WorldWideScience

Sample records for positron-emission tomography pet-ct

  1. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  2. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina

    2016-01-01

    PURPOSE: To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence....... PATIENTS AND METHODS: One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four...

  3. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  4. [(18) F]fluoromethylcholine (FCH) positron emission tomography/computed tomography (PET/CT) for lymph node staging of prostate cancer

    DEFF Research Database (Denmark)

    Poulsen, Mads H; Bouchelouche, Kirsten; Høilund-Carlsen, Poul F

    2012-01-01

    recurrence. Therefore, one may question whether surgical lymph node dissection (LND) is sufficiently reliable for staging of these patients. Several imaging methods for primary LN staging of patients with prostate cancer have been tested. Acceptable detection rates have not been achieved by CT or MRI...... this procedure. However, we did detect several bone metastases with [(18) F]FCH PET/CT that the normal bone scans had missed, and this might be worth pursuing. OBJECTIVES: •  To assess the value of [(18) F]fluoromethylcholine (FCH) positron emission tomography/computed tomography (PET/CT) for lymph node (LN...

  5. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  6. Positron Emission Tomography (PET) and breast cancer in clinical practice

    International Nuclear Information System (INIS)

    Lavayssiere, Robert; Cabee, Anne-Elizabeth; Filmont, Jean-Emmanuel

    2009-01-01

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005

  7. Positron Emission Tomography (PET) and breast cancer in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Lavayssiere, Robert [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France)], E-mail: cab.lav@wanadoo.fr; Cabee, Anne-Elizabeth [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); Centre RMX, 80, avenue Felix Faure, 75105 Paris (France); Filmont, Jean-Emmanuel [Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); American Hospital of Paris, Nuclear Medicine, 63, boulevard Victor Hugo - BP 109, 92202 Neuilly sur Seine Cedex (France)

    2009-01-15

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005].

  8. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  9. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  10. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  11. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  12. Early-Dynamic Positron Emission Tomography (PET)/Computed Tomography and PET Angiography for Endoleak Detection After Endovascular Aneurysm Repair.

    Science.gov (United States)

    Drescher, Robert; Gühne, Falk; Freesmeyer, Martin

    2017-06-01

    To propose a positron emission tomography (PET)/computed tomography (CT) protocol including early-dynamic and late-phase acquisitions to evaluate graft patency and aneurysm diameter, detect endoleaks, and rule out graft or vessel wall inflammation after endovascular aneurysm repair (EVAR) in one examination without intravenous contrast medium. Early-dynamic PET/CT of the endovascular prosthesis is performed for 180 seconds immediately after intravenous injection of F-18-fluorodeoxyglucose. Data are reconstructed in variable time frames (time periods after tracer injection) to visualize the arterial anatomy and are displayed as PET angiography or fused with CT images. Images are evaluated in view of vascular abnormalities, graft configuration, and tracer accumulation in the aneurysm sac. Whole-body PET/CT is performed 90 to 120 minutes after tracer injection. This protocol for early-dynamic PET/CT and PET angiography has the potential to evaluate vascular diseases, including the diagnosis of complications after endovascular procedures.

  13. An economic evaluation of positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) for the diagnosis of breast cancer recurrence.

    Science.gov (United States)

    Auguste, P; Barton, P; Hyde, C; Roberts, T E

    2011-04-01

    To review the published economic studies that have evaluated positron emission tomography/computed tomography (PET/CT) in the treatment of recurrent breast cancer, and to develop and carry out a model-based economic evaluation to investigate the relative cost-effectiveness of PET/CT to detect breast cancer recurrence compared with conventional work-up. A systematic review of economic and diagnostic evidence for PET/CT in diagnosis of breast cancer recurrence. The original databases searched include MEDLINE (Ovid) (1950 to week 5 May 2009), EMBASE (Ovid) (1980 to 2009 week 22) and the NHS Economic Evaluation Database. An updated search was conducted for each database from May 2009 to week 4 April 2010. A decision tree was developed in TREEAGE software (TreeAge Software Inc., Williamstown, MA, USA). The relevant data on accuracy, sensitivity and specificity of each diagnostic test were linked in the model, to costs and the primary outcome measure, cost per quality-adjusted life-year (QALY). The model estimated the mean cost associated with each diagnostic procedure and assumed that patients entering the model were aged 50-75 years. The results of the cost-effectiveness analysis are presented in terms of the incremental cost-effectiveness ratios (ICERs). The ICER for the strategy of PET compared with conventional work-up was estimated at £29,300 per QALY; the ICER for PET/CT compared with PET was £ 31,000 per QALY; and the ICER for PET/CT combined with conventional work-up versus PET/CT was £ 42,100. Clearly, for each additional diagnostic test that is added to PET, the more expensive the package becomes, but also the more effective it becomes in terms of QALYs gained. The probabilistic sensitivity analysis shows that at a willingness-to-pay threshold of £ 20,000 per QALY, conventional work-up is the preferred option. Only data from indirect comparisons are available from the accuracy review, and there is some uncertainty about whether the data defining the

  14. The clinical usefulness of 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) in follow-up of curatively resected pancreatic cancer patients.

    Science.gov (United States)

    Jung, Woohyun; Jang, Jin-Young; Kang, Mee Joo; Chang, Ye Rim; Shin, Yong Chan; Chang, Jihoon; Kim, Sun-Whe

    2016-01-01

    Computed tomography and serum tumor markers have limited value in detecting recurrence after curative surgery of pancreatic cancer. This study evaluated the clinical utility of 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) in diagnosing recurrence. One hundred ten patients underwent curative resection of pancreatic cancer were enrolled. The diagnostic value of abdominal computed tomography (CT), PET-CT and serum carbohydrate antigen (CA) 19-9 concentration were compared. The prognostic value of SUVmax on PET-CT was evaluated. PET-CT showed relatively higher sensitivity (84.5% vs. 75.0%) and accuracy (84.5% vs. 74.5%) than CT, whereas PET-CT plus CT showed greater sensitivity (97.6%) and accuracy (90.0%) than either alone. In detecting distant recurrences, PET-CT showed higher sensitivity (83.1% vs. 67.7%) than CT. Nineteen patients showed recurrences only on PET-CT, with eleven having invisible or suspected benign lesions on CT, and eight had recurrences in areas not covered by CT. SUVmax over 3.3 was predictive of poor survival after recurrence. PET-CT in combination with CT improves the detection of recurrence. PET-CT was especially advantageous in detecting recurrences in areas not covered by CT. If active post-operative surveillance after curative resection of pancreatic cancer is deemed beneficial, then it should include PET-CT combined with CT. Copyright © 2015 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  15. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  16. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    Science.gov (United States)

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (PCT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  17. Clinical value of 18F-fluorodihydroxyphenylalanine positron emission tomography/computed tomography (18F-DOPA PET/CT) for detecting pheochromocytoma

    International Nuclear Information System (INIS)

    Luster, Markus; Zeich, Katrin; Glatting, Gerhard; Buck, Andreas K.; Solbach, Christoph; Reske, Sven N.; Karges, Wolfram; Pauls, Sandra; Verburg, Frederik A.; Dralle, Henning; Neumaier, Bernd; Mottaghy, Felix M.

    2010-01-01

    In detecting pheochromocytoma (PHEO), positron emission tomography (PET) with the radiolabelled amine precursor 18 F-fluorodihydroxyphenylalanine ( 18 F-DOPA) offers excellent specificity, while computed tomography (CT) provides high sensitivity and ability to localize lesions; therefore, the combination of these modalities could be advantageous in this setting. The aim of this study was to investigate whether combined 18 F-DOPA PET/CT more accurately detects and localizes PHEO lesions than does each modality alone. 18 F-DOPA PET, CT and 18 F-DOPA PET/CT images of 25 consecutive patients undergoing diagnostic scanning of suspected sporadic or multiple endocrine neoplasia type 2 syndrome-associated PHEO were reviewed retrospectively in randomized sequence. Two blinded observers scored the images regarding the likelihood of PHEO being present and localizable. Results were correlated with subsequent clinical history and, when available, histology. Of the 19 lesions detected by all three modalities, PET identified each as positive for PHEO, but was unable to definitively localize 15 of 19 (79%). CT could definitively localize all 19 lesions, but could not definitively diagnose or exclude PHEO in 18 of 19 (95%) lesions. Furthermore, CT falsely identified as negative for PHEO one lesion which was judged to be positive for this tumor by both PET and PET/CT. Only in PET/CT scans were all 19 lesions accurately characterized and localized. On a per-patient basis, the sensitivity of 18 F-DOPA PET/CT for PHEO was 100% and the specificity 88%, with a 100% positive predictive value and an 88% negative predictive value. 18 F-DOPA PET/CT more accurately diagnoses and localizes adrenal and extra-adrenal masses suspicious for PHEO than do 18 F-DOPA PET or CT alone. (orig.)

  18. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  19. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    International Nuclear Information System (INIS)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T.; O'Brien, Maureen M.

    2018-01-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  20. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); O' Brien, Maureen M. [Cincinnati Children' s Hospital Medical Center, Division of Oncology, Cancer and Blood Disease Institute, Cincinnati, OH (United States)

    2018-02-15

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  1. Isolated thymic Langerhans cell histiocytosis discovered on F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT).

    Science.gov (United States)

    Turpin, Sophie; Carret, Anne-Sophie; Dubois, Josée; Buteau, Chantal; Patey, Natalie

    2015-11-01

    The thymic infiltration in young patients with multisystemic Langerhans cell histiocytosis and its radiologic features are well known. However, isolated thymic disease has seldom been reported in the literature. We report the case of a 10-month-old child admitted for fever of unknown origin. Whole-body F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) was performed to identify a focus of infection. It demonstrated an unusual aspect of the thymus, which led to further investigation and revealed isolated infiltration of the thymus by Langerhans cell histiocytosis. The patient was treated accordingly and is now disease free. As evaluation of Langerhans cell histiocytosis patients with F-18 FDG PET/CT is becoming more frequent, it is important to be aware of the scintigraphical characteristics of thymic Langerhans cell histiocytosis.

  2. Isolated thymic Langerhans cell histiocytosis discovered on F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Turpin, Sophie [CHU Sainte-Justine, Nuclear Medicine, Montreal (Canada); Carret, Anne-Sophie [CHU Sainte-Justine, Hemato-Oncology, Montreal (Canada); Dubois, Josee [CHU Sainte-Justine, Radiology, Montreal (Canada); Buteau, Chantal [CHU Sainte-Justine, Infectious Diseases, Montreal (Canada); Patey, Natalie [CHU Sainte-Justine, Pathology, Montreal (Canada)

    2015-11-15

    The thymic infiltration in young patients with multisystemic Langerhans cell histiocytosis and its radiologic features are well known. However, isolated thymic disease has seldom been reported in the literature. We report the case of a 10-month-old child admitted for fever of unknown origin. Whole-body F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) was performed to identify a focus of infection. It demonstrated an unusual aspect of the thymus, which led to further investigation and revealed isolated infiltration of the thymus by Langerhans cell histiocytosis. The patient was treated accordingly and is now disease free. As evaluation of Langerhans cell histiocytosis patients with F-18 FDG PET/CT is becoming more frequent, it is important to be aware of the scintigraphical characteristics of thymic Langerhans cell histiocytosis. (orig.)

  3. Use of computed tomography and positron emission tomography/computed tomography for staging of local extent in patients with malignant pleural mesothelioma.

    Science.gov (United States)

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM stage was assessed by 3 independent readers. Relative and absolute underestimation and overestimation were compared with pathological tumor stage. Sensitivity, specificity, and accuracy for differentiation between stages T2 and T3 were assessed. Interobserver agreement between the readers was analyzed (κ). Positron emission tomography/CT and CT underestimated T stage in up to 30% of the cases. Positron emission tomography/CT had a higher accuracy for tumor extent compared with CT (PET/CT: 0.92; CT: 0.84). The accuracy for nodal staging was higher for CT than for PET/CT (PET/CT: 0.78; CT: 0.87). Concerning International Mesothelioma Interest Group classification, PET/CT improved the accuracy of preoperative staging compared with CT (PET/CT: 0.91; CT: 0.82). Interobserver agreement was moderate for CT (0.48-0.62) and good for PET/CT (0.64-0.83) for T staging. For nodal staging, interobserver agreement was fair to moderate for CT and good for PET/CT (CT: 0.37-0.51; PET/CT: 0.73-0.76). Positron emission tomography/CT is more accurate and has a lower interobserver variability for clinical intrathoracic staging of MPM compared with CT. Nevertheless PET/CT underestimated tumor stage in a substantial number of cases, showing the need for a more accurate imaging technology or approach.

  4. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  5. False-positive uptake on 2-[18F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) in oncological imaging

    International Nuclear Information System (INIS)

    Culverwell, A.D.; Scarsbrook, A.F.; Chowdhury, F.U.

    2011-01-01

    With the increasing utilization of integrated positron-emission tomography/computed tomography (PET/CT) using the glucose analogue 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) in oncological imaging, it is important for radiologists and nuclear medicine physicians to be aware that FDG uptake is not specific for malignancy, as many different physiological variants and benign pathological conditions can also exhibit increased glucose metabolism. Such false-positive FDG uptake often arises outside the area of primary interest and may mimic malignant disease, thereby confounding accurate interpretation of PET/CT studies. With the use of illustrative clinical cases, this article will provide a systematic overview of potential interpretative pitfalls and illustrate how such unexpected findings can be appropriately evaluated.

  6. Serotonin synthesis studied with positron emission tomography, (PET)

    DEFF Research Database (Denmark)

    Honoré, Per Gustaf Hartvig; Lundquist, Pinelopi

    Positron emission tomography (PET) has the potential to study the biosynthesis and release of serotonin (5HT) at brain serotonergic neurons. PET requires probe compounds with specific attributes to enable imaging and quantification of biological processes. This section focuses on probes to measure...

  7. Clinical value of {sup 18}F-fluorodihydroxyphenylalanine positron emission tomography/computed tomography ({sup 18}F-DOPA PET/CT) for detecting pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Luster, Markus; Zeich, Katrin; Glatting, Gerhard; Buck, Andreas K.; Solbach, Christoph; Reske, Sven N. [University of Ulm, Department of Nuclear Medicine, Ulm (Germany); Karges, Wolfram [RWTH Aachen, Division of Endocrinology and Diabetes, Aachen (Germany); Pauls, Sandra [University of Ulm, Department of Radiology, Ulm (Germany); Verburg, Frederik A. [University of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Dralle, Henning [University Halle-Wittenberg, Department of General, Visceral and Vascular Surgery, Halle (Germany); Neumaier, Bernd [University of Ulm, Department of Nuclear Medicine, Ulm (Germany); Max-Planck-Institut fuer Neurologische Forschung, Section for Radiochemistry, Cologne (Germany); Mottaghy, Felix M. [University of Ulm, Department of Nuclear Medicine, Ulm (Germany); RWTH Aachen, Department of Nuclear Medicine, Aachen (Germany)

    2010-03-15

    In detecting pheochromocytoma (PHEO), positron emission tomography (PET) with the radiolabelled amine precursor {sup 18}F-fluorodihydroxyphenylalanine ({sup 18}F-DOPA) offers excellent specificity, while computed tomography (CT) provides high sensitivity and ability to localize lesions; therefore, the combination of these modalities could be advantageous in this setting. The aim of this study was to investigate whether combined {sup 18}F-DOPA PET/CT more accurately detects and localizes PHEO lesions than does each modality alone. {sup 18}F-DOPA PET, CT and {sup 18}F-DOPA PET/CT images of 25 consecutive patients undergoing diagnostic scanning of suspected sporadic or multiple endocrine neoplasia type 2 syndrome-associated PHEO were reviewed retrospectively in randomized sequence. Two blinded observers scored the images regarding the likelihood of PHEO being present and localizable. Results were correlated with subsequent clinical history and, when available, histology. Of the 19 lesions detected by all three modalities, PET identified each as positive for PHEO, but was unable to definitively localize 15 of 19 (79%). CT could definitively localize all 19 lesions, but could not definitively diagnose or exclude PHEO in 18 of 19 (95%) lesions. Furthermore, CT falsely identified as negative for PHEO one lesion which was judged to be positive for this tumor by both PET and PET/CT. Only in PET/CT scans were all 19 lesions accurately characterized and localized. On a per-patient basis, the sensitivity of {sup 18}F-DOPA PET/CT for PHEO was 100% and the specificity 88%, with a 100% positive predictive value and an 88% negative predictive value. {sup 18}F-DOPA PET/CT more accurately diagnoses and localizes adrenal and extra-adrenal masses suspicious for PHEO than do {sup 18}F-DOPA PET or CT alone. (orig.)

  8. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  9. Evaluation of pulmonary nodules and lung cancer with one-inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT

    International Nuclear Information System (INIS)

    Moodie, K.; Lau, E.; Hicks, R. J.; Cherk, M. H.; Turlakow, A.; Skinner, S.; Kelly, M. J.; Kalff, V.

    2009-01-01

    Full text: Dedicated positron emission tomography (PET)/CT scanners using BGO and related detectors (d-PET) have become standard imaging instruments in many malignancies. Hybrid gamma camera systems using Nal detectors in coincidence mode (g-PET) have been compared to d-PET but reported usefulness has been variable when gamma cameras with half-inch to three-fourth-inch thick crystals have been used without CT. Our aim was to compare g-PET with a 1-in.-thick crystal and inbuilt CT for lesion localization and attenuation correction (g-PET/CT) and d-PET/CT in patients presenting with potential and confirmed lung malignancies. One hour after 18F-fluorodeoxyglucose (FDG), patients underwent BGO d-PET/CT from jaw to proximal thigh. This was followed by one to two bed position g-PET/CT 194 + 27 min after FDG. Each study pair was independently analysed with concurrent CT. d-PET/CT was interpreted by a radiologist experienced in both PET and CT, and g-PET/CT by consensus reading of an experienced PET physician and an experienced CT radiologist, A TNM score was assigned and studies were then unblinded and compared. Fifty-seven patients underwent 58 scan pairs over 2 years. Eighty-nine percent concordance was shown between g-PET/CT and d-PET/CT for the assessment of I intrapulmonary lesions, with 100% concordance for intrapulmonary lesions I >10 mm (36 of 36). Eighty-eight per cent (51 of 58) concordance was shown between g-PET/CTand d-PET/CTforTNM staging. Coincidence imaging usingan optimized dual-head 1-in.-thick crystal gamma camera with inbuilt CT compares reasonably well with dedicated PET/CT for evaluation of indeterminate pulmonary lesions and staging of pulmonary malignancies and may be of some] value when d-PET/CT is not readily available.

  10. [Diagnostic use of positron emission tomography in France: from the coincidence gamma-camera to mobile hybrid PET/CT devices].

    Science.gov (United States)

    Talbot, Jean-Noël

    2010-11-01

    Positron emission tomography (PET) is a well-established medical imaging method. PET is increasingly used for diagnostic purposes, especially in oncology. The most widely used radiopharmaceutical is FDG, a glucose analogue. Other radiopharmaceuticals have recently been registered or are in development. We outline technical improvements of PET machines during more than a decade of clinical use in France. Even though image quality has improved considerably and PET-CT hybrid machines have emerged, spending per examination has remained remarkably constant. Replacement and maintenance costs have remained in the range of 170-190 Euros per examination since 1997, whether early CDET gamma cameras or the latest time-of-flight PET/CT devices are used. This is mainly due to shorter acquisition times and more efficient use of FDG New reimbursement rates for PET/CT are needed in France in order to favor regular acquisition of state-of-the-art devices. One major development is the coupling of PET and MR imaging.

  11. Recent developments in positron emission tomography (PET) instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  12. Recent developments in positron emission tomography (PET) instrumentation

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs

  13. Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    International Nuclear Information System (INIS)

    Hirakawa, Tomoko; Okumura, Yoshihiro; Kato, Jun

    2012-01-01

    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results. (author)

  14. Three dimensional positron-CT: 3D-PET

    International Nuclear Information System (INIS)

    Ishii, K.

    2000-01-01

    Positron-CT, namely the positron emission tomograph (PET) provides us the metabolism images obtained by the administration of the drug labeled by the positron emission nuclide in the human body. For example, the carbohydrate metabolism image is obtained by the administration of glucose labelled by 18 F-radioisotopes, and it can be applied to early detection of the cancer and research of high-order function of the brain. As well as X-ray CT, the examine receives the exposure in the positron CT. 3D-PET is based on the solid measurement of γ-rays, therefore, the detection sensitivity of 3D-PET becomes very high and it is possible to drastically reduce the dose of the positron emission nuclide. Because the exposure is reduced to the utmost, the positron CT diagnosis would be possible for the child and the exposure of positron CT doctor in charge can be also reduced. This ideal functional diagnostic imaging equipment, namely, 3D-PET is introduced here. (author)

  15. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging.

    Science.gov (United States)

    Grueneisen, Johannes; Nagarajah, James; Buchbender, Christian; Hoffmann, Oliver; Schaarschmidt, Benedikt Michael; Poeppel, Thorsten; Forsting, Michael; Quick, Harald H; Umutlu, Lale; Kinner, Sonja

    2015-08-01

    This study aimed to assess the diagnostic performance of integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) of the breast for lesion detection and local tumor staging of patients with primary breast cancer in comparison to PET/computed tomography (CT) and MRI. The study was approved by the local institutional review board. Forty-nine patients with biopsy-proven invasive breast cancer were prospectively enrolled in our study. All patients underwent a PET/CT, and subsequently, a contrast-enhanced PET/MRI of the breast after written informed consent was obtained before each examination. Two radiologists independently evaluated the corresponding data sets (PET/CT, PET/MRI, and MRI) and were instructed to identify primary tumors lesions as well as multifocal/multicentric and bilateral disease. Furthermore, the occurrence of lymph node metastases was assessed, and the T-stage for each patient was determined. Histopathological verification of the local tumor extent and the axillary lymph node status was available for 30 of 49 and 48 of 49 patients, respectively. For the remaining patients, a consensus characterization was performed for the determination of the T-stage and nodal status, taking into account the results of clinical staging, PET/CT, and PET/MRI examinations. Statistical analysis was performed to test for differences in diagnostic performance between the different imaging procedures. P values less than 0.05 were considered to be statistically significant. Positron emission tomography/MRI and MRI correctly identified 47 (96%) of the 49 patients with primary breast cancer, whereas PET/CT enabled detection of 46 (94%) of 49 breast cancer patients and missed a synchronous carcinoma in the contralateral breast in 1 patient. In a lesion-by-lesion analysis, no significant differences could be obtained between the 3 imaging procedures for the identification of primary breast cancer lesions (P > 0.05). Positron emission tomography/MRI and

  16. Positron emission tomography (PET) in psychiatry

    International Nuclear Information System (INIS)

    Buchsbaum, M.S.

    1984-01-01

    In the past the approach to the brain has been necessarily indirect, employing peripheral fluids to assess central and regional neurochemical processes. Blood, urine, skin and muscle biopsy, and cerebrospinal fluid are valuable reflectors of the neurochemical and neuropharmacological activity of the brain, but are removed in time and place from disordered thought processes and diluted by the products of both functional and dysfunctional brain systems. Biopsy studies have helped in studying the functional disorders of organs like the liver, but they are destructive to the brain and less useful because unlike these organs, the brain has a regional variation in its chemistry. The experimental insights from animal studies focusing on the pharmacology of individual cell groups - in striatum or locus coeruleus, for example - cannot easily or unambigiously be applied to clinical populations. Positron emission tomography (PET) is a versatile approach utilizing the mathematics of x-ray transmission scanning (CT scanning) to produce slice images of radioisotope distribution. PET makes possible a wide range of metabolic studies. Positron emitters such as carbon-11 or fluorine-18 can be used to label glucose, amino acids, drugs, neurotransmitter precursors, and many other molecules and examine their distribution and fate in discrete cell groups

  17. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  19. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  20. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer: A Prospective Comparative Study of Dual-Time-Point FDG-PET/CT, Contrast-Enhanced CT, and Bone Scintigraphy.

    Science.gov (United States)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina; Falch, Kirsten; Hansen, Jeanette Ansholm; Farahani, Ziba Ahangarani; Petersen, Henrik; Larsen, Lisbet Brønsro; Duvnjak, Sandra; Buskevica, Inguna; Bektas, Selma; Søe, Katrine; Jylling, Anne Marie Bak; Ewertz, Marianne; Alavi, Abass; Høilund-Carlsen, Poul Flemming

    2016-06-01

    To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group. © 2016 by American Society of Clinical Oncology.

  1. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  2. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  3. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  4. Quantification in dynamic and small-animal positron emission tomography

    NARCIS (Netherlands)

    Disselhorst, Johannes Antonius

    2011-01-01

    This thesis covers two aspects of positron emission tomography (PET) quantification. The first section addresses the characterization and optimization of a small-animal PET/CT scanner. The sensitivity and resolution as well as various parameters affecting image quality (reconstruction settings, type

  5. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  6. Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Imaging in Patients With Carcinoma of the Nasopharynx: Diagnostic Accuracy and Impact on Clinical Management

    International Nuclear Information System (INIS)

    Gordin, Arie; Golz, Avishay; Daitzchman, Marcello; Keidar, Zohar; Bar-Shalom, Rachel; Kuten, Abraham; Israel, Ora

    2007-01-01

    Purpose: To assess the value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in patients with nasopharyngeal carcinoma as compared with PET and conventional imaging (CI) alone, and to assess the impact of PET/CT on further clinical management. Methods and Materials: Thirty-three patients with nasopharyngeal carcinoma had 45 PET/CT examinations. The study was a retrospective analysis. Changes in patient care resulting from the PET/CT studies were recorded. Results: Positron emission tomography/computed tomography had sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 92%, 90%, 90%, 90%, and 91%, respectively, as compared with 92%, 65%, 76%, 86%, and 80% for PET and 92%, 15%, 60%, 60%, and 60% for CI. Imaging with PET/CT altered further management of 19 patients (57%). Imaging with PET/CT eliminated the need for previously planned diagnostic procedures in 11 patients, induced a change in the planned therapeutic approach in 5 patients, and guided biopsy to a specific metabolically active area inside an edematous region in 3 patients, thus decreasing the chances for tissue sampling errors and avoiding damage to nonmalignant tissue. Conclusions: In cancer of the nasopharynx, the diagnostic performance of PET/CT is better than that of stand-alone PET or CI. Positron emission tomography/computed tomography had a major impact on further clinical management in 57% of patients

  7. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  8. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PETCT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  9. Positron emission tomography in the management of cervix cancer patients

    International Nuclear Information System (INIS)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H.; Chargari, C.; Bauduceau, O.

    2009-01-01

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with 18 F-fluoro-2-deoxy-D-glucose ( 18 F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  10. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  11. Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomy

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Yap, Kenneth S.K.; Cherk, Martin H.; Kalff, Victor; Powell, Anne

    2013-01-01

    The aim of this study is to compare the results of positron emission tomography (PET)/CT with bremsstrahlung imaging following Y-90 radiation synovectomy. All patients referred to our institution for Y-90 radiation synovectomy between July 2011 and February 2012 underwent both PET/CT and bremsstrahlung planar (±single photon emission computed tomography (SPECT) or SPECT/CT) imaging at 4 or 24 h following administration of Y-90 silicate colloid. PET image acquisition was performed for between 15 and 20min. In patients who underwent SPECT, side-by-side comparison with PET was performed and image quality/resolution scored using a five-point scale. The distribution pattern of Y-90 on PET and bremsstrahlung imaging was compared with the intra- or extra-articular location of Y-90 activity on fused PET/CT. Thirteen joints (11 knees and two ankles) were imaged with both PET/CT and planar bremsstrahlung imaging with 12 joints also imaged with bremsstrahlung SPECT. Of the 12 joints imaged with SPECT, PET image quality/resolution was superior in 11 and inferior in one. PET demonstrated a concordant distribution pattern compared with bremsstrahlung imaging in all scans, with the pattern classified as diffuse in 12 and predominantly focal in one. In all 12 diffuse scans, PET/CT confirmed the Y-90 activity to be located intra-articularly. In the one predominantly focal scan, the fused PET/CT images localised the Y-90 activity to mostly lie in the extra-articular space of the knee. PET/CT can provide superior image quality compared with bremsstrahlung imaging and may enable reliable detection of extra-articular Y-90 activity when there are focal patterns on planar bremsstrahlung imaging.

  12. Modern imaging methods: positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) combination

    International Nuclear Information System (INIS)

    Votrubova, J.; Belohlavek, O.

    2004-01-01

    An overview of the title topic is presented. Attention is paid to the technical principles of PET and CT, indications for PET and PET/CT examination, and achievements of the PET Centre of the Na Homolce hospital. (P.A.)

  13. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) Imaging in the Staging and Prognosis of Inflammatory Breast Cancer

    International Nuclear Information System (INIS)

    Alberini, J.L.; Wartski, M.; Gontier, E.; Madar, O.; Pecking, A.P.; Lerebours, F.; Fourme, E.; Le Stanc, E.; Cherel, P.; Alberini, J.L.

    2009-01-01

    Background: To prospectively assess fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) staging and prognosis value in patients with suspected inflammatory breast cancer (IBC). Methods: Sixty-two women (mean age 50.7 ± 11.4 years) presenting with unilateral inflammatory breast tumors (59 invasive carcinomas; 3 mastitis) underwent a PET/CT scan before biopsy. Results: PET/CT scan was positive for the primary malignant tumor in 100% and false positive in 2 of 3 benign mastitis. In 59 IBC patients, FDG nodal foci were detected in axillary (90%; n = 53) and extra-axillary areas (56%; n = 33) ipsilateral to the cancer. Compared with clinical examination, the axillary lymph node status by PET/CT was upstaged and down staged in 35 and 5 patients, respectively. In 7 of 9 N0 patients, the axillary lymph node positivity on PET/CT was correct, as revealed by pathological post surgery assessment (not available in the 2 remaining patients). The nodal foci were compared with preoperative fine needle aspiration and/or pathological post chemotherapy findings available in 44 patients and corresponded to 38 true positive, 4 false-negative, and 2 false-positive cases. In 18 of 59 IBC patients (31%), distant lesions were found. On the basis of a univariate analysis of the first enrolled patients (n = 42), among 28 patients who showed intense tumoral uptake (standard uptake value(max)≥5), the 11 patients with distant lesions had a worse prognosis than the 17 patients without distant lesions (P =.04). Conclusions: FDG-PET/CT imaging provides additional invaluable information regarding nodal status or distant metastases in IBC patients and should be considered in the initial staging. It seems also that some prognostic information can be derived from FDG uptake characteristics. (authors)

  14. Positron Emission Tomography imaging with the SmartPET system

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom)], E-mail: cooperrj@ornl.gov; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Harkness, L.J.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P.; Mather, A.R. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD (United Kingdom)

    2009-07-21

    The Small Animal Reconstruction Tomograph for Positron Emission Tomography (SmartPET) project is the development of a small animal Positron Emission Tomography (PET) demonstrator based on the use of High-Purity Germanium (HPGe) detectors and state of the art digital electronics. The experimental results presented demonstrate the current performance of this unique system. By performing high precision measurements of one of the SmartPET HPGe detectors with a range of finely collimated gamma-ray beams the response of the detector as a function of gamma-ray interaction position has been quantified, facilitating the development of parametric Pulse Shape Analysis (PSA) techniques and algorithms for the correction of imperfections in detector performance. These algorithms have then been applied to data from PET imaging measurements using two such detectors in conjunction with a specially designed rotating gantry. In this paper we show how the use of parametric PSA approaches allows over 60% of coincident events to be processed and how the nature and complexity of an event has direct implications for the quality of the resulting image.

  15. [Prognostic value of (18)F-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) in extensive-stage small cell lung cancer].

    Science.gov (United States)

    Ding, C Y; Guo, Z; Li, Y Y; Li, T R

    2017-11-23

    Objective: To investigated the prognostic value of (18)F-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) in extensive-stage small cell lung cancer (ES -SCLC). Methods: Fifty-five patients with ES-SCLC who underwent pretreatment (18)F-FDG PET-CT were retrospectively recruited in this study. The correlations of maximum standardized uptake value (SUVmax) of primary lesion, metabolic tumor volume (MTV) of primary lesion (MTVp), total lesion glycolysis (TLG) of primary lesion (TLGp), the highest SUVmax of all lesions, the sum of metabolic volume (MTV sum), the sum of total lesions glycolysis (TLGsum) and clinical factors were analyzed. Results: The SUVmax, MTVp, TLGp, the highest SUVmax, MTVsum and TLGsum of 55 patients were 11.34±7.02, 29.61 cm(3,) 207.72, 13.61±7.10, 123.57 cm(3) and 988.48, respectively. The SUVmax of primary lesion, MTVp and TLGp were correlated with tumor type and the maximal tumor length, respectively(all P CT has certain prognostic value of patients with ES-SCLC. MTVsum and TLGsum are the independent predictors of PFS, and TLGsum is also an independent predictor of OS.

  16. Use of positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Gonzalez E, Patricio; Jofre E, Josefina; Massardo V, Teresa; Humeres, Pamela; Canessa G, Jose; Sierralta C, Paulina

    2002-01-01

    The value of PET (Positron Emission Tomography) in colorectal cancer is presented. PET is a novel technique that uses F-18-FDG (fluorodeoxiglucose) to assess glucose metabolism by whole body imaging. It has been demonstrated that malignant cells have both increase of glucose uptake and utilization. In colorectal cancer, PET is indicated for staging, assess recurrence, liver metastasis and treatment follow-up. PET is more sensitive and specific than CT (Computed Tomography) and is cost effective. In 30% of cases PET may change patient management, avoiding unnecessary procedures (au)

  17. Images to visualize the brain. PET: Positron Emission Tomography

    International Nuclear Information System (INIS)

    1992-01-01

    Diagnosis instrument and research tool, Positron Emission Tomography permits advanced technological developments on positron camera, on molecule labelling and principally on very complex 3D image processing. Cyceron Centre in Caen-France works on brain diseases and try to understand the mechanism of observed troubles and to assess the treatment efficiency with PET. Service Hospitalier Frederic Joliot of CEA-France establishes a mapping of cognitive functions in PET as vision areas, anxiety regions, brain organization of language, different attention forms, voluntary actions and motor functions

  18. Positron emission tomography of incidentally detected small pulmonary nodules

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Dirksen, A

    2004-01-01

    The aim of this study was to assess the value of fluorodeoxyglucose positron emission tomography (FDG PET) imaging of small pulmonary nodules incidentally detected by spiral computed tomography (CT) in a high-risk population. Ten patients (five females, five males, aged 54-72 years) were recruited...

  19. Positron Emission Tomography: Its 65 years

    International Nuclear Information System (INIS)

    Del Guerra, A.; Belcari, N.; Bisogni, M.

    2016-01-01

    Positron Emission Tomography (PET) is a well-established imaging technique for in vivo molecular imaging. In this review after a brief history of PET there are presented its physical principles and the technology that has been developed for bringing PET from a bench experiment to a clinical indispensable instrument. The limitations and performance of the PET tomographs are discussed, both as for the hardware and software aspects. The status of art of clinical, preclinical and hybrid scanners (i.e., PET/CT and PET/MR) is reported. Finally the actual trend and the recent and future technological developments are fully illustrated.

  20. Clinicopathological and prognostic relevance of uptake level using 18F-fluorodeoxyglucose positron emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in primary breast cancer

    International Nuclear Information System (INIS)

    Ueda, Shigeto; Tsuda, Hitoshi; Asakawa, Hideki

    2008-01-01

    Using integrated 18 F-fluorodeoxyglucose positron emission tomography/computed tomography fusion imaging ( 18 F-FDG PET/CT), the clinical significance of 18 F-FDG uptake was evaluated in patients with primary breast cancer. Clinicopathological correlation with the level of maximum standardized uptake values (SUV) 60 min obtained from preoperative 18 F-FDG PET/CT were examined in 152 patients with primary breast cancer. The prognostic impact of the level of SUV was explored using simulated prognosis derived from computed program Adjuvant! in 136 (89%) patients with invasive ductal carcinoma (IDC). High SUV level was significantly correlated with tumor invasive size (≤2 cm) (P 18 F-FDG would be predictive of poor prognosis in patients with primary breast cancer, and aggressive features of cancer cells in patients with early breast cancer. 18 F-FDG PET/CT could be a useful tool to pretherapeutically predict biological characteristics and baseline risk of breast cancer. (author)

  1. {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) Imaging in the Staging and Prognosis of Inflammatory Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alberini, J.L.; Wartski, M.; Gontier, E.; Madar, O.; Pecking, A.P. [Nuclear Medicine Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Lerebours, F. [Oncology Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Fourme, E. [Biostatistics Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Le Stanc, E. [Nuclear Medicine Department, Foch Hospital, Suresnes (France); Cherel, P. [Radiology Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Alberini, J.L. [School of Medicine, Versailles Saint-Quentin University (France)

    2009-07-01

    Background: To prospectively assess fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) staging and prognosis value in patients with suspected inflammatory breast cancer (IBC). Methods: Sixty-two women (mean age 50.7 {+-} 11.4 years) presenting with unilateral inflammatory breast tumors (59 invasive carcinomas; 3 mastitis) underwent a PET/CT scan before biopsy. Results: PET/CT scan was positive for the primary malignant tumor in 100% and false positive in 2 of 3 benign mastitis. In 59 IBC patients, FDG nodal foci were detected in axillary (90%; n = 53) and extra-axillary areas (56%; n = 33) ipsilateral to the cancer. Compared with clinical examination, the axillary lymph node status by PET/CT was upstaged and down staged in 35 and 5 patients, respectively. In 7 of 9 N0 patients, the axillary lymph node positivity on PET/CT was correct, as revealed by pathological post surgery assessment (not available in the 2 remaining patients). The nodal foci were compared with preoperative fine needle aspiration and/or pathological post chemotherapy findings available in 44 patients and corresponded to 38 true positive, 4 false-negative, and 2 false-positive cases. In 18 of 59 IBC patients (31%), distant lesions were found. On the basis of a univariate analysis of the first enrolled patients (n = 42), among 28 patients who showed intense tumoral uptake (standard uptake value(max){>=}5), the 11 patients with distant lesions had a worse prognosis than the 17 patients without distant lesions (P =.04). Conclusions: FDG-PET/CT imaging provides additional invaluable information regarding nodal status or distant metastases in IBC patients and should be considered in the initial staging. It seems also that some prognostic information can be derived from FDG uptake characteristics. (authors)

  2. Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions: A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients.

    Science.gov (United States)

    Seith, Ferdinand; Gatidis, Sergios; Schmidt, Holger; Bezrukov, Ilja; la Fougère, Christian; Nikolaou, Konstantin; Pfannenberg, Christina; Schwenzer, Nina

    2016-01-01

    Attenuation correction (AC) in fully integrated positron emission tomography (PET)/magnetic resonance (MR) systems plays a key role for the quantification of tracer uptake. The aim of this prospective study was to assess the accuracy of standardized uptake value (SUV) quantification using MR-based AC in direct comparison with computed tomography (CT)-based AC of the same PET data set on a large patient population. Sixty-six patients (22 female; mean [SD], 61 [11] years) were examined by means of combined PET/CT and PET/MR (11C-choline, 18F-FDG, or 68Ga-DOTATATE) subsequently. Positron emission tomography images from PET/MR examinations were corrected with MR-derived AC based on tissue segmentation (PET(MR)). The same PET data were corrected using CT-based attenuation maps (μ-maps) derived from PET/CT after nonrigid registration of the CT to the MR-based μ-map (PET(MRCT)). Positron emission tomography SUVs were quantified placing regions of interest or volumes of interest in 6 different body regions as well as PET-avid lesions, respectively. The relative differences of quantitative PET values when using MR-based AC versus CT-based AC were varying depending on the organs and body regions assessed. In detail, the mean (SD) relative differences of PET SUVs were as follows: -7.8% (11.5%), blood pool; -3.6% (5.8%), spleen; -4.4% (5.6%)/-4.1% (6.2%), liver; -0.6% (5.0%), muscle; -1.3% (6.3%), fat; -40.0% (18.7%), bone; 1.6% (4.4%), liver lesions; -6.2% (6.8%), bone lesions; and -1.9% (6.2%), soft tissue lesions. In 10 liver lesions, distinct overestimations greater than 5% were found (up to 10%). In addition, overestimations were found in 2 bone lesions and 1 soft tissue lesion adjacent to the lung (up to 28.0%). Results obtained using different PET tracers show that MR-based AC is accurate in most tissue types, with SUV deviations generally of less than 10%. In bone, however, underestimations can be pronounced, potentially leading to inaccurate SUV quantifications. In

  3. Comprehensive Oncologic Imaging in Infants and Preschool Children With Substantially Reduced Radiation Exposure Using Combined Simultaneous ¹⁸F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance Imaging: A Direct Comparison to ¹⁸F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Gatidis, Sergios; Schmidt, Holger; Gücke, Brigitte; Bezrukov, Ilja; Seitz, Guido; Ebinger, Martin; Reimold, Matthias; Pfannenberg, Christina A; Nikolaou, Konstantin; Schwenzer, Nina F; Schäfer, Jürgen F

    2016-01-01

    The aim of this study was to evaluate the clinical applicability and technical feasibility of fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance imaging (MRI) compared with FDG PET/computed tomography (CT) in young children focusing on lesion detection, PET quantification, and potential savings in radiation exposure. Twenty examinations (10 PET/CT and 10 PET/MRI examinations) were performed prospectively in 9 patients with solid tumors (3 female, 6 male; mean age, 4.8 [1-6] years). Fluorodeoxyglucose PET/CT and FDG PET/MRI were performed sequentially after a single tracer injection. Lesion detection and analysis were performed independently in PET/CT and PET/MRI. Potential changes in diagnostic or therapeutic patient management were recorded. Positron emission tomography quantification in PET/MRI was evaluated by comparing standardized uptake values resulting from MRI-based and CT-based attenuation correction. Effective radiation doses of PET and CT were estimated. Twenty-one PET-positive lesions were found congruently in PET/CT and PET/MRI. Magnetic resonance imaging enabled significantly better detection of morphologic PET correlates compared with CT. Eight suspicious PET-negative lesions were identified by MRI, of which one was missed in CT. Sensitivity, specificity, and accuracy for correct lesion classification were not significantly different (90%, 47%, and 62% in PET/CT; 100%, 68%, and 79% in PET/MRI, respectively). In 4 patients, the use of PET/MRI resulted in a potential change in diagnostic management compared with PET/CT, as local and whole-body staging could be performed within 1 single examination. In 1 patient, PET/MRI initiated a change in therapeutic management. Positron emission tomography quantification using MRI-based attenuation correction was accurate compared with CT-based attenuation correction. Higher standardized uptake value deviations of about 18% were observed in the lungs due to misclassification in MRI

  4. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  5. Physical and technical basis of positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Bauer, R.

    1994-01-01

    Positron emission tomography utilizes the annihilation of positrons, generating pairs of gamma quanta which are emitted in opposing directions. 'Electronic collimation' is performed by coincident detection of both quanta. Thus, there is no need for mechanical collimators and no limiting connection between sensitivity and spatial resolution. Transversal tomograms are reconstructed from the projection data by means of highly sophisticated data processing. The half life of the most positron emitters used in medical applications is short and of the order of some minutes. Therefore, many positron emitters have to be produced on-side by means of a cyclotron. PET is superior to SPECT with respect to physical and technical aspects, but the high costs of PET limit its wide-spread use up to now. (orig.) [de

  6. [Indications and instructions to patients for a positron emission tomography-PET scan. The importance of the hybridic PET/CT-computerised tomography scan and which specialty should be responsible for its function].

    Science.gov (United States)

    Grammaticos, Philip; Datseris, Ioannis; Gerali, Sofia; Papantoniou, Vassilios; Valsamaki, Pipitsa; Boundas, Dimitrios

    2007-01-01

    Indications and instructions to patients for performing a positron emission tomography - PET scan are mentioned. Although PET camera was developed in 1970 its clinical indications were established in about 1998. The hybridic PET/CT- computerized tomography scanner appeared in 2001 and its clinical indications are still under discussion. These discussions refer to both the use of PET/CT as an acquisition correction and anatomic localization device for PET images (AC/A) and to its use as a diagnostic CT scan (dCT). Most of the patients submitted for a PET scan have already done a dCT scan. This was the case in 286 out of the first 300 patients referred to "Evangelismos" hospital in Athens for a PET scan. These two scans can be matched electronically. Extra cost, space, personnel and radiation absorption dose especially in children, are additional factors to be considered in using the PET/CT scanner. The specialty of Nuclear Medicine is now based on the PET camera, its best part and main equipment for molecular imaging. It is very much easier and faster for a Nuclear Medicine physician who routinely reports tomographic PET and SPET images, to be familiar with the CT images than for a Radiologist to get to "know how" about the PET camera and the whole Nuclear Medicine Department. Nuclear Medicine is about open radiation sources, molecular imaging, specific radio-pharmacology, radiobiology, radiation protection etc, while on the other hand in some countries, Nuclear Physicians have already spent, as part of their official training, six months in a Radiology Department whose function is considered to be at least 25% about the CT scanner. We come to the conclusion that the PET/CT scanner should be under the responsibility of the Nuclear Medicine Department and the Radiologist should act as an advisor.

  7. Positron emission tomography for staging of oesophageal and gastroesophageal malignancy

    NARCIS (Netherlands)

    Kole, AC; Plukker, JT; Nieweg, OE; Vaalburg, W

    Positron emission tomography (PET) with [F-18]-fluoro-2-deoxy-D-glucose (FDG) was prospectively investigated as a means of detecting metastatic disease in patients with oesophageal tumours and compared with computerized tomography (CT), with the surgical findings as a gold standard. Twenty-six

  8. Fluorodeoxyglucose positron emission tomography-computed tomography findings in a case of xanthogranulomatous pyelonephritis

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram; Shah, Hardik

    2013-01-01

    Xanthogranulomatous pyelonephritis (XGNP) is an uncommon condition characterized by chronic suppurative renal inflammation that leads to progressive parenchymal destruction. This condition can clinically present as recurrent urinary tract infections, flank pain, hematuria, and occasionally sepsis, and weight loss. This condition is usually associated with obstructing renal calculus. We present 18-fluorodeoxyglucose positron emission tomography-computed tomography (18-FDG PET/CT) findings in an elderly male suffering from pyrexia and weight loss and suspected urinary tract infection. PET/CT findings in this case lead to diagnosis of XGNP. This diagnosis should be kept in mind while evaluating similar symptoms and PET/CT scan findings. PMID:24019680

  9. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Mathis, C.A.; Moyer, B.R.; Huesman, R.H.; Derenzo, S.E.

    1983-01-01

    Positron emission tomography (PET) offers the opportunity to noninvasively measure heart muscle blood perfusion, oxygen utilization, metabolism of fatty acids, sugars and amino acids. This paper reviews physiological principles which are basic to PET instrumentation for imaging the heart and gives examples of the application of positron emission tomography for measuring myocardial flow and metabolism. 33 references, 11 figures, 1 table

  10. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  11. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  12. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Lecomte, R.; Bentourkia, M.; Benard, F.

    2002-01-01

    Positron Emission Tomography is a sophisticated molecular imaging technique, using a special scanner, that displays the functional status of tissues in the body at the cellular level (their metabolism). It is a diagnostic scan that provides the physician with information not available with traditional anatomic studies such as CT or MRI. PET can detect changes in cell function (disease) long before they are evident as physical (anatomic) changes seen on CT or MRI. In this way PET can add important information about many diseases allowing the physician to make a diagnosis often much earlier than with anatomic imaging techniques such as CT or MRI alone. In addition, in cases where an abnormality is noted on CT or MRI, PET can help differentiate benign changes from changes due to disease. PET scanning also typically images the entire body, unlike CT/MRI which is usually broken up into specific limited body section scans. All cells use glucose as an energy source but cancer cells use much more since they are growing much faster and out of control. This is the basis of imaging with F-18 FDG glucose, the radiotracer agent use in a PET oncology study. The abnormal, accelerated glucose used by cancer cells is detected by the PET scanner that processes the emissions from the F-18 FDG glucose by abnormally high levels of metabolism (tumor)

  13. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  14. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  15. Tomography methods for diagnostic examination of cerebrovascular disease: a comparative evaluation of SPECT, PET and MR/CT findings

    International Nuclear Information System (INIS)

    Reiche, W.; Kaiser, H.J.; Weiller, C.; Altehoefer, C.; Buell, U.; Isensee, C.

    1991-01-01

    Single Photon Emissions Computerized Tomography (SPECT), Positron Emissions Tomography (PET), Magnetic Resonance Tomography (MR), and Transmission Computerized Tomography (CT) complement each other and lead to a consideration of the cerebrovascular disease under patho-physiological aspects. Indications for the combined application of functionally oriented (SPECT/PET) and morphologically oriented (CT/MR) examination methods with cerebrovascular disease are presented. (orig./MG) [de

  16. Preoperative PET/CT in early-stage breast cancer

    DEFF Research Database (Denmark)

    Bernsdorf, M; Berthelsen, A K; Timmermans-Wielenga, Vera

    2012-01-01

    The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer.......The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer....

  17. Positron emission tomography

    International Nuclear Information System (INIS)

    Marchenkov, N.S.

    2000-01-01

    The foundations of the positron emission tomography (PET), widely used for the medical diagnostics, are considered. The brief description of the cyclotron for production of radionuclides, applied in the PET, the target devices for manufacturing the position emitters, the moduli for the radiopharmaceuticals synthesis (RPS) for the PET is presented. The necessity and concept of complete automation of the RPS for the PET are discussed [ru

  18. Function's evaluation, perfusion and metabolism by positron emission tomography associated with multislice tomography (PET/CT) in patient with previous diagnosis to myocardial necrosis

    International Nuclear Information System (INIS)

    Campisi, Roxana; Aramayo, Natalia; Osorio, Amilcar

    2010-01-01

    A 64-years-old male patient with previous diagnosis of myocardial necrosis as assessed by myocardial perfusion gated single photon emission computed tomography (gSPECT) with 3-vessel-disease, left ventricular dysfunction and symptomatic by epigastric pain. The patient was referred for myocardial viability assessment by positron emission tomography (PET) to define clinical management decision. (authors) [es

  19. Patterns of brown fat uptake of 18F-fluorodeoxyglucose in positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Fluorodeoxyglucose (FDG) positron emission tomography (PET) has become the common imaging modality in oncological practice. FDG uptake is seen in brown adipose tissue in a significant number of patients. Recognizing the uptake patterns is important for optimal FDG PET interpretation. The introduction of PET/computed tomography (PET/CT) revolutionized PET imaging, bringing much-needed anatomical information. Careful review and correlation of FDG PET images with anatomical imaging should be performed to characterize accurately any lesion having high FDG uptake

  20. Evaluation of dosimetric techniques in positrons emission tomography and computerized tomography (PET/CT)

    International Nuclear Information System (INIS)

    Pinto, Gabriella Montezano

    2014-01-01

    Among diagnostic techniques PET/CT is one of those with the highest dose delivery to the patient as a cause of external exposure to X-rays, and the use of a radiopharmaceutical that results in a high energy gamma emission. The dosimetry of these two components becomes important in order to optimize and justify the technique. Various dosimetric techniques are found in literature without a consensus of the best to use. With the advances in technological and consequent equipment configuration changes, upgrades and variation in methodologies, particularly in computed tomography, a standardization of these techniques is required. Previous studies show that CT is responsible for 70 % of the dose delivered to the patient in PET/CT examinations. Thus, many researchers have been focused on CT dose optimization protocols studies. This work analyzes the doses involved in a PET/CT oncology protocol by using an Alderson female anthropomorphic phantom in a public hospital of Rio de Janeiro city. The dose estimate for PET examination resulting from the use of 18 F - FDG radiopharmaceutical was conducted through dose factors published in ICRP 106; the dose for CT was estimated and compared by calculation of the absorbed doses to patients according to four methods: thermoluminescent dosimetry (TL0100) distributed in critical organs of the Alderson phantom; measurements of CTOI according to AAPM number 96; correction factor for effective diameter SSOE (AAPM Number 204); and simulation by ImPACT program For CT, the results in terms of effective dose presented (TLO, CTOI and ImPACT) ± 5 % maximum variations between methodologies. Considering medium absorbed dose (TLO, SSOE and ImPACT) the results differed in ± 7 % from each other. These findings demonstrate that parameters provided by the manufacturer on the console can be used to have a primary approach of both, absorbed and effective doses to the patient since that a quality assurance program of these parameters are adopted in

  1. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  2. Novel targets for positron emission tomography (PET) radiopharmaceutical tracers for visualization of neuroinflammation

    Science.gov (United States)

    Shchepetkin, I.; Shvedova, M.; Anfinogenova, Y.; Litvak, M.; Atochin, D.

    2017-08-01

    Non-invasive molecular imaging techniques can enhance diagnosis of neurological diseases to achieve their successful treatment. Positron emission tomography (PET) imaging can identify activated microglia and provide detailed functional information based on molecular biology. This imaging modality is based on detection of isotope labeled tracers, which emit positrons. The review summarizes the developments of various radiolabeled ligands for PET imaging of neuroinflammation.

  3. Positron emission tomography imaging of gene expression

    International Nuclear Information System (INIS)

    Tang Ganghua

    2001-01-01

    The merging of molecular biology and nuclear medicine is developed into molecular nuclear medicine. Positron emission tomography (PET) of gene expression in molecular nuclear medicine has become an attractive area. Positron emission tomography imaging gene expression includes the antisense PET imaging and the reporter gene PET imaging. It is likely that the antisense PET imaging will lag behind the reporter gene PET imaging because of the numerous issues that have not yet to be resolved with this approach. The reporter gene PET imaging has wide application into animal experimental research and human applications of this approach will likely be reported soon

  4. FDG-PET/CT in the evaluation of anal carcinoma

    International Nuclear Information System (INIS)

    Cotter, Shane E.; Grigsby, Perry W.; Siegel, Barry A.

    2006-01-01

    Purpose: Surgical staging and treatment of anal carcinoma has been replaced by noninvasive staging studies and combined modality therapy. In this study, we compare computed tomography (CT) and physical examination to [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) in the staging of carcinoma of the anal canal, with special emphasis on determination of spread to inguinal lymph nodes. Methods and Materials: Between July 2003 and July 2005, 41 consecutive patients with biopsy-proved anal carcinoma underwent a complete staging evaluation including physical examination, CT, and 2-FDG-PET/CT. Patients ranged in age from 30 to 89 years. Nine men were HIV-positive. Treatment was with standard Nigro regimen. Results: [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) detected 91% of nonexcised primary tumors, whereas CT visualized 59%. FDG-PET/CT detected abnormal uptake in pelvic nodes of 5 patients with normal pelvic CT scans. FDG-PET/CT detected abnormal nodes in 20% of groins that were normal by CT, and in 23% without abnormality on physical examination. Furthermore, 17% of groins negative by both CT and physical examination showed abnormal uptake on FDG-PET/CT. HIV-positive patients had an increased frequency of PET-positive lymph nodes. Conclusion: [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography detects the primary tumor more often than CT. FDG-PET/CT detects substantially more abnormal inguinal lymph nodes than are identified by standard clinical staging with CT and physical examination

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  6. Fluorine-18-fluorodeoxyglucose Positron Emission Tomography in Diffuse Large B-cell Lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen Juul; Nielsen, Anne Lerberg; Pedersen, Lars Møller

    2014-01-01

    Diffuse large B-cell lymphoma (DLBCL) is an aggressive and potentially curable type of lymphoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) is part of clinical routine for DLBCL in most hospitals and also recommended for staging and end-of-therapy evaluation. FDG......-PET/computed tomography (CT) is able to identify nodal and extranodal sites with greater accuracy than CT alone. Little evidence supports the use of surveillance FDG-PET imaging in the follow-up setting because of high rates of false-positive scans and because most studies are retrospective. This article discusses FDG...

  7. Quantification of atherosclerotic plaque activity and vascular inflammation using [18-F] fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT).

    Science.gov (United States)

    Mehta, Nehal N; Torigian, Drew A; Gelfand, Joel M; Saboury, Babak; Alavi, Abass

    2012-05-02

    Conventional non-invasive imaging modalities of atherosclerosis such as coronary artery calcium (CAC) and carotid intimal medial thickness (C-IMT) provide information about the burden of disease. However, despite multiple validation studies of CAC, and C-IMT, these modalities do not accurately assess plaque characteristics, and the composition and inflammatory state of the plaque determine its stability and, therefore, the risk of clinical events. [(18)F]-2-fluoro-2-deoxy-D-glucose (FDG) imaging using positron-emission tomography (PET)/computed tomography (CT) has been extensively studied in oncologic metabolism. Studies using animal models and immunohistochemistry in humans show that FDG-PET/CT is exquisitely sensitive for detecting macrophage activity, an important source of cellular inflammation in vessel walls. More recently, we and others have shown that FDG-PET/CT enables highly precise, novel measurements of inflammatory activity of activity of atherosclerotic plaques in large and medium-sized arteries. FDG-PET/CT studies have many advantages over other imaging modalities: 1) high contrast resolution; 2) quantification of plaque volume and metabolic activity allowing for multi-modal atherosclerotic plaque quantification; 3) dynamic, real-time, in vivo imaging; 4) minimal operator dependence. Finally, vascular inflammation detected by FDG-PET/CT has been shown to predict cardiovascular (CV) events independent of traditional risk factors and is also highly associated with overall burden of atherosclerosis. Plaque activity by FDG-PET/CT is modulated by known beneficial CV interventions such as short term (12 week) statin therapy as well as longer term therapeutic lifestyle changes (16 months). The current methodology for quantification of FDG uptake in atherosclerotic plaque involves measurement of the standardized uptake value (SUV) of an artery of interest and of the venous blood pool in order to calculate a target to background ratio (TBR), which is

  8. Imaging prostate cancer: an update on positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Turkbey, Baris; Choyke, Peter

    2010-01-01

    , and molecular imaging information. Developments in imaging technologies, specifically magnetic resonance imaging (MRI) and positron emission tomography (PET)/computed tomography (CT), have improved the detection rate of prostate cancer. MRI has improved lesion detection and local staging. Furthermore, MRI...

  9. Rare case of isolated splenic metastases from gastric cancer detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Shibu, Deepu; Sugunan Shinto, Ajit; Sivanesan, Balasubramanian

    2013-01-01

    We report a rare case of isolated splenic metastasis from gastric cancer detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography (PET/CT). A 55-year-old man with gastric cancer 1 year post surgery, evaluated with PET/CT showed focal, intense uptake in the spleen, with no other abnormal findings. On splenectomy, the lesion was confirmed as metastasis from gastric cancer pathologically. (author)

  10. Comparison of CT and positron emission tomography/CT coregistered images in planning radical radiotherapy in patients with non-small-cell lung cancer

    International Nuclear Information System (INIS)

    MacManus, M.; D'Costa, I.; Ball, D.; Everitt, S.; Andrews, J.; Ackerly, T.; Binns, D.; Lau, E.; Hicks, R.J.; Weih, L.

    2007-01-01

    Imaging with F-18 fluorodeoxyglucose positron emission tomography (PET) significantly improves lung cancer staging, especially when PET and CT information are combined. We describe a method for obtaining CT and PET images at separate acquisitions, which allows coregistration and incorporation of PET information into the radiotherapy (RT) planning process for non-small-cell lung cancer. The influence of PET information on RT planning was analysed for 10 consecutive patients. Computed tomography and PET images were acquired with the patient in an immobilization device, in the treatment position. Using specially written software, PET and CT data were coregistered using fiducial markers and imported into our RT planning system (Cadplan version 6). Treatment plans were prepared with and without access to PET/CT coregistered images and then compared. PET influenced the treatment plan in all cases. In three cases, geographic misses (gross tumour outside planning target volume) would have occurred had PET not been used. In a further three cases, better planning target volume marginal coverage was achieved with PET. In four patients, three with atelectasis, there were significant reductions in V20 (percentage of the total lung volume receiving 20 Gy or more). Use of coregistered PET/CT images significantly altered treatment plans in a majority of cases. This method could be used in routine practice at centres without access to a combined PET/CT scanner

  11. Fluorodeoxyglucose positron emission tomography scan may be helpful in the case of ductal variant prostate cancer when prostate specific membrane antigen ligand positron emission tomography scan is negative

    International Nuclear Information System (INIS)

    McEwan, Louise M.; Wong, David; Yaxley, John

    2017-01-01

    Gallium-68 prostate specific membrane antigen ligand (Ga-68 PSMA) positron emission tomography/computed tomography (PET/CT) scanning is emerging as a useful imaging modality for the staging of suspected and known recurrent or metastatic prostate cancer and in staging of newly diagnosed higher grade prostate cancer. However, we have observed at our institution that in some cases of the more aggressive ductal variant, Ga-68 PSMA uptake has sometimes been poor compared with prominent 18-fluorodeoxyglucose (F-18 FDG) avidity seen in F-18 FDG PET/CT, which would suggest that FDG PET/CT scans are important in staging of ductal pattern prostate cancer.

  12. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  13. Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Liu, Fengxia; Zhang, Qingyu; Zhu, Dezhi; Li, Zhenfeng; Li, Jianmin; Wang, Boim; Zhou, Dongsheng; Dong, Jinlei

    2015-09-01

    To investigate the performance of fluorine-18-fluorodeoxyglucose (F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the diagnosis, staging, restaging, and recurrence surveillance of bone sarcoma by systematically reviewing and meta-analyzing the published literature.To retrieve eligible studies, we searched the MEDLINE, Embase, and the Cochrane Central library databases using combinations of following Keywords: "positron emission tomography" or "PET," and "bone tumor" or "bone sarcoma" or "sarcoma." Bibliographies from relevant articles were also screened manually. Data were extracted and the pooled sensitivity, specificity, and diagnostic odds ratio (DOR), on an examination-based or lesion-based level, were calculated to appraise the diagnostic accuracy of F-FDG PET and PET/CT. All statistical analyses were performed using Meta-Disc 1.4.Forty-two trials were eligible. The pooled sensitivity and specificity of PET/CT to differentiate primary bone sarcomas from benign lesions were 96% (95% confidence interval [CI], 93-98) and 79% (95% CI, 63-90), respectively. For detecting recurrence, the pooled results on an examination-based level were sensitivity 92% (95% CI, 85-97), specificity 93% (95% CI, 88-96), positive likelihood ratio (PLR) 10.26 (95% CI, 5.99-17.60), and negative likelihood ratio (NLR) 0.11 (95% CI, 0.05-0.22). For detecting distant metastasis, the pooled results on a lesion-based level were sensitivity 90% (95% CI, 86-93), specificity 85% (95% CI, 81-87), PLR 5.16 (95% CI, 2.37-11.25), and NLR 0.15 (95% CI, 0.11-0.20). The accuracies of PET/CT for detecting local recurrence, lung metastasis, and bone metastasis were satisfactory. Pooled outcome estimates of F-FDG PET were less complete compared with those of PET/CT.F-FDG PET and PET/CT showed a high sensitivity for diagnosing primary bone sarcoma. Moreover, PET/CT demonstrated excellent accuracy for the staging, restaging, and recurrence surveillance of bone sarcoma. However

  14. Trails on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Leading to Diagnosis of Testicular Adrenal Rest Tumor.

    Science.gov (United States)

    Kashyap, Raghava

    2018-01-01

    Testicular adrenal rest tumors (TARTs) are secondary to hypertrophy of adrenal rest cells in the rete testis in settings of hypersecretion of androgens. We present a case of congenital adrenal hyperplasia with TART with clues to the diagnosis on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). To the best of our knowledge, this is the first reported case on the role of 18 F-FDG PET/CT in TART.

  15. Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma

    Science.gov (United States)

    Liu, Fanxiao; Zhang, Qingyu; Zhu, Dezhi; Li, Zhenfeng; Li, Jianmin; Wang, Boim; Zhou, Dongsheng; Dong, Jinlei

    2015-01-01

    Abstract To investigate the performance of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the diagnosis, staging, restaging, and recurrence surveillance of bone sarcoma by systematically reviewing and meta-analyzing the published literature. To retrieve eligible studies, we searched the MEDLINE, Embase, and the Cochrane Central library databases using combinations of following Keywords: “positron emission tomography” or “PET,” and “bone tumor” or “bone sarcoma” or “sarcoma.” Bibliographies from relevant articles were also screened manually. Data were extracted and the pooled sensitivity, specificity, and diagnostic odds ratio (DOR), on an examination-based or lesion-based level, were calculated to appraise the diagnostic accuracy of 18F-FDG PET and PET/CT. All statistical analyses were performed using Meta-Disc 1.4. Forty-two trials were eligible. The pooled sensitivity and specificity of PET/CT to differentiate primary bone sarcomas from benign lesions were 96% (95% confidence interval [CI], 93–98) and 79% (95% CI, 63–90), respectively. For detecting recurrence, the pooled results on an examination-based level were sensitivity 92% (95% CI, 85–97), specificity 93% (95% CI, 88–96), positive likelihood ratio (PLR) 10.26 (95% CI, 5.99–17.60), and negative likelihood ratio (NLR) 0.11 (95% CI, 0.05–0.22). For detecting distant metastasis, the pooled results on a lesion-based level were sensitivity 90% (95% CI, 86–93), specificity 85% (95% CI, 81–87), PLR 5.16 (95% CI, 2.37–11.25), and NLR 0.15 (95% CI, 0.11–0.20). The accuracies of PET/CT for detecting local recurrence, lung metastasis, and bone metastasis were satisfactory. Pooled outcome estimates of 18F-FDG PET were less complete compared with those of PET/CT. 18F-FDG PET and PET/CT showed a high sensitivity for diagnosing primary bone sarcoma. Moreover, PET/CT demonstrated excellent accuracy for the staging

  16. Spectrum of fluorodeoxyglucose-positron emission tomography/computed tomography and magnetic resonance imaging findings of ovarian tumors.

    Science.gov (United States)

    Kitajima, Kazuhiro; Ueno, Yoshiko; Maeda, Tetsuo; Murakami, Koji; Kaji, Yasushi; Kita, Masato; Suzuki, Kayo; Sugimura, Kazuro

    2011-11-01

    The purpose of this article is to review fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI) findings in a variety of benign, malignant, and borderline malignant ovarian tumors. It is advantageous to become familiar with the wide variety of FDG-PET/CT findings of this entity. Benign ovarian tumors generally have faint uptake, whereas endometriomas, fibromas, and teratomas show mild to moderate uptake. Malignant ovarian tumors generally have intense uptake, whereas tumors with a small solid component often show minimal uptake.

  17. Positron-molecule interactions and corresponding positron attachment to molecules. As a basis for positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Tachikawa, Masanori; Kimura, Mineo; Pichl, Lukas

    2007-01-01

    Through positron and electron interactions, they annihilate emitting primarily two gamma rays with 180-degree opposite directions. Positron spectroscopy using the characteristics of these gamma rays has been employed for analyzing various properties of material as well as for positron emission tomography (PET). However, its fundamental physics of positron-electron interactions and resulting features of emitting gamma rays are not well understood. By obtaining better understanding of positron interactions, it should become possible to provide the firm bases for positron spectroscopy in finer accuracy and quality. Here, we propose a significant mechanism for positron annihilation through positron attachment process, which may help increase the quality of positron spectroscopy. (author)

  18. Positron emission tomography (PET) for oncologic applications in oral region

    International Nuclear Information System (INIS)

    Shozushima, Masanori; Terasaki, Kazunori

    2004-01-01

    A rapidly emerging clinical application of positron emission tomography (PET) is the detection of cancer with radionuclide tracer, because it provides information unavailable by ultrasound, computed tomography or magnetic resonance imaging. The most commonly used radiotracer for PET oncologic imaging is fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG). Early studies show PET has potential value in viewing the region of the tumor, detecting, staging, grading, monitoring response to anticancer therapy, and differentiating recurrent or residual disease from post treatment changes. However, limitations of FDG-PET in the head and neck region, namely, physiological FDG uptake in the salivary glands and palatine tonsils, have been reported, increasing the false-positive rates in image interpretation. This review was designed to address these distinctions of oral cancer PET imaging: specialization of PET equipment, cancer cell metabolism, proliferation and tracers, clinical diagnosis of oral cancer with PET, pitfalls in oncologic diagnosis with FDG-PET imaging. (author)

  19. Positron emission tomography studies of brain receptors

    International Nuclear Information System (INIS)

    Maziere, B.; Maziere, M.

    1991-01-01

    Probing the regional distribution and affinity of receptors in the brain, in vivo, in human and non human primates has become possible with the use of selective ligands labelled with positron emitting radionuclides and positron emission tomography (PET). After describing the techniques used in positron emission tomography to characterize a ligand receptor binding and discussing the choice of the label and the limitations and complexities of the in vivo approach, the results obtained in the PET studies of various neurotransmission systems: dopaminergic, opiate, benzodiazepine, serotonin and cholinergic systems are reviewed

  20. Quality assurance and radiation safety in positron emission tomography

    International Nuclear Information System (INIS)

    Kmetyuk, Ya.V.; Radosh, H.V.; Bezshyyko, O.A.; Golinka-Bezshyyko, L.O.; Kadenko, I.M.; Kazinova, O.A.; Nagai, A.O.

    2012-01-01

    Scientific studies, clinical experience and economic analysis have shown that the positron emission tomography (PET) is clinically and cost effective cancer diagnostics method. Combined PET and computed tomography (PET/CT) has proven clinical utility, particularly in the diagnosis, staging or restaging malignant disease and metastases, surgical planning, radiation therapy planning and evaluation of treatment response. The use of PET/CT has grown substantially in the past few years, with an increasing number of hospitals and installations of PET/CT imaging centers each year. In the same time combination of 2 procedures, each of which impart a radiation dose and, as a result, increases the deleterious influence for health, creates additional radiation safety issues. In these conditions the role of quality assurance (QA) and quality control (QC) programs is getting more and more important. We considered main QA and radiation safety requirements for whole PET technology chain from radio-pharmacy facilities to PET/CT scanning and patient release criteria. All these issues were considered and assessed having the example of PET facilities and technology chain of All-Ukrainian Center for Radiosurgery of the Clinical Hospital 'Feofania'

  1. Improving PET Quantification of Small Animal [68Ga]DOTA-Labeled PET/CT Studies by Using a CT-Based Positron Range Correction.

    Science.gov (United States)

    Cal-Gonzalez, Jacobo; Vaquero, Juan José; Herraiz, Joaquín L; Pérez-Liva, Mailyn; Soto-Montenegro, María Luisa; Peña-Zalbidea, Santiago; Desco, Manuel; Udías, José Manuel

    2018-01-19

    Image quality of positron emission tomography (PET) tracers that emits high-energy positrons, such as Ga-68, Rb-82, or I-124, is significantly affected by positron range (PR) effects. PR effects are especially important in small animal PET studies, since they can limit spatial resolution and quantitative accuracy of the images. Since generators accessibility has made Ga-68 tracers wide available, the aim of this study is to show how the quantitative results of [ 68 Ga]DOTA-labeled PET/X-ray computed tomography (CT) imaging of neuroendocrine tumors in mice can be improved using positron range correction (PRC). Eighteen scans in 12 mice were evaluated, with three different models of tumors: PC12, AR42J, and meningiomas. In addition, three different [ 68 Ga]DOTA-labeled radiotracers were used to evaluate the PRC with different tracer distributions: [ 68 Ga]DOTANOC, [ 68 Ga]DOTATOC, and [ 68 Ga]DOTATATE. Two PRC methods were evaluated: a tissue-dependent (TD-PRC) and a tissue-dependent spatially-variant correction (TDSV-PRC). Taking a region in the liver as reference, the tissue-to-liver ratio values for tumor tissue (TLR tumor ), lung (TLR lung ), and necrotic areas within the tumors (TLR necrotic ) and their respective relative variations (ΔTLR) were evaluated. All TLR values in the PRC images were significantly different (p DOTA-labeled PET/CT imaging of mice with neuroendocrine tumors, hence demonstrating that these techniques could also ameliorate the deleterious effect of the positron range in clinical PET imaging.

  2. Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Erdi, Yusuf E.; Rosenzweig, Kenneth; Erdi, Alev K.; Macapinlac, Homer A.; Hu, Yu-Chi; Braban, Louise E.; Humm, John L.; Squire, Olivia D.; Chui, Chen-Shou; Larson, Steven M.; Yorke, Ellen D.

    2002-01-01

    Purpose: Many patients with non-small cell lung cancer (NSCLC) receive external beam radiation therapy as part of their treatment. Three-dimensional conformal radiation therapy (3DCRT) commonly uses computed tomography (CT) to accurately delineate the target lesion and normal tissues. Clinical studies, however, indicate that positron emission tomography (PET) has higher sensitivity than CT in detecting and staging of mediastinal metastases. Imaging with fluoro-2-deoxyglucose (FDG) PET in conjunction with CT, therefore, can improve the accuracy of lesion definition. In this pilot study, we investigated the potential benefits of incorporating PET data into the conventional treatment planning of NSCLC. Case-by-case, we prospectively analyzed planning target volume (PTV) and lung toxicity changes for a cohort of patients. Materials and methods: We have included 11 patients in this study. They were immobilized in the treatment position and CT simulation was performed. Following CT simulation, PET scanning was performed in the treatment position using the same body cast that was produced for CT simulation and treatment. The PTV, along with the gross target volume (GTV) and normal organs, was first delineated using the CT data set. The CT and PET transmission images were then registered in the treatment planning system using either manual or automated methods, leading to consequent registration of the CT and emission images. The PTV was then modified using the registered PET emission images. The modified PTV is seen simultaneously on both CT and PET images, allowing the physician to define the PTV utilizing the information from both data sets. Dose-volume histograms (DVHs) for lesion and normal organs were generated using both CT-based and PET+CT-based treatment plans. Results: For all patients, there was a change in PTV outline based on CT images versus CT/PET fused images. In seven out of 11 cases, we found an increase in PTV volume (average increase of 19%) to

  3. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  4. Is there any role of positron emission tomography computed tomography for predicting resectability of gallbladder cancer?

    Science.gov (United States)

    Kim, Jaihwan; Ryu, Ji Kon; Kim, Chulhan; Paeng, Jin Chul; Kim, Yong-Tae

    2014-05-01

    The role of integrated (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography computed tomography (PET-CT) is uncertain in gallbladder cancer. The aim of this study was to show the role of PET-CT in gallbladder cancer patients. Fifty-three patients with gallbladder cancer underwent preoperative computed tomography (CT) and PET-CT scans. Their medical records were retrospectively reviewed. Twenty-six patients underwent resection. Based on the final outcomes, PET-CT was in good agreement (0.61 to 0.80) with resectability whereas CT was in acceptable agreement (0.41 to 0.60) with resectability. When the diagnostic accuracy of the predictions for resectability was calculated with the ROC curve, the accuracy of PET-CT was higher than that of CT in patients who underwent surgical resection (P=0.03), however, there was no difference with all patients (P=0.12). CT and PET-CT had a discrepancy in assessing curative resection in nine patients. These consisted of two false negative and four false positive CT results (11.3%) and three false negative PET-CT results (5.1%). PET-CT was in good agreement with the final outcomes compared to CT. As a complementary role of PEC-CT to CT, PET-CT tended to show better prediction about resectability than CT, especially due to unexpected distant metastasis.

  5. 2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) for postchemotherapy seminoma residual lesions

    DEFF Research Database (Denmark)

    Bachner, M; Loriot, Y; Gross-Goupil, M

    2012-01-01

    2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients.......2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients....

  6. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [JWG University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank [Hannover Medical School, Department of Neuroradiology, Hannover (Germany); Berding, Georg [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Weissenborn, Karin; Ahl, Bjoern [Hannover Medical School, Department of Neurology, Hannover (Germany)

    2006-10-15

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [{sup 15}O]H{sub 2}O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  7. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    International Nuclear Information System (INIS)

    Bisdas, Sotirios; Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank; Berding, Georg; Weissenborn, Karin; Ahl, Bjoern

    2006-01-01

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [ 15 O]H 2 O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  8. Use of positron emission tomography (PET) for the diagnosis of large-vessel vasculitis.

    Science.gov (United States)

    Loricera, J; Blanco, R; Hernández, J L; Martínez-Rodríguez, I; Carril, J M; Lavado, C; Jiménez, M; González-Vela, C; González-Gay, M Á

    2015-01-01

    The term vasculitis encompasses a heterogeneous group of diseases that share the presence of inflammatory infiltrates in the vascular wall. The diagnosis of large-vessel vasculitis is often a challenge because the presenting clinical features are nonspecific in many cases and they are often shared by different types of autoimmune and inflammatory diseases including other systemic vasculitides. Moreover, the pathogenesis of large-vessel vasculitis is not fully understood. Nevertheless, the advent of new imaging techniques has constituted a major breakthrough to establish an early diagnosis and a promising tool to monitor the follow-up of patients with largevessel vasculitis. This is the case of the molecular imaging with the combination of positron emission tomography with computed tomography (PET/CT) using different radiotracers, especially the (18)F-fluordeoxyglucose ((18)F-FDG). In this review we have focused on the contribution of (18)F-FDG PET in the diagnosis of large-vessel vasculitis. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  9. Contrast-enhanced 18F-fluorodeoxyglucose positron emission tomography/computed tomography in immunoglobulin G4-related retroperitoneal fibrosis

    International Nuclear Information System (INIS)

    Sharma, Punit; Chatterjee, Piyali

    2015-01-01

    Immunoglobulin G4 (IgG4)-related disease encompasses a wide variety of immune disorders previously thought be distinct. IgG4-related retroperitoneal fibrosis is one such entity. Metabolic imaging with 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) can be useful in the management of IgG4-related retroperitoneal fibrosis. We here discuss the case of 63-year-old male with IgG4-related retroperitoneal fibrosis and the role, 18 F-FDG PET/CT played in his management

  10. Computer tomography, magnetic resonance imaging, and positron emission tomography or positron emission tomography/computer tomography for detection of metastatic lymph nodes in patients with ovarian cancer: A meta-analysis

    International Nuclear Information System (INIS)

    Yuan Ying; Gu Zhaoxiang; Tao Xiaofeng; Liu Shiyuan

    2012-01-01

    Objectives: To compare the diagnostic performances of computed tomography (CT), magnetic resonance (MR) imaging, and positron emission tomography (PET or PET/CT) for detection of metastatic lymph nodes in patients with ovarian cancer. Methods: Relevant studies were identified with MEDLINE and EMBASE from January 1990 to July 2010. We estimated the weighted summary sensitivities, specificities, OR (odds ratio), and summary receiver operating characteristic (sROC) curves of each imaging technique and conducted pair-wise comparisons using the two-sample Z-test. Meta-regression, subgroup analysis, and funnel plots were also performed to explain the between-study heterogeneity. Results: Eighteen eligible studies were included, with a total of 882 patients. PET or PET/CT was a more accurate modality (sensitivity, 73.2%; specificity, 96.7%; OR [odds ratio], 90.32). No significant difference was detected between CT (sensitivity, 42.6%; specificity, 95.0%; OR, 19.87) and MR imaging (sensitivity, 54.7%; specificity, 88.3%; OR, 12.38). Meta-regression analyses and subgroup analyses revealed no statistical difference. Funnel plots with marked asymmetry suggested a publication bias. Conclusion: FDG-PET or FDG-PET/CT is more accurate than CT and MR imaging in the detection of lymph node metastasis in patients with ovarian cancer.

  11. Role of positron emission tomography-computed tomography in endometrial cancer

    Science.gov (United States)

    Erdemoğlu, Evrim; Çerçi, Sevim Süreyya; Erdemoğlu, Ebru; Yalçın, Yakup; Tatar, Burak

    2017-01-01

    Objective: The efficacy of preoperative 18F-fluoro-D-glucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) in endometrium cancer is controversial. We examined the efficacy of PET-CT and the association between maximum standardized uptake value (SUVmax) and prognostic factors in endometrial cancer. Materials and Methods: Thirty patients with endometrial cancer underwent preoperative 18F-FDG/PET-CT. The patients were treated with abdominal hysterectomy with bilateral salpingo-oophorectomy, and bilateral systemic pelvic lymphadenectomy was planned for all patients; paraaortic lymphadenectomy was performed in patients with intermediate and high risk. Tumor histology, grade, depth of myometrial invasion, maximum tumor diameter, lymphovascular invasion, nodal status, and ovarian/adnexal metastases were recorded. Results: The mean primary tumor diameter was reported smaller in PET-CT and the effect size of PET-CT was -0.60. The kappa value was 0.06 for myometrial invasion. Pelvic lymph node metastasis was reported in 22.2% of patients in PET-CT. However, 3.7% of patients had pelvic lymph node metastasis. The kappa value for pelvic lymph node metastasis was 0.23, and sensitivity, specificity, and positive and negative predictive values were 100%, 80.7%, 16.6%, and 100%, respectively. Paraaortic lymph node metastasis in PET-CT was suspected in 10%. However, paraaortic lymph node metastasis was found in 6.7% in histopathologic analyses. The kappa value was 0.15. The sensitivity, specificity, and positive and negative predictive values of PET-CT for detecting paraaortic lymph node metastases were 100%, 93.7%, 66.6%, and 100%, respectively. Myometrial invasion and tumor diameter were the only important prognostic factors affecting SUVmax. Conclusion: According to our results, PET-CT has a limited role and diagnostic efficacy in endometrial cancer. The indications of FDG/PET-CT in endometrium cancer should be studied further and revised. PMID:29379661

  12. Laparoscopic Scar: a mimicker of Sister Mary Joseph's nodule on positron emission tomography/CT

    International Nuclear Information System (INIS)

    Setty, B.; Blake, M.A.; Holalkere, N.S.; Blaszkowsky, L.S.; Fischman, A.

    2006-01-01

    Positron emission tomography/CT is an established imaging method in the diagnosis and staging of cancers. 18 F -fluoro-2-deoxy-D-glucose (FDG) is the most commonly used radiotracer in positron emission tomography/CT. It is a tumour viability agent and usually its uptake within a lesion reflects the presence of a viable tumour tissue. However, false-positive FDG uptake is known to occur in benign processes of either inflammatory or infectious aetiology. We describe FDG uptake at the site of laparoscopic scar that mimicked Sister Mary Joseph's nodule in a patient with gastric adenocarcinoma. Here, the knowledge of the patient's history and subtle imaging findings helped in accurate staging of the patient. In this case report, we emphasize the value of the knowledge of the patient history and awareness of different pitfalls of FDG to achieve a correct diagnosis on positron emission tomography/CT

  13. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  14. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  15. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  16. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  17. Clinical impact of Positron Emission Tomography (PET) on oncological patients and their potentially application context

    International Nuclear Information System (INIS)

    Alonso, O.

    2006-01-01

    (PET) Positron Emission Tomography is a technique of nuclear medicine that has ability of detecting cancer through mechanisms based on molecular alterations of neoplastic processes. This review describes the PET Oncology applications and discusses the potential application of this technology in the sanitary and national academic framework . The most widely used in Oncology plotter is an analogue of laglucosa labelled with fluo: 18F-2-fluoro-2-Deoxy-D-glucose (FDG). In this way, the PET detects tumour retention of FDG, due to the highest glycolytic of cancer cells. In addition, the PET allow the study of the entire body at the same exploratory and some teams are coupled to systems of axial tomography (PET-CT). By ET-FDG, it is possible to diagnose, staging and restaged the majority of cancers, with diagnostic accuracy close to 90 per cent higher than the values provided by the conventional imaging techniques such. It is also possible to know early response to cancer treatments and obtain relevant medical prognosis information. (author) [es

  18. Simultaneous whole body (18)F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with (18)F-fluorodeoxyglucose positron emission tomography computed tomography.

    Science.gov (United States)

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-03-28

    To describe our preliminary experience with simultaneous whole body (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated (18)F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than

  19. Simultaneous whole body 18F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with 18F-fluorodeoxyglucose positron emission tomography computed tomography

    Science.gov (United States)

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-01-01

    AIM: To describe our preliminary experience with simultaneous whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. METHODS: This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated 18F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. RESULTS: A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was

  20. Imaging spectrum and pitfalls of ¹⁸F-fluorodeoxyglucose positron emission tomography/computed tomography in patients with tuberculosis.

    Science.gov (United States)

    Ito, Kimiteru; Morooka, Miyako; Minamimoto, Ryogo; Miyata, Yoko; Okasaki, Momoko; Kubota, Kazuo

    2013-08-01

    Mycobacterium tuberculosis (TB) is one of the most prominant diseases frequently causing false positive lesions in oncologic surveys using (18)F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT), since TB granulomas are composed of activated macrophages and lymphocytes with high affinity for glucose. These pitfalls of (18)F-FDG PET/CT are important for radiologists. Being familiar with (18)F-FDG images of TB could assist in preventing unfavorable clinical results based on misdiagnoses. In addition, (18)F-FDG PET/CT has the advantage of being able to screen the whole body, and can clearly detect harboring TB lesions as high uptake foci. This article details the spectrum and pitfalls of (18)F-FDG PET/CT imaging in TB.

  1. Positron emission tomography now and in the future

    International Nuclear Information System (INIS)

    Vaalburg, W.

    1987-01-01

    A survey is given of positron emission tomography used in nuclear medicine. The production of positron emitting radionuclides is discussed. The development of positron detectors is described. The application of positron emission tomography in cardiology, oncology and neurology is treated. The authors conclude that PET is a unique method to examine metabolic processes, although the method is still in its infancy. 7 refs.; 1 table

  2. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  3. Skeletal metastases from breast cancer: uptake of 18F-fluoride measured with positron emission tomography in correlation with CT

    International Nuclear Information System (INIS)

    Petren-Mallmin, M.; Andreasson, I.; Bergh, J.; Ljunggren, Oe.; Ahlstroem, H.; Antoni, G.; Laangstroem, B.; Bergstroem, M.

    1998-01-01

    Objective. To characterise the uptake of 18 F in skeletal metastases from breast cancer using positron emission tomography (PET) and to relate these findings to the appearance on CT. Patients and design. PET with 18 F and CT were performed in five patients with multiple skeletal metastases from breast cancer. The CT characteristics were analysed in areas with high uptake on the PET study. Dynamic PET imaging of the skeletal kinetics of the 18 F-fluoride ion were included. Results. The areas of abnormal high accumulation of 18 F correlated well with the pathological appearance on CT. Lytic as well as sclerotic lesions had markedly higher uptake than normal bone, with a 5-10 times higher transport rate constant for trapping of the tracer in the metastatic lesions than in normal bone. Conclusion. PET with 18 F-fluoride demonstrates very high uptake in lytic and sclerotic breast cancer metastases. (orig.)

  4. Simultaneous emission and transmission scanning in positron emission tomography

    International Nuclear Information System (INIS)

    Satoh, Tomohiko; Tanaka, Kazumi; Kitamura, Keishi; Amano, Masaharu; Miura, Shuichi

    2001-01-01

    Examination by PET (positron emission tomography) scanning, following the dosage of 2-deoxy- 18 F fluoro-D-glucose (FDG), is positively utilized for the diagnosis of cancers, rather than for the purpose of studies. This is because the examination by FDG-PET (PET scanning following the dosage of FDG) ensures higher efficiency in discrimination of cancers, than conventional CT and PET. The method of whole body scanning by PET scanning following the dosage of FDG is effectively utilized not only for discrimination cancers, but also for determining the degree of malignancy of tumors and evaluating the methods of treatment of cancers. In conventional methods for examining the degree of malignancy of tumors and evaluating the methods of cancer treatment, it is necessary to correct for the gamma-ray attenuation, which requires a longer time for examination, increasing the physical and psychological pains of the patients. We have installed the simultaneous emission and transmission scanning capability into the HEADTOME-V of the Shimadzu SET-2000W Series positron emission tomographic scanning instruments, to establish an instrument that permits FDG-PET whole body scanning in actual clinical fields, with minimized physical and psychological pains of patients concerned, yet ensuring an outstandingly high examination efficiency. This report also presents some data obtained by this newly developed instrument and those obtained in practical applications. (author)

  5. Higher fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) uptake in tuberculous compared to bacterial spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Bassetti, Matteo; Merelli, Maria; Della Siega, Paola; Righi, Elda [Santa Maria della Misericordia University Hospital, Infectious Diseases Division, Udine (Italy); Di Gregorio, Fernando [Santa Maria della Misericordia University Hospital, Microbiology Unit, Udine (Italy); Screm, Maria; Scarparo, Claudio [Santa Maria della Misericordia University Hospital, Radiology Unit, Udine (Italy)

    2017-06-15

    Tuberculous spondylodiscitis can be difficult to diagnose because of its nonspecific symptoms and the similarities with non-tubercular forms of spinal infection. Fluorine-18-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG PET-CT) is increasingly used for the diagnosis and monitoring of tubercular diseases. Retrospective, case-control study comparing tuberculous spondylodiscitis with biopsy-confirmed pyogenic spondylodiscitis in the period 2010-2012. Ten cases of tuberculous spondylodiscitis and 20 controls were included. Compared to pyogenic, tuberculous spondylodiscitis was more frequent in younger patients (P = 0.01) and was more often associated with thoraco-lumbar tract lesions (P = 0.01) and multiple vertebral involvement (P = 0.01). Significantly higher maximum standardized uptake values (SUV) at FDG-PET were displayed by tuberculous spondylodiscitis compared to controls (12.4 vs. 7.3, P = 0.003). SUV levels above 8 showed the highest value of specificity (0.80). Mean SUV reduction of 48% was detected for tuberculous spondylodiscitis at 1-month follow-up. Higher SUV levels at FDG-PET were detected in tuberculous compared with pyogenic spondylodiscitis. PET-CT use appeared useful in the disease follow-up after treatment initiation. (orig.)

  6. 18F-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    Science.gov (United States)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections. 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) scanning has been suggested as an alternative for the diagnosis and assessment of infectious processes. Hybrid 18F-FDG PET/CT has established the role of 18F-FDG PET for the assessment of suspected VPGI, providing accurate anatomic localization of the site of infection. However, there are no clear guidelines for the interpretation of the uptake patterns of 18F-FDG as clinical tool for VPGI. Based on the available literature it is suggested that a linear, diffuse, and homogeneous uptake should not be regarded as an infection whereas focal or heterogeneous uptake with a projection over the vessel on CT is highly suggestive of infection. Nevertheless, 18F-FDG PET and 18F-FDG PET/CT can play an important role in the detection of VPGI and monitoring response to treatment. However an accurate uptake and pattern recognition is warranted and cut-off uptake values and patterns need to be standardized before considering the technique to be the new standard. PMID:25210712

  7. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Mustafa Demir; Türkay Toklu; Mohammad Abuqbeitah; Hüseyin Çetin; H. Sezer Sezgin; Nami Yeyin; Kerim Sönmezoğlu

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated...

  8. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H. Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated asp...

  9. Positron emission tomography in the management of cervix cancer patients; Tomographie par emission de positons dans la prise en charge des cancers du col de l'uterus

    Energy Technology Data Exchange (ETDEWEB)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H. [Hopital d' Instruction des Armees du Val-de-Grace, Service de Medecine Nucleaire, 75 - Paris (France); Chargari, C.; Bauduceau, O. [Hopital d' Instruction des Armees du Val-de-Grace, Service de Radiotherapie, 75 - Paris (France)

    2009-10-15

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with {sup 18}F-fluoro-2-deoxy-D-glucose ({sup 18}F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  10. A meta-analysis of 18F-Fluoride positron emission tomography for assessment of metastatic bone tumor

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Morita, Satoshi; Taguri, Masataka

    2010-01-01

    The aim of this study was to assess the diagnostic performance of 18 F-Fluoride positron emission tomography (PET) or positron emission tomography/computed tomography (PET/CT) compared with bone scintigraphy (BS) planar or BS planar and single photon emission computed tomography (SPECT) in evaluating patients with metastatic bone tumor. We performed a meta-analysis of all available studies addressing the diagnostic accuracy of 18 F-Fluoride PET, 18 F-Fluoride PET/CT, BS planar, and BS planar and SPECT for detecting the metastatic bone tumor. We determined sensitivities and specificities across studies, calculated positive and negative likelihood ratios, and drew summary receiver operating characteristic curves using hierarchical regression models. We also compared the effective dose and cost-effectiveness estimated by data from the enrolled studies between 18 F-Fluoride PET or PET/CT and BS planar or BS planar and SPECT. When comparing all studies with data on 18 F-Fluoride PET or PET/CT, sensitivity and specificity were 96.2% [95% confidence interval (CI) 93.5-98.9%] and 98.5% (95% CI 97.0-100%), respectively, on a patient basis and 96.9% (95% CI 95.9-98.0%) and 98.0% (95% CI 97.1-98.9%), respectively, on a lesion basis. The Az values of 18 F-Fluoride PET or PET/CT were 0.986 for the patient basis and 0.905 for the lesion basis, whereas those of BS or BS and SPECT were 0.866 for the patient basis and 0.854 for the lesion basis. However, the estimated effective dose and average cost-effective ratio were poorer for 18 F-Fluoride PET or PET/CT than those of BS planar or BS planar and SPECT. 18 F-Fluoride PET or PET/CT has excellent diagnostic performance for the detection of metastatic bone tumor, but the estimated effective dose and average cost-effective ratio are at a disadvantage compared with BS planar or BS planar and SPECT. (author)

  11. Detecting Metastatic Bladder Cancer Using (18)F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Öztürk, Hakan

    2015-10-01

    The purpose of this study was to retrospectively investigate the contribution of (18)F-fluorodeoxyglucose-positron emission tomography/computed tomography ((18)F-FDG-PET/CT) to detection of metastatic bladder cancer. The present study included 79 patients (69 men and 10 women) undergoing (18)F-FDG-PET/CT upon suspicion of metastatic bladder cancer between July 2007 and April 2013. The mean age was 66.1 years with a standard deviation of 10.7 years (range, 21 to 85 years). Patients were required to fast for 6 hours prior to scanning, and whole-body PET scanning from the skull base to the upper thighs was performed approximately 1 hour after intravenous injection of 555 MBq of (18)F-FDG. Whole body CT scanning was performed in the cranio-caudal direction. FDG-PET images were reconstructed using CT data for attenuation correction. Suspicious recurrent or metastatic lesions were confirmed by histopathology or clinical follow-up. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of (18)F-FDG-PET/CT were 89%, 78%, 90%, 75%, and 86%, respectively. (18)F-FDG-PET/CT can detect metastases with high sensitivity and positive predictive values in patients with metastatic bladder carcinoma.

  12. The metabolism of the human brain studied with positron emission tomography

    International Nuclear Information System (INIS)

    Greitz, T.; Ingvar, D.H.; Widen, L.

    1985-01-01

    This volume presents coverage of the use of positron emission tomography (PET) to study the human brain. The contributors assess new developments in high-resolution positron emission tomography, cyclotrons, radiochemistry, and tracer kinetic models, and explore the use of PET in brain energy metabolism, blood flow, and protein synthesis measurements, receptor analysis, and pH determinations, In addition, they discuss the relevance and applications of positron emission tomography from the perspectives of physiology, neurology, and psychiatry

  13. Positron emission tomography/computed tomography--imaging protocols, artifacts, and pitfalls.

    Science.gov (United States)

    Bockisch, Andreas; Beyer, Thomas; Antoch, Gerald; Freudenberg, Lutz S; Kühl, Hilmar; Debatin, Jörg F; Müller, Stefan P

    2004-01-01

    There has been a longstanding interest in fused images of anatomical information, such as that provided by computed tomography (CT) or magnetic resonance imaging (MRI) systems, with biological information obtainable by positron emission tomography (PET). The near-simultaneous data acquisition in a fixed combination of a PET and a CT scanner in a combined PET/CT imaging system minimizes spatial and temporal mismatches between the modalities by eliminating the need to move the patient in between exams. In addition, using the fast CT scan for PET attenuation correction, the duration of the examination is significantly reduced compared to standalone PET imaging with standard rod-transmission sources. The main source of artifacts arises from the use of the CT-data for scatter and attenuation correction of the PET images. Today, CT reconstruction algorithms cannot account for the presence of metal implants, such as dental fillings or prostheses, properly, thus resulting in streak artifacts, which are propagated into the PET image by the attenuation correction. The transformation of attenuation coefficients at X-ray energies to those at 511 keV works well for soft tissues, bone, and air, but again is insufficient for dense CT contrast agents, such as iodine or barium. Finally, mismatches, for example, due to uncoordinated respiration result in incorrect attenuation-corrected PET images. These artifacts, however, can be minimized or avoided prospectively by careful acquisition protocol considerations. In doubt, the uncorrected images almost always allow discrimination between true and artificial finding. PET/CT has to be integrated into the diagnostic workflow for harvesting the full potential of the new modality. In particular, the diagnostic power of both, the CT and the PET within the combination must not be underestimated. By combining multiple diagnostic studies within a single examination, significant logistic advantages can be expected if the combined PET/CT

  14. Contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography in solid pseudopapillary neoplasm of the pancreas

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Lakshmanan, Ramesh Kumar; Sonik, Bhavay; Padmavathy, Rajagopalan; Gunaseelan, Rajamani Emmanuel

    2016-01-01

    Solid pseudopapillary neoplasm (SPN) of the pancreas is a rare pancreatic tumor with low malignant potential. It occurs characteristically more often in young women. Radiological and pathological studies have revealed that the tumor is quite different from other pancreatic tumors. Limited information is available in the literature reporting their accumulation of fluorine- 18 fluorodeoxyglucose ( 18 F-FDG) in positron emission tomography/computed tomography (PET/CT). Here, we report a case of pancreatic SPN imaged with contrast-enhanced FDG PET/CT. A percutaneous fine needle aspiration from the metabolically active lesion revealed SPN, and it was confirmed with histopathological results. Recurrence or metastasis was not found after 7 months of follow-up

  15. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  16. In Vivo Treatment Sensitivity Testing With Positron Emission Tomography/Computed Tomography After One Cycle of Chemotherapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Kostakoglu, Lale; Zaucha, Jan Maciej

    2014-01-01

    PURPOSE: Negative [(18)F]fluorodeoxyglucose (FDG) -positron emission tomography (PET)/computed tomography (CT) after two cycles of chemotherapy indicates a favorable prognosis in Hodgkin lymphoma (HL). We hypothesized that the negative predictive value would be even higher in patients responding....... In the absence of precise pretherapeutic predictive markers, PET1 is the best method for response-adapted strategies designed to select patients for less intensive treatment....

  17. Diagnostic performance of fluorodeoxyglucose positron emission tomography/magnetic resonance imaging fusion images of gynecological malignant tumors. Comparison with positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Nakajo, Kazuya; Tatsumi, Mitsuaki; Inoue, Atsuo

    2010-01-01

    We compared the diagnostic accuracy of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and PET/magnetic resonance imaging (MRI) fusion images for gynecological malignancies. A total of 31 patients with gynecological malignancies were enrolled. FDG-PET images were fused to CT, T1- and T2-weighted images (T1WI, T2WI). PET-MRI fusion was performed semiautomatically. We performed three types of evaluation to demonstrate the usefulness of PET/MRI fusion images in comparison with that of inline PET/CT as follows: depiction of the uterus and the ovarian lesions on CT or MRI mapping images (first evaluation); additional information for lesion localization with PET and mapping images (second evaluation); and the image quality of fusion on interpretation (third evaluation). For the first evaluation, the score for T2WI (4.68±0.65) was significantly higher than that for CT (3.54±1.02) or T1WI (3.71±0.97) (P<0.01). For the second evaluation, the scores for the localization of FDG accumulation showing that T2WI (2.74±0.57) provided significantly more additional information for the identification of anatomical sites of FDG accumulation than did CT (2.06±0.68) or T1WI (2.23±0.61) (P<0.01). For the third evaluation, the three-point rating scale for the patient group as a whole demonstrated that PET/T2WI (2.72±0.54) localized the lesion significantly more convincingly than PET/CT (2.23±0.50) or PET/T1WI (2.29±0.53) (P<0.01). PET/T2WI fusion images are superior for the detection and localization of gynecological malignancies. (author)

  18. 77 FR 21783 - Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography...

    Science.gov (United States)

    2012-04-11

    ...] Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography Drugs... Aseptic Preparations for Positron Emission Tomography (PET) Drugs.'' This guidance is intended to help... Preparations for Positron Emission Tomography (PET) Drugs.'' Most PET drugs are designed for parenteral...

  19. 18F-FDG positron emission tomography/computed tomography in infective endocarditis.

    Science.gov (United States)

    Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla

    2017-02-01

    The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.

  20. Cobalt-55 positron emission tomography in traumatic brain injury : A pilot study

    NARCIS (Netherlands)

    Jansen, HML; vanderNaalt, J; vanZomeren, AH; Paans, AMJ; VeenmavanderDuin, L; Hew, JM; Pruim, J; Minderhoud, JM; Korf, J

    Traumatic brain injury is usually assessed with the Glasgow coma scale (GCS), CT, or MRI. After such injury, the injured brain tissue is characterised by calcium mediated neuronal damage and inflammation. Positron emission tomography with the isotope cobalt-55 (Go-PET) as a calcium tracer enables

  1. Impact of 18-fluorodeoxyglucose positron emission tomography on computed tomography defined target volumes in radiation treatment planning of esophageal cancer : reduction in geographic misses with equal inter-observer variability

    NARCIS (Netherlands)

    Schreurs, Liesbeth; Busz, D. M.; Paardekooper, G. M. R. M.; Beukema, J. C.; Jager, P. L.; Van der Jagt, E. J.; van Dam, G. M.; Groen, H.; Plukker, J. Th. M.; Langendijk, J. A.

    P>Target volume definition in modern radiotherapy is based on planning computed tomography (CT). So far, 18-fluorodeoxyglucose positron emission tomography (FDG-PET) has not been included in planning modality in volume definition of esophageal cancer. This study evaluates fusion of FDG-PET and CT in

  2. Pitfalls of fluorodeoxyglucose positron-emission tomography-CT in tuberculosis mimicking malignancy in 60 patients

    International Nuclear Information System (INIS)

    Wang Xinlu; Yin Jilin; Zhang Jinhe; Ou Yangxi; Zhou Zheng; Quan Jiangtao; Zhang Weibiao; Zheng Hui

    2013-01-01

    Objective: To analyze the pitfalls of "1"8F fluorodeoxyglucose (FDG) positron emission tomography/computer tomography (PET-CT) scan in the diagnosis of 60 patients of tuberculosis mimicking malignancy. Methods: The study included 60 patients with PET-CT diagnosis of probable malignancy. Fifty patients were proved to be tuberculosis by pathological examinations and 10 were diagnosed by clinical followup. The images of whole body were acquired at 60 min after administration of 222-555 MBq "1"8F-FDG. The PET-CT imaging characteristics and clinical data, including lesion size, distribution, standardized uptake value (SUV) were retrospectively analyzed. After the whole body scan of PET-CT, each patient had a chest spiral CT scan for detailed observation of lung lesions. Contrast enhanced CT (CECT) was performed in 8 patients. Results: (1)Thirty patients were misdiagnosed as lung cancer, 14 patients as malignant lymphoma, 6 patients as malignant mesothelioma, 3 as intestine carcinoma, 2 as bone malignancy, 1 patient as hepatocarcinoma, spleen malignancy, ovarian cancer, laryngocarcinoma and nasopharyngeal carcinoma respectively. (2) 90.9% (20/22) of patients showed normal level of serum CEA and 100% (13/13) of patients showed normal level of CA199. Increasing serum CA125 was found in all patients (6/6) with active TB patients accompanied with ascites, pleural fluid and (or) pericardial effusion. (3) 93.3% (28/30) active tuberculosis showed accumulated "1"8F-FDG which was incorrectly interpreted as malignancy. The most common sites of TB lymphadenopathy were bilateral cervical tissues, which was accounted for 85.7% (12/14). CECT revealed characteristics of peripheral enhancement and central necrosis in tubercular lymphadenopathy, which was 87.5% (7/8). Conclusions: The diverse manifestations of TB on imaging and high uptake of "1"8F-FDG on PET imaging result in misdiagnosis of malignancy. It is important for radiologists and nuclear medicine physicians to identify the

  3. Positron emission tomography. Basic principles

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Massardo, Teresa; Gonzalez, Patricio

    2001-01-01

    The basic principles of positron emission tomography (PET) technique are reviewed. lt allows to obtain functional images from gamma rays produced by annihilation of a positron, a positive beta particle. This paper analyzes positron emitters production in a cyclotron, its general mechanisms, and the various detection systems. The most important clinical applications are also mentioned, related to oncological uses of fluor-l8-deoxyglucose

  4. Para neoplastic syndromes: Usefulness of 18F-fluoro-deoxy-glucose (F.D.G.) positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Banayan, S.; Janier, M.; Guillerma-Zucchi, N.; Billotey, C.; Ninet, J.; Delmas, P.; Thivolet, C.; Pellet, O.

    2008-01-01

    Background We evaluated the performance of 18 F-fluorodeoxyglucose ( 18 F.D.G.) positron emission tomography (PET) in the diagnosis of underlying malignancy in cases of suspected para neoplastic syndrome (P.S.). Methods 18 F.D.G.-PET was performed in 31 patients, clinically suspected to have P.S.. The P.S. were 34, among which 12 neurological diseases, eight endocrine, seven rheumatological, one dermatological and six vascular. We compared computed tomography (CT), iodine-enhanced most of the time, and 18 F.D.G.-PET reports to clinicians definitive conclusion at the end of the work-up and a follow-up period of, at least, two months. Results We obtained a histological diagnosis of cancer for ten patients, but could only identify the primary site of malignancy for nine of them. 18 F.D.G.-PET showed six primary sites among which three were not seen on CT. CT disclosed four primary sites, among which one was not seen on 18 F.D.G.-PET. In one case, 18 F.D.G.-PET disclosed regional lymph node metastases whereas these were not identified by CT. Eleven non-neoplastic causes were evidenced, among which 18 F.D.G.-PET played a major role in three cases. Ten causes were still undetermined at the end of the study. Conclusion Whole-body 18 F.D.G.-PET study plays an important role in the identification of underlying malignancy in clinically suspected para neoplastic syndromes; either by identifying the primary tumor or by directing biopsy of metastases. Furthermore, it can identify non-neoplastic causes. (authors)

  5. Use of positron emission tomography in colorectal cancer; Uso de la tomografia de emision de positrones en el cancer colorrectal

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez E, Patricio; Jofre E, Josefina; Massardo V, Teresa; Humeres, Pamela; Canessa G, Jose; Sierralta C, Paulina [Hospital Militar de Santiago, Medicina Nuclear, Centro PET de Imagenes Moleculares, Santiago (Chile)

    2002-07-01

    The value of PET (Positron Emission Tomography) in colorectal cancer is presented. PET is a novel technique that uses F-18-FDG (fluorodeoxiglucose) to assess glucose metabolism by whole body imaging. It has been demonstrated that malignant cells have both increase of glucose uptake and utilization. In colorectal cancer, PET is indicated for staging, assess recurrence, liver metastasis and treatment follow-up. PET is more sensitive and specific than CT (Computed Tomography) and is cost effective. In 30% of cases PET may change patient management, avoiding unnecessary procedures (au)

  6. Lynch Syndrome Associated Colon Adenocarcinoma Resembling Lymphoma on Fluoro-Deoxyglucose-Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Aparici, Carina Mari; Win, Aung Zaw

    2015-01-01

    The patient was a 46-year-old Asian male diagnosed with lynch syndrome associated colon adenocarcinoma in the right ascending colon. A presurgical staging 18-fluoro-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) found increased metabolic activity in the cervical, axillary, mediastinal, supraclavicular, para-aortic and mesenteric lymph nodes. This pattern of metastasis was very unusual for lynch syndrome associated colon adenocarcinoma and the involvement of those lymph nodes resembles the pattern of spread of lymphoma. He underwent right hemicolectomy and he was subsequently treated with 12 cycles of folinic acid (leucovorin), fluorouracil (5-FU), irinotecan. A restaging FDG-PET/CT at the end of the chemotherapy showed interval decrease in size and metabolic activity in the affected lymph nodes. FDG-PET/CT is a useful imaging modality in following-up the treatment response in colon adenocarcinoma

  7. Decision logic for retreatment of asymptomatic lung cancer recurrence based on positron emission tomography findings

    International Nuclear Information System (INIS)

    Frank, Albert; Lefkowitz, David; Jaeger, Stanley; Gobar, Lisa; Sunderland, John; Gupta, Naresh; Scott, Walter; Mailliard, James; Lynch, Henry; Bishop, John; Thorpe, Patricia; Dewan, Naresh

    1995-01-01

    Purpose: The purpose of the study was to determine if Positron emission tomography (PET) 2-[F-18] fluoro-2-deoxy-D-glucose (FDG) imaging could detect subclinical local lung cancer recurrence and whether retreatment of such recurrence was feasible and beneficial. Methods and Materials: Twenty patients with biopsy proven lung cancer were studied with Positron emission tomography for the purpose of detecting subclinical lung cancer recurrence over a period of 4.25 years. All patients were treated with external radiation as part or all of their therapy. Twenty patients had baseline PET and computed tomography (CT) studies for comparison with later studies. Surviving patients had a total of 40 sequential PET scans and 35 CT scans. The follow-up interval ranged from 5 to 40 months posttreatment. The differential uptake ratio (DUR) was determined for regions of interest of increased FDG uptake. Results: The median DUR value of the 20 baseline PET studies was 5.59. The DUR value of greater than 3 was empirically selected as being positive for tumor detection. On baseline studies, PET had a 100% correlation with the CT findings in regard to detection of the site of primary tumor involvement. Four of 20 patients showed areas of discordance in the mediastinal and hilar areas on initial PET and CT studies. Seven of 17 patients showed discordant posttreatment PET-CT findings. Two false positive PET studies were due to radiation pneumonitis and one to macrophage glycolysis in tumor necrosis. For detection of asymptomatic tumor recurrence, analysis of sequential PET and CT studies, biopsy results, and the patient's clinical course suggested that PET had a sensitivity of 100%, specificity of 89.3%, and accuracy of 92.5%. Computerized Tomography was found to have a sensitivity of 67%, specificity of 85%, and accuracy of 82% for detection of such early-stage recurrence. Five patients went on to have retreatment with external irradiation based upon the PET evidence. Four retreated

  8. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  9. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  10. Effective dose to staff members in a positron emission tomography/CT facility using zirconium-89

    Science.gov (United States)

    2013-01-01

    Objective: Positron emission tomography (PET) using zirconium-89 (89Zr) is complicated by its complex decay scheme. In this study, we quantified the effective dose from 89Zr and compared it with fluorine-18 fludeoxyglucose (18F-FDG). Methods: Effective dose distribution in a PET/CT facility in Riyadh was calculated by Monte Carlo simulations using MCNPX. The positron bremsstrahlung, the annihilation photons, the delayed gammas from 89Zr and those emissions from 18F-FDG were modelled in the simulations but low-energy characteristic X-rays were ignored. Results: On the basis of injected activity, the dose from 89Zr was higher than that of 18F-FDG. However, the dose per scan from 89Zr became less than that from 18F-FDG near the patient, owing to the difference in injected activities. In the corridor and control rooms, the 89Zr dose was much higher than 18F-FDG, owing to the difference in attenuation by the shielding materials. Conclusion: The presence of the high-energy photons from 89Zr-labelled immuno-PET radiopharmaceuticals causes a significantly higher effective dose than 18F-FDG to the staff outside the patient room. Conversely, despite the low administered activity of 89Zr, it gives rise to a comparable or even lower dose than 18F-FDG to the staff near the patient. This interesting result raises apparently contradictory implications in the radiation protection considerations of a PET/CT facility. Advances in knowledge: To the best of our knowledge, radiation exposure to staff and public in the PET/CT unit using 89Zr has not been investigated. The ultimate output of this study will lead to the optimal design of the facility for routine use of 89Zr. PMID:23934963

  11. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    , primarily by providing confirmation of the absence of metastases. To place the size and site of a malignant growth computed tomography will still be necessary in future. The positron emission tomography should not replace computed tomography for the diagnosis of malignant tumors at head and neck, but shows some utility where used in conjunction. The new technology, PET-CT, has since been used in routine examinations, and shows promise of better performance.

  12. Malaria masquerading as relapse of Hodgkin's lymphoma on contrast enhanced 18F-fluorodeoxyglucose positron emission tomography/computed tomography: A diagnostic dilemma

    International Nuclear Information System (INIS)

    Jeph, Sunil; Thakur, Kamia; Shamim, Shamim Ahmed; Aggarwal, Ajay

    2014-01-01

    18 Flurodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) is nowadays routinely used in management of lymphoma patients. We here present a case of Hodgkin's lymphoma which showed 18 F-FDG avid splenomegaly on PET/CT done for clinically suspected relapse. Further evaluation by peripheral smear examination revealed malaria. The patient was then started on anti-malarial medications and follow-up PET/CT revealed resolution of hypermetabolic splenomegaly. This report highlights that in endemic regions malaria can cause 18 F-FDG avid splenomegaly and might mimic relapse of lymphoma

  13. Initial staging of Hodgkin's disease: role of contrast-enhanced 18F FDG PET/CT.

    Science.gov (United States)

    Chiaravalloti, Agostino; Danieli, Roberta; Caracciolo, Cristiana Ragano; Travascio, Laura; Cantonetti, Maria; Gallamini, Andrea; Guazzaroni, Manlio; Orlacchio, Antonio; Simonetti, Giovanni; Schillaci, Orazio

    2014-08-01

    The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin's disease (HD).Forty patients (18 men and 22 women, mean age 30 ± 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an unenhanced low-dose computed tomography for attenuation correction with positron emission tomography acquisition and a ceCT, performed at the end of the PET/ldCT scan, in the same exam session. A detailed datasheet was generated for illness locations for separate imaging modality comparison and then merged in order to compare the separate imaging method results (PET/ldCT and ceCT) versus merged results positron emission tomography/contrast-enhanced computed tomography (PET/ceCT). The nodal and extranodal lesions detected by each technique were then compared with follow-up data that served as the reference standard.No significant differences were found at staging between PET/ldCT and PET/ceCT in our series. One hundred and eighty four stations of nodal involvement have been found with no differences in both modalities. Extranodal involvement was identified in 26 sites by PET/ldCT and in 28 by PET/ceCT. We did not find significant differences concerning the stage (Ann Arbor).Our study shows a good concordance and conjunction between PET/ldCT and ceCT in both nodal and extranodal sites in the initial staging of HD, suggesting that PET/ldCT could suffice in most of these patients.

  14. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  15. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  16. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  17. Therapeutic impact of [18F]fluoride positron-emission tomography/computed tomography on patients with unclear foot pain

    International Nuclear Information System (INIS)

    Fischer, Dorothee Rita; Hesselmann, Rolf; Johayem, Anass; Hany, Thomas F.; Schulthess, Gustav K. von; Strobel, Klaus; Maquieira, Gerardo J.; Espinosa, Norman; Zanetti, Marco

    2010-01-01

    To evaluate the therapeutic impact of [ 18 F]fluoride positron-emission tomography/computed tomography ([ 18 F]fluoride PET/CT) imaging on patients with unclear foot pain. Twenty-eight patients were prospectively included in this study. Therapeutic management was defined by two experienced dedicated foot surgeons before and after [ 18 F]fluoride PET/CT imaging. Twenty-six patients underwent cross-sectional imaging [CT, magnetic resonance (MR)] prior to PET/CT. A retrospective analysis of the magnetic resonance imaging (MRI) diagnoses was performed when a therapy change occurred after PET/CT imaging. In 13/28 (46%) patients therapeutic management was changed due to PET/CT results. Management changes occurred in patients with the following diagnoses: os trigonum syndrome; sinus tarsi syndrome; os tibiale externum syndrome; osteoarthritis of several joints; non-consolidated fragments; calcaneo-navicular coalition; plantar fasciitis; insertional tendinopathy; suggestion of periostitis; neoarticulations between metatarsal bones. Os trigonum, os tibiale externum, subtalar osteoarthritis and plantar fasciitis were only seen to be active on PET/CT images but not on MR images. [ 18 F]fluoride PET/CT has a substantial therapeutic impact on management in patients with unclear foot pain. (orig.)

  18. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d'Amore, Francesco; Mylam, Karen Juul

    2012-01-01

    PURPOSETo investigate whether bone marrow biopsy (BMB) adds useful information to [(18)F]fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) staging in patients with Hodgkin lymphoma (HL). PATIENTS AND METHODSNewly diagnosed patients with HL undergoing a pretherapeu...

  19. Positron emission tomography with 68Ga-EDTA in the diagnosis and localization of CSF fistulas

    International Nuclear Information System (INIS)

    Bergstrand, G.; Bergstroem, M.; Eriksson, L.; Edner, G.; Widen, L.

    1982-01-01

    Five patients with cerebrospinal fluid (CSF) rhinorrhea were investigated with computed tomography (CT) and positron emission tomography (PET) to localize the site of a CSF fistula. After intrathecal injection of 10 MBq of 68 Ga-EDTA, radioactivity was demonstrated in the basal cisterns. In three cases, the site of the fistula was visualized with PET. It is not always possible to demonstrate a CSF leakage with CT cisternography (CTC) using metrizamide, particularly in cases with minute fistulas or intermittent CSF rhinorrhea. With further experience and improved PET techniques, it may be possible to detect even very small fistulas

  20. (18)F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Malignancies of the Thyroid and in Head and Neck Squamous Cell Carcinoma

    DEFF Research Database (Denmark)

    Lauridsen, Jeppe Kiilerich; Rohde, Max; Thomassen, Anders

    2015-01-01

    18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) is a valuable diagnostic tool in a spectrum of malignant and benign conditions, because of a high sensitivity to detect even very small lesions with increased metabolism. This review focuses on the use of FDG...

  1. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  2. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  3. 18 F-sodium fluoride positron emission tomography of the equine distal limb: Exploratory study in three horses.

    Science.gov (United States)

    Spriet, M; Espinosa, P; Kyme, A Z; Phillips, K L; Katzman, S A; Galuppo, L D; Stepanov, P; Beylin, D

    2018-01-01

    Positron emission tomography (PET) is a cross-sectional, functional imaging modality that has recently become available to the horse. The use of 18 F-sodium fluoride ( 18 F-NaF), a PET bone tracer, has not previously been reported in this species. To assess the feasibility of 18 F-NaF PET in the equine distal limb and explore possible applications in the horse in comparison with other imaging modalities. Exploratory descriptive study involving three research horses. Horses were placed under general anaesthesia prior to intravenous (i.v.) administration of 1.5 MBq/kg of 18 F-NaF. Positron emission tomography imaging of both front feet and fetlocks was performed using a portable scanner. Computed tomography (CT) of the distal limb was performed under a separate anaesthetic episode. Bone scintigraphy and magnetic resonance imaging (MRI) were subsequently performed under standing sedation. Images obtained from PET and other imaging modalities were independently assessed and the results correlated. Positron emission tomography images were obtained without complication. The radiation exposure rate was similar to equine bone scintigraphy. Positron emission tomography detected focal 18 F-NaF uptake in areas where other imaging modalities did not identify any abnormalities. This included sites of ligamentous attachment, subchondral compact bone plate and the flexor cortex of the navicular bone. 18 F-NaF uptake was identified in some, but not all, osseous fragments and areas of osseous formation, suggesting a distinction between active and inactive lesions. A small number of horses were included and histopathology was not available. 18 F-NaF PET imaging of the equine distal limb provides useful additional information when compared with CT, MRI and scintigraphy and has the potential for both research and clinical applications in the horse. The Summary is available in Chinese - see Supporting information. © 2017 EVJ Ltd.

  4. Magnetic resonance imaging-guided attenuation correction of positron emission tomography data in PET/MRI

    OpenAIRE

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-01-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined positron emission tomography/magnetic resonance imaging (PET/MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients (LACs) of the tissues and other components located in the PET field of view (FoV). MR-AC methods can be divided into three main categories: segmentation-, atlas- and PET-based. This review aims to...

  5. Development of ''Eminence STARGATE'' PET/CT system

    International Nuclear Information System (INIS)

    Okazaki, Masato; Inoue, Yoshihiro; Amano, Masaharu

    2009-01-01

    A PET/CT system, the combination of a PET (Positron Emission Tomography) system with an X-ray CT system, has been widely used in recent years. Our newly developed ''Eminence STARGATE'' PET/CT system allows the PET gantry and the X-ray CT gantry to move independently. This advantage provides high flexibility for PET examination and X-ray CT examination and also eases a patient's psychological anxiety about closed spaces. The system has a 16-slice X-ray CT scanner. (author)

  6. Radiopharmaceutical chemistry for positron emission tomography

    NARCIS (Netherlands)

    Elsinga, PH

    Radiopharmaceutical chemistry includes the selection, preparation, and preclinical evaluation of radiolabeled compounds. This paper describes selection criteria for candidates for positron emission tomography (PET) investigations. Practical aspects of nucleophilic and electrophilic

  7. Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning

    DEFF Research Database (Denmark)

    Ashraf, H; Dirksen, A; Jakobsen, Annika Loft

    2011-01-01

    In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules.......In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules....

  8. Relevance of positron emission tomography (PET) in oncology

    International Nuclear Information System (INIS)

    Weber, W.A.; Avril, N.; Schwaiger, M.

    1999-01-01

    Background: The clinical use of positron emission tomography (PET) for detection and staging of malignant tumors is rapidly increasing. Furthermore, encouraging results for monitoring the effects of radio- and chemotherapy have been reported. Methods: This review describes the technical principles of PET and the biological characteristics of tracers used in oncological research and patient studies. The results of clinical studies published in peer reviewed journals during the last 5 years are summarized and clinical indications for PET scans in various tumor types are discussed. Results and Conclusions: Numerous studies have documented the high diagnostic accuracy of PET studies using the glucose analogue F-18-fluordeoxyglucose (FDG-PET) for detection and staging of malignant tumors. In this field, FDG-PET has been particularly successful in lung cancer, colorectal cancer, malignant lymphoma and melanoma. Furthermore, FDG-PET has often proven to be superior to morphological imaging techniques for differentation of tumor recurrence from scar tissue. Due to the high glucose utilization of normal gray matter radiolabeled amino-acids like C-11-methionine are superior to FDG for detection and delineation of brain tumors by PET. In the future, more specific markers of tumor cell proliferation and gene expression may allow the application of PET not only for dianostic imaging also but for non-invasive biological characterization of malignant tumors and early monitoring of therapeutic interventions. (orig.) [de

  9. PET/CT applications in oncology

    International Nuclear Information System (INIS)

    Oliva González, Juan Perfecto; Martínez Ramírez, Aldo; Baum, Richard Paul

    2017-01-01

    PET means Positron Emission Tomography, it is a nuclear medicine technique in which radiopharmaceuticals labeled with positron emitters are used to obtain biochemical-metabolic images of the human body. The use of PET / CT contributes to obtain multimodal images that combine anatomical and metabolic information, allowing a more reliable diagnosis of a tumor or local or distant metastases in an organ or tissue. Other multimodal devices combine metabolic imaging with nuclear magnetic resonance. PET/CT is mainly used in Oncology (85-90%), Neurology, Cardiology, Inflammation and Infection although it is currently also used in different medical and surgical pathologies. The present work is aimed at showing what PET/CT is and how useful it is in Oncology. (author)

  10. New developments in molecular imaging: positron emission tomography time-of-flight (TOF-PET)

    International Nuclear Information System (INIS)

    Aguilar, P.; Couce, B.; Iglesias, A.; Lois, C.

    2011-01-01

    Positron Emission tomography (PET) in increasingly being used in oncology for the diagnosis and staging of disease, as well as in monitoring response to therapy. One of the last advances in PET is the incorporation of Time-of-Flight (TOF) information, which improves the tomographic reconstruction process and subsequently the quality of the final image. In this work, we explain the principles of PET and the fundamentals of TOF-PET. Clinical images are shown in order to illustrate how TOF-PET improves the detectability of small lesions, particularly in patients with high body mass index. (Author) 20 refs

  11. 77 FR 71802 - Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Science.gov (United States)

    2012-12-04

    ... Positron Emission Tomography (PET) Drugs.'' The guidance is intended to assist manufacturers of PET drugs... one self-addressed adhesive label to assist that office in processing your requests. See the... ``Investigational New Drug Applications for Positron Emission Tomography (PET) Drugs.'' The guidance summarizes the...

  12. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    Science.gov (United States)

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  13. The Medical Case for a Positron Emission Tomography and X-ray Computed Tomography Combined Service in Oman.

    Science.gov (United States)

    Al-Bulushi, Naima K; Bailey, Dale; Mariani, Giuliano

    2013-11-01

    The value of a positron emission tomography and X-ray computed tomography (PET/CT) combined service in terms of diagnostic accuracy, cost-effectiveness and impact on clinical decision-making is well-documented in the literature. Its role in the management of patients presenting with cancer is shifting from early staging and restaging to the early assessment of the treatment response. Currently, the application of PET/CT has extended to non-oncological specialties-mainly neurology, cardiology and rheumatology. A further emerging application for PET/CT is the imaging of infection/inflammation. This article illustrates some of the PET/CT applications in both oncological and non-oncological disorders. In view of the absence of this modality in Oman, this article aims to increase the awareness of the importance of these imaging modalities and their significant impact on diagnosis and management in both oncological and non-oncological specialties for patients of all age groups as well as the decision-makers.

  14. Prostate cancer nodal oligometastasis accurately assessed using prostate-specific membrane antigen positron emission tomography-computed tomography and confirmed histologically following robotic-assisted lymph node dissection.

    Science.gov (United States)

    O'Kane, Dermot B; Lawrentschuk, Nathan; Bolton, Damien M

    2016-01-01

    We herein present a case of a 76-year-old gentleman, where prostate-specific membrane antigen positron emission tomography-computed tomography (PSMA PET-CT) was used to accurately detect prostate cancer (PCa), pelvic lymph node (LN) metastasis in the setting of biochemical recurrence following definitive treatment for PCa. The positive PSMA PET-CT result was confirmed with histological examination of the involved pelvic LNs following pelvic LN dissection.

  15. Prostate cancer nodal oligometastasis accurately assessed using prostate-specific membrane antigen positron emission tomography-computed tomography and confirmed histologically following robotic-assisted lymph node dissection

    Directory of Open Access Journals (Sweden)

    Dermot B O′Kane

    2016-01-01

    Full Text Available We herein present a case of a 76-year-old gentleman, where prostate-specific membrane antigen positron emission tomography-computed tomography (PSMA PET-CT was used to accurately detect prostate cancer (PCa, pelvic lymph node (LN metastasis in the setting of biochemical recurrence following definitive treatment for PCa. The positive PSMA PET-CT result was confirmed with histological examination of the involved pelvic LNs following pelvic LN dissection.

  16. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  17. Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy

    NARCIS (Netherlands)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A; Michaud, Susan; Loeffler, Jay S; DeLaney, Thomas F; Liebsch, Norbert J; Munzenrider, John E; Fischman, Alan J; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    PURPOSE: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. METHODS AND MATERIALS: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3

  18. An Assessment of Early Response to Targeted Therapy via Molecular Imaging: A Pilot Study of 3′-deoxy-3′[(18F]-Fluorothymidine Positron Emission Tomography 18F-FLT PET/CT in Prostate Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Kalevi Kairemo

    2017-04-01

    Full Text Available Fluorothymidine is a thymidine analog labeled with fluorine-18 fluorothymidine for positron emission tomography (18F-FLT-PET imaging. Thymidine is a nucleic acid that is used to build DNA. Fluorine-18 fluorothymidine (18F-FLT utilizes the same metabolic pathway as does thymidine but has a very low incidence of being incorporated into the DNA (<1%. 18F-FLT-PET could have a role in the evaluation of response to targeted therapy. We present here a pilot study where we investigated cellular metabolism and proliferation in patients with prostate cancer before and after targeted therapy. Seven patients with Stage IV prostate adenocarcinoma, candidates for targeted therapy inhibiting the hepatocyte growth factor/tyrosine-protein kinase Met (HGF/C-MET pathway, were included in this study. The HGF/C-MET pathway is implicated in prostate cancer progression, and an evaluation of the inhibition of this pathway could be valuable. 18F-FLT was performed at baseline and within four weeks post-therapy. Tumor response was assessed semi-quantitatively and using visual response criteria. The range of SUVmax for 18F-FLT at baseline in the prostate varied from 2.5 to 4.2. This study demonstrated that 18F-FLT with positron emission tomography/computerized tomography (18F-FLT PET/CT had only limited applications in the early response evaluation of prostate cancer. 18F-FLT PET/CT may have some utility in the assessment of response in lymph node disease. However, 18F-FLT PET/CT was not found to be useful in the evaluation of the prostate bed, metastatic skeletal disease, and liver disease.

  19. Appropriateness criteria of FDG PET/CT in oncology

    International Nuclear Information System (INIS)

    Agrawal, Archi; Rangarajan, Venkatesh

    2015-01-01

    18 Fluorine-2-fluoro-2-Deoxy-d-glucose ( 18 F-FDG) positron emission tomography/computerized tomography (PET/CT) is a well-established functional imaging method widely used in oncology. In this article, we have incorporated the various indications for 18 FDG PET/CT in oncology based on available evidence and current guidelines. Growing body of evidence for use of 18 FDG PET/CT in select tumors is also discussed. This article attempts to give the reader an overview of the appropriateness of using 18 F-FDG PET/CT in various malignancies

  20. Molecular pathology in vulnerable carotid plaques: correlation with [18]-fluorodeoxyglucose positron emission tomography (FDG-PET)

    DEFF Research Database (Denmark)

    Graebe, M; Pedersen, Sune Folke; Borgwardt, L

    2008-01-01

    OBJECTIVES: Atherosclerosis is recognised as an inflammatory disease, and new diagnostic tools are warranted to evaluate plaque inflammatory activity and risk of cardiovascular events. We investigated [18]-fluorodeoxyglucose (FDG) uptake in vulnerable carotid plaques visualised by positron emission...... tomography (PET). Uptake was correlated to quantitative gene expression of known markers of inflammation and plaque vulnerability. METHODS: Ten patients with recent transient ischaemic attack and carotid artery stenosis (>50%) underwent combined FDG-PET and computed tomography angiography (CTA) the day...

  1. Utility of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in a child with chronic granulomatous disease

    International Nuclear Information System (INIS)

    Garg, Gunjan; DaSilva, Raphaella; Bhalakia, Avni; Milstein, David M.

    2016-01-01

    We report the fluorodeoxyglucose positron emission tomography/computed tomography (FDG - PET/CT) findings in an 11-month-old boy with suspected milk protein allergy, presented to the hospital with 2-month history of fever of unknown origin and failure to thrive. It showed FDG avid lymphadenopathy above and below the diaphragm and splenic focus, which could represent diffuse inflammatory process or lymphoma. Subsequent jejunal biopsy showed non-necrotizing granulomas

  2. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Moyer, B.R.; Mathis, C.A.; Ganz, E.; Huesman, R.H.; Derenzo, S.E.

    1982-01-01

    Positron emission tomography (PET) of the heart can measure blood perfusion, metabolism of fatty acids, metabolism of sugars, uptake of amino acids and can quantitate infarction volume. The principles which are basic to PET instrumentation and procedures for quantitative studies of the heart muscle with examples of measurements of myocardial flow and metabolism, are reviewed

  3. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Huesman, R.H.; Derenzo, S.E.; Moyer, B.R.; Mathis, C.A.; Ganz, E.; Knittel, B.

    1983-01-01

    Positron emission tomography (PET) of the heart can measure blood perfusion, metabolism of fatty acids, metabolism of sugars, uptake of amino acids and can quantitate infarction volume. The principles are reviewed which are basic to PET instrumentation and procedures for quantitative studies of human physiology with examples of measurements of myocardial flow and metabolism

  4. Extensive Tattoos Mimicking Lymphatic Metastasis on Positron Emission Tomography Scan in a Patient With Cervical Cancer.

    Science.gov (United States)

    Grove, Narine; Zheng, Ma; Bristow, Robert E; Eskander, Ramez N

    2015-07-01

    Positron emission tomography (PET) fused with computed tomography (CT) imaging is common in the clinical assessment of patients with locally advanced cervical cancer. Limitations to the utilization and interpretation of PET-CT scans in patients with cervical cancer have been described, including false-positive findings secondary to tattoo ink. A 32-year-old woman presented with clinical stage 1B1 cervical cancer and extensive tattoos of the lower extremities. Preoperative PET-CT scan identified two ileac lymph nodes with increased fluorine-18-deoxyglucose uptake suspicious for metastatic disease. At the time of surgical resection, bilateral pigmented lymph nodes were identified with histologic examination showing deposition of tattoo ink and no malignant cells. Physicians should be cognizant of the possible effects of tattoos on PET-CT findings while counseling patients and formulating a treatment program.

  5. Usefulness of 18F-fluorodeoxyglucose positron emission tomography in follicular lymphoma management

    International Nuclear Information System (INIS)

    Le Dortz, L.; Devillers, A.; Prigent, F.; Bahri, H.; Hervouet, T.; Garin, E.; Guibert, S. de.; Lamy, T.; Rolland, Y.; Bayat, S.

    2009-01-01

    Purpose To assess the usefulness of positron emission tomography/computed tomography in staging, prognosis evaluation and re staging of patients with follicular lymphoma. Patients and methods a retrospective study was performed on 45 patients with untreated biopsy-proven follicular lymphoma who underwent F.D.G.-PET/CT and CT before and after chemo-immunotherapy induction treatment (rituximab combined with cyclophosphamide, doxorubicin, vincristine and prednisone). Results PET/CT detected more nodal (+51%) and extra nodal (+89%) lesions than CT. PET/CT changed Ann Arbor stage in eight patients (18%). Five patients (11%) initially considered with early stage (I/II) were finally managed as advanced stage (III/IV). In this study, initial PET/CT was significantly more accurate to identify patients with poor prognosis than F.L.I.P.I.. Poor prognosis was defined as incomplete therapeutic response or early relapse. Accuracy of PET/CT for therapeutic response assessment was significantly higher than that of CT (0.97 vs 0.64), especially because of its ability to identify inactive residual masses. Beside, post-treatment PET/CT was able to predict patients outcome. The median progression free survival (P.F.S.) was 48 months in the PET/CT negative group as compared to 17.2 months for the group with residual uptake (P < 10-4). Conclusion F.D.G.-PET/CT is a very useful tool for staging, assessing prognosis and therapeutic response of patients with follicular lymphoma. (authors)

  6. Multidetector CT Assessment of Lymph Node Size for Nodal Staging in Patients with Potentially Operable Squamous Esophageal Cancer and the 18F-FDG Positron Emission Tomography CT Correlation

    International Nuclear Information System (INIS)

    Yoom, Soo Kyung; Jung, Jung Im; Ahn, Myeong Im; Park, Jae Gil; Yoo, Ie Ryung; Park, Seog Hee; Park, Mi Jung; Park, Hyun Jin

    2010-01-01

    To investigate the size criteria of multidetector computed tomography (MDCT) for the evaluation metastatic lymph nodes (LNs) for potentially operable squamous esophageal cancer, and to compare this information with the results of positron emission tomography-CT (PET-CT). Twenty-four patients who underwent radical esophagectomy for esophageal cancer were studied. All patients had preoperative MDCT and PET-CT. The MDCT findings were compared with those of PET-CT and were correlated with the surgical records. The receiver operating characteristic (ROC) curve method was used to determine the appropriate cut-off value to distinguish benign from metastatic LNs. The size of metastatic LNs (9.35 ± 3.41 mm) was significantly larger than that of benign LNs (5.74 ± 1.64 mm) (p<0.001). The best cut-off value was 7 mm (81.8% sensitivity, 80.8% specificity). PET-CT detected all metastatic LNs except for four in the peritumoral region. The sensitivity and specificity of metastatic LN evaluation on PET-CT were 82.6% and 99.4%, respectively. Only one LN without metastasis showed increased fluoro-2-deoxy-D-glucose uptake on PET-CT. Size of metastatic LNs can typically be < 10 mm. For MDCT, the short diameter of 7 mm may be the optimal criterion. PET-CT is very accurate for the assessment of metastatic LNs except for those in the peritumoral region

  7. Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) Combined with Positron Emission Tomography-Computed Tomography (PET-CT) and Video-Electroencephalography (VEEG) Have Excellent Diagnostic Value in Preoperative Localization of Epileptic Foci in Children with Epilepsy.

    Science.gov (United States)

    Wang, Gui-Bin; Long, Wei; Li, Xiao-Dong; Xu, Guang-Yin; Lu, Ji-Xiang

    2017-01-01

    BACKGROUND To investigate the effect that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has on surgical decision making relative to video-electroencephalography (VEEG) and positron emission tomography-computed tomography (PET-CT), and if the differences in these variables translates to differences in surgical outcomes. MATERIAL AND METHODS A total of 166 children with epilepsy undergoing preoperative DCE-MRI, VEEG, and PET-CT examinations, surgical resection of epileptic foci, and intraoperative electrocorticography (ECoG) monitoring were enrolled. All children were followed up for 12 months and grouped by Engles prognostic classification for epilepsy. Based on intraoperative ECoG as gold standard, the diagnostic values of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and combined application of DCE-MRI, VEEG, and PET-CT in preoperative localization for epileptic foci were evaluated. RESULTS The sensitivity of DCE-MRI, VEEG, and PET-CT was 59.64%, 76.51%, and 93.98%, respectively; the accuracy of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, and DCE-MRI combined with PET-CT was 57.58%, 67.72%, 91.03%, 91.23%, and 96.49%, respectively. Localization accuracy rate of the combination of DCE-MRI, VEEG, and PET-CT was 98.25% (56/57), which was higher than that of DCE-MRI combined with VEEG and of DCE-MRI combined with PET-CT. No statistical difference was found in the accuracy rate of localization between these three combined techniques. During the 12-month follow-up, children were grouped into Engles grade I (n=106), II (n=31), III (n=21), and IV (n=8) according to postoperative conditions. CONCLUSIONS All DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and DCE-MRI combined with VEEG and PET-CT examinations have excellent accuracy in preoperative localization of epileptic foci and present excellent postoperative efficiency, suggesting that these combined imaging methods are suitable for serving as the

  8. Simultaneous 68Ga DOTATATE Positron Emission Tomography/Magnetic Resonance Imaging in Meningioma Target Contouring: Feasibility and Impact Upon Interobserver Variability Versus Positron Emission Tomography/Computed Tomography and Computed Tomography/Magnetic Resonance Imaging.

    Science.gov (United States)

    Maclean, J; Fersht, N; Sullivan, K; Kayani, I; Bomanji, J; Dickson, J; O'Meara, C; Short, S

    2017-07-01

    The increasing use of highly conformal radiation techniques to treat meningioma confers a greater need for accurate targeting. Several groups have shown that positron emission tomography/computed tomography (PET/CT) information alters meningioma targets contoured by single observers, but whether this translates into improved accuracy has not been defined. As magnetic resonance imaging (MRI) is the cornerstone of meningioma target contouring, simultaneous PET/MRI may be superior to PET/CT. We assessed whether 68 Ga DOTATATE PET imaging (from PET/CT and PET/MRI) reduced interobserver variability (IOV) in meningioma target volume contouring. Ten patients with meningioma underwent simultaneous 68 Ga DOTATATE PET/MRI followed by PET/CT. They were selected as it was anticipated that target volume definition in their cases would be particularly challenging. Three radiation oncologists contoured target volumes according to an agreed protocol: gross tumour volume (GTV) and clinical target volume (CTV) on CT/MRI alone, CT/MRI+PET(CT) and CT/MRI+PET(MRI). GTV/CTV Kouwenhoven conformity levels (KCL), regions of contour variation and qualitative differences between PET(CT) and PET(MRI) were evaluated. There was substantial IOV in contouring. GTV mean KCL: CT/MRI 0.34, CT/MRI+PET(CT) 0.38, CT/MRI+PET(MRI) 0.39 (P = 0.06). CTV mean KCL: CT/MRI 0.31, CT/MRI+PET(CT) 0.35, CT/MRI+PET(MRI) 0.35 (P = 0.04 for all groups; P > 0.05 for individual pairs). One observer consistently contoured largest and one smallest. Observers rarely decreased volumes in relation to PET. Most IOV occurred in bone followed by dural tail, postoperative bed and venous sinuses. Tumour edges were qualitatively clearer on PET(MRI) versus PET(CT), but this did not affect contouring. IOV in contouring challenging meningioma cases was large and only slightly improved with the addition of 68 Ga DOTATATE PET. Simultaneous PET/MRI for meningioma contouring is feasible, but did not improve IOV versus PET/CT

  9. PET/CT in Radiation Therapy Planning

    DEFF Research Database (Denmark)

    Specht, Lena; Berthelsen, Anne Kiil

    2018-01-01

    Radiation therapy (RT) is an important component of the management of lymphoma patients. Most lymphomas are metabolically active and accumulate 18F-fluorodeoxyglucose (FDG). Positron emission tomography with computer tomography (PET/CT) imaging using FDG is used routinely in staging and treatment...

  10. Is positron emission tomography useful in stroke?

    NARCIS (Netherlands)

    DeReuck, J; Leys, D; DeKeyser, J

    Positron emission tomography (PET) has been widely used in the study of stroke and related cerebrovascular diseases. It has shown the various stages leading to cerebral infarction and defined the significance of the ischaemic penumbra. PET scan can predict the clinical outcome of patients with acute

  11. Positron emission tomography in malignant haematological disease

    NARCIS (Netherlands)

    Schot, Bartholomeus Wilhelmus

    2007-01-01

    Positron emission tomography (PET) is a diagnostic technique with a promising role especially in the haemato-oncology. Although its use in the management ; of malignant lymphoma seems to be established already, much about the true potential and drawbacks of FDG-PET in this disease are still unknown.

  12. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  13. Diagnosis and evaluation of gastric cancer by positron emission tomography

    Science.gov (United States)

    Wu, Chen-Xi; Zhu, Zhao-Hui

    2014-01-01

    Gastric cancer is the second leading cause of cancer mortality worldwide. The diagnosis of gastric cancer has been significantly improved with the broad availability of gastrointestinal endoscopy. Effective technologies for accurate staging and quantitative evaluation are still in demand to merit reasonable treatment and better prognosis for the patients presented with advanced disease. Preoperative staging using conventional imaging tools, such as computed tomography (CT) and endoscopic ultrasonography, is inadequate. Positron emission tomography (PET), using 18F-fluorodeoxyglucose (FDG) as a tracer and integrating CT for anatomic localization, holds a promise to detect unsuspected metastasis and has been extensively used in a variety of malignancies. However, the value of FDG PET/CT in diagnosis and evaluation of gastric cancer is still controversial. This article reviews the current literature in diagnosis, staging, response evaluation, and relapse monitoring of gastric cancer, and discusses the current understanding, improvement, and future prospects in this area. PMID:24782610

  14. Comparison of 18F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    International Nuclear Information System (INIS)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk

    2015-01-01

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  15. ¹⁸F-fluorodeoxyglucose-positron emission tomography/computed tomography in malignancies of the thyroid and in head and neck squamous cell carcinoma: a review of the literature.

    Science.gov (United States)

    Lauridsen, Jeppe Kiilerich; Rohde, Max; Thomassen, Anders

    2015-01-01

    18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) is a valuable diagnostic tool in a spectrum of malignant and benign conditions, because of a high sensitivity to detect even very small lesions with increased metabolism. This review focuses on the use of FDG-PET/CT in malignancies of the thyroid gland and in head and neck squamous cell carcinoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. FDG PET and PET/CT : EANM procedure guidelines for tumour PET imaging: version 1.0

    NARCIS (Netherlands)

    Boellaard, Ronald; O'Doherty, Mike J.; Weber, Wolfgang A.; Mottaghy, Felix M.; Lonsdale, Markus N.; Stroobants, Sigrid G.; Oyen, Wim J. G.; Kotzerke, Joerg; Hoekstra, Otto S.; Pruim, Jan; Marsden, Paul K.; Tatsch, Klaus; Hoekstra, Corneline J.; Visser, Eric P.; Arends, Bertjan; Verzijlbergen, Fred J.; Zijlstra, Josee M.; Comans, Emile F. I.; Lammertsma, Adriaan A.; Paans, Anne M.; Willemsen, Antoon T.; Beyer, Thomas; Bockisch, Andreas; Schaefer-Prokop, Cornelia; Delbeke, Dominique; Baum, Richard P.; Chiti, Arturo; Krause, Bernd J.

    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about [18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed

  17. FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0

    NARCIS (Netherlands)

    Boellaard, Ronald; O'Doherty, Mike J.; Weber, Wolfgang A.; Mottaghy, Felix M.; Lonsdale, Markus N.; Stroobants, Sigrid G.; Oyen, Wim J. G.; Kotzerke, Joerg; Hoekstra, Otto S.; Pruim, Jan; Marsden, Paul K.; Tatsch, Klaus; Hoekstra, Corneline J.; Visser, Eric P.; Arends, Bertjan; Verzijlbergen, Fred J.; Zijlstra, Josee M.; Comans, Emile F. I.; Lammertsma, Adriaan A.; Paans, Anne M.; Willemsen, Antoon T.; Beyer, Thomas; Bockisch, Andreas; Schaefer-Prokop, Cornelia; Delbeke, Dominique; Baum, Richard P.; Chiti, Arturo; Krause, Bernd J.

    2010-01-01

    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about[18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed

  18. FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0

    NARCIS (Netherlands)

    Boellaard, R.; O'Doherty, M.J.; Weber, W.A.; Mottaghy, F.M.; Lonsdale, M.N.; Stroobants, S.G.; Oyen, W.J.G.; Kotzerke, J.; Hoekstra, O.S.; Pruim, J.; Marsden, P.K.; Tatsch, K.; Hoekstra, C.J.; Visser, E.P.; Arends, B.; Verzijlbergen, F.J.; Zijlstra, J.M.; Comans, E.F.I.; Lammertsma, A.A.; Paans, A.M.; Willemsen, A.T.; Beyer, T.; Bockisch, A.; Schaefer-Prokop, C.; Delbeke, D.; Baum, R.P.; Chiti, A.; Krause, B.J.

    2010-01-01

    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about [18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed

  19. Dual-modality PET/CT instrumentation-today and tomorrow

    DEFF Research Database (Denmark)

    Lonsdale, Markus Nowak; Beyer, Thomas

    2010-01-01

    Positron emission tomography (PET) has proven to be a clinically valuable imaging modality, particularly for oncology staging and therapy follow-up. The introduction of combined PET/CT imaging has helped address challenging imaging situations when anatomical information on PET-only was inadequate...

  20. Application of positron emission tomography-computed tomography in the diagnosis of pulmonary ground-glass nodules.

    Science.gov (United States)

    Hu, Lili; Pan, Yuanwei; Zhou, Zhigang; Gao, Jianbo

    2017-11-01

    The aim of the present study was to investigate the value of positron emission tomography-computed tomography (PET-CT) using 18 F-fluorodeoxyglucose in the clinical diagnosis of pulmonary ground-glass nodule. In total, 54 patients with pulmonary GGN that were identified by PET-CT examination were selected and confirmed by pathology and clinical diagnosis in hospital between April 2014 and April 2015. The association between PET-CT findings and pathology, and the value of PET-CT were then evaluated. In the 54 patients, solitary pulmonary GGN with a nodule diameter of between 0.6 and 2.0 cm were detected. Amongst them, the PET-CT examination of 42 patients revealed hyper metabolic nodules, and were all mixed GGN type nodules with a diameter >1 cm. The PET-CT examination of the remaining 12 patients demonstrated no evidence of metabolic abnormalities and the nodules in these patients were pure or mixed GGN with a diameter <1 cm (except 2 cases with a diameter ≥1 cm). Furthermore, the diagnoses for all patients were pathologically confirmed by CT-guided needle biopsy or thoracoscopic surgical resection. Amongst them, there were 41 cases of lung adenocarcinoma, 4 cases of fungal infection, 7 cases of inflammation and 2 cases of adenomatoid hyperplasia. Additionally, PET-CT has a lower detection rate for smaller GGN exhibits no clear advantage for pure GGN, but has a higher detection rate for larger GGN. In conclusion, to a certain extent, PET-CT makes up for the shortcomings of traditional imaging and has some clinical value for the diagnosis of GGN.

  1. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  2. The role of Fluorine-18-Fluorodeoxyglucose positron emission tomography in staging and restaging of patients with osteosarcoma

    International Nuclear Information System (INIS)

    Quartuccio, Natale; Treglia, Giorgio; Salsano, Marco; Mattoli, Maria Vittoria; Muoio, Barbara; Piccardo, Arnoldo; Lopci, Egesta; Cistaro, Angelina

    2013-01-01

    The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with Fluorine-18-Fluorodeoxyglucose (FDG) in patients with osteosarcoma (OS). A comprehensive literature search of published studies through October 10 th , 2012 in PubMed/MEDLINE, Embase and Scopus databases regarding whole-body FDG-PET and FDG-PET/CT in patients with OS was performed. We identified 13 studies including 289 patients with OS. With regard to the staging and restaging of OS, the diagnostic performance of FDG-PET and PET/CT seem to be high; FDG-PET and PET/CT seem to be superior to bone scintigraphy and conventional imaging methods in detecting bone metastases; conversely, spiral CT seems to be superior to FDG-PET in detecting pulmonary metastases from OS Metabolic imaging may provide additional information in the evaluation of OS patients. The combination of FDG-PET or FDG-PET/CT with conventional imaging methods seems to be a valuable tool in the staging and restaging of OS and may have a relevant impact on the treatment planning

  3. Fluorodeoxyglucose positron emission tomography/computed tomography findings in a patient with cerebellar mutism after operation in posterior fossa

    Directory of Open Access Journals (Sweden)

    Gonca Kara Gedik

    2017-03-01

    Full Text Available Cerebellar mutism is a transient period of speechlessness that evolves after posterior fossa surgery in children. Although direct cerebellar and brain stem injury and supratentorial dysfunction have been implicated in the mediation of mutism, the pathophysiological mechanisms involved in the evolution of this kind of mutism remain unclear. Magnetic resonance imaging revealed dentatothalamocortical tract injuries and single photon emission computed tomography showed cerebellar and cerebral hypoperfusion in patients with cerebellar mutism. However, findings with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT in this group of patients have not been documented previously. In this clinical case, we report a patient who experienced cerebellar mutism after undergoing a posterior fossa surgery. Right cerebellar and left frontal lobe hypometabolism was shown using FDG PET/CT. The FDG metabolism of both the cerebellum and the frontal lobe returned to normal levels after the resolution of the mutism symptoms.

  4. Image registration/fusion software for PET and CT/MRI by using simultaneous emission and transmission scans

    International Nuclear Information System (INIS)

    Kitamura, Keishi; Amano, Masaharu; Sato, Tomohiko; Okumura, Takeshi; Konishi, Norihiro; Komatsu, Masahiko

    2003-01-01

    When PET (positron emission tomography) is used for oncology studies, it is important to register and over-lay PET images with the images of other anatomical modalities, such as those obtained by CT (computed tomography) or MRI (magnetic resonance imaging), in order for the lesions to be anatomically located with high accuracy. The Shimadzu SET-2000W Series PET scanners provide simultaneous acquisition of emission and transmission data, which is capable of complete spatial alignment of both functional and attenuation images. This report describes our newly developed image registration/fusion software, which reformats PET emission images to the CT/MRI grid by using the transform matrix obtained by matching PET transmission images with CT/MRI images. Transmission images are registered and fused either automatically or manually, through 3-dimensional rotation and translation, with the transaxial, sagittal, and coronal fused images being monitored on the screen. This new method permits sufficiently accurate registration and efficient data processing with promoting effective use of CT/MRI images of the DICOM format, without using markers in data acquisition or any special equipment, such as a combined PET/CT scanner. (author)

  5. F-18 Sodium Fluoride Positron Emission Tomography/Computed Tomography for Detection of Thyroid Cancer Bone Metastasis Compared with Bone Scintigraphy.

    Science.gov (United States)

    Lee, Hyunjong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun

    2016-01-01

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  6. Fluorodeoxyglucose positron emission tomography in pancreatic cancer: an unsolved problem

    International Nuclear Information System (INIS)

    Kato, Takashi; Fukatsu, Hiroshi; Ito, Kengo; Tadokoro, Masanori; Ota, Toyohiro; Ikeda, Mitsuru; Isomura, Takayuki; Ito, Shigeki; Nishino, Masanari; Ishigaki, Takeo

    1995-01-01

    The aim of this study was to examine the significance and problems of 2-[fluorine-18]-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in diagnosing pancreatic cancer and mass-forming pancreatitis (MFP). PET, X-ray computed tomography (CT) and magnetic resonance (MR) imaging were performed in 15 patients with pancreatic cancer and nine patients with MFP. The areas of the PET scan were determined according to the markers drawn on the patients at CT or MR imaging. Regions of interests (ROIs) were placed by reference to the CT or MR images corresponding to the PET images. Tissue metabolism was evaluated by the differential absorption ratio (DAR) at 50 min after intravenous injection of FDG [DAR = tissue tracer concentration/(injected dose/body weight). The DAR value differed significantly in pancreatic cancer (mean±SD, 4.64±1.94) and MFP (mean±SD, 2.84±2.22) (P<0.05). In one false-negative case (mucinous adenocarcinoma), the tumour contained a small number of malignant cells. In one false-positive case, lymphocytes accumulated densely in the mass in the pancreatic head. Further studies are necessary to investigate the histopathological characteristics (especially the cellularity) and other factors affecting the FDG DAR on PET images. (orig.)

  7. Prognostic impact of clinician-based interpretation of 18F-fluorodeoxyglucose positron emission tomography/computed tomography reports obtained in patients with newly diagnosed diffuse large B-cell lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen J; El-Galaly, Tarec C; Hutchings, Martin

    2014-01-01

    The aim of this study was to evaluate the prognostic value of clinician interpretation of positron emission tomography/computed tomography (PET/CT) reports at mid-therapy, interim PET (I-PET) and after the end of first-line therapy (E-PET) in patients with diffuse large B-cell lymphoma (DLBCL.......001) for positive, indeterminate and negative interpretation of PET/CT reports. Progression-free survival and OS did not differ significantly in patients with a negative and an indeterminate I-PET report. The use of well-defined reporting criteria, e.g. the Deauville five-point scale, is likely to reduce the number...

  8. FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0

    DEFF Research Database (Denmark)

    Boellaard, Ronald; O'Doherty, Mike J; Weber, Wolfgang A

    2010-01-01

    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about[18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed tomogr...

  9. Evaluation of esophageal cancer by positron emission tomography

    International Nuclear Information System (INIS)

    Himeno, Shinji; Yasuda, Seiei; Shimada, Hideo; Tajima, Tomoo; Makuuchi, Hiroyasu

    2002-01-01

    A retrospective study was performed to determine the indications for positron emission tomography (PET) using [ 18 F]fluorodeoxyglucose (FDG) in patients with esophageal cancer, including those with early cancer, and to investigate whether the tumor-to-normal ratio (T/N ratio) could be used as a substitute for the standardized uptake value (SUV). Thirty-six patients were included in the study. Thirty-one patients who had 36 biopsy-proven lesions (35 squamous cell carcinomas and one small cell carcinoma) underwent PET study prior to treatment. PET images were evaluated visually and the relationship between the depth of invasion and the PET findings were examined in 22 lesions of 19 patients from whom specimens were obtained from the primary tumor by surgery or endoscopic mucosal resection. PET results were also compared with computed tomography (CT) and endoscopic ultrasonography (EUS) for detection of regional lymph node metastases in 18 patients who underwent extended lymph node dissection. Five patients underwent PET studies for the detection of recurrence and the PET findings were compared with their CT findings. The T/N ratio and the SUV were calculated for 20 primary tumors. Among the 15 tumors that were pT1b or greater, all 15 were positive on PET and all seven of the lesions confined to the mucosa (Tis or T1a) were negative. The sensitivity, specificity and accuracy of detecting nodal involvement were, respectively, 37.5, 96.1 and 88.3% by CT, 30.8, 88.5 and 81.0% by EUS and 41.7, 100 and 92.2% by PET. More sites of recurrence were detected by PET than by CT. There was no statistically significant correlation between the SUV and the T/N ratio. PET imaging can detect primary esophageal cancer with a depth of invasion of T1b or greater, but Tis and T1a tumors are undetectable. PET seems to be more accurate than CT or EUS for diagnosing lymph node metastasis. The T/N ratio cannot be used as a substitute for the SUV. (author)

  10. Comparison of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk [Konyang University Myunggok Medical Research Institute, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2015-01-15

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  11. [Positron emission tomography combined with computed tomography in the initial evaluation and response assessment in primary central nervous system lymphoma].

    Science.gov (United States)

    Mercadal, Santiago; Cortés-Romera, Montserrat; Vélez, Patricia; Climent, Fina; Gámez, Cristina; González-Barca, Eva

    2015-06-08

    To evaluate the role of positron emission tomography combined with computed tomography (PET-CT) in the initial evaluation and response assessment in primary central nervous system lymphoma (PCNSL). Fourteen patients (8 males) with a median age 59.5 years diagnosed of PCNSL. A brain PET-CT and magnetic resonance imaging (MRI) were performed in the initial evaluation. In 7 patients a PET-CT after treatment was performed. PET-CT showed at diagnosis 31 hypermetabolic focuses and MRI showed 47 lesions, with a good grade of concordance between both (k = 0.61; P = .005). In the response assessment, correlation between both techniques was good, and PET-CT was helpful in the appreciation of residual MRI lesions. Overall survival at 2 years of negative vs. positive PET-CT at the end of treatment was 100 vs. 37.5%, respectively (P = .045). PET-CT can be useful in the initial evaluation of PCNSL, and especially in the assessment of response. Despite the fact that PET-CT detects less small lesions than MRI, a good correlation between MRI and PET-CT was observed. It is effective in the evaluation of residual lesions. Prospective studies are needed to confirm their possible prognostic value. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  12. A Case of Low-Grade Primary Cardiac Lymphoma with Pericardial Effusion Diagnosed by Combined 18F-Fluorodeoxyglucose Positron Emission Tomography and Computed Tomography (FDG-PET/CT) Imaging and Effusion Cytology.

    Science.gov (United States)

    Fukunaga, Hisanori; Tatewaki, Yasuko; Mutoh, Tatsushi; Shimomura, Hideo; Yamamoto, Shuzo; Terao, Chiaki; Totsune, Tomoko; Nakagawa, Manabu; Taki, Yasuyuki

    2018-03-14

    BACKGROUND Primary cardiac lymphoma is rare and can be an aggressive disease, depending on the grade. A case is reported of low-grade primary cardiac lymphoma associated with a pericardial effusion. 18F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG-PET/CT) imaging was useful in the diagnosis and in evaluating the disease activity in this case. CASE REPORT A 72-year-old Japanese woman visited a general practitioner, complaining of dyspnea associated with cardiac tamponade. Pericardiocentesis was performed, and Group V malignant cells were identified by cytology, suspicious for malignant lymphoma. Whole-body FDG-PET/CT scans showed no pleural effusion or lymph node metastasis supporting the diagnosis of primary cardiac lymphoma diagnosed on pericardial effusion. The laboratory investigations showed that levels of serum soluble interleukin-2 (IL-2) receptor (sIL-2R), a diagnostic and prognostic marker for malignant lymphoma, were not elevated (258 U/ml). A six-month follow-up FDG-PET/CT scan showed an increased volume of the pericardial effusion and mild but abnormal uptake diffusely in the pericardial space, and the sIL-2R was slightly elevated (860 U/ml). No abnormal FDG accumulation outside the retained pericardial effusion was noted, which was compatible with a clinical picture of low-grade primary cardiac lymphoma, and in a period of watchful waiting during the first two years later, the sIL-2R had reduced to 195 U/ml. CONCLUSIONS This is a rare case of low-grade primary cardiac lymphoma detected in a pericardial effusion, and highlights the utility of the FDG-PET/CT scan as a valuable diagnostic and follow-up modality.

  13. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by 18F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience

    International Nuclear Information System (INIS)

    Masala, Salvatore; Bartolucci, Alberto D.; Mammucari, Matteo; Simonetti, Giovanni; Schillaci, Orazio; Calabria, Ferdinando

    2011-01-01

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. 18 F-FDG positron emission tomography/computed tomography ( 18 F-FDG PET/CT) is a single technique of imaging that provides in a ''single step'' both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV max ) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV max value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation. (orig.)

  14. The limitation and coordination of CT and positron emission tomography in the diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Zhang Jin'e; Liang Changhong; Zhao Zhenjun; Wang Shuxia; Qiao Suixian; He Hui; Zhang Jia; Ru Guangteng

    2005-01-01

    Objective: To Analyze the limitation and coordination of CT and positron emission tomography (PET) in the diagnosis of pulmonary nodules. Methods: A retrospective study was undertaken in 118 patients with pulmonary nodules which had CT and PET scan. The interval between examinations of various imaging equipment was less than 2 weeks. The diameter of nodules ranged from 2 cm to 4 cm with an average of 2.7 cm. The nodules were proved as lung cancer by pathology in 85 cases and metastatic tumor in 2 cases, benign nodules in 31 cases, including 8 cases of tuberculosis, 6 cases of hamartoma, 6 cases of inflammatory pseudotumor, 4 cases of chronic nonspecific inflammation, 3 cases of inflammation granuloma, 2 cases of mycosis, 1 case of abscess, and 1 case of globular atelectasis. Results: 93 cases were correctly diagnosed and 25 cases were misdiagnosed with CT in 118 cases of pulmonary nodules. The misdiagnosis rate of CT was 21.2%. 12 cases of lung cancer were misdiagnosed as benign and 13 cases of benign nodules were misdiagnosed as lung cancer. 96 cases were correctly diagnosed and 22 cases were misdiagnosed with PET. The misdiagnosis rate of PET was 18.6%. 10 cases of malignant nodules were misdiagnosed as benign and 12 cases of benign nodules were misdiagnosed as lung cancer. 108 cases were correctly diagnosed and 10 cases were misdiagnosed with CT coordinated with PET. The misdiagnosis rate was 8.5%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT, PET, and CT coordinated with PET were 86.2%, 58.1%, 85.2%, 60.0%, 78.8% and 88.5%, 61.3%, 86.5%, 65.5%, 81.4%, and 97.7%, 74.2%, 91.4%, 92.0%, 91.5% respectively. The accuracy showed no significant difference between CT and PET (χ 2 =0.625, P=0.239), but there were significant difference between CT coordinated with PET and CT or PET (χ 2 =7.762 and 5.318, P=0.005 and 0021). Conclusion: The features of CT and PET in benign and malignant pulmonary nodules are partly

  15. 18F-fluorodeoxyglucose positron emission tomography in uterine carcinosarcoma

    International Nuclear Information System (INIS)

    Ho, Kung-Chu; Yen, Tzu-Chen; Lai, Chyong-Huey; Wu, Tzu-I; Chang, Ting-Chang; Huang, Huei-Jean; Ng, Koon-Kwan; Lin, Gigin; Wang, Chun-Chieh; Hsueh, Swei

    2008-01-01

    Uterine carcinosarcomas clinically confined to the uterus usually harbor occult metastases. We conducted a pilot study to evaluate the value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in uterine carcinosarcoma. Patients with histologically confirmed uterine carcinosarcoma were enrolled. Abdominal and pelvic magnetic resonance imaging (MRI)/whole-body computed tomography (CT) scan, and whole-body 18 F-FDG PET or PET/CT were undertaken for primary staging, evaluating response, and restaging/post-therapy surveillance. The clinical impact of 18 F-FDG PET was determined on a scan basis. A total of 19 patients were recruited and 31 18 F-FDG PET scans (including 8 scans performed on a PET/CT scanner) were performed. Positive impacts of scans were found in 36.8% (7/19) for primary staging, 66.7% (2/3) for monitoring response, and 11.1% (1/9) for restaging/post-therapy surveillance. PET excluded falsely inoperable disease defined by MRI in two patients. Aggressive treatment applying to three patients with PET-defined resectable stage IVB disease seemed futile. Two patients died of disease shortly after salvage therapy restaged by PET. With PET monitoring, one stage IVB patient treated by targeted therapy only was alive with good performance. Using PET did not lead to improvement of overall survival of this series compared with the historical control (n = 35) (P 0.779). The preliminary results suggest that 18 F-FDG PET is beneficial in excluding falsely inoperable disease for curative therapy and in making a decision on palliation for better quality of life instead of aggressive treatment under the guidance of PET. PET seems to have limited value in post-therapy surveillance or restaging after failure. (orig.)

  16. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  17. Clinical applications of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in carcinoma of unknown primary

    Institute of Scientific and Technical Information of China (English)

    HU Man; YU Jin-ming; ZHAO Wei; ZHANG Pin-liang; JU Gui-fang; FU Zheng; ZHANG Guo-li; KONG Li; YANG Yan-qin; MA Yi-dong

    2011-01-01

    Background Carcinoma of unknown primary (CUP) encompasses a heterogeneous group of tumors with varying clinical features. The management of patients of CUP remains a clinical challenge. The purpose of this study was to evaluate the clinical applications of integrated 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) information in patients with CUP,including detecting the occult primary tumor and effecting on disease therapy.Methods One hundred and forty-nine patients with histologically-proven metastases of CUP were included. For all patients,the conventional diagnostic work-up was unsuccessful in localizing the primary site. Whole-body PET/CT images were obtained approximately 60 minutes after intravenous injection of 350-425 MBq of 18F-FDG.Results In 24.8% of patients,FDG PET/CT detected primary tumors that were not apparent after conventional workup.In this group of patients,the overall sensitivity,specificity,and accuracy rates of FDG PET/CT in detecting unknown primary tumors were 86.0%,87.7%,and 87.2%,respectively. FDG PET/CT imaging also led to the detection of previously unrecognized metastases in 29.5% of patients. Forty-seven (31.5%,47 of 149) patients underwent a change in therapeutic management.Conclusions FDG PET/CT is a valuable tool in patients with CUP,because it assisted in detecting unknown primary tumors and previously unrecognized distant metastases,and optimized the mangement of these patients.

  18. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  19. Positron emission tomography/computed tomography (PET/CT) in children.

    Science.gov (United States)

    Shore, Richard M

    2008-06-01

    Although PET imaging has been available for more than two decades, its use has greatly increased lately due to the advent of PET/CT, readily available sources of commercially supplied FDG, and mobile scanners. These features have enabled PET scanning to expand beyond select major university medical centers, with on-site cyclotron facilities to smaller institutions including free- standing children's hospitals. In these settings, imaging is generally limited to FDG, which suffices for most applications, with the majority of studies performed for tumor imaging. FDGI is being used for evaluation of many tumors in children, with its use in lymphoma being the most established. In lymphoma, it has proven quite useful in determining whether active tumor is present in residual masses following treatment, which may otherwise contain only residual fibrous tissue. For brain tumors, FDGI has some relation to tumor grade, although its more important role is distinguishing recurrent or residual tumor from the effects of treatment, particularly radiation necrosis. For neurological evaluation, interictal FDGI is helpful in localizing potential seizure foci for subsequent subdural EEG monitoring. Because of the relatively long uptake time of FDG, true ictal studies cannot be performed with FDG, and these remain within the domain of SPECT imaging of tracers such as Tc-99m HMPAO. Examinations utilizing radiopharmaceuticals other than FDG are significantly more limited in their availability and are limited to PET centers with on-site cyclotrons. However, these additional agents open the door to many additional studies, including more specific tumor-imaging agents of certain tumors such as neuroblastoma. Another neurotransmitter, F-18-fluoro-L-dopa, is of benefit outside of the central nervous system for evaluating infantile hyperinsulism. The use of PET/CT in children is increasing quickly, particularly FDGI imaging of tumors. It is expected that over the next few years, its role will

  20. Positron emission tomography in epilepsy

    International Nuclear Information System (INIS)

    Hosokawa, Shinichi; Kato, Motohiro; Otsuka, Makoto; Kuwabara, Yasuo; Ichiya, Yuichi; Goto, Ikuo

    1989-01-01

    Positron emission tomography (PET) was performed with the 18 F-fluoro-deoxy-glucose method on 29 patients with epilepsy (generalized epilepsy, 4; partial epilepsy, 24; undetermined type, 1). The subjects were restricted to patients with epilepsy without focal abnormality on X-CT. All the patients with generalized epilepsy showed a normal pattern on PET. Fourteen out of the 24 patients with partial epilepsy and the 1 with epilepsy of undermined type showed focal hypometabolism on PET. The hypometabolic zone was localized in areas including the temporal cortex in 11 patients, frontal in 2 and thalamus in 1. The location of hypometabolic zone and that of interictal paroxysmal activity on EEG were well correlated in most patients. The patients with poorly-controlled seizure showed a higher incidence of PET abnormality (12 out of 13) than those with well-controlled seizures (2 out of 11). The incidence of abnormality on PET and MRI and the location of both abnormality were not necessarily coincident. These results indicated that the PET examination in epilepsy provides valuable information about the location of epileptic focus, and that the findings on PET in patients with partial epilepsy may be one of the good indicators about the intractability of partial epilepsy, and that PET and MRI provide complementary information in the diagnosis of epilepsy. (author)

  1. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    D’Souza, Maria Mathew; D’Souza, Paschal; Sharma, Rajnish; Jaimini, Abhinav; Mondal, Anupam

    2015-01-01

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  2. {sup 11}C-Methionine positron emission tomography may monitor the activity of encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Kenji; Shiga, Tohru; Manabe, Osamu; Tamaki, Nagara [Department of Nuclear Medicine, Graduate School of Medicine, Hokkaido University, Sapporo (Japan)], E-mail: khirata@med.hokudai.ac.jp; Fujima, Noriyuki [Department of Radiology, Graduate School of Medicine, Hokkaido University, Sapporo (Japan); Usui, Reiko [Department of Nuclear Medicine, Graduate School of Medicine, Hokkaido University, Sapporo (Japan); Department of Psychiatry, Graduate School of Medicine, Hokkaido University, Sapporo (Japan); Kuge, Yuji [Central Institute of Isotope Science, Hokkaido University, Sapporo (Japan)

    2012-12-15

    Encephalitis is generally diagnosed by clinical symptoms, cerebrospinal fluid examination, and imaging studies including CT, magnetic resonance imaging (MRI), and perfusion single photon emission tomography (SPECT). However, the role of positron emission tomography (PET) in diagnosis of encephalitis remains unclear. A 49-year-old woman presenting with coma and elevated inflammatory reaction was diagnosed as having encephalitis according to slow activity on electroencephalogram, broad cortical lesion in MR fluid attenuated inversion recovery image, and increased blood flow demonstrated by SPECT. PET revealed increased accumulation of {sup 11}C-methionine (MET) in the affected brain tissues. After the symptom had improved 2 months later, the accumulation of MET as well as the abnormal findings of MR imaging and SPECT was normalized. This case indicated that MET PET may monitor the activity of encephalitis.

  3. Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning.

    Science.gov (United States)

    Scripes, Paola G; Yaparpalvi, Ravindra

    2012-09-01

    The usage of functional data in radiation therapy (RT) treatment planning (RTP) process is currently the focus of significant technical, scientific, and clinical development. Positron emission tomography (PET) using ((18)F) fluorodeoxyglucose is being increasingly used in RT planning in recent years. Fluorodeoxyglucose is the most commonly used radiotracer for diagnosis, staging, recurrent disease detection, and monitoring of tumor response to therapy (Lung Cancer 2012;76:344-349; Lung Cancer 2009;64:301-307; J Nucl Med 2008;49:532-540; J Nucl Med 2007;48:58S-67S). All the efforts to improve both PET and computed tomography (CT) image quality and, consequently, lesion detectability have a common objective to increase the accuracy in functional imaging and thus of coregistration into RT planning systems. In radiotherapy, improvement in target localization permits reduction of tumor margins, consequently reducing volume of normal tissue irradiated. Furthermore, smaller treated target volumes create the possibility of dose escalation, leading to increased chances of tumor cure and control. This article focuses on the technical aspects of PET/CT image acquisition, fusion, usage, and impact on the physics of RTP. The authors review the basic elements of RTP, modern radiation delivery, and the technical parameters of coregistration of PET/CT into RT computerized planning systems. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Role of Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Diagnostic Evaluation of Carcinoma Urinary Bladder: Comparison with Computed Tomography

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Kashyap, Raghava; Mete, Utham Kumar; Narang, Vikram; Das, Ashim; Bhattacharya, Anish; Khandelwal, Niranjan; Mandal, Arup K.

    2014-01-01

    Bladder carcinoma is the most frequent tumor of the urinary tract and accounts 7% of all malignancies in men and 2% of all malignancies in women. This retrospective study was carried out to assess the diagnostic utility of F18-fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the imaging evaluation of bladder carcinoma. Seventy-seven consecutive patients diagnosed to have carcinoma urinary bladder referred for F18-FDG PET/CT were included in this study. Thirty-four patients were for initial staging after transurethral biopsy and remaining 43 patients were for restaging. All patients also underwent CT scan of the abdomen and pelvis. PET/CT findings were correlated with diagnostic CT scan and histopathological findings. In 30 of the 34 patients for initial staging, both PET/CT and CT confirmed the primary lesion in the bladder. Histopathology report was available in 23 patients. Lymph nodes FDG uptake reported to be metastatic in 10/23 patients while CT detected lymph node metastasis in 12 patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy have been calculated to be 87.5%, 80%, 70%, 92%, 82% for PET/CT and 66%, 57%, 50%, 72%, 60% for CT respectively. PET/CT detected metastatic disease in 8 patients whereas CT detected in 4 patients. Of the 43 patients for restaging, local recurrence was detected in 24 patients on both PET/CT and CT. Histopathology report was available in 17 patients. Sensitivity, specificity, PPV, NPV and accuracy were 85%, 60%, 60%, 85%, 70% for PET/CT and 80%, 50%, 40%, 85%, 58% for CT respectively. Nineteen patients were detected to have metastatic disease by PET/CT, whereas CT detected metastases in 11 patients. F-18 FDG PET/CT is a very useful modality in pre-operative staging and monitoring after surgery, chemotherapy or radiotherapy of patients with carcinoma urinary bladder

  5. Positron emission tomography in the evaluation of subdural hematomas

    International Nuclear Information System (INIS)

    Ericson, K.; Bergstroem, M.; Eriksson, L.

    1980-01-01

    Fifteen patients with 21 subdural effusions were investigated both with transmission computer assisted tomography (CAT) and positron emission tomography (PET). The tracer in the emission studies was 68 Ga-EDTA. Twelve lesions were visualized both with CAT and PET. Five lesions that were negative or doubtful on CAT were visualized with PET, whereas four lesions negative or doubtful on PET were demonstrated by CAT. The two methods complement each other due to the fact that they are based on different mechanisms: CAT mainly on attenuation of the fluid collection. PET on isotope accumulation, particularly in the hematoma membranes

  6. Usefulness of CA125 and their kinetic parameters and positron emission tomography/computed tomography (PET/CT) with fluorodeoxyglucose ([18F] FDG) in the detection of recurrent ovarian cancer levels.

    Science.gov (United States)

    Palomar Muñoz, Azahara; Cordero García, José Manuel; Talavera Rubio, Prado; García Vicente, Ana M; González García, Beatriz; Bellón Guardia, María Emiliana; Soriano Castrejón, Ángel; Aranda Aguilar, Enrique

    2017-12-21

    To assess the usefulness of cancer antigen 125 (CA125) serum levels and kinetic values, velocity (CA125vel) and doubling time (CA125dt), as well as fluorodeoxyglucose ([ 18 F]FDG) positron emission tomography/computed tomography (PET/CT), in the detection of ovarian cancer recurrence. To assess the optimal cut-off for CA125, CA125vel and CA125dt to detect relapse with [ 18 F]FDG-PET/CT. A retrospective analysis was performed of 59 [ 18 F]FDG-PET/CT (48 patients) for suspected recurrence of ovarian cancer. Receiver operating characteristic (ROC) curves were plotted and area-under-the curve (AUC) statistics were computed for CA125, CA125vel and CA125dt. The results obtained in the group with normal and high (>35U/ml) CA125 levels were compared. Forty-four cases of recurrence were diagnosed (7 had CA125 ≤35U/ml), whereas 15 showed no disease. All of them were correctly catalogued by PET/CT. In ROC analysis, the discriminatory power of CA125 was relatively high (AUC 0.835) and the optimal cut-off point to reflect active disease was 23.9U/ml. The ROC analyses for the CA125vel and CA125dt showed an AUC of 0.849 and 0.728, respectively, with an optimal cut-off point of 1.96U/ml/month and 0.76 months, respectively. In patients with normal CA125 and recurrence of ovarian cancer, the CA125vel was significantly higher than in patients without recurrence (p=0.029). [ 18 F]FDG-PET/CT is more accurate than CA125 parameters in the detection of ovarian cancer recurrence. CA125 serum levels are essential; nevertheless, CA125 kinetic values must be considered to detect relapse. Particularly in patients with CA125 within normal values, in which a higher CA125vel is indicative of recurrence. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  7. Update on nodal staging in non-small cell lung cancer with integrated positron emission tomography/computed tomography: a meta-analysis.

    Science.gov (United States)

    Pak, Kyoungjune; Park, Sohyun; Cheon, Gi Jeong; Kang, Keon Wook; Kim, In-Joo; Lee, Dong Soo; Kim, E Edmund; Chung, June-Key

    2015-06-01

    Nowadays, the number of primary studies on fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has been increasing rapidly. Thus, we updated meta-analysis to evaluate the test performance of FDG PET/CT for nodal staging in non-small cell lung cancer (NSCLC) including the most recent studies. We performed a systematic search of MEDLINE and EMBASE for English publications using keywords "positron emission tomography", "lung cancer", and "lymph node". All searches were limited to human studies. Inclusion criteria were studies of the initial nodal staging of NSCLC with PET/CT. The reasons for exclusion are as follows: (1) studies with PET, (2) previous therapy before PET/CT, (3) nodal staging not confirmed by histology, and (4) reviews, abstracts, and editorial materials. 786 articles were identified through database searching. 28 studies including 3,255 patients and 11,887 lymph nodes (LN) were eligible for this study. The pooled sensitivity was 0.62 (95% CI 0.54-0.70), widely ranging from 0.13 to 0.98. The specificity ranged between 0.72 and 0.98 with an overall estimated specificity of 0.92 (0.88-0.95) for node-based data. The pooled sensitivity, specificity, positive and negative likelihood ratio were 0.67 (0.54-0.79), 0.87 (0.82-0.91), 5.20 (3.59-7.54), and 0.37 (0.25-0.55) for patient-based data. Studies from tuberculosis (Tb) endemic countries showed lower sensitivity (0.56 vs 0.68, p = 0.03) for node-based data and lower specificity (0.83 vs 0.89, p < 0.01) for patient-based ones. PET/CT has a high specificity, but low sensitivity for detecting LN metastasis in patients with NSCLC. Tb might be one of the main reasons for lower sensitivity of PET/CT in several countries. The primary clinicians of lung cancer should be aware of the possibility of hidden metastatic LNs in bilateral FDG uptake of mediastinal and hilar LNs, especially in the Tb endemic countries.

  8. IgG4-associated multifocal systemic fibrosis detected by cancer screening with 18F-FDG positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Soga, Shigeyoshi; Kita, Tamotsu; Hiratsuka, Miyuki; Sakaguchi, Chiharu; Shinmoto, Hiroshi; Kosuda, Shigeru; Sakata, Ikuko; Miura, Soichiro

    2010-01-01

    Serial fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) studies were performed with an interval of one year in a 62-year-old man with IgG4-associated multifocal systemic fibrosis (IMSF). He first underwent 18 F-FDG PET/CT cancer screening, which revealed multiple 18 F-FDG-avid uptakes in the pancreas, prostate, and lymph nodes in the upper mediastinum, pulmonary hila, porta hepatis, and the left iliac and inguinal regions. He was not symptomatic at this initial examination. The follow-up 18 F-FDG PET/CT study showed disappearance of 18 F-FDG-avid uptake foci in the pancreas despite no treatment having been administered, but demonstrated new lesions in the abdominal para-aortic region and more intense FDG uptake in the porta hepatis lesion. Serial 18 F-FDG PET/CT studies might be useful in monitoring patients with IMSF, as well as evaluating the state of systemic involvement. Findings of 18 F-FDG PET/CT may provide information useful for determining the optimal initiation of IMSF treatment. (author)

  9. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  10. Positron emission tomography in brain function study

    International Nuclear Information System (INIS)

    Wu Hua

    2006-01-01

    Little has been recognized about the advanced brain function. Recent years several new techniques such as event-related potentials, megnetoencephalography, functional magnetic resonance imaging and positron emission tomography (PET) have been used in the study of brain function. The methodology, application study in normal people and clinical patients of PET in brain function are reviewed. (authors)

  11. Omental deposits surveillance in gynecological malignancies at first setting follow up: 18F-FDG PET/CT compared to CT

    OpenAIRE

    Tamer W. Kassem

    2017-01-01

    Objective: The aim of this study was to compare the diagnostic performance of positron emission tomography/computed tomography (PET/CT) scan and CT scan in follow up of proven gynecological malignancies omental deposits in first setting follow up after treatment. Patients and methods: 60 female patients having proven omental deposits from gynecological malignancies underwent PET/CT examination following a preset protocol as baseline study. 34 cases of them had a second PET/CT examination f...

  12. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography-Based Radiotherapy Target Volume Definition in Non-Small-Cell Lung Cancer: Delineation by Radiation Oncologists vs. Joint Outlining With a PET Radiologist?

    International Nuclear Information System (INIS)

    Hanna, Gerard G.; Carson, Kathryn J.; Lynch, Tom; McAleese, Jonathan; Cosgrove, Vivian P.; Eakin, Ruth L.; Stewart, David P.; Zatari, Ashraf; O'Sullivan, Joe M.; Hounsell, Alan R.

    2010-01-01

    Purpose: 18 F-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) has benefits in target volume (TV) definition in radiotherapy treatment planning (RTP) for non-small-cell lung cancer (NSCLC); however, an optimal protocol for TV delineation has not been determined. We investigate volumetric and positional variation in gross tumor volume (GTV) delineation using a planning PET/CT among three radiation oncologists and a PET radiologist. Methods and Materials: RTP PET/CT scans were performed on 28 NSCLC patients (Stage IA-IIIB) of which 14 patients received prior induction chemotherapy. Three radiation oncologists and one PET radiologist working with a fourth radiation oncologist independently delineated the GTV on CT alone (GTV CT ) and on fused PET/CT images (GTV PETCT ). The mean percentage volume change (PVC) between GTV CT and GTV PETCT for the radiation oncologists and the PVC between GTV CT and GTV PETCT for the PET radiologist were compared using the Wilcoxon signed-rank test. Concordance index (CI) was used to assess both positional and volume change between GTV CT and GTV PETCT in a single measurement. Results: For all patients, a significant difference in PVC from GTV CT to GTV PETCT exists between the radiation oncologist (median, 5.9%), and the PET radiologist (median, -0.4%, p = 0.001). However, no significant difference in median concordance index (comparing GTV CT and GTV FUSED for individual cases) was observed (PET radiologist = 0.73; radiation oncologists = 0.66; p = 0.088). Conclusions: Percentage volume changes from GTV CT to GTV PETCT were lower for the PET radiologist than for the radiation oncologists, suggesting a lower impact of PET/CT in TV delineation for the PET radiologist than for the oncologists. Guidelines are needed to standardize the use of PET/CT for TV delineation in RTP.

  13. 18F-fluorodeoxyglucose positron emission tomography/computed tomography-based radiotherapy target volume definition in non-small-cell lung cancer: delineation by radiation oncologists vs. joint outlining with a PET radiologist?

    Science.gov (United States)

    Hanna, Gerard G; Carson, Kathryn J; Lynch, Tom; McAleese, Jonathan; Cosgrove, Vivian P; Eakin, Ruth L; Stewart, David P; Zatari, Ashraf; O'Sullivan, Joe M; Hounsell, Alan R

    2010-11-15

    (18)F-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) has benefits in target volume (TV) definition in radiotherapy treatment planning (RTP) for non-small-cell lung cancer (NSCLC); however, an optimal protocol for TV delineation has not been determined. We investigate volumetric and positional variation in gross tumor volume (GTV) delineation using a planning PET/CT among three radiation oncologists and a PET radiologist. RTP PET/CT scans were performed on 28 NSCLC patients (Stage IA-IIIB) of which 14 patients received prior induction chemotherapy. Three radiation oncologists and one PET radiologist working with a fourth radiation oncologist independently delineated the GTV on CT alone (GTV(CT)) and on fused PET/CT images (GTV(PETCT)). The mean percentage volume change (PVC) between GTV(CT) and GTV(PETCT) for the radiation oncologists and the PVC between GTV(CT) and GTV(PETCT) for the PET radiologist were compared using the Wilcoxon signed-rank test. Concordance index (CI) was used to assess both positional and volume change between GTV(CT) and GTV(PETCT) in a single measurement. For all patients, a significant difference in PVC from GTV(CT) to GTV(PETCT) exists between the radiation oncologist (median, 5.9%), and the PET radiologist (median, -0.4%, p = 0.001). However, no significant difference in median concordance index (comparing GTV(CT) and GTV(FUSED) for individual cases) was observed (PET radiologist = 0.73; radiation oncologists = 0.66; p = 0.088). Percentage volume changes from GTV(CT) to GTV(PETCT) were lower for the PET radiologist than for the radiation oncologists, suggesting a lower impact of PET/CT in TV delineation for the PET radiologist than for the oncologists. Guidelines are needed to standardize the use of PET/CT for TV delineation in RTP. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. Positron Emission Tomography: Principles, Technology, and Recent Developments

    Science.gov (United States)

    Ziegler, Sibylle I.

    2005-04-01

    Positron emission tomography (PET) is a nuclear medical imaging technique for quantitative measurement of physiologic parameters in vivo (an overview of principles and applications can be found in [P.E. Valk, et al., eds. Positron Emission Tomography. Basic Science and Clinical Practice. 2003, Springer: Heidelberg]), based on the detection of small amounts of posi-tron-emitter-labelled biologic molecules. Various radiotracers are available for neuro-logical, cardiological, and oncological applications in the clinic and in research proto-cols. This overview describes the basic principles, technology, and recent develop-ments in PET, followed by a section on the development of a tomograph with ava-lanche photodiodes dedicated for small animal imaging as an example of efforts in the domain of high resolution tomographs.

  15. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    International Nuclear Information System (INIS)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176 Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176 Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  16. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    Science.gov (United States)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  17. Positron Emission Tomography: state of the art and future developments

    International Nuclear Information System (INIS)

    Pizzichemi, M.

    2016-01-01

    Positron emission tomography (PET) plays a fundamental role in medical imaging, with a wide range of applications covering, among the others, oncology, neurology and cardiology. PET has undergone a steady technological evolution since its introduction in mid 20th century, from the development of 3D PET in the late 1980s, to the invention of PET/CT in the 1990s and more recently with the introduction of PET/MR scanners. The current research topics aiming to develop the next generation of PET scanners are summarized in this paper, focusing on the efforts to increase the sensitivity of the detectors, as long as improving their timing, spatial and energy resolutions, with the final goal of reducing the amount of radioactive dose received by the patients and the duration of the exams while improving at the same time the detectability of lesions.

  18. Diagnostic Performance of Fluorine-18-Fluorodeoxyglucose Positron Emission Tomography in the Postchemotherapy Management of Patients with Seminoma: Systematic Review and Meta-Analysis

    OpenAIRE

    Giorgio Treglia; Ramin Sadeghi; Salvatore Annunziata; Carmelo Caldarella; Francesco Bertagna; Luca Giovanella

    2014-01-01

    Objective. To meta-analyze published data about the diagnostic performance of fluorine-18-Fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the postchemotherapy management of patients with seminoma. Methods. A comprehensive literature search of studies published through January 2014 on this topic was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity and specificity, positive and negative predicti...

  19. Thalamic glucose metabolism in temporal lobe epilepsy measured with 18F-FDG positron emission tomography (PET)

    NARCIS (Netherlands)

    Khan, N; Leenders, KL; Hajek, M; Maguire, P; Missimer, J; Wieser, HG

    1997-01-01

    Thalamic glucose metabolism has been studied in 24 patients suffering from temporal lobe epilepsy (TLE) using interictal F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET). A total of 17 patients had a unilateral TL seizure onset, 11 of these patients had a mesial temporal lobe

  20. Accuracy of FDG-PET-CT in the Diagnostic Work-up of Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Bruggink, J. L. M.; Glaudemans, A. W. J. M.; Saleem, B. R.; Meerwaldt, R.; Alkefaji, H.; Prins, T. R.; Start, R. H. J. A.; Zeebregts, C. J.

    Objectives: To investigate the diagnostic accuracy of fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) compared with computed tomography (CT) scanning and added value of fused FDG-PET CT in diagnosing vascular prosthetic graft infection. Design: Prospective cohort study with

  1. Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image.

    Science.gov (United States)

    Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik

    2015-01-01

    Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.

  2. Positron emission tomography takes lead

    International Nuclear Information System (INIS)

    Simms, R.

    1989-01-01

    Positron emission tomography (PET)'s ability to detect functional abnormalities before they manifest anatomically is examined and some of its most common applications are outlined. It is emphasised that when PET facility and Australian Nuclear Science and Technology Organization's national cyclotron are established at the Royal Prince Alfred Hospital, the availability of short-lived tracers such as oxygen 15, nitrogen 13 and fluorine 18 would improve the specificity of tests(e.g. for brain tumors or cardiac viability) further. Construction of the cyclotron will start shortly and is due to be completed and operating by the end of 1991

  3. Diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography in gallbladder cancer: A meta-analysis.

    Science.gov (United States)

    Annunziata, Salvatore; Pizzuto, Daniele Antonio; Caldarella, Carmelo; Galiandro, Federica; Sadeghi, Ramin; Treglia, Giorgio

    2015-10-28

    To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the evaluation of primary tumor in patients with gallbladder cancer (GBCa). A comprehensive literature search of studies published through 30(th) June 2014 regarding the role of (18)F-FDG PET and PET/CT in the evaluation of primary gallbladder cancer (GBCa) was performed. All retrieved studies were reviewed. Pooled sensitivity and specificity of (18)F-FDG PET or PET/CT in the evaluation of primary GBCa were calculated. The area under the summary receiving operator characteristics curve (AUC) was calculated to measure the accuracy of these methods. Sub-analyses considering the device used (PET vs PET/CT) were carried out. Twenty-one studies comprising 495 patients who underwent (18)F-FDG PET or PET/CT for suspicious GBCa were selected for the systematic review. The meta-analysis of 13 selected studies provided the following results: sensitivity 87% (95%CI: 82%-92%), specificity 78% (95%CI: 68%-86%). The AUC was 0.88. Improvement of sensitivity and specificity was observed when PET/CT was used. (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of primary tumor in GBCa patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.

  4. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    Science.gov (United States)

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by

  5. Impact of EBUS-TBNA on PET-CT Imaging of Mediastinal Nodes

    DEFF Research Database (Denmark)

    Sivapalan, Pradeesh; Naur, Therese Maria Henriette; Colella, Sara

    2017-01-01

    BACKGROUND: Positron emission tomography-computed tomography (PET-CT) with fluorine-18-fluorodeoxyglucose has a high sensitivity in detecting malignancy in patients suspected of lung cancer but a low specificity as inflammatory reactions can also result in metabolic activity. Furthermore, it is a......BACKGROUND: Positron emission tomography-computed tomography (PET-CT) with fluorine-18-fluorodeoxyglucose has a high sensitivity in detecting malignancy in patients suspected of lung cancer but a low specificity as inflammatory reactions can also result in metabolic activity. Furthermore......, it is assumed that invasive pulmonary procedures with biopsies from benign lesions can induce metabolic activity resulting in false-positive results. However, this hypothesis lacks solid evidence. We aimed to evaluate how often endobronchial ultrasound (EBUS) with biopsies from benign lesions are followed...

  6. Performance and limitations of positron emission tomography (PET) scanners for imaging very low activity sources.

    Science.gov (United States)

    Freedenberg, Melissa I; Badawi, Ramsey D; Tarantal, Alice F; Cherry, Simon R

    2014-02-01

    Emerging applications for positron emission tomography (PET) may require the ability to image very low activity source distributions in the body. The performance of clinical PET scanners in the regime where activity in the field of view is source in the NEMA scatter phantom), the BGO-based scanner significantly outperformed the LSO-based scanner. This was largely due to the effect of background counts emanating from naturally occurring but radioactive (176)Lu within the LSO detector material, which dominates the observed counting rate at the lowest activities. Increasing the lower energy threshold from 350 keV to 425 keV in an attempt to reduce this background did not significantly improve the measured NECR performance. The measured singles rate due to (176)Lu emissions within the scanner energy window was also found to be dependent on temperature, and to be affected by the operation of the CT component, making approaches to correct or compensate for the background more challenging. We conclude that for PET studies in a very low activity range, BGO-based scanners are likely to have better performance because of the lack of significant background. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic {sup 176}Lu radiation of PET detector

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Qingyang [School of Automation and Electrical Engineering, University of Science & Technology Beijing, Beijing 100083 (China); Ma, Tianyu; Wang, Shi; Liu, Yaqiang [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Gu, Yu, E-mail: guyu@ustb.edu.cn [School of Automation and Electrical Engineering, University of Science & Technology Beijing, Beijing 100083 (China); Dai, Tiantian, E-mail: maxinedtt@163.com [Department of Radiation Oncology, China-Japan Friendship Hospital, Beijing 100029 (China)

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic {sup 176}Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic {sup 176}Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  8. Positron emission tomography in drug development and drug evaluation

    NARCIS (Netherlands)

    Paans, AMJ; Vaalburg, W

    2000-01-01

    Positron Emission Tomography (PET) is an imaging modality which can determine biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labeled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation

  9. Case report: PET/CT, a cautionary tale

    International Nuclear Information System (INIS)

    Wang, Jayson; Cook, Gary; Frank, John; Dina, Roberto; Livni, Naomi; Lynn, John; Fleming, William; Seckl, Michael J

    2007-01-01

    The use of combined positron emission tomography/computerised tomography (PET/CT) scanners in oncology has been shown to improve the staging of tumours and the detection of relapses. However, mis-registration errors are increasingly recognised to be a common pitfall of PET/CT studies. We report a patient with a germ cell tumour of the testis, who underwent a PET/CT scan to detect the site of relapse with a view to surgical removal. However, the PET/CT scan mislocalised the tumour site to be within the T2 vertebral body. A subsequent endoscopic ultrasound scan however showed the tumour to be anterior to the vertebral body, which was confirmed at surgery. In this report, we highlight the artefactual mislocalisation errors which may occur with PET/CT imaging, and the need to review and verify these scans

  10. Cervical Lymph Node Metastases of Unknown Origin: Primary Tumor Detection with Whole-Body Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Nassenstein, K.; Veit-Haibach, P.; Stergar, H.; Gutzeit, A.; Freudenberg, L.; Kuehl, H.; Fischer, M.; Barkhausen, J.; Bockisch, A.; Antoch, G.

    2007-01-01

    Background: Identification of primary tumor in patients with cervical lymph node metastasis of unknown primary (MUO) has a great impact on therapy approach and potentially on patient prognosis. Purpose: To assess the diagnostic accuracy of combined positron emission tomography (PET)/computer tomography (CT) for primary tumor detection in cervical metastases of unknown origin compared to PET, CT, and PET+CT side-by-side evaluation. Material and Methods: 39 consecutive patients (eight women, 31 men; mean age 59.9±11.2 years) with MUO were enrolled in this study. PET/CT images were obtained 1 hour after injection of 350 MBq of fluorodeoxyglucose. Oral and intravenous contrast agents were administered in all patients to ensure diagnostic CT data. Fused PET/CT data were evaluated for primary tumor detection. Diagnostic accuracy was calculated and compared with CT alone, PET alone, and side-by-side PET+CT evaluation. Statistical analysis of differences in diagnostic performance between the different imaging procedures was based on the McNemar test. Results: Fused PET/CT depicted the primary tumor in 11 of 39 (28%) patients. In 28 (72%) patients, the primary tumor remained occult. CT revealed the primary in five (13%), PET alone in 10 (26%), and side-by-side evaluation of PET+CT in 10 (26%) of 39 patients. Statistical analysis showed no significant differences between the imaging modalities. Conclusion: PET, side-by-side PET+CT, and PET/CT revealed similar detection rates for primary tumors in cervical MUO patients. Therefore, cervical metastases of an unknown primary may be assessed with either of these imaging modalities. Detection rates with CT were substantially lower. Thus, inclusion of functional data for assessment of cervical MUO patients must be recommended

  11. Comparison of five segmentation tools for 18F-fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer.

    NARCIS (Netherlands)

    Schinagl, D.A.X.; Vogel, W.V.; Hoffmann, A.L.; Dalen, J.A. van; Oyen, W.J.G.; Kaanders, J.H.A.M.

    2007-01-01

    PURPOSE: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with (18)F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may

  12. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  13. PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan

    Energy Technology Data Exchange (ETDEWEB)

    Wong, K.; Rahill, J.; Cleary, K. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Petrillo, S.; Earl-Graef, D. [Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Banovac, F.; Levy, E. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Shekhar, R. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    2007-06-15

    Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

  14. Lung Hot Spot Without Corresponding Computed Tomography Abnormality on Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Artifactual or Real, Iatrogenic or Pathologic?

    Science.gov (United States)

    Liu, Yiyan

    Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Accuracy in the Staging of Non-Small Cell Lung Cancer: Review and Cost-Effectiveness

    International Nuclear Information System (INIS)

    Gómez León, Nieves; Escalona, Sofía; Bandrés, Beatriz; Belda, Cristobal; Callejo, Daniel; Blasco, Juan Antonio

    2014-01-01

    Aim of the performed clinical study was to compare the accuracy and cost-effectiveness of PET/CT in the staging of non-small cell lung cancer (NSCLC). Material and Methods. Cross-sectional and prospective study including 103 patients with histologically confirmed NSCLC. All patients were examined using PET/CT with intravenous contrast medium. Those with disease stage ≤IIB underwent surgery (n = 40). Disease stage was confirmed based on histology results, which were compared with those of PET/CT and positron emission tomography (PET) and computed tomography (CT) separately. 63 patients classified with ≥IIIA disease stage by PET/CT did not undergo surgery. The cost-effectiveness of PET/CT for disease classification was examined using a decision tree analysis. Results. Compared with histology, the accuracy of PET/CT for disease staging has a positive predictive value of 80%, a negative predictive value of 95%, a sensitivity of 94%, and a specificity of 82%. For PET alone, these values are 53%, 66%, 60%, and 50%, whereas for CT alone they are 68%, 86%, 76%, and 72%, respectively. Incremental cost-effectiveness of PET/CT over CT alone was €17,412 quality-adjusted life-year (QALY). Conclusion. In our clinical study, PET/CT using intravenous contrast medium was an accurate and cost-effective method for staging of patients with NSCLC

  16. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Accuracy in the Staging of Non-Small Cell Lung Cancer: Review and Cost-Effectiveness

    International Nuclear Information System (INIS)

    Leon, N.G.; Bandrs, B.; Escalona, S.; Callejo, D.; Blasco, J.A.; Belda, C.; Blasco, J.A.

    2014-01-01

    Aim of the performed clinical study was to compare the accuracy and cost-effectiveness of PET/CT in the staging of non-small cell lung cancer (NSCLC). Material and Methods. Cross-sectional and prospective study including 103 patients with histologically confirmed NSCLC. All patients were examined using PET/CT with intravenous contrast medium. Those with disease stage ≤IIB underwent surgery (η=40). Disease stage was confirmed based on histology results, which were compared with those of PET/CT and positron emission tomography (PET) and computed tomography (CT) separately. 63 patients classified with ≥IIIA disease stage by PET/CT did not undergo surgery. The cost-effectiveness of PET/CT for disease classification was examined using a decision tree analysis. Results. Compared with histology, the accuracy of PET/CT for disease staging has a positive predictive value of 80%, a negative predictive value of 95%, a sensitivity of 94%, and a specificity of 82%. For PET alone, these values are 53%, 66%, 60%, and 50%, whereas for CT alone they are 68%, 86%, 76%, and 72%, respectively. Incremental cost-effectiveness of PET/CT over CT alone was €17,412 quality-adjusted life-year (QALY). Conclusion. In our clinical study, PET/CT using intravenous contrast medium was an accurate and cost-effective method for staging of patients with NSCLC

  17. Advantages of 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography in detecting post cardiac surgery infections.

    Science.gov (United States)

    Adjtoutah, Djamel; Azhari, Alaa; Larabi, Youcef; Dorigo, Enrica; Merlin, Charles; Marcaggi, Xavier; Nana, Armel Simplice; Camilleri, Lionel; Azarnoush, Kasra

    2014-01-01

    The 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) offers an excellent negative predictive value. Consequently, it is a reliable tool for excluding an infectious phenomenon in case of negativity. In case of persistent fever of unknown origin after cardiac surgery and in combination with other bacteriological examinations and medical imaging, we can rely on FDG-PET/CT to confirm or eliminate deep infections and prosthetic endocarditis. For this reason, FDG-PET/CT should be considered among the examinations to be performed in case of suspected infection after cardiac surgery. We have reported the case of a 76-year-old man who presented with a fever of unknown origin and recurrent septic shocks after a biological Bentall procedure combined with left anterior descending (LAD) coronary artery revascularization by the left internal thoracic artery. We performed a FDG-PET/CT which showed external iliac vein and right common femoral vein hyperfixation with infiltration of adjacent soft tissues, highly suspected to be an infectious process. The aim of this case report is to show that FDG-PET/CT, in combination with other bacteriological examinations and medical imaging, can be extremely helpful in detecting deep infectious sources, even during the early postoperative period.

  18. Positron emission tomography combined with computed tomography for diagnosis of synchronous and metachronous tumors

    International Nuclear Information System (INIS)

    Zlatareva, D.; Garcheva, M.; Hadjiiska, V.

    2013-01-01

    Full text: Introduction: Positron emission tomography combined computed tomography (PET/CT) has proved to be the method of choice in oncology for diagnosis and staging, planning and determining the effect of treatment. Aim of the study was to determine the diagnostic capabilities of PET/CT for the detection of synchronous and metachronous tumors. Materials and Methods: The study was conducted with 18F FDG on Discovery, GE Healthcare under standard protocol. 18F FDG is dosed per kg body weight applying before a meal in blood sugar within reference values. The survey was conducted 60 min after application, in addition to visual assessment using quantitative indicators. For a period of a year (2012) 1408 patients were studied. In 11 (2 men, 9 women) of them synchronous and metachronous unsuspected tumors were found. Results: The most common as the second tumors are found processes in the head and neck, followed by lung cancer and colorectal cancer. In four of the cases operational or histological verification was made. In others cases due to refusal or advanced disease indications for systemic therapy the verification wasn't made. Diagnosis of the second tumor has changed the approach to patients as the therapeutic effect was detected at 3 patients over a period of nine months by repeated PET/CT study. Conclusion: The hybrid PET/CT, combining information about structural changes (CT) and metabolic changes (PET) plays an important role in the diagnosis of synchronous and metachronous tumors. This can significantly change the therapeutic management and prognosis of patients

  19. Attenuation correction in positron emission tomography: Quality control and performance evaluation

    International Nuclear Information System (INIS)

    Nalis, J.; Courbon, F.; Brillouet, S.; Marre, D.; Serre, D.; Colin, V.; Caselles, O.; Flouzat, G.

    2007-01-01

    Objective: The aim of this study is to evaluate the performance of the Computed Tomography based Attenuation Correction (CTAC) for Positron Emission Tomography (PET) data. Attenuation maps containing linear attenuation coefficients at 511 keV (LAC 511 keV ) are calculated by trilinear conversion of Hounsfield Units (HU) obtained from CT slices after matrix size-reduction and Gaussian filtering. Our work focusses on this trilinear conversion. Materials and methods: CT slices of an electron density phantom. composed of 17 cylindrical inserts made of different tissue-equivalent materials, were acquired using a Discovery ST4 PET-CT. Data were processed with a customized version of CT quality control software, giving automatically the experimental conversion function: LAC 511 keV =f(HU). Furthermore, data from patient datasets were assessed using both smoothed CT slices and attenuation maps. Results: LAC 511 keV extracted from phantom data are in good correlation with the expected theoretical values, except for the standard 10 mm diameter dense bone insert, where the obtained CTAC values are underestimated, Assuming a sample size issue, similar acquisitions were performed with a special 30 mm-diameter dense bone insert, confirming the underestimation as a consequence of the sample size. (authors)

  20. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by {sup 18}F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Masala, Salvatore; Bartolucci, Alberto D.; Mammucari, Matteo; Simonetti, Giovanni [University Hospital Tor Vergata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy); Schillaci, Orazio; Calabria, Ferdinando [University Hospital Tor Vergata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy); I.R.C.C.S. Neuromed, Department of Nuclear Medicine and Neuroradiology, Pozzilli (Italy); Policlinico Tor Vegata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy)

    2011-02-15

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. {sup 18}F-FDG positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) is a single technique of imaging that provides in a ''single step'' both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV{sub max}) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV{sub max} value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation. (orig.)

  1. Cobalt-55 positron emission tomography in recurrent ischaemic stroke

    NARCIS (Netherlands)

    De Reuck, J; Santens, P; Keppens, J; De Bleecker, J; Strijckmans, K; Goethals, P; Lemahieu, [No Value; Korf, J

    The present study investigates if Cobalt-55 (Co-55) positron emission tomography (PET) allows us to distinguish and detect recent, recurrent strokes in patients who had already suffered a previous infarct in the same vascular territory. Fourteen patients with recurrent strokes underwent a Co-55 PET

  2. Positron emission tomography in presurgical diagnosis of partial epilepsies

    International Nuclear Information System (INIS)

    Hajek, M.; Leenders, K.L.; Wieser, H.G.

    1992-01-01

    We present results of studies in which positron emission tomography was applied to the presurgical evaluation of epileptics. Emphasis is placed on results of PET studies with various tracers in partial epilepsies and on the use of PET in age-related epileptic syndromes in children. (orig.) [de

  3. FDG PET/CT imaging in canine cancer patients

    DEFF Research Database (Denmark)

    Hansen, Anders Elias; McEvoy, Fintan; Engelholm, Svend Aage

    2011-01-01

    2-Deoxy-2-[¹⁸F]fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) is becoming increasingly available as an imaging modality in veterinary medicine. The purpose of this study was to report semiquantitative standard uptake values (SUV) of malignant and nonmalignant tissues...

  4. Detection of Thyroid Metastasis pf Renal Transitional Cell Carcinoma Using FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Il; Kim, Yu Kyeong; Kim, Sang Eun [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of); Lee, Jong Jin [Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of); Paik, Jin Ho [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of)

    2011-06-15

    A 69 year old man who was diagnosed with renal transitional cell carcinoma (TCC) underwent F 18 fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET/CT) for detecting recurrence after chemotherapy. FDG PET/CT revealed multiple new hypermetabolic lesions in many places, including the right thyroid gland. Biopsy of the thyroid lesion was performed,and a diagnosis of metastatic TCC was made. We could detect thyroid metastasis of renal TCC by FDG PET/CT.

  5. Fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: comparison with surgicopathological findings

    International Nuclear Information System (INIS)

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. We have done meta-analysis with an objective to evaluate the efficacy of FDG PET/CT and its current clinical role in early stage and operable cervical cancer. Studies in which FDG PET/CT was performed before surgery in patients with early stage cervical cancers were included for analysis. PET findings were confirmed with histopathological diagnosis rather than clinical follow-up. The current data suggest that FDG PET/CT is suboptimal in nodal staging in early stage cervical cancer

  6. Fluorodeoxyglucose positron emission tomography?computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: Comparison with surgicopathological findings

    OpenAIRE

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Introduction: Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. Objectiv...

  7. A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain.

    Science.gov (United States)

    Cho, Hanna; Kim, Jin Su; Choi, Jae Yong; Ryu, Young Hoon; Lyoo, Chul Hyoung

    2014-01-01

    We developed a new computed tomography (CT)-based spatial normalization method and CT template to demonstrate its usefulness in spatial normalization of positron emission tomography (PET) images with [(18)F] fluorodeoxyglucose (FDG) PET studies in healthy controls. Seventy healthy controls underwent brain CT scan (120 KeV, 180 mAs, and 3 mm of thickness) and [(18)F] FDG PET scans using a PET/CT scanner. T1-weighted magnetic resonance (MR) images were acquired for all subjects. By averaging skull-stripped and spatially-normalized MR and CT images, we created skull-stripped MR and CT templates for spatial normalization. The skull-stripped MR and CT images were spatially normalized to each structural template. PET images were spatially normalized by applying spatial transformation parameters to normalize skull-stripped MR and CT images. A conventional perfusion PET template was used for PET-based spatial normalization. Regional standardized uptake values (SUV) measured by overlaying the template volume of interest (VOI) were compared to those measured with FreeSurfer-generated VOI (FSVOI). All three spatial normalization methods underestimated regional SUV values by 0.3-20% compared to those measured with FSVOI. The CT-based method showed slightly greater underestimation bias. Regional SUV values derived from all three spatial normalization methods were correlated significantly (p normalization may be an alternative method for structure-based spatial normalization of [(18)F] FDG PET when MR imaging is unavailable. Therefore, it is useful for PET/CT studies with various radiotracers whose uptake is expected to be limited to specific brain regions or highly variable within study population.

  8. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  9. Brain Positron Emission Tomography-Computed Tomography Gender Differences in Tinnitus Patients.

    Science.gov (United States)

    Shlamkovich, Nathan; Gavriel, Haim; Eviatar, Ephraim; Lorberboym, Mordechay; Aviram, Eliad

    2016-10-01

    Increased metabolism in the left auditory cortex has been reported in tinnitus patients. However, gender difference has not been addressed. To assess the differences in Positron emission tomography-computed tomography (PET-CT) results between the genders in tinnitus patients. Retrospective cohort. Included were patients referred to our clinic between January 2011 and August 2013 who complained of tinnitus and underwent fluorodeoxyglucose (FDG)-PET to assess brain metabolism. Univariate and multivariate nominal logistic regressions were used to evaluate the association between upper temporal gyrus (UTG; right and left) and gender. Included were 140 patients (87 males) with an average age of 52.5 yr (median = 53.1). Bilateral tinnitus was found in 85 patients (60.7%), left sided in 30 (21.4%), and right sided in 21(15%). Increased uptake in the UTG was found in 60% of the patients on either side. Males had a statistically significant increased uptake in the UTG in those with unilateral tinnitus and in the entire population. We present the largest study reported so far on tinnitus patients who have undergone FDG-PET-CT. We found a statistically significant difference between the genders in FDG uptake by the UTG. Further investigations should be undertaken to reveal the etiologies for these differences and to assess different therapeutic protocols according to gender. American Academy of Audiology

  10. Infective endocarditis detected by 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography in a patient with occult infection

    Directory of Open Access Journals (Sweden)

    Chia-Lu Yeh

    2011-11-01

    Full Text Available Integrated 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG PET/CT has been clinically used to detect infectious lesions. We present a case with pyrexia and bacteremia of unknown origin. Whole body FDG PET/CT was arranged to look for an occult source of infection and it revealed a focal lesion with increased FDG uptake in the mitral valve area. Under suspicion of infective endocarditis, transthoracic echocardiography was repeated and then the presence of linear vegetation over the calcified mitral annulus was confirmed. Ultimately, definite infective endocarditis was diagnosed according to the Duke criteria. The patient recovered after the antibiotic therapy. In our case, FDG PET/CT can help to localize the exact site of occult infection, thereby guiding additional testing and facilitating timely definitive diagnosis and therapy.

  11. {sup 18}F-fluorodeoxyglucose positron emission tomography in uterine carcinosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Kung-Chu; Yen, Tzu-Chen [Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Nuclear Medicine and Molecular Imaging Center, Taoyuan (China); Lai, Chyong-Huey; Wu, Tzu-I; Chang, Ting-Chang; Huang, Huei-Jean [Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Division of Gynecologic Oncology, Department of Obstetrics and Gynecology, Kueishan, Taoyuan (China); Ng, Koon-Kwan; Lin, Gigin [Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Medical Imaging and Intervention, Taoyuan (China); Wang, Chun-Chieh [Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Radiation Oncology, Taoyuan (China); Hsueh, Swei [Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Pathology, Taoyuan (China)

    2008-03-15

    Uterine carcinosarcomas clinically confined to the uterus usually harbor occult metastases. We conducted a pilot study to evaluate the value of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in uterine carcinosarcoma. Patients with histologically confirmed uterine carcinosarcoma were enrolled. Abdominal and pelvic magnetic resonance imaging (MRI)/whole-body computed tomography (CT) scan, and whole-body {sup 18}F-FDG PET or PET/CT were undertaken for primary staging, evaluating response, and restaging/post-therapy surveillance. The clinical impact of {sup 18}F-FDG PET was determined on a scan basis. A total of 19 patients were recruited and 31 {sup 18}F-FDG PET scans (including 8 scans performed on a PET/CT scanner) were performed. Positive impacts of scans were found in 36.8% (7/19) for primary staging, 66.7% (2/3) for monitoring response, and 11.1% (1/9) for restaging/post-therapy surveillance. PET excluded falsely inoperable disease defined by MRI in two patients. Aggressive treatment applying to three patients with PET-defined resectable stage IVB disease seemed futile. Two patients died of disease shortly after salvage therapy restaged by PET. With PET monitoring, one stage IVB patient treated by targeted therapy only was alive with good performance. Using PET did not lead to improvement of overall survival of this series compared with the historical control (n = 35) (P = 0.779). The preliminary results suggest that {sup 18}F-FDG PET is beneficial in excluding falsely inoperable disease for curative therapy and in making a decision on palliation for better quality of life instead of aggressive treatment under the guidance of PET. PET seems to have limited value in post-therapy surveillance or restaging after failure. (orig.)

  12. Distributed Microprocessor Automation Network for Synthesizing Radiotracers Used in Positron Emission Tomography [PET

    Science.gov (United States)

    Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.

    1984-09-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)

  13. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  14. Feasibility of breathing-adapted PET/CT imaging for radiation therapy of Hodgkin lymphoma

    DEFF Research Database (Denmark)

    Aznar, M C; Andersen, Flemming; Berthelsen, A K

    2011-01-01

    Aim: Respiration can induce artifacts in positron emission tomography (PET)/computed tomography (CT) images leading to uncertainties in tumour volume, location and uptake quantification. Respiratory gating for PET images is now established but is not directly translatable to a radiotherapy setup....... in PET/CT images. These results suggest that advanced therapies (such as SUV-based dose painting) will likely require breathing-adapted PET images and that the relevant SUV thresholds are yet to be investigated....

  15. Focal Colonic FDG Activity with PET/CT: Guidelines for Recommendation of Colonoscopy

    OpenAIRE

    Liu, Tianye; Behr, Spencer; Khan, Sana; Osterhoff, Robert; Aparici, Carina Mari

    2015-01-01

    Focal 18F-fluorodeoxyglucose (FDG) colonic activity can be incidentally seen in positron emission tomography/computed tomography (PET/CT) scans. Its clinical significance is still unclear. The purpose of this study was to assess the significance of focal FDG activity in PET/CT scans by correlating the imaging findings to colonoscopy results, and come up with some guidelines for recommendation of follow-up colonoscopy. A total of 133 patients who underwent both 18F-FDG PET/CT for different onc...

  16. Non-oncological positron emission tomography (PET): brain imaging; La tomographie par emission de positons (TEP) hors oncologie: l'exploration du cerveau

    Energy Technology Data Exchange (ETDEWEB)

    Lomena, F. [Centro de Diagnostico por la imagen (CDIC), Hospital Clinic, Servicio de medicina nuclear, Barcelona (Spain)

    2008-10-15

    Positron emission tomography (PET) allows evaluation of the central nervous system function. Imaging of regional cerebral blood flow and metabolism, and of several neurotransmission systems may be obtained using PET. PET quantification is accurate and has good test-retest reliability. For research purposes, PET has been used to study brain physiology, to explore neurological and psychiatric diseases pathophysiology and for the new drugs research and development. F.D.G. is the only PET radioligand with clinical application. Following criteria of evidence-based medicine, the clinical indications of F.D.G.-PET are: evaluation of treated gliomas, pre surgical study of partial refractory epilepsy and diagnosis of Alzheimer's disease when it is impossible to differentiate clinically from fronto-temporal dementia.

  17. 18F-fluorodeoxyglucose positron emission tomography/computed tomography for primary thyroid langerhans histiocytosis: A case report and literature review

    International Nuclear Information System (INIS)

    Long, Qi; Shaoyan, Wang; Hui, Wang

    2015-01-01

    Langerhans cell histiocytosis (LCH) is a rare clonal proliferative disease, with an incidence rate of 4.0–5.4/1 million individuals. LCH encompasses a spectrum of disorders with diverse clinical presentations ranging from a single organ to multiple organ involvement. LCH rarely involves the thyroid gland. We presented a case with LCH of thyroid gland. The patient had painless progressive neck enlargement and then diabetes insipidus. Ultrasonic scan and magnetic resonance imaging scan revealed nodular goiter and pituitary stalk enlargement, respectively. Histopathological analysis revealed features of histiocytoid cells. 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) was performed in order to rule out the presence of whole body infiltration. 18F-FDG PET/CT also demonstrated increased uptake in the thickening pituitary stalk and maxillofacial skin lesion, in addition to the bilateral thyroid nodules, CT showed the left lung nodule and the skull destruction without 18F-FDG uptake. This report emphasizes the role of 18F-FDG PET/CT in multiple organs involvement of patients with LCH

  18. Additional benefit of 18F-fluorodeoxyglucose integrated positron emission tomography/computed tomography in the staging of oesophageal cancer

    International Nuclear Information System (INIS)

    Gillies, R.S.; Middleton, M.R.; Maynard, N.D.; Bradley, K.M.; Gleeson, F.V.

    2011-01-01

    18 F-fluorodeoxyglucose positron emission tomography (FDG PET) has been shown to improve the accuracy of staging in oesophageal cancer. We assessed the benefit of PET/CT over conventional staging and determined if tumour histology had any significant impact on PET/CT findings. A retrospective cohort study, reviewing the results from 200 consecutive patients considered suitable for radical treatment, undergoing routine PET/CT staging comparing the results from CT and endoscopic ultrasound, as well as multi-disciplinary team records. Adenocarcinoma and squamous cell carcinoma were compared for maximum Standardised Uptake Value (SUV max ), involvement of local lymph nodes and distant metastases. PET/CT provided additional information in 37 patients (18.5%) and directly altered management in 34 (17%): 22 (11%) were upstaged; 15 (7.5%) were downstaged, 12 of whom (6%) received radical treatment. There were 11 false negatives (5.5%) and 1 false positive (0.5%). SUV max was significantly lower for adenocarcinoma than squamous cell carcinoma (median 9.1 versus 13.5, p = 0.003). Staging with PET/CT offers additional benefit over conventional imaging and should form part of routine staging for oesophageal cancer. Adenocarcinoma and squamous cell carcinoma display significantly different FDG-avidity. (orig.)

  19. Positron emission tomography applied to fluidization engineering

    NARCIS (Netherlands)

    Dechsiri, C; Ghione, A; van de Wiel, F; Dehling, HG; Paans, AMJ; Hoffmann, AC

    The movement of particles in a laboratory fluidized bed has been studied using Positron Emission Tomography (PET). With this non-invasive technique both pulses of various shapes and single tracer particles were followed in 3-D. The equipment and materials used made it possible to label actual bed

  20. The clinical application of PET/CT: a contemporary review

    International Nuclear Information System (INIS)

    Brady, Z.; Partridge, M.; Trapp, J.V.

    2008-01-01

    Full text: The combination of positron emission tomography (PET) scanners and x-ray computed tomography (CT) scanners into a single PET CT scanner has resulted in significant improvements in the diagnosis and staging of disease, particularly in the field of oncology. A decade on from the publication of the details of the first PET/CT scanner, we review the technology and applications of the modality. We examine the design aspects of combining two different imaging types into a single scanner, and the artefacts produced such as attenuation correction, motion and CT truncation artefacts. The article also provides a discussion and literature review of the applications of PET/CT to date, covering detection of tumours, radiotherapy treatment planning, patient management, and applications external to the field of oncology.

  1. Whole-body positron emission tomography using fluorodeoxyglucose for staging of lymphoma: effectiveness and comparison with computed tomography

    International Nuclear Information System (INIS)

    Stumpe, K.D.M.; Urbinelli, M.; Steinert, H.C.; Glanzmann, C.; Buck, A.; Schulthess, G.K. von

    1998-01-01

    The purpose of this study was to evaluate whole-body positron emission tomography (WB-PET) as a staging modality in Hodgkin's disease (HD) and non-Hodgkin lymphoma (NHL) and to compare it with computed tomography (CT) in a retrospective study. Seventy-one WB-PET studies using fluorodeoxyglucose (FDG) and 49 CT examinations were performed in 19 women and 31 men. Transaxial images were acquired and reformatted coronally and sagittally in PET. CT sections were obtained from the skull base to the pelvic floor. The written reports of the imaging data were compared with a reference standard constructed on the basis of all the data on the individual patients, including clinical follow-up of at least 6 months. The sensitivity and specificity of PET were, respectively, 86% and 96% for HD (n=53), and 89% and 100% for NHL (n=18). For CT sensitivity and specificity were 81% and 41% for HD (n=33) and 86% and 67% for NHL (n=16). Differences between PET and CT sensitivities were not significant, while in HD there was a significant difference in the specificity of PET and CT examinations, mainly because CT was unable to distinguish between active or recurrent disease and residual scar tissue after therapy. FDG tumour uptake was found in high- as well as low-grade NHL patients. In conclusion, PET appears to be highly sensitive and specific for staging of lymphoma. It is at least as sensitive as CT, and more specific, particularly in patients undergoing restaging, where a well-recognized diagnostic dilemma in CT is the presence of a post-therapeutic residual mass. (orig.)

  2. PET/CT cardiology: an area whose boundaries are still out of sight

    Energy Technology Data Exchange (ETDEWEB)

    Lucignani, Giovanni [University of Milan and Unit of Molecular Imaging, Institute of Radiological Sciences, Division of Radiation Therapy, European Institute of Oncology, Milan (Italy)

    2006-05-15

    Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

  3. 2-deoxy-2-(18F)fluoro-D-glucose positron emission tomography/computed tomography imaging in paediatric oncology

    Institute of Scientific and Technical Information of China (English)

    John; Freebody; Eva; A; Wegner; Monica; A; Rossleigh

    2014-01-01

    Positron emission tomography(PET) is a minimally in-vasive technique which has been well validated for the diagnosis, staging, monitoring of response to therapy, and disease surveillance of adult oncology patients. Tra-ditionally the value of PET and PET/computed tomogra-phy(CT) hybrid imaging has been less clearly defined for paediatric oncology. However recent evidence has emerged regarding the diagnostic utility of these mo-dalities, and they are becoming increasingly important tools in the evaluation and monitoring of children with known or suspected malignant disease. Important indi-cations for 2-deoxy-2-(18F)fluoro-D-glucose(FDG) PET in paediatric oncology include lymphoma, brain tumours, sarcoma, neuroblastoma, Langerhans cell histiocytosis, urogenital tumours and neurofibromatosis type Ⅰ. This article aims to review current evidence for the use of FDG PET and PET/CT in these indications. Attention will also be given to technical and logistical issues, the description of common imaging pitfalls, and dosimetric concerns as they relate to paediatric oncology.

  4. Positron emission tomography: Physics, instrumentation, and image analysis

    International Nuclear Information System (INIS)

    Porenta, G.

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources. PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and userfriendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center. (author)

  5. Positron emission tomography and migraine

    International Nuclear Information System (INIS)

    Chabriat, H.

    1992-01-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT 2 serotonin receptors can be studied in migraine patients with PET

  6. Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

    International Nuclear Information System (INIS)

    Chi, Pai-Chun Melinda; Mawlawi, Osama; Luo Dershan; Liao Zhongxing; Macapinlac, Homer A.; Pan Tinsu

    2008-01-01

    Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET HCT /HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET ACT /ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV max ), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET HCT , and for all patients the artifact was removed or reduced in the corresponding PET ACT . The impact of respiration artifact was the worst for lesions less than 50 cm 3 and located below the dome of the diaphragm. For lesions in this group, the mean SUV max difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location

  7. Diagnostic accuracy of (18) F-methylcholine positron emission tomography/computed tomography for intra- and extrahepatic hepatocellular carcinoma.

    Science.gov (United States)

    Bieze, Matthanja; Klümpen, Heinz-Josef; Verheij, Joanne; Beuers, Ulrich; Phoa, Saffire S K S; van Gulik, Thomas M; Bennink, Roelof J

    2014-03-01

    Diagnosis of hepatocellular carcinoma (HCC) primarily involves imaging. The aim of this study was to assess the accuracy of (18) F-fluorocholine ((18) F-FCH) positron emission tomography (PET) for detection of HCC and evaluation of extent of disease. Patients with HCC >1 cm were included between 2009 and July 2011, and follow-up closed in February 2013. Diagnosis was based on American Association for the Study of Liver Diseases criteria, and all patients underwent (18) F-FCH PET/computed tomography (CT) at baseline before treatment, 6 underwent a second PET/CT posttreatment, and 1 a third during follow-up. Whole-body PET and low-dose CT imaging were performed 15 minutes after (18) F-FCH injection. Evaluation of imaging was done with standardized uptake value (SUV) ratios: SUV maximum of the lesion divided by the SUV mean of surrounding tissue. Statistical analyses included descriptive analyses, receiver operating characteristic curve, McNemar's test, and Kaplan-Meier's test at 5% level of significance. Twenty-nine patients revealed 53 intrahepatic lesions. In 48 of 53 lesions, (18) F-FCH PET was positive (SUVratio , 1.95 ± 0.66; sensitivity, 88%; specificity, 100%). PET/CT showed uptake in 18 extrahepatic lesions and no uptake in 3 lesions affirmed non-HCC lesions; all lesions were confirmed with additional investigation (accuracy, 100%). In 17 of 29 patients, additional lesions were found on PET/CT imaging, with implications for treatment in 15 patients. Posttreatment PET/CT showed identical results, compared with standard treatment evaluation. This study shows additional value of (18) F-FCH PET/CT for patients with HCC. (18) F-FCH PET/CT has implications for staging, management, and treatment evaluation because of accurate assessment of extrahepatic disease. © 2014 by the American Association for the Study of Liver Diseases.

  8. CT, Magnetic Resonance, and 18F-Fluorodeoxyglucose Positron Emission Tomography/CT Imaging Features of Mucosa-Associated Lymphoid Tissue Lymphoma Involving Medial Rectus Muscle: A Case Report

    International Nuclear Information System (INIS)

    Lee, Sang Kwon; Choe, Mi Sun

    2013-01-01

    We report a case of mucosa-associated lymphoid tissue (MALT) lymphoma involving the medial rectus muscle in a 47-year-old man along with CT, MRI, 18 F-fluorodeoxy-glucose positron emission tomography/CT ( 18 F-FDG PET/CT), and pathologic features. The lesion was manifested as a fusiform enlargement isolated to the right medial rectus muscle with involvement of its tendinous insertion. The lesion was isoattenuating to the brain on non-enhanced CT images, showing as isointense to gray matter on fast spin echo T1- and T2-weighted images with fat saturation, and showed homogeneous enhancement on contrast-enhanced CT and MR images. The maximum stan- dardized uptake value on 18 F-FDG PET/CT was 4.9 g/mL. The results of histological and immunohistochemical examinations of the specimen obtained by biopsy of the right medial rectus muscle were consistent with MALT lymphoma. It should be noted that the extraocular muscle (EOM) is a rare location for the involvement of MALT lympho- ma, and MALT lymphoma of the EOM may mimic thyroid orbitopathy.

  9. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  10. 18F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    International Nuclear Information System (INIS)

    London, Kevin; Stege, Claudia; Kaspers, Gertjan; Cross, Siobhan; Dalla-Pozza, Luciano; Onikul, Ella; Graf, Nicole; Howman-Giles, Robert

    2012-01-01

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV max and greater SUV max reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  11. Simulated annealing image reconstruction for positron emission tomography

    International Nuclear Information System (INIS)

    Sundermann, E.; Lemahieu, I.; Desmedt, P.

    1994-01-01

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors)

  12. Advanced Instrumentation for Positron Emission Tomography [PET

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  13. Early prosthetic aortic valve infection identified with the use of positron emission tomography in a patient with lead endocarditis.

    Science.gov (United States)

    Amraoui, Sana; Tlili, Ghoufrane; Sohal, Manav; Bordenave, Laurence; Bordachar, Pierre

    2016-12-01

    18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE). FDG PET/CT might be also useful to localize associated septic emboli in patients with LE. We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy. FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.

  14. Feasibility of breathing-adapted PET/CT imaging for radiation therapy of Hodgkin lymphoma

    DEFF Research Database (Denmark)

    Aznar, M C; Andersen, Flemming; Berthelsen, A K

    2011-01-01

    Aim: Respiration can induce artifacts in positron emission tomography (PET)/computed tomography (CT) images leading to uncertainties in tumour volume, location and uptake quantification. Respiratory gating for PET images is now established but is not directly translatable to a radiotherapy setup....... uptake in PET/CT images. These results suggest that advanced therapies (such as SUV-based dose painting) will likely require breathing-adapted PET images and that the relevant SUV thresholds are yet to be investigated....

  15. Computed tomography myocardial perfusion vs {sup 15}O-water positron emission tomography and fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Michelle C.; Dweck, Marc R.; Golay, Saroj K. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); Mirsadraee, Saeed; Weir, Nicholas W.; Fletcher, Alison; Lucatelli, Christophe; Reid, John H. [University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); MacGillivray, Tom; Van Beek, Edwin J.R.; Newby, David E. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); Cruden, Nicholas L.; Henriksen, Peter A.; Uren, Neal [Edinburgh Heart Centre, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); McKillop, Graham; Patel, Dilip [Department of Radiology, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); Lima, Joao A.C. [Johns Hopkins Hospital, Departments of Medicine and Radiology, Baltimore, MD (United States)

    2017-03-15

    Computed tomography (CT) can perform comprehensive cardiac imaging. We compared CT coronary angiography (CTCA) and CT myocardial perfusion (CTP) with {sup 15}O-water positron emission tomography (PET) and invasive coronary angiography (ICA) with fractional flow reserve (FFR). 51 patients (63 (61-65) years, 80 % male) with known/suspected coronary artery disease (CAD) underwent 320-multidetector CTCA followed by ''snapshot'' adenosine stress CTP. Of these 22 underwent PET and 47 ICA/FFR. Obstructive CAD was defined as CTCA stenosis >50 % and CTP hypoperfusion, ICA stenosis >70 % or FFR <0.80. PET hyperaemic myocardial blood flow (MBF) was lower in obstructive than non-obstructive territories defined by ICA/FFR (1.76 (1.32-2.20) vs 3.11 (2.44-3.79) mL/(g/min), P < 0.001) and CTCA/CTP (1.76 (1.32-2.20) vs 3.12 (2.44-3.79) mL/(g/min), P < 0.001). Baseline and hyperaemic CT attenuation density was lower in obstructive than non-obstructive territories (73 (71-76) vs 86 (84-88) HU, P < 0.001 and 101 (96-106) vs 111 (107-114) HU, P 0.001). PET hyperaemic MBF corrected for rate pressure product correlated with CT attenuation density (r = 0.579, P < 0.001). There was excellent per-patient sensitivity (96 %), specificity (85 %), negative predictive value (90 %) and positive predictive value (94 %) for CTCA/CTP vs ICA/FFR. CT myocardial attenuation density correlates with {sup 15}O-water PET MBF. CTCA and CTP can accurately identify obstructive CAD. (orig.)

  16. Low Accuracy of Computed Tomography and Positron Emission Tomography to Detect Lung and Lymph Node Metastases of Colorectal Cancer.

    Science.gov (United States)

    Guerrera, Francesco; Renaud, Stéphane; Schaeffer, Mickaël; Nigra, Victor; Solidoro, Paolo; Santelmo, Nicola; Filosso, Pier Luigi; Falcoz, Pierre-Emmanuel; Ruffini, Enrico; Oliaro, Alberto; Massard, Gilbert

    2017-10-01

    Minimally invasive surgery, stereotactic radiotherapy, and radiofrequency ablation are commonly proposed in the case of pulmonary colorectal-metastasis as alternatives to conventional open surgery. Preoperative imaging assessment by computed tomography (CT) scan and fluorodeoxyglucose positron emission tomography (FDG-PET) are critical to guide oncologic radical treatment. Our aim was to investigate the accuracy of CT and FDG-PET for the evaluation of the number of pulmonary colorectal metastases and thoracic lymph nodal involvement (LNI). Patients who underwent lung surgical resection for pulmonary colorectal metastases from 2004 to 2014 were analyzed. Concordance between histology, CT scan, and FDG-PET findings were assessed. Data of 521 patients were analyzed. Of those, FDG-PET was performed in 435 (83.5%). A moderate agreement between both CT scan (kappa index: 0.42) and FDG-PET (kappa index: 0.42) findings and the histologically proven number of metastases was observed. The number of histologically proven metastases was correctly discriminated in 61.7% of cases with CT scan and in 61.8% of cases with FDG-PET. Multiple metastases were discovered in 20.9% of clinical single metastasis cases with CT scan, and in 24.4% of those cases with FDG-PET. One hundred fifty patients (29.1%) presented with pathologic LNI. A poor agreement was observed between LNI and CT scan findings (kappa index: 0.02), and a weak agreement was observed concerning LNI and FDG-PET findings (kappa index: 0.39). Computed tomography and FDG-PET have limitations if the objective is to detect all malignant nodules and to discriminate the LNI in cases of pulmonary metastases of colorectal cancer. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. (18)F-FDG PET/CT in a rare case of Stewart-Treves syndrome

    DEFF Research Database (Denmark)

    Jensen, Mads Radmer; Friberg, Lars; Karlsmark, Tonny

    2011-01-01

    The aim of this article is to illustrate the possible applications of (18)F-fluorodeoxyglucose positron emission tomography/computer tomography ((18)F-FDG PET/CT) in chronic extremity lymphedema and its complications....

  18. The cerebral blood flow and metabolism for Broca's aphasia using positron emission tomography

    International Nuclear Information System (INIS)

    Kato, Toshiaki

    1987-01-01

    A total of 11 patients with Broca's aphasia (BA) underwent positron emission tomography (PET) with the purpose of investigating the responsible region and the symptomatic flow and metabolism thresholds for BA. Computed tomography (CT) was concurrently performed. In the group of 3 patients undergoing PET with C-11 glucose, both PET and CT provided abnormal findings in the region that is thought to be responsible for BA (Broca's area), including the cortex and subcortex in the anterior region to Sylvian fissure. The Broca's area in the remaining one was shown as low C-11 accumulation area on PET and as isodensity on CT. The second group, consisting of 8 BA patients and 30 control patients without BA, underwent PET using O-15 steady method. PET showed reduction of regional cerebral blood flow (rCBF) and oxygen metabolic rate (rCMRO 2 ) in the Broca's area in all BA patients. Computed tomography showed abnormal low density in the Broca's area in 3 patients, and abnormal findings in the basal ganglionic region and subcortex without evidence for abnormal low density in the Broca's area in the other 5 patients. Comparison of rCBF and rCMRO 2 in BA patients with those in control patients may show the symptomatic thresholds to be 20 - 27 ml/100 g/min for rCBF and 2.0 ml/100 g/min for rCMRO 2 . (Namekawa, K.)

  19. Positron emission tomography basic sciences

    CERN Document Server

    Townsend, D W; Valk, P E; Maisey, M N

    2003-01-01

    Essential for students, science and medical graduates who want to understand the basic science of Positron Emission Tomography (PET), this book describes the physics, chemistry, technology and overview of the clinical uses behind the science of PET and the imaging techniques it uses. In recent years, PET has moved from high-end research imaging tool used by the highly specialized to an essential component of clinical evaluation in the clinic, especially in cancer management. Previously being the realm of scientists, this book explains PET instrumentation, radiochemistry, PET data acquisition and image formation, integration of structural and functional images, radiation dosimetry and protection, and applications in dedicated areas such as drug development, oncology, and gene expression imaging. The technologist, the science, engineering or chemistry graduate seeking further detailed information about PET, or the medical advanced trainee wishing to gain insight into the basic science of PET will find this book...

  20. Measurement of brain pH with positron emission tomography

    International Nuclear Information System (INIS)

    Buxton, R.B.; Alpert, N.M.; Ackerman, R.H.; Wechsler, L.R.; Elmaleh, D.R.; Correia, J.A.

    1985-01-01

    With positron emission tomography (PET) it is now possible to measure local brain pH noninvasively in humans. The application of PET to the determination of pH is relatively new, so only a handful of papers on the subject have appeared in print. This chapter reviews the current strategies for measuring brain pH with PET, discuss methodological problems, and present initial results

  1. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    Science.gov (United States)

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E

    2016-03-01

    The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board-approved study. After a single F-FDG injection, patients consecutively underwent F-FDG PET[Fraction Slash]CT and F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on F-FDG PET/CT and F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for F-FDG PET/CT, F-FDG PET/MR, and F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between F-FDG PET/MR DWI and F-FDG PET/CT, 99.2% (κ, 0.96) between F-FDG PET/MR and F-FDG PET/CT, and 99.4% (κ, 0.97) between F-FDG PET/MR DWI and F-FDG PET/MR. There was a strong correlation between F-FDG PET/CT and F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax

  2. Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction

    International Nuclear Information System (INIS)

    Brady, Samuel L.; Shulkin, Barry L.

    2015-01-01

    Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV bw ) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV bw , background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake

  3. Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Brady, Samuel L., E-mail: samuel.brady@stjude.org [Division of Diagnostic Imaging, St. Jude Children’s Research Hospital, Memphis, Tennessee 38105 (United States); Shulkin, Barry L. [Nuclear Medicine and Department of Radiological Sciences, St. Jude Children’s Research Hospital, Memphis, Tennessee 38105 (United States)

    2015-02-15

    Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV{sub bw}) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV{sub bw}, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake.

  4. Magnetic resonance imaging-guided attenuation correction of positron emission tomography data in PET/MRI

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2018-01-01

    Synopsis Attenuation correction (AC) is one of the most important challenges in the recently introduced combined positron emission tomography/magnetic resonance imaging (PET/MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients (LACs) of the tissues and other components located in the PET field of view (FoV). MR-AC methods can be divided into three main categories: segmentation-, atlas- and PET-based. This review aims to provide a comprehensive list of the state of the art MR-AC approaches as well as their pros and cons. The main sources of artifacts such as body-truncation, metallic implants and hardware correction will be presented. Finally, this review will discuss the current status of MR-AC approaches for clinical applications. PMID:26952727

  5. Simulated annealing image reconstruction for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sundermann, E; Lemahieu, I; Desmedt, P [Department of Electronics and Information Systems, University of Ghent, St. Pietersnieuwstraat 41, B-9000 Ghent, Belgium (Belgium)

    1994-12-31

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors). 11 refs., 2 figs.

  6. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-07-01

    The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.

  7. {sup 18}F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    London, Kevin [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Paediatrics and Child Health, Sydney Medical School, Sydney, NSW (Australia); Stege, Claudia; Kaspers, Gertjan [VU Medical Centre, Divisions of Paediatric Oncology/Haematology, Amsterdam (Netherlands); Cross, Siobhan; Dalla-Pozza, Luciano [The Children' s Hospital at Westmead, Department of Oncology, Sydney (Australia); Onikul, Ella [The Children' s Hospital at Westmead, Department of Medical Imaging, Sydney (Australia); Graf, Nicole [The Children' s Hospital at Westmead, Department of Pathology, Sydney (Australia); Howman-Giles, Robert [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Imaging, Sydney Medical School, Sydney, NSW (Australia)

    2012-04-15

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV{sub max} and greater SUV{sub max} reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  8. Usefulness of {sup 18}F-FDG PET, combined FDG-PET/CT and EUS in diagnosing primary pancreatic carcinoma: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tang Shuang [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Huang Gang, E-mail: huang2802@163.com [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Liu Jianjun [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Liu Tao [Department of Orthopedics, Soochow University, Suzhou (China); Treven, Lyndal [Faculty of Public Health, University of Sydney, Sydney (Australia); Song Saoli; Zhang Chenpeng; Pan Lingling [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Zhang Ting [Department of Anesthesiology, Renji Hospital, Shanghai (China)

    2011-04-15

    The aim was to evaluate the diagnostic value of {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET), combined {sup 18}F-fluorodeoxyglucose-positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and endoscopic ultrasonography (EUS) in diagnosing patients with pancreatic carcinoma. MEDLINE, EMBASE, Cochrane library and some other databases, from January 1966 to April 2009, were searched for initial studies. All the studies published in English or Chinese relating to the diagnostic value of {sup 18}F-FDG PET, PET/CT and EUS for patients with pancreatic cancer were collected. Methodological quality was assessed. The statistic software called 'Meta-Disc 1.4' was used for data analysis. Results: 51 studies were included in this meta-analysis. The pooled sensitivity estimate for combined PET/CT (90.1%) was significantly higher than PET (88.4%) and EUS (81.2%). The pooled specificity estimate for EUS (93.2%) was significantly higher than PET (83.1%) and PET/CT (80.1%). The pooled DOR estimate for EUS (49.774) was significantly higher than PET (32.778) and PET/CT (27.105). SROC curves for PET/CT and EUS showed a little better diagnostic accuracy than PET alone. For PET alone, when interpreted the results with knowledge of other imaging tests, its sensitivity (89.4%) and specificity (80.1%) were closer to PET/CT. For EUS, its diagnostic value decreased in differentiating pancreatic cancer for patients with chronic pancreatitis. In conclusion, PET/CT was a high sensitive and EUS was a high specific modality in diagnosing patients with pancreatic cancer. PET/CT and EUS could play different roles during different conditions in diagnosing pancreatic carcinoma.

  9. Utility of interim and end-of-treatment PET/CT in peripheral T-cell lymphomas

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; Pedersen, Martin Bjerregård; Hutchings, Martin

    2015-01-01

    According to the updated guidelines for imaging in lymphoma, 18F-FDG positron emission tomography/computed tomography (PET/CT) is recommended for staging and evaluation of treatment response in FDG-avid lymphomas. The purpose of the study was to evaluate the utility of PET/CT in nodal peripheral T....../CT. Medical records were reviewed for baseline clinical and follow-up information. Staging, interim (I-PET), and end-of-treatment PET/CT (E-PET) studies were centrally reviewed, and reported using the Deauville 5-point score (DS). A total of 124 patients fulfilled the inclusion criteria. The median age was 58...

  10. CT, Magnetic Resonance, and {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/CT Imaging Features of Mucosa-Associated Lymphoid Tissue Lymphoma Involving Medial Rectus Muscle: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kwon; Choe, Mi Sun [Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report a case of mucosa-associated lymphoid tissue (MALT) lymphoma involving the medial rectus muscle in a 47-year-old man along with CT, MRI, 18 F-fluorodeoxy-glucose positron emission tomography/CT ( 18 F-FDG PET/CT), and pathologic features. The lesion was manifested as a fusiform enlargement isolated to the right medial rectus muscle with involvement of its tendinous insertion. The lesion was isoattenuating to the brain on non-enhanced CT images, showing as isointense to gray matter on fast spin echo T1- and T2-weighted images with fat saturation, and showed homogeneous enhancement on contrast-enhanced CT and MR images. The maximum stan- dardized uptake value on 18 F-FDG PET/CT was 4.9 g/mL. The results of histological and immunohistochemical examinations of the specimen obtained by biopsy of the right medial rectus muscle were consistent with MALT lymphoma. It should be noted that the extraocular muscle (EOM) is a rare location for the involvement of MALT lympho- ma, and MALT lymphoma of the EOM may mimic thyroid orbitopathy.

  11. Importance of PET/CT for imaging of colorectal cancer

    International Nuclear Information System (INIS)

    Meinel, F.G.; Schramm, N.; Graser, A.; Reiser, M.F.; Rist, C.; Haug, A.R.

    2012-01-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) has emerged as a very useful imaging modality in the management of colorectal carcinoma. Data from the literature regarding the role of PET/CT in the initial diagnosis, staging, radiotherapy planning, response monitoring and surveillance of colorectal carcinoma is presented. Future directions and economic aspects are discussed. Computed tomography (CT), magnetic resonance imaging (MRI) and FDG-PET for colorectal cancer and endorectal ultrasound for rectal cancer. Combined FDG-PET/CT. While other imaging modalities allow superior visualization of the extent and invasion depth of the primary tumor, PET/CT is most sensitive for the detection of distant metastases of colorectal cancer. We recommend a targeted use of PET/CT in cases of unclear M staging, prior to metastasectomy and in suspected cases of residual or recurrent colorectal carcinoma with equivocal conventional imaging. The role of PET/CT in radiotherapy planning and response monitoring needs to be determined. Currently there is no evidence to support the routine use of PET/CT for colorectal screening, staging or surveillance. To optimally exploit the synergy between morphologic and functional information, FDG-PET should generally be performed as an integrated FDG-PET/CT with a contrast-enhanced CT component in colorectal carcinoma. (orig.) [de

  12. Improving 18F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer's Disease Studies

    International Nuclear Information System (INIS)

    Knešaurek, Karin

    2015-01-01

    The goal was to improve Alzheimer's 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F FDG)-positron emission tomography (PET)/computed tomography (CT) imaging through application of a novel, hybrid Fourier-wavelet windowed Fourier transform (WFT) restoration technique, in order to provide earlier and more accurate clinical results. General Electric Medical Systems downward-looking sonar PET/CT 16 slice system was used to acquire studies. Patient data were acquired according the Alzheimer's disease Neuroimaging Initiative (ADNI) protocol. Here, we implemented Fourier-wavelet regularized restoration, with a Butterworth low-pass filter, order n = 6 and a cut-off frequency f = 0.35 cycles/pixel and wavelet (Daubechies, order 2) noise suppression. The original (PET-O) and restored (PET-R) ADNI subject PET images were compared using the Alzheimer's discrimination analysis by dedicated software. Forty-two PET/CT scans were used in the study. They were performed on eleven ADNI subjects at intervals of approximately 6 months. The final clinical diagnosis was used as a gold standard. For three subjects, the final clinical diagnosis was mild cognitive impairment and those 13 PET/CT studies were not included in the final comparison, as the result was considered as inconclusive. Using the reminding 29 PET/CT studies (23 AD and 6 normal), the sensitivity and specificity of the PET-O and PET-R were calculated. The sensitivity was 0.65 and 0.96 for PET-O and PET-R, respectively, and the specificity was 0.67 and 0.50 for PET-O and PET-R. The accuracy was 0.66 and 0.86 for PET-O and PET-R, respectively. The results of the study demonstrated that the accuracy of three-dimensional brain F-18 FDG PET images was significantly improved by Fourier-wavelet restoration filtering

  13. Functional cardiac imaging: positron emission tomography

    International Nuclear Information System (INIS)

    Mullani, N.A.; Gould, K.L.

    1984-01-01

    Dynamic cardiovascular imaging plays a vital role in the diagnosis and treatment of cardiac disease by providing information about the function of the heart. During the past 30 years, cardiovascular imaging has evolved from the simple chest x-ray and fluoroscopy to such sophisticated techniques as invasive cardiac angiography and cinearteriography and, more recently, to noninvasive cardiac CT scanning, nuclear magnetic resonance, and positron emission tomography, which reflect more complex physiologic functions. As research tools, CT, NMR, and PET provide quantitative information on global as well as regional ventricular function, coronary artery stenosis, myocardial perfusion, glucose and fatty acid metabolism, or oxygen utilization, with little discomfort or risk to the patient. As imaging modalities become more sophisticated and more oriented toward clinical application, the prospect of routinely obtaining such functional information about the heart is becoming realistic. However, these advances are double-edged in that the interpretation of functional data is more complex than that of the anatomic imaging familiar to most physicians. They will require an enhanced understanding of the physiologic and biochemical processes, as well as of the instrumentation and techniques for analyzing the data. Of the new imaging modalities that provide functional information about the heart, PET is the most useful because it quantitates the regional distribution of radionuclides in vivo. Clinical applications, interpretation of data, and the impact of PET on our understanding of cardiac pathophysiology are discussed. 5 figures

  14. Forced diuresis 18F-fluorodeoxyglucose positron emission tomography/contrast enhanced in detection of carcinoma of urinary bladder diverticulum

    International Nuclear Information System (INIS)

    Soundararajan, Ramya; Singh, Harmandeep; Arora, Saurabh; Nayak, Brusabhanu; Shamim, Shamim Ahmed; Bal, Chandrasekhar; Kumar, Rakesh

    2015-01-01

    Urinary bladder diverticular carcinomas are uncommon with a lesser incidence of 0.8–10% and its diagnosis still remains a challenge. Cystoscopy is the most reliable method, but evaluating diverticulum with narrow orifices is difficult. Before the initiation of appropriate treatment, proper detection of bladder diverticular carcinoma and its locoregional and distant sites of involvement is necessary. Here, we present a case of 48-year-old male with urinary bladder diverticular carcinoma detected by forced diuretic 18 F-fluorodeoxyglucose positron emission tomography/computerized tomography ( 18 F-FDG PET/CT). This case also highlights the significance of forced diuretic 18 F-FDG PET/CT in the detection, staging, and response evaluation of bladder diverticular carcinoma

  15. Analysis of human cerebral functions using positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Shibasaki, Takashi

    1984-01-01

    Positron emission tomography has two major advantages to analyse human cerebral functions in vivo. First, we can see the distribution of a variety of substance in the living (and doing something) human brain. Positron emitters, 11 C, 13 N, 15 O and 18 F, are made by medical cyclotron and are elements of natural substrates or easily tagged to substrate. Second, the distribution of the tracer is calculated to make a quantitative functional map in a reasonable spatial resolution over the entire brain in the same time. Not only cortical areas but also deeper structures show regional cerebral blood flow (rCBF) or local cerebral metabolic rates (LCMRs). Nowadays, PET is put to practical use for determination of mainly rCBF, LCMR for glucose (LCMRsub(glu)), LCMR for oxygen (LCMRsub(o2)) and regional cerebral blood volume (rCBV). There have been many other pilot studies, such as estimation of distribution of given neurotransmitters or modulators in the brain which also confirms the substances' role in the neuronal function, and observation of protein synthesis relating to memory function. (J.P.N.)

  16. Role of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in diagnosis and management of pancreatic cancer; comparison with multidetector row computed tomography, magnetic resonance imaging and endoscopic ultrasonography.

    Science.gov (United States)

    Ergul, N; Gundogan, C; Tozlu, M; Toprak, H; Kadıoglu, H; Aydin, M; Cermik, T F

    2014-01-01

    We aimed to analyze the contribution of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging to the diagnosis and management of pancreatic cancer compared with multidetector row computed tomography (MDCT), magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS). We retrospectively scanned the data of 52 patients who were referred for FDG PET/CT imaging for evaluation of pancreatic lesions greater than 10mm. The diagnostic performances of 4 imaging methods and the impact of PET/CT on the management of pancreatic cancer were defined. Pancreatic adenocarcinoma was diagnosed in 33 of 52 patients (63%), 15 patients had benign diseases of pancreas (29%), and 4 patients were normal (8%). Sensitivity and NPV of EUS and PET/CT were equal (100%) and higher than MDCT and MRI. Specificity, PPV and NPV of PET/CT were significantly higher than MDCT. However, sensitivities of two imaging methods were not significantly different. There was no significant difference between PET/CT and MRI and EUS for these values. When the cut-off value of SUVmax was 3.2, the most effective sensitivity and specificity values were obtained. PET/CT contributed to the management of pancreatic cancer in 30% of patients. FDG PET/CT is a valuable imaging method for the diagnosis and management of pancreatic cancer, especially when applied along with EUS as first line diagnostic tools. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  17. Contribution of positron emission tomography in pleural disease.

    OpenAIRE

    Duysinx, Bernard; Corhay, Jean-Louis; Larock, Marie-Paule; Withofs, Nadia; Bury, Thierry; Hustinx, Roland; Louis, Renaud

    2010-01-01

    INTRODUCTION: Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. BACKGROUND: PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumou...

  18. Positron emission tomography: a new paradigm in cancer management

    International Nuclear Information System (INIS)

    Paez Gutierrez, Diana Isabel; De los Reyes, Amelia; Llamas Olier, Augusto

    2007-01-01

    The National Cancer Institute (NCI) is currently building a positron emission tomography facility that will house a cyclotron and a PET fusion scanner. lt should be operational as of december 2007, being a cancer dedicated national referral center, the NCI should provide both positron-emitting radiopharmaceuticals and medical services to institutions and patients nationwide. PET technology provides metabolic information that has been documented to be useful in patient care. The properties of positron decay allow accurate imaging of the in vivo distribution of positron-emitting radiopharmaceuticals. a wide array of positron-emitting radiopharmaceuticals has been used to characterize multiple physiologic and pathologic states. The major clinical PET applications are in cancer patients using fluorine-18 fluorodeoxyglucose (FDG). FDG, an analogue of glucose, accumulates in most tumors in a greater amount than it does in normal tissue. PET is being used in diagnosis and follow-up of several malignancies, and the list of articles supporting its use continues to grow. in this article, the instrumentation aspects of PET are described and most of the clinical applications in oncology are described

  19. Influence of 2-(18F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography on recurrent ovarian cancer diagnosis and on selection of patients for secondary cytoreductive surgery

    DEFF Research Database (Denmark)

    Risum, Signe; Høgdall, Claus; Markova, Elena

    2009-01-01

    physical examination, US, or increasing cancer antigen 125 (CA125) level (>50 U/mL or >15% above baseline level). Recurrent OC was diagnosed 58 times in 52 patients. The sensitivities of US, CT, and PET/CT for diagnosing recurrence were 66% (P = 0.003), 81% (P = 0.0001), and 97% (P ...The objective of this prospective study was to compare the sensitivities and the specificities of combined 2-(F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT), abdominal/transvaginal ultrasound (US), and CT for diagnosing recurrent ovarian cancer (OC......) and to evaluate the influence of PET/CT on referral of patients with solitary recurrence to secondary cytoreductive surgery. From April 2005 to November 2007, 60 patients were consecutively included to PET/CT 68 times. The inclusion criteria were remission of 3 months or longer and recurrent OC suspected from...

  20. PET/CT Facility at Radiation Medicine Centre, BARC

    International Nuclear Information System (INIS)

    Baghel, Nawab Singh; Banerjee, Sharmila

    2017-01-01

    Positron Emission Tomography (PET) integrated with Computed Tomography in a single unit (PET/CT) has become an established and valued imaging modality in the clinical arena. Integrated PET/CT has been shown to be more accurate for lesion localisation and characterisation than either PET or CT alone. Image fusion brings together two image datasets with the intention of registering them as closely as possible. Generally, the two image datasets would have been produced on different types of medical imaging devices. Various problems can evolve when using two geographically remote imaging devices. To overcome this, in recent times there has been a move towards the integration of the two medical imaging devices into one physical unit. The use of one imaging unit to produce two different image datasets is known as hybrid imaging

  1. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... was to investigate the value of positron emission tomography using 2-[18F]fluoro-2-deoxy-D-glucose (FDG-PET) and combined FDG-PET/CT for the staging of HL patients, and the impact on the choice of treatment. DESIGN AND METHODS: Ninety-nine consecutive, prospectively included patients had FDG-PET and CT...

  2. Incidental detection of prostate-specific antigen-negative metastatic prostate cancer initially presented with solitary pulmonary nodule on fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Erdogan, Ezgi Basak; Buyukpinarbasili, Nur; Ziyade, Sedat; Akman, Tolga; Turk, Haci Mehmet; Aydin, Mehmet

    2005-01-01

    A 71-year-old male patient with solitary pulmonary nodule underwent fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) showing slightly increased FDG uptake in this nodule. In addition, PET/CT detected hypermetabolic sclerotic bone lesions in the right second rib and 7 th thoracic vertebrae, which were interpreted as possible metastases, and mildly increased FDG uptake in the prostate gland highly suspicious of malignancy. The patient's prostate-specific antigen (PSA) level was within normal range (3.8 ng/dL). The histopathological examination of the lung nodule and right second rib lesion proved metastases from prostate cancer, then the prostate biopsy-confirmed prostate adenocarcinoma. The unique feature of this case is to emphasize the importance of performing PET/CT for solitary pulmonary nodule in detecting PSA-negative metastatic prostate cancer. This case indicated that it should be kept in mind that, even if the PSA is negative, a lung metastasis of prostate cancer may be an underlying cause in patients evaluated for solitary pulmonary nodule by FDG PET/CT

  3. Clinical correlates of decreased anteroposterior metabolic gradients in positron emission tomography (PET) of schizophrenic patients

    International Nuclear Information System (INIS)

    DeLisi, L.E.; Buchsbaum, M.S.; Holcomb, H.H.

    1985-01-01

    The finding in schizophrenic patients of a reversal of the normal frontal to posterior pattern of brain metabolic activity with positron emission tomography (PET) is of interest, but its relevance to psychopathology is unknown. Using PET, the authors studied 21 patients with chronic schizophrenia and 21 age- and sex-matched control subjects. Although eight of the 21 patients and only one of the control subjects showed a relatively lower anteroposterior metabolic gradient, no clinical correlates of this finding were noted. In addition, cerebral atrophy, as determined by CAT scan, was not associated with this aberrant metabolic pattern

  4. Nonrigid Image Registration for Head and Neck Cancer Radiotherapy Treatment Planning With PET/CT

    International Nuclear Information System (INIS)

    Ireland, Rob H.; Dyker, Karen E.; Barber, David C.; Wood, Steven M.; Hanney, Michael B.; Tindale, Wendy B.; Woodhouse, Neil; Hoggard, Nigel; Conway, John; Robinson, Martin H.

    2007-01-01

    Purpose: Head and neck radiotherapy planning with positron emission tomography/computed tomography (PET/CT) requires the images to be reliably registered with treatment planning CT. Acquiring PET/CT in treatment position is problematic, and in practice for some patients it may be beneficial to use diagnostic PET/CT for radiotherapy planning. Therefore, the aim of this study was first to quantify the image registration accuracy of PET/CT to radiotherapy CT and, second, to assess whether PET/CT acquired in diagnostic position can be registered to planning CT. Methods and Materials: Positron emission tomography/CT acquired in diagnostic and treatment position for five patients with head and neck cancer was registered to radiotherapy planning CT using both rigid and nonrigid image registration. The root mean squared error for each method was calculated from a set of anatomic landmarks marked by four independent observers. Results: Nonrigid and rigid registration errors for treatment position PET/CT to planning CT were 2.77 ± 0.80 mm and 4.96 ± 2.38 mm, respectively, p = 0.001. Applying the nonrigid registration to diagnostic position PET/CT produced a more accurate match to the planning CT than rigid registration of treatment position PET/CT (3.20 ± 1.22 mm and 4.96 ± 2.38 mm, respectively, p = 0.012). Conclusions: Nonrigid registration provides a more accurate registration of head and neck PET/CT to treatment planning CT than rigid registration. In addition, nonrigid registration of PET/CT acquired with patients in a standardized, diagnostic position can provide images registered to planning CT with greater accuracy than a rigid registration of PET/CT images acquired in treatment position. This may allow greater flexibility in the timing of PET/CT for head and neck cancer patients due to undergo radiotherapy

  5. System immune response to vaccination on FDG-PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Mingos, Mark; Howard, Stephanie; Giaclone, Micholas; Kozono, David; Jacene, Heather [Brigham and Women' s Hospital, Boston (United States)

    2016-12-15

    A patient with newly diagnosed right lung cancer had transient 18F-fluorodeoxyglucose (FDG)-avid left axillary lymph nodes and intense splenic FDG uptake on positron emission tomography (PET)/computed tomography (CT). History revealed that the patient received a left-sided influenza vaccine 2-3 days before the examination. Although inflammatory FDG uptake in ipsilateral axillary nodes is reported, to our knowledge, this is the first report of visualization of the systemic immune response in the spleen related to the influenza vaccination on FDG-PET/CT. The history, splenic uptake and time course on serial FDG-PET/CT helped to avoid a false-positive interpretation for progressing lung cancer and alteration of the radiation therapy plan.

  6. System immune response to vaccination on FDG-PET/CT

    International Nuclear Information System (INIS)

    Mingos, Mark; Howard, Stephanie; Giaclone, Micholas; Kozono, David; Jacene, Heather

    2016-01-01

    A patient with newly diagnosed right lung cancer had transient 18F-fluorodeoxyglucose (FDG)-avid left axillary lymph nodes and intense splenic FDG uptake on positron emission tomography (PET)/computed tomography (CT). History revealed that the patient received a left-sided influenza vaccine 2-3 days before the examination. Although inflammatory FDG uptake in ipsilateral axillary nodes is reported, to our knowledge, this is the first report of visualization of the systemic immune response in the spleen related to the influenza vaccination on FDG-PET/CT. The history, splenic uptake and time course on serial FDG-PET/CT helped to avoid a false-positive interpretation for progressing lung cancer and alteration of the radiation therapy plan

  7. New developments in molecular imaging: positron emission tomography time-of-flight (TOF-PET); Nuevos desarrollos en imagen molecular: Tomografia por Emision de Positrones con Teimpo de Vuelo (TOF-PET)

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, P.; Couce, B.; Iglesias, A.; Lois, C.

    2011-07-01

    Positron Emission tomography (PET) in increasingly being used in oncology for the diagnosis and staging of disease, as well as in monitoring response to therapy. One of the last advances in PET is the incorporation of Time-of-Flight (TOF) information, which improves the tomographic reconstruction process and subsequently the quality of the final image. In this work, we explain the principles of PET and the fundamentals of TOF-PET. Clinical images are shown in order to illustrate how TOF-PET improves the detectability of small lesions, particularly in patients with high body mass index. (Author) 20 refs.

  8. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome

    International Nuclear Information System (INIS)

    Joshi, Prathamesh; Lele, Vikram

    2013-01-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of 123 I/ 131 I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with 68 Gallium- DOTA-DPhe 1 , Tyr 3 -octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA

  9. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome.

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram

    2013-04-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of (123)I/(131)I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with (68)Gallium- DOTA-DPhe(1), Tyr(3)-octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA.

  10. The Impact of Positron Emission Tomography/Computed Tomography in Edge Delineation of Gross Tumor Volume for Head and Neck Cancers

    International Nuclear Information System (INIS)

    Ashamalla, Hani; Guirgius, Adel; Bieniek, Ewa; Rafla, Sameer; Evola, Alex; Goswami, Ganesh; Oldroyd, Randall; Mokhtar, Bahaa; Parikh, Kapila

    2007-01-01

    Purpose: To study anatomic biologic contouring (ABC), using a previously described distinct halo, to unify volume contouring methods in treatment planning for head and neck cancers. Methods and Materials: Twenty-five patients with head and neck cancer at various sites were planned for radiation therapy using positron emission tomography/computed tomography (PET/CT). The ABC halo was used in all PET/CT scans to contour the gross tumor volume (GTV) edge. The CT-based GTV (GTV-CT) and PET/CT-based GTV (GTV-ABC) were contoured by two independent radiation oncologists. Results: The ABC halo was observed in all patients studied. The halo had a standard unit value of 2.19 ± 0.28. The mean halo thickness was 2.02 ± 0.21 mm. Significant volume modification (≥25%) was seen in 17 of 25 patients (68%) after implementation of GTV-ABC. Concordance among observers was increased with the use of the halo as a guide for GTV determination: 6 patients (24%) had a ≤10% volume discrepancy with CT alone, compared with 22 (88%) with PET/CT (p 3 in CT-based planning to 7.2 cm 3 in PET/CT-based planning (p < 0.001). Conclusions: Using the 'anatomic biologic halo' to contour GTV in PET/CT improves consistency among observers. The distinctive appearance of the described halo and its presence in all of the studied tumors make it attractive for GTV contouring in head and neck tumors. Additional studies are needed to confirm the correlation of the halo with presence of malignant cells

  11. Positron emission tomography in minor ischemic stroke using oxygen-15 steady-state technique

    International Nuclear Information System (INIS)

    Pozzilli, C.; Itoh, M.; Matsuzawa, T.; Fukuda, H.; Abe, Y.; Sato, T.; Takeda, S.; Ido, T.

    1987-01-01

    A study with positron emission tomography (PET) was performed on 10 patients with ischemic stroke and mild disability. The patients underwent cerebral angiography, x-ray computed tomography (CT) scan and regional cerebral measurements of CBF, CMRO2, oxygen extraction ratio (OER), and cerebral blood volume (CBV). Only minor arterial involvement was detected by angiography. In all patients, PET images of functional defects were more extensive than the corresponding CT hypodensity, and there were statistically significant reductions in CBF, CMRO2, and CBF/CBV ratio as compared with control subjects. Half of the regions analyzed in the affected hemisphere demonstrated a disruption of the normal coupling between CBF and CMRO2 as reflected by OER values significantly higher or lower than those of the corresponding region of the contralateral hemisphere. The pathophysiological pattern of high OER combined with a reduction in CBF proportionally greater than the reduction in CMRO2 was particularly indicative of regional chronic hemodynamic compromise in these patients

  12. {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in the management of adult multisystem Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Obert, Julie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Vercellino, Laetitia [Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); Van der Gucht, Axel [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); De Margerie-Mellon, Constance [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Radiologie, Hopital Saint-Louis, Paris (France); Bugnet, Emmanuelle; Lorillon, Gwenael [Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Chevret, Sylvie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Biostatistique et Information Medicale, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France); Tazi, Abdellatif [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France)

    2017-04-15

    The standard evaluation of multisystem Langerhans cell histiocytosis (LCH) includes a clinical evaluation, laboratory tests and a skeleton/skull X-ray survey, with chest high-resolution computed tomography (HRCT) in the case of pulmonary involvement. Preliminary reports suggest that {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG PET-CT) may be useful for evaluating patients with LCH. Fourteen consecutive adult patients with multisystem LCH were included in this retrospective study, and were evaluated using standard procedures and {sup 18}F-FDG PET-CT. The two sets of findings were compared both at baseline and during follow-up. Serial HRCT and pulmonary function tests were used to evaluate outcome in patients with lung involvement. At the baseline evaluation, PET-CT identified every LCH localization found with the standard evaluation (except a mild cecum infiltration). PET-CT showed additional lesions in seven patients, mostly involving bones, and differentiated inactive from active lesions. Thyroid {sup 18}F-FDG uptake was identified in three cases. No pituitary stalk {sup 18}F-FDG uptake was observed in patients with pituitary LCH. Only 3/12 (25 %) patients with pulmonary LCH displayed moderate pulmonary {sup 18}F-FDG uptake. During follow-up, variations (≥50 % of maximum standardized uptake) in bone {sup 18}F-FDG uptake intensity were correlated with disease state and response to treatment. The absence of lung {sup 18}F-FDG uptake did not preclude lung function improvement after treatment. Except for cases with pulmonary and pituitary involvement, {sup 18}F-FDG PET-CT could replace the standard evaluation for staging of adult patients with multisystem LCH. Serial PET-CT scans are useful for evaluating treatment responses, particularly in cases with bone LCH involvement. (orig.)

  13. Positron emission tomography. Present status and Romanian perspectives

    International Nuclear Information System (INIS)

    Constantinescu, B.; Lungu, V.

    1995-01-01

    Basic principles of the positron emission tomography (PET) are summarised. The main PET methods using short-lived radioisotopes (i.e. 11 C, 13 N, 15 O, 18 F) are briefly reviewed. Three types of particle accelerators for radioisotopes production and medical uses (including radiotherapy), corresponding to the proton energy (E p p p < 200 MeV) are presented. PET imaging equipment and procedures are discussed. Main radiopharmaceuticals based on beta decay for PET studies and their role in medicine is also described. Finally, perspectives for a PET program in Romania (Cyclotron + Radiochemistry + Tomograph ) are discussed. (author)

  14. Additional value of integrated PET-CT in the detection and characterization of lung metastases: correlation with CT alone and PET alone

    International Nuclear Information System (INIS)

    Wever, W. de; Meylaerts, L.; Verschakelen, J.A.; Ceuninck, L. de; Stroobants, S.

    2007-01-01

    The purpose was evaluating retrospectively the additional value of integrated positron emission tomography (PET) and computed tomography (CT) in the detection of pulmonary metastases in comparison with CT and PET alone. Fifty-six lung nodules, divided into three groups according their size, detected in 24 consecutive patients with a known primary tumor were retrospectively evaluated with integrated PET-CT, CT and PET. The nature of these nodules was determined by either histopathology or a follow-up of at least 6 months. The CT and PET images of the integrated PET-CT were evaluated separately by a radiologist and a nuclear medicine physician, the integrated PET-CT images were evaluated by a chest radiologist and nuclear medicine physician in consensus. The investigators were asked to search lung nodules and to determine whether these nodules were metastases or not. Sensitivity and accuracy for CT, PET and integrated PET-CT for characterization of all pulmonary nodules were, respectively: 100%, 90%, 100% and 57%, 55%, 55%. There was no significant difference in the characterization of pulmonary nodules between integrated PET-CT and CT alone (P=1.000) and PET alone (P=0.1306). An accurate evaluation is only possible for lesions larger than 1 cm. (orig.)

  15. Bone formation rather than inflammation reflects Ankylosing Spondylitis activity on PET-CT: a pilot study

    OpenAIRE

    Bruijnen, Stefan TG; van der Weijden, Mignon AC; Klein, Joannes P; Hoekstra, Otto S; Boellaard, Ronald; van Denderen, J Christiaan; Dijkmans, Ben AC; Voskuyl, Alexandre E; van der Horst-Bruinsma, Irene E; van der Laken, Conny J

    2012-01-01

    Introduction Positron Emission Tomography - Computer Tomography (PET-CT) is an interesting imaging technique to visualize Ankylosing Spondylitis (AS) activity using specific PET tracers. Previous studies have shown that the PET tracers [18F]FDG and [11C](R)PK11195 can target inflammation (synovitis) in rheumatoid arthritis (RA) and may therefore be useful in AS. Another interesting tracer for AS is [18F]Fluoride, which targets bone formation. In a pilot setting, the potential of PET-CT in ima...

  16. Combined positron emission tomography/computed tomography (PET/CT) for clinical oncology: technical aspects and acquisition protocols

    International Nuclear Information System (INIS)

    Beyer, T.

    2004-01-01

    Combined PET/CT imaging is a non-invasive means of reviewing both, the anatomy and the molecular pathways of a patient during a quasi-simultaneous examination. Since the introduction of the prototype PET/CT in 1998 a rapid development of this imaging technology is being witnessed. The incorporation of fast PET detector technology into PET/CT designs and the routine use of the CT transmission images for attenuation correction of the PET allow for anato-metabolic whole-body examinations to be completed in less than 30 min. Thus, PET/CT imaging offers a logistical advantage to both, the patient and the clinicians since the two complementary exams - whenever clinically indicated - can be performed almost at the same time and a single integrated report can be created. Nevertheless, a number of pit-falls, primarily from the use of CT-based attenuation correction, have been identified and are being addressed through optimized acquisition protocols. It is fair to say, that PET/CT has been integrated in the diagnostic imaging arena, and in many cases has led to a close collaboration between different, yet complementary diagnostic and therapeutic medical disciplines. (orig.)

  17. Sparse representation and dictionary learning penalized image reconstruction for positron emission tomography

    International Nuclear Information System (INIS)

    Chen, Shuhang; Liu, Huafeng; Shi, Pengcheng; Chen, Yunmei

    2015-01-01

    Accurate and robust reconstruction of the radioactivity concentration is of great importance in positron emission tomography (PET) imaging. Given the Poisson nature of photo-counting measurements, we present a reconstruction framework that integrates sparsity penalty on a dictionary into a maximum likelihood estimator. Patch-sparsity on a dictionary provides the regularization for our effort, and iterative procedures are used to solve the maximum likelihood function formulated on Poisson statistics. Specifically, in our formulation, a dictionary could be trained on CT images, to provide intrinsic anatomical structures for the reconstructed images, or adaptively learned from the noisy measurements of PET. Accuracy of the strategy with very promising application results from Monte-Carlo simulations, and real data are demonstrated. (paper)

  18. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hines, H.

    2001-01-01

    ADAC Laboratories has two main imaging strengths: PET and Gamma Cameras. PET's three-dimensional imaging of metabolic function is used in oncology, with emerging opportunties in cardiology, genetic mapping and pharmaceuticals research. In oncology, PET imaging can provide comprehensive and accurate staging information which is not available from CT or MRI. In some cases, this information can lead to modification of treatment, for example from an aggressive approach to one of palliation. The SKYLight is the world's first and only gantry-free camera. It is a dual-detector variable angle camera designed for high throughput, with unsurpassed openness and patient access. (orig.)

  19. Positron emission tomography in the diagnosis and staging of lung cancer

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Højgaard, L

    2001-01-01

    positron emission tomography (PET) and gamma-camera PET in the diagnostic investigation of non-small-cell lung cancer (NSCLC). A systematic literature search was carried out in the MEDLINE and EMBASE databases and the Cochrane Controlled Trials Register. We identified 55 original works on the diagnostic...

  20. Non-target activity detection by post-radioembolization yttrium-90 PET/CT: Image assessment technique and case examples

    Directory of Open Access Journals (Sweden)

    Yung Hsiang eKao

    2014-02-01

    Full Text Available High-resolution yttrium-90 (90Y imaging of post-radioembolization microsphere biodistribution may be achieved by conventional positron emission tomography with integrated computed tomography (PET/CT scanners that have time-of-flight capability. However, reconstructed 90Y PET/CT images have high background noise, making non-target activity detection technically challenging. This educational article describes our image assessment technique for non-target activity detection by 90Y PET/CT which qualitatively overcomes the problem of background noise. We present selected case examples of non-target activity in untargeted liver, stomach, gallbladder, chest wall and kidney, supported by angiography and 90Y bremsstrahlung single photon emission computed tomography with integrated computed tomography (SPECT/CT or technetium-99m macroaggregated albumin SPECT/CT.

  1. Intra-tumour 18F-FDG uptake heterogeneity decreases the reliability on target volume definition with positron emission tomography/computed tomography imaging

    International Nuclear Information System (INIS)

    Dong, Xinzhe; Wu, Peipei; Yu, Jinming; Xing, Ligang; Sun, Xiaorong; Li, Wenwu; Wan, Honglin

    2015-01-01

    This study aims to explore whether the intra-tumour 18 F-fluorodeoxyglucose (FDG) uptake heterogeneity affects the reliability of target volume definition with FDG positron emission tomography/computed tomography (PET/CT) imaging for nonsmall cell lung cancer (NSCLC) and squamous cell oesophageal cancer (SCEC). Patients with NSCLC (n = 50) or SCEC (n = 50) who received 18 F-FDG PET/CT scanning before treatments were included in this retrospective study. Intra-tumour FDG uptake heterogeneity was assessed by visual scoring, the coefficient of variation (COV) of the standardised uptake value (SUV) and the image texture feature (entropy). Tumour volumes (gross tumour volume (GTV) ) were delineated on the CT images (GTV CT ), the fused PET/CT images (GTV PET-CT ) and the PET images, using a threshold at 40% SUV max (GTV PET40% ) or the SUV cut-off value of 2.5 (GTV PET2.5 ). The correlation between the FDG uptake heterogeneity parameters and the differences in tumour volumes among GTV CT , GTV PET-CT , GTV PET40% and GTV PET2.5 was analysed. For both NSCLC and SCEC, obvious correlations were found between uptake heterogeneity, SUV or tumour volumes. Three types of heterogeneity parameters were consistent and closely related to each other. Substantial differences between the four methods of GTV definition were found. The differences between the GTV correlated significantly with PET heterogeneity defined with the visual score, the COV or the textural feature-entropy for NSCLC and SCEC. In tumours with a high FDG uptake heterogeneity, a larger GTV delineation difference was found. Advance image segmentation algorithms dealing with tracer uptake heterogeneity should be incorporated into the treatment planning system.

  2. Additional benefit of {sup 18}F-fluorodeoxyglucose integrated positron emission tomography/computed tomography in the staging of oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gillies, R.S. [Oxford Cancer and Haematology Centre, Churchill Hospital, Department of Medical Oncology, Oxford (United Kingdom); Oxford Cancer and Haematology Centre, Churchill Hospital, Department of Oesophagogastric Surgery, Oxford (United Kingdom); Middleton, M.R. [Oxford Cancer and Haematology Centre, Churchill Hospital, Department of Medical Oncology, Oxford (United Kingdom); Maynard, N.D. [Oxford Cancer and Haematology Centre, Churchill Hospital, Department of Oesophagogastric Surgery, Oxford (United Kingdom); Bradley, K.M.; Gleeson, F.V. [Oxford Cancer and Haematology Centre, Churchill Hospital, Department of Radiology, Oxford (United Kingdom)

    2011-02-15

    {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG PET) has been shown to improve the accuracy of staging in oesophageal cancer. We assessed the benefit of PET/CT over conventional staging and determined if tumour histology had any significant impact on PET/CT findings. A retrospective cohort study, reviewing the results from 200 consecutive patients considered suitable for radical treatment, undergoing routine PET/CT staging comparing the results from CT and endoscopic ultrasound, as well as multi-disciplinary team records. Adenocarcinoma and squamous cell carcinoma were compared for maximum Standardised Uptake Value (SUV{sub max}), involvement of local lymph nodes and distant metastases. PET/CT provided additional information in 37 patients (18.5%) and directly altered management in 34 (17%): 22 (11%) were upstaged; 15 (7.5%) were downstaged, 12 of whom (6%) received radical treatment. There were 11 false negatives (5.5%) and 1 false positive (0.5%). SUV{sub max} was significantly lower for adenocarcinoma than squamous cell carcinoma (median 9.1 versus 13.5, p = 0.003). Staging with PET/CT offers additional benefit over conventional imaging and should form part of routine staging for oesophageal cancer. Adenocarcinoma and squamous cell carcinoma display significantly different FDG-avidity. (orig.)

  3. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  4. Diagnosis of non-osseous spinal metastatic disease: the role of PET/CT and PET/MRI.

    Science.gov (United States)

    Batouli, Ali; Braun, John; Singh, Kamal; Gholamrezanezhad, Ali; Casagranda, Bethany U; Alavi, Abass

    2018-06-01

    The spine is the third most common site for distant metastasis in cancer patients with approximately 70% of patients with metastatic cancer having spinal involvement. Positron emission tomography (PET), combined with computed tomography (CT) or magnetic resonance imaging (MRI), has been deeply integrated in modern clinical oncology as a pivotal component of the diagnostic work-up of patients with cancer. PET is able to diagnose several neoplastic processes before any detectable morphological changes can be identified by anatomic imaging modalities alone. In this review, we discuss the role of PET/CT and PET/MRI in the diagnostic management of non-osseous metastatic disease of the spinal canal. While sometimes subtle, recognizing such disease on FDG PET/CT and PET/MRI imaging done routinely in cancer patients can guide treatment strategies to potentially prevent irreversible neurological damage.

  5. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  6. The application of positron emission tomography/computed tomography in radiation treatment planning: effect on gross target volume definition and treatment management.

    Science.gov (United States)

    Iğdem, S; Alço, G; Ercan, T; Unalan, B; Kara, B; Geceer, G; Akman, C; Zengin, F O; Atilla, S; Okkan, S

    2010-04-01

    To analyse the effect of the use of molecular imaging on gross target volume (GTV) definition and treatment management. Fifty patients with various solid tumours who underwent positron emission tomography (PET)/computed tomography (CT) simulation for radiotherapy planning from 2006 to 2008 were enrolled in this study. First, F-18 fluorodeoxyglucose (FDG)-PET and CT scans of the treatment site in the treatment position and then a whole body scan were carried out with a dedicated PET/CT scanner and fused thereafter. FDG-avid primary tumour and lymph nodes were included into the GTV. A multidisciplinary team defined the target volume, and contouring was carried out by a radiation oncologist using visual methods. To compare the PET/CT-based volumes with CT-based volumes, contours were drawn on CT-only data with the help of site-specific radiologists who were blind to the PET/CT results after a median time of 7 months. In general, our PET/CT volumes were larger than our CT-based volumes. This difference was significant in patients with head and neck cancers. Major changes (> or =25%) in GTV delineation were observed in 44% of patients. In 16% of cases, PET/CT detected incidental second primaries and metastatic disease, changing the treatment strategy from curative to palliative. Integrating functional imaging with FDG-PET/CT into the radiotherapy planning process resulted in major changes in a significant proportion of our patients. An interdisciplinary approach between imaging and radiation oncology departments is essential in defining the target volumes. Copyright 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Comparison of CE-FDG-PET/CT with CE-FDG-PET/MR in the evaluation of osseous metastases in breast cancer patients

    OpenAIRE

    Catalano, O A; Nicolai, E; Rosen, B R; Luongo, A; Catalano, M; Iannace, C; Guimaraes, A; Vangel, M G; Mahmood, U; Soricelli, A; Salvatore, M

    2015-01-01

    Background: Despite improvements in treatments, metastatic breast cancer remains difficult to cure. Bones constitute the most common site of first-time recurrence, occurring in 40?75% of cases. Therefore, evaluation for possible osseous metastases is crucial. Technetium 99 (99Tc) bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography (PET)-computed tomography (PET-CT) are the most commonly used techniques to assess osseous metastasis. PET magnetic resonance (PET-MR) ima...

  8. Is Image Registration of Fluorodeoxyglucose–Positron Emission Tomography/Computed Tomography for Head-and-Neck Cancer Treatment Planning Necessary?

    International Nuclear Information System (INIS)

    Fried, David; Lawrence, Michael; Khandani, Amir H.; Rosenman, Julian; Cullip, Tim; Chera, Bhishamjit S.

    2012-01-01

    Purpose: To evaluate dosimetry and patterns of failure related to fluorodeoxyglucose–positron emission tomography (FDG-PET)–defined biological tumor volumes (BTVs) for head-and-neck squamous cell carcinoma (HNSCC) treated with definitive radiotherapy (RT). Methods and Materials: We conducted a retrospective study of 91 HNSCC patients who received pretreatment PET/CT scans that were not formally used for target delineation. The median follow-up was 34.5 months. Image registration was performed for PET, planning CT, and post-RT failure CT scans. Previously defined primary (CT PRIMARY ) and nodal (CT NODE ) gross tumor volumes (GTV) were used. The primary BTV (BTV PRIMARY ) and nodal BTV (BTV NODE ) were defined visually (PET vis ). The BTV PRIMARY was also contoured using 40% and 50% peak PET activity (PET 40, PET 50 ). The recurrent GTVs were contoured on post-RT CT scans. Dosimetry was evaluated on the planning-CT and pretreatment PET scan. PET and CT dosimetric/volumetric data was compared for those with and without local-regional failure (LRF). Results: In all, 29 of 91 (32%) patients experienced LRF: 10 local alone, 7 regional alone, and 12 local and regional. BTVs and CT volumes had less than complete overlap. BTVs were smaller than CT-defined targets. Dosimetric coverage was similar between failed and controlled groups as well as between BTVs and CT-defined volumes. Conclusions: PET and CT-defined tumor volumes received similar RT doses despite having less than complete overlap and the inaccuracies of image registration. LRF correlated with both CT and PET-defined volumes. The dosimetry for PET- and/or CT-based tumor volumes was not significantly inferior in patients with LRF. CT-based delineation alone may be sufficient for treatment planning in patients with HNSCC. Image registration of FDG-PET may not be necessary.

  9. PET/CT and vascular disease: Current concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti Filho, Jose Leite Gondim; Souza Leao Lima, Ronaldo de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Souza Machado Neto, Luiz de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Kayat Bittencourt, Leonardo, E-mail: lkayat@terra.com.br [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Cortes Domingues, Romeu [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Fonseca, Lea Mirian Barbosa da [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil)

    2011-10-15

    Since its introduction in 2001, positron emission tomography associated to computed tomography (PET/CT) has been established as a standard tool in cancer evaluation. Being a multimodality imaging method, it combines in a single session the sensitivity granted by PET for detection of molecular targets within the picomolar range, with an underlying submilimetric resolution inherent to CT, that can precisely localize the PET findings. In this last decade, there have been new insights regarding the pathophysiology of atherosclerosis, particularly about plaque rupture and vascular remodeling. This has increased the interest for research on PET/CT in vascular diseases as a potential new diagnostic tool, since some PET molecular targets could identify diseases before the manifestation of gross anatomic features. In this review, we will describe the current applications of PET/CT in vascular diseases, emphasizing its usefulness in the settings of vasculitis, aneurysms, vascular graft infection, aortic dissection, and atherosclerosis/plaque vulnerability. Although not being properly peripheral vascular conditions, ischemic cardiovascular disease and cerebrovascular disease will be briefly addressed as well, due to their widespread prevalence and importance.

  10. FDG PET/CT in cancer

    DEFF Research Database (Denmark)

    Petersen, Henrik; Holdgaard, Paw Christian; Madsen, Poul Henning

    2016-01-01

    PURPOSE: The Region of Southern Denmark (RSD), covering 1.2 of Denmark's 5.6 million inhabitants, established a task force to (1) retrieve literature evidence for the clinical use of positron emission tomography (PET)/CT and provide consequent recommendations and further to (2) compare the actual...... use of PET/CT in the RSD with these recommendations. This article summarizes the results. METHODS: A Work Group appointed a professional Subgroup which made Clinician Groups conduct literature reviews on six selected cancers responsible for 5,768 (62.6 %) of 9,213 PET/CT scans in the RSD in 2012...... use of PET/CT and literature-based recommendations was high in the first five mentioned cancers in that 96.2 % of scans were made for grade A or B indications versus only 22.2 % in gynaecological cancers. CONCLUSION: Evidence-based usefulness was reported in five of six selected cancers; evidence...

  11. Positron Emission Tomography : background, possibilities and perspectives in neuroscience

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way. This includes the measurement of the pharmacokinetics of labeled drugs and the measurement of the effects of drugs and/or therapy on metabolism. Also deviations of

  12. Current applications and future developments of positron emission tomography in head and neck cancer

    International Nuclear Information System (INIS)

    Lonneux, M.

    2005-01-01

    Positron emission tomography (PET-scan) is a well-established imaging modality in oncology. Using FDG, PET has also a wide range of applications in head and neck tumors for diagnosis, staging, monitoring of response to therapy, and detection of relapse. After a short technical introduction, the current indications of PET-FDG in head and neck tumors are reviewed. Present and future developments of PET are twofold: the use of new tracers for protein synthesis, cellular proliferation or detection of hypoxia etc., and the introduction of metabolic imaging as a adjunct to CT and MRI to determine target-volumes in radiation treatment planning. However, it has to be emphasized that a thorough clinical validation of the methods used is mandatory before their implementation in routine practice. (author)

  13. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  14. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  15. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  16. PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin

    2018-02-01

    Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.

  17. Budget impact from the incorporation of positron emission tomography - computed tomography for staging lung cancers.

    Science.gov (United States)

    Biz, Aline Navega; Caetano, Rosângela

    2015-01-01

    To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer. The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease's prevalence and on the technologies' accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used. The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively. The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

  18. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  19. [PET/CT: protocol aspects and legal controversies].

    Science.gov (United States)

    Gorospe Sarasúa, L; Vicente Bártulos, A; González Gordaliza, C; García Poza, J; Lourido García, D; Jover Díaz, R

    2008-01-01

    The combination of positron emission tomography (PET) and computed tomography (CT) in a single scanner (PET/CT) allows anatomic and metabolic images to be fused and correlated with a high degree of accuracy; this represents a very important landmark in the history of medicine and especially in the area of diagnostic imaging. Nevertheless, the implementation, startup, and operation of a PET/CT scanner presents particularly interesting challenges, because it involves the integration of two well-established and consolidated techniques (CT and PET, which provide complementary information) that have traditionally been carried out in the context of two different specialties (radiology and nuclear medicine). The rapid diffusion of this new integrated technology raises a series of questions related to the optimal protocols for image acquisition, the supervision of the examinations, image interpretation, and reporting, as well as questions related to the legal competence and responsibility of the specialists involved in a PET/CT study. The objective of this article is to approach these aspects from a constructive perspective and to stimulate the dialog between the specialties of radiology and nuclear medicine, with the aim of maximizing the diagnostic potential of PET/CT and thus of providing better care for patients.

  20. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  1. [(18)F]Fluorodeoxyglucose - positron emission tomography/computed tomography improves staging in patients with high-risk muscle-invasive bladder cancer scheduled for radical cystectomy.

    Science.gov (United States)

    Kollberg, Petter; Almquist, Helen; Bläckberg, Mats; Cronberg, Carin; Garpered, Sabine; Gudjonsson, Sigurdur; Kleist, Jakob; Lyttkens, Kerstin; Patschan, Oliver; Liedberg, Fredrik

    2015-01-01

    The aim of this study was to evaluate the clinical use of [(18)F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) in addition to conventional preoperative radiological investigations in a defined group of patients with high-risk muscle-invasive bladder cancer. In total, 103 patients with high-risk muscle-invasive bladder cancer defined as stage T3/T4 disease or as stage T2 with hydronephrosis or high-risk histological features, who were provisionally scheduled to undergo cystectomy, were prospectively recruited to the study. The patients were referred to FDG-PET/CT in addition to standard preoperative investigation with computed tomography (CT). The final treatment decision was reached at a multidisciplinary conference based on all available information including the FDG-PET/CT findings. Compared to CT alone, FDG-PET/CT provided more supplemental findings suggesting malignant manifestations in 48 (47%) of the 103 patients. The additional FDG-PET/CT findings led to an altered provisional treatment plan in 28 out of 103 patients (27%), detection of disseminated bladder cancer and subsequent cancellation of the initially intended cystectomy in 16 patients, and identification of disseminated disease and treatment with induction chemotherapy before radical cystectomy in 12 patients. Preoperative FDG-PET/CT changed the treatment plan for a considerable proportion (27%) of the present patients. Accordingly, such examination can potentially improve the preoperative staging of cystectomy patients with high-risk features, and may also reduce the number of futile operations in patients with advanced disease who are beyond cure.

  2. Positron emission tomography-computed tomography protocol considerations for head and neck cancer imaging.

    Science.gov (United States)

    Escott, Edward J

    2008-08-01

    Positron emission tomographic-computed tomographic (PET-CT) imaging of patients with primary head and neck cancers has become an established approach for staging and restaging, as well as radiation therapy planning. The inherent co-registration of PET and CT images made possible by the integrated PET-CT scanner is particularly valuable in head and neck cancer imaging due to the complex and closely situated anatomy in this part of the body, the varied sources of physiologic and benign 2-deoxy-2-[F-18]fluoro-D-glucose (FDG) tracer uptake that occurs in the neck, and the varied and complex posttreatment appearance of the neck. Careful optimization of both the CT and the PET portion of the examination is essential to insure the most accurate and clinically valuable interpretation of these examinations.

  3. Seeing the Unseen—Bioturbation in 4D: Tracing Bioirrigation in Marine Sediment Using Positron Emission Tomography and Computed Tomography

    Science.gov (United States)

    Delefosse, Matthieu; Kristensen, Erik; Crunelle, Diane; Braad, Poul Erik; Dam, Johan Hygum; Thisgaard, Helge; Thomassen, Anders; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Understanding spatial and temporal patterns of bioirrigation induced by benthic fauna ventilation is critical given its significance on benthic nutrient exchange and biogeochemistry in coastal ecosystems. The quantification of this process challenges marine scientists because faunal activities and behaviors are concealed in an opaque sediment matrix. Here, we use a hybrid medical imaging technique, positron emission tomography and computed tomography (PET/CT) to provide a qualitative visual and fully quantitative description of bioirrigation in 4D (space and time). As a study case, we present images of porewater advection induced by the well-studied lugworm (Arenicola marina). Our results show that PET/CT allows more comprehensive studies on ventilation and bioirrigation than possible using techniques traditionally applied in marine ecology. We provide a dynamic three-dimensional description of bioirrigation by the lugworm at very high temporal and spatial resolution. Results obtained with the PET/CT are in agreement with literature data on lugworm ventilation and bioirrigation. Major advantages of PET/CT over methods commonly used are its non-invasive and non-destructive approach and its capacity to provide information that otherwise would require multiple methods. Furthermore, PET/CT scan is versatile as it can be used for a variety of benthic macrofauna species and sediment types and it provides information on burrow morphology or animal behavior. The lack of accessibility to the expensive equipment is its major drawback which can only be overcome through collaboration among several institutions. PMID:25837626

  4. Predicted extracapsular invasion of hilar lymph node metastasis by fusion positron emission tomography/computed tomography in patients with lung cancer.

    Science.gov (United States)

    Makino, Takashi; Hata, Yoshinobu; Otsuka, Hajime; Koezuka, Satoshi; Isobe, Kazutoshi; Tochigi, Nobumi; Shiraga, Nobuyuki; Shibuya, Kazutoshi; Homma, Sakae; Iyoda, Akira

    2015-09-01

    Intraoperative detection of hilar lymph node metastasis, particularly with extracapsular invasion, may affect the surgical procedure in patients with lung cancer, as the preoperative estimation of hilar lymph node metastasis is unsatisfactory. The aim of this study was to investigate whether fusion positron emission tomography/computed tomography (PET/CT) is able to predict extracapsular invasion of hilar lymph node metastasis. Between April, 2007 and April, 2013, 509 patients with primary lung cancer underwent surgical resection at our institution, among whom 28 patients exhibiting hilar lymph node metastasis (at stations 10 and 11) were enrolled in this study. A maximum lymph node standardized uptake value of >2.5 in PET scans was interpreted as positive. A total of 17 patients had positive preoperative PET/CT findings in their hilar lymph nodes, while the remaining 11 had negative findings. With regard to extracapsular nodal invasion, the PET/CT findings (P=0.0005) and the histological findings (squamous cell carcinoma, P=0.05) were found to be significant predictors in the univariate analysis. In the multivariate analysis, the PET/CT findings were the only independent predictor (P=0.0004). The requirement for extensive pulmonary resection (sleeve lobectomy, bilobectomy or pneumonectomy) was significantly more frequent in the patient group with positive compared with the group with negative PET/CT findings (76 vs. 9%, respectively, P=0.01). Therefore, the PET/CT findings in the hilar lymph nodes were useful for the prediction of extracapsular invasion and, consequently, for the estimation of possible extensive pulmonary resection.

  5. Positron emission tomography and migraine. Tomographie par emission de positons et migraine

    Energy Technology Data Exchange (ETDEWEB)

    Chabriat, H. (CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot)

    1992-04-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT{sub 2} serotonin receptors can be studied in migraine patients with PET.

  6. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both...

  7. Cancer screening using 18F-FDG PET/CT in Korean asymptomatic volunteers. A preliminary report

    International Nuclear Information System (INIS)

    Lee, Jeong-Won; Kang, Keon-Wook; Paeng, Jin-Chul; Lee, Sang-Mi; Jang, Su-Jin; Chung, June-Key; Lee, Myung-Chul; Lee, Dong-Soo

    2009-01-01

    This study was performed to evaluate the clinical value of 18 F-fluorodeoxyglucose (FDG) positron-emission tomography (PET)/computed tomography (CT) for cancer screening in Korean asymptomatic people. Between February 2004 and December 2006, 1,587 asymptomatic individuals underwent FDG PET/CT as part of a cancer screening program with some other diagnostic tests at the healthcare center of our hospital. After excluding patients with a history of malignant tumor, 1,336 subjects were enrolled. All PET/CT images were visually analyzed. In subjects showing positive findings for PET/CT or other screening tests, further diagnostic tests and pathological confirmation were performed. Of the 1,336 subjects, malignant tumors were found in 16 participants (1.2%, thyroid cancer: 9, lung cancer: 2, stomach cancer: 2, and others: 4). There were 47 cases (3.6%) of positive PET/CT findings- 11 cases were true positive (thyroid cancer: 8, lung cancer: 1, renal cancer: 1, and invasive thymoma), and 36 false positive, and five cases were false negative. The overall detection rate of PET/CT was 0.8%, and the sensitivity, specificity, positive-predictive value, and negative-predictive value of PET/CT were 68.8, 97.2, 23.4, and 99.6%, respectively. Fluorodeoxyglucose positron-emission tomography has the potential to detect various kinds of malignant tumors in cancer screening test, and the overall detection rate of PET/CT was 0.8%. FDG PET/CT can be a useful cancer screening modality with the selection of high-risk group and appropriate combination with other screening modalities. (author)

  8. Positron emission CT on post-traumatic epilepsy

    International Nuclear Information System (INIS)

    Tsukiyama, Takashi; Tsubokawa, Takashi; Doi, Nobuyasu; Sato, Kohten; Iio, Masaaki.

    1983-01-01

    Six patients suffering from post-traumatic epilepsy were checked by encephalography (EEG), X-ray CT and cerebral positron emission computed tomography (PECT) using 11 C-carbon dioxide ( 11 CO 2 ) and 11 C-glucoses as indicators of the local cerebral circulation and local cerebral glucose utilization, in order to assess the diagnostic value of PECT in post-traumatic epilepsy. In those patients (4 cases) who had focal electrical abnormalities or X-ray CT lesions, PECT clearly revealed localized regions of decreased cerebral circulation and glucose utilization. A focal hypometabolic zone also appeared in the post-traumatic epilepsy (1 case) which had a normal X-ray CT. One case, who had been treated for several years by medication but showed no EEG change and no abnormality on X-ray CT, revealed a normal circulation and metabolism by RECT. This case did not require any further medication for epilepsy. It is concluded that positron emission CT represents a useful diagnostic method for post-traumatic epilepsy which does not demonstrate any abnormality on X-ray CT. (author)

  9. F-18 fluoride positron emission tomography/computed tomography in the diagnosis of avascular necrosis of the femoral head: Comparison with magnetic resonance imaging

    Science.gov (United States)

    Gayana, Shankaramurthy; Bhattacharya, Anish; Sen, Ramesh Kumar; Singh, Paramjeet; Prakash, Mahesh; Mittal, Bhagwant Rai

    2016-01-01

    Objective: Femoral head avascular necrosis (FHAVN) is one of the increasingly common causes of musculoskeletal disability and poses a major diagnostic and therapeutic challenge. Although radiography, scintigraphy, computed tomography (CT), and magnetic resonance imaging (MRI) have been widely used in the diagnosis of FHAVN, positron emission tomography (PET) has recently been evaluated to assess vascularity of the femoral head. In this study, the authors compared F-18 fluoride PET/CT with MRI in the initial diagnosis of FHAVN. Patients and Methods: We prospectively studied 51 consecutive patients with a high clinical suspicion of FHAVN. All patients underwent MRI and F-18 fluoride PET/CT, the time interval between the two scans being 4–10 (mean 8) days. Two nuclear medicine physicians blinded to the MRI report read the PET/CT scans. Clinical assessment was also done. Final diagnoses were made by surgical pathology or clinical and radiologic follow-up. Results: A final diagnosis of avascular necrosis (AVN) was made in 40 patients. MRI was 96.5% sensitive, 100% specific, and 98.03% accurate while PET/CT was 100% sensitive, specific, and accurate in diagnosing FHAVN. The agreement between the two imaging modalities for the diagnosis of AVN was 96.07%. Conclusion: F-18 fluoride PET/CT showed good agreement with MRI in the initial diagnosis of FHAVN and can be better than MRI in detecting early disease. PMID:26917886

  10. F-18 fluoride positron emission tomography/computed tomography in the diagnosis of avascular necrosis of the femoral head: Comparison with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Gayana, Shankaramurthy; Bhattacharya, Anish; Sen, Ramesh Kumar; Singh, Paramjeet; Prakash, Mahesh; Mittal, Bhagwant Rai

    2016-01-01

    Femoral head avascular necrosis (FHAVN) is one of the increasingly common causes of musculoskeletal disability and poses a major diagnostic and therapeutic challenge. Although radiography, scintigraphy, computed tomography (CT), and magnetic resonance imaging (MRI) have been widely used in the diagnosis of FHAVN, positron emission tomography (PET) has recently been evaluated to assess vascularity of the femoral head. In this study, the authors compared F-18 fluoride PET/CT with MRI in the initial diagnosis of FHAVN. We prospectively studied 51 consecutive patients with a high clinical suspicion of FHAVN. All patients underwent MRI and F-18 fluoride PET/CT, the time interval between the two scans being 4–10 (mean 8) days. Two nuclear medicine physicians blinded to the MRI report read the PET/CT scans. Clinical assessment was also done. Final diagnoses were made by surgical pathology or clinical and radiologic follow-up. A final diagnosis of avascular necrosis (AVN) was made in 40 patients. MRI was 96.5% sensitive, 100% specific, and 98.03% accurate while PET/CT was 100% sensitive, specific, and accurate in diagnosing FHAVN. The agreement between the two imaging modalities for the diagnosis of AVN was 96.07%. F-18 fluoride PET/CT showed good agreement with MRI in the initial diagnosis of FHAVN and can be better than MRI in detecting early disease

  11. Interstitial brachytherapy for liver metastases and assessment of response by positron emission tomography: a case report

    Directory of Open Access Journals (Sweden)

    Goura Kishor Rath

    2010-10-01

    Full Text Available For liver metastases (LM, image guided percutaneous ablative procedures such as radiofrequency ablation (RFA, laser induced thermal therapy (LITT and trans-arterial chemo-embolisation (TACE are increasingly being used because they are relatively safer, less invasive and equally effective. CT scan guided interstitial brachytherapy (IBT with a single large dose of radiation by high dose rate (HDR brachytherapy is a novel technique of treating LM and has shown good results. Positron emission tomography (PET scan may provide better information for assessing the response toIBT procedures. We hereby report a case of LM that was treated by HDR IBT and PET scan was done in addition to CT scan for assessing the response.

  12. Chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) with massive vertebral bone erosion: computed tomography (CT), magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) findings.

    Science.gov (United States)

    Nakano, Sachiko; Okauchi, Kenzo; Tsushima, Yoshito

    2014-02-01

    A 62-year-old male presented with sudden onset of low back and right leg pain. Contrast-enhanced computed tomography demonstrated an abdominal aortic aneurysm (AAA), along with a large mass lesion causing vertebral body erosion. Magnetic resonance imaging (MRI) suggested that the mass lesion consisted of a chronic hematoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) demonstrated increased uptake around the mass lesion, but not around the AAA. Surgical intervention was performed, and the subsequent histological diagnosis was chronic contained rupture of AAA. The mass lesion consisted of chronic hematoma and necrosis with inflammatory cell infiltration and hemosiderin deposition. This condition mimics some neoplastic diseases, but MRI and FDG-PET findings may help establish the correct diagnosis.

  13. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  14. FDG PET/CT in oncology: 'raising the bar'

    Energy Technology Data Exchange (ETDEWEB)

    Patel, C.N. [Departments of Radiology and Nuclear Medicine, Churchill Hospital, Oxford Radcliffe NHS Trust, Oxford (United Kingdom); Goldstone, A.R.; Chowdhury, F.U. [Departments of Radiology and Nuclear Medicine, St James' s University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Scarsbrook, A.F., E-mail: andrew.scarsbrook@leedsth.nhs.u [Departments of Radiology and Nuclear Medicine, St James' s University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom)

    2010-07-15

    Integrated positron-emission tomography/computed tomography (PET/CT) with 2-[{sup 18}F]-fluoro-2-deoxy-D-glucose (FDG) has revolutionized oncological imaging in recent years and now has a firmly established role in a variety of tumour types. There have been simultaneous step-wise advances in scanner technology, which are yet to be exploited to their full potential in clinical practice. This article will review these technological developments and explore how refinements in imaging protocols can further improve the accuracy and efficacy of PET/CT in oncology. The promises, and limitations, of emerging oncological applications of FDG PET/CT in radiotherapy planning and therapy response assessment will be explored. Potential future developments, including the use of FDG PET probes in oncological surgery, advanced data analysis techniques, and the prospect of integrated PET/magnetic resonance imaging (PET/MRI) will be highlighted.

  15. 18F-FLT Positron Emission Tomography/Computed Tomography Imaging in Pancreatic Cancer: Determination of Tumor Proliferative Activity and Comparison with Glycolytic Activity as Measured by 18F-FDG Positron Emission Tomography/Computed Tomography Imaging

    Directory of Open Access Journals (Sweden)

    Senait Aknaw Debebe

    2016-02-01

    Full Text Available Objective: This phase-I imaging study examined the imaging characteristic of 3’-deoxy-3’-(18F-fluorothymidine (18F-FLT positron emission tomography (PET in patients with pancreatic cancer and comparisons were made with (18F-fluorodeoxyglucose (18F-FDG. The ultimate aim was to develop a molecular imaging tool that could better define the biologic characteristics of pancreas cancer, and to identify the patients who could potentially benefit from surgical resection who were deemed inoperable by conventional means of staging. Methods: Six patients with newly diagnosed pancreatic cancer underwent a combined FLT and FDG computed tomography (CT PET/CT imaging protocol. The FLT PET/CT scan was performed within 1 week of FDG PET/CT imaging. Tumor uptake of a tracer was determined and compared using various techniques; statistical thresholding (z score=2.5, and fixed standardized uptake value (SUV thresholds of 1.4 and 2.5, and applying a threshold of 40% of maximum SUV (SUVmax and mean SUV (SUVmean. The correlation of functional tumor volumes (FTV between 18F-FDG and 18F-FLT was assessed using linear regression analysis. Results: It was found that there is a correlation in FTV due to metabolic and proliferation activity when using a threshold of SUV 2.5 for FDG and 1.4 for FLT (r=0.698, p=ns, but a better correlation was obtained when using SUV of 2.5 for both tracers (r=0.698, p=ns. The z score thresholding (z=2.5 method showed lower correlation between the FTVs (r=0.698, p=ns of FDG and FLT PET. Conclusion: Different tumor segmentation techniques yielded varying degrees of correlation in FTV between FLT and FDGPET images. FLT imaging may have a different meaning in determining tumor biology and prognosis.

  16. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  17. (18)F-FDG positron-emission tomography/computed tomography findings of radiographic lesions suggesting old healed tuberculosis.

    Science.gov (United States)

    Jeong, Yun-Jeong; Paeng, Jin Chul; Nam, Hyun-Yeol; Lee, Ji Sun; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon

    2014-03-01

    The presence of radiographic lesions suggesting old healed tuberculosis (TB) is one of the strongest risk factors for the subsequent development of active TB. We elucidated the metabolic activity of radiographic lesions suggesting old healed TB using (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT). This cross-sectional study included 63 participants with radiographic lesions suggesting old healed TB and with available (18)F-FDG PET/CT scans. The maximum standardized uptake value (SUVmax) measured in the lesions, the clinical characteristics, results of the tuberculin skin test (TST) and interferon-γ release assay (IGRA) were analyzed. The SUVmax in old healed TB was 1.5 or higher among nine (14.3%) participants. Age (adjusted odds ratio [aOR], 1.23; 95% CI, 1.03-1.46), history of previous TB (aOR, 60.43; 95% CI, 1.71-2131.65), and extent of the lesions (aOR, 1.34; 95% CI, 1.02-1.75) were associated with higher SUVmax. The positive rates for the TST and IGRA were not different between groups with and without increased FDG uptake. Increased FDG uptake on (18)F-FDG PET/CT was observed in a subset of patients with radiographic lesions suggesting old healed TB. Given that the factors associated with increased FDG uptake are known risk factors for TB development, the possibility exists that participants with old healed TB lesions with higher SUV on (18)F-FDG PET/CT scans might be at higher risk for active TB.

  18. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Tokuda, Yoshiyuki; Oshima, Hideki; Araki, Yoshimori; Narita, Yuji; Mutsuga, Masato; Kato, Katsuhiko; Usui, Akihiko

    2013-06-01

    To investigate the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting thoracic aortic prosthetic graft infection. Nine patients with clinically suspected thoracic aortic graft infection underwent FDG-PET/CT scanning. In these patients, the diagnoses could not be confirmed using conventional modalities. The patients' clinical courses were retrospectively reviewed. On the basis of surgical, microbiological and clinical follow-up findings, the aortic grafts were considered infected in 4 patients and not infected in 5. All 4 patients with graft infection (root: 2 cases, arch: 1 case and descending: 1 case) eventually underwent in situ re-replacement. Two of the 4 patients also had abdominal grafts; however, only the thoracic grafts were replaced because uptake was low around the abdominal grafts. The maximal standardized uptake value (SUVmax) in the perigraft area was higher in the infected group than in the non-infected group (11.4 ± 4.5 vs 6.9 ± 6.4), although the difference was not statistically significant. According to the receiver operating characteristic analysis, SUVmax >8 appeared to be the cut-off value in distinguishing the two groups (sensitivity: 1.0 and specificity: 0.8). FDG-PET/CT is useful for confirming the presence of graft infection by detecting high uptake around grafts and excluding other causes of inflammation. An SUVmax value greater than 8 around a graft suggests the presence of graft infection. In addition, FDG-PET/CT can be used to clarify the precise extent of infection. This is especially useful if multiple separated prosthetic grafts have been implanted.

  19. Intra-tumour 18F-FDG uptake heterogeneity decreases the reliability on target volume definition with positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Dong, Xinzhe; Wu, Peipei; Sun, Xiaorong; Li, Wenwu; Wan, Honglin; Yu, Jinming; Xing, Ligang

    2015-06-01

    This study aims to explore whether the intra-tumour (18) F-fluorodeoxyglucose (FDG) uptake heterogeneity affects the reliability of target volume definition with FDG positron emission tomography/computed tomography (PET/CT) imaging for nonsmall cell lung cancer (NSCLC) and squamous cell oesophageal cancer (SCEC). Patients with NSCLC (n = 50) or SCEC (n = 50) who received (18)F-FDG PET/CT scanning before treatments were included in this retrospective study. Intra-tumour FDG uptake heterogeneity was assessed by visual scoring, the coefficient of variation (COV) of the standardised uptake value (SUV) and the image texture feature (entropy). Tumour volumes (gross tumour volume (GTV)) were delineated on the CT images (GTV(CT)), the fused PET/CT images (GTV(PET-CT)) and the PET images, using a threshold at 40% SUV(max) (GTV(PET40%)) or the SUV cut-off value of 2.5 (GTV(PET2.5)). The correlation between the FDG uptake heterogeneity parameters and the differences in tumour volumes among GTV(CT), GTV(PET-CT), GTV(PET40%) and GTV(PET2.5) was analysed. For both NSCLC and SCEC, obvious correlations were found between uptake heterogeneity, SUV or tumour volumes. Three types of heterogeneity parameters were consistent and closely related to each other. Substantial differences between the four methods of GTV definition were found. The differences between the GTV correlated significantly with PET heterogeneity defined with the visual score, the COV or the textural feature-entropy for NSCLC and SCEC. In tumours with a high FDG uptake heterogeneity, a larger GTV delineation difference was found. Advance image segmentation algorithms dealing with tracer uptake heterogeneity should be incorporated into the treatment planning system. © 2015 The Royal Australian and New Zealand College of Radiologists.

  20. Transconvolution and the virtual positron emission tomograph—A new method for cross calibration in quantitative PET/CT imaging

    International Nuclear Information System (INIS)

    Prenosil, George A.; Weitzel, Thilo; Hentschel, Michael; Klaeser, Bernd; Krause, Thomas

    2013-01-01

    Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating 68 Ge/ 68 Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a

  1. Cardiological applications of positron emission tomography

    International Nuclear Information System (INIS)

    Schelbert, H.; Czernin, J.

    1994-01-01

    Positron emission tomography (PET) expands the diagnostic possibilities of nuclear medicine techniques for the diagnosis of coronary artery disease and, especially, for the identification of myocardial viability. The presence of coronary artery disease can be detected by evaluation of myocardial blood flow at rest and during pharmacologically induced hyperemia with a sensitivity of 84 to 98% and a specificity of 78 to 100% according to recent studies. Comparative investigations in the same patients have demonstrated a significant gain in the diagnostic accuracy of PET as compared with single photon emission computed tomography (SPECT). PET has influenced even more profoundly the identification of myocardial viability. Measured against the functional outcome of regional contractile function after successful revascularization, an increase of glucose utilization relative to regional myocardial blood flow is 77 to 85% accurate in identifying reversibly injured myocardium. Conversely, PET is 78 to 92% accurate in identifying myocardium as irreversibly injured when pre-operative glucose uptake was reduced or absent. Recent studies have indicated that it is possible to predict to some extent post-revascularization improvement in left ventricular function as well as in congestive heart failure related symptoms in patients with ischemic cardiomyopathy. Furthermore, PET can identify patients with an increased risk of mortality and morbidity as a result of ischemic heart disease and, thus, stratify patients to the most appropriate and cost-effective therapeutic approach. (authors)

  2. Diagnostic accuracy of 18F-FDG-PET and PET/CT in patients with Ewing sarcoma family tumours: a systematic review and a meta-analysis

    International Nuclear Information System (INIS)

    Treglia, Giorgio; Salsano, Marco; Stefanelli, Antonella; Mattoli, Maria Vittoria; Giordano, Alessandro; Bonomo, Lorenzo

    2012-01-01

    To systematically review and meta-analyse literature data on the diagnostic performance of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) in patients with Ewing sarcoma family tumours (ESFT). PubMed/MEDLINE, Embase and Scopus databases were searched for articles that evaluated FDG-PET and PET/CT in patients with ESFT from inception to 31 May 2011. Studies that fulfilled the three following criteria were included in the systematic review: FDG-PET or PET/CT performed in patients with ESFT; articles about the diagnostic accuracy of FDG-PET and PET/CT; sample size of at least 10 patients with ESFT were included. Studies in which there were sufficient data to reassess sensitivity and specificity of FDG-PET or PET/CT in ESFT were included in the meta-analysis, excluding duplicate publications. Finally, pooled sensitivity, pooled specificity and area under the receiver operating characteristic (ROC) curve of FDG-PET or PET/CT in ESFT were calculated. We found 13 studies comprising a total of 342 patients with ESFT. The main findings of the studies included are presented. The meta-analysis of five selected studies provided these results about FDG-PET and PET/CT in ESFT: pooled sensitivity: 96% (95% confidence interval [CI] 91-99%); pooled specificity: 92% (95% CI 87-96%); area under the ROC curve: 0.97. With regard to the staging and restaging of patients with ESFT, the sensitivity, specificity and accuracy of FDG-PET and PET/CT are high; the combination of FDG-PET or PET/CT with conventional imaging is a valuable tool for the staging and restaging of ESFT and has a relevant impact on the treatment strategy plan. (orig.)

  3. Prospective Study of 68Ga-DOTATATE Positron Emission Tomography/Computed Tomography for Detecting Gastro-Entero-Pancreatic Neuroendocrine Tumors and Unknown Primary Sites.

    Science.gov (United States)

    Sadowski, Samira M; Neychev, Vladimir; Millo, Corina; Shih, Joanna; Nilubol, Naris; Herscovitch, Peter; Pacak, Karel; Marx, Stephen J; Kebebew, Electron

    2016-02-20

    Gastro-entero-pancreatic neuroendocrine tumors (GEPNETs) are increasing in incidence, and accurate staging is important for selecting the appropriate treatment. (68)Ga-DOTATATE imaging is a promising approach for detecting GEPNETs and could help in selecting optimal therapeutic strategies. The aim of this study was to prospectively determine the clinical utility of (68)Ga-DOTATATE positron emission tomography (PET)/computed tomography (CT) in detecting unknown primary and metastatic GEPNETs. One hundred thirty-one patients were enrolled in a prospective study of patients undergoing (68)Ga-DOTATATE PET/CT, (111)In-pentetreotide single-photon emission computed tomography (SPECT)/CT and multiphasic CT scan, and/or magnetic resonance imaging in a blinded fashion with comprehensive biochemical testing. The primary outcome measure was the detection of lesions by each imaging study. (68)Ga-DOTATATE PET/CT imaging detected 95.1% of lesions (95% CI, 92.4% to 96.8%) with an average maximum standardized uptake value of 65.4 ± 47 (range, 6.9 to 244), anatomic imaging detected 45.3% of lesions (95% CI, 37.9% to 52.9%), and (111)In-pentetreotide SPECT/CT detected 30.9% of lesions (95% CI, 25.0% to 37.5%), with a significant difference between imaging modalities (P < .001). In four of 14 patients (28.6%), (68)Ga-DOTATATE PET/CT found a previously unknown primary tumor, and detected primary GEPNET, lymph node, and distant metastases correctly in 72 of 113 lesions (63.7%) when compared with histopathology, with 22.1% and 38.9% detected by using (111)In-pentetreotide SPECT/CT and anatomic imaging, respectively. On the basis of findings with (68)Ga-DOTATATE PET/CT, 43 of 131 patients (32.8%) had a change in management recommendation. In patients with carcinoid symptoms but negative biochemical testing, (68)Ga-DOTATATE PET/CT detected lesions in 65.2% of patients, 40% of which were detected neither by anatomic imaging nor by (111)In-pentetreotide SPECT/CT. (68)Ga-DOTATATE PET/CT

  4. Utility of positron emission tomography for tumour surveillance in children with neurofibromatosis type 1

    Energy Technology Data Exchange (ETDEWEB)

    Moharir, Mahendranath [Hospital for Sick Children, Division of Neurology, Ontario (Canada); London, Kevin [Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney (Australia); Howman-Giles, Robert [University of Sydney, Discipline of Imaging, Faculty of Medicine, Sydney (Australia); North, Kathryn [Children' s Hospital at Westmead, Institute for Neuroscience and Muscle Research, Sydney, NSW (Australia)

    2010-07-15

    There is little consensus regarding optimal surveillance of optic pathway glioma (OPG) and plexiform neurofibroma (PNF) in childhood neurofibromatosis type 1 (NF1). {sup 18}F-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography and computed tomography (PET/CT) is employed in the surveillance of adult PNFs; but its utility has neither been specifically studied in children with PNFs nor in children with OPG. Review of PET/CT studies was performed in NF1 children with OPG or PNF. FDG-avidity of tumours was semi-quantitatively analysed and graded by calculating the maximum standardised uptake value (SUV{sub max}) [grade 1: <3 (low), grade 2: >3-<4 (intermediate), grade 3: >4 (intense)]. Eighteen children (ten girls; median age: 8.5-years) had PET/CT. Nineteen OPGs were imaged. The SUV{sub max} could be measured in 16. Ten were grade 1 and three each were grade 2 and grade 3. FDG-avidity reduced from grade 3 to grade 1 in two symptomatic OPGs following chemotherapy and this was associated with clinical improvement. PET/CT diagnosed symptomatic OPGs with a sensitivity of 0.625 [95% confidence interval (CI): 0.259-0.897] and specificity of 0.875 (95% CI: 0.466-0.993). Sixteen PNFs were imaged. Twelve were grade 1 and two each were grade 2 and grade 3. The two grade 3 PNFs were confirmed malignant peripheral nerve sheath tumours. PET/CT diagnosed malignant transformation with a sensitivity of 1.0 (95% CI: 0.197-1.0) and specificity of 0.857 (95% CI: 0.561-0.974). PET/CT may contribute useful information to the surveillance of OPG in childhood NF1 - particularly to identify progressive, symptomatic tumours. As in adults, PET/CT is useful for the detection of malignant transformation in PNFs in children with NF1. (orig.)

  5. Utility of positron emission tomography for tumour surveillance in children with neurofibromatosis type 1

    International Nuclear Information System (INIS)

    Moharir, Mahendranath; London, Kevin; Howman-Giles, Robert; North, Kathryn

    2010-01-01

    There is little consensus regarding optimal surveillance of optic pathway glioma (OPG) and plexiform neurofibroma (PNF) in childhood neurofibromatosis type 1 (NF1). 18 F-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography and computed tomography (PET/CT) is employed in the surveillance of adult PNFs; but its utility has neither been specifically studied in children with PNFs nor in children with OPG. Review of PET/CT studies was performed in NF1 children with OPG or PNF. FDG-avidity of tumours was semi-quantitatively analysed and graded by calculating the maximum standardised uptake value (SUV max ) [grade 1: 3- 4 (intense)]. Eighteen children (ten girls; median age: 8.5-years) had PET/CT. Nineteen OPGs were imaged. The SUV max could be measured in 16. Ten were grade 1 and three each were grade 2 and grade 3. FDG-avidity reduced from grade 3 to grade 1 in two symptomatic OPGs following chemotherapy and this was associated with clinical improvement. PET/CT diagnosed symptomatic OPGs with a sensitivity of 0.625 [95% confidence interval (CI): 0.259-0.897] and specificity of 0.875 (95% CI: 0.466-0.993). Sixteen PNFs were imaged. Twelve were grade 1 and two each were grade 2 and grade 3. The two grade 3 PNFs were confirmed malignant peripheral nerve sheath tumours. PET/CT diagnosed malignant transformation with a sensitivity of 1.0 (95% CI: 0.197-1.0) and specificity of 0.857 (95% CI: 0.561-0.974). PET/CT may contribute useful information to the surveillance of OPG in childhood NF1 - particularly to identify progressive, symptomatic tumours. As in adults, PET/CT is useful for the detection of malignant transformation in PNFs in children with NF1. (orig.)

  6. The role of 18F-FDG PET/CT in pediatric lymph-node acute lymphoblastic leukemia involvement.

    Science.gov (United States)

    Cistaro, Angelina; Saglio, Francesco; Asaftei, Sebastian; Fania, Piercarlo; Berger, Massimo; Fagioli, Franca

    2011-01-01

    In pediatric oncology, positron emission tomography/computed tomography (PET/CT) is emerging as an essential diagnostic tool in characterizing suspicious neoplastic lesions and staging malignant diseases. Most studies regarding the possible role of FDG-PET/CT in the management of acute lymphoblastic leukemia (ALL) patients are limited to adults. Here we report a pediatric patient with recurrent ALL, in which FDG-PET/CT was used both to define more precisely the cause of lymphadenopathy and to assess the effect of the second-line therapy.

  7. Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

    International Nuclear Information System (INIS)

    Walker, Gary V.; Niikura, Naoki; Yang Wei; Rohren, Eric; Valero, Vicente; Woodward, Wendy A.; Alvarez, Ricardo H.; Lucci, Anthony; Ueno, Naoto T.; Buchholz, Thomas A.

    2012-01-01

    Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes

  8. Enhancement of positron emission tomography-computed tomography image quality using the principle of stochastic resonance

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Sharma, Punit; Singh, Harmandeep; Patel, Chetan; Sarkar, Kaushik; Kumar, Rakesh; Bal, Chandra Sekhar

    2014-01-01

    Acquisition of higher counts improves visual perception of positron emission tomography-computed tomography (PET-CT) image. Larger radiopharmaceutical doses (implies more radiation dose) are administered to acquire this count in a short time period. However, diagnostic information does not increase after a certain threshold of counts. This study was conducted to develop a post processing method based on principle of “stochastic resonance” to improve visual perception of the PET-CT image having a required threshold counts. PET-CT images (JPEG file format) with low, medium, and high counts in the image were included in this study. The image was corrupted with the addition of Poisson noise. The amplitude of the Poisson noise was adjusted by dividing each pixel by a constant 1, 2, 4, 8, 16, and 32. The best amplitude of the noise that gave best images quality was selected based on high value of entropy of the output image, high value of structural similarity index and feature similarity index. Visual perception of the image was evaluated by two nuclear medicine physicians. The variation in structural and feature similarity of the image was not appreciable visually, but statistically images deteriorated as the noise amplitude increases although maintaining structural (above 70%) and feature (above 80%) similarity of input images in all cases. We obtained the best image quality at noise amplitude “4” in which 88% structural and 95% feature similarity of the input images was retained. This method of stochastic resonance can be used to improve the visual perception of the PET-CT image. This can indirectly lead to reduction of radiation dose

  9. Budget impact from the incorporation of positron emission tomography – computed tomography for staging lung cancers

    Directory of Open Access Journals (Sweden)

    Aline Navega Biz

    2015-01-01

    Full Text Available OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used.RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD million for the restricted offer and 202.7 BRL (125.9 USD million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD and 600 BRL (372.8 USD million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD and 103.8 BRL (64.5 USD million, considering PET-CT for negative CT and PET-CT for all, respectively.CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

  10. The economic impact of 18FDG positron emission tomography in the surgical management of colorectal cancer with hepatic metastases.

    Science.gov (United States)

    Zubeldia, Jose M; Bednarczyk, Edward M; Baker, John G; Nabi, Hani A

    2005-08-01

    (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is recognized as a powerful tool in the management of patients with recurrent and/or metastatic colorectal cancer. The aim of this was was to analyze costs from the payer's perspective, of adding FDG-PET to a computed tomography (CT) scan preoperatively in colorectal cancer patients with resectable hepatic metastases. CT with and without FDG-PET were compared among patients with colorectal cancer in staging for surgical resection of hepatic metastases. Outcomes included uncomplicated surgery, complicated surgery, or death. Extrahepatic disease occurrence rates and diagnostic accuracy of CT and FDG-PET were obtained from published sources. Complication rates and costs for CT, FDG-PET, and surgical procedures were obtained from Healthcare Finance Administration data. The average expected surgical cost per patient when FDG-PET was used to determine the presence of extrahepatic disease was 16,278 dollars compared to 21,547 dollars for conventional management-a net savings of 5,269 dollars. Integration of FDG-PET into the presurgical evaluation of patients with hepatic metastases could substantially reduce overall costs and patients' morbidity. This substantial net saving results from the unique ability of FDG-PET in excluding patients with extrahepatic disease, and avoiding unnecessary surgical expenses.

  11. Clinical applications of positron emission tomography in breast cancer patients

    International Nuclear Information System (INIS)

    Roemer, W.; Avril, N.; Schwaiger, M.

    1997-01-01

    Increased glucose metabolism by malignant tissue can be visualized with positron emission tomography (PET), using the radiolabeled glucose analogue F-18 fluorodeoxyglucose (FDG). Depending on the criteria of image interpretation FDG-PET allows detection of breast cancer with a sensitivity of 68% to 94 % and a specificity of 84 % to 97 %. However, sensitivity to visualize small tumors (< 1 cm) is limited. Positron emission tomography demonstrates tumor involvement of regional lymph nodes with high accuracy, predominantly in patients with advanced breast cancer. The sensitivity for the detection of axillary lymph node metastases was 79% with a corresponding specificity of 96 %. Lymph node metastases could not be identified in four of six patients with small primary breast cancer (stage pT1), resulting in a sensitivity of only 33% in these patients. By visualizing primary tumors and metastases in one imaging procedure, PET imaging may allow the effective staging of breast cancer patients. Further studies are needed to define the role of scintigraphic techniques for the diagnostic work-up in patients. (author)

  12. Lesson of the month 1: Large vessel vasculitis - a diagnostic challenge and the role of 18-fluorodeoxyglucose positron emission tomography.

    Science.gov (United States)

    Allard, Andrew; Mootoo, Ramesh

    2017-07-01

    Large vessel vasculitis can pose a significant diagnostic challenge. It may be insidious in onset with the only presenting symptoms consisting of constitutional compromise. It may mimic other pathologies and the only serological abnormalities may be abnormal inflammatory markers. Conventional imaging modalities may not be diagnostic. We present a case of large vessel vasculitis that proved a significant diagnostic challenge with diagnosis established on 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) computerised tomography (CT) imaging. This is one of five cases of large vessel vasculitis that were diagnosed in the rheumatology department at our trust over a 12-month period with diagnosis established with the use of 18F-FDG PET CT. We discuss the advantages of 18F-FDG PET CT over more conventional imaging modalities in diagnosing large vessel vasculitis. © Royal College of Physicians 2017. All rights reserved.

  13. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography; Positronenemissionstomographie bei malignen Tumoren im Kopf- und Halsbereich. Beurteilung der diagnostischen Wertigkeit der Positronenemissionstomographie im Vergleich zur Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kettler, Nele

    2011-12-02

    , primarily by providing confirmation of the absence of metastases. To place the size and site of a malignant growth computed tomography will still be necessary in future. The positron emission tomography should not replace computed tomography for the diagnosis of malignant tumors at head and neck, but shows some utility where used in conjunction. The new technology, PET-CT, has since been used in routine examinations, and shows promise of better performance.

  14. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  15. PET-CT findings in patients with polymyalgia rheumatica without symptoms of cranial ischaemia

    DEFF Research Database (Denmark)

    Lund-Petersen, Alexander; Voss, Anne; Laustrup, Helle

    2017-01-01

    Introduction: Polymyalgia rheumatica (PMR) is an inflammatory disorder that affects the lderly. At present, evidence is limited regarding the usefulness of positron emission tomography-computed tomography (PET-CT) in the diagnosis of PMR. This study aimed to compare patient characteristics...... and symptoms with PET-CT findings in a Danish population of PMR patients without clinical symptoms of giant cell arteritis. Methods: The medical records of 50 Danish PET-CT-scanned patients with PMR were reviewed. Symptoms, characteristics and PET-CT findings were registered from the medical records. Results...... of the following three locations: the shoulder, the hip and the spinous processes. Vascular FDG uptake was seen in 7% of the patients. No significant correlations between any symptoms and any PET-CT findings were found. C-reactive protein was significantly lower in patients receiving glucocorticoids...

  16. Characterization of hepatic tumors using [11C]metomidate through positron emission tomography

    DEFF Research Database (Denmark)

    Roivainen, Anne; Naum, Alexandru; Nuutinen, Heikki

    2013-01-01

    ABSTRACT: BACKGROUND: Using positron emission tomography (PET), we compared two tracers, [11C]metomidate ([11C]MTO) and [11C]acetate ([11C]ACE), for the characterization of hepatic tumors. METHODS: Thirty-three patients underwent PET with [11C]MTO and [11C]ACE and magnetic resonance imaging (MRI...

  17. FDG PET/CT detects benign neurofibromas presenting as nodal masses: Imaging hallmarks of a diagnostic “red herring”

    International Nuclear Information System (INIS)

    Puranik, Ameya D.; Purandare, Nilendu C.; Bal, Munita M.; Agrawal, Archi; Shah, Sneha; Rangarajan, Venkatesh

    2015-01-01

    Multi-modality positron emission tomography/computed tomography (PET/CT) with 18F-fluoro-deoxy-glucose (FDG) depicts the enhancement pattern and metabolic intensity of lesions. Benign lesions with multiplicity, like neurofibromas often mimic similar appearing malignant neoplasms. We, report, a similar case where FDG PET/CT shows imaging hallmarks for diagnosing benign neurofibromas, in a patient with clinical presentation of lymphoma

  18. Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism

    International Nuclear Information System (INIS)

    Booij, J.; Tissingh, G.; Winogrodzka, A.; Royen, E.A. van

    1999-01-01

    Parkinsonism is a feature of a number of neurodegenerative diseases, including Parkinson's disease, multiple system atrophy and progressive supranuclear palsy. The results of post-mortem studies point to dysfunction of the dopaminergic neurotransmitter system in patients with parkinsonism. Nowadays, by using single-photon emission tomography (SPET) and positron emission tomography (PET) it is possible to visualise both the nigrostriatal dopaminergic neurons and the striatal dopamine D 2 receptors in vivo. Consequently, SPET and PET imaging of elements of the dopaminergic system can play an important role in the diagnosis of several parkinsonian syndromes. This review concentrates on findings of SPET and PET studies of the dopaminergic neurotransmitter system in various parkinsonian syndromes. (orig.)

  19. Diagnostic accuracy of {sup 18}F-FDG-PET and PET/CT in patients with Ewing sarcoma family tumours: a systematic review and a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Treglia, Giorgio [Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy); Institute of Nuclear Medicine, Positron Emission Tomography Centre, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy); Salsano, Marco; Stefanelli, Antonella; Mattoli, Maria Vittoria; Giordano, Alessandro [Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy); Bonomo, Lorenzo [Institute of Radiology, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy)

    2012-03-15

    To systematically review and meta-analyse literature data on the diagnostic performance of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) in patients with Ewing sarcoma family tumours (ESFT). PubMed/MEDLINE, Embase and Scopus databases were searched for articles that evaluated FDG-PET and PET/CT in patients with ESFT from inception to 31 May 2011. Studies that fulfilled the three following criteria were included in the systematic review: FDG-PET or PET/CT performed in patients with ESFT; articles about the diagnostic accuracy of FDG-PET and PET/CT; sample size of at least 10 patients with ESFT were included. Studies in which there were sufficient data to reassess sensitivity and specificity of FDG-PET or PET/CT in ESFT were included in the meta-analysis, excluding duplicate publications. Finally, pooled sensitivity, pooled specificity and area under the receiver operating characteristic (ROC) curve of FDG-PET or PET/CT in ESFT were calculated. We found 13 studies comprising a total of 342 patients with ESFT. The main findings of the studies included are presented. The meta-analysis of five selected studies provided these results about FDG-PET and PET/CT in ESFT: pooled sensitivity: 96% (95% confidence interval [CI] 91-99%); pooled specificity: 92% (95% CI 87-96%); area under the ROC curve: 0.97. With regard to the staging and restaging of patients with ESFT, the sensitivity, specificity and accuracy of FDG-PET and PET/CT are high; the combination of FDG-PET or PET/CT with conventional imaging is a valuable tool for the staging and restaging of ESFT and has a relevant impact on the treatment strategy plan. (orig.)

  20. Cardiac positron tomography

    International Nuclear Information System (INIS)

    Geltmann, E.M.; Roberts, R.; Sobel, B.E.

    1980-01-01

    Positron emission tomography (PET) performed after the administration of the positron-emitting radionuclides carbon-11 ( 11 C), nitrogen-13 ( 13 N), oxygen-15 ( 15 O) and fluorine-18 ( 18 F) has permitted the improved noninvasive assessment of the regional myocardial metabolism of normal physiologic substrates and intermediates and their cogeners. In experimental animals, the rate of oxidation of 11 C-palmitate correlates closely with other indexes of oxygen consumption, and the extraction of 11 C-palmitate (like that of 18 F-fatty acids and 18 F-fluoredoxyglucose) ist markedly diminished in regions of myocardial ischemia. In both experimental animals and in patients, myocardial infarct site and size, determined by positron emission tomography after the intravenous injection of 11 C-palmitate, correlate closely with the electrocardiographic infarct locus and enzymatically estimated infarct size as well as with the location and extent of regional left ventricular wall motion abnormalities. PET offers promise for assessment of flow as well despite the complexities involved. PET with 13 NH 3 appears to provide one useful qualitative index, although this tracer ist actively metabolized. Because of the quantitative capabilities of positron emission tomography and the rapid progress which is being made in the development of fast scan, multi-slice, and gated instrumentation, this technique is likely to facilitate improved understanding and characterization of regional myocardial metabolism and blood flow in man under physiological and pathophysiological conditions. (orig.) [de

  1. 3D fast reconstruction in positron emission tomography

    International Nuclear Information System (INIS)

    Egger, M.L.; Scheurer, A. Hermann; Joseph, C.; Morel, C.

    1996-01-01

    The issue of long reconstruction times in positron emission tomography (PET) has been addressed from several points of view, resulting in an affordable dedicated system capable of handling routine 3D reconstructions in a few minutes per frame : on the hardware side using fast processors and a parallel architecture, and on the software side, using efficient implementation of computationally less intensive algorithms

  2. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    International Nuclear Information System (INIS)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been

    2012-01-01

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  4. Lower maximum standardized uptake value of fluorine-18 fluorodeoxyglucose positron emission tomography coupled with computed tomography imaging in pancreatic ductal adenocarcinoma patients with diabetes.

    Science.gov (United States)

    Chung, Kwang Hyun; Park, Joo Kyung; Lee, Sang Hyub; Hwang, Dae Wook; Cho, Jai Young; Yoon, Yoo-Seok; Han, Ho-Seong; Hwang, Jin-Hyeok

    2015-04-01

    The effects of diabetes mellitus (DM) on sensitivity of fluorine-18 fluorodeoxyglucose positron emission tomography coupled with computed tomography ((18)F-FDG PET/CT) for diagnosing pancreatic ductal adenocarcinomas (PDACs) is not well known. This study was aimed to evaluate the effects of DM on the validity of (18)F-FDG PET/CT in PDAC. A total of 173 patients with PDACs who underwent (18)F-FDG PET/CT were enrolled (75 in the DM group and 98 in the non-DM group). The maximum standardized uptake values (SUVsmax) were compared. The mean SUVmax was significantly lower in the DM group than in the non-DM group (4.403 vs 5.998, P = .001). The sensitivity of SUVmax (cut-off value 4.0) was significantly lower in the DM group than in the non-DM group (49.3% vs 75.5%, P < .001) and also lower in normoglycemic DM patients (n = 24) than in non-DM patients (54.2% vs 75.5%, P = .038). DM contributes to a lower SUVmax of (18)F-FDG PET/CT in patients with PDACs. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Role and interpretation of fluorodeoxyglucose-positron emission tomography/computed tomography in HIV-infected patients with fever of unknown origin: a prospective study.

    Science.gov (United States)

    Martin, C; Castaigne, C; Tondeur, M; Flamen, P; De Wit, S

    2013-09-01

    The aim of the study was to evaluate prospectively the usefulness of fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) in investigation of fever of unknown origin (FUO) in HIV-positive patients and to determine whether HIV viraemia impacts on FDG-PET/CT performance. The FDG-PET/CT results of 20 HIV-infected patients with FUO were analysed and compared with the FDG-PET/CT results of 10 HIV-infected viraemic patients without FUO. The performance of FDG-PET/CT for identifying the aetiology of FUO was assessed. Final diagnosis for FUO was based on histopathology, microbiological assays, or clinical and imaging follow-up. FDG-PET/CT contributed to the diagnosis or exclusion of a focal aetiology of the febrile state in 80% of patients with FUO. The presence of increased FDG uptake in the central lymph node has 100% specificity for focal aetiology of fever, even in viraemic patients. The absence of hypermetabolic central lymph nodes in FUO patients has 100% negative predictive value for focal disease. Lymph node biopsy in central hypermetabolic areas allowed, in 100% of cases, identification of underlying disease in patients with FUO. Biopsy of peripheral lymph nodes should be performed in lymph nodes with maximum standardized uptake value (SUVmax) ≥ 6-8 (sensitivity 62.5%; specificity 75%) and avoided in lymph nodes with SUVmax = 0-4 (specificity 0%). High HIV viraemia does not prevent correct interpretation of FDG-PET/CT. As in HIV-negative patients, we confirm the usefulness of FDG-PET/CT in investigation of FUO in HIV-positive patients even if they are viraemic. © 2013 British HIV Association.

  6. 18F-FDG PET and PET/CT in Burkitt's lymphoma

    International Nuclear Information System (INIS)

    Karantanis, Dimitrios; Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P.; Georgiou, Evangelos; Johnston, Patrick B.; Wiseman, Gregory A.

    2010-01-01

    Objective: To explore the value of 18 F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  7. The Positron Emission Tomography. A diagnostic technique

    International Nuclear Information System (INIS)

    Salvadori, P.

    2001-01-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding [it

  8. Orbital flourine-18-fluorodeoxyglucose positron emission tomography in patients with Graves' disease for evaluation of active inflammation.

    Science.gov (United States)

    Uslu-Beşli, Lebriz; Kabasakal, Levent; Sağer, Sait; Cicik, Erdoğan; Asa, Sertaç; Sönmezoğlu, Kerim

    2017-11-01

    Prediction and early diagnosis of orbitopathy is needed in patients with Graves' disease, especially when radioiodine therapy is planned. Positron emission tomography/computerized tomography (PET/CT) using flourine-18-fluorodeoxyglucose (FDG) is an effective imaging modality in detection of inflammation, however, its ability to detect orbital inflammation has not been well studied. The aim of our study is to determine the ability of FDG PET/CT to detect orbital inflammation related with Graves' disease, identify active orbitopathy, predict the radioiodine-triggered orbitopathy, and find out the effects of radioiodine on orbital inflammation. Total 31 Graves' disease patients and 17 controls were included. All Graves' disease patients underwent cranial FDG PET/CT imaging prior therapy. Radioiodine therapy and post-treatment PET/CT study was applied to 21 patients. PET/CT images of all examinees were evaluated, measuring extraocular muscle maximum standard uptake value (SUVmax) and muscle thickness. FDG uptake was increased in the majority of extraocular muscles in Graves' disease patients in comparison to controls and this increase was found to be irrelevant from muscle thickness. Extraocular muscle SUVmax values did not increase in Graves' orbitopathy patients who received radioiodine under corticosteroid prophylaxis. SUVmax level of all orbital rectus muscles were increased after radioiodine therapy in nonsmokers, whereas no increase was detected in smokers. FDG PET/CT may be helpful in detection of extraocular muscle inflammation and it may show ongoing orbitopathy in early stages of inflammation before anatomical changes occur.

  9. What is the difference in the hybrid imaging techniques - SPECT/CT and PET-CT and is there any advantage of their application?

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2012-01-01

    The hybrid imaging methods - Single Photon Emission Tomography-Computer Tomography /SPECT-CT / and Positron Emission Tomography-Computer Tomography / PET-CT/ allow receiving of combined image of two different techniques. In such a way it is possible to superimpose detailed anatomical image of the multislice spiral computer tomography with specific and sensitive molecular images of the SPECT and PET in a single study, allowing utilization of the full possibilities of the both techniques. They have advantages and disadvantages, which basically stem from the differences in the used radiopharmaceuticals and their physical properties. In PET- CT - positron emitters are applied, most often 18F and 11C, while in SPECT-CT - single photon emitters, most often 99m Tc and 131 I. A disadvantage of PET is a high cost, which is produced in cyclotron and its logistics is complicated. The great advantage of PET is its better spatial resolution, compared to SPECT, because of the possibility for simultaneous detection of pared photons and better registration. These techniques, especially PET-CT are nowadays the most increasing imaging methods in the world in making diagnosis, staging and following the effect of treatment in patients with oncological, neurological, cardiological, orthopedic diseases and infections. Recently, they are applied for the purposes of radiotherapy planning on the basis of the metabolically active tumor. As a final result, compared to the conventional techniques - roentgenography, CT and MRI, it is possible in many cases to make an early and more precise diagnosis, saving patients' time and using most appropriate treatment. As a conclusion it is clear, that the hybrid imaging has future and its application will increase. (author)

  10. Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications

    International Nuclear Information System (INIS)

    Pagani, M.; Stone-Elander, S.; Larsson, S.A.

    1997-01-01

    The increasing amount of clinically relevant information obtained by positron emission tomography (PET), primarily with fluorine-18 labelled 2-deoxy-2-fluoro-d-glucose, has generated a demand for new routes for the widespread and cost-efficient use of positron-emitting radiopharmaceuticals. New dual-head single-photon emission tomography (SPET) cameras are being developed which offer coincidence detection with camera heads lacking a collimator or SPET imaging with specially designed collimators and additional photon shielding. Thus, not only satellite PET imaging units but also nuclear medicine units investing in these new SPET/PET systems need to examine all available alternatives for rational radionuclide supplies from host cyclotrons. This article examines 25 ''alternative'' positron-emitting radionuclides, discusses the impact of their decay properties on image quality and reviews methods for their production as well as for their application in imaging techniques. (orig.)

  11. Chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) with massive vertebral bone erosion. Computed tomography (CT), magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) findings

    International Nuclear Information System (INIS)

    Nakano, Sachiko; Okauchi, Kenzo; Tsushima, Yoshito

    2014-01-01

    A 62-year-old male presented with sudden onset of low back and right leg pain. Contrast-enhanced computed tomography demonstrated an abdominal aortic aneurysm (AAA), along with a large mass lesion causing vertebral body erosion. Magnetic resonance imaging (MRI) suggested that the mass lesion consisted of a chronic hematoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) demonstrated increased uptake around the mass lesion, but not around the AAA. Surgical intervention was performed, and the subsequent histological diagnosis was chronic contained rupture of AAA. The mass lesion consisted of chronic hematoma and necrosis with inflammatory cell infiltration and hemosiderin deposition. This condition mimics some neoplastic diseases, but MRI and FDG-PET findings may help establish the correct diagnosis. (author)

  12. 18F-fluorodeoxyglucose positron emission tomography-positive sarcoidosis after chemoradiotherapy for Hodgkin’s disease: a case report

    Directory of Open Access Journals (Sweden)

    Pham Alan

    2011-06-01

    Full Text Available Abstract Introduction The occurrence of granulomatous disease in the setting of Hodgkin's disease is rare; however, when it occurs it can pose significant clinical and diagnostic challenges for physicians treating these patients. Case presentation We report the case of a 33-year-old Caucasian woman of Mediterranean descent with newly diagnosed 18F-fluorodeoxyglucose (18F-FDG positron emission tomography (PET/computed tomography (CT scan-positive, early-stage Hodgkin's disease involving the cervical nodes who, despite having an excellent clinical response to chemotherapy, had a persistent 18F-FDG PET scan-positive study, which was suggestive of residual or progressive disease. A subsequent biopsy of her post-chemotherapy PET-positive nodes demonstrated sarcoidosis with no evidence of Hodgkin's disease. Conclusion This case highlights the fact that abnormalities observed on posttherapy PET/CT scans in patients with Hodgkin's disease are not always due to residual or progressive disease. An association between Hodgkin's disease and/or its treatment with an increased incidence of granulomatous disease appears to exist. Certain patterns of 18F-FDG uptake observed on PET/CT scans may suggest other pathologies, such as granulomatous inflammation, and because of the significant differences in prognosis and management, clinicians should maintain a low threshold of confidence for basing their diagnosis on histopathological evaluations when PET/CT results appear to be incongruent with the patient's clinical response.

  13. 18F-fluorodeoxyglucose positron emission tomography predicts survival of patients with neuroendocrine tumors

    DEFF Research Database (Denmark)

    Binderup, Tina; Knigge, Ulrich; Loft, Annika

    2010-01-01

    PURPOSE: (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is currently not used on a routine basis for imaging of neuroendocrine (NE) tumors. The aim of this study was to investigate the prognostic value of FDG-PET in patients with NE tumors. EXPERIMENTAL DESIGN: Ninety...

  14. The value of FDG positron emission tomography/computerised tomography (PET/CT) in pre-operative staging of colorectal cancer: a systematic review and economic evaluation.

    Science.gov (United States)

    Brush, J; Boyd, K; Chappell, F; Crawford, F; Dozier, M; Fenwick, E; Glanville, J; McIntosh, H; Renehan, A; Weller, D; Dunlop, M

    2011-09-01

    In the UK, colorectal cancer (CRC) is the third most common malignancy (behind lung and breast cancer) with 37,514 cases registered in 2006: around two-thirds (23,384) in the colon and one-third (14,130) in the rectum. Treatment of cancers of the colon can vary considerably, but surgical resection is the mainstay of treatment for curative intent. Following surgical resection, there is a comprehensive assessment of the tumour, it's invasion characteristics and spread (tumour staging). A number of imaging modalities are used in the pre-operative staging of CRCs including; computerised tomography (CT), magnetic resonance imaging, ultrasound imaging and positron emission tomography (PET). This report examines the role of CT in combination with PET scanning (PET/CT 'hybrid' scan). The research objectives are: to evaluate the diagnostic accuracy and therapeutic impact of fluorine-18-deoxyglucose (FDG) PET/CT for the pre-operative staging of primary, recurrent and metastatic cancer using systematic review methods; undertake probabilistic decision-analytic modelling (using Monte Carlo simulation); and conduct a value of information analysis to help inform whether or not there is potential worth in undertaking further research. For each aspect of the research - the systematic review, the handsearch study and the economic evaluation - a database was assembled from a comprehensive search for published and unpublished studies, which included database searches, reference lists search and contact with experts. In the systematic review prospective and retrospective patient series (diagnostic cohort) and randomised controlled trials (RCTs) were eligible for inclusion. Both consecutive series and series that are not explicitly reported as consecutive were included. Two reviewers extracted all data and applied the criteria independently and resolved disagreements by discussion. Data to populate 2 × 2 contingency tables consisting of the number of true positives, true negatives

  15. Preoperative staging of lung cancer with PET/CT: cost-effectiveness evaluation alongside a randomized controlled trial

    DEFF Research Database (Denmark)

    Søgaard, Rikke; Fischer, Barbara Malene B; Mortensen, Jann

    2011-01-01

    PURPOSE: Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost-effective......PURPOSE: Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost......-effectiveness. The objective of this study was to assess the cost-effectiveness of PET/CT as an adjunct to conventional workup for preoperative staging of NSCLC. METHODS: The study was conducted alongside an RCT in which 189 patients were allocated to conventional staging (n = 91) or conventional staging + PET/CT (n = 98......) and followed for 1 year after which the numbers of futile thoracotomies in each group were monitored. A full health care sector perspective was adapted for costing resource use. The outcome parameter was defined as the number needed to treat (NNT)-here number of PET/CT scans needed-to avoid one futile...

  16. Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton Therapy

    International Nuclear Information System (INIS)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A.; Michaud, Susan; Loeffler, Jay S.; DeLaney, Thomas F.; Liebsch, Norbert J.; Munzenrider, John E.; Fischman, Alan J.; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    Purpose: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. Methods and Materials: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3 GyE and 10 GyE (for an ocular melanoma) per fraction were delivered in 1 or 2 fields. Imaging was performed with a commercial PET/CT scanner for 30 min, starting within 20 min after treatment. The same treatment immobilization device was used during imaging for all but 2 patients. Measured PET/CT images were coregistered to the planning CT and compared with the corresponding PET expectation, obtained from CT-based Monte Carlo calculations complemented by functional information. For the ocular case, treatment position was approximately replicated, and spatial correlation was deduced from reference clips visible in both the planning radiographs and imaging CT. Here, the expected PET image was obtained from an analytical model. Results: Good spatial correlation and quantitative agreement within 30% were found between the measured and expected activity. For head-and-neck patients, the beam range could be verified with an accuracy of 1-2 mm in well-coregistered bony structures. Low spine and eye sites indicated the need for better fixation and coregistration methods. An analysis of activity decay revealed as tissue-effective half-lives of 800-1,150 s. Conclusions: This study demonstrates the feasibility of postradiation PET/CT for in vivo treatment verification. It also indicates some technological and methodological improvements needed for optimal clinical application

  17. PET-CT: current applications and new developments in the thorax.

    Science.gov (United States)

    Erasmus, Jeremy J; Mawlawi, Osama; Howard, Brandon; Patz, Edward F

    2014-02-01

    Positron emission tomography computed tomography(PET-CT) imaging has emerged as an essential clinical diagnostic tool in the evaluation of thoracic abnormalities. Currently, its primary role is for tumor imaging; it helps to differentiate benign from malignant nodules, stage tumors, determine response, and follow patients after therapy is complete. It has also been used for nononcologic diseases, but the indications are less well defined. PET is a fundamental component of the molecular imaging initiative, and as new more specific imaging probes and better instrumentation are developed, PET-CT is certain to improve diagnostic accuracy and become even more integrated into the imaging armamentarium. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Performance of FDG PET/CT in the clinical management of breast cancer.

    Science.gov (United States)

    Groheux, David; Espié, Marc; Giacchetti, Sylvie; Hindié, Elif

    2013-02-01

    In this analysis, the role of metabolic imaging with fluorine 18 fluorodeoxyglucose (FDG) in breast cancer is reviewed. The analysis was limited to recent works by using state-of-the-art positron emission tomography (PET)/computed tomography (CT) technology. The strengths and limitations of FDG PET/CT are examined in various clinical settings, and the following questions are answered: Is FDG PET/CT useful to differentiate malignant from benign breast lesions? Can FDG PET/CT replace sentinel node biopsy for axillary staging? What is the role of FDG PET/CT in initial staging of inflammatory or locally advanced breast cancer? What is the role of FDG PET/CT in initial staging of clinical stage IIA and IIB and primary operable stage IIIA breast cancer? How does FDG PET/CT compare with conventional techniques in the restaging of cancer in patients who are suspected of having disease recurrence? What is the role of FDG PET/CT in the assessment of early response to neoadjuvant therapy and of response to therapy for metastatic disease? Some recommendations for clinical practice are given.

  20. Investigating Serotonergic Function Using Positron Emission Tomography: Overview and Recent Findings

    NARCIS (Netherlands)

    Veltman, D.J.; Ruhe, H.G.; Booij, J.

    2010-01-01

    Mono-aminergic neurotransmitters, in particular serotonin (5-HT), are involved in regulating a large number of psychological and physiological functions, and abnormal 5-HT transmission has been implicated in a wide variety of neuropsychiatric disorders. Positron emission tomography (PET) is a

  1. Role of 18F fluorodeoxyglucose positron emission tomography/computed tomography in the detection of recurrence in patients with cervical cancer

    International Nuclear Information System (INIS)

    Bhoil, Amit; Mittal, Bhagwant Rai; Bhattacharya, Anish; Santhosh, Sampath; Patel, Firuza

    2013-01-01

    Treatment of cervical cancer is usually surgery in the early stages and radiotherapy or chemoradiotherapy in more advanced stages of the disease. Recurrence may occur in multiple sites following primary treatment. Although recurrent metastatic disease is not curable, surgical treatment may be of great help if locoregional recurrence is detected early. Fluorine-18 Fluorodeoxyglucose positron emission tomography - computed tomography ( 18 F FDG PET/CT) forms an important part of investigations in the diagnosis of clinically suspicious recurrent cervical cancer. To assess the role of 18 F FDG PET/CT in diagnosing recurrence in patients with clinical suspicion of recurrent cervical cancer. We retrospectively evaluated 53 histopathologically proved patients of cervical cancer. All the patients had been treated with either surgery/radiation therapy with or without chemotherapy. The standard PET/CT acquisition protocol, with delayed post void static pelvic images, wherever required, was followed in all patients. Significant uptake of FDG in the lymph nodes was considered to be a recurrence suggestive of metastasis. Para-aortic lymph nodal involvement was considered to be distant metastasis. Any significant uptake in the lung nodule on FDG PET was evaluated either by histological confirmation, by taking fine needle aspiration cytology (FNAC), or by a follow-up chest CT done after three months. Of the 53 patients with clinically equivocal recurrence, FDG PET/CT suggested recurrence in 41 patients (local recurrence in 14 patients and distant recurrence/metastasis with or without local recurrence in 27 patients). It had a sensitivity of 97.5%, a specificity of 63.6%, positive predictive value of 90.9%, and negative predictive value of 87.5%. PET/CT appears to have an important role in detecting recurrence following primary treatment of cervical cancer. The high positive and negative predictive values of PET/CT may be helpful in planning management of recurrent cervical cancer

  2. Biological imaging in radiation therapy: role of positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nestle, Ursula; Hentschel, Michael; Grosu, Anca-Ligia [Departments of Radiation Oncology, University of Freiburg, Robert Koch Str. 3, 79106 Freiburg (Germany); Weber, Wolfgang [Nuclear Medicine, University of Freiburg, Robert Koch Str. 3, 79106 Freiburg (Germany)], E-mail: ursula.nestle@uniklinik-freiburg.de

    2009-01-07

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required. (topical review)

  3. Biological imaging in radiation therapy: role of positron emission tomography.

    Science.gov (United States)

    Nestle, Ursula; Weber, Wolfgang; Hentschel, Michael; Grosu, Anca-Ligia

    2009-01-07

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required.

  4. 18F-fluorodeoxyglucose positron emission tomography in colorectal cancer: value in primary staging and follow-up

    International Nuclear Information System (INIS)

    Joerg, L.; Heinisch, M.; Rechberger, E.; Kurz, F.; Klug, R.; Aufschnaiter, M; Hammer, J.; Langsteger, W.

    2002-01-01

    Positron emission tomography using 18 F-fluorodeoxyglucose (FDG-PET) is a encouraging imaging techniques allowing a highly sensitive whole-body search for malignant foci detected by their increased glucose metabolism compared with benign tissues. Several studies are now available that indicate its added value for diagnosis and staging of colorectal cancer. In all, patient management seems to be changed in 20-30 % of patients who undergo fluorodeoxyglucose positron emission tomography in addition to standard staging procedures. Fluorodeoxyglucose positron emission tomography is also useful in monitoring radiation therapy and chemotherapy. Regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  5. Clinical applications of positron emission tomography at Montreal Neurological Institute

    International Nuclear Information System (INIS)

    Morgan, P.P.

    1983-01-01

    The Montreal Neurological Institute occupies a leading position in positron emission tomography (PET) of the brain with the help of the following three techological gains: they have acquired a 'Therascan' positron emission tomograph manufactured by Atomic Energy of Canada Ltd.; also, a 'Baby Cyclotron' manufactured by Japan Steel Works Ltd.; and they have written a computer program to display the results in colour. Four short-lived isotopes are used; 11 C, 15 O, 18 F, 13 N. Studies of the oxygen uptake of tumours, their glucose metabolism (as monitored by 18 F labelled 2-fluoro-2-deoxyglucose), and their uptake of therapeutic agents, provide valuable research and diagnostic information. PET is also being used to study epilepsy and cerebrovascular disease

  6. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo

    2016-01-01

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value

  7. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value.

  8. MRI and {sup 18}F-fluorodeoxyglucose positron emission tomography in hemimegalencephaly

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, K.T.; Liebig, T.; Hosten, N. [Departments of Radiology and Nuclear Medicine, Virchow-Klinikum, Charite, Berlin (Germany); Amthauer, H.; Farahati, J.; Felix, R. [Departments of Radiology and Nuclear Medicine, Virchow-Klinikum, Charite, Berlin (Germany); PET-Centre Berlin, Virchow-Klinikum, Charite, Humboldt-University, Berlin (Germany); Etou, A.; Lehmann, T.N. [Department of Neurosurgery, Virchow-Klinikum, Charite, Humboldt-University, Berlin (Germany)

    2000-10-01

    We report hemimegalencephaly in a 44-year-old woman with mental retardation, epilepsy and a mild hemiparesis. In addition to typical findings on MRI, 2-deoxy-2[{sup 18}F]fluorodeoxyglucose positron-emission tomography (PET) demonstrated glucose hypometabolism of the affected hemisphere. The results of PET have been coregistered with morphological information from the MRI studies by image fusion. (orig.)

  9. Detection of occult bone metastases of lung cancer with Fluorine-18 fluorodeoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Foo, S.S.; Ramdave, S.; Berlangieri, S.U.; Scott, A.M.

    2004-01-01

    Accurate staging of cancer has a critical role in optimal patient management. Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) is superior to CT in the detection of local and distant metastasesin patients with non-small cell lung cancer. Although Tc-99 m methylene diphosphonate (MDP) bone scanning is well established in the evaluation of bone metastases, there are conflicting reports on the use of FDG PET in the evaluation of skeletal metastases. We report on a patient with locally advanced lung carcinoma in whom FDG PET accurately identified previously unsuspected widespread asymptomatic bone metastases (bone scan and X-rays negative, confirmed on MRI). Assessment of glucose metabolism with FDG PET might represent a more powerful tool to detect bone metastases in lung cancer compared with conventional bone scans. Copyright (2004) Blackwell Science Pty Ltd

  10. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  11. Diagnostic performance of 18F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis

    International Nuclear Information System (INIS)

    Treglia, Giorgio; Cocciolillo, Fabrizio; Castaldi, Paola; Rufini, Vittoria; Giordano, Alessandro; De Waure, Chiara; Di Nardo, Francesco; Gualano, Maria Rosaria

    2012-01-01

    The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of 18 F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). A comprehensive computer literature search of studies published through 30 June 2011 regarding 18 F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of 18 F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of 18 F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of 18 F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of 18 F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of 18 F-DOPA PET or PET/CT was found. A significant increase in sensitivity of 18 F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. In patients with suspected PG 18 F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. 18 F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false-negative results should be kept in mind. Furthermore

  12. Diagnostic performance of 18F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis.

    Science.gov (United States)

    Treglia, Giorgio; Cocciolillo, Fabrizio; de Waure, Chiara; Di Nardo, Francesco; Gualano, Maria Rosaria; Castaldi, Paola; Rufini, Vittoria; Giordano, Alessandro

    2012-07-01

    The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of (18)F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). A comprehensive computer literature search of studies published through 30 June 2011 regarding (18)F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of (18)F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of (18)F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of (18)F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of (18)F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of (18)F-DOPA PET or PET/CT was found. A significant increase in sensitivity of (18)F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. In patients with suspected PG (18)F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. (18)F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false-negative results should be kept in mind

  13. (18)F-FDG PET-CT simulation for non-small-cell lung cancer: effect in patients already staged by PET-CT.

    Science.gov (United States)

    Hanna, Gerard G; McAleese, Jonathan; Carson, Kathryn J; Stewart, David P; Cosgrove, Vivian P; Eakin, Ruth L; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H; Young, V A Linda; O'Sullivan, Joe M; Hounsell, Alan R

    2010-05-01

    Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV(CT) to GTV(FUSED) was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  14. 18F-FDG PET-CT Simulation for Non-Small-Cell Lung Cancer: Effect in Patients Already Staged by PET-CT

    International Nuclear Information System (INIS)

    Hanna, Gerard G.; McAleese, Jonathan; Carson, Kathryn J.; Stewart, David P.; Cosgrove, Vivian P.; Eakin, Ruth L.; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H.; Young, V.A. Linda D.C.R.; O'Sullivan, Joe M.

    2010-01-01

    Purpose: Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. Methods and Materials: A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. Results: PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV CT to GTV FUSED was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). Conclusion: PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  15. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer

    International Nuclear Information System (INIS)

    Ueda, Shigeto; Ishida, Jiro; Abe, Yoshiyuki; Mochizuki, Hidetaka; Tsuda, Hitoshi; Asakawa, Hideki; Omata, Jiro; Fukatsu, Kazuhiko; Kondo, Nobuo; Kondo, Tadaharu; Hama, Yukihiro; Tamura, Katsumi

    2008-01-01

    Accurate evaluation of axillary lymph node (ALN) involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18 F-fluorodeoxyglucose ( 18 F-FDG PET/CT) and axillary ultrasonography (AUS) for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18 F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB) and preoperative systemic chemotherapy (PSC). One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18 F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND). Using 18 F-FDG PET/CT, we studied both a visual assessment of 18 F-FDG uptake and standardized uptake value (SUV) for axillary staging. In a visual assessment of 18 F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18 F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18 F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12) in 18 F-FDG PET uptake only, 80% (4 of 5) in AUS positive only, and 100% (28 of 28) in dual positive. By the combination of AUS and 18 F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18 F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03). The diagnostic accuracy of 18 F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their limited sensitivities, the high radiation

  16. Impact of 18F-FDG PET/CT Staging in Newly Diagnosed Classical Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; Hutchings, Martin; Mylam, Karen Juul

    2013-01-01

    F-18-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) is a highly accurate staging method in classical Hodgkin lymphoma (cHL). We retrospectively compared the staging results obtained in two large cohorts of patients with cHL diagnosed before (n = 324) and after (n = 4...

  17. Contribution of positron emission tomography in pleural disease.

    Science.gov (United States)

    Duysinx, B; Corhay, J-L; Larock, M-P; Withofs, N; Bury, T; Hustinx, R; Louis, R

    2010-10-01

    Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumour in metastatic pleurisy and in monitoring chronic or recurrent pleural pathologies. PET should therefore be considered as a useful tool in the diagnosis of liquid or solid pleural pathologies. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  18. Positron emission tomography, physical bases and comparaison with other techniques

    International Nuclear Information System (INIS)

    Guermazi, Fadhel; Hamza, F; Amouri, W.; Charfeddine, S.; Kallel, S.; Jardak, I.

    2013-01-01

    Positron emission tomography (PET) is a medical imaging technique that measures the three-dimensional distribution of molecules marked by a positron-emitting particle. PET has grown significantly in clinical fields, particularly in oncology for diagnosis and therapeutic follow purposes. The technical evolutions of this technique are fast. Among the technical improvements, is the coupling of the PET scan with computed tomography (CT). PET is obtained by intravenous injection of a radioactive tracer. The marker is usually fluorine ( 18 F) embedded in a glucose molecule forming the 18-fluorodeoxyglucose (FDG-18). This tracer, similar to glucose, binds to tissues that consume large quantities of the sugar such cancerous tissue, cardiac muscle or brain. Detection using scintillation crystals (BGO, LSO, LYSO) suitable for high energy (511keV) recognizes the lines of the gamma photons originating from the annihilation of a positron with an electron. The electronics of detection or coincidence circuit is based on two criteria: a time window, of about 6 to 15 ns, and an energy window. This system measures the true coincidences that correspond to the detection of two photons of 511 kV from the same annihilation. Most PET devices are constituted by a series of elementary detectors distributed annularly around the patient. Each detector comprises a scintillation crystal matrix coupled to a finite number (4 or 6) of photomultipliers. The electronic circuit, or the coincidence circuit, determines the projection point of annihilation by means of two elementary detectors. The processing of such information must be extremely fast, considering the count rates encountered in practice. The information measured by the coincidence circuit is then positioned in a matrix or sinogram, which contains a set of elements of a projection section of the object. Images are obtained by tomographic reconstruction by powerful computer stations equipped with a software tools allowing the analysis and

  19. Prognostic Value of SUVmax Measured by Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography with Computed Tomography in Patients with Gallbladder Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Pil; Lim, Ilhan; Na, Im II; Cho, Eung Ho; Kim, Byung II; Choi, Chang Woon; Lim, Sang Moo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2014-06-15

    The aim of this study is to investigate the prognostic value of F-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET)/computed tomography (CT) in gallbladder cancer patients. From June 2004 to June 2010, a total of 50 patients with gallbladder cancer who underwent diagnostic staging with F-18 FDG PET/CT following curative or palliative treatments were retrospectively evaluated. For the analysis, all patients were classified by age, sex, maximum standardized uptake value (SUVmax), lymph node (LN) or distant metastasis, serum level of CA19-9 and CEA, type of treatment and American Joint Committee on Cancer (AJCC) stage. The median survival for the 50 patients was 245 days and the median SUVmax in PET/CT was 8.3 (range, 0-19.7). Patients with SUVmax<6 survived significantly longer than patients with SUVmax≥6 (median 405 days vs 203 days, p = 0.0400). On Kaplan-Meier analysis, SUVmax (p =0.0400), stage (p =0.0001), CA19-9 (p =0.013), CEA (p =0.006), LN metastasis (p =0.0001), distant metastasis (p =0.0020), type of treatment (p =0.0001) were significantly associated with overall survival. Multivariate analysis study revealed that the patients with lower SUVmax measured from initial staging PET/CT (p =0.0380), no LN metastasis (p =0.0260), a lower stage (p =0.026) and curative treatment (p =0.0005) had longer survivals. The present study shows that SUVmax on F-18 FDG PET/CT can provide prognostic information in patients with gallbladder cancer.

  20. Estimate of S-values for children due to six positron emitting radionuclides used in PET examinations

    Science.gov (United States)

    Belinato, Walmir; Santos, William S.; Perini, Ana P.; Neves, Lucio P.; Caldas, Linda V. E.; Souza, Divanizia N.

    2017-11-01

    Positron emission tomography (PET) has revolutionized the diagnosis of cancer since its conception. When combined with computed tomography (CT), PET/CT performed in children produces highly accurate diagnoses from images of regions affected by malignant tumors. Considering the high risk to children when exposed to ionizing radiation, a dosimetric study for PET/CT procedures is necessary. Specific absorbed fractions (SAF) were determined for monoenergetic photons and positrons, as well as the S-values for six positron emitting radionuclides (11C, 13N, 18F, 68Ga, 82Rb, 15O), and 22 source organs. The study was performed for six pediatric anthropomorphic hybrid models, including the newborn and 1 year hermaphrodite, 5 and 10-year-old male and female, using the Monte Carlo N-Particle eXtended code (MCNPX, version 2.7.0). The results of the SAF in source organs and S-values for all organs showed to be inversely related to the age of the phantoms, which includes the variation of body weight. The results also showed that radionuclides with higher energy peak emission produces larger auto absorbed S-values due to local dose deposition by positron decay. The S-values for the source organs are considerably larger due to the interaction of tissue with non-penetrating particles (electrons and positrons) and present a linear relationship with the phantom body masses. The results of the S-values determined for positron-emitting radionuclides can be used to assess the radiation dose delivered to pediatric patients subjected to PET examination in clinical settings. The novelty of this work is associated with the determination of auto absorbed S-values, in six new pediatric virtual anthropomorphic phantoms, for six emitting positrons, commonly employed in PET exams.

  1. Clinical PET/CT Atlas: A Casebook of Imaging in Oncology

    International Nuclear Information System (INIS)

    2015-01-01

    Integrated positron emission tomography/computed tomography (PET/CT) has evolved since its introduction into the commercial market more than a decade ago. It is now a key procedure, particularly in oncological imaging. Over the last years in routine clinical service, PET/CT has had a significant impact on diagnosis, treatment planning, staging, therapy, and monitoring of treatment response and has therefore played an important role in the care of cancer patients. The high sensitivity from the PET component and the specificity of the CT component give this hybrid imaging modality the unique characteristics that make PET/CT, even after over 10 years of clinical use, one of the fastest growing imaging modalities worldwide. This publication combines over 90 comprehensive cases covering all major indications of fluorodeoxyglucose (18F-FDG)-PET/CT as well as some cases of clinically relevant special tracers. The cases provide an overview of what the specific disease can look like in PET/CT, the typical pattern of the disease’s spread as well as likely pitfalls and teaching points. This PET/CT Atlas will allow professionals interested in PET/CT imaging to embrace the variety of oncological imaging by providing clinically relevant teaching files on the effectiveness and diagnostic quality of FDG-PET/CT imaging in routine applications

  2. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    Binderup, T.; El-Ali, H.H.; Skovgaard, D.

    2011-01-01

    is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small......Small animal positron emission tomography (PET) and computer tomography (CT) is an emerging field in pre-clinical imaging. High quality, state-of-the-art instruments are required for full optimization of the translational value of the small animal studies with PET and CT. However...... in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...

  3. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  4. PET and PET-CT. State of the art and future prospects

    International Nuclear Information System (INIS)

    Fanti, Stefano; Franchi, Roberto; Battista, Giuseppe; Monetti, Nino; Canini, Romeo

    2005-01-01

    Fluoro-deoxyglucose positron emission tomography (FDG PET) enables the in vivo study of tissue metabolism, and thus is able to identify malignant tumours as hypermetabolic lesions by an increase in tracer uptake. Many papers have demonstrated both the relevant impact of FDG PET on staging of many cancers and the superior accuracy of the technique compared with conventional diagnostic methods for pre-treatment evaluation, therapy response evaluation and relapse identification. In particular PET was found useful in identifying lymph nodal and metastatic spread. thus altering patient management in more than 30% of cases. PET images, however, provide limited anatomical data, which in regions such as the head and neck, mediastinum and pelvic cavity is a significant drawback. The exact localization of lesions may also be difficult in some cases, on the basis of PET images alone. The introduction of combined PET-computed tomography (PET-CT) scanners enables the almost simultaneous acquisition of transmission and emission images, thus obtaining optimal fusion images in a very short time. PET-CT fusion images enable lesions to be located, reducing false positive studies and increasing accuracy; the overall duration of examination may also be reduced. On the basis of both literature data and our experience we established the clinical indications when PET-CT may be particularly useful, in comparison with PET alone. It should also be underlined that the use of PET-CT is almost mandatory for new traces such as C-choline and C-methionine; these new tracers may be applied for studying tumours not assessable with FDG, such as prostate cancer. In conclusion PET-CT is at present the most advanced method for metabolic imaging, and is capable of precisely localizing and assessing tumours; fusion images reduce false positive and inconclusive studies, thus increasing diagnostic accuracy [it

  5. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems

    Science.gov (United States)

    Vaquero, Juan José; Kinahan, Paul

    2017-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges. PMID:26643024

  6. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

    Science.gov (United States)

    Vaquero, Juan José; Kinahan, Paul

    2015-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.

  7. The performance and application of 18F-FDG PET/CT in diagnosis of tumor

    International Nuclear Information System (INIS)

    Wang Junqi

    2004-01-01

    Positron emission tomography (PET)/computed tomography (CT) inline scanner combined with high performance PET and CT have been introduced to clinical in recent years. The application of PET/CT in oncology are rapid increasing. The addition of CT to PET offers many advantages, including obtaining a fast and relatively accurate transmission map, shortening the duration of the examination, adding precise anatomical information to PET imaging, and providing additional diagnostic information. However, using CT for attenuation correction can led to some artifacts; quantitative measurements may be altered, high density IV and oral metallic objects may produce artifacts, and the registration of PET and CT may occasionally suboptimal. In head and neck tumor PET/CT offers particular potential advantages as well as abdomen and pelvic tumor. Even in the thorax, which the physical movement may produce unsatisfactory results, offers some advantages also. Preliminary results of PET/CT over PET or CT in oncology are very encouraging. It is clear the PET/CT fusion technology has an more and more impact on both diagnostic and therapeutic aspects of patient management

  8. Impact of Endoscopic Ultrasonography on (18)F-FDG-PET/CT Upfront Towards Patient Specific Esophageal Cancer Treatment

    NARCIS (Netherlands)

    Hulshoff, J. B.; Mul, V. E. M.; de Boer, H. E. M.; Noordzij, W.; Korteweg, T.; van Dullemen, H. M.; Nagengast, W. B.; Oppedijk, V.; Pierie, J. P. E. N.; Plukker, John Th. M.

    INTRODUCTION: In patients with potentially resectable esophageal cancer (EC), the value of endoscopic ultrasonography (EUS) after fluorine-18 labeled fluorodeoxyglucose positron emission tomography with computed tomography ((18)F-FDG-PET/CT) is questionable. Retrospectively, we assessed the impact

  9. Multi-technique hybrid imaging in PET/CT and PET/MR: what does the future hold?

    International Nuclear Information System (INIS)

    Galiza Barbosa, F. de; Delso, G.; Voert, E.E.G.W. ter; Huellner, M.W.; Herrmann, K.; Veit-Haibach, P.

    2016-01-01

    Integrated positron-emission tomography and computed tomography (PET/CT) is one of the most important imaging techniques to have emerged in oncological practice in the last decade. Hybrid imaging, in general, remains a rapidly growing field, not only in developing countries, but also in western industrialised healthcare systems. A great deal of technological development and research is focused on improving hybrid imaging technology further and introducing new techniques, e.g., integrated PET and magnetic resonance imaging (PET/MRI). Additionally, there are several new PET tracers on the horizon, which have the potential to broaden clinical applications in hybrid imaging for diagnosis as well as therapy. This article aims to highlight some of the major technical and clinical advances that are currently taking place in PET/CT and PET/MRI that will potentially maintain the position of hybrid techniques at the forefront of medical imaging technologies.

  10. Monitoring variables affecting positron emission tomography measurements of cerebral blood flow in anaesthetized pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Zois, Nora Elisabeth; Simonsen, Mette

    Background: Positron emission tomography (PET) imaging of anaesthetised pig brains is a useful tool in neuroscience. Stable cerebral blood flow (CBF) is essential for PET, since variations can affect the kinetics of several radiotracers. However, the impact of physiological factors regulating CBF...

  11. Contribution of positron emission tomography in neurology

    International Nuclear Information System (INIS)

    Salmon, E.; Franck, G.

    1992-01-01

    Positron Emission Tomography (PET) is a scanner technique using tracers labelled with shortlived radioisotopes which allows to study and quantify human metabolic processes or drug pharmacology in vivo. The technique is first applied in physiological studies. Sleep, normal brain metabolism or cerebral activations have been studied. The pharmacological approach concerns both drug distribution in the human brain and blood flow or metabolic variations under treatment. Main neurological applications in pathology are cerebrovascular disorders, diseases leading to dementia, epilepsy, movement disorders, and brain tumors. In each field of application, PET gives unique and frequently early informations. It nicely combines both dynamic informations and measurement precision. (author)

  12. Comparison study of positron emission tomography, X-ray CT and MRI in Parkinsonism with dementia

    International Nuclear Information System (INIS)

    Okada, Junichi; Peppard, R.; Calne, D.B.

    1989-01-01

    Brain atrophy and local cerebral metabolic rate of glucose (LCMR-glc) in Parkinson's disease with dementia and Parkinsonism-dementia complex (PDC) were studied using positron emission tomography (PET) with F-18-2-deoxy-2-fluoro-D-glucose, X-ray CT and magnetic resonance imaging (MRI). The group of Parkinson's disease with dementia (n=7) had a significantly decreased LCMR-glc in all regions when compared with the age-matched normal group. In the group of Parkinson's disease without dementia (n=6), LCMR-glc was also significantly lower than the control group, although it was higher than the group with associated dementia. Some of the normal aged persons had cortical atrophy. There was no correlation between LCMR-glc and cortical atrophy. Six Guamnian patients had PDC associated with amyotrophic lateral sclerosis (ALS), and four patients had it without ALS. LCMR-glc did not differ in the two groups. It was, however, significantly lower than that in 5 Guamanian and 10 Caucasian normal persons. The group of PDC had a noticeable cortical atrophy and ventricular dilatation, regardless of the presence or absence of ALS. There was correlation between decrease of LCMR-glc and cortical atrophy of the frontal, parietal and temporal lobes. Parkinson's disease and PDC were different from Alzheimer's disease in which a decreased LCMR-glc has been reported to be usually confined to the cerebral cortex. Cortical atrophy and ventricular dilatation were depicted on MRI and CT in the PDC group, but did not in the group of Parkinson's disease. PET was useful in the functional examination and both MRI and CT were useful in the anatomical examination of these diseases. (Namekawa, K)

  13. Comparison study of positron emission tomography, X-ray CT and MRI in Parkinsonism with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Junichi; Peppard, R; Calne, D B

    1989-05-01

    Brain atrophy and local cerebral metabolic rate of glucose (LCMR-glc) in Parkinson's disease with dementia and Parkinsonism-dementia complex (PDC) were studied using positron emission tomography (PET) with F-18-2-deoxy-2-fluoro-D-glucose, X-ray CT and magnetic resonance imaging (MRI). The group of Parkinson's disease with dementia (n=7) had a significantly decreased LCMR-glc in all regions when compared with the age-matched normal group. In the group of Parkinson's disease without dementia (n=6), LCMR-glc was also significantly lower than the control group, although it was higher than the group with associated dementia. Some of the normal aged persons had cortical atrophy. There was no correlation between LCMR-glc and cortical atrophy. Six Guamnian patients had PDC associated with amyotrophic lateral sclerosis (ALS), and four patients had it without ALS. LCMR-glc did not differ in the two groups. It was, however, significantly lower than that in 5 Guamanian and 10 Caucasian normal persons. The group of PDC had a noticeable cortical atrophy and ventricular dilatation, regardless of the presence or absence of ALS. There was correlation between decrease of LCMR-glc and cortical atrophy of the frontal, parietal and temporal lobes. Parkinson's disease and PDC were different from Alzheimer's disease in which a decreased LCMR-glc has been reported to be usually confined to the cerebral cortex. Cortical atrophy and ventricular dilatation were depicted on MRI and CT in the PDC group, but did not in the group of Parkinson's disease. PET was useful in the functional examination and both MRI and CT were useful in the anatomical examination of these diseases. (Namekawa, K).

  14. Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Priscila do Carmo; Oliveira, Paulo Marcio Campos de; Mamede, Marcelo; Silveira, Mariana de Castro; Aguiar, Polyanna; Real, Raphaela Vila, E-mail: pridili@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Silva, Teogenes Augusto da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-01-15

    Objective: to evaluate the level of ambient radiation in a PET/CT center. Materials and methods: previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: in none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/ year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: in the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. (author)

  15. "6"8Gallium-arginine-glycine-aspartic acid and "1"8F-fluorodeoxyglucose position emission tomography/computed tomography in chondroblastic osteosarcoma of the skull

    International Nuclear Information System (INIS)

    Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike

    2017-01-01

    We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both "1"8[F]fluorodeoxyglucose ("1"8F-FDG) positron emission tomography/computed tomography (PET/CT) and "6"8Gallium-arginine-glycine-aspartic acid ("6"8Ga-RGD) PET/CT. The "1"8F-FDG PET/CT did not demonstrate the tumour, whereas the "6"8Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. "6"8Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of "1"8F-FDG PET in a setting of low glycolytic activity

  16. {sup 68}Gallium-arginine-glycine-aspartic acid and {sup 18}F-fluorodeoxyglucose position emission tomography/computed tomography in chondroblastic osteosarcoma of the skull

    Energy Technology Data Exchange (ETDEWEB)

    Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike [Dept. of Nuclear MedicineUniversity of Pretoria and Steve Biko Academic Hospital, Pretoria (South Africa)

    2017-09-15

    We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both {sup 18}[F]fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) and {sup 68}Gallium-arginine-glycine-aspartic acid ({sup 68}Ga-RGD) PET/CT. The {sup 18}F-FDG PET/CT did not demonstrate the tumour, whereas the {sup 68}Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. {sup 68}Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of {sup 18}F-FDG PET in a setting of low glycolytic activity.

  17. Impact of incidental findings on integrated 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in patients with gastric cancer.

    Science.gov (United States)

    Tae, Chung Hyun; Lee, Jun Haeng; Choi, Joon Young; Min, Byung-Hoon; Rhee, Poong-Lyul; Kim, Jae J

    2015-03-01

    Since positron emission tomography/computed tomography (PET/CT) has been introduced, many incidental findings have been identified. The aim of this study was to assess the clinical significance of incidental findings on PET/CT in patients with gastric cancer. A total of 421 patients with gastric cancer underwent PET/CT for initial staging. Incidental findings on PET/CT were classified into five categories according to clinical significance--normal variant, benign, probably benign, probably malignant, and definitely malignant. We obtained information regarding follow-up examinations, additional visits, final diagnosis of incidental findings and short-term medical costs for further evaluation. Eight hundred eighty-two incidental findings were detected in 386 (91.7%) patients. Of 274 incidental findings classified as probably benign, probably malignant or definitely malignant, 130 required one or more additional investigations. Finally, 12 (9.2%) were proved to be associated with second primary malignancy or metastasis of gastric cancer. One hundred twenty-nine additional outpatient visits and 10 additional hospitalizations were needed for evaluating the incidental findings. The treatment strategy for gastric cancer was changed in one patient. The estimated cost of additional investigations was $US283 (95% CI: $US248-$US311) per patient. Incidental findings on PET/CT were common. Although the incidental findings were suspicious of malignancy, most were benign with high costs for additional investigations. © 2015 Wiley Publishing Asia Pty Ltd.

  18. Speech processing system demonstrated by positron emission tomography (PET). A review of the literature

    International Nuclear Information System (INIS)

    Hirano, Shigeru; Naito, Yasushi; Kojima, Hisayoshi

    1996-01-01

    We review the literature on speech processing in the central nervous system as demonstrated by positron emission tomography (PET). Activation study using PET has been proved to be a useful and non-invasive method of investigating the speech processing system in normal subjects. In speech recognition, the auditory association areas and lexico-semantic areas called Wernicke's area play important roles. Broca's area, motor areas, supplementary motor cortices and the prefrontal area have been proved to be related to speech output. Visual speech stimulation activates not only the visual association areas but also the temporal region and prefrontal area, especially in lexico-semantic processing. Higher level speech processing, such as conversation which includes auditory processing, vocalization and thinking, activates broad areas in both hemispheres. This paper also discusses problems to be resolved in the future. (author) 42 refs

  19. Ambient radiation levels in a microPET/CT research laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sarmento, D.M.; Rodrigues, D.L.; Sanches, M.P.; Carneiro, J.C.G.G., E-mail: janetegc@ipen.br [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This study focuses on initial radiological evaluation and the exposure situation related to the worker task in a micro-positron emission tomography/computed tomography laboratory (microPET/CT). Selected and calibrated thermoluminescent dosimeters, TLD, of CaSO{sub 4}:Dy were used to measure room radiation levels. The detectors were placed in several selected points inside the microPET/CT laboratory and adjacent rooms. In addition, the occupationally exposed workers were monthly evaluated for external and internal exposures. In none of the selected points the dose values exceeded the radiation dose limit established for supervised area, as well as the values obtained in individual monitoring. (author)

  20. Ambient radiation levels in a microPET/CT research laboratory

    International Nuclear Information System (INIS)

    Sarmento, D.M.; Rodrigues, D.L.; Sanches, M.P.; Carneiro, J.C.G.G.

    2015-01-01

    This study focuses on initial radiological evaluation and the exposure situation related to the worker task in a micro-positron emission tomography/computed tomography laboratory (microPET/CT). Selected and calibrated thermoluminescent dosimeters, TLD, of CaSO 4 :Dy were used to measure room radiation levels. The detectors were placed in several selected points inside the microPET/CT laboratory and adjacent rooms. In addition, the occupationally exposed workers were monthly evaluated for external and internal exposures. In none of the selected points the dose values exceeded the radiation dose limit established for supervised area, as well as the values obtained in individual monitoring. (author)

  1. Pilot study utilizing Fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography for glycolytic phenotyping of canine mast cell tumors.

    Science.gov (United States)

    Griffin, Lynn R; Thamm, Doug H; Selmic, Laura E; Ehrhart, E J; Randall, Elissa

    2018-03-23

    The goal of this prospective pilot study was to use naturally occurring canine mast cell tumors of various grades and stages as a model for attempting to determine how glucose uptake and markers of biologic behavior are correlated. It was hypothesized that enhanced glucose uptake, as measured by 2-[fluorine-18]fluoro-d-glucose-positron emission tomography/computed tomography (F18 FDG PET-CT), would correlate with histologic grade. Dogs were recruited for this study from a population referred for treatment of cytologically or histologically confirmed mast cell tumors. Patients were staged utilizing standard of care methods (abdominal ultrasound and three view thoracic radiographs), followed by a whole body F18 FDG PET-CT. Results of the F18 FDG PET-CT were analyzed for possible metastasis and standard uptake value maximum (SUV max ) of identified lesions. Incisional or excisional biopsies of the accessible mast cell tumors were obtained and histology performed. Results were then analyzed to look for a possible correlation between the grade of mast cell tumors and SUV max . A total of nine animals were included in the sample. Findings indicated that there was a correlation between grade of mast cell tumors and SUV max as determined by F18 FDG PET-CT (p-value = 0.073, significance ≤ 0.1). Based on the limited power of this study, it is felt that further research to examine the relationship between glucose utilization and biologic aggressiveness in canine mast cell tumors is warranted. This study was unable to show that F18 FDG PET-CT was a better staging tool than standard of care methods. © 2018 American College of Veterinary Radiology.

  2. Evaluation of scintillators and semiconductor detectors to image three-photon positron annihilation for positron emission tomography

    International Nuclear Information System (INIS)

    Abuelhia, E.; Spyrou, N.M.; Kacperski, K.; College University, Middlesex Hospital, London

    2008-01-01

    Positron emission tomography (PET) is rapidly becoming the main nuclear imaging modality of the present century. The future of PET instrumentation relies on semiconductor detectors because of their excellent characteristics. Three-photon positron annihilation has been recently investigated as a novel imaging modality, which demands the crucial high energy resolution of semiconductor detector. In this work the evaluation of the NaI(Tl) scintillator and HPGe and CdZTe semiconductor detectors, to construct a simple three-photon positron annihilation scanner has been explored. The effect of detector and scanner size on spatial resolution (FWHM) is discussed. The characteristics: energy resolution versus count rate and point-spread function of the three-photon positron annihilation image profile from triple coincidence measurements were investigated. (author)

  3. Primary central nervous system lymphoma in an human immunodeficiency virus-infected patient mimicking bilateral eye sign in brain seen in fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusany; Thirugnanam, Rajasekar; Shibu, Deepu; Kalarikal, Radhakrishnan Edathurthy; Shinto, Ajit Sugunan

    2014-04-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG PET/CT) has proven useful in the diagnosis, staging, and detection of metastasis and posttreatment monitoring of several malignancies in human immunodeficiency virus (HIV)-infected patients. It also has the ability to make the important distinction between malignancy and infection in the evaluation of central nervous system (CNS) lesions, leading to the initiation of the appropriate treatment and precluding the need for invasive biopsy. We report an interesting case of HIV positive 35-year-old woman presented with headache, disorientation, and decreased level of consciousness. She underwent whole body PET/CT which showed multiple lesions in the cerebrum which mimics bilateral eye in brain. A diagnosis of a primary CNS lymphoma was made and patient was started on chemotherapy.

  4. Primary central nervous system lymphoma in an human immunodeficiency virus-infected patient mimicking bilateral eye sign in brain seen in fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusany; Thirugnanam, Rajasekar; Shibu, Deepu; Kalarikal, Radhakrishnan Edathurthy; Shinto, Ajit Sugunan

    2014-01-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG PET/CT) has proven useful in the diagnosis, staging, and detection of metastasis and posttreatment monitoring of several malignancies in human immunodeficiency virus (HIV)-infected patients. It also has the ability to make the important distinction between malignancy and infection in the evaluation of central nervous system (CNS) lesions, leading to the initiation of the appropriate treatment and precluding the need for invasive biopsy. We report an interesting case of HIV positive 35-year-old woman presented with headache, disorientation, and decreased level of consciousness. She underwent whole body PET/CT which showed multiple lesions in the cerebrum which mimics bilateral eye in brain. A diagnosis of a primary CNS lymphoma was made and patient was started on chemotherapy

  5. The willingness to pay for positron emission tomography (PET). Evaluation of suspected lung cancer using contingent valuation

    International Nuclear Information System (INIS)

    Papatheofanis, F.J.

    2000-01-01

    In this study, contingent valuation is used to estimate the willingness-to-pay (WTP) for positron emission tomography (PET) imaging by patients with suspected benign or malignant lung disease. Patients (n=87) undergoing thoracic computed tomography were surveyed for their WTP for PET for the evaluation of lung disease in lieu of further testing. Patients were provided background PET information and a two-page self-administered questionnaire. The survey queried basic demographic information, perceived risk of malignancy, and perceived life expectancy given a diagnosis of malignancy. Patients with increased perception of risk were willing to pay more than those with lower perceived risk. Patients who were self-payers for their health insurance indicated a lower WTP than those who did not pay any out-of-pocket insurance premiums. Individuals are willing to pay additional out-of-pocket costs for diagnostic imaging to reduce their perception of risk and improve their quality of life

  6. Comparison of 131I whole-body imaging, 131I SPECT/CT, and 18F-FDG PET/CT in the detection of metastatic thyroid cancer

    International Nuclear Information System (INIS)

    Oh, Jong-Ryool; Chong, Ari; Kim, Jahae; Kang, Sae-Ryung; Song, Ho-Chun; Bom, Hee-Seung; Byun, Byung-Hyun; Hong, Sun-Pyo; Yoo, Su-Woong; Kim, Dong-Yeon; Min, Jung-Joon

    2011-01-01

    The aim of this study was to compare 131 I whole-body scintigraphy (WBS), WBS with 131 I single photon emission computed tomography/computed tomography (SPECT/CT), and 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the detection of distant metastases of differentiated thyroid cancer (DTC). A total of 140 patients with 258 foci of suspected distant metastases were evaluated. 131 I WBS, 131 I SPECT/CT, and 18 F-FDG PET/CT images were interpreted separately. The final diagnosis was obtained from histopathologic study, serum thyroglobulin level, other imaging modalities, and/or clinical follow-up. Of the 140 patients with 258 foci, 46 patients with 166 foci were diagnosed as positive for distant metastasis. The sensitivity, specificity, and diagnostic accuracy of each imaging modality were 65, 55, and 59%, respectively, for 131 I WBS; 65, 95, and 85% for 131 I SPECT/CT, respectively; and 61, 98, and 86%, respectively, for 18 F-FDG PET/CT in patient-based analyses. Lesion-based analyses demonstrated that both SPECT/CT and PET/CT were superior to WBS (p 18 F-FDG PET/CT presented the highest diagnostic performance in patients who underwent multiple challenges of radioiodine therapy. (orig.)

  7. Positron Emission Tomography (PET in Oncology

    Directory of Open Access Journals (Sweden)

    Andrea Gallamini

    2014-09-01

    Full Text Available Since its introduction in the early nineties as a promising functional imaging technique in the management of neoplastic disorders, FDG-PET, and subsequently FDG-PET/CT, has become a cornerstone in several oncologic procedures such as tumor staging and restaging, treatment efficacy assessment during or after treatment end and radiotherapy planning. Moreover, the continuous technological progress of image generation and the introduction of sophisticated software to use PET scan as a biomarker paved the way to calculate new prognostic markers such as the metabolic tumor volume (MTV and the total amount of tumor glycolysis (TLG. FDG-PET/CT proved more sensitive than contrast-enhanced CT scan in staging of several type of lymphoma or in detecting widespread tumor dissemination in several solid cancers, such as breast, lung, colon, ovary and head and neck carcinoma. As a consequence the stage of patients was upgraded, with a change of treatment in 10%–15% of them. One of the most evident advantages of FDG-PET was its ability to detect, very early during treatment, significant changes in glucose metabolism or even complete shutoff of the neoplastic cell metabolism as a surrogate of tumor chemosensitivity assessment. This could enable clinicians to detect much earlier the effectiveness of a given antineoplastic treatment, as compared to the traditional radiological detection of tumor shrinkage, which usually takes time and occurs much later.

  8. Positron Emission Tomography (PET) in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Gallamini, Andrea, E-mail: gallamini.a@ospedale.cuneo.it [Department of Research and Medical Innovation, Antoine Lacassagne Cancer Center, Nice University, Nice Cedex 2-06189 Nice (France); Zwarthoed, Colette [Department of Nuclear Medicine, Antoine Lacassagne Cancer Center, Nice University, Nice Cedex 2-06189 Nice (France); Borra, Anna [Hematology Department S. Croce Hospital, Via M. Coppino 26, Cuneo 12100 (Italy)

    2014-09-29

    Since its introduction in the early nineties as a promising functional imaging technique in the management of neoplastic disorders, FDG-PET, and subsequently FDG-PET/CT, has become a cornerstone in several oncologic procedures such as tumor staging and restaging, treatment efficacy assessment during or after treatment end and radiotherapy planning. Moreover, the continuous technological progress of image generation and the introduction of sophisticated software to use PET scan as a biomarker paved the way to calculate new prognostic markers such as the metabolic tumor volume (MTV) and the total amount of tumor glycolysis (TLG). FDG-PET/CT proved more sensitive than contrast-enhanced CT scan in staging of several type of lymphoma or in detecting widespread tumor dissemination in several solid cancers, such as breast, lung, colon, ovary and head and neck carcinoma. As a consequence the stage of patients was upgraded, with a change of treatment in 10%–15% of them. One of the most evident advantages of FDG-PET was its ability to detect, very early during treatment, significant changes in glucose metabolism or even complete shutoff of the neoplastic cell metabolism as a surrogate of tumor chemosensitivity assessment. This could enable clinicians to detect much earlier the effectiveness of a given antineoplastic treatment, as compared to the traditional radiological detection of tumor shrinkage, which usually takes time and occurs much later.

  9. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  10. A case of positive 68Ga-DOTATOC-PET/CT pancreatic heterotopia mimicking an intestinal neuroendocrine tumor.

    Science.gov (United States)

    Zilli, Alessandra; Fanetti, Ilaria; Conte, Dario; Massironi, Sara

    Gallium-68 DOTA-peptide positron emission tomography/computed tomography ( 68 Ga-PET/CT) has emerged as a promising tool for the diagnosis and staging of gastro-entero-pancreatic neoplasms, thanks to its high sensitivity and specificity. Heterotopic pancreas, which is relatively rare, has never been reported as a possible cause of false positives of 68 Ga-PET/CT. We report on the first case of a heterotopic pancreas showing pathological uptake at 68 Ga-PET/CT, thus mimicking an intestinal neuroendocrine tumor. The present case suggests that heterotopic pancreas should be included among the possible causes of false positives at 68 Ga PET. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. FDG-PET/CT in the diagnosis of recurrent breast cancer

    International Nuclear Information System (INIS)

    Murakami, Ryusuke; Kumita, Shin-ichiro; Yoshida, Tamiko; Ishihara, Keiichi; Kiriyama, Tomonari; Hakozaki, Kenta; Yanagihara, Keiko; Lida, Shinya; Tsuchiya, Shin-ichi

    2012-01-01

    Background. An advantage of PET/CT has been demonstrated for diagnosis of several tumor entities. In patients with breast cancer, early diagnosis and accurate restaging of recurrence after surgery is important for selection of the most appropriate therapeutic strategy. Purpose. To evaluate the accuracy of integrated positron emission tomography and computed tomography (PET/CT) using 18F-fluorodeoxyglucose (FDG), for follow-up of patients with suspected recurrent breast cancer. Material and Methods. Forty-seven patients with suspected recurrent breast cancer underwent PET/CT. The PET and PET/CT images were interpreted without knowledge of the results of other diagnostic modalities, and compared with each other with reference to the final diagnosis. Results. Twenty-five (53%) patients suffered tumor recurrence. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PET/CT were 96%, 91%, 92%, 95%, and 94%, respectively. In comparison with PET, PET/CT had a higher sensitivity and accuracy (96% vs. 80% and 94% vs. 81%, respectively). The difference in diagnostic accuracy between PET/CT and PET was significant (P < 0.05). Conclusion. The present findings indicate that PET/CT is an accurate, sensitive and reliable modality for screening and detection of breast cancer recurrence. PET/CT appears to be an effective surveillance tool, as it is able to cover the whole body in a single procedure and shows good performance

  12. The value of F-18 fluorodeoxyglucose positron emission tomography/computed tomography in asymptomatic examinees with unexplained elevated blood carcinoembryonic antigen levels

    Energy Technology Data Exchange (ETDEWEB)

    Li, Wenfeng [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Radiation Oncology, Wenzhou (China); Yin, Weiwei [The First Affiliated Hospital of Wenzhou Medical University, Division of PET/CT, Department of Radiology, Wenzhou (China); Ou, Rongying [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Gynaecology and Obstetrics, Wenzhou (China); Chen, Ting; Xiong, Lingling; Xu, Yunsheng [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Dermatovenereology, Wenzhou (China); Cheng, Dezhi; Xie, Deyao [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Cardiothoracic Surgery, Wenzhou (China); Zheng, Xiangwu; Zhao, Liang [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Division of PET/CT, Department of Radiology, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Institutes of Intelligent and Molecular Imaging, Wenzhou (China)

    2016-04-15

    Cancer is still a clinical challenge, with many efforts invested in order to achieve timely detection. Unexplained elevated blood carcinoembryonic antigen levels are occasionally observed in an asymptomatic population and considered as a risk factor of cancers. The purpose of this study was to determine the validity of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography (F-18 FDG-PET/CT) for detecting cancer in an asymptomatic population with an unexplained elevation in blood carcinoembryonic antigen (CEA) levels. This retrospective study included a total of 1920 asymptomatic examinees conducted from August 2011 through September 2013. The participants underwent CEA assay and conventional medical imaging (CEA-conventional), or CEA assay and F-18 FDG-PET/CT (CEA-PET/CT). The validity of conventional medical imaging and CEA-PET/CT scanning for detecting cancer and early-stage cancer in an asymptomatic population with an unexplained elevation in blood CEA levels were evaluated. Sensitivity, specificity, cancer detection rate, missed cancer detection rate, early-stage cancer detection rate, and early-stage cancer ratio using the CEA-PET/CT scanning were 96.6 %, 100 %, 10.4 %, 0.4 %, 3.7 %, and 34.5 %, respectively. In contrast, the corresponding values obtained using the conventional medical imaging were 50.6 % (P < 0.0001), 100 % (P > 0.9999), 50.6 % (P < 0.0001), 99.9 % (P = 0.055), 2.6 % (P < 0.0001), 2.5 % (P = 0.04), 0.7 % (P = 0.0004), and 14.5 % (P = 0.002), respectively. The F-18 FDG-PET/CT scanning significantly improved the validity of the cancer detection program in the asymptomatic population with an unexplained elevation in CEA levels. (orig.)

  13. Pure ground glass nodular adenocarcinomas: Are preoperative positron emission tomography/computed tomography and brain magnetic resonance imaging useful or necessary?

    Science.gov (United States)

    Cho, Hyoun; Lee, Ho Yun; Kim, Jhingook; Kim, Hong Kwan; Choi, Joon Young; Um, Sang-Won; Lee, Kyung Soo

    2015-09-01

    The utility of (18)F-Fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning and brain magnetic resonance imaging (MRI) as a staging workup for lung adenocarcinoma manifesting as pure ground glass opacity (GGO) is unknown. The purpose of this study was to determine the utility of these 2 tests for preoperative staging of pure GGO nodular lung adenocarcinoma. The study included 164 patients (male:female, 73:91; mean age, 62 years) with pure GGO nodular lung adenocarcinoma who underwent PET/CT (in 136 patients) and/or brain MRI (in 109 patients) before surgery. Pathologic N staging and dedicated standard imaging or follow-up imaging findings for M staging were used as reference standards. The median follow-up time was 47.9 months. On PET/CT scan, abnormal FDG uptake of lymph nodes was found in 2 of 136 patients (1.5%); both were negative on final pathology. Abnormal FDG uptake of the liver was detected in 1 patient, which was also confirmed to be negative by dedicated abdominal CT. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of PET/CT in detecting metastases were not applicable, 98% (95% confidence interval [CI], 94%-100%), 0% (95% CI, 0%-71%), 100% (95% CI, 97%-100%), and 98% (95% CI, 94%-100%), respectively. No brain metastasis was found in preoperative brain MRI of 109 patients. Of 109 patients, 1 (0.9%) developed brain metastasis 30 months after surgical resection. PET/CT and brain MRI is not necessary in the staging of pure GGO nodular lung adenocarcinoma. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  14. Positron emission tomography and [{sup 18}F]BPA: A perspective application to assess tumour extraction of boron in BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Menichetti, L. [Department of PET and Radiopharmaceutical Chemistry, C.N.R. Institute of Clinical Physiology, Pisa (Italy)], E-mail: luca.menichetti@ifc.cnr.it; Cionini, L. [Unit of Radiotherapy, AOUP-University Hospital, Pisa (Italy); Sauerwein, W.A. [Department of Radiation Oncology, University Duisburg-Essen, University Hospital Essen (Germany); Altieri, S. [University of Pavia, Department of Nuclear Physics, Pavia (Italy); Solin, O.; Minn, H. [Turku PET Centre, University of Turku (Finland); Salvadori, P.A. [Department of PET and Radiopharmaceutical Chemistry, C.N.R. Institute of Clinical Physiology, Pisa (Italy)

    2009-07-15

    Positron emission tomography (PET) has become a key imaging tool in clinical practice and biomedical research to quantify and study biochemical processes in vivo. Physiologically active compounds are tagged with positron emitters (e.g. {sup 18}F, {sup 11}C, {sup 124}I) while maintaining their biological properties, and are administered intravenously in tracer amounts (10{sup -9}-10{sup -12} M quantities). The recent physical integration of PET and computed tomography (CT) in hybrid PET/CT scanners allows a combined anatomical and functional imaging: nowadays PET molecular imaging is emerging as powerful pharmacological tool in oncology, neurology and for treatment planning as guidance for radiation therapy. The in vivo pharmacokinetics of boron carrier for BNCT and the quantification of {sup 10}B in living tissue were performed by PET in the late nineties using compartmental models based on PET data. Nowadays PET and PET/CT have been used to address the issue of pharmacokinetic, metabolism and accumulation of BPA in target tissue. The added value of the use of L-[{sup 18}F]FBPA and PET/CT in BNCT is to provide key data on the tumour extraction of {sup 10}B-BPA versus normal tissue and to predict the efficacy of the treatment based on a single-study patient analysis. Due to the complexity of a binary treatment like BNCT, the role of PET/CT is currently to design new criteria for patient enrolment in treatment protocols: the L-[{sup 18}F]BPA/PET methodology could be considered as an important tool in newly designed clinical trials to better estimate the concentration ratio of BPA in the tumour as compared to neighbouring normal tissues. Based on these values for individual patients the decision could be made whether BNCT treatment could be advantageous due to a selective accumulation of BPA in an individual tumour. This approach, applicable in different tumour entities like melanoma, glioblastoma and head and neck malignancies, make this methodology as reliable

  15. Detection of penile metastasis from bladder cancer using F 18 FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yun; Lee, Jong Jin [Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-12-15

    A 74 year old man who had experienced priapism for 2 months after radical cystectomy for bladder cancer visited our hospital, and underwent metastatic work up {sup 18}F fluorodeoxyglucose (FDG) positron emission tomography/computed tomography(PET/CT)showed diffuse hypermetabolic activity along the penis shaft, which was confirmed as a penile metastasis.

  16. FDG-PET/CT Brain Findings in a Patient With Macrophagic Myofasciitis

    OpenAIRE

    Van Der Gucht, Axel; Aoun-Sebaiti, Mehdi; Kauv, Paul; Guedj, Eric; Aouizerate, Jessie; Verger, Antoine; Gherardi, Romain K.; Bachoud-Levi, Anne-Catherine; Authier, Fran?ois-J?r?me; Itti, Emmanuel

    2015-01-01

    Brain Positron Emission Tomography/Computed Tomography with 18F-fluorodeoxyglucose (FDG PET/CT) was performed in a 44-year-old woman with marked cognitive impairment, diffuse myalgias, sensory, memory and visual disorders, and chronic fatigue, presenting with histopathological features of macrophagic myofasciitis (MMF) at deltoid muscle biopsy. Cerebromedullary Magnetic Resonance Imaging (MRI), electromyography, ophthalmic examination, and cerebrospinal fluid analysis were normal. Visual anal...

  17. Comparison of dosimetry between PET/CT and PET alone using 11C-ITMM

    International Nuclear Information System (INIS)

    Ito, Kimiteru; Sakata, Muneyuki; Wagarsuma, Kei; Toyohara, Jun; Ishibashi, Kenji; Ishii, Kenji; Ishiwata, Kiichi; Oda, Keiichi

    2016-01-01

    We used a new tracer, N-[4-[6-(isopropylamino) pyrimidin-4-yl]-1,3-thiazol-2-yl]-4- 11 C-methoxy-N-methylbenzamide ( 11 C-ITMM), to compare radiation doses from positron emission tomography (PET)/computed tomography (CT) with previously published doses from PET alone. Twelve healthy volunteers [six males (mean age ± SD, 27.7 ± 6.7 years) and six females (31.8 ± 14.5 years)] in 12 examinations were recruited. Dose estimations from PET/CT were compared with those from PET alone. Regions of interest (ROIs) in PET/CT were delineated on the basis of low-dose CT (LD-CT) images acquired during PET/CT. Internal and external radiation doses were estimated using OLINDA/EXM 1.0 and CT-Expo software. The effective dose (ED) for 11 C-ITMM calculated from PET/CT was estimated to be 4.7 ± 0.5 μSv/MBq for the male subjects and 4.1 ± 0.7 μSv/MBq for the female subjects. The mean ED for 11 C-ITMM calculated from PET alone in a previous report was estimated to be 4.6 ± 0.3 μSv/MBq (males, n = 3). The ED values for 11 C-ITMM calculated from PET/CT in the male subjects were almost identical to those from PET alone. The absorbed doses (ADs) of the gallbladder, stomach, red bone marrow, and spleen calculated from PET/CT were significantly different from those calculated from PET alone. The EDs of 11 C-ITMM calculated from PET/CT were almost identical to those calculated from PET alone. The ADs in several organs calculated from PET/CT differed from those from PET alone. LD-CT images acquired during PET/CT may facilitate organ identification.

  18. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    International Nuclear Information System (INIS)

    Yeung, Timothy P C; Yartsev, Slav; Lee, Ting-Yim; Wong, Eugene; He, Wenqing; Fisher, Barbara; VanderSpek, Lauren L; Macdonald, David; Bauman, Glenn

    2014-01-01

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity

  19. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Timothy P C [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Lee, Ting-Yim [Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Imaging, The University of Western Ontario, London Health Sciences Centre, Victoria Hospital, Ontario, Canada, N6A 5W9 (Australia); Lawson Health Research Institute, St. Joseph' s Health Care London, Ontario, Canada, N6A 4V2 (Canada); Wong, Eugene [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Physics and Astronomy, The University of Western Ontario, Ontario, Canada, N6A 3K7 (Canada); He, Wenqing [Department of Statistical and Actuarial Sciences, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Fisher, Barbara; VanderSpek, Lauren L [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Macdonald, David [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Clinical Neurological Sciences, The University of Western Ontario, London Health Sciences Centre, University Hospital, Ontario, Canada, N6A 5A5 (Canada); Bauman, Glenn, E-mail: glenn.bauman@lhsc.on.ca [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada)

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  20. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  1. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  2. Evaluation of brain tumours by positron emission tomography

    International Nuclear Information System (INIS)

    Schober, O.; Meyer, G.J.

    1992-01-01

    The clinical application of positron emission tomography (PET) for the evaluation of brain tumours has proved clinically valuable. Amino acid and FDG-glucose PET provide information on the degree of malignancy and the prognosis during the initial evaluation. After therapy, the residual tumour can be visualized and recurrence can be differentiated from necrosis. Amino acids have advantages over FDG for these clinical applications. Blood flow, oxygen extraction and metabolism and blood-brain barrier permeability are of minor relevance in clinical situations. Comparison of PET with MRI and MRS will provide new data. The quantitative information of the unique information yielded by PET will lead to a more important clinical role, as will the extrapolation of this experience to the SPECT technique. (orig.) [de

  3. PET/CT for the staging and follow-up of patients with malignancies

    International Nuclear Information System (INIS)

    Poeppel, T.D.; Krause, B.J.; Heusner, T.A.; Boy, C.; Bockisch, A.; Antoch, G.

    2009-01-01

    Positron emission tomography (PET) and computed tomography (CT) complement each other's strengths in integrated PET/CT. PET is a highly sensitive modality to depict the whole-body distribution of positron-emitting biomarkers indicating tumour metabolic activity. However, conventional PET imaging is lacking detailed anatomical information to precisely localise pathologic findings. CT imaging can readily provide the required morphological data. Thus, integrated PET/CT represents an efficient tool for whole-body staging and functional assessment within one examination. Due to developments in system technology PET/CT devices are continually gaining spatial resolution and imaging speed. Whole-body imaging from the head to the upper thighs is accomplished in less than 20 min. Spatial resolution approaches 2-4 mm. Most PET/CT studies in oncology are performed with 18 F-labelled fluoro-deoxy-D-glucose (FDG). FDG is a glucose analogue that is taken up and trapped within viable cells. An increased glycolytic activity is a characteristic in many types of cancers resulting in avid accumulation of FDG. These tumours excel as 'hot spots' in FDG-PET/CT imaging. FDG-PET/CT proved to be of high diagnostic value in staging and restaging of different malignant diseases, such as colorectal cancer, lung cancer, breast cancer, head and neck cancer, malignant lymphomas, and many more. The standard whole-body coverage simplifies staging and speeds up decision processes to determine appropriate therapeutic strategies. Further development and implementation of new PET-tracers in clinical routine will continually increase the number of PET/CT indications. This promotes PET/CT as the imaging modality of choice for working-up of the most common tumour entities as well as some of the rare malignancies.

  4. Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center

    Science.gov (United States)

    Santana, Priscila do Carmo; de Oliveira, Paulo Marcio Campos; Mamede, Marcelo; Silveira, Mariana de Castro; Aguiar, Polyanna; Real, Raphaela Vila; da Silva, Teógenes Augusto

    2015-01-01

    Objective To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. PMID:25798004

  5. A phase I study on stereotactic body radiotherapy of liver metastases based on functional treatment planning using positron emission tomography with 2-[(18)F]fluoro-2-deoxy-d-galactose

    DEFF Research Database (Denmark)

    Fode, Mette Marie; Bak-Fredslund, Kirstine; Petersen, Jørgen Baltzer

    2017-01-01

    BACKGROUND AND PURPOSE: The galactose analog 2-[18F]fluoro-2-deoxy-d-galactose (FDGal) is used for quantification of regional hepatic metabolic capacity by functional positron emission tomography computerized tomography (PET/CT). In the present study, FDGal PET/CT was used for functional treatment...... planning (FTP) of stereotactic body radiotherapy (SBRT) of liver metastases with the aim of minimizing radiation dose to the best functioning liver tissue. MATERIAL AND METHODS: Fourteen patients referred for SBRT had FDGal PET/CT performed before and one month after the treatment. The planning CT...... and the FDGal PET/CT images were deformable co-registered. RESULTS: A reduction in the mean dose of approximately 2 Gy to the best functioning sub-volumes was obtained. One patient developed grade 2 acute morbidity and no patients experienced grade 3 or higher acute morbidities. The regional hepatic metabolic...

  6. Monte Carlo simulation of simultaneous radiation detection in the hybrid tomography system ClearPET-XPAD3/CT

    Energy Technology Data Exchange (ETDEWEB)

    Dávila, H. Olaya, E-mail: hernan.olaya@uptc.edu.co; Martínez, S. A. [Physics Department, Universidad Pedagógica y Tecnológica de Colombia, Tunja-Colombia (Colombia); Sevilla, A. C., E-mail: acsevillam@unal.edu.co; Castro, H. F. [Physics Department, Universidad Nacional de Colombia, Bogotá D.C - Colombia (Colombia)

    2016-07-07

    Using the Geant4 based simulation framework SciFW1, a detailed simulation was performed for a detector array in the hybrid tomography prototype for small animals called ClearPET / XPAD, which was built in the Centre de Physique des Particules de Marseille. The detector system consists of an array of phoswich scintillation detectors: LSO (Lutetium Oxy-ortosilicate doped with cerium Lu{sub 2}SiO{sub 5}:Ce) and LuYAP (Lutetium Ortoaluminate of Yttrium doped with cerium Lu{sub 0.7}Y{sub 0.3}AlO{sub 3}:Ce) for Positron Emission Tomography (PET) and hybrid pixel detector XPAD for Computed Tomography (CT). Simultaneous acquisition of deposited energy and the corresponding time - position for each recorded event were analyzed, independently, for both detectors. interference between detection modules for PET and CT. Information about amount of radiation reaching each phoswich crystal and XPAD detector using a phantom in order to study the effectiveness by radiation attenuation and influence the positioning of the radioactive source {sup 22}Na was obtained. The simulation proposed will improve distribution of detectors rings and interference values will be taken into account in the new versions of detectors.

  7. Monte Carlo simulation of simultaneous radiation detection in the hybrid tomography system ClearPET-XPAD3/CT

    Science.gov (United States)

    Dávila, H. Olaya; Sevilla, A. C.; Castro, H. F.; Martínez, S. A.

    2016-07-01

    Using the Geant4 based simulation framework SciFW1, a detailed simulation was performed for a detector array in the hybrid tomography prototype for small animals called ClearPET / XPAD, which was built in the Centre de Physique des Particules de Marseille. The detector system consists of an array of phoswich scintillation detectors: LSO (Lutetium Oxy-ortosilicate doped with cerium Lu2SiO5:Ce) and LuYAP (Lutetium Ortoaluminate of Yttrium doped with cerium Lu0.7Y0.3AlO3:Ce) for Positron Emission Tomography (PET) and hybrid pixel detector XPAD for Computed Tomography (CT). Simultaneous acquisition of deposited energy and the corresponding time - position for each recorded event were analyzed, independently, for both detectors. interference between detection modules for PET and CT. Information about amount of radiation reaching each phoswich crystal and XPAD detector using a phantom in order to study the effectiveness by radiation attenuation and influence the positioning of the radioactive source 22Na was obtained. The simulation proposed will improve distribution of detectors rings and interference values will be taken into account in the new versions of detectors.

  8. Impacts of biological and procedural factors on semiquantification uptake value of liver in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Mahmud, Mohd Hafizi; Nordin, Abdul Jalil; Ahmad Saad, Fathinul Fikri; Azman, Ahmad Zaid Fattah

    2015-10-01

    Increased metabolic activity of fluorodeoxyglucose (FDG) in tissue is not only resulting of pathological uptake, but due to physiological uptake as well. This study aimed to determine the impacts of biological and procedural factors on FDG uptake of liver in whole body positron emission tomography/computed tomography (PET/CT) imaging. Whole body fluorine-18 ((18)F) FDG PET/CT scans of 51 oncology patients have been reviewed. Maximum standardized uptake value (SUVmax) of lesion-free liver was quantified in each patient. Pearson correlation was performed to determine the association between the factors of age, body mass index (BMI), blood glucose level, FDG dose and incubation period and liver SUVmax. Multivariate regression analysis was established to determine the significant factors that best predicted the liver SUVmax. Then the subjects were dichotomised into four BMI groups. Analysis of variance (ANOVA) was established for mean difference of SUVmax of liver between those BMI groups. BMI and incubation period were significantly associated with liver SUVmax. These factors were accounted for 29.6% of the liver SUVmax variance. Statistically significant differences were observed in the mean SUVmax of liver among those BMI groups (Pvalue for physiological liver SUVmax as a reference standard for different BMI of patients in PET/CT interpretation and use a standard protocol for incubation period of patient to reduce variation in physiological FDG uptake of liver in PET/CT study.

  9. [(18)F]-fluorocholine positron-emission/computed tomography for lymph node staging of patients with prostate cancer: preliminary results of a prospective study

    DEFF Research Database (Denmark)

    Poulsen, Mads H; Bouchelouche, Kirsten; Gerke, Oke

    2010-01-01

    Study Type - Diagnostic (case series) Level of Evidence 4 OBJECTIVES To evaluate prospectively [(18)F]-fluorocholine positron-emission/computed tomography (FCH PET/CT) for lymph node staging of prostate cancer before intended curative therapy, and to determine whether imaging 15 or 60 min after......; the corresponding 95% confidence intervals were 29.2-100%, 77.2-99.9%, 19.4-99.4% and 83.9-100%, respectively. Values of SUV(max) at early and late imaging were not significantly different. CONCLUSIONS This small series supports the use of FCH PET/CT as a tool for lymph node staging of patients with prostate cancer...

  10. Diagnostic performance of {sup 18}F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Treglia, Giorgio; Cocciolillo, Fabrizio; Castaldi, Paola; Rufini, Vittoria; Giordano, Alessandro [Catholic University of the Sacred Heart, Institute of Nuclear Medicine, Rome (Italy); De Waure, Chiara; Di Nardo, Francesco; Gualano, Maria Rosaria [Catholic University of the Sacred Heart, Institute of Hygiene, Rome (Italy)

    2012-07-15

    The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of {sup 18}F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). A comprehensive computer literature search of studies published through 30 June 2011 regarding {sup 18}F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of {sup 18}F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of {sup 18}F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of {sup 18}F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of {sup 18}F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of {sup 18}F-DOPA PET or PET/CT was found. A significant increase in sensitivity of {sup 18}F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. In patients with suspected PG {sup 18}F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. {sup 18}F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false

  11. Detection of occult bone metastases of lung cancer with fluorine-18 fluorodeoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Ramdave, Shankar; Berlangieri, Salvatore U.

    2004-01-01

    Accurate staging of cancer has a critical role in optimal patient management. Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) is superior to CT in the detection of local and distant metastases in patients with non-small cell lung cancer. Although Tc-99 m methylene diphosphonate (MDP) bone scanning is well established in the evaluation of bone metastases, there are conflicting reports on the use of FDG PET in the evaluation of skeletal metastases. We report on a patient with locally advanced lung carcinoma in whom FDG PET accurately identified previously unsuspected widespread asymptomatic bone metastases (bone scan and X-rays negative, confirmed on MRI). Assessment of glucose metabolism with FDG PET might represent a more powerful tool to detect bone metastases in lung cancer compared with conventional bone scans Copyright (2004) Blackwell Publishing Asia Pty Ltd

  12. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  13. PET/CT imaging in response evaluation of patients with small cell lung cancer

    DEFF Research Database (Denmark)

    Fischer, Barbara M; Mortensen, Jann; Langer, Seppo W

    2006-01-01

    UNLABELLED: There is an increasing amount of evidence on the usability of PET in response evaluation of non-small cell lung cancer. However, data on SCLC is scarce and mainly retrospective. This prospective study assesses the use of PET (positron emission tomography) and PET/CT in response...... evaluation of patients with small cell lung cancer (SCLC). METHODS: Assignment of early and final response was compared between PET, PET/CT, and CT in 20 patients with SCLC. Final response as assigned by CT (RECIST) served as reference. RESULTS: At response evaluation after one cycle of chemotherapy major...... by PET/CT is feasible, but it is uncertain whether it adds further information to evaluation by RECIST, thus further studies and standardization of methods are needed....

  14. Cowden syndrome detected by FDG PET/CT in an endometrial cancer patient

    International Nuclear Information System (INIS)

    Kang, Yun Hee; Lee, Hye Kyung; Park, Geon

    2016-01-01

    Cowden syndrome (CS) is a rare autosomal dominant disorder characterized by multiple hamartomas in various tissues and cancers (breast, thyroid, and endometrium). We report CS of the esophagus and gastrointestinal tract that was incidentally detected by positron emission tomography/computed tomography (PET/CT) at postoperative surveillance in an endometrial cancer patient. PET/CT showed mildly increased FDG uptake along the entire esophagus and stomach. Upper GI endoscopy and histologic examination revealed glycogenic acanthosis of the esophagus and several hundred gastric polyps. In our case, increased FDG uptake of the esophageal wall contributed to the diagnosis of CS

  15. Cowden syndrome detected by FDG PET/CT in an endometrial cancer patient

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Hee; Lee, Hye Kyung [Eulji University Hospital, Daejeon (Korea, Republic of); Park, Geon [Dept. of Radiology, The Catholic University of Korea, Daejeon Saint Mary' s Hospital, Daejeon (Korea, Republic of)

    2016-09-15

    Cowden syndrome (CS) is a rare autosomal dominant disorder characterized by multiple hamartomas in various tissues and cancers (breast, thyroid, and endometrium). We report CS of the esophagus and gastrointestinal tract that was incidentally detected by positron emission tomography/computed tomography (PET/CT) at postoperative surveillance in an endometrial cancer patient. PET/CT showed mildly increased FDG uptake along the entire esophagus and stomach. Upper GI endoscopy and histologic examination revealed glycogenic acanthosis of the esophagus and several hundred gastric polyps. In our case, increased FDG uptake of the esophageal wall contributed to the diagnosis of CS.

  16. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    International Nuclear Information System (INIS)

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration

  17. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    Science.gov (United States)

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration. PMID:24379541

  18. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  19. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  20. Recent advances in iterative reconstruction for clinical SPECT/PET and CT.

    Science.gov (United States)

    Hutton, Brian F

    2011-08-01

    Statistical iterative reconstruction is now widely used in clinical practice and has contributed to significant improvement in image quality in recent years. Although primarily used for reconstruction in emission tomography (both single photon emission computed tomography (SPECT) and positron emission tomography (PET)) there is increasing interest in also applying similar algorithms to x-ray computed tomography (CT). There is increasing complexity in the factors that are included in the reconstruction, a demonstration of the versatility of the approach. Research continues with exploration of methods for further improving reconstruction quality with effective correction for various sources of artefact.