WorldWideScience

Sample records for positive mini diagnosis

  1. [Comparison of endotracheal aspiration and mini-BAL culture results in the diagnosis of ventilator-associated pneumonia].

    Science.gov (United States)

    Artuk, Cumhur; Gül, Hanefi Cem; Mert, Gürkan; Karakaş, Ahmet; Bedir, Orhan; Eyigün, Can Polat

    2012-07-01

    The objective of this study was to compare the results of cultures obtained by mini-bronchoalveolar lavage (BAL) and endotracheal aspiration (ETA) techniques, used for rapid and accurate determination of pathogens causing ventilator-associated pneumonia (VAP) in intensive care units. Of the 92 patients on mechanical ventilation followed at the emergency intensive care unit of our hospital between June 2010 and June 2011, 30 (32.2%) patients were diagnosed as VAP and they were included in this study. VAP diagnosis were based on the clinical and radiological findings. Clinical pulmonary infection score (CPIS) of > 6 was accepted as the clinical criteria of VAP. Initially ETA samples were collected from the patients followed by mini-BAL sampling 15 minutes later, together with urine and two blood cultures. Microbiological evaluation and identification were performed by conventional methods and Phoenix 100 (BD Diagnostic Systems, ABD) automated system. In quantitative culture analysis, > 10.000 cfu/ml for BAL and > 100.000 cfu/ml for ETA were accepted as the positive result. The mean ages of VAP-developed (n= 30; 18 were male) and nondeveloped (n= 62; 39 were male) patients were 68.23 ± 16.19 and 52.16 ± 10.41 years, respectively, and the mean durations of mechanical ventilation were 29.57 ± 15.78 and 12.11 ± 6.01 days, respectively. Multivariate logistic regression analysis showed that older age (pVAP development. There was also a statistically significant difference in CPIS values between patients who developed VAP and not (6.8 ± 1.15 and 2.71 ± 1.06, respectively; pVAP diagnosis was found to be useful in patients on mechanical ventilation. In our study, a total of 16 strains (six A.baumannii, three P.aeruginosa, one K.pneumoniae, six S.aureus) were isolated from ETA cultures, while 34 strains (16 A.baumannii, six P.aeruginosa, four K.pneumoniae, two E.coli, six S.aureus) were isolated from mini-BAL cultures of 30 VAP patients. The contamination rate for ETA

  2. [Reliability and validity of the standardized Mini Mental State Examination in the diagnosis of mild dementia in Turkish population].

    Science.gov (United States)

    Güngen, Can; Ertan, Turan; Eker, Engin; Yaşar, Resmiye; Engin, Funda

    2002-01-01

    Reliability and validity of the Mini Mental State Examination in differentiating mild dementia from normal controls in Turkish population. The Standardized Mini Mental State Examination (SMMSE) and its instruction were translated into Turkish. A total of 212 subjects with mean age of 77 +/- 6, were recruited for the study. 71 were diagnosed to be demented and 141 were evaluated as normal controls. The scale total score was analysed for discriminant validity using Student's t-test. Sensitivity, specificity, positive and negative predictive values and kappa score were calculated for all of the scores between 18 and 29. Kappa value was calculated for the comparison of the dementia diagnosis between the two investigators using the best cut off score obtained in the analysis above. Statistical analysis revealed that the Turkish version of the SMMSE has high discriminant validity and interrater reliability in the diagnosis of mild dementia. The cut off score 23/24 was found to have the highest sensitivity (0.91), specificity (0.95), positive and negative predictive values (0.90 and 0.95) and kappa score (0.86). Interrater reliability analysis showed high correlation (r:0.99) and kappa value (0.92). The results of this study showed that the Turkish version of the SMMSE has high reliability and validity for the diagnosis of mild dementia in Turkish population.

  3. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  4. Mini-FLOTAC, an innovative direct diagnostic technique for intestinal parasitic infections: experience from the field.

    Science.gov (United States)

    Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco

    2013-01-01

    Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.

  5. [Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)].

    Science.gov (United States)

    D'El Rey, Gustavo José Fonseca; Matos, Cláudia Wilmor

    2009-01-01

    Social phobia (also known as social anxiety disorder) is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN) in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426) of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version) demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive value of 98.6% and incorrect classification rate of 16.9%. With score of 7 points, was observed an increase in the specificity and positive predictive value (88.6% and 62.7%), while the sensitivity and negative predictive value (84.8% and 96.2%) remained high. The Portuguese version of the Mini-SPIN showed satisfactory psychometric qualities in terms of discriminative validity. In this study, the cut-off of 7, was considered to be the most suitable to screening of the generalized social phobia.

  6. Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study

    Directory of Open Access Journals (Sweden)

    Zohreh Hedayati

    2016-10-01

    Full Text Available Abstract Background Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. Methods A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. Results Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. Conclusions According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition.

  7. Detection of dementia in primary care: comparison of the original and a modified Mini-Cog Assessment with the Mini-Mental State Examination.

    Science.gov (United States)

    Kamenski, Gustav; Dorner, Thomas; Lawrence, Kitty; Psota, Georg; Rieder, Anita; Schwarz, Franz; Sepandj, Asita; Spiegel, Wolfgang; Strotzka, Stefan

    2009-12-01

    Background Dementia is considered widely under-detected in primary care, and general practitioners (GPs) frequently ask for easy to use tools to assist in its early detection.Aim To determine the degree of correlation between the Mini-Cog Assessment (Mini-Cog) as performed by GPs and the Mini-Mental State Examination (MMSE).Design of study This was a prospective study (2005, 2006) comparing two cognitive screening instruments.Setting Ten general practices in Austria, with patients with a hitherto undiagnosed suspicion of dementia seen consecutively.Method Sensitivity, specificity and positive and negative predictive values (PPVs and NPVs) of the Mini-Cog (applying both a colour-coded and the original rating method) were assessed for degree of correlation with the MMSE. In phase one GPs examined patients suspected of having dementia using the Mini-Cog; in phase two a neurologist retested them applying the MMSE, a clock-drawing test (CDT) and a routine clinical examination. A questionnaire on the practicability of the Mini-Cog was answered by GPs.Results Of the 107 patients who participated 86 completed the whole study protocol. The Mini-Cog, as performed by the ten GPs, displayed a sensitivity of 0.85 (95% CI: 0.71, 0.98), a specificity of 0.58 (95% CI: 0.46, 0.71), a PPV of 0.47 (95% CI: 0.33, 0.61) and an NPV of 0.90 (95% CI: 0.80, 0.99) as against the MMSE carried out by neurologists. The GPs judged the Mini-Cog useful and time saving.Conclusion The Mini-Cog has a high sensitivity and acceptable specificity in the general practice setting and has proved to be a practicable tool for the diagnosis of dementia in primary care.

  8. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    Science.gov (United States)

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Validity of a short clinical interview for psychiatric diagnosis: the mini-SCAN.

    Science.gov (United States)

    Nienhuis, F J; van de Willige, G; Rijnders, C A Th; de Jonge, P; Wiersma, D

    2010-01-01

    To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. To establish the validity and practical properties of the mini-SCAN. One hundred and six participants were interviewed twice, once with the SCAN and once with the mini-SCAN. The level of agreement was established for the categories: no disorder, affective disorders, anxiety disorders, non-affective psychotic disorders, affective psychotic disorders. The mini-SCAN is a valid instrument. Most kappa values were around 0.90. Only for the class of affective psychotic disorders was the agreement moderate. Mean duration of the mini-SCAN interviews was 25 min shorter than the SCAN interviews. Participants and interviewers were generally satisfied with the interview format and questions. The mini-SCAN can be used as a diagnostic instrument for clinical purposes and for clinical studies when the present episode is the focus of attention.

  10. Mini-mental Parkinson (MMP) as a dementia screening test: comparison with the Mini-Mental State Examination (MMSE).

    Science.gov (United States)

    Larner, Andrew J

    2012-07-01

    As populations age, screening instruments for cognitive impairment and dementia will become of increasing importance in clinical practice. Mini-Mental Parkinson (MMP), a derivative of the Mini-Mental State Examination (MMSE), was originally described as a cognitive screening instrument for use in Parkinson's disease. Its item content addresses some of the acknowledged shortcomings of the MMSE. Pragmatic use of MMP in general cognitive clinics has not previously been examined. To compare the performance of two scales, Mini-Mental Parkinson (MMP) and the Mini-Mental State Examination (MMSE), as cognitive screening instruments for dementia in a memory clinic population. MMP was administered prospectively to 201 consecutive new patient referrals independent of other tests used to establish dementia diagnosis according to standard diagnostic criteria (DSM-IV). Diagnostic utility of MMP for dementia was measured and compared with MMSE. MMP proved easy to use and acceptable to patients. Optimal test accuracy (0.86) was at MMP cutoff of ≤ 17/32, with sensitivity 0.51, specificity 0.97, positive predictive value 0.83, negative predictive value 0.87, and area under Receiver Operating Characteristic curve 0.89. Using a higher cutoff (≤ 29/32), MMP sensitivity was 1.00 with specificity 0.70. MMP scores correlated with MMSE (r = 0.93) and diagnostic agreement was high (κ = 0.85). MMP is a useful screening instrument in the memory clinic setting, with patients who fall below the designated cutoff requiring further investigation to ascertain a cause for their cognitive impairment.

  11. Standardization of the Korean version of Mini-Mental Adjustment to Cancer (K-Mini-MAC) scale: factor structure, reliability and validity.

    Science.gov (United States)

    Kang, Jee In; Chung, Hyun Cheol; Kim, Se Joo; Choi, Hye Jin; Ahn, Joong Bae; Jeung, Hei-Cheul; Namkoong, Kee

    2008-06-01

    Mental adjustment and coping affect the physical outcome and survival as well as quality of life in cancer patients. The Mini-Mental Adjustment to Cancer (Mini-MAC) scale is a new refined, economical and reliable self-rating instrument measuring cognitive and behavioral responses to cancer. The aim of this study was to evaluate the psychometric properties of the Mini-MAC in Korean cancer patients. A total of 208 cancer patients recruited from the Yonsei Cancer Center were assessed with the Mini-MAC and the Hospital Anxiety and Depression Scale (HADS). Principal component analysis with varimax rotation for the Korean version of Mini-MAC (K-Mini-MAC) confirmed four factors. Three had psychometric properties similar to Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) of the original Mini-MAC. A novel factor, named Positive Attitude, included items of both Fatalism (FA) and Fighting Spirit (FS) from the original version. The five subscales from the original version (AP, HH, FS, FA and CA) and Positive Attitude had acceptable internal reliabilities in our sample (Cronbach's alpha coefficient 0.50-0.86; correlation coefficient of test-retest 0.68-0.88). For the validity, significant interscale correlation was observed in the original five subscales and Positive Attitude. Each subscale including Positive Attitude was also significantly related to Depression and Anxiety of HADS. As a whole, the K-Mini-MAC was a reliable, valid and acceptable tool for Korean cancer patients. These findings can provide information about the cross-cultural validity of Mini-MAC scale's factor structure. Cultural differences were also discussed.

  12. Validity of a short clinical interview for psychiatric diagnosis : the mini-SCAN

    NARCIS (Netherlands)

    Nienhuis, F. J.; van de Willige, G.; Rijnders, C. A. Th.; de Jonge, P.; Wiersma, D.

    Background To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. Aims To establish the validity and practical properties of the mini-SCAN. Method One hundred

  13. Tourette Syndrome: A Mini-Review

    Directory of Open Access Journals (Sweden)

    Michal Novotny

    2018-03-01

    Full Text Available The purpose of this mini-review is to provide the latest information on epidemiology, pathophysiology, diagnosis, and treatment of Tourette syndrome (TS. The authors conducted a literature search of available sources describing the issue of tic disorders with special focus on TS and made a comparison and evaluation of relevant findings. The results of this mini-review indicate that TS is a complex disorder, which has a significant impact on the quality of life of both the patients and his/her family. Therefore, early and proper diagnosis and treatment are necessary in order to reduce or even eliminate both symptoms and social burden of the patient. This requires a multidisciplinary management approach in order to meet the patients’ special needs. Future research should focus on neuroimaging, new neurotransmitter targets, in functional neurosurgery, as well as the effect of non-pharmacological psychotherapies for these people.

  14. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo José Fonseca D'El Rey

    2009-12-01

    Full Text Available A fobia social (também conhecida como transtorno de ansiedade social é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426 de um estudo de prevalência de transtornos de ansiedade na cidade de Santo André (SP. A versão em português do Mini-SPIN (com escore de 6 pontos, sugerido na versão original em inglês demonstrou uma sensibilidade de 95,0%, especificidade de 80,3%, valor preditivo positivo de 52,8%, valor preditivo negativo de 98,6% e taxa de classificação incorreta de 16,9%. Com escores de 7 pontos, foi observado um aumento na especificidade e no valor preditivo positivo (88,6% e 62,7%, sendo que a sensibilidade e o valor preditivo negativo (84,8% e 96,2% mantiveram-se altos. A versão em português do Mini-SPIN apresentou qualidades psicométricas satisfatórias em termos de validade discriminativa. Neste estudo, o ponto de corte igual a 7 mostrou-se mais adequado para a identificação da fobia social generalizada.Social phobia (also known as social anxiety disorder is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426 of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive

  15. Detection of EpCAM-positive microparticles in pleural fluid: A new approach to mini-invasively identify patients with malignant pleural effusions.

    Science.gov (United States)

    Roca, Elisa; Lacroix, Romaric; Judicone, Coralie; Laroumagne, Sophie; Robert, Stéphane; Cointe, Sylvie; Muller, Alexandre; Kaspi, Elise; Roll, Patrice; Brisson, Alain R; Tantucci, Claudio; Astoul, Philippe; Dignat-George, Françoise

    2016-01-19

    Pleural biomarkers allowing to mini-invasively discriminate benign from malignant pleural effusions are needed. Among potential candidates, microparticles (MPs) are extracellular vesicles that vectorize antigen derived from the parent cell. We hypothesized that tumor-derived MPs could be present in the pleural liquid and help to identify patients with malignant pleural effusions. Using highly sensitive flow cytometry and cryo-electron microscopy, we showed that large amounts of MPs from hematopoïetic and vascular origin could be detectable in pleural fluids. Their level did not differ between benign (n = 14) and malignant (n = 71) pleural effusions. Analysis of selected tumoral associated antigens (podoplanin, mucin 1 and EpCAM, epithelial-cell-adhesion-molecule) evidenced for the first time the presence of tumor-derived MPs expressing EpCAM in malignant pleural fluids only (Specificity = 93%, Sensitivity = 49% and 45% for flow cytometry and ELISA, respectively). The detection of EpCAM-positive-MPs (EpCAM + MPs) by flow cytometry showed a better specificity and sensitivity than ELISA to distinguish between pleural carcinoma and the others malignant pleural effusions (MPE; Sp: 96% vs 89%; Se: 79% vs 66%). Combining EpCAM+ MPs and cytology improved the diagnosis of MPE compared to cytology alone. This study establishes the basis for using EpCAM+ MPs as a promising new biomarker that could be added to the armamentarium to mini-invasively identify patients with malignant pleural effusions.

  16. Mini-hydropower development in human province of China and its position in the national economy

    International Nuclear Information System (INIS)

    Daogao, L.

    1991-01-01

    Hunan province is situated in the southern part of the middle reaches of Yangtze River. With a population of 61 million, it covers an area of about 211,800 km 2 , equivalent to forty percents of the territorial area of France. Throughout the province, there are more than 5300 rivers and 13000 reservoirs completed before 1991, of which over 7300 mini-hydropower stations are under operation. The theoretical hydropower potential is 15320 MW among them 12990 MW can be exploited with a total installed capacity of 1320 MW and an annual generation output of 4150 GWh. The paper will describe the general condition of the hydropower resources, development of mini-hydropower in Human province and its positive role in the national economy. Additionally, the standard of classification, the type of equipment for the medium and small-sized hydropower plants and market conditions in Hunan will be also involved in the paper. 5 tabs

  17. Movimentação de molares inferiores ancorados em mini-parafusos Mandibular molar uprighting, using mini-screw as anchorage

    Directory of Open Access Journals (Sweden)

    Rosana Canteras Di Matteo

    2005-08-01

    Full Text Available Freqüentemente a movimentação ortodôntica exige recursos adicionais de ancoragem. Os mini-parafusos têm-se apresentado como uma possível solução. O propósito deste trabalho foi estabelecer um método para a verticalização de molares inferiores inclinados para mesial, utilizando ancoragem em mini-parafusos colocados na região de linha oblíqüa externa da mandíbula. Foram selecionados três pacientes entre 40 a 48 anos (dois do gênero feminino, um do gênero masculino, com molares inferiores inclinados para mesial e distalmente posicionados às áreas edêntulas. Os pacientes foram tratados ortodonticamente durante um período de 6 a 12 meses, com técnica ortodôntica MD3. Mini-parafusos de titânio foram colocados bilateralmente com anestesia local. Uma incisão sobre a linha oblíqüa externa da mandíbula, medindo aproximadamente 1 cm foi realizada em cada lado, distalmente aos molares inclinados. Após descolamento muco-periosteal, mini-parafusos foram implantados e foram realizadas suturas deixando suas cabeças exteriorizadas. Uma semana após a remoção das suturas, cargas ortodônticas (entre 150 a 200 gramas/força foram aplicadas através de forças elásticas. Verificamos que alguma inflamação foi observada ao redor dos mini-parafusos, mas foi controlada com procedimentos de higienização. O procedimento cirúrgico é simples, podendo ser realizado pelo ortodontista; as formas dimensionais dos mini-parafusos são adequadas e estes são de fácil remoção após uso. Concluímos que o uso de mini-parafusos representa uma alternativa efetiva de ancoragem ortodôntica na verticalização de molares inferiores.Tooth movement frequently requires additional anchorage resources. Mini-screws have been used as a possible solution to this matter. The purpose of this study was to establish a method of mandibular molar uprighting, using mini-screw as anchorage, positioned on the mandibular external oblique line, behind and

  18. Reliability of an anamnestic questionnaire for the diagnosis of benign paroxysmal positional vertigo in the elderly.

    Science.gov (United States)

    Lapenna, Ruggero; Faralli, Mario; Del Zompo, Maria Rita; Cipriani, Laura; Mobaraki, Puya Dehgani; Ricci, Giampietro

    2016-10-01

    There is common agreement in the literature that it can result in an underestimation of benign paroxysmal positional vertigo (BPPV) in the elderly. The aim of this work was to analyze the role of anamnesis in the diagnosis of BPPV in patients of different ages through the development and validation of a scored questionnaire. The questionnaire is based on the presence/absence of six typical anamnestic features of BPPV. The Mini-Mental State Exam (MMS) was also administered to patients over 65 years of age. Bedsides, examination for BPPV was then carried out, assigning the outcome of the questionnaire and eventual MMS to the final diagnosis for each patient. The sensitivity and specificity of the questionnaire for high scores (>8) were found to be, respectively, 86 % and 80 % in all patients, 94 and 71 % in those under 65 years of age, 78 and 90 % in patients over 65, and, in particular, 63 and 83 % in those with MMS >24 and 100 and 100 % in those with MMS ≤24. The reliability and average score of the questionnaire were statistically significantly lower in the group of elderly patients without cognitive deficits. The lower reliability of the questionnaire in the geriatric population, rather than the presence of cognitive deterioration, seems to correlate with other comorbidities or simply to a lower mobility of the head triggering positional symptoms. The use of the questionnaire could however reduce the risk of a missed diagnosis of BPPV given its good reliability across all ages.

  19. Supine or prone position for mini-PNL procedure: does it matter.

    Science.gov (United States)

    Tokatlı, Zafer; Gokce, Mehmet Ilker; Süer, Evren; Sağlam, Remzi

    2015-06-01

    In this study it is aimed to compare the success and complication rates of mini-PNL procedure in supine and prone positions. In this retrospective study data of 180 patients treated with MPNL either in supine (n = 54) or prone (n = 126) positions between May 2009 and August 2014 was investigated. Success was defined as no visible stones >2 mm. Perioperative complications were classified using the modified Clavien system. Groups were compared with Chi square test or Student t test and for statistical significance p value of 0.05 was accepted. Mean age of the population was 42.5 ± 8.2 years and mean stone size was 23.9 ± 4.1 mm. The two groups were similar with regard to demographic characteristics and stone related characteristics except the ASA status. Success rates of the supine and prone groups were 85.1 and 87.3%, respectively (p = 0.701). No statistically significant differences in terms of complications were observed. Mean operative time was the only parameter different between the two groups (55 vs 82 min, p = 0.001). Supine position for PNL seems to be promising and the complication and success rates are shown to be similar to the prone position with MPNL technique. The only significant benefit of this technique is shorter operative time.

  20. Mini-FLOTAC and Kato-Katz: helminth eggs watching on the shore of Lake Victoria.

    Science.gov (United States)

    Barda, Beatrice; Zepherine, Henry; Rinaldi, Laura; Cringoli, Giuseppe; Burioni, Roberto; Clementi, Massimo; Albonico, Marco

    2013-07-31

    One of the challenges for monitoring helminth control programmes based on preventive chemotherapy is the lack of a copro-parasitological gold-standard method that combines good sensitivity with quantitative performance, low cost, and easy-to-learn technique.The aim of our study was to evaluate and compare, the WHO recommended quantitative diagnostic technique (Kato-Katz) and the Mini-FLOTAC. Mini-FLOTAC is an innovative method based on floatation of helminths eggs with two different solutions (FS2 and FS7) using a close system (Fill-FLOTAC) with 5% fixative. Kato-Katz was performed following WHO recommendation. The study was carried out in a rural part of Tanzania, close to Lake Victoria, where the laboratory facilities are fairly scarce, and the basic technique used in the local laboratory (direct smear) was taken as reference standard. 201 children were screened for intestinal helminths and 91% of them were found to be positive. The agreement among the three techniques was calculated with k Cohen coefficient and was fairly good (k = 0.4), although the Mini-FLOTAC results were more sensitive for hookworm (98%) with FS2, and for S.mansoni (90%) with FS7 followed by Kato-Katz (91% and 60% respectively) and direct smear (30% and 10% respectively). A good agreement was found between Mini-FLOTAC and Kato-Katz (k = 0.81) with FS7 (k = 0.76) for hookworm diagnosis and a fairly good one for S.mansoni diagnosis (k = 0.5). For both infections we had a poor agreement between the two quantitative techniques and the direct smear (kMcMaster) and in different settings where other soil-transmitted helminths are also endemic.

  1. Validity and applicability of the Mini International Neuropsychiatric Interview administered by family medicine residents in primary health care in Brazil.

    Science.gov (United States)

    de Azevedo Marques, João Mazzoncini; Zuardi, Antonio W

    2008-01-01

    To evaluate the validity and applicability of the Mini International Neuropsychiatric Interview (MINI) used by family medicine residents in primary health care (PHC) in Brazil. Training for administrating the MINI was given as part of a broad psychiatry education program. Interviews were held with 120 PHC patients who were at least 15 years old. MINI was administered by 25 resident physicians, while the Structured Clinical Interview for Diagnosis (SCID) was administered by a psychiatrist blind to patients' results on the MINI, and the diagnoses on both interviews were compared. The resident physicians answered questions on the applicability of the MINI. Concordance levels for any mental disorder, the broader current diagnostic categories and the most common specific diagnoses were analyzed. Kappa coefficients ranged between 0.65 and 0.85; sensitivity, between 0.75 and 0.92; specificity, between 0.90 and 0.99; positive predictive values (PPV), between 0.60 and 0.86; negative predictive values (NPV), between 0.92 and 0.99; and accuracy, between 0.88 and 0.98. The resident physicians considered MINI comprehensibility and clinical relevance satisfactory. These good psychometric results in a real-world setting may be related to a special training program, which is more frequent, intensive and diversified. In these conditions, the MINI is a useful tool for general practitioners.

  2. Evaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT

    International Nuclear Information System (INIS)

    Ishii, Takenobu; Nojima, Kunihiko; Nishii, Yasushi; Takaki, Takashi; Yamaguchi, Hideharu

    2004-01-01

    The interalveolar septum between the upper first molar and the second premolar of the separated human maxillary bone was three-dimensionally observed by micro CT to evaluate the appropriate mini-screw type implant placement position by considering the relationship between the tooth roots and the maxillary sinus. After taking micro CTs of 5 human maxillary bones, horizontally sectioned images of the interalveolar septum area 2, 4, 6, 8, 10, and 12 mm deep from the crest of the alveolar ridge were reconstructed by three-dimensional reconstruction software. The bucco-lingual and mesio-distal lengths and area in each sectioned interalveolar septum were measured using digital image measurement software. Using the results, the interalveolar septum area between the upper first molar and the second premolar approximately 6-8 mm deep from the alveolar crest in the tooth root apical direction was determined to be the safest position for mini-screw implantation. Furthermore, lateral implantation from the palatal side was deduced to be the safest approach. (author)

  3. [Positioning diagnosis of benign positional paroxysmal vertigo by VNG].

    Science.gov (United States)

    Wang, Na; Chen, Taisheng; Lin, Peng; Song, Wei; Dong, Hong

    2009-07-01

    To analyze the value of positioning diagnosis of VNG (Videonystagmograph) in patients with benign paroxysmal positional vertigo (BPPV). One hundred and twenty-six patients with BPPV were enrolled in this retrospective study. Their positional nystagmus recorded by VNG in Dix-Hallpike and roll tests were analyzed to summarize the characteristics of nystagmus on nystagmography of various BPPV. Of 126 patients with BPPV diagnosed in our center, the posterior semicircular canals (PSC) were involved in 98 patients (77.8%), whereas the horizontal semicircular canal (HSC) and anterior semicircular canal (ASC) were involved in 17 (13.5%) and 5 (3.9%), respectively. Six patients (4.8%) confirmed combined-BPPV had HSC-BPPV and ipsilateral PSC-BPPV. Twenty-eight patients with PSC-BPPV had reversal phase on nystagmography. The nystagmus of patients with P/ASC-canalithiasis showed upward/downward on the vertical phase of nystagmography and orientated the opposite side on horizontal phase in the head hanging position, and the nystagmus reversed when returned to sit. Nystagmus on horizontal phase could be provoked when the head turned to both sides of the roll tests in patients with HSC-BPPV. If the nystagmus and the head-turning shared the same direction, then HSC-canalithiasis was confirmed, and the direction of the head-turning which provoked the stronger nystagmus indicates the lesion side. If the nystagmus and the head-turning had the opposite direction, then HSC-cupulolithiasis was confirmed, and the direction of the head-turning which provoked the weaker nystagmus indicates the lesion side. Positional nystagmus can be recorded objectively using VNG, According to which positioning the semicircular canal involved would be easier and more accurate. The recording conserved also could be helpful for clinical diagnosis and repositioning of BPPV.

  4. Initial validation of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale: study of Portuguese end-of-life cancer patients.

    Science.gov (United States)

    Pereira, Filomena Moreira Pinto; Santos, Célia Samarina Vilaça de Brito

    2014-10-01

    The Mini-Mental Adjustment to Cancer Scale (Mini-MAC) is a 29-item instrument designed to evaluate the responses developed by cancer patients during their mental adjustment to diagnosis and treatment. This study aims to validate the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) translated and adapted to the Portuguese language and culture, in end-of-life cancer patients receiving palliative care. The instrument was administered to 346 Portuguese end-of-life cancer patients, receiving care through outpatient visits or admitted into palliative care units, without cognitive symptoms and with symptoms under control. A cross-sectional validation study using orthogonal rotation through the varimax method followed by convergent and discriminant validity. The analysis of the main components confirms the existence of five factors, demonstrating the validity of the construct, with good internal consistency in the subscales and Cronbach's alpha values between 0.78 and 0.93. Good test-retest reliability was also found, and r values for subscales ranged from 0.62 to 0.99. The instrument proved to be a reliable, valid and sensitive measure in the study of mental adjustment of Portuguese end-of-life patients with cancer receiving palliative care. Nurses can use the Mini-MAC Scale in research and clinical practice in order to evaluate the mental adjustment of Portuguese end-of-life cancer patients receiving palliative care. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Diagnosis and Treatment of Benign Paroxysmal Positional Vertigo

    Directory of Open Access Journals (Sweden)

    Muhammed Dagkiran

    2015-12-01

    Full Text Available Benign paroxysmal positional vertigo is the cause of peripheral vertigo, which only takes seconds posed by certain head and body position and led to severe attacks of vertigo. Therefore, it is a disturbance that causes a continuous fear of fall and anxiety in some patients. Although benign paroxysmal positional vertigo is the most common cause of peripheral vertigo, it may cause unnecessary tests, treatment costs and the loss of labor due to the result of the delay in the diagnosis and treatment stages. Diagnosis and treatment of this disease is easy. High success rates can be achieved with appropriate repositioning maneuvers after taking a detailed medical history and accurate assessment of accompanying nystagmus. The aim of this paper was to review the updated information about benign paroxysmal positional vertigo. [Archives Medical Review Journal 2015; 24(4.000: 555-564

  6. Validity and Reliability of the Arabic Version of the Positive and Negative Syndrome Scale.

    Science.gov (United States)

    Yehya, Arij; Ghuloum, Suhaila; Mahfoud, Ziyad; Opler, Mark; Khan, Anzalee; Hammoudeh, Samer; Abdulhakam, Abdulmoneim; Al-Mujalli, Azza; Hani, Yahya; Elsherbiny, Reem; Al-Amin, Hassen

    The Positive and Negative Syndrome Scale (PANSS) is widely used for patients with schizophrenia. This scale is reliable and valid. The PANSS was translated and validated in several languages. The aim of this study was to translate and validate the PANSS in the Arab population. The PANSS was translated into formal Arabic language using the back-translation method. 101 Arab patients with schizophrenia and 98 Arabs with no diagnosis of any mental disorder were recruited. The Arabic version of the Mini International Neuropsychiatric Interview (MINI-6) was used as a diagnostic tool to confirm the diagnosis of schizophrenia or rule out any diagnosis for the healthy control group. Reliability of the scale was assessed by calculating internal consistency, interrater reliability and test-retest reliability. Construct validity was assessed using the Arabic version of the MINI-6. PANSS total scores were correlated with the Clinical Global Impression-Severity scale. Our findings showed that the internal consistency was good (0.92). Scores on the PANSS of the patients were much higher than those of the healthy controls. The PANSS showed good interrater reliability and test-retest reliability (0.92 and 0.75, respectively). In comparison with the MINI-6, the PANSS showed good sensitivity and specificity, which implies good construct validity of this version. In conclusion, the Arabic version of the PANSS is a reliable and valid instrument for the assessment of patients with schizophrenia in the Arab population. © 2016 S. Karger AG, Basel.

  7. Use of days of the week in a modified mini-mental state exam (M-MMSE) for detecting geriatric cognitive impairment.

    Science.gov (United States)

    Hamrick, Irene; Hafiz, Razia; Cummings, Doyle M

    2013-01-01

    The purpose of this study was to compare a modified version of the Mini-Mental State Examination (MMSE) with the standard MMSE and the Mini-Cog in patients ≥65 years old, stratified by education and literacy level. This cross-sectional exploratory study enrolled a convenience sample of 219 patients with a complaint of memory loss or a diagnosis of dementia from a geriatric outpatient clinic, nursing home, senior center, and university hospital. The MMSE was administered, and in addition to spelling and serial 7s backward, patients were asked to recite the days of the week backward with the intent to reduce educational bias. Scores on the modified MMSE were compared with scores of the MMSE and the Mini-Cog. Of the 219 patients, 157 were identified with cognitive impairment by the Mini-Cog. Using a cutoff of ≤23, the MMSE identified 118 patients and the modified MMSE identified 91 patients with cognitive impairment, and with a cutoff of ≤27 the MMSE identified 168 and the modified MMSE 149 patients. All cognitively intact subjects correctly recited the days of the week backward. Specificity of the modified MMSE was higher than the MMSE for most groups. The highest sensitivity and specificity (94% and 88%, respectively) as well as positive and negative predictive values (96% and 81%, respectively) were in patients with low levels of education for the modified MMSE using a cut off of ≤27. Using the days of the week in the MMSE among illiterate and semiliterate participants and with education less than high school, and using a cutoff of 27 of 30, correlates better with Mini-Cog for dementia screening, with fewer false positives.

  8. Role of mini-scleral lens in mucous membrane pemphigoid

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2017-01-01

    Full Text Available This study aims to report the use of mini-scleral contact lens in the management of mucous membrane pemphigoid (MMP with persistent epithelial defects. A 68-year-old male with a history of ocular pain and declining visual acuity was referred to our clinic with a diagnosis of MMP. His corrected distance visual acuity (CDVA was 20/200 in the right eye and 20/100 in the left eye. Despite being on lubricants, topical steroids and intravenous cyclophosphamide, the patient developed persistent corneal epithelial defects in both eyes. He was then given a trial of mini-scleral lenses. Within 4 weeks, corneal epithelial defects healed, and at 6 months, the CDVA had improved to 20/50 in the right eye and 20/40 in the left eye. By improving the corneal surface integrity and visual function, mini-scleral lenses can play a role in the visual rehabilitation of patients with MMP.

  9. A mini-UAV VTOL Platform for Surveying Applications

    Directory of Open Access Journals (Sweden)

    Kuldeep Rawat

    2014-05-01

    Full Text Available In this paper we discuss implementation of a mini-Unmanned Aerial Vehicle (UAV vertical take-off and landing (VTOL platform for surveying activities related to highway construction. Recent advances in sensor and communication technologies have allowed scaling sizes of unmanned aerial platforms, and explore them for tasks that are economical and safe over populated or inhabited areas. In highway construction the capability of mini-UAVs to survey in hostile and/or hardly accessible areas can greatly reduce human risks. The project focused on developing a cost effective, remotely controlled, fuel powered mini-UAV VTOL (helicopter platform with certain payload capacity and configuration and demonstrated its use in surveying and monitoring activities required for highway planning and construction. With an on-board flight recorder global positioning system (GPS device, memory storage card, telemetry, inertial navigation sensors, and a video camera the mini-UAV can record flying coordinates and relay live video images to a remote ground receiver and surveyor. After all necessary integration and flight tests were done the mini-UAV helicopter was tested to operate and relay video from the areas where construction was underway. The mini-UAV can provide a platform for a range of sensors and instruments that directly support the operational requirements of transportation sector.

  10. [Mini-Mental State Examination: Screening and Diagnosis of Cognitive Decline, Using New Normative Data].

    Science.gov (United States)

    Santana, Isabel; Duro, Diana; Lemos, Raquel; Costa, Vanessa; Pereira, Miguel; Simões, Mário R; Freitas, Sandra

    2016-04-01

    The Mini-Mental State Examination is the most commonly used cognitive screening test. In Portugal, the cut-off scores are defined according to literacy groups, but different proposals have been recommended by more representative studies. We therefore propose to confirm the influence of demographical variables, such as age and education, in the subjectâs performance; evaluating the discriminant ability of the new normative data; and to further examine the diagnostic acuity of the validated cut-off scoring for mild cognitive impairment and for the most prevalent types of dementia. Our study includes 1 441 educated subjects, divided into seven subgroups: Mild cognitive impairment, Alzheimer's disease, frontotemporal dementia, vascular dementia, dementia with Lewy bodies, community-controls and memory clinic-controls. Altogether age and education explain 10.4% of the Mini-Mental State Examination results variance, with both variables contributing significantly to the resultsâ prediction. The diagnostic acuity based on the most recent normative data was always higher than the one obtained through the validation cut-off scoring, revealing an overall excellent specificity (superior to 90%) and different sensitivity values: excellent for mild Alzheimer's disease (91%), good for dementia with Lewy Bodies (78%) and low for mild cognitive impairment (65%), frontotemporal dementia and vascular dementia (55%). The performance on the Mini-Mental State Examination is influenced by age and education, supporting the use of normative data that consider those variables. With this approach, the Mini-Mental State Examination could be a sensitive and specific instrument for the Alzheimer's disease screening among all healthcare levels. Nevertheless, its diagnostic acuity is limited in other conditions frequently seen in memory clinics, such as Mild Cognitive Impairment and other types of dementia.

  11. Screening for Dementia in Older Adults: Comparison of Mini-Mental State Examination, Mini-Cog, Clock Drawing Test and AD8.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin

    2016-01-01

    This study was conducted to estimate screening performance of dementia screening tools including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) for older adults. 2015 participants aged 65 years or more in eastern China were enrolled. 4 screening tests were administered and scored by specifically trained psychiatrists. We used data from two-by-two tables to calculate the sensitivity, specificity, and positive and negative predictive values (PPV/NPV). Our study showed that dementia was highly prevalent among elderly in Zhejiang province. The Mini-Cog, with excellent screening characteristics and spending less time, could be considered to be used as a screening tool among communities to help to diagnose dementia early.

  12. The BaBar Mini

    International Nuclear Information System (INIS)

    Brown, David N.

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  13. The BaBar mini

    International Nuclear Information System (INIS)

    Brown, David N.; BaBar Collaboration

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  14. The Galactic Centre Mini-Spiral with CARMA

    Science.gov (United States)

    Kunneriath, D.; Eckart, A.; Vogel, S. N.; Teuben, P.; Muzic, K.; Schodel. R.; Garcia-Marin, M.; Moultaka, J.; Staguhn, J.; Straubmeier, C.; hide

    2012-01-01

    The Galactic centre mini-spiral region is a mixture of gas and dust with temperatures ranging from a few hundred K to 10(exp 4) K. We report results from 1.3 and 3mm radio interferometric observations of this region with CARMA, and present a spectral index map of this region. We find a range of emission mechanisms in the region, including the inverted synchrotron spectrum of Sgr A*, free-free emission from the mini-spiral arms, and a possible dust emission contribution indicated by a positive spectral index.

  15. Direct typing of Canine parvovirus (CPV) from infected dog faeces by rapid mini sequencing technique.

    Science.gov (United States)

    V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B

    2016-12-01

    Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.

  16. Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta.

    Science.gov (United States)

    Bortoluzzi, C; Paras, K L; Applegate, T J; Verocai, G G

    2018-04-30

    Monitoring Eimeria shedding has become more important due to the recent restrictions to the use of antibiotics within the poultry industry. Therefore, there is a need for the implementation of more precise and accurate quantitative diagnostic techniques. The objective of this study was to compare the precision and accuracy between the Mini-FLOTAC and the McMaster techniques for quantitative diagnosis of Eimeria maxima oocyst in poultry. Twelve pools of excreta samples of broiler chickens experimentally infected with E. maxima were analyzed for the comparison between Mini-FLOTAC and McMaster technique using, the detection limits (dl) of 23 and 25, respectively. Additionally, six excreta samples were used to compare the precision of different dl (5, 10, 23, and 46) using the Mini-FLOTAC technique. For precision comparisons, five technical replicates of each sample (five replicate slides on one excreta slurry) were read for calculating the mean oocyst per gram of excreta (OPG) count, standard deviation (SD), coefficient of variation (CV), and precision of both aforementioned comparisons. To compare accuracy between the methods (McMaster, and Mini-FLOTAC dl 5 and 23), excreta from uninfected chickens was spiked with 100, 500, 1,000, 5,000, or 10,000 OPG; additional samples remained unspiked (negative control). For each spiking level, three samples were read in triplicate, totaling nine reads per spiking level per technique. Data were transformed using log10 to obtain normality and homogeneity of variances. A significant correlation (R = 0.74; p = 0.006) was observed between the mean OPG of the McMaster dl 25 and the Mini-FLOTAC dl 23. Mean OPG, CV, SD, and precision were not statistically different between the McMaster dl 25 and Mini-FLOTAC dl 23. Despite the absence of statistical difference (p > 0.05), Mini-FLOTAC dl 5 showed a numerically lower SD and CV than Mini-FLOTAC dl 23. The Pearson correlation coefficient revealed significant and positive

  17. Mini-Exame do Estado Mental: características psicométricas em idosos ambulatoriais Mini-Mental State Examination: psychometric characteristics in elderly outpatients

    Directory of Open Access Journals (Sweden)

    Roberto A Lourenço

    2006-08-01

    Full Text Available OBJETIVO: Avaliar as características de medida do Mini-Exame do Estado Mental em idosos atendidos em um ambulatório geral. MÉTODOS: O total de 303 indivíduos (>65 anos foi submetido à avaliação geriátrica com vários instrumentos, inclusive o Mini-Exame do Estado Mental. Foram calculadas a sensibilidade, a especificidade, os valores preditivos positivo e negativo e a curva ROC. RESULTADOS: A sensibilidade, a especificidade, os valores preditivos positivo e negativo e a área sob a curva ROC foram 80,8%, 65,3%, 44,7%, 90,7% e 0,807, respectivamente (ponto de corte 23/24. O melhor ponto de corte para indivíduos analfabetos foi 18/19 (sensibilidade =73,5%; especificidade =73,9%, e para aqueles com instrução escolar foi 24/25 (sensibilidade =75%; especificidade =69,7%. CONCLUSÕES: Para o rastreamento cognitivo de idosos atendidos em ambulatórios gerais pelo Mini-Exame do Estado Mental, a escolaridade deverá ser considerada para a adoção do ponto de corte mais adequado.OBJECTIVE: To assess the psychometric characteristics of the Mini-Mental State Examination in elderly outpatients who seek primary health care. METHODS: A total of 303 subjects (>65 years underwent comprehensive geriatric assessment with functional tools, including Mini-Mental State Examination. Sensitivity, specificity, positive predictive value, negative predictive value, and ROC curve were calculated. RESULTS: Sensitivity, specificity, positive and negative predictive values, and area under ROC curve were 80.8%, 65.3%, 44.7%, 90.7% and 0.807 respectively (cutoff point =23/24. The best cutoff point for illiterate was 18/19 (sensitivity =73.5%; specificity =73.9%; and for literate was 24/25 (sensitivity =75%; specificity =69.7%. CONCLUSIONS: While screening elderly outpatients for dementia, schooling must be considered in the choice of the best cutoff point in the Mini-Mental State Examination.

  18. Measuring mental health in the clinical setting: what is important to service users? The Mini-Service user Recovery Evaluation scale (Mini-SeRvE).

    Science.gov (United States)

    Barber, Joanna M; Parsons, Helen; Wilson, Carol A; Cook, Christopher C H

    2017-12-01

    Since 2001, a policy of positive mental health recovery has been promoted in the UK, with service user involvement. This has not been easy to implement in the clinical setting. To develop and validate a brief self-report, service user-designed, outcome measure (Mini-SeRvE), for clinical use, including spiritual and religious issues. From the previously developed Service user Recovery Evaluation scale (SeRvE), 15 questions were selected for Mini-SeRvE which was self-completed by 207 people; 100 service users and, for comparison, 107 staff. Results were analysed using SPSS software (SPSS Inc., Chicago, IL). Mini-SeRvE is reliable, Cronbach's alpha 0.852. Correlation with another recovery scale, Mental Health Recovery Measure, was high, r = 0.819. Three reliable subscales emerged; existential well-being (EWB), mental ill-being (MIB) and religious well-being (RWB). Scores of the EWB and MIB subscales were higher for staff, consistent with higher mental well-being. Religious well-being scores were higher in service users, who also rated religion as more important to them. Mini-SeRvE is a valid measure of service user recovery. The importance of religion/spiritual belief for our users is highlighted, this being reflected in the subject matter of Mini-SeRvE. Mini-SeRvE assessments could show individual priorities, evaluate therapy and aid clinical decision-making.

  19. Analysis of false positive and false negative cytological diagnosis of breast lesions

    International Nuclear Information System (INIS)

    Jamal, Awtif A.; Mansoor, I.

    2001-01-01

    To study the reasons for interpretive errors in false negative and false positive diagnosis of breast carcinoma on fine needle aspiration cytology material. We reviewed only those cases in which cytohistological discrepancies were found, where the cytologic material was abnormal and to some extent misinterpreted or both. There was only one false negative case (false negative fraction 0.32%) proved histologically as ductal carcinoma and four false positive cases (false positive fraction 1.2%); 2 fibroadenoma; 1 fibrocystic disease; and 1 stromal fibrosis. Smears of the two false positive fibroadenoma cases showed very high cellularity, overcrowded clusters and frequent stripped nuclei. The fibrocystic case showed tight clusters of apocrine cells and sheets of loosely aggregated macrophages that were over interpreted. Smears of the false negative ductal carcinoma was hypocellular overall, and the cells showed minimal nuclear pleomorphism. Overcrowded clusters and hypercellular smears should be carefully assessed for uniformity of cells and detailed nuclear and cytomorphological features. If the full-blown malignant cytomorphological changes are not visible, a diagnosis of suspicious or inconclusive should be made and frozen section recommended before surgery. Hypocellularity and relatively nuclear monomorphism are the reasons for failure to diagnose malignant breast lesions. Careful attention should be paid to extreme nuclear monomorphism and absence of naked bipolar cells. A cytologically atypical or suspicious diagnosis together with positive radiological and clinical findings should suggest a diagnosis of malignancy. (author)

  20. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI).

    Science.gov (United States)

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-05-22

    There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen's kappa and "observed agreement". There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and "observed agreement" was above 88%. The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language.

  1. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    Science.gov (United States)

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen’s kappa and “observed agreement”. Results There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and “observed agreement” was above 88%. Conclusion The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language. PMID:24886297

  2. Return of the mini

    International Nuclear Information System (INIS)

    Ashmore, C.

    2001-01-01

    Partly as a result of the contentious nature of some large hydroelectric schemes, and continuing deregulation on a global scale, the mini hydro systems are enjoying unprecedented growth. This article discusses the reasons for the increase in demand for mini hydro systems, and describes Alstom Power Hydro's new, integrated 'water-to-wire' renewable energy solution which is a modular system which integrates the hydro-turbine, generator and controls to provide a single optimised product called the Mini-Aqua. The Mini-Aqua can be supplied inside a turnkey package including all civil works. The company is also looking to the future with development of its Powerformer technology for smaller-scale, grid-connected applications

  3. Consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo J. Fonseca D'El Rey

    2007-01-01

    Full Text Available CONTEXTO: A fobia social é um grave transtorno de ansiedade que traz incapacitação e sofrimento. OBJETIVOS: Investigar a consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN. MÉTODOS: Foi realizado um estudo da consistência interna do Mini-SPIN em uma amostra de 206 estudantes universitários da cidade de São Paulo, SP. RESULTADOS: A consistência interna do instrumento, analisada pelo coeficiente alfa de Cronbach, foi de 0,81. CONCLUSÕES: Esses achados permitiram concluir que a versão em português do Mini-SPIN exibiu resultados de boa consistência interna, semelhantes aos da versão original em inglês.BACKGROUND: Social phobia is a severe anxiety disorder that brings disability and distress. OBJECTIVES: To investigate the internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN. METHODS: We conducted a study of internal consistency of the Mini-SPIN in a sample of 206 college students of the city of São Paulo, SP. RESULTS: The internal consistency of the instrument, analyzed by Cronbach's alpha coefficient, was 0.81. CONCLUSIONS: These findings suggest that the Portuguese version of the Mini-SPIN has a good internal consistency, similar to those obtained with the original English version.

  4. Graphic software ''MiniG'' for the Mini-6

    International Nuclear Information System (INIS)

    Zen, J.

    1984-06-01

    MiniG is a set of subprograms, written and aimed at being used in Fortran for graphic applications in nuclear physics (histograms or point clouds). It includes three representation modes of axis scales (linear, semi-log and squared root), five types of vectors and numerous graphic symbols for spectra representation with or without notation (circle, cross, arrow, triangle, spiral, etc.). It offers also the possibilities of the software ''Plot-10'' of Tektronix, and accept all the types of graphic terminals of SATD connected to Mini-6 [fr

  5. 10-minute delayed recall from the modified mini-mental state test predicts Alzheimer's disease pathology.

    Science.gov (United States)

    Lyness, Scott A; Lee, Ae Young; Zarow, Chris; Teng, Evelyn L; Chui, Helena C

    2014-01-01

    We compared the sensitivity and specificity of two delayed recall scores from the Modified Mini-Mental State (3MS) test with consensus clinical diagnosis to differentiate cognitive impairment due to Alzheimer's disease (AD) versus non-AD pathologies. At a memory disorders clinic, 117 cognitively impaired patients were administered a baseline 3MS test and received a contemporaneous consensus clinical diagnosis. Their brains were examined after death about 5 years later. Using logistic regression with forward selection to predict pathologically defined AD versus non-AD, 10-min delayed recall entered first (p = 0.001), followed by clinical diagnosis (p = 0.02); 1-min delayed recall did not enter. 10-min delayed recall scores ≤4 (score range = 0-9) were 87% sensitive and 47% specific in predicting AD pathology; consensus clinical diagnosis was 82% sensitive and 45% specific. For the 57 patients whose initial Mini-Mental State Examination scores were ≥19 (the median), 3MS 10-min delayed recall scores ≤4 showed some loss of sensitivity (80%) but a substantial gain in specificity (77%). In conclusion, 10-min delayed recall score on the brief 3MS test distinguished between AD versus non-AD pathology about 5 years before death at least as well as consensus clinical diagnosis that requires much more comprehensive information and complex deliberation.

  6. P A Mini

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. P A Mini. Articles written in Bulletin of Materials Science. Volume 36 Issue 4 August 2013 pp 547-551. Composite supercapacitor electrodes made of activated carbon/PEDOT:PSS and activated carbon/doped PEDOT · T S Sonia P A Mini R Nandhini Kalluri Sujith Balakrishnan ...

  7. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN) Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)

    OpenAIRE

    Gustavo José Fonseca D'El Rey; Cláudia Wilmor Matos

    2009-01-01

    A fobia social (também conhecida como transtorno de ansiedade social) é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN) em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426) de um estudo de prevalência de transtornos de ansieda...

  8. Non-invasive prenatal diagnosis of monogenic disorders: an optimized protocol using MEMO qPCR with miniSTR as internal control.

    Science.gov (United States)

    Guissart, Claire; Debant, Vanessa; Desgeorges, Marie; Bareil, Corinne; Raynal, Caroline; Toga, Caroline; Pritchard, Victoria; Koenig, Michel; Claustres, Mireille; Vincent, Marie-Claire

    2015-02-01

    Analysis of circulating cell-free fetal DNA (cffDNA) in maternal plasma is very promising for early diagnosis of monogenic diseases. However, this approach is not yet available for routine use and remains technically challenging because of the low concentration of cffDNA, which is swamped by the overwhelming maternal DNA. To make clinical applications more readily accessible, we propose a new approach based on mutant enrichment with 3'-modified oligonucleotides (MEMO) PCR along with real-time PCR to selectively amplify from the maternal blood the paternally inherited fetal allele that is not present in the maternal genome. The first proof of concept of this strategy was displayed for cystic fibrosis by the accuracy of our detection of the p.Gly542* mutation used as the initial developmental model. Subsequently, a retrospective study of plasmas originating from two pregnant women carrying a fetus with private mutation confirmed the effectiveness of our method. We confirmed the presence of cffDNA in the studied samples by the identification of a tri-allelic DNA profile using a miniSTR kit. This new non-invasive prenatal diagnosis test offers numerous advantages over current methods: it is simple, cost effective, time efficient and does not require complex equipment or bioinformatics settings. Moreover, our assays for different private mutations demonstrate the viability of this approach in clinical settings for monogenic disorders.

  9. Premature pubarche before one year of age: distinguishing between mini-puberty variants and precocious puberty.

    Science.gov (United States)

    Bourayou, Rafik; Giabicani, Eloïse; Pouillot, Monique; Brailly-Tabard, Sylvie; Brauner, Raja

    2015-04-02

    The aim of this study was to facilitate the distinction between the benign "mini-puberty of early infancy" and precocious puberty (PP). We compared 59 patients (21 boys and 38 girls) seen for pubic hair development before one year of age diagnosed as mini-puberty to 13 patients (2 boys) in whom pubertal development before one year revealed a PP. The boys with mini-puberty presented with pubic hair development and prepubertal testicular volume, with low plasma testosterone concentrations. Their gonadotropin responses to gonadotropin releasing hormone (GnRH) test showed predominant luteinising hormone increase in 9/13. The girls presented with pubic hair development that was accompanied by breast development in 47% of cases, with low plasma estradiol concentrations. Their gonadotropin responses showed predominant follicle-stimulating hormone increase in the 17 evaluated. The patients with PP had organic central PP (5 hypothalamic hamartoma) or idiopathic central PP (n=6), or peripheral PP (one ovarian tumor and one congenital adrenal hyperplasia). The diagnosis was challenging only in 3 girls with idiopathic central PP presenting with prepubertal plasma estradiol concentrations and responses to GnRH test. The diagnosis of PP was easily determined based on the clinical presentation and the pubertal concentrations of testosterone in boys or of estradiol in girls, as was the diagnosis of central or peripheral origin of PP based on gonadotropin response to the GnRH test. Once PP is excluded, these patients need careful follow-up and physician consultation is needed if clinical pubertal signs progress.

  10. Examining the reliability and validity of the Hebrew version of the Mini Mental State Examination.

    Science.gov (United States)

    Werner, P; Heinik, J; Mendel, A; Reicher, B; Bleich, A

    1999-10-01

    The Mini Mental State Examination is used worldwide for the screening and diagnosis of dementia. The aim of the present study was to examine the reliability and validity of the Hebrew version of the Mini Mental State Examination. The Hebrew version of the Mini Mental State Examination was administered to 36 demented and 19 non-demented elderly persons. Test-retest reliability scores were calculated as exact agreement rates, and ranged from good to excellent for all the items. Strong convergent validity, as measured by the correlation between the MMSE and the CAM-COG (r = 0.94), was found. Good predictive value was observed as over three-quarters of the participants were correctly classified as demented or non-demented. The Hebrew version of the MMSE was found to be a useful and valid instrument for the determination of dementia in the elderly population.

  11. MiniCNT - A Tabletop Stellarator

    Science.gov (United States)

    Dugan, Chris; Pedersen, Thomas; Berkery, John

    2006-10-01

    MiniCNT is a scaled down version of the Columbia Non-Neutral Torus, a stellarator built to study confinement of non-neutral plasmas on magnetic surfaces. MiniCNT is a glass vacuum chamber capable of holding pressures six orders of magnitude below atmospheric pressure. Unlike CNT, in which plasmas are invisible, MiniCNT allows some collisions with neutrals, causing it to glow. Using two twelve-volt car batteries to power four magnetic coils, MiniCNT generates a 0.02 Tesla magnetic field. While CNT, being larger, is obviously more accurate, there are multiple benefits in MiniCNT. First, it is more flexible and can be adjusted to fit many scenarios easily. The car batteries can be switched for other power sources, the coils can be realigned, and the chamber can be pumped to various pressures of various gases. Also, it is visually accessible; while CNT has glass viewing ports and its plasma is dark, MiniCNT is made of glass and its plasma glows, allowing visualization of the magnetic surfaces.

  12. Mini-Cog and Mini-Mental State Examination: agreement in a cross-sectional study with an elderly sample.

    Science.gov (United States)

    Costa, Diogo; Severo, Milton; Fraga, Sílvia; Barros, Henrique

    2012-01-01

    We aimed to compare the Mini-Mental State Examination (MMSE) with the Mini-Cog, measuring agreement in participants' classification, using a general population sample. Cross-sectional evaluation of 609 community dwellers aged ≥60 years was performed by trained interviewers. Cohen's kappa and 95% confidence intervals (CI) were calculated to assess overall agreement, and Cronbach alphas computed to assess reliability. Two-parameter Item Response Theory models (difficulty and discrimination parameters) were used to assess discrimination. Considering MMSE cut-point for scores Mini-Cog's cut-point score Mini-Cog Mini-Cog Mini-Cog's alpha was 0.2776. Co-calibration according to inherent ability is graphically presented. Agreement between scales seems fragile in our sample. The discriminative and reliability analysis suggests a better performance for subsets of the MMSE compared with the Mini-Cog. Usefulness of calibrated scores is discussed. Copyright © 2012 S. Karger AG, Basel.

  13. MiniDraw

    DEFF Research Database (Denmark)

    2018-01-01

    MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010.......MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010....

  14. Mini-grid Policy Tool-kit. Policy and business frameworks for successful mini-grid roll-outs

    International Nuclear Information System (INIS)

    Franz, Michael; Hayek, Niklas; Peterschmidt, Nico; Rohrer, Michael; Kondev, Bozhil; Adib, Rana; Cader, Catherina; Carter, Andrew; George, Peter; Gichungi, Henry; Hankins, Mark; Kappiah, Mahama; Mangwengwende, Simbarashe E.

    2014-01-01

    The Mini-grid Policy Tool-kit is for policy makers to navigate the mini-grid policy design process. It contains information on mini-grid operator models, the economics of mini-grids, and necessary policy and regulation that must be considered for successful implementation. The publication specifically focuses on Africa. Progress on extending the electricity grid in many countries has remained slow because of high costs of gird-extension and limited utility/state budgets for electrification. Mini-grids provide an affordable and cost-effective option to extend needed electricity services. Putting in place the right policy for min-grid deployment requires considerable effort but can yield significant improvement in electricity access rates as examples from Kenya, Senegal and Tanzania illustrate. The tool-kit is available in English, French and Portuguese

  15. Association of the position of a hospital-acquired condition diagnosis code with changes in medicare severity diagnosis-related group assignment.

    Science.gov (United States)

    Johnson, Tricia; Kane, Jason M; Odwazny, Richard; McNutt, Robert

    2014-11-01

    Incentives to improve quality include paying less for adverse events, including the Centers for Medicare and Medicaid Services' policy to not pay additionally for events classified as hospital-acquired conditions (HACs). This policy is controversial, as variable coding practices at hospitals may lead to differences in the inclusion and position of HACs in the list of codes used for Medicare Severity Diagnosis-Related Group (MS-DRG) assignment. Evaluate changes in MS-DRG assignment for patients with an HAC and test the association of the position of an HAC in the list of International Classification of Diseases, 9th Revision (ICD-9) diagnosis codes with change in MS-DRG assignment. Retrospective analysis of patients discharged from hospital members of the University HealthSystem Consortium's Clinical Data Base between October 2007 and April 2008. Comparisons were made between the MS-DRG assigned when the HAC was not included in the list of ICD-9 diagnosis codes and the MS-DRG that would have been assigned had the HAC code been included in the assignment. Of the 7027 patients with an HAC, 13.8% changed MS-DRG assignment when the HAC was removed. An HAC in the second position versus third position or lower was associated with a 40-fold increase in the likelihood of MS-DRG change. The position of an HAC in the list of diagnosis codes, rather than the presence of an HAC, is associated with a change in MS-DRG assignment. HACs have little effect on reimbursement unless the HAC is in the second position and patients have minor severity of illness. © 2014 Society of Hospital Medicine.

  16. Review of mini-clinical evaluation exercise (mini-CEX in a psychiatry clerkship

    Directory of Open Access Journals (Sweden)

    Meresh E

    2018-04-01

    Full Text Available Edwin Meresh,1 David Daniels,2 Aparna Sharma,1 Murali Rao,1 Kaushal Mehta,3 David Schilling1 1Department of Psychiatry and Behavioral Neurosciences, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA; 2Department of Psychiatry, Medstar Georgetown University Hospital, Washington, DC, USA; 3School of Public Health, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL USA Background: Direct observation of medical students with actual patients is important for the assessment of clinical skills including interviewing and counseling skills. This article describes medical students’ experience of mini-clinical evaluation exercise (mini-CEX during their clerkship in consultation psychiatry. Materials and methods: In our center during inpatient consultation psychiatry clerkship, all rotating students are expected to complete one mini-CEX assessment as part of their clinical training. We conducted retrospective analysis of mini-CEX ratings completed from 2013 to 2016. All evaluations took place at inpatient medical setting in patients admitted with medical conditions and psychiatric comorbidities. Results: A total of 113 evaluations were reviewed. The time examiner observed the interaction of a student with the patient was 14.24 minutes (mean, and the time spent in providing feedback to the student was 9.71 minutes. Complexity of problem was rated as low in 0.88% (n=1, moderate in 50.44% (n=57, and high in 48.67% (n=55. Highest ratings were for professionalism, similar to previous reports. Total score calculated by examiner showed no difference by the complexity of the patient; however, we observed a trend in higher counseling score for the high complexity group. Conclusion: Mini-CEX assessment during busy clerkship is feasible with good outcomes. Direct observation of medical trainees with actual patients is important for the assessment of performance-based clinical skills. Hospital psychiatry rotation

  17. MiniGRAIL progress report 2004

    International Nuclear Information System (INIS)

    Waard, A de; Benzaim, Y; Frossati, G; Gottardi, L; Mark, H van der; Flokstra, J; Podt, M; Bassan, M; Minenkov, Y; Moleti, A; Rocchi, A; Fafone, V; Pallottino, G V

    2005-01-01

    The MiniGRAIL detector was improved. The sphere was replaced by a slightly larger one, having a diameter of 68 cm (instead of 65 cm), reducing the resonant frequency by about 200 Hz to around 2.9 kHz. The last four masses of the attenuation system were machined to increase their resonant frequency and improve the attenuation around the resonant frequency of the sphere. In the new sphere, six holes were machined on the TIGA positions for easy mounting of the transducers. During the last cryogenic run, two capacitive transducers and a calibrator were mounted on the sphere. The first transducer was coupled to a double-stage SQUID amplifier having a commercial quantum design SQUID as a first stage and a DROS as a second stage. The second transducer was read by a single-stage quantum design SQUID. During the cryogenic run, the sphere was cooled down to 4 K. The two-stage SQUID had a flux noise of about 1.6 μφ 0 Hz -1/2 . The detector was calibrated and the sensitivity curve of MiniGRAIL was determined

  18. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    OpenAIRE

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnos...

  19. iPad mini for dummies

    CERN Document Server

    Baig, Edward C

    2014-01-01

    Find out why the iPad mini has never been bigger This new edition of iPad mini For Dummies covers all the latest tips and tricks for getting an even bigger bang out of your iPad mini. Presented in full-color and written in the straightforward but fun language that has defined the For Dummies brand for more than twenty years, this friendly guide walks you through the multitouch interface, going online, getting connected, packing your iPad mini with apps, games, e-books, photos, music, and movies, synchronizing your data, texting with iMessage, working with Siri, importing pictures and launching

  20. DIAGNOSIS AND MANAGEMENT BENIGN PAROXYSMAL POSITIONAL VERTIGO (BPPV

    Directory of Open Access Journals (Sweden)

    Putu Prida Purnamasari

    2013-05-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 Benign Paroxysmal Positional Vertigo (BPPV is one of the most frequent Neurotology disorders. Benign Paroxysmal Positional Vertigo is a vestibular disorder in which 17% -20% of patients complained of vertigo. In the general population the prevalence of BPPV is between 11 to 64 per 100,000 (prevalence 2.4%. Benign Paroxysmal Positional Vertigo is a disturbance in the inner ear with positional vertigo symptoms that occur repeatedly with the typical nystagmus paroxysmal. The disorders can be caused either by canalithiasis or cupulolithiasis and could in theory be about three semicircular canals, although superior canal (anterior is very rare. The most common is the form of the posterior canal, followed by a lateral. The diagnosis of BPPV can be enforced based on history and physical examination, including some tests such as Dix-Hallpike test, caloric test, and Supine Roll test. The diagnosis of BPPV is also classified according to the types of channels. Management of BPPV include non-pharmacological, pharmacological and operations. Treatment is often used non-pharmacological includes several maneuvers such as Epley maneuver, Semount maneuver, Lempert maneuver, forced prolonged position and Brandt-Daroff exercises. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  1. Mini-implantes ortodônticos como auxiliares da fase de retração anterior Orthodontic mini-implants assisting the anterior retraction phase

    Directory of Open Access Journals (Sweden)

    Carlo Marassi

    2008-10-01

    Full Text Available INTRODUÇÃO: os mini-implantes ortodônticos se estabeleceram como um importante método de ancoragem e vêm auxiliando os ortodontistas nas várias etapas do tratamento ortodôntico, eliminando, em grande parte, a necessidade de colaboração dos pacientes e tornando os resultados mais previsíveis. OBJETIVO: este artigo descreve os principais aspectos do uso dos mini-implantes como auxiliares da fase de retração anterior, trazendo considerações sobre suas indicações, quantidade de movimentação dos dentes anteriores, os vetores de força de retração, o controle vertical, o posicionamento dos mini-implantes, os tipos de apoio na região anterior e a força a ser utilizada. São citados os sítios de instalação mais usados para a retração anterior e abordados fatores que deverão ser controlados durante o fechamento de espaço. Por fim, são citadas algumas considerações clínicas sobre o uso dos mini-implantes nessa importante fase do tratamento ortodôntico.INTRODUCTION: The use of orthodontic mini-implants has settled as an important anchorage method and is aiding the orthodontists in the several stages of the treatment, largely eliminating the need of patients' compliance, and turning the results more predictable. AIM: This article describes the main aspects of the use of mini-implants as auxiliaries on the retraction phase of the anterior teeth, bringing considerations about their indications, amount of movement of the anterior teeth, the vectors of retraction force, the vertical control and evaluation of the incisors vestibulolingual tipping, the positioning of the mini-implants, the support types in the anterior area and the force to be applied. The placement sites best used for the anterior retraction are mentioned, and the factors that should be controlled during the space closure are approached. Lastly, some clinical considerations on the use of mini-implants in such important phase of the orthodontic treatment are

  2. Prenatal radiographic diagnosis of alpha-fetoprotein positive malformations in early pregnancy

    International Nuclear Information System (INIS)

    Probst, F.P.; Sigurd, J.

    1980-01-01

    Early diagnosis of two malformed fetuses with positive alpha-fetoprotein test of the amniotic fluid with the aid of amniography is reported. Radiographic, diagnostic and prognostic aspects are discussed. (Auth.)

  3. Spurious RF signals emitted by mini-UAVs

    NARCIS (Netherlands)

    Schleijpen, R.; Voogt, V.; Zwamborn, P.; Oever, J. van den

    2016-01-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to

  4. The Mini-Social Phobia Inventory: psychometric properties in an adolescent general population sample.

    Science.gov (United States)

    Ranta, Klaus; Kaltiala-Heino, Riittakerttu; Rantanen, Päivi; Marttunen, Mauri

    2012-07-01

    Onset of social phobia (SP) typically occurs in adolescence. Short screening instruments for its assessment are needed for use in primary health and school settings. The 3-item Mini-Social Phobia Inventory (SPIN) has demonstrated effectiveness in screening for generalized SP (GSP) in adults. This study examined the psychometrics of the Mini-SPIN in an adolescent general population sample. Three hundred fifty adolescents aged 12 to 17 years were clinically interviewed using the Schedule for Affective Disorders and Schizophrenia for School-Age Children-Present and Lifetime Version for identification of SP and other Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Axis I disorders, blind to their Mini-SPIN status. Associations between SP; subclinical SP; other anxiety, depressive, and disruptive disorders; and Mini-SPIN scores were examined, and diagnostic efficiency statistics were calculated. The association between Mini-SPIN scores and the generalized subtype of SP was also examined. As in adults, the Mini-SPIN items differentiated subjects with SP from those without. A score of 6 points or greater was found optimal in predicting SP with a sensitivity of 86%, specificity of 84%, and positive and negative predictive values of 26% and 99%. The Mini-SPIN also possessed discriminative validity, as scores were higher for adolescents with SP than they were for those with depressive, disruptive, and other anxiety disorders. The Mini-SPIN was also able to differentiate adolescents with GSP from the rest of the sample. The Mini-SPIN has good psychometrics for screening SP in adolescents from general population and may have value in screening for GSP. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Imaging diagnosis--positive contrast peritoneographic features of true diaphragmatic hernia.

    Science.gov (United States)

    Choi, Jihye; Kim, Hyunwook; Kim, Mieun; Yoon, Junghee

    2009-01-01

    A true diaphragmatic hernia is a congenital diaphragmatic malformation that can appear identical to a peritoneopericardial diaphragmatic hernia (PPDH). True diaphragmatic hernias are rare in dogs. Herein we describe the use of positive contrast peritoneography for diagnosis of a true diaphragmatic hernia in two dogs.

  6. Psychometric Evaluation of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID).

    Science.gov (United States)

    Duncan, Laura; Georgiades, Kathy; Wang, Li; Van Lieshout, Ryan J; MacMillan, Harriet L; Ferro, Mark A; Lipman, Ellen L; Szatmari, Peter; Bennett, Kathryn; Kata, Anna; Janus, Magdalena; Boyle, Michael H

    2017-12-04

    The goals of the study were to examine test-retest reliability, informant agreement and convergent and discriminant validity of nine DSM-IV-TR psychiatric disorders classified by parent and youth versions of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID). Using samples drawn from the general population and child mental health outpatient clinics, 283 youth aged 9 to 18 years and their parents separately completed the MINI-KID with trained lay interviewers on two occasions 7 to 14 days apart. Test-retest reliability estimates based on kappa (κ) went from 0.33 to 0.79 across disorders, samples and informants. Parent-youth agreement on disorders was low (average κ = 0.20). Confirmatory factor analysis provided evidence supporting convergent and discriminant validity. The MINI-KID disorder classifications yielded estimates of test-retest reliability and validity comparable to other standardized diagnostic interviews in both general population and clinic samples. These findings, in addition to the brevity and low administration cost, make the MINI-KID a good candidate for use in epidemiological research and clinical practice. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. [Bone remodeling and modeling/mini-modeling.

    Science.gov (United States)

    Hasegawa, Tomoka; Amizuka, Norio

    Modeling, adapting structures to loading by changing bone size and shapes, often takes place in bone of the fetal and developmental stages, while bone remodeling-replacement of old bone into new bone-is predominant in the adult stage. Modeling can be divided into macro-modeling(macroscopic modeling)and mini-modeling(microscopic modeling). In the cellular process of mini-modeling, unlike bone remodeling, bone lining cells, i.e., resting flattened osteoblasts covering bone surfaces will become active form of osteoblasts, and then, deposit new bone onto the old bone without mediating osteoclastic bone resorption. Among the drugs for osteoporotic treatment, eldecalcitol(a vitamin D3 analog)and teriparatide(human PTH[1-34])could show mini-modeling based bone formation. Histologically, mature, active form of osteoblasts are localized on the new bone induced by mini-modeling, however, only a few cell layer of preosteoblasts are formed over the newly-formed bone, and accordingly, few osteoclasts are present in the region of mini-modeling. In this review, histological characteristics of bone remodeling and modeling including mini-modeling will be introduced.

  8. The MiniBooNE Detector

    OpenAIRE

    MiniBooNE Collaboration

    2008-01-01

    The MiniBooNE neutrino detector was designed and built to look for muon-neutrino to electron-neutrino oscillations in the mixing parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  9. A DNA mini-barcode for land plants.

    Science.gov (United States)

    Little, Damon P

    2014-05-01

    Small portions of the barcode region - mini-barcodes - may be used in place of full-length barcodes to overcome DNA degradation for samples with poor DNA preservation. 591,491,286 rbcL mini-barcode primer combinations were electronically evaluated for PCR universality, and two novel highly universal sets of priming sites were identified. Novel and published rbcL mini-barcode primers were evaluated for PCR amplification [determined with a validated electronic simulation (n = 2765) and empirically (n = 188)], Sanger sequence quality [determined empirically (n = 188)], and taxonomic discrimination [determined empirically (n = 30,472)]. PCR amplification for all mini-barcodes, as estimated by validated electronic simulation, was successful for 90.2-99.8% of species. Overall Sanger sequence quality for mini-barcodes was very low - the best mini-barcode tested produced sequences of adequate quality (B20 ≥ 0.5) for 74.5% of samples. The majority of mini-barcodes provide correct identifications of families in excess of 70.1% of the time. Discriminatory power noticeably decreased at lower taxonomic levels. At the species level, the discriminatory power of the best mini-barcode was less than 38.2%. For samples believed to contain DNA from only one species, an investigator should attempt to sequence, in decreasing order of utility and probability of success, mini-barcodes F (rbcL1/rbcLB), D (F52/R193) and K (F517/R604). For samples believed to contain DNA from more than one species, an investigator should amplify and sequence mini-barcode D (F52/R193). © 2013 John Wiley & Sons Ltd.

  10. The 'mini brain' appearance of plasmacytoma in the appendicular skeleton

    Energy Technology Data Exchange (ETDEWEB)

    Subhas, N.; Sundaram, M. [Cleveland Clinic, Department of Diagnostic Radiology, Cleveland, OH (United States); Bauer, T.W. [Cleveland Clinic, Department of Anatomic Pathology, Cleveland, OH (United States); Joyce, M.J. [Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH (United States)

    2008-08-15

    We report on the case of a 70-year-old woman presenting with right hip pain. Radiographs of the right hip demonstrated a well-defined large lytic lesion in the proximal right femur, with prominent trabeculae situated peripherally and extending into the lesion in a 'spoke-wheel' pattern. Magnetic resonance imaging (MRI) demonstrated solid enhancing marrow-replacing lesion, with intervening linear nonenhancing areas of low T2 signal intensity. The MRI appearance resembled that of a small brain or 'mini brain'. Biopsy specimen demonstrated predominantly mature plasma cells, with occasional admixed immature forms. A diagnosis of plasmacytosis, consistent with myeloma, was made. This case illustrates a rare but seemingly characteristic 'mini brain' appearance of plasmacytoma, which, to date, has only been reported in the spine and has not been observed in other bony lesions. (orig.)

  11. The Norwegian version of the Mini-Mental Adjustment to Cancer Scale: factor structure and psychometric properties.

    Science.gov (United States)

    Bredal, Inger Schou

    2010-02-01

    The object of the study was to examine the factor structure and the psychometric properties of the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) among a large sample of Norwegian breast cancer patients. A total of 402 patients with breast cancer completed the Mini-MAC. Principal component analysis with varimax rotion confirmed four factors. Three had psychometric properties to the original Mini-MAC Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) subscales. The fourth, named Positive Attitude (PA) combined the Fighting Spirit (FS) and the Fatalism subscales of the original Mini-MAC. Construct validities were assessed by examining the interscale correlations as well as the correlations between the Mini-MAC subscales and the HADS subscales scores. Internal consistency of the five subscales was satisfactory for the original (HH, AP, CA, FA, coefficients=0.60-0.83), except for the FS subscale (coefficient=21). In view of the low internal reliability for the Norwegian Mini-MAC FS subscale coefficient; it appears to be more appropriate to use the Norwegian Mini-MAC as a four-factor model. If researcher or clinicians in Norway use the five-factor model, they should take great care when interpreting the fighting spirit subscale.

  12. RESPON LINGKUNGAN BELANJA SEBAGAI STIMULUS PEMBELIAN TIDAK BERENCANA PADA MINI MARKET MAMI MART PAINAN

    Directory of Open Access Journals (Sweden)

    Mareta Kemala Sari

    2014-10-01

    Full Text Available Research planning not purchase the mami mini market mart visits from customer response to environmental spending as a stimulus, a customer case study on mini market mart mom Painan. Research using response variables shopping environment consisting of Pleasure, Arousal, Dominance.as mediator variable, hedonic shopping value, utilitarian shopping value, resources expenditure on the purchase was not planned (Impulse Buying. Data were collected using questionnaires distributed during the 2 weeks to the respondents who never shop at mini market. The study population is that they all are a mini market mami mart customers aged 18-55 years and have never shopped with a minimum of 2 times the transaction, the methods used by the descriptive analysis, and processing research model with smartPLS program. Mengunggapkan research results that the response variable dominance shopping environment positive effect on resources expenditure. Shopping environment arousal response variable positive effect on resources expenditure. Also revealed that spending resources poengalaman variable expenditure not a mediator between the response variable shopping environment and other variables shopping experience, as well as the negative effect on the purchase was not planned. But the expenditure of resources affect the shopping experience more variables such as the hedonic shopping value, utilitarian shopping value, resources expenditure

  13. High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection

    International Nuclear Information System (INIS)

    Scopinaro, F.; Capriotti, G.; Di Santo, G.; Capotondi, C.; Micarelli, A.; Massari, R.; Trotta, C.; Soluri, A.

    2006-01-01

    The diagnosis of diabetic foot osteomyelitis is often difficult. 99m Tc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7x25.7 mm 2 FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. 99m Tc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot

  14. High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Capriotti, G. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Di Santo, G. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Capotondi, C. [Unit of Radiology, S. Andrea Hospital, Rome (Italy); Micarelli, A. [Nuclear Medicine, Sulmona Hospital, Sulmona (AQ) (Italy); Massari, R. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy); Trotta, C. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy); Soluri, A. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy)]. E-mail: soluri@isib.cnr.it

    2006-12-20

    The diagnosis of diabetic foot osteomyelitis is often difficult. {sup 99m}Tc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7x25.7 mm{sup 2} FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. {sup 99m}Tc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot.

  15. Beyond Screening: Can the Mini-Mental State Examination be Used as an Exclusion Tool in a Memory Clinic?

    Science.gov (United States)

    Xu, Xin; Chong, Eddie; Hilal, Saima; Ikram, Mohammad Kamran; Venketasubramanian, Narayanaswamy; Chen, Christopher

    2015-11-04

    This study explores whether the Mini-Mental State Examination (MMSE) could reliably exclude definite dementia and dementia-free cases from requiring more extensive neuropsychological investigations in memory clinic settings in Singapore. Patients with memory complaints referred for possible dementia underwent the MMSE, followed by standardized neuropsychological and clinical assessments which led to a consensus diagnosis. MMSE cut-off points were derived stratified for education (less and equal/above primary level). Results show that after education stratification, using an optimal Positive Likelihood Ratio (PLR) and optimal Negative Likelihood Ratio (NLR), a higher percentage of patients were correctly identified as having dementia or dementia-free, with minimal misclassification rate. The finding suggests the MMSE can be used to exclude patients not requiring full neuropsychological assessments in a memory clinic.

  16. The MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, A.A.; Anderson, C.E.; Bartoszek, L.M.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; Curioni, A.; Djurcic, Z.; Finley, D.A.; Fleming, B.T.; Ford, R.; Garcia, F.G.; Garvey, G.T.; Green, C.; Green, J.A.

    2009-01-01

    The MiniBooNE neutrino detector was designed and built to look for ν μ →ν e oscillations in the (sin 2 2θ,Δm 2 ) parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  17. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  18. Design guidelines for mini-roundabouts

    CSIR Research Space (South Africa)

    Emslie, I

    1997-03-01

    Full Text Available Guidelines for Traffic Calming. Concepts and principles relating to the use of mini-roundabouts as a form of intersection control and in the traffic calming context are discussed. Warrants for the implementation of mini-roundabouts and design standards...

  19. MiniBooNE Oscillation Results

    International Nuclear Information System (INIS)

    Djurcic, Zelimir

    2009-01-01

    These proceedings summarize the MiniBooNE ν μ → ν e results, describe the first (bar ν) μ → (bar ν) e result, and current analysis effort with the NuMI neutrinos detected in the miniBooNE detector

  20. Myosin heavy chain isoform expression in adult and juvenile mini-muscle mice bred for high-voluntary wheel running.

    Science.gov (United States)

    Talmadge, Robert J; Acosta, Wendy; Garland, Theodore

    2014-11-01

    The myosin heavy chain (MyHC) isoform composition of locomotor and non-locomotor muscles of mini-muscle mice were assessed at the protein and mRNA levels in both adult and juvenile (21 day old) mice. Mini-muscle mice are one outcome of a replicated artificial selection experiment in which four lines of mice were bred for high voluntary wheel running (HR lines). Two of the lines responded with an increase in frequency of a single nucleotide polymorphism in an intron in the MyHC-2b gene (myh4) that when homozygous causes a dramatic reduction in triceps surae mass. We found that both locomotor and non-locomotor muscles of adult mini-muscle mice displayed robust reductions, but not elimination, of the MyHC-2b isoform at both the protein and mRNA levels, with commensurate increases in MyHC-2x and sometimes MyHC-2a, as compared with either a line of HR mice that does not display the mini-muscle phenotype or inbred C57Bl6 mice. Immunohistochemical analyses revealed that locomotor muscles of mini-muscle mice contain fibers that express the MyHC-2b isoform, which migrates normally in SDS-PAGE gels. However, these MyHC-2b positive fibers are generally smaller than the surrounding fibers and smaller than the MyHC-2b positive fibers of non-mini-muscle mice, resulting in characteristically fast muscles that lack a substantial MyHC-2b positive (superficial) region. In contrast, the masseter, a non-locomotor muscle of mini-muscle mice contained MyHC-2b positive fibers that stained more lightly for MyHC-2b, but appeared normal in size and distribution. In adults, many of the MyHC-2b positive fibers in the mini-muscle mice also display central nuclei. Only a small proportion of small MyHC-2b fibers in mini-muscle mice stained positive for the neural cell adhesion molecule, suggesting that anatomical innervation was not compromised. In addition, weanling (21 day old), but not 5 day old mice, displayed alterations in MyHC isoform content at both the protein and mRNA levels, including

  1. Caisson disease of bone: a study of the Göttingen mini-pig as an animal model.

    Science.gov (United States)

    Gregg, P J; Walder, D N; Rannie, I

    1980-02-01

    Investigation of the exact aetiology, early diagnosis and prevention of caisson disease of bone has been hindered by the inability to produce, by the use of realistic compression/decompression exposures, truly comparable lesions in animals. Four Gottingen mini-pigs were subjected to repeated exposures to pressures of 27 p.s.i.g. for 6 h over a period of 9 months and decompressed according to standard tables. Two mini-pigs acted as controls. In one animal radiological changes were recognised in the left lower femoral shaft 19 weeks after the exposures were started and subsequent examination of that bone confirmed the presence, at that site, of a lesion which macroscopically and microscopically resembled, in every way, the appearances of those seen in the shafts of long bones in man. It is concluded therefore that, properly used, the mini-pig may be a suitable animal model for the study of this condition in man.

  2. Mini-Sniffer on Lakebed

    Science.gov (United States)

    1974-01-01

    The original Mini-Sniffer on Rogers Dry Lake, adjacent to NASA's Flight Research Center, Edwards AFB. This version of the remotely-piloted vehicle had swept-back wings, tip rudders, nose canards, and an air breathing engine. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  3. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  4. Magnet-Sleeve-Sealed Mini Trochoidal-Gear Pump Prototype with Polymer Composite Gear

    Directory of Open Access Journals (Sweden)

    Pedro Javier Gamez-Montero

    2017-09-01

    Full Text Available The trochoidal-gear technology has been growing in groundbreaking fields. Forthcoming applications are demanding to this technology a step forward in the conceiving stage of positive displacement machines. The compendium of the qualities and the inherent characteristics of trochoidal-gear technology, especially towards the gerotor pump, together with scale/size factor and magnetic-driven transmission has led to the idea of a magnet-sleeve-sealed variable flow mini trochoidal-gear pump. From its original concept, to the last phase of the design development, the proof of concept, this new product will intend to overcome problems such as noise, vibration, maintenance, materials, and dimensions. The paper aims to show the technological path followed from the concept, design, and model, to the manufacture of the first prototype, where the theoretical and numerical approaches are not always directly reflected in the prototype performance results. Early in the design process, from a standard-commercial sintered metal mini trochoidal-gear unit, fundamental characteristics and dimensional limitations have been evaluated becoming the strategic parameters that led to its configuration. The main technical challenge to confront is being sealed with non-exterior driveshaft, ensuring that the whole interior is filled and wetted with working fluid and helping the hydrodynamic film formation, the pumping effect, and the heat dissipation. Subsequently, the mini pump architecture, embodiment, methodology, materials, and manufacture are presented. The trend of applications of polymer composite materials and their benefits wanted to be examined with this new mini pump prototype, and a pure polyoxymethylene mini trochoidal-gear set has been designed and manufactured. Finally, both the sintered and the polymer trochoidal-gear units have been experimentally tested in an in-house full-instrumented mini test bench. Although the main goal of the presented work is the

  5. The Individual Features Of Indonesian-Chinese Mini-Novels

    Directory of Open Access Journals (Sweden)

    Ma Feng

    2011-11-01

    Full Text Available This article talks about mini-novels in the new period of Indonesian Chinese Literature. Through the overall developing trend of mini-novels’ corpuses, analyzes the individual creative features: firstly, the humor of Mo Mingmiao’s Mini-novels; secondly, the compassion of Xiao Xing’s Mini-novels; thirdly, Yuan Ni’s emotional sonata of The Lost Key-ring. By combination of themes and techniques of the three mini-novels corpuses, the article focuses on the analysis of three writers’ distinctive writing style.

  6. Mini-Sniffer II in Flight

    Science.gov (United States)

    1976-01-01

    This photograph shows the second Mini-Sniffer undergoing flight testing over Rogers Dry Lake in Edwards, California. This version of the Mini-Sniffer lacked the canard of the original version and had wing tips and tail booms added. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  7. Current Status of the MiniBooNE Experiment

    OpenAIRE

    Ray, H.; collaboration, for the MiniBooNE

    2004-01-01

    MiniBooNE is an experiment designed to refute or confirm the LSND anti-nu_mu -> anti-nu_e oscillation result. MiniBooNE will look for oscillations of nu_mu -> nu_e in a closed-box appearance analysis. MiniBooNE began collecting data in 2002, and is expected to continue data taking through 2005. Current MiniBooNE results are presented.

  8. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, Ian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burman, Kari [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, Mohit [National Renewable Energy Lab. (NREL), Golden, CO (United States); Esterly, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mutiso, Rose [US Department of Energy, Washington, DC (United States); McGregor, Caroline [US Department of Energy, Washington, DC (United States)

    2016-11-01

    Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that

  9. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  10. Distinct trajectories of positive and negative affect after colorectal cancer diagnosis.

    Science.gov (United States)

    Ciere, Yvette; Janse, Moniek; Almansa, Josué; Visser, Annemieke; Sanderman, Robbert; Sprangers, Mirjam A G; Ranchor, Adelita V; Fleer, Joke

    2017-06-01

    Insight into trajectories of positive affect (PA) and negative affect (NA) across the cancer continuum may improve understanding of the nature of adjustment problems. The primary aim of this study was to identify subgroups of patients with distinct trajectories of PA and NA following diagnosis of colorectal cancer (CRC). Secondary to this aim, the co-occurrence between trajectories and their association with goal-related processes was explored. CRC patients (n = 186) completed questionnaires within 1 month, 7 months, and 18 months after diagnosis. Multilevel models were used to study the trajectory of PA and NA, as measured with the Positive and Negative Affect Schedule (PANAS). Four classes with distinct PA trajectories were identified: low (18.8%), increasing (6.7%), moderate (68.2%), and high (6.3%); 2 trajectories of NA emerged: low (36.3%) and moderate (63.7%). There was no significant association between PA and NA trajectory class probabilities. The average trajectory of PA covaried with levels of goal disturbance and goal reengagement over time, while the average NA trajectory covaried with goal disturbance and goal disengagement. Compared with the general population, our sample of cancer patients suffered from a lack of positive emotions, but not a high presence of negative emotions. About one fifth of patients reported low PA up to 18 months after diagnosis and may benefit from supportive care. Furthermore, the trajectory of PA was independent of that of NA and related with a distinct goal adjustment process (i.e., goal disengagement vs. goal reengagement). This finding indicates the need to tailor psychological care to the nature of the adjustment problem. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Analysis of MINIE2013 Explosion Air-Blast Data

    Energy Technology Data Exchange (ETDEWEB)

    Schnurr, Julie M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Univ. of Hawaii, Manoa, HI (United States); Rodgers, Arthur J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kim, Keehoon [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ford, Sean R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ramirez, Abelardo L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-14

    We report analysis of air-blast overpressure measurements from the MINIE2013 explosive experiments. The MINIE2013 experiment involved a series of nearly 70 near-surface (height-ofburst, HOB, ranging from -1 to +4 m) low-yield (W=2-20 kg TNT equivalent) chemical highexplosives tests that were recorded at local distances (230 m – 28.5 km). Many of the W and HOB combinations were repeated, allowing for quantification of the variability in air-blast features and corresponding yield estimates. We measured canonical signal features (peak overpressure, impulse per unit area, and positive pulse duration) from the air-blast data and compared these to existing air-blast models. Peak overpressure measurements showed good agreement with the models at close ranges but tended to attenuate more rapidly at longer range (~ 1 km), which is likely caused by upward refraction of acoustic waves due to a negative vertical gradient of sound speed. We estimated yields of the MINIE2013 explosions using the Integrated Yield Determination Tool (IYDT). Errors of the estimated yields were on average within 30% of the reported yields, and there were no significant differences in the accuracy of the IYDT predictions grouped by yield. IYDT estimates tend to be lower than ground truth yields, possibly because of reduced overpressure amplitudes by upward refraction. Finally, we report preliminary results on a development of a new parameterized air-blast waveform.

  12. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    2017-05-04

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  13. The Psychometrics of the Mini-K.

    Science.gov (United States)

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  14. Control rod position fault diagnosis and its software realization of pressurized water reactor

    International Nuclear Information System (INIS)

    Chang Zhengke; Shao Dinghong

    2004-11-01

    PLC software is adopted in the Rod Position Monitoring System of QS2NPS. By this software, the position of control rods can be monitored in real time, the abnormal phenomena can be identified immediately, the correctness and timeliness of fault diagnosis are improved remarkably. the identification and recordance of rod position fault, the performance validation of measure channel are realized also. The function and effect of this software are introduced. (authors)

  15. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2016-01-01

    Most orthodontic mini-implants (OMIs) are inserted between dental roots. The prevalence of contacting these structures is high. Such contacts can cause permanent root damage and implant instability. Increased torque levels during implant insertion (the index test) could be a more accurate and

  16. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    Science.gov (United States)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Petty, Brian; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2015-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  17. The diagnosis and management of food allergies. Position paper of the Food Allergy Section the Polish Society of Allergology.

    Science.gov (United States)

    Bartuzi, Zbigniew; Kaczmarski, Maciej; Czerwionka-Szaflarska, Mieczysława; Małaczyńska, Teresa; Krogulska, Aneta

    2017-10-01

    The paper concerns the current position of the Polish Society of Allergology Food Allergy Section on the diagnosis and management of food allergies. The aim of this position is to provide evidence-based recommendations on the diagnosis and management of patients with allergic hypersensitivity to foods. This position statement includes a systematic review of studies in three areas, namely, the epidemiology, diagnosis and management of food allergies. While taking into account the specific Polish setting, in this publication we also used the current European Academy of Allergy and Clinical Immunology (EAACI) position paper and other current position statements, including those of the United States National Institute of Allergy and Infectious Diseases (NIAID).

  18. The diagnosis and management of food allergies. Position paper of the Food Allergy Section the Polish Society of Allergology

    Directory of Open Access Journals (Sweden)

    Zbigniew Bartuzi

    2017-10-01

    Full Text Available The paper concerns the current position of the Polish Society of Allergology Food Allergy Section on the diagnosis and management of food allergies. The aim of this position is to provide evidence-based recommendations on the diagnosis and management of patients with allergic hypersensitivity to foods. This position statement includes a systematic review of studies in three areas, namely, the epidemiology, diagnosis and management of food allergies. While taking into account the specific Polish setting, in this publication we also used the current European Academy of Allergy and Clinical Immunology (EAACI position paper and other current position statements, including those of the United States National Institute of Allergy and Infectious Diseases (NIAID.

  19. Benign paroxysmal positional vertigo in outpatient practice: Diagnosis and treatment

    Directory of Open Access Journals (Sweden)

    N. V. Bestuzheva

    2014-01-01

    Full Text Available Dizziness is one of the common reasons for visits to physicians of various specialties; the data of foreign investigations show that benign paroxysmal positional vertigo (BPPV is most frequently encountered.Objective: to study the causes of dizziness, to analyze the frequency of BPPV and the efficiency of its treatment in outpatient practice.Patients and methods. The investigation enrolled 80 patients, including 55 (68.7% women and 25 (31.3% men, aged 18 to 75 years (mean age 53.8±12.8 years, who complained of dizziness and sought for medical advice in the Therapeutic-and-Diagnostic Unit, A.Ya. Kozhevnikov Clinic of Nervous System Diseases, I.M. Sechenov First Moscow State Medical University.Results. The most common causes of dizziness in outpatient practice were BPPV (46.2% and postural phobic vertigo (35%. The diagnosis of VPPV, if special positional testing (Dix-Hallpike and McClure-Pagnini tests was carried out, was shown to create no significant difficulties. The diagnosis was not established in the majority (97.5% of the patients; effective treatment was performed in one of the patients. Combined treatment, by performing the positional tests and using betaserc for 2 months, led to complete resolution of positional vertigo in most (97.3% patients.Discussion. The findings indicate the efficiency of examining patients with complaints of dizziness, by using the special otoneurological tests to detect BPPV. The purposeful questioning of patients with BPPV can suspect this disease in the majority of cases. Our investigation shows the high efficiency of rehabilitation maneuvers for BPPV, which agrees well with the data of other authors. Physicians’ poor awareness of BPPV among physicians and the high efficiency of its treatment in outpatient practice are noted.

  20. MINI-THESAURUS, Energy Data Base Subject Thesaurus Generator

    International Nuclear Information System (INIS)

    Paulk, J.W.

    2003-01-01

    1 - Description of program or function: MINI-THESAURUS allows the user to subset into highly-specialized 'mini-thesauri' the Energy Data Base (EDB) Subject Thesaurus, which contains the standard vocabulary of indexing terms (descriptors) developed and structured by the Office of Scientific and Technical Information (OSTI) for the building and maintenance of the U.S. Department of Energy (DOE) energy information databases. This structured vocabulary reflects the scope of DOE's research, development, and technological programs and encompasses terminology derived not only from the basic sciences but also from the areas of energy, conservation, safety, environmental impact, and regulation. Entire word blocks may be copied from the primary Subject Thesaurus, from another mini-thesaurus, or both, and subsequently modified through the addition of new terms, the deletion of existing terms, and changes to the internal relationships among the word blocks within the mini-thesaurus to create a new, special-purpose thesaurus. MINI-THESAURUS also provides the ability to copy the entire Subject Thesaurus and to treat the copy as a mini-thesaurus, thus allowing one to examine the effects of major changes to the thesaurus structure without having to modify the primary, on-line Thesaurus. The copy operation also optimizes the Subject Thesaurus structure. An interactive user having update privileges for a specific mini-thesaurus and access to the TeX and PostScript proprietary software can produce the mini-thesaurus in printed publication format. Once the mini-thesaurus has been published, periodic supplements may be generated based on date of entry or change maintained by the Thesaurus software. 2 Restrictions on the complexity of the problem: The system enforces the OSTI rules for Thesaurus development

  1. Spurious RF signals emitted by mini-UAVs

    Science.gov (United States)

    Schleijpen, Ric (H. M. A.); Voogt, Vincent; Zwamborn, Peter; van den Oever, Jaap

    2016-10-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to the sensor community. The detection, classification and identification chain can take advantage of different sensor technologies. Apart from the signatures used by radar and electro-optical sensor systems, the UAV also emits RF signals. These RF signatures can be split in intentional signals for communication with the operator and un-intentional RF signals emitted by the UAV. These unintentional or spurious RF emissions are very weak but could be used to discriminate potential UAV detections from false alarms. The goal of this research was to assess the potential of exploiting spurious emissions in the classification and identification chain of mini-UAVs. It was already known that spurious signals are very weak, but the focus was on the question whether the emission pattern could be correlated to the behaviour of the UAV. In this paper experimental examples of spurious RF emission for different types of mini-UAVs and their correlation with the electronic circuits in the UAVs will be shown

  2. Clock Drawing Test and the diagnosis of amnestic mild cognitive impairment: can more detailed scoring systems do the work?

    Science.gov (United States)

    Rubínová, Eva; Nikolai, Tomáš; Marková, Hana; Siffelová, Kamila; Laczó, Jan; Hort, Jakub; Vyhnálek, Martin

    2014-01-01

    The Clock Drawing Test is a frequently used cognitive screening test with several scoring systems in elderly populations. We compare simple and complex scoring systems and evaluate the usefulness of the combination of the Clock Drawing Test with the Mini-Mental State Examination to detect patients with mild cognitive impairment. Patients with amnestic mild cognitive impairment (n = 48) and age- and education-matched controls (n = 48) underwent neuropsychological examinations, including the Clock Drawing Test and the Mini-Mental State Examination. Clock drawings were scored by three blinded raters using one simple (6-point scale) and two complex (17- and 18-point scales) systems. The sensitivity and specificity of these scoring systems used alone and in combination with the Mini-Mental State Examination were determined. Complex scoring systems, but not the simple scoring system, were significant predictors of the amnestic mild cognitive impairment diagnosis in logistic regression analysis. At equal levels of sensitivity (87.5%), the Mini-Mental State Examination showed higher specificity (31.3%, compared with 12.5% for the 17-point Clock Drawing Test scoring scale). The combination of Clock Drawing Test and Mini-Mental State Examination scores increased the area under the curve (0.72; p Drawing Test did not differentiate between healthy elderly and patients with amnestic mild cognitive impairment in our sample. Complex scoring systems were slightly more efficient, yet still were characterized by high rates of false-positive results. We found psychometric improvement using combined scores from the Mini-Mental State Examination and the Clock Drawing Test when complex scoring systems were used. The results of this study support the benefit of using combined scores from simple methods.

  3. Mini-Sniffer III on Lakebed

    Science.gov (United States)

    1976-01-01

    The third remotely-piloted Mini-Sniffer research vehicle rests on the lakebed adjacent to the Dryden Flight Research Center, Edwards, California. This view shows the wing shape, hydrazine engine, and the tail booms. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  4. Feasibility of mini-tablets as a flexible drug delivery tool.

    Science.gov (United States)

    Mitra, Biplob; Chang, Jessica; Wu, Sy-Juen; Wolfe, Chad N; Ternik, Robert L; Gunter, Thomas Z; Victor, Michael C

    2017-06-15

    Mini-tablets have potential applications as a flexible drug delivery tool in addition to their generally perceived use as multi-particulates. That is, mini-tablets could provide flexibility in dose finding studies and/or allow for combination therapies in the clinic. Moreover, mini-tablets with well controlled quality attributes could be a prudent choice for administering solid dosage forms as a single unit or composite of multiple mini-tablets in patient populations with swallowing difficulties (e.g., pediatric and geriatric populations). This work demonstrated drug substance particle size and concentration ranges that achieve acceptable mini-tablet quality attributes for use as a single or composite dosage unit. Immediate release and orally disintegrating mini-tablet formulations with 30μm to 350μm (particle size d 90 ) acetaminophen and Compap™ L (90% acetaminophen) at concentrations equivalent to 6.7% and 26.7% acetaminophen were evaluated. Mini-tablets achieved acceptable weight variability, tensile strength, friability, and disintegration time at a reasonable solid fraction for each formulation. The content uniformity was acceptable for mini-tablets of 6.7% formulations with ≤170μm drug substance, mini-tablets of all 26.7% formulations, and composite dosage units containing five or more mini-tablets of any formulation. Results supported the manufacturing feasibility of quality mini-tablets, and their applicability as a flexible drug delivery tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Mini-Open Latarjet Procedure for Recurrent Anterior Shoulder Instability

    Directory of Open Access Journals (Sweden)

    Numa Mercier

    2011-01-01

    Full Text Available Anterior shoulder instability is a common problem. The Latarjet procedure has been advocated as an option for the treatment of anteroinferior shoulder instability. The purpose of this paper is to explain our surgical procedure titled “Mini-open Latarjet Procedure.” We detailed patient positioning, skin incision, subscapularis approach, and coracoid fixation. Then, we reviewed the literature to evaluate the clinical outcomes of this procedure.

  6. De validiteit van de cognitieve screening-test en de 'mini-mental state examination' bij een groep oudere ziekenhuispatiënten

    NARCIS (Netherlands)

    Dautzenberg, P. L.; Schmand, B.; Vriens, M. T.; Deelman, B. G.; Hooijer, C.

    1991-01-01

    To study the validity of the cognitive screening test (CST) and of the mini-mental state examination (MMS). Prospective administration of both CST and MMS (in balanced order) by laymen as well as by experienced users, and retrospective comparison of the scores with the clinical diagnosis and with

  7. Mini-marathon groups: psychological "first aid" following disasters.

    Science.gov (United States)

    Terr, L C

    1992-01-01

    Large group counseling sessions for soldiers following battle have been commonly used since World War II. The author conceptualizes and demonstrates how these mini-marathon sessions can be adapted to support all ages and types of civilians involved in disasters. Mini-marathons take about 3 hours and are divided into three sections: story sharing, symptom sharing, and suggestions for self-help, including sharing tales of heroism and survival. After an initial mini-marathon session, a second session may be held emphasizing creativity. The author also describes how mini-marathons can be adapted for therapists who will lead their own sessions.

  8. The use of mini-samples in palaeomagnetism

    Science.gov (United States)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of

  9. Presence of dual diagnosis between users and non-users of licit and illicit drugs in Brazil

    OpenAIRE

    Formiga,Mariana Bandeira; Vasconcelos,Selene Cordeiro; Galdino,Melyssa Kellyane Cavalcanti; Lima,Murilo Duarte da Costa

    2015-01-01

    ABSTRACT Objective Investigate the occurrence of dual diagnosis in users of legal and illegal drugs. Methods It is an analytical, cross-sectional study with a quantitative approach, non-probabilistic intentional sampling, carried out in two centers for drug addiction treatment, by means of individual interviews. A sociodemographic questionnaire, the Alcohol, Smoking and Substance Involvement Screening Test (ASSIST) and the Mini-International Neuropsychiatric Interview (MINI) were used. R...

  10. Fecal specimens preparation methods for PCR diagnosis of human taeniosis

    Directory of Open Access Journals (Sweden)

    Nunes Cáris Maroni

    2006-01-01

    Full Text Available Sample preparation and DNA extraction protocols for DNA amplification by PCR, which can be applied in human fecal samples for taeniasis diagnosis, are described. DNA extracted from fecal specimens with phenol/chloroform/isoamilic alcohol and DNAzol® reagent had to be first purified to generate fragments of 170 pb and 600 pb by HDP2-PCR. This purification step was not necessary with the use of QIAmp DNA stool mini kit®. Best DNA extraction results were achieved after eggs disruption with glass beads, either with phenol/chloroform/isoamilic alcohol, DNAzol® reagent or QIAmp DNA stool mini kit®.

  11. Heat transfer and pressure drop characteristics of mini-fin structures

    International Nuclear Information System (INIS)

    Jiang Peixue; Xu Ruina

    2007-01-01

    Forced convection heat transfer of air and water in bronze and pure copper mini-fin structures and mini-channel structures was investigated experimentally. The mini-fin dimensions were 0.7 mm x 0.2 mm and 0.8 mm x 0.4 mm. The tests included both staggered diamond-shaped and in-line square mini-fin arrangements. The tests investigated the effects of structures, mini-fin dimensions and arrangement, test section materials, and fluid properties on the convection heat transfer and heat transfer enhancement. For the tested conditions, the convection heat transfer coefficient was increased 9-21 fold for water and 12-38 fold for air in the mini-fin structures compared with an empty plate channel. The friction factor and flow resistance in the mini-channel structures and the in-line square mini-fin arrangement were much less than in the staggered diamond-shaped mini-fin arrangement. For the small channel width, W c = 0.2 mm, the convection heat transfer with the in-line square array structure was more intense than with the staggered diamond-shaped structure, the mini-channel structure or the porous media. For the larger channel width, W c = 0.4 mm, the convection heat transfer in the staggered diamond-shaped array structure was more intense than in the others systems while the in-line square structure had the best overall thermal-hydraulic performance

  12. Comparison of retrograde intrarenal surgery and mini-percutaneous nephrolithotomy in management of lower-pole renal stones with a diameter of smaller than 15 mm.

    Science.gov (United States)

    Kirac, Mustafa; Bozkurt, Ömer Faruk; Tunc, Lutfi; Guneri, Cagri; Unsal, Ali; Biri, Hasan

    2013-06-01

    The aim of this study was to compare the outcomes of retrograde intrarenal surgery (RIRS) and miniaturized percutaneous nephrolithotomy (mini-PNL) in management of lower-pole renal stones with a diameter smaller than 15 mm. Between December 2009 and July 2012, the patients with the diagnosis of lower-pole stones were evaluated by ultrasonography, intravenous pyelography and computed tomography. The records of 73 evaluable patients who underwent mini-PNL (n = 37) or RIRS (n = 36) for lower-pole (LP) stones with diameter smaller than 15 mm were reviewed retrospectively. Of the 73 patients, 37 underwent mini-PNL and 36 underwent RIRS. The stone-free rates were 89.1 and 88.8 % for mini-PNL and RIRS groups, respectively. The mean operation time was 53.7 ± 14.5 in the mini-PNL group but 66.4 ± 15.8 in the RIRS group (P = 0.01). The mean fluoroscopy times and hospitalization times were significantly higher in the mini-PNL group. There was no major complication in any patient. RIRS and mini-PNL are safe and effective methods for treatment of LP calculi with a diameter smaller than 15 mm. RIRS is a non-invasive and feasible treatment option, and has also short hospitalization time, low morbidity and complication rate. It may be an alternative of mini-PNL in the treatment LP calculi with smaller than 15 mm.

  13. Assessment of functioning in patients with schizophrenia and schizoaffective disorder with the Mini-ICF-APP: a validation study in Italy.

    Science.gov (United States)

    Pinna, Federica; Fiorillo, Andrea; Tusconi, Massimo; Guiso, Beatrice; Carpiniello, Bernardo

    2015-01-01

    The aim of the study was to evaluate validity of the Italian Mini-ICF-APP (Mini-ICF Rating for Limitations of Activities and Participation in Psychological Disorders) in schizophrenia and related disorders. 74 outpatients affected by schizophrenia or schizoaffective disorders attending a University-based community mental health centre were recruited to the study. All participants underwent comprehensive evaluation using standardized instruments to assess clinical, neurocognitive and functional status. Concurrent validity of Mini-ICF-APP was evaluated and compared to severity scores obtained using the Clinical Global Impression-Schizophrenia scale (CGI-SCH), Positive and Negative Syndrome scale (PANSS), Mini Mental State Examination test (MMSE), Brief Assessment of Cognition in Schizophrenia scale (BACS) and Personal and Social Performance scale (PSP). Construct validity was evaluated by comparing scores obtained at Mini-ICF-APP by remitted versus non-remitted patients, and by recovered versus unrecovered patients. Discriminant validity was evaluated comparing scores on Mini-ICF-APP and Subjective Well-being (SWN) scale. the total score and 12 out of the 13 Mini-ICF-APP items correlated significantly with total score at PSP; Mini-ICF-App total score was moreover significantly correlated with total scores at CGI-SCH, PANSS, MMSE, as well as with several BACS items. Total scores obtained at Mini-ICF-APP were significantly higher among remitted and recovered patients. No relevant correlations were found between scores of Mini-ICF-APP and SWN scales. The total score and 12 out of the 13 Mini-ICF-APP items correlated significantly with total score at PSP; Mini-ICF-App total score was moreover significantly correlated with total scores at CGI-SCH, PANSS, MMSE, as well as with several BACS items. Total scores obtained at Mini-ICF-APP were significantly higher among remitted and recovered patients. No relevant correlations were found between scores of Mini-ICF-APP and SWN

  14. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [ARIES Collaborative, New York, NY (United States); Podorson, David [ARIES Collaborative, New York, NY (United States); Varshney, Kapil [ARIES Collaborative, New York, NY (United States)

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

  15. DIAGNOSIS OF FINANCIAL POSITION BY BALANCE SHEET ANALYSIS - CASE STUDY

    OpenAIRE

    Hada Teodor; Marginean Radu

    2013-01-01

    This study aims to elucidate and to exemplify an important technique for assessing the economic entities, namely the fundamental analysis of the balance sheet, in several significant aspects. The analysis of financial data reported in the balance sheet are, for an economic entity, the basis of a principle diagnosis by determining specific indicators of economic and financial analysis. This analysis aims to provide an insight into the companyâ€(tm)s financial position. The stated aim of this s...

  16. Development of mini-LIA and primary experiments

    International Nuclear Information System (INIS)

    Cheng Cheng; Liao Shuqing; Zheng Shuxin; Lin Yuzheng; Tang Chuanxiang; Jing Xiaobing; Mu Fan; Pan Haifeng; Zhang Kaizhi; Shi Jinshui; Deng Jianjun

    2009-01-01

    Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

  17. Mini lathe machine converted to CNC

    Directory of Open Access Journals (Sweden)

    Alexandru Morar

    2012-06-01

    Full Text Available This paper presents the adaptation of a mechanical mini-lathing machine to a computerized numerical control (CNC lathing machine. This machine is composed of a ASIST mini-lathe and a two-degrees-of-freedom XZ stage designed specifically for this application. The whole system is controlled from a PC using adequate CNC control software.

  18. Circular RNAs as Promising Biomarkers: A mini-review

    Directory of Open Access Journals (Sweden)

    Nadiah Abu

    2016-08-01

    Full Text Available The interest in circular RNAs has resurfaced in the past few years. What was considered as junk for nearly two decades is now one of the most interesting molecules. Circular RNAs are non-coding RNAs that are formed by back-splicing events and have covalently closed loops with no poly-adenylated tails. The regulation of circular RNAs is distinctive and they are selectively abundant in different types of tissues. Based on the current knowledge of circular RNAs, these molecules have the potential to be the next big thing especially as biomarkers for different diseases. This mini-review attempts to concisely look at the biology of circular RNAs, the putative functional activities, the prevalence of circular RNAs, and the possible role of circular RNA as biomarkers for diagnosis or measuring drug response.

  19. Prospects for Antineutrino Running at MiniBooNE

    OpenAIRE

    Wascko, M. O.

    2006-01-01

    MiniBooNE began running in antineutrino mode on 19 January, 2006. We describe the sensitivity of MiniBooNE to LSND-like nuebar oscillations and outline a program of antineutrino cross-section measurements necessary for the next generation of neutrino oscillation experiments. We describe three independent methods of constraining wrong-sign (neutrino) backgrounds in an antineutrino beam, and their application to the MiniBooNE antineutrino analyses.

  20. Measurements of surgeons' exposure to ionizing radiation dose: comparison of conventional and mini C-arm fluoroscopy.

    Science.gov (United States)

    Sung, K H; Min, E; Chung, C Y; Jo, B C; Park, M S; Lee, K

    2016-03-01

    This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient's hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient's hand and a surgeon. Photoluminescence dosimeters were used to measure the equivalent dose by scattered radiation arriving at the thyroid, thymus, and gonad on a whole-body phantom in the position of the surgeon. Equivalent scattered radiation doses were measured in four groups: (1) unshielded conventional C-arm group; (2) unshielded mini C-arm group; (3) lead-shielded conventional C-arm group; and (4) lead-shielded mini C-arm group. Equivalent scattered radiation doses to the unshielded group were significantly lower in the mini C-arm group than those in the conventional C-arm group for all organs. The gonad in the lead-shielded conventional C-arm group showed the highest equivalent dose among operator-susceptible organs, and radiation dose was reduced by approximately 96% compared with that in the unshielded group. Scattered radiation was not detected in any susceptible organ in the lead-shielded mini C-arm group. The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon's susceptible organs and the direct radiation dose to a patient's hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy. © The Author(s) 2015.

  1. Designing a mini subcritical nuclear reactor; Diseno de un mini reactor nuclear subcritico

    Energy Technology Data Exchange (ETDEWEB)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M., E-mail: rafelaescobedo@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Jardin Juarez 147, Col. Centro, 98000 Zacatecas, Zac. (Mexico)

    2015-10-15

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of {sup 239}PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of {sup 239}PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k{sub e}-f{sub f}, the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k{sub eff}, the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons {sup 239}PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k{sub eff} was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k{sub eff} of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five

  2. [The "Mini-ICF-Rating for Mental Disorders (Mini-ICF-P)". A short instrument for the assessment of disabilities in mental disorders].

    Science.gov (United States)

    Linden, M; Baron, S

    2005-06-01

    Supplementary to the description of diseases at symptom level, the International Classification of Functioning, Disability and Health (ICF), edited by the WHO, for the first time enables a systematic description also at the level of disabilities and impairments. The Mini-ICF-Rating for Mental Disorders (Mini-ICF-P) is a short observer rating instrument for the assessment of disabilities, especially with regard to occupational functioning. The Mini-ICF-P was first evaluated empirically in 125 patients of a Department of Behavioural Medicine and Psychosomatics. Parallel-test reliability was r = 0.59. Correlates were found with cognitive and motivational variables and duration of sick leave from work. In summary, the Mini-ICF-P is a quick and practicable instrument.

  3. Mini-percutaneous nephrolithotomy for stones in anomalous-kidneys: a prospective study.

    Science.gov (United States)

    Khadgi, Sanjay; Shrestha, Babu; Ibrahim, Hamdy; Shrestha, Sunil; ElSheemy, Mohammed S; Al-Kandari, Ahmed M

    2017-08-01

    To evaluate safety and efficacy of minipercutaneous nephrolithotomy (Mini-PNL) in management of stones in different types of renal anomalies. Patients with stones ≥2 cm or SWL-resistant stones in anomalous-kidneys treated by Mini-PNL between March 2010 and September 2012 were included prospectively. Mini-PNL was done under regional anesthesia in prone position with fluoroscopic guidance through 18 Fr sheath using semirigid ureteroscope (8.5/11.5 Fr) and pneumatic lithotripter. All patients were followed-up for 2-3 years. Stone-free rate was defined as absence of residual fragments ≥2 mm. Student-T, Mann-Whitney, Chi square (χ 2 ), Fisher-exact, one way ANOVA or Kruskal-Wallis test were used for analysis. Mini-PNL was performed for 59 patients (20 horseshoe, 15 malrotated, 7 polycystic, 13 duplex and 4 ectopic pelvic-kidneys). Mean age was 40.18 ± 12.75 (14-78) years. Mean stone burden was 31.72 ± 21.43 (7.85-141.3) mm 2 . Two tracts were required in 7 (11.9 %) patients. Tubeless Mini-PNL with double-J insertion was performed in all patients except two. Operative time was 50.17 ± 18.73 (15-105) min. Hemoglobin loss was 0.44 ± 0.30 (0-1.4) g/dL. Complications were reported in 15 (25.4 %) patients. No pleural injury, sepsis, perinephric-collection or renal-pelvis perforation were reported. Stone-free rate was 89.8 % (converted to open-surgery in one patient, second-look PNL in two patients, auxiliary SWL in three patients). Stone-free rate improved to 98.3 % after retreatment and auxiliary SWL. Site of puncture was mostly upper calyceal in horseshoe-kidney (80 %), mid calyceal in polycystic-kidney (85.7 %) and lower calyceal in duplex-kidney (46.2 %). Punctures were also significantly infracostal in horseshoe-kidney (100 %) and supracostal in both duplex (53.8 %) and malrotated-kidneys (66.7 %). Mini-PNL is safe for management of stones in anomalous-kidney with SFR comparable to standard-PNL but with less complications.

  4. Mini International Neuropsychiatric Interview (MINI: validação de entrevista breve para diagnóstico de transtornos mentais

    Directory of Open Access Journals (Sweden)

    Amorim Patrícia

    2000-01-01

    Full Text Available Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos, compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas. A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudos de validação do instrumento, realizados na Europa e nos EUA. Métodos: Os estudos 1 (França e 2 (EUA testaram a confiabilidade -entre avaliadores e teste-reteste -da versão DSM-III-R do MINI (n=84, sendo 42 pacientes psiquiátricos de cada centro e sua validade com relação ao CIDI (n=346, sendo 296 pacientes psiquiátricos e 50 controles e ao SCID-P (n=370, sendo 308 pacientes psiquiátricos e 62 controles, respectivamente. O estudo 3 testou a validade de diagnósticos gerados por clínicos gerais usando o MINI (DSM-IV com relação aos diagnósticos clínicos habituais de psiquiatras, em 409 pacientes de centros de atenção primária de quatro países (França, Espanha, Itália e Reino Unido. O estudo 4 testou a confiabilidade entre avaliadores (n=20 pacientes psiquiátricos e a validade dos módulos Transtornos Psicóticos, Depressão e Mania do MINI Plus - DSM IV (n=104 pacientes psiquiátricos com relação a dois critérios de referência: diagnósticos do CIDI e diagnósticos clínicos de psiquiatras. Análises quantitativas (índices de concordância e de validade e qualitativas (razões de discordância foram realizadas. Resultados: Os índices de confiabilidade do MINI (estudos 1 e 2 e do MINI Plus (estudo 4 foram globalmente satisfatórios. Comparados a vários critérios de referência (CIDI, SCID-P, opinião de peritos, em diferentes contextos (unidades psiquiátricas e centros de atenção primária, o MINI e o MINI

  5. PV-hybrid and mini-grid

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 5th European PV-hybrid and mini-grid conference 29th and 30th April, 2010 in Tarragona (Spain) the following lectures were held: (1) Overview of IEA PVPS Task 11 PV-hybrid systems within mini grids; (2) Photovoltaic revolution for deployment in developing countries; (3) Legal and financial conditions for the sustainable operation of mini-grids; (4) EU instruments to promote renewable energies in developing countries; (5) PV hybridization of diesel electricity generators: Conditions of profitability and examples in differential power and storage size ranges; (6) Education suit of designing PV hybrid systems; (7) Sustainable renewable energy projects for intelligent rural electrification in Laos, Cambodia and Vietnam; (8) Techno-economic feasibility of energy supply of remote villages in Palestine by PV systems, diesel generators and electric grid (Case studies: Emnazeil and Atouf villages); (9) Technical, economical and sustainability considerations of a solar PV mini grid as a tool for rural electrification in Uganda; (10) Can we rate inverters for rural electrification on the basis of energy efficiency?; (11) Test procedures for MPPT charge controllers characterization; (12) Energy storage for mini-grid stabilization; (13) Redox flow batteries - Already an alternative storage solution for hybrid PV mini-grids?; (14) Control methods for PV hybrid mini-grids; (15) Partial AC-coupling in mini-grids; (15) Normative issues of small wind turbines in PV hybrid systems; (16) Communication solutions for PV hybrid systems; (17) Towards flexible control and communication of mini-grids; (18) PV/methanol fuel cell hybrid system for powering a highway security variable message board; (19) Polygeneration smartgrids: A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote Areas; (20) Implementation of the Bronsbergen micro grid using FACDS; (21) A revisited approach for the design of PV wind hybrid systems; (22

  6. Rehabilitation of resorbed mandibular ridges using mini implant retained overdentures: A case series with 3 year follow-up

    Directory of Open Access Journals (Sweden)

    Pooja Kumari

    2016-01-01

    Full Text Available With the increasing average life expectancy of human beings, the need to cater geriatric patients is ever increasing. Complete dentures are an indispensable tool in this regard. The loose and unstable lower complete denture owing to residual ridge resorption is one of the most common problems faced by edentulous patients. Dental implant retained overdentures have emerged as an efficient treatment modality for such patients. Though useful, not every patient is a suitable candidate to go for conventional implant-borne prosthesis, limitation being the available bone width. In such cases, mini implants may be used for augmenting the retention of the dentures and improving the quality of life of patients. In this case series, rehabilitation of three compromised cases with mini implant retained overdentures have been described wherein patients are experiencing instability of lower denture due to thin resorbed mandibular ridges. In one of the cases, three mini implants placed in A, C, and E position were splinted using a cemented bar to retain the mandibular denture. The other two cases were rehabilitated using unsplinted ball type one piece mini implants placed in A, C, and E position in one case and B and D position in another case. Though splinted bar design should be preferred but the lack of available vertical space precluded the utilization of bar in other two cases. The results were found to be satisfactory with no complications reported during a follow-up period of over 3 years in all the cases.

  7. The Mini-Cog, Clock Drawing Test, and the Mini-Mental State Examination in a German memory clinic: specificity of separation dementia from depression.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2013-01-01

    The aim of this study was to assess the specificities of the Mini-Cog, the Clock Drawing Test (CDT), and the Mini-Mental State Examination (MMSE) against depression and healthy controls in a German Memory Clinic. Furthermore, we analyzed the specificities of all three screening instruments in dependence of actual depression severity. Data from 142 depressed elderly, 438 dementia patients, and 64 healthy controls were retrospectively analyzed. The CDT and an extraction of the three-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Depression severity was rated by either the Beck Depression Inventory (BDI) or the Geriatric Depression Scale (GDS) depending on the age of the patients. The Mini-Cog achieved a specificity of 79.6% against depressed elderly and 100.0% against healthy subjects (p Mini-Cog and the CDT, but also showed the lowest sensitivity for the detection of dementia. Surprisingly, the depression severity had no effect on the specificity of the Mini-Cog and the CDT, only the MMSE was susceptible for the depression severity. Although the MMSE showed higher specificities, the weighting between the sensitivities and specificities in all tests prove again the Mini-Cog as a short, valid, and sensitive screening tool.

  8. Classification of mini-dimmings associated with extreme ultraviolet eruptions by using graph theory

    Directory of Open Access Journals (Sweden)

    S Bazargan

    2016-09-01

    Full Text Available Coronal dimmings in both micro and macro scales, can be observed by extreme ultraviolet images, recorded from Solar Dynamics Observatory or Atmospheric Imaging Assembly (SDO/AIA. Mini-dimmings are sometimes associated with wave-like brightening, called coronal mass ejections. Here, the sun full disk images with 171 Å wavelenght, cadence of 2.5, and  0.6 arcsec cell size, were taken on 3 March 2012, then the obtained data were analyzed. Using Zernike Moment and Support Vector Machine (SVM, mini dimmings are detected. 538 active region events, 680 coronal hole events and 723 quiet sun events have been recognized using algorithm. The position, time duration and spatial expansion of these events were computed .The eruptive dimmings have a more spatial development than thermal dimmings after eruptions. This is evident in their graph characteristics length. Then, using graph theory, eruptive and thermal mini-dimmings were classified, with 13% error, for 200 dimmings. 68 dimmings were classified as thermal, and 132 as eruptive. To do this, evolution of graph characteristic length were used.

  9. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    Science.gov (United States)

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  10. Low power consumption mini rotary actuator with SMA wires

    Science.gov (United States)

    Manfredi, Luigi; Huan, Yu; Cuschieri, Alfred

    2017-11-01

    Shape memory alloys (SMAs) are smart materials widely used as actuators for their high power to weight ratio despite their well-known low energy efficiency and limited mechanical bandwidth. For robotic applications, SMAs exhibit limitations due to high power consumption and limited stroke, varying from 4% to 7% of the total length. Hysteresis, during the contraction and extension cycle, requires a complex control algorithm. On the positive side, the small size and low weight are eminently suited for the design of mini actuators for robotic platforms. This paper describes the design and construction of a light weight and low power consuming mini rotary actuator with on-board contact-less position and force sensors. The design is specifically intended to reduce (i) energy consumption, (ii) dimensions of the sensory system, and (iii) provide a simple control without any need for SMA characterisation. The torque produced is controlled by on-board force sensors. Experiments were performed to investigate the energy consumption and performance (step and sinusoidal angle profiles with a frequency varying from 0.5 to 10 Hz and maximal amplitude of {15}\\circ ). We describe a transient capacitor effect related to the SMA wires during the sinusoidal profile when the active SMA wire is powered and the antagonist one switched-off, resulting in a transient current time varying from 300 to 400 ms.

  11. Positive predictive value of the infant respiratory distress syndrome diagnosis in the Danish National Patient Registry

    Directory of Open Access Journals (Sweden)

    Thygesen SK

    2013-08-01

    Full Text Available Sandra Kruchov Thygesen, Morten Olsen, Christian Fynbo ChristiansenDepartment of Clinical Epidemiology, Aarhus University Hospital, Aarhus, DenmarkBackground: Infant respiratory distress syndrome (IRDS is the most common respiratory disease in preterm infants, and is associated with considerable morbidity and mortality. Valid data on IRDS are important in clinical epidemiological research.Objectives: The objective of this study was to estimate the positive predictive value (PPV of the IRDS diagnosis registered in the population-based Danish National Patient Registry according to the International Classification of Diseases, 8th and 10th revisions.Methods: Between January 1, 1977 and December 31, 2008, we randomly selected three patients per year, 96 in total, who were registered with an IRDS diagnosis in the Danish National Patient Registry and living in the northern part of Denmark. Data on the infants included information on the presence of predefined clinical symptoms. We defined IRDS as the presence of at least two of four clinical symptoms (tachypnea, retractions or nasal flaring, grunting, and central cyanosis, which had to be present for more than 30 minutes. Using medical record review as the reference standard, we computed the positive predictive value of the registered IRDS diagnosis including 95% confidence intervals (CIs.Results: We located the medical record for 90 of the 96 patients (94%, and found an overall PPV of the IRDS diagnosis of 81% (95% CI 72%–88%. This did not vary substantially between primary and secondary diagnoses. The PPV was higher, at 89% (95% CI 80%–95%, for preterm infants born before 37 weeks of gestation.Conclusion: The PPV of the IRDS diagnosis in the Danish National Patient Registry is reasonable when compared with symptoms described in the corresponding medical records. The Danish National Patient Registry is a useful data source for studies of IRDS, particularly if restricted to preterm infants

  12. Functional Movements in Japanese Mini-Basketball Players

    Directory of Open Access Journals (Sweden)

    Kuzuhara Kenji

    2018-03-01

    Full Text Available Functional movement screen (FMS has been used to establish normative data and determine potential injury risk for young adults and athletes, but there are few data in elementary school-age children. The purpose of this study was to establish fundamental values for the FMS in elementary school-age mini-basketball players. Secondary purposes were to examine relationships between functional movement patterns and age, peak height velocity (PHV, and body mass index (BMI, and to compare functional movement patterns between boys and girls and between individuals with and without a history of injury. The mean composite FMS score was 16.5 ± 2.2 (16.5 ± 2.4 for boys, 16.5 ± 1.7 for girls. The composite FMS score was positively correlated with age (r = .312 and negatively correlated with the BMI (r = − .371. However, the FMS score was not correlated with PHV or with PHV age. The FMS score was not different between boys and girls or between individuals who reported a previous injury and those who did not. However, boys in the mini-basketball teams performed better than girls on the trunk stability push-up and rotary stability tests. Age and the body mass index were significantly associated with better and poorer functional movement, respectively.

  13. Under-diagnosis of alcohol-related problems and depression in a family practice in Japan

    Directory of Open Access Journals (Sweden)

    Yamada Kenshi

    2008-09-01

    Full Text Available Abstract Aim The aim of this survey was to assess the accuracy of a family physician's diagnosis of depression and alcoholism. Methods Consecutive new adult patients attending a family practice in Japan between April 2004 and August 2006 were enrolled. Excluded were those with dementia or visual disturbance, and emergency cases. Participants completed a questionnaire regarding their complaints and socio-demographics. A research nurse conducted the Japanese version of the Mini-International Neuropsychiatric Interview (J-MINI in the interview room. The doctor independently performed usual practice and recorded his own clinical diagnoses. A researcher listed the clinical diagnoses and complaints, including J-MINI or clinically-diagnosed alcoholism and depression, using the International Classifications for Primary Care, Second Edition (ICPC-2 and calculated kappa statistics between the J-MINI and clinical diagnoses. Results Of the 120 adult first-visit patients attending the clinics, 112 patients consented to participate in the survey and were enrolled. Fifty-one subjects were male and 61 female, and the average age was 40.7 ± 13.2 years. Eight alcohol-related disorders and five major depressions were diagnosed using the J-MINI, whereas no cases of alcoholism and eight depressions were diagnosed by the physician. Clinically overlooked patients tended to have acute illnesses like a common cold. Concordance between the clinical and research diagnosis was achieved only for three episodes of Major depression, resulting in a kappa statistic of 0.43. Conclusion Although almost half of the major depressions were identified, all alcoholism was missed. A mental health screening instrument might be beneficial in family practice, especially to detect alcoholism.

  14. Insertion torque recordings for the diagnosis of contact between orthodontic mini implants and dental roots: protocol for a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, R.; Ladu, L.; Ronchi, L.; Di Girolama, N.; de Lange, J.; Roberts, N.; Plüddemann, A.

    2015-01-01

    Background Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of

  15. Validation and cultural adaptation of the Arabic versions of the Mini-Mental Status Examination - 2 and Mini-Cog test.

    Science.gov (United States)

    Albanna, Mohammad; Yehya, Arij; Khairi, Abdalla; Dafeeah, Elnour; Elhadi, Abdelsalam; Rezgui, Lamia; Al Kahlout, Shahada; Yousif, Adil; Uthman, Basim; Al-Amin, Hassen

    2017-01-01

    The elderly population is increasing around the world, and the prevalence of dementia increases with age. Hence, it is expected that the number of people with dementia will increase significantly in the coming years. The Mini-Mental Status Examination - 2 (MMSE-2) and Mini-Cog are widely used tests to screen for dementia. These scales have good reliability and validity and are easy to administer in clinical and research settings. The purpose of this study was to validate the Arabic versions of MMSE-2 and Mini-Cog. These scales were assessed against the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision ( DSM-IV-TR ) criteria for dementia, as the gold standard. The standard versions of the MMSE-2 and Mini-Cog were translated to Arabic following the back-translation method. Then, a trained rater administered these tests to 134 Arab elderly aged >60 years. A physician, blind to the results of these two tests, assessed the participants for vascular dementia or probable Alzheimer's disease, based on the DSM-IV-TR criteria. The sample included 67.2% Qataris. The mean age was 74.86 years (standard deviation =7.71), and 61.9% did not attend school. The mean of the adjusted scores of MMSE-2 based on age and education level was 19.60 (standard deviation =6.58). According to DSM-IV-TR , 17.2% of the participants had dementia. Sensitivity and specificity of the MMSE-2 and the Mini-Cog together were 71.4% and 61.6%, respectively, which were better than those of each test alone. Together, the Arabic versions of MMSE-2 and Mini-Cog are good screening tools for cognitive impairment in Arabs.

  16. The Factors of Local Energy Transition in the Seoul Metropolitan Government: The Case of Mini-PV Plants

    Directory of Open Access Journals (Sweden)

    Jae-Seung Lee

    2017-03-01

    Full Text Available As a way of enhancing urban sustainability, Seoul Special City, the capital of South Korea, has shown strong enthusiasm for urban energy transition by tackling climate change and expanding renewable energy. The Seoul Metropolitan Government (SMG has adopted the “One Less Nuclear Power Plant (OLNPP” strategy since April 2012 and specific policy measures, including a mini-photovoltaic (PV plant program, were introduced to facilitate the energy transition. However, varying degrees of success were achieved by 25 district-level local governments (Gu with mini-PV plant programs. This study explored the reason why those local governments showed different levels of performance despite the strong will of municipal government (SMG to implement urban energy transitions through the mini-PV plant program. The tested hypotheses were based on capacity, political context, public awareness and geographical diffusion. The findings indicated that institutional capacity, financial dependence, political orientation and public perception had positively affected the performance of mini-PV plant installation at each district level. Especially, the political will of each district mayor played an important role in the implementation of the policy.

  17. Reasons for mini-implants failure: choosing installation site should be valued!

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-04-01

    Full Text Available Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1 Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2 Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3 Low bone density, low thickness and low alveolar bone volume; 4 Low alveolar cortical bone thickness; 5 Excessive pressure inducing trabecular bone microfracture; 6 Sites of higher anatomical weakness in the mandible and the maxilla; 7 Thicker gingival tissue not considered when choosing the mini-implant.

  18. Diagnosis and Fault-Tolerant Control for Thruster-Assisted Position Mooring System

    DEFF Research Database (Denmark)

    Nguyen, Trong Dong; Blanke, Mogens; Sørensen, Asgeir

    2007-01-01

    Development of fault-tolerant control systems is crucial to maintain safe operation of o®shore installations. The objective of this paper is to develop a fault- tolerant control for thruster-assisted position mooring (PM) system with faults occurring in the mooring lines. Faults in line......'s pretension or line breaks will degrade the performance of the positioning of the vessel. Faults will be detected and isolated through a fault diagnosis procedure. When faults are detected, they can be accommodated through the control action in which only parameter of the controlled plant has to be updated...... to cope with the faulty condition. Simulations will be carried out to verify the advantages of the fault-tolerant control strategy for the PM system....

  19. Psychometric Evaluation of a Dutch Version of the Mini PAS-ADD for Assessing Psychiatric Disorders in Adults with Different Levels of Intellectual Disability

    Science.gov (United States)

    Janssen, R.; Maes, B.

    2013-01-01

    Background: People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. Method: A Dutch version of the Mini PAS-ADD, which is a screening instrument for…

  20. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2015-01-01

    Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of OMIs may

  1. Congenital hypogonadotropic hypogonadism: implications of absent mini-puberty.

    Science.gov (United States)

    Dwyer, Andrew A; Jayasena, Channa N; Quinton, Richard

    2016-06-01

    The phenomenon known as "mini-puberty" refers to activation of the neonatal hypothalamo-pituitary axis causing serum concentrations of gonadotrophins and testosterone (T) to approach adult male levels. This early neonatal period is a key proliferative window for testicular germ cells and immature Sertoli cells. Although failure to spontaneously initiate (adolescent) puberty is the most evident consequence of a defective gonadotropin-releasing hormone (GnRH) neurosecretory network, absent mini-puberty is also likely to have a major impact on the reproductive phenotype of men with congenital hypogonadotrophic hypogonadism (CHH). Furthermore, the phase of male mini-puberty represents a key window-of-opportunity to identify congenital GnRH deficiency (either isolated CHH, or as part of combined pituitary hormone deficiency) in childhood. Among male neonates exhibiting "red flag" indicators for CHH (i.e. maldescended testes with or without cryptorchidism) a single serum sample (between 4-8 weeks of life) can pinpoint congenital GnRH deficiency far more rapidly and with much greater accuracy than dynamic tests performed in later childhood or adolescence. Potential consequences for missing absent mini-puberty in a male neonate include the lack of monitoring of pubertal progression/lack of progression, and the missed opportunity for early therapeutic intervention. This article will review our current understanding of the mechanisms and clinical consequences of mini-puberty. Furthermore, evidence for the optimal clinical management of patients with absent mini-puberty will be discussed.

  2. Virtual laboratory of electrical mini-grids with distributed generation

    International Nuclear Information System (INIS)

    Menezes Ramos, Vanessa; Barros Galhardo, Marcos André; Oliveira Barbosa, Claudomiro Fábio de; Tavares Pinho, João

    2015-01-01

    This paper presents a computing tool called Virtual Laboratory de Minirredes (Virtual Laboratory of Mini-grids). Using the virtual environment of the developed tool, it is possible to make remote connection/disconnection of switches and loads (resistive, inductive, capacitive and non-linear) at strategic points of the electric mini-grid with hybrid distributed generation systems (solar photovoltaic-diesel). The mini-grid has a length of about 1 km and is installed in the test area of the Grupo de Estudios e Desenvolvimento de Alternativas Exergética (GEDAE) of the Universidade Federal do Pará, located in the city of Belém, Pará, Brazil. The developed tool has communication functions with electric parameters transducers and programmable logic controllers (PLCs). This communication enables the opening and closing of contactors, resulting in different settings for the mini-grid. In addition to that, based on the proposed configuration by the user, the real-time operation status of mini-grid is presented in a graphic interface (for example, monitored electric parameters, distributed generators connected, status of disconnected switches, etc.) and the acquired data is stored. The use of the computing tool also focuses on the construction of a database, in order to obtain knowledge about the mini-grid performance under various conditions that can be set, depending on the operational strategy adopted, based on the choice of the layout, loads and power sources used in the mini-grid. (full text)

  3. Mini AERCam Inspection Robot for Human Space Missions

    Science.gov (United States)

    Fredrickson, Steven E.; Duran, Steve; Mitchell, Jennifer D.

    2004-01-01

    The Engineering Directorate of NASA Johnson Space Center has developed a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam free flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35 pound, 14 inch AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, imaging, power, and propulsion subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations including automatic stationkeeping and point-to-point maneuvering. Mini AERCam is designed to fulfill the unique requirements and constraints associated with using a free flyer to perform external inspections and remote viewing of human spacecraft operations. This paper describes the application of Mini AERCam for stand-alone spacecraft inspection, as well as for roles on teams of humans and robots conducting future space exploration missions.

  4. A system and a method for detecting the position of an object

    International Nuclear Information System (INIS)

    Brown, M.H.; Harrison, J.G.

    1982-01-01

    The position of an object e.g. a manipulator, in an enclosure is detected by two video cameras from which signals representative of images in the cameras are supplied to a mini-computer. The mini-computer scans the signals to detect the position of the object in the signals, and relates this position to the spatial coordinates of the object in the enclosure. Means are provided for controlling the movement of the object within the enclosure, which may be a hostile environment e.g. radio-active. (author)

  5. Mini-chamber, an advanced protection concept for NIF

    International Nuclear Information System (INIS)

    Peterson, P.F.; Scott, J.M.

    1996-01-01

    Inertial confinement fusion (ICF) target debris and ablated near-target materials pose the primary threat to the National Ignition Facility (NIF) final optics debris shields, as well as a major challenge in future inertial fusion energy (IFE) power plants. This work discusses a NIF 'mini-chamber,' designed to mitigate the debris threat. Although the NIF base-line design protects against debris using a frost-protected target positioner and refractory first-wall coatings, the mini-chamber provides important flexibility in three areas: debris-shield protection from beyond-design basis shots (i.e. heavy hohlraums, special diagnostics, shields); fielding of large experiments with significant surface ablation; and studying key ablation and gas-dynamics issues for liquid-wall IFE power plants. Key mini-chamber modeling results are presented, followed by discussion of equipment requirements for fielding a NIF mini-chamber. 7 refs., 3 figs

  6. Mini-Implants: New Possibilities in Interdisciplinary Treatment Approaches

    Directory of Open Access Journals (Sweden)

    Biju Sebastian

    2014-01-01

    Full Text Available The introduction of mini-implants has broadened the range of tooth movements possible by fixed appliance therapy alone. The limits of fixed orthodontic treatment have become more a matter of facial appearance than anchorage. Many complex cases which would previously have required surgery or functional appliances can now be treated with fixed appliance therapy using mini-implants. A mutilated dentition case where mini-implants were used to provide anchorage for intrusion of molars and retraction of anterior teeth is reported here to illustrate this point.

  7. Energy efficient mini bars in hotel rooms; Energieffektive minibarer til hotelvaerelser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-12-15

    The project 'Energy-efficient mini bars for hotel rooms' is carried out from February December 2005. The project is financed by Elfor's PSO funds and also by the participants in the project, HORESTA and Teknologisk Institut. Mini bars consume up to 10% of the total electricity costs of a hotel. Therefore, the energy consumption of mini bars has been brought into focus in this project. The existing mini bar market has been analysed and measurements have been carried out on the type of mini bars that are used most often. In that way, energy consumption, net volume, energy efficiency, energy labelling, noise level and cooling capacity have been determined. In the course of the project, mini bars from IndelB, Domestic and Vibocold have been tested. With regard to energy consumption, the test results showed large deviations from the consumption stated by the manufacturer. Only 1 of the 6 tested mini bars received an energy label B - the others were labelled with F or G. Therefore, there is a great potential for developing more energy efficient mini bars. A list covering the energy consumption, energy labelling, noise level etc. of the tested mini bars and a guide to new purchases can be found on HORESTA's homepage www.horesta.dk. (au)

  8. Morphometry, ultrastructure, myosin isoforms, and metabolic capacities of the "mini muscles" favoured by selection for high activity in house mice.

    Science.gov (United States)

    Guderley, Helga; Houle-Leroy, Philippe; Diffee, Gary M; Camp, Dana M; Garland, Theodore

    2006-07-01

    Prolonged selective breeding of mice (Mus musculus) for high levels of voluntary wheel running has favoured an unusual phenotype ("mini muscles"), apparently caused by a single Mendelian recessive allele, in which most hind-limb muscles are markedly reduced in mass, but have increased mass-specific activities of mitochondrial enzymes. We examined whether these changes reflect changes in fibre size, number or ultrastructure in normal and "mini-muscle" mice within the two (of four) selectively bred lines (lab designations L3 and L6) that exhibit the phenotype at generations 26 and 27. In both lines, the gastrocnemius and plantaris muscles are smaller in mass (by >50% and 20%, respectively) in affected individuals. The mass-specific activities of mitochondrial enzymes in the gastrocnemius and plantaris muscles were increased in the mini phenotype in both lines, with stronger effects in the gastrocnemius muscle. In the gastrocnemius, the % myosin heavy chain (MHC) IIb was reduced by 50% in L3 and by 30% in L6, whereas the % MHC IIa and I were higher, particularly in L3. Fibre number in the plantaris muscle did not significantly differ between mini and normal muscles, although muscle mass was a significant positive correlate of fibre number. Small fibres were more abundant in mini than normal muscles in L3. Mitochondrial volume density was significantly higher in mini than normal muscle fibres in L3, but not in L6. Microscopy revealed a surprising attribute of the mini muscles: an abundance of small, minimally differentiated, myofibril-containing cells positioned in a disorderly fashion, particularly in the surface layer. We hypothesise that these unusual cells may be satellite cells or type IIb fibres that did not complete their differentiation. Together, these observations suggest that mice with the mini phenotype have reduced numbers of type IIb fibres in many of their hind-limb muscles, leading to a decrease in mass and an increase in mass-specific aerobic capacity

  9. Technology advanced mini-eyesafe rangefinder (TAMER)

    Science.gov (United States)

    Abousleman, Glen P.; Smeed, Bill

    1998-08-01

    The Technology Advanced Mini-Eyesafe Rangefinder (TAMER) module is a portable, lightweight (7 lbs), hand-held, target determination system. This rapid prototype program involved the integration of a Motorola 68360 microprocessor, electronic compass, laser range finder, GPS, 4 PCMCIA expansion slots, 0.7-inch micro display, digital camera, floating point unit, and various communications interfaces. The CPU computes an absolute target position based on laser range to target, C/VAM azimuth and inclination inputs, and absolute GPS position. This target position is automatically formatted into a standard military surveillance report and stored in local non- volatile memory. The operator can attach to a SINCGARS radio or to any RS232 compatible system (e.g., cellular telephone). To facilitate the above functionality, the TAMER system utilizes various power saving strategies including software- geared power reduction, power supply configuration, external device integration, and incorporation of low-power ICs. Additionally, TAMER utilizes state-of-the-art digital image compression technology. This custom image coder is based on wavelet decomposition and trellis-coded quantization (TCQ). The algorithm enables TAMER to transmit useful imagery over its severely disadvantaged wireless link.

  10. Optimal design of the absolute positioning sensor for a high-speed maglev train and research on its fault diagnosis.

    Science.gov (United States)

    Zhang, Dapeng; Long, Zhiqiang; Xue, Song; Zhang, Junge

    2012-01-01

    This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project.

  11. Optimal Design of the Absolute Positioning Sensor for a High-Speed Maglev Train and Research on Its Fault Diagnosis

    Directory of Open Access Journals (Sweden)

    Junge Zhang

    2012-08-01

    Full Text Available This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project.

  12. Development on mini X-ray diode

    International Nuclear Information System (INIS)

    Jiang Shaoen; Sun Kexu; Peng Nengling; Huang Tianxuan; Cui Yanli; Yi Rongqing; Chen Jiusen

    2004-01-01

    The mini X-ray diode (M-XRD) was developed, and was used in mini soft X-ray spectrometer. Compared with traditional XRD, M-XRD's volume reduces to 1/30. M-XRD's property was experimentally examined on Shenguang II laser facility. The experimental results indicated that the temporal response and sensitivity of M-XRD are basically consistent with traditional XRD. The equivalent circuit of XRD was analyzed, and its response time and linear saturated current were calculated. (authors)

  13. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Science.gov (United States)

    Camacho, Macario; Zaghi, Soroush; Chang, Edward T.; Song, Sungjin A.; Szelestey, Blake; Certal, Victor

    2016-01-01

    Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes) in adult obstructive sleep apnea (OSA) patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review) for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm) or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed. PMID:26925105

  14. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Directory of Open Access Journals (Sweden)

    Macario Camacho

    2016-01-01

    Full Text Available Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes in adult obstructive sleep apnea (OSA patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed.

  15. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  16. The Saint Louis University Mental Status Examination Is Better than the Mini-Mental State Examination to Determine the Cognitive Impairment in Turkish Elderly People.

    Science.gov (United States)

    Kaya, Derya; Isik, Ahmet Turan; Usarel, Cansu; Soysal, Pinar; Ellidokuz, Hulya; Grossberg, George T

    2016-04-01

    Presence of detailed screening instruments to detect cognitive impairment in the older adults' culture and language is very essential. The Saint Louis University Mental Status Examination (SLUMS) is one of cognitive screening scales used. The aim of the study was to establish the validity and reliability of the Turkish version of SLUMS (SLUMS-T). Two hundred seventy-four participants aged 60 years and older admitted to our geriatric clinic were screened for cognitive impairment using SLUMS-T and Mini-Mental State Examination. Internal consistency was analyzed with Cronbach α test. Area under curves of receiver operating characteristic analyses were used to test the predictive accuracy of the SLUMS-T for detecting amnestic mild cognitive impairment (aMCI) and Alzheimer disease (AD) to set an appropriate cut-off point. The SLUMS-T scores were positively correlated with the Mini-Mental State Examination scores of the patients with aMCI and patients with AD and controls (r = 0.687, P < .001; r = 0.880, P < .001; respectively). Internal consistency of the SLUMS-T was Cronbach α = 0.85. It was found that SLUMS-T with a cut-off point of 23 had a sensitivity of 66.6% and a specificity of 72.3% for the diagnosis of aMCI, and with a cut-off point of 20 had a sensitivity of 83.8% and a specificity of 87.3% for the diagnosis of AD. SLUMS-T was demonstrated to have sufficient validity and reliability to evaluate cognitive impairment including MCI among Turkish elderly people. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. All rights reserved.

  17. Berkeley mini-collider

    International Nuclear Information System (INIS)

    Schroeder, L.S.

    1984-06-01

    The Berkeley Mini-Collider, a heavy-ion collider being planned to provide uranium-uranium collisions at T/sub cm/ less than or equal to 4 GeV/nucleon, is described. The central physics to be studied at these energies and our early ideas for a collider detector are presented

  18. Perlindungan Hukum Hak Kekayaan Intelektual (Hki) Dalam Waralaba Retail Mini Market Di Yogyakarta Mini Market Di Yogyakarta

    OpenAIRE

    Hariyanto Hariyanto, S.H., M.KN

    2009-01-01

    The Law Protection Intellectual Property Right in Mini Market Retail Franchise in YogyakartaFranchise business is more happening in Indonesia. This fast development indicates an interesting investment which on the same time helps the business subjects in starting their own business with a low risk. The franchise business which commonly stable is retail business. One of retail business which serves the main needs and daily needs is mini market Alfamart and Indomaret.This research aims to ident...

  19. Elevated Radiation Exposure Associated With Above Surface Flat Detector Mini C-Arm Use.

    Science.gov (United States)

    Martin, Dennis P; Chapman, Talia; Williamson, Christopher; Tinsley, Brian; Ilyas, Asif M; Wang, Mark L

    2017-11-01

    This study aims to test the hypothesis that: (1) radiation exposure is increased with the intended use of Flat Surface Image Intensifier (FSII) units above the operative surface compared with the traditional below-table configuration; (2) this differential increases in a dose-dependent manner; and (3) radiation exposure varies with body part and proximity to the radiation source. A surgeon mannequin was seated at a radiolucent hand table, positioned for volar distal radius plating. Thermoluminescent dosimeters measured exposure to the eyes, thyroid, chest, hand, and groin, for 1- and 15-minute trials from a mini C-arm FSII unit positioned above and below the operating surface. Background radiation was measured by control dosimeters placed within the operating theater. At 1-minute of exposure, hand and eye dosages were significantly greater with the flat detector positioned above the table. At 15-minutes of exposure, hand radiation dosage exceeded that of all other anatomic sites with the FSII in both positions. Hand exposure was increased in a dose-dependent manner with the flat detector in either position, whereas groin exposure saw a dose-dependent only with the flat detector beneath the operating table. These findings suggest that the surgeon's hands and eyes may incur greater radiation exposure compared with other body parts, during routine mini C-arm FSII utilization in its intended position above the operating table. The clinical impact of these findings remains unclear, and future long-term radiation safety investigation is warranted. Surgeons should take precautions to protect critical body parts, particularly when using FSII technology above the operating with prolonged exposure time.

  20. Orthodontic mechanics using mini-implant measured by FBG

    Science.gov (United States)

    Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-07-01

    The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.

  1. Maximum atmosphere at the Mini Atomiades

    CERN Multimedia

    Rachel Bray, Atomiades organizer team

    2016-01-01

    CERN Clubs Coordination Committee and CERN Staff Association host the ASCERI Mini Atomiades June 2016.   The CERN team won the tennis tournament for the Mini Atomiades 2016. (Photo: Erwin Van Hove) Over 180 participants from 10 different European Scientific Research Institutes came together on the first weekend of June in Divonne-les-Bains to take part in the ASCERI Sport & Science Mini Atomiades. Sports men and women from Belgium, Germany, France, Hungary, Russia and Switzerland battled it out in four different tournaments for medals, cups and, above all, lots of fun. The four disciplines included football, golf, tennis and a 10km race. CERN was victorious in tennis, golf and the men's and women's 10km, and despite the CERN football team putting up an excellent fight against some very strong teams they came almost last (we cannot win everything, can we?). But CERN were the clear winners for team spirit, community and camaraderie, as confirmed by all the comp...

  2. Pre-Hospital Fast Positive Cases Identified by DFB Ambulance Paramedics – Final Clinical Diagnosis

    LENUS (Irish Health Repository)

    Feeney, A

    2016-04-01

    Ischaemic stroke clinical outcomes are improved by earlier treatment with intravenous thrombolysis. An existing pathway at the Mater University Hospital for assessment of suspected acute stroke in the Emergency Department was updated, aiming to shorten ‘door to needle time’. This study examines the final clinical diagnosis of Dublin Fire Brigade Ambulance Paramedic identified Face Arm Speech Test (FAST) positive patients presenting to the Emergency Department over a 7 month period. A retrospective analysis was carried out of 177 consecutive FAST positive patients presenting between March and November 2014. The final clinical diagnosis was acute stroke in 57.1% (n=101) of patients. Of these, 76 were ischaemic strokes of whom 56.5% (n=43) were thrombolysed. In the pre-hospital setting Ambulance Paramedics can identify, with reasonable accuracy, acute stroke using the FAST test. Over half of the ischaemic stroke patients presenting via this pathway can be treated with intravenous thrombolysis

  3. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  4. Mini-mental state exam for children (MMC) in children with hemiplegic cerebral palsy.

    Science.gov (United States)

    Moura, Ricardo; Andrade, Peterson Marco Oliveira; Fontes, Patrícia Lemos Bueno; Ferreira, Fernanda Oliveira; Salvador, Larissa de Souza; Carvalho, Maria Raquel Santos; Haase, Vitor Geraldi

    2017-01-01

    Cognitive impairment is frequent in cerebral palsy (CP) and there is a lack of multiprofessional screening instruments. The aim of this study was to investigate the utility of the Mini-Mental State Examination for Children (MMC), an adapted version of the Mini-Mental State Examination, in screening for cognitive impairments in children with CP. We assessed 397 Brazilian children, 310 with typical development and 87 with CP (hemiplegic and quadriplegic forms), aged 5-16 years. Association between the MMC and general intelligence was assessed by the Colored Progressive Matrices instrument. Psychometric indexes for the MMC were adequate. ROC analyses revealed effective diagnostic accuracy in all ages assessed. Cut-off values are reported. Major difficulties on the MMC were observed in children with CP, particularly individuals with the quadriplegic form. Moreover, the MMC showed moderate correlation with the intelligence test, and was reliable in discriminating, among clinical cases, those with poorer cognitive abilities. The MMC could be useful as a multiprofessional screening instrument for cognitive impairment in children with hemiplegic CP. Results of the MMC in quadriplegic CP children should be interpreted with caution. Diagnosis should be confirmed by further psychological testing.

  5. A Validation Study of the Web Screening Questionnaire (WSQ) Compared With the Mini-International Neuropsychiatric Interview-Plus (MINI-Plus)

    Science.gov (United States)

    Giltay, Erik J; Carlier, Ingrid VE; van Vliet, Irene M; van Hemert, Albert M; Zitman, Frans G

    2017-01-01

    Background There is a need for brief screening methods for psychiatric disorders in clinical practice. This study assesses the validity and accuracy of a brief self-report screening questionnaire, the Web Screening Questionnaire (WSQ), in detecting psychiatric disorders in a study group comprising the general population and psychiatric outpatients aged 18 years and older. Objective The aim of this study was to investigate whether the WSQ is an adequate test to screen for the presence of depressive and anxiety disorders in clinical practice. Methods Participants were 1292 adults (1117 subjects from the general population and 175 psychiatric outpatients), aged 18 to 65 years. The discriminant characteristics of the WSQ were examined in relation to the (“gold standard”) Mini-International Neuropsychiatric Interview-Plus (MINI-Plus) disorders, by means of sensitivity, specificity, area under the curve (AUC), and positive and negative predictive values (PPVs, NPVs). Results The specificity of the WSQ to individually detect depressive disorders, anxiety disorders, and alcohol abuse or dependence ranged from 0.89 to 0.97 for most disorders, with the exception of post-traumatic stress disorder (0.52) and specific phobia (0.73). The sensitivity values ranged from 0.67 to 1.00, with the exception of depressive disorder (0.56) and alcohol abuse or dependence (0.56). Given the low prevalence of separate disorders in the general population sample, NPVs were extremely high across disorders (≥0.97), whereas PPVs were of poor strength (range 0.02-0.33). Conclusions In this study group, the WSQ was a relatively good screening tool to identify individuals without a depressive or anxiety disorder, as it accurately identified those unlikely to suffer from these disorders (except for post-traumatic stress disorders and specific phobias). However, in case of a positive WSQ screening result, further diagnostic procedures are required. PMID:28851674

  6. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  7. GeMini: The Next-Generation Mechanically-Cooled Germanium Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Burks, M

    2008-11-12

    The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (MINIature GErmanium spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice inspections, border patrol, port monitoring and emergency response, where positive nuclide identification of radioactive materials is required but power and liquid cryogen are not easily available. GeMini weighs 2.75 kg for the basic instrument and 4.5 kg for the full instrument including user interface and ruggedized hermetic packaging. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Three working prototypes have been built and tested in the lab. The measured energy resolution is 3 keV fwhm at 662 keV gamma-rays. This paper will focus on the design and performance of the instrument.

  8. MENINGKATKAN HASIL BELAJAR BOLA VOLI MINI MELALUI TUTOR SEBAYA SISWA SEKOLAH DASAR

    Directory of Open Access Journals (Sweden)

    Efan Murtiyono

    2015-07-01

    Full Text Available The purpose of the study to determine the learning outcome volleyball mini through peer tutoring approach for fourth grade students Sabarwangi District Subdistrict Kajen Pekalongan.Reseach using action research. The subjects used were fourth grade students of SD Negeri 23 Sabarwangi the number of students consisting of 14 boys and 9 student daughter .Tecnic with observations and data collection dokumentasi.Instrumen used in the data collection was obtained from the test results that show student performance when implementation. Based on the above results, it can be concluded that the application of mini volleyball lessons through peer tutoring approach has a positive effect, which can increase the yield student learning that can facilitate students to understand and perform the movement correctly. Suggestion of this study can be used as an alternative learning materials if there were teachers who experience the same learning problems.

  9. [Performance of an abbreviated mini mental examination to detect dementia in older people].

    Science.gov (United States)

    Jiménez, Daniel; Lavados, Manuel; Rojas, Paula; Henríquez, Claudio; Silva, Fernando; Guillón, Marta

    2017-07-01

    The usefulness of the abbreviated Mini-Mental State Examination included in the Chilean Functional assessment of elderly people (MM-SE-EFAM) to detect Dementia has not been determined. To assess the performance of the MMSE-EFAM to detect dementia. We studied a non-probabilistic sample of subjects older than 65 years who had been assessed by the MMSE-EFAM in a Chilean primary care center during a period of 6 months. Patients underwent clinical evaluation by a neurologist blinded to MMSE-EFAM score, to establish the diagnosis of dementia using DSM-IV-TR criteria. Besides, the full Mini-Mental State Examination (MMSE) was applied. The clinical diagnosis of Dementia was established in 13 of the 54 peoples evaluated. MMSE-EFAM had a sensitivity of 30.8% (95% confidence intervals (CI); 9-61.4) and a specificity of 90.2% (95% CI; 76.9%-97.3%), while MMSE had a sensitivity of 84.6% (95% CI; 54.6-98.1) and a specificity of 58.5% (95% CI; 42.1-73.7). In a receiver operating characteristic (ROC) curve analysis, the areas under the curve (AUC) were 0.77 (95% CI; 0.61-0.93) and 0.82 (95% CI; 0.70-0.95) for MMSE-EFAM and MMSE, respectively. Socio-demographic variables did not influence test performance in both cases. MMSE-EFAM has a low sensitivity to detect patients with Dementia and it is not an effective screening tool. These results are in agreement with the evidence and international guidelines that do not support the use of cognitive screening tools to detect dementia in the older general population.

  10. Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants

    OpenAIRE

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 follo...

  11. Peak flow meter with a questionnaire and mini-spirometer to help detect asthma and COPD in real-life clinical practice: a cross-sectional study.

    Science.gov (United States)

    Thorat, Yogesh T; Salvi, Sundeep S; Kodgule, Rahul R

    2017-05-09

    Peak flow meter with questionnaire and mini-spirometer are considered as alternative tools to spirometry for screening of asthma and chronic obstructive pulmonary disease. However, the accuracy of these tools together, in clinical settings for disease diagnosis, has not been studied. Two hundred consecutive patients with respiratory complaints answered a short symptom questionnaire and performed peak expiratory flow measurements, standard spirometry with Koko spirometer and mini-spirometry (COPD-6). Spirometry was repeated after bronchodilation. Physician made a final diagnosis of asthma, chronic obstructive pulmonary disease and others. One eighty nine patients (78 females) with age 51 ± 17 years with asthma (115), chronic obstructive pulmonary disease (33) and others (41) completed the study. "Breathlessness > 6months" and "cough > 6months" were important symptoms to detect obstructive airways disease. "Asymptomatic period > 2 weeks" had the best sensitivity (Sn) and specificity (Sp) to differentiate asthma and chronic obstructive pulmonary disease. A peak expiratory flow of meter with few symptom questions can be effectively used in clinical practice for objective detection of asthma and chronic obstructive pulmonary disease, in the absence of good quality spirometry. Mini-spirometers are useful in detection of obstructive airways diseases but FEV 1 measured is inaccurate. DIFFERENTIATING CONDITIONS IN POORLY-EQUIPPED SETTINGS: A simple questionnaire and peak flow meter measurements can help doctors differentiate between asthma and chronic lung disease. In clinical settings where access to specialist equipment and knowledge is limited, it can be challenging for doctors to tell the difference between asthma and chronic obstructive pulmonary disease (COPD). To determine a viable alternative method for differentiating between these diseases, Rahul Kodgule and colleagues at the Chest Research Foundation in Pune, India, trialed a simplified version

  12. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...... of communicative and cooperative skills and 2) whether mini-CEX would provide reproducible data. MATERIAL AND METHODS: Twenty-one residents were evaluated by mini-CEX by trained observers. Seventeen residents had at least two observations within a short period of time and these data were used to estimate the mini...

  13. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    International Nuclear Information System (INIS)

    Hantao Ji

    2004-01-01

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers

  14. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    Energy Technology Data Exchange (ETDEWEB)

    Hantao Ji

    2004-02-27

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers.

  15. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  16. The diagnosis of a fully flexed neck position MRI diagnosis in juvenile muscular atrophy of the distal upper extremity

    International Nuclear Information System (INIS)

    Liu Huaijun; Li Caiying; He Dan; Chi Chen; Cui Caixia; Huang Boyuan; Wang Guoshi; Zhu Qingfeng

    2006-01-01

    Objective: To investigate the value of the diagnosis of MRI during neck flexion in juvenile muscular atrophy of the distal upper extremity. Methods: Five young male patients (mean age 21 years old) with clinical and electrophysiological alterations were performed MR examination with routine neck position and a fully flexed neck position. Eight age-match young men were examined as control subjects. SE T 1 WI, T 2 WI, Fluid-attenuated inversion recovery (FLAIR) sequences were scanned. Results: A distinctive finding in the disorder was forward displacement of the cervical dural sac, compressive flattening of the lower cervical cord during neck flexion and flow void in the posterior epidural space. The forward displacement was significantly greater in patients than in age-matched control subjects. Conclusion: Flexed neck position MRI is helpful to find radiological abnormalities of the lower cervical dural sac and spinal cord, which were combined with clinical disorder to diagnose juvenile muscular atrophy of the distal upper extremity. (authors)

  17. A study of the flow boiling heat transfer in an annular heat exchanger with a mini gap

    Directory of Open Access Journals (Sweden)

    Musiał Tomasz

    2017-01-01

    Full Text Available In this paper the research on flow boiling heat transfer in an annular mini gap was discussed. A one- dimensional mathematical approach was proposed to describe stationary heat transfer in the gap. The mini gap 1 mm wide was created between a metal pipe with enhanced exterior surface and an external tempered glass pipe positioned along the same axis. The experimental test stand consists of several systems: the test loop in which distilled water circulates, the data and image acquisition system and the supply and control system. Known temperature distributions of the metal pipe with enhanced surface and of the working fluid helped to determine, from the Robin boundary condition, the local heat transfer coefficients at the fluid - heated surface contact. In the proposed mathematical model it is assumed that the cylindrical wall is a planar multilayer wall. The numerical results are presented on a chart as function of the heat transfer coefficient along the length of the mini gap.

  18. Taman Mini Indonesia Indah sebagai Bagian dari Fenomena Taman Budaya Dunia

    Directory of Open Access Journals (Sweden)

    Anak Agung Ayu Wulandari

    2012-10-01

    Full Text Available Cultural display in an open space or known as cultural parks appears rapidly as a worldwide phenomenon. From the European model which has a strong educational value, to the Asian parks which not only has educational function, but also has recreational purposes. So many types and characteristics of these parks, researches give them different names, thodse are Open-air museums, Ethnographic Theme Parks or even Theme Parks. Taman Mini Indonesia Indah as a part of this phenomenon was built first and foremost for educational purposes, therefore Taman Mini can be considered as an open-air museum. However, since Taman Mini also has recreational purposes, others can argue that Taman Mini is a theme park. Qualitative method will be used for this research, through observation to Taman Mini Indonesia Indah, followed by extensive literature review. With these data along with a table which points out the distinction between museum and theme parks. It can  be concluded that Taman Mini is a Theme Park.   

  19. Refining MARGINS Mini-Lessons Using Classroom Observations

    Science.gov (United States)

    Iverson, E. A.; Manduca, C. A.; McDaris, J. R.; Lee, S.

    2009-12-01

    One of the challenges that we face in developing teaching materials or activities from research findings is testing the materials to determine that they work as intended. Traditionally faculty develop material for their own class, notice what worked and didn’t, and improve them the next year. However, as we move to a community process of creating and sharing teaching materials, a community-based process for testing materials is appropriate. The MARGINS project has piloted such a process for testing teaching materials and activities developed as part of its mini-lesson project (http://serc.carleton.edu/margins/index.html). Building on prior work developing mechanisms for community review of teaching resources (e.g. Kastens, 2002; Hancock and Manduca, 2005; Mayhew and Hall, 2007), the MARGINS evaluation team developed a structured classroom observation protocol. The goals of field testing are to a) gather structured, consistent feedback for the lesson authors based on classroom use; b) guide reviewers of these lessons to reflect on research-based educational practice as a framework for their comments; c) collect information on the data and observations that the reviewer used to underpin their review; d) determine which mini-lessons are ready to be made widely available on the website. The protocol guides faculty observations on why they used the activity, the effectiveness of the activity in their classroom, the success of the activity in leading to the desired learning, and what other faculty need to successfully use the activity. Available online (http://serc.carleton.edu/margins/protocol.html), the protocol can be downloaded and completed during instruction with the activity. In order to encourage review of mini-lessons using the protocol, a workshop focused on review and revision of activities was held in May 2009. In preparation for the workshop, 13 of the 28 participants chose to field test a mini-lesson prior to the workshop and reported that they found this

  20. [CONSISTENCY OF MINI NUTRITIONAL ASSESSMENT TO IDENTIFY SARCOPENIA IN OLDER ADULTS IN NURSING HOMES IN BOGOTA, COLOMBIA].

    Science.gov (United States)

    Díaz Muñoz, Gustavo Alfonso; Cárdenas Zuluaga, Diana María; Mesa Jimenez, Alfonso

    2015-07-01

    malnutrition and sarcopenia, which have similar physiological mechanisms and are both responsible for adverse health outcomes, are highly prevalent in the elderly. to measure the consistency of the MNA with the diagnosis of sarcopenia in older adults. cross-sectional study of consistency in four nursing homes in Bogotá. The nutritional screening and nutritional assessment were made with the Mini Nutritional Assessment in its long form; the diagnosis of sarcopenia was done with the algorithm and the breakpoints of the European Consensus (EWGSOP). Pearson Chi2, Mann-Whitney and consistency by Cohen's kappa coefficient. we included 108 patients, 62% women, mean age 80.4 years (SD 7.7). The prevalence of sarcopenia, malnutrition and risk of malnutrition were 38.9%, 33.3% and 2.8% respectively. The concordance of the MNA with the diagnosis of sarcopenia was slight (kappa 0.1908 95% CI 0.0025 to 0.3791, p sarcopenia, suggesting that it is not an appropriate tool for the diagnosis of sarcopenia in older institutionalized adults. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  1. Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children

    DEFF Research Database (Denmark)

    Ortqvist, Maria; Moström, Eva B; Roos, Ewa M.

    2011-01-01

    PURPOSE: The purposes of this study were to evaluate reliability of the Single-limb mini squat test (a dynamic measure of medio-lateral knee position) and the Quadriceps-angle (Q-angle) (a static measure of medio-lateral knee position), present paediatric reference values of the Q......-angle measurements was found. Reference values for the Q-angle (mean 13.5° (1.9)-15.3° (2.8)) varies with age and gender. No associations were found between dynamic and static measures. CONCLUSIONS: The Single-limb mini squat test showed a moderate reliability and the Q-angle showed a fair to moderate reliability......-angle, and evaluate the association between the tests. METHODS: Two hundred and forty-six healthy children (9-16 years) were included (intra/inter-rater reliability for Q-angle (n = 37/85) and for Single-limb mini squat test (n = 33/28)). Dynamic medio-lateral knee position was assessed by the Single-limb mini squat...

  2. Noninvasive prenatal diagnosis. Use of density gradient centrifugation, magnetically activated cell sorting and in situ hybridization

    DEFF Research Database (Denmark)

    Campagnoli, C; Multhaupt, H A; Ludomirski, A

    1997-01-01

    OBJECTIVE: To develop a noninvasive method suitable for clinical prenatal diagnosis. STUDY DESIGN: Fetal nucleated erythrocytes were separated from peripheral blood of 17 healthy pregnant women using small magnetically activated cell sorting columns (MiniMACS) following density gradient centrifug...

  3. A mini-microscope for in situ monitoring of cells.

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R; Hamilton, Geraldine A; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E; Khademhosseini, Ali

    2012-10-21

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost.

  4. Complete overdentures retained by mini implants: A systematic review.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  5. The Mini-Cog versus the Mini-Mental State Examination and the Clock Drawing Test in daily clinical practice: screening value in a German Memory Clinic.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2012-05-01

    The aim of this study was to compare the screening value of the Mini-Cog, Clock Drawing Test (CDT), Mini-Mental State Examination (MMSE) and the algorithm MMSE and/or CDT to separate elderly people with dementia from healthy depending on test time, type and severity of dementia, and demographic variables in a German Memory Clinic. Data from a heterogeneous patient sample and healthy participants (n = 502) were retrospectively analyzed. Of the 438 patients with dementia, 49.1% of the dementia diagnoses were Alzheimer's dementia and 50.9% were non-Alzheimer's dementia. Sixty-four participants were classified as cognitively unimpaired. The CDT and an extraction of the 3-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Overall, the Mini-Cog showed significantly higher discriminatory power (86.8%) than the MMSE (72.6% at a cut-off ≤ 24 and 79.2% at ≤ 25, respectively) and CDT (78.1%) (each p 0.05). The specificity of the Mini-Cog (100.0%) was similar to that of the MMSE (100.0% for both cut-offs) and CDT (96.9%) (p = 0.154). For all age and educational groups the Mini-Cog outmatched the CDT and MMSE, and was less affected by education than MMSE and less susceptible for the dementia stage than the CDT. The Mini-Cog proved to have superior discriminatory power than either CDT or MMSE and is demonstrated to be a valid "short" screening instrument taking 3 to 4 minutes to administer in the geriatric setting.

  6. A universal mini-vector and an annealing of PCR products (APP)-based cloning strategy for convenient molecular biological manipulations.

    Science.gov (United States)

    Liu, Xia; Li, Tuoping; Hart, Darren J; Gao, Song; Wang, Hongling; Gao, Herui; Xu, Shumin; Zhang, Yifeng; Liu, Yifei; An, Yingfeng

    2018-03-18

    Currently, the most widely used strategies for molecular cloning are sticky-end ligation-based cloning, TA cloning, blunt-end ligation-based cloning and ligase-independent cloning. In this study we have developed a novel mini-vector pANY1 which can simultaneously meet the requirements of all these cloning strategies. In addition, the selection of appropriate restriction digestion sites is difficult in some cases because of the presence of internal sites. In this study, an annealing of PCR products (APP)-based sticky-end cloning strategy was introduced to avoid this issue. Additionally, false positives occur during molecular cloning, which increases the workload of isolating positive clones. The plasmid pANY1 contains a ccdB cassette between multiple cloning sites, which efficiently avoids these false positives. Therefore, this mini-vector should serve as a useful tool with wide applications in biosciences, agriculture, food technologies, etc. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Characterization of surface topography and chemical composition of mini-implants

    OpenAIRE

    Knop, Luegya Amorim Henriques; Soares, Ana Prates; Shintcovsk, Ricardo Lima; Martins, Lidia Parsekian; Gandini Jr., Luiz Gonzaga

    2015-01-01

    Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis ...

  8. Late time CMB anisotropies constrain mini-charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Burrage, C.; Redondo, J.; Ringwald, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Jaeckel, J. [Univ. of Durham, Inst. for Particle Physics Phenomenology (United Kingdom)

    2009-09-15

    Observations of the temperature anisotropies induced as light from the CMB passes through large scale structures in the late universe are a sensitive probe of the interactions of photons in such environments. In extensions of the Standard Model which give rise to mini-charged particles, photons propagating through transverse magnetic fields can be lost to pair production of such particles. Such a decrement in the photon flux would occur as photons from the CMB traverse the magnetic fields of galaxy clusters. Therefore late time CMB anisotropies can be used to constrain the properties of mini- charged particles. We outline how this test is constructed, and present new constraints on mini-charged particles from observations of the Sunyaev-Zel'dovich effect in the Coma cluster. (orig.)

  9. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  10. Mini-Grids for the Base of the Pyramid Market: A Critical Review

    Directory of Open Access Journals (Sweden)

    Subhes C. Bhattacharyya

    2018-04-01

    Full Text Available The lack of access to electricity of more than 1.1 billion people around the world remains a major developmental challenge and Goal 7 of the Sustainable Development Goals (SDG as well as Sustainable Energy for All (SE4ALL have set a target of universal electrification by 2030. Various studies have identified mini-grid-based electrification as a possible solution. There is a growing body of literature available now that has explored the feasibility, practical application and policy interventions required to support mini-grids. Through a review of available literature, this paper explores whether mini-grids can be a solution for the base of the pyramid (BoP market and the challenges faced in deploying mini-grids in such markets. Interventions to support the mini-grid deployment are also discussed. The paper finds that the mini-grids are targeting the BoP market but the business is not attractive in profitability terms and requires financial support. Lack of regulatory clarity and non-coordinated policies affect the financial viability of projects, which requires careful support. Mini-grid electrification has hardly been embedded in rural development agenda and hence they have not contributed significantly to livelihood generation. Careful realignment of policies, regulatory frameworks and support systems can better support mini-grid deployment in developing countries.

  11. Mini-mental state examination as a predictor of mortality among older people referred to secondary mental healthcare.

    Science.gov (United States)

    Su, Yu-Ping; Chang, Chin-Kuo; Hayes, Richard D; Perera, Gayan; Broadbent, Matthew; To, David; Hotopf, Matthew; Stewart, Robert

    2014-01-01

    Lower levels of cognitive function have been found to be associated with higher mortality in older people, particularly in dementia, but the association in people with other mental disorders is still inconclusive. Data were analysed from a large mental health case register serving a geographic catchment of 1.23 million residents, and associations were investigated between cognitive function measured by the Mini-Mental State Examination (MMSE) and survival in patients aged 65 years old and over. Cox regressions were carried out, adjusting for age, gender, psychiatric diagnosis, ethnicity, marital status, and area-level socioeconomic index. A total of 6,704 subjects were involved, including 3,368 of them having a dementia diagnosis and 3,336 of them with depression or other diagnoses. Descriptive outcomes by Kaplan-Meier curves showed significant differences between those with normal and impaired cognitive function (MMSE scoremental health services regardless of a dementia diagnosis. Causal pathways between this exposure and outcome (for example, suboptimal healthcare) need further investigation.

  12. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics.

    Science.gov (United States)

    El-Say, Khalid M; Ahmed, Tarek A; Abdelbary, Maged F; Ali, Bahaa E; Aljaeid, Bader M; Zidan, Ahmed S

    2015-12-01

    This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets) as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1), swelling pressure of the superdisintegrant (X2), and the surface area of Aerosil as a glidant (X3). Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for pre- and post-compression characteristics. The prepared OD-mini-tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2) and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  13. Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.

    Science.gov (United States)

    Anter, Elad; Tschabrunn, Cory M; Contreras-Valdes, Fernando M; Li, Jianqing; Josephson, Mark E

    2015-09-01

    During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVI. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. Re-examining the factor structure and psychometric properties of the Mini-Mental Adjustment to Cancer Scale in a sample of 364 Chinese cancer patients.

    Science.gov (United States)

    Fong, Ted C T; Ho, Rainbow T H

    2015-02-01

    The Mini-Mental Adjustment to Cancer Scale (Mini-MAC) is widely used to evaluate cancer patients' psychological responses. Validation studies of the scale have shown methodological shortcomings and inconsistency in the factor solutions. The aim of this study was to examine the factor structure and psychometric properties of the Mini-MAC. A large sample of 364 Chinese patients with breast or colorectal cancer completed the Mini-MAC and psychosocial measures (general health, perceived stress, anxiety, and depression). Exploratory factor analyses examined the relative fit of two- to six-factor models using robust weighted least square estimation and oblique target rotation. Convergent validity was evaluated via correlations between the Mini-MAC factor scores and the psychosocial outcomes. The five-factor model showed the best model fit and largely replicated the original Mini-MAC's helpless/hopeless (HH), anxious preoccupation (AP), fighting spirit (FS), fatalism (FA), and cognitive avoidance (CA) subscales. The five factors had acceptable reliability (Cronbach's α = 0.67-0.88) and 4-month test-retest reliability (r = 0.45-0.64). HH, AP, and CA were positively associated with the psychosocial outcomes (r = 0.19-0.60). Modest and negative correlations were found between the psychosocial outcomes and FS and FA. The results support the Mini-MAC's original five-factor structure with satisfactory reliability and convergent validity. The results demonstrate that the Mini-MAC is a valid measure for assessing psychological responses in cancer patients.

  15. Accelerated Tooth Movement with Orthodontic Mini-Screws

    Directory of Open Access Journals (Sweden)

    S. Aksakalli

    2017-01-01

    Full Text Available This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-year-old male patient presented Class II malocclusion with maxillary incisor protrusion. Upper first premolars were extracted, and after leveling, accelerated canine distalization started. For pre- and postdistalization times, amount of distalization, periodontal health, and root resorption were assessed. Within the limitations of this case report, micro-osteoperforations with mini-screw have a potential for shortening the treatment time.

  16. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    Science.gov (United States)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  17. Predicting everyday functional abilities of dementia patients with the Mini-Mental State Examination.

    Science.gov (United States)

    Razani, Jill; Wong, Jennifer T; Dafaeeboini, Natalia; Edwards-Lee, Terri; Lu, Po; Alessi, Cathy; Josephson, Karen

    2009-03-01

    The Mini-Mental State Examination is a widely used cognitive screening measure. The purpose of the present study was to assess how 5 specific clusters of Mini-Mental State Examination items (ie, subscores) correlate with and predict specific areas of daily functioning in dementia patients, 61 patients with varied forms of dementia were administered the Mini-Mental State Examination and an observation-based daily functional test (the Direct Assessment of Functional Status). The results revealed that the orientation and attention subscores of the Mini-Mental State Examination correlated most significantly with most functional domains. The Mini-Mental State Examination language items correlated with all but the shopping and time orientation tasks, while the Mini-Mental State Examination recall items correlated with the Direct Assessment of Functional Status time orientation and shopping tasks. Stepwise regression analyses found that among the Mini-Mental State Examination subscores, orientation was the single, best independent predictor of daily functioning.

  18. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  19. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  20. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  1. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  2. Delphi report 1995 on developments in science and technology. Mini Delphi; Delphi-Bericht 1995 zur Entwicklung von Wissenschaft und Technik. Mini-Delphi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    In August 1993 the first German `Delphi Report on Developments in Science and Technology` was published. It was elaborated by the Fraunhofer Institute for System Engineering and Innovation Research (FhG-ISI) in cooperation with the Japanese National Institute of Science and Technology Policy (NISTEP). The `MINI-DELPHI` now completed by FhG-ISI, again in cooperation with NISTEP, is a further development of the Delphi approach in that it is more differentiated in its questions and assessment criteria than its predecessors. `MINI-DELPHI` is not intended as a comprehensive forecast on technology in general but rather focusses on key topics. Its emphasis is on technology demand and the relevance of technologies to social issues. Although the Mini-Delphi study was primarily aimed at further refining the methodology employed, it nevertheless contains a wealth of information and details on circumscript questions. The requisite database is provided by tables on the results of two inquiry rounds among Japanese and German experts. (orig./RHM) [Deutsch] Im August 1993 wurde der erste deutsche `Delphi-Bericht zur Entwicklung von Wissenschaft und Technik` veroeffentlicht. Er war vom Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung (FhG-ISI) in Zusammenarbeit mit dem japanischen National Institute of Science and Technology Policy (NISTEP) erarbeitet worden. Mit dem jetzt vorliegenden `MINI-DELPHI` hat das FhG-ISI - wieder in Zusammenarbeit mit dem NISTEP - den Delphi-Ansatz fortentwickelt und sowohl hinsichtlich der Fragen als auch der Beurteilungskriterien weiter ausdifferenziert. `MINI-DELPHI` bezweckt keine umfassende Technologievorausschau, sondern konzentriert sich auf Schluesselthemen. Im Vordergrund steht der Gedanke des Technikbedarfs und die Relevanz fuer gesellschaftliche Fragestellungen. Obwohl die Mini-Delphi-Studie vorrangig der Weiterentwicklung der Methodik dient, enthaelt sich eine Fuelle von Informationen und Details zu Einzelfragen. Die im Bericht

  3. HIV Positive Diagnosis During Pregnancy Increases Risk of IPV Postpartum Among Women with No History of IPV in Their Relationship.

    Science.gov (United States)

    Groves, Allison K; Reyes, H Luz McNaughton; Moodley, Dhayendre; Maman, Suzanne

    2017-07-24

    There has been limited study of whether and for whom physical intimate partner violence (IPV) is a consequence of an HIV-positive diagnosis. Per the diathesis stress model, the consequences of HIV infection may be worse for women with a history of IPV. We hypothesize that the positive association between HIV diagnosis in pregnancy and postpartum IPV will be exacerbated for women with a history of IPV. Data come from a prospective cohort study with 1015 participants who completed a baseline antenatal and 9-month postpartum visit. Using logistic regression analyses, we found a statistically significant interaction between HIV diagnosis, history of IPV and postpartum IPV (AOR: 0.40, 95% CI 0.17-0.96). The findings were in the opposite direction as expected: HIV-diagnosis was not associated with IPV for women with a history of IPV (AOR: 2.17, 95% CI 1.06, 4.42). However, HIV-positive women without a history of IPV faced more than two times the risk of incident postpartum IPV than HIV-negative women (AOR: 2.17, 95% CI 1.06, 4.42). Interventions to reduce incident and ongoing IPV during the perinatal period are needed.

  4. Designing a mini subcritical nuclear reactor

    International Nuclear Information System (INIS)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M.

    2015-10-01

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of 239 PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of 239 PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k e -f f , the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k eff , the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons 239 PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k eff was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k eff of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five cylinders not met. (Author)

  5. Humanities mini-course curricula for midcareer health professionals at the Penn State Milton S. Hershey Medical Center.

    Science.gov (United States)

    Myers, Kimberly R; George, Daniel R

    2012-08-01

    The field of medical humanities has traditionally focused on medical students and, more recently, on premedical undergraduates. Comparatively little formal humanities pedagogy has been dedicated to midcareer health professionals. To address this lack, the Department of Humanities at the Pennsylvania State University College of Medicine and the Milton S. Hershey Medical Center designed eight annual humanities mini-courses for faculty and staff throughout the college and medical center.These mini-courses fell into four categories: reading, reflection, and discussion; creative expression; technology; and ethics. They were geared toward midcareer health professionals who were seeking new intellectual and creative stimulation and variety in daily routine. They also provided humanities faculty the opportunity to devote attention to topics that capitalize on their professional training and that interest them personally.Participants indicated a high degree of satisfaction with the mini-courses for four principal reasons: (1) learning the tools and methodologies of a new discipline or domain other than biomedicine, (2) using their minds and training in uncustomary ways, (3) forming new alliances with colleagues (which served to lessen the sense of professional isolation), and (4) enjoying a respite from the stressful flow of the workday. Humanities faculty facilitators provided more mixed responses but agreed that conducting the mini-courses had been a positive overall experience.Although this article provides a foundational framework for the development of a humanities mini-course series, the authors encourage others to replicate these curricula in other medical settings as an important step toward a robust pedagogy designed for midcareer health care professionals.

  6. Mini-open vacuum-assisted closure therapy with instillation for debilitated and septic patients with pleural empyema.

    Science.gov (United States)

    Sziklavari, Zsolt; Ried, Michael; Neu, Reiner; Schemm, Rudolf; Grosser, Christian; Szöke, Tamas; Hofmann, Hans-Stefan

    2015-08-01

    This prospective study is an evaluation of the mini-open vacuum-assisted closure with instillation (Mini-VAC-Instill) therapy for the treatment of complicated pleural empyema. We investigated septic patients in poor general physical condition (Karnofsky index ≤50%) with multimorbidity and/or immunosuppression who were treated by minimally invasive intrathoracic VAC-Instill therapy without the insertion of an open-window thoracostomy (OWT) between December 2012 and November 2014. All patients underwent mini-thoracotomy with position of a tissue retractor, surgical debridement and local decortication. Surgery was followed by intrathoracic vacuum therapy including periodic instillation using antiseptics. The VAC dressings were changed under general anaesthesia and the chest wall was closed during the same hospital stay. All patients received systemic antibiotic therapy. Fifteen patients (13 males, median age: 71 years) underwent intrathoracic Mini-VAC-Instill dressings for the management of pleural empyema without bronchopleural fistula. The median length of vacuum therapy was 9 days (5-25 days) and the median number of VAC changes per patient was 1 (1-5). In-hospital mortality was 6.7% (n = 1) and was not related to Mini-VAC-Instill therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in 85.7% of surviving patients (12 of 14). After the follow-up at an average of 13.2 months (range, 3-25 months), we observed recurrence once, 21 days after discharge. Two patients died in the late postoperative period (Day 43 and Day 100 after discharge) of fulminant urosepsis and carcinoma-related multiorgan failure, respectively. Analysis of the follow-up interviews in the outpatient clinic showed a good quality of life and a subjectively good long-term aesthetic result. Mini-VAC-Instill therapy is an upgrade of Mini-VAC, which guarantees the advantage of an open treatment, including flushing but without OWT. This

  7. Internal Structure of Mini-CEX Scores for Internal Medicine Residents: Factor Analysis and Generalizability

    Science.gov (United States)

    Cook, David A.; Beckman, Thomas J.; Mandrekar, Jayawant N.; Pankratz, V. Shane

    2010-01-01

    The mini-CEX is widely used to rate directly observed resident-patient encounters. Although several studies have explored the reliability of mini-CEX scores, the dimensionality of mini-CEX scores is incompletely understood. Objective: Explore the dimensionality of mini-CEX scores through factor analysis and generalizability analysis. Design:…

  8. Mini-Digest of Education Statistics, 2008. NCES 2009-021

    Science.gov (United States)

    Snyder, Thomas D.

    2009-01-01

    This publication is the 14th edition of the "Mini-Digest of Education Statistics," a pocket-sized compilation of statistical information covering the broad field of American education from kindergarten through graduate school. The "Mini-Digest" is designed as an easy reference for materials found in much greater detail in the…

  9. Fibrous mini-collagens in hydra nematocysts.

    Science.gov (United States)

    Holstein, T W; Benoit, M; Herder, G V; David, C N; Wanner, G; Gaub, H E

    1994-07-15

    Nematocysts (cnidocysts) are exocytotic organelles found in all cnidarians. Here, atomic force microscopy and field emission scanning electron microscopy reveal the structure of the nematocyst capsule wall. The outer wall consists of globular proteins of unknown function. The inner wall consists of bundles of collagen-like fibrils having a spacing of 50 to 100 nanometers and cross-striations at intervals of 32 nanometers. The fibrils consist of polymers of "mini-collagens," which are abundant in the nematocysts of Hydra. The distinct pattern of mini-collagen fibers in the inner wall can provide the tensile strength necessary to withstand the high osmotic pressure (15 megapascals) in the capsules.

  10. Concerning production and decay of mini black holes

    CERN Document Server

    Hajdukovic, D

    2007-01-01

    In the next few years, theories predicting possibility to create mini black holes will be tested at CERN. Either experimental verification or rejection of these theories is of great scientific importance. There is a large consensus that, if successfully created, these short living mini black holes will decay through thermal (Hawking's) radiation. In the present comment we point out, that under assumption of the gravitational repulsion between matter and antimatter (in short we call it antigravity), thermal radiation may be dominated by a non-thermal radiation (being the consequence of pair creation from the vacuum, by gravitational field, which in the case of antigravity, pushes particles and antiparticles in opposite directions). Thus, the eventual creation of mini black holes may turn to be an unexpected opportunity to test the existence of antigravity.

  11. Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment.

    Science.gov (United States)

    Lee, Jin-Hwa; Choo, Hyeran; Kim, Seong-Hun; Chung, Kyu-Rhim; Giannuzzi, Lucille A; Ngan, Peter

    2011-06-01

    When mini-implants fail during orthodontic treatment, there is a need to have a backup plan to either replace the failed implant in the adjacent interradicular area or wait for the bone to heal before replacing the mini-implant. We propose a novel way to overcome this problem by replacement with a miniplate so as not to interrupt treatment or prolong treatment time. The indications, advantages, efficacy, and procedures for switching from a mini-implant to a miniplate are discussed. Two patients who required replacement of failed mini-implants are presented. In the first patient, because of the proximity of the buccal vestibule to the mini-implant, it was decided to replace the failed mini-implant by an I-shaped C-tube miniplate. In the second patient, radiolucencies were found around the failed mini-implants, making the adjacent alveolar bone unavailable for immediate placement of another mini-implant. In addition, the maxillary sinus pneumatization was expanded deeply into the interradicular spaces; this further mandated an alternative placement site. One failed mini-implant was examined under a scanning electron microscope for bone attachment. Treatment was completed in both patients after replacement with miniplates without interrupting the treatment mechanics or prolonging the treatments. Examination under the scanning electron microscope showed partial bone growth into the coating pores and titanium substrate interface even after thorough cleaning and sterilization. Replacement with a miniplate is a viable solution for failed mini-implants during orthodontic treatment. The results from microscopic evaluation of the failed mini-implant suggest that stringent guidelines are needed for recycling used mini-implants. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  12. Evaluation of mini super computers for nuclear design applications

    International Nuclear Information System (INIS)

    Altomare, S.; Baradari, F.

    1987-01-01

    The evolution of the mini super computers will force changes from the current environment of performing nuclear design calculations on mainframe computers (such as a CRAY) to mini super computers. This change will come about for a number of reasons. First, the mini super computers currently available in the marketplace offer the power and speed comparable to mainframes and can provide the capability to support highly computer intensive calculations. Second, the equipment is physically smaller and can easily be installed and operated without extensive investments in facilities and operations support. Third, the computer capacity can be acquired with as much needed memory, disk, and tape capacity as may be needed. Another reasons is that the performance/cost ratio has increased drastically as hardware costs have decreased. A study was conducted at the Westinghouse Commercial Nuclear Fuel Division (CNFD) to evaluate the mini super computers for use in nuclear core design. As a result of this evaluation, Westinghouse CNFD is offering a combined hardware/software technology transfer package for core design. This package provides the utility designer with a totally dedicated mini super computer comparable in speed to the CRAY 1S with sufficient capacity for a sizable design group to perform the engineering activities related to nuclear core design and operations support. This also assures the utility of being totally compatible with the CNFD design codes, thus assuring total update compatibility

  13. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation of communi......INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...

  14. Prosthetic Rehabilitation of Child Victim of Avulsion of Anterior Teeth with Orthodontic Mini-Implant

    Directory of Open Access Journals (Sweden)

    Natalice Sousa de Oliveira

    2017-01-01

    Full Text Available The treatment of choice in cases of avulsed permanent teeth is the immediate reimplantation. However, this conduct does not always work favorably, either by failures in the initial approach or by inappropriate interventions. In this sense, the aim of this study is to present an alternative prosthetic rehabilitation with the use of orthodontic mini-implants in the anterior region. This case reports a ten-year-old child with history of avulsion of superior central incisors. The therapeutic approach was planned to promote physiological teeth contacts and acceptable esthetics and phonetics. First, the occlusal-gingival insertion of two orthodontic mini-implants was performed in the alveolar ridge, and, immediately after that, two provisional crowns were attached to the implants. The interventions achieved satisfactory cosmetic and functional results. After one-year follow-up, the adjacent periodontal tissues remained without signs and/or symptoms of inflammation. The provisional crowns presented no mobility and fractures. During radiographic examination, a healthy bone tissue appearance was observed. The simplicity of mini-implant installation makes them a promising alternative for temporary prosthetic rehabilitation of patients undergoing growth and development. The technique provides positive aesthetic and functional results that may reflect on self-esteem and social inclusion of children and adolescents.

  15. Injuries in Japanese Mini-Basketball Players During Practices and Games

    Science.gov (United States)

    Kuzuhara, Kenji; Shibata, Masashi; Uchida, Ryo

    2016-01-01

    Context: Mini-basketball is one of the most popular junior sports in Japan. Mini-basketball–related injuries may increase because of early specialization. However, no reports have been published to date concerning basketball injuries in children younger than 12 years of age. Objective: To prospectively study the incidence, sites, types, and mechanisms of injuries in mini-basketball teams. Design: Descriptive epidemiology study. Setting: Mini-basketball teams in Kobe, Japan. Patients or Other Participants: A total of 95 players in 7 community-based mini-basketball club teams (age range, 9 through 12 years). Main Outcome Measure(s): Data on all practice and game injuries for the 2013–2014 season were collected using an injury report form. Injury rates were calculated according to site, type, and mechanism. Results: The overall injury rate was 3.83 per 1000 athlete-hours (AHs). The game injury rate (12.92/1000 AHs) was higher than the practice injury rate (3.13/1000 AHs; P basketball players. The high practice injury rate in this study may be due to specific factors related to growth, such as individual differences in height, or to skills, such as inexperience in ball handling. PMID:27922287

  16. Gender and Self-Employment: The Role of Mini-Companies

    Science.gov (United States)

    Johansen, Vegard

    2016-01-01

    Purpose: The purpose of this paper is to evaluate to what degree participation in mini-companies impact young women and men with regard to the perceived desirability and perceived feasibility of self-employment. The Company Programme (CP) is the largest mini-company scheme in European secondary school. Design/methodology/approach: The data derived…

  17. Afrique : ressources minières, environnement et gouvernance ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    25 janv. 2011 ... ils regorgent de richesses inouïes », assure Bonnie Campbell, directrice du Groupe de recherche sur les activités minières en Afrique (GRAMA) et titulaire de la Chaire C.-A. Poissant de recherche sur la gouvernance et l'aide au développement, faisant référence aux ressources minières et pétrolières dont ...

  18. MiniDLNA_tweaker : Aplicació per configurar i previsualitzar el servidor MiniDLNA per a GNU/Linux

    OpenAIRE

    Martínez Lloveras, Jordi

    2013-01-01

    L'aplicació MiniDLNA per a GNU/Linux és un servidor lleuger que compleix els estàndards DLNA/UPnP configurable a través d'un simple arxiu de text, això la fa ideal per al propòsit d'implantació d'un servidor que ofereixi els continguts a tots els dispositius que compleixin els estàndards esmentats. La aplicación MiniDLNA para GNU/Linux es un servidor ligero que cumple los estándares DLNA/UPnP configurable a través de un simple archivo de texto, esto la hace ideal para el propósito de impla...

  19. Technology of forming a positive attitude to physical training students of special medical group

    Directory of Open Access Journals (Sweden)

    Mukhamediarov N.N.

    2013-04-01

    Full Text Available Defined effective technology stages of forming a positive attitude towards physical education of students in special medical groups, stimulate motivation, epistemologically, informative, content-procedural, analytical and adjustment. For each stage technology offered special tools: lectures, seminars, analysis articles, mini conference on improving technique, racing games, mini-competitions, diagnostic interviews, questionnaires, analysis of log data on attendance. Selected criteria forming positive attitudes towards physical education: theoretical and practical, formed groups for research: experimental and control, analyzed results introduction of technology, efficiency of the proposed technology and means forming a positive attitude towards physical education students in special medical groups.

  20. Agreement between clinical and MINI diagnoses in outpatients with mood and anxiety disorders

    NARCIS (Netherlands)

    Verhoeven, F. E. A.; Swaab, L. S. M. A.; Carlier, I. V. E.; van Hemert, A. M.; Zitman, F. G.; Ruhé, H. G.; Schoevers, R. A.; Giltay, E. J.

    2017-01-01

    Background: Standardized Diagnostic Interviews (SDIs) such as the Mini International Neuropsychiatric Interview (MINI) are widely used to systematically screen for psychiatric disorders in research. To support generalizability of results to clinical practice, we assessed agreement between the MINI

  1. Accuracy of Korean-Mini-Mental Status Examination Based on Seoul Neuro-Psychological Screening Battery II Results.

    Science.gov (United States)

    Kang, In-Woong; Beom, In-Gyu; Cho, Ji-Yeon; Son, Hyo-Rim

    2016-05-01

    The Korean-Mini-Mental Status Examination (K-MMSE) is a dementia-screening test that can be easily applied in both community and clinical settings. However, in 20% to 30% of cases, the K-MMSE produces a false negative response. This suggests that it is necessary to evaluate the accuracy of K-MMSE as a screening test for dementia, which can be achieved through comparison of K-MMSE and Seoul Neuropsychological Screening Battery (SNSB)-II results. The study included 713 subjects (male 534, female 179; mean age, 69.3±6.9 years). All subjects were assessed using K-MMSE and SNSB-II tests, the results of which were divided into normal and abnormal in 15 percentile standards. The sensitivity of the K-MMSE was 48.7%, with a specificity of 89.9%. The incidence of false positive and negative results totaled 10.1% and 51.2%, respectively. In addition, the positive predictive value of the K-MMSE was 87.1%, while the negative predictive value was 55.6%. The false-negative group showed cognitive impairments in regions of memory and executive function. Subsequently, in the false-positive group, subjects demonstrated reduced performance in memory recall, time orientation, attention, and calculation of K-MMSE items. The results obtained in the study suggest that cognitive function might still be impaired even if an individual obtained a normal score on the K-MMSE. If the K-MMSE is combined with tests of memory or executive function, the accuracy of dementia diagnosis could be greatly improved.

  2. Do dual-thread orthodontic mini-implants improve bone/tissue mechanical retention?

    Science.gov (United States)

    Lin, Yang-Sung; Chang, Yau-Zen; Yu, Jian-Hong; Lin, Chun-Li

    2014-12-01

    The aim of this study was to understand whether the pitch relationship between micro and macro thread designs with a parametrical relationship in a dual-thread mini-implant can improve primary stability. Three types of mini-implants consisting of single-thread (ST) (0.75 mm pitch in whole length), dual-thread A (DTA) with double-start 0.375 mm pitch, and dual-thread B (DTB) with single-start 0.2 mm pitch in upper 2-mm micro thread region for performing insertion and pull-out testing. Histomorphometric analysis was performed in these specimens in evaluating peri-implant bone defects using a non-contact vision measuring system. The maximum inserted torque (Tmax) in type DTA was found to be the smallest significantly, but corresponding values found no significant difference between ST and DTB. The largest pull-out strength (Fmax) in the DTA mini-implant was found significantly greater than that for the ST mini-implant regardless of implant insertion orientation. Mini-implant engaged the cortical bone well as observed in ST and DTA types. Dual-thread mini-implant with correct micro thread pitch (parametrical relationship with macro thread pitch) in the cortical bone region can improve primary stability and enhanced mechanical retention.

  3. Photovoltaic energy mini-generation: Future perspectives for Portugal

    International Nuclear Information System (INIS)

    Carvalho, Duarte; Wemans, Joao; Lima, Joao; Malico, Isabel

    2011-01-01

    This paper evaluates the benefits of developing the mini-generation PV market in Portugal. It presents the legal framework and current status of the Portuguese PV electricity sector, and compares the country to other European nations: France, Germany, Greece, Italy, Spain and the United Kingdom. A model that combines PVGIS with a self-developed financial tool is used to assess the feasibility of a 150 kW mini-generation system using five different technologies: fixed mount, single-axis tracking, double-axis tracking, low concentration and medium concentration (MCPV). The profitability of the mini-generation systems in the seven countries studied is calculated and compared. According to this analysis, MCPV and, of the conventional technologies, the single-axis tracking systems are the most profitable technologies. Despite the attractiveness of the current Portuguese feed-in tariffs and of the abundant solar resource, investors are discouraged and the country's PV market is far from mature. Specific mini-generation regulations should focus on a fast and transparent licensing procedure and should promote the access to financing. This would attract new investments, which would result in the growth of the PV electricity produced, and would help Portugal to meet its European Union Renewable Energy targets. - Highlights: → This work promotes the development of a mini-generation PV market in Portugal. → The Portuguese current status and legal framework is compared to other EU countries. → The profitability of 5 different PV technologies is compared for 7 European countries. → The Portuguese growth potential for PV energy is still big. → Portugal, due to its radiation levels, presents excellent investment opportunities.

  4. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA in a Mexican Population

    Directory of Open Access Journals (Sweden)

    María Fernanda Bernal-Orozco

    2018-04-01

    Full Text Available Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy or 1 (healthy, and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016, were invited to participate. The survey was administered in two rounds (test and retest with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC, and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant. The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001, and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885. It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  5. Paradigm shifts in orthodontic treatment with mini-implant anchorage

    Directory of Open Access Journals (Sweden)

    Johnny Joung-Lin Liaw

    2015-01-01

    Full Text Available After the applications of mini-implant anchorage, the envelope of orthodontic treatment was expanded and some treatment modes were changed because of more predictable tooth movement with empowered anchorage. The author tried to share his experience of TADs applications for clarifying the paradigm shifts of orthodontic treatment assisted with the mini-implant anchorage.

  6. Mini implants for definitive prosthodontic treatment: a systematic review.

    Science.gov (United States)

    Bidra, Avinash S; Almas, Khalid

    2013-03-01

    Mini implants are commonly used in orthodontics and for interim prosthodontic treatment, but evidence for their use in definitive prosthodontic treatment is not clear. This systematic review evaluated the mini-implant literature to analyze short-term (1 to 5 years), medium-term (5 to 10 years), and long-term (beyond 10 years) survival rates when used for definitive prosthodontic treatment. An electronic search of the English language literature for articles published between January 1974 and May 2012 was performed by using PubMed and Cochrane databases with predetermined inclusion criteria. Key terms included in the search were mini dental implants, narrow diameter implants, reduced diameter implants, small diameter implants, transitional implants, interim implants, and provisional implants. After a systematic filtering process, the selected articles were subjected to a detailed review, and the data collected were used to calculate the 1-year interval survival rate (ISR) and the cumulative survival rate (CSR). The electronic database search yielded 1807 titles. By scrutinizing the titles and abstracts with inclusion and exclusion criteria, the researchers identified 9 studies of mini implants for definitive prosthodontic treatment. Of the studies identified, 1 was a randomized controlled trial, 2 were prospective studies, and 6 were retrospective studies. The majority of mini implants were placed by using a flapless surgical technique in the mandibular anterior region to support an overdenture. The 1st year ISR was 94.7% and the CSR over a 9-year period, primarily attributed to data from 1 study, was 92.2%. Most implants were immediately loaded and almost all implant failures occurred during the first year after implant placement. For short-term survival, the first year ISR of 94.7% of mini dental implants appears encouraging, but the true 1-year survival rate is unknown, as the minimum follow-up period reported for several implants was less than a year

  7. Mini-Sniffer III on Lakebed with Ground Support Crew

    Science.gov (United States)

    1976-01-01

    The third version of the Mini-Sniffer remotely-piloted research vehicle on Rogers Dry Lake, adjacent to NASA's Dryden Flight Research Center, Edwards, California. The futuristic-looking ground crew are in white, self-contained suits, because the engine on this third version of the Mini-Sniffer was powered by hydrazine, which is a very hazardous material. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the

  8. Importance of accurate diagnosis in benign paroxysmal positional vertigo (BPPV) therapy.

    Science.gov (United States)

    Maslovara, Siniša; Vešligaj, Tihana; Butković Soldo, Silva; Pajić-Penavić, Ivana; Maslovara, Karmela; Mirošević Zubonja, Tea; Soldo, Anamarija

    2014-08-01

    To determine the importance of accurate topological diagnostics of the otolith and the differentiation of certain clinical forms of benign paroxysmal positional vertigo (BPPV). A prospective study was conducted at the County General Hospital Vukovar in the period from January 2011 till January 2012. A total of 81 patients with BPPV, 59 females (72.84%) and 22 (27.16%) males (p less than 0.001), mean age 60.1 (± 12.1) were examined. The diagnosis was confirmed and documented by videonystagmography (VNG). The disability due to disease and risk of falling were monitored by filling in the Dizziness Handicap Inventory (DHI) and Activities-specific Balance Confidence Scale (ABC) questionnaires at the beginning and at the end of the repositioning treatment. In 79 (97.3%) patients posterior semicircular canal was affected, and in a small number of patients, two (2.47%) the lateral one. After the repositioning procedures were performed, there was a significant reduction or complete elimination of symptoms in the majority of subjects, 76 (93.82%). The median total DHI sum amounted to 50.5 (± 22.2) at the beginning and 20.4 (± 18.5) at the end of the study (p less than 0.00). Similarly, the results of ABC questionnaires at the beginning of the study demonstrated a result of 59.2% (± 22.4%), and at the end of the treatment the average result of examinees was significantly higher, 84.9% (± 15.2%) (p less than 0.00). Although a subjectively positive Dix-Hallpike or a "supine roll" test is sufficient for the diagnosis of BPPV, it is necessary perform the VNG as well in order to precisely determine the exact localization of the otolith, so that an appropriate repositioning procedure can be applied.

  9. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Science.gov (United States)

    Perevalov, Denis

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for numu → nu e neutrino oscillations at Deltam 2 ˜ 1 eV2 using an intense neutrino flux with an average energy Enu ˜ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0x1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semi-inclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current pi 0, charged current quasi-elastic (CCQE), charged current pi +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (nuN → nu N) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Deltas, this however requires a separation of NCE proton (nup → nu p) from NCE neutron (nun → nun ) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Deltas measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement

  10. Recommended safety objectives, principles and requirements for mini-reactors

    International Nuclear Information System (INIS)

    1991-05-01

    Canadian and international publications containing objectives, principles and requirements for the safety of nuclear facilities in general and nuclear power plants in particular have been reviewed for their relevance to mini-reactors. Most of the individual recommendations, sometimes with minor wording changes, are applicable to mini-reactors. However, some prescriptive requirements for the shutdown, emergency core cooling and containment systems of power reactors are considered inappropriate for mini-reactors. The Advisory Committee on Nuclear Safety favours a generally non-prescriptive approach whereby the applicant for a mini-reactor license is free to propose any means of satisfying the fundamental objectives, but must convince the regulatory agency to that effect. To do so, a probabilistic safety assessment (PSA) would be the favoured procedure. A generic PSA for all mini-reactors of the same design would be acceptable. Notwithstanding this non-prescriptive approach, the ACNS considers that it would be prudent to require the existence of at least one independent shutdown system and two physically independent locations from which the reactor can be shut down and the shutdown condition monitored, and to require provision for an assumed loss of integrity of the primary cooling system's boundary unless convincing arguments to the contrary are presented. The ACNS endorses in general the objectives and fundamental principles proposed by the interorganizational Small Reactor Criteria working group, and intends to review and comment on the documents on specific applications to be issued by that working group

  11. Cryopreservation of boar semen in mini- and maxi-straws.

    Science.gov (United States)

    Bwanga, C O; de Braganca, M M; Einarsson, S; Rodriguez-Martinez, H

    1990-10-01

    Split ejaculates from four boars were frozen with a programmable freezing machine, in mini- (0.25 ml) and maxi- (5 ml) plastic straws with an extender at either acidic (6.3) or alkaline (7.4) pH. Glycerol (3%) was used as cryoprotectant. The freezing of the semen was monitored by way of thermocouples placed in the straws. Post-thaw motility and acrosome integrity were evaluated; the latter using phase contrast microscopy, eosin-nigrosin stain and electron microscopy. Post-thaw sperm motility was significantly higher when semen was frozen in mini-straws than in maxi-straws. For the mini-straws, the motility was better when semen was exposed to an acidic environment during freezing, but this beneficial effect of the low extracellular pH was not evident when maxi-straws were thawed. The motility of the spermatozoa diminished significantly during the thermoresistance test (0 h and 2 h time) at 37 degrees C in a similar way for both straws and extracellular pH's. The freezing procedure, no matter the extracellular pH, did not cause major acrosomal damages, but significantly more normal apical ridges were present in the mini-straws than in the maxi-straws. This in vitro evaluation indicated that the freezing method employed was better for mini- than for maxi-straws since the freezing of the 5 ml volumes was not homogeneous, due to the large section area between the surface and the core of the straw.

  12. A mini-microscope for in situ monitoring of cells†‡

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R.; Hamilton, Geraldine A.; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E.

    2013-01-01

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost. PMID:22911426

  13. Impact of Mini-drone based Video Surveillance on Invasion of Privacy

    OpenAIRE

    Korshunov, Pavel; Bonetto, Margherita; Ebrahimi, Touradj; Ramponi, Giovanni

    2015-01-01

    An increase in adoption of video surveillance, affecting many aspects of daily lives, raises public concern about an intrusion into individual privacy. New sensing and surveillance technologies, such as mini-drones, threaten to eradicate boundaries of private space even more. Therefore, it is important to study the effect of mini-drones on privacy intrusion and to understand how existing protection privacy filters perform on a video captured by a mini-drone. To this end, we have built a publi...

  14. NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2016-03-01

    Full Text Available Abstract NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE. Research of UMo fuel for research reactor has been developing  right now. The fuel of  research reactor used is uranium low enrichment with high density. For supporting the development of fuel, an assessment of mini fuel in the RSG-GAS core was performed. The mini fuel are U7Mo-Al and U6Zr-Al with densitis of 7.0gU/cc and 5.2 gU/cc, respectively. The size of both fuel are the same namely 630x70.75x1.30 mm were inserted to the 3 plates of dummy fuel. Before being irradiated in the core, a calculation for safety analysis  from neutronics and thermohydrolics aspects were required. However, in this paper will discuss safety analysis of the U7Mo-Al and U6Zr-Al mini fuels from neutronic point of view.  The calculation was done using WIMSD-5B and Batan-3DIFF code. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. Power density of U7Mo-Al mini fuel bigger than U6Zr-Al fuel.   Key words: mini fuel, neutronics analysis, reactor core, safety analysis   Abstrak ANALISIS NEUTRONIK ELEMEN BAKAR UJI MINI DI TERAS RSG-GAS. Penelitian tentang bahan bakar UMo untuk reaktor riset terus berkembang saat ini. Bahan bakar reaktor riset yang digunakan adalah uranium pengkayaan rendah namun densitas tinggi.  Untuk mendukung pengembangan bahan bakar dilakukan uji elemen bakar mini di teras reakror RSG-GAS dengan tujuan menentukan jumlah siklus di dalam teras sehingga tercapai fraksi bakar maksimum. Bahan bakar yang diuji adalah U7Mo-Al dengan densitas 7,0 gU/cc dan U6Zr-Al densitas 5,2 gU/cc. Ukuran kedua bahan bakar uji tersebut adalah sama 630x70,75x1,30 mm dimasukkan masing masing kedalam 3 pelat dummy bahan bakar. Sebelum diiradiasi ke dalam teras reaktor maka perlu dilakukan perhitungan keselamatan baik secara neutronik maupun termohidrolik. Dalam makalah ini

  15. A DNA Mini-Barcoding System for Authentication of Processed Fish Products.

    Science.gov (United States)

    Shokralla, Shadi; Hellberg, Rosalee S; Handy, Sara M; King, Ian; Hajibabaei, Mehrdad

    2015-10-30

    Species substitution is a form of seafood fraud for the purpose of economic gain. DNA barcoding utilizes species-specific DNA sequence information for specimen identification. Previous work has established the usability of short DNA sequences-mini-barcodes-for identification of specimens harboring degraded DNA. This study aims at establishing a DNA mini-barcoding system for all fish species commonly used in processed fish products in North America. Six mini-barcode primer pairs targeting short (127-314 bp) fragments of the cytochrome c oxidase I (CO1) DNA barcode region were developed by examining over 8,000 DNA barcodes from species in the U.S. Food and Drug Administration (FDA) Seafood List. The mini-barcode primer pairs were then tested against 44 processed fish products representing a range of species and product types. Of the 44 products, 41 (93.2%) could be identified at the species or genus level. The greatest mini-barcoding success rate found with an individual primer pair was 88.6% compared to 20.5% success rate achieved by the full-length DNA barcode primers. Overall, this study presents a mini-barcoding system that can be used to identify a wide range of fish species in commercial products and may be utilized in high throughput DNA sequencing for authentication of heavily processed fish products.

  16. Mini mental state examination

    DEFF Research Database (Denmark)

    Kørner, Ejnar Alex; Lauritzen, Lise; Wang, August

    2008-01-01

    INTRODUCTION: The Mini Mental State Examination (MMSE) is widely used in Denmark, but often in non-validated versions. In 2000 a cross-sectional workgroup decided on a new common version of the MMSE with a corresponding manual, which is validated for the first time in the present study. MATERIALS...... the severity of dementia disorders. Udgivelsesdato: 2008-Feb-25...

  17. Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach

    Directory of Open Access Journals (Sweden)

    A. Sumathi Felicita

    Full Text Available ABSTRACT Objective: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. Methods: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. Results: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5o to 16o from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. Conclusion: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios.

  18. Implementing the undergraduate mini-CEX: a tailored approach at Southampton University.

    Science.gov (United States)

    Hill, Faith; Kendall, Kathleen; Galbraith, Kevin; Crossley, Jim

    2009-04-01

    The mini-clinical evaluation exercise (mini-CEX) is widely used in the UK to assess clinical competence, but there is little evidence regarding its implementation in the undergraduate setting. This study aimed to estimate the validity and reliability of the undergraduate mini-CEX and discuss the challenges involved in its implementation. A total of 3499 mini-CEX forms were completed. Validity was assessed by estimating associations between mini-CEX score and a number of external variables, examining the internal structure of the instrument, checking competency domain response rates and profiles against expectations, and by qualitative evaluation of stakeholder interviews. Reliability was evaluated by overall reliability coefficient (R), estimation of the standard error of measurement (SEM), and from stakeholders' perceptions. Variance component analysis examined the contribution of relevant factors to students' scores. Validity was threatened by various confounding variables, including: examiner status; case complexity; attachment specialty; patient gender, and case focus. Factor analysis suggested that competency domains reflect a single latent variable. Maximum reliability can be achieved by aggregating scores over 15 encounters (R = 0.73; 95% confidence interval [CI] +/- 0.28 based on a 6-point assessment scale). Examiner stringency contributed 29% of score variation and student attachment aptitude 13%. Stakeholder interviews revealed staff development needs but the majority perceived the mini-CEX as more reliable and valid than the previous long case. The mini-CEX has good overall utility for assessing aspects of the clinical encounter in an undergraduate setting. Strengths include fidelity, wide sampling, perceived validity, and formative observation and feedback. Reliability is limited by variable examiner stringency, and validity by confounding variables, but these should be viewed within the context of overall assessment strategies.

  19. A high-resolution mini-microscope system for wireless real-time monitoring.

    Science.gov (United States)

    Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung

    2017-09-04

    Compact, cost-effective and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless mini-microscope with resolution up to 2592 × 1944 pixels and speed up to 90 fps. The mini-microscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed mini-microscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 hours. In addition, the mini-microscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the mini-microscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed mini-microscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high resolution mini-microscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.

  20. PARTICIPATION OF MINI-BASKETBALL PLAYERS DURING SMALL-SIDED COMPETITIONS

    Directory of Open Access Journals (Sweden)

    M\\u00AA Isabel Pi\\u00F1ar

    2009-01-01

    Full Text Available This study presents the differences of competition between mini-basketball with the traditional rules (5-a-side and minibasket with rule modifications (3-a-side such as: reduced number of players on court, compulsory participation in 2 of the match's 4 periods, reduced court size, placing the free throw line at 3m from the basket, and including a three-point line. The sample that was selected included 47 mini-basketball players, and the study was carried out using a quasi-experimental design without a control group. The aim was to determine the effect of rule modifications on the participation of the player with the ball. It was demonstrated that the degree of individual participation is greater in mini-basketball with modified rules.

  1. Two mini-preparation protocols to DNA extraction from plants with ...

    African Journals Online (AJOL)

    Were standardized two previously reported standard plant DNA extraction methods, but improved them on mini preparations to use the samples for population genetic analysis. The combination of CTAB lysis procedure-solvent extraction and DNA column purification (DNeasy plant mini kit modification) enables a faster and ...

  2. High-flying Mini-Sniffer RPV - Mars bound

    Science.gov (United States)

    Reed, R. D.

    1978-01-01

    The Mini-Sniffer is a small unmanned survey aircraft developed by NASA to conduct turbulence and atmospheric pollution measurements from ground level to an altitude of 90,000 ft. Carrying a 25-lb air sampling apparatus, the Mini-Sniffer typically cruises for one hour at 70,000 ft before being remotely piloted back to earth. A hydrazine monopropellant engine powers the craft, while a PCM telemetering system and a radar transponder provide control functions. Development of a high-performance low-Reynolds-number airfoil could make the research craft suitable for a low-altitude terrain-following mission on Mars.

  3. GeMini: The Next Generation Mechanically-Cooled Germanium Spectrometer

    International Nuclear Information System (INIS)

    Burks, M.

    2008-01-01

    The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (GErmanium MINIature spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice and surprise inspections where positive nuclide identification of radioactive materials is required. GeMini weighs 2.75 kg (6 lbs) total including the detector, cryostat, cryocooler, batteries, electronics and readout. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Two working prototypes have been built and tested in the lab. The target energy resolution is 3 keV fwhm or better for 1332 keV gamma-rays. The detectors currently achieve around 4.5 keV resolution, which is slightly higher than our goal due to microphonic noise. Our present work focuses on improving the resolution through mechanical and electronic means of reducing the microphonic noise. This paper will focus on the performance of the instrument and its applicability for inspectors in the field

  4. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC) among a heterogeneous sample of long-term cancer survivors: a cross-sectional study.

    Science.gov (United States)

    Zucca, Alison; Lambert, Sylvie D; Boyes, Allison W; Pallant, Julie F

    2012-05-20

    The mini-Mental Adjustment to Cancer Scale (mini-MAC) is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. RUMM 2030 was used to analyse the mini-MAC data (n=851). Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI), response format, local dependency, targeting, item bias (or differential item functioning -DIF), and dimensionality. For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales - Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of adaptive and maladaptive coping, extensive modifications were

  5. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC among a heterogeneous sample of long-term cancer survivors: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Zucca Alison

    2012-05-01

    Full Text Available Abstract Background The mini-Mental Adjustment to Cancer Scale (mini-MAC is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. Methods RUMM 2030 was used to analyse the mini-MAC data (n=851. Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI, response format, local dependency, targeting, item bias (or differential item functioning -DIF, and dimensionality. Results For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales – Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. Conclusions The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of

  6. Psychometric evaluation of a Dutch version of the Mini PAS-ADD for assessing psychiatric disorders in adults with different levels of intellectual disability

    OpenAIRE

    Janssen, Rianne; Maes, Bea

    2013-01-01

    Background People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. Method A Dutch version of the Mini PAS-ADD, which is a screening instrument for identification of mental health problems in people with ID, was evaluated in terms of internal consistency, interinformant reliability, item grouping and ...

  7. A preliminary study of the mini-mental state examination in a Spanish child population.

    Science.gov (United States)

    Rubial-Alvarez, Sandra; Machado, María-Clara; Sintas, Elena; de Sola, Susana; Böhm, Peter; Peña-Casanova, Jordi

    2007-11-01

    The Mini-Mental State Examination is one of the most widely used screening tests for the adult population in daily neurologic practice. The aim of this study was to describe and to analyze the results of the Mini-Mental State Examination administered to Spanish children and to assess the relationship between Mini-Mental State Examination scores and the child's mental age/intelligence quotient. The study population included 181 children whose ages ranged between 4 and 12 years. The neuropsychologic battery consisted of the Mini-Mental State Examination and Kaufman Brief Intelligence Test. Percentiles were obtained for the Mini-Mental State Examination total score according to age ranges. Performance gradually increased from 4 to 10 years of age when a plateau in the total Mini-Mental State Examination score was reached. At the age of 6 years, results exceeded 24 on average. Pairwise mean comparisons showed statistically significant differences between the age groups (P Mini-Mental State Examination score correlated significantly with the child's chronologic (r = 0.80, P mental (r = 0.76, P Mini-Mental State Examination in a Spanish child population as well as a first step for the assessment of the usefulness of this instrument as a cognitive screening tool for children's development.

  8. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  9. Presence of dual diagnosis between users and non-users of licit and illicit drugs in Brazil

    Directory of Open Access Journals (Sweden)

    Mariana Bandeira Formiga

    2015-12-01

    Full Text Available ABSTRACT Objective Investigate the occurrence of dual diagnosis in users of legal and illegal drugs. Methods It is an analytical, cross-sectional study with a quantitative approach, non-probabilistic intentional sampling, carried out in two centers for drug addiction treatment, by means of individual interviews. A sociodemographic questionnaire, the Alcohol, Smoking and Substance Involvement Screening Test (ASSIST and the Mini-International Neuropsychiatric Interview (MINI were used. Results One hundred and ten volunteers divided into abstinent users (group 1, alcoholics (group 2 and users of alcohol and illicit drugs (group 3. The substances were alcohol, tobacco, crack and marijuana. A higher presence of dual diagnosis in group 3 (71.8% was observed, which decreased in group 2 (60% and 37.1% of drug abstinent users had psychiatric disorder. Dual diagnosis was associated with the risk of suicide, suicide attempts and the practice of infractions. The crack consumption was associated with the occurrence of major depressive episode and antisocial personality disorder. Conclusion It was concluded that the illicit drug users had a higher presence of dual diagnosis showing the severity of this clinical condition. It is considered essential that this clinical reality is included in intervention strategies in order to decrease the negative effects of consumption of these substances and provide better quality of life for these people.

  10. Mini-stop bands in single heterojunction photonic crystal waveguides

    KAUST Repository

    Shahid, N.; Amin, M.; Naureen, S.; Anand, S.

    2013-01-01

    Spectral characteristics of mini-stop bands (MSB) in line-defect photonic crystal (PhC) waveguides and in heterostructure PhC waveguides having one abrupt interface are investigated. Tunability of the MSB position by air-fill factor heterostructure PhC waveguides is utilized to demonstrate different filter functions, at optical communication wavelengths, ranging from resonance-like to wide band pass filters with high transmission. The narrowest filter realized has a resonance-like transmission peak with a full width at half maximum of 3.4 nm. These devices could be attractive for coarse wavelength selection (pass and drop) and for sensing applications. 2013 Copyright 2013 Author(s). This article is distributed under a Creative Commons Attribution 3.0 Unported License.

  11. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Perevalov, Denis [Univ. of Alabama, Tuscaloosa, AL (United States)

    2009-12-01

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for vμ → ve neutrino oscillations at Δm2 ~ 1 eV2 using an intense neutrino flux with an average energy Ev ~ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0 x 1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semiinclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current π0, charged current quasi-elastic (CCQE), charged current π+, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (vN → vN) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Δs, this however requires a separation of NCE proton (vp → vp) from NCE neutron (vn → vn) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Δs measurement. In this thesis

  12. Review of Strategies and Technologies for Demand-Side Management on Isolated Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Harper, Meg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-03-01

    This review provides an overview of strategies and currently available technologies used for demandside management (DSM) on mini-grids throughout the world. For the purposes of this review, mini-grids are defined as village-scale electricity distribution systems powered by small local generation sources and not connected to a main grid.1 Mini-grids range in size from less than 1 kW to several hundred kW of installed generation capacity and may utilize different generation technologies, such as micro-hydro, biomass gasification, solar, wind, diesel generators, or a hybrid combination of any of these. This review will primarily refer to AC mini-grids, though much of the discussion could apply to DC grids as well. Many mini-grids include energy storage, though some rely solely on real-time generation.

  13. Detection and eradication of Spongospora subterranea in mini-tuber production tunnels

    Directory of Open Access Journals (Sweden)

    Jacquie E. van der Waals

    2012-05-01

    Full Text Available Powdery scab, a root and tuber disease caused by the pathogen Spongospora subterranea f.sp. subterranea (Sss, poses a major problem to potato producers worldwide because it affects potato quality. Inoculum can be seed-borne or originate from contaminated growing media or contaminated equipment. During 2006, a potato mini-tuber production facility in Ceres in the Western Cape Province of South Africa had an outbreak of powdery scab. The purpose of this study was to detect Sss in the production facility and identify the source or sources of contamination so that corrective measures could be taken to eradicate the pathogen. Swab samples were taken from numerous points in the facility in 2009 and Sss-specific primers (Sps1 and Sps2 were used in a polymerase chain reaction to detect Sss. Of 11 surfaces tested, 6 were positive for Sss. A second set of swab samples was taken after efforts were made to eradicate the pathogen through improved facility hygiene measures to determine whether these corrective measures were efficient. Corrective measures resulted in a disease-free harvest from 2009 onwards. This novel study has value for the mini-tuber industry as production tunnels can be tested for the presence of Sss and other pathogens before planting to ensure that, where suitable control measures are available, disease-free mini-tubers are produced.

  14. Pengaruh Permaianan Bola Voli Mini Terhadap Peningkatan Kebugaran Jasmani Pecandu Narkoba

    Directory of Open Access Journals (Sweden)

    Kurnia Rismaningtyas

    2016-10-01

    Full Text Available This study aims to answer the following questions: 1 the influence of a volleyball mini-game model to increase physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. 2 How big contribution volleyball mini model of the game due to the improvement of physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. . T test results obtained tcount for data post test of 2,420 with significance 0.022 <0.05, which means that the average physical fitness between the experimental and control groups after treatment was significantly different. Judging from an average of 35.79 in the experimental group and the control group of 32.92 indicates that the level of physical fitness of women prisoners IIA class drug addict treatment Semarang made a game of volleyball mini-game is better than that do not follow the game of volleyball mini , In the experimental group increased physical fitness significantly, evident from the value t = 6.541 with a significance value of 0.000 <0.05. It was concluded that: 1 Model mini volleyball games that do can improve the physical fitness of inmates in prisons Women Class II A Semarang. 2 In the experimental group showed that the model of a volleyball mini-game has a significant influence on the improvement of physical fitness on female inmates in prison Women drug addicts Class II A Semarang.

  15. Mini-guide til DGNB

    DEFF Research Database (Denmark)

    Larsen, Tine Steen

    Guiden giver et kort indblik i formålet med de enkelte kriterier i en DGNB- bæredygtighedsvurdering, samt i hvordan der kan måles på kriterierne. Mini-guiden tager afsæt i systemet for certificering af Nybyggede kontor-og erhvervsbyggerier, som er det første og grundlæggende system i DGNB, som al...

  16. Horizontal canal benign paroxysmal positional vertigo: diagnosis and treatment of 37 patients

    Directory of Open Access Journals (Sweden)

    Eliana Teixeira Maranhão

    2015-06-01

    Full Text Available Benign paroxysmal positional vertigo (BPPV, the most frequent cause of vertigo is associated with high morbidity in the elderly population. The most common form is linked to debris in the posterior semicircular canal. However, there has been an increasing number of reported BPPV cases involving the horizontal canals. The purpose of this article is to highlight the clinical features, diagnosis, and treatment in 37 patients with horizontal canal BPPV; twenty-six with geotropic nystagmus, and eleven with the apogeotropic form. Treatment consisted of the Gufoni manoeuver in eighteen patients (48.6%, the barbecue 360° maneuver in twelve patients (32.4%, both manoeuvers in four patients (10.8%, both manoeuvers plus head shaking in one patient (2.7%, and the Gufoni maneuver plus head shaking in two patients. Cupulolithiasis patients were asked to sleep in a forced prolonged position. We obtained a complete resolution of vertigo and nystagmus in 30 patients (81.0% on the initial visit.

  17. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics

    Directory of Open Access Journals (Sweden)

    El-Say Khalid M.

    2015-12-01

    Full Text Available This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1, swelling pressure of the superdisintegrant (X2, and the surface area of Aerosil as a glidant (X3. Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for preand post-compression characteristics. The prepared ODmini- tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2 and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  18. Entrepreneur and Establishment of a Mini Hotel in XiChang, China

    OpenAIRE

    Hu, Mingsong

    2013-01-01

    Mini Hotel, is a new hotel will be opened in China in this year. I and 4 of my friends will be the shareholders of this Mini Hotel. The hotel is planned to be operating from the autumn of 2013. Now, everything in this thesis is on process. The main objective of this thesis was to draft an effective approach to ensure this is a right plan which is worth to invest. By using benchmarking and SWOT analysis we defined the strength and weakness of this Mini Hotel business plan. This thesis will ...

  19. Model of competitive mini-hotel project life cycle

    OpenAIRE

    Левыкин, Виктор Макарович; Дэвон, Валерия Викторовна

    2014-01-01

    Having examined the situation in the hotel market of the city of Kharkov (Ukraine), it was found that one of the major shortcomings in the activities of mini-hotels is mediocre attitude towards customers, lack of proper attention and poor services. In this regard, there is the need to create a mini-hotel, the most important mission of which would be a genuine concern for guests and their comfort, as well as providing unique services of the highest class.For the success of this mission, it is ...

  20. Lexicography Problems and Theoretical Interpretation of Mini-Dictionaries

    Directory of Open Access Journals (Sweden)

    Jūratė Butkienė

    2011-04-01

    Full Text Available The article deals with principles of the word selection while compiling a mini-dictionary (containing a minimal number of words as well as with criteria and theoretical background thereof. The development of such principles is being analysed in Lithuania and abroad. The word selection while compiling a mini-dictionary of German language dedicated to the students of Civil engineering is being detailed. Furthermore, the article provides recommendations. The word selection has to be based on the linguistic statistics and on the thorough text analysis.

  1. Feasibility of a multiple-choice mini mental state examination for chronically critically ill patients.

    Science.gov (United States)

    Miguélez, Marta; Merlani, Paolo; Gigon, Fabienne; Verdon, Mélanie; Annoni, Jean-Marie; Ricou, Bara

    2014-08-01

    Following treatment in an ICU, up to 70% of chronically critically ill patients present neurocognitive impairment that can have negative effects on their quality of life, daily activities, and return to work. The Mini Mental State Examination is a simple, widely used tool for neurocognitive assessment. Although of interest when evaluating ICU patients, the current version is restricted to patients who are able to speak. This study aimed to evaluate the feasibility of a visual, multiple-choice Mini Mental State Examination for ICU patients who are unable to speak. The multiple-choice Mini Mental State Examination and the standard Mini Mental State Examination were compared across three different speaking populations. The interrater and intrarater reliabilities of the multiple-choice Mini Mental State Examination were tested on both intubated and tracheostomized ICU patients. Mixed 36-bed ICU and neuropsychology department in a university hospital. Twenty-six healthy volunteers, 20 neurological patients, 46 ICU patients able to speak, and 30 intubated or tracheostomized ICU patients. None. Multiple-choice Mini Mental State Examination results correlated satisfactorily with standard Mini Mental State Examination results in all three speaking groups: healthy volunteers: intraclass correlation coefficient = 0.43 (95% CI, -0.18 to 0.62); neurology patients: 0.90 (95% CI, 0.82-0.95); and ICU patients able to speak: 0.86 (95% CI, 0.70-0.92). The interrater and intrarater reliabilities were good (0.95 [0.87-0.98] and 0.94 [0.31-0.99], respectively). In all populations, a Bland-Altman analysis showed systematically higher scores using the multiple-choice Mini Mental State Examination. Administration of the multiple-choice Mini Mental State Examination to ICU patients was straightforward and produced exploitable results comparable to those of the standard Mini Mental State Examination. It should be of interest for the assessment and monitoring of the neurocognitive

  2. Summer Mini Atomiade June 2016

    CERN Multimedia

    Staff Association

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June. ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute. Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has now taken on the challenge of organising a Mini Atomiade from Friday June 3rd to Monday June 6th 2016 in Divonne-les-Bains. The games are made up of four different tournaments/competitions: Small Fi...

  3. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    Science.gov (United States)

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  4. The Utility of the Mini-Addenbrooke's Cognitive Examination as a Screen for Cognitive Impairment in Elderly Patients with Chronic Kidney Disease and Diabetes.

    Science.gov (United States)

    Hobson, Peter; Rohoma, Kamel H; Wong, Stephen P; Kumwenda, Mick J

    2016-01-01

    We tested the utility of the Mini-Addenbrooke's Cognitive Examination (M-ACE) in a cohort of older adults with chronic kidney disease (CKD) and diabetes. The M-ACE was administered to 112 CKD and diabetes patients attending a nephrology clinic. Cognitive impairment was based upon patient, informant, and case review, neuropsychological assessment, and application of criteria for mild cognitive impairment (MCI) and the Diagnostic and Statistical Manual of Mental Disorders, fifth edition for dementia. The M-ACE was also compared to the Mini-Mental State Examination (MMSE). Upon assessment, 52 patients had normal cognitive function, 33 had MCI, and 27 had dementia. The area under the receiver operating curve for the M-ACE was 0.96 (95% CI 0.95-1.00). The sensitivity and specificity for a dementia diagnosis were 0.96 and 0.84 at the cut point <25 and 0.70 and 1.00 at the cut point <21. Mean M-ACE scores differed significantly between normal, demented, and MCI groups ( p < 0.001), and compared to the MMSE, the M-ACE did not suffer from ceiling effects. The M-ACE is an easily administered test with good sensitivity and specificity to capture and assist in the diagnosis of MCI or dementia in patients with CKD and diabetes.

  5. First case report of staghorn calculi successfully removed by mini-endoscopic combined intrarenal surgery in a 2-year-old boy.

    Science.gov (United States)

    Taguchi, Kazumi; Hamamoto, Shuzo; Okada, Atsushi; Mizuno, Kentaro; Tozawa, Keiichi; Hayashi, Yutaro; Kohri, Kenjiro; Yasui, Takahiro

    2015-10-01

    Less-invasive therapy for pediatric urolithiasis is available due to the miniaturization of equipment and improved optics; however, surgical treatment strategies, especially for large calculi, remain controversial. We describe here our experience of treating a 2-year-old boy with left renal staghorn calculi with a single session of mini-endoscopic combined intrarenal surgery in the prone split-leg position with pre-ureteral stenting and the directional enhanced flow imaging ultrasound technique. This is the first report of successful pediatric mini-endoscopic combined intrarenal surgery without any major complications. We believe this technique provides an important therapeutic option for large renal calculus in pediatric patients. © 2015 The Japanese Urological Association.

  6. Mini-open transforaminal lumbar interbody fusion.

    Science.gov (United States)

    Tangviriyapaiboon, Teera

    2008-09-01

    To demonstrate the surgical technique and advantages of the mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation. Clinical and radiographic results were assessed to determine the clinical outcomes in twelve consecutive patients selected for minimally invasive access (mini-open technique) for TLIF in Prasat Neurological Institute. A retrospective analysis was performed on 12 patients (age range, 38-74 yr; mean, 54. 8 yr) who underwent mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation between September 2006 and June 2008. The titanium pedicle screws were introduced bilaterally through the 3.5 cm length, skin incisions with Spine Classics MLD- system retractor, autologous bone graft were inserted to perform TLIF in all patients. Eight patients were augmented anterior column support with titanium interbody cage, unilateral cage insertion in four patients and the others were inserted bilaterally interbody cages. Six patients presented with low back pain and associated radiculopathy, and six presented with low back pain only. Transforaminal lumbar interbody fusion was performed at L3-L4 in two patients, L4-L5 in four patients, L5-S1 in five patients, and two levels fusion in one patient. All patients were able to ambulate after spinal fusion. The patients were able to walk within 1.4 days (range 1-2 days). The hospital stay averaged 4.4 days (range 3-7 days). Periodic follow-up took place 1 to 21 months after surgery (mean, 7.4 months). The radiological fusion was archived in all nine patients who were operated on more than two months age. The other three patients who had been follow-up less than two months were probably fusion on the 1-month followed-up radiological examination. The use of mini-open technique for pedicle screw instrumentation with spinal fusion procedure provides excellent clinical results and may be an operation of choice for

  7. A web-based delphi study for eliciting helpful criteria in the positive diagnosis of hemophagocytic syndrome in adult patients.

    Science.gov (United States)

    Hejblum, Gilles; Lambotte, Olivier; Galicier, Lionel; Coppo, Paul; Marzac, Christophe; Aumont, Cédric; Fardet, Laurence

    2014-01-01

    The diagnosis of the reactive form of hemophagocytic syndrome in adults remains particularly difficult since none of the clinical or laboratory manifestations are specific. We undertook a study in order to elicit which features constitute helpful criteria for a positive diagnosis. In this Delphi study, the features investigated in the questionnaire and the experts invited to participate in the survey were issued from a bibliographic search. The questionnaire was iteratively proposed to experts via a web-based application with a feedback of the results observed at the preceding Delphi round. Experts were asked to label each investigated criterion in one of the following categories: absolutely required, important, of minor interest, or not assessable in the routine practice environment. A positive consensus was a priori defined as at least 75% answers observed in the categories absolutely required and important. The questionnaire investigated 26 criteria and 24 experts originating from 13 countries participated in the second and final Delphi round. A positive consensus was reached for the nine following criteria: unilineage cytopenia, bicytopenia, pancytopenia, presence of hemophagocytosis pictures on a bone marrow aspirate or on a tissue biopsy, high ferritin level, fever, organomegaly, presence of a predisposing underlying disease, and high level of lactate dehydrogenase. A negative consensus was reached for 13 criteria, and an absence of consensus was observed for 4 criteria. The study constitutes the first initiative to date for defining international guidelines devoted to the positive diagnosis of the reactive form of hemophagocytic syndrome.

  8. Validation Study of the Mini-Mental State Examination in Urdu Language for Pakistani Population.

    Science.gov (United States)

    Awan, Safia; Shahbaz, Naila; Akhtar, Syed Wasim; Ahmad, Arsalan; Iqbal, Sadaf; Ahmed, Sellal; Naqvi, Haider; Wasay, Mohammad

    2015-01-01

    Validation study of the Mini-Mental State Examination in Urdu language for Pakistani population. This study was conducted primarily to validate and determine the optimal cutoff score in the diagnosis of dementia among Pakistani's and study the effects of gender and education on the MMSE performance in our population. Four hundred participants took part in the study. Patient with dementia recruited from five major hospitals from Pakistan. The MMSE was translated into Urdu. There were 61 men and 39 women in dementia group and 225 men and 75 women in the control group. The mean score of Urdu MMSE were lower in patients with dementia 18.5 ± 5.6 (range 0-30) as compared to the controls 26.8 ± 2.6 (range 7-30). This difference between groups was statistically significant (p<0.001). Educational based MMSE score below 15 yielded perfect sensitivity and specificity for the diagnosis of dementia. These finding confirm the influence of level of education on MMSE score and education stratified cutoff scores should be used while screening for cognitive impairment in this population.

  9. Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos

    Energy Technology Data Exchange (ETDEWEB)

    Faria, M.T.C. [Universidade Federal de Minas Gerais (DEMEC/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica], Email: mtcdf@uol.com.br; Martinez, C.B.; Viana, E.M.F. [Universidade Federal de Minas Gerais (EHR-UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Hidraulica e Recursos Hidricos], Emails: martinez@cce.ufmg.br, ednamariafaria@bol.com.br

    2009-07-01

    This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

  10. Methods for roof-top mini-arrays

    Science.gov (United States)

    Hazen, W. E.; Hazen, E. S.

    1985-08-01

    To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

  11. Styles of coping with cancer: the Italian version of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale.

    Science.gov (United States)

    Grassi, Luigi; Buda, Patrizia; Cavana, Laura; Annunziata, Maria Antonietta; Torta, Riccardo; Varetto, Antonella

    2005-02-01

    Mental adjustment to cancer has been explored in a large body of the literature by using the Mental Adjustment to Cancer (MAC) scale. Problems in the factor structure of the scale and the need for refining the instrument have determined the development of the Mini-MAC. The aim of this study was to validate, according to a test-oriented approach, the Italian version of the Mini-MAC. Four hundred and thirty cancer patients in five centres in Northern Italy completed the Mini-MAC and the Brief Symptom Inventory (BSI). A subgroup of 153 patients filled out the instruments again within 3 months of the first assessment. The five original subscales (Fighting Spirit, Hopeless, Fatalism, Anxious Preoccupation and Cognitive Avoidance) showed acceptable levels of reliability (Cronbach alpha coefficients ranging from 0.55 to 0.80) although alphas were lower for the scales Fighting Spirit and Fatalism. Factor analysis (Varimax rotation) identified the same five factors with minor variations from the original version. Again, alpha coefficients were less robust for the factors Fighting Sprit and Fatalism. Hopeless and Anxious Preoccupation were significantly related to all the BSI psychological stress symptoms, including the Global Stress Index (GSI). Test-retest reliability showed no differences in the sub-scales scores between assessments. Copyright (c) 2004 John Wiley & Sons, Ltd.

  12. Protective factor screening for prevention practice: Sensitivity and specificity of the DESSA-Mini.

    Science.gov (United States)

    Shapiro, Valerie B; Kim, B K Elizabeth; Robitaille, Jennifer L; LeBuffe, Paul A

    2017-12-01

    The Devereux Student Strengths Assessment Mini (DESSA-Mini; Naglieri, LeBuffe, & Shapiro, 2011/2014) was designed to overcome practical obstacles to universal prevention screening. This article seeks to determine whether an entirely strength-based, 8-item screening instrument achieves technical accuracy in routine practice. Data come from a district-wide implementation of a new social emotional learning (SEL) initiative designed to promote students' social-emotional competence. All students, kindergarten through Grade 8, were screened using the DESSA-Mini. A random 5 students per classroom received additional assessment. Concurrent and predictive criterion studies were conducted using the full DESSA as well as administrative records of serious disciplinary infraction. The DESSA-Mini showed excellent internal reliability, exceeding .90. Negligible to small differences were found between scores on the DESSA-Mini screen and the DESSA full assessment. Classification consistency between the DESSA-Mini and the DESSA was high (87%-94%) in routine practice, with sensitivity and specificity estimates exceeding Glascoe's (2005) standards. Finally, predictive validity of the DESSA-Mini was reliable; students screened as having a Need for SEL Instruction at the beginning of the year were 4.5 times more likely to have a record of serious disciplinary infraction at the end of the school year compared with those who were not identified (p mental, emotional, and behavioral problems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Estimation of the frequency of positive biopsies for cancer in patients with diagnosis by images of breast lesion BIRADS 3, Hospital Mexico, 2007-2009

    International Nuclear Information System (INIS)

    Obando Valverde, Aiza

    2013-01-01

    The histopathological findings have been described in patients with diagnosis by images of BIRADS 3, at the Hospital Mexico during the years 2007-2009. The histopathological findings have enrolled patients with diagnosis by images of lesion probably benign. The percentage of positive biopsies for cancer in patients BIRADS 3 was determined and compared the finding, with data found in the international literature. The stadium has been determined at the time of positive histopathological diagnosis for cancer in patients with breast lesions scheduled by images as BIRADS 3. The findings of the present study have recollected without enough evidence to justify taking biopsies, suggesting that conservative management would be sufficient for diagnosis approach of lesions BIRADS 3 [es

  14. Mini-conference on Angular Momentum Transport in Laboratory and Nature

    International Nuclear Information System (INIS)

    Ji, Hantao; Kronberg, Philipp; Prager, Stewart C.; Uzdensky, Dmitri A.

    2008-01-01

    This paper provides a concise summary of the current status of the research and future perspectives discussed in the Mini-Conference on Angular Momentum Transport in Laboratory and Nature. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2007 Annual Meeting (November 12-16, 2007). This Mini-conference covers a wide range of phenomena happening in fluids and plasmas, either in laboratory or in nature. The purpose of this paper is not to comprehensively review these phenomena, but to provide a starting point for interested readers to refer to related research in areas other than their own

  15. Rational Design of Mini-Cas9 for Transcriptional Activation.

    Science.gov (United States)

    Ma, Dacheng; Peng, Shuguang; Huang, Weiren; Cai, Zhiming; Xie, Zhen

    2018-04-20

    Nuclease dead Cas9 (dCas9) has been widely used for modulating gene expression by fusing with different activation or repression domains. However, delivery of the CRISPR/Cas system fused with various effector domains in a single adeno-associated virus (AAV) remains challenging due to the payload limit. Here, we engineered a set of downsized variants of Cas9 including Staphylococcus aureus Cas9 (SaCas9) that retained DNA binding activity by deleting conserved functional domains. We demonstrated that fusing FokI nuclease domain to the N-terminal of the minimal SaCas9 (mini-SaCas9) or to the middle of the split mini-SaCas9 can trigger efficient DNA cleavage. In addition, we constructed a set of compact transactivation domains based on the tripartite VPR activation domain and self-assembled arrays of split SpyTag:SpyCatch peptides, which are suitable for fusing to the mini-SaCas9. Lastly, we produced a single AAV containing the mini-SaCas9 fused with a downsized transactivation domain along with an optimized gRNA expression cassette, which showed efficient transactivation activity. Our results highlighted a practical approach to generate down-sized CRISPR/Cas9 and gene activation systems for in vivo applications.

  16. Targeted CNS delivery using human MiniPromoters and demonstrated compatibility with adeno-associated viral vectors

    Directory of Open Access Journals (Sweden)

    Charles N de Leeuw

    2014-01-01

    Full Text Available Critical for human gene therapy is the availability of small promoters tools to drive gene expression in a highly specific and reproducible manner. We tackled this challenge by developing human DNA MiniPromoters (MiniPs using computational biology and phylogenetic conservation. MiniPs were tested in mouse as single-copy knock-ins at the Hprt locus on the X chromosome and evaluated for lacZ reporter expression in central nervous system (CNS and non–CNS tissue. Eighteen novel MiniPs driving expression in mouse brain were identified, 2 MiniPs for driving pan-neuronal expression and 17 MiniPs for the mouse eye. Key areas of therapeutic interest were represented in this set: the cerebral cortex, embryonic hypothalamus, spinal cord, bipolar and ganglion cells of the retina, and skeletal muscle. We also demonstrated that three retinal ganglion cell MiniPs exhibit similar cell type specificity when delivered via adeno-associated virus vectors intravitreally. We conclude that our methodology and characterization has resulted in desirable expression characteristics that are intrinsic to the MiniPromoter, not dictated by copy-number effects or genomic location, and results in constructs predisposed to success in adeno-associated virus. These MiniPs are immediately applicable for preclinical studies toward gene therapy in humans and are publicly available to facilitate basic and clinical research, and human gene therapy.

  17. Significant changes in sexual behavior after a diagnosis of human papillomavirus-positive and human papillomavirus-negative oral cancer.

    Science.gov (United States)

    Taberna, Miren; Inglehart, Ronald C; Pickard, Robert K L; Fakhry, Carole; Agrawal, Amit; Katz, Mira L; Gillison, Maura L

    2017-04-01

    Sexual behavior and oral human papillomavirus (HPV) infection are risk factors for oral squamous cell carcinoma (OSCC). The effects of OSCC diagnosis and treatment on subsequent relationship stress and sexual behavior are unknown. Incident cases of HPV-positive or HPV-negative OSCC in patients who had a partnered relationship and partners of patients with oropharyngeal cancer were eligible for a study in which surveys were administered at diagnosis and at the 6-month follow-up time point to assess relationship distress, HPV transmission and concerns about health consequences, and sexual behavior. The frequency distributions of responses, stratified by tumor HPV status, were compared at baseline and follow-up. In total, 262 patients with OSCC and 81 partners were enrolled. Among the patients, 142 (54.2%) had HPV-positive OSCC, and 120 (45.8%) had HPV-negative OSCC. Relationship distress was infrequently reported, and 69% of patients felt that their relationship had strengthened since the cancer diagnosis. Both HPV-positive patients (25%) and their partners (14%) reported feelings of guilt or responsibility for the diagnosis of an HPV-caused cancer. Concern over sexual, but not nonsexual, HPV transmission to partners was reported by 50%. Significant declines in the frequency of vaginal and oral sexual behaviors were reported at follow-up, regardless of tumor HPV status. From baseline to 6 months, significant increases in abstinence from vaginal sex (from 10% to 34%; P oral sex (from 25% to 80%; P oral sex, regardless of tumor HPV status. Sexual behavior is an important quality-of-life outcome to assess within clinical trials. [See related editorial on pages 000-000, this issue.] Cancer 2017. © 2017 American Cancer Society. Cancer 2017;123:1156-1165. © 2016 American Cancer Society. © 2017 American Cancer Society.

  18. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Directory of Open Access Journals (Sweden)

    LuisJoaquín Garcia-Lopez

    Full Text Available Social Anxiety Disorder (SAD is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain.The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1 and clinical sample (study 2.Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls. Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency.Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  19. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T A

    2015-01-01

    Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  20. Arc-to-arc mini-sling 1999: a critical analysis of concept and technology

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2011-04-01

    Full Text Available PURPOSE: The aim of this study was to critically review the Arc-to-Arc mini-sling (Palma's technique a less invasive mid-urethral sling using bovine pericardium as the sling material. MATERIALS AND METHODS: The Arc-to-Arc mini-sling, using bovine pericardium, was the first published report of a mini-sling, in 1999. The technique was identical to the "tension-free tape" operation, midline incision and dissection of the urethra. The ATFP (white line was identified by blunt dissection, and the mini-sling was sutured to the tendinous arc on both sides with 2 polypropylene 00 sutures. RESULTS: The initial results were encouraging, with 9/10 patients cured at the 6 weeks post-operative visit. However, infection and extrusion of the mini-sling resulted in sling extrusion and removal, with 5 patients remaining cured at 12 months. CONCLUSION: The Arc-to-Arc mini-sling was a good concept, but failed because of the poor technology available at that time. Further research using new materials and better technology has led to new and safer alternatives for the management of stress urinary incontinence.

  1. Performance and internal flow condition of mini centrifugal pump with splitter blades

    International Nuclear Information System (INIS)

    Shigemitsu, T; Fukutomi, J; Kaji, K; Wada, T

    2012-01-01

    Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from the experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. The blade-to-blade low velocity regions are suppressed in the case with the splitter blades and the total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.

  2. Effect of recycling protocol on mechanical strength of used mini-implants.

    Science.gov (United States)

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al2O3-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.

  3. Mini-implants in the palatal slope – a retrospective analysis of implant survival and tissue reaction

    Directory of Open Access Journals (Sweden)

    Ziebura Thomas

    2012-11-01

    Full Text Available Abstract Background To identify insertion procedure and force application related complications in Jet Screw (JS type mini-implants when inserted in the palatal slope. Methods Setting and Sample Population: The Department of Orthodontics, the University Hospital Münster. Forty-one consecutively started patients treated using mini-implants in the palatal slope. In this retrospective study, 66 JS were evaluated. Patient records were used to obtain data on the mode of utilization and complications. Standardized photographs overlayed with a virtual grid served to test the hypothesis that deviations from the recommended insertion site or the type of mechanics applied might be related to complications regarding bleeding, gingival overgrowth or implant failure. Results Two implants (3% were lost, and two implants (3%, both loaded with a laterally directed force, exhibited loosening while still serving for anchorage. Complications that required treatment did not occur, the most severe problem observed being gingival proliferation which was attributable neither to patients’ age nor to applied mechanics or deviations from the ideal implant position. Conclusions The JS mini-implant is reliable for sagittal and vertical movements or anchorage purposes. Laterally directed forces might be unfavorable. The selection of implant length as well as the insertion procedure should account for the possibility of gingival overgrowth.

  4. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  5. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  6. Detection of EpCAM-positive microparticles in pleural fluid: A new approach to mini-invasively identify patients with malignant pleural effusions

    OpenAIRE

    Roca, Elisa; Lacroix, Romaric; Judicone, Coralie; Laroumagne, Sophie; Robert, St?phane; Cointe, Sylvie; Muller, Alexandre; Kaspi, Elise; Roll, Patrice; Brisson, Alain R.; Tantucci, Claudio; Astoul, Philippe; Dignat-George, Fran?oise

    2015-01-01

    Pleural biomarkers allowing to mini-invasively discriminate benign from malignant pleural effusions are needed. Among potential candidates, microparticles (MPs) are extracellular vesicles that vectorize antigen derived from the parent cell. We hypothesized that tumor-derived MPs could be present in the pleural liquid and help to identify patients with malignant pleural effusions. Using highly sensitive flow cytometry and cryo-electron microscopy, we showed that large amounts of MPs from hemat...

  7. "Mini", "Midi" and the Student.

    Science.gov (United States)

    Edwards, Perry; Broadwell, Bruce

    Mini- and midi-computers have been introduced into the computer science program at Sierra College to afford students more direct contact with computers. The college's administration combined with the Science and Business departments to share the expense and utilization of the program. The National Cash Register Century 100 and the Data General…

  8. Social context surrounding HIV diagnosis and construction of masculinity: a qualitative study of stigma experiences of heterosexual HIV positive men in southwest Nigeria

    Directory of Open Access Journals (Sweden)

    Titilayo Ainegbesua Okoror

    2016-06-01

    Full Text Available Abstract Background Though research has documented experiences of stigma and its effects on the lives of women living with HIV/AIDS, there is limited research on heterosexual positive HIV men experience of stigma in Nigeria. This study explored how social context surrounding HIV diagnosis impacts stigma experiences of heterosexual HIV positive men and their construction of masculinity in southwest Nigeria. Methods Using purposive sampling, 17 heterosexual HIV positive men were recruited through community based organization to participate in two hours focus group discussions or 45 min in-depth interviews that were audio-recorded. Without using the word stigma, discussions and interviews were guided by four questions that explored participants’ experiences of living with HIV/AIDS. Interviews and discussions were conducted in three languages: English, Yoruba and Pidgin English. Thematic data analysis approach was in coding transcribed data, while social constructivist thinking guided data analysis. Results Participants ranged in age from 30 to 57 years old, and all were receiving antiretroviral therapy. Findings indicated that participants’ experiences of stigma might be moderated by the social context surrounding their HIV diagnosis, and whether they have met the socio-cultural construction of masculinity. Participants whose diagnosis were preceded by immediate family members’ diagnosis were less likely to report experiencing HIV stigma and more likely to report “not feeling less than a man” and educating others about HIV/AIDS. Contrarily, participants whose diagnosis was preceded by their own sickness were more likely to report isolation, sigma and feeling of being less than a man. All participants reported limiting their sexual intimacy, and those with children reported adjusting how they performed their role as fathers. Conclusions Social context surrounding HIV diagnosis impact how heterosexual HIV positive men experience HIV

  9. Social context surrounding HIV diagnosis and construction of masculinity: a qualitative study of stigma experiences of heterosexual HIV positive men in southwest Nigeria.

    Science.gov (United States)

    Okoror, Titilayo Ainegbesua; Falade, Catherine Olufunke; Walker, Ebunlomo Mary; Olorunlana, Adetayo; Anaele, Agaptus

    2016-06-13

    Though research has documented experiences of stigma and its effects on the lives of women living with HIV/AIDS, there is limited research on heterosexual positive HIV men experience of stigma in Nigeria. This study explored how social context surrounding HIV diagnosis impacts stigma experiences of heterosexual HIV positive men and their construction of masculinity in southwest Nigeria. Using purposive sampling, 17 heterosexual HIV positive men were recruited through community based organization to participate in two hours focus group discussions or 45 min in-depth interviews that were audio-recorded. Without using the word stigma, discussions and interviews were guided by four questions that explored participants' experiences of living with HIV/AIDS. Interviews and discussions were conducted in three languages: English, Yoruba and Pidgin English. Thematic data analysis approach was in coding transcribed data, while social constructivist thinking guided data analysis. Participants ranged in age from 30 to 57 years old, and all were receiving antiretroviral therapy. Findings indicated that participants' experiences of stigma might be moderated by the social context surrounding their HIV diagnosis, and whether they have met the socio-cultural construction of masculinity. Participants whose diagnosis were preceded by immediate family members' diagnosis were less likely to report experiencing HIV stigma and more likely to report "not feeling less than a man" and educating others about HIV/AIDS. Contrarily, participants whose diagnosis was preceded by their own sickness were more likely to report isolation, sigma and feeling of being less than a man. All participants reported limiting their sexual intimacy, and those with children reported adjusting how they performed their role as fathers. Social context surrounding HIV diagnosis impact how heterosexual HIV positive men experience HIV related stigma and how they perceive themselves as men, which may influence their

  10. Mini International Neuropsychiatric Interview (MINI): validação de entrevista breve para diagnóstico de transtornos mentais

    OpenAIRE

    Amorim, Patrícia

    2000-01-01

    Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos), compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas). A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudo...

  11. Mandibular Overdentures Retained by Two Mini-Implants: A Seven-Year Retention and Satisfaction Study.

    Science.gov (United States)

    Catalán, Alfonso; Martínez, Alejandra; Marchesani, Francisco; González, Urcesino

    2016-07-01

    Patients with atrophic edentulous ridges generally have problems with retention, therapeutic satisfaction, and comfort with their complete dentures. An alternative treatment to assist in improving retention and stability involves the use of mini-implants. The aim of this study was to evaluate the retention of mandibular overdentures connected to two mini-implants and overall patient satisfaction with them. Seven patients with atrophic mandibular ridges (Type 4D Misch classification), aged 62 to 74 years old were rehabilitated with complete dentures. In each patient, two mini-implants measuring 15 or 13 mm in length and 1.8 mm in diameter were placed. After 15 days, overdentures were connected to the mini-implants with O-ring attachments. In each patient, retention of the overdentures was measured, and a survey of therapeutic satisfaction before and after connection to the mini-implants was administered. Prosthesis retention was measured with a digital dynamometer at 1 month, 6 months, and 2, 3, 5, and 7 years after mini-implant placement. Patient satisfaction was assessed with a survey. Data were analyzed with Student's t-test (satisfaction survey) and the Friedman test (retention measurements and satisfaction survey). The initial retention values (0.34 to 0.63 N without mini-implants) varied significantly (p ≤ 0.050). These values were less than the subsequent measurements of 3.92 to 9.64 N, taken after placement of the mini-implants and connecting them to the dentures. Satisfaction was good to very good over the 7-year observation period. Mucosa and peri-implant bone showed no pathological changes. In this limited sample size clinical study the results indicated that after connecting mandibular overdentures to two mini-implants, patient satisfaction significantly increased and retention significantly improved during the 7-year observation period. © 2015 by the American College of Prosthodontists.

  12. In-house PCR with DNA extracted directly from positive slides to confirm or exclude the diagnosis of tuberculosis: focus on biosafety.

    Science.gov (United States)

    de Almeida, Isabela Neves; Aleixo, Agdemir Valéria; Carvalho, Wânia da Silva; de Miranda, Silvana Spindola

    2015-01-01

    The possibility to obtain DNA from smears is a valuable alternative to remedy the lack of samples when they are totally used for bacilloscopy; this technique solves the biosafety problem related to a possible accident with the transportation of flasks containing potentially transmissible clinical samples. Hence, the purpose of this study was to utilize the insertion sequence IS6110 for amplification of DNA from a smear-positive sample for tuberculosis (TB) diagnosis. Among the 52 positive bacilloscopies, sensitivity, specificity, positive predictive value and negative predictive value were 52.3%, 100%, 100% and 89.7%, respectively whereas accuracy was 90.7%. The IS6110-based PCR for TB diagnosis developed in DNA extracted from a positive smear is a fast, simple, specific, and safe method. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Mini transverse versus longitudinal incision in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Korkmaz, M.; Cepoglu, M.C.

    2013-01-01

    Objective: To evaluate the effectiveness of mini-transverse compared with mini-longitudinal incision for carpal tunnel release (CTR) with reference to postoperative functional capacity, symptom severity and complication rate. Study Design: Analytical study. Place and Duration of Study: Cumhuriyet University Medical Faculty, Department of Orthopaedics, Tokat State Hospital, Department of Orthopaedics and Medical Park Tokat Hospital, Department of Neurosurgery, from January 2007 to January 2009. Methodology: This study included 93 hands of 79 patients with carpal tunnel syndrome (CTS), which were operated between 2007 and 2009. Patients were divided according to incision types into Group-1 (undergoing mini-longitudinal incision) and Group-2 (undergoing mini-transverse incision). Patients were evaluated initially and at 3 weeks after treatment according to symptom severity and functional status of Boston Questionnaire (BQ). Demographic and clinical data were analyzed and compared statistically between two groups. Results: Statistically significant differences were observed in BQ symptom and functional scores between the pre- and postoperative period (p < 0.0001). BQ symptom and functional scores at postoperative period were better in Group-1 than Group-2 (p = 0.044 and p = 0.023 respectively). The scar hypersensitivity (p = 0.258) and tenderness (p = 1.00) associated with the incision sites were not statistically different. Conclusion: Longitudinal incision is more effective on symptom and functional conditions than transverse incision. However, there was less scar formation with transverse incision. (author)

  14. Eficacia del proceso de esterilización de los Mini-Endo-bloc

    Directory of Open Access Journals (Sweden)

    Maritza Eraso Rodríguez

    2017-01-01

    Full Text Available El Mini-Endo-Bloc® es un elemento usado para mediar las limas durante la endodoncia, presenta muchas concavidades y orificios que dificultan el proceso de esterilización y pueden promover la infección cruzada o comprometer el pronóstico del tratamiento endodóntico. Objetivo: Observar la eficacia de la esterilización de los Mini-Endo-Bloc® utilizados en la clínica de la Federación Odontológica Colombiana (FOC. Métodos: Se recolectaron 60 Mini-Endo-Bloc® utilizados en pacientes que presentaban diagnósticos de necrosis pulpar y periodontitis apical, lo cuales se dividieron en dos grupos: Grupo control: 12 Mini-Endo-Bloc® desinfectados y no esterilizados. Grupo experimental: 48 Mini-Endo-Bloc® desinfectados y esterilizados, se realizó, según lo recomendado por la Farmacopea USPXXXV, prueba de esterilidad en Caldo Thioglycollate a 37°C, medio de caldo Casoy a 37°C y medio de caldo Casoy a 25°C para determinar presencia de bacterias, levaduras y hongos. Resultados: Al someter los Mini-Endo-Bloc® al protocolo de esterilización establecido por la FOC y teniendo en cuenta los parámetros de las pruebas de esterilidad, en el grupo experimental el 50% (n=24, fueron reprobadas (crecimiento microorganismos y 50% (n = 24 fueron aprobadas (no crecimiento de microorganismos. Discusión: la mitad de las muestras fueron reprobadas, estos resultados pueden ser por fallas en el proceso de desinfección mecánica manual directa, el cual se dificulta en los Mini-Endo-Bloc®, debido a su estructura y diseño, permitiendo que residuos biológicos permanezcan en la superficie del instrumento, evitando que el vapor saturado entre en contacto con el material o los microorganismos durante la esterilización.

  15. How does feedback in mini-CEX affect students' learning response?

    Science.gov (United States)

    Sudarso, Sulistiawati; Rahayu, Gandes Retno; Suhoyo, Yoyo

    2016-12-19

    This study was aimed to explore students' learning response toward feedback during mini-CEX encounter. This study used a phenomenological approach to identify the students' experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Feedback content and the way of providing feedback on mini-CEX stimulated students' internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students' reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students' increased self-efficacy, attitude, knowledge and clinical skill. Feedback content and the way of providing feedback on mini-CEX stimulates the students' internal processes to do a follow-up on feedback. However, another external factor also affects the students' decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students' learning response.

  16. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T. A.

    2015-01-01

    Objectives Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. Methods The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Results Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Conclusions Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided. PMID:26317695

  17. Mini-implants: alternative for oral rehabilitation of a child with ectodermal dysplasia.

    Science.gov (United States)

    Mello, Bianca Zeponi Fernandes; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Valarelli, Fabrício Pinelli; Oliveira, Thais Marchini

    2015-01-01

    Ectodermal dysplasia is a rare congenital disease that affects several structures of ectodermal origin. The most commonly related oral characteristics are hypodontia, malformed teeth and underdeveloped alveolar ridges. New alternative treatments are needed due to the failure of the conventional prosthesis retention. This case report outlines the oral rehabilitation treatment of a 9-year-old girl with ectodermal dysplasia. The treatment was performed with conventional prosthesis upon mini-implants. The mini-implants provided prosthetic retention. The patient reported a good adaptation of the dental prosthesis and satisfaction with the treatment. The increased self-esteem improved the socialization skills of the girl. In this case report, use of prosthesis with mini-implants was satisfactory for prosthetic retention. However, clinical studies with long-term follow-up are needed to test the mini-implants as an alternative for oral rehabilitation of children with ectodermal dysplasia.

  18. The Lagrangian structure of ozone mini-holes and potential vorticity anomalies in the Northern Hemisphere

    Directory of Open Access Journals (Sweden)

    P. M. James

    2002-06-01

    Full Text Available An ozone mini-hole is a synoptic-scale area of strongly reduced column total ozone, which undergoes a growth-decay cycle in association with baroclinic weather systems. The tracks of mini-hole events recorded during the TOMS observation period over the Northern Hemisphere provide a database for building anomaly fields of various meteorological parameters, following each mini-hole center in a Lagrangian sense. The resulting fields provide, for the first time, a complete mean Lagrangian picture of the three-dimensional structure of typical ozone mini-holes in the Northern Hemisphere. Mini-holes are shown to be associated with anomalous warm anticyclonic flow in the upper troposphere and cold cyclonic anomalies in the middle stratosphere. Ascending air columns occur upstream and descent downstream of the mini-hole centers. Band-pass filtering is used to reveal the transient synoptic nature of mini-holes embedded within larger scale circulation anomalies. Significant correlations between ozone and Ertel’s potential vorticity on isentropes (IPV both near the tropopause and in the middle stratosphere are shown and then utilized by reconstructing the Lagrangian analysis to follow local IPV anomalies instead of ozone minima. By using IPV as a proxy for ozone, the geopotential anomaly dipolar structure in the vertical characteristic of mini-holes is shown to result from a superposition of two largely independent dynamical components, stratospheric and tropospheric, typically operating on different time scales. Hence, ozone mini-holes may be viewed primarily as phenomena of coincidence.Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; synoptic-scale meteorology

  19. The Lagrangian structure of ozone mini-holes and potential vorticity anomalies in the Northern Hemisphere

    Directory of Open Access Journals (Sweden)

    P. M. James

    Full Text Available An ozone mini-hole is a synoptic-scale area of strongly reduced column total ozone, which undergoes a growth-decay cycle in association with baroclinic weather systems. The tracks of mini-hole events recorded during the TOMS observation period over the Northern Hemisphere provide a database for building anomaly fields of various meteorological parameters, following each mini-hole center in a Lagrangian sense. The resulting fields provide, for the first time, a complete mean Lagrangian picture of the three-dimensional structure of typical ozone mini-holes in the Northern Hemisphere. Mini-holes are shown to be associated with anomalous warm anticyclonic flow in the upper troposphere and cold cyclonic anomalies in the middle stratosphere. Ascending air columns occur upstream and descent downstream of the mini-hole centers. Band-pass filtering is used to reveal the transient synoptic nature of mini-holes embedded within larger scale circulation anomalies. Significant correlations between ozone and Ertel’s potential vorticity on isentropes (IPV both near the tropopause and in the middle stratosphere are shown and then utilized by reconstructing the Lagrangian analysis to follow local IPV anomalies instead of ozone minima. By using IPV as a proxy for ozone, the geopotential anomaly dipolar structure in the vertical characteristic of mini-holes is shown to result from a superposition of two largely independent dynamical components, stratospheric and tropospheric, typically operating on different time scales. Hence, ozone mini-holes may be viewed primarily as phenomena of coincidence.

    Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; synoptic-scale meteorology

  20. Investigation of Heat Transfer in Mini Channels using Planar Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Bøgild, Morten Ryge; Poulsen, Jonas Lundsted; Rath, Emil Zacho

    2012-01-01

    In this paper an experimental investigation of the heat transfer in mini channels with a hydraulic diameter of 889 m is conducted. The method used is planar laser induceduorescence (PLIF), which uses the principle of laser excitation of rhodamine B in water. The goal of this study is to validate...... the applicability of PLIF to determine the convective heat transfer coecient in mini channels against conventional correlations of the convective heat transfer coecient. The applicability of the conventional theory in micro and mini channels has been discussed by several researchers, but to the authors knowledge...

  1. Evaluation of the 2007 WHO guideline to improve the diagnosis of tuberculosis in ambulatory HIV-positive adults.

    Science.gov (United States)

    Koole, Olivier; Thai, Sopheak; Khun, Kim Eam; Pe, Reaksmey; van Griensven, Johan; Apers, Ludwig; Van den Ende, Jef; Mao, Tan Eang; Lynen, Lutgarde

    2011-04-06

    In 2007 WHO issued a guideline to improve the diagnosis of smear-negative and extrapulmonary tuberculosis (EPTB) in HIV-positive patients. This guideline relies heavily on the acceptance of HIV-testing and availability of chest X-rays. Cohort study of TB suspects in four tuberculosis (TB) clinics in Phnom Penh, Cambodia. We assessed the operational performance of the guideline, the incremental yield of investigations, and the diagnostic accuracy for smear-negative tuberculosis in HIV-positive patients using culture positivity as reference standard. 1,147 (68.9%) of 1,665 TB suspects presented with unknown HIV status, 1,124 (98.0%) agreed to be tested, 79 (7.0%) were HIV-positive. Compliance with the guideline for chest X-rays and sputum culture requests was 97.1% and 98.3% respectively. Only 35 of 79 HIV-positive patients (44.3%) with a chest X-ray suggestive of TB started TB treatment within 10 days. 105 of 442 HIV-positive TB suspects started TB treatment (56.2% smear-negative pulmonary TB (PTB), 28.6% smear-positive PTB, 15.2% EPTB). The median time to TB treatment initiation was 5 days (IQR: 2-13 days), ranging from 2 days (IQR: 1-11.5 days) for EPTB, over 2.5 days (IQR: 1-4 days) for smear-positive PTB to 9 days (IQR: 3-17 days) for smear-negative PTB. Among the 34 smear-negative TB patients with a confirmed diagnosis, the incremental yield of chest X-ray, clinical suspicion or abdominal ultrasound, and culture was 41.2%, 17.6% and 41.2% respectively. The sensitivity and specificity of the algorithm to diagnose smear-negative TB in HIV-positive TB suspects was 58.8% (95%CI: 42.2%-73.6%) and 79.4% (95%CI: 74.8%-82.4%) respectively. Pending point-of-care rapid diagnostic tests for TB disease, diagnostic algorithms are needed. The diagnostic accuracy of the 2007 WHO guideline to diagnose smear-negative TB is acceptable. There is, however, reluctance to comply with the guideline in terms of immediate treatment initiation.

  2. Mini-tablets versus pellets as promising multiparticulate modified release delivery systems for highly soluble drugs.

    Science.gov (United States)

    Gaber, Dina M; Nafee, Noha; Abdallah, Osama Y

    2015-07-05

    Whether mini-tablets (tablets, diameters ≤6mm) belong to single- or multiple-unit dosage forms is still questionable. Accordingly, Pharmacopoeial evaluation procedures for mini-tablets are lacking. In this study, the aforementioned points were discussed. Moreover, their potential for oral controlled delivery was assessed. The antidepressant venlafaxine hydrochloride (Vx), a highly soluble drug undergoing first pass effect, low bioavailability and short half-life was selected as a challenging payload. In an attempt to weigh up mini-tablets versus pellets as multiparticulate carriers, Vx-loaded mini-tablets were compared to formulated pellets of the same composition and the innovator Effexor(®)XR pellets. Formulations were prepared using various polymer hydrogels in the core and ethyl cellulose film coating with increasing thickness. Mini-tablets (diameter 2mm) showed extended Vx release (<60%, 8h). Indeed, release profiles comparable to Effexor(®)XR pellets were obtained. Remarkably higher coating thickness was required for pellets to provide equivalent retardation. Ethyl cellulose in the core ensured faster release due to polymer migration to the surface and pore formation in the coat. mini-tablets showed higher stability to pellets upon storage. Industrially speaking, mini-tablets proved to be superior to pellets in terms of manufacturing, product quality and economical aspects. Results point out the urgent need for standardized evaluation procedures for mini-tablets. Copyright © 2015. Published by Elsevier B.V.

  3. Change in subjective social status following HIV diagnosis and associated effects on mental and physical health among HIV-positive gay men in Australia.

    Science.gov (United States)

    Heywood, Wendy; Lyons, Anthony

    2017-07-01

    This study investigates the impact of HIV diagnosis on subjective social status and if changes are linked to health outcomes. Two measures of subjective social status, socio-economic and standing in the community were examined in 342 Australian HIV-positive gay men in 2014. Participants recalled ratings at diagnosis were compared with current ratings. Self-reported mental (psychological distress, self-esteem, positive mental health and satisfaction with life) and physical health (self-rated health, CD4 count, viral load). Half of the participants reported improvements in subjective socio-economic status (59%) or standing in the community (52%) since diagnosis, yet one quarter reported socio-economic status (25%) or standing in the community had decreased (23%). Increases in either measure of subjective social status were linked to higher self-esteem, positive mental health, satisfaction with life and better self-rated health. Decreases in subjective social status, however, were strongly linked to poorer outcomes on all mental health measures. Decreases in standing in the community were also associated with poorer physical self-rated health. Most participants reported their subjective social status were the same or better since diagnosis. Changes in subjective social status following diagnosis were strongly linked to mental health outcomes. Those who reported a decrease in subjective social status were particularly vulnerable to mental health problems.

  4. Psychometric Properties of the Persian Adaptation of Mini-Cog Test in Iranian Older Adults.

    Science.gov (United States)

    Rezaei, Mohammad; Rashedi, Vahid; Lotfi, Gohar; Shirinbayan, Peymaneh; Foroughan, Mahshid

    2018-04-01

    The aim of this study was to assess the psychometric properties of the Mini-Cog in Iranian older adults. It was a cross-sectional study; 50 older people with dementia and 50 without dementia who matched for age, gender, and education entered the study. The diagnostic and statistical manual of mental disorders criteria for dementia were used as gold standard. A battery of scales included the abbreviated mental test score (AMTS), the Geriatric Depression Scale, and the Mini-Cog was performed. Validity and reliability of the Mini-Cog determined using the Pearson product-moment correlation coefficient (Pearson's r), Cronbach's alpha, and Receiver Operating Characteristic (ROC) curve analysis. The Persian version of Mini-Cog showed a good inter-rater reliability ( K = 0.76, p Mini-Cog have an acceptable sensitivity, specificity, and substantial overall agreement with the AMTS.

  5. The MiniBIOS model (version 1A4) at the RIVM

    NARCIS (Netherlands)

    Uijt de Haag PAM; Laheij GMH

    1993-01-01

    This report is the user's guide of the MiniBIOS model, version 1A4. The model is operational at the Laboratory of Radiation Research of the RIVM. MiniBIOS is a simulation model for calculating the transport of radionuclides in the biosphere and the consequential radiation dose to humans. The

  6. Parasitic infections on the shore of Lake Victoria (East Africa) detected by Mini-FLOTAC and standard techniques.

    Science.gov (United States)

    Barda, Beatrice; Ianniello, Davide; Zepheryne, Henry; Rinaldi, Laura; Cringoli, Giuseppe; Burioni, Roberto; Albonico, Marco

    2014-09-01

    Helminths and protozoa infections pose a great burden especially in developing countries, due to morbidity caused by both acute and chronic infection. The aim of our survey was to analyze the intestinal parasitic burden in communities from Mwanza region, Tanzania. Subjects (n=251) from four villages on the South of Lake Victoria have been analyzed for intestinal parasites with direct smear (DS), formol-ether concentration method (FECM) and the newly developed Mini-FLOTAC technique; urinary schistosomiasis was also assessed in a subsample (n=151); symptoms were registered and correlation between clinic and infections was calculated by chi-squared test and logistical regression. Out of the subjects screened for intestinal and for urinary parasites, 87% (218/251) were found positive for any infection, 69% (174/251) carried a helminthic and 67% (167/251) a protozoan infection, almost half of them had a double or triple infection. The most common helminths were hookworms, followed by Schistosoma mansoni and Schistosoma haematobium. Among protozoa, the most common was Entamoeba coli followed by Entamoeba histolytica/dispar and Giardia intestinalis. Mini-FLOTAC detected a number of helminth infections (61.7%) higher than FECM (38.6%) and DS (17.9%). Some positive associations with abdominal symptoms were found and previous treatment was negatively correlated with infection. Despite the limited size of the examined population the current study indicates a high prevalence of intestinal parasitic infection in Bukumbi area, Tanzania, and Mini-FLOTAC showed to be a promising diagnostic tool for helminth infections. This high parasitic burden calls for starting a regular deworming programme and other preventive interventions in schools and in the community. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Caracterização de mini-implantes utilizados na ancoragem ortodôntica Characterization of the mini-implants used to orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Luciana Rougemont Squeff

    2008-10-01

    Full Text Available INTRODUÇÃO: o diâmetro reduzido do mini-implante, e a decorrente facilidade na sua inserção, minimizam a possibilidade de erro do operador e de contato entre a rosca do mini-implante e a raiz dentária. Entretanto, o risco de fratura da peça aumenta à medida que seu diâmetro é diminuído. MÉTODOS: neste trabalho foram analisados quatro produtos de marcas nacionais (INP, SIN, Conexão e Neodente e um de marca alemã (Mondeal, com o objetivo de identificar características importantes para o bom desempenho deste recurso como acessório de ancoragem. Foram observados composição e design das peças e realizado o ensaio mecânico de torque até a fratura (estudo in vitro, cujos valores foram submetidos à análise de variância (ANOVA e teste de Tukey. RESULTADOS: os resultados mostraram que todos os mini-implantes testados estão aptos à utilização clínica como reforço de ancoragem ortodôntica.INTRODUCTION: The reduced diameter of the mini-implants and the simplicity of the technique could minimize the operator mistake's possibility and avoid the contact between the thread of the screw and the dental root. In spite of that, it increases the fracture risk because of the diameter's decrease. METHODS: At the present work, mini-implants from five different trade marks, four Brazilian systems (INP, SIN, Conexão and Neodente and a German system (Mondeal were studied to identify important characteristics of this anchorage accessory, like composition, design and resistance to the insertion torque (in vitro. The values obtained from the mechanical torque test were submitted to variance analysis (ANOVA and Tukey's test. RESULTS: All studied groups presented good results and are recommended to orthodontic clinic use.

  8. Post irradiation examination of HANARO nucler mini-element fuel (metallographic and density test)

    International Nuclear Information System (INIS)

    Yoo, Byung Ok; Hong, K. P.; Park, D. G.; Choo, Y. S.; Baik, S. J.; Kim, K. H.; Kim, H. C.; Jung, Y. H.

    2001-05-01

    The post irradiation examination of a HANARO mini-element nuclear fuel, KH96C-004, was done in June 6, 2000. The purpose of this project is to evaluate the in-core performance and reliability of mini-element nuclear fuel for HANARO developed by the project T he Nuclear Fuel Material Development of Research Reactor . And, in order to examine the performance of mini-element nuclear fuel in normal output condition, the post irradiation examination of a nuclear fuel bundle composed by 6 mini nuclear fuel rods and 12 dummy fuel rods was performed. Based on these examination results, the safety and reliability of HANARO fuel and the basic data on the design of HANARO nuclear fuel can be ensured and obtained,

  9. Primary fixation of mini slings: a comparative biomechanical study in vivo

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2012-04-01

    Full Text Available INTRODUCTION AND OBJECTIVES: The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND METHODS: A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control, as follows: TVT-Secur® (Gynecare, USA, Type 1 polypropylene mesh (control; Ophira Mini Sling System® (Promedon, Argentina, Tissue Fixation System® (TFS PTY, Australia, Zipper Sling® and "T device" (Prosurg, USA. The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments. The force was measured in Newtons (N. RESULTS: There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst. CONCLUSION: Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified.

  10. Replacing the AMOR with the miniDOAS in the ammonia monitoring network in the Netherlands

    NARCIS (Netherlands)

    Berkhout, Augustinus J. C.; Swart, Daan P. J.; Volten, Hester; Gast, Lou F. L.; Haaima, Marty; Verboom, Hans; Stefess, Guus; Hafkenscheid, Theo; Hoogerbrugge, Ronald

    2017-01-01

    In this paper we present the continued development of the miniDOAS, an active differential optical absorption spectroscopy (DOAS) instrument used to measure ammonia concentrations in ambient air. The miniDOAS has been adapted for use in the Dutch National Air Quality Monitoring Network. The miniDOAS

  11. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  12. A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    International Nuclear Information System (INIS)

    Liden, Goeran; Surakka, Jouni

    2009-01-01

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

  13. Preparation and Evaluation of Hot-Melt Extruded Patient-Centric Ketoprofen Mini-Tablets.

    Science.gov (United States)

    Alshetaili, Abdullah S; Almutairy, Bjad K; Tiwari, Roshan V; Morott, Joseph T; Alshehri, Sultan M; Feng, Xin; Alsulays, Bader B; Park, Jun-Bom; Zhang, Feng; Repka, Michael A

    2016-01-01

    Bitter tasting drugs represent a large portion of active pharmaceutical ingredients. Mini-tablets are specifically designed for patients with difficulty in swallowing particular in young children up to 10 years of age, geriatric patients and patients with esophagitis. The present study was aimed to prepare, taste-masked mini-tablets, which are easily swallowed dosage forms, primarily to be used by pediatric and geriatric patients. Ketoprofen (10%-50% w/w) and Eudragit® EPO were blended and extruded with a 5-mm strand die and cut into consistent mini-tablets by using an adapted downstream pelletizer. Differential scanning calorimetry and polarized light microscopy-hot stage microscopy studies confirmed that the binary mixtures were miscible under the employed extrusion temperatures. In-vitro release studies showed that drug release was less than 0.5% within the first 2 min in simulated salivary fluid (pH 6.8) and more than 90% in the first 20 min in gastric media (pH 1.0). The results of the electronic tongue analysis were well correlated with the drug release profile of the mini-tablets in the artificial saliva. Scanning electron microscopy revealed no cracks on the surface of the minitablets, confirming that the mini-tablets were compact solids. Chemical imaging confirmed the uniform distribution of ketoprofen inside the polymer matrices. Eudragit® EPO containing ketoprofen at various drug loads were successfully melt extruded into tastedmasked mini-tablets. The reduced drug release at salivary pH correlated well with Astree e-Tongue studies for taste masking efficiency.

  14. Identification of processed Chinese medicinal materials using DNA mini-barcoding.

    Science.gov (United States)

    Song, Ming; Dong, Gang-Qiang; Zhang, Ya-Qin; Liu, Xia; Sun, Wei

    2017-07-01

    Most of Chinese medicinal herbs are subjected to traditional processing procedures, including stir-frying, charring, steaming, boiling, and calcining before they are released into dispensaries. The marketing and identification of processed medicinal materials is a growing issue in the marketplace. However, conventional methods of identification have limitations, while DNA mini-barcoding, based on the sequencing of a short-standardized region, has received considerable attention as a new potential means to identify processed medicinal materials. In the present study, six DNA barcode loci including ITS2, psbA-trnH, rbcL, matK, trnL (UAA) intron and its P6 loop, were employed for the authentication of 45 processed samples belonging to 15 species. We evaluated the amplification efficiency of each locus. We also examined the identification accuracy of the potential mini-barcode locus, of trnL (UAA) intron P6 loop. Our results showed that the five primary barcode loci were successfully amplified in only 8.89%-20% of the processed samples, while the amplification rates of the trnL (UAA) intron P6 loop were higher, at 75.56% successful amplification. We compared the mini-barcode sequences with Genbank using the Blast program. The analysis showed that 45.23% samples could be identified to genus level, while only one sample could be identified to the species level. We conclude that trnL (UAA) p6 loop is a candidate mini-barcode that has shown its potential and may become a universal mini-barcode as complementary barcode for authenticity testing and will play an important role in medicinal materials control. Copyright © 2017 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  15. How does feedback in mini-CEX affect students’ learning response?

    Science.gov (United States)

    Rahayu, Gandes Retno; Suhoyo, Yoyo

    2016-01-01

    Objective This study was aimed to explore students’ learning response toward feedback during mini-CEX encounter. Methods This study used a phenomenological approach to identify the students’ experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Results Feedback content and the way of providing feedback on mini-CEX stimulated students’ internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students’ reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students’ increased self-efficacy, attitude, knowledge and clinical skill. Conclusions Feedback content and the way of providing feedback on mini-CEX stimulates the students’ internal processes to do a follow-up on feedback. However, another external factor also affects the students’ decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students’ learning response. PMID:28008136

  16. Grau de aceitação de mini-implantes por pacientes em tratamento ortodôntico: estudo preliminar The mini-implants acceptance rate by patients in orthodontic treatments: a preliminary study

    Directory of Open Access Journals (Sweden)

    Larissa Bustamante Capucho Brandão

    2008-10-01

    Full Text Available OBJETIVOS: os mini-implantes atualmente representam um grande avanço na Ortodontia, por proporcionarem máxima ancoragem com o mínimo de cooperação dos pacientes. No entanto, ainda existem algumas dúvidas quanto ao uso destes dispositivos temporários de ancoragem no que se refere, principalmente, aos aspectos psicológicos de aceitação pelos pacientes durante o tratamento ortodôntico. METODOLOGIA: dez pacientes adultos, portadores de má oclusão de Classe I, com biprotrusão, que foram submetidos a tratamento ortodôntico com a colocação de quatro mini-implantes nos arcos dentários, entre os primeiros molares e segundos pré-molares superiores e inferiores, responderam a um questionário, com o objetivo de avaliar as condições de aceitação dos mini-implantes. RESULTADOS: as respostas indicaram que a maioria dos pacientes aceitou prontamente o procedimento, estavam satisfeitos e recomendariam para outros pacientes (90%, enquanto 50% tiveram alguma preocupação com os procedimentos cirúrgicos e os outros 50% não relataram nenhum desconforto. O tempo médio de tolerância a partir da colocação foi de 3 dias e a maioria tolerou os implantes durante todo o tratamento ortodôntico. CONCLUSÕES: pôde-se concluir que os mini-implantes foram aceitos de forma positiva pela maioria dos pacientes submetidos ao tratamento ortodôntico.OBJECTIVE: Actually, mini-implants as anchorage resources have been spotlight in Orthodontics, providing maximum anchorage with minimum patient's cooperation. However, there are still some restrictions regarding the use of these temporary anchorage devices, and among these, the psychological aspects and the patient's acceptance, which still not properly evaluated. METHODS: Ten adults patients, with Class I biprotrusion malocclusion, that were submitted to orthodontic treatment with the implantation of four mini-implants, in the dental arches, among upper and lower first molar and second premolar teeth, in

  17. From Rindler horizon to mini black holes at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Ghaffary, Tooraj [Islamic Azad University, Department of Science, Shiraz Branch, Shiraz (Iran, Islamic Republic of)

    2017-02-15

    Recently researchers (A. Sepehri et al., Astrophys. Space Sci. 344, 79 (2013)) have considered the signature of superstring balls near mini black holes at LHC and calculate the information loss for these types of strings. Motivated by their work, we consider the evolution of events in high energy experiments from lower energies for which the Rindler horizon is formed to higher energies in which mini black holes and string balls are emerged. Extending the Gottesman and Preskill method to string theory, we find the information loss for excited strings ''string balls'' in mini black holes at LHC and calculate the information transformation from the collapsing matter to the state of outgoing Hawking radiation for strings. We come to the conclusion that information transformation for high energy strings is complete. Then the thermal distribution of excited strings near mini black holes at LHC is calculated. In order to obtain the total string cross section near black holes produced in proton-proton collision, we multiply the black hole production cross section by the thermal distribution of strings. It is observed that many high energy excited strings are produced near the event horizon of TeV black holes. These excited strings evaporate to standard model particles like Higgs boson and top quark at Hagedorn temperature. We derive the production cross section for these particles due to string ball decay at LHC and consider their decay to light particles like bottom quarks and gluons. (orig.)

  18. Model Pemberdayaan Laboratorium Bank Mini Syariah di Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Eva Fauziah

    2018-03-01

    results showed that the model of empowerment of Mini Sharia Bank laboratory in Higher Education has four models; they are 1 model of secondary empowerment, 2 model primary internal empowerment of student, 3 model of primary internal empowerment of student and lecturer and 4 model of primary external empowerment. This laboratory empowerment model is based on observations at four universities in Java, namely Bandung Islamic University (UNISBA, Islamic University of Malang (UNISMA, UIN Malang and UIN Sunan Ampel Surabaya. Laboratorium Bank Mini Syariah merupakan sarana penunjang dan pelaksana program Tri Dharma Perguruan Tinggi yang diharapkan mampu memberikan kontribusi untuk mengakselerasi perkembangan syariah di Indonesia. Oleh karena itu, pemberdayaan laboratorium Bank Mini Syariah sebagai tempat mengembangkan kompetensi baik dalam bidang intelektual, ketrampilan motorik dan terampil memggunakan alat-alat media perbankan syariah untuk peningkatan kompetensi mahasiswa lulusan keuangan dan perbankan syariah perlu ditelaah. Metode penelitian menggunakan metode kualitatif dengan teknik pengumpulan data observasi mendalam. Analisis data menggunakan analisis domain model spradley. Hasil penelitian menunjukkan bahwa model pemberdayaan laboratorium Bank Mini Syariah di Perguruan Tinggi memiliki empat model yaitu 1. Model pemberdayaan sekunder, 2. Model pemberdayaan primer internal mahasiswa, 3. Model pemberdayaan primer internal mahasiswa dan dosen, dan 4. Model pemberdayaan primer eksternal. Model pemberdayaan laboratorium ini berdasarkan pengamatan pada empat perguruan tinggi di Jawa yaitu Universitas Islam Bandung, Universitas Islam Malang, UIN Malang dan UIN Sunan Ampel Surabaya.

  19. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    International Nuclear Information System (INIS)

    Davis, William; Crewson, Cody; Alexander, Andrew; Cranmer-Sargison, Gavin; Kundapur, Vijayananda

    2016-01-01

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

  20. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    Energy Technology Data Exchange (ETDEWEB)

    Davis, William; Crewson, Cody; Alexander, Andrew; Cranmer-Sargison, Gavin; Kundapur, Vijayananda [University of Saskatchewan Department of Physics and engineering Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics (Canada)

    2016-08-15

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

  1. Neutronics analysis on mini test fuel in the RSG-GAS core

    International Nuclear Information System (INIS)

    Tukiran S; Tagor M Sembiring

    2016-01-01

    Research on UMo fuel for research reactor has been developed. The fuel of research reactor is uranium molybdenum low enrichment with high density. For supporting the development of fuel fabrication, an neutronic analysis of mini fuel plates in the RSG-GAS core was performed. The aim of analysis is to determine the numbers of fuel cycles in the core to know the maximum fuel burn-up. The mini fuel plates of U_7Mo-Al and U_6Zr-Al with densities of 7.0 gU/cc and 5.2 gU/cc, respectively, will be irradiated in the RSG-GAS core. The size of both fuels, namely 630 x 70.75 x 1.30 mm were inserted to the 3 plates of dummy fuel. Before the fuel will be irradiated in the core, a calculation for safety analysis from neutronics and thermal-hydraulics aspects were required. However, in this paper, it will be discussed safety analysis of the U_7Mo-Al and U_6Zr-Al mini fuels from neutronic point of view. The calculation was done using WIMSD-5B and Batan-3DIFF codes. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. If it is compared, the power density of U_7Mo-Al mini fuel is bigger than U_6Zr-Al fuel. (author)

  2. Usefulness of gastroesophageal reflux scintigraphy using the knee-chest position for the diagnosis of gastroesophageal reflux disease

    International Nuclear Information System (INIS)

    Asakura, Yasushi; Imai, Yukinori; Ota, Shinichi; Fujiwara, Kenji; Miyamae, Tatsuya

    2005-01-01

    The aim of this study is to evaluate the usefulness of gastroesophageal reflux (GER) scintigraphy using the knee-chest (KC) position for the diagnosis of gastroesophageal reflux disease (GERD). The study subjects were 37 patients with GERD and 8 healthy volunteers (control group). Endoscopically observed esophageal mucosal breaks were evaluated with the Los Angeles classification. For GER scintigraphy, the subjects ingested liquid yogurt labeled with 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) and water. Imaging was performed in the supine and KC position, and GER was graded as 1-4 according to the extent of GER assessed by scintigraphy. GER scintigraphy revealed no reflux in the control group (specificity: 100%). In the supine position, gastroesophageal reflux was observed in 49% of the patients with GERD, compared to 76% in the KC position. 21 of 23 (91%) patients with erosive esophagitis were shown to have GER with scintigraphy. GER scintigraphy revealed severe reflux (grade 3 or 4) (83%, 10/12) in the patients who had severe mucosal breaks (the Los Angels classification grade C or D). GER scintigraphy detected grade 1 or 2 reflux in 7 of the 14 patients who were endoscopically negative. There was a correlation between the endoscopically determined severity of mucosa and the reflux grade which was determined with GER scintigraphy. GER scintigraphy can detect gastroesophageal reflux with a high sensitivity in the KC position and might be a useful method in the screening and assessment of the severity of this disease. This method would be useful for the diagnosis of GERD in endoscopically negative patients. (author)

  3. Final report of phase 2 'Mini-cogeneration in the flower bulb industry'; Eindrapportage Fase 2 'Mini-WKK in de bloembollensector'

    Energy Technology Data Exchange (ETDEWEB)

    Koolwijk, E. [Cogen Projects, Driebergen-Rijsenburg (Netherlands); Smailbegovic, N. [SenterNovem, Utrecht (Netherlands)

    2009-09-15

    Phase 2 of the project 'mini-cogeneration in the flower bulb industry' is the sequel to the report 'mini-cogeneration in the flower bulb industry. Use of cogeneration in the cultivation and hot bed of tulip and hyacinth', Addressing the incentivisation of the use of cogeneration in the sector and working toward realizing a number of demonstration projects. To this end it is necessary that potential investors are given insight in the feasibility of cogeneration at their business and that their enthusiasm is kindled for the use of cogeneration. This was done by disseminating information in the flower bulb industry about the opportunities of cogeneration and by informing growers about technique, economy and points of interest. [Dutch] Fase 2 van het project 'Mini- WKK in de bloembollensector' is een vervolg op het rapport 'Mini-wkk in de bloembollensector. Toepassing van wkk bij teelt en broei van tulp en hyacint' en richt zich op het stimuleren van de toepassing van WKK in de sector en toewerken naar realisatie van een aantal demonstratieprojecten. Daartoe is het noodzakelijk dat potentiele investeerders inzicht krijgen over de haalbaarheid van WKK op hun bedrijf en geenthousiasmeerd worden voor het gebruik van WKK. Dit is gedaan door informatie in de bollensector te verspreiden over de mogelijkheden van WKK en telers te informeren over techniek, economie en aandachtspunten.

  4. Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat

    Directory of Open Access Journals (Sweden)

    Simic Milena

    2010-11-01

    Full Text Available Abstract Background Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D motion analysis system. In addition, the inter-rater reliability was evaluated. Methods Twenty-five (17 women non-injured participants (mean age 25.6 years, range 18-37 were included. Visual analysis of the medio-lateral knee motion, scored as knee-over-foot or knee-medial-to-foot by two raters, and 3-D kinematic data were collected simultaneously during a single-limb mini squat. Frontal plane 2-D peak tibial, thigh, and knee varus-valgus angles, and 3-D peak hip internal-external rotation, and knee varus-valgus angles were calculated. Results Ten subjects were scored as having a knee-medial-to-foot position and 15 subjects a knee-over-foot position assessed by visual inspection. In 2-D, the peak tibial angle (mean 89.0 (SE 0.7 vs mean 86.3 (SE 0.4 degrees, p = 0.001 and peak thigh angle (mean 77.4 (SE 1.0 vs mean 81.2 (SE 0.5 degrees, p = 0.001 with respect to the horizontal, indicated that the knee was more medially placed than the ankle and thigh, respectively. Thus, the knee was in more valgus (mean 11.6 (SE 1.5 vs 5.0 (SE 0.8 degrees, p 0.90 and 96 between raters. Conclusions Medio-lateral motion of the knee can reliably be assessed during a single-leg mini-squat. The test is valid in 2-D, while the actual movement, in 3-D, is mainly exhibited as increased internal hip rotation. The single-limb mini squat is feasible and easy to administer in the clinical setting and in research to address lower extremity movement quality.

  5. Summer Mini Atomiade in June 2016

    CERN Multimedia

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June.   ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute.  Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has taken on the challenge of organising a Mini Atomiade from Friday 3 June to Monday 6 June 2016 in Divonne-les-Bains. The ga...

  6. Four-stranded mini microtubules formed by Prosthecobacter BtubAB show dynamic instability.

    Science.gov (United States)

    Deng, Xian; Fink, Gero; Bharat, Tanmay A M; He, Shaoda; Kureisaite-Ciziene, Danguole; Löwe, Jan

    2017-07-18

    Microtubules, the dynamic, yet stiff hollow tubes built from αβ-tubulin protein heterodimers, are thought to be present only in eukaryotic cells. Here, we report a 3.6-Å helical reconstruction electron cryomicroscopy structure of four-stranded mini microtubules formed by bacterial tubulin-like Prosthecobacter dejongeii BtubAB proteins. Despite their much smaller diameter, mini microtubules share many key structural features with eukaryotic microtubules, such as an M-loop, alternating subunits, and a seam that breaks overall helical symmetry. Using in vitro total internal reflection fluorescence microscopy, we show that bacterial mini microtubules treadmill and display dynamic instability, another hallmark of eukaryotic microtubules. The third protein in the btub gene cluster, BtubC, previously known as "bacterial kinesin light chain," binds along protofilaments every 8 nm, inhibits BtubAB mini microtubule catastrophe, and increases rescue. Our work reveals that some bacteria contain regulated and dynamic cytomotive microtubule systems that were once thought to be only useful in much larger and sophisticated eukaryotic cells.

  7. 'Mini' total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Avramova, V.; Vassileva, V.; Georgieva, S.; Sultanov, B.

    2006-01-01

    Full text: The total body irradiation (TBI) combined with intensive chemotherapy plays an important role in the preparation of patients for bone marrow transplantation (BMT). The first autologous BMT in Bulgaria was performed in 1997 in the Specialized Pediatric Hospital for Active Treatment (SPHAT) of oncohematological diseases. The first TBI, followed by allogeneic BMT, was carried out in 2002 in the 'Queen Giovanna' University Hospital, after which its routine application as a basic form of large field radiotherapy and a main stage of the conditioning regimen for BMT was started. Fourteen allogeneic BMTs including TBI as a basic conditioning regimen have been performed till May 2006. The objective of the present report is to present the first clinical observations in the Bulgarian oncological practice on 'mini' TBI followed by allogeneic blood stem cell transplantation. During the period October 2005 - May 2006, 'mini' TBI followed by allogeneic BMT was carried out for two patients of the age 43 and 50 years. The diagnosis of both patients was acute non-lymphoblastic leukemia, in the remission stage, after one relapse, respectively. Intensive preceding chemotherapy was applied for both patients. A conditioning regimen was applied including the fludarabine purine analogue (3 x 30 mg/m 2 ) and 200 cGy TBI. It was followed by transplantation of allogeneic cell concentrate containing 2.5 x10 6 /kg CD34+ and 4.0 x10 6 /kg CD34+ blood stem cells of partially compatible family donors (a sister and a son), which were tolerable for the patients without complications. Cyclosporine and mycophelonate mofetile were applied as post-transplantation treatment. Active antibiotic, antiviral, symptomatic and substituting therapy, as well as GvHD prophylaxis was applied for both patients. Good clinical tolerance was recorded for the applied low dose conditioning regimen. The patients were discharged within 30 days in good general condition and stable draft action, with

  8. Socioeconomic position and stage at diagnosis of head and neck cancer - a nationwide study from DAHANCA

    DEFF Research Database (Denmark)

    Olsen, Maja Halgren; Bøje, Charlotte Rotbøl; Kjær, Trille Kristina

    2015-01-01

    socioeconomic position and advanced stage HNSCC at diagnosis. MATERIAL AND METHODS: Men and women with HNSCC diagnosed between 1992 and 2008 were identified in the Danish Head and Neck Cancer Group (DAHANCA) database, which contains detailed information on all cases of HNSCC treated in Denmark. Individual...... information on the following four socioeconomic indicators: highest attained educational level, cohabitation status, disposable income and degree of urbanisation were obtained from Statistics Denmark. For the 9683 cases on which there was full information, we estimated odds ratios (ORs) for a diagnosis...... for hypopharynx cancer patients living in rural areas or provincial cities. Having one or more comorbid conditions was associated with an increased OR for advanced stage oral cancer but with a decreased OR for oropharynx cancer. CONCLUSION: In this nationwide population-based study, socioeconomic differences...

  9. [In vivo digestibility of rice genetically modified with CpTI in WZS mini-pig].

    Science.gov (United States)

    Huang, Qiong; Liu, Haibo; Zhi, Yuan; Gao, Peng; Yy, Zhou; Liu, Shan; Xu, Haibin

    2011-11-01

    To establish a stable in vivo gastrointestinal model of WZS mini-pig to evaluate the digestibility of rice genetically modified with CpTI (Cowpea Trypsin Inhibitor). METHODS; Three WZS mini-pigs were surgically fitted with O-stomach cannula and T-ileum cannula, and fed with soybean (positive control), CpTI rice and its parental rice meals. The pH value of gastric and intestinal fluid was monitored at different time points. The digested protein products were measured with protein gel electrophoresis at different time points. The pH value of gastric contents was rapidly neutralized by the meal to approximately 6.0, then the pH was reduced by HCl secretion,and it subsequently was increased after 4-6 hours. Compared with rice,the increase or decrease of pH after soybean being fed was later. Soybean protein segments 13kD,17kD, 34kD and 50kD could be highly detected in gastric and intestinal fluid at 5-6h after soybean being introduced. The segment 13kD was digested in intestine. However, no any protein segment was found in the gastric fluid 0.25h after rice being fed. There was no any difference in digestibility between the rice genetically modified with CpTI and its parental rice. It is practicable to establish a in vivo model of WZS mini-pig for digestibility. The digestibility of CpTI rice and its parental rice in gastric and intestinal tract in vivo is equivalent.

  10. Olfactory Function, Eating Ability, and Visceral Obesity Associated with MMSE Three Years after Parkinson's Disease Diagnosis.

    Science.gov (United States)

    Vikdahl, M; Domellöf, M E; Forsgren, L; Håglin, L

    2015-11-01

    This study examines whether risk factors for poor nutrition are associated with global cognitive function three years after confirmed Parkinson's disease (PD) diagnosis. The follow-up investigations for this prospective community-based study were conducted three years after PD diagnosis. The study participants lived in Västerbotten County, a region in northern Sweden with 142,000 inhabitants. This study population consisted of 118 PD outpatients from the study of Newly Diagnosed PD in Umeå (NYPUM). Global cognition was assessed with the Mini Mental State Examination (MMSE) at baseline and at follow-up. Anthropometry, nutrition (Mini Nutritional Assessment, MNA, 3-day food registration, 3-FDR), olfactory function (Brief Smell Identification Test, B-SIT), and swallowing, cutting food, and salivation (single questions from the Unified Parkinson's Disease Rating Scale, UPDRS) were used as markers for nutritional status. The MMSE score decreased over three years (-1.06±3.38, p=0.001). Olfactory function at baseline was associated to MMSE at three years (B=0.365, p=0.004). Changes in waist/hip ratio (B=113.29, p=0.017), swallowing (B=1.18, P=0.033), and cutting food (B=-1.80, p=0.000) were associated with MMSE at follow-up. This study indicates that olfactory function, cutting food, swallowing, and visceral obesity are associated with MMSE three years after PD diagnosis.

  11. Mini-Invasive floating metatarsal osteotomy for resistant or recurrent neuropathic plantar metatarsal head ulcers.

    Science.gov (United States)

    Tamir, Eran; Finestone, Aharon S; Avisar, Erez; Agar, Gabriel

    2016-07-11

    Patients with peripheral neuropathy and pressure under a relatively plantar deviated metatarsal head frequently develop plantar foot ulcers. When conservative management with orthotics and shoes does not cure the ulcer, surgical metatarsal osteotomy may be indicated to relieve the pressure and enable the ulcer to heal. The purpose of this study is to evaluate the use of a mini-invasive floating metatarsal osteotomy in treating recalcitrant ulcers or recurrent ulcers plantar to the metatarsal heads in patients with diabetes mellitus (DM) related neuropathy. Computerized medical files of patients with diabetic neuropathy treated with an osteotomy during 2013 and 2014 were retrospectively reviewed. There were 20 osteotomies performed on 17 patients (mean age 58 years). The patients had a diagnosis of DM for a mean of 17 years. All ulcers were University of Texas grade 1A; mean ulcer age was 19 months. After 17/20 operations, the ulcer completely resolved after 6 weeks and did not recur after a mean follow-up of 11.5 months. One patient developed an early post-operative infection with osteomyelitis at the osteotomy site (proximal shaft of the fifth metatarsal) that needed debridement and IV antibiotics. In the other 19 cases, the surgical wound healed within 1 week. Asymptomatic radiological non-union developed in six cases (30 %). Mini-invasive floating metatarsal osteotomy can cure resistant and recurrent University of Texas grade 1A ulcerations plantar to the metatarsal heads in neuropathic patients.

  12. Mini-implants: mechanical resource for molars uprighting

    Directory of Open Access Journals (Sweden)

    Susiane Allgayer

    2013-02-01

    Full Text Available INTRODUCTION: The early orthodontic treatment allows correction of skeletal discrepancies by growth control, and the elimination of deleterious habits, which are risk factors for the development of malocclusions, favoring for the correction of tooth positioning later in a second treatment stage. During development of teeth and occlusion, the mandibular second molars commonly erupt in the oral cavity after all other teeth of the anterior region. In their eruptive process there may be a condition known as tooth impaction, which precludes its complete eruption and requires proper uprighting treatment. The temporary anchorage devices allow disimpaction and movement of these teeth directly to their final position, without the need of patient compliance or reaction movements in other parts of the arch. OBJECTIVE: This paper aims at describing a case report of the treatment of a patient with Angle Class II malocclusion, performed in two phases, in which mini-implants were used for uprighting the impacted mandibular second molars.INTRODUÇÃO: o tratamento ortodôntico precoce permite a correção das discrepâncias esqueléticas por meio do controle de crescimento e a eliminação de hábitos deletérios, que são fatores de risco para o desenvolvimento de más oclusões, que favorecem a correção do posicionamento dentário mais tardiamente, em uma segunda fase do tratamento. Durante o desenvolvimento da dentição e da oclusão, normalmente o segundo molar inferior chega à cavidade bucal após todos os dentes posicionados anteriormente a ele. Durante seu processo eruptivo, pode ocorrer uma condição chamada "impacção dentária", em que sua erupção completa é interrompida, exigindo tratamento apropriado para verticalização. Os dispositivos temporários de ancoragem permitem a desimpacção e a movimentação desses dentes diretamente às suas posições finais, sem a necessidade de cooperação do paciente e sem movimento de reação nas

  13. Neutrinos from the NuMI beamline in the MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, Alexis A.

    2006-01-01

    With the startup of the NuMI beamline early in 2005, the MiniBooNE detector has the unique opportunity to be the first user of an off-axis neutrino beam (110 mrad off-axis). MiniBooNE is assembling a rich sample of neutrino interactions from this source

  14. [Validity and Reliability Studies of Modified Mini Mental State Examination (MMSE-E) For Turkish Illiterate Patients With Diagnosis of Alzheimer Disease].

    Science.gov (United States)

    Babacan-Yıldız, Gülsen; Ur-Özçelik, Emel; Kolukısa, Mehmet; Işık, Ahmet Turan; Gürsoy, Esra; Kocaman, Gülşen; Çelebi, Arif

    2016-01-01

    To investigate the validity and reliability of modified Mini Mental State Examination (MMSE-E) for illiterate patients in a Turkish population with Alzheimer's disease (AD). A total of 107 illiterate patients with Alzheimer's Disease (women: 65, men: 42) and 68 illiterate healthy volunteer subjects (women: 36, men: 32) were included in the study. MMSE-I and Geriatrics Depression Scale were performed on all subjects, Alzheimer patients were also administered Basic Activities of Daily Living (B- ADL). Clinical Dementia Rating (CDR) was used to determine the severity of disease, while a receiver operating characteristic (ROC) analysis was performed to analyze the cut-off scores of MMSE-I, and the positive/negative predictive values that were calculated for the optimal cut-off scores. Internal consistency was measured using Cronbach's coefficient . Additionally, correlations between total MMSE-I score and the CDR, B-ADL, and GDS scores were examined. The MMSE-I scores significantly and inversely correlated with CDR (-0.82, p=0.000) and B-ADL scores (-0.051, p=0.000). The optimal cut-off points of MMSE-I were 23/24, which yielded a sensitivity of 99.0% - %100.0, a specificity of 98.5% - 97.0%, and an AUC of 1.0/1.0, respectively. Reliability of the MMSE-I was high α = 0.70). The total MMSE-I score was able to differentiate the AD group from the control group.

  15. USE OF RENEWABLE SUBSTRATES FOR EX VITRO PRODUCTION OF Melaleuca alternifolia CHEEL CLONAL PLANTS BY MINI-CUTTINGS TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Carlos Andre Stuepp

    2017-12-01

    Full Text Available The Australian species Melaleuca alternifolia Cheel. has a strong commercial importance due to the extraction of essential oils from its leaves used in the cosmetic and pharmaceutical industry. In order to obtain an efficient plant production system of M. alternifolia the mini-cuttings technique and the clonal mini-garden management in the productivity and rooting of mini-cuttings and different substrate compositions were analyzed during all the seasons. Mini-stumps derived from cuttings and grown in pots (2 L, were submitted to successive harvesting of their sprouts during the four seasons (september/2013 to august/2014. From the mini-stumps sprouts mini-cuttings were produced, wich were were planted in plastic tubes and kept in a greenhouse for 45 days. Six substrates were used for planting the mini-cuttings: commercial substrate (S1; substrate composed of 100% carbonized rice husk (CRH (S2; substrate composed of 100% coconut fiber (CF (S3; substrate composed of 50% CF and 50% CRH (S4; substrate composed of 30% CF and 70% CRH (S5; substrate composed of 70% FC and 30% CRH (S6. The high survival of mini-stumps (over 90% and the mini-cuttings production (282 mini-cuttings.m-2.month-1 in the shade house demonstrate the technical feasibility for the species, being summer the most appropriate time to collect propagules. The substrate composed by 70% CF + 30% CRH (S6 shows superior results for vegetative propagation of M. alternifolia (91.7% of rooted mini-cuttings, as the single one to contemplate simultaneously all parameters. Summer is recommended as the best time for rooting of mini-cuttings.

  16. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  17. Mini-interfacial Fracture Toughness of a Multimode Adhesive Bonded to Plasma-treated Dentin.

    Science.gov (United States)

    Ayres, Ana Paula Almeida; Pongprueksa, Pong; De Munck, Jan; Gré, Cristina Parise; Nascimento, Fábio Dupart; Giannini, Marcelo; Van Meerbeek, Bart

    2017-01-01

    To investigate the bonding efficacy of a multimode adhesive to plasma-treated and -untreated (control) dentin using a mini-interfacial fracture toughness (mini-iFT) test. Twenty human molars were used in a split-tooth design (n = 10). The adhesive Scotchbond Universal (SBU; 3M ESPE) was applied in etch-and-rinse (E&R) and self-etch (SE) modes. Mid-coronal dentin was exposed and covered with a standardized smear layer ground to 320 grit. One half of each dentin surface received 15 s of non-thermal atmospheric plasma (NTAP), while the other half was covered with a metallic barrier and kept untreated. Following the E&R mode, dentin was plasma treated immediately after phosphoric acid etching. SBU and a resin-based composite were applied to dentin following the manufacturer's instructions. Six mini-iFT specimens were prepared per tooth (1.5 x 2.0 x 16 to 18 mm), and a single notch was prepared at the adhesive-dentin interface using a 150-μm diamond blade under water cooling. Half of the mini-iFT specimens were immediately loaded until failure in a 4-point bending test, while the other half were first stored in distilled water for 6 months. After testing, the exact dimensions of the notch were measured with a measuring optical microscope, from which ΚIc was determined. Three-way ANOVA revealed higher mini-iFT for SBU applied in E&R than SE mode for both storage times, irrespective of NTAP treatment. Overall, mini-iFT did not decrease for any of the experimental groups upon 6-month aging, while plasma treatment did not show a direct beneficial effect on mini-iFT of SBU applied in either E&R or SE mode.

  18. Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.

    Science.gov (United States)

    Gurdan, Z; Szalma, J

    2018-05-01

    Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.

  19. A cost-effective fluorescence mini-microscope for biomedical applications.

    Science.gov (United States)

    Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali

    2015-01-01

    We have designed and fabricated a miniature microscope from off-the-shelf components and a webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters, such as cell/tissue viability (e.g. live/dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60×, achieves a resolution as high as microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including, but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread application in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required.

  20. Development of a multiparticulate system containing enteric-release mini-tablets of omeprazole

    Directory of Open Access Journals (Sweden)

    Volnei Jose Tondo Filho

    2014-09-01

    Full Text Available The main aim of this study was to develop a multiparticulate system containing mini-tablets of omeprazole formulated with an enteric polymer with pH-dependent solubility. Pre-formulation studies showed good flow and compaction capacity, leading to the production ofhigh quality mini-tablets. The mini-tablets were coated in a fluidized bed with hydroxypropylmethylcellulose /Eudragit(r L30D55 and packed into hard gelatin capsules. The dissolution profile showed gastro-resistance and zero-order kinetics. The dissolution profile for the formulation containing lactose as the diluent and coated with 12% (tablet weight gain of polymer was similar to that ofthe reference drug.

  1. Mini hydro power in Peninsular Malaysia - the past, present and future

    International Nuclear Information System (INIS)

    Bhaskar Kannan

    2006-01-01

    The early development of mini hydro development in Peninsular Malaysia was carried out by the National Electricity Board (NEB) and the projects developed in the 50s and 60s were Ulu Langat (Selangor), Sempam, Kg. Raja , Kuala Terla, and Robinson Falls (all in Pahang). In the 70s the main effort of hydropower development was concentrated on developing major hydropower projects not only to cater to the country increasing demand for electricity but also to the country needs for flood control. This development was feverishly carried out on the Perak River and the prohects built were Temenggor (384 MW), Bersia (72 MW), Kenering (20 MW), Sg Piah (70 MW) and the Kenyir (400 MW) project in Sungai Terengganu. In late 1970s, the government was keen to electrify the rural areas of Peninsular Malaysia and mini hydro power development was thought of as an option to provide electricity to these areas. The Mini Hydro Department of National Electricity Board (MHD) was then formed to undertake the task of planning, developing and implementing mini hydro projects to meet this government aspiration. Table 1 shows the list of projects identified and implemented and its status

  2. The development and evaluation of mini-GEMs - short, focused, online e-learning videos in geriatric medicine.

    Science.gov (United States)

    Garside, Mark J; Fisher, James M; Blundell, Adrian G; Gordon, Adam L

    2018-01-01

    Mini Geriatric E-Learning Modules (Mini-GEMs) are short, focused, e-learning videos on geriatric medicine topics, hosted on YouTube, which are targeted at junior doctors working with older people. This study aimed to explore how these resources are accessed and used. The authors analyzed the viewing data from 22 videos published over the first 18 months of the Mini-GEM project. We conducted a focus group of U.K. junior doctors considering their experiences with Mini-GEMS. The Mini-GEMs were viewed 10,291 times over 18 months, equating to 38,435 minutes of total viewing time. The average viewing time for each video was 3.85 minutes. Learners valued the brevity and focused nature of the Mini-GEMs and reported that they watched them in a variety of settings to supplement clinical experiences and consolidate learning. Watching the videos led to an increase in self-reported confidence in managing older patients. Mini-GEMs can effectively disseminate clinical teaching material to a wide audience. The videos are valued by junior doctors due to their accessibility and ease of use.

  3. Psychometric evaluation of a Dutch version of the Mini PAS-ADD for assessing psychiatric disorders in adults with different levels of intellectual disability.

    Science.gov (United States)

    Janssen, R; Maes, B

    2013-08-01

    People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. A Dutch version of the Mini PAS-ADD, which is a screening instrument for identification of mental health problems in people with ID, was evaluated in terms of internal consistency, interinformant reliability, item grouping and criterion validity based on a large-scale random sample (n = 377) and a clinical sample (n = 99) of adults with ID. The Dutch version of the Mini PAS-ADD showed moderate internal consistency, and moderate concordance among informants. Both aspects of the reliability were comparable for different levels of ID. A factor analysis largely confirmed the scale structure. Concurrent validity with the Reiss Screen for Maladaptive Behavior was high for the Depression, Psychosis and Autism scale. The outcome of the criterion-validity analysis indicated high specificity. The sensitivity for specific psychiatric disorders by the corresponding scales was moderate, but the general sensitivity for the presence of psychopathology on the basis of any of the scales was satisfying. The present research reconfirmed the use of the Mini PAS-ADD as a primary screening device for the identification of mental health problems among people with ID. © 2012 The Authors. Journal of Intellectual Disability Research © 2012 John Wiley & Sons Ltd, MENCAP & IASSID.

  4. Evaluation of the 2007 WHO guideline to improve the diagnosis of tuberculosis in ambulatory HIV-positive adults.

    Directory of Open Access Journals (Sweden)

    Olivier Koole

    Full Text Available BACKGROUND: In 2007 WHO issued a guideline to improve the diagnosis of smear-negative and extrapulmonary tuberculosis (EPTB in HIV-positive patients. This guideline relies heavily on the acceptance of HIV-testing and availability of chest X-rays. METHODS AND FINDINGS: Cohort study of TB suspects in four tuberculosis (TB clinics in Phnom Penh, Cambodia. We assessed the operational performance of the guideline, the incremental yield of investigations, and the diagnostic accuracy for smear-negative tuberculosis in HIV-positive patients using culture positivity as reference standard. 1,147 (68.9% of 1,665 TB suspects presented with unknown HIV status, 1,124 (98.0% agreed to be tested, 79 (7.0% were HIV-positive. Compliance with the guideline for chest X-rays and sputum culture requests was 97.1% and 98.3% respectively. Only 35 of 79 HIV-positive patients (44.3% with a chest X-ray suggestive of TB started TB treatment within 10 days. 105 of 442 HIV-positive TB suspects started TB treatment (56.2% smear-negative pulmonary TB (PTB, 28.6% smear-positive PTB, 15.2% EPTB. The median time to TB treatment initiation was 5 days (IQR: 2-13 days, ranging from 2 days (IQR: 1-11.5 days for EPTB, over 2.5 days (IQR: 1-4 days for smear-positive PTB to 9 days (IQR: 3-17 days for smear-negative PTB. Among the 34 smear-negative TB patients with a confirmed diagnosis, the incremental yield of chest X-ray, clinical suspicion or abdominal ultrasound, and culture was 41.2%, 17.6% and 41.2% respectively. The sensitivity and specificity of the algorithm to diagnose smear-negative TB in HIV-positive TB suspects was 58.8% (95%CI: 42.2%-73.6% and 79.4% (95%CI: 74.8%-82.4% respectively. CONCLUSIONS: Pending point-of-care rapid diagnostic tests for TB disease, diagnostic algorithms are needed. The diagnostic accuracy of the 2007 WHO guideline to diagnose smear-negative TB is acceptable. There is, however, reluctance to comply with the guideline in terms of immediate treatment

  5. Urine-Based Nested PCR for the Diagnosis of Mycobacterium tuberculosis: A Comparative Study Between HIV-Positive and HIV-Negative Patients.

    Science.gov (United States)

    Jamshidi Makiani, Mahin; Davoodian, Parivash; Baghershiroodi, Mahnaz; Nejatizadeh, Abdol Azim; Fakkhar, Farideh; Zangeneh, Mehrangiz; Jahangiri, Nadia

    2016-08-01

    While tuberculosis (TB) can be diagnosed by microscopy and culture, the sensitivity of Ziehl-Neelsen staining is variable and culture results require 4 - 8 weeks to be determined. Polymerase chain reaction (PCR) and its modifications, including nested PCR, might be promising methods for the rapid diagnosis of TB. This study aimed to evaluate the performance of nested PCR on urine samples of human immunodeficiency virus (HIV)-positive and -negative patients with different manifestations of clinical TB. In a prospective study, three early-morning urine samples from 100 patients with pulmonary TB (PTB) or extrapulmonary TB (EPTB) were evaluated using a molecular target with insertion element IS6110, specific to the Mycobacterium tuberculosis genome, and nested PCR was performed. The results were analyzed with SPSS version 22. A total of 100 patients, including 74 (74%) with PTB and 26 (26%) with EPTB, were enrolled. Positive smears were seen in 38 patients (38%). Lymph nodes were the most commonly involved organ in 14 of the 26 (53.8%) EPTB patients (13.5%). Seven (23.1%) of the EPTB patients were HIV-positive. Urine PCR was positive in only 28 patients (28%). Seven HIV-positive patients with PTB showed positive urine PCR results. Moreover, PCR results were positive in only one of the seven HIV-positive subjects with EPTB. Positive PCR results were found in 20 of the 73 HIV-negative patients (27.4%) and in 8 of the 27 HIV-positive patients (29.6%). Therefore, there was no significant difference between the HIV-negative and HIV-positive patients for urine PCR (sensitivity 29.6%, specificity 72.6%; positive and negative predictive values 28% and 72%, respectively; P = 0.138). Nested PCR showed the same sensitivity in HIV-positive and HIV-negative patients. It can be applied as a rapid technique for the diagnosis of TB.

  6. Mathematics authentic assessment on statistics learning: the case for student mini projects

    Science.gov (United States)

    Fauziah, D.; Mardiyana; Saputro, D. R. S.

    2018-03-01

    Mathematics authentic assessment is a form of meaningful measurement of student learning outcomes for the sphere of attitude, skill and knowledge in mathematics. The construction of attitude, skill and knowledge achieved through the fulfilment of tasks which involve active and creative role of the students. One type of authentic assessment is student mini projects, started from planning, data collecting, organizing, processing, analysing and presenting the data. The purpose of this research is to learn the process of using authentic assessments on statistics learning which is conducted by teachers and to discuss specifically the use of mini projects to improving students’ learning in the school of Surakarta. This research is an action research, where the data collected through the results of the assessments rubric of student mini projects. The result of data analysis shows that the average score of rubric of student mini projects result is 82 with 96% classical completeness. This study shows that the application of authentic assessment can improve students’ mathematics learning outcomes. Findings showed that teachers and students participate actively during teaching and learning process, both inside and outside of the school. Student mini projects also provide opportunities to interact with other people in the real context while collecting information and giving presentation to the community. Additionally, students are able to exceed more on the process of statistics learning using authentic assessment.

  7. Medical linear accelerator mounted mini-beam collimator: design, fabrication and dosimetric characterization.

    Science.gov (United States)

    Cranmer-Sargison, G; Crewson, C; Davis, W M; Sidhu, N P; Kundapur, V

    2015-09-07

    The goal of this work was to design, build and experimentally characterize a linear accelerator mounted mini-beam collimator for use at a nominal 6 MV beam energy. Monte Carlo simulation was used in the design and dosimetric characterization of a compact mini-beam collimator assembly mounted to a medical linear accelerator. After fabrication, experimental mini-beam dose profiles and central axis relative output were measured and the results used to validate the simulation data. The simulation data was then used to establish traceability back to an established dosimetric code of practice. The Monte Carlo simulation work revealed that changes in collimator blade width have a greater influence on the valley-to-peak dose ratio than do changes in blade height. There was good agreement between the modeled and measured profile data, with the exception of small differences on either side of the central peak dose. These differences were found to be systematic across all depths and result from limitations associated with the collimator fabrication. Experimental mini-beam relative output and simulation data agreed to better than ± 2.0%, which is well within the level of uncertainty required for dosimetric traceability of non-standard field geometries. A mini-beam collimator has now been designed, built and experimentally characterized for use with a commercial linear accelerator operated at a nominal 6 MV beam energy.

  8. Positive predictive value of peptic ulcer diagnosis codes in the Danish National Patient Registry.

    Science.gov (United States)

    Viborg, Søren; Søgaard, Kirstine Kobberøe; Jepsen, Peter

    2017-01-01

    Diagnoses of peptic ulcer are registered in the Danish National Patient Registry (DNPR) for administrative as well as research purposes, but it is unknown whether the coding validity depends on the location of the ulcer. To validate the International Classification of Diseases, 10 th revision diagnosis codes of peptic ulcer in the DNPR by estimating positive predictive values (PPVs) for gastric and duodenal ulcer diagnoses. We identified all patients registered with a hospital discharge diagnosis of peptic ulcer from Aarhus University Hospital, Denmark, in 1995-2006. Among them, we randomly selected 200 who had an outpatient gastroscopy at the time of ulcer diagnosis. We reviewed the findings from these gastroscopies to confirm the presence of peptic ulcer and its location. We calculated PPVs and corresponding 95% confidence intervals (CIs) of gastric and duodenal ulcer diagnoses, using descriptions from the gastroscopic examinations as standard reference. In total, 182 records (91%) were available for review. The overall PPV of peptic ulcer diagnoses in DNPR was 95.6% (95% CI 91.5-98.1), with PPVs of 90.3% (95% CI 82.4-95.5) for gastric ulcer diagnoses, and 94.4% (95% CI 87.4-98.2) for duodenal ulcer diagnoses. PPVs were constant over time. The PPV of uncomplicated peptic ulcer diagnoses in the DNPR is high, and the location of the ulcers is registered correctly in most cases, indicating that the diagnoses are useful for research purposes.

  9. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

    Science.gov (United States)

    Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto

    2016-01-01

    To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic.

  10. The Mini-EUSO telescope on the ISS

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, Valentina, E-mail: scottiv@na.infn.it; Osteria, Giuseppe

    2017-02-11

    The Mini-EUSO project aims to perform observations of the UV-light night emission from Earth. The UV background produced in atmosphere is a key measurement for any experiment aiming at the observation of Extreme Energy Cosmic Rays (EECR) from space, the most energetic component of the cosmic radiation. The Mini-EUSO instrument will be placed within the International Space Station (ISS) in the Russian Module and measures through a UV transparent window. The instrument comprises a compact telescope with a large field of view, based on an optical system employing two Fresnel lenses for increased light collection. The light is focused onto an array of photo-multipliers and the resulting signal is converted into digital, processed and stored via the electronics subsystems on-board. The instrument is designed and built by the members of the JEM-EUSO collaboration. JEM-EUSO is a wide-angle refractive UV telescope being proposed for attachment to the ISS, which has been designed to address basic problems of fundamental physics and high-energy astrophysics investigating the nature of cosmic rays with energies above 10{sup 20} eV. Mini-EUSO will be able to study beside EECRs a wide range of scientific phenomena including atmospheric physics, strange quark matter and bioluminescence. The mission is approved by the Italian Space Agency and the Russian Space Agency. Scientific, technical and programmatic aspects of this project will be described.

  11. Use of NON-PARAMETRIC Item Response Theory to develop a shortened version of the Positive and Negative Syndrome Scale (PANSS)

    Science.gov (United States)

    2011-01-01

    Background Nonparametric item response theory (IRT) was used to examine (a) the performance of the 30 Positive and Negative Syndrome Scale (PANSS) items and their options ((levels of severity), (b) the effectiveness of various subscales to discriminate among differences in symptom severity, and (c) the development of an abbreviated PANSS (Mini-PANSS) based on IRT and a method to link scores to the original PANSS. Methods Baseline PANSS scores from 7,187 patients with Schizophrenia or Schizoaffective disorder who were enrolled between 1995 and 2005 in psychopharmacology trials were obtained. Option characteristic curves (OCCs) and Item Characteristic Curves (ICCs) were constructed to examine the probability of rating each of seven options within each of 30 PANSS items as a function of subscale severity, and summed-score linking was applied to items selected for the Mini-PANSS. Results The majority of items forming the Positive and Negative subscales (i.e. 19 items) performed very well and discriminate better along symptom severity compared to the General Psychopathology subscale. Six of the seven Positive Symptom items, six of the seven Negative Symptom items, and seven out of the 16 General Psychopathology items were retained for inclusion in the Mini-PANSS. Summed score linking and linear interpolation was able to produce a translation table for comparing total subscale scores of the Mini-PANSS to total subscale scores on the original PANSS. Results show scores on the subscales of the Mini-PANSS can be linked to scores on the original PANSS subscales, with very little bias. Conclusions The study demonstrated the utility of non-parametric IRT in examining the item properties of the PANSS and to allow selection of items for an abbreviated PANSS scale. The comparisons between the 30-item PANSS and the Mini-PANSS revealed that the shorter version is comparable to the 30-item PANSS, but when applying IRT, the Mini-PANSS is also a good indicator of illness severity

  12. Use of non-parametric item response theory to develop a shortened version of the Positive and Negative Syndrome Scale (PANSS).

    Science.gov (United States)

    Khan, Anzalee; Lewis, Charles; Lindenmayer, Jean-Pierre

    2011-11-16

    Nonparametric item response theory (IRT) was used to examine (a) the performance of the 30 Positive and Negative Syndrome Scale (PANSS) items and their options ((levels of severity), (b) the effectiveness of various subscales to discriminate among differences in symptom severity, and (c) the development of an abbreviated PANSS (Mini-PANSS) based on IRT and a method to link scores to the original PANSS. Baseline PANSS scores from 7,187 patients with Schizophrenia or Schizoaffective disorder who were enrolled between 1995 and 2005 in psychopharmacology trials were obtained. Option characteristic curves (OCCs) and Item Characteristic Curves (ICCs) were constructed to examine the probability of rating each of seven options within each of 30 PANSS items as a function of subscale severity, and summed-score linking was applied to items selected for the Mini-PANSS. The majority of items forming the Positive and Negative subscales (i.e. 19 items) performed very well and discriminate better along symptom severity compared to the General Psychopathology subscale. Six of the seven Positive Symptom items, six of the seven Negative Symptom items, and seven out of the 16 General Psychopathology items were retained for inclusion in the Mini-PANSS. Summed score linking and linear interpolation was able to produce a translation table for comparing total subscale scores of the Mini-PANSS to total subscale scores on the original PANSS. Results show scores on the subscales of the Mini-PANSS can be linked to scores on the original PANSS subscales, with very little bias. The study demonstrated the utility of non-parametric IRT in examining the item properties of the PANSS and to allow selection of items for an abbreviated PANSS scale. The comparisons between the 30-item PANSS and the Mini-PANSS revealed that the shorter version is comparable to the 30-item PANSS, but when applying IRT, the Mini-PANSS is also a good indicator of illness severity.

  13. Aspects of alcohol use disorder affecting social cognition as assessed using the Mini Social and Emotional Assessment (mini-SEA).

    Science.gov (United States)

    Cox, Sharon; Bertoux, Maxime; Turner, John J D; Moss, Antony; Locker, Kirsty; Riggs, Kevin

    2018-04-10

    Alcohol Use Disorder (AUD) is associated with problems with processing complex social scenarios. Little is known about the relationship between distinct AUD-related factors (e.g., years of problematic drinking), aspects of cognitive function and dysfunction in individuals diagnosed with AUD, and the relative impact these may have on social cognition. To explore differences in social cognition between a group of participants diagnosed with AUD and controls, using a clinical measure, the Mini Social and Emotional Assessment (mini-SEA). The mini-SEA was used to evaluate social and emotional understanding through a facial emotional recognition task and by utilising a series of social scenes some of which contain a faux pas (social error). Eighty-five participants (individuals with AUD and controls) completed demographic questions and a general cognitive and social cognitive test battery over three consecutive days. Between group analyses revealed that the participants with AUD performed less well on the faux pas test, and differences were also revealed in the emotional facial recognition task. Years of problematic alcohol consumption was the strongest predictor of poor ToM reasoning. These results suggest a strong link between AUD chronicity and social cognition, though the direction of this relationship needs further elucidation. This may be of clinical relevance to abstinence and relapse management, as basic social cognition skills and ability to maintain interpersonal relationships are likely to be crucial to recovery. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A positive diagnosis of functional (psychogenic) tics.

    Science.gov (United States)

    Demartini, B; Ricciardi, L; Parees, I; Ganos, C; Bhatia, K P; Edwards, M J

    2015-03-01

    Functional tics, also called psychogenic tics or pseudo-tics, are difficult to diagnose because of the lack of diagnostic criteria and their clinical similarities to organic tics. The aim of the present study was to report a case series of patients with documented functional tics and to describe their clinical characteristics, risk factors and psychiatric comorbidity. Also clinical tips are suggested which might help the differential diagnosis in clinical practice. Eleven patients (mean age at onset 37.2, SD 13.5; three females) were included with a documented or clinically established diagnosis of functional tics, according to consultant neurologists who have specific expertise in functional movement disorders or in tic disorders. Adult onset, absent family history of tics, inability to suppress the movements, lack of premonitory sensations, absence of pali-, echo- and copro-phenomena, presence of blocking tics, the lack of the typical rostrocaudal tic distribution and the coexistence of other functional movement disorders were common in our patients. Our data suggest that functional tics can be differentiated from organic tics on clinical grounds, although it is also accepted that this distinction can be difficult in certain cases. Clinical clues from history and examination described here might help to identify patients with functional tics. © 2014 EAN.

  15. Design considerations, architecture, and use of the Mini-Sentinel distributed data system.

    Science.gov (United States)

    Curtis, Lesley H; Weiner, Mark G; Boudreau, Denise M; Cooper, William O; Daniel, Gregory W; Nair, Vinit P; Raebel, Marsha A; Beaulieu, Nicolas U; Rosofsky, Robert; Woodworth, Tiffany S; Brown, Jeffrey S

    2012-01-01

    We describe the design, implementation, and use of a large, multiorganizational distributed database developed to support the Mini-Sentinel Pilot Program of the US Food and Drug Administration (FDA). As envisioned by the US FDA, this implementation will inform and facilitate the development of an active surveillance system for monitoring the safety of medical products (drugs, biologics, and devices) in the USA. A common data model was designed to address the priorities of the Mini-Sentinel Pilot and to leverage the experience and data of participating organizations and data partners. A review of existing common data models informed the process. Each participating organization designed a process to extract, transform, and load its source data, applying the common data model to create the Mini-Sentinel Distributed Database. Transformed data were characterized and evaluated using a series of programs developed centrally and executed locally by participating organizations. A secure communications portal was designed to facilitate queries of the Mini-Sentinel Distributed Database and transfer of confidential data, analytic tools were developed to facilitate rapid response to common questions, and distributed querying software was implemented to facilitate rapid querying of summary data. As of July 2011, information on 99,260,976 health plan members was included in the Mini-Sentinel Distributed Database. The database includes 316,009,067 person-years of observation time, with members contributing, on average, 27.0 months of observation time. All data partners have successfully executed distributed code and returned findings to the Mini-Sentinel Operations Center. This work demonstrates the feasibility of building a large, multiorganizational distributed data system in which organizations retain possession of their data that are used in an active surveillance system. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Mini-interfacial fracture toughness as a new validated enamel-bonding effectiveness test.

    Science.gov (United States)

    Pongprueksa, Pong; De Munck, Jan; Barreto, Bruno C; Karunratanakul, Kavin; Van Meerbeek, Bart

    2016-09-01

    Today׳s most commonly applied bonding effectiveness tests are criticized for their high variability and low reliability, the latter in particular with regard to measuring the actual strength of the adhesive interface. in continuation of previous research conducted at dentin, we hereby aimed to validate the novel mini-interfacial fracture toughness (mini-iFT) test on its applicability to assess bonding effectiveness of contemporary adhesives when bonded to enamel. The 3-step etch&rinse (E&R) adhesive OptiBond FL (Kerr), the 2-step self-etch (SE) adhesive Clearfil SE Bond (Kuraray Noritake) and the two multi-mode adhesives Clearfil S(3) Bond Plus (Kuraray Noritake) and Scotchbond Universal (3M ESPE), both used following a 2-step E&R and 1-step SE mode, were applied to clinically relevant, flattened enamel surfaces. A composite (Filtek Z100; 3M ESPE) build-up was made in layers. After 1-week water storage at 37°C, all specimens were sectioned perpendicular to the interface to obtain rectangular sticks. A mini-iFT notch was prepared at the adhesive-enamel interface using a thin diamond blade under water cooling. Finally, the specimens were loaded in a 4-point bending test until failure. the mini-iFT onto human enamel was significantly higher for the adhesives applied in E&R mode versus those applied in SE mode. The lowest mini-iFT was found for the adhesives applied following a 1-step SE approach. SEM fracture analysis revealed that all fractures originated at the adhesive-enamel interface and that the induced crack propagated preferentially along this interface. mini-iFT appeared a valid alternative method to assess the mechanical properties of adhesive-enamel interfaces. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Mini-Conference on the First Microns of the First Wall

    Energy Technology Data Exchange (ETDEWEB)

    Stotler, D. P.; Rognlien, T. D.; Krasheninnikov, S. I.

    2008-03-20

    Interactions between plasmas and their surrounding materials (plasma facing components) are of great interest to present and future magnetic fusion experiments, and ITER [ITER Physics Basis Editors, ITER Physics Exper Group Chairs, ITER Joint Central Team, and Physics Inte gration Unit, Nucl. Fusion 39, 2137 (1999)] in particular. This interest is the result of concerns with the survivability of these materials, as well as the impact of these interactions back on the plasma. These interactions begin on the surface, but can have consequences a few microns into the material.This mini-conference on these "first microns" was designed to bring to the Division of Plasma Physics Meeting experts on these topics who would otherwise not attend. At the same time, the mini-conference was intended to expose the broader fusion community to these issues. The mini-conference covered in three, half-day sessions the topics of lithium coatings and surfaces, mixed materials characteristics, and issues associated with graphite.

  18. Mini-Conference on the First Microns of the First Wall

    International Nuclear Information System (INIS)

    Stotler, D.P.; Rognlien, T.D.; Krasheninnikov, S.I.

    2008-01-01

    Interactions between plasmas and their surrounding materials (plasma facing components) are of great interest to present and future magnetic fusion experiments, and ITER (ITER Physics Basis Editors, ITER Physics Exper Group Chairs, ITER Joint Central Team, and Physics Integration Unit, Nucl. Fusion 39, 2137 (1999)) in particular. This interest is the result of concerns with the survivability of these materials, as well as the impact of these interactions back on the plasma. These interactions begin on the surface, but can have consequences a few microns into the material. This mini-conference on these 'first microns' was designed to bring to the Division of Plasma Physics Meeting experts on these topics who would otherwise not attend. At the same time, the mini-conference was intended to expose the broader fusion community to these issues. The mini-conference covered in three, half-day sessions the topics of lithium coatings and surfaces, mixed materials characteristics, and issues associated with graphite

  19. Correlation between the Mini Mental State Examination-Korean version and the Measurement of Quality of the Environment in the institutionalized elderly.

    Science.gov (United States)

    Kim, Myoung-Kwon; Kim, Tae Hoon; Kim, Seong-Gil

    2015-11-01

    [Purpose] This study aimed to investigate the correlation between the cognitive level of the elderly and their attitude towards the living environment. [Subjects and Methods] A total of 80 elderly people hospitalized in a nursing home in K city, South Korea, participated in this study. Pearson correlation analysis was used to test the relationships between scores on the Mini Mental State Examination-Korean Version and Measurement of Quality of the Environment (facilitators and obstacles). [Results] A positive and moderately strong correlation (r = 0.462) was found between scores on the Mini Mental State Examination and the Measurement of Quality of the Environment (obstacle). [Conclusion] In a nursing home, patients with relatively higher cognitive levels can perceive more obstacles in the surrounding environment.

  20. MiniWall Tool for Analyzing CFD and Wind Tunnel Large Data Sets

    Science.gov (United States)

    Schuh, Michael J.; Melton, John E.; Stremel, Paul M.

    2017-01-01

    It is challenging to review and assimilate large data sets created by Computational Fluid Dynamics (CFD) simulations and wind tunnel tests. Over the past 10 years, NASA Ames Research Center has developed and refined a software tool dubbed the MiniWall to increase productivity in reviewing and understanding large CFD-generated data sets. Under the recent NASA ERA project, the application of the tool expanded to enable rapid comparison of experimental and computational data. The MiniWall software is browser based so that it runs on any computer or device that can display a web page. It can also be used remotely and securely by using web server software such as the Apache HTTP server. The MiniWall software has recently been rewritten and enhanced to make it even easier for analysts to review large data sets and extract knowledge and understanding from these data sets. This paper describes the MiniWall software and demonstrates how the different features are used to review and assimilate large data sets.

  1. Calling all LEGO lovers! Add a mini control room to your collection

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    The mini LHC Lego project launched in March (see here) now has almost 6,000 supporters - well on its way to the 10,000 votes needed for it to (hopefully!) hit store shelves. This week, the project added a new feature to its line: a mini control centre! The new LEGO Control centre, featuring operators "Kerstin" and "Marco".   The mini LHC project is the brainchild of ATLAS PhD student Nathan Readioff, who designed Lego replicas of the LHC and the ALICE, ATLAS, CMS and LHCb experiments on a micro scale. Each detector model is small enough to fit in the palm of your hand but crammed with detailed internal systems revealed by cutaway walls. Every major detector component is represented by a Lego piece. Now, Nathan has created a control centre to complement the mini LHC project. This would be an add-on feature for Lego’s consideration, should they decide to develop the accelerator into a box set. “The control centre is ...

  2. Lateral forces exerted through ball or bar attachments in relation to the inclination of mini-implant underneath overdentures: in vitro study.

    Science.gov (United States)

    Takagaki, Kyozo; Gonda, Tomoya; Maeda, Yoshinobu

    2015-09-01

    Lateral force to mini-implants should be avoided because mini-implants are weak mechanically because of its small diameter. Overdentures retained by mini-implants are usually formed using ball attachments. However, bar attachments can offer the advantage of splinting the mini-implants. This study examined the effect of attachments in withstanding these lateral forces in tilted mini-implants of overdentures. Strain gauges were attached to the mini-implants (2.5 × 18 mm) embedded in an acrylic resin block. Two mini-implants were inserted vertically (Control) or with one mini-implant inclined at 10° or 20° (10-inclined and 20-inclined, respectively). The female portions of the attachments were secured to the denture base. A prefabricated ball attachment and CAD/CAM-fabricated bar attachment were compared. A vertical load of 49 N was applied to the occlusal surface at a distance 10 mm away from the center of two mini-implants. The lateral force borne by the mini-implants was measured via the attached strain gauge. Mann-Whitney U-test and an analysis of Bonferroni correction were used to compare differences between the two attachments and among the three models (P < 0.05). The lateral force exerted to the inclined mini-implant was significantly greater than that borne by a vertical mini-implant for both attachment types. The lateral force on the 20° inclined mini-implants with bar attachments was smaller than that on mini-implants with ball attachments. Inclined mini-implants are subjected to greater stresses than vertical ones, and a bar attachment can reduce the lateral forces borne by the mini-implant when one mini-implant inclined at 20°. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. The role of Entrepreneurial Universities in interfacing Competitive Advantages: The Case of Beira Interior region (Portugal)

    OpenAIRE

    Ferreira, Joao; Leitão, João; Raposo, Mario

    2006-01-01

    This paper reveals the importance of a local entrepreneurial university in interfacing competitive advantages, by assuming the condition of most influent and dynamic engine of regional development. The strategic diagnosis provides the identification of a dominant quadrant in the TOWS matrix application to the Beira Interior region, which is dominated by Mini-Maxi strategies. For improving the competitive positioning of that region, the transition from the dominant quadrant (Mini-Maxi) t...

  4. Ressources minières en Afrique : Quelle réglementation pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Ressources minières en Afrique : Quelle réglementation pour le développement ? Couverture du livre Ressources minières en Afrique : Quelle réglementation pour le développement ? Directeur(s):. Bonnie Campbell. Maison(s) d'édition: Presses de l'Université du Québec, CRDI. 6 juillet 2009. ISBN : 9782760525214.

  5. Error Correction of Meteorological Data Obtained with Mini-AWSs Based on Machine Learning

    Directory of Open Access Journals (Sweden)

    Ji-Hun Ha

    2018-01-01

    Full Text Available Severe weather events occur more frequently due to climate change; therefore, accurate weather forecasts are necessary, in addition to the development of numerical weather prediction (NWP of the past several decades. A method to improve the accuracy of weather forecasts based on NWP is the collection of more meteorological data by reducing the observation interval. However, in many areas, it is economically and locally difficult to collect observation data by installing automatic weather stations (AWSs. We developed a Mini-AWS, much smaller than AWSs, to complement the shortcomings of AWSs. The installation and maintenance costs of Mini-AWSs are lower than those of AWSs; Mini-AWSs have fewer spatial constraints with respect to the installation than AWSs. However, it is necessary to correct the data collected with Mini-AWSs because they might be affected by the external environment depending on the installation area. In this paper, we propose a novel error correction of atmospheric pressure data observed with a Mini-AWS based on machine learning. Using the proposed method, we obtained corrected atmospheric pressure data, reaching the standard of the World Meteorological Organization (WMO; ±0.1 hPa, and confirmed the potential of corrected atmospheric pressure data as an auxiliary resource for AWSs.

  6. Search for Sterile Neutrinos Using the MiniBooNE Beam

    Energy Technology Data Exchange (ETDEWEB)

    Sorel, Michel [Columbia Univ., New York, NY (United States)

    2005-01-01

    The possible existence of light sterile neutrinos in Nature is motivated, and the prospects to extend sterile neutrino searches beyond current limits is substantiated, using the MiniBooNE neutrino beam and detector at Fermilab. We report on the neutrino flux predictions for the MiniBooNE experiment, on the characterization of the charged-current, quasi-elastic interactions of muon neutrinos ({nu}{sub {mu}}n {yields} {mu}{sup -}p) observed, and on the experiment's sensitivity to sterile neutrinos via muon neutrino disappearance.

  7. Towards the theory of mini black holes with subplanckian mass

    International Nuclear Information System (INIS)

    Zeldovich, Y.B.

    1984-01-01

    This chapter phenomenologically examines the question of the decay (evaporation) and formation of mini black holes. Neutral black holes are considered, having neither electrical charge, nor color and weak charge, so that no long range vector field is present beyond gravitational radius. Topics considered include thermodynamic equilibrium and the formation of light black holes, the formation and decay of light black holes in the big bang, and the difficulties of the theory. It is emphasized that the existence of mini black holes has not yet been proven

  8. The ASTRI Mini-Array Science Case

    Science.gov (United States)

    Vercellone, Stefano; Catalano, O.; Maccarone, M.; Stamerra, A.; Di Pierro, F.; Vallania, P.; Canestrari, R.; Bonnoli, G.; Pareschi, G.; Tosti, G.; Caraveo, P.; ASTRI Collaboration

    2013-04-01

    ASTRI is a flagship project of the Italian Ministry of Education, University and Research. Within this framework, INAF is currently developing an end-to-end prototype of the CTA small-size telescope in a dual-mirror configuration (SST-2M) to be tested under field conditions, and scheduled to start data acquisition in 2014. A remarkable improvement in terms of performance could come from the operation, in 2016, of a SST-2M mini-array, composed by a few SST-2M telescopes and to be placed at final CTA Southern Site. The SST mini-array will be able to study in great detail relatively bright sources (a few x10E-12 erg/cm2/s at 10 TeV) with an angular resolution of a few arcmin and an energy resolution of about 10 - 15%. Moreover, thanks to the array approach, it will be possible to verify the wide FoV performance to detect very high energy showers with the core located at a distance up to 500 m, to compare the mini-array performance with the Monte Carlo expectations by means of deep observations of few selected targets, and to perform the first CTA science, with its first solid detections during the first year of operation. Prominent sources such as extreme blazars (1ES 0229+200), nearby well-known BL Lac objects (MKN 501) and radio-galaxies, galactic pulsar wind nebulae (Crab Nebula, Vela-X), supernovae remnants (Vela-junior, RX J1713.7-3946) and microquasars (LS 5039), as well as the Galactic Center can be observed in a previously unexplored energy range, in order to investigate the electron acceleration and cooling, relativistic and non relativistic shocks, the search for cosmic-ray (CR) Pevatrons, the study of the CR propagation, and the impact of the extragalactic background light on the spectra of the sources.

  9. Establishment and Efficiency Evaluation of a Simple Mini hatchery for production of Oreochromis niloticus (GIFT strain seeds

    Directory of Open Access Journals (Sweden)

    M.P.K.S.K. De Silva

    2015-06-01

    Full Text Available A simple technology mini hatchery was established for small scale farmers to meet their own GIFT seed requirements. Different shapes and sizes of jars were trialed for incubation of eggs and yolk-sac larvae. Concaved bottom round plastic bottles (4 L and rectangular (3 L plastic trays gave the best hatchability of eggs and survival of yolk-sac larvae respectively. The best stocking density was 500 eggs/larvae L-1. Optimised flow rate into the incubation bottles and rearing trays were 2.70±0.18 L min-1 and 5.40±0.14 L min-1 respectively. Two gravel filters (15 L and 20 L made with discarded and low cost material purified the water from the incubation containers and directed into a water recirculation system. Production efficiency of this mini hatchery was compared with a hapa breeding method. Two hapas having 10 m3 size and 1.6 mm mesh were positioned in an earthen pond. Each hapa was stocked with 40 GIFT broodfish at 1:1 female to male ratio. In Phase I of the study (60 days, eggs collected from Hapa I were placed in incubation bottles and hatchability and survival rate were determined. In parallel, free-swimming fry were collected and counted from the Hapa II at every 14 days. The study continued in the same way for Phase II (next 60 days by interchanging the brood fish between Hapa I and Hapa II. Yield from the mini hatchery (24,000 fry was significantly different (P≤0.05 from hapa method (4,879 fry indicating that this established mini hatchery could serve as a productive model to support small scale farmers in GIFT seed production.

  10. MINI-TRAC code: a driver program for assessment of constitutive equations of two-fluid model

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Abe, Yutaka; Ohnuki, Akira; Murao, Yoshio

    1991-05-01

    MINI-TRAC code, a driver program for assessment of constitutive equations of two-fluid model, has been developed to perform assessment and improvement of constitutive equations of two-fluid model widely and efficiently. The MINI-TRAC code uses one-dimensional conservation equations for mass, momentum and energy based on the two-fluid model. The code can work on a personal computer because it can be operated with a core memory size less than 640 KB. The MINI-TRAC code includes constitutive equations of TRAC-PF1/MOD1 code, TRAC-BF1 code and RELAP5/MOD2 code. The code is modulated so that one can easily change constitutive equations to perform a test calculation. This report is a manual of the MINI-TRAC code. The basic equations, numerics, constitutive, equations included in the MINI-TRAC code will be described. The user's manual such as input description will be presented. The program structure and contents of main variables will also be mentioned in this report. (author)

  11. A mini-exhibition with maximum content

    CERN Multimedia

    Laëtitia Pedroso

    2011-01-01

    The University of Budapest has been hosting a CERN mini-exhibition since 8 May. While smaller than the main travelling exhibition it has a number of major advantages: its compact design alleviates transport difficulties and makes it easier to find suitable venues in the Member States. Its content can be updated almost instantaneously and it will become even more interactive and high-tech as time goes by.   The exhibition on display in Budapest. The purpose of CERN's new mini-exhibition is to be more interactive and easier to install. Due to its size, the main travelling exhibition cannot be moved around quickly, which is why it stays in the same country for 4 to 6 months. But this means a long waiting list for the other Member States. To solve this problem, the Education Group has designed a new exhibition, which is smaller and thus easier to install. Smaller maybe, but no less rich in content, as the new exhibition conveys exactly the same messages as its larger counterpart. However, in the slimm...

  12. Use of the mini-MAC scale in the evaluation of mental adjustment to cancer.

    Science.gov (United States)

    Czerw, Aleksandra Izabela; Marek, Ewelina; Deptała, Andrzej

    2015-01-01

    The objective of the study was to evaluate mental adjustment to cancer in patients diagnosed with an oncologic disease through identification of the coping strategies they had adopted. Seventy-four patients of the Clinic of Oncology and Haematology at the Central Clinical Hospital (CSK) of the Ministry of Interior (MSW) in Warsaw were included in the study. The degree of adaptation to cancer was evaluated with the use of the mini-Mental Adjustment to Cancer (mini-MAC) scale. The individual subscales, i.e. fighting spirit, positive redefinition, helplessness-hopelessness, and anxious preoccupation, were collated with socio-demographic characteristics. Study findings indicate that: 1) tumour patients typically manifest behaviour that allows one to identify their adjustment to cancer; 2) in malignant tumour patients constructive behaviour prevails over destructive behaviour; 3) the helplessness-hopelessness response is more pronounced in men than women; 4) metastatic patients manifest stronger helplessness-hopelessness response than patients with locally limited tumours; 5) pensioners more often than people of working age adopt the helplessness-hopelessness strategy; and 6) patients with the shortest disease period manifest the strongest fighting spirit. Cancer patients employ various strategies of coping with disease depending on socio-demographic factors.

  13. Comparison of topical and infiltration anesthesia for orthodontic mini-implant placement

    Directory of Open Access Journals (Sweden)

    Matheus Miotello Valieri

    2014-04-01

    Full Text Available Objective: To compare the acceptability and effectiveness of topical and infiltration anesthesia for placement of mini-implants used as temporary anchorage devices. Methods: The sample comprised 40 patients, 17 males and 23 females, whose mean age was 26 years old and who were all undergoing orthodontic treatment and in need for anchorage reinforcement. Mini-implants were bilaterally placed in the maxilla of all individuals, with infiltration anesthesia on one side and topical anesthesia on the other. These 40 patients completed two questionnaires, one before and another after mini-implant placement and pain was measured through a visual analog scale (VAS. The data collected were analyzed using descriptive statistics and the measurements of pain were compared by means of the non-parametric test of Mann-Whitney. Results: It was found that 60% of patients felt more comfortable with the use of topical anesthesia for mini-implant placement; 72.5% of patients described the occurrence of pressure during placement of the anchorage device as the most unpleasant sensation of the entire process; 62.5% of patients felt more pain with the use of topical anesthesia. Conclusion: It was concluded that patients had less pain with the use of infiltration anesthesia, and also preferred this type of anesthetic.

  14. Investigation of a robust tendon-sheath mechanism for flexible membrane wing application in mini-UAV

    Science.gov (United States)

    Lee, Shian; Tjahjowidodo, Tegoeh; Lee, Hsuchew; Lai, Benedict

    2017-02-01

    Two inherent issues manifest themselves in flying mini-unmanned aerial vehicles (mini-UAV) in the dense area at tropical climate regions, namely disturbances from gusty winds and limited space for deployment tasks. Flexible membrane wing (FMW) UAVs are seen to be potentials to mitigate these problems. FMWs are adaptable to gusty airflow as the wings are able to flex according to the gust load to reduce the effective angle-of-attack, thus, reducing the aerodynamic loads on the wing. On the other hand, the flexible structure is allowing the UAV to fold in a compact package, and later on, the mini-UAV can be deployed instantly from the storage tube, e.g. through a catapult mechanism. This paper discusses the development of an FMW UAV actuated by a tendon-sheath mechanism (TSM). This approach allows the wing to morph to generate a rolling moment, while still allowing the wing to fold. Dynamic characteristics of the mechanism that exhibits the strong nonlinear phenomenon of friction on TSM are modeled and compensated for. A feed-forward controller was implemented based on the identified nonlinear behavior to control the warping position of the wing. The proposed strategy is validated experimentally in a wind tunnel facility by creating a gusty environment that is imitating a realistic gusty condition based upon the results of computational fluid dynamics (CFD) simulation. The results demonstrate a stable and robust wing-warping actuation, even in gusty conditions. Accurate wing-warping can be achieved via the TSM, while also allowing the wings to fold.

  15. Rapid assessment of tinnitus-related psychological distress using the Mini-TQ.

    Science.gov (United States)

    Hiller, Wolfgang; Goebel, Gerhard

    2004-01-01

    The aim of this study was to develop an abridged version of the Tinnitus Questionnaire (TQ) to be used as a quick tool for the assessment of tinnitus-related psychological distress. Data from 351 inpatients and 122 outpatients with chronic tinnitus were used to analyse item statistics and psychometric properties. Twelve items with an optimal combination of high item-total correlations, reliability and sensitivity in assessing changes were selected for the Mini-TQ. Correlation with the full TQ was >0.90, and test-retest reliability was 0.89. Validity was confirmed by associations with general psychological symptom patterns. Treatment effects indicated by the Mini-TQ were slightly greater than those indicated by the full TQ. The Mini-TQ is recommended as a psychometrically approved and solid tool for rapid and economical assessment of subjective tinnitus distress.

  16. Effect of gamma irradiation on nutrient digestibility in SPF mini-pig

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun-Yeob [College of Animal Life Sciences , Kangwon National University, 192-1 Kangwon Avenue 1, Chuncheon, Gangwon-do 200-701 (Korea, Republic of); Cho, Sung-Back [Swine Science Division, National Institute of Animal Science, Cheonan, Chungcheongnam-do 330-801 (Korea, Republic of); Kim, Yoo-Yong [College of Agriculture and Life Science, Seoul National University, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Ohh, Sang-Jip, E-mail: sjohh@kangwon.ac.k [College of Animal Life Sciences , Kangwon National University, 192-1 Kangwon Avenue 1, Chuncheon, Gangwon-do 200-701 (Korea, Republic of)

    2011-01-15

    This study was carried out to evaluate the effect of gamma irradiation on nutrient digestibility of either soy-based or milk-based diet for specific pathogen-free (SPF) mini-pigs. Gamma irradiation of the diets was done at dosage of 10 kGy with {sup 60}Co whereas autoclaving was executed at 121 {sup o}C for 20 min. Apparent crude protein digestibilities of gamma irradiated diets were higher (p<0.05) than those of autoclaved diets regardless of diet type. Digestibilities of dry matter, gross energy and total carbohydrate in the irradiated diet were higher than those of the autoclaved diet. From the results of nutrient digestibility of mini-pig diets in this study, 10 kGy gamma radiation was suggested as a convenient diet radicidation method that can minimize the decrease in nutrient digestibility on feeding to SPF mini-pigs.

  17. Incorporating Inquiry into Upper-Level Homework Assignments: The Mini-Journal

    Science.gov (United States)

    Whittington, A. G.; Speck, A. K.; Witzig, S. B.; Abell, S. K.

    2009-12-01

    The U.S. National Science Education Standards provide guidelines for teaching science through inquiry, where students actively develop their understanding of science by combining scientific knowledge with reasoning and thinking skills. Inquiry activities include reading scientific literature, generating hypotheses, designing and carrying out investigations, interpreting data, and formulating conclusions. Inquiry-based instruction emphasizes questions, evidence, and explanation, the essential features of inquiry. As part of an NSF-funded project, “CUES: Connecting Undergraduates to the Enterprise of Science,” new inquiry-based homework materials were developed for two upper-level classes at the University of Missouri: Geochemistry (required for Geology majors), and Solar System Science (open to seniors and graduate students, co-taught and cross-listed between Geology and Physics & Astronomy). We engage students in inquiry-based learning by presenting homework exercises as “mini-journal” articles that follow the format of a scientific journal article, including a title, authors, abstract, introduction, methods, results, discussion and citations to peer-reviewed literature. The mini-journal provides a scaffold and serves as a springboard for students to develop and carry out their own follow-up investigation. They then present their findings in the form of their own mini-journal. Mini-journals replace traditional homework problem sets with a format that more directly reflects and encourages scientific practice. Students are engaged in inquiry-based homework which encompass doing, thinking, and communicating, while the minijournal allows the instructor to contain lines of inquiry within the limits posed by available resources. In the examples we present, research is conducted via spreadsheet modeling, where the students develop their own spreadsheets. The key differences between the old and new formats include (i) the active participation of the students in

  18. Advances in Autonomous Mini Robots : Proceedings of the 6-th AMiRE Symposium

    CERN Document Server

    Joaquin, Sitte; Felix, Werner

    2012-01-01

    Autonomous robots must carry out useful tasks all by themselves relying entirely on their own perceptions of their environment. The cognitive abilities required for autonomous action are largely independent of robot size, which makes mini robots attractive as artefacts for research, education and entertainment. Autonomous mini robots must be small enough for experimentation on a desktop or a small laboratory.  They must be easy to carry and safe for interaction with humans. They must not be expensive. Mini robot designers have to work at the leading edge of technology so that their creations can carry out purposeful autonomic action under these constraints. Since 2001 researchers have met every two years for an international symposium to report on the advances achieved in Autonomous Mini  Robots for Research and Edutainment (AMiRE). The AMiRE Symposium is a single track conference that offers ample opportunities for discussion and exchange of ideas. This volume contains the contributed papers of the 2011 AM...

  19. Mini-Uav LIDAR for Power Line Inspection

    Science.gov (United States)

    Teng, G. E.; Zhou, M.; Li, C. R.; Wu, H. H.; Li, W.; Meng, F. R.; Zhou, C. C.; Ma, L.

    2017-09-01

    Light detection and ranging (LIDAR) system based on unmanned aerial vehicles (UAVs) recently are in rapid advancement, meanwhile portable and flexible mini-UAV-borne laser scanners have been a hot research field, especially for the complex terrain survey in the mountains and other areas. This study proposes a power line inspection system solution based on mini-UAV-borne LIDAR system-AOEagle, developed by Academy of Opto-Electronics, Chinese Academy of Sciences, which mounted on a Multi-rotor unmanned aerial vehicle for complex terrain survey according to real test. Furthermore, the point cloud data was explored to validate its applicability for power line inspection, in terms of corridor and line laser point clouds; deformation detection of power towers, etc. The feasibility and advantages of AOEagle have been demonstrated by the promising results based on the real-measured data in the field of power line inspection.

  20. Mini MAX-DOAS Measurements of Air Pollutants over China

    Science.gov (United States)

    Staadt, Steffen; Hao, Nan; Trautmann, Thomas

    2016-08-01

    This study continues the work of Clémer et al., (2010) and is aimed to improve trace gas retrievals with mini MAX-DOAS measurements in Nanjing. Based on that work, aerosol extinction vertical profiles are retrieved using the bePRO inversion algorithm developed by the Royal Belgian Institute for Space Aeronomy (BIRA- IASB). Afterwards, the tropospheric trace gas vertical profiles and vertical column densities (VCDs) are retrieved by applying the optimal estimation method to the O4 MAX-DOAS measurements. The Profiles for N O2 , S O2 , glyoxal, formaldehyde and nitrous acid are obtained with different results and different settings for the DOAS measurement. The AODs show small positive correlation against the AERONET values. For NO2, the retrieval shows reasonable concentrations in winter as opposed to summer and has small positive correlations with GOME-2 data. The SO2 VCDs are not correlated with the GOME-2 data, due to high uncertainties from MAX-DOAS and satellite retrievals, while the vertical mixing ratios (VMR) show good agreement with in-situ data (SORPES) at Nanjing. Nitrous acid shows a maximum in winter and a minimum in summer, while glyoxal has its maximum in August and September.

  1. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Celha Borges Costa Alves

    Full Text Available ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm, Neodent(tm and SIN(tm were separately immersed in artificial saliva (pH 6.76 for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM. The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. Results: No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm, Neodent(tm and SIN(tm present high corrosion resistance and are not cytotoxic.

  2. Upside-down stomach – results of mini-invasive surgical therapy

    Directory of Open Access Journals (Sweden)

    Cestmir Neoral

    2011-12-01

    Full Text Available Aim: The authors evaluate the results of mini-invasive therapy in patients diagnosed with upside-down stomach. Material and methods: From 1998 to 2008, a total of 27 patients diagnosed with upside-down stomach were surgicallytreated at the 1st Department of Surgery, University Hospital Olomouc. Before the operation, patients wereexamined endoscopically and a barium swallow was performed. In all 27 patients (100%, the operation was performedelectively laparoscopically. The principle of the operation in all cases was reposition of the stomach into theabdominal cavity, resection of the hernial sac and hiatoplasty. In addition, in 15 patients (56% with reflux symptomsor endoscopic findings of reflux oesophagitis, fundoplication in Nissen’s modification was also performed. Fundopexywas indicated in 12 patients (44%. Results: In all patients (100%, the operation was performed mini-invasively; conversion to an open procedure wasnever necessary. In 3 cases (11%, the left pleural cavity was opened during the operation; this was treated by introducinga chest drain. The operation mortality in the patient set was zero; morbidity was 11%. A year after the operation,patients were re-examined, and follow-up endoscopy and barium swallow were performed. Conclusions: In all patients diagnosed with upside-down stomach, surgical treatment is indicated due to the risk ofdeveloping severe complications. Mini-invasive surgical therapy in the hands of an experienced surgeon is a safe procedurewhich offers patients all the benefits of mini-invasive therapy with promising short- and long-term results.

  3. Positive predictive value and impact of misdiagnosis of a heart failure diagnosis in administrative registers among patients admitted to a University Hospital cardiac care unit

    DEFF Research Database (Denmark)

    Mard, Shan; Nielsen, Finn Erland

    2010-01-01

    To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF.......To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF....

  4. Mini Seminar on Form Filling Ability of Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2005-01-01

    The Nordic mini-seminar “Form Filling Ability of Self-Compacting Concrete” took place on 3-4 November 2003 at the Danish Technological Institute in Taastrup, Denmark. The mini-seminar gathered 12 participants from Finland, Sweden, Norway and Denmark. The objective was to present and discuss recent...... developments of Self-Compacting Concrete in the Nordic countries. In general, the seminar included results and observations on the effect of fresh concrete behaviour, casting technique, and organisation on site on the filling ability, passing ability, and surface quality. The seminar had participants from...

  5. Development of the Thai version of Mini-Cog, a brief cognitive screening test.

    Science.gov (United States)

    Trongsakul, Supaporn; Lambert, Rod; Clark, Allan; Wongpakaran, Nahathai; Cross, Jane

    2015-05-01

    Cognitive impairment, such as dementia, has emerged as the leading public health problem among the elderly. Therefore, early detection of the disorder and providing appropriate healthcare and management is important, particularly, for the patients with comorbid diabetes who require long-term treatment strategies. In Thailand, because of a large number of elderly patients with diabetes, and time constraints in primary care settings, a short and effective cognitive screening test is required. The Mini-Cog is a short and valid cognitive screening test that was specifically designed for use in primary care settings. The present study translated the English language version into a Thai language version, and then measured the interrater reliability and concurrent validity. The processes of cross-language translation were carried out to develop a Thai language version of the Mini-Cog. A total of 21 Thai older adults with type 2 diabetes with a mean aged of 69 ± 7 years were recruited into a study investigating the interrater reliability and concurrent validity of the Mini-Cog Thai version in one primary care center in Thailand. The Mini-Cog Thai version showed a good interrater reliability (K = 0.80, P validity (r = 0.47, P = 0.007, 95% CI 0.37,0.55) with the Mini-Mental State Examination Thai 2002. The findings show that the Thai version of the Mini-Cog is a reliable, performance-based tool in the screening for cognitive function in primary care settings in Thailand. It is recommended that it could be used as a new cognitive screening test for the aging population in the Thai community. © 2014 Japan Geriatrics Society.

  6. DIAGNOSIS OF FINANCIAL POSITION STRUCTURE

    Directory of Open Access Journals (Sweden)

    CĂRUNTU GENU ALEXANDRU

    2017-02-01

    Full Text Available The analysis of financial position structure aimed at issues that highlight on the one hand the economic relations between asset side and liability side and on the other hand the changes that are achieved as a result of internal and external factors. In order to establish the causes that led over time to changing the structure of financial position we analyze the structure of assets, liabilities and equity. The balance sheet is a summary representing only a snapshot at a certain time that changes continuously and through which are presented economic goods, rights and obligations of the company at year-end. The balance sheet is the universal working tool that contains information on the company's heritage and performance. To achieve its purpose, namely to generate profit in conditions of intense competition the firm constitutes a heritage structure, an economic fixed and circulating capital appropriate to future needs.

  7. The reliability, validity, and applicability of an English language version of the Mini-ICF-APP.

    Science.gov (United States)

    Molodynski, Andrew; Linden, Michael; Juckel, George; Yeeles, Ksenija; Anderson, Catriona; Vazquez-Montes, Maria; Burns, Tom

    2013-08-01

    This study aimed at establishing the validity and reliability of an English language version of the Mini-ICF-APP. One hundred and five patients under the care of secondary mental health care services were assessed using the Mini-ICF-APP and several well-established measures of functioning and symptom severity. 47 (45 %) patients were interviewed on two occasions to ascertain test-retest reliability and 50 (48 %) were interviewed by two researchers simultaneously to determine the instrument's inter-rater reliability. Occupational and sick leave status were also recorded to assess construct validity. The Mini-ICF-APP was found to have substantial internal consistency (Chronbach's α 0.869-0.912) and all 13 items correlated highly with the total score. Analysis also showed that the Mini-ICF-APP had good test-retest (ICC 0.832) and inter-rater (ICC 0.886) reliability. No statistically significant association with length of sick leave was found, but the unemployed scored higher on the Mini ICF-APP than those in employment (mean 18.4, SD 9.1 vs. 9.4, SD 6.4, p Mini-ICF-APP correlated highly with the other measures of illness severity and functioning considered in the study. The English version of the Mini-ICF-APP is a reliable and valid measure of disorders of capacity as defined by the International Classification of Functioning. Further work is necessary to establish whether the scale could be divided into sub scales which would allow the instrument to more sensitively measure an individual's specific impairments.

  8. Risk of Recurrence or Contralateral Breast Cancer More than 5 Years After Diagnosis of Hormone Receptor-Positive Early-Stage Breast Cancer.

    Science.gov (United States)

    Wilson, Sheridan; Speers, Caroline; Tyldesley, Scott; Chia, Stephen; Kennecke, Hagen; Ellard, Susan; Lohrisch, Caroline

    2016-08-01

    Three large studies have shown a survival benefit from 10 years of adjuvant hormone therapy (AHT). We evaluated the risk of an event 5 years after the initial breast cancer (BC) diagnosis and identified the prognostic factors to assist clinicians considering extended AHT. Patients newly referred to the BC Cancer Agency with stage I to III estrogen receptor-positive BC diagnosed from 1989 to 2004 who had undergone AHT were identified by the BC Cancer Agency's Breast Cancer Outcomes Unit. Cases with recurrence, death, or contralateral BC occurring within the first 5 years were excluded. The 10-year event-free survival (EFS) and 95% confidence intervals (CIs) were calculated using the Kaplan-Meier method. This provided estimates of recurrence risk after the fifth year following the diagnosis. The histopathologic and age variables were examined for prognostic value by univariate analysis. Within our cohort, 6615 women were postmenopausal and 1886 were premenopausal at the BC diagnosis. The median follow-up period was 11 years. The 10-year EFS for women aged cancer (any grade) and for stage II (node-negative and node-positive), grade I cancer. Our data have identified BCs associated with a very low recurrence risk 5 to 10 years after diagnosis, providing women with such cancers confidence about a decision to discontinue AHT after 5 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Introducing a Low-Cost Mini-Uav for - and Multispectral-Imaging

    Science.gov (United States)

    Bendig, J.; Bolten, A.; Bareth, G.

    2012-07-01

    The trend to minimize electronic devices also accounts for Unmanned Airborne Vehicles (UAVs) as well as for sensor technologies and imaging devices. Consequently, it is not surprising that UAVs are already part of our daily life and the current pace of development will increase civil applications. A well known and already wide spread example is the so called flying video game based on Parrot's AR.Drone which is remotely controlled by an iPod, iPhone, or iPad (http://ardrone.parrot.com). The latter can be considered as a low-weight and low-cost Mini-UAV. In this contribution a Mini-UAV is considered to weigh less than 5 kg and is being able to carry 0.2 kg to 1.5 kg of sensor payload. While up to now Mini-UAVs like Parrot's AR.Drone are mainly equipped with RGB cameras for videotaping or imaging, the development of such carriage systems clearly also goes to multi-sensor platforms like the ones introduced for larger UAVs (5 to 20 kg) by Jaakkolla et al. (2010) for forestry applications or by Berni et al. (2009) for agricultural applications. The problem when designing a Mini-UAV for multi-sensor imaging is the limitation of payload of up to 1.5 kg and a total weight of the whole system below 5 kg. Consequently, the Mini-UAV without sensors but including navigation system and GPS sensors must weigh less than 3.5 kg. A Mini-UAV system with these characteristics is HiSystems' MK-Okto (www.mikrokopter.de). Total weight including battery without sensors is less than 2.5 kg. Payload of a MK-Okto is approx. 1 kg and maximum speed is around 30 km/h. The MK-Okto can be operated up to a wind speed of less than 19 km/h which corresponds to Beaufort scale number 3 for wind speed. In our study, the MK-Okto is equipped with a handheld low-weight NEC F30IS thermal imaging system. The F30IS which was developed for veterinary applications, covers 8 to 13 μm, weighs only 300 g, and is capturing the temperature range between -20 °C and 100 °C. Flying at a height of 100 m, the camera

  10. Mini vs standard percutaneous nephrolithotomy for renal stones: a comparative study.

    Science.gov (United States)

    ElSheemy, Mohammed S; Elmarakbi, Akram A; Hytham, Mohammed; Ibrahim, Hamdy; Khadgi, Sanjay; Al-Kandari, Ahmed M

    2018-03-16

    To compare the outcome of mini-percutaneous nephrolithotomy (Mini-PNL) versus standard-PNL for renal stones. Retrospective study was performed between March 2010 and May 2013 for patients treated by Mini-PNL or standard-PNL through 18 and 30 Fr tracts, respectively, using pneumatic lithotripsy. Semirigid ureteroscope (8.5/11.5 Fr) was used for Mini-PNL and 24 Fr nephroscope for standard-PNL. Both groups were compared in stone free rate(SFR), complications and operative time using Student-t, Mann-Whitney, Chi square or Fisher's exact tests as appropriate in addition to logistic regression analysis. P PNL (378) and standard-PNL (151) were nearly comparable in patients and stones criteria including stone burden (3.77 ± 2.21 vs 3.77 ± 2.43 cm 2 ; respectively). There was no significant difference in number of tracts or supracostal puncture. Mini-PNL had longer operative time (68.6 ± 29.09 vs 60.49 ± 11.38 min; p = 0.434), significantly shorter hospital stay (2.43 ± 1.46 vs 4.29 ± 1.28 days) and significantly higher rate of tubeless PNL (75.1 vs 4.6%). Complications were significantly higher in standard-PNL (7.9 vs 20.5%; p PNL (89.9 vs 96%; p = 0.022). This significant difference was found with multiple stones and large stone burden (> 2 cm 2 ), but the SFR was comparable between both groups with single stone or stone burden ≤ 2 cm. Logistic regression analysis confirmed significantly higher complications and SFR with standard-PNL but with significantly shorter operative time. Mini-PNL has significantly lower SFR when compared to standard-PNL (but clinically comparable) with markedly reduced complications and hospital stay. Most of cases can be performed tubeless. The significant difference in SFR was found with multiple stones or large stone burden (> 2 cm 2 ), but not with single stones or stone burden ≤ 2 cm 2 .

  11. Playing Around in the Solar System: Mini-games for Many Missions

    Science.gov (United States)

    Fisher, D. K.; Leon, N.; Fitzpatrick, A. J.; Wessen, A.

    2010-12-01

    Several NASA solar system missions will have major milestones during 2011, the Year of the Solar System. These events include launches, encounters, and orbit insertions. Other missions will continue the explorations already underway. The “Year of the Solar System Game” on The Space Place website (http://spaceplace.nasa.gov/en/kids/solar-system) brings all these efforts together in the context of the whole solar system. The game helps to build awareness of the characteristics of our solar system and some of the missions that are continuing to advance our knowledge and understanding. It is one of many educational tools being developed and deployed for the Year of the Solar System. The game is a “super-game” that encompasses a number of mission-related “mini-games.” The mini-games can be played individually, and they all contribute toward achievements in the super-game. The enveloping interface for all the games is an animated solar system. The player clicks on a planet or a moon, sees a close-up image, and reads a short paragraph about the object. If the object has been endowed with a mission mini-game, player can click on the tiny spacecraft, read about the mission, then play the game—or, if impatient, just immediately play the game (and read about the mission later, we hope). A score “page” keeps track of the player’s achievements and scores. Players earn achievements by reading about the planets, moons, asteroids, comets, and missions and by playing the mission mini-games. The game targets upper elementary age children, as does the entire Space Place website. Each mini-game, although simple, incorporates elements of the spacecrafts’ missions and their target objects. For example, in Cassini Commander, the player must navigate the Cassini spacecraft through gaps in Saturn’s rings and around Saturn’s moons. The super-game is designed to accommodate any number of mission mini-games, so we are hoping to continue to add missions and increase

  12. Disclosure of diagnosis of multiple sclerosis in the workplace positively affects employment status and job tenure.

    Science.gov (United States)

    Kirk-Brown, A K; Van Dijk, P A; Simmons, R D; Bourne, M P; Cooper, B K

    2014-06-01

    For many employees with multiple sclerosis (MS), disclosure of their diagnosis at work is seen as a high-risk strategy that might lead to diminished perceptions of their capabilities by supervisors and colleagues, if not outright discrimination. The consequence of this mistrust surrounding the disclosure process is that employees with MS may leave it until too late to effectively manage symptoms at work. The objective of this paper is to statistically evaluate the relationship between disclosure of diagnosis at work and maintenance of employment. Three annual, large-sample self-report surveys of MS patients prospectively examined the relationship between disclosure of diagnosis at work and employment status. A total of 1438 people responded to all three surveys. Of employed persons in 2010 (n = 946), 673 also responded to the 2012 survey. Of these 673 respondents 564 were still employed. People who had disclosed their MS status to an employer were more likely to remain in employment in Year 3. The effect of disclosure in predicting employment status remained after controlling for age, gender, hours worked and level of disability. This study provides the first empirical support for the positive role of disclosure in maintaining employment status, measured both as job retention and tenure in current employment. © The Author(s) 2013.

  13. Development of a brief version of the Social Phobia Inventory using item response theory: the Mini-SPIN-R.

    Science.gov (United States)

    Aderka, Idan M; Pollack, Mark H; Simon, Naomi M; Smits, Jasper A J; Van Ameringen, Michael; Stein, Murray B; Hofmann, Stefan G

    2013-12-01

    The Social Phobia Inventory (SPIN) is a widely used measure in mental health settings and a 3-item version (mini-SPIN) has been developed as a screening instrument for social anxiety disorder. In the present study, we examined the psychometric properties of the SPIN and developed a brief version (mini-SPIN-R) designed to assess social anxiety severity using item response theory. Our sample included 569 individuals with social anxiety disorder who participated in 2 clinical trials and filled out a battery of self-report measures. Using a nonparametric kernel smoothing method we identified the most sensitive items of the SPIN. These 3 items comprised the mini-SPIN-R, which was found to have greater internal consistency, and to capture a greater range of symptoms compared to the mini-SPIN. The mini-SPIN-R evidenced superior convergent validity compared to the mini-SPIN and both measures had similar divergent validity. Thus, the mini-SPIN-R is a promising brief measure of social anxiety severity. Copyright © 2013. Published by Elsevier Ltd.

  14. Mini-weather shelters: statistical analysis for comparison and evaluation of efficiency

    Directory of Open Access Journals (Sweden)

    Sérgio Serafini Júnior

    2014-04-01

    Full Text Available In the context of the disciplines of climatology of the Department of Geography of University of Sao Paulo, site investigations allow students to practice climatologic analysis using electronic sensors installed in meteorological mini-shelters, designed by tutors and post graduate students. Based on the models of meteorological mini-shelters described as Tarifa (TAR, Abrigo de Baixo Custo (ABC [Shelter of Low Cost] e Quatro Águas(4AS [Four Waters], this research made a comparative analysis of registered data, using as reference the Automatic Meteorological Station installed on the premises of the Geography building. The efficiency data from these mini-shelters demonstrated that, although all presented different results in relation to the Automatic Meteorological Station (EMA, they also presented a performance very satisfactory around 80% of all sampled period, allowing the achievement of good results for use in academic and technical work.

  15. Typing of canine parvovirus isolates using mini-sequencing based single nucleotide polymorphism analysis.

    Science.gov (United States)

    Naidu, Hariprasad; Subramanian, B Mohana; Chinchkar, Shankar Ramchandra; Sriraman, Rajan; Rana, Samir Kumar; Srinivasan, V A

    2012-05-01

    The antigenic types of canine parvovirus (CPV) are defined based on differences in the amino acids of the major capsid protein VP2. Type specificity is conferred by a limited number of amino acid changes and in particular by few nucleotide substitutions. PCR based methods are not particularly suitable for typing circulating variants which differ in a few specific nucleotide substitutions. Assays for determining SNPs can detect efficiently nucleotide substitutions and can thus be adapted to identify CPV types. In the present study, CPV typing was performed by single nucleotide extension using the mini-sequencing technique. A mini-sequencing signature was established for all the four CPV types (CPV2, 2a, 2b and 2c) and feline panleukopenia virus. The CPV typing using the mini-sequencing reaction was performed for 13 CPV field isolates and the two vaccine strains available in our repository. All the isolates had been typed earlier by full-length sequencing of the VP2 gene. The typing results obtained from mini-sequencing matched completely with that of sequencing. Typing could be achieved with less than 100 copies of standard plasmid DNA constructs or ≤10¹ FAID₅₀ of virus by mini-sequencing technique. The technique was also efficient for detecting multiple types in mixed infections. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Development of a Mini-Freeze Dryer for Material-Sparing Laboratory Processing with Representative Product Temperature History.

    Science.gov (United States)

    Obeidat, Wasfy M; Sahni, Ekneet; Kessler, William; Pikal, Michael

    2018-02-01

    The goal of the work described in this publication was to evaluate a new, small, material-sparing freeze dryer, denoted as the "mini-freeze dryer or mini-FD", capable of reproducing the product temperature history of larger freeze dryers, thereby facilitating scale-up. The mini-FD wall temperatures can be controlled to mimic loading procedures and dryer process characteristics of larger dryers. The mini-FD is equipped with a tunable diode laser absorption spectroscopy (TDLAS) water vapor mass flow monitor and with other advanced process analytical technology (PAT) sensors. Drying experiments were performed to demonstrate scalability to larger freeze dryers, including the determination of vial heat transfer coefficients, K v . Product temperature histories during K v runs were evaluated and compared with those obtained with a commercial laboratory-scale freeze dryer (LyoStar II) for sucrose and mannitol product formulations. When the mini-FD wall temperature was set at the LyoStar II band temperature (- 20°C) to mimic lab dryer edge vials, edge vial drying in the mini-FD possessed an average K v within 5% of those obtained during drying in the LyoStar II. When the wall temperature of the mini-FD was set equal to the central vial product temperature, edge vials behaved as center vials, possessing a K v value within 5% of those measured in the LyoStar II. During both K v runs and complete product freeze drying runs, the temperature-time profiles for the average edge vials and central vial in the mini-FD agreed well with the average edge and average central vials of the LyoStar II.

  17. THE X-RAY PROPERTIES OF THE OPTICALLY BRIGHTEST MINI-BAL QUASARS FROM THE SLOAN DIGITAL SKY SURVEY

    International Nuclear Information System (INIS)

    Wu Jianfeng; Brandt, W. N.; Comins, M. L.; Garmire, Gordon P.; Schneider, Donald P.; Gibson, Robert R.; Shemmer, Ohad

    2010-01-01

    We have compiled a sample of 14 of the optically brightest radio-quiet quasars (m i ≤ 17.5 and z ≥ 1.9) in the Sloan Digital Sky Survey Data Release 5 quasar catalog that have C IV mini-broad absorption lines (mini-BALs) present in their spectra. X-ray data for 12 of the objects were obtained via a Chandra snapshot survey using ACIS-S, while data for the other two quasars were obtained from archival XMM-Newton observations. Joint X-ray spectral analysis shows that the mini-BAL quasars have a similar average power-law photon index (Γ ∼ 1.9) and level of intrinsic absorption (N H ∼ 21 cm -2 ) as non-BMB (neither BAL nor mini-BAL) quasars. Mini-BAL quasars are more similar to non-BMB quasars than to BAL quasars in their distribution of relative X-ray brightness (assessed with Δα ox ). Relative colors indicate mild dust reddening in the optical spectra of mini-BAL quasars. Significant correlations between Δα ox and UV absorption properties are confirmed for a sample of 56 sources combining mini-BAL and BAL quasars with high signal-to-noise ratio rest-frame UV spectra, which generally supports models in which X-ray absorption is important in enabling driving of the UV absorption-line wind. We also propose alternative parameterizations of the UV absorption properties of mini-BAL and BAL quasars, which may better describe the broad absorption troughs in some respects.

  18. Mäo kolmnurka kerkib mini-Eesti / Rein Sikk

    Index Scriptorium Estoniae

    Sikk, Rein, 1961-

    2010-01-01

    Järvamaale Mäo kolmnurka kavandatavast Eestimaad vähendatuna näitavast teemapargist mini-Eesti, mis peaks valmima 2014. aastaks. Kavandatavast Narva vanalinna rekonstruktsioonist maketina, mis peaks tulema umber 200 korda 400 meetri suurune

  19. Mini-grid for sustainable integrated coastal development

    International Nuclear Information System (INIS)

    Bala, B.K.; Islam, M.M.

    2005-01-01

    Power grid cannot reach everywhere. Yet there are alternatives. Renewable energy can offer an ideal source of electricity for the communities far from a grid- on an island, or other isolated situations. Design and economics of a solar-diesel hybrid mini-grid system for 132 families in an isolated island-Sandwip are presented. The electrical load is considered based on the local needs and the electrical load demand is 20 kWh. The sizing of the hybrid system consists of 31 solar modules, 10 number of 24 V batteries, 2 Inverters having a total capacity of 24 kW, 24 V DC/220 V AC. A diesel generator set of 10 kW capacity is selected for back up during shortfall. The life cycle cost (LCC) is estimated and LCC is found to be Tk.15.51 / kWh compared to electricity price of Tk.4.00/kWh. Finally, the sustainability of solar-diesel hybrid mini-grid for an isolated island -Sandwip is discussed. (author)

  20. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review.

    Science.gov (United States)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2015-04-02

    Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of OMIs may provide a more accurate and immediate diagnosis of implant-root contact (target condition) than radiographic imaging (reference standard). An accurate index test could reduce or eliminate X-ray exposure. These issues, the common use of OMIs, the high prevalence of the target condition, and because most OMIs are placed between roots warrant a systematic review. We will assess 1) the diagnostic accuracy and the adverse effects of the index test, 2) whether OMIs with root contact have higher insertion torque values than those without, and 3) whether intermediate torque values have clinical diagnostic utility. The Preferred Reporting Items for Systematic review and Meta-Analysis Protocols (PRISMA-P) 2015 statement was used as a the guideline for reporting this protocol. Inserting implants deliberately into dental roots of human participants would not be approved by ethical review boards and adverse effects of interventions are generally underreported. We will therefore apply broad spectrum eligibility criteria, which will include clinical, animal and cadaver models. Not including these models could slow down knowledge translation. Both randomized and non-randomized research studies will be included. Comparisons of interest and subgroups are pre-specified. We will conduct searches in MEDLINE and more than 40 other electronic databases. We will search the grey literature and reference lists and hand-search ten journals. All methodological procedures will be conducted by three reviewers. Study selection, data extraction and analyses, and protocols for contacting authors and resolving conflicts between reviewers are described. Designed specific risk of bias tools will be tailored

  1. Mini clinical evaluation exercise in undergraduate dermatovenereology education: an experience of University of Pamukkale, Medical Faculty

    Directory of Open Access Journals (Sweden)

    Şeniz Ergin

    2013-03-01

    Full Text Available Background and Design: Mini Clinical Evaluation Exercise (Mini-CEX is being widely used in medical education and is a reliable and valid method for the assessment of residents’ competency in medical interviewing, physical examination, humanistic qualities/professionalism, clinical judgment, counseling skills, organization, and efficiency. In order to enhance formative evaluation methods in our faculty, we planned to apply the method to students on dermatovenereology training. Materials and Methods: The Mini-CEX was performed by residents to 42 medical students. At first, 5 residents were evaluated by a faculty member with Mini-CEX and were informed about their application-oriented evaluator roles. The students were informed prior to conducting the assessment. Standard Mini-CEX form was used for the assessment. The participants were rated in 7 competencies and each was rated using a 9-point Likert scale. At the end of each encounter, students and evaluators rated their satisfaction with Mini-CEX using a 9-point Likert scale. Student’s t-test and one-way ANOVA were used for statistical analysis. Student feedback was evaluated with “grounded theory”. Results: A total of 50 assessments, 44 in outpatient and 6 in inpatient clinic, were performed. Satisfaction with the Mini-CEX was rated by the evaluators and the students as 7,16 and 7,98, respectively. There was no significant difference between the evaluators in terms of student satisfaction. Average time spent on observing the encounter and in giving feedback was 16.5 and 6.5 minutes, respectively. There was no significant difference between assessors in terms of time spent observing and giving feedback. Average scores of assessed clinical competencies were between 4,28 and 8,14. The highest scores were reported on humanistic qualities/ professionalism whereas the lowest were reported on clinical judgment skills. Discussion: According to our data, we believe that Mini-CEX may be used as an

  2. Iranian Version of the Mini-Mental Adjustment to Cancer Scale: Factor Structure and Psychometric Properties.

    Science.gov (United States)

    Patoo, Mozhgan; Allahyari, Abbas Ali; Moradi, Ali Reza; Payandeh, Mehrdad

    2015-01-01

    Mental adjustment to cancer is known as a psychological, physical, and psychological health variable among cancer patients. The present study examines the factor structure and psychometric properties of the Mini-Mental Adjustment to Cancer scale (Mini-MAC) in a sample of Iranian adults who suffer from cancer. The sample consists of 320 cancer patients selected through non-random convenient sampling procedure from the hospitals and clinics in the cities of Kermanshah and Shiraz in Iran, using the Mini-MAC scale. One hundred of these patients also completed the Hospital Anxiety and Depression scale. Statistical methods used to analyze the data included confirmatory and exploratory factor analysis, discriminate validity, and Cronbach alpha coefficients for internal consistency. Factor analysis confirms five factors in the Mini-MAC. The values of fit indices are within the acceptable range. Significant correlations between the Mini-MAC and other measures also show that this scale has discriminate validity. Alpha coefficients for the subscales are Helplessness/Hopelessness,.94; Cognitive Avoidance.76; Anxious Preoccupation,.90; Fatalism,.77; Fighting Spirit.80; and total scale.84, respectively. The results confirm the five-factor structure of the Persian Mini-MAC scale and also prove that it is a reliable and valid scale. They show that this scale has sufficient power to measure different aspects of mental adjustment in patients with cancer.

  3. Research on fault diagnosis of nuclear power plants based on genetic algorithms and fuzzy logic

    International Nuclear Information System (INIS)

    Zhou Yangping; Zhao Bingquan

    2001-01-01

    Based on genetic algorithms and fuzzy logic and using expert knowledge, mini-knowledge tree model and standard signals from simulator, a new fuzzy-genetic method is developed to fault diagnosis in nuclear power plants. A new replacement method of genetic algorithms is adopted. Fuzzy logic is used to calculate the fitness of the strings in genetic algorithms. Experiments on the simulator show it can deal with the uncertainty and the fuzzy factor

  4. Evaluation of mechanical strengths of three types of mini-implants in artificial bones

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Tseng

    2017-02-01

    Full Text Available We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini-implants. Thirty mini-implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0×12 mm, Type B (stainless steel, 2.0×12 mm, and Type C (titanium alloy, 2.0×11 mm.The mini-implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT, resonance frequency (RF, and removal torque (RT] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively. In the 45° test, the RFs of Type C (9.2 kHz was significantly higher than those of Type A (7.0 kHz and Type B (6.7 kHz. The anchor area of the mini-implants was in the order of Type C (706 mm2>Type B (648 mm2>Type A (621 mm2. Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT among the three types of mini-implants. The anchor area plays a crucial role in the mechanical strength of mini-implants.

  5. Evaluation of mechanical strengths of three types of mini-implants in artificial bones.

    Science.gov (United States)

    Tseng, Yu-Chuan; Wu, Ju-Hui; Ting, Chun-Chan; Chen, Hong-Sen; Chen, Chun-Ming

    2017-02-01

    We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini-implants. Thirty mini-implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0×12 mm), Type B (stainless steel, 2.0×12 mm), and Type C (titanium alloy, 2.0×11 mm).The mini-implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT), resonance frequency (RF), and removal torque (RT)] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively) were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively). In the 45° test, the RFs of Type C (9.2 kHz) was significantly higher than those of Type A (7.0 kHz) and Type B (6.7 kHz). The anchor area of the mini-implants was in the order of Type C (706 mm 2 )>Type B (648 mm 2 )>Type A (621 mm 2 ). Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT) among the three types of mini-implants. The anchor area plays a crucial role in the mechanical strength of mini-implants. Copyright © 2016. Published by Elsevier Taiwan.

  6. Analisis Sumber dan Penggunaan Modal Kerja pada Mini Market Pelangi Jambi

    OpenAIRE

    Sopini, Pupu; Trifani, Chairani Yuli

    2017-01-01

    The working capital having nature of flexible, big or small working capital can be added or reduced in accordance with need company. Control working capital that will exactly ensure of continuity the operations firm efficien and economical. The objective of analyze sources and use working capital to how working capital used. Research objectives: 1) to know the sources and the use of capital work At Mini Market Pelangi Period 2012-2016. 2) to analyze the use of capital work At Mini Market Pel...

  7. Trends in diagnosis and control of bovine mastitis: a review.

    Science.gov (United States)

    Deb, Rajib; Kumar, Amit; Chakraborty, Sandip; Verma, Amit Kumar; Tiwari, Ruchi; Dhama, Kuldeep; Singh, Umesh; Kumar, Sushil

    2013-12-01

    Mastitis (inflammation of mammary gland) is a most devastating disease condition in terms of economic losses occurring throughout the world. The etiological agents may vary from place to place depending on climate; animal species and animal husbandry and include wide variety of gram positive and gram negative bacteria; and fungi. They may be either contagious viz. Staphylococcus aureus; Streptococcus agalactiae or environmental viz. S. dysgalactiae, S. uberis, Corynebacterium bovis and Coagulase negative Staphylococcus. Conventional diagnostic tests viz. California Mastitis Test (CMT); R-mastitest and Mast-O-test methods are applied under field conditions; whereas somatic cell count and Bulk Tank Somatic Cell Count (BTSCC) are useful for early mastitis detection and detection of sub clinical or chronic mastitis respectively. In vitro culture based diagnosis require further study as they can detect only viable cells. The advent of Polymerase Chain Reaction (PCR) technology along with its various versions like multiplex and real time PCR has improved the rapidity and sensitivity of diagnosis. Circulating micro RNA (miRNA) based diagnosis; immune assay and proteomics based detection along with biochips and biosensors prove to be asset to diagnosticians for advanced diagnosis of this economically important condition. Improvement of milking hygiene; implementation of post-milking teat disinfection; regular control of the milking equipments; implementation of milking order; Improvement of bedding material are the general measures to prevent new cases of mastitis. The use of antibiotics (intramammary infusions; bacteriocins) and herbs (Terminalia spp.) are important for prophylaxis and therapeutics. Vaccines viz. cell based; Recombinant (staphylococcal enterotoxin type C mutant) or chimeric (pauA); live (S. uberis 0140J stain based) and bacterial surface extract based; DNA-based and DNA-protein based have greatly aided in management of bovine mastitis. Quorum sensing and

  8. STORAGE TIME EFFECT ON MINI-CUTTINGS ROOTING IN Tectona grandis LINN F. CLONES

    Directory of Open Access Journals (Sweden)

    Yorleny Badilla

    2017-08-01

    Full Text Available ABSTRACT The study aimed to evaluate the influence of storage length on Tectona grandis mini-cuttings survival and rooting. A factorial arrangement (4 x 7 was utilized, based on four clones (Carapá, Ipê, GU5 and TB7 and seven time intervals from mini-cuttings harvesting until final sowing (0, 1, 2, 4, 8, 12 and 16 hours. A randomized block design with three replicates and 16 mini-cuttings per experimental unit was utilized. Survival and rooting rates were evaluated after greenhouse culture (30 days after sowing and after shadow house culture (40 days after sowing; as well as height, collar diameter, aerial and root biomass 55 days after sowing. No significant differences were observed in survival and rooting rates among time intervals in teak mini-cuttings preparation from these four clones. However differences among clones were registered for rooting rate, suggesting a genotypic effect. Survival and rooting rates were very high after greenhouse culture (93% and 90% respectively, as well as survival after culture in a shadow-house (88%.

  9. Comparison of shoulder positions at MR arthrography: change of labroligamentous complex shape and diagnosis of labral tears

    International Nuclear Information System (INIS)

    Kwak, Jin Young; Ha, Doo Hoe; Kim, Jeung Sook; Lee, Young Soo

    2001-01-01

    To compare the neutral, internal, and external rotation positions of the glenohumeral joint during magnetic resonance (MR) arthrography performed to assess changes in the shape of the labroligamentous complex (LLC) and in the labral tear. MR arthrography of the shoulder was retrospectively evaluated in 36 patients aged 14-66 (mean, 40) years. Fourteen cases were confirmed by arthroscopic surgery (7 SLAP lesions, 2 Bankart lesions, 1 both SLAP and Bankart lesions). Axial fat-suppressed T1-weighted spin-echo images were acquired with each shoulder in the neutral position, and with internal and external rotations. In each position, we measured the angle of rotation between the perpendicular line on the glenoid fossa and the long axis of the humeral head, analyzing the relationship between the rotational angle and changes in the shape of the LLC at each internal and external rotation, relative to the neutral position. In addition, labral tears in 14 arthroscopically confirmed joints were evaluated in each position. Mean angles of rotation relative to the neutral position were 44.1 and 45.3 degrees in internal and external rotation, respectively. Changes in the anterior LLC occurred in 25 and 24 cases of internal and external rotation, respectively. There was a significantly meaningful relationship between rotational angle and changes in the shape of the anterior LLC during external rotation, and when this changes was noticed, the rotational angle was wider (p<0.05). The posterior LLC changed in shape in 13 and 16 cases of internal and external rotation, respectively, but changes according to the angle of rotation were not statistically significant. In arthroscopically confirmed joints, diagnosis of the eight SLAP lesions at external rotation tended to become more accurate, but no statistically significant differences were noted (p=0.07). Two Bankart lesions were interpreted as a tear in all three positions, and one other such lesion was interpreted as a tear in the

  10. Mini Project Programming Exams

    DEFF Research Database (Denmark)

    Nørmark, Kurt; Thomsen, Lone Leth; Torp, Kristian

    2008-01-01

    A number of different types of final programming exams used or considered at the Department of Computer Science, Aalborg University, are identified and analyzed. Based on this analysis, a new type of programming exam is introduced called a Mini Project Programming (MIP) exam. MIP is a group...... years. The MIP exam is a compromise between (1) a long problem-based project exam and (2) a short oral or written programming exam. It is concluded that the strengths of MIP are the high degree of realism in the exam assignment and comprehensiveness relative to the course syllabus. The main challenge...

  11. Design of the MiniSLAR system for Bruce A

    International Nuclear Information System (INIS)

    Gray, M.G.

    1995-01-01

    Cancellation of Bruce A Retube created the need to perform SLAR on Unit 1. The existing SLAR system cannot reach Unit 1 and alternative systems had limitations. The concept and design of MiniSLAR were driven by the availability of existing components made for Retube. The MiniSLAR concept was developed by a team with members representing operators, technicians, and designers from various departments within Ontario Hydro and GE Canada. Overall project leadership was provided by Bruce A Projects and Modifications Department with assistance from Ontario Hydro Nuclear Technology Services. The responsibility for detailed design was assigned by Ontario Hydro to GE Canada. The detailed design proceeded with continual input and review by the team. The MiniSLAR delivery machine consists of a closure removal ram, a shield plug removal ram and a SLAR tool delivery ram attached to the sliding plate of a horizontal indexing mechanism. The moving plate is constrained by guide rails to a fixed plate and seals against it with o-rings. A snout and clamping mechanism mounts on the front of the fixed plate. The machine mounts atop a work table which provides the various motions required for endfitting engagement. Some operations are performed manually while others are remote and automatic. (author)

  12. Use of mini dental implants in ectodermal dysplasia children: follow-up of three cases.

    Science.gov (United States)

    Sfeir, E; Nassif, N; Moukarzel, C

    2014-07-01

    Ectodermal dysplasia is a hereditary genodermatosis characterised by a congenital defect of ectodermal structures, causing tooth malformations and anomalies. Implantology has become accepted in these subjects. However cases are often complicated by a reduction in the size of the alveolar process, making the insertion of conventional implants difficult without bone grafting. The reduced diameter of mini-implants and their ease of insertion provide an interesting solution in supporting removable or fixed prosthesis. The purpose of this paper is to report the follow-up of three cases of children (11-12 year- old) with ectodermal dysplasia in which mini-implants were used to support the prostheses. In the first case, two mini-implants were inserted into the anterior part of the mandible for stabilising a removable denture (2 years follow-up). In the other two cases, mini- implants were inserted in the maxilla and mandible to replace missing front teeth with fixed prostheses. Patients were called for follow- up every 6 months: in the sencod case follow-up lasted 4 years in the mandible and 2 years in the maxilla; in the third case, 2 years in the maxilla and 1 year in the mandible. The use of mini-implants in children with ectodermal dysplasia can enhance aesthetics, and functional and psychosocial development.

  13. Mini-column assay for rapid detection of malachite green in fish.

    Science.gov (United States)

    Shalaby, Ali R; Emam, Wafaa H; Anwar, Mervat M

    2017-07-01

    A simple, rapid and economical mini-column method for detecting malachite green (MG) residue in fish was developed. The method used a column with 2mm ID that was tightly packed with silica gel followed by alumina. Detection of MG was performed by viewing the developed mini-column at visible light by naked eye; where MG was seen as compact green band at the confluence of the silica gel layer with alumina layer. The limit of detection of the assay was 2ng which conform the minimum required performance limit (MRPL). Evaluation utility of the method indicated that all blank and spiked samples at levels below MRPL were assessed as accepted. The intensity of the green band increased whenever MG level in the extract increased; indicated that suggested mini-column technique could be used for semi-quantitative determination of MG in fish samples. The method can be used to select the questionable samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Mini-batch optimized full waveform inversion with geological constrained gradient filtering

    Science.gov (United States)

    Yang, Hui; Jia, Junxiong; Wu, Bangyu; Gao, Jinghuai

    2018-05-01

    High computation cost and generating solutions without geological sense have hindered the wide application of Full Waveform Inversion (FWI). Source encoding technique is a way to dramatically reduce the cost of FWI but subject to fix-spread acquisition setup requirement and slow convergence for the suppression of cross-talk. Traditionally, gradient regularization or preconditioning is applied to mitigate the ill-posedness. An isotropic smoothing filter applied on gradients generally gives non-geological inversion results, and could also introduce artifacts. In this work, we propose to address both the efficiency and ill-posedness of FWI by a geological constrained mini-batch gradient optimization method. The mini-batch gradient descent optimization is adopted to reduce the computation time by choosing a subset of entire shots for each iteration. By jointly applying the structure-oriented smoothing to the mini-batch gradient, the inversion converges faster and gives results with more geological meaning. Stylized Marmousi model is used to show the performance of the proposed method on realistic synthetic model.

  15. A simple and versatile mini-arc plasma source for nanocrystal synthesis

    International Nuclear Information System (INIS)

    Chen Junhong; Lu Ganhua; Zhu Liying; Flagan, Richard C.

    2007-01-01

    Nanocrystals in the lower-nanometer-size range are attracting growing interest due to their unique properties. A simple and versatile atmospheric direct current mini-arc plasma source has been developed to produce nanoparticles as small as a few nanometers. The nanoparticles are formed by direct vaporization of solid precursors followed by a rapid quenching. Both semiconductor tin oxide and metallic silver nanoparticles have been produced at rates of 1-10 mg/h using the mini-arc source. Transmission electron microscopy and X-ray diffraction analyses indicate that most nanoparticles as produced are nonagglomerated and crystalline. Size distributions of nanoparticles measured with an online scanning electrical mobility spectrometer are broader than the self-preserving distribution, suggesting that the nanoparticle growth is coagulation-dominated, and that the particles experience a range of residence times. The electrical charges carried by as-produced aerosol nanoparticles facilitate the manipulation of nanoparticles. The new mini-arc plasma source hence shows promise to accelerate the exploration of nanostructured materials

  16. Mini-laparotomic Colpotomy for a Cervicovaginal Leiomyoma: Preservation of hymenal integrity

    Directory of Open Access Journals (Sweden)

    Ibrahim Yalçin

    2016-03-01

    Full Text Available Background: Leiomyomas are the most common benign tumors of the uterus. Removal of the prolapsed pedunculated submucous myoma represents a distinct entity. Evaluation and treatment of such cases may need intervention via the hymen.Mini-laparotomic management of a pedunculated submucous myoma while preserving hymen integrity in a virginal patient is described as a safe alternative.. Case: A 30-year old, nulliparous virgin woman admitted to the outpatient- clinic with the complaint of irregular menstrual bleeding ongoing for three months. Pelvic ultrasound revealed a 5×6 cm solid mass in the cervico-vaginal location that filled the vaginal margins. Due to the patient’s consistent desire for preserving hymenal integrity, mini-laparotomic colpotomy was performed and the mass was removed successfully. Conclusion: Mini-laparotomic colpotomy, preserving hymen integrity, provides excellent visualization and it is a convenient and effective tool in the management of a cervicovaginal pedunculated submucous myoma

  17. Coherence between institutions and technologies - The case of mini hydropower in Switzerland

    OpenAIRE

    Crettenand, Nicolas

    2009-01-01

    Switzerland, with the forecasted electricity gap between domestic production and demand, aims to significantly increase renewable energy sources including hydropower. Mini hydropower (below 1MW) currently has considerable unused technical potential. As a renewable energy source (RES) it can contribute to climate change mitigation. CO2-taxes or emission trading systems (ETS) for planned thermal power plants could help facilitate mini hydropower (MHP). The technology is mature, but requires ade...

  18. An investigation of customer satisfaction and loyalty in projects of mini-hotels

    OpenAIRE

    Левыкин, Виктор Макарович; Дэвон, Валерия Викторовна

    2015-01-01

    The hospitality industry continues to evolve and improve in terms of Ukrainian realities of political and economic instability; managers of mini-hotels are experiencing difficulties with the implementation of repeat sales, increasing the number of loyal customers and the preservation of loyal customers, maintaining a high level of consumer loyalty and customer satisfaction.The article reveals the concept of satisfaction and loyalty of mini-hotels customers. It is schematically represented the...

  19. Marginal ulcers after one anastomosis (mini) gastric bypass: a survey of surgeons.

    Science.gov (United States)

    Mahawar, K K; Reed, A N; Graham, Y N H

    2017-06-01

    Many surgeons believe that one anastomosis (mini) gastric bypass (OAGB/MGB) is associated with a high marginal ulcer (MU) rate and that this is associated with complications in a significant number of patients. The purpose of this survey was to find out the participant-reported incidence of MU after OAGB/MGB and its complications. We also aimed to understand practices in this cohort concerning prophylaxis, diagnosis, treatment and management of complications. Bariatric surgeons who perform OAGB/MGB procedures were invited to participate in a confidential, online survey using SurveyMonkey®. A total of 86 surgeons performing OAGB/MGB procedures participated in the survey. The total number of OAGB/MGB procedures reported was 27 672, revealing 622 MU, giving an MU rate of 2.24 %. Most participants (69/84, 82.4%) routinely use proton pump inhibitor (PPI) prophylaxis, but there was variation in drugs, dosages and duration. The majority (49/85, 57.6%) of participants 'always' use endoscopy for diagnosis, and 48.1% (39/81) 'always' perform an endoscopy to ensure healing. Most (49/55) perforated ulcers were treated with laparoscopic repair +/- omentoplasty +/- drainage. Most (55/59, 93.0%) of the bleeding ulcers were managed with PPI +/- blood transfusions +/- endoscopic intervention (23/59, 39.0%). Non-healing ulcers were treated by conversion to Roux-en-Y gastric bypass (RYGB) in 46.5% of patients (n = 20/43). The participants did not report any MU-related mortality but described a number of risk factors for it. This survey is the first detailed attempt to understand the incidence of MU following OAGB/MGB; its complications; and practices concerning prophylaxis, diagnosis, treatment and management of complications. © 2017 World Obesity Federation.

  20. 'Mini'-Roadmapping - Ensuring Timely Sites' Cleanup/Closure by Resolving Science and Technology Issues

    International Nuclear Information System (INIS)

    Luke, D.E.; Dixon, B.W.; Murphy, J.A.

    2003-01-01

    Roadmapping is a powerful tool to manage technical risks and opportunities associated with complex problems. Roadmapping identifies technical capabilities required for both project- and program-level efforts and provides the basis for plans that ensure the necessary enabling activities will be done when needed. Roadmapping reveals where to focus further development of the path forward by evaluating uncertainties for levels of complexity, impacts, and/or the potential for large payback. Roadmaps can be customized to the application, a ''graded approach'' if you will. Some roadmaps are less detailed. We have called these less detailed, top-level roadmaps ''mini-roadmaps''. These mini roadmaps are created to tie the needed enablers (e.g., technologies, decisions, etc.) to the functions. If it is found during the mini-roadmapping that areas of significant risk exist, then those can be roadmapped further to a lower level of detail. Otherwise, the mini-roadmap may be sufficient to manage the project/program risk. Applying a graded approach to the roadmapping can help keep the costs down. Experience has indicated that it is best to do mini-roadmapping first and then evaluate the risky areas to determine whether to further evaluate those areas. Roadmapping can be especially useful for programs/projects that have participants from multiple sites, programs, or other entities which are involved. Increased synergy, better communications, and increased cooperation are the results from roadmapping a program/project with these conditions

  1. Afrontamiento del cáncer: adaptación al español y validación del Mini-MAC en población colombiana

    Directory of Open Access Journals (Sweden)

    Juan Pablo Román Calderón

    2015-08-01

    Full Text Available Objective: To examine the psychometric properties of the Spanish version of the Mini-MAC in a Colombian cancer sample. Methods: one hundred and twenty-six cancer patients completed the adapted Mini-MAC, the Hospital Anxiety and Depression Scale (HADS and the Detection of Emotional Distress Scale (DED. Descriptive, correlational and internal consistency statistics were obtained. An Principal Component Analysis (PCA and a Path Analysis using Structural Equation Modeling (SEM were performed. Results: A 4-factor solution was derived: Helplessness/Hopelessness (HH, Anxious Preoccupation (AP, Cognitive Avoidance (CA and Fighting Spirit (FS. PCA values indicated a factor solution explaining 58.9% of the variance. Significant correlations were found between HH and AP, and HH and FS. CA significantly correlated with AP and FS. Significant correlations between Mini-MAC, HADS and DED were found. Cronbach´s Alpha was superior to .6 in all cases. SEM analysis indicated that HH and AP have a positive effect on anxiety and a negative one on the emotional state, explaining 49% of the variance. CA had a negative effect on the emotional state. Altogether, HH, AP y CA explained 39% of the variance on emotional state. Conclusion: The Colombian version of the Mini-MAC is valid and reliable. It constitutes an adequate tool for assessment of coping in cancer.

  2. Development of mini VSAT system

    Science.gov (United States)

    Lu, Shyue-Ching; Chiu, Wu-Jhy; Lin, Hen-Dao; Shih, Mu-Piao

    1992-03-01

    This paper presents the mini VSAT (very small aperture terminal) system, which is a low cost networking system providing economical alternatives to the business world's datacom needs. The system is designed to achieve the highest possible performance/price ratio for private VSAT networks that range from a few tens of remote terminals to large networks of several thousands remote terminals. The paper describes the system architecture, major features, hardware and software structure, access protocol and performance of the developed system.

  3. Recent advances in preimplantation genetic diagnosis and screening.

    Science.gov (United States)

    Lu, Lina; Lv, Bo; Huang, Kevin; Xue, Zhigang; Zhu, Xianmin; Fan, Guoping

    2016-09-01

    Preimplantation genetic diagnosis/screening (PGD/PGS) aims to help couples lower the risks of transmitting genetic defects to their offspring, implantation failure, and/or miscarriage during in vitro fertilization (IVF) cycles. However, it is still being debated with regard to the practicality and diagnostic accuracy of PGD/PGS due to the concern of invasive biopsy and the potential mosaicism of embryos. Recently, several non-invasive and high-throughput assays have been developed to help overcome the challenges encountered in the conventional invasive biopsy and low-throughput analysis in PGD/PGS. In this mini-review, we will summarize the recent progresses of these new methods for PGD/PGS and discuss their potential applications in IVF clinics.

  4. [Necessity of repeated roll test in horizontal semicircular canalithasis positioned diagnosis].

    Science.gov (United States)

    Lu, H H; Zhao, Y; Chen, T S; Xu, K X; Wang, W; Liu, Q; Wen, C; Li, S S; Li, X J; Han, X; Lin, P

    2016-04-07

    To investigate the influence of repeated roll test in horizontal semicircular canalithasis(HSC-Can) positioned diagnosis, so as to investigate the cecessity of repeated roll test. The patients with a chief complaint of positional vertigo accepted two consecutive cycles roll test, the evoked nystagmus characteristics of each cycle recorded by video-nystagmuograph(VNG), whose direction, intensity, time and other parameters characteristics were analyzed in 51 HSC-Can. Horizontal nystagmus in the same direction with turning were induced in HSC-Can roll test. In 51 HSC-Can, roll test cycle 1 and cycle 2 induced nystagmus same strength side in 26 cases(51.0%), of which 19 cases with stronger nystagmus intensity in cycle 2, another 7 cases were weaker; the opposite strength side of the two loops induced nystagmus, and cycle 1 evoked nystagmus intensity were weaker than cycle 2, based on cycle 2 results determined HSC-Can affected side in 25 cases (49.0%). Lesion and normal side in cycle 1 induced nystagmus duration (x±s, the same below) were (13.4±11.5)s and (14.1±9.9)s, respectively intensity (18.1±22.4)°/s and (13.0±12.0)°/s; as in cycle 2 induced nystagmus duration was (20.7±10.2)s and (18.0±12.0)s, strength respectively(40.4±28.0)°/s and (15.6 ±11.2)°/s. Cycle 2 ipsilateral rotor position evoked nystagmus showed longer duration and stronger intensity than cycle 1. Between two cycle induced ipsilateral nystagmus duration, intensity differences were statistically significant (t values were -4.233 and -5.154, P=0.000). 51 HSC-Can patients, 44 patients selected repositioning maneuver, after 1-2 times of maneuver, 41 cases (93.2%) showed complete resolution of symptoms, all cases's symptoms were improved; other 7 patients selected medication only. The proposed suspicious HSC-Can patients should receive at least two cycles roll test, and mainly in the second cycle could determine the location of the responsible semicircular canals.

  5. Elaboration of mini plates with U-Mo for irradiation in a high flux reactor

    International Nuclear Information System (INIS)

    Pasqualini, Enrique E.

    2005-01-01

    Full text: International new efforts for the reconversion of HEU in research, testing and radioisotopes production reactors, have greatly incremented U-Mo fuels qualification activities. These qualifications require the resolution of undesired interaction at high fluxes between UMo particles and the aluminum matrix in the case of dispersed fuels and the development of U-Mo monolithic fuels. These efforts are being manifested in the planning and execution of additional series of irradiation tests of mini plates and full size plates. Recently, CNEA has elaborated mini plates with different proposals for the irradiation at the ATR reactor (250 MWTH, maximum thermal neutron flux 10 15 n.cm -2 .seg -1 ) at Idaho National Laboratory, USA. Uranium 7% (w/w) molybdenum (U-7Mo) particles were coated with silicon. Chemical vapour deposition (CVD) of silane and high temperature diffusion of silicon were used. Hydrided, milled and dehydrated (HMD) particles heat treated at 1000 C degrees during four hours and centrifugal atomized powder were coated and the results compared. Mini plates were elaborated with both kinds of particles. Mini plates were also elaborated with U-7Mo and silicon particles dispersed in the aluminium matrix. Monolithic mini plates were also developed by co lamination of U-7Mo with a Zircaloy-4 cladding. The different steps of this process are detailed and the method is shown to be versatile, can be easily scaled up and is performed with small modifications of usual equipment in fuel plants. The irradiation experiment is called RERTR-7A, includes a total of 32 mini plates and it is planed to finalize by mid 2006. (author) [es

  6. Long-term efficacy of a mini-course in radiation-reducing techniques in invasive cardiology

    International Nuclear Information System (INIS)

    Kuon, E.; Empen, K.; Hummel, A.; Doerr, M.; Reffelmann, T.; Felix, S.B.; Weitmann, K.; Hoffmann, W.; Staudt, A.

    2013-01-01

    Purpose: To validate the long-term efficacy of a 90-min. educational mini-course in less-irradiating cardiac interventional techniques. Materials and Methods: Before, two months after, and two years after the mini-course (periods I, II, and III), we analyzed the following radiation dose parameters for ten coronary angiographies (CA), performed by each of 7 cardiologists: total dose-area product (DAP), radiographic and fluoroscopic DAP fractions, number of radiographic frames and runs, and fluoroscopy time. Results: The median patient DAP for periods I, II and III was 31.4, 15.8 and 8.5 Gy x cm 2 , respectively. The long-term effect was related to shorter median fluoroscopy times (180, 172, and 120 s), shorter (57, 52, and 45) and fewer (12, 12, and 10) radiographic runs, consistent collimation and restriction to an adequate image quality. Both radiographic DAP/frame (28.7, 17.0, and 18.4 mGy x cm 2 ) and fluoroscopic DAP/second (45.7, 24.2, and 10.0 mGy x cm 2 ) decreased significantly. The multivariate linear regression analysis confirmed the increasing efficacy of the mini-course itself (-44.6 and -60.7 %), and revealed a decreasing influence of the interventionalist's experience (-8.6 % and -4.9 % per 1,000 CAs, lifelong performed until the mini-course). The number of CAs performed after the mini-course did not influence the long-term DAP results. Conclusion: The presented educational mini-course allows a significant, long-lasting, and apparently ongoing reduction of patient radiation exposure due to CA. A self-surveillant documentation of relevant radiation parameters is well suited to monitor and improve each operator's individual long-term radiation-reducing efforts. (orig.)

  7. Preliminary study on weapon grade uranium utilization in molten salt reactor miniFUJI

    International Nuclear Information System (INIS)

    Aji, Indarta Kuncoro; Waris, A.

    2014-01-01

    Preliminary study on weapon grade uranium utilization in 25MWth and 50MWth of miniFUJI MSR (molten salt reactor) has been carried out. In this study, a very high enriched uranium that we called weapon grade uranium has been employed in UF 4 composition. The 235 U enrichment is 90 - 95 %. The results show that the 25MWth miniFUJI MSR can get its criticality condition for 1.56 %, 1.76%, and 1.96% of UF 4 with 235 U enrichment of at least 93%, 90%, and 90%, respectively. In contrast, the 50 MWth miniFUJI reactor can be critical for 1.96% of UF 4 with 235 U enrichment of at smallest amount 95%. The neutron spectra are almost similar for each power output

  8. Early hemi-diaphragmatic plication through a video assisted mini-thoracotomy in postcardiotomy phrenic nerve paresis

    Science.gov (United States)

    Tsakiridis, Kosmas; Visouli, Aikaterini N.; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos

    2012-01-01

    New symptom onset of respiratory distress without other cause, and new hemi-diaphragmatic elevation on chest radiography postcardiotomy, are usually adequate for the diagnosis of phrenic nerve paresis. The symptom severity varies (asymptomatic state to severe respiratory failure) depending on the degree of the lesion (paresis vs. paralysis), the laterality (unilateral or bilateral), the age, and the co-morbidity (respiratory, cardiac disease, morbid obesity, etc). Surgical treatment (hemi-diaphragmatic plication) is indicated only in the presence of symptoms. The established surgical treatment is plication of the affected hemidiaphragm which is generally considered safe and effective. Several techniques and approaches are employed for diaphragmatic plication (thoracotomy, video-assisted thoracoscopic surgery, video-assisted mini-thoracotomy, laparoscopic surgery). The timing of surgery depends on the severity and the progression of symptoms. In infants and young children with postcardiotomy phrenic nerve paresis the clinical status is usually severe (failure to wean from mechanical ventilation), and early plication is indicated. Adults with postcardiotomy phrenic nerve paresis usually suffer from chronic dyspnoea, and, in the absence of respiratory distress, conservative treatment is recommended for 6 months -2 years, since improvement is often observed. Nevertheless, earlier surgical treatment may be indicated in non-resolving respiratory failure. We present early (25th day postcardiotomy) right hemi-diaphragm plication, through a video assisted mini-thoracotomy in a high risk patient with postcardiotomy phrenic nerve paresis and respiratory distress. Early surgery with minimal surgical trauma, short operative time, minimal blood loss and postoperative pain, led to fast rehabilitation and avoidance of prolonged hospitalization complications. The relevant literature is discussed. PMID:23304442

  9. ANALISIS KEMUNCULAN KETERAMPILAN SPESIFIK LAB MIKROBIOLOGI MELALUI PEMBELAJARAN MIKROBIOLOGI BERBASIS PROYEK INKUIRI “MINI-RISET” MAHASISWA BIOLOGI

    Directory of Open Access Journals (Sweden)

    Mr Kusnadi

    2012-01-01

    Full Text Available Telah dilakukan penelitian untuk menganalisis kemunculan keterampilan laboratorium mikrobiologi melalui program pembelajaran mikrobiologi berbasis proyek inkuiri (P2MBPI mini-riset. Penelitian melibatkan sejumlah mahasiswa semester IV Program Studi Biologi di salah satu LPTK Negeri di kota Bandung (n=33, yang mengikuti perkuliahan mikrobiologi. Program pembelajaran dirancang dalam setting laboratorium berbasis proyek inkuiri kelompok (free inquiry labs. Data penelitian dijaring melalui laporan mini-riset, presentasi oral dan poster serta wawancara.  Hasil penelitian  menunjukkan bahwa P2MBPI mini-riset setiap kelompok memberikan kontribusi terhadap kemunculan keterampilan laboratorium mikrobiologi yang cukup beragam. Hal ini selaras dengan tahapan proyek mulai dari pemilihan masalah dan topik mini-riset, sampai pengambilan keputusan proyek yang dilaksanakan oleh kelompok. Secara umum ruang lingkup topik proyek mini-riset mencakup empat bidang, yaitu mikrobiologi pertanian (tanah, mikrobiologi lingkungan (air, mikrobiologi kesehatan, dan mikrobiologi pangan. Hasil analisis kemunculan jenis keterampilan spesifik lab mikrobiologi dari laporan, presentasi oral, dan poster, serta wawancara menunjukkan bahwa sebagian besar kelompok menunjukkan persentase kemunculan jenis keterampilan yang tinggi (100%, yaitu pada keterampilan bekerja aseptik, keterampilan mengisolasi mikroba, sterilisasi, dan menggunakan mikroskop.  Kemunculan jenis keterampilan dengan persentase sedang (75% pada keterampilan identifikasi dan kultivasi mikroorganisme. Selanjutnya berdasarkan hasil wawancara mendalam pada 7 orang mahasiswa, menyatakan bahwa program pembelajaran mikrobiologi berbasis proyek inkuiri mini-riset ini juga sangat berarti, disamping mendapatkan keterampilan lab mikrobiologi, juga dapat membekali keterampilan meneliti (research skill mahasiswa biologi.  Dengan demikian P2MBPI mini-riset ini, perlu terus dikembangkan karena memberikan konstribusi yang

  10. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

    Science.gov (United States)

    Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto

    2016-01-01

    ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic. PMID:27901227

  11. The Experiment Production And Examination Of The U3Si2-AI Mini plates For Irradiation Test

    International Nuclear Information System (INIS)

    Supardjo; Boybul; Yowono; Susworo; Permana, S.

    1998-01-01

    The fuel plates containing U 3 Si 2 -AI dispersion fuel having respective loading of 3.55; 4.20; and 4.80 g/cm 3 were prepared by dispersing certain amount of U 3 Si 2 powder in the AI powder as matrix. The weight ratio of U 3 Si 2 and AI at different loading was chosen based on the 19.23 cm 3 volume basis fuel core calculation. Each fuel mixture was pressed into a fuel core having dimension of 100.20 x 60.35 x 3.15 +- (0.05) mm, which was then cut into mini fuel core having dimension of 16 x 8 x 3.15 +- (0.05) mm. The mini plates were prepared by picture and frame technique using AIMg2 as cladding material. The mini plates have been tested for blister, homogeneity, white spots, surface defects and their cladding thickness, revealing that out of 74 mini plates, they are ten (10) mini plates that have to be rejected due to blisters and white spots, thus of 64 mini plates can be further fabricated as samples for irradiation test

  12. Development of X-ray mini-probes for the Digiray RGX system

    International Nuclear Information System (INIS)

    Wojcik, R.; Kross, B.; Majewski, L.; Majewski, S.; Weisenberger, A.G.; Zorn, C.; Birt, E.A.; Parker, F.R.; Winfree, W.P.; Albert, R.D.; Albert, T.M.

    1994-01-01

    We have developed and tested a variety of X-ray mini-probes for the Reverse Geometry X-radiography trademark ,1 (RGX) system each having their own advantages and disadvantages. These mini-probes consist of small scintillators (as small as 2 mm in diameter and 5 mm long) attached to optical light guides (as long as 14 m) coupled to photomultipliers. Images produced with these probes show that even smaller probes and/or longer light guides may be fashioned. Such probes may be useful in both non-destructive evaluation and medical imaging. ((orig.))

  13. The performance of the Mini-Cog in a sample of low educational level elderly.

    Science.gov (United States)

    Ribeiro Filho, Sergio Telles; Lourenço, Roberto Alves

    2009-01-01

    To study the criterion validity of the Mini-Cog in low educational level elderly. Design: Cross-sectional and validation design. Setting: Policlínica Piquet Carneiro, an outpatient unit of Rio de Janeiro State University Hospital, in Brazil. Participants: A convenient sample consisting of 306 individuals, 65 yrs or older, selected from April 8 th to July 15 th , 2002. All participants underwent comprehensive geriatric evaluations which included the Mini-Mental State Examination (MMSE) and the cognitive part of the Cambridge Examination for Mental Disorders of the Elderly - Revised (CAMCOG-R). They were classified as demented or non-demented (DSM-IV). A post-hoc analysis was performed on the data from the 3 word recall test of the MMSE, and the Clock Drawing Test from the CAMCOG-R, and respective scores were added and interpreted in accordance with the Mini-Cog protocol. 293 individuals completed all the study steps; 211 had 4 or less years of schooling and were included in the data analysis. 32% had dementia. Mini-Cog sensitivity and specificity was consistently low independently of the different cut-off points considered. The best performance was found at the cut-off point of 2/3 which yielded sensitivity and specificity of 60% and 65%, respectively. The Mini-Cog is not a good cognitive screening tool for individuals with less than five years of formal education.

  14. Tissue interfaces dosimetry in small field radiotherapy with alanine/EPR mini dosimeters and Monte Carlo-Penelope simulation

    Energy Technology Data Exchange (ETDEWEB)

    Vega R, J. L.; Nicolucci, P.; Baffa, O. [Universidade de Sao Paulo, FFCLRP, Departamento de Fisica, Av. Bandeirantes 3900, Bairro Monte Alegre, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Chen, F. [Universidade Federale do ABC, CCNH, Rua Santa Adelia 166, Bangu, 09210-170 Santo Andre, Sao Paulo (Brazil); Apaza V, D. G., E-mail: josevegaramirez@yahoo.es [Universidad Nacional de San Agustin de Arequipa, Departamento de Fisica, Arequipa (Peru)

    2014-08-15

    The dosimetry system based on alanine mini dosimeters plus K-Band EPR spectrometer was tested in the tissue-interface dosimetry through the percentage depth-dose (Pdd) determination for 3 x 3 cm{sup 2} and 1 x 1 cm{sup 2} radiation fields sizes. The alanine mini dosimeters were produced by mechanical pressure from a mixture of 95% L-alanine and 5% polyvinyl alcohol (Pva) acting as binder. Nominal dimensions of these mini dosimeters were 1 mm diameter and 3 mm length as well as 3 - 4 mg mass. The EPR spectra of the mini dosimeters were registered using a K-Band (24 GHz) EPR spectrometer. The mini dosimeters were placed in a nonhomogeneous phantom and irradiated with 20 Gy in a 6 MV PRIMUS Siemens linear accelerator, with a source-to-surface distance of 100 cm using the small fields previously mentioned. The cylindrical non-homogeneous phantom was comprised of several disk-shaped plates of different materials in the sequence acrylic-bone cork-bone-acrylic, with dimensions 15 cm diameter and 1 cm thick. The plates were placed in descending order, starting from top with four acrylic plates followed by two bone plates plus eight cork plates plus two bone plates and finally, four acrylic plates (4-2-8-2-4). Pdd curves from the treatment planning system and from Monte Carlo simulation with Penelope code were determined. Mini dosimeters Pdd results show good agreement with Penelope, better than 95% for the cork homogeneous region and 97.7% in the bone heterogeneous region. In the first interface region, between acrylic and bone, it can see a dose increment of 0.6% for mini dosimeters compared to Penelope. At the second interface, between bone and cork, there is 9.1% of dose increment for mini dosimeter relative to Penelope. For the third (cork-bone) and fourth (bone-acrylic) interfaces, the dose increment for mini dosimeters compared to Penelope was 4.1% both. (Author)

  15. Tissue interfaces dosimetry in small field radiotherapy with alanine/EPR mini dosimeters and Monte Carlo-Penelope simulation

    International Nuclear Information System (INIS)

    Vega R, J. L.; Nicolucci, P.; Baffa, O.; Chen, F.; Apaza V, D. G.

    2014-08-01

    The dosimetry system based on alanine mini dosimeters plus K-Band EPR spectrometer was tested in the tissue-interface dosimetry through the percentage depth-dose (Pdd) determination for 3 x 3 cm 2 and 1 x 1 cm 2 radiation fields sizes. The alanine mini dosimeters were produced by mechanical pressure from a mixture of 95% L-alanine and 5% polyvinyl alcohol (Pva) acting as binder. Nominal dimensions of these mini dosimeters were 1 mm diameter and 3 mm length as well as 3 - 4 mg mass. The EPR spectra of the mini dosimeters were registered using a K-Band (24 GHz) EPR spectrometer. The mini dosimeters were placed in a nonhomogeneous phantom and irradiated with 20 Gy in a 6 MV PRIMUS Siemens linear accelerator, with a source-to-surface distance of 100 cm using the small fields previously mentioned. The cylindrical non-homogeneous phantom was comprised of several disk-shaped plates of different materials in the sequence acrylic-bone cork-bone-acrylic, with dimensions 15 cm diameter and 1 cm thick. The plates were placed in descending order, starting from top with four acrylic plates followed by two bone plates plus eight cork plates plus two bone plates and finally, four acrylic plates (4-2-8-2-4). Pdd curves from the treatment planning system and from Monte Carlo simulation with Penelope code were determined. Mini dosimeters Pdd results show good agreement with Penelope, better than 95% for the cork homogeneous region and 97.7% in the bone heterogeneous region. In the first interface region, between acrylic and bone, it can see a dose increment of 0.6% for mini dosimeters compared to Penelope. At the second interface, between bone and cork, there is 9.1% of dose increment for mini dosimeter relative to Penelope. For the third (cork-bone) and fourth (bone-acrylic) interfaces, the dose increment for mini dosimeters compared to Penelope was 4.1% both. (Author)

  16. Mini-Enterprise Projects: Friendship, Business and Learning

    Science.gov (United States)

    Riese, Hanne

    2013-01-01

    This article discusses how the mini-enterprise (ME) approach (Young Enterprise) can be understood as a tool for helping to achieve policy goals set for entrepreneurship. Analysis of 12 semi-structured interviews with 17-year-old students shows how social capital from friendship relations constitutes norms for interaction in MEs. To some extent,…

  17. INTRODUCING A LOW-COST MINI-UAV FOR THERMAL- AND MULTISPECTRAL-IMAGING

    Directory of Open Access Journals (Sweden)

    J. Bendig

    2012-07-01

    Full Text Available The trend to minimize electronic devices also accounts for Unmanned Airborne Vehicles (UAVs as well as for sensor technologies and imaging devices. Consequently, it is not surprising that UAVs are already part of our daily life and the current pace of development will increase civil applications. A well known and already wide spread example is the so called flying video game based on Parrot's AR.Drone which is remotely controlled by an iPod, iPhone, or iPad (http://ardrone.parrot.com. The latter can be considered as a low-weight and low-cost Mini-UAV. In this contribution a Mini-UAV is considered to weigh less than 5 kg and is being able to carry 0.2 kg to 1.5 kg of sensor payload. While up to now Mini-UAVs like Parrot's AR.Drone are mainly equipped with RGB cameras for videotaping or imaging, the development of such carriage systems clearly also goes to multi-sensor platforms like the ones introduced for larger UAVs (5 to 20 kg by Jaakkolla et al. (2010 for forestry applications or by Berni et al. (2009 for agricultural applications. The problem when designing a Mini-UAV for multi-sensor imaging is the limitation of payload of up to 1.5 kg and a total weight of the whole system below 5 kg. Consequently, the Mini-UAV without sensors but including navigation system and GPS sensors must weigh less than 3.5 kg. A Mini-UAV system with these characteristics is HiSystems' MK-Okto (www.mikrokopter.de. Total weight including battery without sensors is less than 2.5 kg. Payload of a MK-Okto is approx. 1 kg and maximum speed is around 30 km/h. The MK-Okto can be operated up to a wind speed of less than 19 km/h which corresponds to Beaufort scale number 3 for wind speed. In our study, the MK-Okto is equipped with a handheld low-weight NEC F30IS thermal imaging system. The F30IS which was developed for veterinary applications, covers 8 to 13 μm, weighs only 300 g, and is capturing the temperature range between −20 °C and 100 °C. Flying at a height of

  18. [White House Conference on Aging, 1981: Reports of the Mini-Conferences, MCR 1-42.

    Science.gov (United States)

    White House Conference on Aging, Washington, DC.

    This document contains the 42 reports from mini-conferences held in various nationwide locations prior to the 1981 White House Conference on Aging. Each report presents an overview of the topic, descriptions of particular problems, and statements of recommendations, based on the views of mini-conference participants, and made available to the…

  19. Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Marczak, Alana; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2017-09-15

    The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: 360° and 180° cone-beam computed tomography (CBCT) acquisition protocols. A small-volume 180° CBCT scan and a 360° CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up 360° CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intra-rater agreement. In this ex vivo study, we found that the 180° rotational acquisition was as effective as the conventional 360° rotational acquisition for the preoperative evaluation of potential mini-implant sites.

  20. Support for designing waste sorting systems: A mini review.

    Science.gov (United States)

    Rousta, Kamran; Ordoñez, Isabel; Bolton, Kim; Dahlén, Lisa

    2017-11-01

    This article presents a mini review of research aimed at understanding material recovery from municipal solid waste. It focuses on two areas, waste sorting behaviour and collection systems, so that research on the link between these areas could be identified and evaluated. The main results presented and the methods used in the articles are categorised and appraised. The mini review reveals that most of the work that offered design guidelines for waste management systems was based on optimising technical aspects only. In contrast, most of the work that focused on user involvement did not consider developing the technical aspects of the system, but was limited to studies of user behaviour. The only clear consensus among the articles that link user involvement with the technical system is that convenient waste collection infrastructure is crucial for supporting source separation. This mini review reveals that even though the connection between sorting behaviour and technical infrastructure has been explored and described in some articles, there is still a gap when using this knowledge to design waste sorting systems. Future research in this field would benefit from being multidisciplinary and from using complementary methods, so that holistic solutions for material recirculation can be identified. It would be beneficial to actively involve users when developing sorting infrastructures, to be sure to provide a waste management system that will be properly used by them.

  1. Energy-Water Nexus Relevant to Baseload Electricity Source Including Mini/Micro Hydropower Generation

    Science.gov (United States)

    Fujii, M.; Tanabe, S.; Yamada, M.

    2014-12-01

    Water, food and energy is three sacred treasures that are necessary for human beings. However, recent factors such as population growth and rapid increase in energy consumption have generated conflicting cases between water and energy. For example, there exist conflicts caused by enhanced energy use, such as between hydropower generation and riverine ecosystems and service water, between shale gas and ground water, between geothermal and hot spring water. This study aims to provide quantitative guidelines necessary for capacity building among various stakeholders to minimize water-energy conflicts in enhancing energy use. Among various kinds of renewable energy sources, we target baseload sources, especially focusing on renewable energy of which installation is required socially not only to reduce CO2 and other greenhouse gas emissions but to stimulate local economy. Such renewable energy sources include micro/mini hydropower and geothermal. Three municipalities in Japan, Beppu City, Obama City and Otsuchi Town are selected as primary sites of this study. Based on the calculated potential supply and demand of micro/mini hydropower generation in Beppu City, for example, we estimate the electricity of tens through hundreds of households is covered by installing new micro/mini hydropower generation plants along each river. However, the result is based on the existing infrastructures such as roads and electric lines. This means that more potentials are expected if the local society chooses options that enhance the infrastructures to increase micro/mini hydropower generation plants. In addition, further capacity building in the local society is necessary. In Japan, for example, regulations by the river law and irrigation right restrict new entry by actors to the river. Possible influences to riverine ecosystems in installing new micro/mini hydropower generation plants should also be well taken into account. Deregulation of the existing laws relevant to rivers and

  2. Genotype by Environment Effects on Potato Mini-Tuber Seed Production in an Aeroponics System

    Directory of Open Access Journals (Sweden)

    Julián F. Mateus-Rodriguez

    2014-11-01

    Full Text Available In order to evaluate the environmental effect on plant development and mini-tuber production of a diverse group of potato genotypes grown under an aeroponic system, a G × E interaction experiment was carried out in greenhouses located at CIP’s experimental stations in La Molina (Lima and Huancayo (Junín. Five contrasting environments were set-up and evaluated. A combined Analysis of Variance was performed for the variables “days to tuber set”, “days to senescence” and “plant height”. An Additive Main Effects and Multiplicative Interaction (AMMI Analysis was performed for yield variables: mini-tuber “weight” and “number of mini-tubers” per plant. There was a high variation in all the responses to the treatments. “Days to tuber set” was influenced by genetic responses, temperature and greenhouse Photosynthetically Active Radiation intensity. Considerable increases in the length of the vegetative cycle and plant height were recorded for all genotypes, and these were particularly notable in the warmer coastal environments. AMMI analysis showed that yield variables were primarily influenced by the genotypic effect followed by the genotype by environment interaction effect. The Venturana variety (T2 was the best performing genotype with a total average mini-tuber “weight” of 644 g per plant while the Chucmarina variety (T1 performed best for the variable “number of mini-tubers” with an overall average of 60.2 mini-tubers per plant. Both showed stability across different environments for these variables. The advanced clones T3 (395434.1, T5 (397077.16 and T6 (397073.16 showed stability for yield variables, but their performance was below the overall average of the trial. It is recommended that the environment and management should ideally be tailored to the genotype as this will result in significant yield gains.

  3. Long-term efficacy of a mini-course in radiation-reducing techniques in invasive cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Kuon, E. [Klinik Fraenkische Schweiz, Ebermannstadt (Germany). Abt. fuer Kardiologie; Empen, K.; Hummel, A.; Doerr, M.; Reffelmann, T.; Felix, S.B. [Ernst-Moritz-Arndt-Universitaet, Greifswald (Germany). Abt. fuer Innere Medizin B; Weitmann, K.; Hoffmann, W. [Ernst-Moritz-Arndt-Universitaet, Greifswald (Germany). Inst. fuer Versorgungsmedizin; Staudt, A. [Helios Kliniken, Schwerin (Germany). Abt. fuer Kardiologie und Angiologie

    2013-08-15

    Purpose: To validate the long-term efficacy of a 90-min. educational mini-course in less-irradiating cardiac interventional techniques. Materials and Methods: Before, two months after, and two years after the mini-course (periods I, II, and III), we analyzed the following radiation dose parameters for ten coronary angiographies (CA), performed by each of 7 cardiologists: total dose-area product (DAP), radiographic and fluoroscopic DAP fractions, number of radiographic frames and runs, and fluoroscopy time. Results: The median patient DAP for periods I, II and III was 31.4, 15.8 and 8.5 Gy x cm{sup 2}, respectively. The long-term effect was related to shorter median fluoroscopy times (180, 172, and 120 s), shorter (57, 52, and 45) and fewer (12, 12, and 10) radiographic runs, consistent collimation and restriction to an adequate image quality. Both radiographic DAP/frame (28.7, 17.0, and 18.4 mGy x cm{sup 2}) and fluoroscopic DAP/second (45.7, 24.2, and 10.0 mGy x cm{sup 2}) decreased significantly. The multivariate linear regression analysis confirmed the increasing efficacy of the mini-course itself (-44.6 and -60.7 %), and revealed a decreasing influence of the interventionalist's experience (-8.6 % and -4.9 % per 1,000 CAs, lifelong performed until the mini-course). The number of CAs performed after the mini-course did not influence the long-term DAP results. Conclusion: The presented educational mini-course allows a significant, long-lasting, and apparently ongoing reduction of patient radiation exposure due to CA. A self-surveillant documentation of relevant radiation parameters is well suited to monitor and improve each operator's individual long-term radiation-reducing efforts. (orig.)

  4. A STUDY ON MANAGEMENT OF CHRONIC SUBDURAL HAEMATOMA- BURR HOLE EVACUATION AND MINI CRANIOTOMY

    Directory of Open Access Journals (Sweden)

    Nandigama Pratap Kumar

    2016-11-01

    Full Text Available BACKGROUND Chronic SDH is one of the common neurosurgical conditions requiring surgical treatment. The incidence of chronic SDH is 1.7- 18 per 1,00,000 population. The incidence is higher in the elderly patients, i.e. 58 per 1,00,000. Various treatment modalities available for the treatment of chronic SDH indicate that there is no gold standard for the treatment of chronic SDH. Recurrence is the major problem following treatment and can be as high as 30%. Mini craniotomy is one of the surgical options that can offer better view of the subdural space and may allow us to efficiently clear the loculations and haematoma fluid and thereby decreasing the incidence of recurrences and the need for reoperations. Small craniotomies have not been studied well in the literature except for a few publications. In this study, we are comparing mini craniotomy and burr hole evacuation for the treatment of chronic SDH. MATERIALS AND METHODS All the patients with chronic subdural haematoma operated between August 2013 and January 2016. Patients with recurrent SDH on the same side and patients who underwent different procedures on either side (in case of bilateral haematomas were excluded from the study. The patients were operated by two senior surgeons with one surgeon doing burr hole evacuation and another doing mini craniotomy. Preoperative status and postoperative status was analysed. RESULTS All the patients were analysed both preoperatively and postoperatively. In both the groups, most of the patients shown improvement following surgery, but recurrences are more in burr hole group when compared to mini craniotomy. CONCLUSION Mini craniotomy allows better view of the subdural space and better evacuation of chronic subdural haematoma. Cure rate is higher with mini craniotomy compared to burr hole evacuation.

  5. Mini Games for Professional Awareness in Introductory Psychology

    NARCIS (Netherlands)

    Hummel, Hans; Nadolski, Rob; Eshuis, Jannes; Slootmaker, Aad

    2017-01-01

    Main problems with the current course Introduction to Psychology in our university is that students consider the content as too theoretical and insufficient in providing professional practice. Potential solutions are expected to come from mini-games that have proven to enable more active and

  6. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  7. Feelings of Women With Strong Family Histories Who Subsequent to Their Breast Cancer Diagnosis Tested BRCA Positive.

    Science.gov (United States)

    Joseph, Meera; Rab, Faiza; Panabaker, Karen; Nisker, Jeff

    2015-05-01

    Family physicians in Canada as reported in several studies do not recognize the importance of family history in relation to breast/ovarian cancer and thus Canadian women with strong family histories continue to develop early-onset breast cancer without the knowledge of or ability to make choices regarding increased surveillance or preventative strategies. This study explored the feelings of women who learned about their hereditary risk only after their diagnosis younger than 52 years and who eventually tested positive for a BRCA gene mutation. Thirty-four such women were mailed an invitation to participate in this research including a letter of information, consent form, and discussion prompts for their written narrative response. Rigorous mixed method analyses were performed using Charmaz-based qualitative analyses as well as quantitative analyses. Thirteen women (38.2%) responded with narratives for qualitative analysis from which 4 themes were coconstructed as follows: I, types of emotions; II, emotional response; III, coping with emotions; and IV, advice to women at similar risk. Women felt they should have learned about their hereditary risk from their family physician and through public education before their diagnosis. Although not experienced at the time of diagnosis, anger, frustration, and regret were experienced after receiving their BRCA results. These emotions arose from our research participants' lack of opportunity for prior genetic counseling and testing opportunity for genetic counseling and testing. With increased public and physician education, it is hoped that women with significant family histories of breast/ovarian cancer will be identified before diagnosis and given options regarding cancer surveillance and risk reduction strategies.

  8. Preliminary study on weapon grade uranium utilization in molten salt reactor miniFUJI

    Energy Technology Data Exchange (ETDEWEB)

    Aji, Indarta Kuncoro [Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung (Indonesia); Waris, A., E-mail: awaris@fi.itb.ac.id [Nuclear Physics and Biophysics Research Division, Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesa No. 10 Bandung 40132 (Indonesia)

    2014-09-30

    Preliminary study on weapon grade uranium utilization in 25MWth and 50MWth of miniFUJI MSR (molten salt reactor) has been carried out. In this study, a very high enriched uranium that we called weapon grade uranium has been employed in UF{sub 4} composition. The {sup 235}U enrichment is 90 - 95 %. The results show that the 25MWth miniFUJI MSR can get its criticality condition for 1.56 %, 1.76%, and 1.96% of UF{sub 4} with {sup 235}U enrichment of at least 93%, 90%, and 90%, respectively. In contrast, the 50 MWth miniFUJI reactor can be critical for 1.96% of UF{sub 4} with {sup 235}U enrichment of at smallest amount 95%. The neutron spectra are almost similar for each power output.

  9. Implementation of a linear mini accelerator for radiotherapy intraoperative

    International Nuclear Information System (INIS)

    Macias-Verde, D.; Yanez-Lopez, D.; Marti-Asenjo, J.; Sanchez-Carrascal, M.; Torres-Pozas, S.; Godoy-Cazorla, J. I.; Madan-Rodriguez, C.; Martin-Oliva, R.

    2013-01-01

    Has been defined the status initial reference of the lineal mini-accelerator Intrabeam PRS 500. The alternative worksheet in times of treatment provides an additional verification. The system is validated for clinical use. (Author)

  10. Assessment of Paclobutrazol’s Time and Concentration of Foliar Application on Production and Germination of Potato (Solanum tuberosum L. Mini-tube

    Directory of Open Access Journals (Sweden)

    B Saadatian

    2018-02-01

    Full Text Available Introduction Health and quality of potato (Solanum tuberosum L. seeds are important in the potato seed production technology. Moreover, the basic seed materials must be free of pathogens. Therefore tissue culture techniques are used at this stage in the laboratory to produce disease free seeds. Mini-tubers can be produced after acclimatization from plantlets as tissue culture which are planted at high densities in the greenhouse in beds or containers using different substrate mixtures, or even in hydroponic culture. Foliar application of growth regulators is a way to increase potato mini-tuber production. Growth regulators influence on potato mini-tuber dormancy. Triazoles, a family which Paclobutrazol belongs to them, have both fungitoxic and plant growth regulatory effects. In addition, they can also protect plants against various stresses. Therefore, the triazoles have been characterized as plant multi-protestants. Paclobutrazol changes the relationship between source and sink and by this way, affects plant production. Also, it can inhibit giberellic acid biosynthesis. Some morphological changes observed in paclobutrazol-treated plants include the inhibition of plant growth, decreased inter-nodal elongation and increased root to shoot ratios. Time of paclobutrazol foliar application is an important factor which changes plant characters (Lim et al., 2004. This study implemented to evaluate foliar application of paclobutrazol concentrations at different time on production and mini-tuber dormancy. Materials and Methods The factorial experiment based on randomized complete block design with four replications was conducted at the faculty of agriculture’s research greenhouse, Ferdowsi University of Mashhad, Iran, in 2013. Plantlets of Agria cv. produced from nodal tissue culture in Murashinge and Skoog (MS medium. After 25 days, plantlets of free disease and uniform exported to plastic pots with 12 cm diameter and 30 cm height. Perlite, cocopite

  11. Case Study: Mini-Case Studies: Small Infusions of Active Learning for Large-Lecture Courses

    Science.gov (United States)

    Carloye, Lisa

    2017-01-01

    In this article, the author introduces the usage of case studies to be an excellent method for engaging students through stories. The author notes she developed a series of mini-case studies that can be implemented, with a little advance preparation, within a 10- to 15-minute window during lecture. What makes them "mini" case studies?…

  12. Levan And Levansucrase-A Mini Review

    Directory of Open Access Journals (Sweden)

    Bruna Caroline Marques Goncalves

    2015-05-01

    Full Text Available Abstract Levansucrase is a fructosyltranferase that synthesizes levan and present great biotechnological interest. Its being widely used in therapeutic food cosmetic and pharmaceutical industries. Levansucrase is produced by many microorganisms such as the Bacillus subtilis Natto using the sucrose fermentation. In this mini-review we described some properties and functions of this important group of enzymes and the recent technologies used in the production and purification of levansucrase and levan.

  13. Trapped magnetic field of a mini-bulk magnet using YBaCuO at 77 K

    Science.gov (United States)

    Fujimoto, Hiroyuki; Kamijo, Hiroki

    2001-09-01

    Melt-processed rare earth (RE)123 superconductors have a high Jc at 77 K and high magnetic field. Solidification processes for producing (L)RE123 superconductors and pinning centers in the (L)RE123 matrix are effective for obtaining high Jc, leading to high-field application as a superconducting quasi-permanent bulk magnet with the liquid nitrogen refrigeration. One of the promising applications is a superconducting magnet for the magnetically levitated train. We fabricated a mini-superconducting bulk magnet of 200×100 mm2, consisting of 18 bulks, which are a square 33 mm on a side and 10 mm in thickness, and magnetized the mini-magnet by field cooling. The mini-magnet showed the trapped magnetic field of larger than 0.1 T on the surface of the outer vessel of the magnet. The present preliminary study discusses trapped magnetic field properties of the mini-bulk magnet using YBaCuO superconductors at 77 K.

  14. Observation of rat's colon polyps in real time by mini-endoscopy and raman spectroscopy

    Science.gov (United States)

    Andriana, Bibin Bintang; Mahardika, Anggara; Taketani, Akihiro; Sato, Hidetoshi

    2018-02-01

    Colorectal adenoma (CA) is a disease caused by various factors (such as genetic factors or environmental exposures). The appearance of colon polyp (CP) within colorectal might indicate the hint of CA development. Ball-lens hollow fiber Raman probe (BHRP) may has a high capability for detection of CA in living experimental animal and have already tested to rat's CP in this study, which was designed to collaborate between BHRP with mini-endoscopy to observe the biochemical alteration within normal colon tissue and rat's colon polyps in real time. BHRP and mini-endoscopy can distinguish the differences in their finger print spectra and make pictures the control and CP in the real time. At the first step, the real situation of normal colon and Rat's CP were washed by saline and observed with mini-endoscopy. BHRP was introduced to Dextran sodium sulphate (DSS)-induced Rat's CP to detect some of biochemical alteration. The main purpose of this study was to introduce mini-endoscopy to guide the BHRP for diagnosing of CP in real time and to compare it with spectra of normal colon (control group) in living rat. As the result, BHRP can provide the differences in band of control and CP group, which can inform that the biochemical of normal and CP has changed. As a major parameter to distinct normal and CP tissue were phosphatidylinositol, phosphodiester group, lipid, and collagen. Mini endoscopy and BHRP is very sensitive devices for diagnosing of CP in real time.

  15. The performance of the Mini-Cog in a sample of low educational level elderly

    Directory of Open Access Journals (Sweden)

    Sergio Telles Ribeiro Filho

    Full Text Available Abstract Objectives: To study the criterion validity of the Mini-Cog in low educational level elderly. Design: Cross-sectional and validation design. Setting: Policlínica Piquet Carneiro, an outpatient unit of Rio de Janeiro State University Hospital, in Brazil. Participants: A convenient sample consisting of 306 individuals, 65 yrs or older, selected from April 8th to July 15th, 2002. Methods: All participants underwent comprehensive geriatric evaluations which included the Mini-Mental State Examination (MMSE and the cognitive part of the Cambridge Examination for Mental Disorders of the Elderly - Revised (CAMCOG-R. They were classified as demented or non-demented (DSM-IV. A post-hoc analysis was performed on the data from the 3 word recall test of the MMSE, and the Clock Drawing Test from the CAMCOG-R, and respective scores were added and interpreted in accordance with the Mini-Cog protocol. Results: 293 individuals completed all the study steps; 211 had 4 or less years of schooling and were included in the data analysis. 32% had dementia. Mini-Cog sensitivity and specificity was consistently low independently of the different cut-off points considered. The best performance was found at the cut-off point of 2/3 which yielded sensitivity and specificity of 60% and 65%, respectively. Conclusion: The Mini-Cog is not a good cognitive screening tool for individuals with less than five years of formal education.

  16. Efficacy of biofeedback therapy via a mini wireless device on sleep bruxism contrasted with occlusal splint: a pilot study

    Science.gov (United States)

    Gu, WeiPing; Yang, Jie; Zhang, FeiMin; Yin, XinMin; Wei, XiaoLong; Wang, Chen

    2015-01-01

    Abstract The putative causes of bruxism are multifactorial and there are no definite measures for bruxism management. The aim of this study was to evaluate the efficacy of biofeedback therapy on sleep bruxism, compared with occlusal splint. Twenty-four volunteers with sleep bruxism were divided into two groups: the GTB group that were treated with biofeedback therapy (n  = 12) and the GTO group that were treated with occlusal splint (n  = 12). A mini pressure sensor integrated with a monitoring circuit by use of a maxillary biofeedback splint was fabricated. To foster the relaxation of the masticatory muscles and the nervous system, the wireless device received signals from bruxism events and vibrations alerted the bruxer when the threshold was exceeded. Total episodes and average duration of bruxism events during 8 hours of sleep were analyzed with the monitoring program (TRMY1.0). After 6 and 12 weeks, the episodes (P  =  0.001) and duration (P 0.05). Furthermore, the episodes had significant differences between the GTB group and the GTO group after the same period of treatment (P  =  0.000). The results suggest that biofeedback therapy may be an effective and convenient measure for mild bruxers, when compared with occlusal splint therapy. The mini wireless biofeedback method may be of value for the diagnosis and management of bruxism in the future. PMID:25859272

  17. Office-based 3D-CT examined in the sitting position is useful for diagnosis of patulous eustachian tube (pET)

    International Nuclear Information System (INIS)

    Kikuchi, Toshiaki; Oshima, Takeshi; Kobayashi, Toshimitsu

    2010-01-01

    The pET symptoms are tended to be masked in the recumbent position. CT for pET should be examined in the sitting position. CT was performed under the resting and Valsalva's condition. Completely open ET was observed in 79.2% of the pET group (n=111), but in none of the control group (n=30). The average ET-gram showed an occlusive zone (OZ) in medial to the isthmus under both conditions in only control group. Trans-tympanic silicone plug insertion was thought to be reasonable technique because of obliteration approach to isthmus. Office-based CT examined in the sitting position is useful for diagnosis and evaluation of pET. (author)

  18. Amelioration of Muscle and Nerve Pathology in LAMA2 Muscular Dystrophy by AAV9-Mini-Agrin

    Directory of Open Access Journals (Sweden)

    Chunping Qiao

    2018-06-01

    Full Text Available LAMA2-related muscular dystrophy (LAMA2 MD is the most common and fatal form of early-onset congenital muscular dystrophies. Due to the large size of the laminin α2 cDNA and heterotrimeric structure of the protein, it is challenging to develop a gene-replacement therapy. Our group has developed a novel adeno-associated viral (AAV vector carrying the mini-agrin, which is a non-homologous functional substitute for the mutated laminin α2. A significant therapeutic effect in skeletal muscle was observed in our previous study using AAV serotype 1 (AAV1. In this investigation, we examined AAV9 vector, which has more widespread transduction than AAV1, to determine if the therapeutic effects could be further improved. As expected, AAV9-mini-agrin treatment offered enhanced therapeutic effects over the previously used AAV1-mini-agrin in extending mouse lifespan and improvement of muscle pathology. Additionally, overexpression of mini-agrin in peripheral nerves of dyw/dyw mice partially amended nerve pathology as evidenced by improved motor function and sensorimotor processing, partial restoration of myelination, partial restoration of basement membrane via EM examination, as well as decreased regeneration of Schwann cells. In conclusion, our studies indicate that overexpression of mini-agrin into dyw/dyw mice offers profound therapeutic effects in both skeletal muscle and nervous system. Keywords: LAMA2, mini-agrin, muscular dystrophy, CMD, AAV, gene therapy

  19. Vaporization inside a mini microfin tube: experimental results and modeling

    Science.gov (United States)

    Diani, A.; Rossetto, L.

    2015-11-01

    This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.

  20. Comparison of flexible ureterorenoscopy and mini-percutaneous nephrolithotomy in treatment of lower calyceal stones smaller than 2 cm.

    Science.gov (United States)

    Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan

    2016-01-01

    To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.

  1. Purification and characterization of mutant miniPlasmin for thrombolytic therapy

    Directory of Open Access Journals (Sweden)

    Lin Xiaotao

    2013-01-01

    Full Text Available Abstract Background Previous animal studies by us and others have indicated that catheter-administered plasmin or its des-kringle derivatives may be more appropriate alternatives to plasminogen activators for treating thrombolytic diseases, since it has a very short serum half-life and therefore does not result in hemorrhaging. We have previously produced recombinant miniPlasmin (mPlasmin that was proven suitable for treating peripheral arterial occlusion in animal models. However, our previous results showed that non-specific cleavage at position K698 of mPlasmin during activation hindered the further development of this promising therapeutic candidate. In order to minimize or eliminate the non-specific cleavage problem, we performed saturation mutagenesis at the K698 position to develop a mutant form of mPlasmin for thrombolytic therapy. Methods We changed K698 to 16 other amino acids, with preferred E. coli codons. Each of these mutants were expressed in E. coli as inclusion bodies and then refolded, purified, and subsequently characterized by detailed kinetic assays/experiments/studies which identified highly active mutants devoid of non-specific cleavage. Results Activation studies indicated that at those conditions in which the wild type enzyme is cut at the non-specific position K698, the active mutants can be activated without being cleaved at this position. Conclusions From the above results, we selected two mutants, K698Q and K698N, as our lead candidates for further thrombolytic drug developments. The selected mutants are potentially better therapeutic candidates for thrombolytic therapy.

  2. Vacuum design for a superconducting mini-collider

    International Nuclear Information System (INIS)

    Barletta, W.A.; Monteiro, S.

    1991-01-01

    The phi factory (Superconducting Mini-Collider or SMC) proposed for construction at UCLA is a single storage ring with circulating currents of 2 A each of electrons and positrons. The small circumference exacerbates the difficulties of handling the gas load due to photodesorption from the chamber walls. The authors analyze the vacuum system for the phi factory to specify design choices

  3. A special mini-extrapolation chamber for calibration of 90Sr+90Y sources

    International Nuclear Information System (INIS)

    Oliveira, Mercia L; Caldas, Linda V E

    2005-01-01

    90 Sr+ 90 Y applicators are commonly utilized in brachytherapy, including ophthalmic procedures. The recommended instruments for the calibration of these applicators are extrapolation chambers, which are ionization chambers that allow the variation of their sensitive volume. Using the extrapolation method, the absorbed dose rate at the applicator surface can be determined. The aim of the present work was to develop a mini-extrapolation chamber for the calibration of 90 Sr+ 90 Y beta ray applicators. The developed mini-chamber has a 3.0 cm outer diameter and is 11.3 cm in length. An aluminized polyester foil is used as the entrance window while the collecting electrode is made of graphited polymethylmethacrylate. This mini-chamber was tested in 90 Sr+ 90 Y radiation beams from a beta particle check source and with a plane ophthalmic applicator, showing adequate results

  4. Cooling down MiniGRAIL to milli-Kelvin temperatures

    NARCIS (Netherlands)

    de Waard, A.; de Waard, A.; Gottardi, L.; Bassan, M.; Coccia, E.; Fafone, V.; Flokstra, Jakob; Karbalai-Sadegh, A.; Minenkov, Y.; Moleti, A.; Pallottino, G.V.; Podt, M.; Pors, B.J.; Reincke, W; Rocchi, A.; Shumack, A.; Srinivas, S.; Visco, M.; Frossati, G.

    2004-01-01

    The latest developments in the construction of the ultra-cryogenic spherical detector MiniGRAIL are presented. The room temperature part of the vibration isolation system was improved and provided with an attenuation of about 60 dB around 3 kHz. The transfer function of the cryogenic stages gave

  5. Water Boiler Change-Over in Mini-TPP Mode

    Directory of Open Access Journals (Sweden)

    B. A. Bayrashevsky

    2011-01-01

    Full Text Available The paper considers water boiler modernization by its change-over in mini-TPP mode with an expansion tank and a heating turbine of small capacity.  A software complex permitting to evaluate competitive ability of such water boiler modernization in comparison with a cogeneration plant.

  6. Cerebral perfusion imaging in HIV positive patients

    International Nuclear Information System (INIS)

    Kundley, Kshama; Chowdhury, D.; Lele, V.R.; Lele, R.D.

    1998-01-01

    Full text: Twelve human immunodeficiency virus (HIV) positive patients were studied by SPECT cerebral perfusion imaging 1 hour post injection of 15 mCi of 99m Tc-ECD under ideal conditions with a triple head gamma camera (Prism 3000 X P LEUHR), fanbeam collimators followed by Folstein Mini Mental Status Examination (FMMSE) and AIDS dementia complex (ADC) staging on the same day. All 12 patients were male, in the age range of 23-45 y (mean 31 y). The infected status was diagnosed by ELISA (10 patients) or Western blot (5 patients). The interval between diagnosis and imaging ranged from 1 month - 35 months (mean 15.3 months). Two patients were alcoholic and 2 were smokers. None of them had CNS disorder clinically. ADC staging and FMMSE could be performed in 4 patients. Two patients were normal (stage 0) and 2 were subclinical (stage 0.5) on ADC staging. FMMSE revealed normal or near normal status (mean score 35; maximum score 36). Cerebral perfusion images were interpreted simultaneously by 3 observers blind towards history and examination using semi-quantitative and quantitative methods by consensus. It revealed multiple areas of hypoperfusion, viz. temporal (11 patients (91 %), parietal 10 patients (83%), frontal 9 patients (75%, pre and post central gyrus 7 patients (58%), occipital 6 patients (50%) cingulate gyrus and cerebellum 5 patients (41%) and thalamic in 2 patients (16%). Hyper perfusion in caudate nuclei was noted in 10 patients (83%). The study reveals presence of multiple perfusion abnormalities on cerebral perfusion imaging in HIV positive patients who have normal/near normal mental status suggesting precedence of perfusion abnormality over clinically apparent mental deficit

  7. Acceptability and feasibility of mini-clinical evaluation exercise as a formative assessment tool for workplace-based assessment for surgical postgraduate students

    Directory of Open Access Journals (Sweden)

    M K Joshi

    2017-01-01

    Full Text Available Background: Despite an increasing emphasis on workplace-based assessment (WPBA during medical training, the existing assessment system largely relies on summative assessment while formative assessment is less valued. Various tools have been described for WPBA, mini-clinical evaluation exercise (mini-CEX being one of them. Mini-CEX is well accepted in Western countries, however, reports of its use in India are scarce. We conducted this study to assess acceptability and feasibility of mini-CEX as a formative assessment tool for WPBA of surgical postgraduate students in an Indian setting. Methods: Faculty members and 2nd year surgical residents were sensitized toward mini-CEX and requisite numbers of exercises were conducted. The difficulties during conduction of these exercises were identified, recorded, and appropriate measures were taken to address them. At the conclusion, the opinion of residents and faculty members regarding their experience with mini-CEX was taken using a questionnaire. The results were analyzed using simple statistical tools. Results: Nine faculty members out of 11 approached participated in the study (81.8%. All 16 2nd year postgraduate surgical residents participated (100%. Sixty mini-CEX were conducted over 7 months. Each resident underwent 3–5 encounters. The mean time taken by the assessor for observation was 12.3 min (8–30 min while the mean feedback time was 4.2 min (3–10 min. The faculty reported good overall satisfaction with mini-CEX and found it acceptable as a formative assessment tool. Three faculty members (33.3% reported mini-CEX as more time-consuming while 2 (22.2% found it difficult to carry the exercises often. All residents accepted mini-CEX and most of them reported good to high satisfaction with the exercises conducted. Conclusions: Mini-CEX is well accepted by residents and faculty as a formative assessment tool. It is feasible to utilize mini-CEX for WPBA of postgraduate students of surgery.

  8. Identifying the most efficient items from the Mini-Mental State Examination for cognitive function assessment in older Taiwanese patients.

    Science.gov (United States)

    Lou, Meei-Fang; Dai, Yu-Tzu; Huang, Guey-Shiun; Yu, Po-Jui

    2007-03-01

    The purpose of the study was to identify the most efficient items from the Mini-Mental State Examination for assessment of cognitive function. The Mini-Mental State Examination is the most frequently used cognitive screening instrument. However, the Mini-Mental State Examination has been criticized for insensitivity to mild cognitive dysfunction, limited memory assessment and variability in level of difficulty of the individual items. This study used secondary data analysis. Item response theory two-parameter model was used to analyse the data from the admission assessment of mental status by the Mini-Mental State Examination for 801 patients. By using item response analysis, 16 items were selected from the original 30-item Mini-Mental State Examination. The 16 items included mainly the measures of orientation, recall and attention and calculation. The internal consistency of the 16-item Mini-Mental State Examination was 0.84. The proposed new cut-off point for the 16-item Mini-Mental State Examination was 11. The correct classification rate was 0.94, the sensitivity was 100% and the specificity was 97.4%, when compared with the original 30-item Mini-Mental State Examination from the cut-off point of 24. This new cut-off point was determined for the purpose of over-identifying patients at risk so as to ensure early detection of and prevention from the onset of cognitive disturbance. Only a few items are needed to describe the subject's cognitive status. Using item response theory analysis, the study found that the Mini-Mental State Examination could be simplified. Deleting the items with less variation makes this assessment tool not only shorter, easier to administer and less strenuous for respondents, but also enables one to maintain validity as a cognitive function test for clinical setting.

  9. Orthodontic intrusion : Conventional and mini-implant assisted intrusion mechanics

    Directory of Open Access Journals (Sweden)

    Anup Belludi

    2012-01-01

    intrusion has revolutionized orthodontic anchorage and biomechanics by making anchorage perfectly stable. This article addresses various conventional clinical intrusion mechanics and especially intrusion using mini-implants that have proven effective over the years for intrusion of maxillary anteriors.

  10. Beta-spectrometer with magnetic filter of mini orange type

    International Nuclear Information System (INIS)

    Gorozhankin, V.M.; Gromov, K.Ya.; Kalinnikov, V.G.; Sereeter, Z.; Fominykh, V.I.; Malikov, Sh.R.; Yuldashev, M.B.

    1997-01-01

    At the ISOL facility YASNAPP-2 a β-spectrometer with a magnetic filter of the miniorange type is constructed to measure γ-ray internal conversion coefficients. The magnetic filter of the mini orange type is an assemblage of permanent magnets creating a toroidal magnetic field perpendicular to the electron trajectories from the source to the Si(Li) detector. The chosen profile of the permanent magnets allowed electron registration in the defined energy energy interval with some transmission increase. There are two sets of permanent magnets of the different thickness. Varying the type and number of permanent magnets one can set the detected electron energy intervals in a 50-2500 keV range. The efficiency of the spectrometer was investigated for different assemblages of the mini orange magnet. The facility can be used for the e-γ coincidence investigation. (A.A.D.)

  11. Thermalization of mini-jets in a quark–gluon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Iancu, Edmond, E-mail: edmond.iancu@cea.fr; Wu, Bin, E-mail: bin.wu.phys@gmail.com [Institut de Physique Théorique, CEA Saclay, CNRS UMR 3681, F-91191 Gif-sur-Yvette (France); Department of Physics, The Ohio State University, Columbus, OH 43210 (United States)

    2016-12-15

    We present the complete physical picture for the evolution of a high-energy jet propagating through a weakly-coupled quark-gluon plasma (QGP) by analytical and numerical investigation of thermalization of the soft components of the jet. Our results support the following physical picture: the leading particle emits a significant number of mini-jets which promptly evolve via multiple branching and thus degrade into a myriad of soft gluons, with energies of the order of the medium temperature T. Via elastic collisions with the medium constituents, these soft gluons relax to local thermal equilibrium with the plasma over a time scale which is considerably shorter than the typical lifetime of the mini-jet. The thermalized gluons form a tail which lags behind the hard components of the jet. Together with the background QGP, they behave hydrodynamically.

  12. Are mini DNA-barcodes sufficiently informative to resolve species ...

    Indian Academy of Sciences (India)

    ... between mini-barcode and the full- length DNA barcode was carried out in Microsoft Excel. (http://www.office.microsoft.com). ..... Received 15 June 2013, in final revised form 5 April 2014; accepted 3 June 2014. Unedited version published ...

  13. A mini-library of TBA analogues containing 3'-3' and 5'-5' inversion of polarity sites.

    Science.gov (United States)

    Esposito, V; Galeone, A; Mayol, L; Randazzo, A; Virgilio, A; Virno, A

    2007-01-01

    Several researches have been devoted to structure-activity relationship and to post-SELEX modifications of the thrombin binding aptamer (TBA), one of the first aptamers discovered by the SELEX methodology. However, no studies on TBA dealing with the effects of introduction of inversion of polarity sites have been reported yet. In this frame, we have undertaken the synthesis and the study of a mini-library composed of several TBA analogues containing a 3'-3' or a 5'-5' inversion of polarity site at different positions into the sequence. Particularly, in this article, we present preliminary results about their structural and biological properties.

  14. [Our experience with mini tapes (TVT Secur and MiniArc) in the surgery for stress urinary incontinence].

    Science.gov (United States)

    Jiménez Calvo, J; Hualde Alfaro, A; Raigoso Ortega, O; Cebrian Lostal, J L; Alvarez Bandres, S; Jiménez Parra, J; Montesino Semper, M; Santiago Gonzalez de Garibay, A

    2008-01-01

    The purpose of this publication is to describe the surgical technique, assess complications and short-term results of TVT secur and MiniArc tapes. From October 2006 to August 2007 it was carried out the surgical correction with TVT Secur,Women's Health & Urology, Ethicon, Johnson & Johnson, placing the tape as a hammock, to 51 patients, 38 of them with pure stress incontinence and 13 with mixed incontinence and with an average age of 57 years. From September 2007 to February 2008 41 patients, 33 of them with pure stress incontinence and 8 with mixed incontinence, with an average of age of 58 years were operated with AMS Miniarc swing system tape, posted on hammock. All procedures were performed with sedoanalgesia and Ambulatory Surgery regime. Patients were monitored in outpatient visits one month, 3 months and one year after surgical procedure. Medical history and questionnaire and ICIQ-SF, to which we added a question to quantify the degree of satisfaction, as well as physical examination, were done. We compared the results of both technical procedures and statistical survey was conducted by Student test. [Analysis with SPSS software (V14.0)]. The median follow-up in TVT secur group was 328 days (range 163-522 days) and 101 days (range 41-209 days) inthe MiniArc group. We only had one (TVT secur group) surgical complication in all the series (92 patients) being a bladder perforation. Taking into account that we read a negative test effort as an objective cure in the TVT secur group, 80.4% patients are cured and 90.2% inthe MiniArc group without significant difference between both groups (p 0095). To assess the subjective healing we utilized the ICIQ-SF test and the satisfaction extra-question and we noted that there is no significant difference between the first and third month controls. (90% of patients satisfied). 80% of patients were completely satisfied in the first year control that was only performed to TVT secur group. These new tapes show fewer

  15. Implementation of MINI-PACS using the DICOM converter on the Web

    International Nuclear Information System (INIS)

    Ji, Youn Sang

    2000-01-01

    In recent years, medical procedures have become more complex, while financial pressures for shortened hospital stays and increased efficiency in patient care have increased. As a result, several shortcomings of present film-based systems for managing medical images have become apparent. Maintaining film space is labor intensive and consumes valuable space. Because only single copies of radiological examinations exist, they are prone to being lost or misplaced, thereby consuming additional valuable time and expense. In this paper, MINI-PACS for image archiving, transmission, and viewing offers a solution to these problems. Proposed MINI-PACS consists of mainly four parts such as Web Module, Client-Server Module, Internal Module, Acquisition Module. In addition, MINI-PACS system includes DICOM Converter that Non-DICOM file format converts standard file format. In Client-Server Module case, Proposed system is combined both SCU(Service Class User: Client) part and SCP(Service Class Provider: Server) part therefore this system provides the high resolution image processing techniques based on windows platform. Because general PACS system is too expensive for Medium and Small hospitals to install and operate the full-PACS. Also, we constructed Web Module for database connection through the WWW.=20

  16. Mandibular Two Mini Implants Overdenture Using Magnetic Attachments: A Case Report

    Directory of Open Access Journals (Sweden)

    Anna Miyayasu

    2017-12-01

    Full Text Available Many patients with an edentulous mandible struggle to use complete dentures. The instability of such dentures caused by the lack of retention, often causes discomfort, as well as functional and psychosocial problems, which can be signifcantly improved using implant overdentures with retentive attachments. This case report describes a successful case of a mandibular implant overdenture using two mini implants and magnetic attachments for an elderly edentulous patient. Case Report: A 62-year-old female with a thin mandibular bone ridge presented with complaints of pain caused by an unstable and unretentive complete mandibular denture. This patient received two mini implants (diameter: 2.6 mm; length: 12 mm with magnetic attachments. After three months, magnetic assemblies with magnetic attraction of 400 gf were incorporated into the intaglio surface of her mandibular overdenture. At 11 months, magnetic attraction was changed from 400 gf to 600 gf to provide a stronger magnetic force for improving the retention of this denture. Conclusion: Based on a two-year follow-up period, the mandibular two mini implants overdenture with magnetic attachments was successful in improving the patient’s general satisfaction with her dentures

  17. Altered fibre types in gastrocnemius muscle of high wheel-running selected mice with mini-muscle phenotypes.

    Science.gov (United States)

    Guderley, Helga; Joanisse, Denis R; Mokas, Sophie; Bilodeau, Geneviève M; Garland, Theodore

    2008-03-01

    Selective breeding of mice for high voluntary wheel running has favoured characteristics that facilitate sustained, aerobically supported activity, including a "mini-muscle" phenotype with markedly reduced hind limb muscle mass, increased mass-specific activities of oxidative enzymes, decreased % myosin heavy chain IIb, and, in the medial gastrocnemius, reduced twitch speed, reduced mass-specific isotonic power, and increased fatigue resistance. To evaluate whether selection has altered fibre type expression in mice with either "mini" or normal muscle phenotypes, we examined fibre types of red and white gastrocnemius. In both the medial and lateral gastrocnemius, the mini-phenotype increased activities of oxidative enzymes and decreased activities of glycolytic enzymes. In red muscle samples, the mini-phenotype markedly changed fibre types, with the % type I and type IIA fibres and the surface area of type IIA fibres increasing; in addition, mice from selected lines in general had an increased % type IIA fibres and larger type I fibres as compared with mice from control lines. White muscle samples from mini-mice showed dramatic structural alterations, with an atypical distribution of extremely small, unidentifiable fibres surrounded by larger, more oxidative fibres than normally present in white muscle. The increased proportion of oxidative fibres and these atypical small fibres together may explain the reduced mass and increased mitochondrial enzyme activities in mini-muscles. These and previous results demonstrate that extension of selective breeding beyond the time when the response of the selected trait (i.e. distance run) has levelled off can still modify the mechanistic underpinnings of this behaviour.

  18. Factors Influencing Mini-CEX Rater Judgments and Their Practical Implications: A Systematic Literature Review.

    Science.gov (United States)

    Lee, Victor; Brain, Keira; Martin, Jenepher

    2017-06-01

    At present, little is known about how mini-clinical evaluation exercise (mini-CEX) raters translate their observations into judgments and ratings. The authors of this systematic literature review aim both to identify the factors influencing mini-CEX rater judgments in the medical education setting and to translate these findings into practical implications for clinician assessors. The authors searched for internal and external factors influencing mini-CEX rater judgments in the medical education setting from 1980 to 2015 using the Ovid MEDLINE, PsycINFO, ERIC, PubMed, and Scopus databases. They extracted the following information from each study: country of origin, educational level, study design and setting, type of observation, occurrence of rater training, provision of feedback to the trainee, research question, and identified factors influencing rater judgments. The authors also conducted a quality assessment for each study. Seventeen articles met the inclusion criteria. The authors identified both internal and external factors that influence mini-CEX rater judgments. They subcategorized the internal factors into intrinsic rater factors, judgment-making factors (conceptualization, interpretation, attention, and impressions), and scoring factors (scoring integration and domain differentiation). The current theories of rater-based judgment have not helped clinicians resolve the issues of rater idiosyncrasy, bias, gestalt, and conflicting contextual factors; therefore, the authors believe the most important solution is to increase the justification of rater judgments through the use of specific narrative and contextual comments, which are more informative for trainees. Finally, more real-world research is required to bridge the gap between the theory and practice of rater cognition.

  19. Mini buffy coat photopheresis for children and critically ill patients with extracorporeal photopheresis contraindications.

    Science.gov (United States)

    Hackstein, Holger; Misterek, Joachim; Nockher, Angelika; Reiter, Alfred; Bein, Gregor; Woessmann, Willi

    2009-11-01

    Conventional extracorporeal photopheresis (ECP) has proven efficacy for the treatment of several diseases but is limited to patients with sufficient body weight. A novel simplified mini buffy coat ECP technique that allows treatment of small children and patients with apheresis contraindications has been developed. White blood cell (WBC)-rich buffy coat fractions were prepared from 5 to 8 mL/kg whole blood in a closed system, diluted, and ultraviolet A (UVA)-irradiated after addition of 8-methoxypsoralen (8-MOP). Apoptosis and cell death were analyzed by annexin V and 7-aminoactinomycin staining. Lymphocyte proliferation was measured after CD3/CD28 and phytohemagglutinin (PHA) stimulation. Autologous residual blood and UVA-irradiated buffy coat were returned to the patients. Fifty-six mini buffy coat ECP procedures were applied to three children with acute steroid-refractory skin graft-versus-host disease and apheresis contraindications. Mean whole blood and buffy coat volumes were 166 (+/-61.8) and 8 (+/-1.6) mL, respectively, and resulted in a hematocrit of 2.2% (+/-0.4) after saline dilution (median +/- SD). UVA irradiation of 8-MOP buffy coat preparations resulted in significant induction of WBC apoptosis at 48-72 hours (p laboratory side effects were observed during mini ECP procedures and the three patients responded to the therapy. Mini buffy coat ECP induces apoptosis and lymphocyte proliferation inhibition, both of which occur after standard ECP. This study proposes that mini buffy coat ECP be used as a simple and inexpensive alternative to classical ECP in children and adult patients with apheresis contraindications.

  20. Matrix-mini-tablets of lornoxicam for targeting early morning peak symptoms of rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Abdul Hadi Mohd

    2014-05-01

    Full Text Available Objective(s: The aim of present research was to develop matrix-mini-tablets of lornoxicam filled in capsule for targeting early morning peak symptoms of rheumatoid arthritis. Materials and Methods:Matrix-mini-tablets of lornoxicam were prepared by direct compression method using microsomal enzyme dependent and pH-sensitive polymers which were further filled into an empty HPMC capsule. To assess the compatibility, FT-IR and DSC studies for pure drug, polymers and their physical mixture were performed. The formulated batches were subjected to physicochemical studies, estimation of drug content, in vitro drug release, drug release kinetics, and stability studies. Results:  When FTIR and DSC studies were performed it was found that there was no interaction between lornoxicam and polymers which used. All the physicochemical properties of prepared matrix-mini-tablets were found to be in normal limits. The percentage of drug content was found to be 99.60±0.07%. Our optimized matrix mini-tablets-filled-capsule formulation F30 released lornoxicam after a lag time of 5.02±0.92 hr, 95.48±0.65 % at the end of 8 hr and 99.90±0.83 % at the end of 12 hr. Stability was also found for this formulation as per the guidelines of International Conference on Harmonisation of Technical Requirements of Pharmaceuticals for Human Use. Conclusion: A novel colon targeted delivery system of lornoxicam was successfully developed by filling matrix-mini-tablets into an empty HPMC capsule shell for targeting early morning peak symptoms of rheumatoid arthritis.

  1. Perlindungan Hukum Hak Kekayaan Intelektual (Hki) Dalam Waralaba Retail Mini Market Di Yogyakarta

    OpenAIRE

    Hariyanto Hariyanto, S.H., M.KN

    2009-01-01

    Franchise business is more happening in Indonesia. This fast development indicates an interesting investment which on the same time helps the business subjects in starting their own business with a low risk. The franchise business which commonly stable is retail business. One of retail business which serves the main needs and daily needs is mini market Alfamart and Indomaret. This research aims to identify the IPR which the franchise's object between franchisor and franchisee in the mini mark...

  2. Civil mini-RPA's for the 1980's: Avionics design considerations. [remotely piloted vehicles

    Science.gov (United States)

    Karmarkar, J. S.

    1975-01-01

    A number of remote sensing or surveillance tasks (e.g., fire fighting, crop monitoring) in the civilian sector of our society may be performed in a cost effective manner by use of small remotely piloted aircraft (RPA). This study was conducted to determine equipment (and the associated technology) that is available, and that could be applied to the mini-RPA and to examine the potential applications of the mini-RPA with special emphasis on the wild fire surveillance mission. The operational considerations of using the mini-RPA as affected by government regulatory agencies were investigated. These led to equipment requirements (e.g., infra-red sensors) over and above those for the performance of the mission. A computer technology survey and forecast was performed. Key subsystems were identified, and a distributed microcomputer configuration, that was functionally modular, was recommended. Areas for further NASA research and development activity were also identified.

  3. Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits

    Directory of Open Access Journals (Sweden)

    Jea-Beom Park

    2014-01-01

    Full Text Available Objective. This study aimed to evaluate effects of type 1 diabetes mellitus and mini-implant placement method on the primary stability of mini-implants by comparing mechanical stability and microstructural/histological differences. Methods. After 4 weeks of diabetic induction, 48 mini-implants (24 self-tapping and 24 self-drilling implants were placed on the tibia of 6 diabetic and 6 normal rabbits. After 4 weeks, the rabbits were sacrificed. Insertion torque, removal torque, insertion energy, and removal energy were measured with a surgical engine on 8 rabbits. Remaining 4 rabbits were analyzed by microcomputed tomography (micro-CT and bone histomorphometry. Results. Total insertion energy was higher in self-drilling groups than self-tapping groups in both control and diabetic groups. Diabetic groups had more trabecular separation in bone marrow than the control groups in both SD and ST groups. Micro-CT analysis showed deterioration of bone quality in tibia especially in bone marrow of diabetic rabbits. However, there was no statistically significant correlation between self-drilling and self-tapping group for the remaining measurements in both control and diabetic groups. Conclusions. Type 1 diabetes mellitus and placement method of mini-implant did not affect primary stability of mini-implants.

  4. The efficacy of maxillary protraction protocols with the micro-implant-assisted rapid palatal expander (MARPE) and the novel N2 mini-implant-a finite element study.

    Science.gov (United States)

    Moon, Won; Wu, Kimberley W; MacGinnis, Matthew; Sung, Jay; Chu, Howard; Youssef, George; Machado, Andre

    2015-01-01

    Maxillary protraction with the novel N2 mini-implant- and micro-implant-assisted rapid palatal expander (MARPE) can potentially provide significant skeletal effects without surgery, even in older patients where conventional facemask therapy has limited skeletal effects. However, the skeletal effects of altering the location and direction of force from mini-implant-assisted maxillary protraction have not been extensively analyzed. In this study, the application of the novel N2 mini-implant as an orthopedic anchorage device is explored in its ability to treat patients with class III malocclusions. A 3D cranial mesh model with associated sutures was developed from CT images and Mimics modeling software. Utilizing ANSYS simulation software, protraction forces were applied at different locations and directions to simulate conventional facemask therapy and seven maxillary protraction protocols utilizing the novel N2 mini-implant. Stress distribution and displacement were analyzed. Video animations and superimpositions were created. By changing the vector of force and location of N2 mini-implant, the maxilla was displaced differentially. Varying degrees of forward, downward, and rotational movements were observed in each case. For brachyfacial patients, anterior micro-implant-supported protraction at -45° or intermaxillary class III elastics at -45° are recommended. For dolicofacial patients, either anterior micro-implants at -15° or an intermaxillary spring at +30° is recommended. For mesofacial patients with favorable vertical maxillary position, palatal micro-implants at -30° are recommended; anterior micro-implants at -30° are preferred for shallow bites. For patients with a severe mid-facial deficiency, intermaxillary class III elastics at -30° are most effective in promoting anterior growth of the maxilla. By varying the location of N2 mini-implants and vector of class III mechanics, clinicians can differentially alter the magnitude of forward, downward, and

  5. Mini-projects in Chemical Engineering Laboratory

    Directory of Open Access Journals (Sweden)

    Angeles Cancela

    2013-03-01

    Full Text Available Chemical engineering laboratory practices based in mini-projects were design and applied the students of forestry engineering in chemical subject. This way of practice reveals a more cooperative learning and a different style of experimentation. The stated goal was to design practices that motivate students and to enable them to develop different skills, including cross teamwork and communication. This paper describes how these practices were developed and the advantages and disadvantages of using this methodology of teaching.

  6. Characterization of a mini-channel heat exchanger for a heat pump system

    International Nuclear Information System (INIS)

    Arteconi, A; Giuliani, G; Tartuferi, M; Polonara, F

    2014-01-01

    In this paper a mini-channel aluminum heat exchanger used in a reversible heat pump is presented. Mini-channel finned heat exchangers are getting more and more interest for refrigeration systems, especially when compactness and low refrigerant charge are desired. Purpose of this paper was to characterize the mini-channel heat exchanger used as evaporator in terms of heat transfer performance and to study the refrigerant distribution in the manifold. The heat exchanger characterization was performed experimentally by means of a test rig built up for this purpose. It is composed of an air-to-air heat pump, air channels for the external and internal air circulation arranged in a closed loop, measurement sensors and an acquisition system. The overall heat transfer capacity was assessed. Moreover, in order to characterize the flow field of the refrigerant in the manifold of the heat exchanger, a numerical investigation of the fluid flow by means of CFD was performed. It was meant to evaluate the goodness of the present design and to identify possible solutions for the future improvement of the manifold design.

  7. Enhancing Application Performance Using Mini-Apps: Comparison of Hybrid Parallel Programming Paradigms

    Science.gov (United States)

    Lawson, Gary; Sosonkina, Masha; Baurle, Robert; Hammond, Dana

    2017-01-01

    In many fields, real-world applications for High Performance Computing have already been developed. For these applications to stay up-to-date, new parallel strategies must be explored to yield the best performance; however, restructuring or modifying a real-world application may be daunting depending on the size of the code. In this case, a mini-app may be employed to quickly explore such options without modifying the entire code. In this work, several mini-apps have been created to enhance a real-world application performance, namely the VULCAN code for complex flow analysis developed at the NASA Langley Research Center. These mini-apps explore hybrid parallel programming paradigms with Message Passing Interface (MPI) for distributed memory access and either Shared MPI (SMPI) or OpenMP for shared memory accesses. Performance testing shows that MPI+SMPI yields the best execution performance, while requiring the largest number of code changes. A maximum speedup of 23 was measured for MPI+SMPI, but only 11 was measured for MPI+OpenMP.

  8. A Cost-Effective Fluorescence Mini-Microscope with Adjustable Magnifications for Biomedical Applications

    Science.gov (United States)

    Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali

    2015-01-01

    We have designed and fabricated a miniature microscope from off-the-shelf components and webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters such as cell/tissue viability (e.g. Live/Dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60X, achieves a resolution as high as microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread applications in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required. PMID:26282117

  9. Critical factors for the success of orthodontic mini-implants: a systematic review.

    Science.gov (United States)

    Chen, Yan; Kyung, Hee Moon; Zhao, Wen Ting; Yu, Won Jae

    2009-03-01

    This systematic review was undertaken to discuss factors that affect mini-implants as direct and indirect orthodontic anchorage. The data were collected from electronic databases (Medline [Entrez PubMed], Embase, Web of Science, Cochrane Library, and All Evidence Based Medicine Reviews). Randomized clinical trials, prospective and retrospective clinical studies, and clinical trials concerning the properties, affective factors, and requirements of mini-implants were considered. The titles and abstracts that appeared to fulfill the initial selection criteria were collected by consensus, and the original articles were retrieved and evaluated with a methodologic checklist. A hand search of key orthodontic journals was performed to identify recent unindexed literature. The search strategy resulted in 596 articles. By screening titles and abstracts, 126 articles were identified. After the exclusion criteria were applied, 16 articles remained. The analyzed results of the literature were divided into 2 topics: placement-related and loading-related factors. Mini-implants are effective as anchorage, and their success depends on proper initial mechanical stability and loading quality and quantity.

  10. Report on a 2009 mini-demonstration of the ARG-US Radio Frequency Identification (RFID) system in transportation

    International Nuclear Information System (INIS)

    Tsai, H.; Chen, K.; Jusko, M.; Craig, B.; Liu, Y.

    2009-01-01

    The Packaging Certification Program (PCP) of the U.S. Department of Energy (DOE) Environmental Management (EM), Office of Packaging and Transportation (EM-14), has developed a radio frequency identification (RFID) tracking and monitoring system for the management of nuclear materials during storage and transportation. The system, developed by the PCP team at Argonne National Laboratory, consists of hardware (Mk-series sensor tags, fixed and handheld readers, form factor for multiple drum types, seal integrity sensors, and enhanced battery management), software (application programming interface, ARG-US software for local and remote/web applications, secure server and database management), and cellular/satellite communication interfaces for vehicle tracking and item monitoring during transport. The ability of the above system to provide accurate, real-time tracking and monitoring of the status of multiple, certified containers of nuclear materials has been successfully demonstrated in a week-long, 1,700-mile DEMO performed in April 2008. While the feedback from the approximately fifty (50) stakeholders who participated in and/or observed the DEMO progression were very positive and encouraging, two major areas of further improvements - system integration and web application enhancement - were identified in the post-DEMO evaluation. The principal purpose of the MiniDemo described in this report was to verify these two specific improvements. The MiniDemo was conducted on August 28, 2009. In terms of system integration, a hybrid communication interface - combining the RFID item-monitoring features and a commercial vehicle tracking system by Qualcomm - was developed and implemented. In the MiniDemo, the new integrated system worked well in reporting tag status and vehicle location accurately and promptly. There was no incompatibility of components. The robust commercial communication gear, as expected, helped improve system reliability. The MiniDemo confirmed that system

  11. Report on a 2009 mini-demonstration of the ARG-US Radio Frequency Identification (RFID) system in transportation.

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H.; Chen, K.; Jusko, M.; Craig, B.; Liu, Y.; Decision and Information Sciences

    2009-11-23

    The Packaging Certification Program (PCP) of the U.S. Department of Energy (DOE) Environmental Management (EM), Office of Packaging and Transportation (EM-14), has developed a radio frequency identification (RFID) tracking and monitoring system for the management of nuclear materials during storage and transportation. The system, developed by the PCP team at Argonne National Laboratory, consists of hardware (Mk-series sensor tags, fixed and handheld readers, form factor for multiple drum types, seal integrity sensors, and enhanced battery management), software (application programming interface, ARG-US software for local and remote/web applications, secure server and database management), and cellular/satellite communication interfaces for vehicle tracking and item monitoring during transport. The ability of the above system to provide accurate, real-time tracking and monitoring of the status of multiple, certified containers of nuclear materials has been successfully demonstrated in a week-long, 1,700-mile DEMO performed in April 2008. While the feedback from the approximately fifty (50) stakeholders who participated in and/or observed the DEMO progression were very positive and encouraging, two major areas of further improvements - system integration and web application enhancement - were identified in the post-DEMO evaluation. The principal purpose of the MiniDemo described in this report was to verify these two specific improvements. The MiniDemo was conducted on August 28, 2009. In terms of system integration, a hybrid communication interface - combining the RFID item-monitoring features and a commercial vehicle tracking system by Qualcomm - was developed and implemented. In the MiniDemo, the new integrated system worked well in reporting tag status and vehicle location accurately and promptly. There was no incompatibility of components. The robust commercial communication gear, as expected, helped improve system reliability. The MiniDemo confirmed that system

  12. Laser-Driven Mini-Thrusters

    International Nuclear Information System (INIS)

    Sterling, Enrique; Lin Jun; Sinko, John; Kodgis, Lisa; Porter, Simon; Pakhomov, Andrew V.; Larson, C. William; Mead, Franklin B. Jr.

    2006-01-01

    Laser-driven mini-thrusters were studied using Delrin registered and PVC (Delrin registered is a registered trademark of DuPont) as propellants. TEA CO2 laser (λ = 10.6 μm) was used as a driving laser. Coupling coefficients were deduced from two independent techniques: force-time curves measured with a piezoelectric sensor and ballistic pendulum. Time-resolved ICCD images of the expanding plasma and combustion products were analyzed in order to determine the main process that generates the thrust. The measurements were also performed in a nitrogen atmosphere in order to test the combustion effects on thrust. A pinhole transmission experiment was performed for the study of the cut-off time when the ablation/air breakdown plasma becomes opaque to the incoming laser pulse

  13. Laser-Driven Mini-Thrusters

    Science.gov (United States)

    Sterling, Enrique; Lin, Jun; Sinko, John; Kodgis, Lisa; Porter, Simon; Pakhomov, Andrew V.; Larson, C. William; Mead, Franklin B.

    2006-05-01

    Laser-driven mini-thrusters were studied using Delrin® and PVC (Delrin® is a registered trademark of DuPont) as propellants. TEA CO2 laser (λ = 10.6 μm) was used as a driving laser. Coupling coefficients were deduced from two independent techniques: force-time curves measured with a piezoelectric sensor and ballistic pendulum. Time-resolved ICCD images of the expanding plasma and combustion products were analyzed in order to determine the main process that generates the thrust. The measurements were also performed in a nitrogen atmosphere in order to test the combustion effects on thrust. A pinhole transmission experiment was performed for the study of the cut-off time when the ablation/air breakdown plasma becomes opaque to the incoming laser pulse.

  14. Usefulness of the Mini Nutritional Assessment (MNA) in predicting the nutritional status of people with mental disorders in Taiwan.

    Science.gov (United States)

    Tsai, Alan C; Chou, Yuan-Ti; Chang, Tsui-Lan

    2011-02-01

    The study was to evaluate the ability of the Mini Nutritional Assessment in predicting malnutrition in people with three subtypes of mental disorder (schizophrenia, major depression and bipolar disorder) in Taiwan. The study involved a convenience sample of 120 residents of psychiatric wards managed by a hospital in central Taiwan (52 with schizophrenia, 36 with major depression and 32 with bipolar disorder) classified according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria. A structured questionnaire elicited subjects' personal data, disease history and answers to questions in the Mini Nutritional Assessment. Serum and anthropometrical parameters were measured. Nutritional status was evaluated with a content-equivalent version of the Mini Nutritional Assessment (Taiwan version-1, T1). The Mini Nutritional Assessment-Taiwan version-1 was effective in assessing the nutritional status of people of all three subtypes of disorder. Nutritional statuses predicted with the Mini Nutritional Assessment-Taiwan version-1 agreed well with other nutritional indicators such as BMI, waist circumference and appetite status. According to the Mini Nutritional Assessment-Taiwan version-1, people with major depression were more likely to be at risk of undernutrition, whereas people with schizophrenia or bipolar disorder were more likely to be at risk of overnutrition. The Mini Nutritional Assessment-Taiwan version-1 can effectively grade both undernutrition and overnutrition of people with schizophrenia, major depression or bipolar disorder. The Mini Nutritional Assessment enables nurses to monitor emerging nutritional problems in people with psychiatric disorder without relying on subjective judgement. With proper intervention, it can help reduce nutrition-related chronic conditions in these individuals and save on healthcare cost. © 2011 Blackwell Publishing Ltd.

  15. Toward Solution of the MiniBooNE-LSND Anomalies

    International Nuclear Information System (INIS)

    Karagiorgi, G.

    2012-01-01

    The LSND experiment has observed an anomalous excess of ν ¯ e events in a ν ¯ μ beam which can be interpreted as two-neutrino ν ¯ μ →ν ¯ e oscillations at Δm 2 ∼1 eV 2 , suggesting new physics. The MiniBooNE experiment has ruled out the LSND two-neutrino oscillation interpretation by looking for corresponding flavor oscillations in a neutrino beam, and assuming CP and CPT conservation. However, it has observed an anomalous excess of ν e events at low energy, which, to date, remains unexplained. The two excess signatures are discussed within the context of light sterile neutrino oscillations, and are further confronted with the latest results from a MiniBooNE search for ν ¯ μ →ν ¯ e oscillations in an antineutrino beam. Alternative interpretations are also referenced, along with possible future experimental tests.

  16. Avaliação do torque para inserção, remoção e fratura de diferentes mini-implantes ortodônticos Evaluation of insertion, removal and fracture torques of different orthodontic mini-implants in bovine tibia cortex

    Directory of Open Access Journals (Sweden)

    Maria Fernanda Prates da Nova

    2008-10-01

    Full Text Available OBJETIVO: avaliar, em mini-implantes de diferentes dimensões, os seguintes fatores: (a torque de inserção, (b torque de remoção, (c torque de fratura, (d tensão cisalhante, (e tensão normal e (f tipo de fratura. METODOLOGIA: foram utilizados 20 mini-implantes autoperfurantes, 10 da marca SIN e 10 da Neodent com, respectivamente, 8 e 7mm de comprimento, todos com 1,6mm de diâmetro. Dos 10 mini-implantes de cada marca, 5 não possuíam perfil transmucoso e 5 tinham perfil de 2mm, formando 4 grupos: SIN sem perfil (SSP, SIN com perfil (SCP, Neodent sem perfil (NSP e Neodent com perfil (NCP. Todos os mini-implantes foram inseridos em cortical óssea e removidos com micromotor acoplado a um torquímetro. Os mini-implantes foram, também, submetidos ao ensaio de fratura. Os torques de inserção, remoção e fratura, assim como a tensão cisalhante e normal calculadas, foram comparados entre todos os grupos pela ANOVA. O tipo de fratura foi avaliado em microscópio eletrônico de varredura. RESULTADOS: verificou-se que o grupo NCP apresentou torque de inserção significativamente maior que os demais grupos, porém todos fraturaram durante a inserção (n = 2 ou remoção (n = 3. Não houve diferença entre os grupos para o torque de remoção. Para o grupo NSP, o torque de fratura foi significativamente menor do que todos os outros grupos. Todos os mini-implantes sofreram fratura do tipo dúctil. CONCLUSÃO: uma vez que não houve diferença na resistência mecânica de ambas as marcas, variando apenas a forma, conclui-se que a resistência à fratura pode ser afetada por esta variável.AIM: The purpose of this study was to evaluate mini-implants with different dimensions for the following factors: (a insertion torque, (b removal torque, (c fracture torque, (d shear tension, (e normal tension and (f type of fracture. METHODS: Twenty self-drilling mini-implants were used, 10 from SIN and 10 from Neodent, with 1.6mm in diameter and with 8 and 7

  17. MiniSipper: a new in situ water sampler for high-resolution, long-duration acid mine drainage monitoring.

    Science.gov (United States)

    Chapin, Thomas P; Todd, Andrew S

    2012-11-15

    Abandoned hard-rock mines can be a significant source of acid mine drainage (AMD) and toxic metal pollution to watersheds. In Colorado, USA, abandoned mines are often located in remote, high elevation areas that are snowbound for 7-8 months of the year. The difficulty in accessing these remote sites, especially during winter, creates challenging water sampling problems and major hydrologic and toxic metal loading events are often under sampled. Currently available automated water samplers are not well suited for sampling remote snowbound areas so the U.S. Geological Survey (USGS) has developed a new water sampler, the MiniSipper, to provide long-duration, high-resolution water sampling in remote areas. The MiniSipper is a small, portable sampler that uses gas bubbles to separate up to 250 five milliliter acidified samples in a long tubing coil. The MiniSipper operates for over 8 months unattended in water under snow/ice, reduces field work costs, and greatly increases sampling resolution, especially during inaccessible times. MiniSippers were deployed in support of an U.S. Environmental Protection Agency (EPA) project evaluating acid mine drainage inputs from the Pennsylvania Mine to the Snake River watershed in Summit County, CO, USA. MiniSipper metal results agree within 10% of EPA-USGS hand collected grab sample results. Our high-resolution results reveal very strong correlations (R(2)>0.9) between potentially toxic metals (Cd, Cu, and Zn) and specific conductivity at the Pennsylvania Mine site. The large number of samples collected by the MiniSipper over the entire water year provides a detailed look at the effects of major hydrologic events such as snowmelt runoff and rainstorms on metal loading from the Pennsylvania Mine. MiniSipper results will help guide EPA sampling strategy and remediation efforts in the Snake River watershed. Published by Elsevier B.V.

  18. MiniSipper: A new in situ water sampler for high-resolution, long-duration acid mine drainage monitoring

    Science.gov (United States)

    Chapin, Thomas P.; Todd, Andrew S.

    2012-01-01

    Abandoned hard-rock mines can be a significant source of acid mine drainage (AMD) and toxic metal pollution to watersheds. In Colorado, USA, abandoned mines are often located in remote, high elevation areas that are snowbound for 7–8 months of the year. The difficulty in accessing these remote sites, especially during winter, creates challenging water sampling problems and major hydrologic and toxic metal loading events are often under sampled. Currently available automated water samplers are not well suited for sampling remote snowbound areas so the U.S. Geological Survey (USGS) has developed a new water sampler, the MiniSipper, to provide long-duration, high-resolution water sampling in remote areas. The MiniSipper is a small, portable sampler that uses gas bubbles to separate up to 250 five milliliter acidified samples in a long tubing coil. The MiniSipper operates for over 8 months unattended in water under snow/ice, reduces field work costs, and greatly increases sampling resolution, especially during inaccessible times. MiniSippers were deployed in support of an U.S. Environmental Protection Agency (EPA) project evaluating acid mine drainage inputs from the Pennsylvania Mine to the Snake River watershed in Summit County, CO, USA. MiniSipper metal results agree within 10% of EPA-USGS hand collected grab sample results. Our high-resolution results reveal very strong correlations (R2 > 0.9) between potentially toxic metals (Cd, Cu, and Zn) and specific conductivity at the Pennsylvania Mine site. The large number of samples collected by the MiniSipper over the entire water year provides a detailed look at the effects of major hydrologic events such as snowmelt runoff and rainstorms on metal loading from the Pennsylvania Mine. MiniSipper results will help guide EPA sampling strategy and remediation efforts in the Snake River watershed.

  19. Training Changes Professionals’ Attitudes Towards Dual Diagnosis

    DEFF Research Database (Denmark)

    Pinderup, Pernille

    2016-01-01

    Studies have shown that mental health professionals in many cases have counterproductive attitudes towards patients with mental illnesses and comorbid substance use disorders (dual diagnosis). This is problematic because professionals’ attitudes are important for both the therapeutic alliance...... and treatment outcome. This study tested whether providing training in dual diagnosis treatment to mental health professionals will affect their attitudes positively. Twenty-one professionals completed a questionnaire on attitudes towards working with dual diagnosis (Comorbidity Problems Perceptions...... Questionnaire, CMPPQ) pre-training and post-training. Results showed that there was a significant positive change in total CMPPQ scores and a positive change in all six subscales of the CMPPQ following training, indicating that the training resulted in more positive attitudes. The study suggests that training...

  20. The ASTRI mini-array within the future Cherenkov Telescope Array

    Directory of Open Access Journals (Sweden)

    Vercellone Stefano

    2016-01-01

    Full Text Available The Cherenkov Telescope Array (CTA is a large collaborative effort aimed at the design and operation of an observatory dedicated to very high-energy gamma-ray astrophysics in the energy range from a few tens of GeV to above 100 TeV, which will yield about an order of magnitude improvement in sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS. Within this framework, the Italian National Institute for Astrophysics is leading the ASTRI project, whose main goals are the design and installation on Mt. Etna (Sicily of an end-to-end dual-mirror prototype of the CTA small size telescope (SST and the installation at the CTA Southern site of a dual-mirror SST mini-array composed of nine units with a relative distance of about 300 m. The innovative dual-mirror Schwarzschild-Couder optical solution adopted for the ASTRI Project allows us to substantially reduce the telescope plate-scale and, therefore, to adopt silicon photo-multipliers as light detectors. The ASTRI mini-array is a wider international effort. The mini-array, sensitive in the energy range 1–100 TeV and beyond with an angular resolution of a few arcmin and an energy resolution of about 10–15%, is well suited to study relatively bright sources (a few × 10−12 erg cm−2 s−1 at 10 TeV at very high energy. Prominent sources such as extreme blazars, nearby well-known BL Lac objects, Galactic pulsar wind nebulae, supernovae remnants, micro-quasars, and the Galactic Center can be observed in a previously unexplored energy range. The ASTRI mini-array will extend the current IACTs sensitivity well above a few tens of TeV and, at the same time, will allow us to compare our results on a few selected targets with those of current (HAWC and future high-altitude extensive air-shower detectors.