WorldWideScience

Sample records for positive semi-definite 3-d

  1. CT-image based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning

    International Nuclear Information System (INIS)

    Polgar, C.; Major, T.; Somogyi, A.; Takacsi-Nagy, Z.; Mangel, L.C.; Fodor, J.; Nemeth, G.; Forrai, G.; Sulyok, Z.

    2000-01-01

    In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single double and triple plane implant was used in 6,89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. Results: With the help of conformal semi-3D and 3D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25.1% with semi-3-D planning, however, its was increased by 16.2% with 3-D planning, compared to the 2-D planning. (orig.) [de

  2. CT-image-based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning.

    Science.gov (United States)

    Polgár, C; Major, T; Somogyi, A; Takácsi-Nagy, Z; Mangel, L C; Forrai, G; Sulyok, Z; Fodor, J; Németh, G

    2000-03-01

    To compare the conventional 2-D, the simulator-guided semi-3-D and the recently developed CT-guided 3-D brachytherapy treatment planning in the interstitial radiotherapy of breast cancer. In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single, double and triple plane implant was used in 6, 89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3-D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. With the help of conformal semi-3-D and 3-D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25

  3. CT-image based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Polgar, C.; Major, T.; Somogyi, A.; Takacsi-Nagy, Z.; Mangel, L.C.; Fodor, J.; Nemeth, G. [Orszagos Onkologiai Intezet, Budapest (Hungary). Dept. of Radiotherapy; Forrai, G. [Haynal Imre Univ. of Health Sciences, Budapest (Hungary). Dept. of Radiology; Sulyok, Z. [Orszagos Onkologiai Intezet, Budapest (Hungary). Dept. of Surgery

    2000-03-01

    In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single double and triple plane implant was used in 6,89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. Results: With the help of conformal semi-3D and 3D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25.1% with semi-3-D planning, however, its was increased by 16.2% with 3-D planning, compared to the 2-D planning. (orig.) [German] Bei 103 Patientinnen mit Mammakarzinom der Stadien T1

  4. Semi- and virtual 3D dosimetry in clinical practice

    DEFF Research Database (Denmark)

    Korreman, S. S.

    2013-01-01

    In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D...... involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification...... measurements with various aims....

  5. A semi-automatic method for positioning a femoral bone reconstruction for strict view generation.

    Science.gov (United States)

    Milano, Federico; Ritacco, Lucas; Gomez, Adrian; Gonzalez Bernaldo de Quiros, Fernan; Risk, Marcelo

    2010-01-01

    In this paper we present a semi-automatic method for femoral bone positioning after 3D image reconstruction from Computed Tomography images. This serves as grounding for the definition of strict axial, longitudinal and anterior-posterior views, overcoming the problem of patient positioning biases in 2D femoral bone measuring methods. After the bone reconstruction is aligned to a standard reference frame, new tomographic slices can be generated, on which unbiased measures may be taken. This could allow not only accurate inter-patient comparisons but also intra-patient comparisons, i.e., comparisons of images of the same patient taken at different times. This method could enable medical doctors to diagnose and follow up several bone deformities more easily.

  6. Positivity for Convective Semi-discretizations

    KAUST Repository

    Fekete, Imre

    2017-04-19

    We propose a technique for investigating stability properties like positivity and forward invariance of an interval for method-of-lines discretizations, and apply the technique to study positivity preservation for a class of TVD semi-discretizations of 1D scalar hyperbolic conservation laws. This technique is a generalization of the approach suggested in Khalsaraei (J Comput Appl Math 235(1): 137–143, 2010). We give more relaxed conditions on the time-step for positivity preservation for slope-limited semi-discretizations integrated in time with explicit Runge–Kutta methods. We show that the step-size restrictions derived are sharp in a certain sense, and that many higher-order explicit Runge–Kutta methods, including the classical 4th-order method and all non-confluent methods with a negative Butcher coefficient, cannot generally maintain positivity for these semi-discretizations under any positive step size. We also apply the proposed technique to centered finite difference discretizations of scalar hyperbolic and parabolic problems.

  7. 3D primary grain shapes resulting from semi-solid metal processing

    CSIR Research Space (South Africa)

    Curle, Ulyate A

    2017-07-01

    Full Text Available ) size. Are these 2D globules also spherical in shape in 3D or are these 2D shapes remnants of the 3D shapes after sectioning along planes? An Al-Si-Mg alloy is semi-solid processed using a patented processing coil that induces contactless stirring while...

  8. Performance evaluation of 3D vision-based semi-autonomous control method for assistive robotic manipulator.

    Science.gov (United States)

    Ka, Hyun W; Chung, Cheng-Shiu; Ding, Dan; James, Khara; Cooper, Rory

    2018-02-01

    We developed a 3D vision-based semi-autonomous control interface for assistive robotic manipulators. It was implemented based on one of the most popular commercially available assistive robotic manipulator combined with a low-cost depth-sensing camera mounted on the robot base. To perform a manipulation task with the 3D vision-based semi-autonomous control interface, a user starts operating with a manual control method available to him/her. When detecting objects within a set range, the control interface automatically stops the robot, and provides the user with possible manipulation options through audible text output, based on the detected object characteristics. Then, the system waits until the user states a voice command. Once the user command is given, the control interface drives the robot autonomously until the given command is completed. In the empirical evaluations conducted with human subjects from two different groups, it was shown that the semi-autonomous control can be used as an alternative control method to enable individuals with impaired motor control to more efficiently operate the robot arms by facilitating their fine motion control. The advantage of semi-autonomous control was not so obvious for the simple tasks. But, for the relatively complex real-life tasks, the 3D vision-based semi-autonomous control showed significantly faster performance. Implications for Rehabilitation A 3D vision-based semi-autonomous control interface will improve clinical practice by providing an alternative control method that is less demanding physically as well cognitively. A 3D vision-based semi-autonomous control provides the user with task specific intelligent semiautonomous manipulation assistances. A 3D vision-based semi-autonomous control gives the user the feeling that he or she is still in control at any moment. A 3D vision-based semi-autonomous control is compatible with different types of new and existing manual control methods for ARMs.

  9. A semi-automatic 2D-to-3D video conversion with adaptive key-frame selection

    Science.gov (United States)

    Ju, Kuanyu; Xiong, Hongkai

    2014-11-01

    To compensate the deficit of 3D content, 2D to 3D video conversion (2D-to-3D) has recently attracted more attention from both industrial and academic communities. The semi-automatic 2D-to-3D conversion which estimates corresponding depth of non-key-frames through key-frames is more desirable owing to its advantage of balancing labor cost and 3D effects. The location of key-frames plays a role on quality of depth propagation. This paper proposes a semi-automatic 2D-to-3D scheme with adaptive key-frame selection to keep temporal continuity more reliable and reduce the depth propagation errors caused by occlusion. The potential key-frames would be localized in terms of clustered color variation and motion intensity. The distance of key-frame interval is also taken into account to keep the accumulated propagation errors under control and guarantee minimal user interaction. Once their depth maps are aligned with user interaction, the non-key-frames depth maps would be automatically propagated by shifted bilateral filtering. Considering that depth of objects may change due to the objects motion or camera zoom in/out effect, a bi-directional depth propagation scheme is adopted where a non-key frame is interpolated from two adjacent key frames. The experimental results show that the proposed scheme has better performance than existing 2D-to-3D scheme with fixed key-frame interval.

  10. A conservative scheme for 2D and 3D adaptive semi-Lagrangian advection

    OpenAIRE

    Behrens, Jörn; Mentrup, Lars

    2005-01-01

    This article describes a 2D and 3D adaptive and mass conservingsemi-Lagrangian advection scheme for atmospheric transport problems. Fromthe integral form of the conservation law we derive a semi-Lagrangian schemebased on conservation of mass along trajectories. The mapping of mass fromthe old (adaptively refined and possibly different) grid to the upstream controlvolume is performed by a mass packet based scheme, essentially consistingof a sub-grid discretization. We validate the new adaptive...

  11. A positive semi-definite action in a Kaluza-Klein theory with compactification onto time-like extra dimensions

    International Nuclear Information System (INIS)

    Pollock, M.D.

    1986-01-01

    We consider the (4+N)-dimensional theory whose Lagrangian function is Lsub(4+N)=√-g-circumflex α R-circumflex 2 , where R-circumflex is the Ricci scalar and α is a positive constant. The metric is g-circumflexsub(AB)= diag(gsub(ab), phi -1 g-barsub(mn)). Dimensional reduction leads to an effective four-dimensional Lagrangian of induced-gravity type. The positive semi-definiteness of L avoids the difficulties, pointed out recently by Horowitz and by Rubakov, which can arise in quantum cosmology when the (Euclidean) action becomes negative. The compactification is onto a time-like internal space g-barsub(mn), as suggested by Aref'eva and Volovich, giving a four-dimensional de Sitter space-time with phi=constant, which however is classically unstable on a time scale approx. H -1 . Decrease of the radius phisup(-1/2) of the internal space is ultimately halted by quantum effects, via some V(phi), and L 4 then includes the usual Hilbert term and a cosmological constant. (author)

  12. A generic semi-implicit coupling methodology for use in RELAP5-3D(c)

    International Nuclear Information System (INIS)

    Weaver, W.L.; Tomlinson, E.T.; Aumiller, D.L.

    2002-01-01

    A generic semi-implicit coupling methodology has been developed and implemented in the RELAP5-3D (c) computer program. This methodology allows RELAP5-3D (c) to be used with other computer programs to perform integrated analyses of nuclear power reactor systems and related experimental facilities. The coupling methodology potentially allows different programs to be used to model different portions of the system. The programs are chosen based on their capability to model the phenomena that are important in the simulation in the various portions of the system being considered and may use different numbers of conservation equations to model fluid flow in their respective solution domains. The methodology was demonstrated using a test case in which the test geometry was divided into two parts, each of which was solved as a RELAP5-3D (c) simulation. This test problem exercised all of the semi-implicit coupling features that were implemented in RELAP5-3D (c) The results of this verification test case show that the semi-implicit coupling methodology produces the same answer as the simulation of the test system as a single process

  13. Old and New about Positive Definite Matrices

    Czech Academy of Sciences Publication Activity Database

    Fiedler, Miroslav

    2015-01-01

    Roč. 484, 1 November (2015), s. 496-503 ISSN 0024-3795 R&D Projects: GA ČR(CZ) GAP108/11/0853 Institutional support: RVO:67985807 Keywords : positive definite matrix * normalized positive definite matrix * sign pattern Subject RIV: BA - General Mathematics Impact factor: 0.965, year: 2015

  14. Expedient Gap Definition Using 3D LADAR

    Science.gov (United States)

    2006-09-01

    Research and Development Center (ERDC), ASI has developed an algorithm to reduce the 3D point cloud acquired with the LADAR system into sets of 2D...ATO IV.GC.2004.02. The GAP Program is conducted by the U.S. Army Engineer Research and Development Center (ERDC) in conjunction with the U.S. Army...Introduction 1 1 Introduction Background The Battlespace Gap Definition and Defeat ( GAP ) Program is conducted by the U.S. Army Engineer Research and

  15. Effect of Ultrasonic Vibration on Mechanical Properties of 3D Printing Non-Crystalline and Semi-Crystalline Polymers.

    Science.gov (United States)

    Li, Guiwei; Zhao, Ji; Wu, Wenzheng; Jiang, Jili; Wang, Bofan; Jiang, Hao; Fuh, Jerry Ying Hsi

    2018-05-17

    Fused deposition modeling 3D printing has become the most widely used additive manufacturing technology because of its low manufacturing cost and simple manufacturing process. However, the mechanical properties of the 3D printing parts are not satisfactory. Certain pressure and ultrasonic vibration were applied to 3D printed samples to study the effect on the mechanical properties of 3D printed non-crystalline and semi-crystalline polymers. The tensile strength of the semi-crystalline polymer polylactic acid was increased by 22.83% and the bending strength was increased by 49.05%, which were almost twice the percentage increase in the tensile strength and five times the percentage increase in the bending strength of the non-crystalline polymer acrylonitrile butadiene styrene with ultrasonic strengthening. The dynamic mechanical properties of the non-crystalline and semi-crystalline polymers were both improved after ultrasonic enhancement. Employing ultrasonic energy can significantly improve the mechanical properties of samples without modifying the 3D printed material or adjusting the forming process parameters.

  16. New 3-D coordination polymers based on semi-rigid V-shape tetracarboxylates

    International Nuclear Information System (INIS)

    Huang, Jing-Jing; Xu, Wei; Wang, Yan-Ning; Yu, Jie-Hui; Zhang, Ping; Xu, Ji-Qing

    2015-01-01

    Under the hydrothermal conditions, the reactions of transition-metal salts, tetracarboxylic acids and N,N′-donor ligands yielded three new coordination polymers as [Cu 4 (fph) 2 (bpe) 3 (H 2 O) 2 ]·2H 2 O (fph=4,4′-(hexafluoroisopropylidene)diphthalate, bpe=1,2-bis(pyridyl)ethylene) 1, [Co 2 (fph)(bpa) 2 (H 2 O) 2 ]·3H 2 O (bpa=1,2-bis(pyridyl)ethylane) 2, and [Ni(H 2 O)(H 2 oph)(bpa)] (oph=4,4′-oxydiphthalate) 3. X-ray single-crystal diffraction analysis revealed that the title three compounds all possess the three-dimensional (3-D) network structures. For compound 1, the fph molecules first link the Cu 2+ ions into a two-dimensional (2-D) wave-like layer with a (4,4) topology. The bpe molecules act as the second linkers, extending the 2-D layers into a 3-D network. For compound 2, the fph molecules still serve as the first connectors, linking the Co 2+ ions into a one-dimensional (1-D) tube-like chain. Then the bpa molecules propagate the chains into a 3-D (4,4,4)-connected network. In the formation of the 3-D network of compound 3, the oph molecule does not play a role. The bpa molecules as well as the water molecules act as a mixed bridge. Only a kind of 4-connected metal node is observed in compound 3. The magnetic properties of compounds 1–3 were investigated and all exhibit the predominant antiferromegnetic magnetic behaviors. - Graphical abstract: Structures of three semi-rigid V-shape tetracarboxylate-based coordination polymers were reported, and their magnetic properties were investigated. - Highlights: • Structures of three tetracarboxylate-based coordination polymers were reported. • Role of organic bases in metal–tetracarboxylate compounds was discussed. • Characters of V-shape and semi-rigidity for tetracarboxylate play a key role in crystal growth. • Their magnetic properties were investigated

  17. New 3-D coordination polymers based on semi-rigid V-shape tetracarboxylates

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jing-Jing; Xu, Wei; Wang, Yan-Ning [College of Chemistry, Jilin University, Jiefang Road 2519, Changchun 130023, Jilin (China); State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, Jilin University, Qianjin Road 2699, Changchun 130012, Jilin (China); Yu, Jie-Hui, E-mail: jhyu@jlu.edu.cn [College of Chemistry, Jilin University, Jiefang Road 2519, Changchun 130023, Jilin (China); State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, Jilin University, Qianjin Road 2699, Changchun 130012, Jilin (China); Zhang, Ping, E-mail: zhangping@jlu.edu.cn [College of Chemistry, Jilin University, Jiefang Road 2519, Changchun 130023, Jilin (China); Xu, Ji-Qing [College of Chemistry, Jilin University, Jiefang Road 2519, Changchun 130023, Jilin (China); State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, Jilin University, Qianjin Road 2699, Changchun 130012, Jilin (China)

    2015-03-15

    Under the hydrothermal conditions, the reactions of transition-metal salts, tetracarboxylic acids and N,N′-donor ligands yielded three new coordination polymers as [Cu{sub 4}(fph){sub 2}(bpe){sub 3}(H{sub 2}O){sub 2}]·2H{sub 2}O (fph=4,4′-(hexafluoroisopropylidene)diphthalate, bpe=1,2-bis(pyridyl)ethylene) 1, [Co{sub 2}(fph)(bpa){sub 2}(H{sub 2}O){sub 2}]·3H{sub 2}O (bpa=1,2-bis(pyridyl)ethylane) 2, and [Ni(H{sub 2}O)(H{sub 2}oph)(bpa)] (oph=4,4′-oxydiphthalate) 3. X-ray single-crystal diffraction analysis revealed that the title three compounds all possess the three-dimensional (3-D) network structures. For compound 1, the fph molecules first link the Cu{sup 2+} ions into a two-dimensional (2-D) wave-like layer with a (4,4) topology. The bpe molecules act as the second linkers, extending the 2-D layers into a 3-D network. For compound 2, the fph molecules still serve as the first connectors, linking the Co{sup 2+} ions into a one-dimensional (1-D) tube-like chain. Then the bpa molecules propagate the chains into a 3-D (4,4,4)-connected network. In the formation of the 3-D network of compound 3, the oph molecule does not play a role. The bpa molecules as well as the water molecules act as a mixed bridge. Only a kind of 4-connected metal node is observed in compound 3. The magnetic properties of compounds 1–3 were investigated and all exhibit the predominant antiferromegnetic magnetic behaviors. - Graphical abstract: Structures of three semi-rigid V-shape tetracarboxylate-based coordination polymers were reported, and their magnetic properties were investigated. - Highlights: • Structures of three tetracarboxylate-based coordination polymers were reported. • Role of organic bases in metal–tetracarboxylate compounds was discussed. • Characters of V-shape and semi-rigidity for tetracarboxylate play a key role in crystal growth. • Their magnetic properties were investigated.

  18. A semi-interactive panorama based 3D reconstruction framework for indoor scenes

    NARCIS (Netherlands)

    Dang, T.K.; Worring, M.; Bui, T.D.

    2011-01-01

    We present a semi-interactive method for 3D reconstruction specialized for indoor scenes which combines computer vision techniques with efficient interaction. We use panoramas, popularly used for visualization of indoor scenes, but clearly not able to show depth, for their great field of view, as

  19. An algorithm to compute the square root of 3x3 positive definite matrix

    International Nuclear Information System (INIS)

    Franca, L.P.

    1988-06-01

    An efficient closed form to compute the square root of a 3 x 3 positive definite matrix is presented. The derivation employs the Cayley-Hamilton theorem avoiding calculation of eigenvectors. We show that evaluation of one eigenvalue of the square root matrix is needed and can not be circumvented. The algorithm is robust and efficient. (author) [pt

  20. Positivity for Convective Semi-discretizations

    KAUST Repository

    Fekete, Imre; Ketcheson, David I.; Loczi, Lajos

    2017-01-01

    We propose a technique for investigating stability properties like positivity and forward invariance of an interval for method-of-lines discretizations, and apply the technique to study positivity preservation for a class of TVD semi-discretizations

  1. Precipitation Processes developed during ARM (1997), TOGA COARE (1992), GATE (1974), SCSMEX (1998), and KWAJEX (1999), Consistent 2D, semi-3D and 3D Cloud Resolving Model Simulations

    Science.gov (United States)

    Tao, Wei-Kuo; Hou, A.; Atlas, R.; Starr, D.; Sud, Y.

    2003-01-01

    Real clouds and cloud systems are inherently three-dimensional (3D). Because of the limitations in computer resources, however, most cloud-resolving models (CRMs) today are still two-dimensional (2D). A few 3D CRMs have been used to study the response of clouds to large-scale forcing. In these 3D simulations, the model domain was small, and the integration time was 6 hours. The major objectives of this paper are: (1) to assess the performance of the super-parameterization technique (i.e. is 2D or semi-3D CRM appropriate for the super-parameterization?); (2) calculate and examine the surface energy (especially radiation) and water budgets; (3) identify the differences and similarities in the organization and entrainment rates of convection between simulated 2D and 3D cloud systems.

  2. Definition of new 3D invariants. Applications to pattern recognition problems with neural networks

    International Nuclear Information System (INIS)

    Proriol, J.

    1996-01-01

    We propose a definition of new 3D invariants. Usual pattern recognition methods use 2D descriptions of 3D objects, we propose a 2D approximation of the defined 3D invariants which can be used with neural networks to solve pattern recognition problems. We describe some methods to use the 2 D approximants. This work is an extension of previous 3D invariants used to solve some high energy physics problems. (author)

  3. Semi-recumbent position versus supine position for the prevention of ventilator-associated pneumonia in adults requiring mechanical ventilation.

    Science.gov (United States)

    Wang, Li; Li, Xiao; Yang, Zongxia; Tang, Xueli; Yuan, Qiang; Deng, Lijing; Sun, Xin

    2016-01-08

    trials did not provide complete data due to loss to follow-up. We judged all trials to be at high risk of bias. Semi-recumbent position (30º to 60º) versus supine position (0° to 10°) A semi-recumbent position (30º to 60º) significantly reduced the risk of clinically suspected VAP compared to a 0º to 10º supine position (eight trials, 759 participants, 14.3% versus 40.2%, RR 0.36; 95% CI 0.25 to 0.50; risk difference (RD) 25.7%; 95% CI 20.1% to 30.1%; GRADE: moderate quality evidence).There was no significant difference between the two positions in the following outcomes: microbiologically confirmed VAP (three trials, 419 participants, 12.6% versus 31.6%, RR 0.44; 95% CI 0.11 to 1.77; GRADE: very low quality evidence), ICU mortality (two trials, 307 participants, 29.8% versus 34.3%, RR 0.87; 95% CI 0.59 to 1.27; GRADE: low quality evidence), hospital mortality (three trials, 346 participants, 23.8% versus 27.6%, RR 0.84; 95% CI 0.59 to 1.20; GRADE: low quality evidence), length of ICU stay (three trials, 346 participants, MD -1.64 days; 95% CI -4.41 to 1.14 days; GRADE moderate quality evidence), length of hospital stay (two trials, 260 participants, MD -9.47 days; 95% CI -34.21 to 15.27 days; GRADE: very low quality evidence), duration of ventilation (four trials, 458 participants, MD -3.35 days; 95% CI -7.80 to 1.09 days), antibiotic use (three trials, 284 participants, 84.8% versus 84.2%, RR 1.00; 95% CI 0.97 to 1.03) and pressure ulcers (one trial, 221 participants, 28% versus 30%, RR 0.91; 95% CI 0.60 to 1.38; GRADE: low quality evidence). No other adverse events were reported. Semi-recumbent position (45°) versus 25° to 30° We found no statistically significant differences in the following prespecified outcomes: clinically suspected VAP (two trials, 91 participants, RR 0.74; 95% CI 0.35 to 1.56; GRADE: very low quality evidence), microbiologically confirmed VAP (one trial, 30 participants, RR 0.61; 95% CI 0.20 to 1.84: GRADE: very low quality evidence

  4. Semi-definite Programming: methods and algorithms for energy management

    International Nuclear Information System (INIS)

    Gorge, Agnes

    2013-01-01

    The present thesis aims at exploring the potentialities of a powerful optimization technique, namely Semi-definite Programming, for addressing some difficult problems of energy management. We pursue two main objectives. The first one consists of using SDP to provide tight relaxations of combinatorial and quadratic problems. A first relaxation, called 'standard' can be derived in a generic way but it is generally desirable to reinforce them, by means of tailor-made tools or in a systematic fashion. These two approaches are implemented on different models of the Nuclear Outages Scheduling Problem, a famous combinatorial problem. We conclude this topic by experimenting the Lasserre's hierarchy on this problem, leading to a sequence of semi-definite relaxations whose optimal values tends to the optimal value of the initial problem. The second objective deals with the use of SDP for the treatment of uncertainty. We investigate an original approach called 'distributionally robust optimization', that can be seen as a compromise between stochastic and robust optimization and admits approximations under the form of a SDP. We compare the benefits of this method w.r.t classical approaches on a demand/supply equilibrium problem. Finally, we propose a scheme for deriving SDP relaxations of MISOCP and we report promising computational results indicating that the semi-definite relaxation improves significantly the continuous relaxation, while requiring a reasonable computational effort. SDP therefore proves to be a promising optimization method that offers great opportunities for innovation in energy management. (author)

  5. 3D intrathoracic region definition and its application to PET-CT analysis

    Science.gov (United States)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2014-03-01

    Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.

  6. Persistent semi-metal-like nature of epitaxial perovskite CaIrO3 thin films

    International Nuclear Information System (INIS)

    Biswas, Abhijit; Jeong, Yoon Hee

    2015-01-01

    Strong spin-orbit coupled 5d transition metal based ABO 3 oxides, especially iridates, allow tuning parameters in the phase diagram and may demonstrate important functionalities, for example, by means of strain effects and symmetry-breaking, because of the interplay between the Coulomb interactions and strong spin-orbit coupling. Here, we have epitaxially stabilized high quality thin films of perovskite (Pv) CaIrO 3 . Film on the best lattice-matched substrate shows semi-metal-like characteristics. Intriguingly, imposing tensile or compressive strain on the film by altering the underlying lattice-mismatched substrates still maintains semi-metallicity with minute modification of the effective correlation as tensile (compressive) strain results in tiny increases (decreases) of the electronic bandwidth. In addition, magnetoresistance remains positive with a quadratic field dependence. This persistent semi-metal-like nature of Pv-CaIrO 3 thin films with minute changes in the effective correlation by strain may provide new wisdom into strong spin-orbit coupled 5d based oxide physics

  7. Evaluation of 3D Positioned Sound in Multimodal Scenarios

    DEFF Research Database (Denmark)

    Møller, Anders Kalsgaard

    present but interacts with the other meeting members using different virtual reality technologies. The thesis also dealt with a 3D sound system in trucks. it was investigated if 3D-sound could be used to give the truck driver an audible and lifelike experience of the cyclists’ position, in relation......This Ph.D. study has dealt with different binaural methods for implementing 3D sound in selected multimodal applications, with the purpose of evaluating the feasibility of using 3D sound in these applications. The thesis dealt with a teleconference application in which one person is not physically...

  8. Persistent semi-metal-like nature of epitaxial perovskite CaIrO{sub 3} thin films

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Abhijit; Jeong, Yoon Hee, E-mail: yhj@postech.ac.kr [Department of Physics, POSTECH, Pohang 790-784 (Korea, Republic of)

    2015-05-21

    Strong spin-orbit coupled 5d transition metal based ABO{sub 3} oxides, especially iridates, allow tuning parameters in the phase diagram and may demonstrate important functionalities, for example, by means of strain effects and symmetry-breaking, because of the interplay between the Coulomb interactions and strong spin-orbit coupling. Here, we have epitaxially stabilized high quality thin films of perovskite (Pv) CaIrO{sub 3}. Film on the best lattice-matched substrate shows semi-metal-like characteristics. Intriguingly, imposing tensile or compressive strain on the film by altering the underlying lattice-mismatched substrates still maintains semi-metallicity with minute modification of the effective correlation as tensile (compressive) strain results in tiny increases (decreases) of the electronic bandwidth. In addition, magnetoresistance remains positive with a quadratic field dependence. This persistent semi-metal-like nature of Pv-CaIrO{sub 3} thin films with minute changes in the effective correlation by strain may provide new wisdom into strong spin-orbit coupled 5d based oxide physics.

  9. Modeling And Position Control Of Scara Type 3D Printer

    Directory of Open Access Journals (Sweden)

    Ahmet Saygamp305n Ogulmuamp351

    2015-08-01

    Full Text Available In this work a scara robot type 3D printer system is dynamically modeled and position control of the system is realized. For this aim computer aided design model of three degrees of freedom robotic system is created using SolidWorks program then obtained model is exported to MATLABSimMechanics software for position control. Also mathematical model of servo motors used in robotic 3D printer system is included in control methodology to design proportional controllers. Uncontrolled and controlled position results are simulated and given in the form of the graphics.

  10. Semi-automatic registration of 3D orthodontics models from photographs

    Science.gov (United States)

    Destrez, Raphaël.; Treuillet, Sylvie; Lucas, Yves; Albouy-Kissi, Benjamin

    2013-03-01

    In orthodontics, a common practice used to diagnose and plan the treatment is the dental cast. After digitization by a CT-scan or a laser scanner, the obtained 3D surface models can feed orthodontics numerical tools for computer-aided diagnosis and treatment planning. One of the pre-processing critical steps is the 3D registration of dental arches to obtain the occlusion of these numerical models. For this task, we propose a vision based method to automatically compute the registration based on photos of patient mouth. From a set of matched singular points between two photos and the dental 3D models, the rigid transformation to apply to the mandible to be in contact with the maxillary may be computed by minimizing the reprojection errors. During a precedent study, we established the feasibility of this visual registration approach with a manual selection of singular points. This paper addresses the issue of automatic point detection. Based on a priori knowledge, histogram thresholding and edge detection are used to extract specific points in 2D images. Concurrently, curvatures information detects 3D corresponding points. To improve the quality of the final registration, we also introduce a combined optimization of the projection matrix with the 2D/3D point positions. These new developments are evaluated on real data by considering the reprojection errors and the deviation angles after registration in respect to the manual reference occlusion realized by a specialist.

  11. Efficient Semi-Automatic 3D Segmentation for Neuron Tracing in Electron Microscopy Images

    Science.gov (United States)

    Jones, Cory; Liu, Ting; Cohan, Nathaniel Wood; Ellisman, Mark; Tasdizen, Tolga

    2015-01-01

    0.1. Background In the area of connectomics, there is a significant gap between the time required for data acquisition and dense reconstruction of the neural processes contained in the same dataset. Automatic methods are able to eliminate this timing gap, but the state-of-the-art accuracy so far is insufficient for use without user corrections. If completed naively, this process of correction can be tedious and time consuming. 0.2. New Method We present a new semi-automatic method that can be used to perform 3D segmentation of neurites in EM image stacks. It utilizes an automatic method that creates a hierarchical structure for recommended merges of superpixels. The user is then guided through each predicted region to quickly identify errors and establish correct links. 0.3. Results We tested our method on three datasets with both novice and expert users. Accuracy and timing were compared with published automatic, semi-automatic, and manual results. 0.4. Comparison with Existing Methods Post-automatic correction methods have also been used in [1] and [2]. These methods do not provide navigation or suggestions in the manner we present. Other semi-automatic methods require user input prior to the automatic segmentation such as [3] and [4] and are inherently different than our method. 0.5. Conclusion Using this method on the three datasets, novice users achieved accuracy exceeding state-of-the-art automatic results, and expert users achieved accuracy on par with full manual labeling but with a 70% time improvement when compared with other examples in publication. PMID:25769273

  12. A semi-automated 2D/3D marker-based registration algorithm modelling prostate shrinkage during radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Budiharto, Tom; Slagmolen, Pieter; Hermans, Jeroen; Maes, Frederik; Verstraete, Jan; Heuvel, Frank Van den; Depuydt, Tom; Oyen, Raymond; Haustermans, Karin

    2009-01-01

    Background and purpose: Currently, most available patient alignment tools based on implanted markers use manual marker matching and rigid registration transformations to measure the needed translational shifts. To quantify the particular effect of prostate gland shrinkage, implanted gold markers were tracked during a course of radiotherapy including an isotropic scaling factor to model prostate shrinkage. Materials and methods: Eight patients with prostate cancer had gold markers implanted transrectally and seven were treated with (neo) adjuvant androgen deprivation therapy. After patient alignment to skin tattoos, orthogonal electronic portal images (EPIs) were taken. A semi-automated 2D/3D marker-based registration was performed to calculate the necessary couch shifts. The registration consists of a rigid transformation combined with an isotropic scaling to model prostate shrinkage. Results: The inclusion of an isotropic shrinkage model in the registration algorithm cancelled the corresponding increase in registration error. The mean scaling factor was 0.89 ± 0.09. For all but two patients, a decrease of the isotropic scaling factor during treatment was observed. However, there was almost no difference in the translation offset between the manual matching of the EPIs to the digitally reconstructed radiographs and the semi-automated 2D/3D registration. A decrease in the intermarker distance was found correlating with prostate shrinkage rather than with random marker migration. Conclusions: Inclusion of shrinkage in the registration process reduces registration errors during a course of radiotherapy. Nevertheless, this did not lead to a clinically significant change in the proposed table translations when compared to translations obtained with manual marker matching without a scaling correction

  13. The King-Devick (K-D) test and concussion diagnosis in semi-professional rugby union players.

    Science.gov (United States)

    Molloy, John H; Murphy, Ian; Gissane, Conor

    2017-08-01

    To determine the utility of the King-Devick (K-D) test in identifying sports-related concussion in semi-professional rugby players. Descriptive cohort study. 176 male players were recruited from a semi-professional rugby union competition in New Zealand (NZ). Baseline K-D scores were obtained in the pre-season. Post-match K-D and Pitch Side Concussion Assessment Version 2 (PSCA2) scores were obtained in those with suspected concussion. Post-match K-D scores were also administered to selected control players. 19 concussions in 18 players were analysed. In addition, 33 controls were used for analysis. A positive K-D test was identified in 53% of players with concussion post-match. Conversely, a positive test was identified in 33% of controls. The sensitivity and specificity of the K-D test was calculated as 53% and 69% respectively. The positive predictive value and negative predictive value was 48% and 73% respectively. The PSCA2 correctly identified 74% of concussions. The K-D test identified 3 cases not identified by the PSCA2. When the PSCA2 and K-D were combined, 89% of concussions were correctly identified. The K-D test does not appear to be effective if used as a stand-alone test for the diagnosis of concussion. However, if used alongside current side-line cognitive and balance tests, it may assist in more accurately diagnosing sports-related concussion. Further research should look to utilise the K-D test in in-match protocols to establish if this improves the diagnostic accuracy of in-match protocols for sports-related concussion. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. 32 CFR 185.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Definitions. 185.3 Section 185.3 National... AUTHORITIES (MSCA) § 185.3 Definitions. Attack. Any attack or series of attacks by an enemy of the United... contingency planning (and MSCA operations when ordered) by all DoD Components within an assigned geographic...

  15. 3D visualization reduces operating time when compared to high-definition 2D in laparoscopic liver resection: a case-matched study.

    Science.gov (United States)

    Velayutham, Vimalraj; Fuks, David; Nomi, Takeo; Kawaguchi, Yoshikuni; Gayet, Brice

    2016-01-01

    To evaluate the effect of three-dimensional (3D) visualization on operative performance during elective laparoscopic liver resection (LLR). Major limitations of conventional laparoscopy are lack of depth perception and tactile feedback. Introduction of robotic technology, which employs 3D imaging, has removed only one of these technical obstacles. Despite the significant advantages claimed, 3D systems have not been widely accepted. In this single institutional study, 20 patients undergoing LLR by high-definition 3D laparoscope between April 2014 and August 2014 were matched to a retrospective control group of patients who underwent LLR by two-dimensional (2D) laparoscope. The number of patients who underwent major liver resection was 5 (25%) in the 3D group and 10 (25%) in the 2D group. There was no significant difference in contralateral wedge resection or combined resections between the 3D and 2D groups. There was no difference in the proportion of patients undergoing previous abdominal surgery (70 vs. 77%, p = 0.523) or previous hepatectomy (20 vs. 27.5%, p = 0.75). The operative time was significantly shorter in the 3D group when compared to 2D (225 ± 109 vs. 284 ± 71 min, p = 0.03). There was no significant difference in blood loss in the 3D group when compared to 2D group (204 ± 226 in 3D vs. 252 ± 349 ml in 2D group, p = 0.291). The major complication rates were similar, 5% (1/20) and 7.5% (3/40), respectively, (p ≥ 0.99). 3D visualization may reduce the operating time compared to high-definition 2D. Further large studies, preferably prospective randomized control trials are required to confirm this.

  16. New Position Algorithms for the 3-D CZT Drift Detector

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Kuvvetli, Irfan

    2017-01-01

    The 3-D position sensitive CZT detector for high-energy astrophysics developed at DTU has been investigated with a digitizer readout system. The 3-D CZT detector is based on the CZT drift-strip detector principle and was fabricated using a REDLEN CZT crystal (20 mm x 20 mm x 5 mm). The detector...... at 662 keV. The analysis required development of novel position determination algorithms which are the subject of this paper. Using the digitizer readout, we demonstrate improved position determination compared to the previous read out system based on analog electronics. Position resolutions of 0.4-mm....... These characteristics are very important for a high-energy spectral-imager suitable for use in advanced Compton telescopes, or as focal detector for new hard X-ray and soft gamma-ray focusing telescopes or in polarimeter instrumentation. CZT detectors are attractive for these applications since they offer relatively...

  17. Combining heterogeneous features for colonic polyp detection in CTC based on semi-definite programming

    Science.gov (United States)

    Wang, Shijun; Yao, Jianhua; Petrick, Nicholas A.; Summers, Ronald M.

    2009-02-01

    Colon cancer is the second leading cause of cancer-related deaths in the United States. Computed tomographic colonography (CTC) combined with a computer aided detection system provides a feasible combination for improving colonic polyps detection and increasing the use of CTC for colon cancer screening. To distinguish true polyps from false positives, various features extracted from polyp candidates have been proposed. Most of these features try to capture the shape information of polyp candidates or neighborhood knowledge about the surrounding structures (fold, colon wall, etc.). In this paper, we propose a new set of shape descriptors for polyp candidates based on statistical curvature information. These features, called histogram of curvature features, are rotation, translation and scale invariant and can be treated as complementing our existing feature set. Then in order to make full use of the traditional features (defined as group A) and the new features (group B) which are highly heterogeneous, we employed a multiple kernel learning method based on semi-definite programming to identify an optimized classification kernel based on the combined set of features. We did leave-one-patient-out test on a CTC dataset which contained scans from 50 patients (with 90 6-9mm polyp detections). Experimental results show that a support vector machine (SVM) based on the combined feature set and the semi-definite optimization kernel achieved higher FROC performance compared to SVMs using the two groups of features separately. At a false positive per patient rate of 7, the sensitivity on 6-9mm polyps using the combined features improved from 0.78 (Group A) and 0.73 (Group B) to 0.82 (p<=0.01).

  18. Accuracy and reproducibility of aortic annular measurements obtained from echocardiographic 3D manual and semi-automated software analyses in patients referred for transcatheter aortic valve implantation: implication for prosthesis size selection.

    Science.gov (United States)

    Stella, Stefano; Italia, Leonardo; Geremia, Giulia; Rosa, Isabella; Ancona, Francesco; Marini, Claudia; Capogrosso, Cristina; Giglio, Manuela; Montorfano, Matteo; Latib, Azeem; Margonato, Alberto; Colombo, Antonio; Agricola, Eustachio

    2018-02-06

    A 3D transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced. The system automatically configures a geometric model of the aortic root and performs quantitative analysis of these structures. We compared the measurements of the aortic annulus (AA) obtained by semi-automated 3D-TOE quantitative software and manual analysis vs. multislice computed tomography (MSCT) ones. One hundred and seventy-five patients (mean age 81.3 ± 6.3 years, 77 men) who underwent both MSCT and 3D-TOE for annulus assessment before transcatheter aortic valve implantation were analysed. Hypothetical prosthetic valve sizing was evaluated using the 3D manual, semi-automated measurements using manufacturer-recommended CT-based sizing algorithm as gold standard. Good correlation between 3D-TOE methods vs. MSCT measurements was found, but the semi-automated analysis demonstrated slightly better correlations for AA major diameter (r = 0.89), perimeter (r = 0.89), and area (r = 0.85) (all P 3D methods underestimated the MSCT measurements, but semi-automated measurements showed narrower limits of agreement and lesser bias than manual measurements for most of AA parameters. On average, 3D-TOE semi-automated major diameter, area, and perimeter underestimated the respective MSCT measurements by 7.4%, 3.5%, and 4.4%, respectively, whereas minor diameter was overestimated by 0.3%. Moderate agreement for valve sizing for both 3D-TOE techniques was found: Kappa agreement 0.5 for both semi-automated and manual analysis. Interobserver and intraobserver agreements for the AA measurements were excellent for both techniques (intraclass correlation coefficients for all parameters >0.80). The 3D-TOE semi-automated analysis of AA is feasible and reliable and can be used in clinical practice as an alternative to MSCT for AA assessment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please

  19. Inertial Pocket Navigation System: Unaided 3D Positioning

    Directory of Open Access Journals (Sweden)

    Estefania Munoz Diaz

    2015-04-01

    Full Text Available Inertial navigation systems use dead-reckoning to estimate the pedestrian’s position. There are two types of pedestrian dead-reckoning, the strapdown algorithm and the step-and-heading approach. Unlike the strapdown algorithm, which consists of the double integration of the three orthogonal accelerometer readings, the step-and-heading approach lacks the vertical displacement estimation. We propose the first step-and-heading approach based on unaided inertial data solving 3D positioning. We present a step detector for steps up and down and a novel vertical displacement estimator. Our navigation system uses the sensor introduced in the front pocket of the trousers, a likely location of a smartphone. The proposed algorithms are based on the opening angle of the leg or pitch angle. We analyzed our step detector and compared it with the state-of-the-art, as well as our already proposed step length estimator. Lastly, we assessed our vertical displacement estimator in a real-world scenario. We found that our algorithms outperform the literature step and heading algorithms and solve 3D positioning using unaided inertial data. Additionally, we found that with the pitch angle, five activities are distinguishable: standing, sitting, walking, walking up stairs and walking down stairs. This information complements the pedestrian location and is of interest for applications, such as elderly care.

  20. Inertial Pocket Navigation System: Unaided 3D Positioning

    Science.gov (United States)

    Munoz Diaz, Estefania

    2015-01-01

    Inertial navigation systems use dead-reckoning to estimate the pedestrian's position. There are two types of pedestrian dead-reckoning, the strapdown algorithm and the step-and-heading approach. Unlike the strapdown algorithm, which consists of the double integration of the three orthogonal accelerometer readings, the step-and-heading approach lacks the vertical displacement estimation. We propose the first step-and-heading approach based on unaided inertial data solving 3D positioning. We present a step detector for steps up and down and a novel vertical displacement estimator. Our navigation system uses the sensor introduced in the front pocket of the trousers, a likely location of a smartphone. The proposed algorithms are based on the opening angle of the leg or pitch angle. We analyzed our step detector and compared it with the state-of-the-art, as well as our already proposed step length estimator. Lastly, we assessed our vertical displacement estimator in a real-world scenario. We found that our algorithms outperform the literature step and heading algorithms and solve 3D positioning using unaided inertial data. Additionally, we found that with the pitch angle, five activities are distinguishable: standing, sitting, walking, walking up stairs and walking down stairs. This information complements the pedestrian location and is of interest for applications, such as elderly care. PMID:25897501

  1. Mathematical Definition, Mapping, and Detection of (Anti)Fragility

    OpenAIRE

    Taleb, Nassim N.; Douady, Raphael

    2012-01-01

    URL des Documents de travail : http://centredeconomiesorbonne.univ-paris1.fr/documents-de-travail/; Documents de travail du Centre d'Economie de la Sorbonne 2014.93 - ISSN : 1955-611X; We provide a mathematical definition of fragility and antifragility as negative or positive sensitivity to a semi-measure of dispersion and volatility (a variant of negative or positive "vega") and examine the link to nonlinear effects. We integrate model error (and biases) into the fragile or antifragile conte...

  2. A Robust Incomplete Factorization Preconditioner for Positive Definite Matrices

    Czech Academy of Sciences Publication Activity Database

    Benzi, M.; Tůma, Miroslav

    2003-01-01

    Roč. 10, - (2003), s. 385-400 ISSN 1070-5325 R&D Projects: GA AV ČR IAA2030801; GA AV ČR IAA1030103 Institutional research plan: AV0Z1030915 Keywords : sparse linear systems * positive definite matrices * preconditioned conjugate gradient s * incomplete factorization * A-orthogonalization * SAINV Subject RIV: BA - General Mathematics Impact factor: 1.042, year: 2003

  3. 32 CFR 168a.3 - Definition.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Definition. 168a.3 Section 168a.3 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DEFENSE CONTRACTING NATIONAL DEFENSE SCIENCE AND ENGINEERING GRADUATE FELLOWSHIPS § 168a.3 Definition. Sponsoring Agency. A DoD Component or an...

  4. 3D positioning scheme exploiting nano-scale IR-UWB orthogonal pulses.

    Science.gov (United States)

    Kim, Nammoon; Kim, Youngok

    2011-10-04

    In these days, the development of positioning technology for realizing ubiquitous environments has become one of the most important issues. The Global Positioning System (GPS) is a well-known positioning scheme, but it is not suitable for positioning in in-door/building environments because it is difficult to maintain line-of-sight condition between satellites and a GPS receiver. To such problem, various positioning methods such as RFID, WLAN, ZigBee, and Bluetooth have been developed for indoor positioning scheme. However, the majority of positioning schemes are focused on the two-dimension positioning even though three-dimension (3D) positioning information is more useful especially in indoor applications, such as smart space, U-health service, context aware service, etc. In this paper, a 3D positioning system based on mutually orthogonal nano-scale impulse radio ultra-wideband (IR-UWB) signals and cross array antenna is proposed. The proposed scheme uses nano-scale IR-UWB signals providing fine time resolution and high-resolution multiple signal specification algorithm for the time-of-arrival and the angle-of-arrival estimation. The performance is evaluated over various IEEE 802.15.4a channel models, and simulation results show the effectiveness of proposed scheme.

  5. Positive Eigenvalues of Generalized Words in Two Hermitian Positive Definite Matrices

    OpenAIRE

    Hillar, Christopher; Johnson, Charles R.

    2005-01-01

    We define a word in two positive definite (complex Hermitian) matrices $A$ and $B$ as a finite product of real powers of $A$ and $B$. The question of which words have only positive eigenvalues is addressed. This question was raised some time ago in connection with a long-standing problem in theoretical physics, and it was previously approached by the authors for words in two real positive definite matrices with positive integral exponents. A large class of words that do guarantee positive eig...

  6. Three dimensional variability in patient positioning using bite block immobilization in 3D-conformal radiation treatment for ENT-tumors

    International Nuclear Information System (INIS)

    Willner, Jochen; Haedinger, Ulrich; Neumann, Michael; Schwab, Franz J.; Bratengeier, Klaus; Flentje, Michael

    1997-01-01

    systematic variations were less than 4 mm. Conclusions: The presented individualized bite block immobilization device provides an accurate and reproducible patient positioning for 3D-conformal radiation therapy in the head and neck. Random and systematic deviations in each of the three directions are in the range of ±4 mm (2 SD, comprising 95% of the deviations) and are within the range or even less than deviations described for most thermoplastic or PVC-mask fixation devices. These deviations should be taken into account during definition of planning target volume in head and neck tumors

  7. Novel, high-definition 3-D endoscopy system with real-time compression communication system to aid diagnoses and treatment between hospitals in Thailand.

    Science.gov (United States)

    Uemura, Munenori; Kenmotsu, Hajime; Tomikawa, Morimasa; Kumashiro, Ryuichi; Yamashita, Makoto; Ikeda, Testuo; Yamashita, Hiromasa; Chiba, Toshio; Hayashi, Koichi; Sakae, Eiji; Eguchi, Mitsuo; Fukuyo, Tsuneo; Chittmittrapap, Soottiporn; Navicharern, Patpong; Chotiwan, Pornarong; Pattana-Arum, Jirawat; Hashizume, Makoto

    2015-05-01

    Traditionally, laparoscopy has been based on 2-D imaging, which represents a considerable challenge. As a result, 3-D visualization technology has been proposed as a way to better facilitate laparoscopy. We compared the latest 3-D systems with high-end 2-D monitors to validate the usefulness of new systems for endoscopic diagnoses and treatment in Thailand. We compared the abilities of our high-definition 3-D endoscopy system with real-time compression communication system with a conventional high-definition (2-D) endoscopy system by asking health-care staff to complete tasks. Participants answered questionnaires and whether procedures were easier using our system or the 2-D endoscopy system. Participants were significantly faster at suture insertion with our system (34.44 ± 15.91 s) than with the 2-D system (52.56 ± 37.51 s) (P < 0.01). Most surgeons thought that the 3-D system was good in terms of contrast, brightness, perception of the anteroposterior position of the needle, needle grasping, inserting the needle as planned, and needle adjustment during laparoscopic surgery. Several surgeons highlighted the usefulness of exposing and clipping the bile duct and gallbladder artery, as well as dissection from the liver bed during laparoscopic surgery. In an image-transfer experiment with RePure-L®, participants at Rajavithi Hospital could obtain reconstructed 3-D images that were non-inferior to conventional images from Chulalongkorn University Hospital (10 km away). These data suggest that our newly developed system could be of considerable benefit to the health-care system in Thailand. Transmission of moving endoscopic images from a center of excellence to a rural hospital could help in the diagnosis and treatment of various diseases. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  8. 3D DSA findings of uterine artery and its optimal projection position

    International Nuclear Information System (INIS)

    Lu Weifu; Zhang Aiwu; Zhou Chunze; Lu Dong; Xiao Jingkun; Wang Weiyu; Zhang Xingming; Zhang Zhengfeng; Hou Changlong

    2011-01-01

    Objective: to observe the origin site, anatomic features of uterine artery with 3D DSA and to discuss the optimal projection position in order to improve the success rate of super-selective catheterization of uterine artery. Methods: Prospective pelvic angiography was performed in 42 adult females (a total of 84 uterine arteries). 3D DSA was carried out with 206 ° rotation. 3D reconstruction of the obtained images was performed and the angiographic manifestations of the uterine artery were analyzed. The optimal projection position for the displaying of uterine artery was discussed. The quality of images obtained with the projection angle of 15 °-25 °, 25 °-35 ° and 35 °-45 ° was determined and the results were compared with each other. Results: The orifices of all 84 uterine arteries could be well demonstrated on 3D DSA images. The uterine artery was originated from the anterior trunk of internal iliac artery (n=58, 69%), from main stem of internal iliac artery (n=16, 19.1%), from internal pudenda artery (n=8, 9.5%) and from inferior gluteal artery (n=2, 2.4%). The best projection position to show the opening and route of the uterine artery was contralateral oblique view of 25-35 degrees (P<0.05). Conclusion: 3D DSA can clearly display the anatomy of the uterine artery, which is very helpful for the management of super-selective catheterization of uterine artery. The optimal projection position for uterine artery is contralateral oblique view of 25-35 degrees. (authors)

  9. Volume definition system for treatment planning

    International Nuclear Information System (INIS)

    Alakuijala, Jyrki; Pekkarinen, Ari; Puurunen, Harri

    1997-01-01

    Purpose: Volume definition is a difficult and time consuming task in 3D treatment planning. We have studied a systems approach for constructing an efficient and reliable set of tools for volume definition. Our intent is to automate body outline, air cavities and bone volume definition and accelerate definition of other anatomical structures. An additional focus is on assisting in definition of CTV and PTV. The primary goals of this work are to cut down the time used in contouring and to improve the accuracy of volume definition. Methods: We used the following tool categories: manual, semi-automatic, automatic, structure management, target volume definition, and visualization tools. The manual tools include mouse contouring tools with contour editing possibilities and painting tools with a scaleable circular brush and an intelligent brush. The intelligent brush adapts its shape to CT value boundaries. The semi-automatic tools consist of edge point chaining, classical 3D region growing of single segment and competitive volume growing of multiple segments. We tuned the volume growing function to take into account both local and global region image values, local volume homogeneity, and distance. Heuristic seeding followed with competitive volume growing finds the body outline, couch and air automatically. The structure management tool stores ICD-O coded structures in a database. The codes have predefined volume growing parameters and thus are able to accommodate the volume growing dissimilarity function for different volume types. The target definition tools include elliptical 3D automargin for CTV to PTV transformation and target volume interpolation and extrapolation by distance transform. Both the CTV and the PTV can overlap with anatomical structures. Visualization tools show the volumes as contours or color wash overlaid on an image and displays voxel rendering or translucent triangle mesh rendering in 3D. Results: The competitive volume growing speeds up the

  10. 3D positioning scheme exploiting nano-scale IR-UWB orthogonal pulses

    Directory of Open Access Journals (Sweden)

    Kim Nammoon

    2011-01-01

    Full Text Available Abstract In these days, the development of positioning technology for realizing ubiquitous environments has become one of the most important issues. The Global Positioning System (GPS is a well-known positioning scheme, but it is not suitable for positioning in in-door/building environments because it is difficult to maintain line-of-sight condition between satellites and a GPS receiver. To such problem, various positioning methods such as RFID, WLAN, ZigBee, and Bluetooth have been developed for indoor positioning scheme. However, the majority of positioning schemes are focused on the two-dimension positioning even though three-dimension (3D positioning information is more useful especially in indoor applications, such as smart space, U-health service, context aware service, etc. In this paper, a 3D positioning system based on mutually orthogonal nano-scale impulse radio ultra-wideband (IR-UWB signals and cross array antenna is proposed. The proposed scheme uses nano-scale IR-UWB signals providing fine time resolution and high-resolution multiple signal specification algorithm for the time-of-arrival and the angle-of-arrival estimation. The performance is evaluated over various IEEE 802.15.4a channel models, and simulation results show the effectiveness of proposed scheme.

  11. Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom

    International Nuclear Information System (INIS)

    Jang, Eun Sung; Kang, Soo Man; Lee, Chul Soo

    2009-01-01

    The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. The difference between mean detection error and standard deviation are as follows; lateral 0.4±0.3 mm, longitudinal 0.6±0.5 mm, vertical 0.4±0.2 mm which all within 0-10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3±0.1, 0.5±0.1, and 0.3±0.1 mm. The mean detection errors by longitudinal shift between 20-40 mm are 0.4±0.3 in lateral, 0.6±0.5 in longitudinal, 0.5±0.3 in vertical direction. The detection errors are all within range of 0.3-0.5 mm. Residual errors are within 0.2-0.5 mm. Each values are mean values based on 3 tests. Phantom is based on treatment couch shift and error within the average 5 mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  12. Particle based 3D modeling of positive streamer inception

    NARCIS (Netherlands)

    H.J. Teunissen (Jannis)

    2012-01-01

    htmlabstractIn this report we present a particle based 3D model for the study of streamer inception near positive electrodes in air. The particle code is of the PIC-MCC type and an electrode is included using the charge simulation method. An algorithm for the adaptive creation of super-particles is

  13. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  14. Structured-Light Based 3d Laser Scanning of Semi-Submerged Structures

    Science.gov (United States)

    van der Lucht, J.; Bleier, M.; Leutert, F.; Schilling, K.; Nüchter, A.

    2018-05-01

    In this work we look at 3D acquisition of semi-submerged structures with a triangulation based underwater laser scanning system. The motivation is that we want to simultaneously capture data above and below water to create a consistent model without any gaps. The employed structured light scanner consist of a machine vision camera and a green line laser. In order to reconstruct precise surface models of the object it is necessary to model and correct for the refraction of the laser line and camera rays at the water-air boundary. We derive a geometric model for the refraction at the air-water interface and propose a method for correcting the scans. Furthermore, we show how the water surface is directly estimated from sensor data. The approach is verified using scans captured with an industrial manipulator to achieve reproducible scanner trajectories with different incident angles. We show that the proposed method is effective for refractive correction and that it can be applied directly to the raw sensor data without requiring any external markers or targets.

  15. STRUCTURED-LIGHT BASED 3D LASER SCANNING OF SEMI-SUBMERGED STRUCTURES

    Directory of Open Access Journals (Sweden)

    J. van der Lucht

    2018-05-01

    Full Text Available In this work we look at 3D acquisition of semi-submerged structures with a triangulation based underwater laser scanning system. The motivation is that we want to simultaneously capture data above and below water to create a consistent model without any gaps. The employed structured light scanner consist of a machine vision camera and a green line laser. In order to reconstruct precise surface models of the object it is necessary to model and correct for the refraction of the laser line and camera rays at the water-air boundary. We derive a geometric model for the refraction at the air-water interface and propose a method for correcting the scans. Furthermore, we show how the water surface is directly estimated from sensor data. The approach is verified using scans captured with an industrial manipulator to achieve reproducible scanner trajectories with different incident angles. We show that the proposed method is effective for refractive correction and that it can be applied directly to the raw sensor data without requiring any external markers or targets.

  16. Pharmacophore definition and 3D searches.

    Science.gov (United States)

    Langer, T; Wolber, G

    2004-12-01

    The most common pharmacophore building concepts based on either 3D structure of the target or ligand information are discussed together with the application of such models as queries for 3D database search. An overview of the key techniques available on the market is given and differences with respect to algorithms used and performance obtained are highlighted. Pharmacophore modelling and 3D database search are shown to be successful tools for enriching screening experiments aimed at the discovery of novel bio-active compounds.: © 2004 Elsevier Ltd . All rights reserved.

  17. POSITIVE SOLUTIONS TO SEMI-LINEAR SECOND-ORDER ORDINARY DIFFERENTIAL EQUATIONS IN BANACH SPACE

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In this paper,we study the existence of positive periodic solution to some second- order semi-linear differential equation in Banach space.By the fixed point index theory, we prove that the semi-linear differential equation has two positive periodic solutions.

  18. New Position Algorithms for the 3-D CZT Drift Detector

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.

    2017-06-01

    The 3-D position sensitive CZT detector for high-energy astrophysics developed at DTU has been investigated with a digitizer readout system. The 3-D CZT detector is based on the CZT drift-strip detector principle and was fabricated using a REDLEN CZT crystal (20 mm × 20 mm × 5 mm). The detector contains 12 drift cells, each comprising one collecting anode strip with four drift strips, biased such that the electrons are focused and collected by the anode strips. Three-dimensional position determination is achieved using the anode strip signals, the drift-strip signals, and the signals from ten cathode strips. For the characterization work, we used a DAQ system with a 16 channels 250-MHz 14-b digitizer, SIS3316. It allowed us to analyze the pulse shapes of the signals from four detector cells at a time. The 3-D CZT setup was characterized with a finely collimated radioactive source of 137Cs at 662 keV. The analysis required development of novel position determination algorithms which are the subject of this paper. Using the digitizer readout, we demonstrate improved position determination compared to the previous read out system based on analog electronics. Position resolutions of 0.4-mm full width at half maximum (FWHM) in the x-, y-, and z-directions were achieved and the energy resolution was 7.2-keV FWHM at 662 keV. The timing information allows identification of multiple interaction events within one detector cell, e.g., Compton scattering followed by photoelectric absorption. These characteristics are very important for a high-energy spectral-imager suitable for use in advanced Compton telescopes, or as focal detector for new hard X-ray and soft γ-ray focusing telescopes or in polarimeter instrumentation. CZT detectors are attractive for these applications since they offer relatively high-quantum efficiency. From a technical point of view it is advantageous that their cooling requirements are modest.

  19. Computerized diagnostic data analysis and 3-D visualization

    International Nuclear Information System (INIS)

    Schuhmann, D.; Haubner, M.; Krapichler, C.; Englmeier, K.H.; Seemann, M.; Schoepf, U.J.; Gebicke, K.; Reiser, M.

    1998-01-01

    Purpose: To survey methods for 3D data visualization and image analysis which can be used for computer based diagnostics. Material and methods: The methods available are explained in short terms and links to the literature are presented. Methods which allow basic manipulation of 3D data are windowing, rotation and clipping. More complex methods for visualization of 3D data are multiplanar reformation, volume projections (MIP, semi-transparent projections) and surface projections. Methods for image analysis comprise local data transformation (e.g. filtering) and definition and application of complex models (e.g. deformable models). Results: Volume projections produce an impression of the 3D data set without reducing the data amount. This supports the interpretation of the 3D data set and saves time in comparison to any investigation which requires examination of all slice images. More advanced techniques for visualization, e.g. surface projections and hybrid rendering visualize anatomical information to a very detailed extent, but both techniques require the segmentation of the structures of interest. Image analysis methods can be used to extract these structures (e.g. an organ) from the image data. Discussion: At the present time volume projections are robust and fast enough to be used routinely. Surface projections can be used to visualize complex and presegmented anatomical features. (orig.) [de

  20. 3D Surgical Simulation

    Science.gov (United States)

    Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2009-01-01

    This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intra-operative guidance. The system provides further intra-operative assistance with the help of a computer display showing jaw positions and 3D positioning guides updated in real-time during the surgical procedure. The CAS system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training and assessing the difficulties of the surgical procedures prior to the surgery. CAS has the potential to make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. Supported by NIDCR DE017727, and DE018962 PMID:20816308

  1. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    Directory of Open Access Journals (Sweden)

    Georgios Kouveliotis

    2017-01-01

    Full Text Available Introduction: Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case: A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heatcured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion: Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  2. A 3D Printed Linear Pneumatic Actuator for Position, Force and Impedance Control

    Directory of Open Access Journals (Sweden)

    Jeremy Krause

    2018-05-01

    Full Text Available Although 3D printing has the potential to provide greater customization and to reduce the costs of creating actuators for industrial applications, the 3D printing of actuators is still a relatively new concept. We have developed a pneumatic actuator with 3D-printed parts and placed sensors for position and force control. So far, 3D printing has been used to create pneumatic actuators of the bellows type, thus having a limited travel distance, utilizing low pressures for actuation and being capable of only limited force production and response rates. In contrast, our actuator is linear with a large travel distance and operating at a relatively higher pressure, thus providing great forces and response rates, and this the main novelty of the work. We demonstrate solutions to key challenges that arise during the design and fabrication of 3D-printed linear actuators. These include: (1 the strategic use of metallic parts in high stress areas (i.e., the piston rod; (2 post-processing of the inner surface of the cylinder for smooth finish; (3 piston head design and seal placement for strong and leak-proof action; and (4 sensor choice and placement for position and force control. A permanent magnet placed in the piston head is detected using Hall effect sensors placed along the length of the cylinder to measure the position, and pressure sensors placed at the supply ports were used for force measurement. We demonstrate the actuator performing position, force and impedance control. Our work has the potential to open new avenues for creating less expensive, customizable and capable actuators for industrial and other applications.

  3. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  4. Semi-industrial scale (30 m3) fed-batch fermentation for the production of D-lactate by Escherichia coli strain HBUT-D15.

    Science.gov (United States)

    Fu, Xiangmin; Wang, Yongze; Wang, Jinhua; Garza, Erin; Manow, Ryan; Zhou, Shengde

    2017-02-01

    D(-)-lactic acid is needed for manufacturing of stereo-complex poly-lactic acid polymer. Large scale D-lactic acid fermentation, however, has yet to be demonstrated. A genetically engineered Escherichia coli strain, HBUT-D, was adaptively evolved in a 15% calcium lactate medium for improved lactate tolerance. The resulting strain, HBUT-D15, was tested at a lab scale (7 L) by fed-batch fermentation with up to 200 g L -1 of glucose, producing 184-191 g L -1 of D-lactic acid, with a volumetric productivity of 4.38 g L -1  h -1 , a yield of 92%, and an optical purity of 99.9%. The HBUT-D15 was then evaluated at a semi-industrial scale (30 m 3 ) via fed-batch fermentation with up to 160 g L -1 of glucose, producing 146-150 g L -1 of D-lactic acid, with a volumetric productivity of 3.95-4.29 g L -1  h -1 , a yield of 91-94%, and an optical purity of 99.8%. These results are comparable to that of current industrial scale L(+)-lactic acid fermentation.

  5. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  6. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  7. A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Schutyser, F.A.C.; Barth, E.L.; Groeve, P. De; Mey, A. De

    2006-01-01

    The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal

  8. Importance of protocol target definition on the ability to spare normal tissue: An IMRT and 3D-CRT planning comparison for intraorbital tumors

    International Nuclear Information System (INIS)

    Hein, Patrick A.; Gladstone, David J.; Bellerive, Marc R.; Hug, Eugen B.

    2005-01-01

    were fulfilled in all cases (5/5) with 3D-CRT and IMRT. Using the protocol criteria, lens sparing was achieved only for two tumor sites (retrobulbar and lateral position) with either planning technique. Mean lens doses were 8.5 and 10.4 Gy for 3D-CRT and 7.5 and 13.2 Gy for IMRT, respectively. The mean lens doses for the other three tumor locations averaged 26.8 Gy. IMRT plans reduced the lens dose in four of five cases by an average of 2.6 Gy compared with 3D-CRT. Modified target protocol prescription markedly reduced mean lens doses by 23-50% and by as much as 18 Gy. Recorded mean lens doses after protocol modification were 26% lower using IMRT plans compared with 3D-CRT. The cold spot as a result of the relaxed volume coverage requirements was within 2% of the original protocol criteria and located at the edge of the PTV, outside the CTV. Compared with 3D-CRT, IMRT resulted in an increase of brain volume receiving 10% (V10) and 20% (V20) of the prescribed dose. Conclusion: Strict adherence to IRS-V protocol criteria prohibits at present lens sparing within compliance criteria for the majority of intraorbital tumor locations because of protocol-specific CTV and PTV target definitions. Changing protocol definitions by prescribing to the volume rather than to a dose constraint, IMRT planning significantly reduced lens doses. This was not accomplished to the same degree with 3D-CRT. Our study underlines the importance of appropriate selection of planning objectives to maximize the specific capabilities and advantages of IMRT in terms of sufficient target coverage and simultaneous sparing of critical structures. Our results can add to the ongoing discussion in the design of future 3D-CRT/IMRT protocols

  9. Methodology to reduce 6D patient positional shifts into a 3D linear shift and its verification in frameless stereotactic radiotherapy

    Science.gov (United States)

    Sarkar, Biplab; Ray, Jyotirmoy; Ganesh, Tharmarnadar; Manikandan, Arjunan; Munshi, Anusheel; Rathinamuthu, Sasikumar; Kaur, Harpreet; Anbazhagan, Satheeshkumar; Giri, Upendra K.; Roy, Soumya; Jassal, Kanan; Kalyan Mohanti, Bidhu

    2018-04-01

    The aim of this article is to derive and verify a mathematical formulation for the reduction of the six-dimensional (6D) positional inaccuracies of patients (lateral, longitudinal, vertical, pitch, roll and yaw) to three-dimensional (3D) linear shifts. The formulation was mathematically and experimentally tested and verified for 169 stereotactic radiotherapy patients. The mathematical verification involves the comparison of any (one) of the calculated rotational coordinates with the corresponding value from the 6D shifts obtained by cone beam computed tomography (CBCT). The experimental verification involves three sets of measurements using an ArcCHECK phantom, when (i) the phantom was not moved (neutral position: 0MES), (ii) the position of the phantom shifted by 6D shifts obtained from CBCT (6DMES) from neutral position and (iii) the phantom shifted from its neutral position by 3D shifts reduced from 6D shifts (3DMES). Dose volume histogram and statistical comparisons were made between ≤ft and ≤ft . The mathematical verification was performed by a comparison of the calculated and measured yaw (γ°) rotation values, which gave a straight line, Y  =  1X with a goodness of fit as R 2  =  0.9982. The verification, based on measurements, gave a planning target volume receiving 100% of the dose (V100%) as 99.1  ±  1.9%, 96.3  ±  1.8%, 74.3  ±  1.9% and 72.6  ±  2.8% for the calculated treatment planning system values TPSCAL, 0MES, 3DMES and 6DMES, respectively. The statistical significance (p-values: paired sample t-test) of V100% were found to be 0.03 for the paired sample ≤ft and 0.01 for ≤ft . In this paper, a mathematical method to reduce 6D shifts to 3D shifts is presented. The mathematical method is verified by using well-matched values between the measured and calculated γ°. Measurements done on the ArcCHECK phantom also proved that the proposed methodology is correct. The post-correction of the

  10. 3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision.

    Science.gov (United States)

    Leon, Piera; Rivellini, Roberta; Giudici, Fabiola; Sciuto, Antonio; Pirozzi, Felice; Corcione, Francesco

    2017-04-01

    The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning ( P = .07). 3D vision in laparoscopic HH repair helps surgeon's visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.

  11. Molecular characterization of barley 3H semi-dwarf genes.

    Directory of Open Access Journals (Sweden)

    Haobing Li

    Full Text Available The barley chromosome 3H accommodates many semi-dwarfing genes. To characterize these genes, the two-rowed semi-dwarf Chinese barley landrace 'TX9425' was crossed with the Australian barley variety 'Franklin' to generate a doubled haploid (DH population, and major QTLs controlling plant height have been identified in our previous study. The major QTL derived from 'TX9425' was targeted to investigate the allelism of the semi-dwarf gene uzu in barley. Twelve sets of near-isogenic lines and a large NILF2 fine mapping population segregating only for the dwarfing gene from 'TX9425' were developed. The semi-dwarfing gene in 'TX9425' was located within a 2.8 cM region close to the centromere on chromosome 3H by fine mapping. Molecular cloning and sequence analyses showed that the 'TX9425'-derived allele contained a single nucleotide substitution from A to G at position 2612 of the HvBRI1 gene. This was apparently the same mutation as that reported in six-rowed uzu barley. Markers co-segregating with the QTL were developed from the sequence of the HvBRI1 gene and were validated in the 'TX9425'/'Franklin' DH population. The other major dwarfing QTL derived from the Franklin variety was distally located on chromosome 3HL and co-segregated with the sdw1 diagnostic marker hv20ox2. A third dwarfing gene, expressed only in winter-sown trials, was identified and located on chromosome 3HS. The effects and interactions of these dwarfing genes under different growing conditions are discussed. These results improve our understanding of the genetic mechanisms controlling semi-dwarf stature in barley and provide diagnostic markers for the selection of semi-dwarfness in barley breeding programs.

  12. Formulation, stability and application of a semi-coupled 3-D four-field algorithm

    International Nuclear Information System (INIS)

    Kunz, R.F.; Siebert, B.W.; Cope, W.K.; Foster, N.F.; Antal, S.P.; Ettorre, S.M.

    1996-06-01

    A new 3-D four-field algorithm has been developed to predict general two-phase flows. Ensemble averaged transport equations of mass, momentum, energy and turbulence transport are solved for each field (continuous liquid, continuous vapor, disperse liquid, disperse vapor). This four-field structure allows for analysis of adiabatic and boiling systems which contain flow regimes from bubbly through annular. Interfacial mass, momentum, turbulence and heat transfer models provide coupling between phases. A new semi-coupled implicit method is utilized to solve the set of 25 equations which arise in the formulation. In this paper, three important component numerical strategies employed in the method are summarized. These include: (1) incorporation of interfacial momentum force terms in the control volume face flux reconstruction, (2) phase coupling at the linear solver level, and in the pressure-velocity coupling itself and (3) a multi-step Jacobi block correction scheme for efficient solution of the pressure-Poisson equation. The necessity/effectiveness of these strategies is demonstrated in applications to realistic engineering flows. Though some heated flow test cases are considered, the particular numerics discussed here are germane to adiabatic flows with and without mass transfer

  13. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    DEFF Research Database (Denmark)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel

    2018-01-01

    ) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. RESULTS: 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D...... echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different...... between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r

  14. Development of a definition for Rapid Progression (RP) of renal function in HIV-positive persons : the D:A:D study

    NARCIS (Netherlands)

    Kamara, David A; Ryom, Lene; Ross, Michael; Kirk, Ole; Reiss, Peter; Morlat, Philippe; Moranne, Olivier; Fux, Christoph A; Mocroft, Amanda; Sabin, Caroline; Lundgren, Jens D; Smith, Colette J; Schölvinck, Elisabeth H.

    2014-01-01

    BACKGROUND: No consensus exists on how to define abnormally rapid deterioration in renal function (Rapid Progression, RP). We developed an operational definition of RP in HIV-positive persons with baseline estimated glomerular filtration rate (eGFR) >90 ml/min/1.73 m2 (using Cockcroft Gault) in the

  15. Development of a definition for Rapid Progression (RP) of renal function in HIV-positive persons: the D:A:D study

    NARCIS (Netherlands)

    Kamara, David A.; Ryom, Lene; Ross, Michael; Kirk, Ole; Reiss, Peter; Morlat, Philippe; Moranne, Olivier; Fux, Christoph A.; Mocroft, Amanda; Sabin, Caroline; Lundgren, Jens D.; Smith, Colette J.; Powderly, B.; Shortman, N.; Moecklinghoff, C.; Reilly, G.; Franquet, X.; Ryom, L.; Sabin, C. A.; Kamara, D.; Smith, C.; Phillips, A.; Mocroft, A.; Tverland, J.; Mansfeld, M.; Nielsen, J.; Raben, D.; Lundgren, J. D.; Brandt, R. Salbøl; Rickenbach, M.; Fanti, I.; Krum, E.; Hillebregt, M.; Geffard, S.; Sundström, A.; Prins, J. M.; Kuijpers, T. W.; Scherpbier, H. J.; van der Meer, J. T. M.; Wit, F. W. M. N.; Godfried, M. H.; Nellen, F. J. B.; Lange, J. M. A.; Geerlings, S. E.; van Vugt, M.; Pajkrt, D.; Grijsen, M. L.; Wiersinga, W. J.; Goorhuis, A.; Hovius, J. W. R.

    2014-01-01

    No consensus exists on how to define abnormally rapid deterioration in renal function (Rapid Progression, RP). We developed an operational definition of RP in HIV-positive persons with baseline estimated glomerular filtration rate (eGFR) >90 ml/min/1.73 m2 (using Cockcroft Gault) in the Data

  16. Development of a definition for Rapid Progression (RP) of renal function in HIV-positive persons: the D:A:D study

    NARCIS (Netherlands)

    Kamara, D.A.; Ryom, L.; Ross, M.; Kirk, O.; Reiss, P.; Morlat, P.; Moranne, O.; Fux, C.A.; Mocroft, A.; Sabin, C.; Lundgren, J.D.; Smith, C.J.; Koopmans †, P.P.; Keuter, M.; Ven, A.J.A.M. van der; Hofstede, H.J.M. ter; Dofferhoff, A.S.M.; Warris, A.; Crevel, R. van; et al.,

    2014-01-01

    BACKGROUND: No consensus exists on how to define abnormally rapid deterioration in renal function (Rapid Progression, RP). We developed an operational definition of RP in HIV-positive persons with baseline estimated glomerular filtration rate (eGFR) >90 ml/min/1.73 m2 (using Cockcroft Gault) in the

  17. The Feasibility of 3d Point Cloud Generation from Smartphones

    Science.gov (United States)

    Alsubaie, N.; El-Sheimy, N.

    2016-06-01

    This paper proposes a new technique for increasing the accuracy of direct geo-referenced image-based 3D point cloud generated from low-cost sensors in smartphones. The smartphone's motion sensors are used to directly acquire the Exterior Orientation Parameters (EOPs) of the captured images. These EOPs, along with the Interior Orientation Parameters (IOPs) of the camera/ phone, are used to reconstruct the image-based 3D point cloud. However, because smartphone motion sensors suffer from poor GPS accuracy, accumulated drift and high signal noise, inaccurate 3D mapping solutions often result. Therefore, horizontal and vertical linear features, visible in each image, are extracted and used as constraints in the bundle adjustment procedure. These constraints correct the relative position and orientation of the 3D mapping solution. Once the enhanced EOPs are estimated, the semi-global matching algorithm (SGM) is used to generate the image-based dense 3D point cloud. Statistical analysis and assessment are implemented herein, in order to demonstrate the feasibility of 3D point cloud generation from the consumer-grade sensors in smartphones.

  18. time of arrival 3-d position estimation using minimum ads-b receiver ...

    African Journals Online (AJOL)

    HOD

    The location from which a signal is transmitted can be estimated using the time it takes to be detected at a receiver. The difference between transmission time and the detection time is known as time of arrival (TOA). In this work, an algorithm for 3-dimensional (3-D) position estimation (PE) of an emitter using the minimum ...

  19. 3-D Discrete Analytical Ridgelet Transform

    OpenAIRE

    Helbert , David; Carré , Philippe; Andrès , Éric

    2006-01-01

    International audience; In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines:...

  20. Estimation of the 3D positioning of anatomic structures from radiographic projection and volume knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Bifulco, P; Cesarelli, M; Roccasalva Firenze, M; Verso, E; Sansone, M; Bracale, M [University of Naples, Federico II, Electronic Engineering Department, Bioengineering Unit, Via Claudio, 21 - 80125 Naples (Italy)

    1999-12-31

    The aim of this study is to develop a method to estimate the 3D positioning of an anatomic structure using the knowledge of its volume (provided by CT or MRI) combined with a single radiographic projection. This method could be applied in stereotactic surgery or in the study of 3D body joints kinematics. The knowledge of the 3D anatomical structure, available from CT (or in future MRI) is used to estimate the orientation of the projection that better match the actual 2D available projection. For this purpose it was necessary to develop an algorithm to simulate the radiographic projections. The radiographic image formation process has been simulated utilizing the geometrical characteristics of a real radiographic device and the volumetric anatomical data of the patient, obtained by 3D diagnostic CT images. The position of the patient volume respect to the radiological device is estimated comparing the actual radiographic projection with those simulated, maximising a similarity index. To assess the estimation, the 3D positioning of a segmented vertebra has been used as a test volume. The assessment has been carried out only by means of simulation. Estimation errors have been statistically evaluated. Conditions of mispositioning and noise have been also considered. The results relative to the simulation show the feasibility of the method. From the analysis of the errors emerges that the searching procedure results robust respect to the addition of white Gaussian noise. (authors) 13 fers., 4 figs., 1 tabs.

  1. Estimation of the 3D positioning of anatomic structures from radiographic projection and volume knowledge

    International Nuclear Information System (INIS)

    Bifulco, P.; Cesarelli, M.; Roccasalva Firenze, M.; Verso, E.; Sansone, M.; Bracale, M.

    1998-01-01

    The aim of this study is to develop a method to estimate the 3D positioning of an anatomic structure using the knowledge of its volume (provided by CT or MRI) combined with a single radiographic projection. This method could be applied in stereotactic surgery or in the study of 3D body joints kinematics. The knowledge of the 3D anatomical structure, available from CT (or in future MRI) is used to estimate the orientation of the projection that better match the actual 2D available projection. For this purpose it was necessary to develop an algorithm to simulate the radiographic projections. The radiographic image formation process has been simulated utilizing the geometrical characteristics of a real radiographic device and the volumetric anatomical data of the patient, obtained by 3D diagnostic CT images. The position of the patient volume respect to the radiological device is estimated comparing the actual radiographic projection with those simulated, maximising a similarity index. To assess the estimation, the 3D positioning of a segmented vertebra has been used as a test volume. The assessment has been carried out only by means of simulation. Estimation errors have been statistically evaluated. Conditions of mispositioning and noise have been also considered. The results relative to the simulation show the feasibility of the method. From the analysis of the errors emerges that the searching procedure results robust respect to the addition of white Gaussian noise. (authors)

  2. Initial experience with 3T 3D-TOF MRA in the diagnosis of intracranial aneurysms

    International Nuclear Information System (INIS)

    Senba, Yoshiki; Takahashi, Shizue; Matsubara, Ichiro; Sadamoto, Kazuhiko; Miki, Hitoshi; Mochizuki, Teruhito

    2006-01-01

    We assessed the value of 3T 3D-time of flight (TOF) MR angiography (MRA) in the diagnosis of intracranial aneurysms compared with 1.5T 3D-TOF MRA. Twenty-one patients with 22 aneurysms underwent MRA at 1.5T and 3T. Images were interpreted by two radiologists. Each of nine aneurysms that had been considered ''definite'' at 1.5T 3D-TOF MRA were considered ''definite'' at 3T 3D-TOF MRA. Seven aneurysms that had been considered ''suspicious'' at 1.5T MRA were considered ''definite'' at 3T. And four aneurysms that had been considered ''suspicious'' at 1.5T were considered ''negative'' at 3T. We concluded that 3T 3D-TOF MRA is superior to 1.5T 3D-TOF MRA in the diagnosis of intracranial aneurysms. (author)

  3. Expedient Gap Definition Using 3D LADAR

    National Research Council Canada - National Science Library

    Edwards, Lulu; Jersey, Sarah R

    2006-01-01

    .... Army Engineer Research and Development Center (ERDC), ASI has developed an algorithm to reduce the 3D point cloud acquired with the LADAR system into sets of 2D profiles that describe the terrain...

  4. 21 CFR 146.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... CONSUMPTION CANNED FRUIT JUICES General Provisions § 146.3 Definitions. For the purposes of this part: (a) The... hydrolyzed starch. (c) The term dried glucose sirup means the product obtained by drying glucose sirup. (d... following: Unless otherwise provided in a standard, a lot of canned fruits shall be deemed in compliance for...

  5. Tensor Dictionary Learning for Positive Definite Matrices.

    Science.gov (United States)

    Sivalingam, Ravishankar; Boley, Daniel; Morellas, Vassilios; Papanikolopoulos, Nikolaos

    2015-11-01

    Sparse models have proven to be extremely successful in image processing and computer vision. However, a majority of the effort has been focused on sparse representation of vectors and low-rank models for general matrices. The success of sparse modeling, along with popularity of region covariances, has inspired the development of sparse coding approaches for these positive definite descriptors. While in earlier work, the dictionary was formed from all, or a random subset of, the training signals, it is clearly advantageous to learn a concise dictionary from the entire training set. In this paper, we propose a novel approach for dictionary learning over positive definite matrices. The dictionary is learned by alternating minimization between sparse coding and dictionary update stages, and different atom update methods are described. A discriminative version of the dictionary learning approach is also proposed, which simultaneously learns dictionaries for different classes in classification or clustering. Experimental results demonstrate the advantage of learning dictionaries from data both from reconstruction and classification viewpoints. Finally, a software library is presented comprising C++ binaries for all the positive definite sparse coding and dictionary learning approaches presented here.

  6. Approximation of a solution for a K-positive definite operator equation

    International Nuclear Information System (INIS)

    Chidume, C.E.; Osilike, M.O.

    1994-11-01

    Let E be a separable q-uniformly smooth Banach space, q > 1, and let A : D(A) is contained in-bar E → E be a K-positive definite operator. Let f is an element of E be arbitrary. An iterative method is constructed which converges strongly to the unique solution of the equation Ax = f. Our result resolves two questions raised in Chidume and Aneke (Applicable Analysis Vol. 50 (1993), p. 293). (author). 13 refs

  7. FIJI Macro 3D ART VeSElecT: 3D Automated Reconstruction Tool for Vesicle Structures of Electron Tomograms.

    Directory of Open Access Journals (Sweden)

    Kristin Verena Kaltdorf

    2017-01-01

    Full Text Available Automatic image reconstruction is critical to cope with steadily increasing data from advanced microscopy. We describe here the Fiji macro 3D ART VeSElecT which we developed to study synaptic vesicles in electron tomograms. We apply this tool to quantify vesicle properties (i in embryonic Danio rerio 4 and 8 days past fertilization (dpf and (ii to compare Caenorhabditis elegans N2 neuromuscular junctions (NMJ wild-type and its septin mutant (unc-59(e261. We demonstrate development-specific and mutant-specific changes in synaptic vesicle pools in both models. We confirm the functionality of our macro by applying our 3D ART VeSElecT on zebrafish NMJ showing smaller vesicles in 8 dpf embryos then 4 dpf, which was validated by manual reconstruction of the vesicle pool. Furthermore, we analyze the impact of C. elegans septin mutant unc-59(e261 on vesicle pool formation and vesicle size. Automated vesicle registration and characterization was implemented in Fiji as two macros (registration and measurement. This flexible arrangement allows in particular reducing false positives by an optional manual revision step. Preprocessing and contrast enhancement work on image-stacks of 1nm/pixel in x and y direction. Semi-automated cell selection was integrated. 3D ART VeSElecT removes interfering components, detects vesicles by 3D segmentation and calculates vesicle volume and diameter (spherical approximation, inner/outer diameter. Results are collected in color using the RoiManager plugin including the possibility of manual removal of non-matching confounder vesicles. Detailed evaluation considered performance (detected vesicles and specificity (true vesicles as well as precision and recall. We furthermore show gain in segmentation and morphological filtering compared to learning based methods and a large time gain compared to manual segmentation. 3D ART VeSElecT shows small error rates and its speed gain can be up to 68 times faster in comparison to manual

  8. Using optically scanned 3D data in the restoration of Michelangelo's David

    Science.gov (United States)

    Scopigno, Roberto; Cignoni, Paolo; Callieri, Marco; Ganovelli, Fabio; Impoco, G.; Pingi, P.; Ponchio, F.

    2003-10-01

    Modern 3D scanning technologies allow to reconstruct 3D digital representations of Cultural Heritage artifacts in a semi-automatic way, characterized by very high accuracy and wealth of details. The availability of an accurate digital representation opens several possibilities of utilization to experts (restorers, archivists, museum curators), or to ordinary people (students, museum visitors). 3D scanned data are commonly used for the production of animations, interactive visualizations, or virtual reality applications. A much more exciting opportunity is to use these data in the restoration of Cultural Heritage artworks. The integration between 3D graphic and restoration represents an open research field where many new supporting tools are required; the David restoration project has given several starting points and guidelines to the definition and development of innovative solutions. Digital 3D models can be used in two different but not subsidiary modes: as an instrument for the execution of specific investigations and as a supporting media for the archival and integration of all the restoration-related information, gathered with the different studies and analysis performed on the artwork. In this paper we present some recent work done in the framework of the Michelangelo's David restoration project. A 3D model of the David was reconstructed by the Digital Michelangelo Project, using laser-based 3D scanning technology. We have developed some tools to make those data accessible and useful in the restoration. Preliminary results are reported here together with some directions for further research.

  9. 7 CFR 3.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... (Federal agencies and private sector entities) into their respective databases for the purpose of... 7 Agriculture 1 2010-01-01 2010-01-01 false Definitions. 3.3 Section 3.3 Agriculture Office of the Secretary of Agriculture DEBT MANAGEMENT General § 3.3 Definitions. For the purpose of this part, except as...

  10. A deep 3D residual CNN for false-positive reduction in pulmonary nodule detection.

    Science.gov (United States)

    Jin, Hongsheng; Li, Zongyao; Tong, Ruofeng; Lin, Lanfen

    2018-05-01

    The automatic detection of pulmonary nodules using CT scans improves the efficiency of lung cancer diagnosis, and false-positive reduction plays a significant role in the detection. In this paper, we focus on the false-positive reduction task and propose an effective method for this task. We construct a deep 3D residual CNN (convolution neural network) to reduce false-positive nodules from candidate nodules. The proposed network is much deeper than the traditional 3D CNNs used in medical image processing. Specifically, in the network, we design a spatial pooling and cropping (SPC) layer to extract multilevel contextual information of CT data. Moreover, we employ an online hard sample selection strategy in the training process to make the network better fit hard samples (e.g., nodules with irregular shapes). Our method is evaluated on 888 CT scans from the dataset of the LUNA16 Challenge. The free-response receiver operating characteristic (FROC) curve shows that the proposed method achieves a high detection performance. Our experiments confirm that our method is robust and that the SPC layer helps increase the prediction accuracy. Additionally, the proposed method can easily be extended to other 3D object detection tasks in medical image processing. © 2018 American Association of Physicists in Medicine.

  11. Robust 3D Position Estimation in Wide and Unconstrained Indoor Environments

    Directory of Open Access Journals (Sweden)

    Annette Mossel

    2015-12-01

    Full Text Available In this paper, a system for 3D position estimation in wide, unconstrained indoor environments is presented that employs infrared optical outside-in tracking of rigid-body targets with a stereo camera rig. To overcome limitations of state-of-the-art optical tracking systems, a pipeline for robust target identification and 3D point reconstruction has been investigated that enables camera calibration and tracking in environments with poor illumination, static and moving ambient light sources, occlusions and harsh conditions, such as fog. For evaluation, the system has been successfully applied in three different wide and unconstrained indoor environments, (1 user tracking for virtual and augmented reality applications, (2 handheld target tracking for tunneling and (3 machine guidance for mining. The results of each use case are discussed to embed the presented approach into a larger technological and application context. The experimental results demonstrate the system’s capabilities to track targets up to 100 m. Comparing the proposed approach to prior art in optical tracking in terms of range coverage and accuracy, it significantly extends the available tracking range, while only requiring two cameras and providing a relative 3D point accuracy with sub-centimeter deviation up to 30 m and low-centimeter deviation up to 100 m.

  12. High-Definition 3D Stereoscopic Microscope Display System for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Yoo Kwan-Hee

    2010-01-01

    Full Text Available Biomedical research has been performed by using advanced information techniques, and micro-high-quality stereo images have been used by researchers and/or doctors for various aims in biomedical research and surgery. To visualize the stereo images, many related devices have been developed. However, the devices are difficult to learn for junior doctors and demanding to supervise for experienced surgeons. In this paper, we describe the development of a high-definition (HD three-dimensional (3D stereoscopic imaging display system for operating a microscope or experimenting on animals. The system consists of a stereoscopic camera part, image processing device for stereoscopic video recording, and stereoscopic display. In order to reduce eyestrain and viewer fatigue, we use a preexisting stereo microscope structure and polarized-light stereoscopic display method that does not reduce the quality of the stereo images. The developed system can overcome the discomfort of the eye piece and eyestrain caused by use over a long period of time.

  13. 3D high-definition manometry in evaluation of children after surgery for Hirschsprung's disease: A pilot study.

    Science.gov (United States)

    Banasiuk, Marcin; Banaszkiewicz, Aleksandra; Piotrowski, Dariusz; Albrecht, Piotr; Kamiński, Andrzej; Radzikowski, Andrzej

    2016-03-01

    Anorectal 3-dimensional high definition manometry (3D HRM) could be the best tool for postoperative assessment of restorative surgical procedures for Hirschsprung's disease. The aim of our study was to evaluate patients after surgery for Hirschsprung's disease using 3D HRM. Anorectal function was evaluated using solid state 3D HRM. We measured the length of the anal canal, mean resting squeeze pressures, the presence of rectoanal inhibitory reflex, cough reflex, ano-anal reflex and the bear down manoeuvre. We studied 14 children operated on for Hirschsprung's disease. The mean values of pressure asymmetry were higher in patients after the Duhamel procedure than after the TEPT procedure (29.58% vs. 22.26% during resting and 26.1% vs. 14.01% during squeeze, respectively). No difference between the groups was observed in the measurement of all the manometric parameters except the presence of rectoanal inhibitory reflex (87.5% after TEPT vs. 33% after Duhamel). Anorectal 3D HRM evaluation of patients with Hirschsprung's disease demonstrated that the asymmetry of the anal canal occurred in a similar percentage after both procedures. Copyright © 2015 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  14. Teknologi 3D dalam Proses Pembuatan Komik

    Directory of Open Access Journals (Sweden)

    Johanes Baptista Permadi

    2011-04-01

    Full Text Available Comic has been people’s favorite since 1930. As the growth of years and technology, the demands in designing comic were also increasing. To fulfill the demands, comic authors spent their times to draw so that they have no time to discover other element besides technical. Therefore, it is important if the comic author helped by 3D technology to accelerate technical process so that the comic authors will get extra time to develop other elements like concept and story. Data is gathered from interviews with both semi-professional and professional comic authors who are having problems being solved. Solving problems are conducted by using 3D software to draw picture of distorted space. And then two semi-professional comic authors will try to draw distorted space in tracing the picture from 3D software to see how many times needed to draw hard part traditionally. 

  15. Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

    International Nuclear Information System (INIS)

    Weon, Chijun; Hyun Nam, Woo; Lee, Duhgoon; Ra, Jong Beom; Lee, Jae Young

    2015-01-01

    Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a

  16. 4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours: Comparison with a conventional technique using individual margins

    International Nuclear Information System (INIS)

    Hof, Holger; Rhein, Bernhard; Haering, Peter; Kopp-Schneider, Annette; Debus, Juergen; Herfarth, Klaus

    2009-01-01

    Purpose: To investigate the dosimetric benefit of integration of 4D-CT in the planning target volume (PTV) definition process compared to conventional PTV definition using individual margins in stereotactic body radiotherapy (SBRT) of lung tumours. Material and methods: Two different PTVs were defined: PTV conv consisting of the helical-CT-based clinical target volume (CTV) enlarged isotropically for each spatial direction by the individually measured amount of motion in the 4D-CT, and PTV 4D encompassing the CTVs defined in the 4D-CT phases displaying the extremes of the tumour position. Tumour motion as well as volumetric and dosimetric differences and relations of both PTVs were evaluated. Results: Volumetric examinations revealed a significant reduction of the mean PTV by 4D-CT from 57.7 to 40.7 cm 3 (31%) (p 4D in PTV conv (r = -0.69, 90% confidence limits: -0.87 and -0.34, p = 0.007). Mean lung dose (MLD) was decreased significantly by 17% (p < 0.001). Conclusions: In SBRT of lung tumours the mere use of individual margins for target volume definition cannot compensate for the additional effects that the implementation of 4D-CT phases can offer.

  17. From Point Clouds to Building Information Models: 3D Semi-Automatic Reconstruction of Indoors of Existing Buildings

    Directory of Open Access Journals (Sweden)

    Hélène Macher

    2017-10-01

    Full Text Available The creation of as-built Building Information Models requires the acquisition of the as-is state of existing buildings. Laser scanners are widely used to achieve this goal since they permit to collect information about object geometry in form of point clouds and provide a large amount of accurate data in a very fast way and with a high level of details. Unfortunately, the scan-to-BIM (Building Information Model process remains currently largely a manual process which is time consuming and error-prone. In this paper, a semi-automatic approach is presented for the 3D reconstruction of indoors of existing buildings from point clouds. Several segmentations are performed so that point clouds corresponding to grounds, ceilings and walls are extracted. Based on these point clouds, walls and slabs of buildings are reconstructed and described in the IFC format in order to be integrated into BIM software. The assessment of the approach is proposed thanks to two datasets. The evaluation items are the degree of automation, the transferability of the approach and the geometric quality of results of the 3D reconstruction. Additionally, quality indexes are introduced to inspect the results in order to be able to detect potential errors of reconstruction.

  18. Information Geometry of Positive Measures and Positive-Definite Matrices: Decomposable Dually Flat Structure

    Directory of Open Access Journals (Sweden)

    Shun-ichi Amari

    2014-04-01

    Full Text Available Information geometry studies the dually flat structure of a manifold, highlighted by the generalized Pythagorean theorem. The present paper studies a class of Bregman divergences called the (ρ,τ-divergence. A (ρ,τ -divergence generates a dually flat structure in the manifold of positive measures, as well as in the manifold of positive-definite matrices. The class is composed of decomposable divergences, which are written as a sum of componentwise divergences. Conversely, a decomposable dually flat divergence is shown to be a (ρ,τ -divergence. A (ρ,τ -divergence is determined from two monotone scalar functions, ρ and τ. The class includes the KL-divergence, α-, β- and (α, β-divergences as special cases. The transformation between an affine parameter and its dual is easily calculated in the case of a decomposable divergence. Therefore, such a divergence is useful for obtaining the center for a cluster of points, which will be applied to classification and information retrieval in vision. For the manifold of positive-definite matrices, in addition to the dually flatness and decomposability, we require the invariance under linear transformations, in particular under orthogonal transformations. This opens a way to define a new class of divergences, called the (ρ,τ -structure in the manifold of positive-definite matrices.

  19. Some thoughts on positive definiteness in the consideration of nuclear data covariance matrices

    Energy Technology Data Exchange (ETDEWEB)

    Geraldo, L.P.; Smith, D.L.

    1988-01-01

    Some basic mathematical features of covariance matrices are reviewed, particularly as they relate to the property of positive difiniteness. Physical implications of positive definiteness are also discussed. Consideration is given to an examination of the origins of non-positive definite matrices, to procedures which encourage the generation of positive definite matrices and to the testing of covariance matrices for positive definiteness. Attention is also given to certain problems associated with the construction of covariance matrices using information which is obtained from evaluated data files recorded in the ENDF format. Examples are provided to illustrate key points pertaining to each of the topic areas covered.

  20. Some thoughts on positive definiteness in the consideration of nuclear data covariance matrices

    International Nuclear Information System (INIS)

    Geraldo, L.P.; Smith, D.L.

    1988-01-01

    Some basic mathematical features of covariance matrices are reviewed, particularly as they relate to the property of positive difiniteness. Physical implications of positive definiteness are also discussed. Consideration is given to an examination of the origins of non-positive definite matrices, to procedures which encourage the generation of positive definite matrices and to the testing of covariance matrices for positive definiteness. Attention is also given to certain problems associated with the construction of covariance matrices using information which is obtained from evaluated data files recorded in the ENDF format. Examples are provided to illustrate key points pertaining to each of the topic areas covered

  1. Radiological characterisation by means of 3D-laser modelling and positioning of measurements

    International Nuclear Information System (INIS)

    Hedvall, Robert; Johansson, Patrik; Erixon, Peter; Ekenborg, Fredrik; Quanhong, Feng

    2012-01-01

    AB SVAFO is a nuclear waste technology and decommissioning company based in Sweden in the scenic surroundings of Studsvik on the Baltic coast. SVAFO is owned by the Swedish nuclear power industry. MultiInfo 3D Laser Scan Solution AB is a technical consult company focusing on the development and solution of 3D laser scanning techniques and its applications in different fields. For better viewing we are using a 3D-laser modelling of a building, national coordinates and using radiological measurements from a database. It is then possible to visualize the contamination situation in the whole building using a CAD-program. The results will be used for the upcoming R2-reactor decommissioning and for visualisation of dose rates and contamination levels in other nuclear buildings. For better documentation of radioactivity distribution of a decommissioned facility any object in a building can be accurately measured in 3D and visualized in 3D-laser image in a CAD program (e.g. AutoCAD), and then link to a database (e.g. SVALA), which have stored the measurements of radioactivity by other tools (e.g. RFID-tags). The position of any measured object can also be identified in 3D model and laser image, so the situation of contamination levels and distribution can be monitored and visualized in 3D. The results will be used for visualisation of dose rates and contamination levels in other nuclear buildings. AB SVAFO's main business is to take care of formerly state-owned spent nuclear waste at the site, including small amounts of nuclear fuel. Buildings are also included, mainly nuclear waste storage buildings and a research reactor. Some buildings have already been decommissioned with results of contamination shown in long and not very clear tables. With 3D-modelling the results are shown more clear. (authors)

  2. How to perform 3D reconstruction of skull base tumours.

    Science.gov (United States)

    Bonne, N-X; Dubrulle, F; Risoud, M; Vincent, C

    2017-04-01

    The surgical management of skull base lesions is difficult due to the complex anatomy of the region and the intimate relations between the lesion and adjacent nerves and vessels. Minimally invasive approaches are increasingly used in skull base surgery to ensure an optimal functional prognosis. Three-dimensional (3D) computed tomography (CT) reconstruction facilitates surgical planning by visualizing the anatomical relations of the lesions in all planes (arteries, veins, nerves, inner ear) and simulation of the surgical approach in the operating position. Helical CT angiography is performed with optimal timing of the injection in terms of tumour and vessel contrast enhancement. 3D definition of each structure is based on colour coding by automatic thresholding (bone, vessels) or manual segmentation on each slice (tumour, nerves, inner ear). Imaging is generally presented in 3 dimensions (superior, coronal, sagittal) with simulation of the surgical procedure (5 to 6 reconstructions in the operating position at different depths). Copyright © 2016. Published by Elsevier Masson SAS.

  3. Semi-automated tabulation of the 3D topology and morphology of branching networks using CT: application to the airway tree

    International Nuclear Information System (INIS)

    Sauret, V.; Bailey, A.G.

    1999-01-01

    Detailed information on biological branching networks (optical nerves, airways or blood vessels) is often required to improve the analysis of 3D medical imaging data. A semi-automated algorithm has been developed to obtain the full 3D topology and dimensions (direction cosine, length, diameter, branching and gravity angles) of branching networks using their CT images. It has been tested using CT images of a simple Perspex branching network and applied to the CT images of a human cast of the airway tree. The morphology and topology of the computer derived network were compared with the manually measured dimensions. Good agreement was found. The airways dimensions also compared well with previous values quoted in literature. This algorithm can provide complete data set analysis much more quickly than manual measurements. Its use is limited by the CT resolution which means that very small branches are not visible. New data are presented on the branching angles of the airway tree. (author)

  4. Propagation of positional error in 3D GIS

    NARCIS (Netherlands)

    Biljecki, Filip; Heuvelink, Gerard B.M.; Ledoux, Hugo; Stoter, Jantien

    2015-01-01

    While error propagation in GIS is a topic that has received a lot of attention, it has not been researched with 3D GIS data. We extend error propagation to 3D city models using a Monte Carlo simulation on a use case of annual solar irradiation estimation of building rooftops for assessing the

  5. WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

    International Nuclear Information System (INIS)

    De Silva, T; Ketcha, M; Siewerdsen, J H; Uneri, A; Reaungamornrat, S; Vogt, S; Kleinszig, G; Lo, S F; Wolinsky, J P; Gokaslan, Z L; Aygun, N

    2015-01-01

    Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such

  6. WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, T; Ketcha, M; Siewerdsen, J H [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD (United States); Uneri, A; Reaungamornrat, S [Department of Computer Science, Johns Hopkins University, Baltimore, MD (United States); Vogt, S; Kleinszig, G [Siemens Healthcare XP Division, Erlangen, DE (Germany); Lo, S F; Wolinsky, J P; Gokaslan, Z L [Department of Neurosurgery, The Johns Hopkins Hospital, Baltimore, MD (United States); Aygun, N [Department of Raiology and Radiological Sciences, The Johns Hopkins Hospital, Baltimore, MD (United States)

    2015-06-15

    Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such

  7. 17 CFR 270.12d2-1 - Definition of insurance company for purposes of sections 12(d)(2) and 12(g) of the Act.

    Science.gov (United States)

    2010-04-01

    ..., INVESTMENT COMPANY ACT OF 1940 § 270.12d2-1 Definition of insurance company for purposes of sections 12(d)(2... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Definition of insurance company for purposes of sections 12(d)(2) and 12(g) of the Act. 270.12d2-1 Section 270.12d2-1 Commodity...

  8. A generic semi-implicit coupling methodology for use in RELAP5-3Dcopyright

    International Nuclear Information System (INIS)

    Aumiller, D.L.; Tomlinson, E.T.; Weaver, W.L.

    2000-01-01

    A generic semi-implicit coupling methodology has been developed and implemented in the RELAP5-3Dcopyright computer program. This methodology allows RELAP5-3Dcopyright to be used with other computer programs to perform integrated analyses of nuclear power reactor systems and related experimental facilities. The coupling methodology potentially allows different programs to be used to model different portions of the system. The programs are chosen based on their capability to model the phenomena that are important in the simulation in the various portions of the system being considered. The methodology was demonstrated using a test case in which the test geometry was divided into two parts each of which was solved as a RELAP5-3Dcopyright simulation. This test problem exercised all of the semi-implicit coupling features which were installed in RELAP5-3D0. The results of this verification test case show that the semi-implicit coupling methodology produces the same answer as the simulation of the test system as a single process

  9. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    Science.gov (United States)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. CsI calorimeter with 3-D position resolution

    CERN Document Server

    Schopper, Herwig Franz; Shaw, H; Nefzger, C; Zoglauer, A; Schönfelder, V; Kanbach, G

    2000-01-01

    New gamma-ray calorimeter have been developed for the MEGA Compton camera. They consist of arrays of small CsI(Tl) scintillator bars read out by Silicon PIN-diodes and low noise, self-triggering frontend electronics. The length of the bars (the thickness of the calorimeter) can be varied for different applications to fit the stopping power needed and the light loss tolerable. In this paper we present calibration results from 2 cm long bars with diodes on one side, and 8 cm long bars with diodes on two opposite sides. Double-sided readout gives 3-D information of interactions which will be used to overcome the limited position resolution in Anger-cameras at high energies. Simpler detection devices like Anger-cameras might finally resolve only the centre of gravity. As events from gamma-rays with energies of MeV do extend over several cm, it is a prerequisite for an imaging device to resolve the interaction structure in detail. Combining CsI(Tl) scintillators, Silicon PIN-photodiodes and frontend electronics in...

  11. The face in marfan syndrome: A 3D quantitative approach for a better definition of dysmorphic features.

    Science.gov (United States)

    Dolci, Claudia; Pucciarelli, Valentina; Gibelli, Daniele M; Codari, Marina; Marelli, Susan; Trifirò, Giuliana; Pini, Alessandro; Sforza, Chiarella

    2018-04-01

    Marfan syndrome (MFS) is a rare hereditable disorder of connective tissue caused by mutations in the fibrillin-1 gene FBN1. Timely diagnosis of MFS is essential to prevent life-threatening cardiovascular complications; nevertheless it can be difficult owing to the phenotypic variability of the syndrome. No clear quantitative definition of facial abnormalities associated with MFS is available. The aim of this study was to improve the definition of the facial phenotype associated with MFS and to verify the usefulness of a 3D noninvasive quantitative approach for its early recognition. 3D facial images of 61 Italian subjects with MFS, aged 16-64 years (21 males, 38 ± 15 years; 40 females, 41 ± 13 years) were obtained by stereophotogrammetry. From the coordinates of 17 soft-tissue facial landmarks, linear distances and angles were computed; z score values were calculated to compare patients with healthy reference subjects (400 males, 379 females) matched for sex and age. Student's t test was used for statistical comparisons. All subjects with MFS showed greater facial divergence (P sex differences. Quantitative abnormalities identified in this study enrich information about the facial dysmorphism in MFS and confirm its usefulness for early recognition of the disease. Clin. Anat. 31:380-386, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. Computationally efficient storage of 3D particle intensity and position data for use in 3D PIV and 3D PTV

    International Nuclear Information System (INIS)

    Atkinson, C; Buchmann, N A; Soria, J

    2013-01-01

    Three-dimensional (3D) volumetric velocity measurement techniques, such as tomographic or holographic particle image velocimetry (PIV), rely upon the computationally intensive formation, storage and localized interrogation of multiple 3D particle intensity fields. Calculation of a single velocity field typically requires the extraction of particle intensities into tens of thousands of 3D sub-volumes or discrete particle clusters, the processing of which can significantly affect the performance of 3D cross-correlation based PIV and 3D particle tracking velocimetry (PTV). In this paper, a series of popular and customized volumetric data formats are presented and investigated using synthetic particle volumes and experimental data arising from tomographic PIV measurements of a turbulent boundary layer. Results show that the use of a sub-grid ordered non-zero intensity format with a sub-grid size of 16 × 16 × 16 points provides the best performance for cross-correlation based PIV analysis, while a particle clustered non-zero intensity format provides the best format for PTV applications. In practical tomographic PIV measurements the sub-grid ordered non-zero intensity format offered a 29% improvement in reconstruction times, while providing a 93% reduction in volume data requirements and a 28% overall improvement in cross-correlation based velocity analysis and validation times. (paper)

  13. COMPARING OF THE 2D-3D GRAVITY CALCULATIONS IN CARTESIAN COORDINATES AND 3D IN CARTESIAN-SPHERICAL COORDINATES

    OpenAIRE

    Çavşak, Hasan; Elmas, Ali

    2014-01-01

    In this study, various calculations comparisons are made to achieve the best results in gravity computation. In the three dimensional (3D) gravity study, mass surfaces are defined by dividing the triangle surfaces. The more triangle surface is taken, the more precise definition of mass are made. Triangular pyramids are taken into consideration as the 3D master model. This model is formed between each triangle surface and calculation point. This method can describe complex shaped formation per...

  14. Related factors to semi-recumbent position compliance and pressure ulcers in patients with invasive mechanical ventilation: An observational study (CAPCRI study).

    Science.gov (United States)

    Llaurado-Serra, Mireia; Ulldemolins, Marta; Fernandez-Ballart, Joan; Guell-Baro, Rosa; Valentí-Trulls, Teresa; Calpe-Damians, Neus; Piñol-Tena, Angels; Pi-Guerrero, Mercedes; Paños-Espinosa, Cristina; Sandiumenge, Alberto; Jimenez-Herrera, María F

    2016-09-01

    Semi-recumbent position is recommended to prevent ventilator-associated pneumonia. Its implementation, however, is below optimal. We aimed to assess real semi-recumbent position compliance and the degree of head-of-bed elevation in Spanish intensive care units, along with factors determining compliance and head-of-bed elevation and their relationship with the development of pressure ulcers. Finally, we investigated the impact that might have the diagnosis of pressure ulcers in the attitude toward head-of-bed elevation. We performed a prospective, multicenter, observational study in 6 intensive care units. Inclusion criteria were patients ≥18 years old and expected to remain under mechanical ventilator for ≥48h. Exclusion criteria were patients with contraindications for semi-recumbent position from admission, mechanical ventilation during the previous 7 days and prehospital intubation. Head-of-bed elevation was measured 3 times/day for a maximum of 28 days using the BOSCH GLM80(®) device. The variables collected related to patient admission, risk of pressure ulcers and the measurements themselves. Bivariate and multivariate analyses were carried out using multiple binary logistic regression and linear regression as appropriate. Statistical significance was set at preplacement therapy, nursing shift, open abdomen, abdominal vacuum therapy and agitation. Twenty-five patients (9.1%) developed a total of 34 pressure ulcers. The diagnosis of pressure ulcers did not affect the head-of-bed elevation. In the multivariate analysis, head-of-bed elevation was not identified as an independent risk factor for pressure ulcers. Semi-recumbent position compliance is below optimal despite the fact that it seems achievable most of the time. Factors that affect semi-recumbent position include the particular intensive care unit, abdominal conditions, renal replacement therapy, agitation and bed type. Head-of-bed elevation was not related to the risk of pressure ulcers. Efforts

  15. 16 CFR 1404.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Definitions. 1404.3 Section 1404.3... INSULATION § 1404.3 Definitions. The definitions in section 3 of the Consumer Product Safety Act (15 U.S.C... as the marketer of the brand). ...

  16. Position sensitive X-ray or X-ray detector and 3-D-tomography using same

    International Nuclear Information System (INIS)

    1975-01-01

    A fan-shaped beam of penetrating radiation, such as X-ray or γ-ray radiation, is directed through a slice of the body to be analyzed into a position sensitive detector for deriving a shadowgraph of transmission or absorption of the penetrating radiation by the body. A number of such shadowgraphs are obtained for different angles of rotation of the fan-shaped beam relative to the center of the slice being analyzed. The detected fan beam shadowgraph data is reordered into shadowgraph data corresponding to sets of parallel paths of radiation through the body. The reordered parallel path shadowgraph data is then convoluted in accordance with a 3-D reconstruction method by convolution in a computer to derive a 3-D reconstructed tomograph of the body under analysis. In a preferred embodiment, the position sensitive detector comprises a multiwire detector wherein the wires are arrayed parallel to the direction of the divergent penetrating rays to be detected. A focussed grid collimator is interposed between the body and the position sensitive detector for collimating the penetrating rays to be detected. The source of penetrating radiation is preferably a monochromatic source

  17. A hierarchical 3D segmentation method and the definition of vertebral body coordinate systems for QCT of the lumbar spine.

    Science.gov (United States)

    Mastmeyer, André; Engelke, Klaus; Fuchs, Christina; Kalender, Willi A

    2006-08-01

    We have developed a new hierarchical 3D technique to segment the vertebral bodies in order to measure bone mineral density (BMD) with high trueness and precision in volumetric CT datasets. The hierarchical approach starts with a coarse separation of the individual vertebrae, applies a variety of techniques to segment the vertebral bodies with increasing detail and ends with the definition of an anatomic coordinate system for each vertebral body, relative to which up to 41 trabecular and cortical volumes of interest are positioned. In a pre-segmentation step constraints consisting of Boolean combinations of simple geometric shapes are determined that enclose each individual vertebral body. Bound by these constraints viscous deformable models are used to segment the main shape of the vertebral bodies. Volume growing and morphological operations then capture the fine details of the bone-soft tissue interface. In the volumes of interest bone mineral density and content are determined. In addition, in the segmented vertebral bodies geometric parameters such as volume or the length of the main axes of inertia can be measured. Intra- and inter-operator precision errors of the segmentation procedure were analyzed using existing clinical patient datasets. Results for segmented volume, BMD, and coordinate system position were below 2.0%, 0.6%, and 0.7%, respectively. Trueness was analyzed using phantom scans. The bias of the segmented volume was below 4%; for BMD it was below 1.5%. The long-term goal of this work is improved fracture prediction and patient monitoring in the field of osteoporosis. A true 3D segmentation also enables an accurate measurement of geometrical parameters that may augment the clinical value of a pure BMD analysis.

  18. General beam position controlling method for 3D optical systems based on the method of solving ray matrix equations

    Science.gov (United States)

    Chen, Meixiong; Yuan, Jie; Long, Xingwu; Kang, Zhenglong; Wang, Zhiguo; Li, Yingying

    2013-12-01

    A general beam position controlling method for 3D optical systems based on the method of solving ray matrix equations has been proposed in this paper. As a typical 3D optical system, nonplanar ring resonator of Zero-Lock Laser Gyroscopes has been chosen as an example to show its application. The total mismatching error induced by Faraday-wedge in nonplanar ring resonator has been defined and eliminated quite accurately with the error less than 1 μm. Compared with the method proposed in Ref. [14], the precision of the beam position controlling has been improved by two orders of magnitude. The novel method can be used to implement automatic beam position controlling in 3D optical systems with servo circuit. All those results have been confirmed by related alignment experiments. The results in this paper are important for beam controlling, ray tracing, cavity design and alignment in 3D optical systems.

  19. Reproducibility of the interpretation of coronal 3D ultrasound view of the uterus to evaluate the position of Essure® 3 months after hysteroscopic procedure.

    Science.gov (United States)

    Capmas, P; Letendre, I; Levaillant, J-M; Fuchs, F; Panel, P; Chambon, G; Villefranque, V; Levy-Zauberman, Y; Fernandez, H

    2017-09-01

    Three-dimensional sonography is a good alternative method to assess the position of microinserts. Adequate position after three months allows for the interruption of other contraception. Objective is to evaluate inter-observer reproducibility of the interpretation of coronal transvaginal 3D ultrasound view of the uterus to evaluate the position of Essure ® . Inter-observer reproducibility study. Fifty women underwent successful bilateral placement of microinserts (Essure ® ) by hysteroscopy in the Department of Gynaecology of a teaching hospital and were included in the study. At three month, 3D ultrasound coronal views of the fifty uterus (accounting for one hundred microinserts) were assessed by five different observers and microinsert position was classified according to the classification described by Legendre et al. Inter-observer reproducibility in reading the 3D coronal view of the uterus was evaluated. The k-value was disparate, from 0.26 to 0.82. Inter-observer reproducibility then ranged from fair to almost perfect, depending on a prior knowledge of the position classification. Transvaginal 3D coronal view of the uterus is sufficient to assess the positioning of the microinserts when the practionner or the surgeon is familiar with the classification method. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Fabrication and characterization of a 3D Positive ion detector and its applications

    Science.gov (United States)

    Venkatraman, Pitchaikannu; Sureka, Chandrasekaran Senbagavadivoo

    2017-11-01

    There is a growing interest to experimentally evaluate the track structure induced by ionizing particles in order to characterize the radiobiological quality of ionizing radiation for applications in radiotherapy and radiation protection. To do so, a novel positive ion detector based on the multilayer printed circuit board (PCB) technology has been proposed previously, which works under the principle of ion induced impact ionization. Based on this, an upgraded 3D positive ion detector was fabricated in order to improve its efficiency and use it for various applications. To improve the efficiency of the detector, cathodes with different insulators (Bakelite plate and Steatite Ceramics) and conducting layers (ITO, FTO, and Gold coated cathode) were studied under various gaseous media (methane, nitrogen, and air) using Am-241, Co-60, Co-57, Na-22, Cs-137, and Ba-133 sources. From this study, it is confirmed that the novel 3D positive ion detector that has been upgraded using gold as strip material, tungsten (87%) coated copper (13%) as the core wire, gold coated ceramic as cathode, and thickness of 3.483 mm showed 9.2% efficiency under methane medium at 0.9 Torr pressure using an Am-241 source. It is also confirmed that when the conductivity of the cathode and thickness of the detector is increased, the performance of the detector is improved significantly. Further, the scope of the detector to use in the field of radiation protection, radiation dosimetry, gamma spectrometry, radiation biology, and oncology are reported here.

  1. Eigenvalues of Words in Two Positive Definite Letters

    OpenAIRE

    Hillar, Christopher J; Johnson, Charles R

    2005-01-01

    The question of whether all words in two real positive definite letters have only positive eigenvalues is addressed and settled (negatively). This question was raised some time ago in connection with a long-standing problem in theoretical physics. A large class of words that do guarantee positive eigenvalues is identified, and considerable evidence is given for the conjecture that no other words do. In the process, a fundamental question about solvability of symmetric word equations is encoun...

  2. 3D position estimation using an artificial neural network for a continuous scintillator PET detector

    International Nuclear Information System (INIS)

    Wang, Y; Zhu, W; Cheng, X; Li, D

    2013-01-01

    Continuous crystal based PET detectors have features of simple design, low cost, good energy resolution and high detection efficiency. Through single-end readout of scintillation light, direct three-dimensional (3D) position estimation could be another advantage that the continuous crystal detector would have. In this paper, we propose to use artificial neural networks to simultaneously estimate the plane coordinate and DOI coordinate of incident γ photons with detected scintillation light. Using our experimental setup with an ‘8 + 8’ simplified signal readout scheme, the training data of perpendicular irradiation on the front surface and one side surface are obtained, and the plane (x, y) networks and DOI networks are trained and evaluated. The test results show that the artificial neural network for DOI estimation is as effective as for plane estimation. The performance of both estimators is presented by resolution and bias. Without bias correction, the resolution of the plane estimator is on average better than 2 mm and that of the DOI estimator is about 2 mm over the whole area of the detector. With bias correction, the resolution at the edge area for plane estimation or at the end of the block away from the readout PMT for DOI estimation becomes worse, as we expect. The comprehensive performance of the 3D positioning by a neural network is accessed by the experimental test data of oblique irradiations. To show the combined effect of the 3D positioning over the whole area of the detector, the 2D flood images of oblique irradiation are presented with and without bias correction. (paper)

  3. Experimental validation of improved 3D SBP positioning algorithm in PET applications using UW Phase II Board

    Energy Technology Data Exchange (ETDEWEB)

    Jorge, L.S.; Bonifacio, D.A.B. [Institute of Radioprotection and Dosimetry, IRD/CNEN (Brazil); DeWitt, Don; Miyaoka, R.S. [Imaging Research Laboratory, IRL/UW (United States)

    2016-12-01

    Continuous scintillator-based detectors have been considered as a competitive and cheaper approach than highly pixelated discrete crystal positron emission tomography (PET) detectors, despite the need for algorithms to estimate 3D gamma interaction position. In this work, we report on the implementation of a positioning algorithm to estimate the 3D interaction position in a continuous crystal PET detector using a Field Programmable Gate Array (FPGA). The evaluated method is the Statistics-Based Processing (SBP) technique that requires light response function and event position characterization. An algorithm has been implemented using the Verilog language and evaluated using a data acquisition board that contains an Altera Stratix III FPGA. The 3D SBP algorithm was previously successfully implemented on a Stratix II FPGA using simulated data and a different module design. In this work, improvements were made to the FPGA coding of the 3D positioning algorithm, reducing the total memory usage to around 34%. Further the algorithm was evaluated using experimental data from a continuous miniature crystal element (cMiCE) detector module. Using our new implementation, average FWHM (Full Width at Half Maximum) for the whole block is 1.71±0.01 mm, 1.70±0.01 mm and 1.632±0.005 mm for x, y and z directions, respectively. Using a pipelined architecture, the FPGA is able to process 245,000 events per second for interactions inside of the central area of the detector that represents 64% of the total block area. The weighted average of the event rate by regional area (corner, border and central regions) is about 198,000 events per second. This event rate is greater than the maximum expected coincidence rate for any given detector module in future PET systems using the cMiCE detector design.

  4. 3D Surgical Simulation

    OpenAIRE

    Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2010-01-01

    This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive ...

  5. CsI calorimeter with 3-D position resolution

    International Nuclear Information System (INIS)

    Schopper, F.; Andritschke, R.; Shaw, H.; Nefzger, C.; Zoglauer, A.; Schoenfelder, V.; Kanbach, G.

    2000-01-01

    New γ-ray calorimeter have been developed for the MEGA Compton camera. They consist of arrays of small CsI(Tl) scintillator bars read out by Silicon PIN-diodes and low noise, self-triggering frontend electronics. The length of the bars (the thickness of the calorimeter) can be varied for different applications to fit the stopping power needed and the light loss tolerable. In this paper we present calibration results from 2 cm long bars with diodes on one side, and 8 cm long bars with diodes on two opposite sides. Double-sided readout gives 3-D information of interactions which will be used to overcome the limited position resolution in Anger-cameras at high energies. Simpler detection devices like Anger-cameras might finally resolve only the centre of gravity. As events from γ-rays with energies of MeV do extend over several cm, it is a prerequisite for an imaging device to resolve the interaction structure in detail. Combining CsI(Tl) scintillators, Silicon PIN-photodiodes and frontend electronics inside the housing results in a cheap rugged design. While the development in our institute is mainly done for the Compton camera prototype, many other applications are conceivable

  6. A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging

    Science.gov (United States)

    Yang, Yunjie; Jia, Jiabin

    2017-08-01

    This paper presents the design and evaluation of a configurable, fast multi-frequency Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging, particularly for biomedical imaging. The system integrates 32 electrode interfaces and the current frequency ranges from 10 kHz to 1 MHz. The system incorporates the following novel features. First, a fully adjustable multi-frequency current source with current monitoring function is designed. Second, a flexible switching scheme is developed for arbitrary sensing configuration and a semi-parallel data acquisition architecture is implemented for high-frame-rate data acquisition. Furthermore, multi-frequency digital quadrature demodulation is accomplished in a high-capacity Field Programmable Gate Array. At last, a 3D imaging software, visual tomography, is developed for real-time 2D and 3D image reconstruction, data analysis, and visualization. The mfEIT system is systematically tested and evaluated from the aspects of signal to noise ratio (SNR), frame rate, and 2D and 3D multi-frequency phantom imaging. The highest SNR is 82.82 dB on a 16-electrode sensor. The frame rate is up to 546 fps at serial mode and 1014 fps at semi-parallel mode. The evaluation results indicate that the presented mfEIT system is a powerful tool for real-time 2D and 3D imaging.

  7. 26 CFR 1.860D-1 - Definition of a REMIC.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Definition of a REMIC. 1.860D-1 Section 1.860D-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860D-1 Definition of a REMIC. (a) In general. A real...

  8. 50 CFR 21.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Definitions. 21.3 Section 21.3 Wildlife... (CONTINUED) MIGRATORY BIRD PERMITS Introduction § 21.3 Definitions. In addition to definitions contained in... environment that is intensively manipulated by man for the purpose of producing raptors of selected species...

  9. Short-Term and Long-Term Forecasting for the 3D Point Position Changing by Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Eleni-Georgia Alevizakou

    2018-03-01

    Full Text Available Forecasting is one of the most growing areas in most sciences attracting the attention of many researchers for more extensive study. Therefore, the goal of this study is to develop an integrated forecasting methodology based on an Artificial Neural Network (ANN, which is a modern and attractive intelligent technique. The final result is to provide short-term and long-term forecasts for point position changing, i.e., the displacement or deformation of the surface they belong to. The motivation was the combination of two thoughts, the insertion of the forecasting concept in Geodesy as in the most scientific disciplines (e.g., Economics, Medicine and the desire to know the future position of any point on a construction or on the earth’s crustal. This methodology was designed to be accurate, stable and general for different kind of geodetic data. The basic procedure consists of the definition of the forecasting problem, the preliminary data analysis (data pre-processing, the definition of the most suitable ANN, its evaluation using the proper criteria and finally the production of forecasts. The methodology gives particular emphasis on the stages of the pre-processing and the evaluation. Additionally, the importance of the prediction intervals (PI is emphasized. A case study, which includes geodetic data from the year 2003 to the year 2016—namely X, Y, Z coordinates—is implemented. The data were acquired by 1000 permanent Global Navigation Satellite System (GNSS stations. During this case study, 2016 ANNs—with different hyper-parameters—are trained and tested for short-term forecasting and 2016 for long-term forecasting, for each of the GNSS stations. In addition, other conventional statistical forecasting methods are used for the same purpose using the same data set. Finally the most appropriate Non-linear Autoregressive Recurrent network (NAR or Non-linear Autoregressive with eXogenous inputs (NARX for the forecasting of 3D point

  10. Precipitation Processes Developed During ARM (1997), TOGA COARE (1992) GATE (1974), SCSMEX (1998), and KWAJEX (1999): Consistent 3D, Semi-3D and 3D Cloud Resolving Model Simulations

    Science.gov (United States)

    Tao, W.-K.; Hou, A.; Atlas, R.; Starr, D.; Sud, Y.

    2003-01-01

    Real clouds and cloud systems are inherently three-dimensional (3D). Because of the limitations in computer resources, however, most cloud-resolving models (CRMs) today are still two-dimensional (2D) have been used to study the response of clouds to large-scale forcing. IN these 3D simulators, the model domain was small, and the integration time was 6 hours. Only recently have 3D experiments been performed for multi-day periods for tropical clouds systems with large horizontal domains at the National Center of Atmospheric Research (NCAR) and at NASA Goddard Space Center. At Goddard, a 3D cumulus Ensemble (GCE) model was used to simulate periods during TOGA COARE, GATE, SCSMEX, ARM, and KWAJEX using a 512 by 512 km domain (with 2-km resolution). The result indicate that surface precipitation and latent heating profiles are very similar between the 2D and 3D GCE model simulation. The major objective of this paper are: (1) to assess the performance of the super-parametrization technique, (2) calculate and examine the surface energy (especially radiation) and water budget, and (3) identify the differences and similarities in the organization and entrainment rates of convection between simulated 2D and 3D cloud systems.

  11. Inkjet-/3D-/4D-printed autonomous wearable RF modules for biomonitoring, positioning and sensing applications

    Science.gov (United States)

    Bito, Jo; Bahr, Ryan; Hester, Jimmy; Kimionis, John; Nauroze, Abdullah; Su, Wenjing; Tehrani, Bijan; Tentzeris, Manos M.

    2017-05-01

    In this paper, numerous inkjet-/3D-/4D-printed wearable flexible antennas, RF electronics, modules and sensors fabricated on paper and other polymer (e.g. LCP) substrates are introduced as a system-level solution for ultra-low-cost mass production of autonomous Biomonitoring, Positioning and Sensing applications. This paper briefly discusses the state-of-the-art area of fully-integrated wearable wireless sensor modules on paper or flexible LCP and show the first ever 4D sensor module integration on paper, as well as numerous 3D and 4D multilayer paper-based and LCP-based RF/microwave, flexible and wearable structures, that could potentially set the foundation for the truly convergent wireless sensor ad-hoc "on-body networks of the future with enhanced cognitive intelligence and "rugged" packaging. Also, some challenges concerning the power sources of "nearperpetual" wearable RF modules, including flexible miniaturized batteries as well as power-scavenging approaches involving electromagnetic and solar energy forms are discuessed. The final step of the paper will involve examples from mmW wearable (e.g. biomonitoring) antennas and RF modules, as well as the first examples of the integration of inkjet-printed nanotechnology-based (e.g.CNT) sensors on paper and organic substrates for Internet of Things (IoT) applications. It has to be noted that the paper will review and present challenges for inkjetprinted organic active and nonlinear devices as well as future directions in the area of environmentally-friendly "green") wearable RF electronics and "smart-skin conformal sensors.

  12. Localization of liver tumors in freehand 3D laparoscopic ultrasound

    Science.gov (United States)

    Shahin, O.; Martens, V.; Besirevic, A.; Kleemann, M.; Schlaefer, A.

    2012-02-01

    The aim of minimally invasive laparoscopic liver interventions is to completely resect or ablate tumors while minimizing the trauma caused by the operation. However, restrictions such as limited field of view and reduced depth perception can hinder the surgeon's capabilities to precisely localize the tumor. Typically, preoperative data is acquired to find the tumor(s) and plan the surgery. Nevertheless, determining the precise position of the tumor is required, not only before but also during the operation. The standard use of ultrasound in hepatic surgery is to explore the liver and identify tumors. Meanwhile, the surgeon mentally builds a 3D context to localize tumors. This work aims to upgrade the use of ultrasound in laparoscopic liver surgery. We propose an approach to segment and localize tumors intra-operatively in 3D ultrasound. We reconstruct a 3D laparoscopic ultrasound volume containing a tumor. The 3D image is then preprocessed and semi-automatically segmented using a level set algorithm. During the surgery, for each subsequent reconstructed volume, a fast update of the tumor position is accomplished via registration using the previously segmented and localized tumor as a prior knowledge. The approach was tested on a liver phantom with artificial tumors. The tumors were localized in approximately two seconds with a mean error of less than 0.5 mm. The strengths of this technique are that it can be performed intra-operatively, it helps the surgeon to accurately determine the location, shape and volume of the tumor, and it is repeatable throughout the operation.

  13. Using virtual ridge augmentation and 3D printing to fabricate a titanium mesh positioning device: A novel technique letter.

    Science.gov (United States)

    Al-Ardah, Aladdin; Alqahtani, Nasser; AlHelal, Abdulaziz; Goodacre, Brian; Swamidass, Rajesh; Garbacea, Antoanela; Lozada, Jaime

    2018-05-02

    This technique describes a novel approach for planning and augmenting a large bony defect using a titanium mesh (TiMe). A 3-dimensional (3D) surgical model was virtually created from a cone beam computed tomography (CBCT) and wax-pattern of the final prosthetic outcome. The required bone volume (horizontally and vertically) was digitally augmented and then 3D printed to create a bone model. The 3D model was then used to contour the TiMe in accordance with the digital augmentation. With the contoured / preformed TiMe on the 3D printed model a positioning jig was made to aid the placement of the TiMe as planned during surgery. Although this technique does not impact the final outcome of the augmentation procedure, it allows the clinician to virtually design the augmentation, preform and contour the TiMe, and create a positioning jig reducing surgical time and error.

  14. The role of 3-D interactive visualization in blind surveys of H I in galaxies

    Science.gov (United States)

    Punzo, D.; van der Hulst, J. M.; Roerdink, J. B. T. M.; Oosterloo, T. A.; Ramatsoku, M.; Verheijen, M. A. W.

    2015-09-01

    Upcoming H I surveys will deliver large datasets, and automated processing using the full 3-D information (two positional dimensions and one spectral dimension) to find and characterize H I objects is imperative. In this context, visualization is an essential tool for enabling qualitative and quantitative human control on an automated source finding and analysis pipeline. We discuss how Visual Analytics, the combination of automated data processing and human reasoning, creativity and intuition, supported by interactive visualization, enables flexible and fast interaction with the 3-D data, helping the astronomer to deal with the analysis of complex sources. 3-D visualization, coupled to modeling, provides additional capabilities helping the discovery and analysis of subtle structures in the 3-D domain. The requirements for a fully interactive visualization tool are: coupled 1-D/2-D/3-D visualization, quantitative and comparative capabilities, combined with supervised semi-automated analysis. Moreover, the source code must have the following characteristics for enabling collaborative work: open, modular, well documented, and well maintained. We review four state of-the-art, 3-D visualization packages assessing their capabilities and feasibility for use in the case of 3-D astronomical data.

  15. A new imaging 2D and 3D for musculo-skeletal physiology and pathology with low radiation dose and standing position: the EOS system; Une nouvelle imagerie osteo-articulaire basse dose en position debout: le systeme EOS

    Energy Technology Data Exchange (ETDEWEB)

    Dubousset, J. [Academie Nationale de Medecine, et Hopital Saint Vincent de Paul, Service de Chirurgie Orthopedique, 75 - Paris (France); Charpak, G.; Dorion, I. [Biospace, Instruments, 75 - Paris (France); Skalli, W.; Lavaste, F. [Ecole Nationale Superieure des Arts et Metiers, 75 - Paris (France); Deguise, J. [Laboratoire de Recherche en Imagerie Orthopedique, Montreal (Canada); Kalifa, G.; Ferey, S. [Hopital Saint Vincent de Paul, Service de Radiologie, 75 - Paris (France)

    2005-06-01

    Very precise combined work between multidisciplinary partners (radiation engineers in physics, engineers in bio-mechanics, medical radiologists and orthopedic pediatric surgeons) lead to the concept and development of a new low dose radiation device named EOS. This device allows 3 main advantages: (1) thanks to the invention of Georges Charpak (Nobel Price 1992) who designed gaseous detectors for X-rays, the reduction of dose necessary to obtain a good image of skeletal system was 8 to 10 times less for 2D imaging, compared to the dose necessary to obtain a 3D reconstruction from CT scan cuts the reduction factor was 800 to 1000. (2) The accuracy of 3D reconstruction obtained is as good as a 3D reconstruction from CT scan cuts. (3) The patient in addition get its imaging in standing functional position thank to the X-rays obtained from head to feet simultaneously AP and lateral. This is a big advantage compared to CT scan used only in lying position. From this simultaneous AP and lateral X-rays of the whole body thanks to the 3D bone external envelop technique, the engineers in bio-mechanics allowed to obtain 3D reconstruction of every level of osteo-articular system in standing position with an acceptable period of time (15 to 30 minutes). This (in spite of the evolution of standing MRI) allows more precise bone reconstruction in orthopedics especially at the level of spine, lower limbs, etc. In addition the fact to study the entire skeleton in standing functional position instead of small segmented studies given by CT scan in lying position produce a real improvement as well for physiology as for pathology of bone and joints disorders and especially for spinal pathology. (author)

  16. Simplifying the Exploration of Volumetric Images: Development of a 3D User Interface for the Radiologist’s Workplace

    OpenAIRE

    Teistler, M.; Breiman, R. S.; Lison, T.; Bott, O. J.; Pretschner, D. P.; Aziz, A.; Nowinski, W. L.

    2007-01-01

    Volumetric imaging (computed tomography and magnetic resonance imaging) provides increased diagnostic detail but is associated with the problem of navigation through large amounts of data. In an attempt to overcome this problem, a novel 3D navigation tool has been designed and developed that is based on an alternative input device. A 3D mouse allows for simultaneous definition of position and orientation of orthogonal or oblique multiplanar reformatted images or slabs, which are presented wit...

  17. DNA origami design of 3D nanostructures

    DEFF Research Database (Denmark)

    Andersen, Ebbe Sloth; Nielsen, Morten Muhlig

    2009-01-01

    , several dedicated 3D editors for computer-aided design of DNA structures have been developed [4-7]. However, many of these tools are not efficient for designing DNA origami structures that requires the design of more than 200 unique DNA strands to be folded along a scaffold strand into a defined 3D shape...... [8]. We have recently developed a semi-automated DNA origami software package [9] that uses a 2D sequence editor in conjunction with several automated tools to facilitate the design process. Here we extend the use of the program for designing DNA origami structures in 3D and show the application...... by the construction of a DNA box with dimensions of 42 × 36 × 36 nm3. The software is available at www.cdna.dk/origami/ ....

  18. A Simple Interface for 3D Position Estimation of a Mobile Robot with Single Camera.

    Science.gov (United States)

    Chao, Chun-Tang; Chung, Ming-Hsuan; Chiou, Juing-Shian; Wang, Chi-Jo

    2016-03-25

    In recent years, there has been an increase in the number of mobile robots controlled by a smart phone or tablet. This paper proposes a visual control interface for a mobile robot with a single camera to easily control the robot actions and estimate the 3D position of a target. In this proposal, the mobile robot employed an Arduino Yun as the core processor and was remote-controlled by a tablet with an Android operating system. In addition, the robot was fitted with a three-axis robotic arm for grasping. Both the real-time control signal and video transmission are transmitted via Wi-Fi. We show that with a properly calibrated camera and the proposed prototype procedures, the users can click on a desired position or object on the touchscreen and estimate its 3D coordinates in the real world by simple analytic geometry instead of a complicated algorithm. The results of the measurement verification demonstrates that this approach has great potential for mobile robots.

  19. Fabricating 3D figurines with personalized faces.

    Science.gov (United States)

    Tena, J Rafael; Mahler, Moshe; Beeler, Thabo; Grosse, Max; Hengchin Yeh; Matthews, Iain

    2013-01-01

    We present a semi-automated system for fabricating figurines with faces that are personalised to the individual likeness of the customer. The efficacy of the system has been demonstrated by commercial deployments at Walt Disney World Resort and Star Wars Celebration VI in Orlando Florida. Although the system is semi automated, human intervention is limited to a few simple tasks to maintain the high throughput and consistent quality required for commercial application. In contrast to existing systems that fabricate custom heads that are assembled to pre-fabricated plastic bodies, our system seamlessly integrates 3D facial data with a predefined figurine body into a unique and continuous object that is fabricated as a single piece. The combination of state-of-the-art 3D capture, modelling, and printing that are the core of our system provide the flexibility to fabricate figurines whose complexity is only limited by the creativity of the designer.

  20. Coping, goal adjustment, and positive and negative affect in definitive infertility

    NARCIS (Netherlands)

    Kraaij, V.; Garnefski, N.; Schroevers, M.J.

    2009-01-01

    The relationships between coping strategies, goal adjustment and positive and negative affect were studied in 83 definitive involuntary childless people. Self-report questionnaires were filled out. The findings suggested that positive ways to handle the childlessness were related to positive affect,

  1. 3-D discrete analytical ridgelet transform.

    Science.gov (United States)

    Helbert, David; Carré, Philippe; Andres, Eric

    2006-12-01

    In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines: 3-D discrete radial lines going through the origin defined from their orthogonal projections and 3-D planes covered with 2-D discrete line segments. These discrete analytical lines have a parameter called arithmetical thickness, allowing us to define a 3-D DART adapted to a specific application. Indeed, the 3-D DART representation is not orthogonal, It is associated with a flexible redundancy factor. The 3-D DART has a very simple forward/inverse algorithm that provides an exact reconstruction without any iterative method. In order to illustrate the potentiality of this new discrete transform, we apply the 3-D DART and its extension to the Local-DART (with smooth windowing) to the denoising of 3-D image and color video. These experimental results show that the simple thresholding of the 3-D DART coefficients is efficient.

  2. Invariant and semi-invariant probabilistic normed spaces

    Energy Technology Data Exchange (ETDEWEB)

    Ghaemi, M.B. [School of Mathematics Iran, University of Science and Technology, Narmak, Tehran (Iran, Islamic Republic of)], E-mail: mghaemi@iust.ac.ir; Lafuerza-Guillen, B. [Departamento de Estadistica y Matematica Aplicada, Universidad de Almeria, Almeria E-04120 (Spain)], E-mail: blafuerz@ual.es; Saiedinezhad, S. [School of Mathematics Iran, University of Science and Technology, Narmak, Tehran (Iran, Islamic Republic of)], E-mail: ssaiedinezhad@yahoo.com

    2009-10-15

    Probabilistic metric spaces were introduced by Karl Menger. Alsina, Schweizer and Sklar gave a general definition of probabilistic normed space based on the definition of Menger . We introduce the concept of semi-invariance among the PN spaces. In this paper we will find a sufficient condition for some PN spaces to be semi-invariant. We will show that PN spaces are normal spaces. Urysohn's lemma, and Tietze extension theorem for them are proved.

  3. A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser

    Science.gov (United States)

    Xi, Tong; Schreurs, Ruud; de Koning, Martien; Bergé, Stefaan; Maal, Thomas

    2016-01-01

    Aim The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery. Material and Method For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times. Results Low intra-observer and inter-observer variations in measurement error (mean error 0.97) were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively. Conclusion This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery

  4. A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser.

    Directory of Open Access Journals (Sweden)

    Frank Baan

    Full Text Available The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery.For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times.Low intra-observer and inter-observer variations in measurement error (mean error 0.97 were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively.This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery.

  5. Joint positions matter for ultrasound examination of RA patients-increased power Doppler signal in neutral versus flat position of hands.

    Science.gov (United States)

    Husic, Rusmir; Lackner, Angelika; Stradner, Martin H; Hermann, Josef; Dejaco, Christian

    2017-08-01

    Position of joints might influence the result of US examination in patients with RA. The purpose of this work was to compare grey-scale (GS) and power Doppler (PWD) findings obtained in neutral vs flat position of hands. A cross-sectional study of 42 RA patients with active disease. Two dimensional and 3D sonography of wrists and MCP joints were conducted in two different joint positions: neutral position, which is a slight flexion of the fingers with relaxed extensor muscles; and flat position, where all palm and volar sides of fingers touch the Table. Two dimensional GS synovitis (GSS) and PWD signals were scored semi-quantitatively (0-3). For 3D sonography, the percentage of PWD voxels within a region of interest was calculated. GSS was not quantified using 3D sonography. Compared with neutral position, 2D PWD signals disappeared in 28.3% of joints upon flattening. The median global 2D PWD score (sum of all PWD scores of an individual patient) decreased from 8 to 3 ( P < 0.001), and the global 3D PWD voxel score from 3.8 to 0.9 ( P < 0.001). The reduction of PWD scores was similar in all joints (2D: minus 50%, 3D: minus 66.4-80.1%). Inter- and intrareader agreement of PWD results was good (intraclass correlation coefficient: 0.75-0.82). In RA, a neutral position of the hands is linked to a higher sensitivity of 2D and 3D sonography in detecting PWD signals at wrists and MCP joints, compared with a flat position. Standardization of the scanning procedure is essential for obtaining comparable US results in RA patients in trials and clinical routines. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  6. a Statistical Analysis on the System Performance of a Bluetooth Low Energy Indoor Positioning System in a 3d Environment

    Science.gov (United States)

    Haagmans, G. G.; Verhagen, S.; Voûte, R. L.; Verbree, E.

    2017-09-01

    Since GPS tends to fail for indoor positioning purposes, alternative methods like indoor positioning systems (IPS) based on Bluetooth low energy (BLE) are developing rapidly. Generally, IPS are deployed in environments covered with obstacles such as furniture, walls, people and electronics influencing the signal propagation. The major factor influencing the system performance and to acquire optimal positioning results is the geometry of the beacons. The geometry of the beacons is limited to the available infrastructure that can be deployed (number of beacons, basestations and tags), which leads to the following challenge: Given a limited number of beacons, where should they be placed in a specified indoor environment, such that the geometry contributes to optimal positioning results? This paper aims to propose a statistical model that is able to select the optimal configuration that satisfies the user requirements in terms of precision. The model requires the definition of a chosen 3D space (in our case 7 × 10 × 6 meter), number of beacons, possible user tag locations and a performance threshold (e.g. required precision). For any given set of beacon and receiver locations, the precision, internal- and external reliability can be determined on forehand. As validation, the modeled precision has been compared with observed precision results. The measurements have been performed with an IPS of BlooLoc at a chosen set of user tag locations for a given geometric configuration. Eventually, the model is able to select the optimal geometric configuration out of millions of possible configurations based on a performance threshold (e.g. required precision).

  7. Precision 3d Surface Reconstruction from Lro Nac Images Using Semi-Global Matching with Coupled Epipolar Rectification

    Science.gov (United States)

    Hu, H.; Wu, B.

    2017-07-01

    The Narrow-Angle Camera (NAC) on board the Lunar Reconnaissance Orbiter (LRO) comprises of a pair of closely attached high-resolution push-broom sensors, in order to improve the swath coverage. However, the two image sensors do not share the same lenses and cannot be modelled geometrically using a single physical model. Thus, previous works on dense matching of stereo pairs of NAC images would generally create two to four stereo models, each with an irregular and overlapping region of varying size. Semi-Global Matching (SGM) is a well-known dense matching method and has been widely used for image-based 3D surface reconstruction. SGM is a global matching algorithm relying on global inference in a larger context rather than individual pixels to establish stable correspondences. The stereo configuration of LRO NAC images causes severe problem for image matching methods such as SGM, which emphasizes global matching strategy. Aiming at using SGM for image matching of LRO NAC stereo pairs for precision 3D surface reconstruction, this paper presents a coupled epipolar rectification methods for LRO NAC stereo images, which merges the image pair in the disparity space and in this way, only one stereo model will be estimated. For a stereo pair (four) of NAC images, the method starts with the boresight calibration by finding correspondence in the small overlapping stripe between each pair of NAC images and bundle adjustment of the stereo pair, in order to clean the vertical disparities. Then, the dominate direction of the images are estimated by project the center of the coverage area to the reference image and back-projected to the bounding box plane determined by the image orientation parameters iteratively. The dominate direction will determine an affine model, by which the pair of NAC images are warped onto the object space with a given ground resolution and in the meantime, a mask is produced indicating the owner of each pixel. SGM is then used to generate a disparity

  8. PRECISION 3D SURFACE RECONSTRUCTION FROM LRO NAC IMAGES USING SEMI-GLOBAL MATCHING WITH COUPLED EPIPOLAR RECTIFICATION

    Directory of Open Access Journals (Sweden)

    H. Hu

    2017-07-01

    Full Text Available The Narrow-Angle Camera (NAC on board the Lunar Reconnaissance Orbiter (LRO comprises of a pair of closely attached high-resolution push-broom sensors, in order to improve the swath coverage. However, the two image sensors do not share the same lenses and cannot be modelled geometrically using a single physical model. Thus, previous works on dense matching of stereo pairs of NAC images would generally create two to four stereo models, each with an irregular and overlapping region of varying size. Semi-Global Matching (SGM is a well-known dense matching method and has been widely used for image-based 3D surface reconstruction. SGM is a global matching algorithm relying on global inference in a larger context rather than individual pixels to establish stable correspondences. The stereo configuration of LRO NAC images causes severe problem for image matching methods such as SGM, which emphasizes global matching strategy. Aiming at using SGM for image matching of LRO NAC stereo pairs for precision 3D surface reconstruction, this paper presents a coupled epipolar rectification methods for LRO NAC stereo images, which merges the image pair in the disparity space and in this way, only one stereo model will be estimated. For a stereo pair (four of NAC images, the method starts with the boresight calibration by finding correspondence in the small overlapping stripe between each pair of NAC images and bundle adjustment of the stereo pair, in order to clean the vertical disparities. Then, the dominate direction of the images are estimated by project the center of the coverage area to the reference image and back-projected to the bounding box plane determined by the image orientation parameters iteratively. The dominate direction will determine an affine model, by which the pair of NAC images are warped onto the object space with a given ground resolution and in the meantime, a mask is produced indicating the owner of each pixel. SGM is then used to

  9. 3D-segmentation of the 18F-choline PET signal for target volume definition in radiation therapy of the prostate.

    Science.gov (United States)

    Ciernik, I Frank; Brown, Derek W; Schmid, Daniel; Hany, Thomas; Egli, Peter; Davis, J Bernard

    2007-02-01

    Volumetric assessment of PET signals becomes increasingly relevant for radiotherapy (RT) planning. Here, we investigate the utility of 18F-choline PET signals to serve as a structure for semi-automatic segmentation for forward treatment planning of prostate cancer. 18F-choline PET and CT scans of ten patients with histologically proven prostate cancer without extracapsular growth were acquired using a combined PET/CT scanner. Target volumes were manually delineated on CT images using standard software. Volumes were also obtained from 18F-choline PET images using an asymmetrical segmentation algorithm. PTVs were derived from CT 18F-choline PET based clinical target volumes (CTVs) by automatic expansion and comparative planning was performed. As a read-out for dose given to non-target structures, dose to the rectal wall was assessed. Planning target volumes (PTVs) derived from CT and 18F-choline PET yielded comparable results. Optimal matching of CT and 18F-choline PET derived volumes in the lateral and cranial-caudal directions was obtained using a background-subtracted signal thresholds of 23.0+/-2.6%. In antero-posterior direction, where adaptation compensating for rectal signal overflow was required, optimal matching was achieved with a threshold of 49.5+/-4.6%. 3D-conformal planning with CT or 18F-choline PET resulted in comparable doses to the rectal wall. Choline PET signals of the prostate provide adequate spatial information amendable to standardized asymmetrical region growing algorithms for PET-based target volume definition for external beam RT.

  10. Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software

    Energy Technology Data Exchange (ETDEWEB)

    Ebersberger, Ullrich [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Marcus, Roy P.; Nikolaou, Konstantin; Bamberg, Fabian [University of Munich, Institute of Clinical Radiology, Munich (Germany); Schoepf, U.J.; Gray, J.C.; McQuiston, Andrew D. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Lo, Gladys G. [Hong Kong Sanatorium and Hospital, Department of Diagnostic and Interventional Radiology, Hong Kong (China); Wang, Yining [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Department of Radiology, Beijing (China); Blanke, Philipp [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany); Geyer, Lucas L. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University of Munich, Institute of Clinical Radiology, Munich (Germany); Cho, Young Jun [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Konyang University College of Medicine, Department of Radiology, Daejeon (Korea, Republic of); Scheuering, Michael; Canstein, Christian [Siemens Healthcare, CT Division, Forchheim (Germany); Hoffmann, Ellen [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany)

    2014-01-15

    To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. (orig.)

  11. Optically directed molecular transport and 3D isoelectric positioning of amphoteric biomolecules

    International Nuclear Information System (INIS)

    Hafeman, Dean G.; Harkins, James B.; Witkowski, Charles E. II; Lewis, Nathan S.; Brown, Gilbert M.; Warmack, Robert J. Bruce; Thundat, Thomas George

    2006-01-01

    We demonstrate the formation of charged molecular packets and their transport within optically created electrical force-field traps in a pH-buffered electrolyte. We call this process photoelectrophoretic localization and transport (PELT). The electrolyte is in contact with a photoconductive semiconductor electrode and a counterelectrode that are connected through an external circuit. A light beam directed to coordinates on the photoconductive electrode surface produces a photocurrent within the circuit and electrolyte. Within the electrolyte, the photocurrent creates localized force-field traps centered at the illuminated coordinates. Charged molecules, including polypeptides and proteins, electrophoretically accumulate into the traps and subsequently can be transported in the electrolyte by moving the traps over the photoconductive electrode in response to movement of the light beam. The molecules in a single trap can be divided into aliquots, and the aliquots can be directed along multiple routes simultaneously by using multiple light beams. This photoelectrophoretic transport of charged molecules by PELT resembles the electrostatic transport of electrons within force-field wells of solid-state charge-coupled devices. The molecules, however, travel in a liquid electrolyte rather than a solid. Furthermore, we have used PELT to position amphoteric biomolecules in three dimensions. A 3D pH gradient was created in an electrolyte medium by controlling the illumination position on a photoconductive anode where protons were generated electrolytically. Photoelectrophoretic transport of amphoteric molecules through the pH gradient resulted in accumulation of the molecules at their apparent 3D isoelectric coordinates in the medium.

  12. Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design : A three-step study

    NARCIS (Netherlands)

    de Kleijn, Bertram J; Kraeima, Joep; Wachters, Jasper E; van der Laan, Bernard F A M; Wedman, Jan; Witjes, M J H; Halmos, Gyorgy B

    AIM: We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position. MATERIALS AND METHODS: 3D models of commercially available cannula were positioned in 3D models of the

  13. Automatic multi-camera calibration for deployable positioning systems

    Science.gov (United States)

    Axelsson, Maria; Karlsson, Mikael; Rudner, Staffan

    2012-06-01

    Surveillance with automated positioning and tracking of subjects and vehicles in 3D is desired in many defence and security applications. Camera systems with stereo or multiple cameras are often used for 3D positioning. In such systems, accurate camera calibration is needed to obtain a reliable 3D position estimate. There is also a need for automated camera calibration to facilitate fast deployment of semi-mobile multi-camera 3D positioning systems. In this paper we investigate a method for automatic calibration of the extrinsic camera parameters (relative camera pose and orientation) of a multi-camera positioning system. It is based on estimation of the essential matrix between each camera pair using the 5-point method for intrinsically calibrated cameras. The method is compared to a manual calibration method using real HD video data from a field trial with a multicamera positioning system. The method is also evaluated on simulated data from a stereo camera model. The results show that the reprojection error of the automated camera calibration method is close to or smaller than the error for the manual calibration method and that the automated calibration method can replace the manual calibration.

  14. Comparative evaluation of HD 2D/3D laparoscopic monitors and benchmarking to a theoretically ideal 3D pseudodisplay: even well-experienced laparoscopists perform better with 3D.

    Science.gov (United States)

    Wilhelm, D; Reiser, S; Kohn, N; Witte, M; Leiner, U; Mühlbach, L; Ruschin, D; Reiner, W; Feussner, H

    2014-08-01

    Though theoretically superior to standard 2D visualization, 3D video systems have not yet achieved a breakthrough in laparoscopy. The latest 3D monitors, including autostereoscopic displays and high-definition (HD) resolution, are designed to overcome the existing limitations. We performed a randomized study on 48 individuals with different experience levels in laparoscopy. Three different 3D displays (glasses-based 3D monitor, autostereoscopic display, and a mirror-based theoretically ideal 3D display) were compared to a 2D HD display by assessing multiple performance and mental workload parameters and rating the subjects during a laparoscopic suturing task. Electromagnetic tracking provided information on the instruments' pathlength, movement velocity, and economy. The usability, the perception of visual discomfort, and the quality of image transmission of each monitor were subjectively rated. Almost all performance parameters were superior with the conventional glasses-based 3D display compared to the 2D display and the autostereoscopic display, but were often significantly exceeded by the mirror-based 3D display. Subjects performed a task faster and with greater precision when visualization was achieved with the 3D and the mirror-based display. Instrument pathlength was shortened by improved depth perception. Workload parameters (NASA TLX) did not show significant differences. Test persons complained of impaired vision while using the autostereoscopic monitor. The 3D and 2D displays were rated user-friendly and applicable in daily work. Experienced and inexperienced laparoscopists profited equally from using a 3D display, with an improvement in task performance about 20%. Novel 3D displays improve laparoscopic interventions as a result of faster performance and higher precision without causing a higher mental workload. Therefore, they have the potential to significantly impact the further development of minimally invasive surgery. However, as shown by the

  15. Axionic D3-D7 Inflation

    CERN Document Server

    Burgess, C P; Postma, M

    2009-01-01

    We study the motion of a D3 brane moving within a Type IIB string vacuum compactified to 4D on K3 x T_2/Z_2 in the presence of D7 and O7 planes. We work within the effective 4D supergravity describing how the mobile D3 interacts with the lightest bulk moduli of the compactification, including the effects of modulus-stabilizing fluxes. We seek inflationary solutions to the resulting equations, performing our search numerically in order to avoid resorting to approximate parameterizations of the low-energy potential. We consider uplifting from D-terms and from the supersymmetry-breaking effects of anti-D3 branes. We find examples of slow-roll inflation (with anti-brane uplifting) with the mobile D3 moving along the toroidal directions, falling towards a D7-O7 stack starting from the antipodal point. The inflaton turns out to be a linear combination of the brane position and the axionic partner of the K3 volume modulus, and the similarity of the potential along the inflaton direction with that of racetrack inflat...

  16. Fixing D7-brane positions by F-theory fluxes

    International Nuclear Information System (INIS)

    Braun, A.P.; Hebecker, A.; Luedeling, C.; Valandro, R.

    2009-01-01

    To do realistic model building in type IIB supergravity, it is important to understand how to fix D7-brane positions by the choice of fluxes. More generally, F-theory model building requires the understanding of how fluxes determine the singularity structure (and hence gauge group and matter content) of the compactification. We analyse this problem in the simple setting of M-theory on K3xK3. Given a certain flux which is consistent with the F-theory limit, we can explicitly derive the positions at which D7 branes or stacks of D7 branes are stabilised. The analysis is based on a parameterization of the moduli space of type IIB string theory on T 2 /Z 2 (including D7-brane positions) in terms of the periods of integral cycles of M-theory on K3. This allows us, in particular, to select a specific desired gauge group by the choice of flux numbers.

  17. No-infill 3D Printing

    Science.gov (United States)

    Wei, Xiao-Ran; Zhang, Yu-He; Geng, Guo-Hua

    2016-09-01

    In this paper, we examined how printing the hollow objects without infill via fused deposition modeling, one of the most widely used 3D-printing technologies, by partitioning the objects to shell parts. More specifically, we linked the partition to the exact cover problem. Given an input watertight mesh shape S, we developed region growing schemes to derive a set of surfaces that had inside surfaces that were printable without support on the mesh for the candidate parts. We then employed Monte Carlo tree search over the candidate parts to obtain the optimal set cover. All possible candidate subsets of exact cover from the optimal set cover were then obtained and the bounded tree was used to search the optimal exact cover. We oriented each shell part to the optimal position to guarantee the inside surface was printed without support, while the outside surface was printed with minimum support. Our solution can be applied to a variety of models, closed-hollowed or semi-closed, with or without holes, as evidenced by experiments and performance evaluation on our proposed algorithm.

  18. Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design: a three-step study.

    Science.gov (United States)

    de Kleijn, Bertram J; Kraeima, Joep; Wachters, Jasper E; van der Laan, Bernard F A M; Wedman, Jan; Witjes, M J H; Halmos, Gyorgy B

    2018-02-01

    We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position. 3D models of commercially available cannula were positioned in 3D models of the airway. In study (1), a cohort that underwent tracheostomy between 2013 and 2015 was selected (n = 26). The cannula was virtually placed in the airway in the pre-operative CT scan and its position was compared to the cannula position on post-operative CT scans. In study (2), a cohort with neuromuscular disease (n = 14) was analyzed. Virtual cannula placing was performed in CT scans and tested if problems could be anticipated. Finally (3), for a patient with Duchenne muscular dystrophy and complications of conventional tracheostomy cannula, a patient-specific cannula was 3D designed, fabricated, and placed. (1) The 3D planned and post-operative tracheostomy position differed significantly. (2) Three groups of patients were identified: (A) normal anatomy; (B) abnormal anatomy, commercially available cannula fits; and (C) abnormal anatomy, custom-made cannula, may be necessary. (3) The position of the custom-designed cannula was optimal and the trachea healed. Virtual planning of the tracheostomy did not correlate with actual cannula position. Identifying patients with abnormal airway anatomy in whom commercially available cannula cannot be optimally positioned is advantageous. Patient-specific cannula design based on 3D virtualization of the airway was beneficial in a patient with abnormal airway anatomy.

  19. WLAN Fingerprint Indoor Positioning Strategy Based on Implicit Crowdsourcing and Semi-Supervised Learning

    Directory of Open Access Journals (Sweden)

    Chunjing Song

    2017-11-01

    Full Text Available Wireless local area network (WLAN fingerprint positioning is an indoor localization technique with high accuracy and low hardware requirements. However, collecting received signal strength (RSS samples for the fingerprint database is time-consuming and labor-intensive, hindering the use of this technique. The popular crowdsourcing sampling technique has been introduced to reduce the workload of sample collection, but has two challenges: one is the heterogeneity of devices, which can significantly affect the positioning accuracy; the other is the requirement of users’ intervention in traditional crowdsourcing, which reduces the practicality of the system. In response to these challenges, we have proposed a new WLAN indoor positioning strategy, which incorporates a new preprocessing method for RSS samples, the implicit crowdsourcing sampling technique, and a semi-supervised learning algorithm. First, implicit crowdsourcing does not require users’ intervention. The acquisition program silently collects unlabeled samples, the RSS samples, without information about the position. Secondly, to cope with the heterogeneity of devices, the preprocessing method maps all the RSS values of samples to a uniform range and discretizes them. Finally, by using a large number of unlabeled samples with some labeled samples, Co-Forest, the introduced semi-supervised learning algorithm, creates and repeatedly refines a random forest ensemble classifier that performs well for location estimation. The results of experiments conducted in a real indoor environment show that the proposed strategy reduces the demand for large quantities of labeled samples and achieves good positioning accuracy.

  20. Covariant loops and strings in a positive definite Hilbert space

    International Nuclear Information System (INIS)

    Rohrlich, F.

    1977-01-01

    Relativistic loops and strings are defined in the conventional way as solutions of a one-dimensional wave equation with certain boundary conditions and satisfying the orthogonal gauge conditions. Conventional pseudo-Cartesian co-ordinates (rather than null-plane co-ordinates) are used. The creation and annihilation operator four-vector αsub(μ)sup(+) and αsub(m) are required to be spacelike (orthogonal to the total momentum Psup(μ), so that the resulting Fock space is positive definite. This requirements is shown to be mathematically consistent with Poincare' invariance and to impose no additional physical constraints on the system. It can be implemented in a canonical realization of the Poincare' algebra as a condition on a state vectors, or in a noncanonical realization as an operator equation, as is done here. The space is further restricted by the Virasoro conditions to a physical subspace PHI which is of course also positive definite. In this way there arises no critical-dimension problem and Poincare' invariance holds also in 3+1 dimensions. The energy and spin spectra are the same as usual, leading to linear Regge trajectories, except that there are no tachyons and no zero mass states. The leading Regge trajectory has negative intercept

  1. 3D gaze tracking system for NVidia 3D Vision®.

    Science.gov (United States)

    Wibirama, Sunu; Hamamoto, Kazuhiko

    2013-01-01

    Inappropriate parallax setting in stereoscopic content generally causes visual fatigue and visual discomfort. To optimize three dimensional (3D) effects in stereoscopic content by taking into account health issue, understanding how user gazes at 3D direction in virtual space is currently an important research topic. In this paper, we report the study of developing a novel 3D gaze tracking system for Nvidia 3D Vision(®) to be used in desktop stereoscopic display. We suggest an optimized geometric method to accurately measure the position of virtual 3D object. Our experimental result shows that the proposed system achieved better accuracy compared to conventional geometric method by average errors 0.83 cm, 0.87 cm, and 1.06 cm in X, Y, and Z dimensions, respectively.

  2. 19 CFR 210.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Definitions. 210.3 Section 210.3 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Rules of General Applicability § 210.3 Definitions. As used in this part...

  3. Criterion of Semi-Markov Dependent Risk Model

    Institute of Scientific and Technical Information of China (English)

    Xiao Yun MO; Xiang Qun YANG

    2014-01-01

    A rigorous definition of semi-Markov dependent risk model is given. This model is a generalization of the Markov dependent risk model. A criterion and necessary conditions of semi-Markov dependent risk model are obtained. The results clarify relations between elements among semi-Markov dependent risk model more clear and are applicable for Markov dependent risk model.

  4. A Simple Interface for 3D Position Estimation of a Mobile Robot with Single Camera

    Directory of Open Access Journals (Sweden)

    Chun-Tang Chao

    2016-03-01

    Full Text Available In recent years, there has been an increase in the number of mobile robots controlled by a smart phone or tablet. This paper proposes a visual control interface for a mobile robot with a single camera to easily control the robot actions and estimate the 3D position of a target. In this proposal, the mobile robot employed an Arduino Yun as the core processor and was remote-controlled by a tablet with an Android operating system. In addition, the robot was fitted with a three-axis robotic arm for grasping. Both the real-time control signal and video transmission are transmitted via Wi-Fi. We show that with a properly calibrated camera and the proposed prototype procedures, the users can click on a desired position or object on the touchscreen and estimate its 3D coordinates in the real world by simple analytic geometry instead of a complicated algorithm. The results of the measurement verification demonstrates that this approach has great potential for mobile robots.

  5. 24 CFR 597.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Definitions. 597.3 Section 597.3... COMMUNITY FACILITIES URBAN EMPOWERMENT ZONES AND ENTERPRISE COMMUNITIES: ROUND ONE DESIGNATIONS General Provisions § 597.3 Definitions. The terms HUD and Secretary are defined in 24 CFR part 5. Designation means...

  6. Extendable linearised adjustment model for deformation analysis

    NARCIS (Netherlands)

    Hiddo Velsink

    2015-01-01

    Author supplied: "This paper gives a linearised adjustment model for the affine, similarity and congruence transformations in 3D that is easily extendable with other parameters to describe deformations. The model considers all coordinates stochastic. Full positive semi-definite covariance matrices

  7. Extendable linearised adjustment model for deformation analysis

    NARCIS (Netherlands)

    Velsink, H.

    2015-01-01

    This paper gives a linearised adjustment model for the affine, similarity and congruence transformations in 3D that is easily extendable with other parameters to describe deformations. The model considers all coordinates stochastic. Full positive semi-definite covariance matrices and correlation

  8. 14 CFR 99.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Definitions. 99.3 Section 99.3 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.3 Definitions. Aeronautical facility...

  9. Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data.

    Science.gov (United States)

    Forsberg, Daniel; Lindblom, Maria; Quick, Petter; Gauffin, Håkan

    2016-09-01

    To present a semi-automatic method with minimal user interaction for quantitative analysis of the patellofemoral motion pattern. 4D CT data capturing the patellofemoral motion pattern of a continuous flexion and extension were collected for five patients prone to patellar luxation both pre- and post-surgically. For the proposed method, an observer would place landmarks in a single 3D volume, which then are automatically propagated to the other volumes in a time sequence. From the landmarks in each volume, the measures patellar displacement, patellar tilt and angle between femur and tibia were computed. Evaluation of the observer variability showed the proposed semi-automatic method to be favorable over a fully manual counterpart, with an observer variability of approximately 1.5[Formula: see text] for the angle between femur and tibia, 1.5 mm for the patellar displacement, and 4.0[Formula: see text]-5.0[Formula: see text] for the patellar tilt. The proposed method showed that surgery reduced the patellar displacement and tilt at maximum extension with approximately 10-15 mm and 15[Formula: see text]-20[Formula: see text] for three patients but with less evident differences for two of the patients. A semi-automatic method suitable for quantification of the patellofemoral motion pattern as captured by 4D CT data has been presented. Its observer variability is on par with that of other methods but with the distinct advantage to support continuous motions during the image acquisition.

  10. DNA origami design of 3D nanostructures

    DEFF Research Database (Denmark)

    Andersen, Ebbe Sloth; Nielsen, Morten Muhlig

    2009-01-01

    [8]. We have recently developed a semi-automated DNA origami software package [9] that uses a 2D sequence editor in conjunction with several automated tools to facilitate the design process. Here we extend the use of the program for designing DNA origami structures in 3D and show the application......Structural DNA nanotechnology has been heavily dependent on the development of dedicated software tools for the design of unique helical junctions, to define unique sticky-ends for tile assembly, and for predicting the products of the self-assembly reaction of multiple DNA strands [1-3]. Recently......, several dedicated 3D editors for computer-aided design of DNA structures have been developed [4-7]. However, many of these tools are not efficient for designing DNA origami structures that requires the design of more than 200 unique DNA strands to be folded along a scaffold strand into a defined 3D shape...

  11. 45 CFR 60.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Definitions. 60.3 Section 60.3 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION NATIONAL PRACTITIONER DATA BANK FOR ADVERSE INFORMATION ON PHYSICIANS AND OTHER HEALTH CARE PRACTITIONERS General Provisions § 60.3 Definitions. Act means...

  12. 29 CFR 1405.3 - Definition.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Definition. 1405.3 Section 1405.3 Labor Regulations Relating to Labor (Continued) FEDERAL MEDIATION AND CONCILIATION SERVICE PART-TIME EMPLOYMENT General § 1405.3 Definition. Part-time career employment means regularly scheduled work of from 16 to 32 hours...

  13. 10 CFR 830.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... structures, systems, and components; (3) Safety management programs; (4) Technical safety requirements; and..., construction, fabrication, assembly, decontamination, environmental restoration, waste management, laboratory... ENERGY NUCLEAR SAFETY MANAGEMENT § 830.3 Definitions. (a) The following definitions apply to this part...

  14. 33 CFR 133.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... Contingency Plan”, “navigable waters”, “oil”, “remove”, “removal”, “removal costs”, “responsible party... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Definitions. 133.3 Section 133.3... FINANCIAL RESPONSIBILITY AND COMPENSATION OIL SPILL LIABILITY TRUST FUND; STATE ACCESS § 133.3 Definitions...

  15. 16 CFR 1401.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Definitions. 1401.3 Section 1401.3... TECHNICAL DATA § 1401.3 Definitions. For the purposes of this part 1401: (a) Chlorofluorocarbon means any... product across state lines from a contract filler to the marketer of the product would not constitute...

  16. 20 CFR 361.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Definitions. 361.3 Section 361.3 Employees... THE UNITED STATES GOVERNMENT BY GOVERNMENT EMPLOYEES § 361.3 Definitions. For purposes of this part... guaranteed by the United States and all other amounts due the United States from fees, leases, rents...

  17. 12 CFR 1780.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Definitions. 1780.3 Section 1780.3 Banks and Banking OFFICE OF FEDERAL HOUSING ENTERPRISE OVERSIGHT, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT RULES OF PRACTICE AND PROCEDURE RULES OF PRACTICE AND PROCEDURE General Rules § 1780.3 Definitions. For...

  18. 32 CFR 542.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Definitions. 542.3 Section 542.3 National Defense... Definitions. The following terms apply to the JROTC and NDCC programs: (a) Junior Reserve Officers' Training...) at public and private secondary schools to conduct student leadership training. Also, a general term...

  19. 28 CFR 41.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Definitions. 41.3 Section 41.3 Judicial... HANDICAP IN FEDERALLY ASSISTED PROGRAMS Federal Agency Responsibilities § 41.3 Definitions. As used in this regulation, the term: (a) Executive Order means Executive Order 12250, titled “Leadership and Coordination of...

  20. 10 CFR 781.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Definitions. 781.3 Section 781.3 Energy DEPARTMENT OF ENERGY DOE PATENT LICENSING REGULATIONS General Provisions § 781.3 Definitions. (a) Board means the... applicant means an applicant who, in the discretion of the Department, has the intention, plans, and ability...

  1. Using an effective dimensionality to map the force-extension relation for a semi-flexible polymer in a nanoslit

    Science.gov (United States)

    de Haan, Hendrick

    2015-03-01

    The force-extension relation for a semi-flexible polymer is well described by the Marko-Siggia equation in both two and three dimensions. However, while of interest for experimental systems such as DNA in nanopits, the behaviour between these limiting dimensionalities is less understood. I will present results from simulations of a polymer subject to a stretching force F confined in nanoslits of varying heights h. Going from the 3D case to the 2D case, both the coefficients of the equation and the relevant persistence length are shown to change. This observation leads to the definition of an effective dimensionality, deff, to characterize the system. At low F, using deff in a generalized form of the Marko-Siggia relation provides good agreement with the simulation curves. However, at high F, deff drifts back towards d = 3 . 0 . The reason behind this F dependence is discussed. Semi-empirical forms for strong and weak confinement regimes will be presented and shown to give good agreement across all slit heights and stretching forces. deff is thus dependent on h and F and provides a cohesive physical picture for all regimes.

  2. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    Science.gov (United States)

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  3. 21 CFR 165.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Definitions. 165.3 Section 165.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION BEVERAGES General Provisions § 165.3 Definitions. (a) A lot is: (1) For purposes of determining...

  4. 32 CFR 155.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... to classified information needed in connection with his or her employment in the private sector; any... 32 National Defense 1 2010-07-01 2010-07-01 false Definitions. 155.3 Section 155.3 National... SECURITY CLEARANCE PROGRAM § 155.3 Definitions. (a) Applicant. Any U.S. citizen who holds or requires a...

  5. Positive solutions of boundary value problem for singular positone and semi-positone third-order difference equations

    Directory of Open Access Journals (Sweden)

    Gai Gongqi

    2011-01-01

    Full Text Available Abstract This article studies the boundary value problems for the third-order nonlinear singular difference equations Δ 3 u ( i - 2 + λ a ( i f ( i , u ( i = 0 , i ∈ [ 2 , T + 2 ] , satisfying five kinds of different boundary value conditions. This article shows the existence of positive solutions for positone and semi-positone type. The nonlinear term may be singular. Two examples are also given to illustrate the main results. The arguments are based upon fixed point theorems in a cone. MSC [2008]: 34B15; 39A10.

  6. Precipitation Processes Developed During ARM (1997), TOGA COARE (1992), GATE (1974), SCSMEX (1998), and KWAJEX (1999): Consistent 2D, Semi-3D and 3D Cloud Resolving Model Simulations

    Science.gov (United States)

    Tao, W-K.

    2003-01-01

    Real clouds and cloud systems are inherently three-dimensional (3D). Because of the limitations in computer resources, however, most cloud-resolving models (CRMs) today are still two-dimensional (2D). A few 3D CRMs have been used to study the response of clouds to large-scale forcing. In these 3D simulations, the model domain was small, and the integration time was 6 hours. Only recently have 3D experiments been performed for multi-day periods for tropical cloud systems with large horizontal domains at the National Center for Atmospheric Research (NACAR) and at NASA Goddard Space Flight Center . At Goddard, a 3D Goddard Cumulus Ensemble (GCE) model was used to simulate periods during TOGA COARE, SCSMEX and KWAJEX using 512 by 512 km domain (with 2 km resolution). The results indicate that surface precipitation and latent heating profiles are very similar between the 2D and 3D GCE model simulations. The reason for the strong similarity between the 2D and 3D CRM simulations is that the same observed large-scale advective tendencies of potential temperature, water vapor mixing ratio, and horizontal momentum were used as the main focusing in both the 2D and 3D models. Interestingly, the 2D and 3D versions of the CRM used at CSU showed significant differences in the rainfall and cloud statistics for three ARM cases. The major objectives of this paper are: (1) to assess the performance of the super-parameterization technique, (2) calculate and examine the surface energy (especially radiation) and water budgets, and (3) identify the differences and similarities in the organization and entrainment rates of convection between simulated 2D and 3D cloud systems.

  7. USER REQUIREMENTS GATHERING FOR 3D GEOGRAPHIC INFORMATION IN THE UNITED KINGDOM

    Directory of Open Access Journals (Sweden)

    K. Wong

    2017-10-01

    Full Text Available Despite significant developments, 3D technologies are still not fully exploited in practice due to the lack of awareness as well as the lack of understanding of who the users of 3D will be and what the user requirements are. From a National Mapping & Cadastral Agency and data acquisition perspective, each new 3D feature type and element within a feature added (such as doors, windows, chimneys, street lights requires additional processing and cost to create. There is therefore a need to understand the importance of different 3D features and components for different applications. This will allow the direction of capture effort towards items that will be relevant to a wide range of users, as well as to understand the current status of, and interest in, 3D at a national level. This paper reports the results of an initial requirements gathering exercise for 3D geographic information in the United Kingdom (UK. It describes a user-centred design approach where usability and user needs are given extensive attention at each stage of the design process. Web-based questionnaires and semi-structured face-to-face interviews were used as complementary data collection methods to understand the user needs. The results from this initial study showed that while some applications lead the field with a high adoption of 3D, others are laggards, predominantly from organisational inertia. While individuals may be positive about the use of 3D, many struggle to justify the value and business case for 3D GI. Further work is required to identify the specific geometric and semantic requirements for different applications and to repeat the study with a larger sample.

  8. User Requirements Gathering for 3d Geographic Information in the United Kingdom

    Science.gov (United States)

    Wong, K.; Ellul, C.

    2017-10-01

    Despite significant developments, 3D technologies are still not fully exploited in practice due to the lack of awareness as well as the lack of understanding of who the users of 3D will be and what the user requirements are. From a National Mapping & Cadastral Agency and data acquisition perspective, each new 3D feature type and element within a feature added (such as doors, windows, chimneys, street lights) requires additional processing and cost to create. There is therefore a need to understand the importance of different 3D features and components for different applications. This will allow the direction of capture effort towards items that will be relevant to a wide range of users, as well as to understand the current status of, and interest in, 3D at a national level. This paper reports the results of an initial requirements gathering exercise for 3D geographic information in the United Kingdom (UK). It describes a user-centred design approach where usability and user needs are given extensive attention at each stage of the design process. Web-based questionnaires and semi-structured face-to-face interviews were used as complementary data collection methods to understand the user needs. The results from this initial study showed that while some applications lead the field with a high adoption of 3D, others are laggards, predominantly from organisational inertia. While individuals may be positive about the use of 3D, many struggle to justify the value and business case for 3D GI. Further work is required to identify the specific geometric and semantic requirements for different applications and to repeat the study with a larger sample.

  9. 30 CFR 282.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... from such activity. Contingency Plan means a plan for action to be taken in emergency situations. Data... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Definitions. 282.3 Section 282.3 Mineral... CONTINENTAL SHELF FOR MINERALS OTHER THAN OIL, GAS, AND SULPHUR General § 282.3 Definitions. When used in this...

  10. 32 CFR 257.3 - Definition.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Definition. 257.3 Section 257.3 National Defense... SERVICE OF PROCESS § 257.3 Definition. Service of Process. When applied to the filing of a court action... delivery of a subpoena for any other reason whether or not the matter involves the United States. ...

  11. 21 CFR 340.3 - Definition.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Definition. 340.3 Section 340.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE STIMULANT DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE General Provisions § 340.3 Definition. As used in...

  12. Automatic detection of patient identification and positioning errors in radiotherapy treatment using 3D setup images

    OpenAIRE

    Jani, Shyam

    2015-01-01

    The success of modern radiotherapy treatment depends on the correct alignment of the radiation beams with the target region in the patient. In the conventional paradigm of image-guided radiation therapy, 2D or 3D setup images are taken immediately prior to treatment and are used by radiation therapy technologists to localize the patient to the same position as defined from the reference planning CT dataset. However, numerous reports in the literature have described errors during this step, wh...

  13. 40 CFR 716.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... SAFETY DATA REPORTING General Provisions § 716.3 Definitions. The definitions in section 3 of TSCA apply... product research and development, or as an intermediate. (2) Manufacture for commercial purposes also... commit financial resources toward the manufacture, importation, or processing of a substance or mixture...

  14. 10 CFR 1047.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Definitions. 1047.3 Section 1047.3 Energy DEPARTMENT OF... General Provisions § 1047.3 Definitions. (a) Act means section 161.k. of the Atomic Energy Act of 1954, as..., that indicates an intention to take a person into custody and that subjects the person to the control...

  15. Nonperturbative summation over 3D discrete topologies

    International Nuclear Information System (INIS)

    Freidel, Laurent; Louapre, David

    2003-01-01

    The group field theories realizing the sum over all triangulations of all topologies of 3D discrete gravity amplitudes are known to be nonuniquely Borel summable. We modify these models to construct a new group field theory which is proved to be uniquely Borel summable, defining in an unambiguous way a nonperturbative sum over topologies in the context of 3D dynamical triangulations and spin foam models. Moreover, we give some arguments to support the fact that, despite our modification, this new model is similar to the original one, and therefore could be taken as a definition of the sum over topologies of 3D quantum gravity amplitudes

  16. Cross-cultural comparison of successful aging definitions between Chinese and Hmong elders in the United States

    OpenAIRE

    Nguyen, Annie L.; Seal, David W.

    2014-01-01

    The purpose of the study was to elicit the definitions of successful aging according to Chinese and Hmong elders living in Milwaukee, WI. In-depth semi-structured interviews were conducted with 44 elders (Hmong n=21 and Chinese n=23). Findings show some similarities in the Chinese and Hmong elders’ definitions though specific cultural differences exist. Chinese elders emphasized physical health and mobility, mental health, positive attitudes, shedding responsibilities, positive family relatio...

  17. The virtual craniofacial patient: 3D jaw modeling and animation.

    Science.gov (United States)

    Enciso, Reyes; Memon, Ahmed; Fidaleo, Douglas A; Neumann, Ulrich; Mah, James

    2003-01-01

    In this paper, we present new developments in the area of 3D human jaw modeling and animation. CT (Computed Tomography) scans have traditionally been used to evaluate patients with dental implants, assess tumors, cysts, fractures and surgical procedures. More recently this data has been utilized to generate models. Researchers have reported semi-automatic techniques to segment and model the human jaw from CT images and manually segment the jaw from MRI images. Recently opto-electronic and ultrasonic-based systems (JMA from Zebris) have been developed to record mandibular position and movement. In this research project we introduce: (1) automatic patient-specific three-dimensional jaw modeling from CT data and (2) three-dimensional jaw motion simulation using jaw tracking data from the JMA system (Zebris).

  18. Novel 3D porous semi-IPN hydrogel scaffolds of silk sericin and poly(N-hydroxyethyl acrylamide for dermal reconstruction

    Directory of Open Access Journals (Sweden)

    S. Ross

    2017-09-01

    Full Text Available In this work, a novel semi-interpenetrating polymer network (semi-IPN hydrogel scaffold based on silk sericin (SS and poly(N-hydroxyethyl acrylamide (PHEA was successfully fabricated via conventional free-radical polymerization. The porous structure of the scaffolds was introduced using a lyophilization technique and the effect of cross-linker (XL on morphology, gelation time and physical properties of hydrogel scaffold was first studied. The results show that using low cross-linker content (0.125, 0.25 and 0.5 wt% XL produced flexible scaffolds and appropriate gelation times for fabricating the scaffold. Therefore, the polymerization system with a constant percentage of XL at 0.5 wt% was chosen to study further the effect of SS on the physical properties and cell culture of the scaffolds. It was observed that the hydrogel scaffold of PHEA without SS (PHEA/SS-0 had no cell proliferation, whereas hydrogel scaffolds with SS enhanced cell viability when compared to the positive control. The sample of PHEA/SS at 1.25 wt% of SS and 0.5 wt% of cross-linker was the most suitable for HFF-1 cells to migrate and cell proliferation due to possessing a connective porous structure, along with silk sericin. The results proved that this novel porous semi-IPN hydrogel has the potential to be used as dermal reconstruction scaffold.

  19. Thermal impedance at the interface of contacting bodies: 1-D examples solved by semi-derivatives

    Directory of Open Access Journals (Sweden)

    Hristov Jordan

    2012-01-01

    Full Text Available Simple 1-D semi-infinite heat conduction problems enable to demonstrate the potential of the fractional calculus in determination of transient thermal impedances of two bodies with different initial temperatures contacting at the interface ( x = 0 at t = 0 . The approach is purely analytic and uses only semi-derivatives (half-time and semi-integrals in the Riemann-Liouville sense. The example solved clearly reveals that the fractional calculus is more effective in calculation the thermal resistances than the entire domain solutions.

  20. 48 CFR 3.801 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... consistent with the amount normally paid for such services in the private sector. Recipient includes the... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Definitions. 3.801 Section... Federal Transactions 3.801 Definitions. As used in this subpart— Agency means executive agency as defined...

  1. 7 CFR 8.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Definitions. 8.3 Section 8.3 Agriculture Office of the Secretary of Agriculture 4-H CLUB NAME AND EMBLEM § 8.3 Definitions. 4-H Club Name and Emblem as used in this part means the emblem consisting of a green four-leaf clover with stem and the letter “H” in white...

  2. Nonlinear Semi-Supervised Metric Learning Via Multiple Kernels and Local Topology.

    Science.gov (United States)

    Li, Xin; Bai, Yanqin; Peng, Yaxin; Du, Shaoyi; Ying, Shihui

    2018-03-01

    Changing the metric on the data may change the data distribution, hence a good distance metric can promote the performance of learning algorithm. In this paper, we address the semi-supervised distance metric learning (ML) problem to obtain the best nonlinear metric for the data. First, we describe the nonlinear metric by the multiple kernel representation. By this approach, we project the data into a high dimensional space, where the data can be well represented by linear ML. Then, we reformulate the linear ML by a minimization problem on the positive definite matrix group. Finally, we develop a two-step algorithm for solving this model and design an intrinsic steepest descent algorithm to learn the positive definite metric matrix. Experimental results validate that our proposed method is effective and outperforms several state-of-the-art ML methods.

  3. 12 CFR 1777.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... definitions will apply: 1992 Act means the Federal Housing Enterprises Financial Safety and Soundness Act, 12... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Definitions. 1777.3 Section 1777.3 Banks and Banking OFFICE OF FEDERAL HOUSING ENTERPRISE OVERSIGHT, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT SAFETY...

  4. Semi-implicit surface tension formulation with a Lagrangian surface mesh on an Eulerian simulation grid

    KAUST Repository

    Schroeder, Craig

    2012-02-01

    We present a method for applying semi-implicit forces on a Lagrangian mesh to an Eulerian discretization of the Navier Stokes equations in a way that produces a sparse symmetric positive definite system. The resulting method has semi-implicit and fully-coupled viscosity, pressure, and Lagrangian forces. We apply our new framework for forces on a Lagrangian mesh to the case of a surface tension force, which when treated explicitly leads to a tight time step restriction. By applying surface tension as a semi-implicit Lagrangian force, the resulting method benefits from improved stability and the ability to take larger time steps. The resulting discretization is also able to maintain parasitic currents at low levels. © 2011.

  5. A semi-analytical study of positive corona discharge in wire–plane electrode configuration

    International Nuclear Information System (INIS)

    Yanallah, K; Pontiga, F; Chen, J H

    2013-01-01

    Wire-to-plane positive corona discharge in air has been studied using an analytical model of two species (electrons and positive ions). The spatial distributions of electric field and charged species are obtained by integrating Gauss's law and the continuity equations of species along the Laplacian field lines. The experimental values of corona current intensity and applied voltage, together with Warburg's law, have been used to formulate the boundary condition for the electron density on the corona wire. To test the accuracy of the model, the approximate electric field distribution has been compared with the exact numerical solution obtained from a finite element analysis. A parametrical study of wire-to-plane corona discharge has then been undertaken using the approximate semi-analytical solutions. Thus, the spatial distributions of electric field and charged particles have been computed for different values of the gas pressure, wire radius and electrode separation. Also, the two dimensional distribution of ozone density has been obtained using a simplified plasma chemistry model. The approximate semi-analytical solutions can be evaluated in a negligible computational time, yet provide precise estimates of corona discharge variables. (paper)

  6. A semi-analytical study of positive corona discharge in wire-plane electrode configuration

    Science.gov (United States)

    Yanallah, K.; Pontiga, F.; Chen, J. H.

    2013-08-01

    Wire-to-plane positive corona discharge in air has been studied using an analytical model of two species (electrons and positive ions). The spatial distributions of electric field and charged species are obtained by integrating Gauss's law and the continuity equations of species along the Laplacian field lines. The experimental values of corona current intensity and applied voltage, together with Warburg's law, have been used to formulate the boundary condition for the electron density on the corona wire. To test the accuracy of the model, the approximate electric field distribution has been compared with the exact numerical solution obtained from a finite element analysis. A parametrical study of wire-to-plane corona discharge has then been undertaken using the approximate semi-analytical solutions. Thus, the spatial distributions of electric field and charged particles have been computed for different values of the gas pressure, wire radius and electrode separation. Also, the two dimensional distribution of ozone density has been obtained using a simplified plasma chemistry model. The approximate semi-analytical solutions can be evaluated in a negligible computational time, yet provide precise estimates of corona discharge variables.

  7. The development of a cell-assembly for the treatment of irradiated fuels on a semi-industrial scale; Etude concernant la realisation d'un ensemble de cellules destinees a des traitements de combustibles irradies a l'echelle semi-industrielle

    Energy Technology Data Exchange (ETDEWEB)

    Faugeras, P; Couture, J; Lefort, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The main studies and experiments involved in the development of a cell-assembly for the treatment of irradiated fuels on a semi-industrial scale are described. It must be possible to modify or transform each of these cells without interrupting the rest of the pilot. A full-scale prototype cell (3 x 4 x 6 m) has been built with an {alpha}-protection independent of the {gamma}-protection. It features all the main characteristics: tightness to {gamma} losses, dense glass lighting, ventilation. This cell has made possible trials on transfer, remote-controls and tele-dismantling, as well as the development of new methods of rapidly connecting hydraulic circuits. In conclusion the final form is given of the cells selected for the pilot. (author) [French] Il est decrit les principales etudes et experiences faites en vue de la realisation d'un ensemble de cellules destinees a des traitements de combustibles irradies a l'echelle semi-industrielle. Chacune de ces cellules doit pouvoir etre modifiee ou transformee sans interrompre le reste du pilote. Une cellule prototype vraie grandeur (3x4x6 m) est construite avec une protection {alpha} independante de la protection {gamma}. Elle comporte tous les elements importants: porte {gamma} etanche, eclairage verre dense, ventilation. Cette cellule a permis des experiences de transferts de telemanipulateurs et de teledemontages, ainsi que la mise au point de nouveaux procedes de jonction rapide pour des circuits hydrauliques. En conclusion, on indique la forme definitive des cellules retenues pour le pilote. (auteur)

  8. 3D neuromelanin-sensitive magnetic resonance imaging with semi-automated volume measurement of the substantia nigra pars compacta for diagnosis of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Ogisu, Kimihiro; Shirato, Hiroki [Hokkaido University Graduate School of Medicine, Department of Radiology, Hokkaido (Japan); Kudo, Kohsuke; Sasaki, Makoto [Iwate Medical University, Division of Ultrahigh Field MRI, Iwate (Japan); Sakushima, Ken; Yabe, Ichiro; Sasaki, Hidenao [Hokkaido University Hospital, Department of Neurology, Hokkaido (Japan); Terae, Satoshi; Nakanishi, Mitsuhiro [Hokkaido University Hospital, Department of Radiology, Hokkaido (Japan)

    2013-06-15

    Neuromelanin-sensitive MRI has been reported to be used in the diagnosis of Parkinson's disease (PD), which results from loss of dopamine-producing cells in the substantia nigra pars compacta (SNc). In this study, we aimed to apply a 3D turbo field echo (TFE) sequence for neuromelanin-sensitive MRI and to evaluate the diagnostic performance of semi-automated method for measurement of SNc volume in patients with PD. We examined 18 PD patients and 27 healthy volunteers (control subjects). A 3D TFE technique with off-resonance magnetization transfer pulse was used for neuromelanin-sensitive MRI on a 3T scanner. The SNc volume was semi-automatically measured using a region-growing technique at various thresholds (ranging from 1.66 to 2.48), with the signals measured relative to that for the superior cerebellar peduncle. Receiver operating characteristic (ROC) analysis was performed at all thresholds. Intra-rater reproducibility was evaluated by intraclass correlation coefficient (ICC). The average SNc volume in the PD group was significantly smaller than that in the control group at all the thresholds (P < 0.01, student t test). At higher thresholds (>2.0), the area under the curve of ROC (Az) increased (0.88). In addition, we observed balanced sensitivity and specificity (0.83 and 0.85, respectively). At lower thresholds, sensitivity tended to increase but specificity reduced in comparison with that at higher thresholds. ICC was larger than 0.9 when the threshold was over 1.86. Our method can distinguish the PD group from the control group with high sensitivity and specificity, especially for early stage of PD. (orig.)

  9. 36 CFR 73.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Definitions. 73.3 Section 73... HERITAGE CONVENTION § 73.3 Definitions. Cultural Heritage—Article 1 of the Convention defines “Cultural..., art, or science; and Sites: works of man or the combined works of nature and of man, and areas...

  10. 16 CFR 1302.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... EXTREMELY FLAMMABLE CONTACT ADHESIVES § 1302.3 Definitions. (a) The definitions in section 3 of the Consumer Product Safety Act (15 U.S.C. 2052) apply to this part 1302. (b) The term extremely flammable contact... percentage of solids (10-30 percent by weight); and (4) Are substances that are non-aerosols and are free...

  11. The description of condyle position in disc displacement with reduction using Cone Beam Computed Tomography 3D radiographic analysis

    Directory of Open Access Journals (Sweden)

    Liana Rahmayani

    2009-07-01

    Full Text Available One of the temporomandibular joint disorders that mostly occurs is disc displacement with reduction. Disc displacement that causes the displacement of condyle position can be evaluated by using radiograph. The Cone Beam Computed Tomography (CBCT-3D is a radiograph equipment which is able to capture the condyle position from many directions. This research was aimed to see the condyle position in patients with disc displacement with reduction symptoms. This research was conducted to 11 patients with symptoms of disc displacement with reduction and 3 patients without symptoms of disc displacement with reduction as the counterpart. What was conducted to the sample was the radiographic imaging using CBCT-3D radiography, followed by measuring the joint space distance in the sagittal and coronal directions. The result of the research was analyzed using the T-test. Statistically, the result of the test showed a significant difference ( = 0.05 between patients with disc displacement with reduction symptoms and the patients without symptoms, in sagittal and coronal views. The conclusion led to the difference in condyle positions in patients with the disc displacement with reduction and patients without the symptoms which meant there was a condyle position displacement that caused the distance alteration in joint space in sagittal and coronal directions.

  12. Controlled Positioning of Cells in Biomaterials-Approaches Towards 3D Tissue Printing.

    Science.gov (United States)

    Wüst, Silke; Müller, Ralph; Hofmann, Sandra

    2011-08-04

    Current tissue engineering techniques have various drawbacks: they often incorporate uncontrolled and imprecise scaffold geometries, whereas the current conventional cell seeding techniques result mostly in random cell placement rather than uniform cell distribution. For the successful reconstruction of deficient tissue, new material engineering approaches have to be considered to overcome current limitations. An emerging method to produce complex biological products including cells or extracellular matrices in a controlled manner is a process called bioprinting or biofabrication, which effectively uses principles of rapid prototyping combined with cell-loaded biomaterials, typically hydrogels. 3D tissue printing is an approach to manufacture functional tissue layer-by-layer that could be transplanted in vivo after production. This method is especially advantageous for stem cells since a controlled environment can be created to influence cell growth and differentiation. Using printed tissue for biotechnological and pharmacological needs like in vitro drug-testing may lead to a revolution in the pharmaceutical industry since animal models could be partially replaced by biofabricated tissues mimicking human physiology and pathology. This would not only be a major advancement concerning rising ethical issues but would also have a measureable impact on economical aspects in this industry of today, where animal studies are very labor-intensive and therefore costly. In this review, current controlled material and cell positioning techniques are introduced highlighting approaches towards 3D tissue printing.

  13. Controlled Positioning of Cells in Biomaterials—Approaches Towards 3D Tissue Printing

    Directory of Open Access Journals (Sweden)

    Sandra Hofmann

    2011-08-01

    Full Text Available Current tissue engineering techniques have various drawbacks: they often incorporate uncontrolled and imprecise scaffold geometries, whereas the current conventional cell seeding techniques result mostly in random cell placement rather than uniform cell distribution. For the successful reconstruction of deficient tissue, new material engineering approaches have to be considered to overcome current limitations. An emerging method to produce complex biological products including cells or extracellular matrices in a controlled manner is a process called bioprinting or biofabrication, which effectively uses principles of rapid prototyping combined with cell-loaded biomaterials, typically hydrogels. 3D tissue printing is an approach to manufacture functional tissue layer-by-layer that could be transplanted in vivo after production. This method is especially advantageous for stem cells since a controlled environment can be created to influence cell growth and differentiation. Using printed tissue for biotechnological and pharmacological needs like in vitro drug-testing may lead to a revolution in the pharmaceutical industry since animal models could be partially replaced by biofabricated tissues mimicking human physiology and pathology. This would not only be a major advancement concerning rising ethical issues but would also have a measureable impact on economical aspects in this industry of today, where animal studies are very labor-intensive and therefore costly. In this review, current controlled material and cell positioning techniques are introduced highlighting approaches towards 3D tissue printing.

  14. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    International Nuclear Information System (INIS)

    Wilbert, Jürgen; Guckenberger, Matthias; Polat, Bülent; Sauer, Otto; Vogele, Michael; Flentje, Michael; Sweeney, Reinhart A

    2010-01-01

    To introduce a novel method of patient positioning for high precision intracranial radiotherapy. An infrared(IR)-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP) and connected to the table via a 6 degree-of-freedom(DoF) mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT) is performed. A robotic 6 DoF treatment couch (HexaPOD™) then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD) of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102) was 1.6 ± 0.8 mm while intra-fraction movement (n = 110) was 0.6 ± 0.4 mm. This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient comfort

  15. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    Directory of Open Access Journals (Sweden)

    Flentje Michael

    2010-05-01

    Full Text Available Abstract Background To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods An infrared(IR-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP and connected to the table via a 6 degree-of-freedom(DoF mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT is performed. A robotic 6 DoF treatment couch (HexaPOD™ then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102 was 1.6 ± 0.8 mm while intra-fraction movement (n = 110 was 0.6 ± 0.4 mm. Conclusions This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient

  16. Life sciences payload definition and integration study, task C and D. Volume 2: Payload definition, integration, and planning studies

    Science.gov (United States)

    1973-01-01

    The Life Sciences Payload Definition and Integration Study was composed of four major tasks. Tasks A and B, the laboratory definition phase, were the subject of prior NASA study. The laboratory definition phase included the establishment of research functions, equipment definitions, and conceptual baseline laboratory designs. These baseline laboratories were designated as Maxi-Nom, Mini-30, and Mini-7. The outputs of Tasks A and B were used by the NASA Life Sciences Payload Integration Team to establish guidelines for Tasks C and D, the laboratory integration phase of the study. A brief review of Tasks A and B is presented provide background continuity. The tasks C and D effort is the subject of this report. The Task C effort stressed the integration of the NASA selected laboratory designs with the shuttle sortie module. The Task D effort updated and developed costs that could be used by NASA for preliminary program planning.

  17. Rigid 3D-3D registration of TOF MRA integrating vessel segmentation for quantification of recurrence volumes after coiling cerebral aneurysm

    International Nuclear Information System (INIS)

    Saering, Dennis; Forkert, Nils Daniel; Fiehler, Jens; Ries, Thorsten

    2012-01-01

    A fast and reproducible quantification of the recurrence volume of coiled aneurysms is required to enable a more timely evaluation of new coils. This paper presents two registration schemes for the semi-automatic quantification of aneurysm recurrence volumes based on baseline and follow-up 3D MRA TOF datasets. The quantification of shape changes requires a previous definition of corresponding structures in both datasets. For this, two different rigid registration methods have been developed and evaluated. Besides a state-of-the-art rigid registration method, a second approach integrating vessel segmentations is presented. After registration, the aneurysm recurrence volume can be calculated based on the difference image. The computed volumes were compared to manually extracted volumes. An evaluation based on 20 TOF MRA datasets (baseline and follow-up) of ten patients showed that both registration schemes are generally capable of providing sufficient registration results. Regarding the quantification of aneurysm recurrence volumes, the results suggest that the second segmentation-based registration method yields better results, while a reduction of the computation and interaction time is achieved at the same time. The proposed registration scheme incorporating vessel segmentation enables an improved quantification of recurrence volumes of coiled aneurysms with reduced computation and interaction time. (orig.)

  18. 21 CFR 136.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... CONSUMPTION BAKERY PRODUCTS General Provisions § 136.3 Definitions. For purposes of this part, the following definitions apply: (a) The word bread when used in the name of the food means the unit weighs one-half pound...

  19. High-accuracy and real-time 3D positioning, tracking system for medical imaging applications based on 3D digital image correlation

    Science.gov (United States)

    Xue, Yuan; Cheng, Teng; Xu, Xiaohai; Gao, Zeren; Li, Qianqian; Liu, Xiaojing; Wang, Xing; Song, Rui; Ju, Xiangyang; Zhang, Qingchuan

    2017-01-01

    This paper presents a system for positioning markers and tracking the pose of a rigid object with 6 degrees of freedom in real-time using 3D digital image correlation, with two examples for medical imaging applications. Traditional DIC method was improved to meet the requirements of the real-time by simplifying the computations of integral pixel search. Experiments were carried out and the results indicated that the new method improved the computational efficiency by about 4-10 times in comparison with the traditional DIC method. The system was aimed for orthognathic surgery navigation in order to track the maxilla segment after LeFort I osteotomy. Experiments showed noise for the static point was at the level of 10-3 mm and the measurement accuracy was 0.009 mm. The system was demonstrated on skin surface shape evaluation of a hand for finger stretching exercises, which indicated a great potential on tracking muscle and skin movements.

  20. Semi-automatische Orbita-Segmentierung in CT-Bilddaten

    Directory of Open Access Journals (Sweden)

    Tingelhoff, Kathrin

    2009-08-01

    Full Text Available Die Segmentierung medizinischer Bilddaten gewinnt in vielen klinischen Bereichen an Bedeutung. Die Segmentierungsergebnisse können zur Diagnose, Operationsplanung oder Definition eines Arbeitsraumes für roboter-assistierte Systeme verwendet werden. In diesem Paper wird ein neues Verfahren zur semi-automatischen Orbita-Segmentierung mit minimalem Interaktionsaufwand vorgestellt. Die Ergebnisse der semi-automatischen Segmentierung haben wir mit der manuellen Segmentierung eines Experten in Bezug auf Volumen, Überlappungsmaße und Segmentierungszeit verglichen. Die Abweichung zwischen manueller und semi-automatischer Segmentierung beträgt durchschnittlich 3,29% des Volumens. Im Vergleich zur manuellen Segmentierung liegen die Ergebnisse deutlich unter den Schwankungen der interindividuellen Variabilität, daher ist dieses Verfahren der manuellen Segmentierung vorzuziehen. In unserer künftigen Arbeit möchten wir den Interaktionsaufwand sowie den Segmentierungsfehler weiter reduzieren. Zudem sollen die Einsatzmöglichkeiten des Verfahrens zur präoperativen Planung von Orbitarekonstruktionen evaluiert werden.

  1. Bayesian Reasoning Using 3D Relations for Lane Marker Detection

    DEFF Research Database (Denmark)

    Boesman, Bart; Jensen, Lars Baunegaard With; Baseski, Emre

    2009-01-01

    We introduce a lane marker detection algorithm that integrates 3D attributes as well as 3D relations between local edges and semi-global contours in a Bayesian framework. The algorithm is parameter free and does not make use of any heuristic assumptions. The reasoning is based on the complete...... to the reconstruction process need to be taken into account to make the reasoning process more stable. The results are shown on a publicly available data set....

  2. 3D Metallic Lattices for Accelerator Applications

    CERN Document Server

    Shapiro, Michael A; Sirigiri, Jagadishwar R; Temkin, Richard J

    2005-01-01

    We present the results of research on 3D metallic lattices operating at microwave frequencies for application in (1) accelerator structures with higher order mode suppression, (2) Smith-Purcell radiation beam diagnostics, and (3) polaritonic materials for laser acceleration. Electromagnetic waves in a 3D simple cubic lattice formed by metal wires are calculated using HFSS. The bulk modes in the lattice are determined using single cell calculations with different phase advances in all three directions. The Brillouin diagram for the bulk modes is presented and indicates the absence of band gaps in simple lattices except the band below the cutoff. Lattices with thin wires as well as with thick wires have been analyzed. The Brillouin diagram also indicates the presence of low frequency 3D plasmon mode as well as the two degenerate photon modes analogous to those in a 2D lattice. Surface modes for a semi-infinite cubic lattice are modeled as a stack of cells with different phase advances in the two directions alon...

  3. Positive definite functions and dual pairs of locally convex spaces

    Directory of Open Access Journals (Sweden)

    Daniel Alpay

    2018-01-01

    Full Text Available Using pairs of locally convex topological vector spaces in duality and topologies defined by directed families of sets bounded with respect to the duality, we prove general factorization theorems and general dilation theorems for operator-valued positive definite functions.

  4. 3D Rainbow Particle Tracking Velocimetry

    Science.gov (United States)

    Aguirre-Pablo, Andres A.; Xiong, Jinhui; Idoughi, Ramzi; Aljedaani, Abdulrahman B.; Dun, Xiong; Fu, Qiang; Thoroddsen, Sigurdur T.; Heidrich, Wolfgang

    2017-11-01

    A single color camera is used to reconstruct a 3D-3C velocity flow field. The camera is used to record the 2D (X,Y) position and colored scattered light intensity (Z) from white polyethylene tracer particles in a flow. The main advantage of using a color camera is the capability of combining different intensity levels for each color channel to obtain more depth levels. The illumination system consists of an LCD projector placed perpendicularly to the camera. Different intensity colored level gradients are projected onto the particles to encode the depth position (Z) information of each particle, benefiting from the possibility of varying the color profiles and projected frequencies up to 60 Hz. Chromatic aberrations and distortions are estimated and corrected using a 3D laser engraved calibration target. The camera-projector system characterization is presented considering size and depth position of the particles. The use of these components reduces dramatically the cost and complexity of traditional 3D-PTV systems.

  5. 26 CFR 1.854-3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Definitions. 1.854-3 Section 1.854-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Regulated Investment Companies and Real Estate Investment Trusts § 1.854-3 Definitions. (a) For...

  6. 3D visualization of medical images for personalized learning of human anatomy

    NARCIS (Netherlands)

    Laurence Alpay; Jelle Scheurleer; Harmen Bijwaard

    2015-01-01

    to be held in Lisbon/Portugal on October 15-17, 2015 Medical imaging nowadays often yields high definition 3D images (from CT, PET, MRI, etc.). Usually these images need to be evaluated on 2D monitors. In the transition from 3D to 2D the image becomes more difficult to interpret as a whole. To aid

  7. Gaze3DFix: Detecting 3D fixations with an ellipsoidal bounding volume.

    Science.gov (United States)

    Weber, Sascha; Schubert, Rebekka S; Vogt, Stefan; Velichkovsky, Boris M; Pannasch, Sebastian

    2017-10-26

    Nowadays, the use of eyetracking to determine 2-D gaze positions is common practice, and several approaches to the detection of 2-D fixations exist, but ready-to-use algorithms to determine eye movements in three dimensions are still missing. Here we present a dispersion-based algorithm with an ellipsoidal bounding volume that estimates 3D fixations. Therefore, 3D gaze points are obtained using a vector-based approach and are further processed with our algorithm. To evaluate the accuracy of our method, we performed experimental studies with real and virtual stimuli. We obtained good congruence between stimulus position and both the 3D gaze points and the 3D fixation locations within the tested range of 200-600 mm. The mean deviation of the 3D fixations from the stimulus positions was 17 mm for the real as well as for the virtual stimuli, with larger variances at increasing stimulus distances. The described algorithms are implemented in two dynamic linked libraries (Gaze3D.dll and Fixation3D.dll), and we provide a graphical user interface (Gaze3DFixGUI.exe) that is designed for importing 2-D binocular eyetracking data and calculating both 3D gaze points and 3D fixations using the libraries. The Gaze3DFix toolkit, including both libraries and the graphical user interface, is available as open-source software at https://github.com/applied-cognition-research/Gaze3DFix .

  8. Robust domain decomposition preconditioners for abstract symmetric positive definite bilinear forms

    KAUST Repository

    Efendiev, Yalchin; Galvis, Juan; Lazarov, Raytcho; Willems, Joerg

    2012-01-01

    An abstract framework for constructing stable decompositions of the spaces corresponding to general symmetric positive definite problems into "local" subspaces and a global "coarse" space is developed. Particular applications of this abstract

  9. 26 CFR 1.856-3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Definitions. 1.856-3 Section 1.856-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.856-3 Definitions. For purposes of the regulations under part II...

  10. Achievability of 3D planned bimaxillary osteotomies: maxilla-first versus mandible-first surgery.

    Science.gov (United States)

    Liebregts, Jeroen; Baan, Frank; de Koning, Martien; Ongkosuwito, Edwin; Bergé, Stefaan; Maal, Thomas; Xi, Tong

    2017-08-24

    The present study was aimed to investigate the effects of sequencing a two-component surgical procedure for correcting malpositioned jaws (bimaxillary osteotomies); specifically, surgical repositioning of the upper jaw-maxilla, and the lower jaw-mandible. Within a population of 116 patients requiring bimaxillary osteotomies, the investigators analyzed whether there were statistically significant differences in postoperative outcome as measured by concordance with a preoperative digital 3D virtual treatment plan. In one group of subjects (n = 58), the maxillary surgical procedure preceded the mandibular surgery. In the second group (n = 58), the mandibular procedure preceded the maxillary surgical procedure. A semi-automated analysis tool (OrthoGnathicAnalyser) was applied to assess the concordance of the postoperative maxillary and mandibular position with the cone beam CT-based 3D virtual treatment planning in an effort to minimize observer variability. The results demonstrated that in most instances, the maxilla-first surgical approach yielded closer concordance with the 3D virtual treatment plan than a mandibular-first procedure. In selected circumstances, such as a planned counterclockwise rotation of both jaws, the mandible-first sequence resulted in more predictable displacements of the jaws.

  11. Comparison of 3D cube FLAIR with 2D FLAIR for multiple sclerosis imaging at 3 tesla

    Energy Technology Data Exchange (ETDEWEB)

    Patzig, M.; Brueckmann, H.; Fesl, G. [Muenchen Univ. (Germany). Dept. of Neuroradiology; Burke, M. [GE Healthcare, Solingen (Germany)

    2014-05-15

    Purpose: Three-dimensional (3 D) MRI sequences allow improved spatial resolution with good signal and contrast properties as well as multiplanar reconstruction. We sought to compare Cube, a 3 D FLAIR sequence, to a standard 2 D FLAIR sequence in multiple sclerosis (MS) imaging. Materials and Methods: Examinations were performed in the clinical routine on a 3.0 Tesla scanner. 12 patients with definite MS were included. Lesions with MS-typical properties on the images of Cube FLAIR and 2 D FLAIR sequences were counted and allocated to different brain regions. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Results: With 384 the overall number of lesions found with Cube FLAIR was significantly higher than with 2 D FLAIR (N = 221). The difference was mostly accounted for by supratentorial lesions (N = 372 vs. N = 216) while the infratentorial lesion counts were low in both sequences. SNRs and CNRs were significantly higher in CUBE FLAIR with the exception of the CNR of lesion to gray matter, which was not significantly different. Conclusion: Cube FLAIR showed a higher sensitivity for MS lesions compared to a 2 D FLAIR sequence. 3 D FLAIR might replace 2 D FLAIR sequences in MS imaging in the future. (orig.)

  12. Shaping 3-D boxes

    DEFF Research Database (Denmark)

    Stenholt, Rasmus; Madsen, Claus B.

    2011-01-01

    Enabling users to shape 3-D boxes in immersive virtual environments is a non-trivial problem. In this paper, a new family of techniques for creating rectangular boxes of arbitrary position, orientation, and size is presented and evaluated. These new techniques are based solely on position data...

  13. 32 CFR 99.3 - General definitions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false General definitions. 99.3 Section 99.3 National... PROCEDURES FOR STATES AND LOCALITIES TO REQUEST INDEMNIFICATION § 99.3 General definitions. For the purposes of §§ 99.1 through 99.9 of this part: Criminal history record information: information collected by...

  14. 2D/3D/4D ULTRASOUND IN INFERTILITY MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Uršula Reš-Muravec

    2018-02-01

    Ultrasound in infertility diagnostics: Ultrasound is used for examination of uterus, tubes, ovaries and peritoneal cause of infertility. It can be used in different menstrual phases: proliferative, periovulatory and secretory phase. Examination of uterus: A 2D scan can measure the size of the uterus (length, width and depth and a 2D flow (colour and power doppler. With 3D technology we can measure the whole volume with VOCAL (virtual organ computer-aided analysis and 3D circulation with the index (VI – vascular index, FI – flow index and VFI – vascular flow index in the uterus. A 2D scan can help us define uterine malformations, fibroids and adenomyosis to a certain extent. However, a 3D scan offers more accurate diagnosis of these malformations. Endometrium is examined separately. With 2D the width is measured and morphology and focal lesions (polyp, fibroids, adhesions are examined. With 3D the real sagital plane for the width measurement can be defined . We can measure the volume of endometrium and subendometrium and 3D circulation in endometrium and subendometrium. The FIS (f luid instlation sonography is very useful when examining the endometrium; saline or gel can be used for uterine instalation. We can measure and define the position of the structures in the endometrium more accurately when they are surrouned by saline or gel. We can view these structures with a surface view, similar to the one used for hysteroscopy. With this information we can explain the pathology to the patient and easily plan the surgical procedures. Examination of the tubes: With 2D US we can see the tubes in the pelvis only if there are dilatations, but sometimes it is difficult to distinguish them from the neighbouring forma- tions. With a 3D ultrasound we can define the shape and continuity of the tube and we can view the tube from different angles (inversion mode. Different contrast media are used for determining tubal patency. Tubal patency can be diagnosed with 2D Hy

  15. A method for weighted projections to the positive definite cone

    KAUST Repository

    Valkonen, Tuomo

    2014-06-24

    © 2014 Taylor & Francis. We study the numerical solution of the problem (Formula presented.) , where (Formula presented.) is a symmetric square matrix, and (Formula presented.) is a linear operator, such that (Formula presented.) is invertible. With (Formula presented.) the desired fractional duality gap, and (Formula presented.) the condition number of (Formula presented.) , we prove (Formula presented.) iteration complexity for a simple primal-dual interior point method directly based on those for linear programs with semi-definite constraints. We do not, however, require the numerically expensive scalings inherent in these methods to force fast convergence. For low-dimensional problems (Formula presented.), our numerical experiments indicate excellent performance and only a very slowly growing dependence of the convergence rate on (Formula presented.). While our algorithm requires somewhat more iterations than existing interior point methods, the iterations are cheaper. This gives better computational times.

  16. A method for weighted projections to the positive definite cone

    KAUST Repository

    Valkonen, Tuomo

    2014-01-01

    © 2014 Taylor & Francis. We study the numerical solution of the problem (Formula presented.) , where (Formula presented.) is a symmetric square matrix, and (Formula presented.) is a linear operator, such that (Formula presented.) is invertible. With (Formula presented.) the desired fractional duality gap, and (Formula presented.) the condition number of (Formula presented.) , we prove (Formula presented.) iteration complexity for a simple primal-dual interior point method directly based on those for linear programs with semi-definite constraints. We do not, however, require the numerically expensive scalings inherent in these methods to force fast convergence. For low-dimensional problems (Formula presented.), our numerical experiments indicate excellent performance and only a very slowly growing dependence of the convergence rate on (Formula presented.). While our algorithm requires somewhat more iterations than existing interior point methods, the iterations are cheaper. This gives better computational times.

  17. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    Science.gov (United States)

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  18. 40 CFR 302.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... COMMUNITY RIGHT-TO-KNOW PROGRAMS DESIGNATION, REPORTABLE QUANTITIES, AND NOTIFICATION § 302.3 Definitions...); Administrator means the Administrator of the United States Environmental Protection Agency (“EPA”); Animal waste.... The definition includes animal waste when mixed or commingled with bedding, compost, feed, soil and...

  19. 12 CFR 1770.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... AND SOUNDNESS EXECUTIVE COMPENSATION § 1770.3 Definitions. The following definitions apply to the.... Compensation includes all direct and indirect payments of benefits, both cash and non-cash, granted to or for... from an employment contract compensation or benefit agreement, fee arrangement, perquisite, stock...

  20. Evaluating functions of positive-definite matrices using colored-noise thermostats

    Science.gov (United States)

    Nava, Marco; Ceriotti, Michele; Dryzun, Chaim; Parrinello, Michele

    2014-02-01

    Many applications in computational science require computing the elements of a function of a large matrix. A commonly used approach is based on the the evaluation of the eigenvalue decomposition, a task that, in general, involves a computing time that scales with the cube of the size of the matrix. We present here a method that can be used to evaluate the elements of a function of a positive-definite matrix with a scaling that is linear for sparse matrices and quadratic in the general case. This methodology is based on the properties of the dynamics of a multidimensional harmonic potential coupled with colored-noise, generalized Langevin equation thermostats. This "f-thermostat" approach allows us to calculate directly elements of functions of a positive-definite matrix by carefully tailoring the properties of the stochastic dynamics. We demonstrate the scaling and the accuracy of this approach for both dense and sparse problems and compare the results with other established methodologies.

  1. Adaptive interrogation for 3D-PIV

    International Nuclear Information System (INIS)

    Novara, Matteo; Scarano, Fulvio; Ianiro, Andrea

    2013-01-01

    A method to adapt the shape and orientation of interrogation volumes for 3D-PIV motion analysis is introduced, aimed to increase the local spatial resolution. The main application of this approach is the detailed analysis of complex 3D and vortex-dominated flows that exhibit high vorticity in confined regions like shear layers and vortex filaments. The adaptive criterion is based on the analysis of the components of the local velocity gradient tensor, which returns the level of anisotropy of velocity spatial fluctuations. The principle to increase the local spatial resolution is based on the deformation of spherical isotropic interrogation regions, obtained by means of Gaussian weighting, into ellipsoids, with free choice of the principal axes and their directions. The interrogation region is contracted in the direction of the maximum velocity variation and elongated in the minimum one in order to maintain a constant interrogation volume. The adaptivity technique for three-dimensional PIV data takes advantage of the 3D topology of the flow, allowing increasing the spatial resolution not only in the case of shear layers, but also for vortex filaments, which is not possible for two-dimensional measurement in the plane normal to the vortex axis. The definition of the ellipsoidal interrogation region semi-axes is based on the singular values and singular directions of the local velocity gradient tensor as obtained by the singular values decomposition technique (SVD). The working principle is verified making use of numerical simulations of a shear layer and of a vortex filament. The application of the technique to data from a Tomo-PIV experiment conducted on a round jet, shows that the resolution of the shear layer at the jet exit can be considerably improved and an increase of about 25% in the vorticity peak is attained when the adaptive approach is applied. On the other hand, the peak vorticity description in the core of vortex rings is only slightly improved with

  2. Development of a coupled tendon-driven 3D multi-joint manipulator. Investigation of tension transfer efficiency, optimal reel arrangement and tip positioning accuracy

    International Nuclear Information System (INIS)

    Horigome, Atsushi; Yamada, Hiroya; Hirose, Shigeo; Sen, Shin; Endo, Gen

    2017-01-01

    Long-reach robotic manipulators are expected to be used in the space where humans cannot work such as nuclear power plant disaster areas. We suggested a coupled tendon-driven articulated manipulator '3D CT-Arm' and developed a preliminary prototype 'Mini 3D CT-Arm' whose arm had 2.4 m length and 0.3 m width. In order to consider developing '3D CT-Arm' deeply, we discussed tension transfer efficiency of a tendon through pulleys, the arrangement of the maximum number of reels in a limited space and the tip positioning accuracy. Through many transfer efficiency experiments, we conclude that tension transfer efficiency of '3D CT-Arm' can reach over 88% in the worst case. We investigated non-interfering reels' arrangement in the base by full search in cases of up to 10 reels. In all simulations, V-shaped or W-shaped arrangement can support the most reels in a limited space. Therefore, we conclude this is the most optimal reels' arrangement. Finally, we carried out the positioning accuracy experiment with 'Mini 3D CT-Arm' via motion capture system. Although the tip position had a 2 to 41 mm error between the desired value and the measured value by potentiometer, a 29 to 95 mm error between the desired value and the measured value was measured by motion capture system. (author)

  3. 16 CFR 1115.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SUBSTANTIAL PRODUCT HAZARD REPORTS General Interpretation § 1115.3 Definitions. In addition to the definitions given... Sunshine Act, 16 CFR part 1012. (c) Noncompliance means the failure of a consumer product to comply with an...

  4. Particle control in the DIII-D advanced divertor

    International Nuclear Information System (INIS)

    Schaffer, M.J.; Lippmann, S.I.; Mahdavi, M.A.; Petrie, T.W.; Stambaugh, R.D.; Hogan, J.; Klepper, C.C.; Mioduszewski, P.; Owen, L.; Hill, D.N.; Rensink, M.; Buchenauer, D.

    1991-11-01

    A new, electrically biasable, semi-closed divertor was installed and operated in the D3-D lower outside divertor location. The semi-closed divertor has yielded static gas pressure buildups in the pumping plenum in excess of 10 mtorr. (The planned cryogenic pumping is not yet installed). Electrical bias controls the distribution of particle recycle between the inner and outer divertors by rvec E x rvec B drifts. Depending on sign, bias increases or decreases the plenum gas pressure. Bias greatly reduce the sensitivity of plenum pressure to separatrix position. In particular, rvec E x rvec B drifts in the D3-D geometry can direct plasma across a divertor target and then optimally into the pumping aperture. Bias, even without active pumping, has also demonstrated a limited control of ELMing H-mode plasma density. 5 refs., 8 figs

  5. RELAP5-3D Developmental Assessment. Comparison of Version 4.3.4i on Linux and Windows

    International Nuclear Information System (INIS)

    Bayless, Paul David

    2015-01-01

    Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code, version 4.3i, compiled on Linux and Windows platforms. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions differ between the Linux and Windows versions.

  6. Fiducial-based fusion of 3D dental models with magnetic resonance imaging.

    Science.gov (United States)

    Abdi, Amir H; Hannam, Alan G; Fels, Sidney

    2018-04-16

    Magnetic resonance imaging (MRI) is widely used in study of maxillofacial structures. While MRI is the modality of choice for soft tissues, it fails to capture hard tissues such as bone and teeth. Virtual dental models, acquired by optical 3D scanners, are becoming more accessible for dental practice and are starting to replace the conventional dental impressions. The goal of this research is to fuse the high-resolution 3D dental models with MRI to enhance the value of imaging for applications where detailed analysis of maxillofacial structures are needed such as patient examination, surgical planning, and modeling. A subject-specific dental attachment was digitally designed and 3D printed based on the subject's face width and dental anatomy. The attachment contained 19 semi-ellipsoidal concavities in predetermined positions where oil-based ellipsoidal fiducial markers were later placed. The MRI was acquired while the subject bit on the dental attachment. The spatial position of the center of mass of each fiducial in the resultant MR Image was calculated by averaging its voxels' spatial coordinates. The rigid transformation to fuse dental models to MRI was calculated based on the least squares mapping of corresponding fiducials and solved via singular-value decomposition. The target registration error (TRE) of the proposed fusion process, calculated in a leave-one-fiducial-out fashion, was estimated at 0.49 mm. The results suggest that 6-9 fiducials suffice to achieve a TRE of equal to half the MRI voxel size. Ellipsoidal oil-based fiducials produce distinguishable intensities in MRI and can be used as registration fiducials. The achieved accuracy of the proposed approach is sufficient to leverage the merged 3D dental models with the MRI data for a finer analysis of the maxillofacial structures where complete geometry models are needed.

  7. Two Eyes, 3D: Stereoscopic Design Principles

    Science.gov (United States)

    Price, Aaron; Subbarao, M.; Wyatt, R.

    2013-01-01

    Two Eyes, 3D is a NSF-funded research project about how people perceive highly spatial objects when shown with 2D or stereoscopic ("3D") representations. As part of the project, we produced a short film about SN 2011fe. The high definition film has been rendered in both 2D and stereoscopic formats. It was developed according to a set of stereoscopic design principles we derived from the literature and past experience producing and studying stereoscopic films. Study participants take a pre- and post-test that involves a spatial cognition assessment and scientific knowledge questions about Type-1a supernovae. For the evaluation, participants use iPads in order to record spatial manipulation of the device and look for elements of embodied cognition. We will present early results and also describe the stereoscopic design principles and the rationale behind them. All of our content and software is available under open source licenses. More information is at www.twoeyes3d.org.

  8. Reliability of a semi-automated 3D-CT measuring method for tunnel diameters after anterior cruciate ligament reconstruction: A comparison between soft-tissue single-bundle allograft vs. autograft.

    Science.gov (United States)

    Robbrecht, Cedric; Claes, Steven; Cromheecke, Michiel; Mahieu, Peter; Kakavelakis, Kyriakos; Victor, Jan; Bellemans, Johan; Verdonk, Peter

    2014-10-01

    Post-operative widening of tibial and/or femoral bone tunnels is a common observation after ACL reconstruction, especially with soft-tissue grafts. There are no studies comparing tunnel widening in hamstring autografts versus tibialis anterior allografts. The goal of this study was to observe the difference in tunnel widening after the use of allograft vs. autograft for ACL reconstruction, by measuring it with a novel 3-D computed tomography based method. Thirty-five ACL-deficient subjects were included, underwent anatomic single-bundle ACL reconstruction and were evaluated at one year after surgery with the use of 3-D CT imaging. Three independent observers semi-automatically delineated femoral and tibial tunnel outlines, after which a best-fit cylinder was derived and the tunnel diameter was determined. Finally, intra- and inter-observer reliability of this novel measurement protocol was defined. In femoral tunnels, the intra-observer ICC was 0.973 (95% CI: 0.922-0.991) and the inter-observer ICC was 0.992 (95% CI: 0.982-0.996). In tibial tunnels, the intra-observer ICC was 0.955 (95% CI: 0.875-0.985). The combined inter-observer ICC was 0.970 (95% CI: 0.987-0.917). Tunnel widening was significantly higher in allografts compared to autografts, in the tibial tunnels (p=0.013) as well as in the femoral tunnels (p=0.007). To our knowledge, this novel, semi-automated 3D-computed tomography image processing method has shown to yield highly reproducible results for the measurement of bone tunnel diameter and area. This series showed a significantly higher amount of tunnel widening observed in the allograft group at one-year follow-up. Level II, Prospective comparative study. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The development of a pilot industrial irradiation facility; Realisation d'une station d'irradiation {gamma} a caractere 'semi-industriel'

    Energy Technology Data Exchange (ETDEWEB)

    Balestic, F; Leveque, P; Prevost, C; Comte, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Saclay, utilisee pour le stockage des barres d'uranium apres leur defournement, a ete specialement amenagee pour permettre des irradiations sur des quantites semi-industrielles de produits chimiques et alimentaires. Des calculs de flux {gamma} ont montre qu'il etait possible de realiser des sources intenses et d'irradier de grands volumes avec des arrangements particuliers de barres dans la casemate. L'installation comporte ainsi deux parties ou different la repartition des barres et les dispositifs d'irradiation. Dans une premiere chambre betonnee et climatisee, 9 rangees verticales de barres d'uranium et de canaux a irradiation alternent avec un ecartement minimum de fa n a constituer un assemblage compact. Le diametre des canaux varie de 10 a 20 cm et la hauteur de chargement utile, 70 cm, correspond a la zone sensiblement uniforme du rayonnement. Dans une deuxieme chambre maintenue a -7 deg. C, des balancelles (h: 70 cm, Q: 35 cm) guidees par un monorail circulent autour d'une seule rangee de 20 barres. La carte des flux y a l'interieur de la casemate a ete etablie par une methode de calcul deja utilisee pour les barres de la pile EL2 a Saclay. Le champ du rayonnement varie dans le temps principalement au cours des premiers mois apres le defournement et suivant le motif geo etrique adopte pour les barres. Les intensites d onisation theoriques sont comprises entre dix mille et plusieurs millions de roentgens par heure. Ces valeurs sont comparees aux resultats obtenus avec les dosimetres chimiques au sulfate ferreux et a l'acide oxalique. En outre, des verreseurs etalonnes avec des sources de cobalt permettent un controle rapide de la dose delivree aux balancelles du convoyeur durant leur parcours dans la chambre froide. La casemate de desactivation de EL3 constitue de par sa capacite de traitement la premiere realisation en France d'une station d'irradiation {gamma} a caractere semi-industriel effectuee avec le concours des services du Commissariat a l

  10. Silicon microstrip detectors in 3D technology for the sLHC

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany)], E-mail: ulrich.parzefall@physik.uni-freiburg.de; Dalla Betta, Gian-Franco [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Kuehn, Susanne; Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris; Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Zoboli, Andrea [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2009-08-01

    The projected luminosity upgrade of the large hadron collider (LHC), the sLHC, will constitute a challenging radiation environment for tracking detectors. Massive improvements in radiation hardness are required with respect to the LHC. In the layout for the new ATLAS tracker, silicon strip detectors (SSDs) with short strips cover the region from 28 to 60 cm distance to the beam. These SSDs will be exposed to fluences up to 10{sup 15}N{sub eq}/cm{sup 2}, hence radiation resistance is the major concern. It is advantageous to fuse the superior radiation hardness of the 3D design originally conceived for pixel-style applications with the benefits of the well-known planar technology for strip detectors. This is achieved by ganging rows of 3D columns together to form strips. Several prototype sLHC detector modules using 3D SSD with short strips, processed on p-type silicon, and LHC-speed front-end electronics from the present ATLAS semi-conductor tracker (SCT) were built. The modules were tested before and after irradiation to fluences of 10{sup 15}N{sub eq}/cm{sup 2}. The tests were performed with three systems: a highly focused IR-laser with 5{mu}m spot size to make position-resolved scans of the charge collection efficiency (CCE), a Sr{sup 90}{beta}-source set-up to measure the signal levels for a minimum ionizing particles (MIPs), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of the performance of these 3D modules, and draws conclusions about options for using 3D strip sensors as tracking detectors at the sLHC.

  11. Silicon microstrip detectors in 3D technology for the sLHC

    International Nuclear Information System (INIS)

    Parzefall, Ulrich; Dalla Betta, Gian-Franco; Eckert, Simon; Eklund, Lars; Fleta, Celeste; Jakobs, Karl; Kuehn, Susanne; Pahn, Gregor; Parkes, Chris; Pennicard, David; Ronchin, Sabina; Zoboli, Andrea; Zorzi, Nicola

    2009-01-01

    The projected luminosity upgrade of the large hadron collider (LHC), the sLHC, will constitute a challenging radiation environment for tracking detectors. Massive improvements in radiation hardness are required with respect to the LHC. In the layout for the new ATLAS tracker, silicon strip detectors (SSDs) with short strips cover the region from 28 to 60 cm distance to the beam. These SSDs will be exposed to fluences up to 10 15 N eq /cm 2 , hence radiation resistance is the major concern. It is advantageous to fuse the superior radiation hardness of the 3D design originally conceived for pixel-style applications with the benefits of the well-known planar technology for strip detectors. This is achieved by ganging rows of 3D columns together to form strips. Several prototype sLHC detector modules using 3D SSD with short strips, processed on p-type silicon, and LHC-speed front-end electronics from the present ATLAS semi-conductor tracker (SCT) were built. The modules were tested before and after irradiation to fluences of 10 15 N eq /cm 2 . The tests were performed with three systems: a highly focused IR-laser with 5μm spot size to make position-resolved scans of the charge collection efficiency (CCE), a Sr 90 β-source set-up to measure the signal levels for a minimum ionizing particles (MIPs), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of the performance of these 3D modules, and draws conclusions about options for using 3D strip sensors as tracking detectors at the sLHC.

  12. Low voltage operation of electro-absorption modulator promising for high-definition 3D imaging application using a three step asymmetric coupled quantum well structure

    International Nuclear Information System (INIS)

    Na, Byung Hoon; Ju, Gun Wu; Cho, Yong Chul; Lee, Yong Tak; Choi, Hee Ju; Jeon, Jin Myeong; Lee, Soo Kyung; Park, Yong Hwa; Park, Chang Young

    2015-01-01

    In this paper, we propose a transmission type electro-absorption modulator (EAM) operating at 850 nm having low operating voltage and high absorption change with low insertion loss using a novel three step asymmetric coupled quantum well (3 ACQW) structure which can be used as an optical image shutter for high-definition (HD) three dimensional (3D) imaging. Theoretical calculations show that the exciton red shift of 3 ACQW structure is more than two times larger than that of rectangular quantum well (RQW) structure while maintaining high absorption change. The EAM having coupled cavities with 3 ACQW structure shows a wide spectral bandwidth and high amplitude modulation at a bias voltage of only -8V, which is 41% lower in operating voltage than that of RQW, making the proposed EAM highly attractive as an optical image shutter for HD 3D imaging applications

  13. Designing stereoscopic information visualization for 3D-TV: What can we can learn from S3D gaming?

    Science.gov (United States)

    Schild, Jonas; Masuch, Maic

    2012-03-01

    This paper explores graphical design and spatial alignment of visual information and graphical elements into stereoscopically filmed content, e.g. captions, subtitles, and especially more complex elements in 3D-TV productions. The method used is a descriptive analysis of existing computer- and video games that have been adapted for stereoscopic display using semi-automatic rendering techniques (e.g. Nvidia 3D Vision) or games which have been specifically designed for stereoscopic vision. Digital games often feature compelling visual interfaces that combine high usability with creative visual design. We explore selected examples of game interfaces in stereoscopic vision regarding their stereoscopic characteristics, how they draw attention, how we judge effect and comfort and where the interfaces fail. As a result, we propose a list of five aspects which should be considered when designing stereoscopic visual information: explicit information, implicit information, spatial reference, drawing attention, and vertical alignment. We discuss possible consequences, opportunities and challenges for integrating visual information elements into 3D-TV content. This work shall further help to improve current editing systems and identifies a need for future editing systems for 3DTV, e.g., live editing and real-time alignment of visual information into 3D footage.

  14. 12 CFR 3.2 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... Authority and Definitions § 3.2 Definitions. For the purposes of this part: (a) Adjusted total assets means the average total assets figure required to be computed for and stated in a bank's most recent quarterly Consolidated Report of Condition and Income (Call Report) minus end-of-quarter intangible assets...

  15. Impact of 4D image quality on the accuracy of target definition

    International Nuclear Information System (INIS)

    Nielson, Tim B.; Hansen, Christian R.; Westberg, Jonas; Hansen, Olfred; Brink, Carsten

    2016-01-01

    Delineation accuracy of target shape and position depends on the image quality. This study investigates whether the image quality on standard 4D systems has an influence comparable to the overall delineation uncertainty. A moving lung target was imaged using a dynamic thorax phantom on three different 4D computed tomography (CT) systems and a 4D cone beam CT (CBCT) system using pre-defined clinical scanning protocols. Peak-to-peak motion and target volume were registered using rigid registration and automatic delineation, respectively. A spatial distribution of the imaging uncertainty was calculated as the distance deviation between the imaged target and the true target shape. The measured motions were smaller than actual motions. There were volume differences of the imaged target between respiration phases. Imaging uncertainties of >0.4 cm were measured in the motion direction which showed that there was a large distortion of the imaged target shape. Imaging uncertainties of standard 4D systems are of similar size as typical GTV–CTV expansions (0.5–1 cm) and contribute considerably to the target definition uncertainty. Optimising and validating 4D systems is recommended in order to obtain the most optimal imaged target shape.

  16. Impact of 4D image quality on the accuracy of target definition.

    Science.gov (United States)

    Nielsen, Tine Bjørn; Hansen, Christian Rønn; Westberg, Jonas; Hansen, Olfred; Brink, Carsten

    2016-03-01

    Delineation accuracy of target shape and position depends on the image quality. This study investigates whether the image quality on standard 4D systems has an influence comparable to the overall delineation uncertainty. A moving lung target was imaged using a dynamic thorax phantom on three different 4D computed tomography (CT) systems and a 4D cone beam CT (CBCT) system using pre-defined clinical scanning protocols. Peak-to-peak motion and target volume were registered using rigid registration and automatic delineation, respectively. A spatial distribution of the imaging uncertainty was calculated as the distance deviation between the imaged target and the true target shape. The measured motions were smaller than actual motions. There were volume differences of the imaged target between respiration phases. Imaging uncertainties of >0.4 cm were measured in the motion direction which showed that there was a large distortion of the imaged target shape. Imaging uncertainties of standard 4D systems are of similar size as typical GTV-CTV expansions (0.5-1 cm) and contribute considerably to the target definition uncertainty. Optimising and validating 4D systems is recommended in order to obtain the most optimal imaged target shape.

  17. Selection of best entrepreneurship practices in relation to the emerging 3D internet

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth; Flåten, Bjørn-Tore

    This report focuses on entrepreneurship in relation to the 3D internet in general (aka virtual worlds, virtual environments, etc.) and the selection of best practices specifically. In preparing this report, we focused primarily on the Nordic countries and the USA and on empirically-based research...... articles. We faced three major challenges when going through the scientific research literature: 1) the lack of and fragmentation of knowledge due to the relative infancy of the 3D internet field and its interdisciplinary nature across many research fields, 2) the fluid definitions of terms regarding the 3...... of entrepreneurship in relation to the emergence of virtual worlds / 3D internet, 3) the definitions and review of literature on entrepreneurship, 4) selection of best entrepreneurial practices, and 5) discussion and preliminary conclusions....

  18. A facile route for 3D aerogels from nanostructured 1D and 2D materials

    Science.gov (United States)

    Jung, Sung Mi; Jung, Hyun Young; Dresselhaus, Mildred S.; Jung, Yung Joon; Kong, Jing

    2012-01-01

    Aerogels have numerous applications due to their high surface area and low densities. However, creating aerogels from a large variety of materials has remained an outstanding challenge. Here, we report a new methodology to enable aerogel production with a wide range of materials. The method is based on the assembly of anisotropic nano-objects (one-dimensional (1D) nanotubes, nanowires, or two-dimensional (2D) nanosheets) into a cross-linking network from their colloidal suspensions at the transition from the semi-dilute to the isotropic concentrated regime. The resultant aerogels have highly porous and ultrafine three-dimensional (3D) networks consisting of 1D (Ag, Si, MnO2, single-walled carbon nanotubes (SWNTs)) and 2D materials (MoS2, graphene, h-BN) with high surface areas, low densities, and high electrical conductivities. This method opens up a facile route for aerogel production with a wide variety of materials and tremendous opportunities for bio-scaffold, energy storage, thermoelectric, catalysis, and hydrogen storage applications. PMID:23152940

  19. 48 CFR 970.0371-3 - Definition.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Definition. 970.0371-3... Interest 970.0371-3 Definition. Employees, as used in this section, are defined to mean individuals employed by the contractor, both full and part-time, who are assigned to work under a DOE management and...

  20. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    Energy Technology Data Exchange (ETDEWEB)

    Orlić, Ivica; Mekterović, Darko [Department of Physics, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka (Croatia); Mekterović, Igor [Faculty of Electrical Engineering and Computing, University of Zagreb (Croatia); Ivošević, Tatjana [Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka (Croatia)

    2015-11-15

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster–Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By “running” a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  1. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    International Nuclear Information System (INIS)

    Orlić, Ivica; Mekterović, Darko; Mekterović, Igor; Ivošević, Tatjana

    2015-01-01

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster–Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By “running” a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  2. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    Science.gov (United States)

    Orlić, Ivica; Mekterović, Darko; Mekterović, Igor; Ivošević, Tatjana

    2015-11-01

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster-Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By "running" a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  3. 3D composite image, 3D MRI, 3D SPECT, hydrocephalus

    International Nuclear Information System (INIS)

    Mito, T.; Shibata, I.; Sugo, N.; Takano, M.; Takahashi, H.

    2002-01-01

    2 by the use of a program prepared by combining the advantage of a surface rendering method with that of a volume rendering method by means of the general-purpose visualization software AVS-MV (Application Visualization System Medical Viewer). The AVS-MV permits production of semitransparent images as well, so that metabolic and physiological functions in internal tissues with the same threshold value can be seen through external tissues. The voxel and threshold distribution curve was plotted and analyzed by this software. The distribution of voxel in normal individuals shows such a bimodal curve that RI count presents a trough at a threshold value of 40% and a crest at 70%. In hydrocephalus, on the other hand, the 40% region showed an increase and 70% region showed a decrease . After shunt operation for hydrocephalus, with improvement in symptoms, the 40% region decreased and 70% region increased, so that a normal pattern was approached. This composite 3D MRI and SPECT imaging technique made it possible not only to establish an intracranial position in SPECT, but also to assess the profile of cerebral circulation around the cerebral venuicles. Analysis of these 3D composite images permits quantitative expression of brain volume in SPECT and extensive elucidation of the cerebral circulation profile in morphological detail. This analysis is, therefore, considered to contribute largely to the development of functional images

  4. The value of positive Oct3/4 and D2-40 immunohistochemical expression in prediction of germ cell neoplasia in prepubertal boys with cryptorchidism

    DEFF Research Database (Denmark)

    Clasen-Linde, Erik; Kvist, Kolja; Cortes, Dina

    2016-01-01

    , where most orchiopexies are performed. The aim of the study was to evaluate the ability of Oct3/4 and D2-40 immunohistochemical markers to detect ITGCN in boys older than 2 years with cryptorchidism. MATERIALS AND METHODS: Histological sections from 309 testicular biopsies from 234 boys aged 1 month...... to 14 years, 6 months operated on for cryptorchidism were incubated with primary antibodies including anti-placental-like alkaline phosphatase, anti-Oct3/4, anti-C-kit and anti-D2-40 receptor. RESULTS: One 3-year, 8-month-old boy with 45X/46XY disorder of sexual development had ITGCN and all positive...... markers. Besides this case, none of the 192 testes except one from boys older than 2 years had any Oct3/4- or D2-40-positive germ cells identified. The germ cells of the right testis from a 3-year, 7-month-old boy had weak Oct3/4 expression but were D2-40 negative. The prevalences of Oct3/4- and D2...

  5. The First Static and Dynamic Analysis of 3-D Printed Sintered Ceramics for Body Armor Applications

    Science.gov (United States)

    2016-09-01

    hardness , and fracture strength) and semi-infinite penetration performance of 3-D printed sintered alumina. These results are compared with traditionally...parameters (including density, hardness , and fracture strength), semi-infinite penetration performance, and the fracture profile following impact of 3...of advanced ceramics differs mostly in terms of the initial green part formation when compared with a traditional manufacturing process. The

  6. Determination of vitamins D2, D3, K1 and K3 and some hydroxy metabolites of vitamin D3 in plasma using a continuous clean-up-preconcentration procedure coupled on-line with liquid chromatography-UV detection.

    Science.gov (United States)

    Ortiz Boyer, F; Fernández Romero, J M; Luque de Castro, M D; Quesada, J M

    1999-03-01

    A semi-automatic procedure for the continuous clean-up and concentration of several fat-soluble vitamins prior to their separation by HPLC and UV detection is reported. The procedure is based on the use of a minicolumn packed with aminopropylsilica as sorbent located prior to the chromatographic detection system. The overall process was developed and applied to the main liposoluble vitamins (A, D2, D3, E, K1, K3) and several hydroxy metabolites of vitamin D3 [25-(OH)-D3,24,25-(OH)2-D3 and 1,25-(OH)2-D3]. All the analytes were monitored at a compromise wavelength of 270 nm. Calibration graphs were constructed between 0.01 and 100 ng ml-1 for vitamin D2 and D3 and their hydroxy metabolites, between 0.1 and 100 ng ml-1 for vitamin A, K1 and K3 and between 1 and 100 ng ml-1 for vitamin E, with excellent regression coefficients (> or = 0.9901) in all cases. The precision was established at two concentration levels with acceptable RSDs in all instances (between 3.6 and 8.7%). The method was appropriate for the determination of vitamin D2, D3, K1 and K3 and the 24,25-dihydroxy and 25-hydroxy metabolites of vitamin D3 in human plasma. The method was applied to plasma samples spiked with the target analytes and the recoveries ranged between 78 and 109%.

  7. Inclusive and semi-inclusive analysis from polarised deep-inelastic muon scattering

    International Nuclear Information System (INIS)

    Kageya, T.

    1999-01-01

    We present new results for the spin-dependent structure function on the proton and for the polarised quark distributions in the nucleon from semi-inclusive spin asymmetries. With the inclusive asymmetry from deep inelastic scattering of polarised muons on polarised protons, it is found that the Ellis-Jaffe sum rule is violated. Using our results for Γ d 1 , the Bjorken sum rule is confirmed with an accuracy of about 15%. From semi-inclusive spin asymmetries and SMC inclusive spin asymmetries, we determine the polarised quark distributions of valence u and d quarks to be positive and negative, respectively, while the non-strange sea distribution to be consistent with zero

  8. A novel alternative method for 3D visualisation in Parasitology: the construction of a 3D model of a parasite from 2D illustrations.

    Science.gov (United States)

    Teo, B G; Sarinder, K K S; Lim, L H S

    2010-08-01

    Three-dimensional (3D) models of the marginal hooks, dorsal and ventral anchors, bars and haptoral reservoirs of a parasite, Sundatrema langkawiense Lim & Gibson, 2009 (Monogenea) were developed using the polygonal modelling method in Autodesk 3ds Max (Version 9) based on two-dimensional (2D) illustrations. Maxscripts were written to rotate the modelled 3D structures. Appropriately orientated 3D haptoral hard-parts were then selected and positioned within the transparent 3D outline of the haptor and grouped together to form a complete 3D haptoral entity. This technique is an inexpensive tool for constructing 3D models from 2D illustrations for 3D visualisation of the spatial relationships between the different structural parts within organisms.

  9. Definition of a safe zone for antegrade lag screw fixation of fracture of posterior column of the acetabulum by 3D technology.

    Science.gov (United States)

    Feng, Xiaoreng; Zhang, Sheng; Luo, Qiang; Fang, Jintao; Lin, Chaowen; Leung, Frankie; Chen, Bin

    2016-03-01

    The objective of this study was to define a safe zone for antegrade lag screw fixation of fracture of posterior column of the acetabulum using a novel 3D technology. Pelvic CT data of 59 human subjects were obtained to reconstruct three-dimensional (3D) models. The transparency of 3D models was then downgraded along the axial perspective (the view perpendicular to the cross section of the posterior column axis) to find the largest translucent area. The outline of the largest translucent area was drawn on the iliac fossa. The line segments of OA, AB, OC, CD, the angles of OAB and OCD that delineate the safe zone (ABDC) were precisely measured. The resultant line segments OA, AB, OC, CD, and angles OAB and OCD were 28.46mm(13.15-44.97mm), 45.89mm (34.21-62.85mm), 36.34mm (18.68-55.56mm), 53.08mm (38.72-75.79mm), 37.44° (24.32-54.96°) and 55.78° (43.97-79.35°) respectively. This study demonstrates that computer-assisted 3D modelling techniques can aid in the precise definition of the safe zone for antegrade insertion of posterior column lag screws. A full-length lag screw can be inserted into the zone (ABDC), permitting a larger operational error. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Semi-Markov processes

    CERN Document Server

    Grabski

    2014-01-01

    Semi-Markov Processes: Applications in System Reliability and Maintenance is a modern view of discrete state space and continuous time semi-Markov processes and their applications in reliability and maintenance. The book explains how to construct semi-Markov models and discusses the different reliability parameters and characteristics that can be obtained from those models. The book is a useful resource for mathematicians, engineering practitioners, and PhD and MSc students who want to understand the basic concepts and results of semi-Markov process theory. Clearly defines the properties and

  11. Analysis of effect of 1α-hydroxyvitamin D3 on benign paroxysmal positional vertigo and risk factors.

    Science.gov (United States)

    Gu, Xiang; Dong, Feilin; Gu, Jianhua

    2018-03-01

    The purpose of this study was to investigate the curative effect of 1α-hydroxyvitamin D3 on the benign paroxysmal positional vertigo (BPPV). Fifty BPPV patients diagnosed in the ENT Department of Anzhen Hospital from October 2015 to December 2016 were randomly selected as the treatment group, and treated with 0.25 µg 1α-hydroxyvitamin D3 once per day, in addition to the routine diagnosis and treatment. Moreover, 50 BPPV patients in the same period were selected as the control group, and received the routine diagnosis and treatment. The detection results of bone mineral density (BMD) t-value, vitamin D3 and bone metabolic markers before and after treatment were compared, and statistical analysis was performed on the results. There were no differences in the general data between treatment group and control group. There were no statistically significant differences in the BMD and age distribution of males and females between treatment group and control group (P>0.05). The BMD of male BPPV patients in each age group in the treatment group was significantly increased after treatment, and the difference was statistically significant (P0.05). The BMD of female BPPV patients in each age group in treatment group was increased after treatment, and the difference was statistically significant (P0.05). The average BMD of female BPPV patients in each age group was significantly lower than that of male patients, and the difference was statistically significant (Pdiabetes mellitus, age (>50 years), 25-hydroxyvitamin D3 and osteopenia/osteoporosis, as the independent variables, and the results suggested that the level of 25-hydroxyvitamin D3 and osteopenia/osteoporosis are the clinical features of whether the BPPV treatment is effective (P<0.05). The results showed that the treatment of BPPV with 1α-hydroxyvitamin D3 can effectively improve the symptoms of patients, and the level of vitamin D3 and the occurrence of osteopenia/osteoporosis are the clinical indexes of whether

  12. A Unified 3D Mesh Segmentation Framework Based on Markov Random Field

    OpenAIRE

    Z.F. Shi; L.Y. Lu; D. Le; X.M. Niu

    2012-01-01

    3D Mesh segmentation has become an important research field in computer graphics during the past decades. Many geometry based and semantic oriented approaches for 3D mesh segmentation has been presented. In this paper, we present a definition of mesh segmentation according to labeling problem. Inspired by the Markov Random Field (MRF) based image segmentation, we propose a new framework of 3D mesh segmentation based on MRF and use graph cuts to solve it. Any features of 3D mesh can be integra...

  13. Stability Analysis Of 3-d Conventional Pallet Rack Structures With Semi-rigid Connections

    Directory of Open Access Journals (Sweden)

    Kamal M. Bajoria

    2009-12-01

    Full Text Available This paper describe the three dimensional finite element modeling and buckling analysis of conventional pallet racking system with semi rigid connection. In this study three dimensional models of conventional pallet racking system were prepared using the finiteelement program ANSYS and finite element analysis carried out on conventional pallet racks with the 18 types of column sections developed along with semi-rigid connections. A parametric study was carried out to compare the effective length approach and the finiteelement method for accuracy and appropriateness for cold-formed steel frame design. Numerous frame elastic buckling analyses were carried out to evaluate the alignment chart and the AISI torsional-flexural buckling provisions. The parameters that influence the valueof Kx for column flexural buckling were examined in this study. The alignment chart and the AISI torsional-flexural buckling provisions, used to obtain the effective lengths and elastic buckling load of members were also evaluated. Results showed that the elastic buckling load obtained from the AISI torsional-flexural buckling provisions is generally conservative compared to the results obtained from performing frame elastic buckling analysis. Results also showed that, the effective length approach is more conservative than the finite element approach.

  14. Towards Precise Metadata-set for Discovering 3D Geospatial Models in Geo-portals

    Science.gov (United States)

    Zamyadi, A.; Pouliot, J.; Bédard, Y.

    2013-09-01

    Accessing 3D geospatial models, eventually at no cost and for unrestricted use, is certainly an important issue as they become popular among participatory communities, consultants, and officials. Various geo-portals, mainly established for 2D resources, have tried to provide access to existing 3D resources such as digital elevation model, LIDAR or classic topographic data. Describing the content of data, metadata is a key component of data discovery in geo-portals. An inventory of seven online geo-portals and commercial catalogues shows that the metadata referring to 3D information is very different from one geo-portal to another as well as for similar 3D resources in the same geo-portal. The inventory considered 971 data resources affiliated with elevation. 51% of them were from three geo-portals running at Canadian federal and municipal levels whose metadata resources did not consider 3D model by any definition. Regarding the remaining 49% which refer to 3D models, different definition of terms and metadata were found, resulting in confusion and misinterpretation. The overall assessment of these geo-portals clearly shows that the provided metadata do not integrate specific and common information about 3D geospatial models. Accordingly, the main objective of this research is to improve 3D geospatial model discovery in geo-portals by adding a specific metadata-set. Based on the knowledge and current practices on 3D modeling, and 3D data acquisition and management, a set of metadata is proposed to increase its suitability for 3D geospatial models. This metadata-set enables the definition of genuine classes, fields, and code-lists for a 3D metadata profile. The main structure of the proposal contains 21 metadata classes. These classes are classified in three packages as General and Complementary on contextual and structural information, and Availability on the transition from storage to delivery format. The proposed metadata set is compared with Canadian Geospatial

  15. Nova abordagem metodológica para locação, modelagem 3D e monitoramento de barragens subterrâneas no semiárido brasileiro

    OpenAIRE

    Lima, Alexandre de Oliveira

    2013-01-01

    Apesar do número significativo de barragens construídas nos últimos anos no Brasil e mesmo em outros países, são poucos os estudos técnicos que dão suporte a este crescimento. Com o objetivo de propor uma nova abordagem metodológica para o processo de locação e monitoramento de barragens subterrâneas, em condições de clima semiárido, foram realizados estudos em duas sub-bacias hidrográficas (do rio das Cobras e Pau Lavrado) ambas situadas no semiárido do Estado do Rio Grande. Nesta nova abord...

  16. 14 CFR 137.3 - Definition of terms.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Definition of terms. 137.3 Section 137.3... General § 137.3 Definition of terms. For the purposes of this part— Agricultural aircraft operation means... man or other animals, which the Secretary of Agriculture shall declare to be a pest, and (2) any...

  17. TRANSITION FROM 2D TO 3D WITH GEOGEBRA

    Directory of Open Access Journals (Sweden)

    MARIA MIHAILOVA

    2014-12-01

    Full Text Available This article presents the definition of projection plane, its importance for the geometry constructions used in civil engineering and comparative analysis of three opportunities for creating a three dimensional basis, used in drawing such a plane. First method consists of transforming affine and orthonormal coordinates and its application in GeoGebra is presented. Second method, using combination of spherical and polar coordinates in space, is introduced. The third suggested method is an application of descriptive geometry for transforming 2D to 3D and a new method of forming a plane of projection, which will be used later in the reviewed example below. The example shows how GeoGebra software can be used in technical drawing used in civil engineering.

  18. Robust Solvers for Symmetric Positive Definite Operators and Weighted Poincaré Inequalities

    KAUST Repository

    Efendiev, Yalchin; Galvis, Juan; Lazarov, Raytcho; Willems, Joerg

    2012-01-01

    An abstract setting for robustly preconditioning symmetric positive definite (SPD) operators is presented. The term "robust" refers to the property of the condition numbers of the preconditioned systems being independent of mesh parameters

  19. Activated sludge models ASM1, ASM2, ASM2d and ASM3

    DEFF Research Database (Denmark)

    Henze, Mogens; Gujer, W.; Mino, T.

    This book has been produced to give a total overview of the Activated Sludge Model (ASM) family at the start of 2000 and to give the reader easy access to the different models in their original versions. It thus presents ASM1, ASM2, ASM2d and ASM3 together for the first time.Modelling of activated...... sludge processes has become a common part of the design and operation of wastewater treatment plants. Today models are being used in design, control, teaching and research.ContentsASM3: Introduction, Comparison of ASM1 and ASM3, ASM3: Definition of compounds in the model, ASM3: Definition of processes...... in the Model, ASM3: Stoichiometry, ASM3: Kinetics, Limitations of ASM3, Aspects of application of ASM3, ASM3C: A Carbon based model, Conclusion ASM 2d: Introduction, Conceptual Approach, ASM 2d, Typical Wastewater Characteristics and Kinetic and Stoichiometric Constants, Limitations, Conclusion ASM 2...

  20. 16 CFR 240.3 - Definition of seller.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Definition of seller. 240.3 Section 240.3 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR ADVERTISING ALLOWANCES AND OTHER MERCHANDISING PAYMENTS AND SERVICES § 240.3 Definition of seller. Seller includes any...

  1. Tacit definitions of informal caregiving.

    Science.gov (United States)

    Wrubel, J; Richards, T A; Folkman, S; Acree, M C

    2001-01-01

    This study describes three tacit definitions of informal caregiving and explores the extent to which differences in these tacit definitions explain variation in caregivers' negative mood over time. There is a growing need to understand the sources of stress and gratification for informal caregivers. Tacit definitions of informal caregiving refer to caregivers' understanding of what caregiving entails. These definitions are tacit because they arise from caregivers' taken-for-granted understanding rather than formally articulated positions concerning caregiving. A random sample of 60 men, all of whom were caregiving partners of men with acquired immunodeficiency syndrome (AIDS), was drawn from a larger cohort of 253 participants in the University of California San Francisco (UCSF) Coping Project (1990-1997). The caregivers were assessed bimonthly for 2 years with procedures that included a semi-structured interview focusing on a recent stressful event involving caregiving, and quantitative measures of well-being. Interpretive phenomenological case studies of the narrative accounts of the 60 caregivers produced three tacit definitions of caregiving - engagement, conflict and distance. These three tacit definitions were distinguished by differences in learning about caregiving, involvement in health care decisions, caregiving activities and reported sources of stress. The three groups differed on measures of dyadic adjustment, depression, anger and anxiety. Better understanding of caregivers' tacit definitions can facilitate and enhance effective support and interventions for caregivers.

  2. 3D Printing of Highly Stretchable, Shape-Memory, and Self-Healing Elastomer toward Novel 4D Printing.

    Science.gov (United States)

    Kuang, Xiao; Chen, Kaijuan; Dunn, Conner K; Wu, Jiangtao; Li, Vincent C F; Qi, H Jerry

    2018-02-28

    The three-dimensional (3D) printing of flexible and stretchable materials with smart functions such as shape memory (SM) and self-healing (SH) is highly desirable for the development of future 4D printing technology for myriad applications, such as soft actuators, deployable smart medical devices, and flexible electronics. Here, we report a novel ink that can be used for the 3D printing of highly stretchable, SM, and SH elastomer via UV-light-assisted direct-ink-write printing. An ink containing urethane diacrylate and a linear semicrystalline polymer is developed for the 3D printing of a semi-interpenetrating polymer network elastomer that can be stretched by up to 600%. The 3D-printed complex structures show interesting functional properties, such as high strain SM and SM -assisted SH capability. We demonstrate that such a 3D-printed SM elastomer has the potential application for biomedical devices, such as vascular repair devices. This research paves a new way for the further development of novel 4D printing, soft robotics, and biomedical devices.

  3. Strange mass corrections to hyperonic semi-leptonic decays in statistical model

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyay, A.; Batra, M. [Thapar University, School of Physics and Material Science, Patiala (India)

    2013-12-15

    We study the spin distribution, weak decay coupling constant ratios for strange baryon octets with SU(3) breaking effects. Baryon is taken as an ensemble of quark-gluon Fock states in the sea with three valence quarks with definite spin, color and flavor quantum numbers. We apply the statistical model to calculate the probabilities of each Fock states, to analyze the impact of SU(3) breaking in the weak decays. The symmetry breaking effects are studied in terms of a parameter ''r '' whose best-fit value is obtained from the experimental data of semi-leptonic weak decay coupling constant ratios. We suggest the dominant contribution from H{sub 1}G{sub 8} (sea with spin one and color octet) where symmetry breaking corrections lead to the deviations in the value of the axial-vector matrix elements ratio F/D from experimental values by 17%. We conclude that symmetry breaking also significantly affects the polarization of quark in strange baryons. (orig.)

  4. Self-Sensing of Position-Related Loads in Continuous Carbon Fibers-Embedded 3D-Printed Polymer Structures Using Electrical Resistance Measurement.

    Science.gov (United States)

    Luan, Congcong; Yao, Xinhua; Shen, Hongyao; Fu, Jianzhong

    2018-03-27

    Condition monitoring in polymer composites and structures based on continuous carbon fibers show overwhelming advantages over other potentially competitive sensing technologies in long-gauge measurements due to their great electromechanical behavior and excellent reinforcement property. Although carbon fibers have been developed as strain- or stress-sensing agents in composite structures through electrical resistance measurements, the electromechanical behavior under flexural loads in terms of different loading positions still lacks adequate research, which is the most common situation in practical applications. This study establishes the relationship between the fractional change in electrical resistance of carbon fibers and the external loads at different loading positions along the fibers' longitudinal direction. An approach for real-time monitoring of flexural loads at different loading positions was presented simultaneously based on this relationship. The effectiveness and feasibility of the approach were verified by experiments on carbon fiber-embedded three-dimensional (3D) printed thermoplastic polymer beam. The error in using the provided approach to monitor the external loads at different loading positions was less than 1.28%. The study fully taps the potential of continuous carbon fibers as long-gauge sensory agents and reinforcement in the 3D-printed polymer structures.

  5. Self-Sensing of Position-Related Loads in Continuous Carbon Fibers-Embedded 3D-Printed Polymer Structures Using Electrical Resistance Measurement

    Directory of Open Access Journals (Sweden)

    Congcong Luan

    2018-03-01

    Full Text Available Condition monitoring in polymer composites and structures based on continuous carbon fibers show overwhelming advantages over other potentially competitive sensing technologies in long-gauge measurements due to their great electromechanical behavior and excellent reinforcement property. Although carbon fibers have been developed as strain- or stress-sensing agents in composite structures through electrical resistance measurements, the electromechanical behavior under flexural loads in terms of different loading positions still lacks adequate research, which is the most common situation in practical applications. This study establishes the relationship between the fractional change in electrical resistance of carbon fibers and the external loads at different loading positions along the fibers’ longitudinal direction. An approach for real-time monitoring of flexural loads at different loading positions was presented simultaneously based on this relationship. The effectiveness and feasibility of the approach were verified by experiments on carbon fiber-embedded three-dimensional (3D printed thermoplastic polymer beam. The error in using the provided approach to monitor the external loads at different loading positions was less than 1.28%. The study fully taps the potential of continuous carbon fibers as long-gauge sensory agents and reinforcement in the 3D-printed polymer structures.

  6. MBE growth of Topological Isolators based on strained semi-metallic HgCdTe layers

    Science.gov (United States)

    Grendysa, J.; Tomaka, G.; Sliz, P.; Becker, C. R.; Trzyna, M.; Wojnarowska-Nowak, R.; Bobko, E.; Sheregii, E. M.

    2017-12-01

    Particularities of Molecular Beam Epitaxial (MBE) technology for the growth of Topological Insulators (TI) based on the semi-metal Hg1-xCdx Te are presented. A series of strained layers grown on GaAs substrates with a composition close to the 3D Dirac point were studied. The composition of the layers was verified by means of the position of the E1 maximum in optical reflectivity in the visible region. The surface morphology was determined via atomic force and electron microscopy. Magneto-transport measurements show quantized Hall resistance curves and Shubnikov de Hass oscillations (up to 50 K). It has been demonstrated that a well-developed MBE technology enables one to grow strained Hg1-xCdx Te layers on GaAs/CdTe substrates with a well-defined composition near the 3D Dirac point and consequently allows one to produce a 3D topological Dirac semimetal - 3D analogy of graphene - for future applications.

  7. 3D-Printed masks as a new approach for immobilization in radiotherapy - a study of positioning accuracy.

    Science.gov (United States)

    Haefner, Matthias Felix; Giesel, Frederik Lars; Mattke, Matthias; Rath, Daniel; Wade, Moritz; Kuypers, Jacob; Preuss, Alan; Kauczor, Hans-Ulrich; Schenk, Jens-Peter; Debus, Juergen; Sterzing, Florian; Unterhinninghofen, Roland

    2018-01-19

    We developed a new approach to produce individual immobilization devices for the head based on MRI data and 3D printing technologies. The purpose of this study was to determine positioning accuracy with healthy volunteers. 3D MRI data of the head were acquired for 8 volunteers. In-house developed software processed the image data to generate a surface mesh model of the immobilization mask. After adding an interface for the couch, the fixation setup was materialized using a 3D printer with acrylonitrile butadiene styrene (ABS). Repeated MRI datasets (n=10) were acquired for all volunteers wearing their masks thus simulating a setup for multiple fractions. Using automatic image-to-image registration, displacements of the head were calculated relative to the first dataset (6 degrees of freedom). The production process has been described in detail. The absolute lateral (x), vertical (y) and longitudinal (z) translations ranged between -0.7 and 0.5 mm, -1.8 and 1.4 mm, and -1.6 and 2.4 mm, respectively. The absolute rotations for pitch (x), yaw (y) and roll (z) ranged between -0.9 and 0.8°, -0.5 and 1.1°, and -0.6 and 0.8°, respectively. The mean 3D displacement was 0.9 mm with a standard deviation (SD) of the systematic and random error of 0.2 mm and 0.5 mm, respectively. In conclusion, an almost entirely automated production process of 3D printed immobilization masks for the head derived from MRI data was established. A high level of setup accuracy was demonstrated in a volunteer cohort. Future research will have to focus on workflow optimization and clinical evaluation.

  8. Semi-strong split domination in graphs

    Directory of Open Access Journals (Sweden)

    Anwar Alwardi

    2014-06-01

    Full Text Available Given a graph $G = (V,E$, a dominating set $D subseteq V$ is called a semi-strong split dominating set of $G$ if $|V setminus D| geq 1$ and the maximum degree of the subgraph induced by $V setminus D$ is 1. The minimum cardinality of a semi-strong split dominating set (SSSDS of G is the semi-strong split domination number of G, denoted $gamma_{sss}(G$. In this work, we introduce the concept and prove several results regarding it.

  9. Focal points and the phase of the semi-classical propagator

    International Nuclear Information System (INIS)

    Levit, S.; Moehring, K.; Smilansky, U.; Dreyfus, T.

    1977-01-01

    The relation between the phase of the semi-classical propagator and the number of times the classical trajectory is reflected from a caustic is discussed. It is shown that the accepted prescription based on Morse's focal point theorem is valid only for a restricted class of problems (coordinate representation and a positive definite mass tensor). A more general method to evaluate the phase is derived. It applies to all problems of physical interest involving the most general representations (mixed coordinate and momentum) and complicated Hamiltonian functions. The result is of particular relevance for the classical S-matrix. (author)

  10. Activite locomotrice de souris isolees, de deux lignees consanguines, dans un environnement semi-naturel ou en cages d'elevage.

    Science.gov (United States)

    Le Pape, G; Lassalle, J M

    1979-10-01

    Des enregistrements continus d'activité locomotrice ont été effectués sur des souris mâles isolées des lignées Balb/c et C57bl/6, vivant en cages d'élevage ou en milieu semi- naturel. Les résultats montrent que les différences entre ces deux situations ne sont pas perçues de la même façon par les animaux des deux lign'ees: alors qu'en cages d'élevage les souris des deux lignées experiment la même quantité totale d'activaté, en milieu semi-naturel les souris Balb/c sont plus actives que les C57bl/6. En outre, l≐s différences observées entre les lignées pour la repartition de l'activité au cours du nycthèmere s'inversent lorsque l'on passe d'une situation à l'autre. L'étude de la variabilité fait aparaître une dispersion plus grande des performances dans la lignée C57bl/6 en cages d'élevage, alors qu'en milieu semi-naturel la dispersion est plus chez Bal/c. Copyright © 1979. Published by Elsevier B.V.

  11. 3D vision system for intelligent milking robot automation

    Science.gov (United States)

    Akhloufi, M. A.

    2013-12-01

    In a milking robot, the correct localization and positioning of milking teat cups is of very high importance. The milking robots technology has not changed since a decade and is based primarily on laser profiles for teats approximate positions estimation. This technology has reached its limit and does not allow optimal positioning of the milking cups. Also, in the presence of occlusions, the milking robot fails to milk the cow. These problems, have economic consequences for producers and animal health (e.g. development of mastitis). To overcome the limitations of current robots, we have developed a new system based on 3D vision, capable of efficiently positioning the milking cups. A prototype of an intelligent robot system based on 3D vision for real-time positioning of a milking robot has been built and tested under various conditions on a synthetic udder model (in static and moving scenarios). Experimental tests, were performed using 3D Time-Of-Flight (TOF) and RGBD cameras. The proposed algorithms permit the online segmentation of teats by combing 2D and 3D visual information. The obtained results permit the teat 3D position computation. This information is then sent to the milking robot for teat cups positioning. The vision system has a real-time performance and monitors the optimal positioning of the cups even in the presence of motion. The obtained results, with both TOF and RGBD cameras, show the good performance of the proposed system. The best performance was obtained with RGBD cameras. This latter technology will be used in future real life experimental tests.

  12. 47 CFR 3.2 - Terms and definitions.

    Science.gov (United States)

    2010-10-01

    ... is subject to IMF's definition. One of the monetary units used to effect accounting settlements in... 47 Telecommunication 1 2010-10-01 2010-10-01 false Terms and definitions. 3.2 Section 3.2 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL AUTHORIZATION AND ADMINISTRATION OF ACCOUNTING...

  13. Feasibility of a semi-automated contrast-oriented algorithm for tumor segmentation in retrospectively gated PET images: phantom and clinical validation

    Science.gov (United States)

    Carles, Montserrat; Fechter, Tobias; Nemer, Ursula; Nanko, Norbert; Mix, Michael; Nestle, Ursula; Schaefer, Andrea

    2015-12-01

    PET/CT plays an important role in radiotherapy planning for lung tumors. Several segmentation algorithms have been proposed for PET tumor segmentation. However, most of them do not take into account respiratory motion and are not well validated. The aim of this work was to evaluate a semi-automated contrast-oriented algorithm (COA) for PET tumor segmentation adapted to retrospectively gated (4D) images. The evaluation involved a wide set of 4D-PET/CT acquisitions of dynamic experimental phantoms and lung cancer patients. In addition, segmentation accuracy of 4D-COA was compared with four other state-of-the-art algorithms. In phantom evaluation, the physical properties of the objects defined the gold standard. In clinical evaluation, the ground truth was estimated by the STAPLE (Simultaneous Truth and Performance Level Estimation) consensus of three manual PET contours by experts. Algorithm evaluation with phantoms resulted in: (i) no statistically significant diameter differences for different targets and movements (Δ φ =0.3+/- 1.6 mm); (ii) reproducibility for heterogeneous and irregular targets independent of user initial interaction and (iii) good segmentation agreement for irregular targets compared to manual CT delineation in terms of Dice Similarity Coefficient (DSC  =  0.66+/- 0.04 ), Positive Predictive Value (PPV  =  0.81+/- 0.06 ) and Sensitivity (Sen.  =  0.49+/- 0.05 ). In clinical evaluation, the segmented volume was in reasonable agreement with the consensus volume (difference in volume (%Vol)  =  40+/- 30 , DSC  =  0.71+/- 0.07 and PPV  =  0.90+/- 0.13 ). High accuracy in target tracking position (Δ ME) was obtained for experimental and clinical data (Δ ME{{}\\text{exp}}=0+/- 3 mm; Δ ME{{}\\text{clin}}=0.3+/- 1.4 mm). In the comparison with other lung segmentation methods, 4D-COA has shown the highest volume accuracy in both experimental and clinical data. In conclusion, the accuracy in volume

  14. Investigation of the existence and uniqueness of extremal and positive definite solutions of nonlinear matrix equations

    Directory of Open Access Journals (Sweden)

    Abdel-Shakoor M Sarhan

    2016-05-01

    Full Text Available Abstract We consider two nonlinear matrix equations X r ± ∑ i = 1 m A i ∗ X δ i A i = I $X^{r} \\pm \\sum_{i = 1}^{m} A_{i}^{*}X^{\\delta_{i}}A_{i} = I$ , where − 1 < δ i < 0 $- 1 < \\delta_{i} < 0$ , and r, m are positive integers. For the first equation (plus case, we prove the existence of positive definite solutions and extremal solutions. Two algorithms and proofs of their convergence to the extremal positive definite solutions are constructed. For the second equation (negative case, we prove the existence and the uniqueness of a positive definite solution. Moreover, the algorithm given in (Duan et al. in Linear Algebra Appl. 429:110-121, 2008 (actually, in (Shi et al. in Linear Multilinear Algebra 52:1-15, 2004 for r = 1 $r = 1$ is proved to be valid for any r. Numerical examples are given to illustrate the performance and effectiveness of all the constructed algorithms. In Appendix, we analyze the ordering on the positive cone P ( n ‾ $\\overline{P(n}$ .

  15. A symmetric positive definite formulation for monolithic fluid structure interaction

    KAUST Repository

    Robinson-Mosher, Avi; Schroeder, Craig; Fedkiw, Ronald

    2011-01-01

    In this paper we consider a strongly coupled (monolithic) fluid structure interaction framework for incompressible flow, as opposed to a loosely coupled (partitioned) method. This requires solving a single linear system that combines the unknown velocities of the structure with the unknown pressures of the fluid. In our previous work, we were able to obtain a symmetric formulation of this coupled system; however, it was also indefinite, making it more difficult to solve. In fact in practice there have been cases where we have been unable to invert the system. In this paper we take a novel approach that consists of factoring the damping matrix of deformable structures and show that this can be used to obtain a symmetric positive definite system, at least to the extent that the uncoupled systems were symmetric positive definite. We use a traditional MAC grid discretization of the fluid and a fully Lagrangian discretization of the structures for the sake of exposition, noting that our procedure can be generalized to other scenarios. For the special case of rigid bodies, where there are no internal damping forces, we exactly recover the system of Batty et al. (2007) [4]. © 2010 Elsevier Inc.

  16. A symmetric positive definite formulation for monolithic fluid structure interaction

    KAUST Repository

    Robinson-Mosher, Avi

    2011-02-01

    In this paper we consider a strongly coupled (monolithic) fluid structure interaction framework for incompressible flow, as opposed to a loosely coupled (partitioned) method. This requires solving a single linear system that combines the unknown velocities of the structure with the unknown pressures of the fluid. In our previous work, we were able to obtain a symmetric formulation of this coupled system; however, it was also indefinite, making it more difficult to solve. In fact in practice there have been cases where we have been unable to invert the system. In this paper we take a novel approach that consists of factoring the damping matrix of deformable structures and show that this can be used to obtain a symmetric positive definite system, at least to the extent that the uncoupled systems were symmetric positive definite. We use a traditional MAC grid discretization of the fluid and a fully Lagrangian discretization of the structures for the sake of exposition, noting that our procedure can be generalized to other scenarios. For the special case of rigid bodies, where there are no internal damping forces, we exactly recover the system of Batty et al. (2007) [4]. © 2010 Elsevier Inc.

  17. D3D augmented reality imaging system: proof of concept in mammography.

    Science.gov (United States)

    Douglas, David B; Petricoin, Emanuel F; Liotta, Lance; Wilson, Eugene

    2016-01-01

    The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called "depth 3-dimensional (D3D) augmented reality". A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice.

  18. Learning to Grasp Unknown Objects Based on 3D Edge Information

    DEFF Research Database (Denmark)

    Bodenhagen, Leon; Kraft, Dirk; Popovic, Mila

    2010-01-01

    In this work we refine an initial grasping behavior based on 3D edge information by learning. Based on a set of autonomously generated evaluated grasps and relations between the semi-global 3D edges, a prediction function is learned that computes a likelihood for the success of a grasp using either...... an offline or an online learning scheme. Both methods are implemented using a hybrid artificial neural network containing standard nodes with a sigmoid activation function and nodes with a radial basis function. We show that a significant performance improvement can be achieved....

  19. Psychometric data concerning the Positive and Negative Affect Schedule – Direction (PANAS-D in athletes in Arabic-Tunisian language supporting a 2-factor structure of its short modified version

    Directory of Open Access Journals (Sweden)

    Sofiane Mnadla

    2017-04-01

    Full Text Available The Positive and Negative Affect Schedule – Direction (PANAS-D questionnaire was translated from the French version developed by Nicolas and coworkers into Arabic-Tunisian language and administered to a sample of 519 athletes (mean age 19.43±3.78 years; 230 male, 229 female; 75 competing at international level, 287 at national level, 130 at regional level, and 27 at local level. A semi-confirmatory factor analysis was carried out in order to shed light on the factor structure of the questionnaire. Different models were tested, including the 1-factor, the 2-factor and the 3-factor structure models, and compared in terms of fitting indexes. Data support a 2-factor solution of the modified short version of the PANAS-D questionnaire.

  20. Added diagnostic value of respiratory-gated 4D 18F-FDG PET/CT in the detection of liver lesions. A multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Crivellaro, Cinzia; Landoni, Claudio; Guerra, Luca [San Gerardo Hospital, Nuclear Medicine, Monza (Italy); University of Milan-Bicocca, Milan (Italy); De Ponti, Elena; Morzenti, Sabrina [San Gerardo Hospital, Medical Physics, Monza (Italy); Elisei, Federica [San Gerardo Hospital, Nuclear Medicine, Monza (Italy); Picchio, Maria; Bettinardi, Valentino [IRCCS San Raffaele Scientific Institute, Nuclear Medicine, Milan (Italy); Versari, Annibale [Santa Maria Nuova Hospital IRCCS, Nuclear Medicine, Reggio Emilia (Italy); Fioroni, Federica [Santa Maria Nuova Hospital IRCCS, Medical Physics, Reggio Emilia (Italy); Dziuk, Miroslaw; Tkaczewski, Konrad [Military Institute of Medicine, Warsaw (Poland); Ahond-Vionnet, Renee; Nodari, Guillaume [Hopital Pierre Beregovoy, Service de Medecine Nucleaire, Nevers (France); Todde, Sergio [University of Milan-Bicocca, Tecnomed Foundation, Monza (Italy)

    2018-01-15

    The aim of the present study was to evaluate the added diagnostic value of respiratory-gated 4D18F-FDG PET/CT in liver lesion detection and characterization in a European multicenter retrospective study. Fifty-six oncological patients (29 males and 27 females, mean age, 61.2 ± 11.2 years) from five European centers, submitted to standard 3D-PET/CT and liver 4D-PET/CT were retrospectively evaluated. Based on visual analysis, liver PET/CT findings were scored as positive, negative, or equivocal both in 3D and 4D PET/CT. The impact of 4D-PET/CT on the confidence in classifying liver lesions was assessed. PET/CT findings were compared to histology and clinical follow-up as standard reference and diagnostic accuracy was calculated for both techniques. At semi-quantitative analysis, SUVmax was calculated for each detected lesion in 3D and 4D-PET/CT. Overall, 72 liver lesions were considered for the analysis. Based on visual analysis in 3D-PET/CT, 32/72 (44.4%) lesions were considered positive, 21/72 (29.2%) negative, and 19/72 (26.4%) equivocal, while in 4D-PET/CT 48/72 (66.7%) lesions were defined positive, 23/72 (31.9%) negative, and 1/72 (1.4%) equivocal. 4D-PET/CT findings increased the confidence in lesion definition in 37/72 lesions (51.4%). Considering 3D equivocal lesions as positive, sensitivity, specificity, and accuracy were 88.9, 70.0, and 83.1%, respectively, while the same figures were 67.7, 90.0, and 73.8% if 3D equivocal findings were included as negative. 4D-PET/CT sensitivity, specificity, and accuracy were 97.8, 90.0, and 95.4%, respectively, considering equivocal lesions as positive and 95.6, 90.0, and 93.8% considering equivocal lesions as negative. The SUVmax of the liver lesions in 4D-PET (mean ± SD, 6.9 ± 3.2) was significantly higher (p < 0.001) than SUVmax in 3D-PET (mean ± SD, 5.2 ± 2.3). Respiratory-gated PET/CT technique is a valuable clinical tool in diagnosing liver lesions, reducing 3D undetermined findings, improving diagnostic

  1. DIY 3D printing of custom orthopaedic implants: a proof of concept study.

    Science.gov (United States)

    Frame, Mark; Leach, William

    2014-03-01

    3D printing is an emerging technology that is primarily used for aiding the design and prototyping of implants. As this technology has evolved it has now become possible to produce functional and definitive implants manufactured using a 3D printing process. This process, however, previously required a large financial investment in complex machinery and professionals skilled in 3D product design. Our pilot study's aim was to design and create a 3D printed custom orthopaedic implant using only freely available consumer hardware and software.

  2. [Case of awake intubation in semi-sitting position for a patient with myasthenia gravis combined with cervical disc hernia utilizing Pentax-AWS Airwayscope].

    Science.gov (United States)

    Komasawa, Nobuyasu; Ueki, Ryusuke; Tomita, Yukihiko; Kaminoh, Yoshiroh; Tashiro, Chikara

    2011-01-01

    We report a case of awake intubation utilizing Pentax-AWS Airwayscope in semi-sitting position. A 74-year-old man with myasthenia gravis and cervical disc hernia was scheduled for distal gastrectomy under general anesthesia. He could not move his head due to severe cervical disc hernia and also could not sufficiently breathe due to the fatigue of respiratory muscles by myasthenia gravis in supine position. With fentanyl bolus administration and lidocaine spray for laryngotracheal anesthesia, we performed awake intubation in semi-sitting position with AWS from cranial side. The patient did not buck during intubation and no hemodynamic change was observed.

  3. 25-hydroxyvitamin D3 and 1,25-dihydroxyvitamin D3 exert distinct effects on human skeletal muscle function and gene expression.

    Directory of Open Access Journals (Sweden)

    Zaki K Hassan-Smith

    Full Text Available Age-associated decline in muscle function represents a significant public health burden. Vitamin D-deficiency is also prevalent in aging subjects, and has been linked to loss of muscle mass and strength (sarcopenia, but the precise role of specific vitamin D metabolites in determining muscle phenotype and function is still unclear. To address this we quantified serum concentrations of multiple vitamin D metabolites, and assessed the impact of these metabolites on body composition/muscle function parameters, and muscle biopsy gene expression in a retrospective study of a cohort of healthy volunteers. Active serum 1,25-dihydroxyvitamin D3 (1α,25(OH2D3, but not inactive 25-hydroxyvitamin D3 (25OHD3, correlated positively with measures of lower limb strength including power (rho = 0.42, p = 0.02, velocity (Vmax, rho = 0.40, p = 0.02 and jump height (rho = 0.36, p = 0.04. Lean mass correlated positively with 1α,25(OH2D3 (rho = 0.47, p = 0.02, in women. Serum 25OHD3 and inactive 24,25-dihydroxyvitamin D3 (24,25(OH2D3 had an inverse relationship with body fat (rho = -0.30, p = 0.02 and rho = -0.33, p = 0.01, respectively. Serum 25OHD3 and 24,25(OH2D3 were also correlated with urinary steroid metabolites, suggesting a link with glucocorticoid metabolism. PCR array analysis of 92 muscle genes identified vitamin D receptor (VDR mRNA in all muscle biopsies, with this expression being negatively correlated with serum 25OHD3, and Vmax, and positively correlated with fat mass. Of the other 91 muscle genes analysed by PCR array, 24 were positively correlated with 25OHD3, but only 4 were correlated with active 1α,25(OH2D3. These data show that although 25OHD3 has potent actions on muscle gene expression, the circulating concentrations of this metabolite are more closely linked to body fat mass, suggesting that 25OHD3 can influence muscle function via indirect effects on adipose tissue. By contrast, serum 1α,25(OH2D3 has limited effects on muscle gene

  4. 3D statistical shape models incorporating 3D random forest regression voting for robust CT liver segmentation

    Science.gov (United States)

    Norajitra, Tobias; Meinzer, Hans-Peter; Maier-Hein, Klaus H.

    2015-03-01

    During image segmentation, 3D Statistical Shape Models (SSM) usually conduct a limited search for target landmarks within one-dimensional search profiles perpendicular to the model surface. In addition, landmark appearance is modeled only locally based on linear profiles and weak learners, altogether leading to segmentation errors from landmark ambiguities and limited search coverage. We present a new method for 3D SSM segmentation based on 3D Random Forest Regression Voting. For each surface landmark, a Random Regression Forest is trained that learns a 3D spatial displacement function between the according reference landmark and a set of surrounding sample points, based on an infinite set of non-local randomized 3D Haar-like features. Landmark search is then conducted omni-directionally within 3D search spaces, where voxelwise forest predictions on landmark position contribute to a common voting map which reflects the overall position estimate. Segmentation experiments were conducted on a set of 45 CT volumes of the human liver, of which 40 images were randomly chosen for training and 5 for testing. Without parameter optimization, using a simple candidate selection and a single resolution approach, excellent results were achieved, while faster convergence and better concavity segmentation were observed, altogether underlining the potential of our approach in terms of increased robustness from distinct landmark detection and from better search coverage.

  5. 48 CFR 3.1001 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Definitions. 3.1001 Section 3.1001 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL IMPROPER BUSINESS PRACTICES AND PERSONAL CONFLICTS OF INTEREST Contractor Code of Business Ethics and Conduct 3.1001...

  6. Positive Behavior Support: A Proposal for Updating and Refining the Definition

    Science.gov (United States)

    Kincaid, Don; Dunlap, Glen; Kern, Lee; Lane, Kathleen Lynne; Bambara, Linda M.; Brown, Fredda; Fox, Lise; Knoster, Timothy P.

    2016-01-01

    Positive behavior support (PBS) has been a dynamic and growing enterprise for more than 25 years. During this period, PBS has expanded applications across a wide range of populations and multiple levels of implementation. As a result, there have been understandable inconsistencies and confusion regarding the definition of PBS. In this essay, we…

  7. 3D FE simulation of semi-finishing machining of Ti6Al4V additively manufactured by direct metal laser sintering

    Science.gov (United States)

    Imbrogno, Stano; Rinaldi, Sergio; Raso, Antonio; Bordin, Alberto; Bruschi, Stefania; Umbrello, Domenico

    2018-05-01

    The Additive Manufacturing techniques are gaining more and more interest in various industrial fields due to the possibility of drastically reduce the material waste during the production processes, revolutionizing the standard scheme and strategies of the manufacturing processes. However, the metal parts shape produced, frequently do not satisfy the tolerances as well as the surface quality requirements. During the design phase, the finite element simulation results a fundamental tool to help the engineers in the correct decision of the most suitable process parameters, especially in manufacturing processes, in order to produce products of high quality. The aim of this work is to develop a 3D finite element model of semi-finishing turning operation of Ti6Al4V, produced via Direct Metal Laser Sintering (DMLS). A customized user sub-routine was built-up in order to model the mechanical behavior of the material under machining operations to predict the main fundamental variables as cutting forces and temperature. Moreover, the machining induced alterations are also studied by the finite element model developed.

  8. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  9. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  10. 3D staggered Lagrangian hydrodynamics scheme with cell-centered Riemann solver-based artificial viscosity

    International Nuclear Information System (INIS)

    Loubere, Raphael; Maire, Pierre-Henri; Vachal, Pavel

    2013-01-01

    The aim of the present work is the 3D extension of a general formalism to derive a staggered discretization for Lagrangian hydrodynamics on unstructured grids. The classical compatible discretization is used; namely, momentum equation is discretized using the fundamental concept of subcell forces. Specific internal energy equation is obtained using total energy conservation. The subcell force is derived by invoking the Galilean invariance and thermodynamic consistency. A general form of the subcell force is provided so that a cell entropy inequality is satisfied. The subcell force consists of a classical pressure term plus a tensorial viscous contribution proportional to the difference between the node velocity and the cell-centered velocity. This cell-centered velocity is an extra degree of freedom solved with a cell-centered approximate Riemann solver. The second law of thermodynamics is satisfied by construction of the local positive definite subcell tensor involved in the viscous term. A particular expression of this tensor is proposed. A more accurate extension of this discretization both in time and space is also provided using a piecewise linear reconstruction of the velocity field and a predictor-corrector time discretization. Numerical tests are presented in order to assess the efficiency of this approach in 3D. Sanity checks show that the 3D extension of the 2D approach reproduces 1D and 2D results. Finally, 3D problems such as Sedov, Noh, and Saltzman are simulated. (authors)

  11. Utility of semi-rigid thoracoscopy in undiagnosed exudative pleural effusion.

    Science.gov (United States)

    Nattusamy, Loganathan; Madan, Karan; Mohan, Anant; Hadda, Vijay; Jain, Deepali; Madan, Neha Kawatra; Arava, Sudheer; Khilnani, Gopi C; Guleria, Randeep

    2015-01-01

    Semi-rigid thoracoscopy is a safe and efficacious procedure in patients with undiagnosed pleural effusion. Literature on its utility from developing countries is limited. We herein describe our initial experience on the utility of semi-rigid thoracoscopy from a tertiary care teaching and referral center in north India. We also perform a systematic review of studies reporting the utility of semi-rigid thoracoscopy from India. The primary objective was to evaluate the diagnostic utility of semi-rigid thoracoscopy in patients with undiagnosed exudative pleural effusion. Semi-rigid thoracoscopy was performed under local anesthesia and conscious sedation in the bronchoscopy suite. A total of 48 patients underwent semi-rigid thoracoscopy between August 2012 and December 2013 for undiagnosed pleural effusion. Mean age was 50.9 ± 14.1 years (range: 17-78 years). Pre-procedure clinico-radiological diagnoses were malignant pleural effusion [36 patients (75%)], tuberculosis (TB) [10 (20.83%) patients], and empyema [2 patients (4.17%)]. Patients with empyema underwent the procedure for pleural biopsy, optimal placement of intercostal tube and adhesiolysis. Thoracoscopic pleural biopsy diagnosed pleural malignancy in 30 (62.5%) patients and TB in 2 (4.17%) patients. Fourteen (29.17%) patients were diagnosed with non-specific pleuritis and normal pleura was diagnosed on a pleural biopsy in 2 (4.17%) patients. Overall, a definitive diagnosis of either pleural malignancy or TB was obtained in 32 (66.7%) patients. Combined overall sensitivity, specificity, positive predictive value and negative predictive value of thoracoscopic pleural biopsy for malignant pleural effusion were 96.77%, 100%, 100% and 66.67%, respectively. There was no procedure-related mortality. On performing a systematic review of literature, four studies on semi-rigid thoracoscopy from India were identified. Semi-rigid thoracoscopy is a safe and efficacious procedure in patients with undiagnosed exudative

  12. Interactive 3d Landscapes on Line

    Science.gov (United States)

    Fanini, B.; Calori, L.; Ferdani, D.; Pescarin, S.

    2011-09-01

    The paper describes challenges identified while developing browser embedded 3D landscape rendering applications, our current approach and work-flow and how recent development in browser technologies could affect. All the data, even if processed by optimization and decimation tools, result in very huge databases that require paging, streaming and Level-of-Detail techniques to be implemented to allow remote web based real time fruition. Our approach has been to select an open source scene-graph based visual simulation library with sufficient performance and flexibility and adapt it to the web by providing a browser plug-in. Within the current Montegrotto VR Project, content produced with new pipelines has been integrated. The whole Montegrotto Town has been generated procedurally by CityEngine. We used this procedural approach, based on algorithms and procedures because it is particularly functional to create extensive and credible urban reconstructions. To create the archaeological sites we used optimized mesh acquired with laser scanning and photogrammetry techniques whereas to realize the 3D reconstructions of the main historical buildings we adopted computer-graphic software like blender and 3ds Max. At the final stage, semi-automatic tools have been developed and used up to prepare and clusterise 3D models and scene graph routes for web publishing. Vegetation generators have also been used with the goal of populating the virtual scene to enhance the user perceived realism during the navigation experience. After the description of 3D modelling and optimization techniques, the paper will focus and discuss its results and expectations.

  13. INTERACTIVE 3D LANDSCAPES ON LINE

    Directory of Open Access Journals (Sweden)

    B. Fanini

    2012-09-01

    Full Text Available The paper describes challenges identified while developing browser embedded 3D landscape rendering applications, our current approach and work-flow and how recent development in browser technologies could affect. All the data, even if processed by optimization and decimation tools, result in very huge databases that require paging, streaming and Level-of-Detail techniques to be implemented to allow remote web based real time fruition. Our approach has been to select an open source scene-graph based visual simulation library with sufficient performance and flexibility and adapt it to the web by providing a browser plug-in. Within the current Montegrotto VR Project, content produced with new pipelines has been integrated. The whole Montegrotto Town has been generated procedurally by CityEngine. We used this procedural approach, based on algorithms and procedures because it is particularly functional to create extensive and credible urban reconstructions. To create the archaeological sites we used optimized mesh acquired with laser scanning and photogrammetry techniques whereas to realize the 3D reconstructions of the main historical buildings we adopted computer-graphic software like blender and 3ds Max. At the final stage, semi-automatic tools have been developed and used up to prepare and clusterise 3D models and scene graph routes for web publishing. Vegetation generators have also been used with the goal of populating the virtual scene to enhance the user perceived realism during the navigation experience. After the description of 3D modelling and optimization techniques, the paper will focus and discuss its results and expectations.

  14. Semi-quantitative assessment of right ventricular function in comparison to a 3D volumetric approach: A cardiovascular magnetic resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Nijveldt, Robin; Germans, Tjeerd; Rossum, Albert C. van [VU University Medical Center, Department of Cardiology, Amsterdam (Netherlands); Interuniversity Cardiology Institute of the Netherlands, Utrecht (Netherlands); McCann, Gerald P. [University Hospitals Leicester, Department of Cardiology, Leicester (United Kingdom); Beek, Aernout M. [VU University Medical Center, Department of Cardiology, Amsterdam (Netherlands)

    2008-11-15

    Right ventricular (RV) volume measurements with cardiovascular magnetic resonance (CMR) is considered the gold standard, but acquisition and analysis remain time-consuming. The aim of our study was therefore to investigate the accuracy and performance of a semi-quantitative assessment of RV function in CMR, compared to the standard quantitative approach. Seventy-five subjects with pulmonary hypertension (15), anterior myocardial infarction (15), inferior myocardial infarction (15), Brugada syndrome (15) and normal subjects (15) underwent cine CMR. RV end-systolic and end-diastolic volumes were determined to calculate RV ejection fraction (EF). Four-chamber cine images were used to measure tricuspid annular plane systolic excursion (TAPSE). RV fractional shortening (RVFS) was calculated by dividing TAPSE by the RV end-diastolic length. RV EF correlated significantly with TAPSE (r = 0.62, p < 0.01) and RVFS (r = 0.67, p < 0.01). Sensitivity to predict RV dysfunction was comparable between TAPSE and RVFS, with higher specificity for RVFS, but comparable areas under the ROC curve. Intra- and inter-observer variability of RV EF was better than TAPSE (3%/4% versus 7%/15%, respectively). For routine screening in clinical practice, TAPSE and RVFS seem reliable and easy methods to identify patients with RV dysfunction. The 3D volumetric approach is preferred to assess RV function for research purposes or to evaluate treatment response. (orig.)

  15. Emergence of 3D Printed Dosage Forms: Opportunities and Challenges.

    Science.gov (United States)

    Alhnan, Mohamed A; Okwuosa, Tochukwu C; Sadia, Muzna; Wan, Ka-Wai; Ahmed, Waqar; Arafat, Basel

    2016-08-01

    The recent introduction of the first FDA approved 3D-printed drug has fuelled interest in 3D printing technology, which is set to revolutionize healthcare. Since its initial use, this rapid prototyping (RP) technology has evolved to such an extent that it is currently being used in a wide range of applications including in tissue engineering, dentistry, construction, automotive and aerospace. However, in the pharmaceutical industry this technology is still in its infancy and its potential yet to be fully explored. This paper presents various 3D printing technologies such as stereolithographic, powder based, selective laser sintering, fused deposition modelling and semi-solid extrusion 3D printing. It also provides a comprehensive review of previous attempts at using 3D printing technologies on the manufacturing dosage forms with a particular focus on oral tablets. Their advantages particularly with adaptability in the pharmaceutical field have been highlighted, which enables the preparation of dosage forms with complex designs and geometries, multiple actives and tailored release profiles. An insight into the technical challenges facing the different 3D printing technologies such as the formulation and processing parameters is provided. Light is also shed on the different regulatory challenges that need to be overcome for 3D printing to fulfil its real potential in the pharmaceutical industry.

  16. 3D site specific sample preparation and analysis of 3D devices (FinFETs) by atom probe tomography.

    Science.gov (United States)

    Kambham, Ajay Kumar; Kumar, Arul; Gilbert, Matthieu; Vandervorst, Wilfried

    2013-09-01

    With the transition from planar to three-dimensional device architectures such as Fin field-effect-transistors (FinFETs), new metrology approaches are required to meet the needs of semiconductor technology. It is important to characterize the 3D-dopant distributions precisely as their extent, positioning relative to gate edges and absolute concentration determine the device performance in great detail. At present the atom probe has shown its ability to analyze dopant distributions in semiconductor and thin insulating materials with sub-nm 3D-resolution and good dopant sensitivity. However, so far most reports have dealt with planar devices or restricted the measurements to 2D test structures which represent only limited challenges in terms of localization and site specific sample preparation. In this paper we will discuss the methodology to extract the dopant distribution from real 3D-devices such as a 3D-FinFET device, requiring the sample preparation to be carried out at a site specific location with a positioning accuracy ∼50 nm. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. 3D super-virtual refraction interferometry

    KAUST Repository

    Lu, Kai; AlTheyab, Abdullah; Schuster, Gerard T.

    2014-01-01

    Super-virtual refraction interferometry enhances the signal-to-noise ratio of far-offset refractions. However, when applied to 3D cases, traditional 2D SVI suffers because the stationary positions of the source-receiver pairs might be any place

  18. Developing a Low-Cost System for 3d Data Acquisition

    Science.gov (United States)

    Kossieris, S.; Kourounioti, O.; Agrafiotis, P.; Georgopoulos, A.

    2017-11-01

    In this paper, a developed low-cost system is described, which aims to facilitate 3D documentation fast and reliably by acquiring the necessary data in outdoor environment for the 3D documentation of façades especially in the case of very narrow streets. In particular, it provides a viable solution for buildings up to 8-10m high and streets as narrow as 2m or even less. In cases like that, it is practically impossible or highly time-consuming to acquire images in a conventional way. This practice would lead to a huge number of images and long processing times. The developed system was tested in the narrow streets of a medieval village on the Greek island of Chios. There, in order to by-pass the problem of short taking distances, it was thought to use high definition action cameras together with a 360˚ camera, which are usually provided with very wide-angle lenses and are capable of acquiring images, of high definition, are rather cheap and, most importantly, extremely light. Results suggest that the system can perform fast 3D data acquisition adequate for deliverables of high quality.

  19. Numerical Simulation of 3-D Wave Crests

    Institute of Scientific and Technical Information of China (English)

    YU Dingyong; ZHANG Hanyuan

    2003-01-01

    A clear definition of 3-D wave crest and a description of the procedures to detect the boundary of wave crest are presented in the paper. By using random wave theory and directional wave spectrum, a MATLAB-platformed program is designed to simulate random wave crests for various directional spectral conditions in deep water. Statistics of wave crests with different directional spreading parameters and different directional functions are obtained and discussed.

  20. Positive zeta potential of a negatively charged semi-permeable plasma membrane

    Science.gov (United States)

    Sinha, Shayandev; Jing, Haoyuan; Das, Siddhartha

    2017-08-01

    The negative charge of the plasma membrane (PM) severely affects the nature of moieties that may enter or leave the cells and controls a large number of ion-interaction-mediated intracellular and extracellular events. In this letter, we report our discovery of a most fascinating scenario, where one interface (e.g., membrane-cytosol interface) of the negatively charged PM shows a positive surface (or ζ) potential, while the other interface (e.g., membrane-electrolyte interface) still shows a negative ζ potential. Therefore, we encounter a completely unexpected situation where an interface (e.g., membrane-cytosol interface) that has a negative surface charge density demonstrates a positive ζ potential. We establish that the attainment of such a property by the membrane can be ascribed to an interplay of the nature of the membrane semi-permeability and the electrostatics of the electric double layer established on either side of the charged membrane. We anticipate that such a membrane property can lead to such capabilities of the cell (in terms of accepting or releasing certain kinds of moieties as well regulating cellular signaling) that was hitherto inconceivable.

  1. Infra Red 3D Computer Mouse

    DEFF Research Database (Denmark)

    Harbo, Anders La-Cour; Stoustrup, Jakob

    2000-01-01

    The infra red 3D mouse is a three dimensional input device to a computer. It works by determining the position of an arbitrary object (like a hand) by emitting infra red signals from a number of locations and measuring the reflected intensities. To maximize stability, robustness, and use of bandw......The infra red 3D mouse is a three dimensional input device to a computer. It works by determining the position of an arbitrary object (like a hand) by emitting infra red signals from a number of locations and measuring the reflected intensities. To maximize stability, robustness, and use...

  2. Optoelectronic interconnects for 3D wafer stacks

    Science.gov (United States)

    Ludwig, David; Carson, John C.; Lome, Louis S.

    1996-01-01

    Wafer and chip stacking are envisioned as means of providing increased processing power within the small confines of a three-dimensional structure. Optoelectronic devices can play an important role in these dense 3-D processing electronic packages in two ways. In pure electronic processing, optoelectronics can provide a method for increasing the number of input/output communication channels within the layers of the 3-D chip stack. Non-free space communication links allow the density of highly parallel input/output ports to increase dramatically over typical edge bus connections. In hybrid processors, where electronics and optics play a role in defining the computational algorithm, free space communication links are typically utilized for, among other reasons, the increased network link complexity which can be achieved. Free space optical interconnections provide bandwidths and interconnection complexity unobtainable in pure electrical interconnections. Stacked 3-D architectures can provide the electronics real estate and structure to deal with the increased bandwidth and global information provided by free space optical communications. This paper will provide definitions and examples of 3-D stacked architectures in optoelectronics processors. The benefits and issues of these technologies will be discussed.

  3. Novel real-time 3D radiological mapping solution for ALARA maximization, D and D assessments and radiological management

    Energy Technology Data Exchange (ETDEWEB)

    Dubart, Philippe; Hautot, Felix [AREVA Group, 1 route de la Noue, Gif sur Yvette (France); Morichi, Massimo; Abou-Khalil, Roger [AREVA Group, Tour AREVA-1, place Jean Millier, Paris (France)

    2015-07-01

    Good management of dismantling and decontamination (D and D) operations and activities is requiring safety, time saving and perfect radiological knowledge of the contaminated environment as well as optimization for personnel dose and minimization of waste volume. In the same time, Fukushima accident has imposed a stretch to the nuclear measurement operational approach requiring in such emergency situation: fast deployment and intervention, quick analysis and fast scenario definition. AREVA, as return of experience from his activities carried out at Fukushima and D and D sites has developed a novel multi-sensor solution as part of his D and D research, approach and method, a system with real-time 3D photo-realistic spatial radiation distribution cartography of contaminated premises. The system may be hand-held or mounted on a mobile device (robot, drone, e.g). In this paper, we will present our current development based on a SLAM technology (Simultaneous Localization And Mapping) and integrated sensors and detectors allowing simultaneous topographic and radiological (dose rate and/or spectroscopy) data acquisitions. This enabling technology permits 3D gamma activity cartography in real-time. (authors)

  4. Novel real-time 3D radiological mapping solution for ALARA maximization, D and D assessments and radiological management

    International Nuclear Information System (INIS)

    Dubart, Philippe; Hautot, Felix; Morichi, Massimo; Abou-Khalil, Roger

    2015-01-01

    Good management of dismantling and decontamination (D and D) operations and activities is requiring safety, time saving and perfect radiological knowledge of the contaminated environment as well as optimization for personnel dose and minimization of waste volume. In the same time, Fukushima accident has imposed a stretch to the nuclear measurement operational approach requiring in such emergency situation: fast deployment and intervention, quick analysis and fast scenario definition. AREVA, as return of experience from his activities carried out at Fukushima and D and D sites has developed a novel multi-sensor solution as part of his D and D research, approach and method, a system with real-time 3D photo-realistic spatial radiation distribution cartography of contaminated premises. The system may be hand-held or mounted on a mobile device (robot, drone, e.g). In this paper, we will present our current development based on a SLAM technology (Simultaneous Localization And Mapping) and integrated sensors and detectors allowing simultaneous topographic and radiological (dose rate and/or spectroscopy) data acquisitions. This enabling technology permits 3D gamma activity cartography in real-time. (authors)

  5. Simplifying the exploration of volumetric images: development of a 3D user interface for the radiologist's workplace.

    Science.gov (United States)

    Teistler, M; Breiman, R S; Lison, T; Bott, O J; Pretschner, D P; Aziz, A; Nowinski, W L

    2008-10-01

    Volumetric imaging (computed tomography and magnetic resonance imaging) provides increased diagnostic detail but is associated with the problem of navigation through large amounts of data. In an attempt to overcome this problem, a novel 3D navigation tool has been designed and developed that is based on an alternative input device. A 3D mouse allows for simultaneous definition of position and orientation of orthogonal or oblique multiplanar reformatted images or slabs, which are presented within a virtual 3D scene together with the volume-rendered data set and additionally as 2D images. Slabs are visualized with maximum intensity projection, average intensity projection, or standard volume rendering technique. A prototype has been implemented based on PC technology that has been tested by several radiologists. It has shown to be easily understandable and usable after a very short learning phase. Our solution may help to fully exploit the diagnostic potential of volumetric imaging by allowing for a more efficient reading process compared to currently deployed solutions based on conventional mouse and keyboard.

  6. 3D GIS spatial operation based on extended Euler operators

    Science.gov (United States)

    Xu, Hongbo; Lu, Guonian; Sheng, Yehua; Zhou, Liangchen; Guo, Fei; Shang, Zuoyan; Wang, Jing

    2008-10-01

    The implementation of 3 dimensions spatial operations, based on certain data structure, has a lack of universality and is not able to treat with non-manifold cases, at present. ISO/DIS 19107 standard just presents the definition of Boolean operators and set operators for topological relationship query, and OGC GeoXACML gives formal definitions for several set functions without implementation detail. Aiming at these problems, based mathematical foundation on cell complex theory, supported by non-manifold data structure and using relevant research in the field of non-manifold geometry modeling for reference, firstly, this paper according to non-manifold Euler-Poincaré formula constructs 6 extended Euler operators and inverse operators to carry out creating, updating and deleting 3D spatial elements, as well as several pairs of supplementary Euler operators to convenient for implementing advanced functions. Secondly, we change topological element operation sequence of Boolean operation and set operation as well as set functions defined in GeoXACML into combination of extended Euler operators, which separates the upper functions and lower data structure. Lastly, we develop underground 3D GIS prototype system, in which practicability and credibility of extended Euler operators faced to 3D GIS presented by this paper are validated.

  7. Monte Carlo simulations towards semi-quantitative prompt gamma activation imaging

    International Nuclear Information System (INIS)

    Kis, Zoltan; Belgya, Tamas; Szentmiklosi, Laszlo

    2011-01-01

    Numerous non-destructive techniques utilize neutron attenuation, scattering or capture to gain morphological, structural or elemental information about the material under study. However, few attempts have been made so far to use neutron-induced gamma radiation for 3D element mapping. The first ever facility using direct scanning for element imaging was set up at the Budapest Research Reactor. It was shown that the position-sensitive prompt-gamma detection (PGAI) enables us to determine the spatial distribution of major elements. Iterative Monte Carlo simulation technique has also been developed to provide not only qualitative but also semi-quantitative element distribution of a simple object.

  8. SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M; Feigenberg, S [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patient position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures

  9. SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

    International Nuclear Information System (INIS)

    Lin, M; Feigenberg, S

    2015-01-01

    Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patient position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures

  10. On the Viability of Semi-Compatibilism

    Directory of Open Access Journals (Sweden)

    Ishtiyaque Haji

    2009-12-01

    Full Text Available Semi-compatibilism regarding responsibility is the position according to which determinism is compatible with moral responsibility quite apart from whether determinism rules out the sort of freedom that involves access to alternative possibilities. I motivate the view that whether or not semi-compatiblism is viable turns on whether various prima facie attractive normative principles are true or false. I introduce a subset of these principles. I then map out some positions regarding the tenability of semi-compatibilism depending upon which of these principles, if any, is true. I conclude that for many, the price of maintaining semi-compatibilism may be too steep because maintaining semi-compatibilism requires abandoning one or more of the principles in this subset.

  11. Towards the graviton from spinfoams: the 3d toy model

    International Nuclear Information System (INIS)

    Speziale, Simone

    2006-01-01

    Recently, a proposal has appeared for the extraction of the 2-point function of linearised quantum gravity, within the spinfoam formalism. This relies on the use of a boundary state, which introduces a semi-classical flat geometry on the boundary. In this paper, we investigate this proposal considering a toy model in the (Riemannian) 3d case, where the semi-classical limit is better understood. We show that in this limit the propagation kernel of the model is the one for the harmonic oscillator. This is at the origin of the expected 1/l behaviour of the 2-point function. Furthermore, we numerically study the short scales regime, where deviations from this behaviour occur

  12. Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial x-rays images data.

    Science.gov (United States)

    Cresson, T; Chav, R; Branchaud, D; Humbert, L; Godbout, B; Aubert, B; Skalli, W; De Guise, J A

    2009-01-01

    3D reconstructions of the spine from a frontal and sagittal radiographs is extremely challenging. The overlying features of soft tissues and air cavities interfere with image processing. It is also difficult to obtain information that is accurate enough to reconstruct complete 3D models. To overcome these problems, the proposed method efficiently combines the partial information contained in two images from a patient with a statistical 3D spine model generated from a database of scoliotic patients. The algorithm operates through two simultaneous iterating processes. The first one generates a personalized vertebra model using a 2D/3D registration process with bone boundaries extracted from radiographs, while the other one infers the position and the shape of other vertebrae from the current estimation of the registration process using a statistical 3D model. Experimental evaluations have shown good performances of the proposed approach in terms of accuracy and robustness when compared to CT-scan.

  13. Combined use of high-definition and volumetric optical coherence tomography for the segmentation of neural canal opening in cases of optic nerve edema

    Science.gov (United States)

    Wang, Jui-Kai; Kardon, Randy H.; Garvin, Mona K.

    2015-03-01

    In cases of optic-nerve-head edema, the presence of the swelling reduces the visibility of the underlying neural canal opening (NCO) within spectral-domain optical coherence tomography (SD-OCT) volumes. Consequently, traditional SD-OCT-based NCO segmentation methods often overestimate the size of the NCO. The visibility of the NCO can be improved using high-definition 2D raster scans, but such scans do not provide 3D contextual image information. In this work, we present a semi-automated approach for the segmentation of the NCO in cases of optic disc edema by combining image information from volumetric and high-definition raster SD-OCT image sequences. In particular, for each subject, five high-definition OCT B-scans and the OCT volume are first separately segmented, and then the five high-definition B-scans are automatically registered to the OCT volume. Next, six NCO points are placed (manually, in this work) in the central three high-definition OCT B-scans (two points for each central B-scans) and are automatically transferred into the OCT volume. Utilizing a combination of these mapped points and the 3D image information from the volumetric scans, a graph-based approach is used to identify the complete NCO on the OCT en-face image. The segmented NCO points using the new approach were significantly closer to expert-marked points than the segmented NCO points using a traditional approach (root mean square differences in pixels: 5.34 vs. 21.71, p < 0.001).

  14. 32 CFR 562.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Definitions. 562.3 Section 562.3 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY ORGANIZED RESERVES RESERVE OFFICERS' TRAINING CORPS... area. Region commanders are located at: (1) US Army First ROTC Region, Fort Bragg, NC 28307. (2) US...

  15. 44 CFR 354.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Definitions. 354.3 Section 354.3 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS FEE FOR SERVICES TO SUPPORT FEMA'S OFFSITE RADIOLOGICAL EMERGENCY PREPAREDNESS...

  16. 3D asthenopia in horizontal deviation.

    Science.gov (United States)

    Kim, Seung-Hyun; Suh, Young-Woo; Yun, Cheol-Min; Yoo, Eun-Joo; Yeom, Ji-Hyun; Cho, Yoonae A

    2013-05-01

    This study was conducted to investigate the asthenopic symptoms in patients with exotropia and esotropia while watching stereoscopic 3D (S3D) television (TV). A total 77 subjects who more than 9 years of age were enrolled in this study. We divided them into three groups; Thirty-four patients with exodeviation (Exo group), 11 patients with esodeviation (Eso group) and 32 volunteers with normal binocular vision (control group). The S3D images were shown to all patients with S3D high-definition TV for a period of 20 min. Best corrected visual acuity, refractive errors, angle of strabismus, stereopsis test and history of strabismus surgery, were evaluated. After watching S3D TV for 20 min, a survey of subjective symptoms was conducted with a questionnaire to evaluate the degree of S3D perception and asthenopic symptoms such as headache, dizziness and ocular fatigue while watching 3D TV. The mean amounts of deviation in the Exo group and Eso group were 11.2 PD and 7.73PD, respectively. Mean stereoacuity was 102.7 arc sec in the the Exo group and 1389.1 arc sec in the Eso group. In the control group, it was 41.9 arc sec. Twenty-nine patients in the Exo group showed excellent stereopsis (≤60 arc sec at near), but all 11 subjects of the Eso group showed 140 arc sec or worse and showed more decreased 3D perception than the Exo and the control group (p Kruskal-Wallis test). The Exo group reported more eye fatigue (p Kruskal-Wallis test) than the Eso and the control group. However, the scores of ocular fatigue in the patients who had undergone corrective surgery were less than in the patients who had not in the Exo group (p Kruskal-Wallis test) and the amount of exodeviation was not correlated with the asthenopic symptoms (dizziness, r = 0.034, p = 0.33; headache, r = 0.320, p = 0.119; eye fatigue, r = 0.135, p = 0.519, Spearman rank correlation test, respectively). Symptoms of 3D asthenopia were related to the presence of exodeviation but not to esodeviation. This may

  17. 24 CFR 3288.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Definitions. 3288.3 Section 3288.3... “manufactured home” as defined in 24 CFR 3280.2. Manufactured Housing Consensus Committee or MHCC means the consensus committee established pursuant to section 604(a)(3) of the Act, 42 U.S.C. 5403(a)(3). Party or...

  18. Development of 3D statistical mandible models for cephalometric measurements

    International Nuclear Information System (INIS)

    Kim, Sung Goo; Yi, Won Jin; Hwang, Soon Jung; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Hong, Helen; Yoo, Ji Hyun

    2012-01-01

    The aim of this study was to provide sex-matched three-dimensional (3D) statistical shape models of the mandible, which would provide cephalometric parameters for 3D treatment planning and cephalometric measurements in orthognathic surgery. The subjects used to create the 3D shape models of the mandible included 23 males and 23 females. The mandibles were segmented semi-automatically from 3D facial CT images. Each individual mandible shape was reconstructed as a 3D surface model, which was parameterized to establish correspondence between different individual surfaces. The principal component analysis (PCA) applied to all mandible shapes produced a mean model and characteristic models of variation. The cephalometric parameters were measured directly from the mean models to evaluate the 3D shape models. The means of the measured parameters were compared with those from other conventional studies. The male and female 3D statistical mean models were developed from 23 individual mandibles, respectively. The male and female characteristic shapes of variation produced by PCA showed a large variability included in the individual mandibles. The cephalometric measurements from the developed models were very close to those from some conventional studies. We described the construction of 3D mandibular shape models and presented the application of the 3D mandibular template in cephalometric measurements. Optimal reference models determined from variations produced by PCA could be used for craniofacial patients with various types of skeletal shape.

  19. Development of 3D statistical mandible models for cephalometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Goo; Yi, Won Jin; Hwang, Soon Jung; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il [School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Hong, Helen; Yoo, Ji Hyun [Division of Multimedia Engineering, Seoul Women' s University, Seoul (Korea, Republic of)

    2012-09-15

    The aim of this study was to provide sex-matched three-dimensional (3D) statistical shape models of the mandible, which would provide cephalometric parameters for 3D treatment planning and cephalometric measurements in orthognathic surgery. The subjects used to create the 3D shape models of the mandible included 23 males and 23 females. The mandibles were segmented semi-automatically from 3D facial CT images. Each individual mandible shape was reconstructed as a 3D surface model, which was parameterized to establish correspondence between different individual surfaces. The principal component analysis (PCA) applied to all mandible shapes produced a mean model and characteristic models of variation. The cephalometric parameters were measured directly from the mean models to evaluate the 3D shape models. The means of the measured parameters were compared with those from other conventional studies. The male and female 3D statistical mean models were developed from 23 individual mandibles, respectively. The male and female characteristic shapes of variation produced by PCA showed a large variability included in the individual mandibles. The cephalometric measurements from the developed models were very close to those from some conventional studies. We described the construction of 3D mandibular shape models and presented the application of the 3D mandibular template in cephalometric measurements. Optimal reference models determined from variations produced by PCA could be used for craniofacial patients with various types of skeletal shape.

  20. A Comparison of Iterative 2D-3D Pose Estimation Methods for Real-Time Applications

    DEFF Research Database (Denmark)

    Grest, Daniel; Krüger, Volker; Petersen, Thomas

    2009-01-01

    This work compares iterative 2D-3D Pose Estimation methods for use in real-time applications. The compared methods are available for public as C++ code. One method is part of the openCV library, namely POSIT. Because POSIT is not applicable for planar 3Dpoint congurations, we include the planar P...

  1. Towards Rapid Generation and Visualisation of Large 3D Urban Landscapes for Mobile Device Navigation

    OpenAIRE

    Brujic-Okretic, V.; Gatzidis, C.; Liarokapis, F.; Baker, S.

    2008-01-01

    In this paper a procedural 3D modelling solution for mobile devices is presented based on scripting algorithms allowing for both the automatic and also semi-automatic creation of photorealistic quality virtual urban content. The combination of aerial images, GIS data, 2D ground maps and terrestrial photographs as input data coupled with a user-friendly customized interface permits the automatic and interactive generation of large-scale, accurate, georeferenced and fully-textured 3D virtual ci...

  2. Diffractive centrosymmetric 3D-transmission phase gratings positioned at the image plane of optical systems transform lightlike 4D-WORLD as tunable resonators into spectral metrics...

    Science.gov (United States)

    Lauinger, Norbert

    1999-08-01

    Diffractive 3D phase gratings of spherical scatterers dense in hexagonal packing geometry represent adaptively tunable 4D-spatiotemporal filters with trichromatic resonance in visible spectrum. They are described in the (lambda) - chromatic and the reciprocal (nu) -aspects by reciprocal geometric translations of the lightlike Pythagoras theorem, and by the direction cosine for double cones. The most elementary resonance condition in the lightlike Pythagoras theorem is given by the transformation of the grating constants gx, gy, gz of the hexagonal 3D grating to (lambda) h1h2h3 equals (lambda) 111 with cos (alpha) equals 0.5. Through normalization of the chromaticity in the von Laue-interferences to (lambda) 111, the (nu) (lambda) equals (lambda) h1h2h3/(lambda) 111-factor of phase velocity becomes the crucial resonance factor, the 'regulating device' of the spatiotemporal interaction between 3D grating and light, space and time. In the reciprocal space equal/unequal weights and times in spectral metrics result at positions of interference maxima defined by hyperbolas and circles. A database becomes built up by optical interference for trichromatic image preprocessing, motion detection in vector space, multiple range data analysis, patchwide multiple correlations in the spatial frequency spectrum, etc.

  3. 18 CFR 358.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ...; and natural gas transportation, storage, exchange, backhaul, or displacement service provided pursuant... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Definitions. 358.3 Section 358.3 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT...

  4. 44 CFR 5.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Definitions. 5.3 Section 5.3 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY... means all books, papers, maps, photographs, or other documentary materials, regardless of physical form...

  5. 7 CFR 3016.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Definitions. 3016.3 Section 3016.3 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND COOPERATIVE AGREEMENTS TO STATE AND LOCAL...

  6. 49 CFR 804.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Definitions. 804.3 Section 804.3 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL TRANSPORTATION SAFETY BOARD RULES... problem. Member means an individual duly appointed and confirmed to the collegial body, known as “the...

  7. 40 CFR 174.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Definitions. 174.3 Section 174.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PROCEDURES AND... into the genome of the recipient plant through, for example, micro-injection, macro-injection, micro...

  8. Descriptions of spinal MRI lesions and definition of a positive MRI of the spine in axial spondyloarthritis

    DEFF Research Database (Denmark)

    Hermann, Kay-Geert A; Baraliakos, Xenofon; van der Heijde, Désirée M F M

    2012-01-01

    The aim of this study was to define characteristic MRI findings in the spine of patients with axial spondyloarthritis (SpA) and provide a definition of a positive spinal MRI for inflammation and structural changes.......The aim of this study was to define characteristic MRI findings in the spine of patients with axial spondyloarthritis (SpA) and provide a definition of a positive spinal MRI for inflammation and structural changes....

  9. From 2D to 3D: Using Illumination Cones to Build 3d Face Model

    International Nuclear Information System (INIS)

    Xiao, S S; Jin, M

    2006-01-01

    To solve the problem derivate by lighting condition and position of the camera, a new method using illumination cones to build 3d face model has been proposed. Due to illumination variability, the same object can show dramatic difference even as being viewed in fixed pose. To handle this variability, an object recognition system must employ a representation that is either invariant to, or can model this variability. The proposed technique presents an appearance-based method for modeling the variability due to illumination in the images of objects. The method differs from past appearance-based methods. Evenmore, a small set of training images is used to generate a representation that the illumination cone models the complete set of images of an object with Lambertian reflectance surface under a combination of arbitrary point light sources at infinity. After building up the illumination cones, researches focus on how to present the 3d model of the face. Combining illumination and texture feature to build up 3d model of the face make it easy solving the problem in recognition of face under different pose

  10. Conceptual design of D-3He FRC reactor 'ARTEMIS'

    International Nuclear Information System (INIS)

    Momota, H.; Ishida, A.; Kohzaki, Y.

    1991-07-01

    A comprehensive design study of the D- 3 He fueled field-reversed configuration (FRC) reactor 'ARTEMIS' is carried out for the purpose of proving its attractive characteristics and clarifying the critical issues for a commercial fusion reactor. The FRC burning plasma is stabilized and sustained in a steady equilibrium by means of a preferential trapping of D- 3 He fusion-produced energetic protons. A novel direct energy converter for 15MeV protons is also presented. On the bases of a consistent scenario of the fusion plasma production and simple engineering, a compact and simple reactor concept is presented. The design of the D- 3 He FRC power plant definitely offers the most attractive prospect for energy development. It is environmentally acceptable in view of radio-activity and fuel resources; and the estimated cost of electricity is low compared to a light water reactor. Critical issues concerning physics or engineering for the development of the D- 3 He FRC reactor are clarified. (author)

  11. Dynamical symmetries of semi-linear Schrodinger and diffusion equations

    International Nuclear Information System (INIS)

    Stoimenov, Stoimen; Henkel, Malte

    2005-01-01

    Conditional and Lie symmetries of semi-linear 1D Schrodinger and diffusion equations are studied if the mass (or the diffusion constant) is considered as an additional variable. In this way, dynamical symmetries of semi-linear Schrodinger equations become related to the parabolic and almost-parabolic subalgebras of a three-dimensional conformal Lie algebra (conf 3 ) C . We consider non-hermitian representations and also include a dimensionful coupling constant of the non-linearity. The corresponding representations of the parabolic and almost-parabolic subalgebras of (conf 3 ) C are classified and the complete list of conditionally invariant semi-linear Schrodinger equations is obtained. Possible applications to the dynamical scaling behaviour of phase-ordering kinetics are discussed

  12. METRIC EVALUATION PIPELINE FOR 3D MODELING OF URBAN SCENES

    Directory of Open Access Journals (Sweden)

    M. Bosch

    2017-05-01

    Full Text Available Publicly available benchmark data and metric evaluation approaches have been instrumental in enabling research to advance state of the art methods for remote sensing applications in urban 3D modeling. Most publicly available benchmark datasets have consisted of high resolution airborne imagery and lidar suitable for 3D modeling on a relatively modest scale. To enable research in larger scale 3D mapping, we have recently released a public benchmark dataset with multi-view commercial satellite imagery and metrics to compare 3D point clouds with lidar ground truth. We now define a more complete metric evaluation pipeline developed as publicly available open source software to assess semantically labeled 3D models of complex urban scenes derived from multi-view commercial satellite imagery. Evaluation metrics in our pipeline include horizontal and vertical accuracy and completeness, volumetric completeness and correctness, perceptual quality, and model simplicity. Sources of ground truth include airborne lidar and overhead imagery, and we demonstrate a semi-automated process for producing accurate ground truth shape files to characterize building footprints. We validate our current metric evaluation pipeline using 3D models produced using open source multi-view stereo methods. Data and software is made publicly available to enable further research and planned benchmarking activities.

  13. Metric Evaluation Pipeline for 3d Modeling of Urban Scenes

    Science.gov (United States)

    Bosch, M.; Leichtman, A.; Chilcott, D.; Goldberg, H.; Brown, M.

    2017-05-01

    Publicly available benchmark data and metric evaluation approaches have been instrumental in enabling research to advance state of the art methods for remote sensing applications in urban 3D modeling. Most publicly available benchmark datasets have consisted of high resolution airborne imagery and lidar suitable for 3D modeling on a relatively modest scale. To enable research in larger scale 3D mapping, we have recently released a public benchmark dataset with multi-view commercial satellite imagery and metrics to compare 3D point clouds with lidar ground truth. We now define a more complete metric evaluation pipeline developed as publicly available open source software to assess semantically labeled 3D models of complex urban scenes derived from multi-view commercial satellite imagery. Evaluation metrics in our pipeline include horizontal and vertical accuracy and completeness, volumetric completeness and correctness, perceptual quality, and model simplicity. Sources of ground truth include airborne lidar and overhead imagery, and we demonstrate a semi-automated process for producing accurate ground truth shape files to characterize building footprints. We validate our current metric evaluation pipeline using 3D models produced using open source multi-view stereo methods. Data and software is made publicly available to enable further research and planned benchmarking activities.

  14. Virtual 3d City Modeling: Techniques and Applications

    Science.gov (United States)

    Singh, S. P.; Jain, K.; Mandla, V. R.

    2013-08-01

    3D city model is a digital representation of the Earth's surface and it's related objects such as Building, Tree, Vegetation, and some manmade feature belonging to urban area. There are various terms used for 3D city models such as "Cybertown", "Cybercity", "Virtual City", or "Digital City". 3D city models are basically a computerized or digital model of a city contains the graphic representation of buildings and other objects in 2.5 or 3D. Generally three main Geomatics approach are using for Virtual 3-D City models generation, in first approach, researcher are using Conventional techniques such as Vector Map data, DEM, Aerial images, second approach are based on High resolution satellite images with LASER scanning, In third method, many researcher are using Terrestrial images by using Close Range Photogrammetry with DSM & Texture mapping. We start this paper from the introduction of various Geomatics techniques for 3D City modeling. These techniques divided in to two main categories: one is based on Automation (Automatic, Semi-automatic and Manual methods), and another is Based on Data input techniques (one is Photogrammetry, another is Laser Techniques). After details study of this, finally in short, we are trying to give the conclusions of this study. In the last, we are trying to give the conclusions of this research paper and also giving a short view for justification and analysis, and present trend for 3D City modeling. This paper gives an overview about the Techniques related with "Generation of Virtual 3-D City models using Geomatics Techniques" and the Applications of Virtual 3D City models. Photogrammetry, (Close range, Aerial, Satellite), Lasergrammetry, GPS, or combination of these modern Geomatics techniques play a major role to create a virtual 3-D City model. Each and every techniques and method has some advantages and some drawbacks. Point cloud model is a modern trend for virtual 3-D city model. Photo-realistic, Scalable, Geo-referenced virtual 3

  15. Volumetric 3D display using a DLP projection engine

    Science.gov (United States)

    Geng, Jason

    2012-03-01

    In this article, we describe a volumetric 3D display system based on the high speed DLPTM (Digital Light Processing) projection engine. Existing two-dimensional (2D) flat screen displays often lead to ambiguity and confusion in high-dimensional data/graphics presentation due to lack of true depth cues. Even with the help of powerful 3D rendering software, three-dimensional (3D) objects displayed on a 2D flat screen may still fail to provide spatial relationship or depth information correctly and effectively. Essentially, 2D displays have to rely upon capability of human brain to piece together a 3D representation from 2D images. Despite the impressive mental capability of human visual system, its visual perception is not reliable if certain depth cues are missing. In contrast, volumetric 3D display technologies to be discussed in this article are capable of displaying 3D volumetric images in true 3D space. Each "voxel" on a 3D image (analogous to a pixel in 2D image) locates physically at the spatial position where it is supposed to be, and emits light from that position toward omni-directions to form a real 3D image in 3D space. Such a volumetric 3D display provides both physiological depth cues and psychological depth cues to human visual system to truthfully perceive 3D objects. It yields a realistic spatial representation of 3D objects and simplifies our understanding to the complexity of 3D objects and spatial relationship among them.

  16. Methods for Geometric Data Validation of 3d City Models

    Science.gov (United States)

    Wagner, D.; Alam, N.; Wewetzer, M.; Pries, M.; Coors, V.

    2015-12-01

    Geometric quality of 3D city models is crucial for data analysis and simulation tasks, which are part of modern applications of the data (e.g. potential heating energy consumption of city quarters, solar potential, etc.). Geometric quality in these contexts is however a different concept as it is for 2D maps. In the latter case, aspects such as positional or temporal accuracy and correctness represent typical quality metrics of the data. They are defined in ISO 19157 and should be mentioned as part of the metadata. 3D data has a far wider range of aspects which influence their quality, plus the idea of quality itself is application dependent. Thus, concepts for definition of quality are needed, including methods to validate these definitions. Quality on this sense means internal validation and detection of inconsistent or wrong geometry according to a predefined set of rules. A useful starting point would be to have correct geometry in accordance with ISO 19107. A valid solid should consist of planar faces which touch their neighbours exclusively in defined corner points and edges. No gaps between them are allowed, and the whole feature must be 2-manifold. In this paper, we present methods to validate common geometric requirements for building geometry. Different checks based on several algorithms have been implemented to validate a set of rules derived from the solid definition mentioned above (e.g. water tightness of the solid or planarity of its polygons), as they were developed for the software tool CityDoctor. The method of each check is specified, with a special focus on the discussion of tolerance values where they are necessary. The checks include polygon level checks to validate the correctness of each polygon, i.e. closeness of the bounding linear ring and planarity. On the solid level, which is only validated if the polygons have passed validation, correct polygon orientation is checked, after self-intersections outside of defined corner points and edges

  17. Ontology of a scene based on Java 3D architecture.

    Directory of Open Access Journals (Sweden)

    Rubén González Crespo

    2009-12-01

    Full Text Available The present article seeks to make an approach to the class hierarchy of a scene built with the architecture Java 3D, to develop an ontology of a scene as from the semantic essential components for the semantic structuring of the Web3D. Java was selected because the language recommended by the W3C Consortium for the Development of the Web3D oriented applications as from X3D standard is Xj3D which compositionof their Schemas is based the architecture of Java3D In first instance identifies the domain and scope of the ontology, defining classes and subclasses that comprise from Java3D architecture and the essential elements of a scene, as its point of origin, the field of rotation, translation The limitation of the scene and the definition of shaders, then define the slots that are declared in RDF as a framework for describing the properties of the classes established from identifying thedomain and range of each class, then develops composition of the OWL ontology on SWOOP Finally, be perform instantiations of the ontology building for a Iconosphere object as from class expressions defined.

  18. A harmonic polynomial cell (HPC) method for 3D Laplace equation with application in marine hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yan-Lin, E-mail: yanlin.shao@dnvgl.com; Faltinsen, Odd M.

    2014-10-01

    We propose a new efficient and accurate numerical method based on harmonic polynomials to solve boundary value problems governed by 3D Laplace equation. The computational domain is discretized by overlapping cells. Within each cell, the velocity potential is represented by the linear superposition of a complete set of harmonic polynomials, which are the elementary solutions of Laplace equation. By its definition, the method is named as Harmonic Polynomial Cell (HPC) method. The characteristics of the accuracy and efficiency of the HPC method are demonstrated by studying analytical cases. Comparisons will be made with some other existing boundary element based methods, e.g. Quadratic Boundary Element Method (QBEM) and the Fast Multipole Accelerated QBEM (FMA-QBEM) and a fourth order Finite Difference Method (FDM). To demonstrate the applications of the method, it is applied to some studies relevant for marine hydrodynamics. Sloshing in 3D rectangular tanks, a fully-nonlinear numerical wave tank, fully-nonlinear wave focusing on a semi-circular shoal, and the nonlinear wave diffraction of a bottom-mounted cylinder in regular waves are studied. The comparisons with the experimental results and other numerical results are all in satisfactory agreement, indicating that the present HPC method is a promising method in solving potential-flow problems. The underlying procedure of the HPC method could also be useful in other fields than marine hydrodynamics involved with solving Laplace equation.

  19. Semi-infinite Weil complex and the Virasoro algebra

    International Nuclear Information System (INIS)

    Feigin, B.; Frenkel, E.

    1991-01-01

    We define a semi-infinite analogue of the Weil algebra associated with an infinite-dimensional Lie algebra. It can be used for the definition of semi-infinite characteristic classes by analogy with the Chern-Weil construction. The second term of a spectral sequence of this Weil complex consists of the semi-infinite cohomology of the Lie algebra with coefficients in its 'adjoint semi-infinite symmetric powers'. We compute this cohomology for the Virasoro algebra. This is just the BRST cohomology of the bosonic βγ-system with the central charge 26. We give a complete description of the Fock representations of this bosonic system as modules over the Virasoro algebra, using Friedan-Martinec-Shenker bosonization. We derive a combinatorial identity from this result. (orig.)

  20. 45 CFR 61.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Definitions. 61.3 Section 61.3 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION HEALTHCARE INTEGRITY AND PROTECTION DATA BANK... welfare association, public service group or organization or professional association; and (5) An...

  1. A probabilistic approach using deformable organ models for automatic definition of normal anatomical structures for 3D treatment planning

    International Nuclear Information System (INIS)

    Fritsch, Daniel; Yu Liyun; Johnson, Valen; McAuliffe, Matthew; Pizer, Stephen; Chaney, Edward

    1996-01-01

    Purpose/Objective : Current clinical methods for defining normal anatomical structures on tomographic images are time consuming and subject to intra- and inter-user variability. With the widespread implementation of 3D RTP, conformal radiotherapy, and dose escalation the implications of imprecise object definition have assumed a much higher level of importance. Object definition and volume-weighted metrics for normal anatomy, such as DVHs and NTCPs, play critical roles in aiming, shaping, and weighting beams. Improvements in object definition, including computer automation, are essential to yield reliable volume-weighted metrics and gains in human efficiency. The purpose of this study was to investigate a probabilistic approach using deformable models to automatically recognize and extract normal anatomy in tomographic images. Materials and Methods: Object models were created from normal organs that were segmented by an interactive method which involved placing a cursor near the center of the object on a slice and clicking a mouse button to initiate computation of structures called cores. Cores describe the skeletal and boundary shape of image objects in a manner that, in 2D, associates a location on the skeleton with the width of the object at that location. A significant advantage of cores is stability against image disturbances such as noise and blur. The model was composed of a relatively small set of extracted points on the skeleton and boundary. The points were carefully chosen to summarize the shape information captured by the cores. Neighborhood relationships between points were represented mathematically by energy functions that penalize, due to warping of the model, the ''goodness'' of match between the model and the image data at any stage during the segmentation process. The model was matched against the image data using a probabilistic approach based on Bayes theorem, which provides a means for computing a posteriori (posterior) probability from 1) a

  2. Ideal Positions: 3D Sonography, Medical Visuality, Popular Culture.

    Science.gov (United States)

    Seiber, Tim

    2016-03-01

    As digital technologies are integrated into medical environments, they continue to transform the experience of contemporary health care. Importantly, medicine is increasingly visual. In the history of sonography, visibility has played an important role in accessing fetal bodies for diagnostic and entertainment purposes. With the advent of three-dimensional (3D) rendering, sonography presents the fetus visually as already a child. The aesthetics of this process and the resulting imagery, made possible in digital networks, discloses important changes in the relationship between technology and biology, reproductive health and political debates, and biotechnology and culture.

  3. Human neuron-astrocyte 3D co-culture-based assay for evaluation of neuroprotective compounds.

    Science.gov (United States)

    Terrasso, Ana Paula; Silva, Ana Carina; Filipe, Augusto; Pedroso, Pedro; Ferreira, Ana Lúcia; Alves, Paula Marques; Brito, Catarina

    Central nervous system drug development has registered high attrition rates, mainly due to the lack of efficacy of drug candidates, highlighting the low reliability of the models used in early-stage drug development and the need for new in vitro human cell-based models and assays to accurately identify and validate drug candidates. 3D human cell models can include different tissue cell types and represent the spatiotemporal context of the original tissue (co-cultures), allowing the establishment of biologically-relevant cell-cell and cell-extracellular matrix interactions. Nevertheless, exploitation of these 3D models for neuroprotection assessment has been limited due to the lack of data to validate such 3D co-culture approaches. In this work we combined a 3D human neuron-astrocyte co-culture with a cell viability endpoint for the implementation of a novel in vitro neuroprotection assay, over an oxidative insult. Neuroprotection assay robustness and specificity, and the applicability of Presto Blue, MTT and CytoTox-Glo viability assays to the 3D co-culture were evaluated. Presto Blue was the adequate endpoint as it is non-destructive and is a simpler and reliable assay. Semi-automation of the cell viability endpoint was performed, indicating that the assay setup is amenable to be transferred to automated screening platforms. Finally, the neuroprotection assay setup was applied to a series of 36 test compounds and several candidates with higher neuroprotective effect than the positive control, Idebenone, were identified. The robustness and simplicity of the implemented neuroprotection assay with the cell viability endpoint enables the use of more complex and reliable 3D in vitro cell models to identify and validate drug candidates. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Incomplete factorization technique for positive definite linear systems

    International Nuclear Information System (INIS)

    Manteuffel, T.A.

    1980-01-01

    This paper describes a technique for solving the large sparse symmetric linear systems that arise from the application of finite element methods. The technique combines an incomplete factorization method called the shifted incomplete Cholesky factorization with the method of generalized conjugate gradients. The shifted incomplete Cholesky factorization produces a splitting of the matrix A that is dependent upon a parameter α. It is shown that if A is positive definite, then there is some α for which this splitting is possible and that this splitting is at least as good as the Jacobi splitting. The method is shown to be more efficient on a set of test problems than either direct methods or explicit iteration schemes

  5. 25 CFR 517.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Definitions. 517.3 Section 517.3 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS FREEDOM OF INFORMATION ACT PROCEDURES... research the results of which are not intended to promote any particular product or industry. To qualify...

  6. 21 CFR 514.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... chemical contamination. A manufacturing defect is a product defect caused or aggravated by a manufacturing... inherent to the manufacturing process. These defects are generally associated with product contamination... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Definitions. 514.3 Section 514.3 Food and Drugs...

  7. 24 CFR 70.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Definitions. 70.3 Section 70.3 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development USE OF... of individual volunteers in group insurance plans (such as liability, health, life, disability...

  8. 24 CFR 290.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... multifamily housing project that is not a subsidized project. Useful life means, generally, twenty years, but... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Definitions. 290.3 Section 290.3 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF...

  9. 22 CFR 1414.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    .... (b) The term ex parte communication means an oral or written communication not on the public record... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Definitions. 1414.3 Section 1414.3 Foreign Relations FOREIGN SERVICE LABOR RELATIONS BOARD; FEDERAL LABOR RELATIONS AUTHORITY; GENERAL COUNSEL OF THE...

  10. 7 CFR 784.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Definitions. 784.3 Section 784.3 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE... production. Lambing cycle means the period of time from birth to weaning. Parrot mouth means a genetic defect...

  11. Validation of a 2-D semi-coupled numerical model for fluid-structure-seabed interaction

    Science.gov (United States)

    Ye, Jianhong; Jeng, Dongsheng; Wang, Ren; Zhu, Changqi

    2013-10-01

    A 2-D semi-coupled model PORO-WSSI 2D (also be referred as FSSI-CAS 2D) for the Fluid-Structure-Seabed Interaction (FSSI) has been developed by employing RANS equations for wave motion in fluid domain, VARANS equations for porous flow in porous structures; and taking the dynamic Biot's equations (known as "u - p" approximation) for soil as the governing equations. The finite difference two-step projection method and the forward time difference method are adopted to solve the RANS, VARANS equations; and the finite element method is adopted to solve the "u - p" approximation. A data exchange port is developed to couple the RANS, VARANS equations and the dynamic Biot's equations together. The analytical solution proposed by Hsu and Jeng (1994) and some experiments conducted in wave flume or geotechnical centrifuge in which various waves involved are used to validate the developed semi-coupled numerical model. The sandy bed involved in these experiments is poro-elastic or poro-elastoplastic. The inclusion of the interaction between fluid, marine structures and poro-elastoplastic seabed foundation is a special point and highlight in this paper, which is essentially different with other previous coupled models The excellent agreement between the numerical results and the experiment data indicates that the developed coupled model is highly reliablefor the FSSI problem.

  12. 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Rasch, Helmut; Falkowski, Anna L.; Forrer, Flavio [Kantonsspital Baselland, Institute for Radiology and Nuclear Medicine, Bruderholz (Switzerland); Henckel, Johann [Imperial College London, London (United Kingdom); Hirschmann, Michael T. [Kantonsspital Baselland, Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland)

    2013-09-15

    The purpose was to evaluate the intra- and inter-observer reliability of combined quantitative 3D-volumetric single-photon emission computed tomography (SPECT)/CT analysis including size, intensity and localisation of tracer uptake regions and total knee arthroplasty (TKA) position. Tc-99m-HDP-SPECT/CT of 100 knees after TKA were prospectively analysed. The anatomical areas represented by a previously validated localisation scheme were 3D-volumetrically analysed. The maximum intensity was recorded for each anatomical area. Ratios between the respective value and the mid-shaft of the femur as the reference were calculated. Femoral and tibial TKA position (varus-valgus, flexion-extension, internal rotation- external rotation) were determined on 3D-CT. Two consultant radiologists/nuclear medicine physicians interpreted the SPECT/CTs twice with a 2-week interval. The inter- and intra-observer reliability was determined (ICCs). Kappa values were calculated for the area with the highest tracer uptake between the observers. The measurements of tracer uptake intensity showed excellent inter- and intra-observer reliabilities for all regions (tibia, femur and patella). Only the tibial shaft area showed ICCs <0.89. The kappa values were almost perfect (0.856, p < 0.001; 95 % CI 0.778, 0.922). For measurements of the TKA position, there was strong agreement within and between the readings of the two observers; the ICCs for the orientation of TKA components for inter- and intra-observer reliability were nearly perfect (ICCs >0.84). This combined 3D-volumetric standardised method of analysing the location, size and the intensity of SPECT/CT tracer uptake regions (''hotspots'') and the determination of the TKA position was highly reliable and represents a novel promising approach to biomechanics. (orig.)

  13. 36 CFR 1193.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... TELECOMMUNICATIONS ACT ACCESSIBILITY GUIDELINES General § 1193.3 Definitions. Terms used in this part shall have the... deaf persons) or computers with special modems. TTYs are also called text telephones. Usable. Means...

  14. 3D High-definition anorectal manometry: Values obtained in asymptomatic volunteers, fecal incontinence and chronic constipation. Results of a prospective multicenter study (NOMAD).

    Science.gov (United States)

    Mion, F; Garros, A; Brochard, C; Vitton, V; Ropert, A; Bouvier, M; Damon, H; Siproudhis, L; Roman, S

    2017-08-01

    3D-high definition anorectal manometry (3DARM) may aid the diagnosis of functional anorectal disorders, but data comparing asymptomatic and symptomatic subjects are scarce. We aimed to describe 3DARM values in asymptomatic volunteers and those with fecal incontinence (FI) or chronic constipation (CC), and identify which variables differentiate best these groups. Asymptomatic subjects were stratified by sex, age, and parity. Those with FI or CC were included according to anorectal symptom questionnaires. Endoanal ultrasound examination and 3DARM were performed the same day. Anal pressures were analyzed at rest, during voluntary squeeze, and during push maneuver, and compared between the 3 groups. Anal pressure defects were defined and compared to ultrasound defects. A total of 126 subjects (113 female, mean age 52 years, range 18-83) were included; 36 asymptomatic, 38 FI, 42 CC. Anal resting and squeeze pressures, and rectal sensitivity values were lower in FI women than in the other groups. Typical anal sphincter asymmetry during squeezing was less frequently observed in FI women. A dyssynergic pattern during push maneuver was found in 70% of asymptomatic subjects, and with a similar frequency in the 2 symptomatic groups. There was slight concordance between 3D-pressure defects and ultrasound defects. 3D anal pressures in asymptomatic women were significantly lower than in men, and in FI compared to asymptomatic women. The classical dyssynergic pattern during push maneuver was found as frequently in asymptomatic and symptomatic patients. Further studies should try to identify 3DARM variables that could reliably identify dyssynergic defecation. © 2017 John Wiley & Sons Ltd.

  15. 3D roadmap in neuroangiography: technique and clinical interest

    International Nuclear Information System (INIS)

    Soederman, Michael; Andersson, T.; Babic, D.; Homan, R.

    2005-01-01

    We present the first clinical results obtained with a novel technique: the three-dimensional [3D] roadmap. The major difference from the standard 2D digital roadmap technique is that the newly developed 3D roadmap is based on a rotational angiography acquisition technique with the two-dimensional [2D] fluoroscopic image as an overlay. Data required for an accurate superimposition of the previously acquired 3D reconstructed image on the interactively made 2D fluoroscopy image, in real time, are stored in the 3D workstation and constitute the calibration dataset. Both datasets are spatially aligned in real time; thus, the 3D image is accurately superimposed on the 2D fluoroscopic image regardless of any change in C-arm position or magnification. The principal advantage of the described roadmap method is that one contrast injection allows the C-arm to be positioned anywhere in the space and allows alterations in the distance between the x-ray tube and the image intensifier as well as changes in image magnification. In the clinical setting, the 3D roadmap facilitated intravascular neuronavigation with concurrent reduction of procedure time and use of contrast medium. (orig.)

  16. 40 CFR 113.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... Pollution Contingency Plan and identified in approved Regional Oil and Hazardous Substances Pollution Contingency Plans. (h) Oil means oil of any kind or in any form, including but not limited to, petroleum, fuel... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Definitions. 113.3 Section 113.3...

  17. 40 CFR 305.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... Pennsylvania Ave., NW., Washington, DC 20460. National Contingency Plan or NCP means the National Oil and Hazardous Substances Pollution Contingency Plan developed under section 311(c) of the Clean Water Act and... 40 Protection of Environment 27 2010-07-01 2010-07-01 false Definitions. 305.3 Section 305.3...

  18. 21 CFR 114.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Definitions. 114.3 Section 114.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN..., “pickles” or “pickled ___.” Carbonated beverages, jams, jellies, preserves, acid foods (including such...

  19. 28 CFR 93.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Definitions. 93.3 Section 93.3 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PROVISIONS IMPLEMENTING THE VIOLENT CRIME CONTROL AND LAW... 901(a)(2) of the Omnibus Crime Control and Safe Streets Act of 1968, as amended. (b) Unit of Local...

  20. 21 CFR 328.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Definitions. 328.3 Section 328.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE OVER-THE-COUNTER DRUG PRODUCTS INTENDED FOR ORAL INGESTION THAT CONTAIN ALCOHOL General Provisions...

  1. 21 CFR 352.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ...) and desired response to ultraviolet (UV) radiation. (1) Minimal sun protection product. A sunscreen... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Definitions. 352.3 Section 352.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE...

  2. 36 CFR 297.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 297.3 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF AGRICULTURE WILD AND SCENIC RIVERS Water Resources Projects § 297.3 Definitions. Act means the Wild and Scenic Rivers Act (82 Stat... assistance affecting the free-flowing characteristics or the scenic or natural values of a Wild and Scenic...

  3. Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology

    DEFF Research Database (Denmark)

    Engelen, Arna van; Niessen, Wiro J.; Klein, Stefan

    2012-01-01

    . The ground truth for fibrous, necrotic and calcified tissue was provided by histology and micro-CT in 12 carotid plaque specimens. Semi-automatic registration of a 3D stack of histological slices and micro-CT images to MRI allowed for 3D rotations and inplane deformations of histology. By basing voxelwise...

  4. 32 CFR 235.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... SALE OR RENTAL OF SEXUALLY EXPLICIT MATERIAL ON DOD PROPERTY § 235.3 Definitions. For the purpose of... power, influence, and importance to all other themes in the material combined. Lascivious. Lewd and...

  5. 45 CFR 1321.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... PROGRAMS ON AGING Introduction § 1321.3 Definitions. Act means the Older Americans Act of 1965 as amended... a new facility, including the costs of land acquisition and architectural and engineering fees, or...

  6. 32 CFR 272.3 - Definition of basic research.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Definition of basic research. 272.3 Section 272...) MISCELLANEOUS ADMINISTRATION AND SUPPORT OF BASIC RESEARCH BY THE DEPARTMENT OF DEFENSE § 272.3 Definition of... increasing fundamental knowledge and understanding in those fields of the physical, engineering...

  7. A 3D T1-weighted gradient-echo sequence for routine use in 3D radiosurgical treatment planning of brain metastases: first clinical results

    International Nuclear Information System (INIS)

    Hawighorst, H.; Schad, L.R.; Gademann, G.; Knopp, M.V.; Wenz, F.; Kaick, G. van

    1995-01-01

    The authors report on a 3D sequence for MRI of the brain and its application in radiosurgical treatment planning of 35 brain metastases. The measuring sequence, called magnetization - prepared rapid gradient echo (MPRAGE), was compared with 2D T1-weighted spin-echo (SE) sequences following intravenous contrast-medium application in 19 patients with brain metastases. The average diameter of all lesions was similar in both sequences, with 16.8 and 17.0 mm for SE and MPRAGE, respectively. Target point definition was equal in 29 metastases, and in 6 cases superior on MPRAGE, due to better gray-white matter contrast and increased contrast enhancement. In cases of bleeding metastases there was improved depiction of internal structures in 3D MRI. Postprocessing of 3D MPRAGE data created multiplanar reconstruction along any chosen plane with isotropic spatial resolution, which helped to improve radiosurgical isodose distribution in 4 cases when compared to 2D SE. However, sensitivity of 3D MPRAGE to detect small lesions (< 3 mm) was decreased in one patient with more than 50 metastases. We conclude that 3D gradient-echo (GE) imaging might be of great value for radiosurgical treatment planning, but does not replace 2D SE with its current parameters. (orig.)

  8. Semi-empirical neutron tool calibration (one and two-group approximation)

    International Nuclear Information System (INIS)

    Czubek, J.A.

    1988-01-01

    The physical principles of the new method of calibration of neutron tools for the rock porosity determination are given. A short description of the physics of neutron transport in the matter is presented together with some remarks on the elementary interactions of neutrons with nuclei (cross sections, group cross sections etc.). The definitions of the main integral parameters characterizing the neutron transport in the rock media are given. The three main approaches to the calibration problem: empirical, theoretical and semi-empirical are presented with some more detailed description of the latter one. The new semi-empirical approach is described. The method is based on the definition of the apparent slowing down or migration length for neutrons sensed by the neutron tool situated in the real borehole-rock conditions. To calculate this apparent slowing down or migration lengths the ratio of the proper space moments of the neutron distribution along the borehole axis is used. Theoretical results are given for one- and two-group diffusion approximations in the rock-borehole geometrical conditions when the tool is in the sidewall position. The physical and chemical parameters are given for the calibration blocks of the Logging Company in Zielona Gora. Using these data the neutron parameters of the calibration blocks have been calculated. An example, how to determine the calibration curve for the dual detector tool applying this new method and using the neutron parameters mentioned above together with the measurements performed in the calibration blocks, is given. The most important advantage of the new semi-empirical method of calibration is the possibility of setting on the unique calibration curve all experimental calibration data obtained for a given neutron tool for different porosities, lithologies and borehole diameters. 52 refs., 21 figs., 21 tabs. (author)

  9. 3D-printed orthodontic brackets - proof of concept.

    Science.gov (United States)

    Krey, Karl-Friedrich; Darkazanly, Nawras; Kühnert, Rolf; Ruge, Sebastian

    Today, orthodontic treatment with fixed appliances is usually carried out using preprogrammed straight-wire brackets made of metal or ceramics. The goal of this study was to determine the possibility of clinically implementing a fully digital workflow with individually designed and three-dimensionally printed (3D-printed) brackets. Edgewise brackets were designed using computer-aided design (CAD) software for demonstration purposes. After segmentation of the malocclusion model generated based on intraoral scan data, the brackets were digitally positioned on the teeth and a target occlusion model created. The thus-defined tooth position was used to generate a template for an individualized arch form in the horizontal plane. The base contours of the brackets were modified to match the shape of the tooth surfaces, and a positioning guide (fabricated beforehand) was used to ensure that the brackets were bonded at the correct angle and position. The brackets, positioning guide, and retainer splint, digitally designed on the target occlusion model, were 3D printed using a Digital Light Processing (DLP) 3D printer. The archwires were individually pre-bent using the template. In the treatment sequence, it was shown for the first time that, in principle, it is possible to perform treatment with an individualized 3D-printed brackets system by using the proposed fully digital workflow. Technical aspects of the system, problems encountered in treatment, and possible future developments are discussed in this article.

  10. Semi-classical analysis of scattering of deformed heavy-ions below the Coulomb barrier

    International Nuclear Information System (INIS)

    Johnson, R.C.; Roberts, E.J.; Sukumar, C.V.; Brink, D.M.

    1995-01-01

    Polarization observables for the sub-Coulomb elastic scattering of a quadrupole deformed projectile of spin 3/2 from a spinless spherical target are evaluated using a new semi-classical method based on a path-integral formalism. Analytic expressions are obtained which agree well with coupled channels calculations and which predict definite deviations from the ''shape-effect'' relations for tensor analyzing powers

  11. Evaluation of semi-automatic arterial stenosis quantification

    International Nuclear Information System (INIS)

    Hernandez Hoyos, M.; Universite Claude Bernard Lyon 1, 69 - Villeurbanne; Univ. de los Andes, Bogota; Serfaty, J.M.; Douek, P.C.; Universite Claude Bernard Lyon 1, 69 - Villeurbanne; Hopital Cardiovasculaire et Pneumologique L. Pradel, Bron; Maghiar, A.; Mansard, C.; Orkisz, M.; Magnin, I.; Universite Claude Bernard Lyon 1, 69 - Villeurbanne

    2006-01-01

    Object: To assess the accuracy and reproducibility of semi-automatic vessel axis extraction and stenosis quantification in 3D contrast-enhanced Magnetic Resonance Angiography (CE-MRA) of the carotid arteries (CA). Materials and methods: A total of 25 MRA datasets was used: 5 phantoms with known stenoses, and 20 patients (40 CAs) drawn from a multicenter trial database. Maracas software extracted vessel centerlines and quantified the stenoses, based on boundary detection in planes perpendicular to the centerline. Centerline accuracy was visually scored. Semi-automatic measurements were compared with: (1) theoretical phantom morphometric values, and (2) stenosis degrees evaluated by two independent radiologists. Results: Exploitable centerlines were obtained in 97% of CA and in all phantoms. In phantoms, the software achieved a better agreement with theoretic stenosis degrees (weighted kappa Κ W = 0.91) than the radiologists (Κ W = 0.69). In patients, agreement between software and radiologists varied from Κ W =0.67 to 0.90. In both, Maracas was substantially more reproducible than the readers. Mean operating time was within 1 min/ CA. Conclusion: Maracas software generates accurate 3D centerlines of vascular segments with minimum user intervention. Semi-automatic quantification of CA stenosis is also accurate, except in very severe stenoses that cannot be segmented. It substantially reduces the inter-observer variability. (orig.)

  12. D3D augmented reality imaging system: proof of concept in mammography

    Directory of Open Access Journals (Sweden)

    Douglas DB

    2016-08-01

    Full Text Available David B Douglas,1 Emanuel F Petricoin,2 Lance Liotta,2 Eugene Wilson3 1Department of Radiology, Stanford University, Palo Alto, CA, 2Center for Applied Proteomics and Molecular Medicine, George Mason University, Manassas, VA, 3Department of Radiology, Fort Benning, Columbus, GA, USA Purpose: The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called “depth 3-dimensional (D3D augmented reality”. Materials and methods: A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. Results: The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. Conclusion: The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice. Keywords: augmented reality, 3D medical imaging, radiology, depth perception

  13. Cost-benefit analysis of 3D conformal radiation therapy. Treatment of prostate cancer as a model

    International Nuclear Information System (INIS)

    Cho, K.H.; Khan, F.M.; Levitt, S.H.

    1999-01-01

    Three-dimensional conformal radiation therapy (3D-CRT) is a promising new treatment technique based on the principle that improved precision in both tumor definition and dose delivery will enhance outcomes by maximizing dose to the tumor area while minimizing dose to normal tissue. Using a cost-benefit analysis, in terms of outcomes, we first examined the overall risks and benefits of 3D-CRT. We then used the treatment of prostate cancer as a model to compare actual clinical outcomes reported between 3D-CRT and standard radiation therapy (SRT). Our analysis shows that application of 3D-CRT to the clinical setting remains difficult because of the continual difficulties of target definition, and that dose escalation cannot yet be justified on the basis of the lack of benefit found, and suggested increased late toxicity, in most of the dose escalation series compared with SRT. (orig.)

  14. Combining Semi-Endogenous and Fully Endogenous Growth: a Generalization.

    OpenAIRE

    Cozzi, Guido

    2017-01-01

    This paper shows that combining the semi-endogenous and the fully endogenous growth mechanisms with a general CES aggregator, either growth process can prevail in the balanced growth path depending on their degree of complementarity/substitutability. Policy-induced long-run economic switches to the fully endogenous steady state as the R&D employment ratio surpasses a positive threshold are possible if the two growth engines are gross substitutes.

  15. Rendering Large-Scale Terrain Models and Positioning Objects in Relation to 3D Terrain

    National Research Council Canada - National Science Library

    Hittner, Brian

    2003-01-01

    .... Rendering large scale landscapes based on 3D geometry generally did not occur because the scenes generated tended to use up too much system memory and overburden 3D graphics cards with too many polygons...

  16. Sensitivity analysis and optimization algorithms for 3D forging process design

    International Nuclear Information System (INIS)

    Do, T.T.; Fourment, L.; Laroussi, M.

    2004-01-01

    This paper presents several approaches for preform shape optimization in 3D forging. The process simulation is carried out using the FORGE3 registered finite element software, and the optimization problem regards the shape of initial axisymmetrical preforms. Several objective functions are considered, like the forging energy, the forging force or a surface defect criterion. Both deterministic and stochastic optimization algorithms are tested for 3D applications. The deterministic approach uses the sensitivity analysis that provides the gradient of the objective function. It is obtained by the adjoint-state method and semi-analytical differentiation. The study of stochastic approaches aims at comparing genetic algorithms and evolution strategies. Numerical results show the feasibility of such approaches, i.e. the achieving of satisfactory solutions within a limited number of 3D simulations, less than fifty. For a more industrial problem, the forging of a gear, encouraging optimization results are obtained

  17. [Research progress of Lgr5-positive stem cells in the formation of organoid in 3D culture].

    Science.gov (United States)

    He, Q Q; Li, A; Wang, M H; Gao, X

    2018-06-07

    Stem cell is critical to regeneration of tissue or organ of human. How to promote repair or regeneration in the tissues/organ using its pluripotency is always an important issue. Lgr5-possitive cell is one type of the stem cell-like cells capable of pluripotent differentiation in various tissues/organs of both humans and mice. Current study showed that single or small amount Lgr5-possitive stem cells can grow and form a plurality of organs in 3D culture system, and some organs can present similar biological and physiological properties with the progenitor they were derived. These studies provided new insight into future orientation, for example, Lgr5-possitive inner ear cells were confirmed as inner ear pluripotent cells population, the experiences obtained from organoid studies of Lgr5-possitive cells have certainly showed potential in the future study of inner ear stem cells. This review will focus on the recent progress associated with Lgr 5-positive stem cells forming organoids in the 3D culture.

  18. 3D Reflection Map Modeling for Optical Emitter-receiver Pairs

    DEFF Research Database (Denmark)

    Christensen, Henrik Vie

    2004-01-01

    A model for a model-based 3D-position determination system for a passive object is presented. Infrared emitter/receiver pairs are proposed as sensing part to acquire information on a ball shaped object's position. A 3D reflection map model is derived trough geometrical considerations. The model...

  19. 10 CFR 715.3 - Definition of “Nonrecourse Project-Financed”.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Definition of âNonrecourse Project-Financedâ. 715.3 Section 715.3 Energy DEPARTMENT OF ENERGY DEFINITION OF NON-RECOURSE PROJECT-FINANCED § 715.3 Definition... disqualify a facility from being “nonrecourse project-financed” as long as, at the time of the financing for...

  20. 3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation

    International Nuclear Information System (INIS)

    Frericks, Bernd B.; Caldarone, Franco C.; Savellano, Dagmar Hoegemann; Stamm, Georg; Kirchhoff, Timm D.; Shin, Hoen-Oh; Galanski, Michael; Nashan, Bjoern; Klempnauer, Juergen; Schenk, Andrea; Selle, Dirk; Spindler, Wolf; Peitgen, Heinz-Otto

    2004-01-01

    The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110±180 ml for right lobes, 820 ml for the left lobe and 270±30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments. (orig.)

  1. Maximum margin semi-supervised learning with irrelevant data.

    Science.gov (United States)

    Yang, Haiqin; Huang, Kaizhu; King, Irwin; Lyu, Michael R

    2015-10-01

    Semi-supervised learning (SSL) is a typical learning paradigms training a model from both labeled and unlabeled data. The traditional SSL models usually assume unlabeled data are relevant to the labeled data, i.e., following the same distributions of the targeted labeled data. In this paper, we address a different, yet formidable scenario in semi-supervised classification, where the unlabeled data may contain irrelevant data to the labeled data. To tackle this problem, we develop a maximum margin model, named tri-class support vector machine (3C-SVM), to utilize the available training data, while seeking a hyperplane for separating the targeted data well. Our 3C-SVM exhibits several characteristics and advantages. First, it does not need any prior knowledge and explicit assumption on the data relatedness. On the contrary, it can relieve the effect of irrelevant unlabeled data based on the logistic principle and maximum entropy principle. That is, 3C-SVM approaches an ideal classifier. This classifier relies heavily on labeled data and is confident on the relevant data lying far away from the decision hyperplane, while maximally ignoring the irrelevant data, which are hardly distinguished. Second, theoretical analysis is provided to prove that in what condition, the irrelevant data can help to seek the hyperplane. Third, 3C-SVM is a generalized model that unifies several popular maximum margin models, including standard SVMs, Semi-supervised SVMs (S(3)VMs), and SVMs learned from the universum (U-SVMs) as its special cases. More importantly, we deploy a concave-convex produce to solve the proposed 3C-SVM, transforming the original mixed integer programming, to a semi-definite programming relaxation, and finally to a sequence of quadratic programming subproblems, which yields the same worst case time complexity as that of S(3)VMs. Finally, we demonstrate the effectiveness and efficiency of our proposed 3C-SVM through systematical experimental comparisons. Copyright

  2. Soft tissue segmentation and 3D display from computerized tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Fan, R.T.; Trivedi, S.S.; Fellingham, L.L.; Gamboa-Aldeco, A.; Hedgcock, M.W.

    1987-01-01

    Volume calculation and 3D display of human anatomy facilitate a physician's diagnosis, treatment, and evaluation. Accurate segmentation of soft tissue structures is a prerequisite for such volume calculations and 3D displays, but segmentation by hand-outlining structures is often tedious and time-consuming. In this paper, methods based on analysis of statistics of image gray level are applied to segmentation of soft tissue in medical images, with the goal of making segmentation automatic or semi-automatic. The resulting segmented images, volume calculations, and 3D displays are analyzed and compared with results based on physician-drawn outlines as well as actual volume measurements

  3. Simion 3D Version 6.0 User`s Manual

    Energy Technology Data Exchange (ETDEWEB)

    Dahl, D.A.

    1995-11-01

    The original SIMION was an electrostatic lens analysis and design program developed by D.C. McGilvery at Latrobe University, Bundoora Victoria, Australia, 1977. SIMION for the PC, developed at the Idaho National Engineering Laboratory, shares little more than its name with the original McGilvery version. INEL`s fifth major SIMION release, version 6.0, represents a quantum improvement over previous versions. This C based program can model complex problems using an ion optics workbench that can hold up to 200 2D and/or 3D electrostatic/magnetic potential arrays. Arrays can have up to 10,000,000 points. SIMION 3D`s 32 bit virtual Graphics User Interface provides a highly interactive advanced user environment. All potential arrays are visualized as 3D objects that the user can cut away to inspect ion trajectories and potential energy surfaces. User programs have been greatly extended in versatility and power. A new geometry file option supports the definition of highly complex array geometry. Extensive algorithm modifications have dramatically improved this version`s computational speed and accuracy.

  4. 21 CFR 21.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Definitions. 21.3 Section 21.3 Food and Drugs FOOD... products regulated by the Food and Drug Administration or with which the Food and Drug Administration has business dealings. Any such business enterprise that is identified by the name of one or more individuals...

  5. 21 CFR 82.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Definitions. 82.3 Section 82.3 Food and Drugs FOOD... gloss white means a suspension in water of co-precipitated aluminum hydroxide and barium sulfate. (j... interpretations of terms contained in section 201 of the Federal Food, Drug, and Cosmetic Act shall be applicable...

  6. SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Yong [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Lee, So-Yeon [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Yang-Soo [The Catholic University of Korea, Department of Orthopaedic Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of)

    2013-02-15

    The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar's test, and inter-observer agreement was calculated using Cohen's kappa. Receiver operating characteristic (ROC) curve analyses were performed. The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE ({kappa} = 0.76) and 3D TSE-SPACE ({kappa} = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions circle MR arthrography is regarded as the definitive method of shoulder imaging circle Different MR sequences are evolving for SLAP lesions circle 3D TSE-SPACE demonstrated comparable overall accuracy to 2D TSE for SLAP lesions. (orig.)

  7. 45 CFR 1326.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... SUPPORT AND NUTRITION SERVICES § 1326.3 Definitions. Acquiring, as used in section 307(a)(14) of the Act... support, including any extensions. Service area, as used in § 1326.9(b) and elsewhere in this part, means...

  8. Cross-cultural comparison of successful aging definitions between Chinese and Hmong elders in the United States.

    Science.gov (United States)

    Nguyen, Annie L; Seal, David W

    2014-06-01

    The purpose of the study was to elicit the definitions of successful aging according to Chinese and Hmong elders living in Milwaukee, WI. In-depth semi-structured interviews were conducted with 44 elders (Hmong n = 21 and Chinese n = 23). Findings show some similarities in the Chinese and Hmong elders' definitions though specific cultural differences exist. Chinese elders emphasized physical health and mobility, mental health, positive attitudes, shedding responsibilities, positive family relationships, financial stability, social engagement, religious faith, and accomplishments and volunteer work. Hmong elders emphasized physical health and mobility, mental health, harmonious relationships, positive family relationships, tangible family support, financial stability, social engagement, and religious faith. Cross-cultural comparisons of the findings highlight the cultural heterogeneity between these two subgroups. Implications for practice are discussed.

  9. Development of a 3D consistent 1D neutronics model for reactor core simulation

    International Nuclear Information System (INIS)

    Lee, Ki Bog; Joo, Han Gyu; Cho, Byung Oh; Zee, Sung Quun

    2001-02-01

    In this report a 3D consistent 1D model based on nonlinear analytic nodal method is developed to reproduce the 3D results. During the derivation, the current conservation factor (CCF) is introduced which guarantees the same axial neutron currents obtained from the 1D equation as the 3D reference values. Furthermore in order to properly use 1D group constants, a new 1D group constants representation scheme employing tables for the fuel temperature, moderator density and boron concentration is developed and functionalized for the control rod tip position. To test the 1D kinetics model with CCF, several steady state and transient calculations were performed and compared with 3D reference values. The errors of K-eff values were reduced about one tenth when using CCF without significant computational overhead. And the errors of power distribution were decreased to the range of one fifth or tenth at steady state calculation. The 1D kinetics model with CCF and the 1D group constant functionalization employing tables as a function of control rod tip position can provide preciser results at the steady state and transient calculation. Thus it is expected that the 1D kinetics model derived in this report can be used in the safety analysis, reactor real time simulation coupled with system analysis code, operator support system etc.

  10. 3D Virtual Dig: a 3D Application for Teaching Fieldwork in Archaeology

    Directory of Open Access Journals (Sweden)

    Paola Di Giuseppantonio Di Franco

    2012-12-01

    Full Text Available Archaeology is a material, embodied discipline; communicating this experience is critical to student success. In the context of lower-division archaeology courses, the present study examines the efficacy of 3D virtual and 2D archaeological representations of digs. This presentation aims to show a 3D application created to teach the archaeological excavation process to freshmen students. An archaeological environment was virtually re-created in 3D, and inserted in a virtual reality software application that allows users to work with the reconstructed excavation area. The software was tested in class for teaching the basics of archaeological fieldwork. The application interface is user-friendly and especially easy for 21st century students. The study employed a pre-survey, post-test, and post-survey design, used to understand the students' previous familiarity with archaeology, and test their awareness after the use of the application. Their level of knowledge was then compared with that of those students who had accessed written material only. This case-study demonstrates how a digital approach to laboratory work can positively affect student learning. Increased abilities to complete ill-defined problems (characteristic of the high-order thinking in the field, can, in fact, be demonstrated. 3D Virtual reconstruction serves, then, as an important bridge from traditional coursework to fieldwork.

  11. Computer Vision Tracking Using Particle Filters for 3D Position Estimation

    Science.gov (United States)

    2014-03-27

    List of Acronyms Acronym Definition AFIT Air Force Institute of Technology ASIR Auxiliary Sampling Importance Re-sampling BPF Bootstrap Particle Filter...Auxiliary Sampling Importance Re-sampling ( ASIR ) filter, and Regularized Particle Filter (RPF), also seek to eliminate weight collapse through a variety

  12. Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

    Science.gov (United States)

    Ono, Tomohiro; Nakamura, Mitsuhiro; Hirose, Yoshinori; Kitsuda, Kenji; Ono, Yuka; Ishigaki, Takashi; Hiraoka, Masahiro

    2017-09-01

    To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  13. The capture and recreation of 3D auditory scenes

    Science.gov (United States)

    Li, Zhiyun

    The main goal of this research is to develop the theory and implement practical tools (in both software and hardware) for the capture and recreation of 3D auditory scenes. Our research is expected to have applications in virtual reality, telepresence, film, music, video games, auditory user interfaces, and sound-based surveillance. The first part of our research is concerned with sound capture via a spherical microphone array. The advantage of this array is that it can be steered into any 3D directions digitally with the same beampattern. We develop design methodologies to achieve flexible microphone layouts, optimal beampattern approximation and robustness constraint. We also design novel hemispherical and circular microphone array layouts for more spatially constrained auditory scenes. Using the captured audio, we then propose a unified and simple approach for recreating them by exploring the reciprocity principle that is satisfied between the two processes. Our approach makes the system easy to build, and practical. Using this approach, we can capture the 3D sound field by a spherical microphone array and recreate it using a spherical loudspeaker array, and ensure that the recreated sound field matches the recorded field up to a high order of spherical harmonics. For some regular or semi-regular microphone layouts, we design an efficient parallel implementation of the multi-directional spherical beamformer by using the rotational symmetries of the beampattern and of the spherical microphone array. This can be implemented in either software or hardware and easily adapted for other regular or semi-regular layouts of microphones. In addition, we extend this approach for headphone-based system. Design examples and simulation results are presented to verify our algorithms. Prototypes are built and tested in real-world auditory scenes.

  14. GammaModeler 3-D gamma-ray imaging technology

    International Nuclear Information System (INIS)

    2000-01-01

    The 3-D GammaModelertrademark system was used to survey a portion of the facility and provide 3-D visual and radiation representation of contaminated equipment located within the facility. The 3-D GammaModelertrademark system software was used to deconvolve extended sources into a series of point sources, locate the positions of these sources in space and calculate the 30 cm. dose rates for each of these sources. Localization of the sources in three dimensions provides information on source locations interior to the visual objects and provides a better estimate of the source intensities. The three dimensional representation of the objects can be made transparent in order to visualize sources located within the objects. Positional knowledge of all the sources can be used to calculate a map of the radiation in the canyon. The use of 3-D visual and gamma ray information supports improved planning decision-making, and aids in communications with regulators and stakeholders

  15. 32 CFR 85.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... § 85.3 Definitions. Health Promotion. Any combination of health education and related organizational... alterations that will improve or protect health. It includes those activities intended to support and..., health promotion includes smoking prevention and cessation, physical fitness, nutrition, stress...

  16. 32 CFR 162.3 - Definition.

    Science.gov (United States)

    2010-07-01

    ... Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DEFENSE CONTRACTING PRODUCTIVITY ENHANCING CAPITAL INVESTMENT (PECI) § 162.3 Definition. (a) Capital Investment. The acquisition, installation, transportation... timeliness. (l) Productivity Enhancing Capital Investment (PECI). Equipment or facility funding that shall...

  17. On entanglement entropy in non-Abelian lattice gauge theory and 3D quantum gravity

    Energy Technology Data Exchange (ETDEWEB)

    Delcamp, Clement [Perimeter Institute for Theoretical Physics,31 Caroline Street North, Waterloo, Ontario N2L 2Y5 (Canada); Department of Physics & Astronomy and Guelph-Waterloo Physics Institute, University of Waterloo,200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Dittrich, Bianca; Riello, Aldo [Perimeter Institute for Theoretical Physics,31 Caroline Street North, Waterloo, Ontario N2L 2Y5 (Canada)

    2016-11-18

    Entanglement entropy is a valuable tool for characterizing the correlation structure of quantum field theories. When applied to gauge theories, subtleties arise which prevent the factorization of the Hilbert space underlying the notion of entanglement entropy. Borrowing techniques from extended topological field theories, we introduce a new definition of entanglement entropy for both Abelian and non-Abelian gauge theories. Being based on the notion of excitations, it provides a completely relational way of defining regions. Therefore, it naturally applies to background independent theories, e.g. gravity, by circumventing the difficulty of specifying the position of the entangling surface. We relate our construction to earlier proposals and argue that it brings these closer to each other. In particular, it yields the non-Abelian analogue of the ‘magnetic centre choice’, as obtained through an extended-Hilbert-space method, but applied to the recently introduced fusion basis for 3D lattice gauge theories. We point out that the different definitions of entanglement entropy can be related to a choice of (squeezed) vacuum state.

  18. Positive-definite functions and unitary representations of locally compact groups in a Hilbert space

    International Nuclear Information System (INIS)

    Gali, I.M.; Okb el-Bab, A.S.; Hassan, H.M.

    1977-08-01

    It is proved that the necessary and sufficient condition for the existence of an integral representation of a group of unitary operators in a Hilbert space is that it is positive-definite and continuous in some topology

  19. Simultaneous 3D localization of multiple MR-visible markers in fully reconstructed MR images: proof-of-concept for subsecond position tracking.

    Science.gov (United States)

    Thörmer, Gregor; Garnov, Nikita; Moche, Michael; Haase, Jürgen; Kahn, Thomas; Busse, Harald

    2012-04-01

    To determine whether a greatly reduced spatial resolution of fully reconstructed projection MR images can be used for the simultaneous 3D localization of multiple MR-visible markers and to assess the feasibility of a subsecond position tracking for clinical purposes. Miniature, inductively coupled RF coils were imaged in three orthogonal planes with a balanced steady-state free precession (SSFP) sequence and automatically localized using a two-dimensional template fitting and a subsequent three-dimensional (3D) matching of the coordinates. Precision, accuracy, speed and robustness of 3D localization were assessed for decreasing in-plane resolutions (0.6-4.7 mm). The feasibility of marker tracking was evaluated at the lowest resolution by following a robotically driven needle on a complex 3D trajectory. Average 3D precision and accuracy, sensitivity and specificity of localization ranged between 0.1 and 0.4 mm, 0.5 and 1.0 mm, 100% and 95%, and 100% and 96%, respectively. At the lowest resolution, imaging and localization took ≈350 ms and provided an accuracy of ≈1.0 mm. In the tracking experiment, the needle was clearly depicted on the oblique scan planes defined by the markers. Image-based marker localization at a greatly reduced spatial resolution is considered a feasible approach to monitor reference points or rigid instruments at subsecond update rates. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Automatic detection of patient position for incorporation in exact 3D reconstruction for emission tomography

    International Nuclear Information System (INIS)

    Kyme, A.; Hutton, B.; Hatton, R.; Skerrett, D.

    2000-01-01

    Full text: SPECT involves acquiring a set of projection images using one or more rotating gamma cameras. The projections are then reconstructed to create transverse slices. Patient motion during the scan can introduce inconsistencies into the data leading to artifacts. There remains a need for robust and effective motion correction. One approach uses the (corrupt) data itself to derive the patient position at each projection angle. Corrected data is periodically incorporated into a 3-D reconstruction. Fundamental aspects of the algorithm mechanics, particularly performance in the presence of Poisson noise, have been examined. Brain SPECT studies were simulated using a digital version of the Huffman brain phantom. Projection datasets with Poisson noise imposed, generated for different positions of the phantom, were combined and reconstructed to produce motion-corrupted reconstructions. To examine the behaviour of the cost function as the object position was changed, the corrupted re-construction was forward projected and the mean square difference (MSD) between the resulting re-projections and corresponding original projections was calculated. The ability to detect mis-positioned projections for different degrees of freedom, the importance of using dual-head camera geometry, and the effect of smoothing the original projections prior to the MSD calculation were assessed. Re-projection of the corrupt reconstruction was able to correctly identify mis-positioned projection data. The degree of movement as defined by MSD was more easily identified for translations than for rotations. Noise resulted in an increasing bias that made it difficult to distinguish the minimum MSD, particularly for z-axis rotations. This was improved by median filtering of projections. Right-angled dual-head geometry is necessary to provide stability to the algorithm and to better identify motion in all 6 degrees of freedom. These findings will assist the optimisation of a fully automated motion

  1. Computer holography: 3D digital art based on high-definition CGH

    International Nuclear Information System (INIS)

    Matsushima, K; Arima, Y; Nishi, H; Yamashita, H; Yoshizaki, Y; Ogawa, K; Nakahara, S

    2013-01-01

    Our recent works of high-definition computer-generated holograms (CGH) and the techniques used for the creation, such as the polygon-based method, silhouette method and digitized holography, are summarized and reviewed in this paper. The concept of computer holography is proposed in terms of integrating and crystalizing the techniques into novel digital art.

  2. Step-by-step guide to building an inexpensive 3D printed motorized positioning stage for automated high-content screening microscopy.

    Science.gov (United States)

    Schneidereit, Dominik; Kraus, Larissa; Meier, Jochen C; Friedrich, Oliver; Gilbert, Daniel F

    2017-06-15

    High-content screening microscopy relies on automation infrastructure that is typically proprietary, non-customizable, costly and requires a high level of skill to use and maintain. The increasing availability of rapid prototyping technology makes it possible to quickly engineer alternatives to conventional automation infrastructure that are low-cost and user-friendly. Here, we describe a 3D printed inexpensive open source and scalable motorized positioning stage for automated high-content screening microscopy and provide detailed step-by-step instructions to re-building the device, including a comprehensive parts list, 3D design files in STEP (Standard for the Exchange of Product model data) and STL (Standard Tessellation Language) format, electronic circuits and wiring diagrams as well as software code. System assembly including 3D printing requires approx. 30h. The fully assembled device is light-weight (1.1kg), small (33×20×8cm) and extremely low-cost (approx. EUR 250). We describe positioning characteristics of the stage, including spatial resolution, accuracy and repeatability, compare imaging data generated with our device to data obtained using a commercially available microplate reader, demonstrate its suitability to high-content microscopy in 96-well high-throughput screening format and validate its applicability to automated functional Cl - - and Ca 2+ -imaging with recombinant HEK293 cells as a model system. A time-lapse video of the stage during operation and as part of a custom assembled screening robot can be found at https://vimeo.com/158813199. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Impact of 4D image quality on the accuracy of target definition

    DEFF Research Database (Denmark)

    Nielsen, Tine Bjørn; Hansen, Christian Rønn; Westberg, Jonas

    2016-01-01

    that there was a large distortion of the imaged target shape. Imaging uncertainties of standard 4D systems are of similar size as typical GTV-CTV expansions (0.5-1 cm) and contribute considerably to the target definition uncertainty. Optimising and validating 4D systems is recommended in order to obtain the most optimal...

  4. 2D vs. 3D imaging in laparoscopic surgery-results of a prospective randomized trial.

    Science.gov (United States)

    Buia, Alexander; Stockhausen, Florian; Filmann, Natalie; Hanisch, Ernst

    2017-12-01

    3D imaging is an upcoming technology in laparoscopic surgery, and recent studies have shown that the modern 3D technique is superior in an experimental setting. However, the first randomized controlled clinical trial in this context dates back to 1998 and showed no significant difference between 2D and 3D visualization using the first 3D generation technique, which is now more than 15 years old. Positive results measured in an experimental setting considering 3D imaging on surgical performance led us to initiate a randomized controlled pragmatic clinical trial to validate our findings in daily clinical routine. Standard laparoscopic operations (cholecystectomy, appendectomy) were preoperatively randomized to a 2D or 3D imaging system. We used a surgical comfort scale (Likert scale) and the Raw NASA Workload TLX for the subjective assessment of 2D and 3D imaging; the duration of surgery was also measured. The results of 3D imaging were statistically significant better than 2D imaging concerning the parameters "own felt safety" and "task efficiency"; the difficulty level of the procedures in the 2D and 3D groups did not differ. Overall, the Raw NASA Workload TLX showed no significance between the groups. 3D imaging could be a possible advantage in laparoscopic surgery. The results of our clinical trial show increased personal felt safety and efficiency of the surgeon using a 3D imaging system. Overall of the procedures, the findings assessed using Likert scales in terms of own felt safety and task efficiency were statistically significant for 3D imaging. The individually perceived workload assessed with the Raw NASA TLX shows no difference. Although these findings are subjective impressions of the performing surgeons without a clear benefit for 3D technology in clinical outcome, we think that these results show the capability that 3D laparoscopy can have a positive impact while performing laparoscopic procedures.

  5. 32 CFR 154.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ..., National Security Agency/Central Security Service; Director, Defense Intelligence Agency; Assistant Chief... Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE SECURITY DEPARTMENT OF DEFENSE PERSONNEL SECURITY PROGRAM REGULATION General Provisions § 154.3 Definitions. (a) Access. The ability and opportunity...

  6. 30 CFR 795.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SMALL OPERATOR ASSISTANCE PERMANENT REGULATORY PROGRAM-SMALL OPERATOR ASSISTANCE PROGRAM § 795.3 Definitions. As used in... who has the authority and responsibility for overall management of the Small Operator Assistance...

  7. 16 CFR 680.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT AFFILIATE MARKETING § 680.3 Definitions. As... exercise, directly or indirectly, a controlling influence over the management or policies of a company, as... any corporation, limited liability company, business trust, general or limited partnership...

  8. GOTHIC CHURCHES IN PARIS ST GERVAIS ET ST PROTAIS IMAGE MATCHING 3D RECONSTRUCTION TO UNDERSTAND THE VAULTS SYSTEM GEOMETRY

    Directory of Open Access Journals (Sweden)

    M. Capone

    2015-02-01

    benefits and the troubles. From a methodological point of view this is our workflow: - theoretical study about geometrical configuration of rib vault systems; - 3D model based on theoretical hypothesis about geometric definition of the vaults' form; - 3D model based on image matching 3D reconstruction methods; - comparison between 3D theoretical model and 3D model based on image matching;

  9. Multiple organ definition in CT using a Bayesian approach for 3D model fitting

    Science.gov (United States)

    Boes, Jennifer L.; Weymouth, Terry E.; Meyer, Charles R.

    1995-08-01

    Organ definition in computed tomography (CT) is of interest for treatment planning and response monitoring. We present a method for organ definition using a priori information about shape encoded in a set of biometric organ models--specifically for the liver and kidney-- that accurately represents patient population shape information. Each model is generated by averaging surfaces from a learning set of organ shapes previously registered into a standard space defined by a small set of landmarks. The model is placed in a specific patient's data set by identifying these landmarks and using them as the basis for model deformation; this preliminary representation is then iteratively fit to the patient's data based on a Bayesian formulation of the model's priors and CT edge information, yielding a complete organ surface. We demonstrate this technique using a set of fifteen abdominal CT data sets for liver surface definition both before and after the addition of a kidney model to the fitting; we demonstrate the effectiveness of this tool for organ surface definition in this low-contrast domain.

  10. 17 CFR 240.3b-2 - Definition of “officer”.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Definition of âofficerâ. 240... Securities Exchange Act of 1934 Definitions § 240.3b-2 Definition of “officer”. The term officer means a... accounting officer, and any person routinely performing corresponding functions with respect to any...

  11. Revisiting the concept level of detail in 3D city modelling

    NARCIS (Netherlands)

    Biljecki, F.; Zhao, J.; Stoter, J.E.; Ledoux, H.

    2013-01-01

    This review paper discusses the concept of level of detail in 3D city modelling, and is a first step towards a foundation for a standardised definition. As an introduction, a few level of detail specifications, outlooks and approaches are given from the industry. The paper analyses the general

  12. Maxwell: A semi-analytic 4D code for earthquake cycle modeling of transform fault systems

    Science.gov (United States)

    Sandwell, David; Smith-Konter, Bridget

    2018-05-01

    We have developed a semi-analytic approach (and computational code) for rapidly calculating 3D time-dependent deformation and stress caused by screw dislocations imbedded within an elastic layer overlying a Maxwell viscoelastic half-space. The maxwell model is developed in the Fourier domain to exploit the computational advantages of the convolution theorem, hence substantially reducing the computational burden associated with an arbitrarily complex distribution of force couples necessary for fault modeling. The new aspect of this development is the ability to model lateral variations in shear modulus. Ten benchmark examples are provided for testing and verification of the algorithms and code. One final example simulates interseismic deformation along the San Andreas Fault System where lateral variations in shear modulus are included to simulate lateral variations in lithospheric structure.

  13. 3D Reconstruction of the Retinal Arterial Tree Using Subject-Specific Fundus Images

    Science.gov (United States)

    Liu, D.; Wood, N. B.; Xu, X. Y.; Witt, N.; Hughes, A. D.; Samcg, Thom

    Systemic diseases, such as hypertension and diabetes, are associated with changes in the retinal microvasculature. Although a number of studies have been performed on the quantitative assessment of the geometrical patterns of the retinal vasculature, previous work has been confined to 2 dimensional (2D) analyses. In this paper, we present an approach to obtain a 3D reconstruction of the retinal arteries from a pair of 2D retinal images acquired in vivo. A simple essential matrix based self-calibration approach was employed for the "fundus camera-eye" system. Vessel segmentation was performed using a semi-automatic approach and correspondence between points from different images was calculated. The results of 3D reconstruction show the centreline of retinal vessels and their 3D curvature clearly. Three-dimensional reconstruction of the retinal vessels is feasible and may be useful in future studies of the retinal vasculature in disease.

  14. Creating physical 3D stereolithograph models of brain and skull.

    Directory of Open Access Journals (Sweden)

    Daniel J Kelley

    2007-10-01

    Full Text Available The human brain and skull are three dimensional (3D anatomical structures with complex surfaces. However, medical images are often two dimensional (2D and provide incomplete visualization of structural morphology. To overcome this loss in dimension, we developed and validated a freely available, semi-automated pathway to build 3D virtual reality (VR and hand-held, stereolithograph models. To evaluate whether surface visualization in 3D was more informative than in 2D, undergraduate students (n = 50 used the Gillespie scale to rate 3D VR and physical models of both a living patient-volunteer's brain and the skull of Phineas Gage, a historically famous railroad worker whose misfortune with a projectile tamping iron provided the first evidence of a structure-function relationship in brain. Using our processing pathway, we successfully fabricated human brain and skull replicas and validated that the stereolithograph model preserved the scale of the VR model. Based on the Gillespie ratings, students indicated that the biological utility and quality of visual information at the surface of VR and stereolithograph models were greater than the 2D images from which they were derived. The method we developed is useful to create VR and stereolithograph 3D models from medical images and can be used to model hard or soft tissue in living or preserved specimens. Compared to 2D images, VR and stereolithograph models provide an extra dimension that enhances both the quality of visual information and utility of surface visualization in neuroscience and medicine.

  15. 23 CFR 1335.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... Crash Criteria (MMUCC) published by the National Highway Traffic Safety Administration and the Federal... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION STATE HIGHWAY SAFETY DATA IMPROVEMENTS § 1335.3 Definitions. As used in this part: (a) Highway safety data and traffic records means data and...

  16. 5 CFR 2414.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... or written communication not on the public record with respect to which reasonable prior notice to... Administrative Personnel FEDERAL LABOR RELATIONS AUTHORITY, GENERAL COUNSEL OF THE FEDERAL LABOR RELATIONS AUTHORITY AND FEDERAL SERVICE IMPASSES PANEL GENERAL PROVISIONS EX PARTE COMMUNICATIONS § 2414.3 Definitions...

  17. 7 CFR 1467.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS WETLANDS RESERVE PROGRAM § 1467.3 Definitions. The... by a native corporation, Tribe or the Bureau of Indian Affairs (BIA). Activity means an action other..., or enhanced through an easement, contract, or restoration cost-share agreement. Agreement means the...

  18. A 3D Model Based Imdoor Navigation System for Hubei Provincial Museum

    Science.gov (United States)

    Xu, W.; Kruminaite, M.; Onrust, B.; Liu, H.; Xiong, Q.; Zlatanova, S.

    2013-11-01

    3D models are more powerful than 2D maps for indoor navigation in a complicate space like Hubei Provincial Museum because they can provide accurate descriptions of locations of indoor objects (e.g., doors, windows, tables) and context information of these objects. In addition, the 3D model is the preferred navigation environment by the user according to the survey. Therefore a 3D model based indoor navigation system is developed for Hubei Provincial Museum to guide the visitors of museum. The system consists of three layers: application, web service and navigation, which is built to support localization, navigation and visualization functions of the system. There are three main strengths of this system: it stores all data needed in one database and processes most calculations on the webserver which make the mobile client very lightweight, the network used for navigation is extracted semi-automatically and renewable, the graphic user interface (GUI), which is based on a game engine, has high performance of visualizing 3D model on a mobile display.

  19. Comparison of Transport Calculation Between 2D/1D synthesis and RAPTOR-M3G at Core Barrel of Korea Standard Nuclear Plant(KSNP), OPR-1000

    Energy Technology Data Exchange (ETDEWEB)

    Maeng, Young Jae; Kim, Byoung Chul; Lim, Mi Joung; Kim, Kyung Sik; Jeon, Young Kyou [Korea Reactor Integrity Surveillance Technology, Daejeon (Korea, Republic of); Yoo, Chun Sung [Korea Atomic Energy Research Institutes, Daejeon (Korea, Republic of)

    2013-10-15

    The DORT code for 2D/1D synthesis has been actively applied to calculate the fast neutron (E>1.0MeV) fluence exposure of RPV. RAPTOR-M3G code is also applied for the comparison of 2D/1D synthesis, and it was found that 2D/1D synthesis method generally provided more conservative results than RAPTOR-M3G at both RPV and surveillance capsule locations. As a result, definitely RAPTOR-M3G for 3D calculation must apply for accurate evaluation of the integrity and ageing of RPV and internal structures. Therefore, the purpose of this paper is to compare the differences in terms of geometric aspect of KSNP model between 2D/1D synthesis and RAPTOR-M3G at core barrel area. 2D/1D synthesis method shows still higher results at the shortest distance of bypass water region. The reason is that 2D/1D synthesis method has excessive conservatism because of having just one model of R-θ and R-Z separately. Angles (5, 25, 45, 65 and 90 degrees) that RAPTOR-M3G results are higher than 2D/1D synthesis results seem to have almost regular interval. The reason can be that neutron flux to reach to barrel is affected by the nearest core definitely and all of near core areas including bypass water. RAPTOR-M3G performing 3D calculation can be applied to various reactor structures, because the code can simulate the model realistically and reasonably in geometric view points. Understanding the phenomenon that 45 degree shows downward peak, in spite of baffle corner location, remains.

  20. Comparison of Transport Calculation Between 2D/1D synthesis and RAPTOR-M3G at Core Barrel of Korea Standard Nuclear Plant(KSNP), OPR-1000

    International Nuclear Information System (INIS)

    Maeng, Young Jae; Kim, Byoung Chul; Lim, Mi Joung; Kim, Kyung Sik; Jeon, Young Kyou; Yoo, Chun Sung

    2013-01-01

    The DORT code for 2D/1D synthesis has been actively applied to calculate the fast neutron (E>1.0MeV) fluence exposure of RPV. RAPTOR-M3G code is also applied for the comparison of 2D/1D synthesis, and it was found that 2D/1D synthesis method generally provided more conservative results than RAPTOR-M3G at both RPV and surveillance capsule locations. As a result, definitely RAPTOR-M3G for 3D calculation must apply for accurate evaluation of the integrity and ageing of RPV and internal structures. Therefore, the purpose of this paper is to compare the differences in terms of geometric aspect of KSNP model between 2D/1D synthesis and RAPTOR-M3G at core barrel area. 2D/1D synthesis method shows still higher results at the shortest distance of bypass water region. The reason is that 2D/1D synthesis method has excessive conservatism because of having just one model of R-θ and R-Z separately. Angles (5, 25, 45, 65 and 90 degrees) that RAPTOR-M3G results are higher than 2D/1D synthesis results seem to have almost regular interval. The reason can be that neutron flux to reach to barrel is affected by the nearest core definitely and all of near core areas including bypass water. RAPTOR-M3G performing 3D calculation can be applied to various reactor structures, because the code can simulate the model realistically and reasonably in geometric view points. Understanding the phenomenon that 45 degree shows downward peak, in spite of baffle corner location, remains

  1. Interactive 3D Mars Visualization

    Science.gov (United States)

    Powell, Mark W.

    2012-01-01

    The Interactive 3D Mars Visualization system provides high-performance, immersive visualization of satellite and surface vehicle imagery of Mars. The software can be used in mission operations to provide the most accurate position information for the Mars rovers to date. When integrated into the mission data pipeline, this system allows mission planners to view the location of the rover on Mars to 0.01-meter accuracy with respect to satellite imagery, with dynamic updates to incorporate the latest position information. Given this information so early in the planning process, rover drivers are able to plan more accurate drive activities for the rover than ever before, increasing the execution of science activities significantly. Scientifically, this 3D mapping information puts all of the science analyses to date into geologic context on a daily basis instead of weeks or months, as was the norm prior to this contribution. This allows the science planners to judge the efficacy of their previously executed science observations much more efficiently, and achieve greater science return as a result. The Interactive 3D Mars surface view is a Mars terrain browsing software interface that encompasses the entire region of exploration for a Mars surface exploration mission. The view is interactive, allowing the user to pan in any direction by clicking and dragging, or to zoom in or out by scrolling the mouse or touchpad. This set currently includes tools for selecting a point of interest, and a ruler tool for displaying the distance between and positions of two points of interest. The mapping information can be harvested and shared through ubiquitous online mapping tools like Google Mars, NASA WorldWind, and Worldwide Telescope.

  2. Constraint of semi-elliptical surface cracks in T and L-joints

    International Nuclear Information System (INIS)

    Lee, Hyung Yil

    2001-01-01

    Critical defects in pressure vessels and pipes are generally found in the form of a semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. Furthermore, in addition to the traditional single parameter K or J-integral, the second parameter like T-stress should be measured to quantify the constraint effect. In this work, the validity of the line-spring finite element is investigated by comparing line-spring J-T solutions to the reference 3D finite element J-T solutions. A full 3D-mesh generating program for semi-elliptical surface cracks is employed to provide such reference 3D solutions. Then some structural characteristics of the surface-cracked T and L-joints are studied by mixed mode line-spring finite element. Negative T-stresses observed in T and L-joints indicate the necessity of J-T two parameter approach for analyses of surface-cracked T and L-joints

  3. Interpretation of mandibular condyle fractures using 2D- and 3D-computed tomography

    Directory of Open Access Journals (Sweden)

    Costa e Silva Adriana Paula de Andrade da

    2003-01-01

    Full Text Available Computed tomography (CT has been increasingly used in the examination of patients with craniofacial trauma. This technique is useful in the examination of the temporomandibular joint and allows the diagnosis of fractures of the mandibular condyle. Aiming to verify whether the three-dimensional reconstructed images from CT (3D-CT produce more effective visual information than the two-dimensional (2D-CT ones, we evaluated 2D-CT and 3D-CT examinations of 18 patients with mandibular condyle fractures. We observed that 2D-CT and 3D-CT reconstructed images produced similar information for the diagnosis of fractures of the mandibular condyle, although the 3D-CT allowed a better visualization of the position and displacement of bone fragments, as well as the comminution of fractures. These results, together with the possibility of refining and manipulating perspectives in 3D images, reinforce the importance of its use in the surgical planning and evaluation of treatment. We concluded that 3D-CT presented supplementary information for a more effective diagnosis of mandibular condyle fractures.

  4. 48 CFR 204.7101 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Uniform Contract Line Item Numbering System 204.7101 Definitions. Accounting classification reference number (ACRN) means any combination of a two position alpha... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Definitions. 204.7101...

  5. Dimensional reduction for D3-brane moduli

    International Nuclear Information System (INIS)

    Cownden, Brad; Frey, Andrew R.; Marsh, M.C. David; Underwood, Bret

    2016-01-01

    Warped string compactifications are central to many attempts to stabilize moduli and connect string theory with cosmology and particle phenomenology. We present a first-principles derivation of the low-energy 4D effective theory from dimensional reduction of a D3-brane in a warped Calabi-Yau compactification of type IIB string theory with imaginary self-dual 3-form flux, including effects of D3-brane motion beyond the probe approximation, and find the metric on the moduli space of brane positions, the universal volume modulus, and axions descending from the 4-form potential. As D3-branes may be considered as carrying either electric or magnetic charges for the self-dual 5-form field strength, we present calculations in both duality frames. Our results are consistent with, but extend significantly, earlier results on the low-energy effective theory arising from D3-branes in string compactifications.

  6. 10 CFR 209.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... pursuant to the Agreement on an International Energy Program signed at Paris on November 18, 1974, including (1) the Annex entitled “Emergency Reserves”, (2) any amendment to such Agreement which includes... ENERGY OIL INTERNATIONAL VOLUNTARY AGREEMENTS General Provisions § 209.3 Definitions. For purposes of...

  7. 16 CFR 1205.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY... more cutting blades rotate in essentially a horizontal plane about at least one vertical axis. (15... the mower. (b) Where applicable, the definitions in section 3 of the Consumer Product Safety Act (15 U...

  8. 22 CFR 192.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION General § 192.3 Definitions. When used in this subchapter, unless otherwise specified, the terms— (a) Secretary of State includes any person to whom the Secretary of State has delegated the responsibilities of carrying out this...

  9. 32 CFR 1285.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... Defense Other Regulations Relating to National Defense DEFENSE LOGISTICS AGENCY MISCELLANEOUS DEFENSE LOGISTICS AGENCY FREEDOM OF INFORMATION ACT PROGRAM § 1285.3 Definitions. The following terms and meanings... independently on FOIA requests. A DLA activity has its own FOIA manager, initial denial authority, and office of...

  10. 21 CFR 120.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... CONSUMPTION HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS General Provisions § 120.3 Definitions... and technical information to determine whether the HACCP plan, when properly implemented, will... monitoring, that establish the validity of the HACCP plan and that the system is operating according to the...

  11. 23 CFR 627.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... life-cycle cost without sacrificing safety, necessary quality, and environmental attributes of the... § 627.3 Definitions. Project. A portion of a highway that a State proposes to construct, reconstruct, or improve as described in the preliminary design report or applicable environmental document. A project may...

  12. 21 CFR 606.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS General Provisions § 606.3 Definitions. As... current good manufacturing practices. [40 FR 53532, Nov. 18, 1975, as amended at 64 FR 45370, Aug. 19...) Facilities means any area used for the collection, processing, compatibility testing, storage or distribution...

  13. Case study: Beauty and the Beast 3D: benefits of 3D viewing for 2D to 3D conversion

    Science.gov (United States)

    Handy Turner, Tara

    2010-02-01

    From the earliest stages of the Beauty and the Beast 3D conversion project, the advantages of accurate desk-side 3D viewing was evident. While designing and testing the 2D to 3D conversion process, the engineering team at Walt Disney Animation Studios proposed a 3D viewing configuration that not only allowed artists to "compose" stereoscopic 3D but also improved efficiency by allowing artists to instantly detect which image features were essential to the stereoscopic appeal of a shot and which features had minimal or even negative impact. At a time when few commercial 3D monitors were available and few software packages provided 3D desk-side output, the team designed their own prototype devices and collaborated with vendors to create a "3D composing" workstation. This paper outlines the display technologies explored, final choices made for Beauty and the Beast 3D, wish-lists for future development and a few rules of thumb for composing compelling 2D to 3D conversions.

  14. Optimizing area under the ROC curve using semi-supervised learning.

    Science.gov (United States)

    Wang, Shijun; Li, Diana; Petrick, Nicholas; Sahiner, Berkman; Linguraru, Marius George; Summers, Ronald M

    2015-01-01

    Receiver operating characteristic (ROC) analysis is a standard methodology to evaluate the performance of a binary classification system. The area under the ROC curve (AUC) is a performance metric that summarizes how well a classifier separates two classes. Traditional AUC optimization techniques are supervised learning methods that utilize only labeled data (i.e., the true class is known for all data) to train the classifiers. In this work, inspired by semi-supervised and transductive learning, we propose two new AUC optimization algorithms hereby referred to as semi-supervised learning receiver operating characteristic (SSLROC) algorithms, which utilize unlabeled test samples in classifier training to maximize AUC. Unlabeled samples are incorporated into the AUC optimization process, and their ranking relationships to labeled positive and negative training samples are considered as optimization constraints. The introduced test samples will cause the learned decision boundary in a multidimensional feature space to adapt not only to the distribution of labeled training data, but also to the distribution of unlabeled test data. We formulate the semi-supervised AUC optimization problem as a semi-definite programming problem based on the margin maximization theory. The proposed methods SSLROC1 (1-norm) and SSLROC2 (2-norm) were evaluated using 34 (determined by power analysis) randomly selected datasets from the University of California, Irvine machine learning repository. Wilcoxon signed rank tests showed that the proposed methods achieved significant improvement compared with state-of-the-art methods. The proposed methods were also applied to a CT colonography dataset for colonic polyp classification and showed promising results.

  15. a Uav Based 3-D Positioning Framework for Detecting Locations of Buried Persons in Collapsed Disaster Area

    Science.gov (United States)

    Moon, H.; Kim, C.; Lee, W.

    2016-06-01

    Regarding spatial location positioning, indoor location positioning theories based on wireless communication techniques such as Wi-Fi, beacon, UWB and Bluetooth has widely been developing across the world. These techniques are mainly focusing on spatial location detection of customers using fixed wireless APs and unique Tags in the indoor environment. Besides, since existing detection equipment and techniques using ultrasound or sound etc. to detect buried persons and identify survival status for them cause 2nd damages on the collapsed debris for rescuers. In addition, it might take time to check the buried persons. However, the collapsed disaster sites should consider both outdoor and indoor environments because empty spaces under collapsed debris exists. In order to detect buried persons from the empty spaces, we should collect wireless signals with Wi-Fi from their mobile phone. Basically, the Wi-Fi signal measure 2-D location. However, since the buried persons have Z value with burial depth, we also should collect barometer sensor data from their mobile phones in order to measure Z values according to weather conditions. Specially, for quick accessibility to the disaster area, a drone (UAV; Unmanned Arial Vehicle) system, which is equipped with a wireless detection module, was introduced. Using these framework, this study aims to provide the rescuers with effective rescue information by calculating 3-D location for buried persons based on the wireless and barometer sensor fusion.

  16. Interactive initialization of 2D/3D rigid registration

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ren Hui; Güler, Özgür [The Sheikh Zayed Institute for Pediatric Surgical Innovation, Children' s National Medical Center, Washington, DC 20010 (United States); Kürklüoglu, Mustafa [Department of Cardiac Surgery, Children' s National Medical Center, Washington, DC 20010 (United States); Lovejoy, John [Department of Orthopaedic Surgery and Sports Medicine, Children' s National Medical Center, Washington, DC 20010 (United States); Yaniv, Ziv, E-mail: ZYaniv@childrensnational.org [The Sheikh Zayed Institute for Pediatric Surgical Innovation, Children' s National Medical Center, Washington, DC 20010 and Departments of Pediatrics and Radiology, George Washington University, Washington, DC 20037 (United States)

    2013-12-15

    Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on

  17. Interactive initialization of 2D/3D rigid registration

    International Nuclear Information System (INIS)

    Gong, Ren Hui; Güler, Özgür; Kürklüoglu, Mustafa; Lovejoy, John; Yaniv, Ziv

    2013-01-01

    Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on the

  18. Complex Structures in Sediments Overlying Sinkholes: 3D-GPR and Azimuthal Resistivity Imaging

    Science.gov (United States)

    Kruse, S.; Kiflu, H. G.; Ammar, A. I., Sr.; Karashay, P., III; Marshall, A. M.; McNiff, C. M.

    2014-12-01

    3D GPR surveys in the covered karst terrain of west-central Florida, USA, reveal surprising geometries of surficial sediments. Several meters of surficial sands overlie progressively more clay-rich sediments, which in turn overlie weathered limestone. The top of a clay-rich horizon produces an exceptionally clear GPR reflector visible from depths between 0.5 and ~8 meters. On length scales of 10-20 meters, the geometry of this horizon as it drapes over underlying weathered limestone suggests that depressions are not conical, but instead more complex troughs that surround domed stratigraphic highs. Azimuthal semi-variograms of the clay horizon depth show greatest correlation in directions that are aligned with the direction of elevated resistivities at depths to 10-14 meters. One possible interpretation is that dissolution in underlying limestone is concentrated in elongated zones rather than in columnar or spherical voids. Elongated sand-filled depressions in the clay layer produce azimuthal resistivity highs in the direction of the elongation. This direction in turn corresponds to the major axis of depressions in the clay-rich GPR reflecting horizon. Groundwater recharge in this area is concentrated into conduits that breach the clay-rich units that overlie the limestone aquifer. This study suggests that the conduits themselves may be elongated features rather than cylindrical in form. Recharge flow paths may be more complex than previously recognized. The high-resolution GPR images require 3D surveys with 250 MHz and 500 MHz antennas, with 10-cm line spacings, careful corrections for antenna positions and 3D migrations of the data.

  19. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  20. Procedure for image acquisition and dosimetric planning for prostate cancer with 3D-CRT in the MIRS 3.0

    International Nuclear Information System (INIS)

    Perez Velasquez, Reytel; Alvarez Zaldivar, Junior; Gonzalez Lopez, Nadia

    2009-01-01

    For over 30 years in the department of Radiotherapy of the Lenin Hospital has been doing conventional radiotherapy. In this paper we describe the dose planning procedure for patients with prostate cancer with 3D-CRT in the MIRS RTPS 3.0. The work ranges from imaging in the TAC including quality control of this, the definition of bodies radio therapists medical risk to the data to be transferred to processing machine. With this procedure we have established guidelines for planning 3D-CRT treatments for other locations. (author)

  1. Experience of vitamin D3 combined therapy in atopic dermatitis in children

    OpenAIRE

    Selska Z.V.

    2016-01-01

    Purpose. To investigate the efficacy of vitamin D3 in the treatment of atopic dermatitis in children. Materials and methods. We examined 42 children with atopic dermatitis. In 7 (16.7±5.8%) children had mild atopic dermatitis, 22 (52.4±7.7%) children had moderate severity of the disease, and 13 (31.0±7.1%) children diagnosed with severe degree of illness. Patients were aged 3 to 16 years. Definition 25(OH)D was performed using elektrochemiluminestsencysi method. Results. Average indicat...

  2. Change in serum 25-hydroxyvitamin D with antiretroviral treatment initiation and nutritional intervention in HIV-positive adults

    DEFF Research Database (Denmark)

    Yilma, Daniel; Kæstel, Pernille; Olsen, Mette Frahm

    2016-01-01

    daily allowance of vitamin D (10 μg/200 g). The level of serum 25(OH)D before nutritional intervention and ART initiation was compared with serum 25(OH)D of HIV-negative individuals. A total of 348 HIV-positive and 100 HIV-negative persons were recruited. The median baseline serum 25(OH)D level......Low vitamin D level in HIV-positive persons has been associated with disease progression. We compared the levels of serum 25-hydroxyvitamin D (25(OH)D) in HIV-positive and HIV-negative persons, and investigated the role of nutritional supplementation and antiretroviral treatment (ART) on serum 25...... was higher in HIV-positive than in HIV-negative persons (42·5 v. 35·3 nmol/l, P17 kg/m2 were randomised to either LNS supplementation (n 189) or no supplementation (n 93) during the first 3 months of ART. The supplemented group had a 4·1 (95 % CI 1·7, 6·4) nmol/l increase in serum 25(OH)D, whereas the non...

  3. RELAP5-3D Developmental Assessment: Comparison of Versions 4.2.1i and 4.1.3i

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-06-01

    Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.2.1i and 4.1.3i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

  4. Semi-Infinite Geology Modeling Algorithm (SIGMA): a Modular Approach to 3D Gravity

    Science.gov (United States)

    Chang, J. C.; Crain, K.

    2015-12-01

    Conventional 3D gravity computations can take up to days, weeks, and even months, depending on the size and resolution of the data being modeled. Additional modeling runs, due to technical malfunctions or additional data modifications, only compound computation times even further. We propose a new modeling algorithm that utilizes vertical line elements to approximate mass, and non-gridded (point) gravity observations. This algorithm is (1) magnitudes faster than conventional methods, (2) accurate to less than 0.1% error, and (3) modular. The modularity of this methodology means that researchers can modify their geology/terrain or gravity data, and only the modified component needs to be re-run. Additionally, land-, sea-, and air-based platforms can be modeled at their observation point, without having to filter data into a synthesized grid.

  5. 3D Visualization for Planetary Missions

    Science.gov (United States)

    DeWolfe, A. W.; Larsen, K.; Brain, D.

    2018-04-01

    We have developed visualization tools for viewing planetary orbiters and science data in 3D for both Earth and Mars, using the Cesium Javascript library, allowing viewers to visualize the position and orientation of spacecraft and science data.

  6. 32 CFR 323.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... DEFENSE LOGISTICS AGENCY PRIVACY PROGRAM § 323.3 Definitions. (a) Access. The review of a record or a copy... single agency. For all other purposes including applications for access and amendment, denial of access..., vulnerabilities, and the cost to a computer facility or word processing activity in safeguarding personal...

  7. 21 CFR 203.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... PRESCRIPTION DRUG MARKETING General Provisions § 203.3 Definitions. (a) The act means the Federal Food, Drug..., data, audio, pictorial, or other information representation in digital form that is created, modified... same marketing or service area, or nearby licensed practitioners, of drugs for use in the treatment of...

  8. 14 CFR 142.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... OTHER CERTIFICATED AGENCIES TRAINING CENTERS General § 142.3 Definitions. As used in this part: Advanced Flight Training Device as used in this part, means a flight training device as defined in part 61 of this... program of instruction to obtain pilot certification, qualification, authorization, or currency; (2) A...

  9. Measurement of CSF volume with 3D-FASE MRI

    International Nuclear Information System (INIS)

    Kanayama, Shoichi; Calderon, A.; Makita, Jun-ichi; Ohara, Yukou; Tsunoda, Akira; Sato, Kiyoshi.

    1997-01-01

    A noninvasive and fast cerebrospinal fluid (CSF) volume measurement method has been developed using 3D-FASE MRI and a semi-automatic segmentation process. Images with a high CSF/(gray and white matter) ratio (about 10-20) were obtained with a heavily T 2 weighted 3D-FASE sequence. The CSF region was segmented with a region growing method and the volume was calculated from the number of segmented voxels with a signal intensity weighted summation. Total measurement time was about 30 minutes for each study. The errors of the measured volumes were within 10% for the phantom experiments. Intracranial CSF volumes of normal volunteers ranged between about 100 and 200 cc and the ventricle/intracranial CSF ratio was about 10%. 3D display of the segmented intracranial and ventricle CSF regions was also carried out and proved to be useful to understand the anatomy. Increased intracranial and/or ventricle CSF volumes were obtained for a hydrocephalic patient and one patient with probable cerebral atrophy. The results suggest that the developed method could be used for the diagnosis of patients with neurological diseases. (author)

  10. 3D Filament Network Segmentation with Multiple Active Contours

    Science.gov (United States)

    Xu, Ting; Vavylonis, Dimitrios; Huang, Xiaolei

    2014-03-01

    Fluorescence microscopy is frequently used to study two and three dimensional network structures formed by cytoskeletal polymer fibers such as actin filaments and microtubules. While these cytoskeletal structures are often dilute enough to allow imaging of individual filaments or bundles of them, quantitative analysis of these images is challenging. To facilitate quantitative, reproducible and objective analysis of the image data, we developed a semi-automated method to extract actin networks and retrieve their topology in 3D. Our method uses multiple Stretching Open Active Contours (SOACs) that are automatically initialized at image intensity ridges and then evolve along the centerlines of filaments in the network. SOACs can merge, stop at junctions, and reconfigure with others to allow smooth crossing at junctions of filaments. The proposed approach is generally applicable to images of curvilinear networks with low SNR. We demonstrate its potential by extracting the centerlines of synthetic meshwork images, actin networks in 2D TIRF Microscopy images, and 3D actin cable meshworks of live fission yeast cells imaged by spinning disk confocal microscopy.

  11. Determination of the positions and orientations of concentrated rod-like colloids from 3D microscopy data

    International Nuclear Information System (INIS)

    Besseling, T H; Hermes, M; Kuijk, A; De Nijs, B; Deng, T-S; Dijkstra, M; Imhof, A; Van Blaaderen, A

    2015-01-01

    Confocal microscopy in combination with real-space particle tracking has proven to be a powerful tool in scientific fields such as soft matter physics, materials science and cell biology. However, 3D tracking of anisotropic particles in concentrated phases remains not as optimized compared to algorithms for spherical particles. To address this problem, we developed a new particle-fitting algorithm that can extract the positions and orientations of fluorescent rod-like particles from three dimensional confocal microscopy data stacks. The algorithm is tailored to work even when the fluorescent signals of the particles overlap considerably and a threshold method and subsequent clusters analysis alone do not suffice. We demonstrate that our algorithm correctly identifies all five coordinates of uniaxial particles in both a concentrated disordered phase and a liquid-crystalline smectic-B phase. Apart from confocal microscopy images, we also demonstrate that the algorithm can be used to identify nanorods in 3D electron tomography reconstructions. Lastly, we determined the accuracy of the algorithm using both simulated and experimental confocal microscopy data-stacks of diffusing silica rods in a dilute suspension. This novel particle-fitting algorithm allows for the study of structure and dynamics in both dilute and dense liquid-crystalline phases (such as nematic, smectic and crystalline phases) as well as the study of the glass transition of rod-like particles in three dimensions on the single particle level. (paper)

  12. Populisme et démocratie semi-directe : la dénaturation des procédés référendaires en France et aux Etats-Unis

    Directory of Open Access Journals (Sweden)

    Christophe Premat

    2005-09-01

    Full Text Available Si le populisme se caractérise par l’incarnation d’un ensemble de frustrations à l’égard du système représentatif, il est primordial de s’interroger sur le lien entre une déception à l’égard des institutions et les instruments de démocratie semi-directe. En nous appuyant sur une comparaison entre la France et les Etats-Unis pour analyser d´une part comment le référendum et l’initiative populaire ont modifié la donne dans certains Etats américains et d’autre part comment en France les référendums nationaux ont connu la suspicion « plébiscitaire » à plusieurs reprises, nous souhaiterions comprendre si par nature la démocratie semi-directe n’est que le ressentiment engendré par la lenteur du travail de représentation ou si elle est le complément essentiel à la transformation du régime représentatif.Si la frustración contra el sistema representativo es expresada por el populismo, es crucial interrogarse por el acoplamiento entre una decepción relacionada con las instituciones y los instrumentos semidirectos de la democracia. Al comparar Francia con Estados Unidos con el objetivo de analizar por una parte, cómo las iniciativas populares y los referendums influenciaron la legislación de algunos estados americanos y por otra, cómo los referéndums nacionales en Francia fueron reducidos a plebiscitos, intentamos descifrar si la naturaleza de la democracia semidirecta es el resultado de un resentimiento contra la lentitud del trabajo representativo o si concluye la transformación del gobierno representativo.If the feelings of frustration against the representative system are expressed by populism, it is crucial to question the link between a disappointment vis-à-vis the institutions and the semi-direct democracy instruments. By comparing France and United States in order to analyze on the one hand how popular initiatives and referenda influenced the legislation of some American States and on the other

  13. Factorization of cp-rank-3 completely positive matrices

    Czech Academy of Sciences Publication Activity Database

    Brandts, J.; Křížek, Michal

    2016-01-01

    Roč. 66, č. 3 (2016), s. 955-970 ISSN 0011-4642 R&D Projects: GA ČR GA14-02067S Institutional support: RVO:67985840 Keywords : completely positive matrix * cp-rank * factorization Subject RIV: BA - General Mathematics Impact factor: 0.364, year: 2016 http://hdl.handle.net/10338.dmlcz/145882

  14. What semi-inclusive data say about clusters

    International Nuclear Information System (INIS)

    Arneodo, A.; Plaut, G.

    1976-01-01

    A global analysis of inclusive high-energy multi-particle production data in the cluster model framework is extended to semi-inclusive data. The cluster model embodies leading particle effects and kinematical constraints, which are shown to be of great importance. It appears that models with light clusters decaying on average into approximately equal to 2 charged particles, with a rapidity width delta approximately equal to 0.6 - 0.7 and a distribution much narrower than a Poisson-type, allow one to fit in a nice way both inclusive and semi-inclusive data. It is pointed out that the most constraining semi-inclusive data are those regarding longitudinal correlations, which definitely exclude heavy cluster models, whereas the data on zone characteristics only bear out that a non-negligible percentage of clusters have to carry an electric charge. (Auth.)

  15. 3D super-virtual refraction interferometry

    KAUST Repository

    Lu, Kai

    2014-08-05

    Super-virtual refraction interferometry enhances the signal-to-noise ratio of far-offset refractions. However, when applied to 3D cases, traditional 2D SVI suffers because the stationary positions of the source-receiver pairs might be any place along the recording plane, not just along a receiver line. Moreover, the effect of enhancing the SNR can be limited because of the limitations in the number of survey lines, irregular line geometries, and azimuthal range of arrivals. We have developed a 3D SVI method to overcome these problems. By integrating along the source or receiver lines, the cross-correlation or the convolution result of a trace pair with the source or receiver at the stationary position can be calculated without the requirement of knowing the stationary locations. In addition, the amplitudes of the cross-correlation and convolution results are largely strengthened by integration, which is helpful to further enhance the SNR. In this paper, both synthetic and field data examples are presented, demonstrating that the super-virtual refractions generated by our method have accurate traveltimes and much improved SNR.

  16. Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles

    Energy Technology Data Exchange (ETDEWEB)

    Atweh, Lamya A.; Dodd, Nicholas A.; Krishnamurthy, Ramkumar; Chu, Zili D. [Texas Children' s Hospital, EB Singleton Department of Pediatric Radiology, Cardiovascular Imaging, Houston, TX (United States); Pednekar, Amol [Philips Healthcare, Houston, TX (United States); Krishnamurthy, Rajesh [Texas Children' s Hospital, EB Singleton Department of Pediatric Radiology, Cardiovascular Imaging, Houston, TX (United States); Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Baylor College of Medicine, Department of Pediatrics, Houston, TX (United States)

    2016-05-15

    Breath-held two-dimensional balanced steady-state free precession cine acquisition (2-D breath-held SSFP), accelerated with parallel imaging, is the method of choice for evaluating ventricular function due to its superior blood-to-myocardial contrast, edge definition and high intrinsic signal-to-noise ratio throughout the cardiac cycle. The purpose of this study is to qualitatively and quantitatively compare the two different single-breath-hold 3-D cine SSFP acquisitions using 1) multidirectional sensitivity encoding (SENSE) acceleration factors (3-D multiple SENSE SSFP), and 2) k-t broad-use linear acceleration speed-up technique (3-D k-t SSFP) with the conventional 2-D breath-held SSFP in non-sedated asymptomatic volunteers and children with single ventricle congenital heart disease. Our prospective study was performed on 30 non-sedated subjects (9 healthy volunteers and 21 functional single ventricle patients), ages 12.5 +/- 2.8 years. Two-dimensional breath-held SSFP with SENSE acceleration factor of 2, eight-fold accelerated 3-D k-t SSFP, and 3-D multiple SENSE SSFP with total parallel imaging factor of 4 were performed to evaluate ventricular volumes and mass in the short-axis orientation. Image quality scores (blood myocardial contrast, edge definition and interslice alignment) and volumetric analysis (end systolic volume, end diastolic volume and ejection fraction) were performed on the data sets by experienced users. Paired t-test was performed to compare each of the 3-D k-t SSFP and 3-D multiple SENSE SSFP clinical scores against 2-D breath-held SSFP. Bland-Altman analysis was performed on left ventricle (LV) and single ventricle volumetry. Interobserver and intraobserver variability in volumetric measurements were determined using intraclass coefficients. The clinical scores were highest for the 2-D breath-held SSFP images. Between the two 3-D sequences, 3-D multiple SENSE SSFP performed better than 3-D k-t SSFP. Bland-Altman analysis for volumes

  17. A semi-automatic image-based close range 3D modeling pipeline using a multi-camera configuration.

    Science.gov (United States)

    Rau, Jiann-Yeou; Yeh, Po-Chia

    2012-01-01

    The generation of photo-realistic 3D models is an important task for digital recording of cultural heritage objects. This study proposes an image-based 3D modeling pipeline which takes advantage of a multi-camera configuration and multi-image matching technique that does not require any markers on or around the object. Multiple digital single lens reflex (DSLR) cameras are adopted and fixed with invariant relative orientations. Instead of photo-triangulation after image acquisition, calibration is performed to estimate the exterior orientation parameters of the multi-camera configuration which can be processed fully automatically using coded targets. The calibrated orientation parameters of all cameras are applied to images taken using the same camera configuration. This means that when performing multi-image matching for surface point cloud generation, the orientation parameters will remain the same as the calibrated results, even when the target has changed. Base on this invariant character, the whole 3D modeling pipeline can be performed completely automatically, once the whole system has been calibrated and the software was seamlessly integrated. Several experiments were conducted to prove the feasibility of the proposed system. Images observed include that of a human being, eight Buddhist statues, and a stone sculpture. The results for the stone sculpture, obtained with several multi-camera configurations were compared with a reference model acquired by an ATOS-I 2M active scanner. The best result has an absolute accuracy of 0.26 mm and a relative accuracy of 1:17,333. It demonstrates the feasibility of the proposed low-cost image-based 3D modeling pipeline and its applicability to a large quantity of antiques stored in a museum.

  18. Study of a high-resolution, 3-D positioning cadmium zinc telluride detector for PET

    Science.gov (United States)

    Gu, Y; Matteson, J L; Skelton, R T; Deal, A C; Stephan, E A; Duttweiler, F; Gasaway, T M; Levin, C S

    2011-01-01

    This paper investigates the performance of 1 mm resolution Cadmium Zinc Telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3-D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06±0.39% at 511 keV throughout most the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44±0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78±0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes – as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system. PMID:21335649

  19. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

    Science.gov (United States)

    Gu, Y; Matteson, J L; Skelton, R T; Deal, A C; Stephan, E A; Duttweiler, F; Gasaway, T M; Levin, C S

    2011-03-21

    This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06 ± 0.39% at 511 keV throughout most of the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44 ± 0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78 ± 0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes-as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system.

  20. Metallic and semi-conducting resistivity behaviour of La0.7Ca0.3- x K x MnO3 ( x = 0.05, 0.1) manganites

    Science.gov (United States)

    Varshney, Dinesh; Dodiya, Neha

    2015-12-01

    The temperature dependence of electrical resistivity, ρ, of ceramic La0.7Ca0.3- x K x MnO3 ( x = 0.05, 0.1) is investigated in metallic and semi-conducting phase. The metallic resistivity is attributed to be caused by electron-phonon, electron-electron and electron-magnon scattering. Substitutions affect average mass and ionic radii of A-site resulting in an increase in Debye temperature θ D attributed to hardening of lattice with K doping. The optical phonon modes shift gradually to lower mode frequencies leading to phonon softening. Estimated resistivity compared with reported metallic resistivity, accordingly ρ diff. = [ ρ exp. - { ρ 0 + ρ e-ph (= ρ ac + ρ op)}], infers electron-electron and electron-magnon dependence over most of the temperature range. Semi-conducting nature is discussed with variable range hopping and small polaron conduction model. The decrease in activation energies and increase in density of states at the Fermi level with enhanced Ca doping is consistently explained by cationic disorder and Mn valence.

  1. Neck control after definitive radiochemotherapy without planned neck dissection in node-positive head and neck cancers

    International Nuclear Information System (INIS)

    Jang, Na Young; Lee, Keun-Wook; Ahn, Soon-Hyun; Kim, Jae-Sung; Ah Kim, In

    2012-01-01

    The purpose of this study was to evaluate neck control outcomes after definitive radiochemotherapy without planned neck dissection in node-positive head and neck cancer. We retrospectively reviewed medical records of fifty patients with node-positive head and neck cancer who received definitive radiochemotherapy. Twelve patients subsequently underwent neck dissection for suspicious recurrent or persistent disease. A median dose of 70 Gy (range 60-70.6) was delivered to involved nodes. Response evaluation was performed at a median of 5 weeks after completion of radiotherapy. Neck failure was observed in 11 patients and the 3-year regional control (RC) rate was 77.1%. Neck dissection was performed in 10 of the 11 patients; seven of these cases were successfully salvaged, and the ultimate rate of neck control was 92%. The remaining two patients who received neck dissection had negative pathologic results. On univariate analysis, initial nodal size > 2 cm, a less-than-complete response at the primary site, post-radiotherapy nodal size > 1.5 cm, and post-radiotherapy nodal necrosis were associated with RC. On multivariate analysis, less-than-complete primary site response and post-radiotherapy nodal necrosis were identified as independent prognostic factors for RC. The neck failure rate after definitive radiochemotherapy without planned neck dissection was 22%. Two-thirds of these were successfully salvaged with neck dissection and the ultimate neck control rate was 92%. Our results suggest that planned neck dissection might not be necessary in patients with complete response of primary site, no evidence of residual lesion > 1.5 cm, or no necrotic lymph nodes at the 1-2 months follow-up evaluation after radiotherapy

  2. Comparison of Radiation Treatment Plans for Breast Cancer between 3D Conformal in Prone and Supine Positions in Contrast to VMAT and IMRT Supine Positions

    Science.gov (United States)

    Bejarano Buele, Ana Isabel

    The treatment regimen for breast cancer patients typically involves Whole Breast Irradiation (WBI). The coverage and extent of the radiation treatment is dictated by location of tumor mass, breast tissue distribution, involvement of lymph nodes, and other factors. The current standard treatment approach used at our institution is a 3D tangential beam geometry, which involves two fields irradiating the breast, or a four field beam arrangement covering the whole breast and involved nodes, while decreasing the dose to organs as risk (OARs) such as the lung and heart. The coverage of these targets can be difficult to achieve in patients with unfavorable thoracic geometries, especially in those cases in which the planning target volume (PTV) is extended to the chest wall. It is a well-known fact that exposure of the heart to ionizing radiation has been proved to increase the subsequent rate of ischemic heart disease. In these cases, inverse planned treatments have become a proven alternative to the 3D approach. The goal of this research project is to evaluate the factors that affect our current techniques as well as to adapt the development of inverse modulated techniques for our clinic, in which breast cancer patients are one of the largest populations treated. For this purpose, a dosimetric comparison along with the evaluation of immobilization devices was necessary. Radiation treatment plans were designed and dosimetrically compared for 5 patients in both, supine and prone positions. For 8 patients, VMAT and IMRT plans were created and evaluated in the supine position. Skin flash incorporation for inverse modulated plans required measurement of the surface dose as well as an evaluation of breast volume changes during a treatment course. It was found that prone 3D conformal plans as well as the VMAT and IMRT plans are generally superior in sparing OARs to supine plans with comparable PTV coverage. Prone setup leads to larger shifts in breast volume as well as in

  3. 5 CFR 351.203 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... for a position covered by a wage-board or similar wage-determining procedure, such as provided in the definition of representative rate for Federal Wage System positions in 5 CFR 532.401 of this chapter; (3) For... low priority program or to a vacant position. [51 FR 319, Jan. 3, 1986, as amended at 58 FR 65533, Dec...

  4. Fully digital 1-D, 2-D and 3-D multiscroll chaos as hardware pseudo random number generators

    KAUST Repository

    Mansingka, Abhinav S.

    2012-10-07

    This paper introduces the first fully digital implementation of 1-D, 2-D and 3-D multiscroll chaos using the sawtooth nonlinearity in a 3rd order ODE with the Euler approximation. Systems indicate chaotic behaviour through phase space boundedness and positive Lyapunov exponent. Low-significance bits form a PRNG and pass all tests in the NIST SP. 800-22 suite without post-processing. Real-time control of the number of scrolls allows distinct output streams with 2-D and 3-D multiscroll chaos enabling greater controllability. The proposed PRNGs are experimentally verified on a Xilinx Virtex 4 FPGA with logic utilization less than 1.25%, throughput up to 5.25 Gbits/s and up to 512 distinct output streams with low cross-correlation.

  5. VC and ACIS/HOOPS based semi-physical virtual prototype design and motion simulation of 2D scanning mirror

    Science.gov (United States)

    Liu, Xiangyan; Dai, Xiaobing; He, Xudong; Gao, Pengcheng

    2013-10-01

    Image-spectrum integrated instrument is an infrared scanning system which integrates optics, mechanics, electrics and information processing. Not only can it achieve scene imaging, but also it can detect, track and identify targets of interests in the scene through acquiring their spectra. After having a brief introduction to image-spectrum integrated instrument and analyzing how 2D scanning mirror works, this paper built 3D model of 2D scanning mirror and simulated its motion using two PCs basing on VC++ and ACIS/HOOPS. Two PCs communicate with each other through serial ports. One PC serves as host computer, on which controlling software runs, is responsible for loading image sequence, image processing, target detecting, and generating and sending motion commands to scanning mirror. The other serves as slave computer, on which scanning mirror motion simulation software runs, is responsible for receiving motion commands to control scanning mirror to finish corresponding movements. This method proposed in this paper adopted semi-physical virtual prototype technology and used real scene image sequence to control virtual 2D scanning mirror and simulates motion of real 2D scanning mirror. It has no need for real scanning mirror and is of important practical significance for debugging controlling software of 2D scanning mirror.

  6. 15 CFR 16.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... INFORMATION LABELING PROGRAM § 16.3 Definitions. (a) The term Secretary means the Secretary of Commerce or her designee. (b) The term consumer means the first person who purchases a consumer product for purposes other than resale. (c) The term participant means a manufacturer, assembler or private brand labeler of...

  7. 49 CFR 22.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... Office of the Secretary of Transportation SHORT-TERM LENDING PROGRAM (STLP) General § 22.3 Definitions... transportation-related contract(s), subcontract(s), and/or purchase order(s) that has been pledged as collateral... loan to the borrower. Loan guarantee means the agreement of DOT OSDBU to issue a guarantee of payment...

  8. 12 CFR 231.2 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... ELIGIBILITY FOR FINANCIAL INSTITUTION (REGULATION EE) § 231.2 Definitions. As used in this part, unless the...” contract). (d) Financial market means a market for a financial contract. (e) Gross mark-to-market positions... other person that controls, is controlled by, or is under common control with the person. (c) Financial...

  9. Measuring Visual Closeness of 3-D Models

    KAUST Repository

    Gollaz Morales, Jose Alejandro

    2012-09-01

    Measuring visual closeness of 3-D models is an important issue for different problems and there is still no standardized metric or algorithm to do it. The normal of a surface plays a vital role in the shading of a 3-D object. Motivated by this, we developed two applications to measure visualcloseness, introducing normal difference as a parameter in a weighted metric in Metro’s sampling approach to obtain the maximum and mean distance between 3-D models using 3-D and 6-D correspondence search structures. A visual closeness metric should provide accurate information on what the human observers would perceive as visually close objects. We performed a validation study with a group of people to evaluate the correlation of our metrics with subjective perception. The results were positive since the metrics predicted the subjective rankings more accurately than the Hausdorff distance.

  10. Application of Image Processing Algorithms for Brain Tumor Analysis in 2D and 3D Leading to Tumor’s Positioning in Skull: Overview

    Directory of Open Access Journals (Sweden)

    AYESHA AMIR SIDDIQI

    2017-01-01

    Full Text Available Segmentation of brain tumors has been found challenging throughout in the field of image processing. Different algorithms have been applied to the segmentation of solid or cystic tumors individually but little work has been done for solid cum cystic tumor. The papers reviewed in this article only deal with the case study of patients suffering from solid cum cystic brain tumor as this type of tumor is rarely found for the purpose of research. The research work conducted so far on this topic has been reviewed. The study begins with 2D (Two Dimensional segmentation of tumor using MATLAB. It is then extended to study of slices of tumor and its volume calculation using open source software named 3D Slicer which represents the tumor in 3D. This software can intake the 2D slices and process them to give a combined 3D view. Various techniques are available in the software. According to the particular requirement an appropriate algorithm can be chosen. This paper gives a promising hierarchy for volume calculation of tumor and the three dimensional view. Further we can also find the position of tumor in the skull using the same software. This piece of work is a valuable guideline for the researchers interested in segmentation and three dimensional representations of different areas of human body. The models extracted out using the given algorithms can also be treated for matching and comparison of any future research. This will also aid surgeons and physicians in efficient analysis and reporting techniques.

  11. From GCode to STL: Reconstruct Models from 3D Printing as a Service

    Science.gov (United States)

    Baumann, Felix W.; Schuermann, Martin; Odefey, Ulrich; Pfeil, Markus

    2017-12-01

    The authors present a method to reverse engineer 3D printer specific machine instructions (GCode) to a point cloud representation and then a STL (Stereolithography) file format. GCode is a machine code that is used for 3D printing among other applications, such as CNC routers. Such code files contain instructions for the 3D printer to move and control its actuator, in case of Fused Deposition Modeling (FDM), the printhead that extrudes semi-molten plastics. The reverse engineering method presented here is based on the digital simulation of the extrusion process of FDM type 3D printing. The reconstructed models and pointclouds do not accommodate for hollow structures, such as holes or cavities. The implementation is performed in Python and relies on open source software and libraries, such as Matplotlib and OpenCV. The reconstruction is performed on the model’s extrusion boundary and considers mechanical imprecision. The complete reconstruction mechanism is available as a RESTful (Representational State Transfer) Web service.

  12. The role of three-dimensional high-definition laparoscopic surgery for gynaecology.

    Science.gov (United States)

    Usta, Taner A; Gundogdu, Elif C

    2015-08-01

    This article reviews the potential benefits and disadvantages of new three-dimensional (3D) high-definition laparoscopic surgery for gynaecology. With the new-generation 3D high-definition laparoscopic vision systems (LVSs), operation time and learning period are reduced and procedural error margin is decreased. New-generation 3D high-definition LVSs enable to reduce operation time both for novice and experienced surgeons. Headache, eye fatigue or nausea reported with first-generation systems are not different than two-dimensional (2D) LVSs. The system's being more expensive, having the obligation to wear glasses, big and heavy camera probe in some of the devices are accounted for negative aspects of the system that need to be improved. Depth loss in tissues in 2D LVSs and associated adverse events can be eliminated with 3D high-definition LVSs. By virtue of faster learning curve, shorter operation time, reduced error margin and lack of side-effects reported by surgeons with first-generation systems, 3D LVSs seem to be a strong competition to classical laparoscopic imaging systems. Thanks to technological advancements, using lighter and smaller cameras and monitors without glasses is in the near future.

  13. Refined 3d-3d correspondence

    Energy Technology Data Exchange (ETDEWEB)

    Alday, Luis F.; Genolini, Pietro Benetti; Bullimore, Mathew; Loon, Mark van [Mathematical Institute, University of Oxford, Andrew Wiles Building,Radcliffe Observatory Quarter, Woodstock Road, Oxford, OX2 6GG (United Kingdom)

    2017-04-28

    We explore aspects of the correspondence between Seifert 3-manifolds and 3d N=2 supersymmetric theories with a distinguished abelian flavour symmetry. We give a prescription for computing the squashed three-sphere partition functions of such 3d N=2 theories constructed from boundary conditions and interfaces in a 4d N=2{sup ∗} theory, mirroring the construction of Seifert manifold invariants via Dehn surgery. This is extended to include links in the Seifert manifold by the insertion of supersymmetric Wilson-’t Hooft loops in the 4d N=2{sup ∗} theory. In the presence of a mass parameter for the distinguished flavour symmetry, we recover aspects of refined Chern-Simons theory with complex gauge group, and in particular construct an analytic continuation of the S-matrix of refined Chern-Simons theory.

  14. Pathways for Learning from 3D Technology

    Science.gov (United States)

    Carrier, L. Mark; Rab, Saira S.; Rosen, Larry D.; Vasquez, Ludivina; Cheever, Nancy A.

    2016-01-01

    The purpose of this study was to find out if 3D stereoscopic presentation of information in a movie format changes a viewer's experience of the movie content. Four possible pathways from 3D presentation to memory and learning were considered: a direct connection based on cognitive neuroscience research; a connection through "immersion" in that 3D presentations could provide additional sensorial cues (e.g., depth cues) that lead to a higher sense of being surrounded by the stimulus; a connection through general interest such that 3D presentation increases a viewer’s interest that leads to greater attention paid to the stimulus (e.g., "involvement"); and a connection through discomfort, with the 3D goggles causing discomfort that interferes with involvement and thus with memory. The memories of 396 participants who viewed two-dimensional (2D) or 3D movies at movie theaters in Southern California were tested. Within three days of viewing a movie, participants filled out an online anonymous questionnaire that queried them about their movie content memories, subjective movie-going experiences (including emotional reactions and "presence") and demographic backgrounds. The responses to the questionnaire were subjected to path analyses in which several different links between 3D presentation to memory (and other variables) were explored. The results showed there were no effects of 3D presentation, either directly or indirectly, upon memory. However, the largest effects of 3D presentation were on emotions and immersion, with 3D presentation leading to reduced positive emotions, increased negative emotions and lowered immersion, compared to 2D presentations. PMID:28078331

  15. L-edge sum rule analysis on 3d transition metal sites: from d10 to d0 and towards application to extremely dilute metallo-enzymes.

    Science.gov (United States)

    Wang, Hongxin; Friedrich, Stephan; Li, Lei; Mao, Ziliang; Ge, Pinghua; Balasubramanian, Mahalingam; Patil, Daulat S

    2018-03-28

    According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0 . In addition, extremely dilute (edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d 0 to a closed shell 3d 10 ; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.

  16. A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.

    Science.gov (United States)

    Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M

    To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  17. 3D position readout from thick scintillators

    CERN Document Server

    Antich, P; Parkey, R; Slavin, N V; Tsyganov, E N

    2002-01-01

    A novel technique has been developed and tested for the three-dimensional measurement of position in SPECT-PET detectors. Results are presented for 2 and 20 mm thick NaI(Tl) planar crystals. In a plane of crystal, a coordinate resolution of about 1 mm (rms error) is demonstrated. The depth of interaction (DOI) is measured with an rms error of about 2 mm using light cone parameters.

  18. Analysis of Display Latency for 3D Perceptual Experiments

    Science.gov (United States)

    2016-11-01

    Stereoscopic images were displayed on an LG 55 in. Class (54.6 in. diagonal) cinema 3D 1080p 240 Hz LED TV for stimulus display. The 3D display...were nearly identical to those in Recording 3, where we had the variation in stimulus depth and the randomly sampled ISI times. The camera position

  19. YouDash3D: exploring stereoscopic 3D gaming for 3D movie theaters

    Science.gov (United States)

    Schild, Jonas; Seele, Sven; Masuch, Maic

    2012-03-01

    Along with the success of the digitally revived stereoscopic cinema, events beyond 3D movies become attractive for movie theater operators, i.e. interactive 3D games. In this paper, we present a case that explores possible challenges and solutions for interactive 3D games to be played by a movie theater audience. We analyze the setting and showcase current issues related to lighting and interaction. Our second focus is to provide gameplay mechanics that make special use of stereoscopy, especially depth-based game design. Based on these results, we present YouDash3D, a game prototype that explores public stereoscopic gameplay in a reduced kiosk setup. It features live 3D HD video stream of a professional stereo camera rig rendered in a real-time game scene. We use the effect to place the stereoscopic effigies of players into the digital game. The game showcases how stereoscopic vision can provide for a novel depth-based game mechanic. Projected trigger zones and distributed clusters of the audience video allow for easy adaptation to larger audiences and 3D movie theater gaming.

  20. 3D scan line method for identifying void fabric of granular materials

    Directory of Open Access Journals (Sweden)

    Theocharis Alexandros I.

    2017-01-01

    Full Text Available Among other processes measuring the void phase of porous or fractured media, scan line approach is a simplified “graphical” method, mainly used in image processing related procedures. In soil mechanics, the application of scan line method is related to the soil fabric, which is important in characterizing the anisotropic mechanical response of soils. Void fabric is of particular interest, since graphical approaches are well defined experimentally and most of them can also be easily used in numerical experiments, like the scan line method. This is in contrast to the definition of fabric based on contact normal vectors that are extremely difficult to determine, especially considering physical experiments. The scan line method has been proposed by Oda et al [1] and implemented again by Ghedia and O’Sullivan [2]. A modified method based on DEM analysis instead of image measurements of fabric has been previously proposed and implemented by the authors in a 2D scheme [3-4]. In this work, a 3D extension of the modified scan line definition is presented using PFC 3D®. The results show clearly similar trends with the 2D case and the same behaviour of fabric anisotropy is presented.