Contract 3 to the Competitive Products List and Notice of...

  4. 75 FR 44138 - New Postal Products

    Science.gov (United States)

    2010-07-28

    ... Service International Business Reply Mail Service Money Orders Post Office Box Service Negotiated Service... International Reply Coupon Service International Business Reply Mail Service Money Orders Post Office Box... Entry Contracts with Foreign Postal Administrations 1 (MC2008-6 and CP2009-62) International Business...

  5. 76 FR 11532 - New Postal Product

    Science.gov (United States)

    2011-03-02

    ... filing concerning an additional International Business Reply Service (IBRS) Competitive Contract 3. It..., that it has entered into an additional International Business Reply Service (IBRS) Competitive contract...-59, Request of the United States Postal Service to Add International Business Reply Service...

  6. 75 FR 52786 - New Postal Product

    Science.gov (United States)

    2010-08-27

    ...: 1. Attachment 1--proposed Mail Classification Schedule (MCS) language for Inbound Market Dominant... fit within the proposed MCS language, are with foreign postal operators, conform to a common..., 2010. The public portions of these filings can be accessed via the Commission's website ( http://www...

  7. 75 FR 45175 - New Postal Product

    Science.gov (United States)

    2010-08-02

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... to the competitive product list. This notice addresses procedural steps associated with the filing... that Order No. 86, which established GEPS 1 as a product, also authorized functionally equivalent...

  8. 77 FR 24996 - New Postal Product

    Science.gov (United States)

    2012-04-26

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... product list. This notice addresses procedural steps associated with the filing. DATES: Comments are due... supporting information to add First-Class Package Service Contract 1 to the Competitive Product List.\\1\\ The...

  9. 77 FR 61307 - New Postal Product

    Science.gov (United States)

    2012-10-09

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a... dominant product list to the competitive product list as ``Lightweight Parcel Select,'' a subcategory of... Granting Request to Transfer Commercial Standard Mail Parcels to the Competitive Product List, March 2...

  10. 78 FR 65015 - New Postal Product

    Science.gov (United States)

    2013-10-30

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing recent... product list. This notice informs the public of the filings, invites public comment, and takes other... Service Contract 5 to the competitive product list.\\1\\ It is the successor agreement to the contract...

  11. 78 FR 79025 - New Postal Product

    Science.gov (United States)

    2013-12-27

    ... Product AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is noticing a recent... product list. This notice informs the public of the filing, invites public comment, and takes other... associated supporting information to add Priority Mail Express Contract 17 to the competitive product list.\\1...

  12. 76 FR 13242 - Change in Postal Prices

    Science.gov (United States)

    2011-03-10

    [email protected] (electronic filing assistance). SUPPLEMENTARY INFORMATION: Table of Contents I. Introduction II. Notice of Filings III. Ordering Paragraphs I. Introduction On March 1, 2011, the Commission... Postal Service-branded parcel box designed to contain product samples and other advertising material from...

  13. 78 FR 77508 - New Postal Product

    Science.gov (United States)

    2013-12-23

    ... Counsel, at 202-789-6820. SUPPLEMENTARY INFORMATION: Table of Contents I. Introduction II. Contents of Filing III. Commission Action IV. Ordering Paragraphs I. Introduction Notice of filing. On December 16...' Decision, the new rates and related financial information. Id. at 3. The Postal Service filed redacted...

  14. 76 FR 29013 - Change in Postal Prices

    Science.gov (United States)

    2011-05-19

    ... Contents I. Introduction II. Notice of Filing III. Ordering Paragraphs I. Introduction On May 11, 2011, the... Service Contract 2 accompanies the Notice. Additionally, the Postal Service states that the financial... methodology is still pending, the notice also provides a financial analysis based upon the current methodology...

  15. 76 FR 80985 - New Postal Product

    Science.gov (United States)

    2011-12-27

    ... calendar year 2011. Id. at 3. Both notices expressed the Postal Service's view that the contingency pricing....gov/prc-pages/filing-online/login.aspx . Commenters who cannot submit their views electronically..., pursuant to 39 CFR 3015.5, of contingency prices under an outstanding International Business Reply Service...

  16. 75 FR 23824 - New Postal Products

    Science.gov (United States)

    2010-05-04

    ... of Classification Change to Add Existing Shipping Charges to the Mail Classification Schedule for... Form 3202-X, October 2009). Id., Attachment A. The Postal Service states further its belief that the... MCS.\\2\\ Attachment B to the Notice shows the proposed changes to the Stamped Envelope MCS language in...

  17. Geometric and dosimetric verification of step-and-shoot modulated fields with a new fast and high resolution beam imaging system

    International Nuclear Information System (INIS)

    Bindoni, Luca

    2005-01-01

    A technique for geometric and dosimetric pretreatment verification of step-and-shoot intensity modulated radiotherapy treatments (IMRT) using a beam imaging system (BIS) made up of a charge-coupled device (CCD) digital camera optically coupled with a metal-plate/phosphor screen is described. Some physical properties of BIS were investigated in order to demonstrate its capability to perform measurements with a high spatial resolution and a high sampling rate. High-speed imaging, with a minimum charge integration time on the CCD of 120 ms, can be performed. The study of the signal-to-noise ratio as a function of sampling time is presented. In-plane and cross-line pixel size was measured to be 0.368±0.004 mm/pixel, which agrees within 0.5% of the manufacturer value of 0.366 mm. Spatial linearity results are very good and there are no detectable image distortions on whole 30x30 cm 2 detector area. A software routine was written to automatically extract positions of the collimator leaves from the images of the field shaped by the multileaf collimator (MLC) and also to compare them with the coordinates from the treatment planning system (TPS), thus directly testing both the MLC positioning and the treatment parameters transfer from TPS to the linear accelerator in a fast and precise way. The dosimetric capabilities (characteristics) of the imaging device for photon beams with energies of 6 and 15 MV were studied. Additional plexiglass buildup layers, depending on x-ray energy, were needed to reach maximum efficiency. The energy dependence of the BIS response versus dose and dose rate was found to be linear over a wide range. Relative output factors of BIS as a function of field size, compared with values measured with an ionization chamber, were in good accord for smaller field sizes ≤10x10 cm 2 but showed differences up to 4% for all the energies at the respective buildup depth for bigger fields. Square field profiles at water-equivalent buildup depths, extracted

  18. 78 FR 12801 - New Postal Product; Negotiated Service Agreement

    Science.gov (United States)

    2013-02-25

    ... the United States Postal Service to Add Parcel Return Service Contract 3 to Competitive Product List... Commission is noticing a recently-filed Postal Service request to add Parcel Return Service Contract 3 to the....30 et seq., the Postal Service filed a request and associated supporting information to add Parcel...

  19. 76 FR 77271 - Competitive Product Postal Price Changes

    Science.gov (United States)

    2011-12-12

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2012-2; Order No. 997] Competitive Product Postal Price... recently-filed Postal Service request for a change in competitive products prices. The changes will take... and justification for the changes, the effective date, and a schedule of the changed rates. The price...

  20. The Essence of the Concept of «Wages Fund», and Impact of Legislative Changes of the Term of «Minimum Wage» on the Wage System of the Enterprise of Postal Service «Ukrposhta»

    Directory of Open Access Journals (Sweden)

    Buriak Valerii G.

    2017-04-01

    Full Text Available The article is aimed at substantiating the necessity of optimizing the pay scheme under the influence of legislative changes of the concept of «minimum wage». Studying the influence of legislative changes in the definition of the essence of concept of «minimum wage» and the wage system, used at the enterprise of postal service «Ukrposhta», has led to the conclusion that beginning from January 1, 2017 it is of the socially unjust and unfounded nature, because the principle of motivation of employees in respect of wages matching the quantity, quality, and results of labor, has been defied. It has been proposed to restructure the wage system at the enterprise of postal service «Ukrposhta» by optimizing the cross-categorial and cross-qualification relations, as well as the payment scheme.

  1. 39 CFR 1.1 - Establishment of the U.S. Postal Service.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Establishment of the U.S. Postal Service. 1.1 Section 1.1 Postal Service UNITED STATES POSTAL SERVICE THE BOARD OF GOVERNORS OF THE U.S. POSTAL SERVICE POSTAL POLICY (ARTICLE I) § 1.1 Establishment of the U.S. Postal Service. The U.S. Postal Service is...

  2. Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system

    Energy Technology Data Exchange (ETDEWEB)

    Kalet, Alan M., E-mail: amkalet@uw.edu [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Seattle Cancer Care Alliance, Seattle, Washington (United States); Richardson, Hannah L.; Nikolaisen, Darrin A. [Seattle Cancer Care Alliance, Seattle, Washington (United States); Cao, Ning [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Seattle Cancer Care Alliance, Seattle, Washington (United States); Lavilla, Myra A. [Seattle Cancer Care Alliance, Seattle, Washington (United States); Dempsey, Claire; Meyer, Juergen; Koh, Wui-Jin; Russell, Kenneth J. [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Seattle Cancer Care Alliance, Seattle, Washington (United States)

    2017-07-01

    The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. We selected for this study a total of 17 previously treated patients with a range of pelvic disease sites including prostate (9), bladder (1), uterus (3), rectum (3), and cervix (1). For each patient, 2 plans were generated, one using an arc-per-beam setting of “1” and another with an arc-per-beam setting of “2” using the volumes and constraints established from the initial clinical treatments. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the planning target volume (PTV) received 95% of the prescription dose. Plans were evaluated for PTV conformity, homogeneity, number of monitor units, number of control points, and overall plan acceptability. Treatment delivery time, patient-specific quality assurance procedures, and the impact on clinical workflow were also assessed. We found that for complex-shaped target volumes (small central volumes with extending arms to cover nodal regions), the use of 2 arc-per-beam (2APB) parameter setting achieved significantly lower average dose-volume histogram values for the rectum V{sub 20} (p = 0.0012) and bladder V{sub 30} (p = 0.0036) while meeting the high dose target constraints. For simple PTV shapes, we found reduced monitor units (13.47%, p = 0.0009) and control points (8.77%, p = 0.0004) using 2APB planning. In addition, we found a beam delivery time reduction of approximately 25%. In summary, the dosimetric benefit, although moderate, was improved over a 1APB setting for complex PTV, and equivalent in other cases. The overall reduced delivery time suggests that the use of mulitple arcs per beam could lead to reduced patient-on-table time, increased clinical throughput, and reduced medical physics quality assurance

  3. 39 CFR 762.43 - Issuance of substitute disbursement postal money order.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Issuance of substitute disbursement postal money...; DISBURSEMENT POSTAL MONEY ORDERS DISBURSEMENT POSTAL MONEY ORDERS Issuance of Substitutes for Lost, Destroyed, Mutilated, and Defaced Disbursement Postal Money Orders § 762.43 Issuance of substitute disbursement postal...

  4. Rectal toxicity profile after transperineal interstitial permanent prostate brachytherapy: Use of a comprehensive toxicity scoring system and identification of rectal dosimetric toxicity predictors

    International Nuclear Information System (INIS)

    Shah, Jinesh N.; Ennis, Ronald D.

    2006-01-01

    Purpose: To better understand rectal toxicity after prostate brachytherapy, we employed the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0), a comprehensive system with distinct and separately reported gastrointestinal adverse event items (unlike Radiation Therapy Oncology Group morbidity scoring), to evaluate item-specific postimplant rectal toxicities. Methods and Materials: We analyzed 135 patients treated with brachytherapy ± hormonal therapy, using CTCAE v3.0 to score acute/late rectal toxicities (median follow-up, 41 months). Dosimetric parameters were evaluated for ability to predict toxicities. Results: Use of CTCAE yielded a novel rectal toxicity profile consisting of diarrhea, incontinence, urgency, proctitis, pain, spasms, and hemorrhage event rates. No item had a 25 (percent of rectal volume receiving 25% of prescribed prostate dose) ≤ 25% vs. 60% for %V 25 > 25% (p 1 ≤ 40% vs. 44% for %V 1 > 40% (p = 0.007). Conclusions: A comprehensive understanding of item-specific postimplant rectal toxicities was obtained using CTCAE. Rectal %V 25 > 25% and %V 1 > 40% predicted worse late diarrhea and maximum toxicity, respectively

  5. Development and application of a dosimetric methodology of therapeutic X radiation beams using a tandem system; Desenvolvimento e aplicacao de metodologia dosimetrica de feixes terapeuticos de raios X com sistema tandem

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, Carla Eri

    2001-07-01

    In radiotherapy the use of orthovoltage X radiation beams is still recommended; to obtain satisfactory results, a periodic control is necessary to check the performance of the ionization chambers and the radiation beams characteristics. This control is performed by using standard dosimetric procedures, as for example the determination of half-value layers and the absorbed dose rates. A Tandem system was established in this work using a pair of ionization chambers (a thimble type and a superficial type) used for measures in a medical institution, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The results obtained show the application of this method in dosimetric procedures of orthovoltage beams (radiotherapy) as a complement for a quality control program. (author)

  6. SU-E-T-256: Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Y [Tokai University School of Medicine, Isehara, Kanagawa (Japan)

    2015-06-15

    Purpose: Intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are techniques that are widely used for treating cancer due to better target coverage and critical structure sparing. The increasing complexity of IMRT and VMAT plans leads to decreases in dose calculation accuracy. Monte Carlo simulations are the most accurate method for the determination of dose distributions in patients. However, the simulation settings for modeling an accurate treatment head are very complex and time consuming. The purpose of this work is to report our implementation of a simple Monte Carlo simulation system in a cloud-computing environment for dosimetric verification of IMRT and VMAT plans. Methods: Monte Carlo simulations of a Varian Clinac linear accelerator were performed using the BEAMnrc code, and dose distributions were calculated using the DOSXYZnrc code. Input files for the simulations were automatically generated from DICOM RT files by the developed web application. We therefore must only upload the DICOM RT files through the web interface, and the simulations are run in the cloud. The calculated dose distributions were exported to RT Dose files that can be downloaded through the web interface. The accuracy of the calculated dose distribution was verified by dose measurements. Results: IMRT and VMAT simulations were performed and good agreement results were observed for measured and MC dose comparison. Gamma analysis with a 3% dose and 3 mm DTA criteria shows a mean gamma index value of 95% for the studied cases. Conclusion: A Monte Carlo-based dose calculation system has been successfully implemented in a cloud environment. The developed system can be used for independent dose verification of IMRT and VMAT plans in routine clinical practice. The system will also be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems. This work was supported by JSPS KAKENHI Grant Number 25861057.

  7. SU-E-T-256: Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification

    International Nuclear Information System (INIS)

    Fujita, Y

    2015-01-01

    Purpose: Intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are techniques that are widely used for treating cancer due to better target coverage and critical structure sparing. The increasing complexity of IMRT and VMAT plans leads to decreases in dose calculation accuracy. Monte Carlo simulations are the most accurate method for the determination of dose distributions in patients. However, the simulation settings for modeling an accurate treatment head are very complex and time consuming. The purpose of this work is to report our implementation of a simple Monte Carlo simulation system in a cloud-computing environment for dosimetric verification of IMRT and VMAT plans. Methods: Monte Carlo simulations of a Varian Clinac linear accelerator were performed using the BEAMnrc code, and dose distributions were calculated using the DOSXYZnrc code. Input files for the simulations were automatically generated from DICOM RT files by the developed web application. We therefore must only upload the DICOM RT files through the web interface, and the simulations are run in the cloud. The calculated dose distributions were exported to RT Dose files that can be downloaded through the web interface. The accuracy of the calculated dose distribution was verified by dose measurements. Results: IMRT and VMAT simulations were performed and good agreement results were observed for measured and MC dose comparison. Gamma analysis with a 3% dose and 3 mm DTA criteria shows a mean gamma index value of 95% for the studied cases. Conclusion: A Monte Carlo-based dose calculation system has been successfully implemented in a cloud environment. The developed system can be used for independent dose verification of IMRT and VMAT plans in routine clinical practice. The system will also be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems. This work was supported by JSPS KAKENHI Grant Number 25861057

  8. Model dosimetric for Radon and Daughters

    International Nuclear Information System (INIS)

    Puerta, J.A.; Cardenas, H.F.

    1998-01-01

    You elaborates a model dosimetric for radon and their products of decline of short half life starting from the new model of the breathing tract of the publication 66 of the ICRP and the use of the systemic models proposed in the publication 67, 68 and 69 of the same commission. The correlated used methodology the incorporation of these radionuclides with the activity in organs and you excrete, considering the difference of metabolic behavior of the products of decline and of their predecessor

  9. Dosimetric investigations in mammography

    International Nuclear Information System (INIS)

    Metges, P.J.; Lorrain, S.

    1981-01-01

    The development film-screen detectors in radiological equipment has led us to study how to improve standard mammographic pictures (focus 0.3 x 0.3 mm, focus-film distance: 65) of thick and dense breasts by the use of an anti-scatter grid and by magnification. A dosimetric study was necessary to assess the doses delivered during mammographic examinations carried out according to various procedures. The results led to modify breast examination procedures and use an anti-scatter grid for breasts thicker than 4 cm or known as dense. The dose increase due to a better quality image is the lowest provided depth penetration is increased by 2 kV as compared to a standard picture. Absorbed doses on the X-ray axis, at 3 cm depth, are below 0.1 rad [fr

  10. SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

    International Nuclear Information System (INIS)

    Keeling, V; Jin, H; Ali, I; Ahmad, S

    2014-01-01

    Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin, Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion

  11. 78 FR 52694 - Price Cap Rules for Certain Postal Rate Adjustments

    Science.gov (United States)

    2013-08-26

    ... Service outlined the basic concept that eventually formed the basis of Sec. 3010.23(d).\\20\\ The Postal... Establishing a System of Ratemaking, January 30, 2007 (Order No. 2). \\20\\ Docket No. RM2007-1, Reply Comments.... RM2007-1, Second Advance Notice of Proposed Rulemaking on Regulations Establishing a System of Ratemaking...

  12. Loading pattern calculated by inverse optimization vs traditional dosimetry systems of intracavitary brachytherapy of cervical cancer: a dosimetric study

    International Nuclear Information System (INIS)

    Jamema, S.V.; Deshpande, D.D.; Kirisits, C.; Trnkova, P.; Poetter, R.; Mahantshetty, U.; Shrivastava, S.K.; Dinshaw, K.A.

    2008-01-01

    In the recent past, inverse planning algorithms were introduced for intracavitary brachytherapy planning (ICBT) for cervical cancer. The loading pattern of these algorithms in comparison with traditional systems may not be similar. The purpose of this study was to objectively compare the loading patterns of traditional systems with the inverse optimization. Based on the outcome of the comparison, an attempt was made to obtain a loading pattern that takes into account the experience made with the inverse optimization

  13. Application of Pareto's Method in Analysing Postal Service Quality

    Directory of Open Access Journals (Sweden)

    Elizabeta Kovač-Striko

    2012-10-01

    Full Text Available The basic aim of control in postal traffic is to insure high-quality se1vices for customers. The paper presents the analysisof quality control in collecting postal items, based on the dataobtained during the control performed by the internal ControlService in the postal centre for international traffic Zagreb. Thepaper also offers some measures for the improvement of thequality of services.

  14. Dosimetric properties of MOS transistors

    International Nuclear Information System (INIS)

    Frank, H.; Petr, I.

    1977-01-01

    The structure of MOS transistors is described and their characteristics given. The experiments performed and data in the literature show the following dosimetric properties of MOS transistors: while for low gamma doses the transistor response to exposure is linear, it shows saturation for higher doses (exceeding 10 3 Gy in tissue). The response is independent of the energy of radiation and of the dose rate (within 10 -2 to 10 5 Gy/s). The spontaneous reduction with time of the spatial charge captured by the oxide layer (fading) is small and acceptable from the point of view of dosimetry. Curves are given of isochronous annealing of the transistors following irradiation with 137 Cs and 18 MeV electrons for different voltages during irradiation. The curves show that in MOS transistors irradiated with high-energy electrons the effect of annealing is less than in transistors irradiated with 137 Cs. In view of the requirement of using higher temperatures (approx. 400 degC) for the complete ''erasing'' of the captured charge, unsealed systems must be used for dosimetric purposes. The effect was also studied of neutron radiation, proton radiation and electron radiation on the MOS transistor structure. For MOS transistor irradiation with 14 MeV neutrons from a neutron generator the response was 4% of that for gamma radiation at the same dose equivalent. The effect of proton radiation was studied as related to the changes in MOS transistor structure during space flights. The response curve shapes are similar to those of gamma radiation curves. The effect of electron radiation on the MOS structure was studied by many authors. The experiments show that for each thickness of the SiO 2 layer an electron energy exists at which the size of the charge captured in SiO 2 is the greatest. All data show that MOS transistors are promising for radiation dosimetry. The main advantage of MOS transistors as gamma dosemeters is the ease and speed of evaluation, low sensitivity to neutron

  15. Career Education Program: Geneva Area City Schools. [Grade 2 Units: Postal Services, Our Homes, Clothing, Community Helpers, and Custodians In Our Lives].

    Science.gov (United States)

    Geneva Area City Schools, OH.

    Five curriculum units for the second grade level focus on: (1) clothing producers and suppliers, and the clothing industry; (2) postal service workers and the postal system; (3) janitorial workers; (4) workers who build, furnish, and maintain homes and the housing industry; and (5) various community workers. Behavioral unit objectives emphasize…

  16. The computer system for registration and dosimetric control of inhabitants, cosmonauts and pilots from the different radiation sources

    International Nuclear Information System (INIS)

    Lebedev, L.A.; Koniaev, S.V.; Mikheenko, S.G.; Rusin, S.V.; Sidorin, V.P.

    1996-01-01

    Cosmonauts, pilots and inhabitants living near the nuclear power plants or nuclear facilities are particular group of risk. To estimate the radiation risk for this limited part of population the Computer System was developed. The main purpose of this System is registration, account, storage, processing, analysis, forecasting and control both doses and radiation risks for each person. Both experimental and calculated data are used in the Computer System. The experimental data are used in case of estimation of doses received by cosmonauts during space flight and by pilots during the flight in atmosphere. The System allows to calculate the doses for each person from any type of medical procedures including the X-ray diagnostic examinations and radioisotopic diagnostics. The Computer System also allows to calculate the radiation exposure of inhabitants living near nuclear facilities both in case of normal exploitation and different kind of accidents. The annual dose distribution from different types of radiation sources are given. It was shown that doses from medical irradiation are comparable or sometime higher than the doses from space flight, air flight or nuclear accident. (author)

  17. Dosimetric verification of IMRT plans

    International Nuclear Information System (INIS)

    Bulski, W.; Cheimicski, K.; Rostkowska, J.

    2012-01-01

    Intensity modulated radiotherapy (IMRT) is a complex procedure requiring proper dosimetric verification. IMRT dose distributions are characterized by steep dose gradients which enable to spare organs at risk and allow for an escalation of the dose to the tumor. They require large number of radiation beams (sometimes over 10). The fluence measurements for individual beams are not sufficient for evaluation of the total dose distribution and to assure patient safety. The methods used at the Centre of Oncology in Warsaw are presented. In order to measure dose distributions in various cross-sections the film dosimeters were used (radiographic Kodak EDR2 films and radiochromic Gafchromic EBT films). The film characteristics were carefully examined. Several types of tissue equivalent phantoms were developed. A methodology of comparing measured dose distributions against the distributions calculated by treatment planning systems (TPS) was developed and tested. The tolerance level for this comparison was set at 3% difference in dose and 3 mm in distance to agreement. The so called gamma formalism was used. The results of these comparisons for a group of over 600 patients are presented. Agreement was found in 87 % of cases. This film dosimetry methodology was used as a benchmark to test and validate the performance of commercially available 2D and 3D matrices of detectors (ionization chambers or diodes). The results of these validations are also presented. (authors)

  18. Contribution to the study of a dosimetric system adapted to the utilization of ionization processes in food and agroindustry

    International Nuclear Information System (INIS)

    Marchioni, E.

    1989-11-01

    The obtention of reliable and accurate measurement of the radiation dose transmitted to the matter after ionization is investigated. The importance of the study comes from the fact that the success of a radiation treatment depends on the accurate monitoring of the radiation doses. The principles and the definition of the physical coefficients required for calculating the radiation dose in the matter are reviewed. The monitoring of the physical parameters of the experimental devices is discussed. The experimental system developed and constructed in this study is described. The main characteristics of dose measurement systems are analyzed. Two techniques allowing the measurement of the radiation dose, which remains in the product after irradiation are presented [fr

  19. 39 CFR 4.5 - Assistant Postmasters General, General Counsel, Judicial Officer, Chief Postal Inspector.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Assistant Postmasters General, General Counsel, Judicial Officer, Chief Postal Inspector. 4.5 Section 4.5 Postal Service UNITED STATES POSTAL SERVICE THE... Counsel, a Judicial Officer, a Chief Postal Inspector, and such number of officers, described in 39 U.S.C...

  20. 39 CFR 762.30 - Disbursement postal money orders issued to incompetent payees.

    Science.gov (United States)

    2010-07-01

    ... shall be forwarded to the Money Order Division, Postal Data Center, P.O. Box 14963, St. Louis, MO 63182... 39 Postal Service 1 2010-07-01 2010-07-01 false Disbursement postal money orders issued to... OBLIGATIONS; DISBURSEMENT POSTAL MONEY ORDERS DISBURSEMENT POSTAL MONEY ORDERS Endorsements, Payment...

  1. 39 CFR 762.31 - Disbursement postal money orders issued to deceased payees.

    Science.gov (United States)

    2010-07-01

    ... should be returned to the Money Order Division, Postal Data Center, P.O. Box 14963, St. Louis, MO 63182... 39 Postal Service 1 2010-07-01 2010-07-01 false Disbursement postal money orders issued to... OBLIGATIONS; DISBURSEMENT POSTAL MONEY ORDERS DISBURSEMENT POSTAL MONEY ORDERS Endorsements, Payment...

  2. 39 CFR 762.28 - Release of original disbursement postal money orders.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Release of original disbursement postal money... and Processing of Disbursement Postal Money Orders § 762.28 Release of original disbursement postal money orders. An original Disbursement Postal Money Order may be released to a responsible endorser only...

  3. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products; Sistemas dosimetricos de altas dosis, tasa de dosis y uniformidad de dosis en alimentos y producto medico

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, J.; Vivanco, M.; Castro, E., E-mail: jvargas@ipen.gob.pe [Instituto Peruano de Energia Nuclear, Av. Canada 1470, San Borja, Lima (Peru)

    2014-08-15

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  4. Postal dosimetry audit test for small photon beams

    International Nuclear Information System (INIS)

    Espinosa, María del Mar; Núñez, Luis; Muñiz, José Luis; Lagares, Juan Ignacio; Embid, Miguel; Gómez-Ros, José María

    2012-01-01

    Background and purpose: Small radiation beams ( 3 ) of TLD-100 inserted at 5 and 10 cm of depth in a cylindrical PMMA phantom designed for this purpose. This experimental system is mailed to the audited centres to be irradiated with beams of 1 and 3 cm of side or diameter. The prescribeddose is 1.5 Gy at 10 cm. The properties of this system were studied experimentally and by Monte Carlo (MC) simulation, before the external test. Results: Deviations between the prescribed and measured absorbed doses are below 5% for 69% (1 × 1 cm 2 beam) and 64% (3 × 3 cm 2 beam) of the audited centres. When deviations are above 5%, their causes have been investigated and led to corrections. Conclusion: The developed postal audit is suitable to verify the absorbed doses in small photon beams with an accuracy of 2.9% (1s).

  5. Dosimetric inter-institutional comparison in European radiotherapy centres: Results of IAEA supported treatment planning system audit.

    Science.gov (United States)

    Gershkevitsh, Eduard; Pesznyak, Csilla; Petrovic, Borislava; Grezdo, Joseph; Chelminski, Krzysztof; do Carmo Lopes, Maria; Izewska, Joanna; Van Dyk, Jacob

    2014-05-01

    One of the newer audit modalities operated by the International Atomic Energy Agency (IAEA) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried out in eight European countries - Estonia, Hungary, Latvia, Lithuania, Serbia, Slovakia, Poland and Portugal. The corresponding results are presented. The TPS audit reviews the dosimetry, treatment planning and radiotherapy delivery processes using the 'end-to-end' approach, i.e. following the pathway similar to that of the patient, through imaging, treatment planning and dose delivery. The audit is implemented at the national level with IAEA assistance. The national counterparts conduct the TPS audit at local radiotherapy centres through on-site visits. TPS calculated doses are compared with ion chamber measurements performed in an anthropomorphic phantom for eight test cases per algorithm/beam. A set of pre-defined agreement criteria is used to analyse the performance of TPSs. TPS audit was carried out in 60 radiotherapy centres. In total, 190 data sets (combination of algorithm and beam quality) have been collected and reviewed. Dosimetry problems requiring interventions were discovered in about 10% of datasets. In addition, suboptimal beam modelling in TPSs was discovered in a number of cases. The TPS audit project using the IAEA methodology has verified the treatment planning system calculations for 3D conformal radiotherapy in a group of radiotherapy centres in Europe. It contributed to achieving better understanding of the performance of TPSs and helped to resolve issues related to imaging, dosimetry and treatment planning.

  6. A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform.

    Science.gov (United States)

    Tryggestad, E; Armour, M; Iordachita, I; Verhaegen, F; Wong, J W

    2009-09-07

    Our group has constructed the small animal radiation research platform (SARRP) for delivering focal, kilo-voltage radiation to targets in small animals under robotic control using cone-beam CT guidance. The present work was undertaken to support the SARRP's treatment planning capabilities. We have devised a comprehensive system for characterizing the radiation dosimetry in water for the SARRP and have developed a Monte Carlo dose engine with the intent of reproducing these measured results. We find that the SARRP provides sufficient therapeutic dose rates ranging from 102 to 228 cGy min(-1) at 1 cm depth for the available set of high-precision beams ranging from 0.5 to 5 mm in size. In terms of depth-dose, the mean of the absolute percentage differences between the Monte Carlo calculations and measurement is 3.4% over the full range of sampled depths spanning 0.5-7.2 cm for the 3 and 5 mm beams. The measured and computed profiles for these beams agree well overall; of note, good agreement is observed in the profile tails. Especially for the smallest 0.5 and 1 mm beams, including a more realistic description of the effective x-ray source into the Monte Carlo model may be important.

  7. A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform

    Energy Technology Data Exchange (ETDEWEB)

    Tryggestad, E; Armour, M; Wong, J W [Deptartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD (United States); Iordachita, I [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD (United States); Verhaegen, F [Department of Radiation Oncology (MAASTRO Physics), GROW School, Maastricht University Medical Center, Maastricht (Netherlands)

    2009-09-07

    Our group has constructed the small animal radiation research platform (SARRP) for delivering focal, kilo-voltage radiation to targets in small animals under robotic control using cone-beam CT guidance. The present work was undertaken to support the SARRP's treatment planning capabilities. We have devised a comprehensive system for characterizing the radiation dosimetry in water for the SARRP and have developed a Monte Carlo dose engine with the intent of reproducing these measured results. We find that the SARRP provides sufficient therapeutic dose rates ranging from 102 to 228 cGy min{sup -1} at 1 cm depth for the available set of high-precision beams ranging from 0.5 to 5 mm in size. In terms of depth-dose, the mean of the absolute percentage differences between the Monte Carlo calculations and measurement is 3.4% over the full range of sampled depths spanning 0.5-7.2 cm for the 3 and 5 mm beams. The measured and computed profiles for these beams agree well overall; of note, good agreement is observed in the profile tails. Especially for the smallest 0.5 and 1 mm beams, including a more realistic description of the effective x-ray source into the Monte Carlo model may be important.

  8. Electronic tissue compensation achieved with both dynamic and static multileaf collimator in eclipse treatment planning system for Clinac 6 EX and 2100 CD Varian linear accelerators: Feasibility and dosimetric study

    Directory of Open Access Journals (Sweden)

    Kinhikar Rajesh

    2007-01-01

    Full Text Available Dynamic multileaf collimator (DMLC and static multileaf collimator (SMLC, along with three-dimensional treatment planning system (3-D TPS, open the possibility of tissue compensation. A method using electronic tissue compensator (ETC has been implemented in Eclipse 3-D TPS (V 7.3, Varian Medical Systems, Palo Alto, USA at our center. The ETC was tested for head and neck conformal radiotherapy planning. The purpose of this study was to verify the feasibility of DMLC and SMLC in head and neck field irradiation for delivering homogeneous dose in the midplane at a pre-defined depth. In addition, emphasis was given to the dosimetric aspects in commissioning ETC in Eclipse. A Head and Neck Phantom (The Phantom Laboratory, USA was used for the dosimetric verification. Planning was carried out for both DMLC and SMLC ETC plans. The dose calculated at central axis by eclipse with DMLC and SMLC was noted. This was compared with the doses measured on machine with ion chamber and thermoluminescence dosimetry (TLD. The calculated isodose curves and profiles were compared with the measured ones. The dose profiles along the two major axes from Eclipse were also compared with the profiles obtained from Amorphous Silicon (AS500 Electronic portal imaging device (EPID on Clinac 6 EX machine. In uniform dose regions, measured dose values agreed with the calculated doses within 3%. Agreement between calculated and measured isodoses in the dose gradient zone was within 3 mm. The isodose curves and the profiles were found to be in good agreement with the measured curves and profiles. The measured and the calculated dose profiles along the two major axes were flat for both DMLC and SMLC. The dosimetric verification of ETC for both the linacs demonstrated the feasibility and the accuracy of the ETC treatment modality for achieving uniform dose distributions. Therefore, ETC can be used as a tool in head and neck treatment planning optimization for improved dose uniformity.

  9. Dosimetric essay in dental radiology

    International Nuclear Information System (INIS)

    Lopez Salaberry, M.

    1998-01-01

    A neck study was observated in the tiroids glands,laryngeal zone, sensitive organs for the ionizing radiation for increase dental xray exams. Was selected 29th patients with radiography prescription complete (in the Odontology Faculty Clinics Uruguaian). It took radiographies with and without tiroids necklace and apron lead using dosemeters. Dosimetric studies had demonstrated good dose between patients. For measuring the radiation dose have been used TLD thermoluminescence dosimetric and Harshaw 6600 for read it. The thyroids necklace use and odontology postgrading for training course for dentistry was the two recommendations advised

  10. Accuracy of out-of-field dose calculation of tomotherapy and Cyberknife treatment planning systems. A dosimetric study

    International Nuclear Information System (INIS)

    Schneider, Uwe; Hirslanden Medical Center, Aarau; Haelg, Roger A.; Hartmann, Matthias; Mack, Andreas; Storelli, Fabrizio; Besserer, Juergen; Joosten, Andreas; Moeckli, Raphael

    2014-01-01

    Purpose: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. Materials and methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. Results: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40 cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10 cm from the PTV border the Tomotherapy up to 35 cm. Conclusions: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35 cm from the PTV border (for a 390 cm 3 large PTV). (orig.)

  11. 39 CFR 232.1 - Conduct on postal property.

    Science.gov (United States)

    2010-07-01

    ... promotion of social welfare but do not participate or intervene in any political campaign on behalf of any candidate or political party for any public office. (ii) Absolutely no partisan or political literature may... that will protect Postal Service property. (3) Postal Inspectors, Office of Inspector General Criminal...

  12. 76 FR 12141 - New Postal Product and New Price Category

    Science.gov (United States)

    2011-03-04

    ... Service will be available with Express Mail, Priority Mail and Parcel Select for commercial and online customers only. The Postal Service includes the following attachments with its Request: Attachment A... Commission is noticing a recently-filed Postal Service request to add Competitive Ancillary Services to the...

  13. 77 FR 64362 - Postal Rate and Classification Changes

    Science.gov (United States)

    2012-10-19

    .... Promotions As part of this filing, the Postal Service seeks approval of six promotions during calendar year.... Table 6--First-Class Mail Price Changes Percent First-class mail product change Single-Piece Letters and...-piece letter mail (including the Forever stamp), increases by one cent under the Postal Service's plan...

  14. ORGANIZATIONAL DEVELOPMENT IN THE FIELD OF POSTAL SERVICES

    Directory of Open Access Journals (Sweden)

    Sirbu Janetta

    2013-07-01

    The evaluation of organizational development at the County Postal Office in Cluj was made by applying a questionnaire on organizational development that consists of 60 descriptive statements, answered by four of the organization\\'s management and 56 employees with executive positions. Following the results obtained from the questionnaires there has been showed that the organization is in phase two of development that is leadership development. The applied management style starts to be on odds with reality and triggers the crisis of autonomy, which requires delegation of authority and responsibilities to as many employees as possible, involvement and encouragement of initiatives of the staff. After analyzing the questionnaire responses, it was revealed that the organization is in the second phase of development, respectively development through leadership, requiring an authorized leader to streamline the activity and to create major necessary budgeting systems of reward and communication.

  15. Quality control of dosimetric systems using thermoluminescent crystals; Control de calidad de un sistema de planeacion dosimetrico utilizando cristales termoluminiscentes y su aplicacion en tratamientos de pacientes con cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Mahecha, L.; Plazas, M. C.; Machado, M.; Perea, M. D.

    2006-07-01

    To achieve an optimal tumoral control to prostate cancer in early and locally advanced stages, it is necessary to increase the dose with a low mobility probability at the vesicle an rectal level. This is achieved through conformal radiotherapy. The Instituto Nacional de Cancerologia uses this technique, but two questions arise from the medical-physicists and medical radio-oncologist: In accordance with clinical protocols, the conformal radiotherapy delivers a low dose to the adjacent healthy tissues. What experimental method exists that can prove with certainly the veracity of this affirmation?. And, Do the dosimetric simulation system calculate suitable the dose for each tissues?. Through thermoluminescent dosimetry and the use of a physical simulator,we measured the absorbed dose at the target volume and the adjacent tissues using conformal and conventional radiotherapy. We proved that organs such as the rectum and bladder, receiver a minor dose in conformal radiotherapy, hence reducing their mobility probability. In addition, the readings from the thermoluminescent dosimeters and the doses calculated by the ECLIPSE dosimetric system were compared, concluding that the patient's prescribed dose is effectively delivered as recommended by the quality control program in radiotherapy. (Author)

  16. U.S. Postal Service: Deteriorating Financial Outlook Increases Need for Transformation

    National Research Council Canada - National Science Library

    2002-01-01

    .... The combined effect of these events and the current economic slowdown have served to further exacerbate USPS's financial difficulties by decreasing postal revenues, while postal costs continued...

  17. 39 CFR 762.27 - Processing of disbursement postal money orders by Federal Reserve Banks.

    Science.gov (United States)

    2010-07-01

    ..., and its other depositors which guarantee all prior endorsements thereon; (2) Give immediate credit... DEBT OBLIGATIONS; DISBURSEMENT POSTAL MONEY ORDERS DISBURSEMENT POSTAL MONEY ORDERS Endorsements...

  18. A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Son, Jaeman; Baek, Taesung; Lee, Boram; Shin, Dongho; Park, Sung Yong; Park, Jeonghoon; Lim, Young Kyung; Lee, Se Byeong; Kim, Jooyoung; Yoon, Myonggeun

    2015-01-01

    This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA

  19. A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy.

    Science.gov (United States)

    Son, Jaeman; Baek, Taesung; Lee, Boram; Shin, Dongho; Park, Sung Yong; Park, Jeonghoon; Lim, Young Kyung; Lee, Se Byeong; Kim, Jooyoung; Yoon, Myonggeun

    2015-09-01

    This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA.

  20. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE; Um sistema dosimetrico de referencia para o intervalo de doses da radioterapia baseado na alanina/RPE

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rodrijr@net.ipen.br

    2001-07-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10{sup 5} Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  1. Human resource management in the delivery of postal items

    Directory of Open Access Journals (Sweden)

    Kujačić Momčilo D.

    2015-01-01

    Full Text Available Delivery of postal items is the last phase in the postal conveyance process. This phase involved up to 57% in total costs of postal items conveyance. In order to reduce the costs of delivery phase, postal organizations apply different methods and techniques. Legal and technological regulations, various restrictions regarding the selection and deployment of employees influence the choice of appropriate methods. Also, the principle of availability of the universal postal service is an essential factor in defining the optimal model. In this paper, the model for assessing and planning of the number of employees in the delivery service observed postal operator has been proposed, with respect to the principles of productivity and accessibility constraints of the universal postal service. This paper will analyze the impact of daily fluctuations in the number of full-time employees and the possibility of hiring a part-time workers in the days with increased traffic volume in the delivery of items, when usually the items from large customers are delivered.

  2. Dosimetric monitoring at time of Chernobyl clean-up. A retrospective view

    International Nuclear Information System (INIS)

    Chumak, V.V.; Bakhanova, E.V.; Musijachenko, N.V.; Krjuchkov, V.P.

    2000-01-01

    Although at time of the accident many thousands of individuals were subjected to personal dosimetric monitoring, a status of dosimetric support of clean-up activities performed in 1986-1987 remains one of the most uncertain radiological issues related to Chernobyl accident. It is known that the scope, practical coverage and methodologies of dosimetry at time of the accident significantly varied. Unfortunately, the dose records available now in a number registries and databases are lacking direct indications of the methods of dosimetry, locations of work and tasks performed by liquidators. Moreover, data record linkage in many cases is problematic due to lack of unique identifiers in the databases of concern. However, this information, collected in course of dosimetric monitoring is extremely valuable for epidemiological consideration of this cohort and, therefore, cannot be neglected because of problems with strait forward application of this data. Retrospective consideration of dosimetric monitoring data was conducted along several lines. First, data sets (in some cases impersonal), related to the known dosimetric practices were studied in order to determine regularities in their dose distributions, evaluate possible distortions caused by extraneous admixtures to dose arrays and evaluate possible contribution of falsified dose records. Another effort was directed towards individualization of information regarding affiliation and tasks of the liquidators included into the State Chernobyl Registry (SCR), which is, essentially, the main pool of subjects for observation in the framework of post Chernobyl epidemiological studies. The SCR in its original shape was missing this crucial information. In order to recover this information gap, a wide scale postal survey of liquidators was undertaken. Those persons who are included into the State Chernobyl Registry and have official dose records were asked to respond to a simple five-entry questionnaire, dealing with their

  3. 39 CFR 761.8 - Servicing book-entry Postal Service securities; payment of interest, payment at maturity or upon...

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Servicing book-entry Postal Service securities... POSTAL SERVICE POSTAL SERVICE DEBT OBLIGATIONS; DISBURSEMENT POSTAL MONEY ORDERS BOOK-ENTRY PROCEDURES § 761.8 Servicing book-entry Postal Service securities; payment of interest, payment at maturity or upon...

  4. 39 CFR 222.1 - Authority to administer postal affairs.

    Science.gov (United States)

    2010-07-01

    ..., or in any other Postal Service employee. (b) Corporate officers. Corporate officers are authorized to... matters within their areas of responsibility, except as limited by law or by the specific terms of their...

  5. 75 FR 69143 - Postal Rate and Classification Changes

    Science.gov (United States)

    2010-11-10

    ..., Pricing Strategy, as the official available to provide prompt responses to requests for clarification from..., at 30. II. Postal Service Filing Reply Rides Free. This pricing initiative is available for mailers...

  6. Violence and stress at work in the postal sector

    OpenAIRE

    Giga, Sabir I; Hoel, Helge; Cooper, Cary L

    2003-01-01

    Reviews literature on the prevalence, causes and consequences of violence and stress within the postal sector and presents examples of good practice and relevant sources of information to guide practitioners and researchers.

  7. 78 FR 12108 - New Postal Product; Negotiated Service Agreement

    Science.gov (United States)

    2013-02-21

    .... Introduction II. Contents of Filing III. Ordering Paragraphs I. Introduction On February 13, 2013, the Postal... unredacted amendment under seal. It asserts that the ``supporting financial documentation and financial...

  8. The Postal Acceptance Rule in the Digital Age

    OpenAIRE

    Al Ibrahim, Marwan; Ababneh, Ala’eldin; Tahat, Hisham

    2007-01-01

    This article examines the application of the postal acceptance rule to email acceptances. Differentviews have been argued against the application of traditional rule like the postal acceptance rule, which wasestablished in 1818 as a legal norm in contract formation to modern communications like the email. The paperpresents the arguments and rationale behind the application of this rule and contends its applicability to themodern communication via e-mail. The paper posits that email is not an ...

  9. Sun safety knowledge and practice in UK postal delivery workers

    OpenAIRE

    Houdmont, J.; Davis, S.; Griffiths, A.

    2015-01-01

    Background: Postal delivery workers spend a large proportion of their work time outdoors, placing them at increased risk for skin cancer. To date, no studies have examined occupational sun safety knowledge and practice within this group in the UK.\\ud Aims: To describe the occupational sun safety knowledge and practice of UK postal delivery workers and to investigate the association of demographic, personal and occupational factors with knowledge and practice in order to identify potential str...

  10. 78 FR 67951 - Price Cap Rules for Certain Postal Rate Adjustments; Corrections

    Science.gov (United States)

    2013-11-13

    ... POSTAL REGULATORY COMMISSION 39 CFR Part 3010 [Docket No. RM2013-2; Order No. 1786] Price Cap Rules for Certain Postal Rate Adjustments; Corrections AGENCY: Postal Regulatory Commission. ACTION: Correcting amendments. SUMMARY: The Postal Regulatory Commission published a document in the Federal Register...

  11. 39 CFR 762.25 - Reclamation of amounts of paid disbursement postal money orders.

    Science.gov (United States)

    2010-07-01

    ... paid disbursement postal money orders. The Postal Service shall have the right to demand refund from the presenting bank of the amount of a paid Disbursement Postal Money Order if after payment the... another for a deceased payee where the right to the proceeds of such Disbursement Postal Money Orders...

  12. 39 CFR 762.29 - Endorsement of disbursement postal money orders by payees.

    Science.gov (United States)

    2010-07-01

    ... authorization, the financial organization may use an endorsement substantially as follows: Credit to the account... 39 Postal Service 1 2010-07-01 2010-07-01 false Endorsement of disbursement postal money orders by...; DISBURSEMENT POSTAL MONEY ORDERS DISBURSEMENT POSTAL MONEY ORDERS Endorsements, Payment, Guaranties, Warranties...

  13. Practical realisation of individual dosimetric control of internal and external irradiation during works at 'Ukrytie' shelter

    International Nuclear Information System (INIS)

    Likhtarev, I.A.; Bondarenko, O.S.; Berkovskij, V.B.; Chumak, V.K.; Korneev, A.A.; Dmitrienko, A.V.

    1999-01-01

    Individual dosimetric control requires the minimisation of personnel irradiation doses and needs forecasting and planning of dose loads. System of individual dose control and its functions at 'Ukrytie' shelter are described

  14. Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system

    International Nuclear Information System (INIS)

    Ding Meisong; Newman, Francis M.S.; Kavanagh, Brian D.; Stuhr, Kelly M.S.; Johnson, Tim K.; Gaspar, Laurie E.

    2006-01-01

    Purpose: To investigate the dosimetric differences among three-dimensional conformal radiotherapy (3D-CRT), dynamic conformal arc therapy (DCAT), and intensity-modulated radiotherapy (IMRT) for brain tumor treatment. Methods and Materials: Fifteen patients treated with Novalis were selected. We performed 3D-CRT, DCAT, and IMRT plans for all patients. The margin for the planning target volume (PTV) was 1 mm, and the specific prescription dose was 90% for all plans. The target coverage at the prescription dose, conformity index (CI), and heterogeneity index were analyzed for all plans. Results: For small tumors (PTV ≤2 cm 3 ), the three dosimetric parameters had approximate values for both 3D-CRT and DCAT plans. The CI for the IMRT plans was high. For medium tumors (PTV >2 to ≤100 cm 3 ), the three plans were competitive with each other. The IMRT plans had a greater CI, better target coverage at the prescription dose, and a better heterogeneity index. For large tumors (PTV >100 cm 3 ), the IMRT plan had good target coverage at the prescription dose and heterogeneity index and approximate CI values as those in the 3D-CRT and DCAT plans. Conclusion: The results of our study have shown that DCAT is suitable for most cases in the treatment of brain tumors. For a small target, 3D-CRT is useful, and IMRT is not recommended. For larger tumors, IMRT is superior to 3D-CRT and very competitive in sparing critical structures, especially for big tumors

  15. Personal dosimetric monitoring in Ukraine: current status and further development

    International Nuclear Information System (INIS)

    Chumak, V. V.; Musijachenkom, A. V.; Boguslavskaya, A. I.

    2003-01-01

    Presently Ukraine has mixed system for dosimetric monitoring. Nuclear power plants and some major nuclear facilities have their own dosimetry services, which are responsible for regular dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by dosimetry laboratories affiliated to the territorial authorities for sanitary and epidemiology supervision. In 2002-2003 Ukrainian Ministry of Health performed survey of the status of dosimetric monitoring and inventory of critical groups requiring such monitoring. Dosimetry services in Ukraine cover about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca.12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services operate in 13 of 24 regions of Ukraine, using DTU-01 manual TLD readers produced with one exception in 1988-1990. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38% to 100% depending on the region. Personnel of nuclear power plants (about 16,400 workers) is monitored by their own dosimetry services achieving absolute coverage of the main staff and temporary workers. Current inadequate status of dosimetric monitoring infrastructure in Ukraine demands an urgent elaboration of the united state system for monitoring and recording of individual doses. The proposed plan would allows to bring dosimetry infrastructure in Ukraine to the modern state which would be compatible with existing and future European and international radiation protection networks. Unitary structure of Ukraine, strong administrative command and good communications between regions of the country are positive factors in favour of efficient implementation of the proposed plan. Deficiencies are associated with limited funding of this effort. (authors)

  16. Dosimetric survey in industrial irradiators and dosimetric systems calibration

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Correa, Ricardo Ferracini; Oliveira, Paulo Marcio C. de

    2005-01-01

    The work seeks the collecting of dose rate points for irradiation research plants and calibration of commercial dosimeters, using dosimeters standard references. Using the obtained data is possible to determine the absorbed doses in any point of an irradiation room, assuring the value of absorbed dose in the irradiated product, with the use of the commercial dosimeters. The commercial dosimeters used in this work are polymethylmethacrylate (PMMA), and the reference dosimeters used are Fricke's solution. Among the advantages of the accomplishment of this work, it can stand out the quality assurance of the services rendered by Centro de Desenvolvimento da Tecnologia Nuclear to their customers and to the society, in the purpose of optimization of exposition time of the irradiated products, in way to guarantee the absorbed doses in each irradiated material with a good precision

  17. Dosimetric methodology of the ICRP

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    1994-01-01

    Establishment of guidance for the protection of workers and members of the public from radiation exposures necessitates estimation of the radiation dose to tissues of the body at risk. The dosimetric methodology formulated by the International Commission on Radiological Protection (ICRP) is intended to be responsive to this need. While developed for radiation protection, elements of the methodology are often applied in addressing other radiation issues; e.g., risk assessment. This chapter provides an overview of the methodology, discusses its recent extension to age-dependent considerations, and illustrates specific aspects of the methodology through a number of numerical examples

  18. Thermoluminescent dosimetric properties of Descalvado sand

    International Nuclear Information System (INIS)

    Teixeira, M.I.; Caldas, L.V.E.

    2006-01-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ( 60 Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  19. Thermoluminescent dosimetric properties of Descalvado sand

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M.I.; Caldas, L.V.E

    2006-07-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ({sup 60} Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  20. Laminated dosimetric card

    International Nuclear Information System (INIS)

    Cox, F.M.; Chamberlain, J.D.; Shrader, E.F.; Shoffner, B.M.; Szalanczy, A.

    1975-01-01

    A laminated card with one or more apertures, each adapted to peripherally seal an encapsulated dosimeter, is formed by bonding a foraminous, code-adaptable, rigid sheet of low-Z material with a codedly transparent sheet of low-Z material in light-transmitting registry with particular code-holes of the rigid sheet. The laminated card may be coded to identify the person carrying it, and/or the location or circumstances related to its exposure to radiation. This card is particularly adapted for use in an instrument capable of evaluating a multiplicity of cards, substantially continuously. The coded identification from the card may be displayed by an appropriate machine, and if desired an evaluation may be recorded because of a ''parity checking'' system incorporated in each card, which permits ''auto-correction.'' Alternatively, where means for effecting the correction automatically are available, the operation of the machine may be interrupted to permit visual examination of a rejected card. The card of this invention is also coded for identifying the type of card with respect to its specific function, and whether or not a card is correctly positioned at any predetermined location during its sequential progress through the instrument in which it is evaluated. Dosimeters are evaluated and the card identified in one pass through the instrument. (auth)

  1. Digital chest radiography system with amorphous selenium flat-panel detectors: qualitative and dosimetric comparison with a dedicated film-screen system

    International Nuclear Information System (INIS)

    Prato, Antonio; Fava Cesare; Ropolo, Roberto

    2005-01-01

    Purpose. To compare the quality and radiation dose of a conventional film-screen system and a digital system with amorphous selenium detectors in the study of the chest, by verifying overall performance and exposure levels for the main chest structures in patients of different sizes. Materials and methods. An analogic system (Chest Changer, Dupont, Day-light model 1000) and a digital system (Directray Rad 1000C, Hologic) were tested on a total of 1000 patients randomly assigned to one of two groups of 500 subjects.The patients were further subdivided according to BMI (Body Mass Index). Image quality was determined by two chest radiologists who evaluated eight anatomical structures. The entrance surface dose (skin-dose), calculated based on the exposure parameters, was taken as the patient dose. Results. Mean dose delivered was very similar for both techniques in the PA view (0.28 mGy), but it was greater in the LL projections obtained with the digital system (1.20 rnGy versus 0.83 mGy). The highest overall scores were assigned to 43% and 23.2% analogic radiograms and 64% and 70.2% digital radiograms, for the PA and LL projections respectively. The scores assigned to the various anatomical structures confirmed the better performance of the digital system in almost all of the regions considered. Conclusions. The mean quality of radiograms is definitely higher with the digital system, in particular in the LL projections, where the higher patient doses are counterbalanced by fewer repeated scans. The greater level of exposure in the digital system appears nonetheless tolerable on account of the greater informativeness and therefore diagnostic gain and also considering the possibilities for improving the system [it

  2. Comparative analysis of customer satisfaction in postal and banking services

    Directory of Open Access Journals (Sweden)

    Ratković Milijanka

    2017-01-01

    Full Text Available The goal of this study is a comparative analysis of customer satisfaction towards postal and banking services in Serbia. In addition, this paper should provide guidance on how managements of the Post Office and the Bank should behave on the market. The survey was conducted throughout the whole Serbian territory. The subject of the research is to measure the perception of postal and banking services, in order to assess the quality of services and the impact of expectations on the level of perceived quality. Testing and final conclusions about the level of quality of postal and banking services was carried out on the basis of the existing literature and modified SERVQUAL model.

  3. 39 CFR Appendix A to Part 3002 - Postal Regulatory Commission, Mission Statement of the Office of the Consumer Advocate

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Postal Regulatory Commission, Mission Statement of the Office of the Consumer Advocate A Appendix A to Part 3002 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL ORGANIZATION Pt. 3002, App. A Appendix A to Part 3002—Postal Regulatory Commission, Mission Statement of the Office of the Consumer...

  4. 39 CFR 111.2 - Availability of the Mailing Standards of the United States Postal Service, Domestic Mail Manual.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Availability of the Mailing Standards of the United States Postal Service, Domestic Mail Manual. 111.2 Section 111.2 Postal Service UNITED STATES POSTAL SERVICE POST OFFICE SERVICES [DOMESTIC MAIL] GENERAL INFORMATION ON POSTAL SERVICE § 111.2...

  5. A national dosimetric audit of IMRT

    International Nuclear Information System (INIS)

    Budgell, Geoff; Berresford, Joe; Trainer, Michael; Bradshaw, Ellie; Sharpe, Peter; Williams, Peter

    2011-01-01

    Background and purpose: A dosimetric audit of IMRT has been carried out within the UK between June 2009 and March 2010 in order to provide an independent check of safe implementation and to identify problems in the modelling and delivery of IMRT. Methods and materials: A mail based audit involving film and alanine dosimeters was utilized. Measurements were made for each individual field in an IMRT plan isocentrically in a flat water-equivalent phantom at a depth of 5 cm. The films and alanine dosimeters were processed and analysed centrally; additional ion chamber measurements were made by each participating centre. Results: 57 of 62 centres participated, with a total of 78 plans submitted. For the film measurements, all 176 fields from the less complex IMRT plans (including prostate and breast plans) achieved over 95% pixels passing a gamma criterion of 3%/3 mm within the 20% isodose. For the more complex IMRT plans (mainly head and neck) 8/245 fields (3.3%) achieved less than 95% pixels passing a 4%/4 mm gamma criterion. Of the alanine measurements, 4/78 (5.1%) of the measurements differed by >5% from the dose predicted by the treatment planning system. Three of these were large deviations of -77.1%, -29.1% and 14.1% respectively. Excluding the three measurements outside 10%, the mean difference was 0.05% with a standard deviation of 1.5%. The out of tolerance results have been subjected to further investigations. Conclusions: A dosimetric audit has been successfully carried out of IMRT implementation by over 90% of UK radiotherapy departments. The audit shows that modelling and delivery of IMRT is accurate, suggesting that the implementation of IMRT has been carried out safely.

  6. Verification system development a dosimetric tridimensional using Solution Fricke gel in the application for verification of radiation therapy in arc modulated volumetric (VMAT) in treatment with target moving for breathing

    International Nuclear Information System (INIS)

    Sakuraba, Roberto Kenji

    2015-01-01

    Volumetric Modulated Arc Therapy (VMAT) is one of the methods most commonly used in teletherapy to treat cancer. The various technological advances and the evolution of treatment techniques made the VMAT as one of the state of the art methods for the treatment of some cancers. Part of this improvement is credited to improvements in accuracy and prescription dose absorbed recommended to the patient over the years. This advance allows currently is possible to perform dosimetric calculations by means of the computerized planning system, considering the heterogeneity of patients, such as tissues and organs with different water compositions medium (reference radiation), and individual patient contour the movement of tumors breathing. Such advances require quality control of these tools, in order to ensure that the entire treatment process is satisfactory and accurate. Up to now, the community lacks an experimental system capable of evaluating, considering the uncertainty levels if the computerized planning systems are able to consider the movement of targets in the treatments with VMAT. In this paper, will be presented the results obtained with the phantom Fricke Xylenol Gel, capable of measuring the differences introduced by movement using the Magnetic Resonance Image - MRI and compared qualitatively and quantitatively. The main stages of the phantom development, their experimental results, conclusions and comparisons with other systems are discussed. (author)

  7. Radiochromic film in the dosimetric verification of intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zhou Yingjuan; Huang Shaomin; Deng Xiaowu

    2007-01-01

    Objective: Objective To investigate the dose-response behavior of a new type of radio- chromic film( GAFCHROMIC EBT) and explore the clinical application means and precision of dosage measurement, which can be applied for: (1) plan-specific dosimetric verification for intensity modulated radiation therapy, (2) to simplify the process of quality assurance using traditional radiographic film dosimetric system and (3) to establish a more reliable, more efficient dosimetric verification system for intensity modulated radiation therapy. Methods: (1) The step wedge calibration technique was used to calibrate EBT radiochromic film and EDR2 radiographic film. The dose characteristics, the measurement consistency and the quality assurance process between the two methods were compared. (2) The in-phantom dose-measurement based verification technique has been adopted. Respectively, EBT film and EDR2 film were used to measure the same dose plane of IMRT treatment plans. The results of the dose map, dose profiles and iso- dose curves were compared with those calculated by CORVUS treatment planning system to evaluate the function of EBT film for dosimetric verification for intensity modulated radiation therapy. Results: (1) Over the external beam dosimetric range of 0-500 cGy, EBT/VXR-16 and EDR2/VXR-16 film dosimetric system had the same measurement consistency with the measurement variability less then 0.70%. The mean measurement variability of these two systems was 0.37% and 0.68%, respectively. The former proved to be the superior modality at measurement consistency, reliability, and efficiency over dynamic clinical dose range , furthermore, its quality assurance showed less process than the latter. (2) The dosimetric verification of IMRT plane measured with EBT film was quite similar to that with EDR2 film which was processed under strict quality control. In a plane of the phantom, the maximal dose deviation off axis between EBT film measurement and the TPS calculation was

  8. Comparison of dosimetric methods for virtual wedge analysis

    International Nuclear Information System (INIS)

    Bailey, M.; Nelson, V.; Collins, O.; West, M.; Holloway, L.; Rajapaske, S.; Arts, J.; Varas, J.; Cho, G.; Hill, R.

    2004-01-01

    Full text: The Siemens Virtual Wedge (Concord, USA) creates wedged beam profile by moving a single collimator jaw across the specified field size whilst varying the dose rate and jaw speed for use in the delivery of radiotherapy treatments. The measurement of the dosimetric characteristics of the Siemens Virtual Wedge poses significant challenges to medical physicists. This study investigates several different methods for measuring and analysing the virtual wedge for data collection for treatment planning systems and ongoing quality assurance. The beam profiles of the Virtual Wedge (VW) were compared using several different dosimetric methods. Open field profiles were measured with Kodak X-Omat V (Rochester, NY, USA) radiographic film and compared with measurements made using the Sun Nuclear Profiler with a Motorized Drive Assembly (MDA) (Melbourne, FL, USA) and the Scanditronix Wellhofer CC13 ionisation chamber and 24 ion Chamber Array (CA24) (Schwarzenbruck, Germany). The resolution of each dosimetric method for open field profiles was determined. The Virtual Wedge profiles were measured with radiographic film the Profiler and the Scanditronix Wellhofer CA 24 ion Chamber Array at 5 different depths. The ease of setup, time taken, analysis and accuracy of measurement were all evaluated to determine the method that would be both appropriate and practical for routine quality assurance of the Virtual Wedge. The open field profiles agreed within ±2% or 2mm for all dosimetric methods. The accuracy of the Profiler and CA24 are limited to half of the step size selected for each of these detectors. For the VW measurements a step size of 2mm was selected for the Profiler and the CA24. The VW profiles for all dosimetric methods agreed within ±2% or 2mm for the main wedged section of the profile. The toe and heel ends of the wedges showed the significant discrepancies dependent upon the dosimetry method used, up to 7% for the toe end with the CA24. The dosimetry of the

  9. 28 CFR 540.22 - Special postal services.

    Science.gov (United States)

    2010-07-01

    ... 540.22 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT...) In the event of loss or damage, any claim relative to this matter is made to the U.S. Postal Service... example, hobbycraft articles mailed out of the institution). Official mail is not insured. If such an item...

  10. 77 FR 20656 - Postal Service Classification and Price Adjustments

    Science.gov (United States)

    2012-04-05

    ... and Price Adjustments AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is... implement Picture Permit Imprint Indicia as price categories for First-Class Mail and Standard Mail letters and cards pursuant to 39 U.S.C. 3622 and 39 CFR 3010.\\1\\ The classification and price adjustment will...

  11. 78 FR 51678 - Market Tests of Experimental Postal Products

    Science.gov (United States)

    2013-08-21

    ... Gift Cards market test on April 28, 2011.\\11\\ The market test enabled customers to purchase a gift card... United States Postal Service for Temporary Extension of Gift Cards Market Test, June 18, 2013; Docket No... authorized the market test to proceed subject to the condition that the sale of gift cards be limited to...

  12. An Assessment of Customer Behaviours Regarding the Romanian Postal Services

    Directory of Open Access Journals (Sweden)

    Cristinel Constantin

    2015-09-01

    Full Text Available During the time the long distance communication has been one of the most important needs of the humanity. In the absence of telecommunication the postal services have been the main way of sending messages between people and other entities. Taking into account the importance of this market we assessed the nowadays coordinates of the Romanian postal market by conducting a research meant to identify the trends of postal services, the stage of competition and the customers’ behaviours regarding these services. The results show that the market is in developing process, with an increasing number of competitors but with a low number of significant competitors able to provide services on a large scale. In this context, the National Company Posta Romana remains the main market player but its positions are strongly threatened by private competitors especially on those market segments with high profitability. In order to defend its positions the national company has to put in practice proper marketing strategies focused mainly on the development of partnerships both with the senders and recipients of different postal deliveries, especially those ones with a higher attractiveness for the competitors.

  13. 77 FR 64148 - Postal Rate and Classification Changes

    Science.gov (United States)

    2012-10-18

    .... Priority Mail International. Overall, Priority Mail International (PMI) prices increase by 15.1 percent. The existing price structure of PMI Flat Rate, Retail, Commercial Base, and Commercial Plus price.... Additionally, the Postal Service may offer a promotional discount or rebate on certain PMI items. International...

  14. IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Atamtuerk, Alper; Hsu, I-Chow; Pouliot, Jean; Goldberg, Ken

    2011-01-01

    Purpose: Many planning methods for high dose rate (HDR) brachytherapy require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to develop a new approach for HDR brachytherapy by directly optimizing the dose distribution based on dosimetric criteria. Methods: The authors developed inverse planning by integer program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. They used their heuristic to compute dose plans for 20 anonymized prostate cancer image data sets from patients previously treated at their clinic database. Dosimetry was evaluated and compared to dosimetric criteria. Results: Dose plans computed from IPIP satisfied all given dosimetric criteria for the target and healthy tissue after a single iteration. The average target coverage was 95%. The average computation time for IPIP was 30.1 s on an Intel(R) Core TM 2 Duo CPU 1.67 GHz processor with 3 Gib RAM. Conclusions: IPIP is an HDR brachytherapy planning system that directly incorporates dosimetric criteria. The authors have demonstrated that IPIP has clinically acceptable performance for the prostate cases and dosimetric criteria used in this study, in both dosimetry and runtime. Further study is required to determine if IPIP performs well for a more general group of patients and dosimetric criteria, including other cancer sites such as GYN.

  15. Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.; Musijachenko, A.

    2004-01-01

    Development of the nation-wide network for monitoring and registration of individual doses is being in progress in Ukraine. The need for urgent action is caused by the fact, that despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralized dose accounting system in Ukraine, existing dosimetry services operate obsolete manual TLD readers and no methodological unity is observed by the dosimetry services. Presently the mixed dosimetric monitoring is practiced in Ukraine. Nuclear power plants and some major nuclear facilities have their own dosimetry services responsible for dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by territorial dosimetry laboratories affiliated to sanitary and epidemiology supervision bodies. In total these services cover about 38,000 occupationally exposed workers, including 5,500 in medicine, 16,400 employees of five nuclear power plants and about 16,000 workers dealing with other sources of occupational exposure (industry, research, military). It is prescribed by the governmental decree that three-level united state system assigned to covering all aspects of efficient dosimetric monitoring should be established. The tasks of the system, in particular, are: securing methodical unity of individual dosimetric monitoring; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programs; development and support of information infrastructure for logging, storage and access to data on individual dosimetric monitoring, in particular - keeping the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. In its development, the national system will be guided by international experience and will be established according to the best practices

  16. Dosimetric validation of planning system Eclipse 10 in partial breast irradiation treatments with IMRT; Validacion dosimetrica del sistema de planeacion Eclipse 10 en tratamientos de irradiacion parcial de mama con IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez T, J. J.; Gutierrez M, J. G.; Ortiz A, C. S.; Chagoya G, A.; Gutierrez C, J. G., E-mail: jvelaesfm@gmail.com [Centro Medico Nacional Siglo XXI, Hospital de Oncologia, Departamentos de Fisica Medica y Radioterapia, Av. Cuauhtemoc 330, 03020 Mexico D. F. (Mexico)

    2015-10-15

    Partial breast irradiation is a new type of external radiation therapy to treat breast cancer in early clinical stages. Consist of administering to the channel surgical high doses of radiation in few treatment sessions. In this paper the dose calculations of the planning system Eclipse version 10 for a treatment of partial breast irradiation with X-rays beams (6 MV) intensity modulated were compared against the measurements made with OSL dosimeters and radio-chromic dye film. An anthropomorphic mannequin was used in which OSL dosimeters were collocated near the surface, an inside the radio-chromic dye film one plate; with this latest one dimensional dose distribution was measured. Previously dosimeters were calibrated irradiating them with a beam of X-rays 6 MV under the conditions specified in the IAEA-398 protocol. The OSL dosimeters were read in the Micro star Landauer equipment, the radio-chromic dye films were read with a scanner Epson 10000-Xl and analyzed with FilmCal and PTW Verisoft programs. The differences between measured and calculated dose were as follows: 3.6±1% for the OSL dosimeter and 96.3±1% of the analyzed points approved the gamma index criterion (3%, 3m m) when comparing the matrices of calculated dose and measured with the radio-chromic dye film. These results confirm the good dosimetric performance of planning system used under specific conditions used in the partial breast irradiation technique. (Author)

  17. Liberalisation versus national protectionism: the European liberalised postal market: finalisation by whom?

    NARCIS (Netherlands)

    Versteegh, L.

    2010-01-01

    The new European Postal Directive of 2008 provides the postal market with new opportunities as it allows for the gradual development of competition of services of general interests in Europe. However, the directive leaves room for uncertainties and the full opening of the postal market is hampered

  18. Implementation of a dosimetric system based on detectors of to AL{sub 2}O{sub 3}:C and its use in radiation therapy; Implementacion de un sistema dosimetrico basdo en detectores de Al{sub 2}O{sub 3}: C y su uso en radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Marquez, P. J. F.; Guzman, C. C. S.; Pico, C. C.; Aymar, A. J. A.

    2013-07-01

    In this work is proposed to implement an alternative dosimetric system, based on OSL technology of crystals of oxide doped aluminum with carbon, to the AL{sub 2}O{sub 3}:C which do not possess the drawbacks of traditional detectors and possess the advantage for re-reading processes, allowing the storage of the detector as a record of delivered adsorbed dose which may be retested if required. (Author)

  19. Dosimetric improvements following 3D planning of tangential breast irradiation

    International Nuclear Information System (INIS)

    Aref, Amr; Thornton, Dale; Youssef, Emad; He, Tony; Tekyi-Mensah, Samuel; Denton, Lori; Ezzell, Gary

    2000-01-01

    Purpose: To evaluate the dosimetric difference between a simple radiation therapy plan utilizing a single contour and a more complex three-dimensional (3D) plan utilizing multiple contours, lung inhomogeneity correction, and dose-based compensators. Methods and Materials: This is a study of the radiation therapy (RT) plans of 85 patients with early breast cancer. All patients were considered for breast-conserving management and treated by conventional tangential fields technique. Two plans were generated for each patient. The first RT plan was based on a single contour taken at the central axis and utilized two wedges. The second RT plan was generated by using the 3D planning system to design dose-based compensators after lung inhomogeneity correction had been made. The endpoints of the study were the comparison between the volumes receiving greater than 105% and greater than 110% of the reference dose, as well as the magnitude of the treated volume maximum dose. Dosimetric improvement was defined to be of significant value if the volume receiving > 105% of one plan was reduced by at least 50% with the absolute difference between the volumes being 5% or greater. The dosimetric improvements in 49 3D plans (58%) were considered of significant value. Patients' field separation and breast size did not predict the magnitude of improvement in dosimetry. Conclusion: Dose-based compensator plans significantly reduced the volumes receiving > 105%, >110%, and volume maximum dose.

  20. Effective atomic numbers and electron density of dosimetric material

    Directory of Open Access Journals (Sweden)

    Kaginelli S

    2009-01-01

    Full Text Available A novel method for determination of mass attenuation coefficient of x-rays employing NaI (Tl detector system and radioactive sources is described.in this paper. A rigid geometry arrangement and gating of the spectrometer at FWHM position and selection of absorber foils are all done following detailed investigation, to minimize the effect of small angle scattering and multiple scattering on the mass attenuation coefficient, m/r, value. Firstly, for standardization purposes the mass attenuation coefficients of elemental foils such as Aluminum, Copper, Molybdenum, Tantalum and Lead are measured and then, this method is utilized for dosimetric interested material (sulfates. The experimental mass attenuation coefficient values are compared with the theoretical values to find good agreement between the theory and experiment within one to two per cent. The effective atomic numbers of the biological substitute material are calculated by sum rule and from the graph. The electron density of dosimetric material is calculated using the effective atomic number. The study has discussed in detail the attenuation coefficient, effective atomic number and electron density of dosimetric material/biological substitutes.

  1. Dosimetric studies in diagnostic radiology

    International Nuclear Information System (INIS)

    Mohamadain, K. E. M.

    2004-04-01

    A dosimetric study in pediatric radiology and adult patients was currently being carried out at the pediatrics units of two large hospitals in Rio de Janeiro city: IPPMG (Instituto de Pediatric e Puericultura Martagao Gesteira, University hospital of federal University of Rio de Janeiro), IFF (Instituto Fernandes Figueira, FIOCRUZ) and Hospital Geral de Bonsucesso, a large public hospital in Rio de Janeiro city (HGB) Brazil. The dosimetric study was also performed at three pediatrics units in Sudan, namely, Ahmed Gasim, Khartoum and Omdurman hospitals. For chest x-ray examination the entrance skin dose(ESD) for AP, PA and LAT projections of pediatric patients, and the scattered dose at the thyroid, ovary and gonads have been obtained with thermoluminescent dosimeters (TLD) and with use of a software package Dosecal in thr Brazilian hospitals, and with the software dosecal in the Sudanese hospitals.The aim of this work was to estimate the entrance skin dose (ESD), the effective dose (ED) and the body organ dose (BOD) for chest x-ray exposure in pediatric patients, and different exams for adults patients, and to compare the results obtained in the tow Countries Sudan and Brazil with the reference dose level. For ESD evaluation of the chest x-ray, three different TL dosimeters have been used, namely LiF: Mg, Ti (TLD 100) CaSo 4 : Dy and LiF:Mg, Cu,P (TLD 100 H). The age intervals considered were: 0-1 years, 1-5 years, 5-10 years and 10-15 years. The results obtained with all dosimeters were in good agreement with, those obtained by the dosecal software, especially for AP and PA projection. However, some discrepancies were found for the LAT projection. The results within Brazil were some what consistent while in Sudan, large difference were observed, it was also noted that the doses in Brazil hospitals were less than the reference dose levels while in Sudanese hospitals the doses were higher than the reference dose levels. For adult patients only the software dosecal

  2. Acurácia de informações sobre classes de medicamentos obtidas com questionário postal aplicado a idosos - Rio de Janeiro, RJ Accuracy of drug class information obtained from a postal questionnaire to elderly respondents

    Directory of Open Access Journals (Sweden)

    Maria Estrella L. Vasconcelos

    2009-12-01

    Brasileiros, using two approaches (postal and home visit to collect information from retirees who were 60 years old or older and beneficiaries of Brazil's national social security system (INSS. Statistics used were: simple kappa (k, adjusted kappa (PABAK, weighted kappa, intraclass correlation coefficients, indicators of sensitivity and specificity, and Luiz et al's graph method. RESULTS: 234 elderly (male = 42%; female = 58%; mean = 71.7 years answered both approaches. Concordance between the postal and face-to-face interview approaches was excellent (k=0.94 for hypoglycemics; very good (k = 0.83-0.82 for angiotensin-converting enzyme inhibitors and anti-hypertensives; good (k = 0.71 for diuretics; and reasonable (k = 0.47 for non-steroidal anti-inflammatories. Concordance was good (k = 0.61 for information on the total number of medications used. The validity of the postal approach was high, at times total, for the drugs used in treating diabetes (sensitivity and specificity = 100%, followed by anti-hypertensives. The lowest values obtained were for non-steroidal anti-inflammatories (sensitivity = 64%; specificity = 88%. CONCLUSION: the postal approach can be used to obtain accurate information on classes of medications used by a population aged 60 years or more with a social profile similar to that of social security beneficiaries.

  3. Dosimetric approaches: pregnancy and lactation

    International Nuclear Information System (INIS)

    Rojo, Ana M.

    2001-01-01

    The female nuclear medicine patient is of special concern to the evaluation of radiation dose since radiation protection point of view: a)- The females overall body size and organ sizes are generally smaller than those of her male counterpart (thus her radiation doses will be higher, given the same amounts of administered activity and similar biokinetics), the effective doses could be 25 per cent higher than a man; b)- Female gonads are inside the body instead of outside and are near several organs often important as source organs in internal dosimetry; female gonads doses could be up to 10 or 30 higher than male gonads (usually 3 order); c)- Risk of breast cancer is significantly higher among females than males; d)- During the pregnancy due to placental transfer of radiopharmaceuticals or radiation exposure from the urinary bladder the embryo/fetus could receive doses that must be avoid; e)- In the case of nursing infant is of special concern in such an analysis to determine the interruption period to avoid doses in the nursing infant. The dosimetric approaches to take account to assess internal doses in the pregnant woman and during the breast feeding are discussed. (author)

  4. 75 FR 880 - New Postal Product

    Science.gov (United States)

    2010-01-06

    ...: January 6, 2010. ADDRESSES: Submit comments electronically via the Commission's Filing Online system at... financial documentation is included with this filing as a separate Excel file. Id. at 2. \\4\\ The contract at... contract, the present contract ``allows the customer to tender items that meet the requirements for Canada...

  5. A GIS Application to Explore Postal Retail Outlet Locations

    Directory of Open Access Journals (Sweden)

    Nikola Trubint

    2012-03-01

    Full Text Available The use of GIS in solving a wide variety of problems in postal operations is expanding. This approach provides the development and usage of new methods in spatial data analysis, as support in achieving a better quality of the decision-making process. The use of location analysis model based on GIS software is implemented in solving the Belgrade postal retail outlet problem. One of the most important experiences of model implementation is that the local environmental conditions have a significant impact on strategic as well as operational approach. A portion of the material included in the paper has resulted from the Serbian PTT and CPC (Canada Post Corporation joint project Location Analysis.

  6. Sun safety knowledge and practice in UK postal delivery workers.

    Science.gov (United States)

    Houdmont, J; Davis, S; Griffiths, A

    2016-06-01

    Postal delivery workers spend a large proportion of their work time outdoors, placing them at increased risk of skin cancer. To date, no studies have examined occupational sun safety knowledge and practice within this group in the UK. To describe the occupational sun safety knowledge and practice of UK postal delivery workers and to investigate the association of demographic, personal and occupational factors with knowledge and practice in order to identify potential strategies for improving sun safety in this occupational group. Postal delivery workers completed a questionnaire that collected data on occupational sun safety knowledge and practice in addition to demographic, personal and workplace characteristics. One-way analysis of variances were applied to assess differences in knowledge and practice by these characteristics. A total of 1153 postal delivery workers completed the questionnaire, a 60% response rate. Thirty-three per cent reported receiving sun safety training within the previous 12 months. The majority of respondents reported correct knowledge on three of the six domains and good practice on four of the six behavioural domains. However, only one-fifth of respondents reported wearing sunglasses and ensuring a plentiful intake of water. Knowledge and practice differed significantly according to demographic, personal and workplace characteristics. There is a need to raise the profile of occupational skin cancer in this occupational group and to increase the priority given to occupational sun safety policies alongside targeted and tailored interventions, the effect of which can be evaluated. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine.

  7. Efficient postal service and respectful with the environment

    Energy Technology Data Exchange (ETDEWEB)

    Vera Lopez, J.A.

    2016-07-01

    The postal service is suffering an adaptation to the new markets opened by the users. The traditional post, letters and postcards, is being used less and is substituted by mail and packaging. To adequate to this new market it's important for the postal sector companies. In Spain, the operator of the Universal Postal Service has taken example from other companies of the sector, national and international, implanting electrical bicycle mail and packaging service in the centre of big cities. This is due to the fact that there are more the cities that are forbidding vehicle access to it's historical centres and the volume of packaging to deliver is greater. But, is it viable to deliver using hybrid and electrical vehicles in cities? This study intends to improve the distribution in cities with the implantation of these vehicles. It takes into account the characteristics of populations between 50.000 and 100.000 inhabitants, in which it will be analysed the advantages and inconvenience, doing special emphasis in the economic cost, conducting studies of the costs of implantation and amortization time. (Author)

  8. A randomized trial found online questionnaires supplemented by postal reminders generated a cost-effective and generalizable sample but don't forget the reminders.

    Science.gov (United States)

    Loban, Amanda; Mandefield, Laura; Hind, Daniel; Bradburn, Mike

    2017-12-01

    The objective of this study was to compare the response rates, data completeness, and representativeness of survey data produced by online and postal surveys. A randomized trial nested within a cohort study in Yorkshire, United Kingdom. Participants were randomized to receive either an electronic (online) survey questionnaire with paper reminder (N = 2,982) or paper questionnaire with electronic reminder (N = 2,855). Response rates were similar for electronic contact and postal contacts (50.9% vs. 49.7%, difference = 1.2%, 95% confidence interval: -1.3% to 3.8%). The characteristics of those responding to the two groups were similar. Participants nevertheless demonstrated an overwhelming preference for postal questionnaires, with the majority responding by post in both groups. Online survey questionnaire systems need to be supplemented with a postal reminder to achieve acceptable uptake, but doing so provides a similar response rate and case mix when compared to postal questionnaires alone. For large surveys, online survey systems may be cost saving. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. 75 FR 52378 - International Product Change-United States Postal Service Inbound Market-Dominant Multi-Service...

    Science.gov (United States)

    2010-08-25

    ... POSTAL SERVICE International Product Change--United States Postal Service Inbound Market-Dominant... Inbound Market-Dominant Multi- Service Agreements to the Market-Dominant Products List pursuant to 39 U.S... the Postal Regulatory Commission to Add Market-Dominant Multi-Service Agreements with Foreign Postal...

  10. Organ motion study and dosimetric impact of respiratory gating radiotherapy for esophageal cancer

    International Nuclear Information System (INIS)

    Lorchel, F.

    2007-04-01

    Chemoradiotherapy is now the standard treatment for locally advanced or inoperable esophageal carcinoma. In this indication, conformal radiotherapy is generally used. However, prognosis remains poor for these patients. Respiratory gating radiotherapy can decrease healthy tissues irradiation and allows escalation dose in lung, liver and breast cancer. In order to improve radiotherapy technique, we propose to study the feasibility of respiratory gating for esophageal cancer. We will study the respiratory motions of esophageal cancer to optimize target volume delineation, especially the internal margin (I.M.). We will test the correlation between tumour and chest wall displacements to prove that esophageal cancer motions are induced by respiration. This is essential before using free breathing respiratory gating systems. We will work out the dosimetric impact of respiratory gating using various dosimetric analysis parameters. We will compare dosimetric plans at end expiration, end inspiration and deep inspiration with dosimetric plan in free-breathing condition. This will allow us to establish the best respiratory phase to irradiate for each gating system. This dosimetric study will be completed with linear quadratic equivalent uniform dose (E.U.D.) calculation for each volume of interest. Previously, we will do a theoretical study of histogram dose volume gradation to point up its use. (author)

  11. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  12. Development of a dosimetric system for dental X-ray equipment quality control; Desenvolvimento de um sistema dosimetrico para controle de qualidade de equipamentos de raios-X odontologicos

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  13. Internal dosimetric evaluation due to uranium aerosols

    International Nuclear Information System (INIS)

    Garcia Aguilar Juan; Delgado Avila Gustavo

    1991-01-01

    The present work has like object to carry out the internal dosimetric evaluation to the occupationally exposed personnel, due to the inhalation of aerosols of natural uranium and enriched in the pilot plant of nuclear fuel production of the National Institute of Nuclear Research

  14. ESR dosimetric properties of some biomineral materials

    International Nuclear Information System (INIS)

    Hassan, Gamal M.; Sharaf, M.A.

    2005-01-01

    Dosimetric properties of g-irradiated modern coral and bioactive glass (Bio-G) samples analyzed with electron spin resonance (ESR) have been separately reported (Hassan et al., 2004; Sharaf and Hassan, 2004) and compared with alanine. These are combined here to allow a three-way comparison between these materials

  15. ESR dosimetric properties of some biomineral materials

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Gamal M. [Department of Ionizing Radiation Metrology, National Institute for Standards (NIS), Tersa Street, El-Haram, El-Giza, P.O. Box 136 Giza, El-Giza (Egypt)]. E-mail: gamalhassan65@hotmail.com; Sharaf, M.A. [Department of Ionizing Radiation Metrology, National Institute for Standards (NIS), Tersa Street, El-Haram, El-Giza, P.O. Box 136 Giza, El-Giza (Egypt)

    2005-02-01

    Dosimetric properties of g-irradiated modern coral and bioactive glass (Bio-G) samples analyzed with electron spin resonance (ESR) have been separately reported (Hassan et al., 2004; Sharaf and Hassan, 2004) and compared with alanine. These are combined here to allow a three-way comparison between these materials.

  16. Transport and dosimetric solutions for the ELIMED laser-driven beam line

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Romano, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Scuderi, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Amato, A. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Candiano, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Cuttone, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Giove, D. [INFN Sezione di Milano, Via Celoria 16, Milano (Italy); Korn, G.; Krasa, J. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Leanza, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Manna, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Maggiore, M. [INFN-LNL, Viale dell' Universitá 2 - 35020 Legnaro (PD) (Italy); Marchese, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Margarone, D. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Milluzzo, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Petringa, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Sabini, M.G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Azienda Ospedaliera Cannizzaro, Via Messina 829 - 95100 Catania (Italy); Schillaci, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); and others

    2015-10-01

    Within 2017, the ELIMED (ELI-Beamlines MEDical applications) transport beam-line and dosimetric systems for laser-generated beams will be installed at the ELI-Beamlines facility in Prague (CZ), inside the ELIMAIA (ELI Multidisciplinary Applications of laser–Ion Acceleration) interaction room. The beam-line will be composed of two sections: one in vacuum, devoted to the collecting, focusing and energy selection of the primary beam and the second in air, where the ELIMED beam-line dosimetric devices will be located. This paper briefly describes the transport solutions that will be adopted together with the main dosimetric approaches. In particular, the description of an innovative Faraday Cup detector with its preliminary experimental tests will be reported.

  17. La memoria de Vejer en sus primeras tarjetas postales

    OpenAIRE

    Gámiz-Gordo, Antonio

    2013-01-01

    Se acaba de imprimir este libro sobre imágenes del pasado del gaditano pueblo de Vejer de la Frontera, donde el profesor Gámiz reúne un novedoso plano de la ciudad de 1907 y 40 tarjetas postales fechadas entre 1904 y 1930 (muchas de ellas con puntos de toma localizables en el plano citado, al ser callejero de la época), además de comentarios y reflexiones que el autor realiza sobre las imágenes gráficas, contexto e historia. Así, se abordan temas como memoria e imagen, sus relaciones e int...

  18. Dosimetric monitoring in Ukraine - present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2005-01-01

    Full text: Ukraine is the country which utilizes radiation in many peaceful areas. So, nuclear energy sector includes 15 power units (including two new units commissioned in 2004), nuclear fuel cycle also include uranium mines, radiation sources are widely used in industry, science and medicine. As a result, about 50,000 occupationally exposed workers require dosimetric monitoring. However, presently dosimetry services in Ukraine cover only about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca. 12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services, responsible for dosimetric monitoring in industry and medicine operate in 13 of 25 oblasts (regions) of Ukraine. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38 % to 100 % depending on the oblast. With rare exception, instrumentation is represented by outdated manual TLD systems (inaccurate and insufficiently sensitive) capable of measurement of deep photon dose only; no personal monitoring of beta and neutron exposure is possible now. Quality assurance is limited to the annual metrological attestation of the dosimetric instruments. No information exchange infrastructure and dosimetric registry are in place. The dosimetric data is stored in home-made data environments or even in paper log-books, no data on individual doses is conveyed to central depository, which could be easily accessible for regulating authorities. Although the standing law requires elaboration of the United System for monitoring and registration individual doses, little was done so far, mainly due to lack of domestic funding. However, intention is strong to build such network in accordance with the best practice, covering not only the aspects of physical measurement and data storage, but also quality assurance, accreditation programs and training of the local personnel

  19. Dosimetric and thermoluminescent characteristics of sintered samples based on Li{sub 2}OAl{sub 2}O{sub 3}nSiO{sub 2} systems

    Energy Technology Data Exchange (ETDEWEB)

    Cogollo P, R.; Salcedo Q, J. [Universidad de Cordoba, Materials and Applied Physics Group, Carrera 6 No. 76-103, Monteria, Cordoba (Colombia); Gutierrez F, O., E-mail: rafaelcogollo@correo.unicordoba.edu.co [Metropolitan Technological Institute, Alquimia Group, Calle 54 No. 30-01, Medellin (Colombia)

    2013-10-01

    This work describes the thermoluminescent (Tl) characteristics of lithium aluminosilicates, Li{sub 2}OAl{sub 2}O{sub 3}nSiO{sub 2}, for its possible use as Tl dosimeter for low doses. The sinterized tablets of Li{sub 2}OAl{sub 2}O{sub 3}nSiO{sub 2} were characterized by means of X-ray diffraction (XRD), and irradiated at different doses using a Theratron 780 C-{sup 60}Co unit in air at room temperature. The Rasheedy's technique was used for the kinetic trap parameters determination. The XRD results show a mixture of two phases of 64% {beta}-spodumene and 36% {beta}-eucryptite in the sinterized tablets. Tl analysis indicates that in these systems, recombination processes prevail, and that these systems can be used successfully as Tl dosimeters for therapeutic dose ranges. (Author)

  20. Application of EPC Standards and Mobile Networks Services to Enhance the Quality of Postal Service

    Directory of Open Access Journals (Sweden)

    Vaculik Juraj

    2015-02-01

    Full Text Available This article deals with new technologies and methods to optimize the transport and delivery of postal mails. Introduction of this article defines the technologies and procedures that postal operators have started to use. The main part of the article describes specific implemented solutions of several postal operators and their benefits. The last part shows using of EPC standards in a processes chain. The conclusion of the article is devoted to the evaluation of these technologies and their potential in the area of postal sector.

  1. SU-C-201-02: Dosimetric Verification of SBRT with FFF-VMAT Using a 3-D Radiochromic/Optical-CT Dosimetry System

    Energy Technology Data Exchange (ETDEWEB)

    Na, Y; Black, P; Wuu, C [Columbia University, New York, NY (United States); Adamovics, J [Department of Chemistry and Biology, Rider University, Skillman, NJ (United States)

    2016-06-15

    Purpose: With an increasing use of small field size and high dose rate irradiation in the advances of radiotherapy techniques, such as stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS), an in-depth quality assurance (QA) system is required. The purpose of this study is to investigate a high resolution optical CT-based 3D radiochromic dosimetry system for SBRT with intensity modulated radiotherapy (IMRT) and flattening filter free (FFF) volumetric modulated arc therapy (VMAT). Methods: Cylindrical PRESAGE radiochromic dosimeters of 10cm height and 11cm diameter were used to validate SBRT. Four external landmarks were placed on the surface of each dosimeter to define the isocenter of target. SBRT plans were delivered using a Varian TrueBeam™ linear accelerator (LINAC). Three validation plans, SBRT with IMRT (6MV 600MU/min), FFF-VMAT (10MV 2400MU/min), and mixed FFF-VMAT (6MV 1400MU/min, 10MV 2400MU/min), were delivered to the PRESAGE dosimeters. Each irradiated PRESAGE dosimeter was scanned using a single laser beam optical CT scanner and reconstructed with a 1mm × 1mm high spatial resolution. The comparison of measured dose distributions of irradiated PRESAGE dosimeters to those calculated by Pinnacle{sup 3} treatment planning system (TPS) were performed with a 10% dose threshold, 3% dose difference (DD), and 3mm distance-to-agreement (DTA) Gamma criteria. Results: The average pass rates for the gamma comparisons between PRESAGE and Pinnacle{sup 3} in the transverse, sagittal, coronal planes were 94.6%, 95.9%, and 96.4% for SBRT with IMRT, FFF-VMAT, and mixed FFF-VMAT plans, respectively. A good agreement of the isodose distributions of those comparisons were shown at the isodose lines 50%, 70%, 80%, 90% and 98%. Conclusion: This study demonstrates the feasibility of the high resolution optical CT-based 3D radiochromic dosimetry system for validation of SBRT with IMRT and FFF-VMAT. This dosimetry system offers higher precision QA with 3D

  2. Quantitative analysis of patient-specific dosimetric IMRT verification

    International Nuclear Information System (INIS)

    Budgell, G J; Perrin, B A; Mott, J H L; Fairfoul, J; Mackay, R I

    2005-01-01

    Patient-specific dosimetric verification methods for IMRT treatments are variable, time-consuming and frequently qualitative, preventing evidence-based reduction in the amount of verification performed. This paper addresses some of these issues by applying a quantitative analysis parameter to the dosimetric verification procedure. Film measurements in different planes were acquired for a series of ten IMRT prostate patients, analysed using the quantitative parameter, and compared to determine the most suitable verification plane. Film and ion chamber verification results for 61 patients were analysed to determine long-term accuracy, reproducibility and stability of the planning and delivery system. The reproducibility of the measurement and analysis system was also studied. The results show that verification results are strongly dependent on the plane chosen, with the coronal plane particularly insensitive to delivery error. Unexpectedly, no correlation could be found between the levels of error in different verification planes. Longer term verification results showed consistent patterns which suggest that the amount of patient-specific verification can be safely reduced, provided proper caution is exercised: an evidence-based model for such reduction is proposed. It is concluded that dose/distance to agreement (e.g., 3%/3 mm) should be used as a criterion of acceptability. Quantitative parameters calculated for a given criterion of acceptability should be adopted in conjunction with displays that show where discrepancies occur. Planning and delivery systems which cannot meet the required standards of accuracy, reproducibility and stability to reduce verification will not be accepted by the radiotherapy community

  3. Dosimetric verification of the intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Zou Huawei; Jia Mingxuan; Wu Rong; Xiao Fuda; Dong Xiaoqi

    2004-01-01

    Objective: To discuss the methods of the dosimetric verification in the intensity-modulated radiation therapy (IMRT) and insure correct execution of the IMRT planning in the clinical practice. Methods: The CMSFOCUS9200 inverse planning system was used to provide optimized 5-field IMRT treatment plans for the patients. A phantom was made from true water-equivalent material. The doses of the interesting points and isodose distributions of the interesting planes in the phantom were calculated using patients' treatment plan. The phantom was placed on the couch of the accelerator and was irradiated using the phantom's treatment planning data. The doses of interesting points were measured using a 0.23 cc chamber and the isodose distributions of interesting planes were measured using RIT 113 film dosimetry system in the phantom. The results were compared with those from calculation in planning system for verification. Results: The doses and isodose distributions measured by the chamber and the film were consistent with those predicted by the planning. The error between the measured dose and calculated dose in the interesting points was less than 3%. Conclusion: The dosimetric verification of IMRT is a reliable measure in the course of its implementation. (authors)

  4. Application of summative content analysis to a postal questionnaire.

    Science.gov (United States)

    Griffiths, Thomas Howard

    2016-01-01

    Content analysis of replies to closed questions in questionnaires can be undertaken to understand remarks that may explain the responses, provide illustrative examples of issues raised in the questionnaire, define new issues or issues of importance that were not covered in the questionnaire and inform the design of new questions in future surveys. To discuss the usefulness of summative content analysis to free text in postal questionnaires. Content analysis provides useful comparative insights between two respondent groups in the case example provided. Five themes emerged: poor understanding of the concept of 'patient lateral transfer work technique' and the direct instrument nursing observation (DINO) instrument's key directions; outcomes of patient transfer; positive responses; manual handling risk; and poor translation into English of DINO. Respondents need an opportunity to clarify their responses to questionnaires using free text, to provide insight into their understanding of the question being asked, understanding of the concept or construct being discussed, and data triangulation through the confirmation of item responses and free-text comments. Responses to questions in a postal questionnaire and the opportunity for free-text commentary by respondents enable the identification of hidden meanings behind tickbox responses to questions.

  5. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation

    Science.gov (United States)

    Magro, G.; Molinelli, S.; Mairani, A.; Mirandola, A.; Panizza, D.; Russo, S.; Ferrari, A.; Valvo, F.; Fossati, P.; Ciocca, M.

    2015-09-01

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo® TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus® chamber. An EBT3® film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  6. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation

    International Nuclear Information System (INIS)

    Magro, G; Molinelli, S; Mairani, A; Mirandola, A; Panizza, D; Russo, S; Valvo, F; Fossati, P; Ciocca, M; Ferrari, A

    2015-01-01

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5–30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo ® TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus ® chamber. An EBT3 ® film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification. (paper)

  7. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation

    CERN Document Server

    Magro, G; Mairani, A; Mirandola, A; Panizza, D; Russo, S; Ferrari, A; Valvo, F; Fossati, P; Ciocca, M

    2015-01-01

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5–30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo® TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus® chamber. An EBT3® film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size r...

  8. African Postal Heritage : Tanzania 1885-1920s : part I : German East Africa, 1885-1914

    NARCIS (Netherlands)

    Dietz, A.J.

    2016-01-01

    An earlier version of this African Postal Heritage Paper was published as African Studies Centre Leiden Working Paper 119 / 2015: "A postal history of the First World War in Africa and its aftermath - German colonies; III Deutsch Ostafrika / German East Africa", written by Ton Dietz.

  9. 78 FR 22490 - Administrative Practice and Procedure; Postal Service; Review of Price Cap Rules

    Science.gov (United States)

    2013-04-16

    ...] Administrative Practice and Procedure; Postal Service; Review of Price Cap Rules AGENCY: Postal Regulatory Commission. ACTION: Proposed rule. SUMMARY: The Commission is initiating a review of its Price Cap Rules. The... implemented without a price cap calculation. Docket No. R2011-5, Order Approving Market Dominant Price...

  10. 29 CFR 4.122 - Contracts for operation of postal contract stations.

    Science.gov (United States)

    2010-07-01

    ... Application of the McNamara-O'Hara Service Contract Act Specific Exclusions § 4.122 Contracts for operation of postal contract stations. The Act, in paragraph (7) of section 7, exempts from its provisions “any... 29 Labor 1 2010-07-01 2010-07-01 true Contracts for operation of postal contract stations. 4.122...

  11. Conceptual foresight of the volumes of postal money orders in the Republic of Komi

    Directory of Open Access Journals (Sweden)

    Lyubov' Aleksandrovna Kuratova

    2012-03-01

    Full Text Available This paper describes a methodology elaborated for forecasting the volume of postal services on the basis of statistical methods of regression analysis on the example of the Republic of Komi. The influence of internal and external factors on the market of postal money orders of the Republic is constructed and investigated using the statistical regression model of the market of postal money orders of the Komi Republic in the period of 2005–2010. The conceptual foresight of development of the regional market of postal money orders for 2011–2012 is presented. Regression models were analyzed not only for the dynamic sequence of data, but also for sequences of data on territories, which revealed independent correlated factors which are weakly changing and evolving over time. The presented results have important practical and methodological significance for predicting both the volume of postal money orders as well as other types of services.

  12. FLUXUS E ARTE POSTAL COMO ARTE RELACIONAL: BREVE ESTUDO

    OpenAIRE

    Amizo, Isadora Banducci

    2014-01-01

    Este artigo tem como objetivo a análise das questões que envolvem a produção da Arte postal ou Mail art, e do grupo Fluxus, difundidas ao redor do mundo a partir da década de 1960. Procura-se investigar sua aproximação com o conceito de arte relacional, exposto pelo crítico e filósofo francês Nicolas Bourriaud no livro “Estética relacional”. Para isso, são revisadas algumas das temáticas que envolvem as duas expressões artísticas destacando–se a produção de alguns de seus principais expoentes...

  13. Postal TLD audits in radiotherapy in the Czech Republic: current status, experience and potential

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Kapucianova, Michaela; Dufek, Vladimir

    2014-01-01

    The paper deals with practice and performance of postal TLD audits in radiotherapy with emphasis on the possibilities of application of the advanced versions that were developed following up technological progress in radiotherapy. The new methodologies of the TLD audit are focused specifically on up-to-date linear accelerators, equipped with multileaf collimators, and modern treatment planning systems. The dose is checked by the TLD not only for reference conditions but also in conditions of radiation fields influenced by presence of inhomogeneities in the irradiated volume. As regards small radiation fields, the check also includes dose profile verification using gafchromic films. The methodologies were tested within pilot studies performed in collaboration with some Czech radiotherapy centers. The results and experience gave evidence of the usefulness and appropriateness of the new TLD audit methodologies. (orig.)

  14. POLLUTION PREVENTION OPPORTUNITY ASSESSMENT - U.S. POSTAL INSPECTION SERVICE FORENSIC & TECHNICAL SERVICES DIVISION - NATIONAL FORENSIC LABORATORY, DULLES, VIRGINIA

    Science.gov (United States)

    The United States Postal Service (USPS) in cooperation with EPA's National Risk Management Research Laboratory (NRMRL) is engaged in an effort to integrate waste prevention and recycling activities into the waste management programs at Postal facilities. This report describes the...

  15. Assessment of the potential implementation of the Fricke dosimetric system to measure the gamma dose rate in a mixed field at the Central Irradiation Facility of the Thermal Column at RA-3

    International Nuclear Information System (INIS)

    Curotto, P.; Pozzi, E.C.C.; Thorp, S.I.; Casal, M.

    2013-01-01

    Introduction: The characterization of the mixed field, i.e. neutron and gamma radiation, at the Central Irradiation Facility of the Thermal Column (FCCT) at RA-3 is pivotal to the radiobiology experiments carried out there. One of the greatest difficulties of gamma dosimetry in a mixed field such as the FCCT field is to discriminate the perturbation induced by the high neutron flux. Given that the neutron spectrum of the source is very well characterized, it is of interest to have an alternative way of measuring gamma dose rate to be able to compare the results with those currently derived from an ionization chamber (IC). The Fricke dosimetric system is widely used as an absolute dosimeter in pure, very high dose radiation fields. The experimental set-up of these dosimeters exhibits advantages compared to instrumentation with IC. The aim of the present study was to adapt the system to use it as a measuring method at FCCT and perform a comparative analysis. Materials and Methods: Once the technique to prepare the dosimeters was adapted at our laboratory the following irradiations were carried out: one in a pure, known, gamma field, and four in the mixed FCCT field in the same position, employing 3 different configurations to obtain different relations between the radiation components in the field. The following configurations were employed: a) with closed neutron shielding, b) with open neutron shielding and c) no shielding. The results were compared with those derived from measurements with the IC. Results: In pure gamma field experience the following results were obtained: the dose measured by the IC was (44.6 ± 0.5) Gy (in air) and Fricke dose was (48.2 ± 1.1) Gy. Comparing the configurations with closed and open neutron shielding, the IC signal rose by 4% (considered not significant) whereas the Fricke dose rate increased by 15%. Comparing the configurations with closed shielding and no shielding, the gamma dose rate measured with the Fricke system rose by 153

  16. Update of the Picker C9 irradiator control system of the gamma II room of the secondary laboratory of dosimetric calibration; Actualizacion del sistema de control del irradiador Picker C9 de la sala gamma II del laboratorio secundario de calibracion dosimetrica

    Energy Technology Data Exchange (ETDEWEB)

    Simon S, L. E.

    2016-07-01

    The Picker C9 irradiator is responsible for the calibration of different radiological equipment and the control system that maintains it in operation is designed in the graphical programming software LabVIEW (Laboratory Virtual Instrumentation Engineering Workbench), being its major advantages: the different types of communication, easy interconnection with other software and the recognition of different hardware devices, among others. Operation of the irradiator control system is performed with the NI-Usb-6008 (DAQ) data acquisition module of the National Instruments Company. The purpose of this work is to update the routines that make the Picker C9 control system of the gamma II room of the secondary laboratory of dosimetric calibration, using the graphic programming software LabVIEW, as well as to configure the new acquisition hardware of data that is implemented to control the Picker C9 irradiator system and ensure its operation. (Author)

  17. Dosimetric properties of the fast neutron therapy beams at TAMVEC

    International Nuclear Information System (INIS)

    Almond, P.R.; Smith, A.R.; Smathers, J.R.; Otte, V.A.

    1975-01-01

    In October 1972, M.D. Anderson Hospital and Tumor Institute of the University of Texas System Cancer Center initiated a clinical trial of fast neutron radiotherapy using the cyclotron at Texas A and M University. Initially, the study used neutrons produced by bombarding beryllium with 16 MeV deuterons, but since March, 1973, neutrons from 50 MeV deuterons have been used. The dosimetric properties of the 30 MeV beams have also been measured for comparison with the neutron beams from D-T generators. The three beams are compared in terms of dose rate, skin sparing, depth dose and field flatness. Isodose curves for treatment planning were generated using the decrement line method and compared to curves measured by a computer controlled isodose plotter. This system was also used to measure the isodose curves for wedge fields. Dosimetry checks on various patients were made using silicon diodes as in vivo fast neutron dosimeters

  18. A postal history of the First World War in Africa and its aftermath - German colonies : III Deutsch-Sdwestafrika (SWA)

    NARCIS (Netherlands)

    Dietz, A.J.

    2015-01-01

    The 'Great War' had a major impact on Africa and that is visible in the post stamps used in the various postal territories in Africa. This paper discusses the postal offices, postal services, and stamps used in the German colony Deutsch-Sdwestafrika (SWA) during the early twentieth century. For the

  19. Hot pixel generation in active pixel sensors: dosimetric and micro-dosimetric response

    Science.gov (United States)

    Scheick, Leif; Novak, Frank

    2003-01-01

    The dosimetric response of an active pixel sensor is analyzed. heavy ions are seen to damage the pixel in much the same way as gamma radiation. The probability of a hot pixel is seen to exhibit behavior that is not typical with other microdose effects.

  20. Propuesta de un sistema integral para una empresa de servicios postales

    OpenAIRE

    Ancajima Navarro, Julia Noemi; Ancajima Navarro, Julia Noemi; Ancajima Navarro, Julia Noemi

    2013-01-01

    El servicio postal es un sistema dedicado a transportar alrededor del mundo documentos escritos, así como paquetes de tamaño pequeño o mediano (encomiendas). Todo envió a través del sistema postal es llamado correo o correspondencia. Los paquetes y las cartas son "envíos postales" que se pueden transportar por tierra, mar o aire, cada uno con tarifas diferentes. Las cartas y documentos son inviolables hasta que son entregadas al destinatario. La aparición del ferrocarril entre 1840 y 18...

  1. Conceptual foresight of the volumes of postal money orders in the Republic of Komi

    OpenAIRE

    Lyubov Kuratova

    2012-01-01

    This paper describes a methodology elaborated for forecasting the volume of postal services on the basis of statistical methods of regression analysis on the example of the Republic of Komi. The influence of internal and external factors on the market of postal money orders of the Republic is constructed and investigated using the statistical regression model of the market of postal money orders of the Komi Republic in the period of 2005–2010. The conceptual foresight of development of the ...

  2. Information related to postal flows and big data analysis potential. The case of Spain

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Alvaro, O.; Nuñez Gonzalez, A.

    2016-07-01

    National Post Offices manage huge volumes of letters and parcels. Data associated to these flows are growing fast, with a great variety related to the diversity of postal products. The research described in this paper has classified all information flows of Correos, the Spanish National Post Office. In spite of the complexity of the current postal service portfolio, only four categories of matrices allow the classification of all postal information flows. Thanks to the migration towards new products, analyses with simple techniques will provide more and better information in the future, due to the structured nature of existing databases. (Author)

  3. Dosimetric adaptive IMRT driven by fiducial points

    International Nuclear Information System (INIS)

    Crijns, Wouter; Van Herck, Hans; Defraene, Gilles; Van den Bergh, Laura; Haustermans, Karin; Slagmolen, Pieter; Maes, Frederik; Van den Heuvel, Frank

    2014-01-01

    Purpose: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy have become standard treatments but are more sensitive to anatomical variations than 3D conformal techniques. To correct for inter- and intrafraction anatomical variations, fast and easy to implement methods are needed. Here, the authors propose a full dosimetric IMRT correction that finds a compromise in-between basic repositioning (the current clinical practice) and full replanning. It simplifies replanning by avoiding a recontouring step and a full dose calculation. It surpasses repositioning by updating the preoptimized fluence and monitor units (MU) using a limited number of fiducial points and a pretreatment (CB)CT. To adapt the fluence the fiducial points were projected in the beam's eye view (BEV). To adapt the MUs, point dose calculation towards the same fiducial points were performed. The proposed method is intrinsically fast and robust, and simple to understand for operators, because of the use of only four fiducial points and the beam data based point dose calculations. Methods: To perform our dosimetric adaptation, two fluence corrections in the BEV are combined with two MU correction steps along the beam's path. (1) A transformation of the fluence map such that it is realigned with the current target geometry. (2) A correction for an unintended scaling of the penumbra margin when the treatment beams scale to the current target size. (3) A correction for the target depth relative to the body contour and (4) a correction for the target distance to the source. The impact of the correction strategy and its individual components was evaluated by simulations on a virtual prostate phantom. This heterogeneous reference phantom was systematically subjected to population based prostate transformations to simulate interfraction variations. Additionally, a patient example illustrated the clinical practice. The correction strategy was evaluated using both dosimetric

  4. Dosimetric adaptive IMRT driven by fiducial points

    Energy Technology Data Exchange (ETDEWEB)

    Crijns, Wouter, E-mail: wouter.crijns@uzleuven.be [Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Herestraat 49, 3000 Leuven, Belgium and Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Van Herck, Hans [Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven, Belgium and Department of Electrical Engineering (ESAT) – PSI, Center for the Processing of Speech and Images, KU Leuven, 3000 Leuven (Belgium); Defraene, Gilles; Van den Bergh, Laura; Haustermans, Karin [Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Slagmolen, Pieter [Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Department of Electrical Engineering (ESAT) – PSI, Center for the Processing of Speech and Images, KU Leuven, 3000 Leuven (Belgium); iMinds-KU Leuven Medical IT Department, KU Leuven, 3000 Leuven (Belgium); Maes, Frederik [Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Department of Electrical Engineering (ESAT) – PSI, Center for the Processing of Speech and Images, KU Leuven and iMinds, 3000 Leuven (Belgium); Van den Heuvel, Frank [Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Herestraat 49, 3000 Leuven, Belgium and Department of Oncology, MRC-CR-UK Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford OX1 2JD (United Kingdom)

    2014-06-15

    Purpose: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy have become standard treatments but are more sensitive to anatomical variations than 3D conformal techniques. To correct for inter- and intrafraction anatomical variations, fast and easy to implement methods are needed. Here, the authors propose a full dosimetric IMRT correction that finds a compromise in-between basic repositioning (the current clinical practice) and full replanning. It simplifies replanning by avoiding a recontouring step and a full dose calculation. It surpasses repositioning by updating the preoptimized fluence and monitor units (MU) using a limited number of fiducial points and a pretreatment (CB)CT. To adapt the fluence the fiducial points were projected in the beam's eye view (BEV). To adapt the MUs, point dose calculation towards the same fiducial points were performed. The proposed method is intrinsically fast and robust, and simple to understand for operators, because of the use of only four fiducial points and the beam data based point dose calculations. Methods: To perform our dosimetric adaptation, two fluence corrections in the BEV are combined with two MU correction steps along the beam's path. (1) A transformation of the fluence map such that it is realigned with the current target geometry. (2) A correction for an unintended scaling of the penumbra margin when the treatment beams scale to the current target size. (3) A correction for the target depth relative to the body contour and (4) a correction for the target distance to the source. The impact of the correction strategy and its individual components was evaluated by simulations on a virtual prostate phantom. This heterogeneous reference phantom was systematically subjected to population based prostate transformations to simulate interfraction variations. Additionally, a patient example illustrated the clinical practice. The correction strategy was evaluated using both dosimetric

  5. Postoperative telegammatherapy of breast cancer (Dosimetric studies)

    Energy Technology Data Exchange (ETDEWEB)

    Todorov, J; Mitrov, G [Nauchno-Izsledovatelski Onkologichen Inst., Sofia (Bulgaria); Konstantinov, B; Dobrev, D [Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya

    1977-01-01

    The method employed for postoperative radiation therapy of breast cancer at the Radiologic Clinic of the Medical Academy in Sofia is described. Results are reported and discussed of dosimetric studies carried out with the T-100 on heterogeneous tissue-equivalent Rando phantom for dose distributions in the regional lymph basin and the underlying tissues and organs. The results show coincidence between calculated and measured doses in the regional lymph basin and the thoracic wall. It was demonstrated that maximal radiation loading (3600 to 5500 rad) occurs in the apical and the hilar lung area.

  6. Speciation and internal dosimetry: from chemical species to dosimetric models

    International Nuclear Information System (INIS)

    Paquet, F.; Frelon, S.; Cote, G.; Madic, C.

    2004-01-01

    Speciation studies refer to the distribution of species in a particular sample or matrix. These studies are necessary to improve the description, understanding and prediction of trace element kinetics and toxicity. In case of internal contamination with radionuclides, speciation studies could help to improve both the biokinetic and dosimetric models for radionuclides. There are different methods to approach the speciation of radionuclide in a biological system, depending on the degree of accuracy needed and the level of uncertainties accepted. Among them, computer modelling and experimental determination are complementary approaches. This paper describes what is known about speciation of actinides in blood, GI-tract, liver and skeleton and of their consequences in terms of internal dosimetry. The conclusion is that such studies provide very valuable data and should be targeted in the future on some specific tissues and biomolecules. (authors)

  7. Dosimetric analysis of radiation sources to use in dermatological lesions

    International Nuclear Information System (INIS)

    Tada, Ariane

    2010-01-01

    Skin lesions undergoing therapy with radiation sources may have different patterns of malignancy. Malignant lesions or cancer most commonly found in radiotherapy services are carcinomas. Radiation therapy in skin lesions is performed with low penetration beams and orthovoltage X-rays, electron beams and radioactive sources ( 192 Ir, 198 Au, e 90 Sr) arranged on a surface mold or in metal applicator. This study aims to analyze the therapeutic radiation dose profile produced by radiation sources used in skin lesions radiotherapy procedures. Experimental measurements for the analysis of dosimetric radiation sources were compared with calculations obtained from a computer system based on the Monte Carlo Method. Computational results had a good agreement with the experimental measurements. Experimental measurements and computational results by the MCNP4C code have been used to validate the calculations obtained by MCNP code and to provide a reliable medical application for each clinical case. (author)

  8. Dosimetric radiation measurements in space

    International Nuclear Information System (INIS)

    Benton, E.V.

    1983-01-01

    In reviewing radiation exposures recorded during spaceflights of the United States and the Soviet Union, this paper examines absorbed dose and dose rates as a function of parameters such as inclination, altitude, spacecraft type and shielding. Complete shielding from galactic cosmic rays does not appear practical because of spacecraft weight limitations. Preliminary data on neutron and HZE-particle components and LET spectra are available. Most of the data in this paper are from manned missions; for low Earth-orbit missions, the dose encountered is strongly altitude-dependent, with a weaker dependence on inclination. The doses range from about 6 millirad per day for the Space Transportation System (STS) No. 3 flight to about 90 mrad per day for Skylab. The effective quality factor (QF) for the near-Earth orbits and free space has been estimated to be about 1.5 and about 5.5 respectively. (author)

  9. Beam standardization and dosimetric methodology in computed tomography

    International Nuclear Information System (INIS)

    Maia, Ana Figueiredo

    2005-01-01

    Special ionization chambers, named pencil ionization chambers, are used in dosimetric procedures in computed tomography beams (CT). In this work, an extensive study about pencil ionization chambers was performed, as a contribution to the accuracy of the dosimetric procedures in CT beams. The international scientific community has recently been discussing the need of the establishment of a specific calibration procedure for CT ionization chambers, once these chambers present special characteristics that differentiate them from other ionization chambers used in diagnostic radiology beams. In this work, an adequate calibration procedure for pencil ionization chambers was established at the Calibration Laboratory, of the Institute de Pesquisas Energeticas e Nucleares, in accordance with the most recent international recommendations. Two calibration methodologies were tested and analyzed by comparative studies. Moreover, a new extended length parallel plate ionization chamber, with a transversal section very similar to pencil ionization chambers, was developed. The operational characteristics of this chamber were determined and the results obtained showed that its behaviour is adequate as a reference system in CT standard beams. Two other studies were performed during this work, both using CT ionization chambers. The first study was about the performance of a pencil ionization chamber in standard radiation beams of several types and energies, and the results showed that this chamber presents satisfactory behaviour in other radiation qualities as of diagnostic radiology, mammography and radiotherapy. In the second study, a tandem system for verification of hal'-value layer variations in CT equipment, using a pencil ionization chamber, was developed. Because of the X rays tube rotation, the determination of half-value layers in computed tomography equipment is not an easy task, and it is usually not performed within quality control programs. (author)

  10. Postal TLD audit in radiotherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Kapucianova, M.; Ekendah, D. l.; Bulanek, B.

    2014-01-01

    The postal TLD audit in radiotherapy is an independent check of dose applied by radiotherapy centers. Our poster provides basic information on the methodology of dose determination within the TLD audit. An overview of different versions of the TLD audit that are focused on specific techniques in radiotherapy is given. We also present results of so called basic version of the TLD audit that is performed regularly for purposes of the State Office for Nuclear Safety. Moreover, results of intercomparison measurements organized by the IAEA (International Atomic Energy Agency), in which our laboratory takes part every year, are shown.The methodology of dose determination is based on TL measurement of LiF:Mg,Ti powder. The TL dosemeter (TLD) has form of a plastic capsule containing approximately 160 mg of this material. Before the TL reading, the powder of each particular irradiated dosemeter is divided into 9 identical samples by means of an accurate dispenser. The dosemeter response is given as average of TL responses of the 9 samples. The dose absorbed in water is computed from the TLD response by application of calibration factor and correction coefficients for elimination of energy dependence, supra-linearity and fading of the TL material. The evaluation of the TLD audit is based on comparison of the dose measured by the TLD and the dose stated by a radiotherapy center. Relative deviation between these doses is calculated. Several versions of the TLD audit are available. (authors)

  11. A postal survey of maternal sleep in late pregnancy

    Directory of Open Access Journals (Sweden)

    Hutchison B Lynne

    2012-12-01

    Full Text Available Abstract Background Sleep disturbances in late pregnancy are common. This study aimed to survey sleep problems in third trimester pregnant women and to compare sleep in the pre-pregnancy period with the third trimester. Methods Third-trimester women (n=650 were sent a postal survey containing questions relating to sleep experience, including perceived sleep quality, sleep difficulties, night waking, sleep environment, snoring, daytime tiredness and daytime napping. Time periods reported on were before pregnancy and in the last week. Results Respondents numbered 244 (38%. Before pregnancy, the mean reported duration of night-time sleep was 8.1 (SD 1.1 hours; in the last week this had decreased to 7.5 (SD 1.8 hours (p10 prior to pregnancy, whereas in the last week 33% scored in the abnormal range. Likewise, 5% had regularly napped during the daytime before pregnancy, compared with 41% in the last week. Conclusions Sleep problems are common in women in late pregnancy, and increase markedly compared with before pregnancy.

  12. The IAEA/WHO TLD postal programme for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Izewska, J.; Andreo, P.

    2000-01-01

    Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO), has performed postal TLD audits to verify the calibration of radiotherapy beams in developing countries. A number of changes have recently been implemented to improve the efficiency of the IAEA/WHO TLD programme. The IAEA has increased the number of participants and reduced significantly the total turn-around time to provide results to the hospitals within the shortest possible time following the TLD irradiations. The IAEA has established a regular follow-up programme for hospitals with results outside acceptance limits of ±5%. The IAEA has, over 30 years, verified the calibration of more than 3300 clinical photon beams at approximately 1000 radiotherapy hospitals. Only 65% of those hospitals who receive TLDs for the first time have results within the acceptance limits, while more than 80% of the users that have benefited from a previous TLD audit are successful. The experience of the IAEA in TLD audits has been transferred to the national level. The IAEA offers a standardized TLD methodology, provides Guidelines and gives technical back-up to the national TLD networks. The unsatisfactory status of the dosimetry for radiotherapy, as noted in the past, is gradually improving however, the dosimetry practices in many hospitals in developing countries need to be revised in order to reach adequate conformity to hospitals that perform modern radiotherapy in Europe, USA and Australia. (author)

  13. A new postal quality assurance program for diagnostic radiology departments

    International Nuclear Information System (INIS)

    Brown, L.D.

    1988-01-01

    The Federal Government of Canada has responsibility for the design and performance of new x-ray equipment, but the Provinces have responsibility for controlling the installation, maintenance and use of the equipment. For the past 30 years Saskatchewan has had regular inspection of X-ray units by radiation health officers who have ensured that deficiencies are corrected. With the present emphasis on quality assurance procedures and hospital accreditation requirements some additional needs have had to be met. These are primarily due to unusual geographical factors. The province covers a quarter to a million square miles and has a continental climate with very severe winters. This used to impede winter travel and many small communities therefore established their own hospital. Today there are a large number of very small hospitals (four beds and upwards) which are geographically widely spread and which, with current resources, can only be visited rather infrequently. A mail out test package, primarily designed to give early warning of the existence of radiation related problems, has therefore been introduced. If a test gives an unexpected result, a prompt visit can be made to the centre concerned to carry out whatever more sophisticated test procedures may be necessary. Experience has shown however that the postal test package has, in itself, a high diagnostic potential so the source of the problem can often be identified without a visit becoming necessary

  14. ESR dosimetric properties of modern coral reef

    Energy Technology Data Exchange (ETDEWEB)

    Sharaf, M.A. E-mail: mokhtar_sharaf@yahoo.com; Hassan, Gamal M

    2004-06-01

    Modern coral reef samples from Egypt were irradiated with {sup 60}Co{gamma}-rays to study radicals for dosimetric materials with electron spin resonance (ESR). The ESR spectrum for the radical species in unirradiated coral is characterized by four signals with spectroscopic splitting factors of g=2.0056, 2.0030, 2.0006 and 1.997. The signal at g=2.0006{+-}0.0005 is ascribed to free rotation CO{sub 2}{sup -} radicals and used as a dosimetric one. The response to {gamma}-ray doses ranging from 5 to 10{sup 3} Gy and the thermal stability has been studied. The number of free radicals per 100 eV (G-value) was found to be 0.45 {+-} 0.1 and 0.9 {+-} 0.18 for coral and alanine, respectively. The lifetime of radicals and the activation energy were estimated from Arrhenius plots to be approximately 8 x 10{sup 5} {+-} 1.6 x 10{sup 5} years, and 1.12 eV, respectively.

  15. A Proven Method for Meeting Export Control Objectives in Postal and Shipping Sectors

    Science.gov (United States)

    2015-02-01

    A Proven Method for Meeting Export Control Objectives in Postal and Shipping Sectors Gregory Crabb, U.S. Postal Inspection Service Julia H...mail fraud, mail theft, identity theft, child exploitation, and prohibited mailings such as bombs and biological and chemical threats...April 2012. http://resources.sei.cmu.edu/library/asset-view.cfm?assetid=10085 [Allen 2014a] Allen, Julia H., Crabb, Gregory; Curtis, Pamela D

  16. IAEA/ WHO TLD postal dose intercomparison results in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Bhuiyan, N.U.; Rahman, S.

    2001-01-01

    Full text: For the accurate delivery of prescribed dose to the patients, high precision and accuracy in radiation dosimetry is required. The hospital/medical physicist is responsible for the accurate delivery of whole planned radiation doses to the patients prescribed by the radio therapist. The proper delivery of radiation doses depends upon the accurate output measurements of doses from the therapy machines. In Bangladesh, only six 60 Co units and five deep therapy machines are in use. Some more are expected to be installed soon. Still in 2001, none of the Government radiotherapy centers in Bangladesh was properly equipped with medical physicists as well as radiotherapy dosimetry equipment. Bangladesh Atomic Energy Commission (BAEC) is responsible for radiation safety in Bangladesh and BAEC has assigned Secondary Standard Dosimetry Laboratory (SSDL) of Bangladesh for providing dosimetry calibration to all radiotherapy centers in Bangladesh. The output measurements of therapy machines are performed once in a year by SSDL and the results are compared by participating in the annual TLD postal dose intercomparison program organized by IAEA/WHO SSDL Network. The absorbed dose to water is determined using IAEA dosimetry protocol (TRS 277 and 381) and water phantom of size 30 x 30 x 30 cm 3 , The measurements of SSDL are traceable to NPL of UK. The accuracy achieved in SSDL, Bangladesh has been found better than ± 3.5%, which is within the prescribed limit of dosimetry standard of IAEA. The methodology of output dose measurements in different radiotherapy centers in Bangladesh is described along with the IAEA/WHO intercomparison results

  17. PROGNOSYS AND ANALYSIS OF DOSIMETRIC SITUATION AFTER EMERGENCY ATMOSPHERIC RELEASE OF NPP IN UKRAINE

    Directory of Open Access Journals (Sweden)

    Iu. V. Bonchuk

    2009-01-01

    Full Text Available The system for the operative analysis of dosimetric situation after radiation emergencies at nuclear power plants in Ukraine (KADO is developed for decision making support. Emergency release in KADO is modelled as sequence of the discrete elements which are emitted after small time intervals that allows to take into account in calculations heterogeneity of distribution of pollution in a released cloud. Calculated predicted and avertable doses are the base information for justification of emergency and urgent countermeasures.

  18. Applications of sensitivity function to dosimetric data adjustments

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu

    1984-01-01

    Sensitivity functions are applied to the dosimetric field in the spectrum unfolding technique, also called as the data adjustment technique which are statistical estimation procedures of the neutron spectrum or relating dosimetric quantities basing on the reaction-rate data measurements. Using the practical formulae and numerical examples of the sensitivity functions in the dosimetric data adjustments, two comments are made that (1) present sensitivity values are highly depending on the initial spectrum inputs and (2) more attention should be paid to the dependency of the sensitivity on the very uncertain covariance data inputs of the initial neutron spectrum. (author)

  19. Dosimetric evaluation program for dental radiology practices

    International Nuclear Information System (INIS)

    Gregori, B.; Milat, J.; Fernandez, J.; Micinquevich, S.; Andrieu, J.

    1992-01-01

    The preliminary results of a program undertaken to estimate the doses to patients associated with dental radiology practices in Argentine, are presented. Information collected from the search demonstrated that the Dieck and coronal techniques are the most commonly used practices, while all the examinations are performed by using a circular collimator. For both practices, the dosimetric studies were carried out on a Rando Alderson phantom. All dose measurements were made using thermoluminescent detectors LiF and Ca 2 F. In addition, a mathematical model was developed by applying the Monte Carlo method to a MIRD-V phantom. Circular and rectangular collimators were used. Absorbed dose distribution on head and neck, as well as surface dose distribution, were estimated. The comparison of the performance of both collimators shows that the use of the rectangular one allows for a dose reduction of 80%. Besides, a good correlation between the physical and mathematical models applied was found. (author)

  20. Dosimetric management during a criticality accident

    International Nuclear Information System (INIS)

    Lebaron-Jacobs, L.; Fottorino, R.; Racine, Y.; Miele, A.; Barbry, F.; Briot, F.; Distinguin, S.; Le Goff, J.P.; Berard, P.; Boisson, P.; Cavadore, D.; Lecoix, G.; Persico, M.H.; Rongier, E.; Challeton-De Vathaire, C.; Medioni, R.; Voisin, P.; Exmelin, L.; Flury-Herard, A.; Gaillard-Lecanu, E.; Lemaire, G.; Gonin, M.; Riasse, C.

    2008-01-01

    A working group from health occupational and clinical biochemistry services on French sites has issued essential data sheets on the guidelines to follow in managing the victims of a criticality accident. Since the priority of the medical management after a criticality accident is to assess the dose and the distribution of dose, some dosimetric investigations have been selected in order to provide a prompt response and to anticipate the final dose reconstruction. Comparison exercises between clinical biochemistry laboratories on French sites were carried out to confirm that each laboratory maintained the required operational methods for hair treatment and the appropriate equipment for 32 P activity in hair and 24 Na activity in blood measurements, and to demonstrate its ability to rapidly provide neutron dose estimates after a criticality accident. As a result, a relation has been assessed to estimate the dose and the distribution of dose according to the neutron spectrum following a criticality accident. (authors)

  1. ARDENT to develop advanced dosimetric techniques

    CERN Document Server

    Antonella Del Rosso

    2012-01-01

    Earlier this week, the EU-supported Marie Curie training network ARDENT kicked off at a meeting held at CERN. The overall aim of the project is the development of advanced instrumentation for radiation dosimetry. The applications range from radiation measurements around particle accelerators, onboard commercial flights and in space, to the characterization of radioactive waste and medicine, where accurate dosimetry is of vital importance.   The ARDENT (Advanced Radiation Dosimetry European Network Training) project is both a research and a training programme, which aims at developing new dosimetric techniques while providing 15 Early-Stage Researchers (ESR) with state-of-the-art training. The project, coordinated by CERN, is funded by the European Union with a contribution of about 3.9 million euros over four years. The ARDENT initiative will focus on three main technologies: gas detectors, in particular Gas Electron Multipliers (GEM) and Tissue Equivalent Proportional Counters (TEPC); solid stat...

  2. Dosimetric monitoring in Ukraine - Present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2007-01-01

    Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is required for ∼42,000 occupationally exposed workers, including 9100 in medicine, 17,000 employees of nuclear power plants and ∼16,000 workers dealing with other sources of occupational exposure. This article presents the plan of elaboration of the United System for monitoring and registration of individual doses which has the aim of harmonisation of individual monitoring in Ukraine through securing methodical unity; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programmes; development and support of information infrastructure, in particular operation of the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. (authors)

  3. Dosimetric evaluation of proton stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Min, Byung Jun; Shin, Dong Ho; Yoo, Seung Hoon; Jeong, Hojin; Lee, Se Byeong

    2011-01-01

    Surgical excision, conventional external radiotherapy, and chemotherapy could prolong survival in patients with small intracranial tumors. However, surgical excision for meningiomas located in the region of the base of skull or re-resection is often difficult. Moreover, treatment is needed for patients with recurrent tumors or postoperative residual tumors. Conventional external radiotherapy is popular and has significantly increased for treating brain tumors. Stereotactic radiosurgery is an effective alternative treatment technique to microsurgical resection such as benign brain tumor or vestibular Schwannomas. In general, the dose to OAR of 3D conformal plan is lower than that of conformal arc and dynamic conformal arc plans. However, any of OARs was not reached to tolerance dose. Although mean dose of the healthy brain tissue for 3D conformal plan was slightly higher than that of arc plans, the doses of the healthy brain tissue at V10 and V20 were significantly low for dynamic conformal arc plan. The dosimetric differences were the greatest at lower doses. In contrast, 3D conformal plan was better spare at higher doses. In this study, a dosimetric evaluation of proton stereotactic radiosurgery for brain lesion tumors was using fixed and arc beams. A brass block fitted to the PTV structure was modeled for dynamic conformal collimator. Although all treatment plans offer a very good coverage of the PTV, we found that proton arc plans had significantly better conformity to the PTV than static 3D conformal plan. The V20 dose of normal brain for dynamic conformal arc therapy is dramatically reduced compare to those for other therapy techniques.

  4. Postal auditing methodology used to find out the performance of high rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.

    1998-01-01

    This work describes results from a methodology implemented at the Secondary Laboratory for Dosimetric Calibration at CPHR used to check the brachytherapy performance at high doses rate using Cesium 137 or cobalt 60 sources

  5. Determination of Absorbed Dose Using a Dosimetric Film

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Badita, E.; Mitru, E.

    2009-01-01

    This paper presents the absorbed dose measurements by means of the irradiated dosimetric reference films. The dose distributions were made by MULTIDATA film densitometer using RTD-4 software, in INFLPR Linear Accelerator Department

  6. 39 CFR 262.5 - Systems (Privacy).

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Systems (Privacy). 262.5 Section 262.5 Postal... DEFINITIONS § 262.5 Systems (Privacy). (a) Privacy Act system of records. A Postal Service system containing... individual. (c) Computer matching program. A “matching program,” as defined in the Privacy Act, 5 U.S.C. 552a...

  7. Dosimetric characterization of a bi-directional micromultileaf collimator for stereotactic applications.

    Science.gov (United States)

    Bucciolini, M; Russo, S; Banci Buonamici, F; Pini, S; Silli, P

    2002-07-01

    A 6 MV photon beam from Linac SL75-5 has been collimated with a new micromultileaf device that is able to shape the field in the two orthogonal directions with four banks of leaves. This is the first clinical installation of the collimator and in this paper the dosimetric characterization of the system is reported. The dosimetric parameters required by the treatment planning system used for the dose calculation in the patient are: tissue maximum ratios, output factors, transmission and leakage of the leaves, penumbra values. Ionization chambers, silicon diode, radiographic films, and LiF thermoluminescent dosimeters have been employed for measurements of absolute dose and beam dosimetric data. Measurements with different dosimeters supply results in reasonable agreement among them and consistent with data available in literature for other models of micromultileaf collimator; that permits the use of the measured parameters for clinical applications. The discrepancies between results obtained with the different detectors (around 2%) for the analyzed parameters can be considered an indication of the accuracy that can be reached by current stereotactic dosimetry.

  8. Dosimetric characteristics of biological effect of sulfur-35

    International Nuclear Information System (INIS)

    Borisova, V.V.

    1990-01-01

    Experimental materials related to evaluation of dosimetric characteristics of sulfur-35 are presented. Hemogenic organs are subjected to greatest influence especially in the first hours after radionuclide entry into the organism. Comparison is made of absorbed doses in blood with observed blastomogen effect of hemogenic organs. It is noted, that quantitative evaluation of relative biological efficiency of low energy beta-emitters should be performed with account of dosimetric peculiarities of the nuclides mentioned above. 10 refs.; 3 tabs

  9. Radiation process control, study and acceptance of dosimetric methods

    International Nuclear Information System (INIS)

    Radak, B.B.

    1984-01-01

    The methods of primary dosimetric standardization and the calibration of dosimetric monitors suitable for radiation process control were outlined in the form of a logical pattern in which they are in current use on industrial scale in Yugoslavia. The reliability of the process control of industrial sterilization of medical supplies for the last four years was discussed. The preparatory works for the intermittent use of electron beams in cable industry were described. (author)

  10. Computerized tomography in Community of Madrid. Reference dosimetric measurements

    International Nuclear Information System (INIS)

    Ruiz Sanz, S.; Calzado, A.; Melchor, M.; Marco, M.

    1994-01-01

    A total of about 43 computed tomography scanners were operating in the Autonomous Community of Madrid during 1991. A sample of 14 facilities was selected to perform dosimetric measurements in order to obtain characteristic dose profiles. From these, some quantities as the computed tomography dose index and the enhancement factor were calculated and analysed for the most common technique settings. Relations were established between the dosimetric results and technical characteristics of the scanners. (Author)

  11. Dosimetric tests for treatment planning commissioning in 3DCRT; Testes dosimetricos para comissionamento de sistemas de planejamento em radioterapia 3DCRT

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Leandro R.; Pieri, Karen; Silva, Marco A.; Santos, Gabriela R.; Sales, Camila P.; Rubo, Rodrigo A.; Nakandakari, Marcos V.N.; Cunha, Ana Paula V; Santos, Caroline Z.; Rodrigues, Laura N.; Furnari, Laura, E-mail: leandrorg11@hotmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2012-12-15

    The radiotherapy evolution from 2D treatments to 3D conformal treatments was possible after the advent the treatment planning systems commercially available and tridimensional images techniques like computed tomography. These systems have tools that allow delineate anatomical structures from tomographic images. Calculations dose tools allow the planner evaluate the dose received in the anatomical structures. When these systems are acquired or an upgrade is made many dosimetric and non-dosimetric tests need to be performed to know the system limitations and correct functioning and to verify the correct dosimetric data insertion. This study was based in International Atomic Energy Agency protocols, Task Groups documents from American Association of Physics in Medicine, and other papers. A dosimetric test set was done to commissioning the Eclipse 10.0.28 (Varian Medical Systems) treatments planning system This version has two photon calculation algorithm (Pencil Beam Convolution and Analytical Anisotropic Algorithm – AAA) and Gaussian Pencil Beam algorithm for electron beams. However, tests for AAA it was not performed. In this study was possible to conclude that the dosimetric data was correctly added in the treatment planning system. Some results allowed to understand the algorithm limitations to calculate dose distributions in specifics situations, that was not clinically relevant in our routine. (author)

  12. Development of a dosimetric system for {sup 90}Sr + {sup 90}Y betatherapy applicators; Desenvolvimento de um sistema de dosimetria para aplicadores de betaterapia de {sup 90}Sr + {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Talita Salles

    2010-07-01

    The {sup 90}Sr+{sup 90}Y applicators, used in betatherapy for prevention of keloids and pterigium, are imported and many times their dosimetric features are shown only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of {sup 90}Sr+{sup 90}Y betatherapy applicators. The Monte Carlo code MCNP5 was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry. (author)

  13. The anthrax vaccine and research: reactions from postal workers and public health professionals.

    Science.gov (United States)

    Quinn, Sandra Crouse; Thomas, Tammy; Kumar, Supriya

    2008-12-01

    During the 2001 anthrax attacks, public health agencies faced operational and communication decisions about the use of antibiotic prophylaxis and the anthrax vaccine with affected groups, including postal workers. This communication occurred within an evolving situation with incomplete and uncertain data. Guidelines for prophylactic antibiotics changed several times, contributing to confusion and mistrust. At the end of 60 days of taking antibiotics, people were offered an additional 40 days' supply of antibiotics, with or without the anthrax vaccine, the former constituting an investigational new drug protocol. Using data from interviews and focus groups with 65 postal workers in 3 sites and structured interviews with 16 public health professionals, this article examines the challenges for public health professionals who were responsible for communication with postal workers about the vaccine. Multiple factors affected the response, including a lack of trust, risk perception, disagreement about the recommendation, and the controversy over the military's use of the vaccine. Some postal workers reacted with suspicion to the vaccine offer, believing that they were the subjects of research, and some African American workers specifically drew an analogy to the Tuskegee syphilis study. The consent forms required for the protocol heightened mistrust. Postal workers also had complex and ambivalent responses to additional research on their health. The anthrax attacks present us with an opportunity to understand the challenges of communication in the context of uncertain science and suggest key strategies that may improve communications about vaccines and other drugs authorized for experimental use in future public health emergencies.

  14. Electronic mail was not better than postal mail for surveying residents and faculty.

    Science.gov (United States)

    Akl, Elie A; Maroun, Nancy; Klocke, Robert A; Montori, Victor; Schünemann, Holger J

    2005-04-01

    To compare response rate, time to response, and data quality of electronic and postal surveys in the setting of postgraduate medical education. A randomized controlled trial in a university-based internal medicine residency program. We randomized 119 residents and 83 faculty to an electronic versus a postal survey with up to two reminders and measured response rate, time to response, and data quality. For residents, the e-survey resulted in a lower response rate than the postal survey (63.3% versus 79.7%; difference -16.3%, 95% confidence interval (95% CI) -32.3% to -0.4%%; P=.049), but a shorter mean response time, by 3.8 days (95% CI 0.2-7.4; P=.042). For faculty, the e-survey did not result in a significantly lower response rate than the postal survey (85.4% vs. 81.0%; difference 4.4%, 95% CI -11.7 to 20.5%; P=.591), but resulted in a shorter average response time, by 8.4 days (95% CI 4.4 to 12.4; P < 0.001). There were no differences in the quality of data or responses to the survey between the two methods. E-surveys were not superior to postal surveys in terms of response rate, but resulted in shorter time to response and equivalent data quality.

  15. U.S. Postal Service radon assessment and mitigation program. Progress report, September 1993--November 1994

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez, L.E.; Petty, J.L. Jr.

    1994-12-31

    In 1992, the US Postal Service (USPS) entered into an Interagency Agreement with the Department of Energy (DOE) whereby DOE would provide technical assistance in support of the USPS Radon Assessment and Mitigation Program. To aid in this effort, DOE tasked the Hazardous Waste Remedial Actions Program (HAZWRAP), which is managed by Martin Marietta Energy Systems, Inc., for DOE under contract AC05-84OR21400. Since that time, HAZWRAP has developed and finalized the sampling protocol, mitigation diagnostic protocol, and the quality assurance and quality control procedures. These procedures were validated during the Protocol Validation (1992-1993) and Pilot Study (1993-1994) phases of the program. To date, HAZWRAP has performed approximately 16,000 radon measurements in 250 USPS buildings. Mitigation diagnostics have been performed in 27 buildings. Thus far, 13% of the measurements have been above the Environmental Protection Agency action level of 4 pCi/L. This report summarizes the pilot program radon testing data and mitigation diagnostic data for 22 sites and contains recommendations for mitigation diagnostics.

  16. U.S. Postal Service radon assessment and mitigation program. Progress report, September 1993--November 1994

    International Nuclear Information System (INIS)

    Velazquez, L.E.; Petty, J.L. Jr.

    1994-01-01

    In 1992, the US Postal Service (USPS) entered into an Interagency Agreement with the Department of Energy (DOE) whereby DOE would provide technical assistance in support of the USPS Radon Assessment and Mitigation Program. To aid in this effort, DOE tasked the Hazardous Waste Remedial Actions Program (HAZWRAP), which is managed by Martin Marietta Energy Systems, Inc., for DOE under contract AC05-84OR21400. Since that time, HAZWRAP has developed and finalized the sampling protocol, mitigation diagnostic protocol, and the quality assurance and quality control procedures. These procedures were validated during the Protocol Validation (1992-1993) and Pilot Study (1993-1994) phases of the program. To date, HAZWRAP has performed approximately 16,000 radon measurements in 250 USPS buildings. Mitigation diagnostics have been performed in 27 buildings. Thus far, 13% of the measurements have been above the Environmental Protection Agency action level of 4 pCi/L. This report summarizes the pilot program radon testing data and mitigation diagnostic data for 22 sites and contains recommendations for mitigation diagnostics

  17. A reticle retrofit and dosimetric consideration for a linear accelerator.

    Science.gov (United States)

    Krithivas, V

    1996-01-01

    An imperfect reticle system in an accelerator causes uncertainties in source-skin distance (SSD), off-axis distance (OAD), isocenter, and so forth. A reticle was designed and fabricated, and its implications on x-ray and electron beam dosimetry were investigated. A new reticle frame was dimensioned to fit snugly in the accelerator. The frame was fabricated to carry a pair of adjustable cross wires and to allow the machine operation in the photon and electron modes. The impact of the cross wires on 6 MV photon and 5-10 MeV electron beam parameters such as dose rate (Gy/monitor unit), beam uniformity, surface dose, and so forth, were studied using suitable ion chambers and phantoms. The retrofitted system offered long-term mechanical stability leading to precise SSD, OAD, and isocenter measurements. Changes introduced by the cross wires on the 6 MV photon and 5-10 MeV electron beams are presented. Long-term stability of a reticle in an accelerator is important for an accurate patient setup and for making reliable dosimetric measurements. Beam characteristrics have to be studied whenever modifications on a reticle system are made.

  18. Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams.

    Science.gov (United States)

    Kadoya, Noriyuki; Shimomura, Kouhei; Kitou, Satoshi; Shiota, Yasuo; Fujita, Yukio; Dobashi, Suguru; Takeda, Ken; Jingu, Keiichi; Matsushita, Haruo; Namito, Yoshihito; Ban, Syuichi; Koyama, Syuji; Tabushi, Katsuyoshi

    2012-10-01

    A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosimetric properties of the RGD, including energy dependence of the dose response, reproducibly, variation in data obtained by the RGD for each energy, and angular dependence in low-energy photons, are discussed. An RGD (GD-301, Asahi Techno Glass Corporation, Shizuoka, Japan) was irradiated with monochromatic low-energy photon beams generated by synchrotron radiation at Photon Factory, High Energy Accelerator Research Organization (KEK). The size of GD-301 was 1.5 mm in diameter and 8.5 mm in length and the active dose readout volume being 1 mm diameter and 0.6 mm depth located 0.7 mm from the end of the detector. The energy dependence of the dose response and reproducibility and variation were investigated for RGDs irradiated with a plastic holder and those irradiated without the plastic holder. Response of the RGD was obtained by not only conventional single field irradiation but also bilateral irradiation. Angular dependence of the RGD was measured in the range of 0°-90° for 13, 17, 40, and 80 keV photon beams by conventional single field irradiation. The dose responses had a peak at around 40 keV. For the energy range of less than 25 keV, all dose response curves steeply decreased in comparison with the ratio of mass energy absorption coefficient of the RGD to that of air. As for the reproducibility and variation in data obtained by the RGD, the coefficient of variance increased with decrease in photon energy. Furthermore, the variation for bilateral irradiation was less than that for single field irradiation. Regarding angular dependence of the RGD, for energies of 13 and 17 keV, the response decreased with increase in the irradiation angle, and the

  19. Dosimetric Comparison of Helical Tomotherapy and Dynamic Conformal Arc Therapy in Stereotactic Radiosurgery for Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Lee, Tsair-Fwu; Chao, Pei-Ju; Wang, Chang-Yu; Lan, Jen-Hong; Huang, Yu-Je; Hsu, Hsuan-Chih; Sung, Chieh-Cheng; Su, Te-Jen; Lian, Shi-Long; Fang, Fu-Min

    2011-01-01

    The dosimetric results of stereotactic radiosurgery (SRS) for vestibular schwannoma (VS) performed using dynamic conformal arc therapy (DCAT) with the Novalis system and helical TomoTherapy (HT) were compared using plan quality indices. The HT plans were created for 10 consecutive patients with VS previously treated with SRS using the Novalis system. The dosimetric indices used to compare the techniques included the conformity index (CI) and homogeneity index (HI) for the planned target volume (PTV), the comprehensive quality index (CQI) for nine organs at risk (OARs), gradient score index (GSI) for the dose drop-off outside the PTV, and plan quality index (PQI), which was verified using the plan quality discerning power (PQDP) to incorporate 3 plan indices, to evaluate the rival plans. The PTV ranged from 0.27-19.99 cm 3 (median 3.39 cm 3 ), with minimum required PTV prescribed doses of 10-16 Gy (median 12 Gy). Both systems satisfied the minimum required PTV prescription doses. HT conformed better to the PTV (CI: 1.51 ± 0.23 vs. 1.94 ± 0.34; p < 0.01), but had a worse drop-off outside the PTV (GSI: 40.3 ± 10.9 vs. 64.9 ± 13.6; p < 0.01) compared with DCAT. No significant difference in PTV homogeneity was observed (HI: 1.08 ± 0.03 vs. 1.09 ± 0.02; p = 0.20). HT had a significantly lower maximum dose in 4 OARs and significant lower mean dose in 1 OAR; by contrast, DCAT had a significantly lower maximum dose in 1 OAR and significant lower mean dose in 2 OARs, with the CQI of the 9 OARs = 0.92 ± 0.45. Plan analysis using PQI (HT 0.37 ± 0.12 vs. DCAT 0.65 ± 0.08; p < 0.01), and verified using the PQDP, confirmed the dosimetric advantage of HT. However, the HT system had a longer beam-on time (33.2 ± 7.4 vs. 4.6 ± 0.9 min; p < 0.01) and consumed more monitor units (16772 ± 3803 vs. 1776 ± 356.3; p < 0.01). HT had a better dose conformity and similar dose homogeneity but worse dose gradient than DCAT. Plan analysis confirmed the dosimetric advantage of HT

  20. TU-D-9A-01: TG176: Dosimetric Effects of Couch Tops and Immobilization Devices

    International Nuclear Information System (INIS)

    Olch, A

    2014-01-01

    The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices are often overlooked. These devices also increase surface dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased surface dose compared to the ‘tennis racket’ style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations we make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of skin dose and attenuation, how to report these values, and for the vendors, an appeal is made to work together to provide accurate couch top models in planning systems. Learning Objectives

  1. SU-F-T-19: The Consistency Dosimetric Analysis of the Accelerated Breast Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pinder, J; Chandrasekara, S; Pella, S [21st Century Oncology, Boca Raton, FL (United States)

    2016-06-15

    Purpose: To assess the best approach in accept a treatment plan for APBI Savi patients. Should we run a treatment verification test prior to delivering it to the patient? Should we check each CT scan in regards to the initial one in dosimetrical terms? Do we need deformable registration and adaptive planning for each fraction? These are the questions we want to answer running a dosimetric analysis of the dose variances for APBI treatments who receive 10 fractions and no re-planning has been done being considered unnecessary with today’s means of assessment. Methods: A retrospective analysis of 30 patients treated with SAVI applicators were considered for this study. The CT scans taken before each treatment were imported in the treatment planning system and registered with the initial CT scan. The images were fused together with respective to the applicator, using landmark registration. Dosimetric evaluations were performed. Dose received by skin, ribs and PTV on CT images with respect to the initial treatment plan were recorded including maximum, average and minimum dose Results: All the structures displayed changes in volume over the 10 fractions of treatment. The cavities reduction in volume was considerable with a maximum reduction of over 10%. The PTV-eval is covered better due to this fact while the critical organs manifest an increase in the total and maximum dose delivered. Ribs and skin surface that are required by B39 protocol to be monitored can acquire maximum doses of 20% to 30% respectively. Conclusion: A dosimetric evaluation prior to the initial treatment and prior to each of the 10 fractions is proven to be necessary. Deformable registration and adaptive planning have to be studied more and eventually implemented for every patient who received more than one fraction of any type of brachytherapy treatment. Immobilization ad localization methods must be improved and studied further.

  2. Effect of photon energy spectrum on dosimetric parameters of brachytherapy sources.

    Science.gov (United States)

    Ghorbani, Mahdi; Mehrpouyan, Mohammad; Davenport, David; Ahmadi Moghaddas, Toktam

    2016-06-01

    The aim of this study is to quantify the influence of the photon energy spectrum of brachytherapy sources on task group No. 43 (TG-43) dosimetric parameters. Different photon spectra are used for a specific radionuclide in Monte Carlo simulations of brachytherapy sources. MCNPX code was used to simulate 125I, 103Pd, 169Yb, and 192Ir brachytherapy sources. Air kerma strength per activity, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated and isodose curves were plotted for three different photon energy spectra. The references for photon energy spectra were: published papers, Lawrence Berkeley National Laboratory (LBNL), and National Nuclear Data Center (NNDC). The data calculated by these photon energy spectra were compared. Dose rate constant values showed a maximum difference of 24.07% for 103Pd source with different photon energy spectra. Radial dose function values based on different spectra were relatively the same. 2D anisotropy function values showed minor differences in most of distances and angles. There was not any detectable difference between the isodose contours. Dosimetric parameters obtained with different photon spectra were relatively the same, however it is suggested that more accurate and updated photon energy spectra be used in Monte Carlo simulations. This would allow for calculation of reliable dosimetric data for source modeling and calculation in brachytherapy treatment planning systems.

  3. Dosimetric assessment of swallowing examinations with videofluoroscopy

    International Nuclear Information System (INIS)

    Costa, M.M.B.; Canevaro, L.V.; Azevedo, A.C.P.

    2001-01-01

    Dosimetric analysis measurements of the Dose-Area-Product (DAP) of 7 individuals were estimated for the deglutition dynamic using the videofluoroscopic method. The aim of this study is to establish in a preliminary way, typical DAP values for this kind of study. The DAP values were obtained attaching to the X ray tube exit, an ionization chamber from PTW and a Diamentor M4 meter. The typical DAP values obtained during the videofluoroscopic evaluation of the deglutition dynamic, including its three phases, was: 4101 ± 881 cGy.cm 2 and the typical DAP rate was 577 ± 94 cGy.cm 2 /min. These values refer to a standard patient (1.57 cm height, 56 kg. weight) and a protocol that can be performed in about 7 minutes. The values, defined herein as typical refer to the used protocol. To our knowledge, the mean DAP rate is a good parameter to estimate radiation exposure from videofluoroscopic study of swallowing process. (author)

  4. Dosimetric feature of natural biotite mineral

    International Nuclear Information System (INIS)

    Kalita, J.M.; Wary, G.

    2015-01-01

    A thermoluminescence (TL) study relevant to radiation dosimetry has been carried out for X-ray irradiated biotite mineral under un-annealed and different annealed (473, 573, 673 and 773 K) conditions. Some significant variations in dosimetric characteristics have been observed with annealing treatment. Due to generation of an additional shallow trap level at depth 0.78 eV in 673 and 773 K annealed samples, the dose response is found to improve. For the 773 K annealed sample, a linear dose response has been observed from 10 to 1100 mGy. The fading is ∼13 % within 5 d after irradiation and onward it reduces to 7 % up to 60 d. Reproducibility of this (773 K) sample is excellent. After 10 recycles the coefficient of variations in the results for the 60, 180 and 1000 mGy dose-irradiated samples are found to be 0.97, 1.31 and 1.03 %, respectively. The potential use of biotite as a natural X-ray dosemeter is discussed. (authors)

  5. Neutron sources and its dosimetric characteristics

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado S, G.A.; Gallego D, E.; Lorente F, A.

    2005-01-01

    By means of Monte Carlo methods the spectra of the produced neutrons 252 Cf, 252 Cf/D 2 O, 241 Am Be, 239 Pu Be, 140 La Be, 239 Pu 18 O 2 and 226 Ra Be have been calculated. With the information of the spectrum it was calculated the average energy of the neutrons of each source. By means of the fluence coefficients to dose it was determined, for each one of the studied sources, the fluence factors to dose. The calculated doses were H, H * (10), H p,sIab (10, 0 0 ), E AP and E ISO . During the phase of the calculations the sources were modeled as punctual and their characteristics were determined to 100 cm in the hole. Also, for the case of the sources of 239 Pu Be and 241 Am Be, were carried out calculations modeling the sources with their respective characteristics and the dosimetric properties were determined in a space full with air. The results of this last phase of the calculations were compared with the experimental results obtained for both sources. (Author)

  6. Dosimetric characterization of two radium sources for retrospective dosimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Karlsson, M. [Division of Radiological Sciences, Department of Medical and Health Sciences, Linköping University, Linköping SE 581 85 (Sweden); Lundell, M. [Department of Medical Physics and Oncology, Karolinska University Hospital and Karolinska Institute, Stockholm SE 171 76 (Sweden); Ballester, F. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Tedgren, Å. Carlsson [Division of Radiological Sciences, Department of Medical and Health Sciences, Linköping University, Linköping SE 581 85, Sweden and Swedish Radiation Safety Authority, Stockholm SE 171 16 (Sweden)

    2015-05-15

    Purpose: During the first part of the 20th century, {sup 226}Ra was the most used radionuclide for brachytherapy. Retrospective accurate dosimetry, coupled with patient follow up, is important for advancing knowledge on long-term radiation effects. The purpose of this work was to dosimetrically characterize two {sup 226}Ra sources, commonly used in Sweden during the first half of the 20th century, for retrospective dose–effect studies. Methods: An 8 mg {sup 226}Ra tube and a 10 mg {sup 226}Ra needle, used at Radiumhemmet (Karolinska University Hospital, Stockholm, Sweden), from 1925 to the 1960s, were modeled in two independent Monte Carlo (MC) radiation transport codes: GEANT4 and MCNP5. Absorbed dose and collision kerma around the two sources were obtained, from which the TG-43 parameters were derived for the secular equilibrium state. Furthermore, results from this dosimetric formalism were compared with results from a MC simulation with a superficial mould constituted by five needles inside a glass casing, placed over a water phantom, trying to mimic a typical clinical setup. Calculated absorbed doses using the TG-43 formalism were also compared with previously reported measurements and calculations based on the Sievert integral. Finally, the dose rate at large distances from a {sup 226}Ra point-like-source placed in the center of 1 m radius water sphere was calculated with GEANT4. Results: TG-43 parameters [including g{sub L}(r), F(r, θ), Λ, and s{sub K}] have been uploaded in spreadsheets as additional material, and the fitting parameters of a mathematical curve that provides the dose rate between 10 and 60 cm from the source have been provided. Results from TG-43 formalism are consistent within the treatment volume with those of a MC simulation of a typical clinical scenario. Comparisons with reported measurements made with thermoluminescent dosimeters show differences up to 13% along the transverse axis of the radium needle. It has been estimated that

  7. Morocco : Spanish postal administration after 1912 and Morocco during the Spanish Civil War and the Second World War

    NARCIS (Netherlands)

    Dietz, A.J.

    2017-01-01

    An earlier version of (parts of) APH 5 was published as African Studies Centre Leiden Working Paper 125 / 2016: "A postal history of the First World War in Africa and its aftermath - German colonies/postal areas : V Morocco", written by Ton Dietz.

  8. 39 CFR 111.1 - Mailing Standards of the United States Postal Service, Domestic Mail Manual; incorporated by...

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Mailing Standards of the United States Postal Service, Domestic Mail Manual; incorporated by reference of regulations governing domestic mail services... the approval of the Director of the Federal Register.” In conformity with that provision, and with 39...

  9. Development of optimized dosimetric models for HDR brachytherapy

    International Nuclear Information System (INIS)

    Thayalan, K.; Jagadeesan, M.

    2003-01-01

    High dose rate brachytherapy (HDRB) systems are in clinical use for more than four decades particularly in cervical cancer. Optimization is the method to produce dose distribution which assures that doses are not compromised at the treatment sites whilst reducing the risk of overdosing critical organs. Hence HDRB optimization begins with the desired dose distribution and requires the calculations of the relative weighting factors for each dwell position with out changing the source activity. The optimization for Ca. uterine cervix treatment is simply duplication of the dose distribution used for Low dose rate (LDR) applications. In the present work, two optimized dosimetric models were proposed and studied thoroughly, to suit the local clinical conditions. These models are named as HDR-C and HDR-D, where C and D represent configuration and distance respectively. These models duplicate exactly the LDR pear shaped dose distribution, which is a golden standard. The validity of these models is tested in different clinical situations and in actual patients (n=92). These models: HDR-C and HDR-D reduce bladder dose by 11.11% and 10% and rectal dose by 8% and 7% respectively. The treatment time is also reduced by 12-14%. In a busy hospital setup, these models find a place to cater large number of patients, while addressing individual patients geometry. (author)

  10. Study on dosimetric properties of radiophotoluminescent glass rod detector

    Energy Technology Data Exchange (ETDEWEB)

    Rah, Jeong Eun; Hong, Ju Young; Suh, Tea Suk [The Catholic University of Korea, Seoul (Korea, Republic of); Shin, Dong Oh [Kyunghee Univ., Seoul (Korea, Republic of); Kim, Hee Sun [Korea Hydro and Nuclear Power Co., Ltd, Daejeon (Korea, Republic of); Lim, Chun Il; Jeong, Hee Gyo [Korea Food and Drug Administration, Seoul (Korea, Republic of)

    2006-12-15

    A radiophotoluminescent Glass Rod Detector (GRD) system has recently become commercially available. We investigate the dosimetric properties of the GRD regarding the reproducibility of signal, dose linearity and energy dependence. The reproducibility of five measurements for 50 GRDs is presented by an average of one standard deviation of each GRD and it is {+-}1.2%. It is found to be linear in response to doses of {sup 60}Co beam in the range 0.5 to 50 Gy with a coefficient of linearity of 0.9998. The energy dependence of the GRD is determined by comparing the dose obtained using cylindrical chamber to that by using the GRD. The GRD response for each beam is normalized to the response for a {sup 60}Co beam. The responses for 6 and 15 MV x-ray beams are within {+-}1.5% (1SD). The energy response of GRD for high-energy photon is almost the same as the energy dependence of LiF:Mg:Ti (TLD-100) and shows little energy dependence unlike p-type silicon diode detector. The GRDs have advantages over other detectors such diode detector, and TLD: linearity, reproducibility and energy dependency. It has been verified to be an effective device for small field dosimetry for stereotactic radiosurgery.

  11. Active pixel as dosimetric device for interventional radiology

    International Nuclear Information System (INIS)

    Servoli, L.; Baldaccini, F.; Biasini, M.; Checcucci, B.; Chiocchini, S.; Cicioni, R.; Conti, E.; Di Lorenzo, R.; Dipilato, A.C.; Esposito, A.; Fanó, L.; Paolucci, M.; Passeri, D.; Pentiricci, A.

    2013-01-01

    Interventional Radiology (IR) is a subspecialty of radiology comprehensive of all minimally invasive diagnostic and therapeutic procedures performed using radiological devices to obtain image guidance. The interventional procedures are potentially harmful for interventional radiologists and medical staff due to the X-ray diffusion by the patient's body. The characteristic energy range of the diffused photons spans few tens of keV. In this work we will present a proposal for a new X-ray sensing element in the energy range of interest for IR procedures. The sensing element will then be assembled in a dosimeter prototype, capable of real-time measurement, packaged in a small form-factor, with wireless communication and no external power supply to be used for individual operators dosimetry for IR procedures. For the sensor, which is the heart of the system, we considered three different Active Pixel Sensors (APS). They have shown a good capability as single X-ray photon detectors, up to several tens keV photon energy. Two dosimetric quantities have been considered, the number of detected photons and the measured energy deposition. Both observables have a linear dependence with the dose, as measured by commercial dosimeters. The uncertainties in the measurement are dominated by statistic and can be pushed at ∼5% for all the sensors under test

  12. Dosimetric properties of commercial glasses and sand for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines

    2004-01-01

    Commercial glasses (transparent and colored) produced by Cebrace, Brazil, Sao Paulo, and sand samples of different Brazilian beaches were studied, due to their low cost and easy handling, to verify the possibility of their use in high dose dosimetry. The main dosimetric characteristics were determined using a densitometer, a spectrophotometer, a thermoluminescent (TL) reader and an electronic paramagnetic resonance system. The gamma irradiations were carried out using a Gamma-Cell 220 and a panoramic source ( 60 Co) of IPEN. An optical absorption band was observed at 420 nm in the glass samples. The TL glow curves presented peaks at 205 deg C, 135 deg C, 150 deg C and 145 deg C for the transparent, bronze, brown and green glass samples, respectively. All EPR spectra of the glasses showed Fe 3+ characteristic signals at g = 4.27 and 2.01. The gamma irradiated sand samples presented two peaks at 110 deg C and 170 deg C and an EPR signal at g= 1.999. However, these materials present a pronounced thermal fading at room temperature after irradiation. With the objective to minimize this thermal fading, both glass and sand samples were submitted to different pre- and post-irradiation thermal treatments. The glass and sand samples showed the possibility of utilization for high dose dosimetry and as Yes/No irradiation detectors. (author)

  13. Dosimetric analysis of radiation sources for use dermatological lesions

    International Nuclear Information System (INIS)

    Tada, Ariane

    2010-01-01

    Skin lesions undergoing therapy with radiation sources may have different patterns of malignancy. Malignant lesions or cancer most commonly found in radiotherapy services are carcinomas. Radiation therapy in skin lesions is performed with low penetration beams and orthovoltage X-rays, electron beams and radioactive sources ( 192 Ir, 198 Au, e 90 Sr) arranged on a surface mold or in metal applicator. This study aims to analyze the therapeutic radiation dose profile produced by radiation sources used in skin lesions radiotherapy procedures . Experimental measurements for the analysis of dosimetric radiation sources were compared with calculations obtained from a computer system based on the Monte Carlo Method. Computational results had a good agreement with the experimental measurements. Experimental measurements and computational results by the MCNP4C code were both physically consistent as expected. These experimental measurements compared with calculations using the MCNP-4C code have been used to validate the calculations obtained by MCNP code and to provide a reliable medical application for each clinical case. (author)

  14. TLD postal dose quality audit service for Co-60 beams in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    This report presents the methodology and experience of the Cuban's Secondary Standard Dosimetry Laboratory for the implementation of postal dose quality audits service for Co-60 beams in reference conditions, using TLDs. Under coordinated research project (Contract 10794) were bought (TLD -100) Tl rods type JR 1152F made in China, with dimensions of 6 mm x 1 mm x 1 mm. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout (100 rods approximately), four serial times in the same geometrical conditions, to read them out and to attribute to each of them a sensitivity factor. This sensitivity factor is equal to average for the 4 cycle of irradiation and readout of the quote between the TL readout from dosimeter i and the mean of all values for each cycle. The TLD signal was read using HARSHAW 2000C/B reader. The results obtained in the external verification of the accuracy of the dose determination by the TLD system were performed in cooperation with IAEA Dosimetry Laboratory at Seibersdorf in different years are shown, the results obtained of the quality audits carried out to the different services of radiotherapy of the country are analysed also. The quality audits are an useful tool for the improvement of the accuracy in the dosimetry of clinical beams of radiotherapy with Co-60, contributing this way to the improvement of the life quality to cancer patients of the Cuban system of health. (author)

  15. The Ethanol-Chlorobenzene Aerated System as a New High-Level Dosimeter for Routine Measurements; Le Systeme Ethanol-Chlorobenzene Aere Utilise Comme Dosimetre pour les Mesures Courantes de Fortes Doses; Aehrirovannaya sistema ehtanola-khlorobenzola v kachestve novogo dozimetra vysokogo urovnya dlya provedeniya obychnykh izmerenij; Dosimetro de Etanol-Clorobenceno Saturado de Aire para la Determinacion de Intensidades Elevadas

    Energy Technology Data Exchange (ETDEWEB)

    Dvornik, I.; Zec, U.; Ranogajec, F. [Institute ' ' Ruder Boskovic' ' , Zagreb, Yugoslavia (Croatia)

    1966-11-15

    The radiolytic hydrogen chloride yield for {sup 60}Co gamma radiation measured as a function of dose (0.05 to 100 Mrad), dose-rate (0.5 to 2500 rad sec{sup -1}) and chlorobenzene (CB) concentration is found to be 5 {+-} 0.1 for CB concentrations between 20 and 40% in a broad range of experimental conditions. The yield is only slightly sensitive to normal impurities. Analytical and lower-grade components give yields reproducible within a few per cent of this value if 4% water and about 2X 10{sup -3} M benzene and acetaldehyde or acetone are initially present. Higher dosimetric accuracy is obtained if the exact G(Cl{sup -}) is determined for given materials by calibration with the Fricke dosimeter. With 4% CB and 4 Degree-Sign Inverted-Exclamation-Mark o water all grades of ethanol give G(Cl{sup -}) = 3.65 {+-} 0.05, irrespective of additives. The effect of variation of the water content within {+-} 1% is negligible. The hydrogen chloride concentration in the whole dose range is determined by mercurimetric or alkali- metric titration directly in the irradiated sample with an accuracy of one per cent or better. Incomplete experiments with fast electrons have proved that similar systems are of possible interest for calibration and control of industrial irradiations with intense electron beams. The simplicity of preparation and analysis together with the broad range (covered by only one analytical method) and high overall accuracy give to the new dosimeter all the qualities of the almost unique tool for dosimetric calibration of sources and routine control of industrial radiation processing. (author) [French] On constate que la quantite d'acide chlorhydrique radiolytique produite par des rayons gamma emis par le {sup 60}Co, mesuree en fonction de la dose (0,05 a 100 Mrad), du debit de dose (0,5 a 2500 rad-s{sup -1}) et de la concentration du chlorobenzene (CB), est de 5 {+-} 0,1 pour des concentrations de CB comprises entre 20 et 40% dans un tres large eventail de

  16. Tracheostomy for long-term ventilated patients: a postal survey of ICU practice in The Netherlands.

    NARCIS (Netherlands)

    Fikkers, B.G.; Fransen, G.A.J.; Hoeven, J.G. van der; Briede, I.S.; Hoogen, F.J.A. van den

    2003-01-01

    OBJECTIVE: To assess the frequency, timing, technique, and follow-up of tracheostomy for long-term ventilated patients in different intensive care units (ICUs) in The Netherlands. DESIGN AND SETTING: Postal questionnaire, survey on retrospective data. A questionnaire was sent to all ( n=63) ICUs

  17. Anaesthetic management of the airway in The Netherlands : a postal survey

    NARCIS (Netherlands)

    Borg, PAJ; Stuart, C; Dercksen, B; Eindhoven, GB

    2001-01-01

    Backgound and objective A postal survey was conducted in order to investigate current practice in airway management amongst Dutch anaesthetists and to investigate the role of recent training and the role of an 'Access to the Airway' airway management course. Methods A questionnaire containing 27

  18. 37 CFR 201.8 - Disruption of postal or other transportation or communication services.

    Science.gov (United States)

    2010-07-01

    ... transportation or communication services. 201.8 Section 201.8 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.8 Disruption of postal or other transportation or communication services. (a) For purposes of 17 U.S.C. 709, when the...

  19. ANALYSIS AND PERSPECTIVES OF PRIVATE POSTAL AND COURIER SERVICES IN ROMANIA DURING 2009-2015

    Directory of Open Access Journals (Sweden)

    Silviu Dorin GEORGESCU

    2013-11-01

    Full Text Available Services occupy an important role in a country’s economic development. At present, services sector is under a continuous change and diversification, for this reason theoretical and practical approaches are both difficult and controversial. Services have complex forms of manifestation, being involved in all compartments of economic and social life; have a heterogeneous character (Criveanu, 2009, p.13. The evaluation and measurement of postal services sector through some indicators, such as: the population occupied in this sector and its change in time; internal and international traffic of mail; degree of employees’ burden. The development of postal and courier sector during the period preceding 2009 was influenced by external factors such as the growth of the GDP, the development of niche segments, the ascending trend being a normal consequence of the evolution of the entire national economy. Although the field of postal services has felt the evolution of national economy and the effects of the economic crisis, the strategies adopted by private companies in this sector have demonstrated the necessity of knowing the market, its evolutions and perspectives. The present paper aims at analyzing the evolution of postal and courier services in Romania during 2009-2012, a period marked by the profound economic crisis which affected Romania and the European Union, as well as the perspectives regarding the number of employees in this sector within private companies in Romania during 2013-2015 using statistical methods to forecast the employed population in private companies in this sector.

  20. 39 CFR 447.52 - Holding of State or local office by Postal Service employees.

    Science.gov (United States)

    2010-07-01

    ... ascertaining: (1) Whether the office is “nonpartisan” within the definition in § 447.62(a). (2) Whether State... encouraged to seek advice from his Associate Ethical Conduct Counselor prior to taking any action to seek... that the employee's postal responsibilities are being conducted in a satisfactory manner and that the...

  1. Dental radiography ten years ago and now: overview of results of postal TLD audit

    International Nuclear Information System (INIS)

    Vtelenska, M.; Novak, L.

    2014-01-01

    Since 2002, regular postal audit in dental radiography organized by NRPI Prague belongs to basic radiography QA/QC tools in the Czech Republic. The measured parameters are incident air kerma, field size, and exposure reproducibility. The overall quality of the dental radiograph is also assessed. Ten-year summary of the audit results is presented here. (authors)

  2. 39 CFR 3050.21 - Content of the Postal Service's section 3652 report.

    Science.gov (United States)

    2010-07-01

    ... competitive advantage for the Postal Service or any mailer. (i) For each nonpostal service, estimate its costs... unreasonable. (g) For each competitive negotiated service agreement: (1) Identify its rates and service... and by competitive product group; (2) Estimate the quality of service of each individual experimental...

  3. 75 FR 16837 - Public Review of Draft United States Thoroughfare, Landmark, and Postal Address Data Standard

    Science.gov (United States)

    2010-04-02

    ... comments shall be sent to Julie Binder Maitra, of the FGDC Secretariat via electronic mail, [email protected] electronic addresses such as e-mail addresses. It recognizes that some organizations are prohibited by..., participants will receive written notification of how their comments were addressed by electronic or postal...

  4. The development of a postal method to assess X-ray beam parameters and image quality in dental radiology

    International Nuclear Information System (INIS)

    Fenton, D.M.

    1994-10-01

    postal system differs from other similar methods in that in addition to these parameters an evaluation of the image quality is made

  5. Dosimetric measurements of an n-butyl cyanoacrylate embolization material for arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Labby, Zacariah E., E-mail: zelabby@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin–Madison, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Chaudhary, Neeraj [Division of Neurointerventional Radiology, Departments of Radiology and Neurosurgery, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Gemmete, Joseph J. [Division of Neurointerventional Radiology, Departments of Radiology, Neurosurgery, and Otolaryngology, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Pandey, Aditya S. [Department of Neurosurgery, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Roberts, Donald A. [Radiation Physics Division, Department of Radiation Oncology, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States)

    2015-04-15

    Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derived from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner’s HU calibration curve. Results: The ELAC was 0.0516 ± 0.0063 cm{sup −1} and 0.0580 ± 0.0091 cm{sup −1} for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm{sup −1} for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of −0.29% and −0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively

  6. Dosimetric essay in dental radiology; Experiencia dosimetrica en radiologia odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Salaberry, M [Ministerio de Industria, Energia y Mineria, Montevideo (Uruguay). Direccion Nacional de Tecnologia Nuclear; Dato Carfagna, A; Rodriguez Dorgia, R [Universidad de la Republica, Facultad de Odontologia , Montevideo (Uruguay)

    1999-12-31

    A neck study was observated in the tiroids glands,laryngeal zone, sensitive organs for the ionizing radiation for increase dental xray exams. Was selected 29th patients with radiography prescription complete (in the Odontology Faculty Clinics Uruguaian). It took radiographies with and without tiroids necklace and apron lead using dosemeters. Dosimetric studies had demonstrated good dose between patients. For measuring the radiation dose have been used TLD thermoluminescence dosimetric and Harshaw 6600 for read it. The thyroids necklace use and odontology postgrading for training course for dentistry was the two recommendations advised

  7. A RCT evaluating the effectiveness and cost-effectiveness of academic detailing versus postal prescribing feedback in changing GP antibiotic prescribing.

    LENUS (Irish Health Repository)

    Naughton, Corina

    2009-10-01

    The aim of this study is to evaluate the effectiveness of academic detailing (AD) plus postal prescribing feedback versus postal prescribing feedback alone in reducing: (i) the overall rate of antibiotic; and (ii) proportion of second-line antibiotic prescribing. In addition, the cost-effectiveness of an outreach prescriber adviser service versus a postal prescribing feedback service was evaluated.

  8. Assessment of dosimetrical performance in 11 Varian a-Si500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Kavuma, Awusi; Glegg, Martin; Currie, Garry; Elliott, Alex

    2008-01-01

    Dosimetrical characteristics of 11 Varian a-Si-500 electronic portal imaging devices (EPIDs) in clinical use for periods ranging between 10 and 86 months were investigated for consistency of performance and portal dosimetry implications. Properties studied include short-term reproducibility, signal linearity with monitor units, response to reference beam, signal uniformity across the detector panel, signal dependence on field size, dose-rate influence, memory effects and image profiles as a function of monitor units. The EPID measurements were also compared with those of the ionization chambers' to ensure stability of the linear accelerators. Depending on their clinical installation date, the EPIDs were interfaced with one of the two different acquisition control software packages, IAS2/IDU-II or IAS3/IDU-20. Both the EPID age and image acquisition system influenced the dosimetric characteristics with the newer version (IAS3 with IDU-20) giving better data reproducibility and linearity fit than the older version (IAS2 with IDU-II). The relative signal response (uniformity) after 50 MU was better than 95% of the central value and independent of detector. Sensitivity for all EPIDs reduced continuously with increasing dose rates for the newer image acquisition software. In the dose-rate range 100-600 MU min -1 , the maximum variation in sensitivity ranged between 1 and 1.8% for different EPIDs. For memory effects, the increase in the measured signal at the centre of the irradiated field for successive images was within 1.8% and 1.0% for the older and newer acquisition systems, respectively. Image profiles acquired at a lower MU in the radial plane (gun-target) had gradients in measured pixel values of up to 25% for the older system. Detectors with software/hardware versions IAS3/IDU-20 have a high degree of accuracy and are more suitable for routine quantitative IMRT dosimetrical verification.

  9. TL dosimetric properties BAM:EU

    International Nuclear Information System (INIS)

    Rao, Bellam N.; Murthy, K.V.R.; Subba Rao, B.; Saiprasad, A.S.

    2011-01-01

    In phosphor area today top priority is the replacement of the high performance but very expensive rare earth activated phosphors with cheaper materials. This essentially means replacing the rare earth ions with transition metal ions or post transition ions. Now a day's phosphors are used in various fields. After World War II, the advances in the optical spectroscopy of solids, especially those of transition metals ions help to evolve research on phosphor and solid state luminescence. In 1960 efficient rare earth activated phosphors were developed for use in color TV (Tb 3+ green, Eu 3+ red, and Dy 3+ yellow). In 1970 tricolor lamp was introduced blue emission from Ce 3+ + Tb 3+ pair was used in tricolor lamps. At present combination of halo phosphor and tri-band phosphor blend is used in many lamp as a compromise between performance, phosphor cost and the lamp making Cost. Thermo luminescence of 0.5 Gy X-ray irradiated BAM.Eu has been studied. The irradiated phosphor has been studied for its TL dosimetric properties one week after irradiation and after 100 weeks of storage. Interesting TL results are reported in the present paper. Heating rate used in the present experiment is 6.6 deg C/Sec. The following two figures are on TL recorded 100 weeks after irradiation and TL recorded after 235 weeks of storage. Before storage for 100 weeks the TL glow curve with a hump around 180 deg C followed by a peak at 273 deg C. After storage for 100 weeks the TL pattern changes entirely. i.e. the composite TL peak structure emerged as two well resolved peaks and with slightly higher TL peak temperatures at 215 deg C and 300 deg C. Normally after storage for 100 weeks the peak at 190 deg C reduces in its intensity or disappears in some cases, instead of that the peak appears at 215 deg C as well resolved peak and its intensity is almost comparable to that of 300 deg C peak. Since the TL phenomenon observed is interesting the two well resolved, isolated, high intensity peaks

  10. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.L. E-mail: orkarl@polyu.edu.hk

    2004-05-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV{sub p} in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations.

  11. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    International Nuclear Information System (INIS)

    Fung, K.L.

    2004-01-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV p in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations

  12. A spectrophotometric readout for γ irradiated alanine solution - a dosimetric application

    International Nuclear Information System (INIS)

    Marzouk, Asma

    2007-01-01

    Alanine is a stable dosimeter of reference in its solid state. Its installation in solution as being a dosimetric system of routine remains very useful. A follow-up of the behaviour of the irradiated alanine solution with 15 kGy according to the concentration is carried out by UV-Visible spectrophotometry. The results obtained prove the difficulty in analytical studies of the radiolysis of aqueous solutions by optical absorption due to the ambiguous broad spectra of the species and the reaction products. (Author). 47 refs

  13. Compartmental and dosimetric studies of anti-CD20 labeled with 188Re

    International Nuclear Information System (INIS)

    Barrio Kuramoto Graciela; Mie Nakamura Matsuda Margareth; Osso Joao Jr, Alberto

    2016-01-01

    Radioimmunotherapy has the potential to deliver lethal radiation energy directly to malignant cells via targeting of radioisotope-conjugated monoclonal antibodies (MAbs) to specific antigens. Rituximab (RTX) is specifically targeted against CD20, a surface antigen expressed by B-lymphocytes. The use of 188 Re from a 188 W/ 188 Re generator system represents an alternative radionuclide for therapy. Rhenium has chemical properties similar to technetium and both can be conjugated to antibodies using similar chemistry methods. The objective of this work is to prove the usefulness of this radiopharmaceutical based on dosimetric and pharmacokinetic studies that are also required by the Brazilian Regulatory Agency. (author)

  14. The revised International Commission on Radiological Protection (ICRP) dosimetric model for the human respiratory tract

    International Nuclear Information System (INIS)

    Bair, W.J.

    1992-05-01

    A task group has revised the dosimetric model of the respiratory tract used to calculate annual limits on intake of radionuclides. The revised model can be used to project respiratory tract doses for workers and members of the public from airborne radionuclides and to assess past exposures. Doses calculated for specific extrathoracic and thoracic tissues can be adjusted to account for differences in radiosensitivity and summed to yield two values of dose for the respiratory tract that are applicable to the ICRP tissue weighted dosimetry system

  15. Dosimetric effects of an air cavity for the SAVI partial breast irradiation applicator

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Susan L.; Pino, Ramiro [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, Methodist Hospital, Houston, Texas 77030 and Texas Cancer Clinic, San Antonio, Texas 78240 (United States)

    2010-08-15

    Purpose: To investigate the dosimetric effect of the air inside the SAVI partial breast irradiation device. Methods: The authors have investigated how the air inside the SAVI partial breast irradiation device changes the delivered dose from the homogeneously calculated dose. Measurements were made with the device filled with air and water to allow comparison to a homogenous dose calculation done by the treatment planning system. Measurements were made with an ion chamber, TLDs, and film. Monte Carlo (MC) simulations of the experiment were done using the EGSnrc suite. The MC model was validated by comparing the water-filled calculations to those from a commercial treatment planning system. Results: The magnitude of the dosimetric effect depends on the size of the cavity, the arrangement of sources, and the relative dwell times. For a simple case using only the central catheter of the largest device, MC results indicate that the dose at the prescription point 1 cm away from the air-water boundary is about 9% higher than the homogeneous calculation. Independent measurements in a water phantom with a similar air cavity gave comparable results. MC simulation of a realistic multidwell position plan showed discrepancies of about 5% on average at the prescription point for the largest device. Conclusions: The dosimetric effect of the air cavity is in the range of 3%-9%. Unless a heterogeneous dose calculation algorithm is used, users should be aware of the possibility of small treatment planning dose errors for this device and make modifications to the treatment delivery, if necessary.

  16. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J. [M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States); MGS Research, Inc., Madison, Connecticut 06443 (United States)

    2010-05-15

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  17. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    International Nuclear Information System (INIS)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J.

    2010-01-01

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  18. Dose reader of dosimetric foil; Czytnik dawki folii dozymetrycznej

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.; Strzalkowski, J.; Smolko, K.

    1997-12-31

    Read out the absorbance of a dosimetric foil is accomplished by two beam spectrophotometer. Such a solution makes possible the compensation of light source instabilities and ensures higher stability of the dose reader. The error of absorbance measurement caused by the instabilities does not exceed 0.0004 A. (author). 3 refs, 3 figs.

  19. Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Wiersma, R. D.; Xing, L.

    2007-01-01

    Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the ''overshoot phenomena.'' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of ∼0.27 MU and ∼0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are

  20. Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

    International Nuclear Information System (INIS)

    Beltran, Chris; Trussell, John; Merchant, Thomas E.

    2010-01-01

    The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 ± 1.5 treatment fractions; motion data were acquired for a mean of 26 ± 6.2 fractions. The mean age was 15.6 ± 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

  1. Dosimetric control of radiotherapy treatments by Monte Carlo simulation of transmitted portal dose image

    International Nuclear Information System (INIS)

    Badel, Jean-Noel

    2009-01-01

    This research thesis addresses the dosimetric control of radiotherapy treatments by using amorphous silicon digital portal imagery. In a first part, the author reports the analysis of the dosimetric abilities of the imager (iViewGT) which is used in the radiotherapy department. The stability of the imager response on a short and on a long term has been studied. A relationship between the image grey level and the dose has been established for a reference irradiation field. The influence of irradiation parameters on the grey level variation with respect to the dose has been assessed. The obtained results show the possibility to use this system for dosimetry provided that a precise calibration is performed while taking the most influencing irradiation parameters into account, i.e. photon beam nominal energy, field size, and patient thickness. The author reports the development of a Monte Carlo simulation to model the imager response. It models the accelerator head by a generalized source point. Space and energy distributions of photons are calculated. This modelling can also be applied to the calculation of dose distribution within a patient, or to study physical interactions in the accelerator head. Then, the author explores a new approach to dose portal image prediction within the frame of an in vivo dosimetric control. He computes the image transmitted through the patient by Monte Carlo simulation, and measures the portal image of the irradiation field without the patient. Validation experiments are reported, and problems to be solved are highlighted (computation time, improvement of the collimator simulation) [fr

  2. Dosimetry through the Secondary Laboratory of Dosimetric Calibration of Mexico

    International Nuclear Information System (INIS)

    Tovar M, V.M.; Alvarez R, J.T.; Medina O, V.P.; Vergara M, F.; Anaya M, R.; Cejudo A, J.; Salinas L, B.

    2004-01-01

    In the beginnings of the sixty years an urgent necessity is presented mainly in the developing countries, of improving in important form the accuracy in the dosimetry of external faces in therapy of radiations (radiotherapy centers), mainly in the calibration of c linical dosemeters . In 1976 the International Atomic Energy Agency, (IAEA), and the World Health Organization, (WHO), they carried out a mutual agreement with regard to the establishment and operation of a net of Secondary Patron Laboratories of Dosimetry, (LSCD). The necessity to establish measure patterns in the field of the dosimetry of the ionizing radiations, is necessary, to have an accuracy but high in the dosimetry of the radiation beams in therapy which is highly dependent of the dose given to the tumor of those patient with cancer. Similar levels of accuracy are required in protection measures to the radiation with an acceptable smaller accuracy, however, when the personal dosemeters are used to determine the doses received by the individuals under work conditions, such mensurations in therapy of radiations and radiological protection will have traceability through a chain of comparisons to primary or national patterns. The traceability is necessary to assure the accuracy and acceptability of the dosimetric measures, as well as, the legal and economic implications. The traceability is also necessary in the dosimetry of high dose like in the sterilization of different products. The main function of the LSCD is to provide a service in metrology of ionizing radiations, maintaining the secondary or national patterns, which have a traceability to the International System of measures, which is based for if same in the comparison of patterns in the Primary Laboratories of Dosimetry (LPD) under the auspice of the International Office of Weights and Measure (BIPM). The secondary and national patterns in the LSCD constitute in Mexico, the national patterns of the magnitudes in the dosimetry of the

  3. An appraisal of the utility or futility of ENT consultant postal questionnaires.

    Science.gov (United States)

    Ryan, Stephen; Saunders, J; Clarke, E; Fenton, J E

    2013-03-01

    Despite an increase in ENT postal questionnaires, the quality of their methodology has been questioned (Ramphul et al. in J Laryngol Otol 119:175-178, 1). This retrospective study examined whether quality and utility of such questionnaires published since 2005 has improved. Seventeen consultant postal questionnaires published between 2005 and 2012 were reviewed. Quality of questionnaires was assessed using a 30-point score based on compliance with 15 criteria previously established to evaluate postal questionnaire study-design (Ramphul et al. in J Laryngol Otol 119:175-178, 1). Citation rates were used as an indicator of utility. The specific comments made in each citing paper was reviewed providing information on whether questionnaire findings (a) had an impact on clinical practice, (b) were the citing comments positive, (c) negative or (d) non-specific. Recurrent methodological flaws were identified in all questionnaires. The average score assigned was 44 %, versus 32 % previously reported (Ramphul et al. in J Laryngol Otol 119:175-178, 1) (P questionnaires. Citations were general non-specific referencing with no clear indication that questionnaire findings positively impacted clinical practice. In conclusion, although the quality of ENT postal questionnaire has improved since the original study (Ramphul et al. in J Laryngol Otol 119:175-178, 1), important recurring methodological flaws still exist. The poor utility, based on low citation rates, also reflects the continued deficiencies in design quality. It is recommended that authors of questionnaire-based research should ensure that guidelines for questionnaire design are adhered in order to improve the validity of findings and hence impact on clinical practice.

  4. Correistas, estafetas y líneas postales en Antioquia entre 1859 y 1919

    Directory of Open Access Journals (Sweden)

    Gustavo Adolfo Hernandez Rojas

    2016-06-01

    Full Text Available El presente artículo es uno de los resultados del proceso de investigación que se llevó a cabo en la tesis de Maestría en Historia: “El sistema de correos en Antioquia 1859-1919”. Este producto, titulado “Correistas, estafetas y líneas postales en Antioquia entre 1859 y 1919”, es una reconstrucción de carácter histórico, donde se plasmó la estructura de la institución y el funcionamiento del ramo postal de la época en el territorio antioqueño. En él, se aborda la dinámica institucional, su distribución y cobertura a través de las líneas  establecidas y las demás técnicas administrativas de control que se implementaron para su operatividad en Antioquia. El presente artículo títulado “Correistas, estafetas y líneas postales en Antioquia entre 1859 y 1919”, es una reconstrucción de carácter histórico, que trata sobre el funcionamiento y la estructura del Ramo Postal de la época, en el territorio antioqueño. En él, se aborda la dinámica institucional, su distribución y cobertura a través de las líneas establecidas y las técnicas administrativas de control que se implementaron para su operatividad. Así, las estafetas, los empleados, las líneas, los tipos de correos y los itinerarios de circulación, sonelementos que evidencian el accionar del correo como institución y servicio.

  5. Responsibility for managing musculoskeletal disorders--a cross-sectional postal survey of attitudes.

    Science.gov (United States)

    Larsson, Maria E H; Nordholm, Lena A

    2008-08-05

    Musculoskeletal disorders are a major burden on individuals, health systems and social care systems and rehabilitation efforts in these disorders are considerable. Self-care is often considered a cost effective treatment alternative owing to limited health care resources. But what are the expectations and attitudes in this question in the general population? The purpose of this study was to describe general attitudes to responsibility for the management of musculoskeletal disorders and to explore associations between attitudes and background variables. A cross-sectional, postal questionnaire survey was carried out with a random sample of a general adult Swedish population of 1770 persons. Sixty-one percent (n = 1082) responded to the questionnaire and was included for the description of general attitudes towards responsibility for the management of musculoskeletal disorders. For the further analyses of associations to background variables 683-693 individuals could be included. Attitudes were measured by the "Attitudes regarding Responsibility for Musculoskeletal disorders" (ARM) instrument, where responsibility is attributed on four dimensions; to myself, as being out of my hands, to employers or to (medical) professionals. Multiple logistic regression was used to explore associations between attitudes to musculoskeletal disorders and the background variables age, sex, education, physical activity, presence of musculoskeletal disorders, sick leave and whether the person had visited a care provider. A majority of participants had internal views, i.e. showed an attitude of taking personal responsibility for musculoskeletal disorders, and did not place responsibility for the management out of their own hands or to employers. However, attributing shared responsibility between self and medical professionals was also found. The main associations found between attitude towards responsibility for musculoskeletal disorders and investigated background variables were that

  6. Responsibility for managing musculoskeletal disorders – A cross-sectional postal survey of attitudes

    Directory of Open Access Journals (Sweden)

    Larsson Maria EH

    2008-08-01

    Full Text Available Abstract Background Musculoskeletal disorders are a major burden on individuals, health systems and social care systems and rehabilitation efforts in these disorders are considerable. Self-care is often considered a cost effective treatment alternative owing to limited health care resources. But what are the expectations and attitudes in this question in the general population? The purpose of this study was to describe general attitudes to responsibility for the management of musculoskeletal disorders and to explore associations between attitudes and background variables. Methods A cross-sectional, postal questionnaire survey was carried out with a random sample of a general adult Swedish population of 1770 persons. Sixty-one percent (n = 1082 responded to the questionnaire and was included for the description of general attitudes towards responsibility for the management of musculoskeletal disorders. For the further analyses of associations to background variables 683–693 individuals could be included. Attitudes were measured by the "Attitudes regarding Responsibility for Musculoskeletal disorders" (ARM instrument, where responsibility is attributed on four dimensions; to myself, as being out of my hands, to employers or to (medical professionals. Multiple logistic regression was used to explore associations between attitudes to musculoskeletal disorders and the background variables age, sex, education, physical activity, presence of musculoskeletal disorders, sick leave and whether the person had visited a care provider. Results A majority of participants had internal views, i.e. showed an attitude of taking personal responsibility for musculoskeletal disorders, and did not place responsibility for the management out of their own hands or to employers. However, attributing shared responsibility between self and medical professionals was also found. The main associations found between attitude towards responsibility for musculoskeletal

  7. SU-G-TeP3-11: Radiobiological-Cum-Dosimetric Quality Assurance of Complex Radiotherapy Plans

    Energy Technology Data Exchange (ETDEWEB)

    Paudel, N; Narayanasamy, G; Zhang, X; Penagaricano, J; Morrill, S [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Mavroidis, P [University North Carolina, Chapel Hill, NC (United States); Pyakuryal, A [National Cancer Institute, Rockville, MD (United States); Han, E [UT MD Anderson Cancer Center, Houston, TX (United States); Liang, X [University of Florida Health Proton Therapy Institute, Jacksonville, FL (United States); Kim, D [Kyung Hee University Hospital, Seol (Korea, Republic of)

    2016-06-15

    Purpose: Dosimetric gamma-analysis used for QA of complex radiotherapy plans tests the dosimetric equivalence of a delivered plan with the treatment planning system (TPS) optimized plan. It does not examine whether a dosimetric difference results in any radiobiological difference. This study introduces a method to test the radiobiological and dosimetric equivalence between a delivered and the TPS optimized plan. Methods: Six head and neck and seven lung cancer VMAT or IMRT plans optimized for patient treatment were calculated and delivered to an ArcCheck phantom. ArcCheck measured dose distributions were compared with the TPS calculated dose distributions using a 2-D gamma-analysis. Dose volume histograms (DVHs) for various patient structures were obtained by using measured data in 3DVH software and compared against the TPS calculated DVHs using 3-D gamma analysis. DVH data were used in the Poisson model to calculate tumor control probability (TCP) for the treatment targets and in the sigmoid dose response model to calculate normal tissue complication probability (NTCP) for the normal structures. Results: Two-D and three-D gamma passing rates among six H&N patient plans differed by 0 to 2.7% and among seven lung plans by 0.1 to 4.5%. Average ± SD TCPs based on measurement and TPS were 0.665±0.018 and 0.674±0.044 for H&N, and 0.791±0.027 and 0.733±0.031 for lung plans, respectively. Differences in NTCPs were usually negligible. The differences in dosimetric results, TCPs and NTCPs were insignificant. Conclusion: The 2-D and 3-D gamma-analysis based agreement between measured and planned dose distributions may indicate their dosimetric equivalence. Small and insignificant differences in TCPs and NTCPs based on measured and planned dose distributions indicate the radiobiological equivalence between the measured and optimized plans. However, patient plans showing larger differences between 2-D and 3-D gamma-analysis can help us make a more definite conclusion

  8. SU-F-E-06: Dosimetric Characterization of Small Photons Beams of a Novel Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Almonte, A; Polanco, G; Sanchez, E [Instituto Oncologico Dr. Heriberto Pieter, Santo Domingo, Distrito Nacional (Dominican Republic)

    2016-06-15

    Purpose: The aim of the present contribution was to measure the main dosimetric quantities of small fields produced by UNIQUE and evaluate its matching with the corresponding dosimetric data of one 21EX conventional linear accelerator (Varian) in operation at the same center. The second step was to evaluate comparative performance of the EDGE diode detector and the PinPoint micro-ionization chamber for dosimetry of small fields. Methods: UNIQUE is configured with MLC (120 leaves with 0.5 cm leaf width) and a single low photon energy of 6 MV. Beam data were measured with scanning EDGE diode detector (volume of 0.019 mm{sup 3}), a PinPoint micro-ionization chamber (PTW) and for larger fields (≥ 4×4cm{sup 2}) a PTW Semi flex chamber (0.125 cm{sup 3}) was used. The scanning system used was the 3D cylindrical tank manufactured by Sun Nuclear, Inc. The measurement of PDD and profiles were done at 100 cm SSD and 1.5 depth; the relative output factors were measured at 10 cm depth. Results: PDD and the profile data showed less than 1% variation between the two linear accelerators for fields size between 2×2 cm{sup 2} and 5×5cm{sup 2}. Output factor differences was less than 1% for field sizes between 3×3 cm{sup 2} and 10×10 cm{sup 2} and less of 1.5 % for fields of 1.5×1.5 cm{sup 2} and 2×2 cm{sup 2} respectively. The dmax value of the EDGE diode detector, measured from the PDD, was 8.347 mm for 0.5×0,5cm{sup 2} for UNIQUE. The performance of EDGE diode detector was comparable for all measurements in small fields. Conclusion: UNIQUE linear accelerator show similar dosimetrics characteristics as conventional 21EX Varian linear accelerator for small, medium and large field sizes.EDGE detector show good performance by measuring dosimetrics quantities in small fields typically used in IMRT and radiosurgery treatments.

  9. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-01-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al 2 O 3 :C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al 2 O 3 :C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O 3 :C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  10. Conceptual source design and dosimetric feasibility study for intravascular treatment: a proposal for intensity modulated brachytherapy

    International Nuclear Information System (INIS)

    Kim, Si Yong; Han, Eun Young; Palta, Jatinder R.; Ha, Sung W.

    2003-01-01

    To propose a conceptual design of a novel source for intensity modulated brachytherapy. The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a 90 Sr/Y Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quarter of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. The preliminary hypothetical simulation and optimization results demonstrated the 87% difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7% by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter

  11. Dosimetric properties of dysprosium doped calcium magnesium borate glass subjected to Co-60 gamma ray

    Energy Technology Data Exchange (ETDEWEB)

    Omar, R. S., E-mail: ratnasuffhiyanni@gmail.com; Wagiran, H., E-mail: husin@utm.my; Saeed, M. A. [Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia)

    2016-01-22

    Thermoluminescence (TL) dosimetric properties of dysprosium doped calcium magnesium borate (CMB:Dy) glass are presented. This study is deemed to understand the application of calcium as the modifier in magnesium borate glass with the presence of dysprosium as the activator to be performed as TL dosimeter (TLD). The study provides fundamental knowledge of a glass system that may lead to perform new TL glass dosimetry application in future research. Calcium magnesium borate glass systems of (70-y) B{sub 2}O{sub 3} − 20 CaO – 10 MgO-(y) Dy{sub 2}O{sub 3} with 0.05  mol % ≤ y ≤ 0.7  mol % of dyprosium were prepared by melt-quenching technique. The amorphous structure and TL properties of the prepared samples were determined using powder X-ray diffraction (XRD) and TL reader; model Harshaw 4500 respectively. The samples were irradiated to Co-60 gamma source at a dose of 50 Gy. Dosimetric properties such as annealing procedure, time temperature profile (TTP) setting, optimization of Dy{sub 2}O{sub 3} concentration of 0.5 mol % were determined for thermoluminescence dosimeter (TLD) reader used.

  12. Conceptual source design and dosimetric feasibility study for intravascular treatment: a proposal for intensity modulated brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Si Yong; Han, Eun Young; Palta, Jatinder R. [College of Medicine, Florida Univ., Florida (United States); Ha, Sung W. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2003-06-01

    To propose a conceptual design of a novel source for intensity modulated brachytherapy. The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a {sub 90}Sr/Y Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quarter of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. The preliminary hypothetical simulation and optimization results demonstrated the 87% difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7% by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter.

  13. Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

    International Nuclear Information System (INIS)

    Staton, Robert J.; Langen, Katja M.; Kupelian, Patrick A.; Meeks, Sanford L.

    2009-01-01

    In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about ±2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude (±2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of ±7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D 50 of organs at risk, the D 95 for planning target volumes (PTVs), and the local dose difference were used to

  14. Benchmarking Dosimetric Quality Assessment of Prostate Intensity-Modulated Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Senthi, Sashendra, E-mail: sasha.senthi@petermac.org [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Gill, Suki S. [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Haworth, Annette; Kron, Tomas; Cramb, Jim [Department of Physical Sciences, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Rolfo, Aldo [Radiation Therapy Services, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Thomas, Jessica [Biostatistics and Clinical Trials, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Duchesne, Gillian M. [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Hamilton, Christopher H.; Joon, Daryl Lim [Radiation Oncology Department, Austin Repatriation Hospital, Heidelberg, VIC (Australia); Bowden, Patrick [Radiation Oncology Department, Tattersall' s Cancer Center, East Melbourne, VIC (Australia); Foroudi, Farshad [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia)

    2012-02-01

    Purpose: To benchmark the dosimetric quality assessment of prostate intensity-modulated radiotherapy and determine whether the quality is influenced by disease or treatment factors. Patients and Methods: We retrospectively analyzed the data from 155 consecutive men treated radically for prostate cancer using intensity-modulated radiotherapy to 78 Gy between January 2007 and March 2009 across six radiotherapy treatment centers. The plan quality was determined by the measures of coverage, homogeneity, and conformity. Tumor coverage was measured using the planning target volume (PTV) receiving 95% and 100% of the prescribed dose (V{sub 95%} and V{sub 100%}, respectively) and the clinical target volume (CTV) receiving 95% and 100% of the prescribed dose. Homogeneity was measured using the sigma index of the PTV and CTV. Conformity was measured using the lesion coverage factor, healthy tissue conformity index, and the conformity number. Multivariate regression models were created to determine the relationship between these and T stage, risk status, androgen deprivation therapy use, treatment center, planning system, and treatment date. Results: The largest discriminatory measurements of coverage, homogeneity, and conformity were the PTV V{sub 95%}, PTV sigma index, and conformity number. The mean PTV V{sub 95%} was 92.5% (95% confidence interval, 91.3-93.7%). The mean PTV sigma index was 2.10 Gy (95% confidence interval, 1.90-2.20). The mean conformity number was 0.78 (95% confidence interval, 0.76-0.79). The treatment center independently influenced the coverage, homogeneity, and conformity (all p < .0001). The planning system independently influenced homogeneity (p = .038) and conformity (p = .021). The treatment date independently influenced the PTV V{sub 95%} only, with it being better at the start (p = .013). Risk status, T stage, and the use of androgen deprivation therapy did not influence any aspect of plan quality. Conclusion: Our study has benchmarked measures

  15. Computational model for dosimetric purposes in dental procedures

    International Nuclear Information System (INIS)

    Kawamoto, Renato H.; Campos, Tarcisio R.

    2013-01-01

    This study aims to develop a computational model for dosimetric purposes the oral region, based on computational tools SISCODES and MCNP-5, to predict deterministic effects and minimize stochastic effects caused by ionizing radiation by radiodiagnosis. Based on a set of digital information provided by computed tomography, three-dimensional voxel model was created, and its tissues represented. The model was exported to the MCNP code. In association with SICODES, we used the Monte Carlo N-Particle Transport Code (MCNP-5) method to play the corresponding interaction of nuclear particles with human tissues statistical process. The study will serve as a source of data for dosimetric studies in the oral region, providing deterministic effect and minimize the stochastic effect of ionizing radiation

  16. Radiometric and dosimetric characteristics of HgI2 detectors

    International Nuclear Information System (INIS)

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-01-01

    The characteristics of HgI 2 detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV

  17. Dosimetric considerations and radiation protection of patients in interventional cardiology

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Arandjic, D.; Kosutic, D.; Loncar, B.

    2009-01-01

    The paper summarizes results of measurements of relevant dosimetric quantities in interventional cardiology. Dosimetric data were collected for 117 coronary angiography (CA) procedures, 69 percutaneous coronary interventions (PCI) and 41 combined procedures (CA+PCI), taking into account two quantities: air kerma area product (KAP) d air kerma in international reference point (K IRP ). Mean KAP values were 78 Gy·cm 2 , 113 Gy·cm 2 and 141 Gy·cm 2 for CA, PCI i CA+PCI, respectively. Corresponding mean K IRP values were 1.2 Gy, 1.8 Gy and 2.2 Gy. With respect to high dose values, risk for stochastic effects and tissue reactions, dose management methods were proposed. (author) [sr

  18. Dosimetric quality control in radiotherapy using TLD methodology

    International Nuclear Information System (INIS)

    Saravi, M.C.; Kessler, C.; Alvarez, P.E.; Feld, D.B.

    2002-01-01

    In the frame of the IAEA Co-ordinated Research Project 'Development of a Quality Assurance Program for Radiation Therapy Dosimetry in Developing Countries' a Dosimetric Quality Control Group was set up in Argentina in 1996, to develop a program in order to improve radiotherapy in the country. Nowadays, this Group, briefly called External Audit Group (EAG), is composed by the national Secondary Standard Dosimetry Laboratory (SSDL), which has the responsibility for dose determinations, traceability to international dosimetry chain and TLD measurements, and two Medical Physicists from CNEA who are working at the Oncology Hospital 'Marie Curie' in Buenos Aires. The present paper reports the activities performed by the EAG with external high energy photon beams in reference conditions and the results of two pilot studies on cobalt 60 beams in non-reference conditions. The first step of the program was to update the existing data base about the radiotherapy centres operating in the country. A form was sent to each of them in order to obtain basic information about their staff, number and type of treatment machines, brachytherapy sources, measuring devices, beam calibration, treatment planning system, simulator and other relevant data. 90 radiotherapy centres were registered in the EAG data base. Forms were completed by 75/90 centres. There are nowadays 69 cobalt 60 units and 42 LINACs operating in the country (18/42 LINACs producing high energy X ray and electron beams). EAG deals with measurements performed with mailed TLD irradiated at radiotherapy centres. Internal quality control on our TLD system is made during each audit by means of reference capsules irradiated by IAEA; external controls consist in blind tests performed by IAEA once a year. The correction factor, K en , determined at our SSDL for high energy X-rays was checked with the collaboration of IAEA and Prague National Radiation Protection Institute (PNRPI) by means of a blind test. Results for 4 MV, 6 MV

  19. Benchmarking Dosimetric Quality Assessment of Prostate Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Senthi, Sashendra; Gill, Suki S.; Haworth, Annette; Kron, Tomas; Cramb, Jim; Rolfo, Aldo; Thomas, Jessica; Duchesne, Gillian M.; Hamilton, Christopher H.; Joon, Daryl Lim; Bowden, Patrick; Foroudi, Farshad

    2012-01-01

    Purpose: To benchmark the dosimetric quality assessment of prostate intensity-modulated radiotherapy and determine whether the quality is influenced by disease or treatment factors. Patients and Methods: We retrospectively analyzed the data from 155 consecutive men treated radically for prostate cancer using intensity-modulated radiotherapy to 78 Gy between January 2007 and March 2009 across six radiotherapy treatment centers. The plan quality was determined by the measures of coverage, homogeneity, and conformity. Tumor coverage was measured using the planning target volume (PTV) receiving 95% and 100% of the prescribed dose (V 95% and V 100% , respectively) and the clinical target volume (CTV) receiving 95% and 100% of the prescribed dose. Homogeneity was measured using the sigma index of the PTV and CTV. Conformity was measured using the lesion coverage factor, healthy tissue conformity index, and the conformity number. Multivariate regression models were created to determine the relationship between these and T stage, risk status, androgen deprivation therapy use, treatment center, planning system, and treatment date. Results: The largest discriminatory measurements of coverage, homogeneity, and conformity were the PTV V 95% , PTV sigma index, and conformity number. The mean PTV V 95% was 92.5% (95% confidence interval, 91.3–93.7%). The mean PTV sigma index was 2.10 Gy (95% confidence interval, 1.90–2.20). The mean conformity number was 0.78 (95% confidence interval, 0.76–0.79). The treatment center independently influenced the coverage, homogeneity, and conformity (all p 95% only, with it being better at the start (p = .013). Risk status, T stage, and the use of androgen deprivation therapy did not influence any aspect of plan quality. Conclusion: Our study has benchmarked measures of coverage, homogeneity, and conformity for the treatment of prostate cancer using IMRT. The differences seen between centers and planning systems and the coverage

  20. Influence of lucite phantoms on calibration of dosimetric pens

    International Nuclear Information System (INIS)

    Oliveira, E.C.; Xavier, M.; Caldas, L.E.V.

    1992-01-01

    Dosimetrical pens were studied for the answer repetition and were tested in gamma radiation fields ( 60 Co and 137 Cs) in air and in front of a lucite phantom, obtaining a backscattering contribution. The medium backscattering factors were 1,053 and 1,108 for respectively 60 Co and 137 Cs. The pens were placed behind the phantom for verifying the radiation attenuation. (C.G.C.)

  1. Intraoperative real-time planned conformal prostate brachytherapy: Post-implantation dosimetric outcome and clinical implications

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Yamada, Yoshiya; Cohen, Gil'ad N.; Sharma, Neha; Shippy, Alison M.; Fridman, David; Zaider, Marco

    2007-01-01

    Purpose: To report the dosimetric outcome of patients with clinically localized prostate cancer treated with I-125 permanent implantation using an intraoperative real-time conformal planning technique. Methods and materials: Five hundred and sixty-two patients with prostate cancer were treated with I-125 permanent interstitial implantation using a transrectal ultrasound-guided approach. Real-time intraoperative treatment planning software that incorporates inverse planning optimization was used. Dose-volume constraints for this inverse-planning system included: prostate V100 ≥95%, maximal urethral dose ≤120%, and average rectal dose 3 of the rectum was exposed to the prescription dose, the incidence of late grade 2 toxicity rectal toxicity was 9% compared to 4% for smaller volumes of the rectum exposed to similar doses (p = 0.003). No dosimetric parameter in these patients with tight dose confines for the urethra influenced acute or late urinary toxicity. Conclusion: Real-time intraoperative planning was associated with a 90% consistency of achieving the planned intraoperative dose constraints for target coverage and maintaining planned urethral and rectal constraints in a high percentage of implants. Rectal volumes of ≥2.5 cm 3 exposed to the prescription doses were associated with an increased incidence of grade 2 rectal bleeding. Further enhancements in imaging guidance for optimal seed deposition are needed to guarantee optimal dose distribution for all patients. Whether such improvements lead to further reduction in acute and late morbidities associated with therapy requires further study

  2. Gamma dosimetric parameters in some skeletal muscle relaxants

    Science.gov (United States)

    Manjunatha, H. C.

    2017-09-01

    We have studied the attenuation of gamma radiation of energy ranging from 84 keV to 1330 keV (^{170}Tm, ^{22}Na,^{137}Cs, and ^{60}Co) in some commonly used skeletal muscle relaxants such as tubocurarine chloride, gallamine triethiodide, pancuronium bromide, suxamethonium bromide and mephenesin. The mass attenuation coefficient is measured from the attenuation experiment. In the present work, we have also proposed the direct relation between mass attenuation coefficient (μ /ρ ) and mass energy absorption coefficient (μ _{en}/ρ ) based on the nonlinear fitting procedure. The gamma dosimetric parameters such as mass energy absorption coefficient (μ _{en}/ρ ), effective atomic number (Z_{eff}), effective electron density (N_{el}), specific γ-ray constant, air kerma strength and dose rate are evaluated from the measured mass attentuation coefficient. These measured gamma dosimetric parameters are compared with the theoretical values. The measured values agree with the theoretical values. The studied gamma dosimetric values for the relaxants are useful in medical physics and radiation medicine.

  3. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    Energy Technology Data Exchange (ETDEWEB)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D [OH State University, Columbus, OH (United States)

    2015-06-15

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.

  4. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    International Nuclear Information System (INIS)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D

    2015-01-01

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis

  5. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Crowe, Scott B [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia); Kairn, Tanya [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia); Premion, Wesley Medical Centre, Brisbane, Queensland (Australia); Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T [Premion, Wesley Medical Centre, Brisbane, Queensland (Australia); Kenny, John [Australian Clinical Dosimetry Services, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Victoria (Australia); Langton, Christian M; Trapp, Jamie V [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia)

    2013-12-15

    This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

  6. Dosimetric properties of the 'Pille' portable, wide dose range TLD reader

    International Nuclear Information System (INIS)

    Szabo, P.P.; Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.

    1986-01-01

    The dosimetric properties of a portable TLD reader are described. The TLD system named 'Pille' or 'moth' consists of a lightweight battery-operated portable TLD reader and its CaSO 4 :Dy bulb dosemeters. The reproducibility of the TLD system at constant temperature was found to be better than + -2%, and the mean time between failures exceeded 5 years. The dose range of the system is wide, covering more than 6 orders of magnitude, from 5 μGy to 10 Gy. The energy dependence of the CaSO 4 :Dy bulb dosemeters is less than + - 20% above 100 keV in the energy compensation capsules. Without additional annealing, the bulb dosemeters can be re-used at least 100 times, which is an important aspect during in situ measurements. (author)

  7. Development of a dosimetric system for the quality control of breast cancer treatments; Desenvolvimento de um sistema dosimetrico para o controle de qualidade nos tratamentos de cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Roberio C.; Crispim, Verginia R., E-mail: rchaves@nuclear.ufrj.br, E-mail: verginia@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/lUFRJ), RJ (Brazil). Programa de Pos-Graduacao em Engenharia Nuclear; Rosa, Luiz A.R. da, E-mail: Irosa@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Rio de Janeiro, RJ (Brazil); Santos, Delano B.V., E-mail: delano@inca.gov.br [Instituto Nacional do Cancer (INCA/MS), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    A system for evaluating the values of absorbed dose in breast teletherapy was developed, using thermoluminescent dosimeters (TLD-100), to compare them to those provided by Therapy planning system. A breast phantom was made to distribute the dosimeters TL shaped chip in breast volume and irradiate it under the same conditions of planning. Three different techniques of teletherapy were considered: one with irradiation from a therapy unit of {sup 60}Co and two with an X-ray beam coming from a 6 MV linear accelerator. Doses measures allowed checking that the performance of the quality control system used in breast cancer treatment is appropriate, since the planned doses differed about 1.5% of the responses provided by TL dosimeters.

  8. The role of the Secondary Laboratory of Dosimetric calibration in the implementation of the dosimetric magnitudes with radiological protection aims

    International Nuclear Information System (INIS)

    Perez Medina O, V.; Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    It is very well-known the paper of the net of secondary laboratories of dosimetric calibration of the OAS in the dissemination of the traceability of the dosimetric magnitudes: kerma in air and absorbed dose in water, to the radiotherapy departments, given the high accuracy and precision that require the radiotherapy treatments. However the LSCD has other important areas at least for the development, implementation and evaluation of dosimetric magnitudes denominated operative magnitudes with ends of radiological protection: environmental equivalent dose H*(10), directional equivalent dose H'(0.07) and personal equivalent dose Hp. In the case of radiological protection the LSCD-ININ has been implementing the infrastructure to give service of personal dosimetry for photons and beta particles in terms of the operative magnitudes. For photons: X and gamma rays, it account with a secondary pattern camera PTW T34035 gauged in H * and Hp in the primary laboratory of Germany PTB. For the case of beta radiation its account with an extrapolation camera PTW 23392 with a secondary pattern kit of sources of the type I, gauged in terms of H'(0.07) in the PTB. (Author)

  9. Lutero y el luteranismo: El buzón postal Martín Lutero

    OpenAIRE

    Marco Ornelas

    2014-01-01

    Este artículo explora la idea de que la comunicación social opera de manera acoplada con las conciencias de los seres humanos – pero no es generada por ellas – , y utiliza como ejemplo al reformador alemán Martín Lutero. El traslape de operaciones de la conciencia y de operaciones comunicativas – interpenetración – se hace posible por la distinción persona/actor, que se actualiza en la comunicación mediante esquemas (el esquema per sona y el esquema actor), el llamado buzón postal Martín Lute...

  10. Optimización de las redes de distribución del Servicio Postal Universal

    OpenAIRE

    Vera López, José Antonio

    2017-01-01

    La necesidad cotidiana de los ciudadanos de comunicarse, con el fin de realizar diferentes actividades de cualquier naturaleza, se ha visto afectada en gran medida por los cambios recientemente producidos. Las ventajas generadas por la inclusión de las nuevas tecnologías como modo de comunicación, y la proliferación de su uso entre la ciudadanía, son innumerables y se extienden tanto en el ámbito personal como en el privado. En la actualidad los servicios postales están sufriendo ...

  11. SU-F-T-240: EPID-Based Quality Assurance for Dosimetric Credentialing

    Energy Technology Data Exchange (ETDEWEB)

    Miri, N [University of Newcastle, Newcastle, NSW (Australia); Lehmann, J [Calvary Mater Newcastle, Newcastle, NSW (Australia); Vial, P [Liverpool Hospital, Sydney, NSW (Australia); Greer, P [Calvary Mater Newcastle, Newcastle, NSW (Australia); University of Newcastle, Newcastle, NSW (Australia)

    2016-06-15

    Purpose: We propose a novel dosimetric audit method for clinical trials using EPID measurements at each center and a standardized EPID to dose conversion algorithm. The aim of this work is to investigate the applicability of the EPID method to different linear accelerator, EPID and treatment planning system (TPS) combinations. Methods: Combination of delivery and planning systems were three Varian linacs including one Pinnacle and two Eclipse TPS and, two ELEKTA linacs including one Pinnacle and one Monaco TPS. All Varian linacs had the same EPID structure and similarly for the ELEKTA linacs. Initially, dose response of the EPIDs was investigated by acquiring integrated pixel value (IPV) of the central area of 10 cm2 images versus MUs, 5-400 MU. Then, the EPID to dose conversion was investigated for different system combinations. Square field size images, 2, 3, 4, 6, 10, 15, 20, 25 cm2 acquired by all systems were converted to dose at isocenter of a virtual flat phantom then the dose was compared to the corresponding TPS dose. Results: All EPIDs showed a relatively linear behavior versus MU except at low MUs which showed irregularities probably due to initial inaccuracies of irradiation. Furthermore, for all the EPID models, the model predicted TPS dose with a mean dose difference percentage of 1.3. However the model showed a few inaccuracies for ELEKTA EPID images at field sizes larger than 20 cm2. Conclusion: The EPIDs demonstrated similar behavior versus MU and the model was relatively accurate for all the systems. Therefore, the model could be employed as a global dosimetric method to audit clinical trials. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

  12. Development of a computational system based in the code GEANT4 for dosimetric evaluation in radiotherapy; Desenvolvimento de um sistema computacional baseado no Codigo GEANT4 para avaliacoes dosimetricas em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Alex Cristovao Holanda de

    2016-10-01

    The incidence of cancer has grown in Brazil, as well as around the world, following the change in the age profile of the population. One of the most important techniques and commonly used in cancer treatment is radiotherapy. Around 60% of new cases of cancer use radiation in at least one phase of treatment. The most used equipment for radiotherapy is a linear accelerator (Linac) which produces electron or X-ray beams in energy range from 5 to 30 MeV. The most appropriate way to irradiate a patient is determined during treatment planning. Currently, treatment planning system (TPS) is the main and the most important tool in the process of planning for radiotherapy. The main objective of this work is to develop a computational system based on the MC code Geant4 for dose evaluations in photon beam radiotherapy. In addition to treatment planning, these dose evaluations can be performed for research and quality control of equipment and TPSs. The computer system, called Quimera, consists of a graphical user interface (qGUI) and three MC applications (qLinacs, qMATphantoms and qNCTphantoms). The qGUI has the function of interface for the MC applications, by creating or editing the input files, running simulations and analyzing the results. The qLinacs is used for modeling and generation of Linac beams (phase space). The qMATphantoms and qNCTphantoms are used for dose calculations in virtual models of physical phantoms and computed tomography (CT) images, respectively. From manufacturer's data, models of a Varian Linac photon beam and a Varian multileaf collimator (MLC) were simulated in the qLinacs. The Linac and MLC modelling were validated using experimental data. qMATphamtoms and qNCTphantoms were validated using IAEA phase spaces. In this first version, the Quimera can be used for research, radiotherapy planning of simple treatments and quality control in photon beam radiotherapy. The MC applications work independent of the qGUI and the qGUI can be used for

  13. Implementation of a gel dosimeter for dosimetric verification of treatments with RapidArcTM

    International Nuclear Information System (INIS)

    Cortes, H.; Vasquez, J.; Plazas, M.

    2014-08-01

    The gel dosimetry represents advantages on other dosimetric systems for its potential of analyzing information in third dimension (3D). This work seeks to find another alternative for the verification of treatments of high complexity like the RapidArc TM . A gel type Magic was prepared and characterized, which was irradiated with base in a plan of RapidArc TM calculated in the Treatment Planning System (Tps) Eclipse, using the Anisotropic Analytic Algorithm (Aaa) for a beam with an acceleration potential of 6 MV. The dosimeter was characterized using Magnetic Resonance Images starting from the correlation between the T2 and the dose. The dose distribution curves were analyzed in second dimension (2D) using the program Omni Pro-I mrT and were compared with the curves obtained for the Tps under the approach gamma 2D. The comparison showed that the Gel represents a valid option inside the acceptable ranges for Quality Assurance in radiotherapy. (Author)

  14. Dosimetric properties of a radiochromic gel detector for diagnostic X-rays

    International Nuclear Information System (INIS)

    Bero, M.A.

    2007-01-01

    The gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. The Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different responses for low- and medium-energy X-rays in comparison with high-energy γ-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response, other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100-300 kV. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0-20 Gy

  15. 10 x 15. Las tarjetas postales como huellas de las prácticas de los turistas

    Directory of Open Access Journals (Sweden)

    Carla Lois

    2017-01-01

    Full Text Available Las postales han sido objeto de análisis que han puesto el acento en diferentes cuestiones. De manera destacada puede reconocerse una tradición que ha analizado las imágenes que componen las postales para conocer cómo se retratan los destinos turísticos. Otros abordajes han complementado estos análisis señalando la condición de objeto complejo: un objeto que se elige, se adquiere, se escribe, se envía (e incluso se conserva como parte de la experiencia turística. Se ha sugerido que la postal presenta una imagen estandarizada (la que se encuentra en el verso y un espacio para la escritura del turista (en el reverso marcada por la subjetividad. Este artículo busca cuestionar esa supuesta dicotomía entre imagen estereotipada y anónima versus texto subjetivo y personal a partir de una revisión histórica de la postal como objeto (sus modos de uso, sus formatos, sus usuarios y proponer un análisis cualitativo de las postales que entrelace el verso y el reverso como fuente para indagar sobre las prácticas turísticas desde el punto de vista desde el propio turista.

  16. 75 FR 56471 - Revisions to the Requirements for Authority To Manufacture and Distribute Postage Evidencing Systems

    Science.gov (United States)

    2010-09-16

    ... evidencing systems (``Company or Companies'') engage a qualified, independent audit firm to perform an... Distribute Postage Evidencing Systems AGENCY: Postal Service TM . ACTION: Final rule. SUMMARY: The Postal..., at 202-268-7613. SUPPLEMENTARY INFORMATION: Postage Evidencing Systems are devices or systems of...

  17. Monopolization versus sustainable growth – the case of postal services market in Poland

    Directory of Open Access Journals (Sweden)

    Tomasz Bernat

    2013-11-01

    Full Text Available Economies of the European Union are evolving towards the competitive development along with sustainable development. For many years, these have been the key elements of the unions strategic goals. This indicates, actions in order to achieve them on particular markets, especially on monopolized markets. These includes the postal services market. This raises the question, whether the monopolization of the area-at least a certain segment, has an impact on the biggest player on the market when taking or not taking action regarding the sustainable growth? Three hypotheses and their verification give the answer to this question. The hipotheses are as follow: the Poczta Polska SA is operator which ratify the Universal Postal Convention, therefore, pro-environmental and pro-social goals should be part of their actions; Operators involved in environmental and social activities take official strategy CSR (Corporate Social Responsibility and officially announce it publicly, for instance, on their own websites; actions speak for themselves - the entity involved in the particular area will be actively participate in it, so that its operation will be known to the public. As a research method, have been used case study and analysis of the literature. The paper highlights both academic as well as managerial implications.

  18. Results of dosimetric measurements in space missions

    International Nuclear Information System (INIS)

    Reitz, G.; Strauch, K.; Beaujean, R.; Kopp, J.; Leicher, M.; Heilmann, C.

    1997-01-01

    Detector packages consisting of thermoluminescence detectors (TLDs), nuclear emulsions and plastic nuclear track detectors were exposed in different locations inside spacecraft. The detector systems, which supplement each other in their registration characteristics, allow the recording of biologically relevant portions of the radiation field independently. Results are presented and compared with calculations. Dose equivalents for the astronauts have been calculated based on the measurements; they lie between 190 μSv.d -1 and 860 μSv.d -1 . (author)

  19. Radioecological and dosimetric consequences of the Chernobyl accident in France

    International Nuclear Information System (INIS)

    Renaud, Ph.; Beaugelin, K.; Maubert, H.; Ledenvic, Ph.

    1997-11-01

    This study has as objective a survey of the radioecological and dosimetric consequences of the Chernobyl accident in France, as well as a prognosis for the years to come. It was requested by the Direction of Nuclear Installation Safety (DSIN) in relation to different organisms which effected measurements after this accident. It is based on the use of combined results of measurements and modelling by means of the code ASTRAL developed at IPSN. Various measurements obtained from five authorities and institutions, were made available, such as: activity of air and water, soil, processed food, agricultural and natural products. However, to achieve the survey still a modelling is needed. ASTRAL is a code for evaluating the ecological consequences of an accident. It allows establishing the correspondence between the soil Remnant Surface Activities (RSA, in Bq.m -2 ), the activity concentration of the agricultural production and the individual and collective doses resulting from external and internal exposures (due to inhalation and ingestion of contaminated nurture). The results of principal synthesis documents on the Chernobyl accident and its consequences were also used. The report is structured in nine sections, as follows: 1.Introduction; 2.Objective and methodology; 3.Characterization of radioactive depositions; 4;Remnant surface activities; 5.Contamination of agricultural products and foods; 6.Contamination of natural, semi-natural products and of drinking water; 7.Dosimetric evaluations; 8.Proposals for the environmental surveillance; 9.Conclusion. Finally, after ten years, one concludes that at present the dosimetric consequences of the Chernobyl accident in France were rather limited. For the period 1986-2046 the average individual effective dose estimated for the most struck zone is lower than 1500 μSv, which represents almost 1% of the average natural exposure for the same period. At present, the cesium 137 levels are at often inferior to those recorded before

  20. Monte Carlo generation of dosimetric parameters for eye plaque dosimetry

    International Nuclear Information System (INIS)

    Cutajar, D.L.; Green, J.A.; Guatelli, S.; Rosenfeld, A.B.

    2010-01-01

    Full text: The Centre for Medical Radiation Physics have undertaken the dcvelopment of a quality assurance tool, using silicon pixelated detectors, for the calibration of eye plaques prior to insertion. Dosimetric software to correlate the measured and predicted dose rates has been constructed. The dosimetric parameters within the software, for both 1-125 and Ru-I 06 based eye plaques, were optimised using the Geant4 Monte Carlo toolkit. Methods For 1-125 based plaques, an novel application was developed to generate TG-43 parameters for any seed input. TG-43 parameters were generated for an Oncura model 6711 seed, with data points every millimetre up to 25 mm in the radial direction, and every 5 degrees in polar angle, and correlated to published data. For the Ru106 based plaques, an application was developed to generate dose rates about a Bebig model CCD plaque. Toroids were used to score the deposited dose, taking advantage of the cylindrical symmetry of the plaque, with radii in millimetre increments up to 25 mm, and depth from the plaque surface in millimetre increments up to 25 mm. Results TheTG43 parameters generated for the 6711 seed correlate well with published TG43 data at the given intervals, with radial dose function within 3%, and anisotropy function within 5% for angles greater than 30 degrees. The Ru-l 06 plaque data correlated well with the Bebig protocol of measurement. Conclusion Geant4 is a useful Monte Carlo tool for the generation of dosimetric data for eye plaque dosimetry. which may improve the quality assurance of eye plaque treatment. (author)