WorldWideScience

Sample records for positive urine occult

  1. Heparin as a pharmacologic intervention to induce positive scintiscan in occult gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chaudhuri, T.K.; Brantly, M.

    1984-01-01

    The value of using heparin as a pharmacologic intervention to induce a positive scintiscan was studied in a patient with chronic occult gastrointestinal bleeding. When all standard diagnostic tests (upper and lower gastrointestinal series, upper and lower endoscopy, and conventional noninterventional Tc-99m RBC imaging) fail to detect and localize gastrointestinal bleeding in a patient who has definite clinical evidence (guaiac positive stool and dropping hemoglobin, hematocrit) of chronic occult gastrointestinal oozing, heparin may be used (with proper precaution) as a last resort to aid in the scintigraphic detection and localization of chronic occult gastrointestinal bleeding

  2. Amphetamine Positive Urine Toxicology Screen Secondary to Atomoxetine

    Directory of Open Access Journals (Sweden)

    Joshua L. Fenderson

    2013-01-01

    Full Text Available The aim of this paper is to report the first case of atomoxetine leading to false-positive urine drug screen. An otherwise healthy 27-year-old female with a history of attention deficit hyperactivity disorder (ADHD treated with atomoxetine had an acute onset tonic-clonic seizure. On arrival to the hospital, a urine toxicological drug screen with immunochemical cloned enzyme donor immunoassay (CEDIA was performed. Results were positive for amphetamines; however, the presence of these substances could not be confirmed with urine gas chromatography-mass spectrometry (GC-MS. She denied any illicit drug use, herbal medications, or supplements, and her other prescription medications have not been previously known to cause a false-positive result for amphetamines. While stimulant treatments for ADHD could certainly result in a positive result on urine screen for amphetamines, there have been no reports of false-positive results for amphetamines secondary to patients using atomoxetine. We implicate atomoxetine, and/or its metabolites, as a compound or compounds which may interfere with urine drug immunoassays leading to false-positive results for amphetamines CEDIA assays.

  3. Observing Tropospheric Water Vapor by Radio Occultation using the Global Positioning System

    Science.gov (United States)

    Kursinski, E. R.; Hajj, G. A.; Hardy, K. R.; Romans, L. J.; Schofield, J. T.

    1995-01-01

    Given the importance of water vapor to weather, climate and hydrology, global humidity observations from satellites are critical. At low latitudes, radio occultation observations of Earth's atmosphere using the Global Positioning System (GPS) satellites allow water vapor profiles to be retrieved with accuracies of 10 to 20% below 6 to 7 km altitude and approx. 5% or better within the boundary layer. GPS observations provide a unique combination of accuracy, vertical resolution (less than or equal to 1 km) and insensitivity to cloud and aerosol particles that is well suited to observations of the lower troposphere. These characteristics combined with the inherent stability of radio occultation observations make it an excellent candidate for the measurement of long term trends.

  4. Occult hepatitis B virus coinfection in HIV-positive African migrants to the UK: a point prevalence study.

    Science.gov (United States)

    Chadwick, D; Doyle, T; Ellis, S; Price, D; Abbas, I; Valappil, M; Geretti, A M

    2014-03-01

    Occult (surface antigen-negative/DNA-positive) hepatitis B virus (HBV) infection is common in areas of the world where HBV is endemic. The main objectives of this study were to determine the prevalence of occult HBV infection in HIV-infected African migrants to the UK and to determine factors associated with occult coinfection. This anonymized point-prevalence study identified Africans attending three HIV clinics, focussing on patients naïve to antiretroviral therapy (ART). Stored blood samples were tested for HBV DNA. Prevalence was calculated in the entire cohort, as well as in subpopulations. Risk factors for occult HBV coinfection were identified using logistic regression analysis. Among 335 HIV-positive African migrants, the prevalence of occult HBV coinfection was 4.5% [95% confidence interval (CI) 2.8-7.4%] overall, and 6.5% (95% CI 3.9-10.6%) and 0.8% (95% CI 0.2-4.6%) in ART-naïve and ART-experienced patients, respectively. Among ART-naïve anti-HBV core (anti-HBc)-positive patients, the prevalence was 16.4% (95% CI 8.3-25.6%). The strongest predictor of occult coinfection was anti-HBc positivity [odds ratio (OR) 7.4; 95% CI 2.0-27.6]. Median HBV DNA and ALT levels were 54 IU/mL [interquartile range (IQR) 33-513 IU/mL] and 22 U/L (IQR 13-27 U/L), respectively. Occult HBV coinfection remains under-diagnosed in African HIV-infected patients in the UK. Given the range of HBV DNA levels observed, further studies are warranted to determine its clinical significance and to guide screening strategies and ART selection in these patients. © 2013 British HIV Association.

  5. HBV vaccination of HCV-infected patients with occult HBV infection and anti-HBc-positive blood donors

    Directory of Open Access Journals (Sweden)

    J.S.F. Pereira

    2006-04-01

    Full Text Available Anti-HBc positivity is a frequent cause of donation rejection at blood banks. Hepatitis B virus (HBV infection may also occur in HBsAg-negative patients, a situation denoted occult infection. Similarly, very low levels of HBV-DNA have also been found in the sera of patients with chronic hepatitis C virus (HCV infection, even in the absence of serum HBsAg. Initially we searched for HBV-DNA in serum of 100 blood donors and 50 HCV-infected patients who were HBsAg negative/anti-HBc positive by nested-PCR and by an HBV monitor commercial test for HBV-DNA. Anti-HBs seroconversion rates were measured in 100 blood donors and in 22 patients with chronic HCV infection after HBV vaccination to determine if the HBV vaccination could eliminate an occult HBV infection in these individuals. Occult HBV infection was detected in proportionally fewer blood donors (6/100 = 6% than chronic hepatitis C patients (12/50 = 24% (P 0.05. All subjects who were HBV-DNA(+ before the first dose of HBV vaccine (D1, became HBV-DNA(- after D1, D2, and D3. Among 22 HCV-positive patients, 10 HBV-DNA(+ and 12 HBV-DNA(-, seroconversion was observed in 9/10 (90% HBV-DNA(+ and in 9/12 (75% HBV-DNA(- subjects (P > 0.05. The disappearance of HBV-DNA in the majority of vaccinated patients suggests that residual HBV can be eliminated in patients with occult infection.

  6. Endoscopic Follow-Up of Positive Fecal Occult Blood Testing in the Ontario FOBT Project

    Directory of Open Access Journals (Sweden)

    Lawrence Paszat

    2007-01-01

    Full Text Available BACKGROUND: The Ontario FOBT Project is a pilot study of fecal occult blood testing (FOBT for colorectal cancer screening conducted among age-eligible volunteers (50 to 75 years in 12 of 37 public health regions in Ontario.

  7. Positive urine cultures: A major cause of inappropriate antimicrobial use in hospitals?

    Science.gov (United States)

    Silver, Samuel A; Baillie, Laura; Simor, Andrew E

    2009-01-01

    Urine specimens are among the most common samples submitted for culture to microbiology laboratories. The objectives of the present study were to describe the indications for obtaining urine cultures in a cohort of hospitalized patients, and to determine the appropriateness of antimicrobial therapy in response to urine culture results. The study was performed at a teaching hospital with an adjoining long-term care facility from June 1 to July 31, 2006. The medical records of nonpregnant adult patients with and without bacteriuria were reviewed. A symptomatic urinary tract infection was defined as the presence of bacteriuria in a patient with fever or urinary symptoms; asymptomatic bacteriuria was defined as bacteriuria without urinary symptoms and no infection evident at another site. Medical records of 335 eligible patients (64% male; mean age 68 years) were reviewed, including all 137 with bacteriuria, and 198 with negative urine cultures. In total, 51% of the urine specimens were obtained from an indwelling urinary catheter, and 28% were voided urine samples. Confusion (57%) and fever (36%) were the most common indications noted for obtaining the urine cultures. Only 34 patients (25% of those with positive urine cultures) met the criteria for a symptomatic urinary tract infection; 67 (49%) had asymptomatic bacteriuria and 36 (26%) had infection at a nonurinary site. Of those with asymptomatic bacteriuria, 64% received antimicrobial therapy for a total of 347 days. Confused patients with asymptomatic bacteriuria were more likely to be treated than were bacteriuric patients without altered mental status (OR 1.8, 95% CI 1.2 to 4.1; P=0.03). Urine cultures are frequently obtained from hospitalizedpatients,evenintheabsenceofurinarysymptoms.Asymptomatic bacteriuria is often treated in these patients, and accounts for a substantial burden of inappropriate antimicrobial use in hospitals. Effective strategies to improve urine culture ordering and antimicrobial

  8. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  9. False-Positive TDxFLx urine Amphetamine/Metamphetamine II assay from Ofloxacin

    International Nuclear Information System (INIS)

    Nomier, Mahmoud A.; Al-Huseini, Hani K.

    2004-01-01

    Immunoassays are widely used in testing urine for illicit drugs. Ofloaxcin and a number of other quinolones were found to induce false-positive opiates (OP) urine immunoassays. This can result in misleading conclusions in the concept of drug abuse The aim of present study was to evaluate the effects of ofloxacin in theraputic doses on the induction of false-positive urine immunoassays for common drugs of abuse in healthy male volunteers. The study was conducted on 6 healthy male volunteers, aging between 35-45 years. Two doses of 400 mg ofloxacin each, were given orally to each volunteer at 12 hours interval and urine samples were collected before ofloaxcin administration and 5-7.5 hours after the second dose. Urine samples were subjected for OP, amphetamine/methamphetamine II (AM/MA II), cocaine and cannabinoids assays on TDxFLx analyzer. Ofloxacin produced significant increase (P cutoff) for AM/MA II assays, were found in all volunteers after ofloaxcin administration. The study recomends strongly the confirmation of positive urine immunoassay results for drugs of abuseby a more specific methodology e.g. gas chromatography/ mass spectroscopy (GC/MS). (author)

  10. Thermal Band Atmospheric Correction Using Atmospheric Profiles Derived from Global Positioning System Radio Occultation and the Atmospheric Infrared Sounder

    Science.gov (United States)

    Pagnutti, Mary; Holekamp, Kara; Stewart, Randy; Vaughan, Ronald D.

    2006-01-01

    This Rapid Prototyping Capability study explores the potential to use atmospheric profiles derived from GPS (Global Positioning System) radio occultation measurements and by AIRS (Atmospheric Infrared Sounder) onboard the Aqua satellite to improve surface temperature retrieval from remotely sensed thermal imagery. This study demonstrates an example of a cross-cutting decision support technology whereby NASA data or models are shown to improve a wide number of observation systems or models. The ability to use one data source to improve others will be critical to the GEOSS (Global Earth Observation System of Systems) where a large number of potentially useful systems will require auxiliary datasets as input for decision support. Atmospheric correction of thermal imagery decouples TOA radiance and separates surface emission from atmospheric emission and absorption. Surface temperature can then be estimated from the surface emission with knowledge of its emissivity. Traditionally, radiosonde sounders or atmospheric models based on radiosonde sounders, such as the NOAA (National Oceanic & Atmospheric Administration) ARL (Air Resources Laboratory) READY (Real-time Environmental Application and Display sYstem), provide the atmospheric profiles required to perform atmospheric correction. Unfortunately, these types of data are too spatially sparse and too infrequently taken. The advent of high accuracy, global coverage, atmospheric data using GPS radio occultation and AIRS may provide a new avenue for filling data input gaps. In this study, AIRS and GPS radio occultation derived atmospheric profiles from the German Aerospace Center CHAMP (CHAllenging Minisatellite Payload), the Argentinean Commission on Space Activities SAC-C (Satellite de Aplicaciones Cientificas-C), and the pair of NASA GRACE (Gravity Recovery and Climate Experiment) satellites are used as input data in atmospheric radiative transport modeling based on the MODTRAN (MODerate resolution atmospheric

  11. Importance of Urine Dipstick in Evaluation of Young Febrile Infants With Positive Urine Culture: A Spanish Pediatric Emergency Research Group Study.

    Science.gov (United States)

    Velasco, Roberto; Benito, Helvia; Mozun, Rebeca; Trujillo, Juan E; Merino, Pedro A; de la Torre, Mercedes; Gomez, Borja; Mintegi, Santiago

    2016-12-01

    Guidelines from the American Academy of Pediatrics define urinary tract infection (UTI) as the growth of greater than 50,000 ufc/mL of a single bacterium in a urine culture with a positive urine dipstick or with a urinalysis associated. Our objective was to evaluate the adequacy of this cutoff point for the diagnosis of UTI in young febrile infants. Subanalysis of a prospective multicenter study developed in RISeuP-SPERG Network between October 11 and September 13. To carry out the study, it was performed a comparison of analytical and microbiological characteristics of patients younger than 90 days with fever without focus, taking into account the results of urine dipstick and urine culture. Of a total of 3333 infants younger than 90 days with fever without focus which were included in the study, 538 were classified as UTI in accordance with American Academy of Pediatrics' guidelines. These patients were similar to those who had a positive urine dipstick and a urine culture yielding of 10,000 to 50,000 ufc/mL, and they were different from those who had a normal urine dipstick and a urine culture >50,000 ufc/mL, being focused on the isolated bacteria and blood biomarkers values. Forty-five invasive bacterial infections were diagnosed (5.9% of the 756 with a urine culture >10,000 ufc/mL). Half of the infants with a normal urine dipstick diagnosed with invasive bacterial infections were younger than 15 days. It might be inadequate to use a threshold of 50,000 cfu/mL to consider a urine culture as positive in young febrile infants given the fact that it would misdiagnose several UTIs.

  12. The Effect of Early Detection of Occult Brain Metastases in HER2-Positive Breast Cancer Patients on Survival and Cause of Death

    International Nuclear Information System (INIS)

    Niwinska, Anna; Tacikowska, Malgorzata; Murawska, Magdalena

    2010-01-01

    Purpose: The aim of the study is to evaluate disease-free survival, survival from the detection of brain metastases, overall survival, and cause of death in patients with occult brain metastases (Group I) vs. patients with symptomatic brain metastases (Group II). Methods and Materials: In 80 HER2-positive breast cancer patients, treated with trastuzumab and cytostatic agents for metastatic disease, magnetic resonance imaging screening of the brain was performed, and in 29 patients (36%) occult brain metastasis was detected (Group I). Whole-brain radiotherapy was delivered to Group I. This first group was compared with 52 patients who had symptomatic brain metastases (Group II) and was treated the same way, at the same clinic, during the same time period. Results: Median disease-free survival was 17 months in Group I and 19.9 months in Group II (p = 0.58). The median time interval between the dissemination of the disease and the detection of occult or symptomatic brain metastases was 9 and 15 months, respectively (p = 0.11). When the brain metastases were detected, the median survival was 9 and 8.78 months, respectively (p = 0.80). The median overall survival was 53 and 51 months, respectively (p = 0.94). In the group with occult brain metastases (Group I) 16% of patients died because of progression within the brain. In the group with symptomatic brain metastases (Group II) the rate of cerebral death was 48% (p = 0.009). Conclusions: Whole-brain radiotherapy of occult brain metastases in HER2-positive breast cancer patients with visceral dissemination produces a three-fold decrease in cerebral deaths but does not prolong survival.

  13. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  14. Investigation of occult hepatitis B virus infection in anti-hbc positive patients from a liver clinic.

    Science.gov (United States)

    Martinez, Maria Carmela; Kok, Chee Choy; Baleriola, Cristina; Robertson, Peter; Rawlinson, William D

    2015-01-01

    Occult hepatitis B infection (OBI) is manifested by presence of very low levels (Hepatitis B viral DNA (HBV DNA) in the blood and the liver while exhibiting undetectable HBV surface antigen (HBsAg). The molecular mechanisms underlying this occurrence are still not completely understood. This study investigated the prevalence of OBI in a high-risk Australian population and compared the HBV S gene sequences of our cohort with reference sequences. Serum from HBV DNA positive, HBsAg negative, and hepatitis B core antibody (anti-HBc) positive patients (study cohort) were obtained from samples tested at SEALS Serology Laboratory using the Abbott Architect, as part of screening and diagnostic testing. From a total of 228,108 samples reviewed, 1,451 patients were tested for all three OBI markers. Only 10 patients (0.69%) out of the 1,451 patients were found to fit the selection criteria for OBI. Sequence analysis of the HBV S gene from 5 suspected OBI infected patients showed increased sequence variability in the 'a' epitope of the major hydrophilic region compared to reference sequences. In addition, a total of eight consistent nucleotide substitutions resulting in seven amino acid changes were observed, and three patients had truncated S gene sequence. These mutations appeared to be stable and may result in alterations in HBsAg conformation. These may negatively impact the affinity of hepatitis B surface antibody (anti-HBs) and may explain the false negative results in serological HBV diagnosis. These changes may also enable the virus to persist in the liver by evading immune surveillance. Further studies on a bigger cohort are required to determine whether these amino acid variations have been acquired in the process of immune escape and serve as markers of OBI.

  15. Positioning irrigation of contrast cystography for diagnosis of occult vesicoureteric reflux: association with technetium-99m dimercaptosuccinic acid scans.

    Science.gov (United States)

    Berger, Christoph; Becker, Tanja; Koen, Mark; Zeino, Mazen; Fitz, Friedrich; Beheshti, Mohsen; Wolf-Kohlmeier, Iris; Haim, Silke; Riccabona, Marcus

    2013-12-01

    Positioning irrigation of contrast (PIC) cystography identifies occult or PIC vesicoureteral reflux (PIC-VUR) in children with recurrent febrile urinary tract infections (UTI) but no vesicoureteric reflux (VUR) on standard voiding cystourethrogram (VCUG). We sought to identify the relationship between PIC-VUR and renal scarring in technetium-99m dimercaptosuccinic acid (DMSA) scans. We retrospectively analysed PIC cystograms and DMSA scans for 154 kidneys in 81 children (65 girls; 16 boys; median age, 4.7 years; range, 0.9-15.2). Renal scarring was graded on a scale of 0-3. DMSA scans were pathologic in 66 patients (81%). Children had experienced mean 3.8 febrile UTI (range 1-25). Forty-seven (58%) children had a history of reflux, including 15 (19%) with previous anti-reflux operations. Indications for PIC cystography were recurrence of febrile UTI after either bilateral negative VCUG (66 children) or unilateral VUR (15 children) with contralateral/bilateral scarring or reflux that had changed sides in subsequent VCUGs. PIC-VUR was bilateral in 63, unilateral in 12, and absent in 6 children. Statistically significant associations between PIC-VUR grade and severity of renal scarring were identified in inter-individual (n = 77, p = 0.017) and intra-individual (refluxing vs. nonrefluxing kidney; n = 12, p = 0.008) analyses. After excluding patients with history of VUR, statistical significance was maintained in inter-individual analysis (n = 49; p = 0.018). The data suggest an association between PIC-VUR and severity of renal scarring, and legitimise the use of PIC cystography in children with renal scarring due to recurrent febrile UTI but negative findings on VCUG. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  16. USING A MULTIFACETED APPROACH TO IMPROVE THE FOLLOW-UP OF POSITIVE FECAL OCCULT BLOOD TEST RESULTS

    Science.gov (United States)

    Singh, Hardeep; Kadiyala, Himabindu; Bhagwath, Gayathri; Shethia, Anila; El-Serag, Hashem; Walder, Annette; Velez, Maria; Petersen, Laura A.

    2010-01-01

    Background Inadequate follow-up of abnormal fecal occult blood test (FOBT) results occurs in several types of practice settings. Our institution implemented multifaceted quality improvement (QI) activities in 2004–2005 to improve follow-up of FOBT positive results. Activities addressed pre-colonoscopy referral processes and system-level factors such as electronic communication and provider education and feedback. We evaluated their effects on timeliness and appropriateness of positive FOBT follow-up and identified factors that affect colonoscopy performance. Methods Retrospective electronic medical record (EMR) review was used to determine outcomes pre- and post-QI activities in a multi-specialty ambulatory clinic of a tertiary care Veterans Affairs facility and its affiliated satellite clinics. From 1869 FOBT positive cases, 800 were randomly selected from time periods before and after QI activities. Two reviewers used a pretested standardized data collection form to determine whether colonoscopy was appropriate or indicated based on pre-determined criteria and if so, the timeliness of colonoscopy referral and performance pre- and post-QI activities. Results In cases where a colonoscopy was indicated, the proportion of patients who received a timely colonoscopy referral and performance were significantly higher post implementation (60.5% vs. 31.7%, pperformance (6 vs. 19 days pperformance of an indicated colonoscopy included performance of a non-colonoscopy procedure such as barium enema or flexible sigmoidoscopy (OR=16.9; 95% CI 1.9–145.1), patient non-adherence (OR=33.9; 95% CI 17.3–66.6), not providing an appropriate provisional diagnosis on the consultation (OR= 17.9; 95% CI 11.3–28.1) and gastroenterology service not rescheduling colonoscopies after an initial cancellation (OR= 11.0; 95% CI 5.1–23.7) Conclusions Multifaceted QI activities improved rates of timely colonoscopy referral and performance in an EMR system. However, colonoscopy was not

  17. Photometry and position observations of Saturnian satellites during their mutual eclipses and occultations in 1995 performed at the Observatories in Russia and Kazakhstan

    Science.gov (United States)

    Emelianov, N. V.; Irsmambetova, T. R.; Kiseleva, T. P.; Tejfel, V. G.; Vashkovjak, S. N.; Glushkova, E. A.; Kornilov, V. G.; Charitonova, G. A.

    1999-10-01

    Photometry of mutual eclipses and occultations of planetary satellites is a powerful technique to explore these bodies. Observations of these rare events are a source of much precise information. In 1995 the Celestial Mechanics Department of the Sternberg Astronomical Institute (SAI) has organized the observations of mutual eclipses and occultations of Saturnian satellites on a number of observatories of the Commonwealth of Independent States (CIS) -- the former Soviet Union (FSU). The ephemerides of satellites and their observing conditions have been computed beforehand and mailed these data to many observatories of CIS. The Crimean laboratory (CL) of the Sternberg Astronomical Institute, two observatories of the Fesenkov Astrophysical Institute of the Academy of Sciences of the Republic of Kazakhstan (FAI AS RK) in Almaty, and the Main Astronomical Observatory of Russian Academy of Sciences (MAO RAS) in Pulkovo took part in observations. A photoelectric photometer was used in CL of SAI, a CCD was employed to secure satellite images in FAI AS RK, and both CCD and photographic plates were used in MAO RAS. As a result of this observing campaign, photometric data and light curves were obtained for three mutual eclipses and occultations of Saturnian satellites. A number of position observations made allowed us to measure relative coordinates of satellites. Astrometric information has already been derived from photometric data. The mutual apparent positions of satellites were calculated with an accuracy of 0farcs 002 - 0farcs 003. In this paper observations are described and the parameters characterizing the observed phenomena are given. The results of observations are available in electronic form. This work supported by the Russian Foundation for Basic Research, projects Nos. 95-02-05042, 97-02-16551. Results of observations available in electronic form at CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/Abstract.html

  18. Positive association between concentration of phthalate metabolites in urine and microparticles in adolescents and young adults.

    Science.gov (United States)

    Lin, Chien-Yu; Hsieh, Chia-Jung; Lo, Shyh-Chyi; Chen, Pau-Chung; Torng, Pao-Ling; Hu, Anren; Sung, Fung-Chang; Su, Ta-Chen

    2016-01-01

    Di-(2-ethylhexyl) phthalate (DEHP) has been used worldwide in various products for many years. In vitro studies have shown that exposure to DEHP and its metabolite mono(2-ethylhexyl) phthalate (MEHP) induces endothelial cell apoptosis. Moreover, exposure to DEHP had been linked to cardiovascular risk factors and cardiovascular diseases in epidemiological studies. Circulating microparticles have been known to be indicators of vascular injury. However, whether DEHP or its metabolites are independently associated with microparticles in humans remains unknown. From 2006 to 2008, we recruited 793 subjects (12-30years) from a population-based sample to participate in this cardiovascular disease prevention examination. Each participant was subjected to interviews and biological sample collection to determine the relationship between concentrations of DEHP metabolites MEHP, mono(ethyl-5-hydroxyhexyl) phthalate, and mono(2-ethly-5-oxoheyl) phthalate in urine and concentrations of endothelial microparticles (CD62E and CD31+/CD42a-), platelet microparticles (CD62P and CD31+/CD42a+), and CD14 in serum. Multiple linear regression analysis revealed that an ln-unit increase in MEHP concentration in urine was positively associated with an increase in serum microparticle counts/μL of 0.132 (±0.016) in CD31+/CD42a- (endothelial apoptosis marker), 0.117 (±0.023) in CD31+/CD42a+ (platelet apoptosis marker), and 0.026 (±0.007) in CD14 (monocyte, macrophage, and neutrophil activation marker). There was no association between DEHP metabolite concentration and CD62E or CD62P. In conclusion, a higher MEHP concentration in urine was associated with an increase in endothelial and platelet microparticles in this cohort of adolescents and young adults. Further studies are warranted to clarify the causal relationship between exposure to DEHP and atherosclerosis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Urine Osmolality in Treatment-naïve HIV-positive Subjects in ...

    African Journals Online (AJOL)

    2017-03-01

    Mar 1, 2017 ... a significant association between urine osmolality and body mass index (BMI), creatinine clearance, as well as serum .... approved by the Ethics Research Committee of the hospital. With the help of a questionnaire, .... SD=standard deviation, SUOsm=spot urine osmolality,. 24UOsm=24-h urine osmolality, ...

  20. Positive Urine Cultures: A Major Cause of Inappropriate Antimicrobial Use in Hospitals?

    Directory of Open Access Journals (Sweden)

    Samuel A Silver

    2009-01-01

    Full Text Available INTRODUCTION: Urine specimens are among the most common samples submitted for culture to microbiology laboratories. The objectives of the present study were to describe the indications for obtaining urine cultures in a cohort of hospitalized patients, and to determine the appropriateness of antimicrobial therapy in response to urine culture results.

  1. Urine osmolality in treatment-naïve HIV-positive subjects in ...

    African Journals Online (AJOL)

    Urine osmolality is not commonly evaluated in routine clinical practice and in human immunodeficiency virus (HIV) subjects. The factors that influence urine osmolality have not been completely identified. The aim of this study was to evaluate urine osmolality in treatment‑naïve HIV subjects and to identify the factors that may ...

  2. Antimicrobial Resistance Patterns in Women with Positive Urine Culture: Does Menopausal Status Make a Significant Difference?

    Directory of Open Access Journals (Sweden)

    Pawel Miotla

    2017-01-01

    Full Text Available Aim. Urinary tract infection (UTI is considered one of the most common bacterial infections in women. The aim of this study was to investigate the types of uropathogens present, as well as the degree of antimicrobial drug resistance seen among premenopausal (n=2748 and postmenopausal (n=1705 women with uncomplicated UTI. Methods. Urinary samples (n=4453 collected from women with UTI were analyzed in terms of uropathogens present. These were considered as positive if bacterial growth was ≥105 colony forming units (CFUs/mL. Susceptibility and resistance testing for commonly used antibiotics was subsequently assessed. Results. The most common uropathogens cultured from urine samples were Escherichia coli (65.5%, followed by Enterococcus faecalis (12.2%, Klebsiella pneumoniae (4.7%, and Proteus mirabilis (4.2%. The resistance to ampicillin exceeded 40%, independently of menopausal status. Of note, resistance to ciprofloxacin exceeded 25% among postmenopausal patients. Moreover, resistance of all uropathogens to commonly used antimicrobials was significantly higher in postmenopausal women. Conclusion. Due to the high resistance rate, ampicillin, ciprofloxacin, and the trimethoprim/sulfamethoxazole combination should be avoided in treating postmenopausal women affected by UTI without being indicated by initial urine culture report. Finally, cephalexin and cefuroxime are promising alternatives as initial treatment in postmenopausal women.

  3. An observation on positive rate of HBsAg in the urine of patients suffering from positive serum HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Peixun, Lin; Mingzheng, Zeng; Xiaoling, Chai [Wuhan Eighth Municipal Hospital, HB (China). Dept. of Laboratory

    1989-08-01

    In 1983, the Virus Research Office of the Shanxi Research Insitute of Preventive Medicine found out the granules of hepatitis B virus from the urine of patients and proved that this kind of virus can be spread through the urine. With the help of self-developed method of radio immunoelectrophoresis, our research office has purified and concentrated the urine of the patients suffering from positive serum HBsAg (hepatitis B surface antigen). Among them 25 are male, and another 25 are female. The result shows that the positive rate of HBsAg accounts for 80%. This is of important significance to the care of urine specimens, the protection of experimentalists and the development of clinical medicine.

  4. When to perform urine cultures in respiratory syncytial virus-positive febrile older infants?

    Science.gov (United States)

    Kaluarachchi, Dinushan; Kaldas, Virginia; Erickson, Evelyn; Nunez, Randolph; Mendez, Magda

    2014-09-01

    Respiratory syncytial virus (RSV) infections are associated with clinically significant rate of urinary tract infections (UTIs) in young infants. Previous research investigating RSV infections and UTIs has been performed mainly in infants younger than 2 to 3 months and has not focused on the risk of UTI in infants 3 to 12 months. This study aimed to assess the rate of UTIs in febrile RSV-positive older infants admitted as inpatients and identify predictors of UTI in febrile RSV-positive older infants. This is a retrospective comparative study of febrile RSV-positive infants 0 to 12 months of age admitted to the inpatient pediatric unit of Lincoln Medical and Mental Health Center, Bronx, from September through April 2006 to 2012. Infants 3 to 12 months were considered the cases, and infants 0 to 3 months were the comparative group. The rate of UTIs between the 2 groups was compared. Univariate tests and multiple logistic regression were used to identify demographic/clinical factors associated with UTI in febrile RSV-positive older infants. A total of 414 RSV-positive febrile infants were enrolled including 297 infants 3 to 12 months of age. The rate of UTI in older infants was 6.1% compared with 6.8% in infants younger than 3 months. Positive urinalysis finding was an independent predictor of UTI (P = 0.003) in older infants. All 11 boys with UTI were uncircumcised, and none of the 51 circumcised boys had UTI. Demographic (race, sex, and age) and clinical factors (temperature, white blood cell count, and absolute neutrophil count) were not associated with UTI. Febrile older infants who are RSV positive have a clinically significant rate of UTIs. It seems prudent to examine the urine of these older infants. Positive urinalysis finding was a predictive factor of UTI. Circumcised boys are at a decreased risk of UTI, compared with uncircumcised boys.

  5. Detection of radiographically occult-ankle fractures. Positive predictive value of post-traumatic soft-tissue swelling

    International Nuclear Information System (INIS)

    Kumar, M.; Caruana, E.

    2000-01-01

    The objective of this study was to assess the value of soft-tissue swelling on plain radiographs as a predictor of radiographically occult fracture, after acute ankle injury (trauma). Patients with acute ankle trauma and plain radiographic evidence of soft-tissue swelling were included in this study. Patients were excluded if ankle trauma was sustained more than 48 hours previously or if fracture was visible on plain radiographs. All subjects (n=25) underwent computed tomography (CT) of the ankle in sagittal and coronal planes. Size of soft-tissue swelling was measured from initial Antero-posterior (AP) radiographs. The subjects in the study were placed into two groups according to whether a fracture was identified on CT or not. The results identified that those subjects without a fracture demonstrated by CT, had a soft-tissue swelling of less than 12.6 mm, while those with over 17.1mm swelling, showed a fracture on CT. Twelve patients (48 per cent) had radiographically occult fractures identified with CT. Fracture sites included: Talus/Talar Dome (n=9), posterior or lateral malleolos (n=2), distal tibia/fibula (n=1). CT detected significant soft-tissue injuries in six patients (24 per cent), composed of damaged anterior talo-fibular ligament (n=4), torn flexor tendons (n=1), and damaged fibular calcaneal ligament (n=1). One patient also showed gas in the talar dome. This study concludes that presence of a large soft-tissue swelling on plain radiographs after acute ankle trauma suggests an underlying fracture. A soft-tissue swelling of >15 mm is a reasonable threshold to prompt further imaging. Helical computed tomography provides good visualisation of subtle bone injuries and may detect clinically important soft-tissue injuries. While the study has a small sample, there is clear evidence that there is a trend worth investigating. Future research will seek to investigate a larger sample. Copyright (1999) Australian Institute of Radiography

  6. Inhalation but not transdermal resorption of hand sanitizer ethanol causes positive ethyl glucuronide findings in urine.

    Science.gov (United States)

    Arndt, Torsten; Schröfel, Stefanie; Güssregen, Brunhilde; Stemmerich, Karsten

    2014-04-01

    Ethyl glucuronide (EtG) in urine is considered a specific marker of recent ethanol consumption. There is an ongoing debate about whether inhalation or transdermal resorption of sanitizer ethanol is the underlying cause for positive EtG findings after hand disinfection. Desderman(®) pure (Schülke & Mayr GmbH, Norderstedt) with 78.2g 96% (v/v) ethanol/100g and approx. 10% 2-propanol was used for multiple hand disinfection without and under an exhauster. Simulating a common working day in a clinic, 5 co-workers of our lab used the sanitizer 32 fold within 8h and 2 persons were merely exposed to the sanitizer vapor but without any dermal sanitizer contact. Any additional ethanol intake or exposition was reliably excluded. Spot urine was collected at baseline, after 1, 2, 4, 6 … 14, and finally 24h after the first sanitizer use. A validated LC-MS/MS was used for MRM and MS(3) of EtG and qualitative analyses of ethyl sulfate and 2-propyl glucuronide. Multiple hand disinfection caused positive EtG findings of up to 2.1mg/L or 1.7mg/g creatinine in 4 out of 5 test persons and even of 0.6mg/L or 0.8mg/g for 2 controls which were merely exposed to the sanitizer vapor but without any sanitizer contact. EtG results between the clinical (0.5mg/g) and the forensic (0.1mg/g) cut-off were obtained even 6h after the last sanitizer exposition. An exhauster prevented the sanitizer vapor inhalation and reduced the EtG excretion to mostly below the detection limit of 0.02mg/g. The maximum value was 0.09mg/g. Ethyl sulfate and 2-propyl glucuronide (2-PpG) were detectable only in the EtG positive samples. 2-PpG is a metabolite of 2-propanol, which is quite frequently used in disinfectants. Thus, the detection of this substance can be used in cases of odd EtG results as an indicator of (unintended) sanitizer exposition. Ethanol from hand sanitizers is predominantly incorporated by the respiratory tract but not via the skin. It can cause a distinct ethyl glucuronide excretion and thus

  7. Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections.

    Science.gov (United States)

    Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem

    2014-08-01

    The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.

  8. Urine Osmolality in Treatment-naïve HIV-positive Subjects in ...

    African Journals Online (AJOL)

    2017-03-01

    Mar 1, 2017 ... commonly evaluated in routine clinical practice and in human ... the variables and urine osmolality and the strength of variables to ... function, and weight were common in treatment-naïve HIV subjects who had ... Nigeria, underweight and obesity, urine osmolality ..... associated with a salt-losing syndrome.

  9. Characteristics of atmospheric gravity waves observed using the MU (Middle and Upper atmosphere) radar and GPS (Global Positioning System) radio occultation.

    Science.gov (United States)

    Tsuda, Toshitaka

    2014-01-01

    The wind velocity and temperature profiles observed in the middle atmosphere (altitude: 10-100 km) show perturbations resulting from superposition of various atmospheric waves, including atmospheric gravity waves. Atmospheric gravity waves are known to play an important role in determining the general circulation in the middle atmosphere by dynamical stresses caused by gravity wave breaking. In this paper, we summarize the characteristics of atmospheric gravity waves observed using the middle and upper atmosphere (MU) radar in Japan, as well as novel satellite data obtained from global positioning system radio occultation (GPS RO) measurements. In particular, we focus on the behavior of gravity waves in the mesosphere (50-90 km), where considerable gravity wave attenuation occurs. We also report on the global distribution of gravity wave activity in the stratosphere (10-50 km), highlighting various excitation mechanisms such as orographic effects, convection in the tropics, meteorological disturbances, the subtropical jet and the polar night jet.

  10. Boundary diffraction wave integrals for diffraction modeling of external occulters

    OpenAIRE

    Cady, E.

    2012-01-01

    An occulter is a large diffracting screen which may be flown in conjunction with a telescope to image extrasolar planets. The edge is shaped to minimize the diffracted light in a region beyond the occulter, and a telescope may be placed in this dark shadow to view an extrasolar system with the starlight removed. Errors in position, orientation, and shape of the occulter will diffract additional light into this region, and a challenge of modeling an occulter system is to accurately and quickly...

  11. Sensitivity and specificity of CT colonography for the detection of colonic neoplasia after positive faecal occult blood testing: systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Pendse, Douglas A.; Taylor, Stuart A. [University College London, Centre for Medical Imaging, London (United Kingdom); Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College London, University College Hospital, Centre for Medical Imaging, Podium Level 2, London (United Kingdom); Mallett, Susan [University of Oxford, Department of Primary Care Health Sciences, Oxford (United Kingdom)

    2014-05-15

    CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. (orig.)

  12. Sensitivity and specificity of CT colonography for the detection of colonic neoplasia after positive faecal occult blood testing: systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Plumb, Andrew A.; Pendse, Douglas A.; Taylor, Stuart A.; Halligan, Steve; Mallett, Susan

    2014-01-01

    CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. (orig.)

  13. A trend analysis of laboratory positive propoxyphene workplace urine drug screens before and after the product recall.

    Science.gov (United States)

    Price, James

    2015-01-01

    Propoxyphene was withdrawn from the US market in November 2010. This drug is still tested for in the workplace as part of expanded panel nonregulated testing. A convenience sample of urine specimens (n = 7838) were provided by workers from various industries. The percentage of positive specimens with 95% confidence intervals was calculated for each year of the study. Logistic regression was used to assess the impact of the year upon the propoxyphene result. The prevalence of positive propoxyphene tests was much higher before the product's withdrawal from the market. Logistic regression provided evidence of a decreasing linear trend (P < 0.000; β = -0.71). The odds ratio signifies that for every additional year the urine specimens were 0.49 times less likely to be positive for propoxyphene. This favors the determination that the change in propoxyphene positive drug test over the years is not by chance. The conclusion supports no longer performing nonregulated workplace propoxyphene urine drug testing for this population.

  14. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  15. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    Science.gov (United States)

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Concurrent colonic mucosa-associated lymphoid tissue lymphoma and adenoma diagnosed after a positive fecal occult blood test: a case report.

    Science.gov (United States)

    Lin, Pei-Chiang; Chen, Jinn-Shiun; Deng, Po; Wang, Chih-Wei; Huang, Chiung-Huei; Tang, Reiping; Chiang, Jy-Ming; Yeh, Chien-Yuh; Hsieh, Pao-Shiu; Tsai, Wen-Sy; Chiang, Sum-Fu

    2016-01-27

    Colonic lymphoma is an uncommon presentation of extranodal lymphoma. Colonic mucosa-associated lymphoid tissue lymphoma is a different entity from gastric mucosa-associated lymphoid tissue lymphoma, and very rare. The presentation and management of colonic mucosa-associated lymphoid tissue are highly variable in the literature. We report the case of a 59-year-old Taiwanese man who underwent a colonoscopy after a positive test for fecal occult blood. His past history included hypertension and hyperthyroidism. The colonoscopy revealed an adenomatous polyp and mucosa-associated lymphoid tissue lymphoma. We successfully performed a polypectomy and endoscopic mucosal resection. The lymphoma was staged according to the Ann Arbor system modified by Musshoff as E-I. Our patient showed no lymphoma recurrence over a 3-year follow-up. Endoscopic mucosal resection for colonic mucosa-associated lymphoid tissue lymphoma without disseminated disease may be feasible. We successfully used colonoscopic treatment without adjuvant therapy to treat early-stage pathogen-free colonic mucosa-associated lymphoid tissue lymphoma.

  17. Quantitation of HBV cccDNA in anti-HBc-positive liver donors by droplet digital PCR: a new tool to detect occult infection.

    Science.gov (United States)

    Caviglia, Gian Paolo; Abate, Maria Lorena; Tandoi, Francesco; Ciancio, Alessia; Amoroso, Antonio; Salizzoni, Mauro; Saracco, Giorgio Maria; Rizzetto, Mario; Romagnoli, Renato; Smedile, Antonina

    2018-04-02

    The accurate diagnosis of occult HBV infection (OBI) requires the demonstration of HBV DNA in liver biopsies of HBsAg-negative subjects. However, in clinical practice a latent OBI is deduced by the finding of the antibody to the HB-core antigen (anti-HBc). We investigated the true prevalence of OBI and the molecular features of intrahepatic HBV in anti-HBc-positive subjects. The livers of 100 transplant donors (median age 68.2 years; 64 males, 36 females) positive for anti-HBc at standard serologic testing, were examined for total HBV DNA by nested-PCR and for the HBV covalently closed circular DNA (HBV cccDNA) with an in-house droplet digital PCR assay (ddPCR) (Linearity: R 2 = 0.9998; lower limit of quantitation and detection of 2.4 and 0.8 copies/10 5 cells, respectively). A true OBI status was found in 52% (52/100) of the subjects and cccDNA was found in 52% (27/52) of the OBI-positive, with a median 13 copies/10 5 cells (95% confidence interval 5-25). Using an assay specific for anti-HBc of IgG class, the median antibody level was significantly higher in HBV cccDNA-positive than negative donors (5.7 [3.6-9.7] vs. 17.0 [7.0-39.2] COI, p = 0.007). By multivariate analysis, an anti-HBc IgG value above a 4.4 cut-off index (COI) was associated with the finding of intrahepatic HBV cccDNA (OR = 8.516, p = 0.009); a lower value ruled out its presence with a negative predictive value of 94.6%. With a new in-house ddPCR-based method, intrahepatic HBV cccDNA was detectable in quantifiable levels in about half of the OBI cases examined. The titer of anti-HBc IgG may be a useful surrogate to predict the risk of OBI reactivation in immunosuppressed patients. The covalently closed circular DNA (cccDNA) form of the Hepatitis B virus (HBV) sustains the persistence of the virus even after decades of resolution of the florid infection (Occult HBV infection=OBI). In the present study we developed an highly sensitive method based on droplet digital PCR technology for the detection

  18. Black Urine

    Directory of Open Access Journals (Sweden)

    Rahim Vakili

    2016-06-01

    Full Text Available A 2-year-old boy was born at term of healthy, non-consanguineous Iranian parents. His mother attended in the clinic with the history of sometimes discoloration of diapers after passing urine. She noticed that first at the age of one month with intensified in recent months. His Physical examination and growth parameters were normal. His mother denied taking any medication (sorbitol, nitrofurantoin, metronidazole, methocarbamol, sena and methyldopa (5. Qualitative urine examination showed dark black discoloration. By this history, alkaptonuria was the most clinical suspicious. A 24-hour-urine sample was collected and sent for quantitative measurements. The urine sample was highly positive for homogentisic acid and negative for porphyrin metabolites.

  19. Approach to a Positive Urine Culture in a Patient Without Urinary Symptoms

    Science.gov (United States)

    Trautner, Barbara W.; Grigoryan, Larissa

    2013-01-01

    Asymptomatic bacteriuria (ASB) is a condition in which bacteria are present in a noncontaminated urine sample collected from a patient without signs or symptoms related to the urinary tract. ASB must be distinguished from symptomatic UTI by the absence of signs and symptoms compatible with UTI or by clinical determination that a nonurinary etiology accounts for the patient's symptoms. ABU is a very common condition that is often treated unnecessarily with antibiotics. Pregnant women and persons undergoing urologic procedures expected to cause mucosal bleeding are the only two groups with convincing evidence that screening for and treating ASB is beneficial. Randomized, controlled trials of ASB screening and/or treatment have established the lack of efficacy in premenopausal adult women, diabetic women, patients with spinal cord injury, catheterized patients, older adults living in the community, and elderly institutionalized adults. The overall purpose of this review is to promote an awareness of ASB as a distinct condition from UTI and to empower clinicians to withhold antibiotics in situations in which antimicrobial treatment of bacteriuria is not indicated. PMID:24484572

  20. A centrally generated primary care physician audit report does not improve colonoscopy uptake after a positive result on a fecal occult blood test in Ontario's ColonCancerCheck program.

    Science.gov (United States)

    Stock, D; Rabeneck, L; Baxter, N N; Paszat, L F; Sutradhar, R; Yun, L; Tinmouth, J

    2017-02-01

    Timely follow-up of fecal occult blood screening with colonoscopy is essential for achieving colorectal cancer mortality reduction. In the present study, we evaluated the effectiveness of centrally generated, physician-targeted audit and feedback to improve colonoscopy uptake after a positive fecal occult blood test (fobt) result within Ontario's population-wide ColonCancerCheck Program. This prospective cohort study used data sets from Ontario's ColonCancerCheck Program (2008-2011) that were linked to provincial administrative health databases. Cox proportional hazards regression was used to estimate the effect of centralized, physician-targeted audit and feedback on colonoscopy uptake in an Ontario-wide fobt-positive cohort. A mailed physician audit and feedback report identifying individuals outstanding for colonoscopy for 3 or more months after a positive fobt result did not increase the likelihood of colonoscopy uptake (hazard ratio: 0.95; 95% confidence interval: 0.79 to 1.13). Duration of positive fobt status was strongly inversely associated with the hazard of follow-up colonoscopy ( p for linear trend: audit and feedback reports does not improve colonoscopy uptake for screening participants with a positive fobt result outstanding for 3 or more months. Mailed physician-targeted screening audit and feedback reports alone are unlikely to improve compliance with follow-up colonoscopy in Ontario. Other interventions such as physician audits or automatic referrals, demonstrated to be effective in other jurisdictions, might be warranted.

  1. Measurement of stellar occultations

    Science.gov (United States)

    Eberle, Andreas

    2008-09-01

    Whenever an asteroid occults a star, we have the opportunity to study that asteroid in great detail. As frequently shown in the past, amateur astronomers1 have the necessary equipment to measure such events successfully2. Combined with the dense net of amateur observatories and online coordination tools3 for movable stations, they can create fine grids to detect even small bodies. The analysis of these events gives us the possibility to receive high precision astrometry data, to determine the asteroids size and shape (and therefore its albedo), and even to collect information on the star itself.4 While usually a set of several light curves is required to do so, a single recording5 of (10734) Wieck's occultation of HIP 22157 on 2008 Feb 08 was sufficient to retrieve the necessary data6. 1 Observation campaigns are organized by the International Occultation Timing Association (IOTA), http://www.iota-es.de/ 2 for results see e.g. euraster.net by E. Frappa, http://www.euraster.net/ 3 Occult Watcher by H. Pavlov, http://www.hristopavlov.net/OccultWatcher/OccultWatcher.html 4 see K. Miyashita's analysis of the observation of the occultation of TYC 1886-01206-1 by Kalliope and Linus, http://www005.upp.so-net.ne.jp/k miyash/occ02/kalliope/doublestar en.html 5 recording obtained by H. Michels, MPC Station Code 240 6 using Limovie by K. Miyashita

  2. Urine-Based Nested PCR for the Diagnosis of Mycobacterium tuberculosis: A Comparative Study Between HIV-Positive and HIV-Negative Patients.

    Science.gov (United States)

    Jamshidi Makiani, Mahin; Davoodian, Parivash; Baghershiroodi, Mahnaz; Nejatizadeh, Abdol Azim; Fakkhar, Farideh; Zangeneh, Mehrangiz; Jahangiri, Nadia

    2016-08-01

    While tuberculosis (TB) can be diagnosed by microscopy and culture, the sensitivity of Ziehl-Neelsen staining is variable and culture results require 4 - 8 weeks to be determined. Polymerase chain reaction (PCR) and its modifications, including nested PCR, might be promising methods for the rapid diagnosis of TB. This study aimed to evaluate the performance of nested PCR on urine samples of human immunodeficiency virus (HIV)-positive and -negative patients with different manifestations of clinical TB. In a prospective study, three early-morning urine samples from 100 patients with pulmonary TB (PTB) or extrapulmonary TB (EPTB) were evaluated using a molecular target with insertion element IS6110, specific to the Mycobacterium tuberculosis genome, and nested PCR was performed. The results were analyzed with SPSS version 22. A total of 100 patients, including 74 (74%) with PTB and 26 (26%) with EPTB, were enrolled. Positive smears were seen in 38 patients (38%). Lymph nodes were the most commonly involved organ in 14 of the 26 (53.8%) EPTB patients (13.5%). Seven (23.1%) of the EPTB patients were HIV-positive. Urine PCR was positive in only 28 patients (28%). Seven HIV-positive patients with PTB showed positive urine PCR results. Moreover, PCR results were positive in only one of the seven HIV-positive subjects with EPTB. Positive PCR results were found in 20 of the 73 HIV-negative patients (27.4%) and in 8 of the 27 HIV-positive patients (29.6%). Therefore, there was no significant difference between the HIV-negative and HIV-positive patients for urine PCR (sensitivity 29.6%, specificity 72.6%; positive and negative predictive values 28% and 72%, respectively; P = 0.138). Nested PCR showed the same sensitivity in HIV-positive and HIV-negative patients. It can be applied as a rapid technique for the diagnosis of TB.

  3. Bilirubin - urine

    Science.gov (United States)

    Conjugated bilirubin - urine; Direct bilirubin - urine ... Bilirubin is not normally found in the urine. ... Increased levels of bilirubin in the urine may be due to: Biliary tract disease Cirrhosis Gallstones in the biliary tract Hepatitis Liver disease ...

  4. Urine Cytology

    Science.gov (United States)

    Urine cytology Overview Urine cytology is a test to look for abnormal cells in your urine. It's used with other tests and procedures to diagnose ... bladder cancer. Your doctor might recommend a urine cytology test if you have blood in your urine ( ...

  5. Oligometastasis as a predictor for occult disease.

    Science.gov (United States)

    Kendal, Wayne S

    2014-05-01

    Oligometastasis can be defined as a state of limited metastases that is potentially amenable to ablative local therapy; the success of such therapy depends on whether or not additional occult metastases exist. A model is presented here to predict occult metastases given detectable oligometastases. Predictions were based on Bayes' theorem, in conjunction with descriptions of the statistical distributions for the sizes and numbers of hematogenous metastases. The background probability for occult metastases in individuals with oligometastases increased markedly with relatively minor increases in metastatic potential. With each additional metastasis detected the chance of further occult metastases increased. These latter increases were incremental and proportionately smaller with the more metastatic tumors. Long disease free intervals had a major effect to decrease in the probability of further occult disease. Demonstration of oligometastases depends heavily upon the sensitivity of radiological imaging techniques, where the proportion of detectable metastases relates to the position of the distribution of metastasis growth times with respect to the detection threshold. Given the limitations of radiological methods, and the possibility that the oligometastases detected may be the only disease, an aggressive approach appears indicated. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Urine culture

    Science.gov (United States)

    Culture and sensitivity - urine ... when urinating. You also may have a urine culture after you have been treated for an infection. ... when bacteria or yeast are found in the culture. This likely means that you have a urinary ...

  7. Occult spinal dysraphism

    African Journals Online (AJOL)

    paediatricians, paediatric neurosurgeons, urologists, orthopaedic surgeons, occupational ... Occult spinal dysraphism refers to a diverse group of congenital abnormalities resulting from varying degrees of disordered neuro- embryogenesis. Several terms have .... can image the whole spine. T1-weighted sagittal and axial ...

  8. Fecal Occult Blood Test and Gastrointestinal Parasitic Infection

    Directory of Open Access Journals (Sweden)

    Majed H. Wakid

    2010-01-01

    Full Text Available Stool specimens of 1238 workers in western region of Saudi Arabia were examined for infection with intestinal parasites and for fecal occult blood (FOB to investigate the possibility that enteroparasites correlate to occult intestinal bleeding. Direct smears and formal ether techniques were used for detection of diagnostic stages of intestinal parasites. A commercially available guaiac test was used to detect fecal occult blood. 47.01% of the workers were infected with intestinal parasites including eight helminthes species and eight protozoan species. The results provided no significant evidence (P-value=0.143 that intestinal parasitic infection is in association with positive guaiac FOB test.

  9. Low occurrence of HBsAg but high frequency of transient occult HBV infection in vaccinated and HBIG-administered infants born to HBsAg positive mothers.

    Science.gov (United States)

    Zhou, Shan; Li, Tingting; Allain, Jean-Pierre; Zhou, Bin; Zhang, Yuming; Zhong, Mei; Fu, Yongshui; Li, Chengyao

    2017-12-01

    The status of chronic and occult HBV infection (OBI) in neonatal hepatitis B vaccine and immunoglobulin (HBIG) vaccinated infants born to HBsAg+ mothers was investigated at a major hospital in China. Seventy-seven and 15 blood samples were collected in first or second follow-up detection from the vaccinated babies aged 3-36 months born to 43 HBsAg+ or plus 25 HBeAg+ mothers. HBV infection was analyzed between the paired baby and mother by serology and DNA analysis. Among 77 children born to 68 HBsAg+ mothers, 3.9% (3/77) were HBsAg+, and 36.4% (28/77) were HBV DNA+/HBsAg- (OBIs) by a single PCR, respectively. Thirteen of 28 HBV DNA+/HBsAg- samples were conformed by two PCRs or S sequence, which accounted for 16.9% (13/77) of children. Three HBsAg+ and six OBIs were genotyped in consistent with their mother's HBV strains. Of 77 babies' blood samples, anti-HBs reactivity varied slightly according to age groups, while passively transmitted anti-HBc reactivity declined from 100% high reactivity at age 3-5 months to mostly negative at age ≥12 months. Babies with apparent OBI had higher levels of anti-HBc and lower levels of anti-HBs than those without OBI but all eight OBI babies with second follow-up samples became HBV DNA negative beyond 1 year of age. The vaccinated infants born to HBsAg+ mothers presented the low rate of HBsAg occurrence as vaccination failure and high frequency of viral persistence in the form of transient OBIs since no evidence of active HBV infection occurred beyond 1 year of age. © 2017 Wiley Periodicals, Inc.

  10. Occult Macular Dystrophy

    Directory of Open Access Journals (Sweden)

    Işıl Sayman Muslubaş

    2016-04-01

    Full Text Available Occult macular dystrophy is an inherited macular dystrophy characterized by a progressive decline of bilateral visual acuity with normal fundus appearance, fluorescein angiogram and full-field electroretinogram. This case report presents a 20-year-old female patient with bilateral progressive decline of visual acuity for six years. Her visual acuity was 3-4/10 in both eyes. Anterior segment and fundus examination, fluorescein angiogram and full-field electroretinogram were normal. She could read all Ishihara pseudoisochromatic plates. Fundus autofluorescence imaging was normal. There was a mild central hyporeflectance on fundus infrared reflectance imaging in both eyes. Reduced foveal thickness and alterations of the photoreceptor inner and outer segment junction were observed by optical coherence tomography in both eyes. Central scotoma was also found by microperimetry and reduced central response was revealed by multifocal electroretinogram in both eyes. These findings are consistent with the clinical characteristics of occult macular dystrophy

  11. Occult carbon monoxide poisoning.

    Science.gov (United States)

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  12. Occult Carbon Monoxide Poisoning

    OpenAIRE

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms ...

  13. Occult pneumothorax, revisited

    OpenAIRE

    Mangar Devanand; Abdelmalak Hany; Omar Hesham R; Rashad Rania; Helal Engy; Camporesi Enrico M

    2010-01-01

    Abstract Pneumothorax is a recognized cause of preventable death following chest wall trauma where a simple intervention can be life saving. In cases of trauma patients where cervical spine immobilization is mandatory, supine AP chest radiograph is the most practical initial study. It is however not as sensitive as CT chest for early detection of a pneumothorax. "Occult" pneumothorax is an accepted definition of an existing but usually a clinically and radiologically silent disturbance that i...

  14. GAMBARAN RADIOLOGIS PADA OCCULT PNEUMOTHORAKS

    Directory of Open Access Journals (Sweden)

    Putu Aditha Satya Putra

    2013-02-01

    Full Text Available Pneumothorax is a recognized cause of death in chest wall trauma. Radiological examination is the key factor to establish the existence of a pneumothorax. Occult pneumothorax is pneumothorax that undiagnosed clinically and with thoracic x-ray, but it can be tolerated while other more urgent trauma. Occult pneumothorax can be detected by CT (Computed tomography. Occult pneumothorax may progress to tension pneumothorax in certain circumstances. Missing in diagnosed pneumothorax will cause death. This literature will discuss radiological examination for diagnosing, early detection, and management of occult pneumothorax. If thoracic x-ray examination did not reveal the occult pneumothorax, it can be dangerous if existence of pneumothorax was not known. In this case, the examination of thoracic CT-Scan is gold standard for determining the presence of occult pneumothorax and can provide appropriate care.

  15. GAMBARAN RADIOLOGIS PADA OCCULT PNEUMOTHORAKS

    OpenAIRE

    Putu Aditha Satya Putra; Nyoman Srie Laksminingsih

    2013-01-01

    Pneumothorax is a recognized cause of death in chest wall trauma. Radiological examination is the key factor to establish the existence of a pneumothorax. Occult pneumothorax is pneumothorax that undiagnosed clinically and with thoracic x-ray, but it can be tolerated while other more urgent trauma. Occult pneumothorax can be detected by CT (Computed tomography). Occult pneumothorax may progress to tension pneumothorax in certain circumstances. Missing in diagnosed pneumothorax will cause deat...

  16. Myoglobin urine test

    Science.gov (United States)

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  17. Occult hepatitis B infection: an evolutionary scenario

    Directory of Open Access Journals (Sweden)

    Lukashov Vladimir V

    2008-12-01

    Full Text Available Abstract Background Occult or latent hepatitis B virus (HBV infection is defined as infection with detectable HBV DNA and undetectable surface antigen (HBsAg in patients' blood. The cause of an overt HBV infection becoming an occult one is unknown. To gain insight into the mechanism of the development of occult infection, we compared the full-length HBV genome from a blood donor carrying an occult infection (d4 with global genotype D genomes. Results The phylogenetic analysis of polymerase, core and X protein sequences did not distinguish d4 from other genotype D strains. Yet, d4 surface protein formed the evolutionary outgroup relative to all other genotype D strains. Its evolutionary branch was the only one where accumulation of substitutions suggests positive selection (dN/dS = 1.3787. Many of these substitutiions accumulated specifically in regions encoding the core/surface protein interface, as revealed in a 3D-modeled protein complex. We identified a novel RNA splicing event (deleting nucleotides 2986-202 that abolishes surface protein gene expression without affecting polymerase, core and X-protein related functions. Genotype D strains differ in their ability to perform this 2986-202 splicing. Strains prone to 2986-202 splicing constitute a separate clade in a phylogenetic tree of genotype D HBVs. A single substitution (G173T that is associated with clade membership alters the local RNA secondary structure and is proposed to affect splicing efficiency at the 202 acceptor site. Conclusion We propose an evolutionary scenario for occult HBV infection, in which 2986-202 splicing generates intracellular virus particles devoid of surface protein, which subsequently accumulates mutations due to relaxation of coding constraints. Such viruses are deficient of autonomous propagation and cannot leave the host cell until it is lysed.

  18. Sensitive monitoring of monoterpene metabolites in human urine using two-step derivatisation and positive chemical ionisation-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Schmidt, Lukas; Belov, Vladimir N.; Göen, Thomas

    2013-01-01

    Highlights: •Sensitive monitoring of 10 metabolites of (R)-limonene, α-pinene, and Δ 3 -carene in human urine samples. •Fast and simple sample preparation and derivatisation procedure using two-step silylation for unreactive tertiary hydroxyl groups. •Synthesis of reference substances and isotopically labelled internal standards of (R)-limonene, α-pinene, and Δ 3 -carene metabolites. •Study on (R)-limonene, α-pinene, and Δ 3 -carene metabolite background exposure of 36 occupationally unexposed volunteers. -- Abstract: A gas chromatographic–positive chemical ionisation-tandem mass spectrometric (GC–PCI-MS/MS) method for the simultaneous determination of 10 oxidative metabolites of the monoterpenoid hydrocarbons α-pinene, (R)-limonene, and Δ 3 -carene ((+)-3-carene) in human urine was developed and tested for the monoterpene biomonitoring of the general population (n = 36). The method involves enzymatic cleavage of the glucuronides followed by solid-supported liquid–liquid extraction and derivatisation using a two-step reaction with N,O-bis(trimethylsilyl)-trifluoroacetamide and N-(trimethylsilyl)imidazole. The method proved to be both sensitive and reliable with detection limits ranging from 0.1 to 0.3 μg L −1 . In contrast to the frequent and distinct quantities of (1S,2S,4R)-limonene-1,2-diol, the (1R,2R,4R)-stereoisomer could not be detected. The expected metabolite of (+)-3-carene, 3-caren-10-ol was not detected in any of the samples. All other metabolites were detected in almost all urine samples. The procedure enables for the first time the analysis of trace levels of a broad spectrum of mono- and bicyclic monoterpenoid metabolites (alcohols, diols, and carboxylic acids) in human urine. This analytical procedure is a powerful tool for population studies as well as for the discovery of human metabolism and toxicokinetics of monoterpenes

  19. Occult fractures of the knee: tomographic evaluation

    International Nuclear Information System (INIS)

    Apple, J.S.; Martinez, S.; Allen, N.B.; Caldwell, D.S.; Rice, J.R.

    1983-01-01

    Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans may be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture

  20. A comparison of different strategies used to invite subjects with a positive faecal occult blood test to a colonoscopy assessment. A randomised controlled trial in population-based screening programmes.

    Science.gov (United States)

    Zorzi, Manuel; Giorgi Rossi, Paolo; Cogo, Carla; Falcini, Fabio; Giorgi, Daniela; Grazzini, Grazia; Mariotti, Loretta; Matarese, Vincenzo; Soppelsa, Fabio; Senore, Carlo; Ferro, Antonio

    2014-08-01

    The purpose of this parallel randomised controlled trial was to compare compliance with different modalities used to invite patients with a positive immunochemical faecal occult blood test (FIT+) for a total colonoscopy (TC). FIT+ patients from nine Italian colorectal cancer screening programmes were randomised to be invited for a TC initially by mail or by phone and, for non-compliers, to be recalled by mail, for counselling with a general practitioner, or to meet with a specialist screening practitioner (nurse or healthcare assistant). In all, 3777 patients were randomised to different invitation strategies. Compliance with an initial invitation by mail and by phone was similar (86.0% vs. 84.0%, relative risk - RR: 1.02; 95%CI 0.97-1.08). Among non-responders to the initial invitation, compliance with a recall by appointment with a specialist practitioner was 50.4%, significantly higher than with a mail recall (38.1%; RR:1.33; 95%CI 1.01-1.76) or with a face-to-face counselling with the GP (30.8%; RR:1.45;95%CI 1.14-1.87). Compliance with an initial invitation for a TC by mail and by phone was similar. A personal meeting with a specialist screening practitioner was associated with the highest compliance among non-compliers with initial invitations, while the involvement of GPs in this particular activity seemed less effective. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Effects of a health education and telephone counseling program on patients with a positive fecal occult blood test result for colorectal cancer screening: A randomized controlled trial.

    Science.gov (United States)

    Chiu, Hui-Chuan; Hung, Hsin-Yuan; Lin, Hsiu-Chen; Chen, Shu-Ching

    2017-10-01

    Our purpose was to evaluate the effects of a health education and telephone counseling program on knowledge and attitudes about colorectal cancer and screening and the psychological impact of positive screening results. A randomized controlled trial was conducted with 2 groups using a pretest and posttest measures design. Patients with positive colorectal cancer screening results were selected and randomly assigned to an experimental (n = 51) or control (n = 51) group. Subjects in the experimental group received a health education and telephone counseling program, while the control group received routine care only. Patients were assessed pretest before intervention (first visit to the outpatient) and posttest at 4 weeks after intervention (4 weeks after first visit to the outpatient). Patients in the experimental group had a significantly better level of knowledge about colorectal cancer and the psychological impact of a positive screening result than did the control group. Analysis of covariance revealed that the health education and telephone counseling program had a significant main effect on colorectal cancer knowledge. A health education and telephone counseling program can improve knowledge about colorectal cancer and about the psychological impact in patients with positive colorectal cancer screening results. The health education and telephone counseling program is an easy, simple, and convenient method of improving knowledge, improving attitudes, and alleviating psychological distress in patients with positive colorectal cancer screening results, and this program can be expanded to other types of cancer screening. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Modified Reporting of Positive Urine Cultures to Reduce Inappropriate Treatment of Asymptomatic Bacteriuria Among Nonpregnant, Noncatheterized Inpatients: A Randomized Controlled Trial.

    Science.gov (United States)

    Daley, Peter; Garcia, David; Inayatullah, Raheel; Penney, Carla; Boyd, Sarah

    2018-05-28

    DESIGNWe conducted a randomized, parallel, unblinded, superiority trial of a laboratory reporting intervention designed to reduce antibiotic treatment of asymptomatic bacteriuria (ASB).METHODSResults of positive urine cultures from 110 consecutive inpatients at 2 urban acute-care hospitals were randomized to standard report (control) or modified report (intervention). The standard report included bacterial count, bacterial identification, and antibiotic susceptibility information including drug dosage and cost. The modified report stated: "This POSITIVE urine culture may represent asymptomatic bacteriuria or urinary tract infection. If urinary tract infection is suspected clinically, please call the microbiology laboratory … for identification and susceptibility results." We used the following exclusion criteria: age pregnancy, presence of an indwelling urinary catheter, samples from patients already on antibiotics, neutropenia, or admission to an intensive care unit. The primary efficacy outcome was the proportion of appropriate antibiotic therapy prescribed.RESULTSAccording to our intention-to-treat (ITT) analysis, the proportion of appropriate treatment (urinary tract infection treated plus ASB not treated) was higher in the modified arm than in the standard arm: 44 of 55 (80.0%) versus 29 of 55 (52.7%), respectively (absolute difference, -27.3%; RR, 0.42; P = .002; number needed to report for benefit, 3.7).CONCLUSIONSModified reporting resulted in a significant reduction in inappropriate antibiotic treatment without an increase in adverse events. Safety should be further assessed in a large effectiveness trial before implementationTRIAL REGISTRATION. clinicaltrials.gov#NCT02797613Infect Control Hosp Epidemiol 2018;1-6.

  3. Ultrasound detection of nonpalpable mammographically occult malignancy

    International Nuclear Information System (INIS)

    Simpson, W.L.; Hermann, G.; Rausch, D.R.; Sherman, J.; Feig, S.A.; Bleiweiss, I.J.; Jaffer, S.

    2008-01-01

    To evaluate the prevalence of occult malignancy with screening breast ultrasound. All ultrasound-guided core needle breast biopsies performed between January 1, 1999, and June 30, 2001, were retrospectively reviewed. Lesions were identified during screening breast ultrasound in high-risk women with no mammographic or palpable abnormality in either breast, a unilateral mammographic or palpable abnormality in the contralateral breast, or a unilateral mammographic or palpable abnormality in a different quadrant of the same breast. All ultrasound-detected lesions were histologically verified. Six hundred and fifty-two women with a mean age of 49 years underwent 698 biopsies during the study period. Three hundred and forty-nine of these lesions were detected at screening breast ultrasound. Out of 349, 11 (3.2%) had a mammographically and clinically occult malignancy. Nine cancers were found in women with no mammographic or palpable abnormality. Two cancers were found in the same breast as the mammographic or palpable abnormality. None were found in the breast contralateral to a palpable or mammographic abnormality. Screening breast ultrasound of high-risk women has a similar detection rate for occult carcinoma as screening mammography, but has a low positive predictive value in cases where biopsy is performed. (author)

  4. Urine Odor

    Science.gov (United States)

    ... doctor. Brunzel NA. Physical examination of urine. In: Fundamentals of Urine and Body Fluid Analysis. 3rd ed. St. Louis, Mo.: Saunders Elsevier; 2013:97. McPherson RA, et al., eds. Henry's Clinical Diagnosis and Management by Laboratory Methods. 23rd ed. St. Louis, Mo.: ...

  5. Beamsteerable GNSS Radio Occultation ASIC

    Data.gov (United States)

    National Aeronautics and Space Administration — We will develop an integrated RF ASIC to enable high quality radio occultation (RO) weather observations using the Global Navigations System Satellite (GNSS)...

  6. Predictions of stellar occultations by TNOs/Centaurs using Gaia

    Science.gov (United States)

    Desmars, Josselin; Camargo, Julio; Berard, Diane; Sicardy, Bruno; Leiva, Rodrigo; Vieira-Martins, Roberto; Braga-Ribas, Felipe; Assafin, Marcelo; Rossi, Gustavo; Chariklo occultations Team, Rio Group, Lucky Star Occultation Team, Granada Occultation Team

    2017-10-01

    Stellar occultations are the unique technique from the ground to access physical parameters of the distant solar system objects, such as the measure of the size and the shape at kilometric level, the detection of tenuous atmospheres (few nanobars), and the investigation of close vicinity (satellites, rings, jets).Predictions of stellar occultations require accurate positions of the star and the object.The Gaia DR1 catalog now allows to get stellar position to the milliarcsecond (mas) level. The main uncertainty in the prediction remains in the position of the object (tens to hundreds of mas).Now, we take advantage of the NIMA method for the orbit determination that uses the most recent observations reduced by the Gaia DR1 catalog and the astrometric positions derived from previous positive occultations.Up to now, we have detected nearly 50 positive occultations for about 20 objects that provide astrometric positions of the object at the time of the occultation. The uncertainty of these positions only depends on the uncertainty on the position of the occulted stars, which is a few mas with the Gaia DR1 catalog. The main limitation is now on the proper motion of the star which is only given for bright stars in the Tycho-Gaia Astrometric Solution. This limitation will be solved with the publicationof the Gaia DR2 expected on April 2018 giving proper motions and parallaxes for the Gaia stars. Until this date, we use hybrid stellar catalogs (UCAC5, HSOY) that provide proper motions derived from Gaia DR1 and another stellar catalog.Recently, the Gaia team presented a release of three preliminary Gaia DR2 stellar positions involved in the occultations by Chariklo (22 June and 23 July 2017) and by Triton (5 October 2017).Taking the case of Chariklo as an illustration, we will present a comparison between the proper motions of DR2 and the other catalogs and we will show how the Gaia DR2 will lead to a mas level precision in the orbit and in the prediction of stellar

  7. Esophageal Metastasis From Occult Lung Cancer

    Directory of Open Access Journals (Sweden)

    Po-Kuei Hsu

    2010-06-01

    Full Text Available A 66-year-old man with dysphagia was found to have a poorly differentiated esophageal carcinoma by incision biopsy. Following esophagectomy, reconstruction with a gastric tube was performed. Pathological examination and immunohisto-chemistry showed infiltration of adenocarcinoma cells with positive thyroid transcription factor 1-staining in the submucosal layer, which indicated metastatic esophageal carcinoma. Although no pulmonary lesion could be visualized by imaging or bronchoscopy, pulmonary origin was highly suspected as a result of positive thyroid transcription factor 1-staining. To the best of our knowledge, this is the first reported case of metastatic esophageal carcinoma from occult lung cancer (AJCC TNM stage TX.

  8. Sensitive monitoring of monoterpene metabolites in human urine using two-step derivatisation and positive chemical ionisation-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Lukas [Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, University of Erlangen-Nuremberg, Schillerstrasse 25/29, 91054 Erlangen (Germany); Belov, Vladimir N. [Max Planck Institute for Biophysical Chemistry, Facility for Synthetic Chemistry, Am Fassberg 11, 37077 Göttingen (Germany); Göen, Thomas, E-mail: Thomas.Goeen@ipasum.med.uni-erlangen.de [Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, University of Erlangen-Nuremberg, Schillerstrasse 25/29, 91054 Erlangen (Germany)

    2013-09-02

    Highlights: •Sensitive monitoring of 10 metabolites of (R)-limonene, α-pinene, and Δ{sup 3}-carene in human urine samples. •Fast and simple sample preparation and derivatisation procedure using two-step silylation for unreactive tertiary hydroxyl groups. •Synthesis of reference substances and isotopically labelled internal standards of (R)-limonene, α-pinene, and Δ{sup 3}-carene metabolites. •Study on (R)-limonene, α-pinene, and Δ{sup 3}-carene metabolite background exposure of 36 occupationally unexposed volunteers. -- Abstract: A gas chromatographic–positive chemical ionisation-tandem mass spectrometric (GC–PCI-MS/MS) method for the simultaneous determination of 10 oxidative metabolites of the monoterpenoid hydrocarbons α-pinene, (R)-limonene, and Δ{sup 3}-carene ((+)-3-carene) in human urine was developed and tested for the monoterpene biomonitoring of the general population (n = 36). The method involves enzymatic cleavage of the glucuronides followed by solid-supported liquid–liquid extraction and derivatisation using a two-step reaction with N,O-bis(trimethylsilyl)-trifluoroacetamide and N-(trimethylsilyl)imidazole. The method proved to be both sensitive and reliable with detection limits ranging from 0.1 to 0.3 μg L{sup −1}. In contrast to the frequent and distinct quantities of (1S,2S,4R)-limonene-1,2-diol, the (1R,2R,4R)-stereoisomer could not be detected. The expected metabolite of (+)-3-carene, 3-caren-10-ol was not detected in any of the samples. All other metabolites were detected in almost all urine samples. The procedure enables for the first time the analysis of trace levels of a broad spectrum of mono- and bicyclic monoterpenoid metabolites (alcohols, diols, and carboxylic acids) in human urine. This analytical procedure is a powerful tool for population studies as well as for the discovery of human metabolism and toxicokinetics of monoterpenes.

  9. Preponderance of bacterial isolates in urine of HIV-positive malaria-infected pregnant women with urinary tract infection.

    Science.gov (United States)

    Ako-Nai, Kwashie Ajibade; Ebhodaghe, Blessing Itohan; Osho, Patrick; Adejuyigbe, Ebun; Adeyemi, Folasade Mubiat; Kassim, Olakunle O

    2014-12-15

    This study examined HIV and malaria co-infection as a risk factor for urinary tract infections (UTIs) in pregnancy. The study group included 74 pregnant women, 20 to 42 years of age, who attended the antenatal clinic at the Specialist Hospital at Akure, Ondo State, Nigeria. Forty-four of the pregnant women were either HIV seropositive with malaria infection (HIV+Mal+) or HIV seropositive without malaria (HIV+Mal-). The remaining thirty pregnant women served as controls and included women HIV seronegative but with malaria (HIV-Mal+) and women HIV seronegative without malaria. UTI was indicated by a bacterial colony count of greater than 10⁵/mL of urine, using cysteine lactose electrolyte deficient medium (CLED) as the primary isolation medium. Bacterial isolates were characterized using convectional bacteriological methods, and antibiotics sensitivity tests were carried out using the disk diffusion method. A total of 246 bacterial isolates were recovered from the cultures, with a mean of 3.53 isolates per subject. Women who were HIV+Mal+ had the most diverse group of bacterial isolates and the highest frequency of UTIs. The bacterial isolates from the HIV+Mal+ women also showed the highest degree of antibiotic resistance. While pregnancy and HIV infection may each represent a risk factor for UTI, HIV and malaria co-infection may increase its frequency in pregnancy. The higher frequency of multiple antibiotic resistance observed among the isolates, particularly isolates from HIV+Mal+ subjects, poses a serious public health concern as these strains may aggravate the prognosis of both UTI and HIV infection.

  10. Occult hepatitis B virus infection in immunocompromised patients

    Directory of Open Access Journals (Sweden)

    Ruth Nogueira Cordeiro Moraes Jardim

    Full Text Available Occult hepatitis B infection is characterized by hepatitis B virus (HBV DNA in the serum in the absence of hepatitis B surface antigen (HBsAg. We assessed occult HBV infection prevalence in two groups of immunocompromised patients (maintenance hemodialysis patients and HIV-positive patients presenting HBsAg-negative and anti-HBc positive serological patterns, co-infected or not by HCV. Thirty-four hemodialysis anti-HIV negative patients, 159 HIV-positive patients and 150 blood donors who were anti-HBc positive (control group were selected. HBV-DNA was detected by nested-PCR. Occult hepatitis B infection was not observed in the hemodialysis patients group but was found in 5% of the HIV-patients and in 4% of the blood donors. Immunosuppression in HIV positive patients was not a determining factor for occult HBV infection. In addition, no significant relationship between HBV-DNA and HCV co-infection in the HIV-positive patient group was found. A lack of significant associations was also observed between positivity for HBV-DNA and CD4 count, viral load and previous lamivudine treatment in these HIV-positive patients.

  11. Operation of the Radio Occultation Mission in KOMPSAT-5

    Directory of Open Access Journals (Sweden)

    Mansoo Choi

    2010-12-01

    Full Text Available Korea multi-purpose satellite-5 (KOMPSAT-5 is a low earth orbit (LEO satellite scheduled to be launched in 2010. To satisfy the precision orbit determination (POD requirement for a high resolution synthetic aperture radar image of KOMPSAT-5, KOMPSAT-5 has atmosphere occultation POD (AOPOD system which consists of a space-borne dual frequency global positioning system (GPS receiver and a laser retro reflector array. A space-borne dual frequency GPS receiver on a LEO satellite provides position data for the POD and radio occultation data for scientific applications. This paper describes an overview of AOPOD system and operation concepts of the radio occultation mission in KOMPSAT-5. We showed AOPOD system satisfies the requirements of KOMPSAT-5 in performance and stability.

  12. Urine Preservative

    Science.gov (United States)

    Smith, Scott M. (Inventor); Nillen, Jeannie (Inventor)

    2001-01-01

    Disclosed is CPG, a combination of a chlorhexidine salt (such as chlorhexidine digluconate, chlorhexidine diacetate, or chlorhexidine dichloride) and n-propyl gallate that can be used at ambient temperatures as a urine preservative.

  13. Urine Color

    Science.gov (United States)

    ... drugs can darken urine, including the antimalarial drugs chloroquine and primaquine, the antibiotics metronidazole (Flagyl) and nitrofurantoin ( ... Mayo Clinic Footer Legal Conditions and Terms Any use of this site constitutes your agreement to the ...

  14. Immunoelectrophoresis - urine

    Science.gov (United States)

    ... from an infant, you may need extra collection bags. How the Test will Feel The test involves ... urine, it normally consists of mainly albumin. Normal value ranges may vary slightly among different laboratories. Talk ...

  15. Massive venlafaxine overdose resulted in a false positive Abbott AxSYM (R) urine immunoassay for phencyclidine

    NARCIS (Netherlands)

    Bond, GR; Steele, PE; Uges, DRA

    2003-01-01

    Case report: A 13-yr-old girl overdosed on 48 x 150 mg venlafaxine (Effexor XR(R)). She was taking venlafaxine regularly for depression. Her only other medications included topical Benzamycin and pyridoxine 50 mg daily for acne. The Abbott AxSYM(R) assay was positive only for phencyclidine, but

  16. Current management of occult bacteremia in infants

    Directory of Open Access Journals (Sweden)

    Eduardo Mekitarian Filho

    2015-11-01

    Full Text Available Objectives: To summarize the main clinical entities associated with fever without source (FWS in infants, as well as the clinical management of children with occult bacteremia, emphasizing laboratory tests and empirical antibiotics. Sources: A non-systematic review was conducted in the following databases – PubMed, EMBASE, and SciELO, between 2006 and 2015. Summary of the findings: The prevalence of occult bacteremia has been decreasing dramatically in the past few years, due to conjugated vaccination against Streptococcus pneumoniae and Neisseria meningitidis. Additionally, fewer requests for complete blood count and blood cultures have been made for children older than 3 months presenting with FWS. Urinary tract infection is the most prevalent bacterial infection in children with FWS. Some known algorithms, such as Boston and Rochester, can guide the initial risk stratification for occult bacteremia in febrile infants younger than 3 months. Conclusions: There is no single algorithm to estimate the risk of occult bacteremia in febrile infants, but pediatricians should strongly consider outpatient management in fully vaccinated infants older than 3 months with FWS and good general status. Updated data about the incidence of occult bacteremia in this environment after conjugated vaccination are needed. Resumo: Objetivos: Listar as principais entidades clínicas associadas a quadros de febre sem sinais localizatórios (FSSL em lactentes, bem como o manejo dos casos de bacteremia oculta com ênfase na avaliação laboratorial e na antibioticoterapia empírica. Fonte dos dados: Foi realizada revisão não sistemática da literatura nas bases de dados PubMed, EMBASE e Scielo no período de 2006 a 2015. Síntese dos dados: A ocorrência de bacteremia oculta vem diminuindo sensivelmente em lactentes com FSSL, principalmente devido à introdução da vacinação conjugada contra Streptococcus pneumoniae e Neisseria meningitidis nos últimos anos

  17. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  18. Crosslink Radio Occultation for the Remote Sensing of Planetary Atmospheres

    Science.gov (United States)

    Mannucci, A. J.; Ao, C. O.; Asmar, S.; Edwards, C. D.; Kahan, D. S.; Paik, M.; Pi, X.; Williamson, W.

    2015-12-01

    Radio occultation utilizing deep space telecommunication signals has been used with great success in the profiling of planetary atmospheres and ionospheres since the 1960s. A shortcoming of this technique, however, is the limited temporal and spatial sampling that it provides. We consider a different approach where radio occultation measurements are taken between two spacecraft orbiting an extra-terrestrial body. Such "crosslink" radio occultations between the Global Positioning System satellites and low-earth orbiting spacecraft have been routinely acquired to provide global observations of the Earth's atmosphere and ionosphere that are used for weather forecast, climate analysis, and space weather applications. The feasibility of applying this concept to other planets has recently been demonstrated for the first time, where crosslink occultation measurements have been acquired between the Mars Odyssey and Mars Reconnaissance Orbiter spacecraft. These measurements leverage the proximity link telecommunication payloads on each orbiter, which are nominally used to provide relay communication and navigation services to Mars landers and rovers. In this presentation, we will describe the Mars crosslink experiments and the corresponding data analysis in detail. In addition, we will discuss how the crosslink occultation concepts can be effectively applied in future space exploration missions.

  19. Occult Phenomena in Sherlock Holmes the Movie

    OpenAIRE

    NAMAZCARRA, CHRIESHER

    2014-01-01

    Keywords: Occult phenomena, Sherlock Holmes, movie. Lately, it is not difficult for people to find occult practices. There are many television programs and movie which air mystical programme aggressively to raise the rating and attract the viewers. A movie that raise occultism theme is Sherlock Holmes, the Movie. This movie tells about the struggle of detective Sherlock Holmes to fight the black magic power of Lord Blackwood.To carry out the study, the theories of Occultism such as the secrec...

  20. Molecular and serological detection of occult hepatitis B virus ...

    African Journals Online (AJOL)

    hepatitis B surface antigen-negative blood donors in Malaysia. ... Objective: This study aimed to detect occult hepatitis B virus in hepatitis B surface .... of the standard HBV-positive serum and the detection ... in general population ranges from 1.5 to 9.8% but report- .... Putra, Malaysia for their financial support of this research.

  1. Lunar occultation observations of the Crab Nebula

    International Nuclear Information System (INIS)

    Maloney, F.P.

    1977-01-01

    Three lunar of occultations of the Crab Nebula were observed, two at 114 MHz and one at 26.3 MHz, during the 1974 series of events. The higher frequency observations were deconvolved of diffraction effects to yield four strip integrated brightness profiles of the Nebula, with an effective resolution of 30 arc-seconds. These four profiles were Fourier inverted and cleaned of sidelobe structure to synthesize a two-dimensional map of the Nebula. At 114 MHz, the Nebula is composed of a broad envelope of emission which contains several smaller sources. The attenuation of the low radio frequency radiation by the thermal hydrogen in the filaments is considered as a possible mechanism to explain these new data. The 26.3 MHz observations indicate the presence of a bright, localized source containing greater than 80% of the flux of the Nebula. The position of the source is confined by the data to a narrow strip centered at the pulsar position. Both sets of data are compared with past occultation observations

  2. Urine: Waste product or biologically active tissue?

    Science.gov (United States)

    2018-03-01

    Historically, urine has been viewed primarily as a waste product with little biological role in the overall health of an individual. Increasingly, data suggest that urine plays a role in human health beyond waste excretion. For example, urine might act as an irritant and contribute to symptoms through interaction with-and potential compromise of-the urothelium. To explore the concept that urine may be a vehicle for agents with potential or occult bioactivity and to discuss existing evidence and novel research questions that may yield insight into such a role, the National Institute of Diabetes and Digestive and Kidney Disease invited experts in the fields of comparative evolutionary physiology, basic science, nephrology, urology, pediatrics, metabolomics, and proteomics (among others) to a Urinology Think Tank meeting on February 9, 2015. This report reflects ideas that evolved from this meeting and current literature, including the concept of urine quality, the biological, chemical, and physical characteristics of urine, including the microbiota, cells, exosomes, pH, metabolites, proteins, and specific gravity (among others). Additionally, the manuscript presents speculative, and hopefully testable, ideas about the functional roles of urine constituents in health and disease. Moving forward, there are several questions that need further understanding and pursuit. There were suggestions to consider actively using various animal models and their biological specimens to elaborate on basic mechanistic information regarding human bladder dysfunction. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  3. Progress on the occulter experiment at Princeton

    Science.gov (United States)

    Cady, Eric; Balasubramanian, Kunjithapatham; Carr, Michael; Dickie, Matthew; Echternach, Pierre; Groff, Tyler; Kasdin, Jeremy; Laftchiev, Christian; McElwain, Michael; Sirbu, Dan; Vanderbei, Robert; White, Victor

    2009-08-01

    An occulter is used in conjunction with a separate telescope to suppress the light of a distant star. To demonstrate the performance of this system, we are building an occulter experiment in the laboratory at Princeton. This experiment will use an etched silicon mask as the occulter, with some modifications to try to improve the performance. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. We present the progress of this experiment and expectations for future work.

  4. Occult hepatitis B among Iranian hepatitis C patients

    Directory of Open Access Journals (Sweden)

    Ahmad shavakhi

    2009-02-01

    Full Text Available

    • BACKGROUND: Occult hepatitis B is defined as presence of HBV DNA in tissue or serum without hepatitis B surface antigen. The aim of this study is to determine frequency of occult hepatitis B among hepatitis C patients in Tehran and compare the route of transmission and liver enzymes between positive and negative HBV DNA patients.
    • METHODS: In a cross sectional study, serum of 103 hepatitis C cases (79.6% men and 20.4% women were analyzed for s, x and core genes via a nested polymerase chain reaction technique.
    • RESULTS: HBV DNA was detectable in serum of 20 patients (19.4%. No significant difference in age, sex and route of transmission were seen in HBV DNA positive and negative patients. In HBV DNA positive and negative groups, mean of AST was 73, 47 (p < 0.05 and mean of ALT was 76 and 36 respectively (p < 0.05.
    • CONCLUSION: Occult hepatitis B was observed in a considerable number of hepatitis C patients in Tehran. It was associated with elevation in liver enzyme but was not related to route of transmission.
    • KEY WORD: Occult hepatitis B, hepatitis C, cirrhosis.

  5. Calcium - urine

    Science.gov (United States)

    ... Female urinary tract Male urinary tract Calcium urine test References Bringhurst FR, Demay MB, Kronenberg HM. Hormones and disorders of mineral metabolism. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; ...

  6. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  7. Occult HBV infection in HIV-infected adults and evaluation of pooled NAT for HBV.

    Science.gov (United States)

    Dinesha, T R; Boobalan, J; Sivamalar, S; Subashini, D; Solomon, S S; Murugavel, K G; Balakrishnan, P; Smith, D M; Saravanan, S

    2018-01-06

    The study aimed to determine the prevalence of occult hepatitis B virus infection among HIV-infected persons and to evaluate the use of a pooling strategy to detect occult HBV infection in the setting of HIV infection. Five hundred and two HIV-positive individuals were tested for HBV, occult HBV and hepatitis C and D with serologic and nucleic acid testing (NAT). We also evaluated a pooled NAT strategy for screening occult HBV infection among the HIV-positive individuals. The prevalence of HBV infection among HIV-positive individuals was 32 (6.4%), and occult HBV prevalence was 10%. The pooling HBV NAT had a sensitivity of 66.7% and specificity of 100%, compared to HBV DNA NAT of individual samples. In conclusion, this study found a high prevalence of occult HBV infection among our HIV-infected population. We also demonstrated that pooled HBV NAT is highly specific, moderately sensitive and cost-effective. As conventional HBV viral load assays are expensive in resource-limited settings such as India, pooled HBV DNA NAT might be a good way for detecting occult HBV infection and will reduce HBV-associated complications. © 2018 John Wiley & Sons Ltd.

  8. The stellar occultation by the dwarf planet Haumea

    Science.gov (United States)

    Santos-Sanz, Pablo; Ortiz, Jose Luis; Sicardy, Bruno; Rossi, Gustavo; Berard, Diane; Morales, Nicolas; Duffard, Rene; Braga-Ribas, Felipe; Hopp, Ulrich; Ries, Christoph; Nascimbeni, Valerio; Marzari, Francesco; Granata, Valentina; Pál, András; Kiss, Csaba; Pribulla, Theodor; Milan Komzík, Richard; Hornoch, Kamil; Pravec, Petr; Bacci, Paolo; Maestripieri, Martina; Nerli, Luca; Mazzei, Leonardo; Bachini, Mauro; Martinelli, Fabio; Succi, Giacomo; Ciabattari, Fabrizio; Mikuz, Herman; Carbognani, Albino; Gaehrken, Bernd; Mottola, Stefano; Hellmich, Stephan; Rommel, Flavia; Fernández-Valenzuela, Estela; Campo Bagatin, Adriano; Haumea occultation international Collaboration: https://cloud.iaa.csic.es/public.php?service=files&t=d9276f8ab1a316cef13bee28bef75add

    2017-10-01

    The dwarf planet Haumea is a very peculiar Trans-Neptunian Object (TNO) with unique and exotic characteristics. It is currently classified as one of the five dwarf planets of the solar system, and it is the only one for which size, shape, albedo, density and other basic properties were not accurately known. To solve that we predicted an occultation of the star GaiaDR1 1233009038221203584 by Haumea and organized observations within the expected shadow path. Medium/large telescopes were needed to record the occultation with enough signal to noise ratio because the occulted star is of similar brightness as Haumea (R~17.7 mag). We will report results derived from this successful stellar occultation by Haumea on 2017 January 21st. The occultation was positive from 12 telescopes at 10 observing stations in Europe: the Asiago Observatory 1.8m telescope (Italy), the Mount Agliale Observatory 0.5m telescope (Italy), the Lajatico Astronomical Centre 0.5m telescope (Italy), the S.Marcello Pistoiese Observatory 0.6m telescope (Italy), the Crni Vrh Observatory 0.6m telescope (Slovenia), the Ondrejov Observatory 0.65m telescope (Czech Republic), the Bavarian Public Observatory 0.81m telescope (Germany), the Konkoly Observatory 1m and 0.6m telescopes (Hungary), the Skalnate Pleso Observatory 1.3m telescope (Slovakia), and the Wendelstein Observatory 2m and 0.4m telescopes (Germany). This is the occultation by a TNO with the largest number of chords ever recorded.Part of this work has received funding from the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement No. 687378.

  9. Diagnosis of occult abdominal abscesses using radioisotopes

    International Nuclear Information System (INIS)

    Koch, B.; Schroth, H.J.; Wolf, N.; Wilhelm, H.; Universitaet des Saarlandes, Homburg/Saar

    1983-01-01

    Occult intraperitoneal abscesses are difficult to localize and dispose of. Therefore, a method of examination is needed that is specific, can be used at any time, is not expensive, and yields early results within 2-3 h. This seems possible with a new method of examination. sup(99m)Tc-Sn-colloid was used to label autologous polymorphonuclear leukocytes which, when reinjected, emigrate to the site of the suspected abscess. Standard scintigraphy localizes the labeled inflammatory cells. Scans were performed in 57 surgical patients with good results. 23 (40,4%) patients had true negative results; 28 (49,1%) scans represented intraperitoneal abscesses; 5 (8,8%) scans demonstrated true positive extraperitoneal inflammations. Only 1 (1,7%) scan was false positive. (orig.) [de

  10. Radioimmune localization of occult carcinoma

    International Nuclear Information System (INIS)

    Duda, R.B.; Zimmer, A.M.; Rosen, S.T.; Gilyon, K.A.; Webber, D.; Spies, S.; Spies, W.; Merchant, B.

    1990-01-01

    Patients with a rising serum carcinoembryonic antigen level and no clinical or roentgenographic evidence of recurrent or metastatic cancer present a treatment dilemma. Eleven such patients, 10 with a previously treated colorectal carcinoma and 1 with a previously treated breast carcinoma, received an injection of the anticarcinoembryonic antigen monoclonal antibody ZCE-025 labeled with the radioisotope indium 111. Nuclear scintigraphy was performed on days 3 and 5 through 7 to detect potential sites of tumor recurrence. The monoclonal antibody scan accurately predicted the presence or absence of occult malignancy in 7 (64%) patients. Second-look laparotomy confirmed the monoclonal antibody scan results in the patients with colorectal cancer, and magnetic resonance imaging confirmed metastatic breast cancer. This study demonstrates that In-ZCE-025 can localize occult carcinoma and may assist the surgeon in facilitating the operative exploration. In-ZCE-025 assisted in the initiation of adjuvant therapy for the patient with breast cancer

  11. Occurrence of occult CSF leaks during standard FESS procedures.

    Science.gov (United States)

    Bucher, S; Kugler, A; Probst, E; Epprecht, L; Stadler, R S; Holzmann, D; Soyka, M B

    2018-03-18

    To determine the incidence of occult cerebrospinal fluid leaks (CSF) after functional endoscopic sinus surgery (FESS) and to evaluate the diagnostic performance of beta2-transferrin in blood-contaminated conditions. Prospective cohort study. An analysis of 57 intraoperative samples using hydrogel 6 beta2-transferrin assay after FESS was undertaken. In case of CSF positive samples and continuing rhinorrhea, reanalysis after more than 1 year was conducted. In-vivo analysis of a primary spontaneous CSF leak sample took place to verify difficulties in detecting beta2-transferrin in blood-contaminated settings. Own titrations were performed to evaluate detection limits of CSF by beta2-transferrin and beta-trace protein assays in these settings. An incidence of 13% for occult CSF leaks after FESS was found. In blood-contaminated conditions, routine beta2-transferrin assays showed low sensitivity. In over 1 year follow-up, all samples were negative for CSF and none of them developed clinical relevant CSF leaks or meningitis. Occult and clinically irrelevant CSF leaks do occur in a significant proportion of patients during and shortly after FESS. Intra- and postoperatively, routine beta2-transferrin assays show low sensitivity. They should not be used in these settings. The clinical course of patients with occult CSF leaks indicated possibility of an uneventful follow-up.

  12. OCCULT POWER AND AFRICA'S SOCIO-ECONOMIC PROBLEMS ...

    African Journals Online (AJOL)

    Dr Ike

    people believe in the existence of occult powers and this belief affects their ... make use of occult powers to solve their problems. For example, ... existence and influence of paranormal and occult powers, argues that ..... and friends.

  13. Occult cranium bifidium

    International Nuclear Information System (INIS)

    Inoue, Y.; Fukuda, T.; Nemoto, Y.; Hakuba, A.; Kitano, H.; Fujitani, K.; Umekawa, T.; Kobayashi, Y.

    1983-01-01

    Six cases of congenital subscalp nodule associated with underlying cranium bifidum are reported. A plain skull roentgenogram showed a midline bone defect in the parieto-occipital region near the lambda. CT scan demonstrated neither brain malformation nor ventricular deformity except for the high position of the straight sinus. Cerebral angiography revealed an elongation of the vein of Galen and anomalous upward course of the straight sinus. At surgery, the tumor was solid and connected to a cord which extended intracranially via the cranium bifidum and blended with thickened arachnoid membrane either on the dorsal aspect of the midbrain or at the surface of the anterior vermis. Histologically, the tumor consisted in all cases of arachnoid cells and fibrous tissue with immature glial cells in one case. Possible pathogenesis of these tumors could be a result of the fetal nuchal bleb. (orig.)

  14. Simultaneous pentafluorobenzyl derivatization and GC-ECNICI-MS measurement of nitrite and malondialdehyde in human urine : Close positive correlation between these disparate oxidative stress biomarkers

    NARCIS (Netherlands)

    Hanff, Erik; Eisenga, Michele F.; Beckmann, Bibiana; Bakker, Stephan J. L.; Tsikas, Dimitrios

    2017-01-01

    Urinary nitrite and malondialdehyde (MDA) are biomarkers of nitrosative and oxidative stress, respectively. At physiological pH values of urine and plasma, nitrite and MDA exist almost entirely in their dissociated forms, i.e., as ONO- (ONOH, p Kappa a =3.4) and -CH(CHO)(2) (CH2(CHO)(2), p Kappa a

  15. A variational regularization of Abel transform for GPS radio occultation

    OpenAIRE

    T.-K. Wee

    2018-01-01

    In the Global Positioning System (GPS) radio occultation (RO) technique, the inverse Abel transform of measured bending angle (Abel inversion, hereafter AI) is the standard means of deriving the refractivity. While concise and straightforward to apply, the AI accumulates and propagates the measurement error downward. The measurement error propagation is detrimental to the refractivity in lower altitudes. In particular, it builds up negative refractivity bias in the tropical ...

  16. Occultations for probing atmosphere and climate

    CERN Document Server

    Foelsche, Ulrich; Steiner, Andrea

    2004-01-01

    Use of occultation methodology for observing the Earth's atmosphere and climate has become so broad as to comprise solar, lunar, stellar, navigation and satellite­ crosslink occultation methods. The atmospheric parameters obtained extend from the fundamental variables temperature, density, pressure, water vapor, and ozone via a multitude of trace gas species to particulate species such as aerosols and cloud liquid water. Ionospheric electron density is sensed as well. The methods all share the key properties of self-calibration, high accuracy and vertical resolution, global coverage, and (if using radio signals) all-weather capability. Occultation data are thus of high value in a wide range of fields including climate monitoring and research, atmospheric physics and chemistry, operational meteorology, and other fields such as space weather and planetary science. This wide area of variants and uses of the occultation method has led to a diversi­ fication of the occultation-related scientific community into a...

  17. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  18. [Results of conservative treatment in patients with occult pneumothorax].

    Science.gov (United States)

    Llaquet Bayo, Heura; Montmany Vioque, Sandra; Rebasa, Pere; Navarro Soto, Salvador

    2016-04-01

    An occult pneumothorax is found in 2-15% trauma patients. Observation (without tube thoracostomy) in these patients presents still some controversies in the clinical practice. The objective of the study is to evaluate the efficacy and the adverse effects when observation is performed. A retrospective observational study was undertaken in our center (university hospital level II). Data was obtained from a database with prospective registration. A total of 1087 trauma patients admitted in the intensive care unit from 2006 to 2013 were included. In this period, 126 patients with occult pneumothorax were identified, 73 patients (58%) underwent immediate tube thoracostomy and 53 patients (42%) were observed. Nine patients (12%) failed observation and required tube thoracostomy for pneumothorax progression or hemothorax. No patient developed a tension pneumothorax or experienced another adverse event related to the absence of tube thoracostomy. Of the observed patients 16 were under positive pressure ventilation, in this group 3 patients (19%) failed observation. There were no differences in mortality, hospital length of stay or intensive care length of stay between the observed and non-observed group. Observation is a safe treatment in occult pneumothorax, even in pressure positive ventilated patients. Copyright © 2014 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Sociology of religion and the occult revival

    Directory of Open Access Journals (Sweden)

    Lennart Ejerfeldt

    1975-01-01

    Full Text Available The "new" that makes the cults of the occult revival to "new religions" of the Western world, is their recently increased social significance. Historically most of modern occultism is anything but new. From the research and theorizing about the occult revival we have picked up some main themes. The first is the social diffusion of the new occultism. In this field, we find some studies of superstition, especially astrology. These illuminate the differences in social connotation between the consumers of superstition and the followers of institutional religion. Secondly the study of the occult revival has made valuable contributions to the conceptualizing of "cult" and the cultic phenomenon. Thirdly, we will look upon the connection between the occult revival and the counter-culture. The problem of the rise of cults as a symptom of socio-cultural change will be briefly discussed with reference to Bell's thesis of "the disjuntion of culture and social structure". Lastly, we proffer some reflections on the occult revival and the new spiritual trends in the churches, which so sharply contrast with the theology and churchmanship of the sixties.

  20. Naturally occurring mutations in large surface genes related to occult infection of hepatitis B virus genotype C.

    Directory of Open Access Journals (Sweden)

    Hong Kim

    Full Text Available Molecular mechanisms related to occult hepatitis B virus (HBV infection, particularly those based on genotype C infection, have rarely been determined thus far in the ongoing efforts to determine infection mechanisms. Therefore, we aim to elucidate the mutation patterns in the surface open reading frame (S ORF underlying occult infections of HBV genotype C in the present study. Nested PCRs were applied to 624 HBV surface antigen (HBsAg negative Korean subjects. Cloning and sequencing of the S ORF gene was applied to 41 occult cases and 40 control chronic carriers. Forty-one (6.6% of the 624 Korean adults with HBsAg-negative serostatus were found to be positive for DNA according to nested PCR tests. Mutation frequencies in the three regions labeled here as preS1, preS2, and S were significantly higher in the occult subjects compared to the carriers in all cases. A total of two types of deletions, preS1 deletions in the start codon and preS2 deletions as well as nine types of point mutations were significantly implicated in the occult infection cases. Mutations within the "a" determinant region in HBsAg were found more frequently in the occult subjects than in the carriers. Mutations leading to premature termination of S ORF were found in 16 occult subjects (39.0% but only in one subject from among the carriers (2.5%. In conclusion, our data suggest that preS deletions, the premature termination of S ORF, and "a" determinant mutations are associated with occult infections of HBV genotype C among a HBsAg-negative population. The novel mutation patterns related to occult infection introduced in the present study can help to broaden our understanding of HBV occult infections.

  1. Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding

    Science.gov (United States)

    Hagopian, John; Lyon, Richard; Shiri, Shahram; Roman, Patrick

    2011-01-01

    Advanced formation flying occulter designs utilize a large occulter mask flying in formation with an imaging telescope to block and null starlight to allow imaging of faint planets in exosolar systems. A paper describes the utilization of subscale reflective occultation masks to evaluate formation flying occulter designs. The use of a reflective mask allows mounting of the occulter by conventional means and simplifies the test configuration. The innovation alters the test set-up to allow mounting of the mask using standard techniques to eliminate the problems associated with a standard configuration. The modified configuration uses a reflective set-up whereby the star simulator reflects off of a reflective occulting mask and into an evaluation telescope. Since the mask is sized to capture all rays required for the imaging test, it can be mounted directly to a supporting fixture without interfering with the beam. Functionally, the reflective occultation mask reflects light from the star simulator instead of transmitting it, with a highly absorptive carbon nanotube layer simulating the occulter blocking mask. A subscale telescope images the star source and companion dim source that represents a planet. The primary advantage of this is that the occulter can be mounted conventionally instead of using diffractive wires or magnetic levitation.

  2. The urine marker test

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Jensen, Stine Nylandsted; Elsborg, Peter

    2016-01-01

    BACKGROUND: Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured...... that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs......) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. OBJECTIVE: The objective of this study was to investigate the use of the urine marker during urine doping control testing. METHODS: Two studies investigated athletes' acceptance...

  3. McDonald's and the Occult.

    Science.gov (United States)

    Singer, Barry

    1979-01-01

    Discusses "occult" and "paranormal" literature which is often mistaken for nonfiction. Suggests that most publishers are unwilling to publish scientific perspectives on the paranormal because such writings would be unmarketable. Journal availability: see SO 507 190. (KC)

  4. Simultaneous pentafluorobenzyl derivatization and GC-ECNICI-MS measurement of nitrite and malondialdehyde in human urine: Close positive correlation between these disparate oxidative stress biomarkers.

    Science.gov (United States)

    Hanff, Erik; Eisenga, Michele F; Beckmann, Bibiana; Bakker, Stephan J L; Tsikas, Dimitrios

    2017-02-01

    Urinary nitrite and malondialdehyde (MDA) are biomarkers of nitrosative and oxidative stress, respectively. At physiological pH values of urine and plasma, nitrite and MDA exist almost entirely in their dissociated forms, i.e., as ONO - (ONOH, pK a =3.4) and - CH(CHO) 2 (CH 2 (CHO) 2 , pK a =4.5). Previously, we reported that nitrite and MDA react with pentafluorobenzyl (PFB) bromide (PFB-Br) in aqueous acetone. Here, we report on the simultaneous derivatization of nitrite and MDA and their stable-isotope labeled analogs O 15 NO - (4μM) and CH 2 (CDO) 2 (1μM or 10μM) with PFB-Br (10μL) to PFBNO 2 , PFB 15 NO 2 , C(PFB) 2 (CHO) 2 ), C(PFB) 2 (CDO) 2 by heating acetonic urine (urine-acetone, 100:400μL) for 60min at 50°C. After acetone evaporation under a stream of nitrogen, derivatives were extracted with ethyl acetate (1mL). A 1-μL aliquot of the ethyl acetate phase dried over anhydrous Na 2 SO 4 was injected in the splitless mode for simultaneous GC-MS analysis in the electron capture negative-ion chemical ionization mode. Quantification was performed by selected-ion monitoring (SIM) the anions [M-PFB] - m/z 46 for ONO - , m/z 47 for O 15 NO - , m/z 251 for - C(PFB)(CHO) 2 , and m/z 253 for - C(PFB)(CDO) 2 . The retention times were 3.18min for PFB-ONO 2 /PFB-O 15 NO 2 , and 7.13min for - C(PFB)(CHO) 2 / - C(PFB)(CDO) 2 . Use of CH 2 (CDO) 2 at 1μM but not at 10μM was associated with an unknown interference with the C(PFB) 2 (CDO) 2 peak. Endogenous MDA can be quantified using O 15 NO - (4μM) and CH 2 (CDO) 2 (10μM) as the internal standards. The method is also useful for the measurement of nitrate and creatinine in addition to nitrite and MDA. Nitrite and MDA were measured by this method in urine of elderly healthy subjects (10 females, 9 males; age, 60-70 years; BMI, 25-30kg/m 2 ). Creatinine-corrected excretion rates did not differ between males and females for MDA (62.6 [24-137] vs 80.2 [52-118]nmol/mmol, P=0.448) and for nitrite (102 [71-174] vs

  5. Optical performance of the New Worlds Occulter

    Science.gov (United States)

    Arenberg, Jonathan W.; Lo, Amy S.; Glassman, Tiffany M.; Cash, Webster

    2007-04-01

    The New Worlds Observer (NWO) is a multiple spacecraft mission that is capable of detecting and characterizing extra-solar planets and planetary systems. NWO consists of an external occulter and a generic space telescope, flying in tandem. The external occulter has specific requirements on its shape and size, while the telescope needs no special modification beyond that required to do high-quality astrophysical observations. The occulter is a petal-shaped, opaque screen that creates a high-suppression shadow large enough to accommodate the telescope. This article reports on the optical performance of the novel New Worlds occulter design. It also introduces two new aspects of its optical performance which enhance the detectability of extra-solar planets. We also include a brief discussion of the buildability and the tolerances of the occulter. It is also shown that an occulter design can be found for any set of science requirements. We show that NWO is a viable mission concept for the study of extra-solar planets. To cite this article: J.W. Arenberg et al., C. R. Physique 8 (2007).

  6. Prediction of occult hepatitis B virus infection in liver transplant donors through hepatitis B virus blood markers.

    Science.gov (United States)

    Tandoi, Francesco; Caviglia, Gian Paolo; Pittaluga, Fabrizia; Abate, Maria Lorena; Smedile, Antonina; Romagnoli, Renato; Salizzoni, Mauro

    2014-11-01

    Occult hepatitis B virus infection is defined as detectable HBV-DNA in liver of HBsAg-negative individuals, with or without detectable serum HBV-DNA. In deceased liver donors, results of tissue analysis cannot be obtained prior to allocation for liver transplantation. we investigated prevalence and predictability of occult hepatitis B using blood markers of viral exposure/infection in deceased liver donors. In 50 consecutive HBsAg-negative/anti-HBc-positive and 20 age-matched HBsAg-negative/anti-HBc-negative donors, a nested-PCR assay was employed in liver biopsies for diagnosis of occult hepatitis B according to Taormina criteria. All donors were characterized for plasma HBV-DNA and serum anti-HBs/anti-HBe. In liver tissue, occult hepatitis B was present in 30/50 anti-HBc-positive (60%) and in 0/20 anti-HBc-negative donors (pdonors with detectable HBV-DNA in plasma (n=5) or anti-HBs>1,000 mIU/mL (n=5) eventually showed occult infection, i.e, 10/30 occult hepatitis B-positive donors which could have been identified prior to transplantation. In the remaining 40 anti-HBc-positive donors, probability of occult infection was 62% for anti-HBe-positive and/or anti-HBs ≥ 58 mIU/mL; 29% for anti-HBe-negative and anti-HBsdonors, combining anti-HBc with other blood markers of hepatitis B exposure/infection allows to predict occult hepatitis B with certainty and speed in one third of cases. These findings might help refine the allocation of livers from anti-HBc-positive donors. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  7. Prevalence of occult hepatitis B virus infection in haemodialysis patients from central Greece

    Science.gov (United States)

    Mina, Paraskevi; Georgiadou, Sarah P; Rizos, Christos; Dalekos, George N; Rigopoulou, Eirini I

    2010-01-01

    AIM: To assess the hepatitis B virus (HBV)-DNA and the prevalence of occult HBV infection in end-stage renal failure (ESRF) patients from Central Greece. METHODS: Sera from 366 ESRF patients attending five out of six dialysis units from Central Greece were investigated for HBV-DNA by real-time polymerase chain reaction. Only serum samples with repeatedly detectable HBV-DNA were considered positive. IgG antibodies to hepatitis C virus (anti-HCV) were tested by a third generation enzyme linked immunosorbent assay (ELISA), while IgG antibodies to hepatitis E virus (anti-HEV) were tested by two commercially available ELISAs. RESULTS: HBV-DNA was detected in 15/366 patients (4.1%) and HBsAg in 20/366 (5.5%). The prevalence of occult HBV infection was 0.9% (3/346 HBsAg-negative patients). Occult HBV was not associated with a specific marker of HBV infection or anti-HCV or anti-HEV reactivity. There was no significant difference in HBV-DNA titres, demographic and biochemical features, between patients with occult HBV infection and those with HBsAg-positive chronic HBV infection. CONCLUSION: In central Greece, 4% of ESRF patients had detectable HBV-DNA, though in this setting, the prevalence of occult HBV seems to be very low (0.9%). PMID:20066742

  8. The value of MR imaging of PDFASAT sequence in the diagnosis of extremities occult fractures

    International Nuclear Information System (INIS)

    Lu Lingquan; Xu Mingshen; Wu Qianzhi; Mao Chunnan; Wang Shuzi; Zhou Xingfan; Wang Liping

    2004-01-01

    Objective: To investigate the value of MR imaging of proton density weighted-fat saturated (PDFASAT) sequence in detecting the occult fracture of extremities. Methods: Thirty-one patients with acute trauma were studied using radiography and MR imaging within 45 days. MR sequences included FSE T 1 WI, T 2 WI, and PDFASAT. 21 occult fractures occurred in the knee joint, 6 in the hip joint, 1 in the elbow joint, 2 in the shoulder, and 1 in the ankle. Results: All 31 cases had normal radiographic results. 10 cases with proximal fibula, 4 with proximal tibia and 7 with femur condyle occult fractures were found in 21 knee joint acute trauma cases. 2 cases with intertrochanteric, 2 with femoral neck and 2 with cotyle occult fractures were found in 6 hip joint trauma cases. 2 proximal humerus occult fractures were found in 2 shoulder cases. 1 distal humerus and 1 distal fibula occult fracture was found in elbow and ankle cases. MR imaging demonstrated irregular linear low signal in the subcortical region on both T 1 WI and T 2 WI, and high signal changes around low signal were seen on T 2 WI in some cases. The high signal in PDFASAT sequence was more remarkable and wider than that on both T 1 WI and T 2 WI. Conclusion: MR imaging could determine the diagnosis of acute and chronic occult fractures. MRI should be the next choice when plain films fail to reveal suspected fractures in setting of suggestive symptoms and positive physical examination. PDFASAT would be the best effective sequence among the T 1 WI, T 2 WI, and PDFASAT. (author)

  9. Urine specific gravity test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  10. Maple syrup urine disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000373.htm Maple syrup urine disease To use the sharing features on this page, please enable JavaScript. Maple syrup urine disease (MSUD) is a disorder in ...

  11. Urine drug screen

    Science.gov (United States)

    Drug screen - urine ... detect the presence of illegal and some prescription drugs in your urine. Their presence may indicate that you recently used these drugs. Some drugs may remain in your system for ...

  12. Urine Tests (For Parents)

    Science.gov (United States)

    ... the urine sample. In certain situations, a sterile bag can be placed around a baby’s diaper area to collect a urine sample. If you have any questions about urine tests, talk with your doctor. Reviewed by: Yamini Durani, MD ...

  13. Outcome of Concurrent Occult Hemothorax and Pneumothorax in Trauma Patients Who Required Assisted Ventilation

    Directory of Open Access Journals (Sweden)

    Ismail Mahmood

    2015-01-01

    Full Text Available Background. The management and outcomes of occult hemopneumothorax in blunt trauma patients who required mechanical ventilation are not well studied. We aimed to study patients with occult hemopneumothorax on mechanical ventilation who could be carefully managed without tube thoracostomy. Methods. Chest trauma patients with occult hemopneumothorax who were on mechanical ventilation were prospectively evaluated. The presence of hemopneumothorax was confirmed by CT scanning. Hospital length of stay, complications, and outcome were recorded. Results. A total of 56 chest trauma patients with occult hemopneumothorax who were on ventilatory support were included with a mean age of 36 ± 13 years. Hemopneumothorax was managed conservatively in 72% cases and 28% underwent tube thoracostomy as indicated. 29% of patients developed pneumonia, 16% had Acute Respiratory Distress Syndrome (ARDS, and 7% died. Thickness of hemothorax, duration of mechanical ventilation, and development of ARDS were significantly associated with tube thoracostomy in comparison to no-chest tube group. Conclusions. The majority of occult hemopneumothorax can be carefully managed without tube thoracostomy in patients who required positive pressure ventilation. Tube thoracotomy could be restricted to those who had evidence of increase in the size of the hemothorax or pneumothorax on follow-up chest radiographs or developed respiratory compromise.

  14. Strong scintillations during atmospheric occultations Theoretical intensity spectra. [radio scattering during spacecraft occultations by planetary atmospheres

    Science.gov (United States)

    Hinson, D. P.

    1986-01-01

    Each of the two Voyager spacecraft launched in 1977 has completed a reconnaissance of the Jovian and Saturnian systems. In connection with occultation experiments, strong scintillations were observed. Further theoretical work is required before these scintillations can be interpreted. The present study is, therefore, concerned with the derivation of a theory for strong scattering during atmospheric occultation experiments, taking into account as fundamental quantity of interest the spatial spectrum (or spectral density) of intensity fluctuations. Attention is given to a theory for intensity spectra, and numerical calculations. The new formula derived for Phi-i accounts for strong scattering of electromagnetic waves during atmospheric occultations.

  15. First results from stellar occultations in the "GAIA era"

    Science.gov (United States)

    Benedetti-Rossi, G.; Vieira-Martins, R.; Sicardy, B.

    2017-09-01

    Stellar occultation is a powerful technique to study distant solar system bodies. It allows high angular resolution of the occulting body from the analysis of a light curve acquired with high temporal resolution with uncertainties comparable as probes. In the "GAIA era", stellar occultations is now able to obtain even more impressive results such as the presence of atmosphere, rings and topographic features.

  16. Earlier stages of colorectal cancer detected with immunochemical faecal occult blood tests

    NARCIS (Netherlands)

    van Rossum, L. G. M.; van Rijn, A. F.; van Munster, I. P.; Jansen, J. B. M. J.; Fockens, P.; Laheij, R. J. F.; Dekker, E.

    2009-01-01

    Background: The aim of colorectal cancer screening is to improve prognosis by the detection of early cancer and precursor stages. We compared the stage distribution of asymptomatic colorectal cancer patients detected by a positive immunochemical or guaiac-based faecal occult blood test (FOBT) with

  17. External occulter edge scattering control using metamaterials for exoplanet detection

    Science.gov (United States)

    Bendek, Eduardo A.; Sirbu, Dan; Liu, Zhaowei; Martin, Stefan; Lu, Dylan

    2015-09-01

    Direct imaging of earth-like exoplanets in the Habitable Zone of sun-like stars requires image contrast of ~10^10 at angular separations of around a hundred milliarcseconds. One approach for achieving this performance is to fly a starshade at a long distance in front of the telescope, shading the telescope from the direct starlight, but allowing planets around the star to be seen. The starshade is positioned so that sunlight falls on the surface away from the telescope, so the sun does not directly illuminate it. However, sunlight scattered from the starshade edge can enter the telescope, raising the background light level and potentially preventing the starshade from delivering the required contrast. As a result, starshade edge design has been identified as one of the highest priority technology gaps for external occulter missions in the NASAs Exoplanet Exploration Program Technology Plan 2013. To reduce the sunlight edge scatter to an acceptable level, the edge Radius Of Curvature (ROC) should be 1μm or less (commercial razor blades have ROC of a few hundred nanometer). This poses a challenging manufacturing requirement and may make the occulter difficult to handle. In this paper we propose an alternative approach to controlling the edge scattering by applying a flexible metamaterial to the occulter edge. Metamaterials are artificially structured materials, which have been designed to display properties not found in natural materials. Metamaterials can be designed to direct the scatter at planned incident angles away from the space telescope, thereby directly decreasing the contaminating background light. Reduction of the background light translates into shorter integration time to characterize a target planet and therefore improves the efficiency of the observations. As an additional benefit, metamaterials also have potential to produce increased tolerance to edge defects.

  18. Occult spondyloarthritis in inflammatory bowel disease.

    Science.gov (United States)

    Bandinelli, Francesca; Manetti, Mirko; Ibba-Manneschi, Lidia

    2016-02-01

    Spondyloarthritis (SpA) is a frequent extra-intestinal manifestation in patients with inflammatory bowel disease (IBD), although its real diffusion is commonly considered underestimated. Abnormalities in the microbioma and genetic predisposition have been implicated in the link between bowel and joint inflammation. Otherwise, up to date, pathogenetic mechanisms are still largely unknown and the exact influence of the bowel activity on rheumatic manifestations is not clearly explained. Due to evidence-based results of clinical studies, the interest on clinically asymptomatic SpA in IBD patients increased in the last few years. Actually, occult enthesitis and sacroiliitis are discovered in high percentages of IBD patients by different imaging techniques, mainly enthesis ultrasound (US) and sacroiliac joint X-ray examinations. Several diagnostic approaches and biomarkers have been proposed in an attempt to correctly classify and diagnose clinically occult joint manifestations and to define clusters of risk for patient screening, although definitive results are still lacking. The correct recognition of occult SpA in IBD requires an integrated multidisciplinary approach in order to identify common diagnostic and therapeutic strategies. The use of inexpensive and rapid imaging techniques, such as US and X-ray, should be routinely included in daily clinical practice and trials to correctly evaluate occult SpA, thus preventing future disability and worsening of quality of life in IBD patients.

  19. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  20. Derivatization of carboxylic acids with 4-APEBA for detection by positive-ion LC-ESI-MS(/MS) applied for the analysis of prostanoids and NSAID in urine

    NARCIS (Netherlands)

    Kretschmer, A.; Giera, M.A.; Wijtmans, M.; de Vries, L.; Lingeman, H.; Irth, H.; Niessen, W.M.A.

    2011-01-01

    In order to develop a generic positive ionization ESI LC-MS method for a variety of interesting substance classes, a new derivatization strategy for carboxylic acids was developed. The carboxylic acid group is labeled with the bromine containing 4-APEBA reagent based on carbodiimide chemistry. The

  1. Incremento de los urocultivos positivos en un hospital de cuarto nivel de atención Increment in positive urine cultures in a fourth level attention hospital

    Directory of Open Access Journals (Sweden)

    JAIME ALBERTO LÓPEZ

    2006-03-01

    interventions with respect to the use of screening tests increases the proportion of positive urocultures, in comparison with the absence of using these interventions. Design: The study is a prospective, analytical study. Place: Hospital Pablo Tobón Uribe, Medellín, Colombia. Population: 25.766 urocultures obtained from 1998 to 2005. Methods: some educative and administrative actions were taken to increase the positivity of the requestes urocultures. All data from ordered urocultures were registered. The ordered Gram stains in hospitalized patients and patients who attended the emergency unit that were hospitalized, the positive urocultures of the recommended ones, those requested directly by the medical practitioners, and services. Results: Gram stain percentage without centrifugation for uroculture in hospitalized patients increased from 0.7% in 1998 to 32.1% in 2005 ( p = 0.000. Urocultures were positive in 79.4% of the cases when they were done by laboratory recommendation, whereas positivity of directly requested cultures was of 27.9% ( p = 0.000. The total percentage of positive urocultures in 1998 for hospitalized patients was 29.7%, and in 1999-2005 was 40.3% ( c² = 74.95; p = 0.000, period when the microbiology laboratory intervened actively. Positive urocultures from requested for adult and pediatric emergency patients increased from 34% and 15% in 1998 to 66% and 30% in 2005, respectively; in other hospitalization services the percentage increased from 26% to 40%. Conclusions: The percentage of positive urocultures may increase if the knowledge derived from the study of the corresponding screening tests is applied to the clinical practice.

  2. Calcium in Urine Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  3. Occult hepatitis B virus among the patients with abnormal alanine transaminase.

    Science.gov (United States)

    Makvandi, Manoochehr; Neisi, Niloofar; Khalafkhany, Davod; Makvandi, Kamyar; Hajiani, Eskandar; Shayesteh, Ali Akbar; Masjedi Zadeh, Abdolrahim; Sina, Amir Hosein; Hamidifard, Mojtaba; Rasti, Mojtaba; Aryan, Ehsan; Ahmadi, Kambiz; Yad Yad, Mohammad Jafar

    2014-08-01

    The occult hepatitis B infection (OBI) is defined as the presence of hepatitis B virus (HBV) DNA in the sera or in the liver biopsy and the absence of hepatitis B surface antigen (HBsAg) by serological test. The current study aimed to evaluate the occult HBV infection by polymerase chain reaction (PCR) and determine HBV genotyping among the patients with abnormal alanine transaminase (ALT) in Ahvaz city, Iran. The sera of 120 patients, 54 (45%) females and 66 (55%) males, with abnormal ALT 40-152 IU were collected. All the patients were negative for HBsAg for more than one year. The patients` sera were tested by PCR using primers specified for the S region of HBV. Then the positive PCR products were sequenced to determine HBV genotyping and phylogenic tree. Of these 120 subjects, 12 (10%) patients including 6 (5%) males and 6 (5%) females were found positive for HBV DNA by PCR, which indicated the presence of occult HBV infection among these patients. The sequencing results revealed that genotype D was predominant with sub-genotyping D1 among OBI patients. Occult hepatitis B infection is remarkably prevalent in Ahvaz, Iran, and should be considered as a potential risk factor for the transmission of Hepatitis B Virus throughout the community by the carriers.

  4. Occult Hepatitis B Virus Among the Patients With Abnormal Alanine Transaminase

    Science.gov (United States)

    Makvandi, Manoochehr; Neisi, Niloofar; Khalafkhany, Davod; Makvandi, Kamyar; Hajiani, Eskandar; Shayesteh, Ali Akbar; Masjedi Zadeh, Abdolrahim; Sina, Amir Hosein; Hamidifard, Mojtaba; Rasti, Mojtaba; Aryan, Ehsan; Ahmadi, Kambiz; Yad Yad, Mohammad Jafar

    2014-01-01

    Background: The occult hepatitis B infection (OBI) is defined as the presence of hepatitis B virus (HBV) DNA in the sera or in the liver biopsy and the absence of hepatitis B surface antigen (HBsAg) by serological test. Objectives: The current study aimed to evaluate the occult HBV infection by polymerase chain reaction (PCR) and determine HBV genotyping among the patients with abnormal alanine transaminase (ALT) in Ahvaz city, Iran. Patients and Methods: The sera of 120 patients, 54 (45%) females and 66 (55%) males, with abnormal ALT 40-152 IU were collected. All the patients were negative for HBsAg for more than one year. The patients` sera were tested by PCR using primers specified for the S region of HBV. Then the positive PCR products were sequenced to determine HBV genotyping and phylogenic tree. Results: Of these 120 subjects, 12 (10%) patients including 6 (5%) males and 6 (5%) females were found positive for HBV DNA by PCR, which indicated the presence of occult HBV infection among these patients. The sequencing results revealed that genotype D was predominant with sub-genotyping D1 among OBI patients. Conclusions: Occult hepatitis B infection is remarkably prevalent in Ahvaz, Iran, and should be considered as a potential risk factor for the transmission of Hepatitis B Virus throughout the community by the carriers. PMID:25485052

  5. Influence of Ionospheric Weather on GNSS Radio Occultation Signals

    Science.gov (United States)

    Yue, X.; Schreiner, W. S.; Pedatella, N. M.; Kuo, Y. H.

    2016-12-01

    Transient loss of lock (LOL) is one of the key space weather effects on the Global Navigation Satellite System (GNSS). Based on the Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC) Global Positioning System (GPS) radio occultation (RO) observations during 2007-2011, we have analyzed the signal cycle slip (CS) occurrence comprehensively and its correlation to the ionospheric weather phenomena such as sporadic E (Es), equatorial F region irregularity (EFI), and the ionospheric equatorial ionization anomaly (EIA). The high vertical resolution of RO observations enables us to distinguish the CS resulting from different ionospheric layers clearly on a global scale. In the E layer, the CS is dominated by the Es occurrence, while in the F layer, the CS is mainly related to the EIA and EFI at low and equatorial latitudes. In the polar region, the CS is primarily related to polar cap electron density gradients. The overall average CS (> 6 cycles) occurrence is 23% per occultation, with the E (50-150 km) and F (150-600 km) layers contributing 8.3% and 14.7%, respectively. Awareness of the effect of the ionospheric weather on the CS of the low-Earth-orbit (LEO)-based GNSS signal could be beneficial to a variety of applications, including the LEO-based GNSS data processing and the corresponding hardware/firmware design.

  6. Occulting Light Concentrators in Liquid Scintillator Neutrino Detectors

    Science.gov (United States)

    Buizza Avanzini, Margherita; Cabrera, Anatael; Dusini, Stefano; Grassi, Marco; He, Miao; Wu, Wenjie

    2017-09-01

    The experimental efforts characterizing the era of precision neutrino physics revolve around collecting high-statistics neutrino samples and attaining an excellent energy and position resolution. Next generation liquid-based neutrino detectors, such as JUNO, HyperKamiokande, etc, share the use of a large target mass, and the need of pushing light collection to the edge for maximal calorimetric information. Achieving high light collection implies considerable costs, especially when considering detector masses of several kt. A traditional strategy to maximize the effective photo-coverage with the minimum number of PMTs relies on Light Concentrators (LC), such as Winston Cones. In this paper, the authors introduce a novel concept called Occulting Light Concentrators (OLC), whereby a traditional LC gets tailored to a conventional PMT, by taking into account its single-photoelectron collection efficiency profile and thus occulting the worst performing portion of the photocathode. Thus, the OLC shape optimization takes into account not only the optical interface of the PMT, but also the maximization of the PMT detection performances. The light collection uniformity across the detector is another advantage of the OLC system. By considering the case of JUNO, we will show OLC capabilities in terms of light collection and energy resolution.

  7. Occult diaphragmatic injuries caused by stab wounds.

    Science.gov (United States)

    Leppäniemi, Ari; Haapiainen, Reijo

    2003-10-01

    Missed diaphragmatic perforation caused by penetrating trauma can lead to subsequent strangulation of a hollow viscus, which has prompted the use of invasive diagnostic procedures to exclude occult diaphragmatic injuries in asymptomatic, high-risk patients. The objective of this study was to determine the incidence of occult diaphragmatic injuries caused by stab wounds of the lower chest and upper abdomen, and to examine the natural history and consequences of missed diaphragmatic injuries. On the basis of patient data from two previous randomized studies from our institution, a retrospective analysis was performed on 97 patients treated for anterior stab wounds located between the nipple line, the umbilical level, and the posterior axillary lines not having indications for immediate surgical exploration. The patients were divided into two groups on the basis of their initial randomized management (open or laparoscopic exploration vs. expectant observation). In the exploration group (n = 47), four diaphragmatic injuries (9%) were detected (three left-sided and one right-sided). Excluding patients with associated injuries requiring surgical repair, the incidence of occult diaphragmatic injuries was 3 of 43 (7%). In the observation group (n = 50), there were two patients (4%) with delayed presentation of missed left-sided diaphragmatic injury 2 and 23 months later, respectively. Both injuries resulted from stab wounds of the left flank and presented with herniation of the stomach or small bowel and colon. The overall incidence of occult diaphragmatic injuries in left-sided thoracoabdominal stab wounds was 4 of 24 (17%), and was much lower after stab wounds of left epigastrium (0%), right lower chest (0%), and right epigastrium (4%). In asymptomatic patients with anterior or flank stab wounds of the lower chest or upper abdominal area, the risk of an occult diaphragmatic injury is approximately 7% which, if undetected, is associated with a high risk of subsequent

  8. Pink urine syndrome

    Directory of Open Access Journals (Sweden)

    Luis del Carpio-Orantes

    2017-03-01

    Full Text Available In the present images we allude to a syndrome of low incidence, characterized by pink urine, being related to factors such as obesity, and being triggered by abdominal surgeries, use of propofol, among others. Being favoured by the presence of abundant crystals of uric acid in the urine confers the typical pink coloration.

  9. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  10. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  11. Paraneoplastic retinopathy associated with occult bladder cancer

    DEFF Research Database (Denmark)

    Nivean, M; Muttuvelu, Danson V; Afzelius, Pia Maria Tullia

    2016-01-01

    (ERG), serology including serum antibodies for CAR, and positron emission tomography-computed tomography (PET-CT) scan. The patient was diagnosed with bladder carcinoma revealed by PET-CT. Timely recognition of this entity may be crucial for an increased patient survival thus adult onset progressive...... photoreceptor dysfunction, confirmed by ERG, should alert to a possible remote effect of known or occult malignancy. In the latter, PET-CT may be exploited as a powerful diagnostic tool....

  12. Results from occultations by minor planets

    International Nuclear Information System (INIS)

    Taylor, G.E.

    1982-01-01

    Since the minor planets are believed to consist of primordial matter dating from the time of the formation of the solar system there is great interest in determining their composition. It is therefore necessary to calculate their densities, for which we need accurate masses and sizes. On the rare occasions when a minor planet occults a star, timed observations of the event from a number of observing sites enable an accurate size of the minor planet to be determined. (Auth.)

  13. ASTEROID SIZING BY RADIOGALAXY OCCULTATION AT 5 GHZ

    Energy Technology Data Exchange (ETDEWEB)

    Lehtinen, K.; Muinonen, K.; Poutanen, M. [Finnish Geospatial Research Institute FGI, Geodeetinrinne 2, FI-02430 Masala (Finland); Bach, U. [Max-Planck-Institut für Radioastronomie, Radioobservatorium Effelsberg, Max-Planck-Str. 28, D-53902 Bad Münstereifel-Effelsberg (Germany); Petrov, L., E-mail: kimmo.lehtinen@nls.fi [Astrogeo Center, Falls Church, VA 22043 (United States)

    2016-05-10

    Stellar occultations by asteroids observed at visual wavelengths have been an important tool for studying the size and shape of asteroids and for revising the orbital parameters of asteroids. At radio frequencies, a shadow of an asteroid on the Earth is dominated by diffraction effects. Here, we show, for the first time, that a single observation of an occultation of a compact radio source at a frequency of 5 GHz can be used to derive the effective size of the occulting object and to derive the distance between the observer and the center of the occultation path on the Earth. The derived diameter of the occulting object, asteroid (115) Thyra, is 75 ± 6 km. The observed occultation profile shows features that cannot be explained by diffraction of a single asteroid.

  14. OCCULTISM AND MEDIUMSHIP IN FERNANDO PESSOA

    Directory of Open Access Journals (Sweden)

    Alisson Diêgo Dias de Medeiros

    2016-03-01

    Full Text Available This work is the result of a research on the influence that the occultism had on the work of the Portuguese poet Fernando Pessoa. To delimitate the study, we selected papers of Fernando Pessoa, which  suggested that the poet considered himself medium, and hence influenced his work, building his depersonalization. This work presents, thus, as main objectiveto analyze personal papers of Fernando Pessoa, whose outstanding characteristic is the presence of occultism and the supposed mediumship defended by him in response to non-literary and heteronymic manifestations. To this end, I focused on specific objectives, which are: a to study the speech of Fernando Pessoa on his supposed mediumship / occultism b to analyze specific texts that are, for the poet, mediumistic manifestations c to study excerpts from a set of personal letters in which Fernando Pessoa suggested being a medium. It is true that this dissertation will address many discussions already made by scholars and specialists in Fernando Pessoa, but we consider the possibility to deepen issues and contribute to the critical fortune of the poet.

  15. Stellar Occultations by TNOs and Centaurs: first results in the “Gaia era”

    Science.gov (United States)

    Rossi, Gustavo; Vieira-Martins, Roberto; Sicardy, Bruno; Ortiz, Jose Luis; Rio Group, Lucky Star Occultation Team, Granada Occultation Team

    2017-10-01

    After the first release of the GAIA catalog (in September/2016), stellar positions are now known with unprecedented accuracy, reaching values of the order of milliarcseconds. This improvement reflected into a stunning accuracy on the astrometry of moving objects, such as TNOs. Unfortunately, Gaia stars proper motions will be only available on the second data release (DR2) next year, so there is still a need to use hybrid stellar catalogs for occultation predictions until then. Despite that, stellar occultations predictions are now much more accurate, and the biggest uncertainties comes mainly from the object ephemerides. This issue will be overcome by large surveys such as the LSST, which will provide positions for the known TNOs and it is expected to increase the number of known TNOs by nearly 40,000, with an unprecedent amount of acquired information.This huge amount of data also poses a new era in stellar occultations: predictions will be very accurate and the participation of professional astronomers, laboratories, and the amateur community will be crucial to observe the predicted events; observation campaigns will need to be selected according to a specific scientific purpose such as the probability to detect rings or archs around a body, the presence of atmosphere or even the detection of topographic features; the development of softwares capable of reducing the data more efficiently and an easier method to coordinate observation campaigns are needed.Here we present some impressive results obtained from predictions and observed occultations in 2017 (among them we have Pluto, Chariklo and Haumea), the problems we are starting to face in the beginning of the “Gaia era” and the future challenges of stellar occultation.

  16. Estimation and evaluation of COSMIC radio occultation excess phase using undifferenced measurements

    Science.gov (United States)

    Xia, Pengfei; Ye, Shirong; Jiang, Kecai; Chen, Dezhong

    2017-05-01

    In the GPS radio occultation technique, the atmospheric excess phase (AEP) can be used to derive the refractivity, which is an important quantity in numerical weather prediction. The AEP is conventionally estimated based on GPS double-difference or single-difference techniques. These two techniques, however, rely on the reference data in the data processing, increasing the complexity of computation. In this study, an undifferenced (ND) processing strategy is proposed to estimate the AEP. To begin with, we use PANDA (Positioning and Navigation Data Analyst) software to perform the precise orbit determination (POD) for the purpose of acquiring the position and velocity of the mass centre of the COSMIC (The Constellation Observing System for Meteorology, Ionosphere and Climate) satellites and the corresponding receiver clock offset. The bending angles, refractivity and dry temperature profiles are derived from the estimated AEP using Radio Occultation Processing Package (ROPP) software. The ND method is validated by the COSMIC products in typical rising and setting occultation events. Results indicate that rms (root mean square) errors of relative refractivity differences between undifferenced and atmospheric profiles (atmPrf) provided by UCAR/CDAAC (University Corporation for Atmospheric Research/COSMIC Data Analysis and Archive Centre) are better than 4 and 3 % in rising and setting occultation events respectively. In addition, we also compare the relative refractivity bias between ND-derived methods and atmPrf profiles of globally distributed 200 COSMIC occultation events on 12 December 2013. The statistical results indicate that the average rms relative refractivity deviation between ND-derived and COSMIC profiles is better than 2 % in the rising occultation event and better than 1.7 % in the setting occultation event. Moreover, the observed COSMIC refractivity profiles from ND processing strategy are further validated using European Centre for Medium

  17. OCCULT-ORSER complete conversational user-language translator

    Science.gov (United States)

    Ramapriyan, H. K.; Young, K.

    1981-01-01

    Translator program (OCCULT) assists non-computer-oriented users in setting up and submitting jobs for complex ORSER system. ORSER is collection of image processing programs for analyzing remotely sensed data. OCCULT is designed for those who would like to use ORSER but cannot justify acquiring and maintaining necessary proficiency in Remote Job Entry Language, Job Control Language, and control-card formats. OCCULT is written in FORTRAN IV and OS Assembler for interactive execution.

  18. Urine Concentration and Pyuria for Identifying UTI in Infants.

    Science.gov (United States)

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  19. Usefullness of routine use of fecal occult blood test in a hospital setting

    Directory of Open Access Journals (Sweden)

    Simona Ravnik

    2006-12-01

    Full Text Available Background: Fecal occult blood test, hematest, is a well excepted non-invasive method used for detecting different diseases of the gastrointestinal tract. It was proven in different randomized studies that usage of this simple method may facilitate further diagnostic and therapeutic treatment.Patients and methods: The retrospective analysis includes patients, which were admitted to the gastroenterological and endoscopy department of the General hospital Maribor in the last quarter of the year 2005. In all patients fecal occult blood test was performed.Results: We examined 200 patients, 104 women and 96 men, average age 63.9 years, SD±16.9, ranging from 21 to 97 years. Positive hematest was discovered in 76 patients (38 %. The source of hemorrhage from the upper digestive tract was confirmed in 37 patients (48.6 % of all positive tests and from the lower digestive tract in 34 patients (46 % of all positive tests. The most frequent causes of hemorrhage from the lower digestive tract were chronic inflammatory bowel disease (13.1 % of all positive tests, colorectal cancer (10.5 % and polyps (6.6 %. The source of hemorrhage was not located in five patients (6.6 % of all positive tests despite the accurate diagnostic procedure.Conclusions: By performing a fecal occult blood screening in non-symptomatic patients, we can make an essential step towards discovering different gastrointestinal diseases, even colorectal cancer in its early, limited form, when the effect of treatment is greatest.

  20. Management of occult stress urinary incontinence with prolapse surgery.

    Science.gov (United States)

    Al-Mandeel, H; Al-Badr, A

    2013-08-01

    Pelvic organ prolapse (POP) and stress urinary incontinence (SUI), are two common health-related conditions, each affecting up to 50% women worldwide. Stress urinary incontinence only observed after the reduction of co-existent prolapse is called occult SUI (OSUI), and is found in up to 80% of women with advanced POP. Although there is no consensus on how to diagnose OSUI, there are several reported methods to better diagnose. Counseling symptomatically continent women with POP concerning the potential risk for developing SUI postoperatively cannot be overstated. Evidence suggests that positive OSUI in symptomatically continent women who are planning to have POP repair is associated with a high risk of POSUI, furthermore, adding continence procedure is found to reduce postoperative SUI. Therefore, adding continence surgery at the time of POP surgery in patients who are found to have OSUI preoperatively is advocated.

  1. CT colonography in faecal occult blood test positives

    NARCIS (Netherlands)

    Liedenbaum, M.H.

    2010-01-01

    CT colonography is a non-invasive imaging technique to visualise the colon. The colon is insufflated with CO2 or air and a CT-scan of the abdomen is performed. The performance of CT colonography is nearly equal to that of colonoscopy in the detection of large colonic polyps and carcinomas. This

  2. Creatinine urine test

    Science.gov (United States)

    Urine creatinine test ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ... done to see how well your kidneys work. Creatinine is removed by the body entirely by the ...

  3. Urine protein electrophoresis test

    Science.gov (United States)

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  4. Uric acid - urine

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003616.htm Uric acid urine test To use the sharing features on ... are no risks with this test. Images Uric acid test Uric acid crystals References Burns CM, Wortmann RL. Clinical ...

  5. Purple Urine Bag Syndrome

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    sudden onset, progressive left sided weakness involving both upper and ... computed tomography of the brain showed right ... included a complete blood count, renal functions which were ... Urine culture had a significant growth of Klebsiella.

  6. Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum

    Science.gov (United States)

    Shiri, Ron Shahram; Wasylkiwskyj, Wasyl

    2013-01-01

    The presence of the Poisson Spot, also known as the spot of Arago, has been known since the 18th century. This spot is the consequence of constructive interference of light diffracted by the edge of the obstacle where the central position can be determined by symmetry of the object. More recently, many NASA missions require the suppression of this spot in the visible range. For instance, the exoplanetary missions involving space telescopes require telescopes to image the planetary bodies orbiting central stars. For this purpose, the starlight needs to be suppressed by several orders of magnitude in order to image the reflected light from the orbiting planet. For the Earth-like planets, this suppression needs to be at least ten orders of magnitude. One of the common methods of suppression involves sharp binary petaled occulters envisioned to be placed many thousands of miles away from the telescope blocking the starlight. The suppression of the Poisson Spot by binary sharp petal tips can be problematic when the thickness of the tips becomes smaller than the wavelength of the incident beam. First they are difficult to manufacture and also it invalidates the laws of physical optics. The proposed partially transparent petaled masks/occulters compensate for this sharpness with transparency along the surface of the petals. Depending on the geometry of the problem, this transparency can be customized such that only a small region of the petal is transparent and the remaining of the surface is opaque. This feature allows easy fabrication of this type of occultation device either as a mask or occulter. A partially transparent petaled mask/ occulter has been designed for the visible spectrum range. The mask/occulter can suppress the intensity along the optical axis up to ten orders of magnitude. The design process can tailor the mask shape, number of petals, and transparency level to the near-field and farfield diffraction region. The mask/occulter can be used in space

  7. Histopathological Parameters predicting Occult Nodal Metastases in Tongue Carcinoma Cases: An Indian Perspective.

    Science.gov (United States)

    Jacob, Tina Elizabeth; Malathi, N; Rajan, Sharada T; Augustine, Dominic; Manish, N; Patil, Shankargouda

    2016-01-01

    It is a well-established fact that in squamous cell carcinoma cases, the presence of lymph node metastases decreased the 5-year survival rate by 50% and also caused the recurrence of the primary tumor with development of distant metastases. Till date, the predictive factors for occult cervical lymph nodes metastases in cases of tongue squamous cell carcinoma remain inconclusive. Therefore, it is imperative to identify patients who are at the greatest risk for occult cervical metastases. This study was thus performed with the aim to identify various histopathologic parameters of the primary tumor that predict occult nodal metastases. The clinicopathologic features of 56 cases of lateral tongue squamous cell carcinoma with cT1NoMo/cT2NoMo as the stage and without prior radiotherapy or chemotherapy were considered. The surgical excision of primary tumor was followed by elective neck dissection. The glossectomy specimen along with the neck nodes were fixed in formalin and 5 urn thick sections were obtained. The hematoxylin & eosin stained sections were then subjected to microscopic examination. The primary tumor characteristics that were analyzed include tumor grade, invading front, depth of tumor, lymphovascular invasion, perineural invasion and inflammatory response. The nodes were examined for possible metastases using hematoxylin & eosin followed by cytokeratin immunohistochemistry. A total of 12 cases were found with positive occult nodal metastases. On performing univariate analysis, the histopathologic parameters that were found to be statistically significant were lymphovascular invasion (p = 0.004) and perineural invasion (p = 0.003) along with a cut-off depth of infiltration more than 5 mm (p = 0.01). Histopathologic assessment of the primary tumor specimen therefore continues to provide information that is central to guide clinical management, particularly in cases of occult nodal metastases. Clinical significance The study highlights the importance of

  8. Occult Pneumothoraces in Acute Trauma Patients

    Directory of Open Access Journals (Sweden)

    Chad Berryman

    2012-12-01

    Full Text Available Introduction: Many traumatic pneumothoraces (PTX are not seen on initial chest radiograph (CR(occult PTX but are detected only on computed tomography (CT. Although CR remains the first toolfor detecting PTX, most trauma patients with significant thoracoabdominal injuries will receive both CTand CR. The primary objective of this study was to retrospectively determine the effectiveness of CR fordetecting PTX in trauma patients. Our hypotheses were that CR is a sensitive indicator of PTX on CT,that chest pain and shortness of breath are good predictors of PTX on CR, and that we could determineother predictors of PTX on CR.Methods: All trauma patients presenting to our Level I trauma center with a CT-diagnosed PTX over a2-year period who had both a CR and a chest CT were included. The CT reading was considered thegold standard for PTX diagnosis. Electronic medical records were searched using key words fordiagnoses, symptoms, demographics, and radiologic results. We recorded the official radiologistreadings for both CR and CT (positive or negative and the size of the PTX on CT (large, moderate,small, or tiny. The outcome variable was dichotomized based on presence or absence of PTXdetected on CR. Descriptive statistics and v2 tests were used for univariate analysis. A regressionanalysis was performed to determine characteristics predictive of a PTX on CR, and 1 variable wasadded to the model for every 10 positive CRs. With equal-size groups, this study has the power of 80%to detect a 10% absolute difference in single predictors of PTX on CR with 45 subjects in each group.Results: There were 134 CT-documented PTXs included in the study. Mean age was 42, and 74%were men. For 66 (49% patients, PTX was detected on CR (sensitivity¼50%. The CR detected 30%of small PTX, 35% of moderate PTX, and 33% of large PTX. Comparing patients with and without PTXon CR, there were no significant differences in shortness of breath or chest pain. There no

  9. Occult pneumothoraces in acute trauma patients.

    Science.gov (United States)

    Ernst, Amy A; McIntyre, William A; Weiss, Steven J; Berryman, Chad

    2012-11-01

    Many traumatic pneumothoraces (PTX) are not seen on initial chest radiograph (CR) (occult PTX) but are detected only on computed tomography (CT). Although CR remains the first tool for detecting PTX, most trauma patients with significant thoracoabdominal injuries will receive both CT and CR. The primary objective of this study was to retrospectively determine the effectiveness of CR for detecting PTX in trauma patients. Our hypotheses were that CR is a sensitive indicator of PTX on CT, that chest pain and shortness of breath are good predictors of PTX on CR, and that we could determine other predictors of PTX on CR. All trauma patients presenting to our Level I trauma center with a CT-diagnosed PTX over a 2-year period who had both a CR and a chest CT were included. The CT reading was considered the gold standard for PTX diagnosis. Electronic medical records were searched using key words for diagnoses, symptoms, demographics, and radiologic results. We recorded the official radiologist readings for both CR and CT (positive or negative) and the size of the PTX on CT (large, moderate, small, or tiny). The outcome variable was dichotomized based on presence or absence of PTX detected on CR. Descriptive statistics and χ(2) tests were used for univariate analysis. A regression analysis was performed to determine characteristics predictive of a PTX on CR, and 1 variable was added to the model for every 10 positive CRs. With equal-size groups, this study has the power of 80% to detect a 10% absolute difference in single predictors of PTX on CR with 45 subjects in each group. There were 134 CT-documented PTXs included in the study. Mean age was 42, and 74% were men. For 66 (49%) patients, PTX was detected on CR (sensitivity = 50%). The CR detected 30% of small PTX, 35% of moderate PTX, and 33% of large PTX. Comparing patients with and without PTX on CR, there were no significant differences in shortness of breath or chest pain. There no relationships between PTX detected

  10. Noninvasive Prenatal Testing and Incidental Detection of Occult Maternal Malignancies.

    Science.gov (United States)

    Bianchi, Diana W; Chudova, Darya; Sehnert, Amy J; Bhatt, Sucheta; Murray, Kathryn; Prosen, Tracy L; Garber, Judy E; Wilkins-Haug, Louise; Vora, Neeta L; Warsof, Stephen; Goldberg, James; Ziainia, Tina; Halks-Miller, Meredith

    2015-07-14

    Understanding the relationship between aneuploidy detection on noninvasive prenatal testing (NIPT) and occult maternal malignancies may explain results that are discordant with the fetal karyotype and improve maternal clinical care. To evaluate massively parallel sequencing data for patterns of copy-number variations that might prospectively identify occult maternal malignancies. Case series identified from 125,426 samples submitted between February 15, 2012, and September 30, 2014, from asymptomatic pregnant women who underwent plasma cell-free DNA sequencing for clinical prenatal aneuploidy screening. Analyses were conducted in a clinical laboratory that performs DNA sequencing. Among the clinical samples, abnormal results were detected in 3757 (3%); these were reported to the ordering physician with recommendations for further evaluation. NIPT for fetal aneuploidy screening (chromosomes 13, 18, 21, X, and Y). Detailed genome-wide bioinformatics analysis was performed on available sequencing data from 8 of 10 women with known cancers. Genome-wide copy-number changes in the original NIPT samples and in subsequent serial samples from individual patients when available are reported. Copy-number changes detected in NIPT sequencing data in the known cancer cases were compared with the types of aneuploidies detected in the overall cohort. From a cohort of 125,426 NIPT results, 3757 (3%) were positive for 1 or more aneuploidies involving chromosomes 13, 18, 21, X, or Y. From this set of 3757 samples, 10 cases of maternal cancer were identified. Detailed clinical and sequencing data were obtained in 8. Maternal cancers most frequently occurred with the rare NIPT finding of more than 1 aneuploidy detected (7 known cancers among 39 cases of multiple aneuploidies by NIPT, 18% [95% CI, 7.5%-33.5%]). All 8 cases that underwent further bioinformatics analysis showed unique patterns of nonspecific copy-number gains and losses across multiple chromosomes. In 1 case, blood was

  11. Thermal structure of intense convective clouds derived from GPS radio occultations

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Randel, W. J.; Ho, S. -P.

    2012-01-01

    Thermal structure associated with deep convective clouds is investigated using Global Positioning System (GPS) radio occultation measurements. GPS data are insensitive to the presence of clouds, and provide high vertical resolution and high accuracy measurements to identify associated temperature...... behavior. Deep convective systems are identified using International Satellite Cloud Climatology Project (ISCCP) satellite data, and cloud tops are accurately measured using Cloud-Aerosol Lidar with Orthogonal Polarization (CALIPSO) lidar observations; we focus on 53 cases of near-coincident GPS...

  12. Thermal structure of intense convective clouds derived from GPS radio occultations

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Randel, W. J.; Ho, S.-P.

    2011-01-01

    Thermal structure associated with deep convective clouds is investigated using Global Positioning System (GPS) radio occultation measurements. GPS data are insensitive to the presence of clouds, and provide high vertical resolution and high accuracy measurements to identify associated temperature...... behavior. Deep convective systems are identified using International Satellite Cloud Climatology Project (ISCCP) satellite data, and cloud tops are accurately measured using Cloud-Aerosol Lidar with Orthogonal Polarization (CALIPSO) lidar observations; we focus on 53 cases of near-coincident GPS...

  13. Prevalence of occult inflammatory bowel disease in ankylosing spondylitis.

    Science.gov (United States)

    Costello, P B; Alea, J A; Kennedy, A C; McCluskey, R T; Green, F A

    1980-10-01

    Fifty-five patients with ankylosing spondylitis and 16 control patients matched for sex and age were examined for evidence of occult inflammatory bowel disease. In all patients evaluation included history and physical examination, barium enema, sigmoidoscopy, and rectal biopsy. The results of this study suggest that there is no increased prevalence of occult inflammatory bowel disease in patients with ankylosing spondylitis.

  14. 21 CFR 864.6550 - Occult blood test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occult blood test. 864.6550 Section 864.6550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a...

  15. Molecular and serological detection of occult hepatitis B virus ...

    African Journals Online (AJOL)

    Background: Occult hepatitis B infections are becoming a major global threat, but the available data on its prevalence in various parts of the world are often divergent. Objective: This study aimed to detect occult hepatitis B virus in hepatitis B surface antigen-negative serum using anti-HBc as a marker of previous infection.

  16. Occult Hepatitis B Virus in Gezira State Sudan | Gasmelseed ...

    African Journals Online (AJOL)

    Background: Occult hepatitis B infection (OBI) is simply defined as serologically undetectable hepatitis B surface antigen (HBsAg-ve), despite the presence of circulating HBV DNA. Objective: The aim of this study was to determine the prevalence of occult HBV among Screened HBsAg subjects in Gezira State, Sudan.

  17. Radio Occultation Bending Angle Anomalies During Tropical Cyclones

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Neubert, Torsten; Syndergaard, Stig

    signature in radio occultation profiles in the tropical tropopause layer. Using tropical cyclone best track database and data from the Constellation Observing System for Meteorology, Ionosphere and Climate (COSMIC), we show that the bending angle anomaly of a GPS radio occultation signal is typically larger...

  18. Neurogenic bladder from occult herpes zoster.

    Science.gov (United States)

    Rothrock, J F; Walicke, P A; Swenson, M R

    1986-11-01

    Active infection with herpes zoster may cause acute urinary retention, especially when it involves sacral dermatomes. Although frank retention usually develops days to weeks after eruption of the typical rash, bladder incompetence infrequently develops first, raising concern over other, more ominous etiologies. In the case presented, rash appearance was delayed until six weeks after the initial onset of urinary retention, a much longer interval than previously reported. Occult herpes zoster infection should be considered in patients presenting with an acute neurogenic bladder of obscure cause.

  19. Small Spacecraft Constellation Concept for Mars Atmospheric Radio Occultations

    Science.gov (United States)

    Asmar, S. W.; Mannucci, A. J.; Ao, C. O.; Kobayashi, M. M.; Lazio, J.; Marinan, A.; Massone, G.; McCandless, S. E.; Preston, R. A.; Seubert, J.; Williamson, W.

    2017-12-01

    First demonstrated in 1965 when Mariner IV flew by Mars and determined the salient features of its atmosphere, radio occultation experiments have been carried out on numerous planetary missions with great discoveries. These experiments utilize the now classic configuration of a signal from a single planetary spacecraft to Earth receiving stations, where the science data are acquired. The Earth science community advanced the technique to utilizing a constellation of spacecraft with the radio occultation links between the spacecraft, enabled by the infrastructure of the Global Positioning System. With the advent of small and less costly spacecraft, such as planetary CubeSats and other variations, such as the anticipated innovative Mars Cube One mission, crosslinks among small spacecraft can be used to study other planets in the near future. Advantages of this type of experiment include significantly greater geographical coverage, which could reach global coverage over a few weeks with a small number of spacecraft. Repeatability of the global coverage can lead to examining temperature-pressure profiles and ionospheric electron density profiles, on daily, seasonal, annual, or other time scales of interest. The higher signal-to-noise ratio for inter-satellite links, compared to a link to Earth, decreases the design demands on the instrumentation (smaller antennas and transmitters, etc.). After an actual Mars crosslink demonstration, this concept has been in development using Mars as a possible target. Scientific objectives, delivery methods, operational scenarios and end-to-end configuration have been documented. Science objectives include determining the state and variability of the lower Martian atmosphere, which has been an identified as a high priority objective by the Mars Exploration Program Analysis Group, particularly as it relates to entry, descent, and landing and ascent for future crewed and robotic missions. This paper will present the latest research on the

  20. Astrometry of the Orcus/Vanth occultation on UT 7 March 2017

    Science.gov (United States)

    Bosh, Amanda S.; Zuluaga, Carlos; Levine, Stephen; Sickafoose, Amanda A.; Genade, Anja; Schindler, Karsten; Lister, Tim; Person, Michael J.

    2017-10-01

    On UT 7 March 2017, Orcus was predicted to occult a star with m=14.3. Observations were made at five observatories: the 0.6-m Astronomical Telescope of the University of Stuttgart (ATUS) at Sierra Remote Observatories (SRO), California; Las Cumbres Observatory’s 1-m telescope (ELP) at McDonald Observatory, Fort Davis, Texas; NASA’s 3-m InfraRed Telescope Facility (IRTF) on Mauna Kea, Hawaii; the 4.1-m Southern Astrophysical Research telescope (SOAR) on Cerro Pachón, Chile; and the 0.6-m Southeastern Association for Research in Astronomy telescope (SARA-CT) at Cerro Tololo, Chile. While observations at all sites were successful, only two—ELP and IRTF—observed solid-body occultation signatures. We will discuss the various predictions for this event and the reasons for the differences among them, including an offset of 130 mas for the star position from the position in the Gaia catalog. The sum of the positive and negative detections place constraints on the geometry of the Orcus/Vanth system, and we present our astrometric results for the geometric solution for this occultation. The implications of the light curve analyses are presented by Sickafoose et al., this conference.

  1. The Human Urine Metabolome

    Science.gov (United States)

    Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.

    2013-01-01

    Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing

  2. 24-hour urine protein

    Science.gov (United States)

    ... your provider may be able to order a test that is done on just one urine sample (protein-to-creatinine ratio). Normal Results The normal ... Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test ... Abnormal results may be due to: A group ...

  3. Citric acid urine test

    Science.gov (United States)

    Urine - citric acid test; Renal tubular acidosis - citric acid test; Kidney stones - citric acid test; Urolithiasis - citric acid test ... No special preparation is necessary for this test. But the results ... test is usually done while you are on a normal diet. Ask your ...

  4. Sniffer mice discriminate urine odours of patients with bladder cancer: A proof-of-principle study for non-invasive diagnosis of cancer-induced odours.

    Science.gov (United States)

    Sato, Takaaki; Katsuoka, Yoji; Yoneda, Kimihiko; Nonomura, Mitsuo; Uchimoto, Shinya; Kobayakawa, Reiko; Kobayakawa, Ko; Mizutani, Yoichi

    2017-11-07

    Similar to fingerprints, humans have unique, genetically determined body odours. In case of urine, the odour can change due to variations in diet as well as upon infection or tumour formation. We investigated the use of mice in a manner similar to "sniffer dogs" to detect changes in urine odour in patients with bladder cancer. We measured the odour discrimination thresholds of mice in a Y-maze, using urine mixtures from patients with bladder cancer (Stage I) and healthy volunteers (dietary variations) as well as occult blood- or antibiotic drug metabolite-modulated samples. Threshold difference indicated that intensities of urinary olfactory cues increase in the following order: dietary variation < bladder cancer < occult blood < antibiotic drug metabolites. After training with patient urine mixtures, sniffer mice discriminated between urine odours of pre- and post-transurethral resection in individual patients with bladder cancer in an equal-occult blood diluted condition below the detection level of dietary variations, achieving a success rate of 100% (11/11). Furthermore, genetic ablation of all dorsal olfactory receptors elevated the discrimination thresholds of mice by ≥ 10 5 -fold. The marked reduction in discrimination sensitivity indicates an essential role of the dorsal olfactory receptors in the recognition of urinary body odours in mice.

  5. Automated color classification of urine dipstick image in urine examination

    Science.gov (United States)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  6. CT detection of occult pneumothorax in head trauma

    International Nuclear Information System (INIS)

    Tocino, I.M.; Miller, M.H.; Frederick, P.R.; Bahr, A.L.; Thomas, F.

    1984-01-01

    A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothorax during subsequent mechanical ventilation or emergency surgery under general anesthesia

  7. CT detection of occult pneumothorax in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Tocino, I.M.; Miller, M.H.; Frederick, P.R.; Bahr, A.L.; Thomas, F.

    1984-11-01

    A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothorax during subsequent mechanical ventilation or emergency surgery under general anesthesia.

  8. Urine pH test

    Science.gov (United States)

    ... urine test Male urinary tract References Bose A, Monk RD, Bushinsky DA. Kidney stones. In: Melmed S, Polonsky ... and its influence on urine pH. J Am Diet Assoc . 1995;95(7):791-797. PMID: 7797810 ...

  9. Profiling Saturn's rings by radio occultation

    International Nuclear Information System (INIS)

    Marouf, E.A.; Tyler, G.L.; Rosen, P.A.

    1986-01-01

    The development of reconstruction algorithms that correct for diffraction effects in radio occultation measurements is described. The reciprocal Fresnel transform relationship between the complex amplitude of the observed coherent signal and the complex microwave transmittance of the rings is derived using the Huygens-Fresnel formulation of the diffraction problem. The effects of the finite data segment width, the uncertainties in the Fresnel scale, systematic phase errors in the kernel of the inverse transform, reference oscillator instabilities, and random noise measurements on the resolution of the reconstructed transmittance are analyzed. Examples of reconstructed opacity profiles for some regions of Saturn's rings derived by applying the reconstruction theory to Voyager 1 at Saturn data are presented. 35 references

  10. Occult hepatitis B infection in children with chronic liver disease.

    Science.gov (United States)

    Srivastava, Anshu; Mathias, Amrita; Yachha, Surender K; Aggarwal, Rakesh

    2015-04-01

    Occult hepatitis B infection (OBI) may adversely affect the outcome of patients with chronic liver disease (CLD). There are no data on OBI and CLD in children. This study determined the prevalence and effect of OBI in HBsAg-negative CLD children. CLD children were prospectively evaluated with a demographic, clinical, and investigative proforma. All HBsAg-negative CLD cases were tested for exposure to hepatitis B (total anti-HBc, anti-HBs). Serum hepatitis B virus DNA was measured in exposed (total anti-HBc positive) patients. A total of 115 HBsAg-negative CLD children (59 boys, age 9.0±3.6 years) were enrolled. The etiology of CLD was known in 94 cases and 21 children had cryptogenic CLD. Of these, 45 (39.1%) had evidence of HBV exposure (23 total anti-HBc positive, 17 total anti-HBc and anti-HBs positive, five only anti-HBs positive without previous vaccination). The anti-HBc-positive children had a higher Child's score than the anti-HBc-negative children [11 (5-13) vs. 7 (5-13); P=0.00]. A total of 4/45 children had seropositive OBI with serum HBV DNA of 8, 36, 133, and 156 IU/ml, respectively. The proportion of total anti-HBc positivity (8/21 vs. 32/94; P=0.8) and OBI (2/21 vs. 2/94; P=0.1) was similar in cryptogenic CLD and known cause CLD. Seropositive OBI is infrequent in Indian children with CLD. The prevalence is similar in cryptogenic and CLD of known etiology.

  11. The prevalence of visible and/or occult blood on anesthesia and monitoring equipment.

    Science.gov (United States)

    Perry, S M; Monaghan, W P

    2001-02-01

    The Occupational Safety and Health Administration (OSHA) and the Centers for Disease Control and Prevention (CDC) have attempted to stop the spread of blood-borne pathogens by issuing several recommendations and regulations. However, unless healthcare workers comply with these standards, they are not effective. In the anesthesia care environment, the anesthetist is responsible for ensuring that the equipment is clean, and disinfected, before use. We studied the prevalence of visible and occult blood on 6 types of anesthesia and monitoring equipment identified as ready for use in 28 operating suites, in 2 facilities. The sample consisted of 336 observations of the 6 types of equipment. The equipment was inspected for visible blood and then tested for occult blood using a 3-stage phenolphthalein test. Of the 336 observations, 110 (32.7%), were positive for occult blood with only 6 showing visible blood. The presence of blood on this equipment may be in direct violation of the OSHA Blood-borne Pathogen Standard and the infection control guidelines of the American Association of Nurse Anesthetists. Furthermore, the presence of blood on this equipment may increase the risk for nosocomial and occupational exposure to viral and bacterial pathogens. Recommendations were made to decrease the risks from this contamination by redesigning equipment, increasing the use of disposable equipment, and ensuring compliance with effective infection control practices.

  12. Verify Occulter Deployment Tolerances as Part of NASA's Technology Development for Exoplanet Missions

    Science.gov (United States)

    Kasdin, N. J.; Shaklan, S.; Lisman, D.; Thomson, M.; Webb, D.; Cady, E.; Marks, G. W.; Lo, A.

    2013-01-01

    In support of NASA's Exoplanet Exploration Program and the Technology Development for Exoplanet Missions (TDEM), we recently completed a 2 year study of the manufacturability and metrology of starshade petals. An external occult is a satellite employing a large screen, or starshade, that flies in formation with a spaceborne telescope to provide the starlight suppression needed for detecting and characterizing exoplanets. Among the advantages of using an occulter are the broadband allowed for characterization and the removal of light before entering the observatory, greatly relaxing the requirements on the telescope and instrument. This poster presents the results of our successful first TDEM that demonstrated an occulter petal could be built and measured to an accuracy consistent with close to 10^-10 contrast. We also present the progress in our second TDEM to demonstrate the next critical technology milestone: precision deployment of the central truss and petals to the necessary accuracy. We have completed manufacture of four sub-scale petals and a central hub to fit with an existing deployable truss. We show the plans for repeated stow and deploy tests of the assembly and the metrology to confirm that each deploy repeatably meets the absolute positioning requirements of the petals (better than 1.0 mm).

  13. Significance of occult hbv infection in patients with chronic hepatitis c

    International Nuclear Information System (INIS)

    Anwar, W.; Sarwar, M.; Saif, M.; Hussain, A.B.; Tariq, W.Z.

    2006-01-01

    Objective: To determine the frequency of occurrence of occult Hepatitis B infection in chronic hepatitis C patients and its impact (if any) on the effectivity of standard chronic hepatitis C treatment. Design: Quasi-experimental study. Place and Duration of Study: The study was conducted at the Department of Medicine, Military Hospital, Rawalpindi, and Virology Department, Armed Forces Institute of Pathology, Rawalpindi, for a period of nine months from January 2003 to September 2003. Patients and Methods: This study was conducted on 30 HBsAg negative patients with chronic hepatitis C liver disease who were receiving combination therapy with interferon and ribavirin. Occult hepatitis B infection was assessed by carrying out HBV DNA by polymerase chain reaction (PCR) in the sera of these patients. Markers of previous hepatitis B infection Le; anti-HBs and total anti-HBc antibodies were also tested. Response to treatment for hepatitis C (with interferon and ribavirin) was assessed at the end of six months of therapy by measuring ALT levels and HCV RNA by PCR in the serum. Results: In our study only one patient (3.33%) was found to be harbouring HBV DNA in the serum detectable by PCR, with markers of previous HBV infection (both anti HBc antibodies and anti HBs antibodies were positive). A total 14 patients (46.67%) had markers of previous HBV infection, while 16 patients (53.33%) had no such sero markers. Twenty five out of 30 patients (83.33%) responded to treatment and 5 (16.66%) turned out to be non-responders. The single case of occult hepatitis B detected in this study responded to hepatitis C treatment. Conclusion: Occult hepatitis B is not a common occurrence in chronic hepatitis C patients and it did not alter the outcome of treatment for hepatitis C in our study. (author)

  14. Atmospheric stability index using radio occultation refractivity profiles

    Indian Academy of Sciences (India)

    A new stability index based on atmospheric refractivity at ∼500 hPa level and surface measurements of temperature ... able at different heights rather than pressure levels. However ..... the radio occultation technique being a limb sound-.

  15. Characterization and evolution of distant planetary atmospheres using stellar occultations

    Science.gov (United States)

    Young, L. A.

    2008-09-01

    Ground-based or near-Earth (e.g., HST) stellar occultations of every atmosphere in our solar system has been observed: Venus, Mars, Jupiter, Saturn, Titan, Uranus, Neptune, Triton, and Pluto [1]. These observations probe the atmospheres at roughly 0.1 to 100 microbar. I will talk about three aspects of stellar occultations: one-dimensional vertical profiles of the atmosphere, two- or three-dimensional atmospheric states, and the time evolution of atmosphere. In all three, I will draw on recent observations, with an emphasis on Pluto. Occultations are particularly important for the study of Pluto's atmosphere, which is impossible to study with imaging, and extremely difficult to study with spectroscopy. It was discovered by stellar occultation in 1988 [2]. No subsequent Pluto occultations were observed until two events in 2002 [3]. Pluto is now crossing the galactic plane, and there have been several additional occultations observed since 2006. These include a high signal-to-noise observation from the Anglo Australian Observatory in 2006 [4] (Fig 1), densely spaced visible and infrared observations of Pluto's upper atmosphere from telescopes in the US and Mexico in March, 2007 [5] (Fig. 2), and a dualwavelength central flash observation from Mt. John in July, 2007 [6] (Fig 3). The flux from a star occulted by an atmosphere diminishes primarily due to the increase in refraction with depth in the atmosphere, defocusing the starlight, although absorption and tangential focusing can also contribute. Because the atmospheric density, to first order, follows an exponential, it is feasible to derive a characteristic pressure and temperature from isothermal fits to even low-quality occultation light curves. Higher quality light curves allow fits with more flexible models, or light curve inversions that derive temperatures limited by the resolution of the data. These allow the derivation of one-dimensional profiles of temperature and pressure vs. altitude, which are critical

  16. UARS Halogen Occultation Experiment (HALOE) Level 2 V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The HALOE home page on the WWW is http://haloe.gats-inc.com/home/index.php The Halogen Occultation Experiment (HALOE) on NASA's Upper Atmosphere Research Satellite...

  17. Photoreceptor atrophy in acute zonal occult outer retinopathy

    DEFF Research Database (Denmark)

    Zibrandtsen, N.; Munch, I.C.; Klemp, K.

    2006-01-01

    Purpose: To assess retinal morphology in acute zonal occult outer retinopathy (AZOOR). Methods: Three patients with a normal ophthalmoscopic fundus appearance, a history of photopsia, and visual field loss compatible with AZOOR were examined using optical coherence tomography, automated perimetry...

  18. [MRI findings and pathological features of occult breast cancer].

    Science.gov (United States)

    Zhang, J J; Yang, X T; Du, X S; Zhang, J X; Hou, L N; Niu, J L

    2018-01-23

    Objective: To investigate the magnetic resonance imaging (MRI) findings and clinicopathological features of primary lesions in patients with occult breast cancer (OBC). Methods: The imaging reports from the Breast Imaging Reporting and Data System in 2013 were retrospectively analyzed to investigate the morphology and the time signal intensity curve (TIC) of breast lesions in patients with OBC. The clinical and pathological characteristics of these patients were also included. Results: A total of 34 patients were enrolled. Among these patients, 24 patients underwent modified radical mastectomy and 18 of them had primary breast carcinoma in pathological sections. MRI detected 17 cases of primary lesions, including six masse lesions with a diameter of 0.6-1.2 cm (average 0.9 cm), and 11 non-mass lesions with four linear distributions, three segmental distributions, three focal distributions, and one regions distribution. Five patients had TIC typeⅠprimary lesions, ten had TIC type Ⅱ primary lesions, and two had TIC type Ⅲ primary lesions. Among all 34 cases, 23 of them had complete results of immunohistochemistry: 11 estrogen receptor (ER) positive lesions (47.8%), tenprogesterone receptor (PR) positive lesions (43.5%), seven human epidermal growth factor receptor 2 (HER-2) positive lesions (30.4%), and 20high expression(>14%) of Ki-67 (87.0%). The proportion of type luminal A was 4.3%, type luminal B was 43.5%, triple negative breast cancer (TNBC) was 30.4%, and HER-2 over expression accounted for 21.7%. Conclusions: The primary lesions of OBC usually manifested as small mass lesions, or focal, linear or segmental distribution of non-mass lesions. The positive rate of ER and PR was low, but the positive rate of HER-2 and the proliferation index of Ki-67 was high. Type luminal B is the most common molecular subtype.

  19. Electrolytic pretreatment of urine

    Science.gov (United States)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  20. Diagnostic strategy for occult hepatitis B virus infection

    Science.gov (United States)

    Ocana, Sara; Casas, Maria Luisa; Buhigas, Ingrid; Lledo, Jose Luis

    2011-01-01

    In 2008, the European Association for the study of the liver (EASL) defined occult hepatitis B virus infection (OBI) as the “presence of hepatitis B virus (HBV) DNA in the liver (with detectable or undetectable HBV DNA in the serum) of individuals testing hepatitis B surface antigen (HBsAg) negative by currently available assays”. Several aspects of occult HBV infection are still poorly understood, including the definition itself and a standardized approach for laboratory-based detection, which is the purpose of this review. The clinical significance of OBI has not yet been established; however, in terms of public health, the clinical importance arises from the risk of HBV transmission. Consequently, it is important to detect high-risk groups for occult HBV infection to prevent transmission. The main issue is, perhaps, to identify the target population for screening OBI. Viremia is very low or undetectable in occult HBV infection, even when the most sensitive methods are used, and the detection of the viral DNA reservoir in hepatocytes would provide the best evaluation of occult HBV prevalence in a defined set of patients. However, this diagnostic approach is obviously unsuitable: blood detection of occult hepatitis B requires assays of the highest sensitivity and specificity with a lower limit of detection < 10 IU/mL for HBV DNA and < 0.1 ng/mL for HBsAg. PMID:21472120

  1. Possible occultation by Pluto from US East Coast

    Science.gov (United States)

    Waagen, Elizabeth O.

    2012-06-01

    We have been asked to help disseminate the news of a possible occultation by Pluto visible to observers on the US East coast. Although the AAVSO does not ordinarily issue announcements of upcoming occultations, in this case the object is Pluto and the NASA New Horizons mission (http://www.nasa.gov/mission_pages/newhorizons/main/index.html) will be visiting Pluto in 2015. The information below has been supplied by Dr. Leslie Young (Southwest Research Institute), who is coordinating this observing campaign on Pluto. Dr. Young is also Deputy Project Scientist for the New Horizons mission. ALERT: Possible Pluto occultation Wednesday night (2012/06/14 03:28 UT) from US East coast. CONTACT: Leslie Young (layoung@boulder.swri.edu; work: 303-546-6057; skype: drpluto). Also see our planning pages in progress at http://wiki.boulder.swri.edu/mediawiki/index.php/2012-06-14_Pluto_occultation. Pluto's thin, nitrogen atmosphere is in vapor-pressure equilibrium with the surface ice, and changes seasonally. We've seen it double since 1988, and now we measure its pressure once or twice a year. The technique we use is stellar occultation, when a star passes behind Pluto's atmosphere. The atmosphere defocuses the starlight. By the timing of the fading of the star, we measure the pressure and temperature in Pluto's atmosphere at ~10 km resolution. MORE INFORMATION: See http://wiki.boulder.swri.edu/mediawiki/index.php/2012-06-14_Pluto_occultation.

  2. Exploring atmospheric blocking with GPS radio occultation observations

    Directory of Open Access Journals (Sweden)

    L. Brunner

    2016-04-01

    Full Text Available Atmospheric blocking has been closely investigated in recent years due to its impact on weather and climate, such as heat waves, droughts, and flooding. We use, for the first time, satellite-based observations from Global Positioning System (GPS radio occultation (RO and explore their ability to resolve blocking in order to potentially open up new avenues complementing models and reanalyses. RO delivers globally available and vertically highly resolved profiles of atmospheric variables such as temperature and geopotential height (GPH. Applying a standard blocking detection algorithm, we find that RO data robustly capture blocking as demonstrated for two well-known blocking events over Russia in summer 2010 and over Greenland in late winter 2013. During blocking episodes, vertically resolved GPH gradients show a distinct anomalous behavior compared to climatological conditions up to 300 hPa and sometimes even further up into the tropopause. The accompanying increase in GPH of up to 300 m in the upper troposphere yields a pronounced tropopause height increase. Corresponding temperatures rise up to 10 K in the middle and lower troposphere. These results demonstrate the feasibility and potential of RO to detect and resolve blocking and in particular to explore the vertical structure of the atmosphere during blocking episodes. This new observation-based view is available globally at the same quality so that blocking in the Southern Hemisphere can also be studied with the same reliability as in the Northern Hemisphere.

  3. Assimilation of GNSS radio occultation observations in GRAPES

    Science.gov (United States)

    Liu, Y.; Xue, J.

    2014-07-01

    This paper reviews the development of the global navigation satellite system (GNSS) radio occultation (RO) observations assimilation in the Global/Regional Assimilation and PrEdiction System (GRAPES) of China Meteorological Administration, including the choice of data to assimilate, the data quality control, the observation operator, the tuning of observation error, and the results of the observation impact experiments. The results indicate that RO data have a significantly positive effect on analysis and forecast at all ranges in GRAPES not only in the Southern Hemisphere where conventional observations are lacking but also in the Northern Hemisphere where data are rich. It is noted that a relatively simple assimilation and forecast system in which only the conventional and RO observation are assimilated still has analysis and forecast skill even after nine months integration, and the analysis difference between both hemispheres is gradually reduced with height when compared with NCEP (National Centers for Enviromental Prediction) analysis. Finally, as a result of the new onboard payload of the Chinese FengYun-3 (FY-3) satellites, the research status of the RO of FY-3 satellites is also presented.

  4. Occult pneumomediastinum in blunt chest trauma: clinical significance.

    Science.gov (United States)

    Rezende-Neto, J B; Hoffmann, J; Al Mahroos, M; Tien, H; Hsee, L C; Spencer Netto, F; Speers, V; Rizoli, S B

    2010-01-01

    Thoracic injuries are potentially responsible for 25% of all trauma deaths. Chest X-ray is commonly used to screen patients with chest injury. However, the use of computed tomography (CT) scan for primary screening is increasing, particularly for blunt trauma. CT scans are more sensitive than chest X-ray in detecting intra-thoracic abnormalities such as pneumothoraces and pneumomediastinums. Pneumomediastinum detected by chest X-ray or "overt pneumomediastinum", raises the concern of possible aerodigestive tract injuries. In contrast, there is scarce information on the clinical significance of pneumomediastinum diagnosed by CT scan only or "occult pneumomediastinum". Therefore we investigated the clinical consequences of occult pneumomediastinum in our blunt trauma population. A 2-year retrospective chart review of all blunt chest trauma patients with initial chest CT scan admitted to a level I trauma centre. Data extracted from the medical records include; demographics, occult, overt, or no pneumomediastinum, the presence of intra-thoracic aerodigestive tract injuries (trachea, bronchus, and/or esophagus), mechanism and severity of injury, endotracheal intubation, chest thoracostomy, operations and radiological reports by an attending radiologist. All patients with intra-thoracic aerodigestive tract injuries from 1994 to 2004 were also investigated. Of 897 patients who met the inclusion criteria 839 (93.5%) had no pneumomediastinum. Five patients (0.6%) had overt pneumomediastinum and 53 patients (5.9%) had occult pneumomediastinum. Patients with occult pneumomediastinum had significantly higher ISS and AIS chest (pchest thoracostomy tube was more common (ppneumothorax. None of the patients with occult pneumomediastinum had aerodigestive tract injuries (95%CI 0-0.06). Follow up CT scan of patients with occult pneumomediastinum showed complete resolution in all cases, in average 3 h after the initial exam. Occult pneumomediastinum occurred in approximately 6% of

  5. Greater trochanteric fracture with occult intertrochanteric extension.

    Science.gov (United States)

    Reiter, Michael; O'Brien, Seth D; Bui-Mansfield, Liem T; Alderete, Joseph

    2013-10-01

    Proximal femoral fractures are frequently encountered in the emergency department (ED). Prompt diagnosis is paramount as delay will exacerbate the already poor outcomes associated with these injuries. In cases where radiography is negative but clinical suspicion remains high, magnetic resonance imaging (MRI) is the study of choice as it has the capability to depict fractures which are occult on other imaging modalities. Awareness of a particular subset of proximal femoral fractures, namely greater trochanteric fractures, is vital for both radiologists and clinicians since it has been well documented that they invariably have an intertrochanteric component which may require surgical management. The detection of intertrochanteric or cervical extension of greater trochanteric fractures has been described utilizing MRI but is underestimated with both computed tomography (CT) and bone scan. Therefore, if MRI is unavailable or contraindicated, the diagnosis of an isolated greater trochanteric fracture should be met with caution. The importance of avoiding this potential pitfall is demonstrated in the following case of an elderly woman with hip pain and CT demonstrating an isolated greater trochanteric fracture who subsequently returned to the ED with a displaced intertrochanteric fracture.

  6. Visible and occult microscopic lesions of endometriosis

    Directory of Open Access Journals (Sweden)

    Khaleque Newaz Khan

    2014-11-01

    Full Text Available Endometriosis is a multifactorial disease mostly affecting women of reproductive age and is associated with chronic pelvic pain and infertility. Even after 300 years, most of the literature claims that pathogenesis and/or pathophysiology of endometriosis is still elusive. Recurrence of pain and lesion continues to occur after effective medical or surgical therapies. Once generated within the pelvis due to retrograde entry of menstrual debris, peritoneal endometriotic lesions time-dependently change their color appearance resulting from certain biochemical change within lesions. A variable pattern of endometriotic lesions within the pelvis can be detected by laparoscopy as visible peritoneal endometriosis. It is generally believed that besides ovarian steroid hormones, the growth of endometriosis can be regulated by the innate immune system in the pelvic microenvironment by their interaction with endometrial cells and immune cells. Even with the careful eyes of an expert surgeon, we may sometimes miss detecting peritoneal lesion within the peritoneal cavity or deep into the peritoneum. In such a case, random collection of normal peritoneum may carry the possibility to identify some hidden endometriotic lesions by microscopy and these lesions can be named as occult (invisible microscopic endometriosis (OME. Here, we discuss the color appearance of peritoneal lesions and activity of these lesions by analysis of a panel of activity markers. Finally we discuss our recent findings on OME, their biological and clinical significance, and try to make a possible link in the origin between visible endometriosis and OME.

  7. Celestial shadows eclipses, transits, and occultations

    CERN Document Server

    Westfall, John

    2015-01-01

    Much of what is known about the universe comes from the study of celestial shadows—eclipses, transits, and occultations.  The most dramatic are total eclipses of the Sun, which constitute one of the most dramatic and awe-inspiring events of nature.  Though once a source of consternation or dread, solar eclipses now lead thousands of amateur astronomers and eclipse-chasers to travel to remote points on the globe to savor their beauty and the adrenaline-rush of experiencing totality, and were long the only source of information about the hauntingly beautiful chromosphere and corona of the Sun.   Long before Columbus, the curved shadow of the Earth on the Moon during a lunar eclipse revealed that we inhabit a round world. The rare and wonderful transits of Venus, which occur as it passes between the Earth and the Sun, inspired eighteenth century expeditions to measure the distance from the Earth to the Sun, while the recent transits of 2004 and 2012 were the most widely observed ever--and still produced re...

  8. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    Science.gov (United States)

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Prevalence, risk factors, and impact of isolated antibody to hepatitis B core antigen and occult hepatitis B virus infection in HIV-1-infected pregnant women.

    Science.gov (United States)

    Khamduang, Woottichai; Ngo-Giang-Huong, Nicole; Gaudy-Graffin, Catherine; Jourdain, Gonzague; Suwankornsakul, Weerapong; Jarupanich, Tapnarong; Chalermpolprapa, Veeradate; Nanta, Sirisak; Puarattana-Aroonkorn, Noossara; Tonmat, Sakchai; Lallemant, Marc; Goudeau, Alain; Sirirungsi, Wasna

    2013-06-01

    Prevalence and risk factors for isolated antibody to hepatitis B core antigen (anti-HBc) and occult hepatitis B virus (HBV) infection are not well known in human immunodeficiency virus type 1 (HIV-1)-infected pregnant women. It is unclear if women with occult infections are at risk of transmitting HBV to their infants. HIV-1-infected and HBV surface antigen (HBsAg)-negative pregnant women were tested for antibody to HBsAg (anti-HBs) and anti-HBc using enzyme immunoassay. Women with isolated anti-HBc were assessed for occult HBV infection, defined as HBV DNA levels >15 IU/mL, using the Abbott RealTime HBV DNA assay. Infants born to women with isolated anti-HBc and detectable HBV DNA were tested at 4 months of age for HBV DNA. Logistic regression analysis was used to identify factors associated with isolated anti-HBc and occult HBV infection. Among 1812 HIV-infected pregnant women, 1682 were HBsAg negative. Fourteen percent (95% confidence interval [CI], 12%-15%) of HBsAg-negative women had an isolated anti-HBc that was independently associated with low CD4 count, age >35 years, birth in northern Thailand, and positive anti-hepatitis C virus serology. Occult HBV infection was identified in 24% (95% CI, 18%-30%) of women with isolated anti-HBc, representing 2.6% (95% CI, 1.9%-3.5%) of HIV-1-infected pregnant women, and was inversely associated with HIV RNA levels. None of the women with isolated anti-HBc and occult HBV infection transmitted HBV to their infants. HIV-1-infected pregnant women with isolated anti-HBc and occult HBV infection have very low HBV DNA levels and are thus at very low risk to transmit HBV to their infants.

  10. Goethe’s theory of colors between the ancient philosophy, middle ages occultism and modern science

    Directory of Open Access Journals (Sweden)

    Victor Barsan

    2016-12-01

    Full Text Available Goethe’s rejection of Newton’s theory of colors is an interesting example of the vulnerability of the human mind—however brilliant it might be—to fanaticism. After an analysis of Goethe’s persistent fascination with magic and occultism, of his education, existential experiences, influences, and idiosyncrasies, the authors propose an original interpretation of his anti-Newtonian position. The relevance of Goethe’s Farbenlehre to physics and physiology, from the perspective of modern science, is discussed in detail.

  11. Electron number density profiles derived from radio occultation on the CASSIOPE spacecraft

    DEFF Research Database (Denmark)

    Shume, E. B.; Vergados, P.; Komjathy, A.

    2017-01-01

    This paper presents electron number density profiles derived from high resolution Global Positioning System (GPS) radio occultation (RO) observations performed using the Enhanced Polar Outflow Probe (e-POP) payload on the high inclination CAScade, Smallsat and IOnospheric Polar Explorer (CASSIOPE...... good agreement with density profiles estimated from ionosonde data, measured over nearby stations to the latitude and longitude of the RO tangent points, (2) in good agreement with density profiles inferred from GPS RO measured by the Constellation Observing System for Meteorology, Ionosphere...

  12. Unusual Case of Occult Brucella Osteomyelitis in the Skull Detected by Bone Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Lim, Seok Tae; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Lee, Chang Seob [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2010-06-15

    Brucellosis is a worldwide infectious disease of animals that can be transmitted to humans. Osteoarticular involvement is the most common complication of brucellosis. A 47-year-old man, who was a stock breeder, complained of myalgia with fever and chills for 2 weeks. The serology titers and blood cultures for brucellosis were positive. Bone scintigraphy demonstrated a focally increased uptake in the left supra orbital area. Plain radiographs showed an osteolytic lesion, and an MRI revealed signal abnormalities in the corresponding site. We present an unusual case of occult Brucella osteomyelitis in the frontal bone of the skull detected by done scintigraphy.

  13. Unusual Case of Occult Brucella Osteomyelitis in the Skull Detected by Bone Scintigraphy

    International Nuclear Information System (INIS)

    Sohn, Myung Hee; Lim, Seok Tae; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Lee, Chang Seob

    2010-01-01

    Brucellosis is a worldwide infectious disease of animals that can be transmitted to humans. Osteoarticular involvement is the most common complication of brucellosis. A 47-year-old man, who was a stock breeder, complained of myalgia with fever and chills for 2 weeks. The serology titers and blood cultures for brucellosis were positive. Bone scintigraphy demonstrated a focally increased uptake in the left supra orbital area. Plain radiographs showed an osteolytic lesion, and an MRI revealed signal abnormalities in the corresponding site. We present an unusual case of occult Brucella osteomyelitis in the frontal bone of the skull detected by done scintigraphy.

  14. Recent progress on external occulter technology for imaging exosolar planets

    Science.gov (United States)

    Kasdin, N. J.; Vanderbei, R. J.; Sirbu, D.; Samuels, J.; Shaklan, S.; Lisman, D.; Thomson, M.; Cady, E.; Martin, S.

    Imaging planets orbiting nearby stars requires a system for suppressing the host starlight by at least ten orders of magnitude. One such approach uses an external occulter, a satellite flying far from the telescope and employing a large screen, or starshade, to suppress the incoming starlight. This trades the added complexity of building the precisely shaped starshade and flying it in formation against simplifications in the telescope since extremely precise wavefront control is no longer necessary. Much progress has been made recently in designing, testing and manufacturing starshade technology. In this paper we describe the design of starshades and report on recent accomplishments in manufacturing and measuring a prototype occulter petal as part of NASA's first Technology Development for Exoplanet Missions (TDEM) program. We demonstrate that the as-built petal is consistent with a full-size occulter achieving better than 10-10 contrast. We also discuss laboratory testing at the Princeton Occulter Testbed. These experiments use sub-scale, long-distance beam propagation to verify the diffraction analysis associated with occulter starlight suppression. We demonstrate roughly 10-10 suppression in the laboratory and discuss the important challenges and limitations.

  15. [Occultism, parapsychology and the esoteric from the perspective of psychopathology].

    Science.gov (United States)

    Scharfetter, C

    1998-10-01

    The concepts and main themes of occultism, parapsychology and esoterics are set in comparison to religion, spirituality, mysticism. The cultural relativity of these concepts is emphasised. Occultism means dealing with phenomena, processes, and/or powers which are not accessible to "normal perception". The manipulation of such powers is effected via (white, black, grey) magic. Parapsychology, in its popular sense, deals with occult phenomena, whereas scientific parapsychology investigates them empirically. Esoterics is a complex of beliefs within a hermetic tradition about occult processes and about desting after death. Transpersonal psychology deals with these issues while calling them "spiritual". Effects of paranormal experiences and actions on the side of the actor as well as the adept are discussed: personality types, interpersonal effects, crises and psychoses (mediumistic psychoses). The concept of dissociation of subpersonalities (subselves) appears to be a viable perspective to explain these phenomena. In mediumistic psychoses, the splitting of non-ego parts of the psyche leads to a manifestation of schizophrenic symptoms. Dangers for mental health are an ego inflation by self-attribution of "superhuman" power. A personality disposition for parapsychological perception and/or action may be seen in schizotypia and similar near-psychotic "personalities up the border". Adepts of occultism may present with a "false self" in the sense of Winnicott.

  16. Occult carcinoma discovered after simple hysterectomy treated with postoperative radiotherapy

    International Nuclear Information System (INIS)

    Crane, Christopher H.; Schneider, Bernard F.

    1999-01-01

    Purpose: Treatment of patients with occult carcinoma of the cervix discovered after simple hysterectomy is controversial. The purpose of this review is to examine our results with postoperative radiotherapy and to compare them to similar reports and to reports of treatment with radical parametrectomy. Methods and Materials: Between November 1979 and April:, 18 patients were treated with radiotherapy at the University of Virginia for invasive carcinoma of the cervix discovered after simple hysterectomy. Simple hysterectomy was performed in all 18 patients for a variety of indications. After surgery gross residual carcinoma remained in four patients; and microscopic disease was present at the surgical margins in two patients. The remaining patients had no evidence of residual disease. All 18 patients had postoperative radiotherapy with or without brachytherapy. The endpoints for this study were local control, survival, and treatment-related toxicity. Actuarial rates were calculated using the Life method. Results: Median follow-up for all 18 patients was 42 months (range 2-202 months). Both the 5 and the 10-year actuarial local control rates were 88%. Five and 10-year actuarial overall survival rates were both 93%. Two patients had both local and distant cancer recurrences. There were no recurrences among the six patients treated with external beam alone. The remaining patients are all alive without evidence of disease, including two patients who had gross residual disease after surgery, and one patient with both microscopic positive margin and a positive lymph node (the only patient to undergo lymph node sampling). There was no severe acute morbidity and only one patient had severe late morbidity. Conclusions: Invasive carcinoma found after simple hysterectomy may be treated safely and effectively with postoperative radiotherapy. Patients with known residual disease following surgery do poorly with either radiotherapy or reoperation, but treatment with radiotherapy

  17. Estimate of dietary phosphorus intake using 24-h urine collection

    Science.gov (United States)

    Morimoto, Yuuka; Sakuma, Masae; Ohta, Hiroyuki; Suzuki, Akitsu; Matsushita, Asami; Umeda, Minako; Ishikawa, Makoto; Taketani, Yutaka; Takeda, Eiji; Arai, Hidekazu

    2014-01-01

    Increases in serum phosphorus levels and dietary phosphorus intake induces vascular calcification, arterial sclerosis and cardiovascular diseases. Limiting phosphorus intake is advisable, however, no assessment methods are capable of estimating dietary phosphorus intake. We hypothesized that urinary phosphorus excretion can be translated into estimation of dietary phosphorus intake, and we evaluated whether a 24-h urine collection method could estimate dietary phosphorus intake. Thirty two healthy subjects were recruited for this study. Subjects collected urine samples over 24 h and weighed dietary records. We calculated dietary protein intake and phosphorus intake from dietary records and urine collection, and investigated associations between the two methods in estimating protein and phosphorus intake. Significant positive correlations were observed between dietary records and UC for protein and phosphorus intake. The average intakes determined from dietary records were significantly higher than from urine collection for both protein and phosphorus. There was a significant positive correlation between both the phosphorus and protein difference in dietary records and urine collection. The phosphorus-protein ratio in urine collection was significantly higher than in dietary records. Our data indicated that the 24-h urine collection method can estimate the amount of dietary phosphorus intake, and the results were superior to estimation by weighed dietary record. PMID:25120281

  18. Urine cup for collection of urine from cows.

    Science.gov (United States)

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  19. Comparison of Urine and Oral Fluid for Workplace Drug Testing.

    Science.gov (United States)

    Casolin, Armand

    2016-09-01

    To determine the relative detection rates of urine versus oral fluid testing in a safety sensitive industry and the correlation with diagnosed substance use disorders and possible impairment at work. The trial involved 1,500 paired urine and oral fluid tests performed in accordance with Australian Standard/New Zealand Standard (AS/NZS) 4308:2008 and AS 4760:2006. Workers who returned a positive test were screened for substance use disorders, as defined by DSM-5, and for possible impairment at work following that particular episode of substance use. Substances were detected in 3.7% (n = 56) of urine samples and 0.5% (n = 8) of oral fluid samples (p < 0.0001). One worker (0.07%) had a substance detected on oral fluid alone versus 49 workers (3.3%) who had substances detected on urine alone. Twelve workers returned a positive result, defined as being consistent with the use of an illicit drug or a controlled substance without a clinical indication and prescription. Nine workers tested positive on urine alone, one on oral fluid alone and two on both (p = 0.0114). Of note, 6/11 workers who tested positive on urine had possible impairment at work and 2/11 had a substance use disorder versus 2/3 and 0/3, respectively, who tested positive on oral fluid. Urine drug testing performed in accordance with AS/NZS 4308:2008 is more likely to detect overall substance use and illicit drug use than oral fluid testing conducted in accordance with AS 4760:2006. Urine testing performed in accordance with AS/NZS 4308:2008 may also be more likely to detect workers with possible impairment at work and substance use disorders than oral fluid testing performed in accordance with AS 4760:2006. © The Author 2016. Published by Oxford University Press.

  20. David Levy's Guide to Eclipses, Transits, and Occultations

    Science.gov (United States)

    Levy, David H.

    2010-08-01

    Introduction; Part I. The Magic and History of Eclipses: 1. Shakespeare, King Lear, and the Great Eclipse of 1605; 2. Three centuries later: Einstein, relativity, and the solar eclipse of 1919; 3. What causes solar and lunar eclipses; Part II. Observing Solar Eclipses: 4. Safety considerations; 5. What to expect during a partial eclipse; 6. Annular eclipses and what to see in them; 7. Total eclipse of the Sun: introduction to the magic; 8. The onset: temperature drop, Baily's Beads, Diamond Ring; 9. Totality: Corona, Prominences, Chromosphere, and surrounding area; 10. Photographing and imaging a solar eclipse; Part III. Observing Lunar Eclipses: 11. Don't forget the penumbral eclipses!; 12. Partial lunar eclipses; 13. Total lunar eclipses; 14. Photographing and imaging lunar eclipses; Part IV. Occultations: 15. When the Moon occults a star; Part V. Transits: 16. When planets cross the Sun; Part VI. My Favorite Eclipses: 17. A personal canon of eclipses, occultations, and transits I have seen; Appendices; Index.

  1. Categorizing the Occult: Vodun, Sorcery and Religious Beliefs In Benin

    DEFF Research Database (Denmark)

    Strandsbjerg, Camilla

    2011-01-01

    In everyday life in Benin as well as in academic research on the topic, the terms of vodun, witchcraft and the occult are often used in a non distinct way covering quite similar phenomena while at the same time referring to different kinds of beliefs and practices. The problem of understanding...... confronted with this difficulty. Both because the vodun, as a recognized religion in the country - equal to Islam and Christianity - , plays an important role in society as well as in individual life, but also because all area of social life are on one level or another influenced by beliefs and practices...... characterized as witchcraft or occult. Reflecting upon earlier research and particularly on the choice of terminology of the occult in writing on religion and political change in Benin (PhD thesis 2008), this paper seeks to clarify some of the epistemological, academic and historical reasons that have formed...

  2. Cortisol in urine and saliva

    DEFF Research Database (Denmark)

    Hurwitz Eller, N; Netterstrøm, B; Hansen, Åse Marie

    2001-01-01

    The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis.......The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis....

  3. Exploring small bodies in the outer solar system with stellar occultations

    Science.gov (United States)

    Elliot, Jim L.; Dunham, Edward W.; Olkin, C. B.

    1995-01-01

    Stellar occultation observations probe the atmospheric structure and extinction of outer solar system bodies with a spatial resolution of a few kilometers, and an airborne platform allows the observation of occultations by small bodies that are not visible from fixed telescopes. Results from occultations by Triton, Pluto, and Chiron observed with KAO are discussed, and future directions for this program are presented.

  4. Presentation of Axillary Metastases from Occult Breast Carcinoma

    Institute of Scientific and Technical Information of China (English)

    Xin Wang

    2007-01-01

    Axillary presentation from occult breast cancer is uncommon and continues to be a diagnostic and therapeutic challenge to physicians.Once the diagnosis of adenocarcinoma metastatic to an axillary lymph node has been confirmed,a preoperative workup should be done.The current experience is based on several relatively small retrospective reviews and case reports.It is difficult to determine the best management of occult breast cancer.However,treatmenl of axillary Iymph node dissection is recommended for local control and complete staging information.Treatment of breast should be a choice between breast conservation with whole-breast radiotherapy and mastectomy.Adjuvant systemic treatment should be offered.

  5. Detection of occult abscesses with 111In-labeled leukocytes

    International Nuclear Information System (INIS)

    Martin, W.R.; Gurevich, N.; Goris, M.L.; McDougall, I.R.

    1979-01-01

    Clinicians are frequently faced with the problem of a patient in whom they suspect an occult abscess. In such a situation, there may be no clinical signs to localize the site of the abscess and often extensive investigations do not provide additional useful information. This report illustrates the efficacy of autologous leukocytes labeled with 111 In oxine in detecting the site and extent of occult abscesses in two patients. The technique of in vitro lebeling of leukocytes is simple and has been mastered by all of our nuclear medicine technologists

  6. [Identification of occult disseminated tumor cells by recombinant herpes simplex virus expressing GFP (HSV(GFP))].

    Science.gov (United States)

    Han, Xiang-ping; Shi, Gui-lan; Wang, Cheng-feng; Li, Jie; Zhang, Jian-wei; Zhang, Yu; Zhang, Shu-ren; Liu, Bin-lei

    2012-12-01

    To develop a novel rapid protocol for the detection of occult disseminated tumor cells by a recombinant herpes simplex virus expressing GFP (HSV(GFP)). Tumor cells of seven cell lines were exposed to HSV(GFP) and then examined for GFP expression by fluorescence microscopy. Various numbers of tumor cells (10, 100, 1000, 10 000) were mixed into 2 ml human whole blood, separated with lymphocytes separation medium, exposed to HSV(GFP), incubated at 37°C for 6 - 24 h and then counted for the number of green cells under the fluorescence microscope. Some clinical samples including peripheral blood, pleural effusion, ascites, spinal fluid from tumor-bearing patients were screened using this protocol in parallel with routine cytological examination. HSV(GFP) was able to infect all 7 tumor cell lines indicating that the HSV(GFP) can be used to detect different types of tumor cells. The detection sensitivity was 10 cancer cells in 2 ml whole blood. In the clinical samples, there were 4/15 positive by routine cytological examination but 11/15 positive by HSV(GFP), indicating a higher sensitivity of this new protocol. Recombinant herpes simplex virus-mediated green fluorescence is a simple and sensitive technique for the identification of occult disseminated cancer cells including circulating tumor cells (CTCs).

  7. Prognosis for Mammographically Occult, Early-Stage Breast Cancer Patients Treated With Breast-Conservation Therapy

    International Nuclear Information System (INIS)

    Yang, Tzu-I. J.; Yang Qifeng; Haffty, Bruce G.; Moran, Meena S.

    2010-01-01

    Purpose: To compare mammographically occult (MamOcc) and mammographically positive (MamPos) early-stage breast cancer patients treated with breast-conservation therapy (BCT), to analyze differences between the two cohorts. Methods and Materials: Our two cohorts consisted of 214 MamOcc and 2168 MamPos patients treated with BCT. Chart reviews were conducted to assess mammogram reports and method of detection. All clinical-pathologic and outcome parameters were analyzed to detect differences between the two cohorts. Results: Median follow-up was 7 years. There were no differences in final margins, T stage, nodal status, estrogen/progesterone receptor status, or 'triple-negative' status. Significant differences included younger age at diagnosis (p o histology (p < 0.0001). At 10 years, the differences in overall survival, cause-specific survival, and distant relapse between the two groups did not differ significantly. The MamOcc cohort had more breast relapses (15% vs. 8%; p = 0.0357), but on multivariate analysis this difference was not significant (hazard ratio 1.0, 95% confidence interval 0.993-1.007, p = 0.9296). Breast relapses were mammographically occult in 32% of the MamOcc and 12% of the MamPos cohorts (p = 0.0136). Conclusions: Although our study suggests that there are clinical-pathologic variations for the MamOcc cohort vs. MamPos patients that may ultimately affect management, breast relapse after BCT was not significantly different. Breast recurrences were more often mammographically occult in the MamOcc cohort; consideration should be given to closer follow-up and alternative imaging strategies (ultrasound, breast MRI) for routine posttreatment examination. To our knowledge, this represents the largest series addressing the prognostic significance of MamOcc cancers treated with BCT.

  8. Comparison between the urine dipstick and the pH-meter to assess urine pH in sheep and dogs.

    Science.gov (United States)

    Athanasiou, Labrini V; Katsoulos, Panagiotis D; Katsogiannou, Eleni G; Polizopoulou, Zoe S; Diamantaki, Myrto; Kamatsos, Constantinos; Christodoulopoulos, Georgios

    2018-02-06

    Urine pH is an integral part of a complete urinalysis, and is commonly measured in veterinary practice using semiquantitative reagent strips. The aim of this study was to compare the urine pH of dogs and sheep, using visual interpretation of dipstick reactions, and using a pH-meter as the reference method. Agreement between the 2 methods was also assessed. An additional objective was to compare the urine pH before and after centrifugation. A total of 50 voided urine samples from sheep and 52 from dogs were collected into sterile containers. For pH measurements, 2 methods were used, a pH-meter and urine dipstick reagent pads. Measurements were performed using urine samples before (whole urine) and after centrifugation (urine supernatant). For comparison of the 2 methods, Passing and Bablok regression analysis and Bland-Altman plots were used. The equation created to assess agreement between the 2 methods in dogs showed a constant bias at -0.14 and a positive proportional bias at 0.98. From a clinical standpoint, total bias was below and above the maximum acceptable bias in sheep and dogs, respectively. Clinically acceptable bias was also found using centrifuged urine samples in sheep, but the urine pH values before and after centrifugation were nearly identical in dogs. Urine dipstick reagent pads and pH-meters can be used interchangeably to determine urine pH in sheep without needing centrifugation. In contrast, pH-meters provide more accurate pH measurements than urine dipstick pads in canine urine, which is not improved by centrifugation. © 2018 American Society for Veterinary Clinical Pathology.

  9. Detection of occult HBV infection by nested PCR assay among ...

    African Journals Online (AJOL)

    Occult hepatitis B virus infection (OBI) has been reported among patients with chronic hepatitis C virus (HCV) infection and hepatocellular carcinoma (HCC). This study aimed to evaluate the prevalence of OBI in chronic hepatitis C patients with and without hepatocellular carcinoma. A total of 40 chronic hepatitis C patients ...

  10. Occult spontaneous lateral intrasphenoidal encephalocele: A rare presentation

    Directory of Open Access Journals (Sweden)

    Shahina Bano

    2013-01-01

    Full Text Available Basal encephaloceles are extremely rare congenital malformations. Advanced cross-sectional imaging modalities like computed tomography and magnetic resonance imaging are necessary for diagnosing the asymptomatic, occult basal encephalocele and planning the surgical approach. We present an interesting case of clinically silent right-sided lateral intrasphenoidal encephalocele through a large bony defect.

  11. Pluto-Charon Stellar Occultation Candidates: 1990-1995

    Science.gov (United States)

    Dunham, E. W.; McDonald, S. W.; Elliot, J. L.

    1991-01-01

    We have carried out a search to identify stars that might be occulted by Pluto or Charon during the period 1990-1995 and part of 1996. This search was made with an unfiltered CCD camera operated in the strip scanning mode, and it reaches an R magnitude of approximately 17.5-about 1.5 mag fainter than previous searches. Circumstances for each of the 162 potential occultations are given, including an approximate R magnitude of the star, which allows estimation of the signal-to-noise ratio (S/N) for observation of each occultation. The faintest stars in our list would yield an S/N of about 20 for a 1 S integration when observed with a CCD detector on an 8 m telescope under a dark sky. Our astrometric precision (+/- 0.2 arcsec, with larger systematic errors possible for individual cases) is insufficient to serve as a final prediction for these potential occultations, but is sufficient to identify stars deserving of further, more accurate, astrometric observations. Statistically, we expect about 32 of these events to be observable somewhere on Earth. The number of events actually observed will be substantially smaller because of clouds and the sparse distribution of large telescopes. Finder charts for each of the 91 stars involved are presented.

  12. Radio occultation bending angle anomalies during tropical cyclones

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Neubert, Torsten; Syndergaard, S.

    2011-01-01

    -located radiosondes, climatology of tropopause altitudes and GOES analyses are also shown to support the hypothesis that the bending angle anomaly can be used as an indicator of convective towers. The results are discussed in connection to the GPS radio occultation receiver which will be part of the Atomic Clock...

  13. Past and future of radio occultation studies of planetary atmospheres

    Science.gov (United States)

    Eshleman, Von R.; Hinson, David P.; Tyler, G. Leonard; Lindal, Gunnar F.

    1987-01-01

    Measurements of radio waves that have propagated through planetary atmospheres have provided exploratory results on atmospheric constituents, structure, dynamics, and ionization for Venus, Mars, Titan, Jupiter, Saturn, and Uranus. Highlights of past results are reviewed in order to define and illustrate the potential of occultation and related radio studies in future planetary missions.

  14. A method to detect occult pneumothorax with chest radiography.

    Science.gov (United States)

    Matsumoto, Shokei; Kishikawa, Masanobu; Hayakawa, Koichi; Narumi, Atsushi; Matsunami, Katsutoshi; Kitano, Mitsuhide

    2011-04-01

    Small pneumothoraces are often not visible on supine screening chest radiographs because they develop anteriorly to the lung. These pneumothoraces are termed occult. Occult pneumothoraces account for an astonishingly high 52% to 63% of all traumatic pneumothoraces. A 19-year-old obese woman was involved in a head-on car accident. The admission anteroposterior chest radiographs were unremarkable. Because of the presence of right chest tenderness and an abrasion, we suspected the presence of a pneumothorax. Thus, we decided to take a supine oblique chest radiograph of the right side of the thorax, which clearly revealed a visceral pleural line, consistent with a diagnosis of traumatic pneumothorax. A pneumothorax may be present when a supine chest radiograph reveals either an apparent deepening of the costophrenic angle (the "deep sulcus sign") or the presence of 2 diaphragm-lung interfaces (the "double diaphragm sign"). However, in practice, supine chest radiographs have poor sensitivity for occult pneumothoraces. Oblique chest radiograph is a useful and fast screening tool that should be considered for cases of blunt chest trauma, especially when transport of critically ill patients to the computed tomographic suite is dangerous or when imminent transfer to another hospital is being arranged and early diagnosis of an occult pneumothorax is essential. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  15. Occult Metabolic Bone Disease in Chronic Pancreatitis | Hari Kumar ...

    African Journals Online (AJOL)

    Background: Chronic pancreatitis (CP) leads to malabsorption and metabolic bone disease (MBD). Alcoholic CP (ACP) and tropical CP (TCP) are the two common types of CP. Objective: We investigated the presence of occult MBD in patients with CP and compared the same between ACP and TCP. Materials and Methods: ...

  16. Precise pointing knowledge for SCIAMACHY solar occultation measurements

    Directory of Open Access Journals (Sweden)

    K. Bramstedt

    2012-11-01

    Full Text Available We present a method to precisely determine the viewing direction for solar occultation instruments from scans over the solar disk. Basic idea is the fit of the maximum intensity during the scan, which corresponds to the center of the solar disk in the scanning direction. We apply this method to the solar occultation measurements of the satellite instrument SCIAMACHY, which scans the Sun in elevation direction. The achieved mean precision is 0.46 mdeg, which corresponds to an tangent height error of about 26 m for individual occultation sequences. The deviation of the derived elevation angle from the geolocation information given along with the product has a seasonal cycle with an amplitude of 2.26 mdeg, which is in tangent height an amplitude of about 127 m. The mean elevation angle offset is −4.41 mdeg (249 m. SCIAMACHY's sun follower device controls the azimuth viewing direction during the occultation measurements. The derived mean azimuth direction has an standard error of 0.65 mdeg, which is about 36 m in horizontal direction at the tangent point. We observe also a seasonal cycle of the azimuth mispointing with an amplitude of 2.3 mdeg, which is slightly increasing with time. The almost constant mean offset is 88 mdeg, which is about 5.0 km horizontal offset at the tangent point.

  17. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    Science.gov (United States)

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and

  18. Sensing Water Vapon via Spacecraft Radio Occultation Observations

    Science.gov (United States)

    Kursinski, E. Robert; Hajj, George A.

    2000-01-01

    The radio occultation technique has been used to characterize planetary atmospheres since the 1960's spanning atmospheric pressures from 16 microbars to several bars. In 1988, the use of GPS signals to make occultation observations of Earth's atmosphere was realized by Tom Yunck and Gunnar Lindal at JPL. In the GPS to low-Earth-orbiter limb- viewing occultation geometry, Fresnel diffraction yield a unique combination of high vertical resolution of 100 m to 1 km at long wavelengths (approx. 20 cm) insensitive to particulate scattering which allows routine limb sounding from the lower mesosphere through the troposphere. A single orbiting GPS/GLONASS receiver can observe - 1000 to 1400 daily occultations providing as many daily, high vertical resolution soundings as the present global radiosonde network, but with far more evenly distributed, global coverage. The occultations yield profiles of refractivity as a function of height. In the cold, dry conditions of the upper troposphere and above (T less than 240 K), profiles of density, pressure (geopotential), and temperature can be derived. Given additional temperature information, water vapor can be derived in the midddle and lower troposphere with a unique combination of vertical resolution, global distribution and insensitivity to clouds and precipitation to an accuracy of approx. 0.2 g/kg. At low latitudes, moisture profiles will be accurate to 1-5% within the convective boundary layer and better than 20% below 6 to 7 km. Accuracies of climatological averages should be approx. 0. 1 g/kg limited by the biases in the temperature estimates. To use refractivity to constrain water vapor, knowledge of temperature is required. The simplest approach is to use the temperature field from an analysis such as the 6 hour ECMWF global analysis interpolated to the locations of each occultation. A better approach is to combine the temperature and moisture fields from such an analysis with the occultation refractivity in a weighting

  19. Sonographic swelling of pronator quadratus muscle in patients with occult bone injury

    International Nuclear Information System (INIS)

    Sato, Junko; Ishii, Yoshinori; Noguchi, Hideo; Toyabe, Shin-ichi

    2015-01-01

    The disarranged fat stripe of the pronator quadratus muscle (PQ) on radiographs (the PQ sign) is reported to be predictive of subtle bone fractures. This study aimed to report the results of magnetic resonance imaging (MRI) study in the patients in whom bone injury was not radiographically detected around the wrist joint, and the PQ was sonographically swollen following acute trauma. We evaluated sonographically the PQ of 55 patients who showed normal radiographs following acute trauma. The sonographic appearance of the PQ was checked on both longitudinal and transverse images. On the longitudinal image, the probe was positioned along the flexor carpi radialis tendon. For the transverse image, we adopted the image of the same level in which the PQ of the unaffected hand showed maximal thickness. The PQ was considered to be swollen with disproportionate hyperechogenicity and/or thickening compared with the unaffected side at least in one of the two images. Of the 55 patients, 25 patients whose PQ was considered to be swollen underwent MRI study. PQ thickness in millimeters was retrospectively measured on longitudinal and transverse sonographic images. Twenty-three patients (92.0%) had occult bone injury, and two adult patients (8.0%) showed only wrist joint effusion on MRI. Among these 23, the distal radius was the most frequent location of the occult bone injury (20 patients; 9 [36.0%] with an occult fracture line and 11 [44.0%] with bone bruising). In longitudinal image, the mean value of the PQ thickness of affected hands was 6.2 (3.7–9.6 mm; standard deviation [SD], 1.5) and that of unaffected hands was 4.5 (2.3–6.7 mm; SD, 1.2), respectively. In transverse image, that of dominant and nondominant hands was 7.6 (4.6–13.2 mm; SD, 2.0) and 5.5 (3.6–7.5 mm; SD, 1.1), respectively. The mean difference in PQ thickness between affected and unaffected hands was 1.7 (0.1–5.0 mm; SD, 1.1) in longitudinal image and 2.0 (0.3–6.8 mm; SD, 1.7) in transverse image

  20. Catecholamines, Plasma and Urine Test

    Science.gov (United States)

    ... and Iron-binding Capacity (TIBC, UIBC) Trichomonas Testing Triglycerides Troponin Tryptase Tumor Markers Uric Acid Urinalysis Urine ... blood pressure, and epinephrine increases heart rate and metabolism . After completing their actions, catecholamines are metabolized to ...

  1. Psychopathology and urine toxicology in methadone patients

    Directory of Open Access Journals (Sweden)

    Gamal Sadek

    2015-06-01

    Full Text Available Several studies reported high rates of psychiatric commorbidity among methadone patients. We examined the relationships of measures of psychopathology to outcomes of screening urine tests for cocaine, opiates, and benzodiazepines in a sample of 56 methadone patients. They also completed the Symptom Check List-90-Revised (SCL-90-R. The highest scales in the SCL-90-R profile of our patients were those indicating somatic discomfort, anger, phobic anxiety, paranoid ideation, and also obsessive-compulsive disorder symptoms (scores above the 39th percentile. The only significant correlations between urine tests and SCL-90-R psychopathology were those involving benzodiazepines: patients with urine tests positive for benzodiazepines had lower social self-confidence (r=0.48, were more obsessive-compulsive (r=0.44, reported a higher level of anger (r=0.41, of phobic tendencies (r=40, of anxiety (r=0.39, and of paranoid tendencies (r=0.38, and also reported more frequent psychotic symptoms (r=0.43.

  2. Effects of electrotherapy in treatment of neurogenic bladder in children with occult spinal dysraphism

    Directory of Open Access Journals (Sweden)

    Ćirović Dragana

    2009-01-01

    Full Text Available Introduction Neurogenic bladder can develop as a result of various degrees of neurogenic lesion in spina bifida. The degree of bladder dysfunction depends on the level and type of spina bifida. Due to results upon complete diagnostic protocols, treatment options are applied. Objective Comparison of therapy results of patients with occult spinal dysraphism with neurogenic bladder that under-went medicamentous therapy and medicamentous with electrotherapy treatment. Methods We had 49 patients with neurogenic bladder that were treated at the University Children's Hospital in Belgrade in the period 2003-2008. The first group of children received medicamentous therapy and the second group received medicamentous therapy with transcutaneous electric nerve stimulation. In both groups we evaluated 4 symptoms: daily enuresis, enuresis nocturna, urgency and frequency and 4 urodynamic parameters: lower bladder capacity, unstable contractions and residual urine and detrusor sphincter dyssynergia. Follow-up urodynamic evaluation was done after 3, 6 and 12 months respectively. Results Our findings pointed out a high statistical significance of improvement in all evaluated urodynamic parameters of neurogenic bladder (predominantly in bladder capacity in the group of children with combined therapy as well in resolution of symptoms (predominantly enuresis nocturna, urgency and frequency. Conclusion Combined therapy is more efficient in treatment of children with neurogenic bladder. Electrotherapy is non-invasive, easily applicable and has had a significant place in treatment of children with dysfunctional voiding.

  3. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  4. Lack of clinical utility of urine gram stain for suspected urinary tract infection in pediatric patients.

    Science.gov (United States)

    Cantey, Joseph B; Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D

    2015-04-01

    Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P=0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P=0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. Evaluation of Refractivity Profiles from CHAMP and SAC-C GPS Radio Occultation

    Science.gov (United States)

    Poli, Paul; Ao, Chi On; Joiner, Joanna; delaTorreJuarez, Manuel; Hoff, Raymond

    2002-01-01

    The GeoForschungsZentrum's Challenging Minisatellite Payload for Geophysical Research and Application (CHAMP, Germany-US) and the Comision Nacional de Actividades Especiales' Satelite de Aplicaciones Cientificas-C (SAC-C, Argentina-US) missions are the first missions to carry a second-generation Blackjack Global Positioning System (GPS) receiver. One of the new features of this receiver is its ability to sense the lower troposphere closer to the surface than the proof-of-concept GPS Meteorology experiment (GPS/MET). Since their launch, CHAMP and SAC-C have collected thousands of GPS radio occultations, representing a wealth of measurements available for data assimilation and Numerical Weather Prediction (NWP). In order to evaluate the refractivity data derived by the Jet Propulsion Laboratory (JPL) from raw radio occultation measurements, we use Data Assimilation Office (DAO) 6-hour forecasts as an independent state of the atmosphere. We compare CHAMP and SAC-C refractivity (processed by JPL) with refractivity calculated from the DAO global fields of temperature, water vapor content and humidity. We show statistics of the differences as well as histograms of the differences.

  6. Taiwan/TriG Radio Occultation Process System (TROPS): A Brief Introduction of Atmospheric Productions

    Science.gov (United States)

    Huang, Cheng-Yung; Yeh, Wen-Hao; Tseng, Tzu-Pang; Chen, Linton J.

    2017-04-01

    Global Positioning System (GPS) Radio Occultation (RO) technique has been used to investigate the Earth's atmosphere since 1990s. In 2006, Taiwan has launched six low Earth orbit (LEO) satellites as a RO constellation mission, named FORMOSAT-3 /COSMIC (F-3/C). F-3/C mission can release 1500-2500 data sets per day for both neutral atmosphere and ionosphere. With the advent of Global Navigation Satellite System (GNSS) in ten years and FORMOSAT-7/COSMIC-2 (F-7/C-2) mission, 12 LEO satellites are planned to be launched and deployed in two clusters of 6-satellites into the designated low and high inclination orbits in 2017 and 2020(TBD), respectively. The amount of RO data set will increase to about 8000 set per day with the using of GNSS TriG (GPS, Glonass, Galileo) receivers. The first phase of FS-7 mission is designed to low inclination (24 deg) orbit to improve the ability of server weather forecasting, like typhoon and monsoon rainfall around tropical region. The second is high inclination (72 deg) for global distribution. In order to observe better water vapor profiles, the 4x3 antennas arrays will be on board to receive weak signals which pass through low troposphere around earth surface. This report will introduce the status of F-7/C-2 mission and atmospheric part of occultation data process software TROPS.

  7. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  8. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    2001-01-01

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  9. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    Science.gov (United States)

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps

  10. Titan's Surface Composition from Cassini VIMS Solar Occultation Observations

    Science.gov (United States)

    McCord, Thomas; Hayne, Paul; Sotin, Christophe

    2013-04-01

    Titan's surface is obscured by a thick absorbing and scattering atmosphere, allowing direct observation of the surface within only a few spectral win-dows in the near-infrared, complicating efforts to identify and map geologi-cally important materials using remote sensing IR spectroscopy. We there-fore investigate the atmosphere's infrared transmission with direct measure-ments using Titan's occultation of the Sun as well as Titan's reflectance measured at differing illumination and observation angles observed by Cas-sini's Visual and Infrared Mapping Spectrometer (VIMS). We use two im-portant spectral windows: the 2.7-2.8-mm "double window" and the broad 5-mm window. By estimating atmospheric attenuation within these windows, we seek an empirical correction factor that can be applied to VIMS meas-urements to estimate the true surface reflectance and map inferred composi-tional variations. Applying the empirical corrections, we correct the VIMS data for the viewing geometry-dependent atmospheric effects to derive the 5-µm reflectance and 2.8/2.7-µm reflectance ratio. We then compare the cor-rected reflectances to compounds proposed to exist on Titan's surface. We propose a simple correction to VIMS Titan data to account for atmospheric attenuation and diffuse scattering in the 5-mm and 2.7-2.8 mm windows, generally applicable for airmass water ice for the majority of the low-to-mid latitude area covered by VIMS measurements. Four compositional units are defined and mapped on Titan's surface based on the positions of data clusters in 5-mm vs. 2.8/2.7-mm scatter plots; a simple ternary mixture of H2O, hydrocarbons and CO2 might explain the reflectance properties of these surface units. The vast equatorial "dune seas" are compositionally very homogeneous, perhaps suggesting transport and mixing of particles over very large distances and/or and very consistent formation process and source material. The composi-tional branch characterizing Tui Regio and Hotei Regio is

  11. A variational regularization of Abel transform for GPS radio occultation

    Directory of Open Access Journals (Sweden)

    T.-K. Wee

    2018-04-01

    Full Text Available In the Global Positioning System (GPS radio occultation (RO technique, the inverse Abel transform of measured bending angle (Abel inversion, hereafter AI is the standard means of deriving the refractivity. While concise and straightforward to apply, the AI accumulates and propagates the measurement error downward. The measurement error propagation is detrimental to the refractivity in lower altitudes. In particular, it builds up negative refractivity bias in the tropical lower troposphere. An alternative to AI is the numerical inversion of the forward Abel transform, which does not incur the integration of error-possessing measurement and thus precludes the error propagation. The variational regularization (VR proposed in this study approximates the inversion of the forward Abel transform by an optimization problem in which the regularized solution describes the measurement as closely as possible within the measurement's considered accuracy. The optimization problem is then solved iteratively by means of the adjoint technique. VR is formulated with error covariance matrices, which permit a rigorous incorporation of prior information on measurement error characteristics and the solution's desired behavior into the regularization. VR holds the control variable in the measurement space to take advantage of the posterior height determination and to negate the measurement error due to the mismodeling of the refractional radius. The advantages of having the solution and the measurement in the same space are elaborated using a purposely corrupted synthetic sounding with a known true solution. The competency of VR relative to AI is validated with a large number of actual RO soundings. The comparison to nearby radiosonde observations shows that VR attains considerably smaller random and systematic errors compared to AI. A noteworthy finding is that in the heights and areas that the measurement bias is supposedly small, VR follows AI very closely in the

  12. A variational regularization of Abel transform for GPS radio occultation

    Science.gov (United States)

    Wee, Tae-Kwon

    2018-04-01

    In the Global Positioning System (GPS) radio occultation (RO) technique, the inverse Abel transform of measured bending angle (Abel inversion, hereafter AI) is the standard means of deriving the refractivity. While concise and straightforward to apply, the AI accumulates and propagates the measurement error downward. The measurement error propagation is detrimental to the refractivity in lower altitudes. In particular, it builds up negative refractivity bias in the tropical lower troposphere. An alternative to AI is the numerical inversion of the forward Abel transform, which does not incur the integration of error-possessing measurement and thus precludes the error propagation. The variational regularization (VR) proposed in this study approximates the inversion of the forward Abel transform by an optimization problem in which the regularized solution describes the measurement as closely as possible within the measurement's considered accuracy. The optimization problem is then solved iteratively by means of the adjoint technique. VR is formulated with error covariance matrices, which permit a rigorous incorporation of prior information on measurement error characteristics and the solution's desired behavior into the regularization. VR holds the control variable in the measurement space to take advantage of the posterior height determination and to negate the measurement error due to the mismodeling of the refractional radius. The advantages of having the solution and the measurement in the same space are elaborated using a purposely corrupted synthetic sounding with a known true solution. The competency of VR relative to AI is validated with a large number of actual RO soundings. The comparison to nearby radiosonde observations shows that VR attains considerably smaller random and systematic errors compared to AI. A noteworthy finding is that in the heights and areas that the measurement bias is supposedly small, VR follows AI very closely in the mean refractivity

  13. Digital solar edge tracker for the Halogen Occultation Experiment

    Science.gov (United States)

    Mauldin, L. E., III; Moore, A. S.; Stump, C. W.; Mayo, L. S.

    1987-01-01

    The optical and electronic design of the Halogen Occultation Experiment (Haloe) elevation sun sensor is described. The Haloe instrument is a gas-correlation radiometer now being developed at NASA Langley for the Upper Atmosphere Research Satellite. The system uses a Galilean telescope to form a solar image on a linear silicon photodiode array. The array is a self-scanned monolithic CCD. The addresses of both solar edges imaged on the array are used by the control/pointing system to scan the Haloe science instantaneous field of view (IFOV) across the vertical solar diameter during instrument calibration and then to maintain the science IFOV 4 arcmin below the top edge during the science data occultation event. Vertical resolution of 16 arcsec and a radiometric dynamic range of 100 are achieved at the 700-nm operating wavelength. The design provides for loss of individual photodiode elements without loss of angular tracking capability.

  14. Sensitivity of GPS occultation to the stratopause height

    DEFF Research Database (Denmark)

    Schrøder, Thomas Morville; Ao, Chi; de la Torre Juárez, Manuel

    2007-01-01

    We scrutinize temperature profiles collected with radio occultation measurement for an imprint of the stratopause. In the retrieval step that integrates bending angle data to atmospheric refractivity, the falloff toward infinite altitude is constrained in a boundary condition with statistical opt...... rate, not isothermal conditions. Keeping the model seed for temperature conversion to subsequent retrieval steps eliminates external information from the deconvolved refractivity. It will help argue for radio occultation as independent vehicle for climate monitoring....... height gradient. On the basis of noise free simulation using a climatology covering all latitudes, seasons, and hours and on the basis of validation against data collected with weather balloons, laser imaging, and limb sounding, we find that adaptation to the fluctuating stratopause is crucial...

  15. Dusty Dwarfs Galaxies Occulting A Bright Background Spiral

    Science.gov (United States)

    Holwerda, Benne

    2017-08-01

    The role of dust in shaping the spectral energy distributions of low mass disk galaxies remains poorly understood. Recent results from the Herschel Space Observatory imply that dwarf galaxies contain large amounts of cool (T 20K) dust, coupled with very modest optical extinctions. These seemingly contradictory conclusions may be resolved if dwarfs harbor a variety of dust geometries, e.g., dust at larger galactocentric radii or in quiescent dark clumps. We propose HST observations of six truly occulting dwarf galaxies drawn from the Galaxy Zoo catalog of silhouetted galaxy pairs. Confirmed, true occulting dwarfs are rare as most low-mass disks in overlap are either close satellites or do not have a confirmed redshift. Dwarf occulters are the key to determining the spatial extent of dust, the small scale structure introduced by turbulence, and the prevailing dust attenuation law. The recent spectroscopic confirmation of bona-fide low mass occulting dwarfs offers an opportunity to map dust in these with HST. What is the role of dust in the SED of these dwarf disk galaxies? With shorter feedback scales, how does star-formation affect their morphology and dust composition, as revealed from their attenuation curve? The resolution of HST allows us to map the dust disks down to the fine scale structure of molecular clouds and multi-wavelength imaging maps the attenuation curve and hence dust composition in these disks. We therefore ask for 2 orbits on each of 6 dwarf galaxies in F275W, F475W, F606W, F814W and F125W to map dust from UV to NIR to constrain the attenuation curve.

  16. [Occult pneumothorax: Does it take drain before elective surgery?].

    Science.gov (United States)

    Bensghir, M; Moutaoukil, M; Meziane, M; Jaafari, A; Hemmaoui, B; Haimeur, C

    2016-08-01

    Pneumothorax occult is defined by the presence of a non-visible to standard asymptomatic pneumothorax and pulmonary diagnosed only by X-ray computed tomography. The presence of this type of pneumothorax before planned surgery is a rare situation. What to do remains non-consensual. Through two clinic cases and a literature review, the authors discuss the modalities of management of this entity. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Implementation of immunochemical faecal occult blood test in general practice

    DEFF Research Database (Denmark)

    Juul, Jakob Søgaard; Bro, Flemming; Hornung, Nete

    2016-01-01

    anvendelsen af immunochemical faecal occult blood test (iFOBT) i almen praksis. iFOBT detekterer humant globin i fæces og indikerer gastrointestinal blødning. Studiet udgør en del af et ph.d.-studie, der bidrager med ny viden til at optimere udredningen af patienter med tarmkræft. Der er et stort behov...

  18. Performance of Urinary Markers for Detection of Upper Tract Urothelial Carcinoma: Is Upper Tract Urine More Accurate than Urine from the Bladder?

    Directory of Open Access Journals (Sweden)

    Simone Bier

    2018-01-01

    Full Text Available Objectives. To assess the performance of urine markers determined in urine samples from the bladder compared to samples collected from the upper urinary tract (UUT for diagnosis of UUT urothelial carcinoma (UC. Patients and Methods. The study comprised 758 urine samples either collected from the bladder (n=373 or UUT (n=385. All patients underwent urethrocystoscopy and UUT imaging or ureterorenoscopy. Cytology, fluorescence in situ hybridization (FISH, immunocytology (uCyt+, and nuclear matrix protein 22 (NMP22 were performed. Results. UUT UC was diagnosed in 59 patients (19.1% (UUT urine and 27 patients (7.2% (bladder-derived urine. For UUT-derived samples, sensitivities for cytology, FISH, NMP22, and uCyt+ were 74.6, 79.0, 100.0, and 100.0, while specificities were 66.6, 50.7, 5.9, and 66.7%, respectively. In bladder-derived samples, sensitivities were 59.3, 52.9, 62.5, and 50.0% whereas specificities were 82.9, 85.0, 31.3, and 69.8%. In UUT-derived samples, concomitant bladder cancer led to increased false-positive rates of cytology and FISH. Conclusions. Urine markers determined in urine collected from the UUT exhibit better sensitivity but lower specificity compared to markers determined in bladder-derived urine. Concomitant or recent diagnosis of UC of the bladder can further influence markers determined in UUT urine.

  19. Lunar occultation observation of μ Sgr: A progress report

    Energy Technology Data Exchange (ETDEWEB)

    Jatmiko, A. T. P. [Bosscha Observatory, Institut Teknologi Bandung (Indonesia); Puannandra, G. P.; Hapsari, R. D.; Putri, R. A.; Arifin, Z. M.; Haans, G. K.; Hadiputrawan, I. P. W. [Bosscha Observatory, Institut Teknologi Bandung, Indonesia and Astronomy Study Program, Institut Teknologi Bandung (Indonesia)

    2014-03-24

    Lunar Occultation (LO) is an event where limb of the Moon passing over a particular heavenly bodies such as stars, asteroids, or planets. In other words, during the event, stars, asteroids and planets are occulted by the Moon. When occulted objects contact the lunar limb, there will be a diffraction fringe(s) which can be measured photometrically, until the signal vanishes into noise. This event will give us a valuable information about binarities (of stars) and/or angular diameters estimation (of stars, planets, asteroids) in milliarcsecond resolution, by fitting with theoretical LO pattern. CCDs are common for LO observation because of its fast read out, and recently are developed for sub-meter class telescope. In this paper, our LO observation attempt of μ Sgr and its progress report are presented. The observation was conducted on July 30{sup th}, 2012 at Bosscha Observatory, Indonesia, using 45cm f/12 GOTO telescope combined with ST-9 XE CCD camera and Bessel B filter. We used drift-scan method to obtain light curve of the star as it was disappearing behind Moon's dark limb. Our goal is to detect binarity (or multiplicity) of this particular object.

  20. Urine Sodium in 3 Consecutive Days Urine collected from ...

    African Journals Online (AJOL)

    Epidemiological and experimental studies have shown that salt sensitivity, which is a heritable trait, is a hallmark to hypertension in blacks. Previous studies on twenty-four hour urinary sodium were either incomplete or yielded contradictory results possibly from incomplete urine collection. This study attempted complete ...

  1. Developing an Optical Lunar Occultation Measurement Reduction System for Observations at Kaau Observatory

    Science.gov (United States)

    Malawi, Abdulrahman A.

    2013-06-01

    We present here a detailed explanation of the reduction method that we use to determine the angular diameters of the stars occulted by the dark limb of the moon. This is a main part of the lunar occultation observation program running at King Abdul Aziz University observatory since late 1993. The process is based on the least square model fitting method of analyzing occultation data, first introduced by Nather et al. (Astron. J. 75:963, 1970).

  2. Lunar occultation of Saturn. IV - Astrometric results from observations of the satellites

    Science.gov (United States)

    Dunham, D. W.; Elliot, J. L.

    1978-01-01

    The method of determining local lunar limb slopes, and the consequent time scale needed for diameter studies, from accurate occultation timings at two nearby telescopes is described. Results for photoelectric observations made at Mauna Kea Observatory during the occultation of Saturn's satellites on March 30, 1974, are discussed. Analysis of all observations of occultations of Saturn's satellites during 1974 indicates possible errors in the ephemerides of Saturn and its satellites.

  3. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography

    OpenAIRE

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    Backgraound An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the useful...

  4. Substitution of human for horse urine disproves an accusation of doping*.

    Science.gov (United States)

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  5. Bladder squamous cell carcinomas express psoriasin and externalize it to the urine

    DEFF Research Database (Denmark)

    Celis, J E; Rasmussen, H H; Vorum, H

    1996-01-01

    were confined chiefly to the "squamous pearls." The presence of psoriasin in the urine of the 4 SCC patients was demonstrated by two-dimensional gel immunoblotting. Similar analysis of 43 urines from patients with bladder tumors other than SCC revealed 7 positives, some of which may reflect squamous...

  6. Upper Troposphere Lower Stratosphere structure during convective systems using GPS radio occultations

    DEFF Research Database (Denmark)

    Biondi, Riccardo

    The deep convective systems play a fundamental role in atmospheric circulation and climate. Thunderstorms and meso-scale convective systems produce fast vertical transport, redistributing water vapor and trace gases and influencing the thermal structure of the upper troposphere and lower...... stratosphere (UTLS) contributing to the troposphere-stratosphere transport and affecting the Earth global circulation and the climate changes. The Global Positioning System (GPS) Radio Occultation (RO) technique enables measurement of atmospheric density structure in any meteorological condition...... to the analysis of tropical storms for the future mission ACES will also be evaluated. Using data from the past and ongoing GPS RO missions we have defined an algorithm to detect the clouds top of the convective systems and their thermal structure. Other satellite and in-situ measurements co-located with GPS ROs...

  7. CORRELATION OF SPOT URINE ALBUMIN AND 12-HOUR URINE PROTEIN WITH 24-HOUR URINE PROTEIN IN PRE-ECLAMPSIA

    Directory of Open Access Journals (Sweden)

    S. Vinayachandran

    2017-11-01

    Full Text Available BACKGROUND Pre-eclampsia is defined as the development of new-onset hypertension in the second half of pregnancy often accompanied by new-onset proteinuria with other signs and symptoms. Proteinuria is defined by the excretion of 300 mg or more of protein in a 24-hour urine collection. To avoid time consumed in collection of 24-hour urine specimens, efforts have been made to develop faster methods to determine concentration of urine protein. Preliminary studies have suggested that 12-hour urine protein collection maybe adequate for evaluation of pre-eclampsia with advantage of early diagnosis and treatment of pre-eclampsia as well as potential for early hospital discharge and increased compliance with specimen collection. The aim of the study is to evaluate and correlate spot urine albumin and 12-hour urine protein with 24-hour urine protein in pre-eclampsia. MATERIALS AND METHODS A diagnostic evaluation study- a 24-hour urine protein, 12-hour urine protein and spot urine albumin results are analysed. Correlation of 12-hour urine protein and spot urine albumin with 24-hour urine protein is analysed using SPSS software. The strength of correlation was measured by Pearson’s correlation coefficient (r. Student’s t-test and Chi-square tests were used to compare patients with and without 24-hour urine protein ≥300 mg. Probability value of 165 mg with 24-hour urine protein ≥300 mg suggest that this test has role in the evaluation of women with suspected pre-eclampsia and could be substituted for 24-hour urine protein as a simple, faster and cheaper method.

  8. Nonhazardous Urine Pretreatment Method for Future Exploration Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A novel urine pretreatment that will prevent biological growth or chemical instabilities in urine without using hazardous chemicals is proposed. Untreated urine...

  9. Prevalence of occult hepatitis C virus infection in the Iranian patients with human immunodeficiency virus infection.

    Science.gov (United States)

    Bokharaei-Salim, Farah; Keyvani, Hossein; Esghaei, Maryam; Zare-Karizi, Shohreh; Dermenaki-Farahani, Sahar-Sadat; Hesami-Zadeh, Khashayar; Fakhim, Shahin

    2016-11-01

    Occult hepatitis C virus (HCV) infection is a new form of chronic HCV infection described by the presence of the genomic HCV-RNA in liver biopsy and/or peripheral blood mononuclear cell (PBMC) samples, and undetectable levels or absence of HCV-RNA and in the absence or presence of anti HCV antibodies in the plasma specimens. The aim of the present study was to evaluate the occurrence of occult HCV infection (OCI) among Iranian subjects infected with human immunodeficiency virus (HIV) using RT-nested PCR. From March 2014 until April 2015, 109 Iranian patients with established HIV infection were enrolled in this cross-sectional study. After extraction of viral RNA from the plasma and PBMC samples, HCV-RNA status was examined by RT-nested PCR using primers from the 5'-NTR. HCV genotyping was conducted using RFLP analysis. For the confirmation of HCV genotyping by RFLP method, the PCR products were sequenced. Of the 109 patients, 50 were positive for antibodies against HCV. The HCV-RNA was detected in PBMC specimens in 6 (10.2%) out of the total 59 patients negative for anti-HCV Abs and undetectable plasma HCV-RNA and also from 4 (8.0%) out of the total 50 patients positive for anti-HCV Abs and undetectable plasma HCV-RNA. HCV genotyping analysis showed that 6 (60.0%) patients were infected with HCV subtype 3a, 3 (30.0%) were infected with HCV subtype 1a and 1 (10.0%) patient was infected with HCV subtype 1b. This study revealed the incidence of OCI (9.2%) in HIV-infected Iranian patients. Hence, designing prospective studies focusing on the detection of OCI in these patients would provide more information. J. Med. Virol. 88:1960-1966, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Ultra-High Resolution Orbit Determination of (486958) 2014 MU69: Predicting an Occultation with 1% of an Orbit

    Science.gov (United States)

    Porter, Simon Bernard; Buie, Marc W.; Spencer, John R.; Folkner, William; Parker, Alex; Zangari, Amanda Marie; Verbiscer, Anne J.; Benecchi, Susan; Stern, S. Alan; Terrell, Dirk; Soto, Alejandro; Tamblyn, Peter; Wasserman, Lawrence H.; Young, Eliot F.; New Horizons MU69 Occultation Team

    2017-10-01

    In November 2015, the NASA New Horizons spacecraft burned its thrusters to intercept the cold classical Kuiper Belt Object (486958) 2014 MU69. Then, on July 17, 2017, five small telescopes in Chubut Province, Argentina recorded a solid body occultation of MU69. Both these events required an orbital solution of unprecedented accuracy, as will the January 1, 2019 flyby of MU69 by New Horizons. This was especially difficult because there were no precoveries of MU69 prior to July 2014, it is in an extremely crowded field near the galactic core, and it is faint enough to only be reliably detected by Hubble Space Telescope’s Wide Field Camera 3 (WFC3). To accomplish this, we performed an extremely detailed analysis of 237 WFC3 images, down to the subpixel distortion level, in order to produce individual probability distribution functions (PDFs) for the position of MU69 in each WFC3 image. We registered each WFC3 image against a pre-release version of the Gaia DR2 catalog, which produced even smaller residuals than the now-released DR1. We then combined these WFC3+Gaia PDFs with a high-precision few-body numerical integrator and a Monte Carlo Markov Chain (MCMC) sampler to produce a state vector PDF for MU69 at defined epoch. Propagating those state vectors from the epoch produces an instantaneous positional cloud for MU69 at any given time. This positional cloud was then directly translated into a shadow path uncertainty cloud in order to plan the MU69 occultation campaign. We will describe this process of fully propagating errors from WFC3 images to telescope sites on the ground, and also describe refinements for future guiding of New Horizons to its encounter with MU69. We thank NASA, Hubble, Gaia, CONAE, the city of Comodoro Rivadavia, and the government of Argentina for their assistance and support of the MU69 occultation campaign.

  11. Residual urine output and postoperative mortality in maintenance hemodialysis patients.

    Science.gov (United States)

    Lin, Yu-Feng; Wu, Vin-Cent; Ko, Wen-Je; Chen, Yih-Sharng; Chen, Yung-Ming; Li, Wen-Yi; Chou, Nai-Kuan; Chao, Anne; Huang, Tao-Min; Chang, Fan-Chi; Chen, Shih-I; Shiao, Chih-Chung; Wang, Wei-Jie; Tsai, Hung-Bin; Tsai, Pi-Ru; Hu, Fu-Chang; Wu, Kwan-Dun

    2009-09-01

    The relationship between residual urine output and postoperative survival in maintenance hemodialysis patients is unknown. To explore the relationship between amount of urine before surgery and postoperative mortality and differences between postoperative nonanuria and anuria in maintenance hemodialysis patients. A total of 109 maintenance hemodialysis patients underwent major operations. Anuria was defined as urine output <30 mL in the 8 hours before the first session of postoperative dialysis. Propensity scores for postoperative anuria were developed. Postoperative residual urine output was 159.2 mL/8 h (SD, 115.1) in 33 patients; 76 patients were anuric. Preoperative residual urine output and adequate perioperative blood transfusion were positively related to postoperative urine output. Propensity-adjusted 30-day mortality was associated with postoperative anuria (odds ratio [OR], 4.56; 95% confidence interval [CI], 1.16-17.96; P = .03), prior stroke (OR, 4.46; 95% CI, 1.43-13.89; P = .01) and higher disease severity (OR, 1.10; 95% CI, 1.00-1.21; P = .049) at the first postoperative dialysis. OR of 30-day mortality was 5.38 for nonanuria to anuria vs nonanuria to nonanuria (P = .03) and 5.13 for preoperative anuria vs nonanuria to nonanuria (P = .01). By Kaplan-Meier analysis, 30-day mortality differed significantly among patients for nonanuria to nonanuria, anuria, and nonanuria to anuria (log rank, P = .045). Patients with preoperative nonanuria and postoperative anuria had higher mortality than did patients with no anuria before and after surgery and patients with anuria before surgery. Postoperative residual urine output is an important surrogate marker for disease severity.

  12. Genomic variability associated with the presence of occult hepatitis B virus in HIV co-infected individuals

    OpenAIRE

    Martin, C. M.; Welge, J. A.; Shire, N. J.; Rouster, S. D.; Shata, M. T.; Sherman, K. E.; Blackard, J. T.

    2009-01-01

    Occult hepatitis B virus (O-HBV) infection is characterized by the presence of HBV DNA without detectable hepatitis B surface antigen (HBV DNA+/HBsAg−) in the serum. Although O-HBV is more prevalent during HBV/HIV co-infection, analysis of HBV mutations in co-infected patients is limited. In this preliminary study, HBV PreSurface (PreS) and surface (S) regions were amplified from 33 HIV-positive patient serum samples − 27 chronic HBV (C-HBV) and six O-HBV infections. HBV genotype was determin...

  13. Measurements of the upper troposphere and lower stratosphere during tropical cyclones using the GPS radio occultation technique

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Neubert, Torsten; Syndergaard, Stig

    2011-01-01

    and Climate (COSMIC) were analyzed, focusing on two particular tropical cyclones with completely different characteristics, the hurricane Bertha, which formed in the Atlantic Basin during July 2008 and reached a maximum intensity of Category 3, and the typhoon Hondo, which formed in the south Indian Ocean...... during 2008 reaching a maximum intensity of Category 4. The result is positive, suggesting that the bending angle of a GPS radio occultation signal contains interesting information on the atmosphere around the tropopause, but not any information regarding the water vapour. The maximum percentage anomaly...

  14. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    Science.gov (United States)

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  15. From darkening urine to early diagnosis of alkaptonuria

    Directory of Open Access Journals (Sweden)

    Peker Erdal

    2008-01-01

    Full Text Available Alkaptonuria is a rare disorder of metabolism characterized by deficiency of homogentisic acid oxidase. Characteristic features include darkening of urine, ochronosis, and arthropathy. Darkening of urine is the only sign of the disorder in the pediatric age group, and it occurs at very early stage of the disorder, as reported by the parents. A 4-year-old boy presented to our clinic with the complaint of dark urine and bluish black staining of clothes. This darkening pointed to a positive physical history of bluish discoloration of sclerae which occurred off and on. We initiated treatment with ascorbic acid and a protein diet with restriction of phenylalanine and tyrosine (1.6 g/kg/d. This case report is significant because of the early diagnosis made.

  16. Nutrient and energy recovery from urine

    NARCIS (Netherlands)

    Kuntke, P.

    2013-01-01

    Keywords: urine, urine treatment, nutrient recovery, microbial fuel cells, energy production from urine, membrane capacitive deionization.

    In conventional wastewater treatment plants large amounts of energy are required for the removal and recovery of nutrients (i.e. nitrogen and

  17. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    Science.gov (United States)

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  18. Bisphenol A levels in human urine.

    Science.gov (United States)

    Matsumoto, Akiko; Kunugita, Naoki; Kitagawa, Kyoko; Isse, Toyohi; Oyama, Tsunehiro; Foureman, Gary L; Morita, Masatoshi; Kawamoto, Toshihiro

    2003-01-01

    The estrogenic effects of bisphenol A (BPA) have been reported in human cells (E-screen assays) and in (italic)in vivo(/italic) studies of rodents, although the latter reports remain controversial, as do the exposure levels and adverse health effects of BPA in humans. In this study we report on an analytical high-performance liquid chromatography/fluorescence method for BPA and its conjugate in human urine and on the application of this method in two student cohorts. Urine, along with information on smoking, alcohol intake, and coffee/tea consumption, was collected in two different years from two different groups of university students, 50 in 1992 and 56 in 1999. Overall, the urinary BPA levels in the students in 1992 were significantly higher than were those in 1999. The BPA levels were also positively correlated with coffee and tea consumption in the 1992 cohort but not in the 1999 cohort. We speculate that recent changes made in Japan regarding the interior coating of cans used to package these beverages may partly explain these findings. PMID:12515686

  19. [Management of occult malformations at the lateral skull base].

    Science.gov (United States)

    Bryson, E; Draf, W; Hofmann, E; Bockmühl, U

    2005-12-01

    Occult malformations of the lateral skull base are rare anomalies, but can cause severe complications such as recurrent meningitis. Therefore, they need to be precisely delineated and sufficient surgical closure is mandatory. Between 1986 and 2004 twenty patients (10 children and 10 adults) with occult malformations at the lateral skull base were treated surgically at the ENT-Department of the Hospital Fulda gAG. Of these 3 Mondini-malformations, 11 defects of the tegmen tympani or the mastoidal roof, 2 dural lesions to the posterior fossa and 4 malformations within the pyramidal apex have been found. Four patients have had multiple anomalies. Routing symptom was in all cases at least one previous meningitis. Radiological diagnostics included high-resolution computed tomography (CT) and magnetic resonance imaging (MRI) as well as CT- or MR-cisternography. Depending on type and localisation of the defect the following surgical algorithm was carried out: The trans-mastoidal approach was used in all cases of Mondini-malformation (including obliteration of the ear), in case of lesions to the posterior fossa as well as partly in anomalies at the tegmen tympani and mastoidal roof, respectively. Defects of the pyramidal apex should be explored via the trans-mastoidal way if the lesion is located caudally to the inner auditory canal (IAC), whereas the trans-temporal approach should be used if the lesion is situated ventral to the IAC and dorso-medially to the internal carotid artery (ICA). The trans-temporal approach was also performed in large defects of the tegmen tympani and mastoidal roof as well as in recurrences. In all cases of recurrent meningitis caused by agents of the upper airway tract the basic principle should be to search for occult skull base malformations radiologically as well as by sodium fluorescein endoscopy as long as the anomaly is detected.

  20. A 2017 stellar occultation by Orcus/Vanth

    Science.gov (United States)

    Sickafoose, Amanda A.; Bosh, Amanda S.; Levine, Stephen; Zuluaga, Carlos A.; Genade, Anja; Schindler, Karsten; Lister, Tim; Person, Michael J.

    2017-10-01

    (90482) Orcus is a large trans-Neptunian object (TNO) of diameter ~900 km, located in the 3:2 orbital resonance with Neptune. This plutino has a satellite, Vanth, approximately 280 km in diameter. Vanth orbits roughly 9000 km from Orcus in a ~9.5-day period. This system is particularly interesting, as Orcus falls between the small, spectrally-bland TNOs and the large TNOs having spectra rich in volatile features, while Vanth might have resulted from either collision or capture.A stellar occultation by Orcus was predicted to occur on 07 March 2017. Observations were made from five sites: the 0.6-m Astronomical Telescope of the University of Stuttgart (ATUS) at Sierra Remote Observatories (SRO), California; Las Cumbres Observatory’s 1-m telescope (ELP) at McDonald Observatory, Fort Davis, Texas; NASA’s 3-m InfraRed Telescope Facility (IRTF) on Mauna Kea, Hawaii; the 4.1-m Southern Astrophysical Research telescope (SOAR) on Cerro Pachón, Chile; and the 0.6-m Southeastern Association for Research in Astronomy telescope (SARA-CT) at Cerro Tololo, Chile. High-speed, visible-wavelength images were taken at all sites, in addition to simultaneous K-band images at the IRTF. A solid-body occultation was observed at both ELP and the IRTF. Offset midtimes and incompatible light ratios suggest that two different stars were occulted by two different bodies, likely Orcus and Vanth. See Bosh et al. this conference for details of the astrometry for the event. Here, we present results from the observations, including light curves, size and albedo estimates, and upper limits on a possible atmosphere.

  1. La place des sciences occultes et de la parapsychologie dans les bibliothèques : problèmes déontologiques et bibliothéconomiques

    OpenAIRE

    Benoist, David; Brault, Julien; Soret, David; Weill, Chantal

    2006-01-01

    Publications of occult sciences and parapsychology give particular problems in libraries. What are the deontological positions that librarians have to adopt concerning works for which references miss and whose seriousness is sometimes contestable? Censoring is tempting but contradicts the encyclopaedic mission. Esoteric works also raise practical questions in terms of biblioeconomy: the limits of the domain are not always defined and their definition requires specific tools. The choices to be...

  2. Multiple surface antigen mutations in five blood donors with occult hepatitis B virus infection

    NARCIS (Netherlands)

    Zaaijer, H. L.; Torres, P.; Ontañón, A.; Ponte, L. González; Koppelman, M. H. G. M.; Lelie, P. N.; Hemert, F. J. van; Boot, H. J.

    2008-01-01

    Occult hepatitis B virus (HBV) infection is characterized by the presence of HBV DNA while the HBV surface antigen (HBsAg) remains undetectable. The HBV genomes in five asymptomatic blood donors with occult HBV infection and low viremia ( <10 to 1,000 HBV DNA copies/mL, genotype D) were studied. An

  3. Trio of Stellar Occultations by Pluto One Year Prior to New Horizons’ Arrival

    Science.gov (United States)

    2016-04-02

    stellar signal, both with 20 s exposures with our frame-transfer Portable Occultation, Eclipse, and Transit System. Since Pluto had a geocentric velocity...and for New Horizons’s 2015 approach . For the July 31 event, though for our atmospheric studies we are glad to have detected the occultation of this

  4. Combined parathyroid adenoma and an occult papillary carcinoma

    International Nuclear Information System (INIS)

    Meshikhes, Abdul-Wahid N.; Al-Saihati, Basima A.; Butt, Mohammad S.

    2004-01-01

    Although the pathological association of thyroid and parathyroid disease is common, the association of both parathyroid adenoma and thyroid cancer is rare. We report here a case of a 45-year-old saudi women who diagnosed to have primary hyperparathyrodism due to single parathyroid adenoma as confirmed biochemically and radiologically. At operation, the adenoma was found to be an intrathyroid and therefore a thyroid lobectomy was performed. Histology of the excised lobe revealed in addition to the intrathyroid parathyroid adenoma a concurrent occult thyroid papillary carcinoma. The interesting association is discussed based on a literature review. (author)

  5. MR imaging of occult fractures of the knee

    International Nuclear Information System (INIS)

    Mink, J.H.; Deutsch, A.L.

    1988-01-01

    The authors encountered 65 radiographically occult fractures that they classified into five types. Bone bruises were a result of direct trauma or were associated with ligamentous injury. They were characterized by geographic foci of decreased signal on short repetition time (TR), short echo time (TE) sequences. Stress fractures were linear or globular foci of low signal on short TR, short TE sequences. Osteochondral fractures were displaced or impacted types; the latter were often associated with an anterior cruciate ligament tear. Tibial fractures were minimally displaced, vertically oriented fractures extending into the plateaus. Femoral fractures were Y-shaped, extending across the supracondylar region

  6. Laser fluorescence bronchoscope for localization of occult lung tumors

    International Nuclear Information System (INIS)

    Profio, A.E.; Doiron, D.R.; King, E.G.

    1979-01-01

    A system for imaging occult bronchogenic carcinoma by the fluorescence of previously-injected, tumor-specific compound hematoporphyrin-derivative has been assembled and successfully used to locate a tumor l mm thick. The violet excitation source is a krypton ion laser coupled to fused quartz fiber light conductor. An electrostatic image intensifier attached to a standard flexible fiberoptic bronchoscope provides a bright image even at relatively low irradiance. A red secondary filter rejects most reflected background and autofluorescence. Sensitivity and contrast capability of the system should permit detection of a tumor less than 0.1 mm thick

  7. Occult microscopic endometriosis: undetectable by laparoscopy in normal peritoneum.

    Science.gov (United States)

    Khan, Khaleque Newaz; Fujishita, Akira; Kitajima, Michio; Hiraki, Koichi; Nakashima, Masahiro; Masuzaki, Hideaki

    2014-03-01

    Is there any occurrence of hidden (occult) endometriotic lesions in normal peritoneum of women with and without visible endometriosis? We detected a slightly higher occurrence of occult microscopic endometriosis (OME) in normal peritoneum of women with visible endometriosis than in control women. Based on a small number of cases, the concept of invisible microscopic endometriosis in visually normal peritoneum has been reported for more than a decade but there is controversy regarding their tissue activity and clinical significance. This case-controlled research study was conducted with prospectively collected normal peritoneal samples from 151 women with and 62 women without visible endometriosis. Normal peritoneal biopsy specimens from different pelvic sites of were collected during laparoscopy. A histological search of all peritoneal biopsy specimens for the detection of invisible endometriosis was done by immunoreaction to Ber-EP4 (epithelial cell marker), CD10 (stromal cell marker) and Calretinin (mesothelial cell marker). Tissue expression of estrogen/progesterone receptors (ER/PR) and cell proliferation marker, Ki-67, was performed by immunohistochemistry to identify tissue activity. Three different patterns of OME were detected based on (I) the presence of typical gland/stroma, (II) reactive hyperplastic change of endometrioid epithelial cells with surrounding stroma and (III) single-layered epithelium-lined cystic lesions with surrounding stroma. A higher tendency toward the occurrence of OME was found in women with visible endometriosis (15.2%, 23/151) compared with control women (6.4%, 4/62) (P = 0.06, χ(2) test). The epithelial cells and/or stromal cells of OME lesions were immunoreactive to Ber-EP4 and CD10 but not reactive to Calretinin. ER and PR expression was observed in all patterns of OME lesions. Ki-67 index was significantly higher in pattern I/II OME lesions than in pattern III OME lesions (Pendometriosis due to the presence of adhesions in

  8. Significance of mammographic signs in clinically occult disease

    Energy Technology Data Exchange (ETDEWEB)

    Waal, J.C. de; Steil, B.; Baltzer, J.; Vaillant, W.; Zander, J.

    1987-10-01

    The significance of various radiographic signs in 183 patients with clinically occult breast disease is described. 30.6% hat a carcinoma of the breast or a carcinoma in situ. The radiological features have varying predictive values and there is variation in the incidence of lymph node metastases. It is considered useful to classify the radiological appearances under the headings of round foci, star-shaped opacities, diffuse opacities, opacities with calcification and groups of micro-calcification. Despite the early diagnosis, 24% of patients already had lymph node metastases.

  9. Occult lung malignancy presenting with finger pain: a case report

    Directory of Open Access Journals (Sweden)

    Embley Matthew A

    2008-12-01

    Full Text Available Abstract Introduction Lung cancer is currently one of the most common malignancies in the world. Early detection is an important prognostic factor. Unfortunately, initial symptoms may be vague and a substantial proportion of cases present with the effects of metastases. Case presentation We discuss a case of occult lung malignancy in a 61-year-old man. The only symptom at presentation was pain in the right ring finger due to metastasis from the lung primary. Conclusion This case highlights the need for vigilance when a patient presents with unusual or unexplained symptoms, especially if they have known risk factors for cancer.

  10. On-Demand Urine Analyzer

    Science.gov (United States)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  11. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    Science.gov (United States)

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  12. Determination of americium in urine

    International Nuclear Information System (INIS)

    Shvydko, N.S.; Mikhajlova, O.A.; Popov, D.K.

    1988-01-01

    A technique has been developed for the determination of americium 241 in urine by a raiochemical purification of the nuclide from uranium (upon co-precipitation of americium 241 with calcium and lanthanum), plutonium, thorum, and polonium 210 (upon co-precipitation of these radionuclides with zirconium iodate). α-Radioactivity was measured either in a thick layer of the americium 241 precipitate with a nonisotope carrier or in thin-layer preparations after electrolytic precipitation of americium 241 on a cathode

  13. James Webb Space Telescope Observations of Stellar Occultations by Solar System Bodies and Rings

    Science.gov (United States)

    Santos-Sanz, P.; French, R. G.; Pinilla-Alonso, N.; Stansberry, J.; Lin, Z-Y.; Zhang, Z-W.; Vilenius, E.; Mueller, Th.; Ortiz, J. L.; Braga-Ribas, F.; hide

    2016-01-01

    In this paper, we investigate the opportunities provided by the James Webb Space Telescope (JWST) for significant scientific advances in the study of Solar System bodies and rings using stellar occultations. The strengths and weaknesses of the stellar occultation technique are evaluated in light of JWST's unique capabilities. We identify several possible JWST occultation events by minor bodies and rings and evaluate their potential scientific value. These predictions depend critically on accurate a priori knowledge of the orbit of JWST near the Sun–Earth Lagrange point 2 (L2). We also explore the possibility of serendipitous stellar occultations by very small minor bodies as a byproduct of other JWST observing programs. Finally, to optimize the potential scientific return of stellar occultation observations, we identify several characteristics of JWST's orbit and instrumentation that should be taken into account during JWST's development.

  14. Wave propagation simulation of radio occultations based on ECMWF refractivity profiles

    DEFF Research Database (Denmark)

    von Benzon, Hans-Henrik; Høeg, Per

    2015-01-01

    This paper describes a complete radio occultation simulation environment, including realistic refractivity profiles, wave propagation modeling, instrument modeling, and bending angle retrieval. The wave propagator is used to simulate radio occultation measurements. The radio waves are propagated...... of radio occultations. The output from the wave propagator simulator is used as input to a Full Spectrum Inversion retrieval module which calculates geophysical parameters. These parameters can be compared to the ECMWF atmospheric profiles. The comparison can be used to reveal system errors and get...... a better understanding of the physics. The wave propagation simulations will in this paper also be compared to real measurements. These radio occultations have been exposed to the same atmospheric conditions as the radio occultations simulated by the wave propagator. This comparison reveals that precise...

  15. The performance of fully automated urine analysis results for predicting the need of urine culture test

    Directory of Open Access Journals (Sweden)

    Hatice Yüksel

    2014-06-01

    Full Text Available Objectives: Urinalysis and urine culture are most common tests for diagnosis of urinary tract infections. The aim of our study is to examine the diagnostic performance of urine analysis and the role of urine analysis to determine the requirements for urine culture. Methods: Urine culture and urine analysis results of 362 patients were retrospectively analyzed. Culture results were taken as a reference for chemical and microscopic examination of urine and diagnostic accuracy of the test parameters, that may be a marker for urinary tract infection, and the performance of urine analysis were calculated for predicting the urine culture requirements. Results: A total of 362 urine culture results of patients were evaluated and 67% of them were negative. The results of leukocyte esterase and nitrite in chemical analysis and leukocytes and bacteria in microscopic analysis were normal in 50.4% of culture negative urines. In diagnostic accuracy calculations, leukocyte esterase (86.1% and microscopy leukocytes (88.0% were found with high sensitivity, nitrite (95.4% and bacteria (86.6% were found with high specificity. The area under the curve was calculated as 0.852 in ROC analysis for microscopic examination for leukocytes. Conclusion: Full-automatic urine devices can provide sufficient diagnostic accuracy for urine analysis. The evaluation of urine analysis results in an effective way can predict the necessity for urine culture requests and especially may contribute to a reduction in the work load and cost. J Clin Exp Invest 2014; 5 (2: 286-289

  16. Antibiotic prescribing practices for catheter urine culture results.

    Science.gov (United States)

    Chiu, Jonathan; Thompson, G William; Austin, Thomas W; Hussain, Zafar; John, Michael; Bombassaro, Anne Marie; Connelly, Sarah E; Elsayed, Sameer

    2013-01-01

    The literature suggests that positive results of catheter urine cultures frequently lead to unnecessary antimicrobial prescribing, which therefore represents an important target for stewardship. To assess the appropriateness of antibiotic prescribing in response to the results of urine cultures from patients with indwelling urinary catheters. This retrospective study was conducted at a tertiary care centre and involved adults with indwelling urinary catheters from whom urine specimens were obtained for culture. Patients with positive or negative culture results were identified from microbiology laboratory reports. The medical records of consecutive patients were screened to select a sample of 80 inpatients (40 per group). Abstracted patient histories were independently evaluated by an expert panel of 3 infectious diseases consultants blinded to the decisions of prescribers and of fellow panelists. The primary end point was concordance of each patient's treatment decision (with respect to the indication) between the expert panel (based on majority agreement, i.e., at least 2 of the 3 expert panelists) and the prescriber. The secondary end points were unnecessary days of therapy and selected outcomes over a predefined period after urine was obtained for culture. A total of 591 charts were screened to generate the targeted number of patients. Baseline demographic characteristics were comparable for the 2 groups, except antibiotic exposure before urine collection was significantly more frequent for the group with negative culture results. The treatment decision was concordant in 40% (16/40) of the patients with a positive culture result and 85% (34/40) of those with a negative culture result (p < 0.001). The most common reason for discordance was administration of antibiotics when not indicated (23 of 24 patients with a positive result and 5 of 6 patients with a negative result), which accounted for 165 and 32 unnecessary days of therapy per 1000 inpatient

  17. PREVALENCE OF OCCULT DEPRESSION IN ELDERLY WITH CHRONIC CO - MORBIDS

    Directory of Open Access Journals (Sweden)

    Sachin

    2015-02-01

    Full Text Available BACKGROUND: Growth in elderly population has led to an increase in age related diseases and mainly depression which is affecting the quality of life. Depression is more prevalent amongst elderly individuals with medical illnesses and emerging public health problem leading to increased morbidity and disability worldwide. AIMS AND OBJE CTIVES: To assess the prevalence of occult depression in elderly patients with chronic co - morbid medical conditions. MATERIALS AND METHODS: It was a cross - sectional study conducted in tertiary hospital. Total 100 elderly patients with underlying chronic me dical illnesses were included. Depression in study population was assessed by geriatric depression scale and analyzed. RESULT: Out of 100 patients 23(23% had depression. Females 12/39(30.76% were affected more than males 11/61 (18.03%. Depression was mo re prevalent among patients with 3 or more co - morbid conditions (45.4% as compared to <3 (11.9%. CONCLUSION: Elderly patients with multiple chronic medical illnesses may have associated occult depression. Screening of these patients for depression couple d with appropriate psychiatric referral should be an integral part of Geriatric service

  18. Fluctuations of radio occultation signals in sounding the Earth's atmosphere

    Directory of Open Access Journals (Sweden)

    V. Kan

    2018-02-01

    Full Text Available We discuss the relationships that link the observed fluctuation spectra of the amplitude and phase of signals used for the radio occultation sounding of the Earth's atmosphere, with the spectra of atmospheric inhomogeneities. Our analysis employs the approximation of the phase screen and of weak fluctuations. We make our estimates for the following characteristic inhomogeneity types: (1 the isotropic Kolmogorov turbulence and (2 the anisotropic saturated internal gravity waves. We obtain the expressions for the variances of the amplitude and phase fluctuations of radio occultation signals as well as their estimates for the typical parameters of inhomogeneity models. From the GPS/MET observations, we evaluate the spectra of the amplitude and phase fluctuations in the altitude interval from 4 to 25 km in the middle and polar latitudes. As indicated by theoretical and experimental estimates, the main contribution into the radio signal fluctuations comes from the internal gravity waves. The influence of the Kolmogorov turbulence is negligible. We derive simple relationships that link the parameters of internal gravity waves and the statistical characteristics of the radio signal fluctuations. These results may serve as the basis for the global monitoring of the wave activity in the stratosphere and upper troposphere.

  19. Progress in turbulence detection via GNSS occultation data

    Directory of Open Access Journals (Sweden)

    L. B. Cornman

    2012-04-01

    Full Text Available The increased availability of radio occultation (RO data offers the ability to detect and study turbulence in the Earth's atmosphere. An analysis of how RO data can be used to determine the strength and location of turbulent regions is presented. This includes the derivation of a model for the power spectrum of the log-amplitude and phase fluctuations of the permittivity (or index of refraction field. The bulk of the paper is then concerned with the estimation of the model parameters. Parameter estimators are introduced and some of their statistical properties are studied. These estimators are then applied to simulated log-amplitude RO signals. This includes the analysis of global statistics derived from a large number of realizations, as well as case studies that illustrate various specific aspects of the problem. Improvements to the basic estimation methods are discussed, and their beneficial properties are illustrated. The estimation techniques are then applied to real occultation data. Only two cases are presented, but they illustrate some of the salient features inherent in real data.

  20. Image guidance improves localization of sonographically occult colorectal liver metastases

    Science.gov (United States)

    Leung, Universe; Simpson, Amber L.; Adams, Lauryn B.; Jarnagin, William R.; Miga, Michael I.; Kingham, T. Peter

    2015-03-01

    Assessing the therapeutic benefit of surgical navigation systems is a challenging problem in image-guided surgery. The exact clinical indications for patients that may benefit from these systems is not always clear, particularly for abdominal surgery where image-guidance systems have failed to take hold in the same way as orthopedic and neurosurgical applications. We report interim analysis of a prospective clinical trial for localizing small colorectal liver metastases using the Explorer system (Path Finder Technologies, Nashville, TN). Colorectal liver metastases are small lesions that can be difficult to identify with conventional intraoperative ultrasound due to echogeneity changes in the liver as a result of chemotherapy and other preoperative treatments. Interim analysis with eighteen patients shows that 9 of 15 (60%) of these occult lesions could be detected with image guidance. Image guidance changed intraoperative management in 3 (17%) cases. These results suggest that image guidance is a promising tool for localization of small occult liver metastases and that the indications for image-guided surgery are expanding.

  1. 'Trick', 'manipulation' and 'farce': Albert Moll's critique of occultism.

    Science.gov (United States)

    Wolffram, Heather

    2012-04-01

    In July 1925, the psychiatrist Albert Moll appeared before the district court in Berlin-Schöneberg charged with having defamed the medium Maria Vollhardt (alias Rudloff) in his 1924 book Der Spiritismus [Spiritism]. Supported by some of Berlin's most prominent occultists, the plaintiff--the medium's husband--argued that Moll's use of terms such as 'trick', 'manipulation' and 'farce' in reference to Vollhardt's phenomena had been libellous. In the three-part trial that followed, however, Moll's putative affront to the medium--of which he was eventually acquitted--was overshadowed, on the one hand, by a debate over the scientific status of parapsychology, and on the other, by the question of who--parapsychologists, occultists, psychiatrists or jurists--was entitled to claim epistemic authority over the occult. This paper will use the Rudloff-Moll trial as a means of examining Moll's critique of occultism, not only as it stood in the mid-1920s, but also as it had developed since the 1880s. It will also provide insight into the views of Germany's occultists and parapsychologists, who argued that their legitimate bid for scientific credibility was hindered by Dunkelmänner [obscurantists] such as Albert Moll.

  2. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    Science.gov (United States)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

  3. Ex Luna Scientia: The Lunar Occultation Explorer (LOX)

    Science.gov (United States)

    Miller, Richard

    2017-01-01

    The Lunar Occultation Explorer (LOX) is a next-generation mission concept that provides new capabilities for time-domain astrophysics and established the Moon as a platform for nuclear astrophysics. Performance requirements are driven by Type-Ia supernova (SNeIa) science goals that seek to revel details of these profoundly radioactive objects, including their diversity. Primary science objectives include, but are not limited to, probing the fundamental thermonuclear physics processes, performing a census of progenitors and their explosion mechanisms, and evaluating the environmental conditions and intrinsic systematics of these enigmatic objects. LOX provides new capabilities for all-sky, continuous monitoring in the MeV regime (0.1-10 MeV) by leveraging the Lunar Occultation Technique (LOT). Key benefits of the LOX/LOT approach include maximizing the ratio of sensitive-to-total deployed mass, low implementation risk, and demonstrated operational simplicity that leverages extensive experience with planetary orbital geochemistry investigations; LOX also enables long-term monitoring of MeV gamma-ray sources, a critical capability for SNeIa science. Proof-of-principle efforts validated all aspects of the mission using previously deployed lunar science assets, and led to the first high-energy gamma-ray source detected at the Moon. LOX mission performance, development progress, and expectations for science investigations will be presented.

  4. The ionosphere of Europa from Galileo radio occultations

    Science.gov (United States)

    Kliore, A. J.; Hinson, D. P.; Flasar, F. M.; Nagy, A. F.; Cravens, T. E.

    1997-01-01

    The Galileo spacecraft performed six radio occultation observations of Jupiter's Galilean satellite Europa during its tour of the jovian system. In five of the six instances, these occultations revealed the presence of a tenuous ionosphere on Europa, with an average maximum electron density of nearly 10(4) per cubic centimeter near the surface and a plasma scale height of about 240 +/- 40 kilometers from the surface to 300 kilometers and of 440 +/- 60 kilometers above 300 kilometers. Such an ionosphere could be produced by solar photoionization and jovian magnetospheric particle impact in an atmosphere having a surface density of about 10(8) electrons per cubic centimeter. If this atmosphere is composed primarily of O2, then the principal ion is O2+ and the neutral atmosphere temperature implied by the 240-kilometer scale height is about 600 kelvin. If it is composed of H2O, the principal ion is H3O+ and the neutral temperature is about 340 kelvin. In either case, these temperatures are much higher than those observed on Europa's surface, and an external heating source from the jovian magnetosphere is required.

  5. Waves in the Martian Atmosphere: Results from MGS Radio Occultations

    Science.gov (United States)

    Flasar, F. M.; Hinson, D. P.; Tyler, G. L.

    1999-01-01

    Temperatures retrieved from Mars Global Surveyor radio occultations have been searched for evidence of waves. Emphasis has been on the initial series of occultations between 29 deg N and 64 deg S, obtained during the early martian southern summer, L(sub s) = 264 deg - 308 deg. The profiles exhibit an undulatory behavior that is suggestive of vertically propagating waves. wavelengths approximately 10 km are often dominant, but structure on smaller scales is evident. The undulatory structure is most pronounced between latitudes 29 deg N and 10 deg S, usually in regions of "interesting" topography, e.g., in the Tharsis region and near the edge of Syrtis Major. Several temperature profiles, particularly within 30 deg of the equator, exhibit lapse rates that locally become superadiabatic near the 0.4-mbar level or at higher altitudes. This implies that the waves are "breaking" and depositing horizontal momentum into the atmosphere. Such a deposition may play an important role in modulating the atmospheric winds, and characterizing the spatial and temporal distribution of these momentum transfers can provide important clues to understanding how the global circulation is maintained.

  6. The floating cardiac fat pad-sign of occult pneumothorax.

    Science.gov (United States)

    Kaufman, Claire; Bokhari, S A Jamal

    2016-08-01

    Pneumothoraces are a possible sequela of chest trauma with potential morbidity and mortality if not recognized and treated promptly. A portable supine chest radiograph is frequently the first radiologic study performed in the setting of trauma. While large pneumothoraces can be readily recognized on these radiographs, smaller pneumothoraces are missed in up to 15 % of trauma patients. There are many radiographic signs of occult pneumothoraces, and we are presenting a new radiographic sign of occult pneumothorax. The floating cardiac fat pad sign occurs when pleural air collects anteriorly and superiorly in the most non-dependent portion of the chest lifting the pericardial fat pad off the diaphragm. Lung markings are still seen surrounding the pericardial fat pad due to the inflated lower lobe of the lung resting dependently. Rapid and accurate identification of pneumothoraces is critical but often difficult on chest radiographs. Although there are many existing radiographic signs for identification of pneumothorax, prospective identification of small pneumothoraces is still relatively poor. Here, we describe an additional sign which aides in the detection of pneumothoraces, the floating cardiac fat pad. When present, this should prompt further evaluation with chest CT or upright chest radiograph.

  7. Human Papillomavirus Detection from Human Immunodeficiency Virus-Infected Colombian Women's Paired Urine and Cervical Samples

    Science.gov (United States)

    Munoz, Marina; Camargo, Milena; Soto-De Leon, Sara C.; Sanchez, Ricardo; Parra, Diana; Pineda, Andrea C.; Sussmann, Otto; Perez-Prados, Antonio; Patarroyo, Manuel E.; Patarroyo, Manuel A.

    2013-01-01

    Infection, coinfection and type-specific human papillomavirus (HPV) distribution was evaluated in human immunodeficiency virus (HIV)-positive women from paired cervical and urine samples. Paired cervical and urine samples (n = 204) were taken from HIV-positive women for identifying HPV-DNA presence by using polymerase chain reaction (PCR) with three generic primer sets (GP5+/6+, MY09/11 and pU1M/2R). HPV-positive samples were typed for six high-risk HPV (HR-HPV) (HPV-16, -18, -31, -33, -45 and -58) and two low-risk (LR-HPV) (HPV-6/11) types. Agreement between paired sample results and diagnostic performance was evaluated. HPV infection prevalence was 70.6% in cervical and 63.2% in urine samples. HPV-16 was the most prevalent HPV type in both types of sample (66.7% in cervical samples and 62.0% in urine) followed by HPV-31(47.2%) in cervical samples and HPV-58 (35.7%) in urine samples. There was 55.4% coinfection (infection by more than one type of HPV) in cervical samples and 40.2% in urine samples. Abnormal Papanicolau smears were observed in 25.3% of the women, presenting significant association with HPV-DNA being identified in urine samples. There was poor agreement of cervical and urine sample results in generic and type-specific detection of HPV. Urine samples provided the best diagnosis when taking cytological findings as reference. In conclusion including urine samples could be a good strategy for ensuring adherence to screening programs aimed at reducing the impact of cervical cancer, since this sample is easy to obtain and showed good diagnostic performance. PMID:23418581

  8. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples

  9. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low

  10. Breast conservation in the setting of contemporary multimodality treatment provides excellent outcomes for patients with occult primary breast cancer.

    Science.gov (United States)

    Rueth, Natasha M; Black, Dalliah M; Limmer, Angela R; Gabriel, Emmanuel; Huo, Lei; Fornage, Bruno D; Dogan, Basak E; Chavez-MacGregor, Mariana; Yi, Min; Hunt, Kelly K; Strom, Eric A

    2015-01-01

    To evaluate recurrence and survival for patients with occult (T0N+) breast cancer who underwent contemporary treatment, assessing outcomes for breast conservation and mastectomy. We performed a single-institution review of women with occult breast cancer presenting with axillary metastasis without identifiable breast tumor or distant metastasis. We excluded patients with tumors in the axillary tail or mastectomy specimen, patients with additional nonbreast cancer diagnoses, and patients with a history of breast cancer. Breast conservation was defined as axillary node dissection with radiation therapy, without breast surgery. We evaluated patient, tumor, treatment, and outcome variables. Patients were assessed for local, regional, and distant recurrences. Overall survival was calculated using the Kaplan-Meier method. Thirty-six patients met criteria for occult breast cancer. Most of these patients (77.8 %) had N1 disease. Fifty percent of cancers (n = 18) were estrogen receptor-positive; 12 (33.3 %) were triple-negative. All patients were evaluated with mammography. Thirty-five patients had breast ultrasound (97.2 %) and 33 (91.7 %) had an MRI. Thirty-four patients (94.4 %) were treated with chemotherapy and 33 (91.7 %) with radiotherapy. Twenty-seven patients (75.0 %) were treated with breast conservation. The median follow-up was 64 months. There were no local or regional failures. One distant recurrence occurred >5 years after diagnosis, resulting in a 5-years overall survival rate of 100 %. There were no significant survival differences between patients receiving breast conservation versus mastectomy (p = 0.7). Breast conservation-performed with contemporary imaging and multimodality treatment-provides excellent local control and survival for women with T0N+ breast cancer and can be safely offered instead of mastectomy.

  11. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  12. Letter to the EditorAbel transform inversion of radio occultation measurements made with a receiver inside the Earth’s atmosphere

    Directory of Open Access Journals (Sweden)

    S. B. Healy

    2002-08-01

    Full Text Available Radio occultation measurements made with a receiver inside the Earth’s atmosphere can be inverted, assuming local spherical symmetry, with an Abel transform to provide an estimate of the atmospheric refractive index profile. The measurement geometry is closely related to problems encountered when inverting seismic time-travel data and solar occultation measurements, where the Abel solution is well known. The method requires measuring both rays that originate from above and below the local horizon of the receiver. The Abel transform operates on a profile of "partial bending angles" found by subtracting the positive elevation measurement from the negative elevation value with the same impact parameter. In principle, the refractive index profile can be derived from measurements with a single frequency GPS receiver because the ionospheric bending is removed when the partial bending angle is evaluated.Key words. Atmospheric composition and structure (pressure, density and temperature – Radio science (remote sensing

  13. Letter to the EditorAbel transform inversion of radio occultation measurements made with a receiver inside the Earth’s atmosphere

    Directory of Open Access Journals (Sweden)

    J. Haase

    Full Text Available Radio occultation measurements made with a receiver inside the Earth’s atmosphere can be inverted, assuming local spherical symmetry, with an Abel transform to provide an estimate of the atmospheric refractive index profile. The measurement geometry is closely related to problems encountered when inverting seismic time-travel data and solar occultation measurements, where the Abel solution is well known. The method requires measuring both rays that originate from above and below the local horizon of the receiver. The Abel transform operates on a profile of "partial bending angles" found by subtracting the positive elevation measurement from the negative elevation value with the same impact parameter. In principle, the refractive index profile can be derived from measurements with a single frequency GPS receiver because the ionospheric bending is removed when the partial bending angle is evaluated.Key words. Atmospheric composition and structure (pressure, density and temperature – Radio science (remote sensing

  14. Prediction of occult lymph node metastasis in squamous cell carcinoma of the oral cavity and the oropharynx using peritumoral Prospero homeobox protein 1 lymphatic nuclear quantification.

    Science.gov (United States)

    Mermod, Maxime; Bongiovanni, Massimo; Petrova, Tatiana V; Dubikovskaya, Elena A; Simon, Christian; Tolstonog, Genrich; Monnier, Yan

    2016-09-01

    The use of lymphatic vessel density as a predictor of occult lymph node metastasis (OLNM) in head and neck squamous cell carcinoma (HNSCC) has never been reported. Staining of the specific lymphatic endothelial cells nuclear marker, PROX1, as an indicator of lymphatic vessel density was determined by counting the number of positive cells in squamous cell carcinomas (SCCs) of the oral cavity and the oropharynx with clinically negative necks. Correlation with histopathological data was established. Peritumoral PROX1 lymphatic nuclear count significantly correlated with the detection of OLNM in multivariate analysis (p oral cavity and the oropharynx allows accurate prediction of occult lymph node metastasis. © 2016 Wiley Periodicals, Inc. Head Neck 38: 1407-1415, 2016. © 2016 Wiley Periodicals, Inc.

  15. Initial Experience of Tomosynthesis-Guided Vacuum-Assisted Biopsies of Tomosynthesis-Detected (2D Mammography and Ultrasound Occult) Architectural Distortions.

    Science.gov (United States)

    Patel, Bhavika K; Covington, Matthew; Pizzitola, Victor J; Lorans, Roxanne; Giurescu, Marina; Eversman, William; Lewin, John

    2018-03-23

    As experience and aptitude in digital breast tomosynthesis (DBT) have increased, radiologists are seeing more areas of architectural distortion (AD) on DBT images compared with standard 2D mammograms. The purpose of this study is to report our experience using tomosynthesis-guided vacuum-assisted biopsies (VABs) for ADs that were occult at 2D mammography and ultrasound and to analyze the positive predictive value for malignancy. We performed a retrospective review of 34 DBT-detected ADs that were occult at mammography and ultrasound. We found a positive predictive value of 26% (nine malignancies in 34 lesions). Eight of the malignancies were invasive and one was ductal carcinoma in situ. The invasive cancers were grade 1 (4/8; 50%), grade 2 (2/8; 25%), or grade 3 (1/8; 13%); information about one invasive cancer was not available. The mean size of the invasive cancers at pathologic examination was 7.5 mm (range, 6-30 mm). Tomosynthesis-guided VAB is a feasible method to sample ADs that are occult at 2D mammography and ultrasound. Tomosynthesis-guided VAB is a minimally invasive method that detected a significant number of carcinomas, most of which were grade 1 cancers. Further studies are needed.

  16. Significance of serum and urine β2-MG abnormality for diabetes

    International Nuclear Information System (INIS)

    Yu Fengling; Zhang Qiliang; Feng Zhixu; Hou Xiangzhen

    1995-01-01

    Levels of serum and urine β 2 -MG are determined in 114 patients with diabetes. It is found that levels of serum and urine β 2 -MG in diabetes are significantly higher than that of normal contrasts (P 2 -MG are increased with diabetes progress, especially urine β 2 -MG. There is no difference in levels of serum and urine β 2 -MG between non-insulin dependent diabetes mellitus (NIDDM) and insulin dependent diabetes mellitus (IDDM, P>0.05). Urine β 2 -MG levels of diabetes are relatively increased with the increase of serum β 2 -MG levels. Both are obviously positive correlation. While diabetes progressing, both are gradually increased. It can be shown that the longer diabetes process, the more renal function was damaged. Therefore, determination of β 2 -MG is very important for early diagnosing, preventing and treating diabetic nephropathy

  17. Analysis of urobilinogen and urine bilirubin for intra-abdominal injury in blunt trauma patients.

    Science.gov (United States)

    Gorchynski, Julie; Dean, Kevin; Anderson, Craig L

    2009-05-01

    To determine the point prevalence of urine bilirubin, urine hemoglobin and urobilinogen in blunt trauma patients, and to evaluate its utility as a screening tool for intra-abdominal injury. Data analysis of 986 consecutive trauma patients of which 698 were adult blunt trauma patients. Five-hundred sixteen subjects had a urinalysis and a CT scan of the abdomen/pelvis or exploratory laparotomy. We reviewed initial urinalysis results from trauma patients in the emergency department (ED) for the presence of urine hemoglobin, uroblinogen and urine bilirubin. Computed tomography (CT) scan results and operative reports were reviewed from the trauma registry for evidence of liver laceration, spleen laceration, bowel or mesenteric injuries. There were 73 injuries and 57/516 patients (11%) with intra-abdominal injury. Urinalysis was positive for urobilinogen in 28/516 (5.4%) patients, urine bilirubin in 15/516 (2.9%) patients and urine hemoglobin in 313/516 (61%) patients. Nineteen/forty-seven (4%) subjects had liver lacerations, 28/56 (5%) splenic lacerations, and 15/5 (3%) bowel or mesenteric injury. Comparing the proportion of patients that had urobilinogen detected in the group with and without intra-abdominal injury, 8/28 (29%) subjects with urobilinogen, 5/15 (33%) subjects with bilirubin and 47/313 (15%) subjects with urine hemoglobin were found to have liver lacerations, spleen lacerations, or bowel/mesenteric injuries. Preexisting liver or biliary conditions were not statistically associated with elevation of urine bilirubin, urine hemoglobin or urobilinogen on initial urinalysis after blunt abdominal trauma. Point prevalence for urobilinogen, urine bilirubin and urine hemoglobin are 5.43% (28/516), 2.91% (15/516) and 60.7% (313/516) respectively. The utility of the initial routine urinalysis in the ED for adult blunt abdominal trauma patients should not be used as a screening tool for the evaluation of intra-abdominal injury.

  18. Diffraction-based analysis of tunnel size for a scaled external occulter testbed

    Science.gov (United States)

    Sirbu, Dan; Kasdin, N. Jeremy; Vanderbei, Robert J.

    2016-07-01

    For performance verification of an external occulter mask (also called a starshade), scaled testbeds have been developed to measure the suppression of the occulter shadow in the pupil plane and contrast in the image plane. For occulter experiments the scaling is typically performed by maintaining an equivalent Fresnel number. The original Princeton occulter testbed was oversized with respect to both input beam and shadow propagation to limit any diffraction effects due to finite testbed enclosure edges; however, to operate at realistic space-mission equivalent Fresnel numbers an extended testbed is currently under construction. With the longer propagation distances involved, diffraction effects due to the edge of the tunnel must now be considered in the experiment design. Here, we present a diffraction-based model of two separate tunnel effects. First, we consider the effect of tunnel-edge induced diffraction ringing upstream from the occulter mask. Second, we consider the diffraction effect due to clipping of the output shadow by the tunnel downstream from the occulter mask. These calculations are performed for a representative point design relevant to the new Princeton occulter experiment, but we also present an analytical relation that can be used for other propagation distances.

  19. Green Urine in Traditional Persian Medicine

    Science.gov (United States)

    Kolouri, Sepideh; Daneshfard, Babak; Jaladat, Amir-Mohammad; Tafazoli, Vahid

    2016-01-01

    The color of urine is an important factor in urine examination, which can help physicians differentiate various diseases. Today, it is known that certain dyes, drug intoxications, and diseases can induce green urine discoloration. In the view of traditional Persian medicine, which is based on humoral medicine, green urine discoloration is generally referred to the dominance of coldness in the body. In fact, it is considered to be a result of a special kind of humoral imbalance and fluid depletion or retention in the human body. Persian scholars believed that green urine could be an indicator of intoxication or a predictor of an imminent spasm or convulsion in pediatric patients. Further investigations could result in finding new diagnostic scales of urine color based on the teachings of traditional Persian medicine. PMID:27103627

  20. Performance of Copan WASP for Routine Urine Microbiology

    Science.gov (United States)

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  1. Role of Urine Drug Testing in the Current Opioid Epidemic.

    Science.gov (United States)

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  2. The Consequence of Delayed Fixation on Subsequent Preservation of Urine Cells

    Directory of Open Access Journals (Sweden)

    Hussain G. Ahmed,

    2011-01-01

    Full Text Available Objectives: Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory.Methods: Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95�0ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, atp=0.05.Results: The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001.Conclusion: Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  3. Occult Hepatitis B Virus infection in ART-Naive HIV-Infected Patients seen at a Tertiary Care Centre in North India

    Directory of Open Access Journals (Sweden)

    Singh Sarman

    2010-03-01

    Full Text Available Abstract Background Co-infections of hepatitis B and C viruses are frequent with HIV due to shared routes of transmission. In most of the tertiary care health settings, HIV reactive patients are routinely tested for HBsAg and anti-HCV antibodies to rule out these co-infections. However, using the routine serological markers one can only detect active HBV infection while the occult HBV infection may be missed. There is insufficient data from India on HIV-HBV co-infection and even scarce on occult HBV infection in this group. Methods We estimated the burden of HBV infection in patients who were tested positive for HIV at a tertiary care centre in north India. We also attempted to determine the prevalence and clinical characteristics of occult HBV infection among these treatment-naïve patients and compare their demographic features with other HIV patients. During a period of 6 years between January 2002 to December 2007, 837 HIV positive patients (631 males and 206 females (M: F :: 3.06:1 were tested for serological markers of HBV (HBsAg and HCV (anti-HCV antibodies infections in our laboratory. For comparison 1000 apparently healthy, HIV-negative organ donors were also included in the study. Data on demographics, sexual behaviour, medical history, laboratory tests including the serum ALT and CD4 count of these patients were recorded. A sub-group of 53 HBsAg negative samples from HIV positive patients were assessed for anti-HBs, anti-HBc total (IgG+IgM and HBV-DNA using a highly sensitive qualitative PCR and analysed retrospectively. Results Overall, 7.28% of HIV positive patients showed presence of HBsAg as compared to 1.4% in the HIV negative control group. The prevalence of HBsAg was higher (8.55% in males than females (3.39%. The study revealed that occult HBV infection with detectable HBV-DNA was prevalent in 24.5% of patients positive for anti-HBc antibodies; being 45.5% in HBsAg negative patients. Most importantly the occult infection was

  4. Urine Bag as a Modern Day Matula

    OpenAIRE

    Viswanathan, Stalin

    2013-01-01

    Since time immemorial uroscopic analysis has been a staple of diagnostic medicine. It received prominence during the middle ages with the introduction of the matula. Urinary discoloration is generally due to changes in urochrome concentration associated with the presence of other endogenous or exogenous pigments. Observation of urine colors has received less attention due to the advances made in urinalysis. A gamut of urine colors can be seen in urine bags of hospitalized patients that may gi...

  5. Radioimmunoassay of triiodothyronine in urine

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gembicki, M.; Schneider, E.; Eder, M.

    1977-01-01

    In 21 cases of hypothyroidism, in 39 cases of hyperthyroidism, in 54 healthy subjects, in 23 pregnant women, and in certain internal diseases determinations of triiodothyronine were carried out in urine by radioimmunoassay. Anti-T 3 antibodies were obtained in rabbits and sheep immunized with a complex of bovine albumin with triiodothyronine ester. Labelled triiodothyronine of high specific activity was obtained by iodinating triodothyronine by the chloramine method. Determinations of triiodothyronine were performed in morning urine and the obtained values were calculated for one-hour excretion. In healthy subjects the excretion of T 3 was from 20 to 95 ng/hour, in hyperthyroidism it was significantly raised to from 120 to over 600 ng/hour, while in most cases of hypothyroidism it was decreased. In pregnancy the urinary excretion of T 3 was normal amounting to from 34 to 87 ng/hour, although in most cases the serum T 3 concentration was raised. In cases of anorexia nervosa and in obese starving subjects the excretion of T 3 fell significantly, and similarly low excretion was found in some cases of debilitating diseases and myocardial infarction. (author)

  6. First light of an external occulter testbed at flight Fresnel numbers

    Science.gov (United States)

    Kim, Yunjong; Sirbu, Dan; Hu, Mia; Kasdin, Jeremy; Vanderbei, Robert J.; Harness, Anthony; Shaklan, Stuart

    2017-01-01

    Many approaches have been suggested over the last couple of decades for imaging Earth-like planets. One of the main candidates for creating high-contrast for future Earth-like planets detection is an external occulter. The external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. The occulter is typically tens of meters in diameter and the separation from the telescope is of the order of tens of thousands of kilometers. Optical testing of a full-scale external occulter on the ground is impossible because of the long separations. Therefore, laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we have designed and built a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. The goal of this experiment is to demonstrate a pupil plane suppression of better than 1e-9 with a corresponding image plane contrast of better than 1e-11. The occulter testbed uses a 77.2 m optical propagation distance to realize the flight Fresnel number of 14.5. The scaled mask is placed at 27.2 m from the artificial source and the camera is located 50.0 m from the scaled mask. We will use an etched silicon mask, manufactured by the Microdevices Lab(MDL) of the Jet Propulsion Laboratory(JPL), as the occulter. Based on conversations with MDL, we expect that 0.5 μm feature size is an achievable resolution in the mask manufacturing process and is therefore likely the indicator of the best possible performance. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. Here, we present first light result of a sample design operating at a flight Fresnel number and the experimental setup of the testbed. We compare the experimental results with simulations

  7. Influence of misalignments on the performance of externally occulted solar coronagraphs. Application to PROBA-3/ASPIICS

    Science.gov (United States)

    Shestov, S. V.; Zhukov, A. N.

    2018-05-01

    Context. The ASPIICS instrument is a novel externally occulted coronagraph that will be launched on board the PROBA-3 mission of the European Space Agency. The external occulter will be placed on one satellite 150 m ahead of the second satellite that will carry an optical instrument. During 6 h out of 19.38 h of orbit, the satellites will fly in a precise (accuracy around a few millimeters) formation, constituting a giant externally occulted coronagraph. The large distance between the external occulter and the primary objective will allow observations of the white-light solar corona starting from extremely low heights 1.1R⊙. Aims: We intend to analyze influence of shifts of the satellites and misalignments of optical elements on the ASPIICS performance in terms of diffracted light. Based on the quantitative influence of misalignments on diffracted light, we provide a recipe for choosing the size of the internal occulter (IO) to achieve a trade-off between the minimal height of observations and sustainability to possible misalignments. Methods: We considered different types of misalignments and analyzed their influence from optical and computational points of view. We implemented a numerical model of the diffracted light and its propagation through the optical system and computed intensities of diffracted light throughout the instrument. Our numerical approach is based on a model from the literature that considered the axisymmetrical case. Here we extend the model to include nonsymmetrical cases and possible misalignments. Results: The numerical computations fully confirm the main properties of the diffracted light that we obtained from semi-analytical consideration. We obtain that relative influences of various misalignments are significantly different. We show that the internal occulter with RIO = 1.694 mm = 1.1R⊙ is large enough to compensate possible misalignments expected to occur in PROBA-3/ASPIICS. Besides that we show that apodizing the edge of the

  8. Acute Zonal Occult Outer Retinopathy with Atypical Findings

    Directory of Open Access Journals (Sweden)

    Dimitrios Karagiannis

    2014-01-01

    Full Text Available Background. To report a case of acute zonal occult outer retinopathy (AZOOR with atypical electrophysiology findings. Case Presentation. A 23-year-old-female presented with visual acuity deterioration in her right eye accompanied by photopsia bilaterally. Corrected distance visual acuity at presentation was 20/50 in the right eye and 20/20 in the left eye. Fundus examination was unremarkable. Visual field (VF testing revealed a large scotoma. Pattern and full-field electroretinograms (PERG and ERG revealed macular involvement associated with generalized retinal dysfunction. Electrooculogram (EOG light rise and the Arden ratio were within normal limits bilaterally. The patient was diagnosed with AZOOR due to clinical findings, visual field defect, and ERG findings. Conclusion. This is a case of AZOOR with characteristic VF defects and clinical symptoms presenting with atypical EOG findings.

  9. Radiosensitive orbital metastasis as presentation of occult colonic adenocarcinoma.

    Science.gov (United States)

    Ludmir, Ethan B; McCall, Shannon J; Czito, Brian G; Palta, Manisha

    2014-09-19

    An 82-year-old man presented with progressive right frontal headaches. The patient's history was significant for benign polyps on surveillance colonoscopy 2 years prior, without high-grade dysplasia or carcinoma. MRI revealed an enhancing lesion arising within the superomedial aspect of the right orbit. Lesion biopsy demonstrated histological appearance and immunophenotype suggestive of colonic adenocarcinoma. Staging positron emission tomography/CT showed visceral metastases and diffuse activity in the posterior rectosigmoid, consistent with metastatic colon cancer. Treatment of the orbital lesion with external beam radiotherapy to 30 Gy resulted in significant palliation of the patient's headaches. The patient expired 2 months following treatment completion due to disease progression. Orbital metastasis as the initial presentation of an occult colorectal primary lesion is exceedingly rare, and occurred in this patient despite surveillance colonoscopy. Radiotherapy remains an efficacious modality for treatment of orbital metastases. 2014 BMJ Publishing Group Ltd.

  10. Lunar occultations for gamma-ray source measurements

    Science.gov (United States)

    Koch, David G.; Hughes, E. B.; Nolan, Patrick L.

    1990-01-01

    The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

  11. Adolescent Occultism and the Philosophy of Things in Three Novels

    Directory of Open Access Journals (Sweden)

    Samuel Finegan

    2015-11-01

    Full Text Available Shirley Jackson’s 1962 We Have Always Lived in the Castle, Iain Banks’s 1984 The Wasp Factory and Sonya Hartnett’s 2009 Butterfly are novels separated not only by decades, but by distance being produced in the United States, Scotland and Australia respectively. Despite this, each of these texts depicts a young adult in a mimetically recognisable world struggling to reconcile their intuitive occultism with that world. The mediation of magic through assemblages of charged objects creates a philosophy of things – modelling in intuitive and narrative terms the essence and nature of objects familiar from the philosophies of Martin Heidegger and Walter Benjamin. As such, the supernaturalism of Iain Banks, Shirley Jackson and Sonya Hartnett’s narratives implicates their readers – breaking the boundaries of fiction to comment on the material world itself, not through analogy or metaphor but through direct modelling of the potential power and worth of things.

  12. Radiographically Occult and Subtle Fractures: A Pictorial Review

    International Nuclear Information System (INIS)

    Jarraya, M.; Hayashi, D.; Roemer, F.W.; Crema, M.D.; Conlin, J.; Marra, M.D.; Guermazi, A.; Roemer, F.W.; Crema, M.D.; Diaz, L.; Conlin, J.; Jomaah, N.

    2013-01-01

    Radiographically occult and subtle fractures are a diagnostic challenge. They may be divided into (1) high energy trauma fracture, (2) fatigue fracture from cyclical and sustained mechanical stress, and (3) insufficiency fracture occurring in weakened bone (e.g., in osteoporosis and post radiotherapy). Independently of the cause, the initial radiographic examination can be negative either because the findings seem normal or are too subtle. Early detection of these fractures is crucial to explain the patients symptoms and prevent further complications. Advanced imaging tools such as computed tomography, magnetic resonance imaging, and scintigraphy are highly valuable in this context. Our aim is to raise the awareness of radiologists and clinicians in these cases by presenting illustrative cases and a discussion of the relevant literature.

  13. The prototype cameras for trans-Neptunian automatic occultation survey

    Science.gov (United States)

    Wang, Shiang-Yu; Ling, Hung-Hsu; Hu, Yen-Sang; Geary, John C.; Chang, Yin-Chang; Chen, Hsin-Yo; Amato, Stephen M.; Huang, Pin-Jie; Pratlong, Jerome; Szentgyorgyi, Andrew; Lehner, Matthew; Norton, Timothy; Jorden, Paul

    2016-08-01

    The Transneptunian Automated Occultation Survey (TAOS II) is a three robotic telescope project to detect the stellar occultation events generated by TransNeptunian Objects (TNOs). TAOS II project aims to monitor about 10000 stars simultaneously at 20Hz to enable statistically significant event rate. The TAOS II camera is designed to cover the 1.7 degrees diameter field of view of the 1.3m telescope with 10 mosaic 4.5k×2k CMOS sensors. The new CMOS sensor (CIS 113) has a back illumination thinned structure and high sensitivity to provide similar performance to that of the back-illumination thinned CCDs. Due to the requirements of high performance and high speed, the development of the new CMOS sensor is still in progress. Before the science arrays are delivered, a prototype camera is developed to help on the commissioning of the robotic telescope system. The prototype camera uses the small format e2v CIS 107 device but with the same dewar and also the similar control electronics as the TAOS II science camera. The sensors, mounted on a single Invar plate, are cooled to the operation temperature of about 200K as the science array by a cryogenic cooler. The Invar plate is connected to the dewar body through a supporting ring with three G10 bipods. The control electronics consists of analog part and a Xilinx FPGA based digital circuit. One FPGA is needed to control and process the signal from a CMOS sensor for 20Hz region of interests (ROI) readout.

  14. Between occultism and drama. Henrik Ibsen and Aleister Crowley

    Directory of Open Access Journals (Sweden)

    Giuliano D' Amico

    2015-02-01

    Full Text Available The article investigates the references to the works of Henrik Ibsen that the writer and occultist Aleister Crowley scattered in his writings around the turn of the 20th century, in the early phase of his career as a writer and occultist. Crowley’s reading of Ibsen has a marked a socio-political bent, especially in his interpretation of the work of the Norwegian playwright as an act of rebellion against the bourgeois (and for Crowley, Victorian system of values. Also, such view is enriched by a spiritual and individualistic interpretation of Ibsen as an “Artist”, i.e., in the light of Crowley’s occult doctrine, Thelema, of an individual who has found his own “Will” and can inspire others to do so. Such social and spiritual interpretations of Ibsen on Crowley’s part found their literary realization in his one-act play The Mother’s Tragedy (1899. The article claims that Crowley’s reading of Ibsen can give some new insight in the mechanisms of reception of the Norwegian playwright, by opening up for a reading of some of his plays within an occult discourse. Also, it is an occasion to treat Crowley – a figure that was constantly present in the European cultural and literary life of the last decade of the 19th century and of the first five decades of the 20th – with a different attitude than the irony and disdain to which he is often exposed.

  15. Mapping Pluto's Temperature Distribution Through Twenty Years of Stellar Occultations

    Science.gov (United States)

    Zangari, Amanda; Binzel, R. P.; Person, M. J.

    2012-10-01

    Multi-chord, high signal-to-noise Pluto occultations have been observed several times over the past two decades, including events in 1988, 2002, 2006, 2007, 2010 and 2011 (Elliot et al. 1989, 2003, 2007; Person et al. 2008, 2010, 2011). We fit separate immersion and emersion occultation light-curve models to each of the individual light curves obtained from these efforts. Asymmetries in the light curves result in the half-light temperatures for opposite sides of a single chord to differ by up to 20 Kelvin in the largest case. The temperature difference for each chord is consistent using both isothermal (b=0) and non-isothermal (e.g. b=-2.2) models based on the methodology described by Elliot & Young (1992). We examine the relationship between the location of immersion and emersion points on Pluto and these temperatures at the half-light radius and will present results for correlations between these location/temperature data and surface composition maps, Pluto geometry, and accumulated insolation patterns. This work was supported by NASA Planetary Astronomy Grant to MIT (NNX10AB27G), and NSF Astronomy and Astrophysics Grant to MIT (0707609). The authors would like to acknowledge the late Professor James L. Elliot for his efforts in beginning this work. References: Elliot, J. L., Dunham, E. W., Bosh, A. S., et al. 1989, Icarus, 77,148 Elliot, J. L., Ates, A., Babcock, B. A., et al. 2003, Nature, 424,165 Elliot, J. L., Person, M. J., Gulbis, A. A. S., et al. 2007, AJ, 134, 1 Elliot, J. L., & Young, L. A. 1992, AJ, 103, 991. Person, M. J., Elliot, J. L., Gulbis, A. A. S., et al. 2008, AJ, 136, 1510 Person, M. J., Elliot, J. L., Bosh, A. S., et al. 2010, Bulletin of the American Astronomical Society, 42, 983 Person, M. J., Dunham, E. W., Bida, T., et al. 2011, EPSC-DPS Joint Meeting 2011, 1374.

  16. Magellan radio occultation measurements of atmospheric waves on Venus

    Science.gov (United States)

    Hinson, David P.; Jenkins, J. M.

    1995-01-01

    Radio occultation experiments were conducted at Venus on three consecutive orbits of the Magellan spacecraft in October 1991. Each occultation occurred over the same topography (67 deg N, 127 deg E) and at the same local time (22 hr 5 min), but the data are sensitive to zonal variations because the atmosphere rotates significantly during one orbit. Through comparisons between observations and predictions of standard wave theory, we have demonstrated that small-scale oscillations in retrieved temperature profiles as well as scintillations in received signal intensity are caused by a spectrum of vertically propagating internal gravity waves. There is a strong similarity between the intensity scintillations observed here and previous measurements, which pertain to a wide range of locations and experiment dates. This implies that the same basic phenomenon underlies all the observations and hence that gravity waves are a persistent, global feature of Venus' atmosphere. We obtained a fairly complete characterization of a gravity wave that appears above the middle cloud in temperature measurements on all three orbits. The amplitude and vertical wavelength are about 4 K and 2.5 km respectively, at 65 km. A model for radiative damping implies that the wave intrinsic frequency is approximately 2 x 10(exp 4) rad/sec, the corresponding ratio between horizontal and vertical wavelengths is approximately 100. The wave is nearly stationary relative to the surface or the Sun. Radiative attenuation limits the wave amplitude at altitudes above approximately 65 km, leading to wave drag on the mean zonal winds of about +0.4 m/sec per day (eastward). The sign, magnitude, and location of this forcing suggest a possible role in explaining the decrease with height in the zonal wind speed that is believed to occur above the cloud tops. Temperature oscillations with larger vertical wavelengths (5-10 km) were also observed on all three orbits, but we are able unable to interpret these

  17. Clinical experience with 111In tropolonate leucocytes in the detection of occult infection

    International Nuclear Information System (INIS)

    Wraight, E.P.

    1988-01-01

    Over a period of 3 years, 275 scans were performed in 233 patients with suspected occult sepsis. A firm diagnosis was ultimately established in 160 cases. 81 sites of infection were correctly identified and there were 77 true negative studies. There were 4 false negative and 7 false positive studies, most of which were due to misinterpreting bowel activity as sepsis and vice versa. In 56 cases CT scans were performed within a few days of the leucocyte study. There was good agreement between the findings. Comparison was possible with ultrasound in 81 cases. In 15 of these ultrasound failed to detect infection in the abdomen which was demonstrated by 111 In leucocytes, suggesting that ultrasound is much less sensitive in this situation. The overall accuracy of 111 In leucocyte scanning in this series was 93,5%. The predictive value of a positive result was 92% and of a negative one 95%. The need for serial images to distinguish bowel activity (colitis or swallowed activity) from paracolic sepsis is emphasised. (orig.)

  18. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  19. Occult pneumothorax in the blunt trauma patient: tube thoracostomy or observation?

    Science.gov (United States)

    Wilson, Heather; Ellsmere, James; Tallon, John; Kirkpatrick, Andrew

    2009-09-01

    The term occult pneumothorax (OP) describes a pneumothorax that is not suspected on the basis of either clinical examination or initial chest radiography, but is subsequently detected on computed tomography (CT) scan. The optimal management of OP in the blunt trauma setting remains controversial. Some physicians favour placement of a thoracostomy tube for patients with OP, particularly those undergoing positive pressure ventilation (PPV), while others favour close observation without chest drainage. This study was conducted both to determine the incidence of OP and to describe its current treatment status in the blunt trauma population at a Canadian tertiary trauma centre. Of interest were the rates of tube thoracostomy vs. observation without chest drainage and their respective outcomes. A retrospective review was conducted of the Nova Scotia Trauma Registry. The data on all consecutive blunt trauma patients between October 1994 and March 2003 was reviewed. Outcome measures evaluated include length of stay, discharge status-dead vs. alive, intervention and time to intervention (tube thoracostomy and its relation to institution of PPV). Direct comparison was made between the OP with tube thoracostomy group and OP without tube thoracostomy group (observation or control group). They were compared in terms of their baseline characteristics and outcome measures. In 1881 consecutive blunt trauma patients over a 102-month period there were 307 pneumothoraces of which 68 were occult. Thirty five patients with OP underwent tube thoracostomy, 33 did not. Twenty nine (82.8%) with tube thoracostomy received positive pressure ventilation (PPV), as did 16 (48.4%) in the observation group. Mean injury severity score (ISS) for tube thoracostomy and observation groups were similar (25.80 and 22.39, p=0.101) whereas length of stay (LOS) was different (17.4 and 10.0 days, p=0.026). Mortality was similar (11.4% and 9.1%). There were no tension pneumothoraces. The natural history of

  20. Enhanced bilateral somatostatin receptor expression in mediastinal lymph nodes (''chimney sign'') in occult metastatic medullary thyroid cancer: a typical site of tumour manifestation?

    International Nuclear Information System (INIS)

    Behr, T.M.; Gratz, S.; Markus, P.M.; Dunn, R.M.; Huefner, M.; Becker, H.; Becker, W.

    1997-01-01

    In medullary thyroid cancer (MTC), post-surgically elevated plasma calcitonin and/or carcinoembryonic antigen levels frequently indicate persisting metastatic disease, although conventional diagnostic procedures fail to localize the responsible lesions (occult disease). Somatostatin analogues have been used successfully in disease localization, but recently concerns have been raised that increased thoracic uptake of indium-111 pentetreotide in patients with previous external beam irradiation may represent a false-positive finding, caused by post-irradiation pulmonary fibrosis. We recently examined seven patients with metastatic MTC by somatostatin receptor scintigraphy (six with occult and one with established disease). In four patients, all of whom had stable or slowly rising tumour marker levels over several years, a chimney-like bilateral mediastinal uptake of indium-111 pentetreotide was found. In two patients with persisting hypercalcitonaemia immediately after primary surgery, supraclavicular lymph node metastases were identified as the responsible lesions. None of these seven patients had prior external beam radiation therapy. In two cases, histological confirmation was obtained. In one patient, disease progression could be shown during follow-up. These data suggest that bilateral mediastinal lymph node involvement is a typical site of disease in slowly progressing occult metastatic MTC; the ''chimney sign'' may represent a typical finding with somatostatin analogues in such cases. Therefore, we believe that even in the case of prior external beam irradiation, mediastinal uptake of octreotide might represent metastatic MTC rather than radiation fibrosis. (orig.). With 2 figs., 1 tab

  1. Urine cytology in the evaluation of urological malignancy revisited: is it still necessary?

    LENUS (Irish Health Repository)

    Falebita, Opeyemi Adegboyega

    2012-01-31

    OBJECTIVE: We aim to determine if urine cytology was still necessary as a routine part of the evaluation for the presence of urological malignancy and to evaluate its cost effectiveness. METHODS: Urine cytology reports over a 6-year period (2000-2005) were retrieved from our institution\\'s pathology department database. Patients with urine cytology positive for malignant cells were identified. We retrospectively reviewed the charts of these patients for age, sex, flexible cystoscopy and radiological imaging results. The cost of urine cytology was retrieved from the pathology department. RESULTS: There were a total of 2,568 urine cytological examinations. Of these, 25 were positive for malignant cells. There were 19 male (76%) and 6 female (24%) patients with a mean age of 72 years (range: 49-97). In 21 patients with positive cytology, a bladder tumor was identified at flexible cystoscopy and\\/or imaging studies. For a positive cytology yield of 1%, EUR 210,000 was spent. CONCLUSIONS: Routine urine cytology was not cost effective and did not add to the diagnostic yield beyond cystoscopy and diagnostic imaging. It may be omitted in the initial evaluation of urological malignancy.

  2. Cause-Specific Mortality According to Urine Albumin Creatinine Ratio in the General Population

    DEFF Research Database (Denmark)

    Skaaby, Tea; Husemoen, Lise Lotte Nystrup; Ahluwalia, Tarun Veer Singh

    2014-01-01

    BACKGROUND: Urine albumin creatinine ratio, UACR, is positively associated with all-cause mortality, cardiovascular disease and diabetes in observational studies. Whether a high UACR is also associated with other causes of death is unclear. We investigated the association between UACR and cause......-specific mortality. METHODS: We included a total of 9,125 individuals from two population-based studies, Monica10 and Inter99, conducted in 1993-94 and 1999-2001, respectively. Urine albumin creatinine ratio was measured from spot urine samples by standard methods. Information on causes of death was obtained from...

  3. Fecal Occult Blood Test (FOBT): MedlinePlus Lab Test Information

    Science.gov (United States)

    ... caused by a variety of conditions, including: Polyps Hemorrhoids Diverticulosis Ulcers Colitis , a type of inflammatory bowel ... on a fecal occult blood test include ulcers, hemorrhoids, polyps, and benign tumors. If your test results ...

  4. Observations of Hot-Jupiter occultations combining Spitzer and Kepler photometry

    Directory of Open Access Journals (Sweden)

    Knutson H.

    2011-02-01

    Full Text Available We present the status of an ongoing program which aim at measuring occultations by their parent stars of transiting hot giant exoplanets discovered recently by Kepler. The observations are obtained in the near infrared with WarmSpitzer Space Telescope and at optical wavelengths by combining more than a year of Kepler photometry. The investigation consists of measuring the mid-occultation times and the relative occultation depths in each band-passes. Our measurements of occultations depths in the Kepler bandpass is turned into the determination of the optical geometric albedo Ag in this wavelength domain. The brightness temperatures of these planets are deduced from the infrared observations. We combine the optical and near infrared planetary emergent fluxes to obtain broad band emergent spectra of individual planet. We finally compare these spectra to hot Jupiter atmospheric models in order broadly distinguishing these atmospheres between different classes of models.

  5. Parapsychology on the couch: the psychology of occult belief in Germany, c. 1870-1939.

    Science.gov (United States)

    Wolffram, Heather

    2006-01-01

    This article considers the attempts of academic psychologists and critical occultists in Germany during the late nineteenth and early twentieth centuries to construct a psychology of occult belief. While they claimed that the purpose of this new subdiscipline was to help evaluate the work of occult researchers, the emergence of a psychology of occult belief in Germany served primarily to pathologize parapsychology and its practitioners. Not to be outdone, however, parapsychologists argued that their adversaries suffered from a morbid inability to accept the reality of the paranormal. Unable to resolve through experimental means the dispute over who should be allowed to mold the public's understanding of the occult, both sides resorted to defaming their opponent. (c) 2006 Wiley Periodicals, Inc.

  6. Metastatic Squamous Neck Cancer with Occult Primary Treatment (PDQ®)—Health Professional Version

    Science.gov (United States)

    Metastatic squamous neck cancer with occult primary treatment options include surgery, radiation therapy or a combination of both. Get detailed information about newly diagnosed or recurrent metastatic squamous neck cancer in this summary for clinicians.

  7. Metastatic Squamous Neck Cancer with Occult Primary Treatment (PDQ®)—Patient Version

    Science.gov (United States)

    Metastatic squamous neck cancer with occult primary (unknown primary) treatment options include surgery, radiation therapy, or a combination of both. Learn more about the diagnosis and treatment of these tumors in this expert-reviewed summary.

  8. Low-Cost Small Satellite Atmospheric Rotating Solar Occultation Imager (ROI)

    Data.gov (United States)

    National Aeronautics and Space Administration — Utilizing a unique, new occultation technique involving imaging, the ROI concept will meet or exceed the quality of SAGE measurements at a small fraction of the...

  9. Prevalence of Visible and Occult Blood on the Surfaces of Fiberoptic Bronchoscopes

    National Research Council Canada - National Science Library

    McKamey, Jeffrey

    2000-01-01

    .... This study was conducted to determine if current cleaning, disinfection and sterilization procedures used at one medical center was adequate to remove visible and occult blood from fiberoptic bronchoscopes...

  10. Patterns of hepatitis B virus infection in Brazilian human immunodeficiency virus infected patients: high prevalence of occult infection and low frequency of lamivudine resistant mutations

    Directory of Open Access Journals (Sweden)

    Michel VF Sucupira

    2006-09-01

    Full Text Available Hepatitis B virus (HBV molecular profiles were determined for 44 patients who were infected with human immunodeficiency virus (HIV type 1 and had antibodies to the hepatitis B core antigen (anti-HBc, with and without other HBV serological markers. In this population, 70% of the patients were under lamivudine treatment as a component of antiretroviral therapy. HBV DNA was detected in 14 (32% patients. Eight out of 12 (67% HBsAg positive samples, 3/10 (30% anti-HBc only samples, and 3/22 (14% anti-HBs positive samples were HBV DNA positive. HBV DNA loads, measured by real time polymerase chain reaction, were much higher in the HBsAg positive patients (mean, 2.5 × 10(9 copies/ml than in the negative ones (HBV occult infection; mean, 2.7 × 10(5 copies/ml. Nine out of the 14 HBV DNA positive patients were under lamivudine treatment. Lamivudine resistant mutations in the polymerase gene were detected in only three patients, all of them belonging to the subgroup of five HBsAg positive, HBV DNA positive patients. A low mean HBV load (2.7 × 10(5 copies/ml and an absence of lamivudine resistant mutations were observed among the cases of HBV occult infection.

  11. POPULATION BASED COLORECTAL CANCER SCREENING: COMPARISON OF TWO FAECAL OCCULT BLOOD TESTS

    Directory of Open Access Journals (Sweden)

    Miren Begoña eZubero

    2014-01-01

    Full Text Available Background: The aim of screening for colorectal cancer is to improve prognosis by the detection of cancer at its early stages. In order to inform the decision on the specific test to be used in the population-based programme in the Basque Autonomous Region (Spain, we compared two immunochemical faecal occult blood quantitative tests (I-FOBT. Methods: Residents of selected study areas, aged 50-69 years, were invited to participate in the screening. Two tests based on latex agglutination (OC-Sensor and FOB Gold were randomly assigned to different study areas. A colonoscopy was offered to patients with a positive test result. The cut-off point used to classify a result as positive, according to manufacturer’s recommendations, was 100 ng/ml for both tests. Results: The invited population included 37,999 individuals. Participation rates were 61.8% (n=11,162 for OC-Sensor and 59.1% (n=11,786 for FOB Gold, (p=0.008. Positive rate for OC-Sensor was 6.6% (n=737 and 8.5% (n=1,002 for FOB Gold, (pConclusions: OC-Sensor test appears to be superior for I-FOBT based CRC screening, given its acceptance, ease of use, associated small number of errors and its screening accuracy. FOB-Gold on the other hand, has higher rate of positive values, with more colonoscopies performed, it shows higher detection incidence rates, but involves more false positives.

  12. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    Science.gov (United States)

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  13. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test (Video) Print en español Obtención de un análisis de orina (video) It ...

  14. Odors from evaporation of acidified pig urine

    NARCIS (Netherlands)

    Willers, H.C.; Hobbs, P.J.; Ogink, N.W.M.

    2004-01-01

    In the Dutch Hercules project feces and urine from pigs are collected separately underneath the slatted floor in a pig house and treated in two processes. Feces are composted and urine is concentrated by water evaporation in a packed bed. Exhaust air from the pig house is used for the evaporation in

  15. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... site Sitio para adolescentes Body Mind Sexual Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test ( ...

  16. The determination of 210Po in urine

    International Nuclear Information System (INIS)

    Bale, W.F.; Helmkamp, R.W.; Hrynyszyn, V.; Contreras, M.A.

    1975-01-01

    To measure 210 Po present in normal human urine a technique was developed in which a 4.5 x 11cm silver foil was shaken at room temperature for 48-hr periods in each of two successive volumes of 1.7 l. of urine acidified to 0.5N with HCl. Alpha rays were counted with an ionization chamber, coupled to a vibrating reed electrometer, and capable of measuring α-ray pulses originating on both sides of the silver foil serving as a central electrode. The background α-count was less than 2/hr. Analyses of human urine spiked with 0.29 to 0.58pCi of 210 Po, together with studies of urine from dogs carrying significant body burdens of 210 Pb, indicated that the average recovery of added 210 Po from 1.7 l. volumes of spiked human urine was 72%. If it is assumed that the same percentage of 210 Po is extracted from non-spiked urine, then the average 210 Po concentration found in 13 analyses of 2 x 1.7 l. samples from 26 different pools of fresh human urine was 0.023pCi/l. Substantial additional 210 Po was generated on short aging of the urine through radioactive decay of excreted 210 Bi. (author)

  17. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test (Video) Print en español ...

  18. Elevated CXC chemokines in urine noninvasively discriminate OAB from UTI.

    Science.gov (United States)

    Tyagi, Pradeep; Tyagi, Vikas; Qu, Xianggui; Chuang, Yao Chi; Kuo, Hann-Chorng; Chancellor, Michael

    2016-09-01

    Overlapping symptoms of overactive bladder (OAB) and urinary tract infection (UTI) often complicate the diagnosis and contribute to overprescription of antibiotics. Inflammatory response is a shared characteristic of both UTI and OAB and here we hypothesized that molecular differences in inflammatory response seen in urine can help discriminate OAB from UTI. Subjects in the age range of (20-88 yr) of either sex were recruited for this urine analysis study. Urine specimens were available from 62 UTI patients with positive dipstick test before antibiotic treatment. Six of these patients also provided urine after completion of antibiotic treatment. Subjects in cohorts of OAB (n = 59) and asymptomatic controls (n = 26) were negative for dipstick test. Urinary chemokines were measured by MILLIPLEX MAP Human Cytokine/Chemokine Immunoassay and their association with UTI and OAB was determined by univariate and multivariate statistics. Significant elevation of CXCL-1, CXCL-8 (IL-8), and CXCL-10 together with reduced levels for a receptor antagonist of IL-1A (sIL-1RA) were seen in UTI relative to OAB and asymptomatic controls. Elevated CXCL-1 urine levels predicted UTI with odds ratio of 1.018 and showed a specificity of 80.77% and sensitivity of 59.68%. Postantibiotic treatment, reduction was seen in all CXC chemokines with a significant reduction for CXCL-10. Strong association of CXCL-1 and CXCL-10 for UTI over OAB indicates mechanistic differences in signaling pathways driving inflammation secondary of infection in UTI compared with a lack of infection in OAB. Urinary chemokines highlight molecular differences in the paracrine signaling driving the overlapping symptoms of UTI and OAB. Copyright © 2016 the American Physiological Society.

  19. Detection of an occult transclival cerebrospinal fluid fistula by CT and MRI

    International Nuclear Information System (INIS)

    Schick, B.; Brors, D.; Draf, W.; Goedecke, A.; Prescher, A.

    1998-01-01

    We describe an unusual occult transclival cerebrospinal fluid (CSF) fistula to the sphenoid sinus demonstrated by MRI. CT was performed because of a posterior cerebral infarct caused by cardiac arrhythmia. Axial sections showed fluid in the sphenoid sinus. High-resolution scans revealed a bony defect 3 mm in diameter of the posterior wall of the sphenoid sinus, and MRI showed a transclival CSF fistula. This occult lesion was confirmed by surgery and duraplasty was successfully performed via an endonasal approach. (orig.)

  20. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    Science.gov (United States)

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of

  1. A prospective evaluation of occult disorders in obstructed defecation using the 'iceberg diagram'.

    Science.gov (United States)

    Pescatori, M; Spyrou, M; Pulvirenti d'Urso, A

    2007-06-01

    Surgical treatment of constipation and obstructed defecation (OD) carries frequent recurrences, as OD is an 'iceberg syndrome' characterized by 'underwater rocks' or occult diseases which may affect the outcome of surgery. The aim of this study was to evaluate occult disorders, in order to alert the clinician of these and minimize failures. One hundred consecutive constipated patients with OD symptoms, 81 women, median age 52 years, underwent perineal examination, proctoscopy, anorectal manometry and anal/vaginal ultrasound (US). Anorectal physiology and imaging tests were also carried out when indicated, as well as psychological and urogynaecological consultations. Symptoms were graded using a modified 1-20 constipation score. Both evident (e.g. rectocele) and occult (e.g. anismus) diseases were prospectively evaluated using a novel 'iceberg diagram'. The type of treatment, whether conservative or surgical, was also recorded. Fifty-four (54%) patients had both mucosal prolapse and rectocele. All patients had at least two occult OD-related diseases, 66 patients had at least three of them: anxiety-depression, anismus and rectal hyposensation were the most frequent (66%, 44% and 33%, respectively). The median constipation score was 11 (range 2-20), the median number of 'occult disorders' was 5 (range 2-8). Conservative treatment was carried out in most cases. Surgery was carried out in 14 (14%) patients. The novel 'iceberg diagram' allowed the adequate evaluation of OD-related occult diseases and better selection of patients for treatment. Most were managed conservatively, and only a minority were treated by surgery.

  2. Scaled model guidelines for solar coronagraphs' external occulters with an optimized shape.

    Science.gov (United States)

    Landini, Federico; Baccani, Cristian; Schweitzer, Hagen; Asoubar, Daniel; Romoli, Marco; Taccola, Matteo; Focardi, Mauro; Pancrazzi, Maurizio; Fineschi, Silvano

    2017-12-01

    One of the major challenges faced by externally occulted solar coronagraphs is the suppression of the light diffracted by the occulter edge. It is a contribution to the stray light that overwhelms the coronal signal on the focal plane and must be reduced by modifying the geometrical shape of the occulter. There is a rich literature, mostly experimental, on the appropriate choice of the most suitable shape. The problem arises when huge coronagraphs, such as those in formation flight, shall be tested in a laboratory. A recent contribution [Opt. Lett.41, 757 (2016)OPLEDP0146-959210.1364/OL.41.000757] provides the guidelines for scaling the geometry and replicate in the laboratory the flight diffraction pattern as produced by the whole solar disk and a flight occulter but leaves the conclusion on the occulter scale law somehow unjustified. This paper provides the numerical support for validating that conclusion and presents the first-ever simulation of the diffraction behind an occulter with an optimized shape along the optical axis with the solar disk as a source. This paper, together with Opt. Lett.41, 757 (2016)OPLEDP0146-959210.1364/OL.41.000757, aims at constituting a complete guide for scaling the coronagraphs' geometry.

  3. Extent and kinetics of recovery of occult spinal cord injury

    International Nuclear Information System (INIS)

    Ang, K. Kian; Jiang, G.-L.; Feng Yan; Stephens, L. Clifton; Tucker, Susan L.; Price, Roger E.

    2001-01-01

    Purpose: To obtain clinically useful quantitative data on the extent and kinetics of recovery of occult radiation injury in primate spinal cord, after a commonly administered elective radiation dose of 44 Gy, given in about 2 Gy per fraction. Methods and Materials: A group of 56 rhesus monkeys was assigned to receive two radiation courses to the cervical and upper thoracic spinal cord, given in 2.2 Gy per fraction. The dose of the initial course was 44 Gy in all monkeys. Reirradiation dose was 57.2 Gy, given after 1-year (n 16) or 2-year (n = 20) intervals, or 66 Gy, given after 2-year (n = 4) or 3-year (n = 14) intervals. Two animals developed intramedullary tumors before reirradiation and, therefore, did not receive a second course. The study endpoint was myeloparesis, manifesting predominantly as lower extremity weakness and decrease in balance, occurring within 2.5 years after reirradiation, complemented by histologic examination of the spinal cord. The data obtained were analyzed along with data from a previous study addressing single-course tolerance, and data from a preliminary study of reirradiation tolerance. Results: Only 4 of 45 monkeys completing the required observation period (2-2.5 years after reirradiation, 3-5.5 years total) developed myeloparesis. The data revealed a substantial recovery of occult injury induced by 44 Gy within the first year, and suggested additional recovery between 1 and 3 years. Fitting the data with a model, assuming that all (single course and reirradiation) dose-response curves were parallel, yielded recovery estimates of 33.6 Gy (76%), 37.6 Gy (85%), and 44.6 Gy (101%) of the initial dose, after 1, 2, and 3 years, respectively, at the 5% incidence (D 5 ) level. The most conservative estimate, using a model in which it was assumed that there was no recovery between 1 and 3 years following initial irradiation and that the combined reirradiation curve was not necessarily parallel to the single-course curve, still showed an

  4. Protein in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/proteininurine.html Protein in Urine To use the sharing features on this page, please enable JavaScript. What is a Protein in Urine Test? A protein in urine test ...

  5. Ethanol Induced Urine Acidification is Related with Early Acetaldehyde Concentration

    Directory of Open Access Journals (Sweden)

    Soon Kil Kwon

    2014-06-01

    Conclusion: In conclusion, urine acidification after ethanol ingestion is related with serum acetaldehyde concentration. Early elevation of acetaldhyde could induce urine acidification, but the urine pH was elevated after a few hours, that might make prolonged acidemia.

  6. Inversion, error analysis, and validation of GPS/MET occultation data

    Directory of Open Access Journals (Sweden)

    A. K. Steiner

    Full Text Available The global positioning system meteorology (GPS/MET experiment was the first practical demonstration of global navigation satellite system (GNSS-based active limb sounding employing the radio occultation technique. This method measures, as principal observable and with millimetric accuracy, the excess phase path (relative to propagation in vacuum of GNSS-transmitted radio waves caused by refraction during passage through the Earth's neutral atmosphere and ionosphere in limb geometry. It shows great potential utility for weather and climate system studies in providing an unique combination of global coverage, high vertical resolution and accuracy, long-term stability, and all-weather capability. We first describe our GPS/MET data processing scheme from excess phases via bending angles to the neutral atmospheric parameters refractivity, density, pressure and temperature. Special emphasis is given to ionospheric correction methodology and the inversion of bending angles to refractivities, where we introduce a matrix inversion technique (instead of the usual integral inversion. The matrix technique is shown to lead to identical results as integral inversion but is more directly extendable to inversion by optimal estimation. The quality of GPS/MET-derived profiles is analyzed with an error estimation analysis employing a Monte Carlo technique. We consider statistical errors together with systematic errors due to upper-boundary initialization of the retrieval by a priori bending angles. Perfect initialization and properly smoothed statistical errors allow for better than 1 K temperature retrieval accuracy up to the stratopause. No initialization and statistical errors yield better than 1 K accuracy up to 30 km but less than 3 K accuracy above 40 km. Given imperfect initialization, biases >2 K propagate down to below 30 km height in unfavorable realistic cases. Furthermore, results of a statistical validation of GPS/MET profiles through comparison

  7. The Prevalence of Occult Celiac Disease among Patients with Functional Dyspepsia: A Study from the Western Region of Iran

    Directory of Open Access Journals (Sweden)

    Ali Asghar Keshavarz

    2010-01-01

    Full Text Available Objective. The prevalence of Celiac Disease (CD is high in Iran, and evaluation of CD is not part of the routine screening procedure for dyspeptic patients; therefore, cases of occult CD may be missed. This study aimed to investigate the prevalence of occult CD among dyspeptic patients who presented at a gastroenterology clinic in the Western region of Iran. Methods. In this descriptive, cross-sectional prospective study, patients who had a history of at least 12 weeks of upper abdominal discomfort were eligible to participate in the study during a 14-month recruitment period. Patients with a clinical or paraclinical data in favor of organic causes were excluded from the study. Enrolled patients were screened for IgA antiendomysium antibody (EMA and IgA antitissue transglutaminase antibody (tTG. Those who screened positive for EMA/tTG received a confirmatory diagnostic biopsy for Marsh classification of CD. Results. From 225 potential participants with dyspepsia, 55 patients were excluded due to having explainable organic causes. The study sample included 170 patients with “functional dyspepsia.” Mean age of participants was 31 years and 55.8% were female. Twelve patients (7% had positive tests (EMA/tTG, of which 10 were female (83.4%. According to Rome II criteria, all twelve patients with positive tests had “dysmotility type dyspepsia.” Based on Marsh classification, six patients were consistent with “Marsh I,” four with “Marsh II,” and two with the “Marsh III” classification. Conclusions. In this study, the prevalence of CD in dyspeptic patients was high. As a result, this study suggests that screening by serology tests (EMA/tTG is justifiable for the detection of CD among functional dyspeptic patients in the tertiary centers in our country.

  8. [Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry].

    Science.gov (United States)

    Costa, Christian Elías; Bettendorff, Carolina; Bupo, Sol; Ayuso, Sandra; Vallejo, Graciela

    2010-06-01

    The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. To assess the accuracy of different methods to measure urine specific gravity. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

  9. For reliable urine cultures in the detection of complicated urinary tract infection, do we use urine specimens obtained with urethral catheter or a nephrostomy tube?

    Science.gov (United States)

    Dede, Gülay; Deveci, Özcan; Dede, Onur; Utanğac, Mazhar; Dağgulli, Mansur; Penbegül, Necmettin; Hatipoğlu, Namık Kemal

    2016-12-01

    The aim of this study was to compare the results of urine cultures obtained either from urethral, and percutaneous nephrostomy (PCN) catheters. This study included 328 consecutive patients that underwent PCN at our institution with complicated urinary tract infections (UTIs) between July 2010 and April 2015. Results of urine cultures obtained from the urethral and nephrostomy catheters were compared. This study included 152 male and 176 female patients. Mean age of the patients was 46.2±24.3 years. The main indications were obstructive uropathy due to urolithiasis complicated with pyonephrosis 145 (44%), malignant disease (n=87; 26%), pregnancy (n=26; 8%), and anatomical abnormality (n=23; 7%). One hundred and twenty three patients had diabetes mellitus. The most common causative organisms were Escherichia coli , Klebsiella pneumoniae , and Pseudomonas aeruginosa . Blood cultures showed the same results for the PCN and bladder urine cultures. The bladder urine culture was positive in 304 patients, while the PCN urine culture in 314 patients. PCN is an important treatment for the management of pyonephrosis. Cultures from the PCN yield valuable information that is not available from urethral urine cultures, and is a guiding tool for antibiotic therapy selection.

  10. Evaluation of urine mercury level of dentists in Tehran and its influencial factors

    Directory of Open Access Journals (Sweden)

    Tabatabaei M.

    2006-08-01

    Full Text Available Background and Aim: Dentists are exposed to mercury from dental amalgam in their routine occupational practice. Excess exposure to mercury is harmful and the measurement of mercury content of urine is a reliable and valid assessment of the level of mercury exposure from dental amalgam. The aim of this study was the measurement of urine mercury in dentists of Tehran and assessment of some possible related factors. Materials and Methods: This cross-sectional study was performed randomly on 211 dentists in all regions in Tehran city (center, north, south, west, and east between 1381 and 1383. Dentists were asked to give a sample of urine in the day of visit and to complete a questionnaire consisting of variables such as age, working history, handling of amalgam, environmental parameters and general health situation. Urine samples were analyzed by cold vapour atomic absorption spectrophotometry. Data were analyzed by Kruskall Walis, Kendall and Mann Whitney tests, with p<0.05 as the limit of significance. Results: The mean of urine mercury content in Tehran dentists was 3.1 (± 3.95 which was lower than the international TLV (Threshold Limit Value. There was a significant relation between urine mercury level and working hours per day (P=0.006. This relation was observed with working hours per week too (P=0.006. In general dentists, there was a positive relation between urine mercury and age (0.008 as well as the practicing years (P=0.034. A significant relation was found between urine mercury and the number of amalgam repairs and replacements in restorative specialists (p=0.039. There was a significant relation between the number of amalgam fillings in the mouth and urine mercury in general practitioners (p=0.027. The type of amalgam (predosed capsules or bulk powder had a significant effect on the urine mercury content (P=0.001. There was no significant relation between urine mercury and other variables of the study such as the squeezing of

  11. Nonhazardous Urine Pretreatment Method for Future Exploration Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A nonhazardous urine pretreatment system prototype is proposed that will stabilize urine against biological growth or chemical instabilities without using hazardous...

  12. Feline urine metabolomic signature: characterization of low-molecular-weight substances in urine from domestic cats.

    Science.gov (United States)

    Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F

    2018-02-01

    Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.

  13. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  14. Detection of Occult Erythrocytic Membrane Damages upon Pharmacological Exposures

    Directory of Open Access Journals (Sweden)

    P. Yu. Alekseyeva

    2007-01-01

    Full Text Available Blood administration of pharmaceuticals may cause occult effects of these agents on erythrocytic membranes. These effects may damage and cause additional membrane defects, but may strengthen. The type and degree of the effects of an agent were detected by calibrated irreversible electroporation with a pulsed electric field (PEF. The paper considers the erythrocytic membranous effects of a wide concentration range of agents used in anesthesiology, such as esmerone, tracrium, and mar-caine-adrenaline. Under the action of PEF and esmerone at the normal concentration N, the rate of erythrocytic hemolysis increased by several times as compared with the control. The similar effect also occurred when esmerone was added at the concentration C=10N. Tracrium exerted a fixing effect on erythrocytic membranes. Upon a combined exposure to PEF and tracrium in the normal concentration C=N; erythrocytic hemolysis was slow. So was with the concentration C=10N. The rate of hemolysis of the red blood cells subjected to a combined action of marcaine adrenaline at the normal concentration C=N and even at the concentration C=10N and PEF was comparable with the hemolytic rate of the reference suspension. 

  15. Occult radiological effects of lipomatosis of the lumbosacral plexus

    Energy Technology Data Exchange (ETDEWEB)

    Mahan, Mark A. [Barrow Neurological Institute, Phoenix, AZ (United States); Howe, B.M.; Amrami, Kimberly K. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Spinner, Robert J. [Mayo Clinic, Department of Neurosurgery, Rochester, MN (United States); Mayo Clinic, Department of Orthopedics, Rochester, MN (United States); Mayo Clinic, Rochester, MN (United States)

    2014-07-15

    Lipomatosis of nerve (LN) is a condition of massive peripheral nerve enlargement frequently associated with hypertrophy within the distribution of the nerve, and most commonly affecting the distal limbs. We sought to understand if LN of the lumbosacral plexus would be associated with the trophic effects of LN on surrounding tissue within the pelvis, which may be clinically occult, but present on MRI. Fifty-one cases of LN, confirmed by pathology or pathognomonic appearance on MRI, were reviewed. Patients with LN of the sciatic nerve were investigated for radiological signs suggestive of overgrowth. Five patients had involvement of the sciatic nerve, 4 of whom had MR imaging of the pelvis. Three patients had LN involving the lumbosacral plexus, and one patient had isolated involvement of the sciatic nerve. All patients with involvement of the lumbosacral plexus demonstrated previously unrecognized evidence of nerve territory overgrowth in the pelvis, including: LN, profound adipose proliferation, muscle atrophy and fatty infiltration, and bone hypertrophy and ankylosis. The patient with LN involving the intrapelvic sciatic nerve, but not the lumbosacral plexus did not demonstrate any radiological evidence of pelvic overgrowth. LN is broader in anatomical reach than previously understood. Proximal plexal innervation may be involved, with a consequent effect on axial skeleton and intrapelvic structures. (orig.)

  16. Cassini-VIMS at Jupiter: Solar occultation measurements using Io

    Science.gov (United States)

    Formisano, V.; D'Aversa, E.; Bellucci, G.; Baines, K.H.; Bibring, J.-P.; Brown, R.H.; Buratti, B.J.; Capaccioni, F.; Cerroni, P.; Clark, R.N.; Coradini, A.; Cruikshank, D.P.; Drossart, P.; Jaumann, R.; Langevin, Y.; Matson, D.L.; McCord, T.B.; Mennella, V.; Nelson, R.M.; Nicholson, P.D.; Sicardy, B.; Sotin, Christophe; Chamberlain, M.C.; Hansen, G.; Hibbits, K.; Showalter, M.; Filacchione, G.

    2003-01-01

    We report unusual and somewhat unexpected observations of the jovian satellite Io, showing strong methane absorption bands. These observations were made by the Cassini VIMS experiment during the Jupiter flyby of December/January 2000/2001. The explanation is straightforward: Entering or exiting from Jupiter's shadow during an eclipse, Io is illuminated by solar light which has transited the atmosphere of Jupiter. This light, therefore becomes imprinted with the spectral signature of Jupiter's upper atmosphere, which includes strong atmospheric methane absorption bands. Intercepting solar light refracted by the jovian atmosphere, Io essentially becomes a "miffor" for solar occultation events of Jupiter. The thickness of the layer where refracted solar light is observed is so large (more than 3000 km at Io's orbit), that we can foresee a nearly continuous multi-year period of similar events at Saturn, utilizing the large and bright ring system. During Cassini's 4-year nominal mission, this probing tecnique should reveal information of Saturn's atmosphere over a large range of southern latitudes and times. ?? 2003 Elsevier Inc. All rights reserved.

  17. Occult hepatitis B infection and transfusion-transmission risk.

    Science.gov (United States)

    Candotti, D; Boizeau, L; Laperche, S

    2017-09-01

    Advances in serology and viral nucleic acid testing (NAT) over the last decades significantly reduced the risk of transfusion-transmitted hepatitis B virus (HBV). The combination of HBsAg testing and NAT efficiently prevents the majority of HBV transmission. However, a specific residual risk remains associated with extremely low viral DNA levels in blood donors with occult HBV infection (OBI) that are intermittently or not detectable even by highly sensitive individual donation (ID) NAT. Studies have reported HBV transfusion-transmission with blood components from donors with OBI that contained low amount of viruses (transfusion-transmission seems to depend on a combination of several factors including the volume of plasma associated with the infected blood components transfused, the anti-HBV immune status of both recipient and donor, and possibly the viral fitness of the infecting HBV strain. Models based on clinical and experimental evidences estimate a residual transmission risk of 3-14% associated with OBI donations testing HBsAg and ID-NAT non-reactive. Anti-HBc testing has the potential to improve further blood safety but it may also compromise blood availability in settings with medium/high HBV prevalence. Pathogen reduction procedures might be considered. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Ectoparasites of the occult bat, Myotis occultus (Chiroptera: Vespertilionidae)

    Science.gov (United States)

    Valdez, Ernest W.; Ritzi, Christopher M.; Whitaker, John O.

    2009-01-01

    Only a single previous study has examined ectoparasites of the occult bat (Myotis occultus), from which only 2 species of fleas were identified. For our study, we examined 202 individuals, 52 fresh hosts and 150 museum specimens, from New Mexico and southern Colorado for ectoparasites. We recorded 2158 ectoparasites, 634 from fresh hosts and 1524 from museum specimens. Ectoparasites belonged to 10 families and 13 genera of insect or acari and represent new host and locality records. In general, ectoparasites collected from fresh hosts and museum specimens were represented by 4 major species of mite: Macronyssus crosbyi, Alabidocarpus calcaratus, Acanthophthirius lucifugus, and Alabidocarpus nr. eptesicus. From our study, we found fresh hosts to have significantly greater prevalence values for Myodopsylla gentilis (flea), Chiroptonyssus robustipes (mite), and Leptotrombidium myotis (chigger), whereas museum specimens had significantly greater prevalence values for A. calcaratus(mite) and A. nr. eptesicus (mite). There were no significant differences between prevalence values for 4 mites including M. crosbyi, A. lucifugus, Pteracarus nr. minutus, and Cryptonyssussp. Our study represents the only extensive study of ectoparasites on M. occultus and provides evidence for the importance of examining fresh hosts and museum specimens in future ectoparasite studies.

  19. MRI of occult sacral insufficiency fractures following radiotherapy

    International Nuclear Information System (INIS)

    Mammone, J.F.; Schweitzer, M.E.

    1995-01-01

    Following radiation therapy, marrow abnormalities noted on magnetic resonance imaging (MRI) are frequent and may mimic metastases. Specific radiotherapy changes are usually easily identifiable; however, traumatic lesions cause more interpretive difficulties. We assessed the incidence and MRI characteristics of insufficiency fractures in this population. During a 5-year span (1987-1991), 546 patients received pelvic radiotherapy for primary malignancies. MRI was performed in 25 of these patients at least 3 months after treatment. The mean dose in this group was 53 Gy. These MRI scans were retrospectively reviewed for the appearance of the sacrum with particular attention to the presence of insufficiency fractures. This was correlated with clinical course and scintigraphic findings. Presumed insufficiency fractures on MRI paralleled the sacral side of the sacroiliac joint, enhanced with Gd-DTPA, were most prominent or initially seen anteriorly, and had ill-defined margins on all imaging sequences. The incidence of occult sacral insufficiency fractures was at least 20%. Insufficiency fractures of the sacrum in the post-radiotherapy patient are a relatively frequent occurrence which can mimic metastases. Consideration of this phenomenon and knowledge of differential features may avoid overdiagnosis of osseous metastases. (orig.)

  20. Atmospheric diurnal variations observed with GPS radio occultation soundings

    Directory of Open Access Journals (Sweden)

    F. Xie

    2010-07-01

    Full Text Available The diurnal variation, driven by solar forcing, is a fundamental mode in the Earth's weather and climate system. Radio occultation (RO measurements from the six COSMIC satellites (Constellation Observing System for Meteorology, Ionosphere and Climate provide nearly uniform global coverage with high vertical resolution, all-weather and diurnal sampling capability. This paper analyzes the diurnal variations of temperature and refractivity from three-year (2007–2009 COSMIC RO measurements in the troposphere and stratosphere between 30° S and 30° N. The RO observations reveal both propagating and trapped vertical structures of diurnal variations, including transition regions near the tropopause where data with high vertical resolution are critical. In the tropics the diurnal amplitude in refractivity shows the minimum around 14 km and increases to a local maximum around 32 km in the stratosphere. The upward propagating component of the migrating diurnal tides in the tropics is clearly captured by the GPS RO measurements, which show a downward progression in phase from stratopause to the upper troposphere with a vertical wavelength of about 25 km. At ~32 km the seasonal variation of the tidal amplitude maximizes at the opposite side of the equator relative to the solar forcing. The vertical structure of tidal amplitude shows strong seasonal variations and becomes asymmetric along the equator and tilted toward the summer hemisphere in the solstice months. Such asymmetry becomes less prominent in equinox months.

  1. Information content in reflected signals during GPS Radio Occultation observations

    Science.gov (United States)

    Aparicio, Josep M.; Cardellach, Estel; Rodríguez, Hilda

    2018-04-01

    The possibility of extracting useful information about the state of the lower troposphere from the surface reflections that are often detected during GPS radio occultations (GPSRO) is explored. The clarity of the reflection is quantified, and can be related to properties of the surface and the low troposphere. The reflected signal is often clear enough to show good phase coherence, and can be tracked and processed as an extension of direct non-reflected GPSRO atmospheric profiles. A profile of bending angle vs. impact parameter can be obtained for these reflected signals, characterized by impact parameters that are below the apparent horizon, and that is a continuation at low altitude of the standard non-reflected bending angle profile. If there were no reflection, these would correspond to tangent altitudes below the local surface, and in particular below the local mean sea level. A forward operator is presented, for the evaluation of the bending angle of reflected GPSRO signals, given atmospheric properties as described by a numerical weather prediction system. The operator is an extension, at lower impact parameters, of standard bending angle operators, and reproduces both the direct and reflected sections of the measured profile. It can be applied to the assimilation of the reflected section of the profile as supplementary data to the direct section. Although the principle is also applicable over land, this paper is focused on ocean cases, where the topographic height of the reflecting surface, the sea level, is better known a priori.

  2. SOLAR OCCULTATION BY TITAN MEASURED BY CASSINI/UVIS

    Energy Technology Data Exchange (ETDEWEB)

    Capalbo, Fernando J.; Benilan, Yves [Laboratoire Interuniversitaire des Systemes Atmospheriques (LISA), UMR 7583 du CNRS, Universites Paris Est Creteil (UPEC) and Paris Diderot - UPD, 61 avenue du General de Gaulle, 94010 Creteil Cedex (France); Yelle, Roger V.; Koskinen, Tommi T.; Sandel, Bill R. [Lunar and Planetary Laboratory, University of Arizona, 1629 E. University Blvd., Tucson, AZ 85721 (United States); Holsclaw, Gregory M.; McClintock, William E., E-mail: fernando.capalbo@lisa.u-pec.fr [Laboratory for Atmospheric and Space Physics, University of Colorado, 3665 Discovery Drive, Boulder, CO 80303 (United States)

    2013-04-01

    We present the first published analysis of a solar occultation by Titan's atmosphere measured by the Ultraviolet Imaging Spectrograph on board Cassini. The data were measured during flyby T53 in 2009 April and correspond to latitudes between 21 Degree-Sign and 28 Degree-Sign south. The analysis utilizes the absorption of two solar emission lines (584 A and 630 A) in the ionization continuum of the N{sub 2} absorption cross section and solar emission lines around 1085 A where absorption is due to CH{sub 4}. The measured transmission at these wavelengths provides a direct estimate of the N{sub 2} and CH{sub 4} column densities along the line of sight from the spacecraft to the Sun, which we inverted to obtain the number densities. The high signal-to-noise ratio of the data allowed us to retrieve density profiles in the altitude range 1120-1400 km for nitrogen and 850-1300 km for methane. We find an N{sub 2} scale height of {approx}76 km and a temperature of {approx}153 K. Our results are in general agreement with those from previous work, although there are some differences. Particularly, our profiles agree, considering uncertainties, with the density profiles derived from the Voyager 1 Ultraviolet Spectrograph data, and with in situ measurements by the Ion Neutral Mass Spectrometer with revised calibration.

  3. A global perspective on atmospheric blocking using GPS radio occultation – one decade of observations

    Directory of Open Access Journals (Sweden)

    L. Brunner

    2017-12-01

    Full Text Available Atmospheric blocking represents a weather pattern where a stationary high-pressure system weakens or reverses the climatological westerly flow at mid-latitudes for up to several weeks. It is closely connected to strong anomalies in key atmospheric variables such as geopotential height, temperature, and humidity. Here we provide, for the first time, a comprehensive, global perspective on atmospheric blocking and related impacts by using an observation-based data set from Global Positioning System (GPS radio occultation (RO from 2006 to 2016. The main blocking regions in both hemispheres and seasonal variations are found to be represented well in RO data. The effect of blocking on vertically resolved temperature and humidity anomalies in the troposphere and lower stratosphere is investigated for blocking regions in the Northern and Southern hemispheres, respectively. We find a statistically significant correlation of blocking with positive temperature anomalies, exceeding 3 K in the troposphere, and a reversal above the tropopause with negative temperature anomalies below −3 K in the lower stratosphere. Specific humidity is positively correlated with temperature throughout the troposphere with larger anomalies revealed in the Southern Hemisphere. At the eastern and equatorward side of the investigated blocking regions, a band of tropospheric cold anomalies reveals advection of cold air by anticyclonic motion around blocking highs, which is less distinct in the Southern Hemisphere due to stronger zonal flow. We find GPS RO to be a promising new data set for blocking research that gives insight into the vertical atmospheric structure, especially in light of the expected increase in data coverage that future missions will provide.

  4. Migrating Polyarthritis as a Feature of Occult Malignancy: 2 Case Reports and a Review of the Literature

    Directory of Open Access Journals (Sweden)

    Geoffrey Alan Watson

    2015-01-01

    Full Text Available Malignant disease may be associated with a wide variety of musculoskeletal syndromes. Rarely the musculoskeletal system can be indirectly affected by paraneoplastic phenomena, such as carcinomatous polyarthritis (CP. The differential diagnosis for CP is broad and is often a diagnosis of exclusion. CP often presents similarly to other forms of inflammatory arthritis, and a detailed history and physical examination can often distinguish CP from other more common causes of polyarticular arthritis. However serological tests such as rheumatoid factor (RF and anti-citrullinated peptide (anti-CCP antibody positivity, while rare, can be misleading. Clinical awareness and suspicion are paramount in achieving an accurate diagnosis and early detection of an occult neoplasm is critical for prompt management and therapy. We report two cases presenting with this unique clinical phenotype associated with paraneoplastic polyarthropathy and review the literature.

  5. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  6. Voltammetric Determination of Thiodiglycolic Acid in Urine

    Czech Academy of Sciences Publication Activity Database

    Dlasková, Z.; Navrátil, Tomáš; Heyrovský, Michael; Pelclová, D.; Novotný, Ladislav

    2003-01-01

    Roč. 375, - (2003), s. 164-168 ISSN 1618-2642 Institutional research plan: CEZ:AV0Z4040901 Keywords : urine * thioglycolic acid * voltammetry Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.715, year: 2003

  7. Murine Automated Urine Sampler (MAUS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines planned development for a low-power, low-mass automated urine sample collection and preservation system for small mammals, capable of...

  8. Urine Albumin and Albumin/ Creatinine Ratio

    Science.gov (United States)

    ... it used? The urine albumin test or albumin/creatinine ratio (ACR) is used to screen people with chronic conditions, such as diabetes and high blood pressure ( hypertension ) that put them at an ...

  9. On-Demand Urine Analyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research program will develop a novel surface-enhanced Raman (SER) sensor that will perform real-time chemical analysis of urine. It...

  10. New method of investigation of urine microflora in mice after irradiation

    Directory of Open Access Journals (Sweden)

    Ivanov A.A.

    2013-12-01

    nated with one drop of urine, placed on surface Endo media, incubate in thermostat (37°C in during 1-2 days and numbers of positive crops (Esch. coli, Proteus, Enterococcus, were indicated. It was shown that after irradiation the numbers of positive probes increased. The test displayed that the method is easy, economic and demonstrative.

  11. The Cytotoxic Effect of Small and Large Molecules of PMF Fraction Extracted from Camel Urine on Cancer Cells

    KAUST Repository

    Khorshid, Faten; Emwas, Abdul-Hamid M.; Mahboub, Faiza

    2015-01-01

    Conclusion: This study, as well as previous ones, suggests that camel urine extracts (old and new PMF) may provide newer therapeutic alternatives to clinically manage cancer patients. However, further studies are needed to verify these positive preliminary results.

  12. Occurrence of riboflavinyl glucoside in rat urine

    International Nuclear Information System (INIS)

    Ohkawa, Hiroshi; Ohishi, Nobuko; Yagi, Kunio

    1983-01-01

    To investigate the metabolism of riboflavin, [2- 14 C]-riboflavin was administered orally to a rat. The urine pooled for 24 h after administration was fractionated by paper and silica gel thin layer chromatographies using various solvent systems. Among the radioactive metabolites, riboflavinyl glucoside was found along with 7-carboxy lumichrome and 8-carboxy lumichrome. The radioactivity of riboflavinyl glucoside comprised about 6 % of the total radioactivity excreted in the urine during 24 h. (author)

  13. Serial-omics characterization of equine urine.

    Directory of Open Access Journals (Sweden)

    Min Yuan

    Full Text Available Horse urine is easily collected and contains molecules readily measurable using mass spectrometry that can be used as biomarkers representative of health, disease or drug tampering. This study aimed at analyzing microliter levels of horse urine to purify, identify and quantify proteins, polar metabolites and non-polar lipids. Urine from a healthy 12 year old quarter horse mare on a diet of grass hay and vitamin/mineral supplements with limited pasture access was collected for serial-omics characterization. The urine was treated with methyl tert-butyl ether (MTBE and methanol to partition into three distinct layers for protein, non-polar lipid and polar metabolite content from a single liquid-liquid extraction and was repeated two times. Each layer was analyzed by high performance liquid chromatography-high resolution tandem mass spectrometry (LC-MS/MS to obtain protein sequence and relative protein levels as well as identify and quantify small polar metabolites and lipids. The results show 46 urine proteins, many related to normal kidney function, structural and circulatory proteins as well as 474 small polar metabolites but only 10 lipid molecules. Metabolites were mostly related to urea cycle and ammonia recycling as well as amino acid related pathways, plant diet specific molecules, etc. The few lipids represented triglycerides and phospholipids. These data show a complete mass spectrometry based-omics characterization of equine urine from a single 333 μL mid-stream urine aliquot. These omics data help serve as a baseline for healthy mare urine composition and the analyses can be used to monitor disease progression, health status, monitor drug use, etc.

  14. Impaired Urine Dilution Capability in HIV Stable Patients

    Directory of Open Access Journals (Sweden)

    Waldo H. Belloso

    2014-01-01

    Full Text Available Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle’s loop (TALH is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney’s ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz’ test. Material & Methods. Chaimowitz’ test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir.

  15. Radioimmunoassay of methaqualone in human urine compared with chromatographic methods

    International Nuclear Information System (INIS)

    Mule, S.J.; Kogan, M.; Jukofsky, D.

    1978-01-01

    The 125 I-radioimmunoassay for methaqualone in human urine was evaluated by a comparison with newly modified gas-liquid chromatographic and thin-layer chromatographic methods. The statistically significant sensitivity value for the radioimmunoassay was at 2 μg of methaqualone per liter of urine. The coefficient of variation was 2.88 -+ 0.16% intraassay. There was cross-reactivity only with metabolites of methaqualone, 4'-hydroxymethaqualone being twice as sensitively measured as methaqualone. There was complete agreement between results by radioimmunoassay and by gas-liquid chromatography in 96.7% of the samples analyzed. Only 1.2% of the radioimmunoassay values were false positives, and 2.1% false negatives (phi = 0.8917, P < 0.001). Comparisons between the thin-layer chromatographic data and the gas--liquid chromatographic or radioimmunoassay data showed less agreement because of the 50- to 200-fold higher sensitivity of the latter techniques. Gas--liquid chromatography therefore appears to represent the best reference method for the evaluation of the radioimmunoassay, which appears to be a very sensitive and reliable technique for detecting methaqualone and its metabolites in human urine

  16. Routine Urine Culture at the Time of Percutaneous Urinary Drainage: Does Every Patient Need One?

    International Nuclear Information System (INIS)

    Brody, L.A.; Brown, K.T.; Covey, A.M.; Brown, A.E.; Getrajdman, G.I.

    2006-01-01

    Purpose. To determine the clinical variables associated with bacteriuria in patients undergoing primary percutaneous antegrade urinary drainage procedures in order to predict the utility of routinely obtaining urine cultures at the time of the procedure. Methods. Between October 1995 and March 1998 urine cultures were prospectively obtained in all patients undergoing a primary percutaneous antegrade urinary drainage procedure. One hundred and eighty-seven patients underwent 264 procedures. Results were available in 252 cases. Culture results were correlated with clinical, laboratory, and demographic variables. Anaerobic cultures were not uniformly performed. Results. Urine cultures were positive in 24 of 252 (9.5%) cases. An indwelling or recently removed ipsilateral device (catheter or stent) and a history of previous cystectomy with urinary diversion were significant predictors of a positive culture. Patients without either of these predictors, and without clinical or laboratory evidence of infection, were rarely found to have positive cultures. Conclusion. The likelihood of a positive urine culture can be predicted on the basis of the aforementioned clinical variables. In the absence of these clinical indicators routine urine cultures are neither useful nor cost-effective

  17. Chemical Method of Urine Volume Measurement

    Science.gov (United States)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  18. Preventing Precipitation in the ISS Urine Processor

    Science.gov (United States)

    Muirhead, Dean; Carter, Layne; Williamson, Jill; Chambers, Antja

    2017-01-01

    The ISS Urine Processor Assembly (UPA) was initially designed to achieve 85% recovery of water from pretreated urine on ISS. Pretreated urine is comprised of crew urine treated with flush water, an oxidant (chromium trioxide), and an inorganic acid (sulfuric acid) to control microbial growth and inhibit precipitation. Unfortunately, initial operation of the UPA on ISS resulted in the precipitation of calcium sulfate at 85% recovery. This occurred because the calcium concentration in the crew urine was elevated in microgravity due to bone loss. The higher calcium concentration precipitated with sulfate from the pretreatment acid, resulting in a failure of the UPA due to the accumulation of solids in the Distillation Assembly. Since this failure, the UPA has been limited to a reduced recovery of water from urine to prevent calcium sulfate from reaching the solubility limit. NASA personnel have worked to identify a solution that would allow the UPA to return to a nominal recovery rate of 85%. This effort has culminated with the development of a pretreatment based on phosphoric acid instead of sulfuric acid. By eliminating the sulfate associated with the pretreatment, the brine can be concentrated to a much higher concentration before calcium sulfate reach the solubility limit. This paper summarizes the development of this pretreatment and the testing performed to verify its implementation on ISS.

  19. An update on purple urine bag syndrome

    Directory of Open Access Journals (Sweden)

    Hadano Y

    2012-08-01

    Full Text Available Yoshiro Hadano,1 Taro Shimizu,2 Shimon Takada,3 Toshiya Inoue,4 Sumire Sorano51Department of General Internal Medicine and Infectious Diseases, Rakuwakai Otowa Hospital, Yamashina-ku, Kyoto, Japan; 2Rollins School of Public Health, Emory University, Atlanta, GA, USA; 3Department of General Internal Medicine, Osaka City General Hospital, Miyakojima-ku, Osaka, Japan; 4Department of Emergency Medicine, Urasoe General Hospital, Urasoe-city, Okinawa, Japan; 5Kobe University School of Medicine, Kusunokicho, Chuoku, Kobe, JapanAbstract: Purple urine bag syndrome is characterized by the urinary drainage bag turning purple in patients on prolonged urinary catheterization, especially those in the bedridden state. It is associated with bacterial urinary tract infections caused by indigo-producing and indirubin-producing bacteria, usually affects women, and is associated with alkaline urine, constipation, and a high bacterial load in the urine. Almost all patients with purple urine bag syndrome are catheterized due to significant disability, and the urinary pH is 7.0 or more. In general, intensive treatment with antibiotics is not recommended. Purple urine bag syndrome per se almost always appears to be asymptomatic and harmless. However, caution is needed, because some cases have been reported to show progression to severe disease states, so further research into the morbidity and mortality of this infection is warranted.Keywords: purple urine, urinary catheterization, geriatrics, urinary tract infection

  20. Mutagens in urine of carbon electrode workers

    Energy Technology Data Exchange (ETDEWEB)

    Pasquini, R; Monarca, S; Sforzolini, G S; Conti, R; Fagioli, F

    1982-01-01

    Following previous work carried out in an Italian factory producing carbon electrodes and evaluating the occupational mutagenic-carcinogenic hazards, the authors studied the presence of mutagen metabolites in the urine of workers in the same factory who were exposed to petroleum coke and pitch and in the urine of a control group of unexposed workers. The urine samples were concentrated by absorption on XAD-2 columns and were tested using the Salmonella/microsome assay (strain TA98, TA100, TA1535, TA1538) with and without the addition of beta-glucuronidase and metabolizing system. The collection of urine samples was carried out twice, with an interval of 2 months; 'before working time', 'after working time', and also during Sunday. The results showed that urine samples collected 'before' occupational exposure (upon waking) or on Sunday revealed no mutagenic activity in either worker groups and that the urine samples collected after or during occupational exposure revealed high mutagenic activity in the exposed workers, with a statistically significant difference between the mean of the revertants/plate values for exposed and unexposed workers. On the basis of the previous and the present research, the authors suggest that application of the Salmonella/microsome test to work environments could offer useful and suitable tool for evaluating the health hazards due to mutagenic/carcinogenic substances from occupational exposure.

  1. Localization of occult breast lesions: mammographic findings in non infiltrating carcinoma; Localizacion de lesiones ocultas de mama: hallazgos mamograficos del carcinoma no infiltrante

    Energy Technology Data Exchange (ETDEWEB)

    Paul, L; Iribar, M; Vilarrasa, A; Lopez, M A; Hernandez, R; Carrasco, A [Departamento de Radiodiagnostico, Hospital Doce de Octubre, Madrid (Spain)

    1995-08-01

    A review was carried out of 169 biopsies of occult breast lesions, 32 of which were malignant. The radiological findings associated with in situ carcinomas were compared with those of malignant lesions in general. The signs that permit the detection of breast carcinoma in the earliest stages are described, and the positive predictive value of signs, such as a spicular form, clusters of microcalcifications, nodules and architectural disturbances, is discussed. Given the lack of specificity of these findings, many beginning lesions should be biopsied to ensure an early diagnosis of breast cancer. (Author)

  2. Recurring sets of recurring starspot occultations on exoplanet host Qatar-2

    Science.gov (United States)

    Močnik, T.; Southworth, J.; Hellier, C.

    2017-10-01

    We announce the detection of recurring sets of recurring starspot occultation events in the short-cadence K2 light curve of Qatar-2, a K dwarf star transited every 1.34 d by a hot Jupiter. In total, we detect 34 individual starspot occultation events, caused by five different starspots, occulted in up to five consecutive transits or after a full stellar rotation. The longest recurring set of recurring starspot occultations spans over three stellar rotations, setting a lower limit for the longest starspot lifetime of 58 d. Starspot analysis provided a robust stellar rotational period measurement of 18.0 ± 0.2 d and indicates that the system is aligned, having a sky-projected obliquity of 0° ± 8°. A pronounced rotational modulation in the light curve has a period of 18.2 ± 1.6 d, in agreement with the rotational period derived from the starspot occultations. We tentatively detect an ellipsoidal modulation in the phase curve, with a semi-amplitude of 18 ppm, but cannot exclude the possibility that this is the result of red noise or imperfect removal of the rotational modulation. We detect no transit-timing and transit-duration variations with upper limits of 15 s and 1 min, respectively. We also reject any additional transiting planets with transit depths above 280 ppm in the orbital period region 0.5-30 d.

  3. Retrieval of Electron Density Profile for KOMPSAT-5 GPS Radio Occultation

    Directory of Open Access Journals (Sweden)

    Woo-Kyoung Lee

    2007-12-01

    Full Text Available The AOPOD (Atmosphere Occultation and Precision Orbit Determination system, the secondary payload of KOMPSAT (KOrea Multi-Purpose SATellite-5 scheduled to be launched in 2010, shall provide GPS radio occultation data. In this paper, we simulated the GPS radio occultation characteristic of KOMPSAT-5 and retrieved electron density profiles using KROPS (KASI Radio Occultation Processing Software. The electron density retrieved from CHAMP (CHAllenging Minisatellite Payload GPS radio occultation data on June 20, 2004 was compared with IRI (International Reference Ionosphere - 2001, PLP (Planar Langmuir Probe, and ionosonde measurements. When the result was compared with ionosonde measurements, the discrepancies were 5 km on the F_2 peak height (hmF_2 and 3×10^{10} el/m^3 on the electron density of the F_2 peak height (NmF_2. By comparing with the Langmuir Probe measurements of CHAMP satellite (PLP, both agrees with 1.6×10^{11} el/m^3 at the height of 365.6 km.

  4. [Surgical Diagnosis and Treatment of Primary Hyperthyroidism Complicated with Occult Thyroid Carcinoma].

    Science.gov (United States)

    Wu, Xin; Yu, Jian-chun; Kang, Wei-ming; Ma, Zhi-qiang; Ye, Xin

    2015-08-01

    To evaluate the surgical diagnosis and treatment of primary hyperthyroidism complicated with occult thyroid carcinoma. Data of 51 cases of primary hyperthyroidism complicated with occult thyroid carcinoma admitted during January 2004 to November 2014 were analyzed retrospectively. The incidence of occult thyroid carcinoma was 5.03% in hyperthyroidism,and 47 cases (92.16%) were female. The preoperative diagnosis of all these 51 cases was primary hyperthyroidism and 11 cases were diagnosed thyroid carcinoma at the same time;25 cases were diagnosed thyroid carcinoma by frozen section and the remaining 26 cases were diagnosed by postoperative pathology. Finally,26 cases underwent subtotal thyroidectomy,4 cases underwent total thyroidectomy, and 21 cases underwent total thyroidectomy with lymphadenectomy. The tumor size ranged from 0.1 to 1.0 cm [mean:(0.63 ± 0.35) cm]. The lesions were less than or equal to 0.5 cm in 28 cases (54.9%). The follow-up lasted from 1 to 121 months [mean:(28.6 ± 22.7)months] in 43 patients,and all of them survived. Primary hyperthyroidism complicated with occult thyroid carcinoma is commonly found in female patients. Preoperative diagnosis is difficult. Ultrasound is the major examining method. Frozen section can increase the detection rate. The postoperative prognosis of hyperthyroidism complicated with occult thyroid carcinoma is satisfactory.

  5. [Prevalence of occult hepatitis B virus infection and its phylogenetic features among mother-teenager pairs].

    Science.gov (United States)

    Dong, Xiao-lian; Yao, Qing-qing; Wang, Xue-cai; Xu, Hai-tao; Wang, Xiao-li; Chen, Sheng-yu; Tang, Zhi-feng; Zheng, Ying-Jie

    2013-03-01

    Prevalence of occult hepatitis B virus (HBV) infection (OBI) was investigated in a paired mother-teenager population and HBV S gene variation including overt and occult HBV, was determined. A follow-up study based on an initial survey of 135 mother-teenager pairs was carried out through collection of questionnaires and blood samples HBsAg were detected by ELISA method, viral load by PCR amplification and HBV S gene by phylogenetic analysis. 102 pairs of subjects were followed-up. Blood samples from 94 mothers and 101 children were collected. OBI prevalence in mothers was 10.0% (6/60), significantly higher than 2.0% (2/101) in teenagers. Medians of viral load were 399.9 IU/ml and 247.6 IU/ml in overt and occult HBV strains, but without significant difference. 1 occult HBV strain belonged to genotype B with serotype adw while the other 7 were genotype C with serotype adr. 15 of the overt HBV strains belonged to genotype B with serotype adw and the other 8 were genotype C with serotype adr. Proportions of genotype-C strains were significantly higher in occult HBV strains than in overt HBV strains. OBI was seen in teenage-mother population.

  6. Disparities in the receipt of fecal occult blood test versus endoscopy among Filipino American immigrants.

    Science.gov (United States)

    Maxwell, Annette E; Danao, Leda L; Crespi, Catherine M; Antonio, Cynthia; Garcia, Gabriel M; Bastani, Roshan

    2008-08-01

    This report examines disparities associated with the type of colorectal screening test, fecal occult blood test versus endoscopy, within a particular racial/ethnic group, Filipino American immigrants. Between July 2005 and October 2006, Filipino Americans aged 50 to 75 years from 31 community organizations in Los Angeles completed a 15-minute survey in English (65%) or Filipino (35%). Of the 487 respondents included in this analysis, 257 (53%) had never received any type of colorectal cancer screening. Among the 230 subjects who had ever received a routine screening test, 78 had fecal occult blood test only (16% of the total sample), and 152 had endoscopy with or without fecal occult blood test (31% of the total sample). After controlling for access to care and key demographic variables in a multivariate analysis, only two characteristics distinguished between respondents who had fecal occult blood test only versus those who had endoscopy: acculturation, assessed by percent lifetime in the United States and language of interview, and income. Our data suggest a two-tier system, fecal occult blood test for less acculturated Filipino Americans with lower income versus endoscopy for Filipino immigrants with higher levels of acculturation and income. The disparity persists after adjusting for access to care. Instead of treating minority groups as monolithic, differences within groups need to be examined so that interventions can be appropriately targeted.

  7. Optimization of the occulter for the Solar Orbiter/METIS coronagraph

    Science.gov (United States)

    Landini, Federico; Vivès, Sébastien; Romoli, Marco; Guillon, Christophe; Pancrazzi, Maurizio; Escolle, Clement; Focardi, Mauro; Antonucci, Ester; Fineschi, Silvano; Naletto, Giampiero; Nicolini, Gianalfredo; Nicolosi, Piergiorgio; Spadaro, Daniele

    2012-09-01

    METIS (Multi Element Telescope for Imaging and Spectroscopy investigation), selected to fly aboard the Solar Orbiter ESA/NASA mission, is conceived to perform imaging (in visible, UV and EUV) and spectroscopy (in EUV) of the solar corona, by means of an integrated instrument suite located on a single optical bench and sharing the same aperture on the satellite heat shield. As every coronagraph, METIS is highly demanding in terms of stray light suppression. Coronagraphs history teaches that a particular attention must be dedicated to the occulter optimization. The METIS occulting system is of particular interest due to its innovative concept. In order to meet the strict thermal requirements of Solar Orbiter, METIS optical design has been optimized by moving the entrance pupil at the level of the external occulter on the S/C thermal shield, thus reducing the size of the external aperture. The scheme is based on an inverted external-occulter (IEO). The IEO consists of a circular aperture on the Solar Orbiter thermal shield. A spherical mirror rejects back the disk-light through the IEO. A breadboard of the occulting assembly (BOA) has been manufactured in order to perform stray light tests in front of two solar simulators (in Marseille, France and in Torino, Italy). A first measurement campaign has been carried on at the Laboratoire d'Astrophysique de Marseille. In this paper we describe the BOA design, the laboratory set-up and the preliminary results.

  8. Multisite Direct Determination of the Potential for Environmental Contamination of Urine Samples Used for Diagnosis of Sexually Transmitted Infections.

    Science.gov (United States)

    Andersson, Patiyan; Tong, Steven Y C; Lilliebridge, Rachael A; Brenner, Nicole C; Martin, Louise M; Spencer, Emma; Delima, Jennifer; Singh, Gurmeet; McCann, Frances; Hudson, Carolyn; Johns, Tracy; Giffard, Philip M

    2014-09-01

    The detection of a sexually transmitted infection (STI) agent in a urine specimen from a young child is regarded as an indicator of sexual contact. False positives may conceivably arise from the transfer of environmental contaminants in clinic toilet or bathroom facilities into urine specimens. The potential for contamination of urine specimens with environmental STI nucleic acid was tested empirically in the male and female toilets or bathrooms at 10 Northern Territory (Australia) clinics, on 7 separate occasions at each. At each of the 140 experiments, environmental contamination with Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis nucleic acid contamination was determined by swabbing 10 locations, and urine collection was simulated 5 times, using a (1) synthetic urine surrogate and (2) a standardized finger contamination procedure. The most contaminated toilets and bathrooms were in remote Indigenous communities. No contamination was found in the Northern Territory Government Sexual Assault Referral Centre clinics, and intermediate levels of contamination were found in sexual health clinics and in clinics in regional urban centres. The frequency of surrogate urine sample contamination was low but non-zero. For example, 4 of 558 of the urine surrogate specimens from remote clinics were STI positive. This is by far the largest study addressing the potential environmental contamination of urine samples with STI agents. Positive STI tests arising from environmental contamination of urine specimens cannot be ruled out. The results emphasize that urine specimens from young children taken for STI testing should be obtained by trained staff in clean environments, and duplicate specimens should be obtained if possible. © The Author 2013. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society.

  9. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    Science.gov (United States)

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  10. The Return of Congenital Rickets, Are We Missing Occult Cases?

    Science.gov (United States)

    Elidrissy, Abdelwahab T H

    2016-09-01

    Congenital rickets is the term given to fetus born with clinical features of rickets, but those born with biochemical evidence of rickets without obvious clinical features still can be considered occult congenital rickets. Some of the affected babies with this disease have the intrauterine rachitic environment, but a calcium trans-placental pump prevents the fetus from having clinical features of rickets. They may present with hypocalcemia few days after birth or later with more florid features of rickets. Congenital rickets cases born with florid features reported over the last 40 years are few and can be divided into two groups. The first due to severe maternal osteomalacia in which their bones were so decalcified to have enough calcium to be pumped to their fetus. Another group in which newborn babies were hypocalcemic due to other maternal diseases as malabsorption, celiac disease, pre-eclampsia, and prematurity. All inherited rickets cases per se, or as part of other syndromes can be considered congenital rickets. Most cases seen in our region are due to maternal vitamin D deficiency with symptoms becoming obvious when the infants are breastfed, or may present with hypocalcemic convulsions or craniotabes. This is a review of congenital rickets with the aim of shedding light on this potentially acute disease that needs more attention and awareness in the neonatal period to avoid rare serious complications as cardiomyopathy or myelofibrosis and the complications of hypocalcemic convulsions. Congenital rickets cases seen simulate a tip of an ice-burg and its prevention is an important issue, especially with the tremendous urbanization with tall buildings living in sun-deprived flats as the commonest type of residence leading to the increasing incidence of maternal osteomalacia and rickets.

  11. Clues to occult cancer in patients with ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Suk Jae Kim

    Full Text Available BACKGROUND: We hypothesized that hidden malignancy could be detected in patients with cryptogenic stroke without active cancer when they showed the distinctive characteristics of cancer-related stroke. METHODS AND FINDINGS: Among 2,562 consecutive patients with acute ischemic stroke, patients with cryptogenic stroke were analyzed and categorized into two groups according to the presence of active cancer: cryptogenic stroke with active cancer (cancer-related stroke, CA-stroke group and without active cancer (CR-stroke group. Patients with active lung cancer without stroke were also recruited for comparison purposes (CA-control. Clinical factors, lesion patterns on diffusion-weighted MRI (DWI, and laboratory findings were analyzed among groups. A total of 348 patients with cryptogenic stroke were enrolled in this study. Among them, 71 (20.4% patients had active cancer at the time of stroke. The D-dimer levels were significantly higher in patients with CA-stroke than those with CR-stroke or CA-control (both p<0.001. Regarding lesion patterns, patients with CA-stroke mostly had multiple lesions in multiple vascular territories, while more than 80% of patients with CR-stroke had single/multiple lesions in a single vascular territory (P<0.001. D-dimer levels (OR 1.11 per 1 µg/mL increase; 95% CI 1.06-1.15; P<0.001 and DWI lesion patterns (OR 7.13; 95% CI 3.42-14.87; P<0.001 were independently associated with CA-stroke. Workup for hidden malignancy was performed during hospitalization in 10 patients who showed elevated D-dimer levels and multiple infarcts involving multiple vascular territories but had no known cancer, and it revealed hidden malignancies in all the patients. CONCLUSION: Patients with CA-stroke have distinctive D-dimer levels and lesion patterns. These characteristics can serve as clues to occult cancer in patients with cryptogenic stroke.

  12. Clinical presentations and MRI findings of angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Oyama, Hirofumi; Iwakoshi, Takayasu

    1994-01-01

    Various clinical features as well as MRI findings of AOVM (angiographically occult vascular malformation) were studied. Amongst out patients, since January 1988, there have been 30 cases of symptomatic AOVM (20 males, 10 females) including 4 cases with multiple lesions. The age ranged from 3 to 60 years of age, with a mean of 33.4 years. The locations of symptomatic lesions were in the cerebral hemisphere (15), the thalamus (4), the brain stem (8) and in the cerebellum (3). The initial presentations of these 30 cases were either by hemorrhage (18), convulsive seizure (9) or by progressive neurological deficits (3). The initial presentation was not related to the patient's age and the size of the lesion, but apparently related to the location of AOVM. Most of the lesions in the cerebral hemisphere presented seizures, but all of the lesions in the thalamus, the brain stem and the cerebellum disclosed hemorrhage as an initial presentation. In fact it was noticed that brain stem lesions tend to cause repetitive hemorrhage in a relatively short period. AOVM lesions were clearly visualized with T2-weighted MRI images, consisting of high intensity cores with surrounding low intensity rims. Most of the symptomatic lesions were partially enhanced by Gd-DTPA with varied intensity. Dynamic changes in size and enhancement pattern on MRI were occasionally seen, usually accompanied with episodes such as hemorrhage or neurological deterioration. Although AOVMs were angiographically negative some strands indicating draining veins were observed on MRI in several cases. In contrast, none of the nonsymptomatic lesions (22 lesions) demonstrated enhancement effects with Gd-DTPA. (author)

  13. TWENTY-FIVE SUBARCSECOND BINARIES DISCOVERED BY LUNAR OCCULTATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Richichi, A. [National Astronomical Research Institute of Thailand, 191 Siriphanich Bldg., Huay Kaew Rd., Suthep, Muang, Chiang Mai 50200 (Thailand); Fors, O. [Departament Astronomia i Meteorologia and Institut de Ciencies del Cosmos (ICC), Universitat de Barcelona (UB/IEEC), Marti i Franques 1, E-08028 Barcelona (Spain); Cusano, F. [INAF-Osservatorio Astronomico di Bologna, Via Ranzani 1, I-40127 Bologna (Italy); Moerchen, M., E-mail: andrea4work@gmail.com [European Southern Observatory, Casilla 19001, Santiago 19 (Chile)

    2013-09-15

    We report on 25 subarcsecond binaries, detected for the first time by means of lunar occultations in the near-infrared (near-IR) as part of a long-term program using the ISAAC instrument at the ESO Very Large Telescope. The primaries have magnitudes in the range K = 3.8-10.4, and the companions in the range K = 6.4-12.1. The magnitude differences have a median value of 2.8, with the largest being 5.4. The projected separations are in the range 6-748 mas and with a median of 18 mas, or about three times less than the diffraction limit of the telescope. Among our binary detections are a pre-main-sequence star and an enigmatic Mira-like variable previously suspected to have a companion. Additionally, we quote an accurate first-time near-IR detection of a previously known wider binary. We discuss our findings on an individual basis as far as made possible by the available literature, and we examine them from a statistical point of view. We derive a typical frequency of binarity among field stars of Almost-Equal-To 10%, in the resolution and sensitivity range afforded by the technique ( Almost-Equal-To 0.''003 to Almost-Equal-To 0.''5, and K Almost-Equal-To 12 mag, respectively). This is in line with previous results using the same technique but we point out interesting differences that we can trace up to sensitivity, time sampling, and average distance of the targets. Finally, we discuss the prospects for further follow-up studies.

  14. Waves in Saturn's rings probed by radio occultation

    International Nuclear Information System (INIS)

    Rosen, P.A.

    1989-01-01

    Thirty wave features, observed in 3.6 and 13 cm-wavelength optical depth profiles of Saturn's rings obtained by Voyager 1 radio occultation, are analyzed individually and comparatively. Many are the signature of spiral density waves and bending waves excited by gravitational resonances with Saturn's satellites. A new technique for locating waveform extrema, which fits a sinusoid to each half cycle of wave data, quantifies the wavelength variation across a feature. Fitting dispersion models to the derived wavelengths provides new estimates of ambient surface mass density σ in each wave region. For fourteen weak density waves in Ring A, modelling of the waveform near resonance with linear density wave theory gives independent estimates of σ, as well as reliable estimates of resonance location. Measurements of wave amplitude damping give an upper bound for ring thickness 2H, where H is the ring scale height. In the wave regions studied, Rings A, B, and C have 30 approx-lt σ approx-lt 70, σ approx-gt 65, and σ ∼ 1 g/cm 2 , respectively. Mass loading estimates from waveform modelling are 20 to 40% larger than dispersion-derived values, suggesting accumulation of mass in the wave regions. The average offset of derived wave location from theoretical resonance is about 1 km. Model waveforms of overlapping waves excited by the satellites Janus and Epimethenus agree well with observed morphologies in the linear region near resonance. In Ring C, dispersion analysis indicates that the most prominent wave feature, previously unidentified, is a one-armed spiral wave

  15. The potential of at-home prediction of the formation of urolithiasis by simple multi-frequency electrical conductivity of the urine and the comparison of its performance with urine ion-related indices, color and specific gravity.

    Science.gov (United States)

    Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S

    2016-04-01

    It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.

  16. Lowest-order average effect of turbulence on atmospheric profiles derived from radio occultation

    International Nuclear Information System (INIS)

    Eshleman, V.R.; Haugstad, B.S.

    1977-01-01

    Turbulence in planetary atmospheres and ionospheres causes changes in angles of refraction of radio waves used in occultation experiments. Atmospheric temperature and pressure profiles, and ionospheric electron concentration profiles, derived from radio occultation measurements of Doppler frequency contain errors due to such angular offsets. The lowest-order average errors are derived from a geometrical-optics treatment of the radio-wave phase advance caused by the addition of uniform turbulence to an initially homogeneous medium. It is concluded that the average profile errors are small and that precise Doppler frequency measurements at two or more wavelengths could be used to help determine characteristics of the turbulence, as well as accuracy limits and possible correction terms for the profiles. However, a more detailed study of both frequency and intensity characteristics in radio and optical occultation measurements of turbulent planetary atmospheres and ionospheres is required to realize the full potential of such measurements

  17. An integration time adaptive control method for atmospheric composition detection of occultation

    Science.gov (United States)

    Ding, Lin; Hou, Shuai; Yu, Fei; Liu, Cheng; Li, Chao; Zhe, Lin

    2018-01-01

    When sun is used as the light source for atmospheric composition detection, it is necessary to image sun for accurate identification and stable tracking. In the course of 180 second of the occultation, the magnitude of sun light intensity through the atmosphere changes greatly. It is nearly 1100 times illumination change between the maximum atmospheric and the minimum atmospheric. And the process of light change is so severe that 2.9 times per second of light change can be reached. Therefore, it is difficult to control the integration time of sun image camera. In this paper, a novel adaptive integration time control method for occultation is presented. In this method, with the distribution of gray value in the image as the reference variable, and the concepts of speed integral PID control, the integration time adaptive control problem of high frequency imaging. The large dynamic range integration time automatic control in the occultation can be achieved.

  18. Magnetic field orientations in Saturn's upper ionosphere inferred from Voyager radio occultations

    Science.gov (United States)

    Hinson, D. P.

    1984-01-01

    The radio scintillations observed during occultations of Voyagers 1 and 2 by Saturn are analyzed to determine the morphology of plasma irregularities and hence the magnetic field orientation in Saturn's upper atmosphere. The measurement techniques, the weak scattering theory, and the method used to relate the observed radio scintillations to physical properties of the ionospheric irregularities are briefly described. Results on the spatial characteristics of the irregularities are presented, and the magnetic field orientation in Saturn's ionosphere is inferred. Although the occultation measurements generally confirm the accuracy of the Saturnian magnetic field model of Connerney et al. (1982), it is found that a small adjustment of the coefficients in that model's zonal harmonic expansion would remove the discrepancy between the model predictions and the measurements. A strategy for obtaining improved measurements of Saturn's magnetic field from radio occultation observations of scintillations and Faraday rotation using an orbiting spacecraft is briefly discussed.

  19. Helios-1 Faraday rotation experiment - Results and interpretations of the solar occultations in 1975

    Science.gov (United States)

    Volland, H.; Bird, M. K.; Levy, G. S.; Stelzried, C. T.; Seidel, B. L.

    1977-01-01

    The first of two solar occultations of the satellite Helios-1 in 1975 occurred in April when the satellite's ray path approached the west limb of the sun to a minimum distance of 1.63 solar radii. The second occultation took place in late August/early September when Helios-1 was totally eclipsed by the photosphere. Measurements of the polarization angle of the linearly polarized telemetry signal were performed with automatic tracking polarimeters at the 64 m Goldstone Tracking Station in California and also at the 100 m radio telescope in Effelsberg, West Germany. The coronal Faraday rotation as a function of the solar offset for both occultations is shown in graphs. The theoretical significance of the observations is investigated.

  20. Do X-ray-occult fractures play a role in chronic pain following a whiplash injury?

    DEFF Research Database (Denmark)

    Hertzum-Larsen, Rasmus; Petersen, Henrik; Kasch, Helge

    2014-01-01

    symptoms following an MVA was invited to have a cervical SPECT shortly post injury and again 6 months later. Associations between occult fractures and pain levels at baseline, 6 and 12 months of follow-up were analyzed. Eighty-eight patients had baseline SPECT performed at median 15 days (range 3-28) post......Whiplash trauma in motor vehicle accidents (MVA) may involve various painful soft tissue damages, but weeks/months later a minority of victims still suffers from various long-lasting and disabling symptoms, whiplash-associated disorders (WAD). The etiology is currently unknown, but X......-ray-occult fractures may be one cause in some cases. The purpose of this prospective study was to examine the association between occult fractures, as seen on bone single photon emission computed tomography (SPECT), with neck-, head- and arm pain. An inception cohort of 107 patients presenting with acute whiplash...

  1. The role of human papilloma virus and p16 in occult primary of the head and neck: a comprehensive review of the literature.

    Science.gov (United States)

    Fotopoulos, George; Pavlidis, Nicholas

    2015-02-01

    Cancer of unknown primary of the head and neck is a challenging entity for the oncologist. The role of human papilloma virus/p16 in carcinogenesis and in prognosis is well established in certain HNSCC especially in that of the oropharynx. In the case of occult primary of the head and neck the role of HPV/p16 positivity is not well defined regarding prognosis and localization of the primary. An independent review of PubMed and ScienceDirect database was performed up to May 2014 using combinations of terms such as "occult primary of the head and neck", "CUP of the head and neck" "metastatic cervical squamous cell carcinoma of unknown primary", "HPV" and "HPV and head and neck cancer". Literature review shows a strong association between HPV/p16 positivity and primary location in the oropharynx in patients with CUP of the head and neck as well as a better clinical outcome. HPV positivity and p16 overexpression could be used as surrogate markers in the search of the primary site of patients with CUP of the head and neck therefore maybe guiding treatment decisions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Leukocyte counts in urine reflect the risk of concomitant sepsis in bacteriuric infants: A retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Harper Marvin B

    2007-06-01

    Full Text Available Abstract Background When urine infections are missed in febrile young infants with normal urinalysis, clinicians may worry about the risk – hitherto unverified – of concomitant invasion of blood and cerebrospinal fluid by uropathogens. In this study, we determine the extent of this risk. Methods In a retrospective cohort study of febrile 0–89 day old infants evaluated for sepsis in an urban academic pediatric emergency department (1993–1999, we estimated rates of bacteriuric sepsis (urinary tract infections complicated by sepsis after stratifying infants by urine leukocyte counts higher, or lower than 10 cells/hpf. We compared the global accuracy of leukocytes in urine, leukocytes in peripheral blood, body temperature, and age for predicting bacteruric sepsis. The global accuracy of each test was estimated by calculating the area under its receiver operating characteristic curve (AUC. Chi-square and Fisher exact tests compared count data. Medians for data not normally distributed were compared by the Kruskal-Wallis test. Results Two thousand two hundred forty-nine young infants had a normal screening dipstick. None of these developed bacteremia or meningitis despite positive urine culture in 41 (1.8%. Of 1516 additional urine specimens sent for formal urinalysis, 1279 had 0–9 leukocytes/hpf. Urine pathogens were isolated less commonly (6% vs. 76% and at lower concentrations in infants with few, compared to many urine leukocytes. Urine leukocytes (AUC: 0.94 were the most accurate predictors of bacteruric sepsis. Infants with urinary leukocytes Conclusion In young infants evaluated for fever, leukocytes in urine reflect the likelihood of bacteriuric sepsis. Infants with urinary tract infections missed because of few leukocytes in urine are at relatively low risk of invasive bacterial sepsis by pathogens isolated from urine.

  3. The effect of sleep on nocturnal urine output

    DEFF Research Database (Denmark)

    Kamperis, Konstantinos; Hagstrøm, Søren; Rittig, Søren

    2005-01-01

    sleep and the sequence was randomized. During these nights with sleep deprivation, participants were in lying position in a dimly lit room and physical activities, food and fluid intake were not allowed. Smoking was not allowed throughout the entire experimental protocol. Determinations of electrolytes...... sleep related physiological mechanisms into consideration. In the present study we report that acute sleep deprivation has a dramatic effect on the volume of nocturnal urine production in both genders although the effect is more pronounced in males. Natriuresis and kaliuresis were observed on nights...

  4. Estimation of uptake from censored urine excretion data

    International Nuclear Information System (INIS)

    Marsh, J.W.; Birchall, A.

    1994-01-01

    The estimation of radionuclide uptake often involves consideration of measurements of urine excretion which may include some values reported as below the limit of detection (LOD). Data sets which contain below LOD data as well as positive results are known as censored data sets. A simple method which uses the information contained in censored data to estimate uptake is described. A Monte Carlo technique has been used to investigate the accuracy and the efficiency of the method using simulated data sets with increasing numbers of LOD data points. (author)

  5. Occult Pelvic Lymph Node Involvement in Bladder Cancer: Implications for Definitive Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, Benjamin; Baumann, Brian C.; He, Jiwei; Tucker, Kai; Bekelman, Justin; Deville, Curtiland; Vapiwala, Neha [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vaughn, David; Keefe, Stephen M. [Department of Medical Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Guzzo, Thomas; Malkowicz, S. Bruce [Department of Urology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2014-03-01

    Purpose: To inform radiation treatment planning for clinically staged, node-negative bladder cancer patients by identifying clinical factors associated with the presence and location of occult pathologic pelvic lymph nodes. Methods and Materials: The records of patients with clinically staged T1-T4N0 urothelial carcinoma of the bladder undergoing radical cystectomy and pelvic lymphadenectomy at a single institution were reviewed. Logistic regression was used to evaluate associations between preoperative clinical variables and occult pathologic pelvic or common iliac lymph nodes. Percentages of patient with involved lymph node regions entirely encompassed within whole bladder (perivesicular nodal region), small pelvic (perivesicular, obturator, internal iliac, and external iliac nodal regions), and extended pelvic clinical target volume (CTV) (small pelvic CTV plus common iliac regions) were calculated. Results: Among 315 eligible patients, 81 (26%) were found to have involved pelvic lymph nodes at the time of surgery, with 38 (12%) having involved common iliac lymph nodes. Risk of occult pathologically involved lymph nodes did not vary with clinical T stage. On multivariate analysis, the presence of lymphovascular invasion (LVI) on preoperative biopsy was significantly associated with occult pelvic nodal involvement (odds ratio 3.740, 95% confidence interval 1.865-7.499, P<.001) and marginally associated with occult common iliac nodal involvement (odds ratio 2.307, 95% confidence interval 0.978-5.441, P=.056). The percentages of patients with involved lymph node regions entirely encompassed by whole bladder, small pelvic, and extended pelvic CTVs varied with clinical risk factors, ranging from 85.4%, 95.1%, and 100% in non-muscle-invasive patients to 44.7%, 71.1%, and 94.8% in patients with muscle-invasive disease and biopsy LVI. Conclusions: Occult pelvic lymph node rates are substantial for all clinical subgroups, especially patients with LVI on biopsy. Extended

  6. Assessment of Radiometer Calibration with GPS Radio Occultation for the MiRaTA CubeSat Mission

    Science.gov (United States)

    Marinan, Anne D.; Cahoy, Kerri L.; Bishop, Rebecca L.; Lui, Susan S.; Bardeen, James R.; Mulligan, Tamitha; Blackwell, William J.; Leslie, R. Vincent; Osaretin, Idahosa; Shields, Michael

    2017-01-01

    The Microwave Radiometer Technology Acceleration (MiRaTA) is a 3U CubeSat mission sponsored by the NASA Earth Science Technology Office (ESTO). The science payload on MiRaTA consists of a tri-band microwave radiometer and Global Positioning System (GPS) radio occultation (GPSRO) sensor. The microwave radiometer takes measurements of all-weather temperature (V-band, 50-57 GHz), water vapor (G-band, 175-191 GHz), and cloud ice (G-band, 205 GHz) to provide observations used to improve weather forecasting. The Aerospace Corporation's GPSRO experiment, called the Compact TEC (Total Electron Content) and Atmospheric GPS Sensor (CTAGS), measures profiles of temperature and pressure in the upper troposphere/lower stratosphere (∼20 km) and electron density in the ionosphere (over 100 km). The MiRaTA mission will validate new technologies in both passive microwave radiometry and GPS radio occultation: (1) new ultra-compact and low-power technology for multi-channel and multi-band passive microwave radiometers, (2) the application of a commercial off the shelf (COTS) GPS receiver and custom patch antenna array technology to obtain neutral atmospheric GPSRO retrieval from a nanosatellite, and (3) a new approach to spaceborne microwave radiometer calibration using adjacent GPSRO measurements. In this paper, we focus on objective (3), developing operational models to meet a mission goal of 100 concurrent radiometer and GPSRO measurements, and estimating the temperature measurement precision for the CTAGS instrument based on thermal noise. Based on an analysis of thermal noise of the CTAGS instrument, the expected temperature retrieval precision is between 0.17 K and 1.4 K, which supports the improvement of radiometric calibration to 0.25 K. PMID:28828144

  7. The role of cow urine in the oviposition site preference of culicine and Anopheles mosquitoes

    Directory of Open Access Journals (Sweden)

    Kweka Eliningaya J

    2011-09-01

    Full Text Available Abstract Background Chemical and behavioural ecology of mosquitoes plays an important role in the development of chemical cue based vector control. To date, studies available have focused on evaluating mosquito attractants and repellents of synthetic and human origins. This study, however, was aimed at seasonal evaluation of the efficiency of cow urine in producing oviposition cues to Anopheles gambiae s.l. and Culex quinquefasciatus in both laboratory and field conditions. Methods Oviposition response evaluation in laboratory conditions was carried out in mosquito rearing cages. The oviposition substrates were located in parallel or in diagonal positions inside the cage. Urine evaluation against gravid females of An. arabiensis and Cx. quinquefasciatus was carried out at Day 1, Day 3 and Day 7. Five millilitres (mls of cow urine was added to oviposition substrate while de-chlorinated water was used as a control. In field experiments, 500 mls of cow urine was added in artificial habitats with 2500 mls of de-chlorinated water and 2 kgs of soil. The experiment was monitored for thirty consecutive days, eggs were collected daily from the habitats at 7.00 hrs. Data analysis was performed using parametric and non-parametric tests for treatments and controls while attraction of the oviposition substrate in each species was presented using Oviposition Activity Index (OAI. Results The OAI was positive with ageing of cattle urine in culicine species in both laboratory and field experiments. The OAI for anopheline species was positive with fresh urine. The OAI during the rainy season was positive for all species tested while in the dry season the OAI for culicine spp and Anopheles gambiae s.l., changed with time from positive to negative values. Based on linear model analysis, seasons and treatments had a significant effect on the number of eggs laid in habitats, even though the number of days had no effect. Conclusion Oviposition substrates treated with

  8. Relationship between urine albumin and endothelin in children with anaphylactoid purpura

    International Nuclear Information System (INIS)

    Duan Yongqiang; Chen Nianfa

    2009-01-01

    To study the function of urine albumin and endothelin (ET-1) in the occurrence and progress of ansphylactoid purura (HSP) and anaphylaxis purura nephritis (HSPN) in children, the serum level of ET-1 and urine albumin excretion rate in 29 children with HSP and 21 normal controls was detected by RIA and salicylic acid nephelometry respectively. The results showed that the content of urine albumin in 24 hours in HSP group has no significant difference compared with that of control group (P>0.05) , but the corresponding content in HSPN group has significant difference compared with that of control and HSP group (P<0.01). The serum ET-1 in HSP group has significant difference compared with control group (P<0.05), and the corresponding content in HSPN group has significant difference compared with control group and HSP group (P<0.01, P<0.05). The levels of urine albumin of 24 hours and serum ET-1 in HSPN group after treatment were decreased obviously compared with those before treatment (P<0.01). The content of urine albumin of 24 hours was positively correlated with serum levels of ET-1. The ET-1 participated the formation of HSP and HSPN, and was related to the occurrence and progress of urine albumin. (authors)

  9. [Identification of Methamphetamine Abuse and Selegiline Use: Chiral Analysis of Methamphetamine and Amphetamine in Urine].

    Science.gov (United States)

    Xiang, P; Bu, J; Qiao, Z; Zhuo, X Y; Wu, H J; Shen, M

    2017-12-01

    To study the content variation of selegiline and its metabolites in urine, and based on actual cases, to explore the feasibility for the identification of methamphetamine abuse and selegiline use by chiral analysis. The urine samples were tested by chiral separation and LC-MS/MS method using CHIROBIOTIC™ V2 chiral liquid chromatography column. The chiral analysis of methamphetamine and amphetamine were performed on the urine samples from volunteers of selegiline use and drug addicts whom suspected taking selegiline. After 5 mg oral administration, the positive test time of selegiline in urine was less than 7 h. The mass concentrations of R(-)-methamphetamine and R(-)-amphetamine in urine peaked at 7 h which were 0.86 μg/mL and 0.18 μg/mL and couldn't be detected after 80 h and 168 h, respectively. The sources of methamphetamine and amphetamine in the urine from the drug addicts whom suspected taking selegiline were analysed successfully by present method. The chiral analysis of methamphetamine and amphetamine, and the determination of selegiline's metabolites can be used to distinguish methamphetamine abuse from selegiline use. Copyright© by the Editorial Department of Journal of Forensic Medicine

  10. New Markers: Urine Xanthine Oxidase and Myeloperoxidase in the Early Detection of Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    Pınar Ciragil

    2014-01-01

    Full Text Available Objectives. The aim of this study was to evaluate if xanthine oxidase and myeloperoxidase levels quantitation method may alternate routine culture method, which takes more time in the diagnosis of urinary tract infections. Material and Methods. Five hundred and forty-nine outpatients who had admitted to Clinic Microbiology Laboratory were included in the study. The microorganisms were identified by using VITEK System. The urine specimens that were negative from the quantitative urine culture were used as controls. The activities of MPO and XO in spot urine were measured by spectrophotometric method. Results. Through the urine cultures, 167 bacteria were isolated from 163 urine specimens; 386 cultures yielded no bacterial growth. E. coli was the most frequent pathogen. In infection with E. coli both XO and MPO levels were increased the most. The sensitivity, specificity, positive predictive value, and negative predictive value for XO were 100%, 100%, 100%, and 100%, respectively. These values for MPO were 87%, 100%, 100%, and 94%, respectively. Conclusion. These data obtained suggest that urine XO and MPO levels may be new markers in the early detection of UTI.

  11. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  12. Prognostic value of a quantitative analysis of lipoarabinomannan in urine from patients with HIV-associated tuberculosis.

    Directory of Open Access Journals (Sweden)

    Andrew D Kerkhoff

    Full Text Available Detection of the mycobacterial cell wall antigen lipoarabinomannan (LAM in urine can be used to diagnose HIV-associated tuberculosis (TB using a qualitative (positive/negative read-out. However, it is not known whether the quantity of LAM present in urine provides additional prognostic information.Consecutively recruited adult outpatients initiating antiretroviral therapy (ART in South Africa were investigated for TB regardless of clinical symptoms using sputum smear microscopy and liquid culture (reference standard. Urine samples were tested using the Clearview TB-ELISA for LAM and the Xpert MTB/RIF assay. The ELISA optical densities (OD were used as a quantitative assessment of urine LAM. Among 514 patients with complete sputum and urine LAM OD results, culture-confirmed TB was diagnosed in 84 patients. Twenty-three (27.3% were LAM-positive with a median LAM OD of 0.68 (IQR 0.16-2.43; range, 0.10-3.29 and 61 (72.6% were LAM negative (LAM OD <0.1 above background. Higher LAM ODs were associated with a range of prognostic indices, including lower CD4 cell counts, lower haemoglobin levels, higher blood neutrophil counts and higher mycobacterial load as assessed using both sputum and urine samples. The median LAM OD among patients who died was more than 6.8-fold higher than that of patients who remained alive at 3 months (P<0.001. The small number of deaths, however, precluded adequate assessment of mortality risk stratified according to urine LAM OD.In patients with HIV-associated TB, concentrations of LAM in urine were strongly associated with a range of poor prognostic characteristics known to be associated with mortality risk. Urine LAM assays with a semi-quantitative (negative vs. low-positive vs. high-positive read-out may have improved clinical utility over assays with a simple binary result.

  13. Prenatal lignan exposures, pregnancy urine estrogen profiles and birth outcomes

    International Nuclear Information System (INIS)

    Tang, Rong; Chen, Minjian; Zhou, Kun; Chen, Daozhen; Yu, Jing; Hu, Weiyue; Song, Ling; Hang, Bo; Wang, Xinru; Xia, Yankai

    2015-01-01

    During pregnancy, human exposure to endogenous estrogens and xenoestrogens (such as lignans) may comprehensively impact the gestational maintenance and fetal growth. We measured the concentrations of 5 lignans and the profile of 13 estrogen metabolites (EMs) in the urine samples of 328 pregnant women and examined their associations with birth outcomes. We found significantly positive associations between gestational age and urinary matairesinol (MAT), enterodiol (END) and enterolactone (ENL), as well as 16-hydroxylation pathway EMs. There were consistently positive relationships between END and the 16-hydroxylation pathway EMs. The positive relationships of MAT, END and ENL exposures with the length of gestation were mainly in the low exposure strata of the levels of these EMs. This study reveals that MAT, END and ENL as well as 16-hydroxylation pathway EMs are associated with birth outcomes, and that there are interactive relationships between lignans and 16-hydroxylation pathway EMs with birth outcomes. - Highlights: • We examined relations between prenatal lignan exposures and birth outcomes. • We examined relations between pregnancy urine estrogen profiles and birth outcomes. • MAT, END and ENL are associated with birth outcomes. • 16-hydroxylation pathway EMs are associated with birth outcomes. • There are interactive relationships between ligans and EMs with birth outcomes. - Prenatal lignan exposures and EM levels were interactively related to birth outcomes

  14. Fecal occult blood test for colorectal cancer screening: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    diagnostic studies was examined according to the 'GRADE Working Group criteria' for grading quality of evidence and strength of recommendations for diagnostic tests and strategies. SINGLE-TEST STUDIES: There is limited direct/indirect evidence that iFOBT has sensitivity/specificity superior to that of unrehydrated gFOBT for CRC detection: sensitivity for gFOBT:13% and 25%pooled iFOBT sensitivity:81%There is evidence that iFOBT and gFOBT have lower sensitivities for adenoma detection than for CRC detection: sensitivity for rehydrated gFOBT22%pooled iFOBT sensitivity28% REPEATED-TEST STUDIES: No trials have examined CRC mortality outcomes after repeated testing of iFOBT. Two RCTs from the United Kingdom and Denmark showed significant reduction in CRC mortality using unrehydrated gFOBT biennially Relative risk reductions of 13% (UK trial) and 16% (Danish trial); absolute difference of 0.1% (UK trial) and 0.2% (Danish trial).No significant reduction in overall mortalityInterval cancers (CRC that develop in the intervals between routine screening) UNITED KINGDOM TRIAL: 236 CRCs detected by positive test, 236 interval CRCs after negative testDANISH TRIAL: 120 CRCs detected by positive test, 146 interval CRCs after negative testUnrehydrated gFOBT has low sensitivity for CRC detection (45% in the UK trial and 54% in the Danish trial). true positive rate50% (United Kingdom and Danish RCTs)false positive rate5%-10%true negative rate90%-95% (from observational studies as RCTs did not report specificity)false negative rate50%ES Table 1:Guaiac FOBT - GRADE Quality of Evidence for InterventionsOutcomeDesignQualityConsistencyDirectnessOverall QualityCRCMortalityRCTDanishN = 137,485United KingdomN = 152,850No seriouslimitationsYes (RR reduction in 2 trials13% and 16%; absolutedifference 0.1% and 0.2%respectively).Age rangeDanish and UnitedKingdom study 45-75yearsHighCRC indicates colorectal cancer; FOBT, fecal occult blood test; GRADE, Grading of Recommendations Assessment, Development and

  15. Detection of an occult transclival cerebrospinal fluid fistula by CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schick, B.; Brors, D.; Draf, W. [Department of Ear, Nose and Throat Diseases, Head, Neck and Facial Plastic Surgery, Marburg Univ. (Germany); Goedecke, A. [Department of Radiology, Academic Teaching Hospital, Fulda (Germany); Prescher, A. [Department of Anatomy and Embryology, University Medical School, RWTH, Aachen (Germany)

    1998-12-01

    We describe an unusual occult transclival cerebrospinal fluid (CSF) fistula to the sphenoid sinus demonstrated by MRI. CT was performed because of a posterior cerebral infarct caused by cardiac arrhythmia. Axial sections showed fluid in the sphenoid sinus. High-resolution scans revealed a bony defect 3 mm in diameter of the posterior wall of the sphenoid sinus, and MRI showed a transclival CSF fistula. This occult lesion was confirmed by surgery and duraplasty was successfully performed via an endonasal approach. (orig.) With 3 figs., 19 refs.

  16. Occult Invasive Lobular Carcinoma of Breast Detected by Stomach Metastasis: A Case Report

    International Nuclear Information System (INIS)

    KIm, So Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Yoon, Jung Hyun

    2012-01-01

    Gastric metastasis from primary breast cancer is a rare phenomenon that is more prevalent in the invasive lobular type of breast cancer. We describe a very rare case of occult invasive lobular cancer of the breast detected by the initial presentation of gastric metastasis in a patient without a history of breast cancer. A 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) which showed increased FDG uptake in the stomach, abdominal mesentery and the right breast, and played pivotal roles in the detection of occult primary breast cancer and a diagnosis of gastric metastasis as an ancillary method for obtaining histological results and immunohistochemical stains.

  17. Occult injuries of the femoral neck in osteoporosis of aged patients

    International Nuclear Information System (INIS)

    Reichelt, H.G.

    1985-01-01

    Fractures of the femoral neck in elderly patients are often a complication in osteoporosis. Diagnosis of fractures with displacement and compression of fragments is quite easy. The negative radiograph in old patients complaining of hip pain is generally considered a characteristic feature of presensile osteoporotic pain. Clinical examples present patients with hip pain caused by occult injuries of the femoral neck. They should be regarded as imminent fractures and adequately treated. Bone scan is very helpful in the early detection of such occult osteroporotic injuries. (orig.) [de

  18. Occult Invasive Lobular Carcinoma of Breast Detected by Stomach Metastasis: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    KIm, So Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Yoon, Jung Hyun [Dept. of Radiology, Bundang CHA general Hospital, CHA University College of Medicine, Seongnam (Korea, Republic of)

    2012-02-15

    Gastric metastasis from primary breast cancer is a rare phenomenon that is more prevalent in the invasive lobular type of breast cancer. We describe a very rare case of occult invasive lobular cancer of the breast detected by the initial presentation of gastric metastasis in a patient without a history of breast cancer. A 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) which showed increased FDG uptake in the stomach, abdominal mesentery and the right breast, and played pivotal roles in the detection of occult primary breast cancer and a diagnosis of gastric metastasis as an ancillary method for obtaining histological results and immunohistochemical stains.

  19. A Comparison of 4- and 24-Hour Urine Samples for the Diagnosis of Proteinuria in Pregnancy

    Directory of Open Access Journals (Sweden)

    Afsane Amirabi

    2011-09-01

    Full Text Available Background: Preeclampsia is a serious complication of pregnancy, and it is vital to diagnosis the condition as early as possible. Proteinuria is an important symptom of preeclampsia, and repeated urine analysis to screen for the condition is part of the standard antenatal care. The purpose of this study was to determine the correlation between 4- and 24-hour urine total protein values to examine whether the 4-hour urine samples could be used for the diagnosis of proteinuria in hypertensive disorders of pregnancy. Methods: A cross-sectional study was performed on 110 pregnant (after gestational week 20 of pregnancy patients who were hypertensive (blood pressure ≥140/90 mmHg and had proteinuria as defined by positive urinary protein of at least 1+ in dipstick. Patients' urine samples were collected over 24 hours; the first 4 hours were collected separately from the next 20-hours. Patients, who did not collect the 24-hour urine, were excluded from the study. One hundred patients met the criteria, and were included in the study. The urine volume, total protein and creatinine levels of 4- and 24-hours samples were measured. The correlation between 4-hour and 24-hour samples was examined using Pearson correlation test. Results: Of the 100 patients, 42 had no proteinuria, 44 had mild proteinuria, and 14 had severe proteinuria. The urine protein values of 4-hour samples correlated with those of the 24-hours samples for patients with mild and severe forms of the disease (P<0.001, r=0.86. Conclusion: This study showed there was a correlation between 4-hour and 24-hour urine proteins. The finding indicates that a random 4-hour sample might be used for the initial assessment of proteinuria

  20. Analysis of Urobilinogen and Urine Bilirubin for Intra-Abdominal Injury in Blunt Trauma Patients

    Directory of Open Access Journals (Sweden)

    Gorchynski, Julie

    2009-05-01

    Full Text Available OBJECTIVE: To determine the point prevalence of urine bilirubin, urine hemoglobin and urobilinogen in blunt trauma patients, and to evaluate its utility as a screening tool for intra-abdominal injury.METHODS: Data analysis of 986 consecutive trauma patients of which 698 were adult blunt trauma patients. Five-hundred sixteen subjects had a urinalysis and a CT scan of the abdomen/pelvis or exploratory laparotomy. We reviewed initial urinalysis results from trauma patients in the emergency department (ED for the presence of urine hemoglobin, uroblinogen and urine bilirubin. Computed tomography (CT scan results and operative reports were reviewed from the trauma registry for evidence of liver laceration, spleen laceration, bowel or mesenteric injuries.RESULTS: There were 73 injuries and 57/516 patients (11% with intra-abdominal injury. Urinalysis was positive for urobilinogen in 28/516 (5.4% patients, urine bilirubin in 15/516 (2.9% patients and urine hemoglobin in 313/516 (61% patients. Nineteen/forty-seven (4% subjects had liver lacerations, 28/56 (5% splenic lacerations, and 15/5 (3% bowel or mesenteric injury. Comparing the proportion of patients that had urobilinogen detected in the group with and without intra-abdominal injury, 8/28 (29% subjects with urobilinogen, 5/15 (33% subjects with bilirubin and 47/313 (15% subjects with urine hemoglobin were found to have liver lacerations, spleen lacerations, or bowel/mesenteric injuries. Preexisting liver or biliary conditions were not statistically associated with elevation of urine bilirubin, urine hemoglobin or urobilinogen on initial urinalysis after blunt abdominal trauma. Point prevalence for urobilinogen, urine bilirubin and urine hemoglobin are 5.43% (28/516, 2.91% (15/516 and 60.7% (313/516 respectively.CONCLUSIONS: The utility of the initial routine urinalysis in the ED for adult blunt abdominal trauma patients should not be used as a screening tool for the evaluation of intra

  1. Water vapour and methane coupling in the stratosphere observed using SCIAMACHY solar occultation measurements

    Directory of Open Access Journals (Sweden)

    S. Noël

    2018-04-01

    Full Text Available An improved stratospheric water vapour data set has been retrieved from SCIAMACHY/ENVISAT solar occultation measurements. It is similar to that successfully applied to methane and carbon dioxide. There is now a consistent set of data products for the three constituents covering the altitudes 17–45 km, the latitude range between about 50 and 70° N, and the period August 2002 to April 2012. The new water vapour concentration profiles agree with collocated results from ACE-FTS and MLS/Aura to within  ∼  5 %. A significant positive linear change in water vapour for the time 2003–2011 is observed at lower stratospheric altitudes with a value of about 0.015 ± 0.008 ppmv year−1 around 17 km. Between 30 and 37 km the changes become significantly negative (about −0.01 ± 0.008 ppmv year−1; all errors are 2σ values. The combined analysis of the SCIAMACHY methane and water vapour time series shows the expected anti-correlation between stratospheric methane and water vapour and a clear temporal variation related to the Quasi-Biennial Oscillation (QBO. Above about 20 km most of the additional water vapour is attributed to the oxidation of methane. In addition short-term fluctuations and longer-term variations on a timescale of 5–6 years are observed. The SCIAMACHY data confirm that at lower altitudes the amount of water vapour and methane are transported from the tropics to higher latitudes via the shallow branch of the Brewer–Dobson circulation.

  2. Occult inflammatory breast cancer: review of clinical, mammographic, US and pathologic signs

    International Nuclear Information System (INIS)

    Cumo, Francesca; Gaioni, Maria Berenice; Bonetti, Franco; Manfrin, Erminia; Remo, Andrea; Pattaro, Christian; Policlinico G.B. Rossi, Verona

    2005-01-01

    Purpose: To examine the clinical, radiologic and pathologic findings of occult inflammatory breast cancer (OIBC) in order to identify features useful for diagnosis. Materials and methods: We retrospectively reviewed the records of 19 women with OIBC observed at our Department between 1992 and 2001. We analysed the clinical history, mammographic, ultrasonographic, and pathologic findings and investigated overall survival (OS), prognostic variables and radio-pathologic correlations. Results: The most common mammographic findings were: diffusely density (52.63%), trabecular thickening (42.1%), mass (36.84%). The most common US findings were axillary lymphadenopathy (68,75%), skin thickening (43.75%) and mass (56.25%). At least one inflammatory sign was found in 14 women (74%) at mammography (subcutaneous thickening, trabecular thickening, diffuse increase of density) or at US (subcutaneous thickening, diffuse increase in echogenicity due to oedema, lymph vessel dilatation). Estrogen receptors (ER) were present in 63.2% and Progesterone receptors (PgR) in 36.8%. Significant prognostic variables were ER and Ki 67. Conclusions: The typical radiological pattern of clinical inflammatory breast carcinoma is less frequently present in OIBC; nevertheless the radiologist must pay attention because frequently OIBC presents just one radiological sign and this should be enough for a diagnostic suspicion. Moreover, the absence of clinical and radiological inflammatory signs does not exclude inflammatory breasts cancer because OIBC can manifest at imaging as a mass or isolated calcification. ER and PgR are positive in a high percentage of patients and confirm that OIBC has a better prognosis that clinical inflammatory breast cancer [it

  3. Occult Amebic Liver Abscess as Cause of Extensive Inferior Vena Cava and Hepatic Vein Thrombosis.

    Science.gov (United States)

    Martin, Leslie; Burute, Nishigandha; Haider, Ehsan; Serrano, Pablo E; O'Shea, Timothy; Siegal, Deborah

    2017-10-01

    The most common extraintestinal complication of Entamoeba histolytica is amebic liver abscess (ALA). Hepatic vein and inferior vena cava (IVC) thrombosis are rare but well-documented complications of ALA, typically attributed to mechanical compression and inflammation associated with a large abscess. We present a case of a previously healthy 43-year-old Canadian man presenting with constitutional symptoms and right upper quadrant abdominal pain. He was found to have thrombophlebitis of the IVC, accessory right hepatic vein, and bilateral iliac veins. Extensive investigations for thrombophilia were negative. Magnetic resonance imaging of the liver demonstrated a 3.2-cm focal area of parenchymal abnormality that was reported as presumptive hepatocellular carcinoma, and a 1.9-cm lesion in the caudate lobe with diffusion restriction and peripheral rim enhancement. Despite multiple biopsy attempts, a histopathological diagnosis was not achieved. Abdominal pain and fever 4 months later prompted repeat ultrasound demonstrating a 10.4- × 12.0-cm rim-enhancing fluid attenuation lesion felt to represent a liver abscess. Thick dark "chocolate brown" drainage from the lesion and positive serology for E. histolytica confirmed the diagnosis of ALA acquired from a previous trip to Cuba. The patient was started on treatment with metronidazole and paromomycin and repeat abdominal ultrasound demonstrated resolution of the abscess. This case is the first to demonstrate extensive IVC thrombosis secondary to a relatively small occult ALA and emphasizes the thrombogenic potential of ALA. Amebic infection should be considered as a rare cause of IVC thrombosis in the correct clinical context.

  4. Harmonic analysis of the ionospheric electron densities retrieved from FORMOSAT-3/COSMIC radio occultation measurements

    Science.gov (United States)

    Masoumi, S.; Safari, A.; Sharifi, M.; Sam Khaniani, A.

    2011-12-01

    In order to investigate regular variations of the ionosphere, the least-squares harmonic estimation is applied to the time series of ionospheric electron densities in the region of Iran derived from about five years of Global Positioning System Radio Occultation (GPS RO) observations by FORMOSAT-3/COSMIC satellites. Although the obtained results are slightly different from the expected ones due to the low horizontal resolution of RO measurements, high vertical resolution of the observations enables us to detect not only the Total Electron Content (TEC) variations, but also periodic patterns of electron densities in different altitudes of the ionosphere. Dominant diurnal and annual signals, together with their Fourier series decompositions, and also periods close to 27 days are obtained, which is consistent with the previous analyses on TEC. In the equatorial anomaly band, the annual component is weaker than its Fourier decomposition periods. In particular, the semiannual period dominates the annual component, which is probably due to the effect of geomagnetic field. By the investigation of the frequencies at different local times, the semiannual signal is more significant than the annual one in the daytime, while the annual frequency is dominant at night. By the detection of the phases of the components, it is revealed that the annual signal has its maximum in summer at high altitudes, and in winter at lower altitudes. This suggests the effect of neutral compositions in the lower atmosphere. Further, the semiannual component peaks around equinox during the day, while its maximum mostly occurs in solstice at night. Since RO measurements can be used to derive TEC along the signal path between a GPS satellite and a receiver, study on the potentiality of using these observations for the prediction of electron densities and its application to the ionospheric correction of the single frequency receivers is suggested.

  5. Evaluating the lower-tropospheric COSMIC GPS radio occultation sounding quality over the Arctic

    Science.gov (United States)

    Yu, Xiao; Xie, Feiqin; Ao, Chi O.

    2018-04-01

    Lower-tropospheric moisture and temperature measurements are crucial for understanding weather prediction and climate change. Global Positioning System radio occultation (GPS RO) has been demonstrated as a high-quality observation technique with high vertical resolution and sub-kelvin temperature precision from the upper troposphere to the stratosphere. In the tropical lower troposphere, particularly the lowest 2 km, the quality of RO retrievals is known to be degraded and is a topic of active research. However, it is not clear whether similar problems exist at high latitudes, particularly over the Arctic, which is characterized by smooth ocean surface and often negligible moisture in the atmosphere. In this study, 3-year (2008-2010) GPS RO soundings from COSMIC (Constellation Observing System for Meteorology, Ionosphere, and Climate) over the Arctic (65-90° N) show uniform spatial sampling with average penetration depth within 300 m above the ocean surface. Over 70 % of RO soundings penetrate deep into the lowest 300 m of the troposphere in all non-summer seasons. However, the fraction of such deeply penetrating profiles reduces to only about 50-60 % in summer, when near-surface moisture and its variation increase. Both structural and parametric uncertainties of GPS RO soundings were also analyzed. The structural uncertainty (due to different data processing approaches) is estimated to be within ˜ 0.07 % in refractivity, ˜ 0.72 K in temperature, and ˜ 0.05 g kg-1 in specific humidity below 10 km, which is derived by comparing RO retrievals from two independent data processing centers. The parametric uncertainty (internal uncertainty of RO sounding) is quantified by comparing GPS RO with near-coincident radiosonde and European Centre for Medium-Range Weather Forecasts (ECMWF) ERA-Interim profiles. A systematic negative bias up to ˜ 1 % in refractivity below 2 km is only seen in the summer, which confirms the moisture impact on GPS RO quality.

  6. A Climate Benchmark of Upper Air Temperature Observations from GNSS Radio Occultation

    Science.gov (United States)

    Ao, C. O.; Mannucci, A. J.; Leroy, S. S.; Verkhoglyadova, O. P.

    2017-12-01

    GPS (Global Positioning System), or more generally Global Navigation Satellite System (GNSS), radio occultation (RO) is a remote sensing technique that produces highly accurate temperature in the upper troposphere and lower stratosphere across the globe with fine vertical resolution. Its fundamental measurement is the time delay of the microwave signal as it travels from a GNSS satellite to the receiver in low Earth orbit. With a relatively simple physical retrieval, the uncertainty in the derived temperature can be traced rigorously through the retrieval chain back to the raw measurements. The high absolute accuracy of RO allows these observations to be assimilated without bias correction in numerical weather prediction models and provides an anchor for assimilating other types of observations. The high accuracy, coupled with long-term stability, makes RO valuable in detecting decadal temperature trends. In this presentation, we will summarize the current state of RO observations and show temperature trends derived from 15 years of RO data in the upper troposphere and lower stratosphere. We will discuss our recent efforts in developing retrieval algorithms that are more tailored towards climate applications. Despite the relatively robust "self-calibrating" nature of RO observations, disparity in receiver hardware and software may introduce subtle differences that need to be carefully addressed. While the historic RO data record came from relatively homogeneous hardware based largely on NASA/JPL design (e.g., CHAMP and COSMIC), the future data will likely be comprised of a diverse set of observations from Europe, China, and various commercial data providers. In addition, the use of non-GPS navigation systems will become more prevalent. We will discuss the challenges involved in establishing a long-term RO climate data record from a suite of research and operational weather satellites with changes in instrumentation and coverage.

  7. The Two-Tier Fecal Occult Blood Test: Cost-Effective Screening

    Directory of Open Access Journals (Sweden)

    Andrew J Rae

    1994-01-01

    Full Text Available The two-tier test represents a strategy combining HO Sensa and Hemeselect fecal occult blood tests (FOBTs with the aim of greater specificity and consequent economic advantages. If patients register a positive result on any HO Sensa guaiac test, they are once again tested by a hemoglobin-specific Hemeselect test. This concept was applied to a multicentre study involving persons 40 years or older. One component of the study enrolled 573 high risk patients while the second arm recruited an additional 1301 patients (52% asymptomatic/48% symptomatic stratified according to personal history and symptoms. The two-tier test produced fewer false positives than traditional tests in both groups evaluated in the study. In the high risk group, specificity (88.7% for two-tier versus 80.6% for Hemoccult and 69.5% for HO Sensa was higher and false positive rates were lower (11.3% for two-tier versus 19.5% for Hemoccultand 30.5% for HO Sensa for the two-tier test versus Hemoccult and HO Sensa FOBTs (95% CI for all colorectal cancers [CRCs] and polyps greater than 1 cm, α=0.05 . No significant differences in sensitivity were observed between tests in the same group. Also, in the high risk group, benefits of the two-tier test outweighed the costs. Due to the small number of cancers and polyps in the second arm of the study, presentation of data is meant to be descriptive and representative of trends in a ‘normal’ population. Nevertheless, specificity of the two-tier test was higher (96.8% for two-tier versus 87.2% for Hemoccult and 69.5% for HO Sensa and false positive rate lower (3.2% for two-tier versus 12.8% for Hemoccult and 22.3% for HO Sensa than either the Hemoccult or HO Sensa FOBT (95% CI for all CRCs and polyps greater than 1 cm. This initial study, focusing on the cost-benefit relationship of increased specificity, represents a new way of economically evaluating existing FOBTs.

  8. Determination of uranium isotopes in urine

    International Nuclear Information System (INIS)

    Lellis, I.R.; Silva, D.V.F.M. Rey; Taddei, M.H.T.

    2017-01-01

    Variable concentrations of uranium occur naturally in waters, plant products and soils. Small amounts of this element are routinely incorporated by man. Occupationally exposed individuals (IOEs) are subject to the incorporation of higher amounts of uranium into their work routines. The effects on human health resulting from the incorporation of uranium in environmental doses are not very well established and are currently recognized as of little relevance. The incorporation resulting from occupational activities, where higher doses can be found, represents a health risk resulting from chemical damages to the kidneys. Considering that uranium is eliminated from the human body through urine and feces, and that the concentration in the urine can be obtained by means of radiochemical analyzes, this can be considered an efficient indirect method to verify the incorporation of this element. In the work the isotopes of 234 U, 235 U and 238 U were analyzed in urine samples of IOEs and the rate of uranium present in them was verified

  9. Measurement of menadione in urine by HPLC.

    Science.gov (United States)

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. Urine alkalization facilitates uric acid excretion

    Science.gov (United States)

    2010-01-01

    Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet) and others composed of less protein but vegetable-fruit rich food materials (alkali diet). Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+) and anions (Cl-,SO42-,PO4-) necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai) were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-]), indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body. PMID:20955624

  11. Urine alkalization facilitates uric acid excretion

    Directory of Open Access Journals (Sweden)

    Seyama Issei

    2010-10-01

    Full Text Available Abstract Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet and others composed of less protein but vegetable-fruit rich food materials (alkali diet. Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+ and anions (Cl-,SO42-,PO4- necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-], indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body.

  12. Sequential analysis of selected actinides in urine

    International Nuclear Information System (INIS)

    Kramer, G.H.

    1980-07-01

    The monitoring of personnel by urinalysis for suspected contamination by actinides necessitated the development and implementation of an analytical scheme that will separate and identify alpha emitting radionuclides of these elements. The present work deals with Pu, Am, and Th. These elements are separated from an ashed urine sample by means of coprecipitation and ion exchange techniques. The final analysis is carried out by electroplating the actinides and counting in a α-spectrometer. Mean recoveries of these elements from urine are: Pu 64%, Am 74% and Th 69%. (auth)

  13. Radioimmunoscintigraphy of recurrent, metastatic, or occult colorectal cancer with technetium 99m-labeled totally human monoclonal antibody 88BV59: results of pivotal, phase III multicenter studies.

    Science.gov (United States)

    Serafini, A N; Klein, J L; Wolff, B G; Baum, R; Chetanneau, A; Pecking, A; Fischman, A J; Hoover, H C; Wynant, G E; Subramanian, R; Goroff, D K; Hanna, M G

    1998-05-01

    To assess the performance and potential clinical impact of a totally human monoclonal antibody, 88BV59 (HumaSPECT) (INTRACEL, Corp, Rockville, MD), in 202 assessable presurgical patients with recurrent, metastatic, or occult colorectal cancer. 88BV59, labeled with technetium Tc 99m (99mTc) (HumaSPECT-Tc), was injected intravenously, and planar and single photon emission tomography (SPECT) images were obtained 14 to 20 hours postinjection. Surgical and pathologic verification of tumor were used as the standard against which the performance of HumaSPECT-Tc imaging and computed tomography (CT) analysis were evaluated. All patients entered onto the recurrent disease study had at least one tumor site defined on CT. The sensitivity of HumaSPECT-Tc in those CT-positive patients was 87%. The specificity of HumaSPECT-Tc was 57% compared with 17% for CT and the difference was statistically significant (P HAHA) response (90 ng/mL) at 9 weeks postinfusion was observed. HumaSPECT-Tc can provide important and accurate information about the presence and location of disease in patients with a high clinical suspicion of metastatic or recurrent colorectal cancer and either positive (known disease) or negative (occult disease) CT scans.

  14. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control.

    Science.gov (United States)

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-09-18

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure's positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a

  15. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control

    International Nuclear Information System (INIS)

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-01-01

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a

  16. The Accuracy of the Sysmex UF-1000i in Urine Bacterial Detection Compared With the Standard Urine Analysis and Culture.

    Science.gov (United States)

    Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri

    2017-11-01

    - Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.

  17. Cysteinyl leukotrienes in the urine of patients with liver diseases.

    Science.gov (United States)

    Uemura, M; Buchholz, U; Kojima, H; Keppler, A; Hafkemeyer, P; Fukui, H; Tsujii, T; Keppler, D

    1994-10-01

    The significance of cysteinyl leukotrienes was investigated in patients with liver diseases by measurements of leukotriene E4 and N-acetyl-leukotriene E4 in urine. A marked increase of renal cysteinyl leukotriene excretion was observed in patients with cirrhosis without and with ascites, intrahepatic cholestasis, and obstructive jaundice as compared with healthy subjects (leukotriene E4: means 82, 264, 221 and 142 versus 40 nmol/mol creatinine, respectively; N-acetyl-leukotriene E4: means 25, 64, 61 and 47 versus 13 nmol/mol creatinine, respectively). The urinary concentration of leukotriene E4 was positively correlated with the one of N-acetyl-leukotriene E4 (r = 0.81, p jaundice, the excretion of leukotriene E4 plus N-acetyl-leukotriene E4 was positively correlated with total serum bilirubin. In patients with cirrhosis and in those with obstructive jaundice, the cysteinyl leukotrienes in urine were negatively correlated with creatinine clearance. The elevated renal excretion of cysteinyl leukotrienes decreased after biliary drainage in patients with obstructive jaundice. These data support the concept that increased urinary excretion of cysteinyl leukotrienes in patients with cirrhosis is due to a reduced functional liver mass and that in patients with cholestasis it is mainly due to an impaired elimination into the biliary tract that results in a diversion to renal excretion.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Treatment for occult hepatocellular carcinoma: does it offer survival advantages over symptom-driven treatment?

    Science.gov (United States)

    Kim, Kwang Min; Kim, Jiyu; Sinn, Dong Hyun; Kim, Hye Seung; Kim, Kyunga; Kang, Wonseok; Gwak, Geum-Youn; Paik, Yong-Han; Choi, Moon Seok; Lee, Joon Hyeok; Koh, Kwang Cheol; Paik, Seung Woon

    2018-04-03

    In order to claim a benefit of screen-based diagnosis for asymptomatic individuals, treatment of occult disease needs to offer survival advantages compared to the treatment of symptomatic disease, yet information on this issue is scarce with regard to hepatocellular carcinoma (HCC) screening. A total of 3353 treatment-naïve, consecutive, newly diagnosed HCC patients [age: 57.9 ± 10.3, male: 2,689 (80.2%), hepatitis B virus: 2555 (76.2%)], diagnosed between 2010 and 2013 were analyzed. Data on the mode of detection was prospectively collected at the time of HCC diagnosis and was used to group patients into occult or symptomatic cases. Overall, 643 (19.2%) patients were symptomatic cases. The proportion of patients undergoing resection, radiofrequency ablation or transplantation were lower in symptomatic cases than occult cases (20.8 vs. 56.2%, p offered a survival benefit to patients over symptomatic cases. These data support screening practices for asymptomatic individuals to diagnose occult HCC.

  19. First Ionospheric Results From the MAVEN Radio Occultation Science Experiment (ROSE)

    Science.gov (United States)

    Withers, Paul; Felici, M.; Mendillo, M.; Moore, L.; Narvaez, C.; Vogt, M. F.; Jakosky, B. M.

    2018-05-01

    Radio occultation observations of the ionosphere of Mars can span the full vertical extent of the ionosphere, in contrast to in situ measurements that rarely sample the main region of the ionosphere. However, most existing radio occultation electron density profiles from Mars were acquired without clear context for the solar forcing or magnetospheric conditions, which presents challenges for the interpretation of these profiles. Here we present 48 ionospheric electron density profiles acquired by the Mars Atmosphere and Volatile EvolutioN mission (MAVEN) Radio Occultation Science Experiment (ROSE) from 5 July 2016 to 27 June 2017 at solar zenith angles of 54° to 101°. Latitude coverage is excellent, and comprehensive context for the interpretation of these profiles is provided by other MAVEN instruments. The profiles show a 9-km increase in ionospheric peak altitude in January 2017 that is associated with a lower atmospheric dust storm, variations in electron densities in the M1 layer that cannot be explained by variations in the solar soft X-ray flux, and topside electron densities that are larger in strongly magnetized regions than in weakly magnetized regions. MAVEN Radio Occultation Science Experiment electron density profiles are publicly available on the NASA Planetary Data System.

  20. Lunar occultation of the Galactic center at 2.2 microns

    NARCIS (Netherlands)

    Adams, D. J.; Becklin, E. E.; Jameson, R. F.; Longmore, A. J.; Sandqvist, Aa.; Valentijn, E.

    1988-01-01

    Results of the lunar occultation of IRS 16 on 1986 September 11 are reported. Sixty percent of the observed flux in a 6arcsec.5 beam comes from four discrete sources. Three sources are unresolved pointlike objects (<0arcsec.05) and are assumed to be individual stars. The fourth object is well

  1. Post traumatic urinary extravasation in occult urinary obstruction: Report of three cases

    Directory of Open Access Journals (Sweden)

    Jyoti Bothra

    2016-01-01

    Full Text Available Urinary extravastion after blunt abdominal trauma is seen often and generally treated conservatively. However a blunt renal trauma causing huge amount of extravasations and symptoms disproportionate to the severity of trauma should alarm the surgeon towards an underlying occult renal pathology usually an obstruction. In this case series, we share three such experiences and their management.

  2. Detection of occult hepatitis B virus among chronic hepatitis C patients

    African Journals Online (AJOL)

    Background: Concurrent infections with hepatitis B virus (HBV) and hepatitis C virus (HCV) are increasingly recognized in patients with chronic hepatitis. In Egypt, the last decade showed a remarkable decline in HBV infection associated with remarkable rise in HCV infection. The probable impact of occult HBV in patients ...

  3. Aplastic crisis in occult hereditary spherocytosis caused by human parvovirus (HPV B19).

    Science.gov (United States)

    Rappaport, E S; Quick, G; Ransom, D; Helbert, B; Frankel, L S

    1989-02-01

    We have reported a case of aplastic crisis occurring in an 11-year-old black boy with occult hereditary spherocytosis. An etiologic diagnosis of human parvovirus (HPV) B19 infection was confirmed serologically. The Coulter Model S + IV proved useful for both diagnosis and treatment monitoring through serial histograms. The relationship of HPV infection and aplastic crisis is discussed.

  4. Clinical relevance of occult tumor cells in lymph nodes from gastric cancer patients.

    NARCIS (Netherlands)

    Doekhie, F.S.; Mesker, W.H.; Krieken, J.H.J.M. van; Kok, N.F.; Hartgrink, H.H.; Kranenbarg, E.K.; Putter, H.; Kuppen, P.J.; Tanke, H.J.; Tollenaar, R.A.E.M.; Velde, C.J. van de

    2005-01-01

    The current method for staging in gastric cancer is not sufficient as even after a complete primary tumor resection, patients with node-negative gastric cancer suffer from disease recurrence. In this study, the relation between disease recurrence and the presence of occult tumor cells (OTC) in lymph

  5. Design and Verification of External Occulters for Direct Imaging of Extrasolar Planets

    Science.gov (United States)

    Cady, Eric

    2011-01-01

    An occulter is an optical element which is placed in front of the telescope to block most of the light from a star before it reaches the optics inside, without blocking the planet.In our case, we use two spacecraft ying in formation: First has its edge shaped to cancel the starlight Second is the telescope which images the star and planet

  6. Inappropriate use of the faecal occult blood test in a university hospital in the Netherlands

    NARCIS (Netherlands)

    van Rijn, Anne F.; Stroobants, An K.; Deutekom, Marije; Lauppe, Corinne; Sturk, Auguste; Bossuyt, Patrick M. M.; Fockens, Paul; Dekker, Evelien

    2012-01-01

    Objectives Although all international guidelines state that there is no indication to perform a faecal occult blood test (FOBT) in symptomatic patients, we believe the test is frequently used as a diagnostic test. The objective of this study was to investigate whether the current guidelines for FOBT

  7. Tropical cyclone cloud‐top height and vertical temperature structure detection using GPS radio occultation measurements

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Ho, Shu‐Peng; Randel, William

    2013-01-01

    The accurate determination of tropical cyclone (TC) cloud-top height and its vertical thermal structure using the GPS radio occultation (RO) technique is demonstrated in this study. Cloud-top heights are determined by using the bending angle anomaly and the temperature anomaly profiles during...

  8. Indeling occulte tumorcellen in de lymfklieren bij patiënten met darmkanker onvoldoende betrouwbaar

    NARCIS (Netherlands)

    van der Zaag, E. S.; Welling, L.; Peters, H. M.; van de Vijver, M. J.; Bemelman, W. A.; Buskens, C. J.

    2011-01-01

    OBJECTIVE: To assess interobserver agreement between pathologists in judging photographs of lymph node preparations of occult tumour cells of patients with colon cancer. DESIGN: Descriptive and comparative study of interobserver variability. METHODS: All lymph nodes of 82 pN0 patients with colon

  9. GPS radio occultation technique for measurement of the atmosphere above tropical cyclones

    DEFF Research Database (Denmark)

    Biondi, Riccardo; Neubert, Torsten; Syndergaard, Stig

    2009-01-01

    Water vapour transport to the upper troposphere (UT) and lower stratosphere (LS) by deep convective storms affects the radiation balance of the atmosphere and has been proposed as an important component of climate change. The aim of the work presented here is to understand if the GPS Radio Occult...... 2008 and reached a maximum intensity of Category 3....

  10. Occult hepatitis B virus infection is not associated with disease progression of chronic hepatitis C virus infection.

    Science.gov (United States)

    Cho, Junhyeon; Lee, Sang Soo; Choi, Yun Suk; Jeon, Yejoo; Chung, Jung Wha; Baeg, Joo Yeong; Si, Won Keun; Jang, Eun Sun; Kim, Jin-Wook; Jeong, Sook-Hyang

    2016-11-14

    To clarify the prevalence of occult hepatitis B virus (HBV) infection (OBI) and the association between OBI and liver disease progression, defined as development of liver cirrhosis or hepatocellular carcinoma (HCC), worsening of Child-Pugh class, or mortality in cases of chronic hepatitis C virus (HCV) infection. This prospective cohort study enrolled 174 patients with chronic HCV infection (chronic hepatitis, n = 83; cirrhosis, n = 47; HCC, n = 44), and evaluated disease progression during a mean follow-up of 38.7 mo. OBI was defined as HBV DNA positivity in 2 or more different viral genomic regions by nested polymerase chain reaction using 4 sets of primers in the S, C, P and X open reading frame of the HBV genome. The overall OBI prevalence in chronic HCV patients at enrollment was 18.4%, with 16.9%, 25.5% and 13.6% in the chronic hepatitis C, liver cirrhosis and HCC groups, respectively ( P = 0.845). During follow-up, 52 patients showed disease progression, which was independently associated with aspartate aminotransferase > 40 IU/L, Child-Pugh score and sustained virologic response (SVR), but not with OBI positivity. In 136 patients who were not in the SVR state during the study period, OBI positivity was associated with neither disease progression, nor HCC development. The prevalence of OBI in chronic HCV patients was 18.4%, and OBI was not associated with disease progression in South Koreans.

  11. Secretin-stimulating MRCP in patients with pancreatobiliary maljunction and occult pancreatobiliary reflux: direct demonstration of pancreatobiliary reflux

    Energy Technology Data Exchange (ETDEWEB)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Araki, Tsutomu [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan); Kitahara, Fumiaki; Sato, Tadashi [University of Yamanashi, First Department of Internal Medicine, Chuo-shi, Yamanashi (Japan); Itakura, Jun; Fujii, Hideki [University of Yamanashi, First Department of Surgery, Chuo-shi, Yamanashi (Japan)

    2007-09-15

    We propose the hypothesis that the enlargement of the common bile duct (CBD) or gallbladder (GB) that is occasionally demonstrated on magnetic resonance cholangiopancreatography (MRCP) after secretin stimulation is caused by pancreatobiliary reflux. Recently, occult pancreatobiliary reflux (OPR) has been demonstrated in patients without morphological pancreatobiliary maljunction (MPBM). The aim of this study was to evaluate the efficacy of secretin-stimulating MRCP (SMRCP) in the diagnosis of pancreatobiliary reflux. The study included 14 patients with MPBM and 32 patients with a normal pancreatobiliary junction. OPR was evaluated by bile collection and diagnosed in seven of the 32 patients. All the patients underwent SMRCP; the related findings were considered positive when enlargement of the CBD or GB was observed. Positive findings on SMRCP were observed in all MPBM patients. In the patients with normal pancreatobiliary junction, there was significant difference between the mean amylase levels in the patients with positive and negative SMRCP findings (mean, 4,755.7 and 29.7 IU/l). The sensitivity and specificity of SMRCP for diagnosing OPR was 85.7% and 68.0%, respectively. SMRCP provides a non invasive method for excluding PBR and can identify patients who could benefit from bile duct sampling to diagnose OPR. (orig.)

  12. Sizes of the Smallest Particles at Saturn Ring Edges from Diffraction in UVIS Stellar Occultations

    Science.gov (United States)

    Eckert, S.; Colwell, J. E.; Becker, T. M.; Esposito, L. W.

    2017-12-01

    Cassini's Ultraviolet Imaging Spectrograph (UVIS) has observed more than 150 ring stellar occultations since its arrival at Saturn in 2004. We use stellar occultation data from the UVIS High Speed Photometer (HSP) to identify diffraction signals at ring edges caused by small particles diffracting light into the detector and consequently increasing the signal above that of the unocculted star. The shape of a diffraction signal is indicative of the particle size distribution at the ring edge, which may be a dynamically perturbed region. Becker et al. (2015 Icarus doi:10.1016/j.icarus.2015.11.001) analyzed diffraction signals at the outer edge of the A Ring and the edges of the Encke Gap. We apply the Becker et al. (2015) model to the outer edge of the B Ring as well as the edges of ringlets within the C Ring and Cassini Division. In addition, we analyze diffraction signatures at the A Ring outer edge in 2 new occultations. The best-fit model signals to these occultations are consistent with the findings of Becker et al. (2015) who found an average minimum particle size amin =4.5 mm and average power law slope q=3.2. At the B Ring outer edge, we detect a diffraction signal in 10 of 28 occultations in which the diffraction signal would be observable according to our criteria for star brightness and observation geometry. We find a mean amin =11 mm and a mean q=3.0. At both edges of the so-called "Strange" ringlet (R6) we find a mean amin = 20 mm and mean q values of 3.0 and 2.8 at the inner and outer edges, respectively. In contrast, we do not observe any clear diffraction signals at either edge of the wider Huygens ringlet. This could imply an absence of cm-scale or smaller particles and indicates that collisions here may be less vigorous than at the other ring edges analyzed in this study. We detect diffraction in a small fraction ( 10%) of occultations at 3 ringlets within the Cassini Division: the Herschel ringlet, the Laplace ringlet, and the Barnard ringlet. We

  13. Occult pneumothorax in trauma patients: should this be sought in the focused assessment with sonography for trauma examination?

    Science.gov (United States)

    Tam, Michael M K

    2005-01-01

    At present, CT scan is the gold standard for detecting occult traumatic pneumothorax not apparent on supine chest X-ray radiograph. Recently there were suggestions to expand focused assessment with sonography for trauma (FAST) to include thoracic ultrasound for detecting pneumothorax. The aim of the present study is to determine the incidence of occult pneumothorax (as shown by CT) in the subgroup of trauma patients undergoing FAST. Review of all trauma patients with FAST done from 1 June 2001 to 31 October 2002. Incidence of occult pneumothorax as diagnosed by CT was determined. Patients were not counted as having true occult pneumothorax if they had chest drains inserted before arrival or imaging studies. Selected clinical findings were tested for association with occult pneumothorax. In total, 143 patients underwent FAST, of whom 137 (95.8%) had chest X-ray examination performed. Of the 137 patients 59 required CT abdomen and/or thorax. Occult pneumothorax was found in three patients (2.1%). A history of thorax and/or abdominal injury plus one or more of: (i) mechanisms potentially causing major trauma; (ii) abnormal chest examination; and (iii) chest X-ray radiograph abnormality in the absence of pneumothorax, was significantly associated with the presence of occult pneumothorax (P = 0.03, Fisher's exact test; sensitivity: 100%; specificity: 71%; likelihood ratio: 3.42). The incidence of occult pneumothorax in the subgroup of trauma patients undergoing FAST is low. It implies that routine screening for its presence by adding thoracic ultrasound to FAST is unnecessary. Identifying those at risk of occult pneumothorax for further investigation appeared feasible.

  14. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  15. Potentiometric determination of iodides in urine

    International Nuclear Information System (INIS)

    Gikolaev, B.A.; Primakova, L.N.; Rakhman'ko, E.M.

    1996-01-01

    Variants of potentiometric method: determination using a calibrations plot, the Gran method, and the double addition method are considered. The method of double additions of the test solution to the reference one is suggested as the most favorable method of determining iodides in urine under clinical laboratory conditions. Refs. 5, tabs. 2

  16. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... Answers (Q&A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / ... Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for educational purposes only. For ...

  17. CHROMagar Orientation Medium Reduces Urine Culture Workload

    Science.gov (United States)

    Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee

    2013-01-01

    Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839

  18. Urine ethanol concentration and alcohol hangover severity

    NARCIS (Netherlands)

    Brookhuis, Karel; Van De Loo, Aurora; Mackus, M.; Verster, Joris

    Background The aim of this study was to examine the relationship between urine ethanol concentration and alcohol hangover severity. Methods N = 36 healthy social drinkers participated in a naturalistic study, comprising a hangover day and a control day. N = 18 of them have regular hangovers (the

  19. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  20. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  1. Determination of natural thorium in urines

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Jammet, H.

    1959-01-01

    A procedure for the quantitative analysis of thorium in urine is described. After precipitation with ammonium hydroxide, dissolution of the precipitate, extraction at pH 4-4.2 with cupferron in chloroformic solution and mineralization, a colorimetric determination of thorium with thorin is performed. It is thus possible to detect about 2 γ of thorium in the sample. (author) [fr

  2. URINE CULTURE CONTAMINATION: A ONE-YEAR ...

    African Journals Online (AJOL)

    boaz

    Background: Urine culture contamination is a significant cause of delay in treatment of patients being investigated for urinary tract infection. ... Lowest contamination rates were in Emergency Paediatric Unit (EPU) and intensive ... The female gender was found to be the most significant predictor of higher contamination rate.

  3. Theoretical performance of serrated external occulters for solar coronagraphy. Application to ASPIICS

    Science.gov (United States)

    Rougeot, R.; Aime, C.

    2018-04-01

    Context. This study is made in the context of the future solar coronagraph ASPIICS of the ESA formation-flying mission Proba-3. Aims: In the context of solar coronagraphy, we provide a comparative study of the theoretical performance of serrated (or toothed) external occulters by varying the number and size of the teeth, which we compare to the sharp-edged and apodized disks. The tooth height is small (a few centimeters), to avoid hindering the observation of the solar corona near the limb. We first analyze the diffraction pattern produced by such occulters. In a second step, we compute the umbra profile by integration over the Sun. Methods: We explored a few methods to compute the diffraction pattern. Two of them were implemented. The first is based on 2D fast Fourier transformation (FFT) routines and a multiplication by the Fresnel filter of the form exp(-iπλzu2). Simple rules were derived and discussed to set the sampling conditions. The Maggi-Rubinowicz representation is then proposed as an alternative method, and is proven to be very efficient for this study. Results: Serrated occulters tend to create a two-level intensity pattern, the inner being the darker, which perfectly matches a previously reported geometrical prediction. The diffraction in this central region is lower by two to four orders of magnitude when compared to the sharp-edged disk. The achieved umbra level at the center ranges from 10-4 to below 10-7, depending on the geometry of the teeth. Conclusions: Our study shows that serrated occulters can achieve a high rejection and can almost reach the performance of the apodized disk when very many teeth are used. We prove that shaped occulters must be preferred to simple disks in solar and stellar coronagraphy.

  4. Predictive factors of occult neck metastasis in patients with oral squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Renato Fortes Bittar

    Full Text Available ABSTRACT INTRODUCTION: It is well established that cervical lymph node metastasis is the most important prognostic factor in patients with oral squamous cell carcinoma of the upper aerodigestive tract. The definition of parameters and classifications that could separate patients in groups of low, intermediate and high-risk is being attempted for several years. OBJECTIVE: The objective of this study was to determine possible predictive factors related to the occurrence of occult cervical lymph node metastasis through the analysis of histopathological reports of surgical specimens obtained after oral squamous cell carcinoma resection and selective neck dissections of patients initially classified as N0. METHODS: This was a primary, retrospective, observational, case-control study. Histopathological reports were reviewed to determine if some findings were related to the occurrence of occult lymph node metastasis. The events analyzed were oral cavity subsites, pT-stage, muscular infiltration, desmoplasia, vascular emboli, perineural infiltration, tumor thickness and compromised margins. RESULTS: Occult cervical metastasis accounted for 19.10 percent of the cases. Desmoplasia, perineural infiltration, tumor thickness and pT4a stage are predictive factors of occult neck metastasis (p-value = 0.0488, 0.0326, 0.0395, 0.0488, respectively. CONCLUSION: The accurate definition of predictive factors of occult cervical metastasis may guide the selection of patients that should be referred to radiotherapy, avoiding the unnecessary exposure of low-risk patients to radiation and allowing a better regional control of the disease in those of moderate or high risk.

  5. Stability of Synthetic Cathinones in Urine.

    Science.gov (United States)

    Glicksberg, Lindsay; Kerrigan, Sarah

    2018-03-01

    In this report, we evaluate the concentration, pH, temperature and analyte-dependent effects on cathinone stability in preserved human urine. A total of 22 synthetic cathinones were evaluated at 100 ng/mL and 1,000 ng/mL in pH 4 and pH 8 urine over 6 months. Specimens were stored at -20°C, 4°C, 20°C and 32°C. The stability of synthetic cathinones was highly dependent on urine pH and storage temperature. Cathinones were considerably more stable in acidic urine (pH 4) at low temperature. In alkaline urine (pH 8) at 32°C, significant losses (>20%) were observed within hours for the majority of drugs. In contrast, all drugs were stable in frozen and refrigerated urine at pH 4 for the duration of the study. These results highlight the importance of sample storage and the potential for pre-analytical changes in concentration during routine shipping and handling of specimens. Significant structural influence was also observed. Cathinones bearing a tertiary amine (pyrrolidine group) were significantly more stable than their secondary amine counterparts. The methylenedioxy group also exerted a significant stabilizing effect on both the tertiary and secondary amines. In the absence of the methylenedioxy group, no significant differences in stability were observed between the unsubstituted and ring substituted secondary amines. Half-lives at ambient temperature in pH 8 urine ranged from 9 h (3-fluoromethcathinone) to 4.3 months (methylenedioxypyrovalerone and 3,4-methylenedioxy-α-pyrrolidinobutiophenone), demonstrating the importance of analyte dependence, and the dual stabilizing effect of both the pyrollidine and methylenedioxy groups. Biological evidence may be subjected to a variety of environmental conditions prior to, and during transport to the forensic laboratory. These findings demonstrate the inherent instability of certain cathinone species in biological evidence under some conditions. Moreover, this study highlights the need for quantitative drug findings in

  6. Prothrombin fragment 1+2 in urine as a marker on coagulation activity in patients with suspected pulmonary embolism.

    Science.gov (United States)

    Wexels, Fredrik; Dahl, Ola E; Pripp, Are H; Seljeflot, Ingebjørg; Borris, Lars C; Haslund, Anniken; Gudmundsen, Tor E; Lauritzen, Trine; Lassen, Michael R

    2014-07-01

    We have recently reported that increased levels of urine prothrombin fragment 1+2 reflected radiologically verified deep vein thrombosis. In this study we evaluated whether urine prothrombin fragment 1+2 was associated with pulmonary embolism in non-selected patients. Patients with clinical suspected pulmonary embolism were interviewed on comorbidities and medications. Urine was collected from each patient before radiological examination and snap frozen until analysed on urine prothrombin fragment 1+2 with an ELISA kit. Imaging of the pulmonary arteries were conducted with contrast enhanced computer tomography. Pulmonary embolism was diagnosed in 44/197 patients. Non-significantly higher urine prothrombin fragment 1+2 levels were found in non-selected patients with pulmonary embolism vs. those without (p=0.324). Significantly higher urine prothrombin fragment 1+2 levels were found in the pulmonary embolism positive patients without comorbidities (n=13) compared to the control group (n=28) (p=0.009). The calculated sensitivity, specificity and negative predictive value using the lowest detectable urine prothrombin fragment 1+2 level was 82%, 34% and 87%, respectively. There was no significant urine prothrombin fragment 1+2 level difference in patients with and without pulmonary embolism. In non-comorbide pulmonary embolism positive patients the urine prothrombin fragment 1+2 levels were significantly higher compared to the control group. The negative predictive value found in this study indicates that uF1+2 has the potential to identify patients with a low risk of PE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Protein-Based Urine Test Predicts Kidney Transplant Outcomes

    Science.gov (United States)

    ... News Releases News Release Thursday, August 22, 2013 Protein-based urine test predicts kidney transplant outcomes NIH- ... supporting development of noninvasive tests. Levels of a protein in the urine of kidney transplant recipients can ...

  8. Epithelial Cells in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/epithelialcellsinurine.html Epithelial Cells in Urine To use the sharing features on ... page, please enable JavaScript. What is an Epithelial Cells in Urine Test? Epithelial cells are a type ...

  9. Molecular analysis of hepatitis B virus (HBV in an HIV co-infected patient with reactivation of occult HBV infection following discontinuation of lamivudine-including antiretroviral therapy

    Directory of Open Access Journals (Sweden)

    Costantini Andrea

    2011-11-01

    Full Text Available Abstract Background Occult hepatitis B virus (HBV infection (OBI is characterized by HBV DNA persistence even though the pattern of serological markers indicates an otherwise resolved HBV infection. Although OBI is usually clinically silent, immunocompromised patients may experience reactivation of the liver disease. Case presentation We report the case of an individual with human immunodeficiency virus (HIV infection and anti-HBV core antibody positivity, who experienced severe HBV reactivation after discontinuation of lamivudine-including antiretroviral therapy (ART. HBV sequencing analysis showed a hepatitis B surface antigen escape mutant whose presence in an earlier sample excluded reinfection. Molecular sequencing showed some differences between two isolates collected at a 9-year interval, indicating HBV evolution. Resumption of ART containing an emtricitabine/tenofovir combination allowed control of plasma HBV DNA, which fell to undetectable levels. Conclusion This case stresses the ability of HBV to evolve continuously, even during occult infection, and the effectiveness of ART in controlling OBI reactivation in HIV-infected individuals.

  10. Effect of Cow Urine on the Growth Characteristics of Fusarium lateritium, an Important Coffee Fungus in Zimbabwe

    Directory of Open Access Journals (Sweden)

    Timothy Gotora

    2014-01-01

    Full Text Available An in vitro assay was carried out to establish if cow urine at different concentrations (500 µL/mL, 300 µL/mL, 200 µL/mL, and 100 µL/mL can be used to control the growth of F. lateritium, the fungal agent causing Fusarium bark disease in coffee. The growth characteristics selected were conidial germination, germ tube length, mycelial growth rate, and sporulation. Copper oxychloride 50% W.P. was the standard, distilled water was the negative control, and undiluted cow urine was the positive control. The undiluted cow urine was most effective in inhibiting fungal growth with the rest of the cow urine concentrations showing dose dependent efficacy compared to the negative control (P < 0.01. Copper oxychloride had the highest efficacy of all treatments with the exception of the inhibition of mycelial growth where undiluted cow urine had higher efficacy and sporulation where efficacy was comparable to undiluted cow urine. There is potential for the use of cow urine as a means of controlling Fusarium bark disease with other advantages being availability, low cost, and limited environmental damage.

  11. Trends in the levels of urine and serum creatinine: data from NHANES 2001-2014.

    Science.gov (United States)

    Jain, Ram B

    2017-04-01

    Data from the National Health and Nutrition Examination Survey were used to study trends for urine and serum creatinine over 2001-2014 for those aged ≥20 years. In the absence of chronic kidney disease, levels of urine creatinine decreased for the total population, for those aged 20-29, 50-59, and ≥70 years, for males, and for Mexican Americans and other race/ethnicities. Levels of serum cotinine also exhibited a decreasing trend over 2001-2014 for the total population, for those aged 20-29 and 40-49 years, for females, and for non-Hispanic whites and Mexican Americans. In general, levels of serum creatinine and urine creatinine were positively correlated for chronic kidney disease stages 1-3 and negatively correlated for chronic kidney disease stages 4 and 5.

  12. High throughput-screening of animal urine samples: It is fast but is it also reliable?

    Science.gov (United States)

    Kaufmann, Anton

    2016-05-01

    Advanced analytical technologies like ultra-high-performance liquid chromatography coupled to high resolution mass spectrometry can be used for veterinary drug screening of animal urine. The technique is sufficiently robust and reliable to detect veterinary drugs in urine samples of animals where the maximum residue limit of these compounds in organs like muscle, kidney, or liver has been exceeded. The limitations and possibilities of the technique are discussed. The most critical point is the variability of the drug concentration ratio between the tissue and urine. Ways to manage the false positive and false negatives are discussed. The capability to confirm findings and the possibility of semi-targeted analysis are also addressed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Clinical accuracy of point-of-care urine culture in general practice

    DEFF Research Database (Denmark)

    Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller

    2017-01-01

    OBJECTIVE: To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. DESIGN: Prospective diagnostic...... uncomplicated, symptomatic UTI. MAIN OUTCOME MEASURES: (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply...... general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci...

  14. Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats.

    Science.gov (United States)

    Vientós-Plotts, Aida I; Behrend, Ellen N; Welles, Elizabeth G; Chew, Dennis J; Gaillard, Philippe R; Busler, Jessica N; Lee, Hollie P

    2018-05-01

    OBJECTIVE To evaluate effects of blood contamination on dipstick results, specific gravity (SG), and urine protein-to-urine creatinine ratio (UPCR) for urine samples from dogs and cats. SAMPLE Urine samples collected from 279 dogs and 120 cats. PROCEDURES Urine pools were made for each species (dogs [n = 60] and cats [30]). Blood was added to an aliquot of a pool, and serial dilutions were prepared with the remaining urine. Color and dipstick variables were recorded, and SG and UPCR were measured. For cats, 1 set of pools was used; for dogs, 2 sets were used. Comparisons were made between undiluted urine and spiked urine samples for individual colors. Repeated-measures ANOVA on ranks was used to compare dipstick scores and UPCR results; χ 2 tests were used to compare proteinuria categorizations (nonproteinuric, borderline, or proteinuric). RESULTS Any blood in the urine resulted in significantly increased dipstick scores for blood. In both species, scores for bilirubin and ketones, pH, and SG were affected by visible blood contamination. No significant difference for the dipstick protein reagent results was evident until a sample was visibly hematuric. The UPCR was significantly increased in dark yellow samples of both species. Proteinuria categorizations differed significantly between undiluted urine and urine of all colors, except light yellow. CONCLUSIONS AND CLINICAL RELEVANCE Any degree of blood contamination affected results of dipstick analysis. Effects depended on urine color and the variable measured. Microscopic blood contamination may affect the UPCR; thus, blood contamination may be a differential diagnosis for proteinuria in yellow urine samples.

  15. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    Science.gov (United States)

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  16. Male occult breast cancer with axillary lymph node metastasis as the first manifestation: A case report and literature review.

    Science.gov (United States)

    Xu, Ruixin; Li, Jianbin; Zhang, Yingjie; Jing, Hongbiao; Zhu, Youzhe

    2017-12-01

    Occult breast cancer (OBC) is extremely rare in males with neither symptoms in the breast nor abnormalities upon imaging examination. This current case report presents a young male patient who was diagnosed with male OBC first manifesting as axillary lymph node metastasis. The physical and imaging examination showed no primary lesions in either breasts or in other organs. The pathological results revealed infiltrating ductal carcinoma in the axillary lymph nodes. Immunohistochemical (IHC) staining was negative for estrogen receptor (ER), progesterone receptor (PR), cytokeratin (CK)20 and thyroid transcription factor-1 (TTF-1), positive for CK7, gross cystic disease fluid protein-15 (GCDFP-15), epithelial membrane antigen (EMA) and carcinoembryonic antigen (CEA), and suspicious positive for human epidermal receptor-2 (Her-2). On basis of IHC markers, particularly such as CK7, CK20 and GCDFP-15, and eliminating other malignancies, male OBC was identified in spite of negativity for hormone receptors. The patient underwent left axillary lymph node dissection (ALND) but not mastectomy. After the surgery, the patient subsequently underwent chemotherapy and radiotherapy. The patient is currently being followed up without any signs of recurrence. Carefully imaging examination and pathological analysis were particularly essential in the diagnosis of male OBC. The guidelines for managing male OBC default to those of female OBC and male breast cancer. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  17. Controls of nitrous oxide emission after simulated cattle urine deposition

    DEFF Research Database (Denmark)

    Baral, Khagendra Raj; Thomsen, Anton Gårde; Olesen, Jørgen E

    2014-01-01

    Urine deposited during grazing is a significant source of atmospheric nitrous oxide (N2O). The potential for N2O emissions from urine patches is high, and a better understanding of controls is needed. This study investigated soil nitrogen (N) dynamics and N2O emissions from cattle urine...

  18. Iodine and creatinine testing in urine dried on filter paper

    Energy Technology Data Exchange (ETDEWEB)

    Zava, Theodore T., E-mail: ttzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Kapur, Sonia, E-mail: soniak@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Zava, David T., E-mail: dzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States)

    2013-02-18

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R{sup 2} = 0.9483; creatinine: R{sup 2} = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs.

  19. Iodine and creatinine testing in urine dried on filter paper

    International Nuclear Information System (INIS)

    Zava, Theodore T.; Kapur, Sonia; Zava, David T.

    2013-01-01

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R 2 = 0.9483; creatinine: R 2 = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs

  20. Detection of Leptospiral DNA in the Urine of Donkeys on the Caribbean Island of Saint Kitts

    Directory of Open Access Journals (Sweden)

    Bernard Grevemeyer

    2017-01-01

    Full Text Available Leptospirosis is a global zoonosis caused by pathogenic spirochetes classified within the genus Leptospira. Leptospires live in the proximal renal tubules of reservoir or chronic carrier animals, and are shed in the urine. Naïve animals acquire infection either when they come in direct contact with a reservoir or infected animals or by exposure to environmental surface water or soil that is contaminated with their urine. In this study, urine samples from a herd of donkeys on the Caribbean island of St. Kitts were screened using a TaqMan-based real-time quantitative polymerase chain reaction (qPCR targeting a pathogen-specific leptospiral gene, lipl32. Out of 124 clinically normal donkeys, 22 (18% tested positive for leptospiral DNA in their urine. Water samples from two water troughs used by the donkeys were also tested, but were found to be free from leptospiral contamination. Detection of leptospiral DNA in the urine of clinically healthy donkeys may point to a role that these animals play in the maintenance of the bacteria on St. Kitts.

  1. Detection of Leptospiral DNA in the Urine of Donkeys on the Caribbean Island of Saint Kitts

    Science.gov (United States)

    Grevemeyer, Bernard; Vandenplas, Michel; Beigel, Brittney; Cho, Ellen; Willingham, Arve Lee; Verma, Ashutosh

    2017-01-01

    Leptospirosis is a global zoonosis caused by pathogenic spirochetes classified within the genus Leptospira. Leptospires live in the proximal renal tubules of reservoir or chronic carrier animals, and are shed in the urine. Naïve animals acquire infection either when they come in direct contact with a reservoir or infected animals or by exposure to environmental surface water or soil that is contaminated with their urine. In this study, urine samples from a herd of donkeys on the Caribbean island of St. Kitts were screened using a TaqMan-based real-time quantitative polymerase chain reaction (qPCR) targeting a pathogen-specific leptospiral gene, lipl32. Out of 124 clinically normal donkeys, 22 (18%) tested positive for leptospiral DNA in their urine. Water samples from two water troughs used by the donkeys were also tested, but were found to be free from leptospiral contamination. Detection of leptospiral DNA in the urine of clinically healthy donkeys may point to a role that these animals play in the maintenance of the bacteria on St. Kitts. PMID:29056661

  2. Determination of Deoxynivalenol in the Urine of Pregnant Women in the UK

    Directory of Open Access Journals (Sweden)

    Liz Wells

    2016-10-01

    Full Text Available Deoxynivalenol (DON is one of the most commonly occurring trichothecenes, produced mainly by Fusarium graminearum. Little is known about the effect of DON exposure or the levels of DON exposure that occur during pregnancy. The project aimed to provide data on levels of total DON and de-epoxi Deoxynivalenol (DOM-1 in pregnant human urine samples analysed by liquid chromatography-mass spectrometry (LC-MS. Morning urine samples were collected over two consecutive days from 42 volunteers and associated food consumption was recorded for the 24 h prior to the sample. Spearman’s rho non-parametric test for correlation was used to assess the data. Levels of DON did not differ significantly between day 1 (mean 29.7 ng/mL urine or 40.1 ng DON/mg creatinine and day 2 (mean 28.7 ng/mL urine or 38.8 ng DON/mg creatinine ng/mL/day urine samples. The only significant positive correlation was found between total ng DON/mg creatinine and parity (rho = 0.307, n = 42, p < 0.005 two-tailed and total ng DON/mg creatinine with baked goods on day 1 (rho = 0.532, n = 42, p < 0.0005 two-tailed. This study provides data on the DON levels in pregnancy in this suburban population and reassurance that those levels are within acceptable limits.

  3. Impact of pH on Urine Chemistry Assayed on Roche Analyzers.

    Science.gov (United States)

    Cohen, R; Alkouri, R; Tostivint, I; Djiavoudine, S; Mestari, F; Dever, S; Atlan, G; Devilliers, C; Imbert-Bismut, F; Bonnefont-Rousselot, D; Monneret, D

    2017-10-01

    The pH may impact the concentration of certain urinary parameters, making urine pre-treatment questionable. 1) Determining the impact of pH in vitro on the urinary concentration of chemistry parameters assayed on Roche Modular analyzers. 2) Evaluating whether concentrations depended on pH in non-pretreated urines from patients. 1) The optimal urinary pH values for each measurement were: 6.3 ± 0.8 (amylase), 6.5 (uric acid). Urinary creatinine, sodium and urea concentrations were not pH-dependent. 2) In urines from patients, the pH was negatively associated with the concentration of some urinary parameters. However, concentrations of all the parameters were strongly and positively correlated with urinary creatinine, and relationships with pH were no longer evidenced after creatinine-normalization. The need for urine pH adjustment does not seem necessary when considering renal function. However, from an analytical and accreditation standpoint, the relationship between urine pH and several parameters justifies its measurement.

  4. Novel Electron Spin Resonance-Enzyme Immunosorbent Assay for Detecting Occult Hepatitis B Infection in HCV Chronic Liver Disease

    Directory of Open Access Journals (Sweden)

    Hala Badawi

    2017-11-01

    Full Text Available Background: Hepatitis B virus infection in patients who lack detectable hepatitis B surface antigen (HBsAg is called occult hepatitis B infection (OHB. The very low level of HBV genome may hamper its detection by molecular techniques. Recently, a highly sensitive EIA utilizing a novel modified electron spin resonance (ESR technique (modified ESR-EIA was developed to detect HBsAg by measuring stabilized nitroxide radicals. Aim: to detect occult HBV infection, using ESR-EIA among HCV-related chronic liver disease (CLD Egyptian patients who were seronegative for HBsAg by standard EIA. Methods: The study was conducted on two periods of time; in 1st period, 72 inpatients in Tropical Medicine Department of TBRI, were enrolled in the study. They were divided into two groups; 44 seropositive anti-HCV patients (Group I, 28 seronegative anti-HCV patients (Group II. Sera were subjected to virological assays for HBsAg, HBeAg, anti-HBc IgM, anti-HBc IgG, anti-HBs, anti-HCV and HCV RNA. We also examined serum HBV DNA by polymerase chain reaction (PCR technique and real-time detection polymerase chain reaction (RTD-PCR. In the 2nd period; modified ESR-EIA was applied on 32 TBRI inpatients, 23 in Tropical Medicine Department (Group I and 9 from hemodialysis unit (Group II with HCV-related CLD. Results: OHB was detected in 18.1% and 86.9% of our patients in 2002 and 2006 respectively. In phase 1, there was a higher detection rate among HCV patients in Group I (25% than Group II (7%, with higher prevalence (52.4% in patients with positive HCV RNA in Group I versus those with negative HCV viremia (8% in Group II. HBV DNA by either PCR or RTD-PCR was negative in all patients of both groups as the HBV viral load of the samples were below detectable level of the methods used; less than 100 copies/ml. None of 9 hemodialysis patients were positive for OHB. Conclusion: The newly developed quantitative ESR-EIA technique represents a great evolution for screening and

  5. Biofilm antifungal susceptibility of Candida urine isolated from ambulatory patients

    Directory of Open Access Journals (Sweden)

    Débora da Luz Becker

    2016-07-01

    Full Text Available Background and Objectives: the association between the biofilm formations an antifungal resistance has been suggested to be an important factor in the pathogenesis of several Candida species. Besides, studies have included invasive candidiasis from hospitalized patients; however there are few studies that evaluated the species distribution, antifungal susceptibility and biofilm formation of Candida species isolated from ambulatory patients. Thus, the aim of this study was to evaluate whether biofilm producing contributes to antifungal resistance in Candida isolates from urine sample obtained from ambulatory patients. Methods: During one year, 25 urine samples positive for yeast were collected, stored and plated on agar supplemented with chloramphenicol and Sabouread left at room temperature for 5 days for subsequent: 52% (13/25 were C. albicans, 36% (9/25 C. tropicalis, 8% (2/25 C. krusei and 4% (1/25 C. parapsilosis. Results: The ability to form biofilm was detected in 23 (92% of the yeast studied and 15.4% (2/13 of C. albicans were fluconazole (FLU and ketoconazole (KET resistant, while 11.1% (1/9 of C. tropicalis were ketoconazole resistant and were anidulafungin (ANI non-susceptible. Conclusion: our results showed the high capacity for biofilm formation among Candida isolates from ambulatory patients.

  6. Lack of cross-reactivity of Ambien (zolpidem) with drugs in standard urine drug screens.

    Science.gov (United States)

    Piergies, A A; Sainati, S; Roth-Schechter, B

    1997-04-01

    To determine in healthy volunteers (men and women; 18 to 40 years old) the potential cross-reactivity of Ambien (zolpidem) and/or its metabolites with drugs that are screened by the Syva EMIT II and the Abbott ADx urine drug screens assays. Open-label, fixed-treatment sequence of 1 night each of treatment with zolpidem (10 mg) and temazepam (15 mg). Clinical Pharmacology Unit within a teaching hospital. Over a 24-hour period, presence or absence of positive results on the Syva EMIT II or the Abbott ADx urine drug assay system, each performed at two different laboratory assay sites. Following ingestion of zolpidem, no subject had any positive response in either laboratory to the Syva EMIT II or the Abbott ADx urine drug screen assays at 0, 4, 8, 12, and 24 hours postdose. During the same time period, all subjects had measurable zolpidem plasma concentrations at 1.5 and 8 hours postdose, with mean concentrations of 115.2 ng/mL and 30.1 ng/mL, respectively (in agreement with its half-life of 2.5 hours). The positive response rate at 10 hours after ingestion of Restoril (temazepam) among the four laboratory/assay combinations ranged from 36.8% to 73.7%, a range that is within the reported response rates for these tests. These data indicate that zolpidem will not cross-react in standard urine drug screens with benzodiazepines, opiates, barbiturates, cocaine, cannabinoids, or amphetamines.

  7. Screening for urine abnormalities among preschool children in western Saudi Arabia

    Science.gov (United States)

    Alharthi, Abdulla A.; Taha, Azza A.; Edrees, Awatif E.; Elnawawy, Ali N.; Abdelrahman, Azza H.

    2014-01-01

    Objectives: To estimate the frequency of urinary problems among preschool children. Methods: In this cross-sectional study, 1000 preschool asymptomatic children attending the outpatient clinics of the Children’s Hospital, Taif, Kingdom of Saudi Arabia between August 2013 and December 2013 were subjected to dipstick urine analysis. Microscopic examination was performed for the abnormal dipstick samples, and children with hematuria were investigated for kidney function. Results: Dipstick urine analysis revealed abnormal findings in 25.1% of the screened children. The most common dipstick abnormalities were positive nitrite test in 18.1%, hematuria in 16.9%, and positive leukocyte esterase test in 14.3% of the cases. The most common abnormality in microscopic urine examination was crystals in 13% of the cases. Pyuria were evident in 5% of cases and hematuria in 2.5%. The most common bacteria in positive urine culture samples was Escherichia coli in 62.6%. Conclusion: In view of these important findings, dipstick screening should be implemented in preschool children. PMID:25491212

  8. Voided urine versus bladder washing cytology for detection of urothelial carcinoma: which is better?

    Science.gov (United States)

    Keller, Anna Krarup; Jensen, Jørgen Bjerggaard

    2017-08-01

    Cytology is recommended as part of the follow-up of high-grade non-muscle-invasive bladder cancer (NMIBC). However, currently there are no solid guideline recommendations regarding the use of voided urine versus bladder washing for cytology as part of the diagnosis or follow-up of NMIBC. The aim of this study was to investigate whether the cytological outcome was equal regarding the two techniques. The authors reviewed all outpatient flexible cystoscopies carried out in their department in 2013. Patient records in the registry of pathology were examined and those with simultaneous urine and bladder washing cytology were included. Previous urothelial disease and positive histology within 3 months after the cystoscopy were registered. A total of 1458 patients had both voided urine and bladder washing cytology and were included in the study, of whom 643 (44%) had a history of urothelial disease. An equal outcome of urine and bladder washing cytology was found in 1447 patients (99.2%). For the remaining 11 patients, only four patients underwent further examinations based on cytology findings in addition to what had already been planned after cystoscopy. Of the included patients, 100 (6.9%) had a positive histological outcome within 3 months. In most patients, no relevant difference between voided urine and bladder washing cytology was observed. Therefore, if cytology is indicated, it is recommended to use the test that is most readily available locally. The additional gain in using both urine and bladder wash is minimal, and can therefore be discarded.

  9. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    Science.gov (United States)

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Life cycle comparison of centralized wastewater treatment and urine source separation with struvite precipitation: Focus on urine nutrient management.

    Science.gov (United States)

    Ishii, Stephanie K L; Boyer, Treavor H

    2015-08-01

    Alternative approaches to wastewater management including urine source separation have the potential to simultaneously improve multiple aspects of wastewater treatment, including reduced use of potable water for waste conveyance and improved contaminant removal, especially nutrients. In order to pursue such radical changes, system-level evaluations of urine source separation in community contexts are required. The focus of this life cycle assessment (LCA) is managing nutrients from urine produced in a residential setting with urine source separation and struvite precipitation, as compared with a centralized wastewater treatment approach. The life cycle impacts evaluated in this study pertain to construction of the urine source separation system and operation of drinking water treatment, decentralized urine treatment, and centralized wastewater treatment. System boundaries include fertilizer offsets resulting from the production of urine based struvite fertilizer. As calculated by the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI), urine source separation with MgO addition for subsequent struvite precipitation with high P recovery (Scenario B) has the smallest environmental cost relative to existing centralized wastewater treatment (Scenario A) and urine source separation with MgO and Na3PO4 addition for subsequent struvite precipitation with concurrent high P and N recovery (Scenario C). Preliminary economic evaluations show that the three urine management scenarios are relatively equal on a monetary basis (<13% difference). The impacts of each urine management scenario are most sensitive to the assumed urine composition, the selected urine storage time, and the assumed electricity required to treat influent urine and toilet water used to convey urine at the centralized wastewater treatment plant. The importance of full nutrient recovery from urine in combination with the substantial chemical inputs required for N recovery

  11. An innovative HIV testing service using the internet: Anonymous urine delivery testing service at drugstores in Beijing, China.

    Directory of Open Access Journals (Sweden)

    Xiaoxia He

    Full Text Available Innovative human immunodeficiency virus (HIV testing services will be needed to achieve the first 90 (90% of HIV-positive persons aware of their infection status of the 90-90-90 target in China. Here, we describe an internet-based urine delivery testing service delivered through three pilot drugstores in Beijing that send specimens to a designated laboratory for HIV. From May 2016 to January 2017, we provided 500 HIV urine-testing service packs for display at the drugstores, and a total of 430 (86.0% urine specimens were mailed back. All of the 430 urine specimens were of good quality and were tested. 70 urine specimens were HIV positive, showing a 16.3% (70/430 positivity rate. A total of 94.3% (66/70 of the HIV-positive participants obtained their test results through the internet, and 69.7% (46/66 of these participants received follow-up care. A total of 40 out of 46 (87.0% participants agreed to have their results confirmed by a blood test, and 39 out of 40 (97.5% participants were confirmed as HIV-1 positive, including two individuals that were previously diagnosed. Lastly, 28 out of 37 (75.7% of the study participants were referred to the hospital and provided free antiviral treatment. Our data indicate that this innovative HIV testing service is effective and play an important role in HIV testing and surveillance.

  12. An innovative HIV testing service using the internet: Anonymous urine delivery testing service at drugstores in Beijing, China.

    Science.gov (United States)

    He, Xiaoxia; Liu, Guowu; Xia, Dongyan; Feng, Xia; Lv, Yi; Cheng, Huanyi; Wang, Yuehua; Lu, Hongyan; Jiang, Yan

    2018-01-01

    Innovative human immunodeficiency virus (HIV) testing services will be needed to achieve the first 90 (90% of HIV-positive persons aware of their infection status) of the 90-90-90 target in China. Here, we describe an internet-based urine delivery testing service delivered through three pilot drugstores in Beijing that send specimens to a designated laboratory for HIV. From May 2016 to January 2017, we provided 500 HIV urine-testing service packs for display at the drugstores, and a total of 430 (86.0%) urine specimens were mailed back. All of the 430 urine specimens were of good quality and were tested. 70 urine specimens were HIV positive, showing a 16.3% (70/430) positivity rate. A total of 94.3% (66/70) of the HIV-positive participants obtained their test results through the internet, and 69.7% (46/66) of these participants received follow-up care. A total of 40 out of 46 (87.0%) participants agreed to have their results confirmed by a blood test, and 39 out of 40 (97.5%) participants were confirmed as HIV-1 positive, including two individuals that were previously diagnosed. Lastly, 28 out of 37 (75.7%) of the study participants were referred to the hospital and provided free antiviral treatment. Our data indicate that this innovative HIV testing service is effective and play an important role in HIV testing and surveillance.

  13. Occult HBV infection status among chronic hepatitis C and hemodialysis patients in Northeastern Egypt: regional and national overview.

    Science.gov (United States)

    Mandour, Mohamed; Nemr, Nader; Shehata, Atef; Kishk, Rania; Badran, Dahlia; Hawass, Nashaat

    2015-01-01

    Occult hepatitis B infection (OBI) is considered to be one of the major risks for patients suffering from end-stage renal disease (ESRD) on regular hemodialysis (HD) and patients with chronic hepatitis C virus (HCV) infection. This study compared the prevalence of OBI among these two high-risk groups in the Suez Canal region, Northeastern Egypt, to obtain a better national overview of the magnitude of OBI in this region. Serum samples were collected from 165 HD patients and 210 chronic HCV-infected patients. Anti-HCV antibody, hepatitis B surface antigen (HBsAg), total hepatitis B core (anti-HBc) antibody, and hepatitis B surface antibody (anti-HBs) were detected by enzyme-linked immunosorbent assay (ELISA). HCV RNA was detected using a quantitative real-time RT-PCR assay, and HBV was detected using a nested PCR. All patients were negative for HBsAg. A total of 49.1% and 25.2% of the patients in the HD and HCV groups, respectively, were anti-HBc-positive. In addition, more anti-HBs-positive patients were detected in the HD group compared to the HCV group (52.1% and 11.4%, respectively). Three cases were positive for HBV DNA in the HD group, while eighteen positive cases were detected in the HCV group. Both study groups showed significant differences in serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) level as well as anti-HBc, anti-HBs and HBV-DNA positivity. OBI was more prevalent among chronic HCV patients than HD patients in the Suez Canal region, Egypt, with rates of 8.5% and 1.8%, respectively. However, more precise assessment of this infection requires regular patient follow-up using HBV DNA detection methods.

  14. Mechanisms of urine concentration and dilution (1961)

    International Nuclear Information System (INIS)

    Morel, F.; Guinnebault, M.

    1961-01-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [fr

  15. Radioimmunoassay of urine oxytocin in man

    International Nuclear Information System (INIS)

    Zebidi, A.; Geelen, G.; Allevard, A.M.; Sempore, B.; Jarsaillon, E.; Meunier, C.; Gharib, C.

    1978-01-01

    A radioimmunoassay (RIA) for oxytocin (OT) in urine is described. 125 I-OT was prepared, and antibodies were raised in rabbits against OT coupled to bovine serumalbumine. This allowed us to set up a RIA for OT which limit of detection is 1.25 pg/tube (0.6 μU). The use of an extraction procedure using CG 50 Amberlite is essential. The recovery after extraction reaches 70.5 %. pH 5 is the optimum pH were urine samples must be stored. The superposition of the elution peak of endogenous OT on that of exogenous hormone is an argument in favour of the validity of such an extraction procedure. Daily urinary excretion of OT reaches 9.58 mU +- 3.48 in 18 healthy young men [fr

  16. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    Science.gov (United States)

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  17. Phenylbutyrate therapy for maple syrup urine disease

    OpenAIRE

    Brunetti-Pierri, Nicola; Lanpher, Brendan; Erez, Ayelet; Ananieva, Elitsa A.; Islam, Mohammad; Marini, Juan C.; Sun, Qin; Yu, Chunli; Hegde, Madhuri; Li, Jun; Wynn, R. Max; Chuang, David T.; Hutson, Susan; Lee, Brendan

    2010-01-01

    Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate in urea cycle disorder patients has been associated with a selective reduction in branched-chain amino acids (BCAA) in spite of adequate dietary protein intake. Based on this clinical observation, we investigated the potential of phenylbutyrate treatment to lower BCAA and their corresponding α-keto acids (BCKA) in patients with classic and variant late-onset forms of maple syrup urine disease (MSUD). We also performed in vitr...

  18. Environmental heat stress enhances crystallization in urine

    Science.gov (United States)

    Setyawan, H.; Pratiwi, Q. C.; Sjarifah, I.; Atmojo, T. B.; Khotijah

    2018-03-01

    Over the past several decades, agriculture and plantations have been used as the main livelihood of most of the Karanganyar residents. However, these two sources of living are now replaced by industrial areas that employ thousands of people in that district. The development of this industry triggers multiple environmental impacts, including ecosystem and temperature changes. In consequence, there is an increase in air temperature that can cause a variety of diseases, especially in the workplace. According to the International Labour Organization (ILO) data in 2013, one worker dies every 15 second due to a work accident and 160 workers are suffering from the occupational disease. In Indonesia, the incidence of crystallization in urine is actually still unknown, but it is estimated that there are 170,000 cases annually. A high temperature or called heat stress is one among many factors causing this disease to appear. The workers in the textile industry, especially in the Finishing Department Kusumahadi Co. Ltd that exposed heat stress from the finishing machines and inadequate ventilation. This hot working climate causes the human body to adapt in the form of body cooling mechanism or called sweating This adaptation can cause an increase in sweat production and decrease the production of urine. If it is not followed by consuming the recommended amount of water intake, it can result in the precipitation of body salts that, in a long time, will cause crystallization in urine. The research used the analytic observational designs for a cross-sectional study. There were 34 samples collected from 57 finishing workers. The data were analyzed using Spearman correlation test. The results showed that heat stress (p=0,015) and water intake (p=0,034) has a significant correlation with crystallization in urine.

  19. Determination of uranium in urine by fluorometry

    International Nuclear Information System (INIS)

    Afsar, M.; Aziz, A.; Mubarak, M.A.

    1978-01-01

    The report describes fluorometric determination of traces of uranium in the urine of mine workers and persons handling uranium. After preliminary treatment uranium is extracted by solvent extraction with TBP:MIBK mixtures. An aliquot of the extracted solution is fused with high carbonate flux at 650 0 C in platinum dishes. The fluorescence of fused sample is measured using a fluorometer. Various fusion parameters are discussed. The procedure for the operation and calibration of fluorometer is also described

  20. Comparison of two preparatory techniques for urine cytology.

    Science.gov (United States)

    Dhundee, J; Rigby, H S

    1990-01-01

    Two methods of preparation of urine for cytology were compared retrospectively. In method 1 cells in the urine were fixed after the preparation of the smear; in method 2 the cells were fixed before smear preparation. Urine cytology reports were correlated with subsequent histological analysis. The specificities of urine cytology using both methods were high (99%). The sensitivity using method 1 was 87%; using method 2 it was 65%. This difference was significant. The cell preparation technique therefore significantly changes the sensitivity of urine cytology. Cellular fixation after smear preparation is preferable to smear preparation after fixation. PMID:2266176