WorldWideScience

Sample records for positive expiratory pressure

  1. Interaction between intra-abdominal pressure and positive-end expiratory pressure

    Directory of Open Access Journals (Sweden)

    Jamili Anbar Torquato

    2009-02-01

    Full Text Available OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H2O. The measurements were repeated after placing a 5 kg weight on the patients' belly. RESULTS: After the addition of 5 kg to the patients' belly at zero Positive-End Expiratory Pressure, both intra-abdominal pressure (p<0.001 and plateau pressures (p=0.005 increased significantly. Increasing the Positive-End Expiratory Pressure levels from zero to 10 cm H2O without weight on the belly did not result in any increase in intra-abdominal pressure (p=0.165. However, plateau pressures increased significantly (p< 0.001. Increasing Positive-End Expiratory Pressure from zero to 10 cm H2O and adding 5 kg to the belly increased intra-abdominal pressure from 8.7 to 16.8 (p<0.001 and plateau pressure from 18.26 to 27.2 (p<0.001. Maintaining Positive-End Expiratory Pressure at 10 cm H2O and placing 5 kg on the belly increased intra-abdominal pressure from 12.3 +/- 1.7 to 16.8 +/- 1.7 (p<0.001 but did not increase plateau pressure (26.6+/-1.2 to 27.2 +/-1.1 -p=0.83. CONCLUSIONS: The addition of a 5kg weight onto the abdomen significantly increased both IAP and the airway plateau pressure, confirming that intra-abdominal hypertension elevates the plateau pressure. However, plateau pressure alone cannot be considered a good indicator for the detection of elevated intra-abdominal pressure in patients under mechanical ventilation using PEEP. In these patients, the intra-abdominal pressure must also be measured.

  2. The effect of positive end-expiratory pressure on pulse pressure ...

    African Journals Online (AJOL)

    The effect of positive end-expiratory pressure on pulse pressure variation. FJ Smith, M Geyser, I Schreuder, PJ Becker. Abstract. Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV). Design: An observational study. Setting: Operating theatres of a ...

  3. Effects of positive end-expiratory pressure on renal function.

    Science.gov (United States)

    Järnberg, P O; de Villota, E D; Eklund, J; Granberg, P O

    1978-01-01

    The effects were studied positive end-expiratory pressure (PEEP) on renal function in eight patients with acute respiratory failure, requiring mechanical ventilation. On application of PEEP + 10 cm H2O, central venous pressure increased, systolic blood pressure decreased, urine flow and PAH-clearance were reduced, while inulin clearance remained stable. There was a marked increase in fractional sodium reabsorption and a concurrent decrease in fractional osmolal excretion. Fractional free-water clearance and the ratio UOsm/POsm did change.

  4. Positive expiratory pressure - Common clinical applications and physiological effects.

    Science.gov (United States)

    Fagevik Olsén, Monika; Lannefors, Louise; Westerdahl, Elisabeth

    2015-03-01

    Breathing out against resistance, in order to achieve positive expiratory pressure (PEP), is applied by many patient groups. Pursed lips breathing and a variety of devices can be used to create the resistance giving the increased expiratory pressure. Effects on pulmonary outcomes have been discussed in several publications, but the expected underlying physiology of the effect is seldom discussed. The aim of this article is to describe the purpose, performance, clinical application and underlying physiology of PEP when it is used to increase lung volumes, decrease hyperinflation or improve airway clearance. In clinical practice, the instruction how to use an expiratory resistance is of major importance since it varies. Different breathing patterns during PEP increase or reduce expiratory flow, result in movement of EPP centrally or peripherally and can increase or decrease lung volume. It is therefore necessary to give the right instructions to obtain the desired effects. As the different PEP techniques are being used by diverse patient groups it is not possible to give standard instructions. Based on the information given in this article the instructions have to be adjusted to give the optimal effect. There is no consensus regarding optimal treatment frequency and number of cycles included in each treatment session and must also be individualized. In future research, more precise descriptions are needed about physiological aims and specific instructions of how the treatments have been performed to assure as good treatment quality as possible and to be able to evaluate and compare treatment effects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Effects of positive end-expiratory pressure on arthroscopic shoulder surgery under general anesthesia.

    Science.gov (United States)

    Ersoy, Ayşın; Çakırgöz, Mensure; Ervatan, Zekeriya; Kıran, Özlem; Türkmen, Aygen; Esenyel, Cem Zeki

    2016-01-01

    Our study is a prospective, randomized study on patients undergoing arthroscopic shoulder surgery in the beach-chair position to evaluate the effects of positive end-expiratory pressure (PEEP) on hemodynamic stability, providing a bloodless surgical field and surgical satisfaction. Fifty patients were divided into two groups. Group I (n=25) had zero end-expiratory pressure (ZEEP) administered under general anesthesia, and group II (n=25) had +5 PEEP administered. During surgery, intraarticular hemorrhage and surgical satisfaction were evaluated on a scale of 0-10. During surgery, at the 5th, 30th, 60th, and 90th minutes and at the end of surgery, heart rate, mean arterial pressure (MAP), and positive inspiratory pressure were recorded. At the end of the surgery, the amount of bleeding and duration of the operation were recorded. In group I, the duration of operation and amount of bleeding were found to be significantly greater than those in group II (pshoulder surgery in the beach-chair position reduces the amount of hemorrhage in the surgical field and thus increases surgical satisfaction without requiring the creation of controlled hypotension.

  6. Effects of recruitment maneuver and positive end-expiratory pressure on respiratory mechanics and transpulmonary pressure during laparoscopic surgery.

    Science.gov (United States)

    Cinnella, Gilda; Grasso, Salvatore; Spadaro, Savino; Rauseo, Michela; Mirabella, Lucia; Salatto, Potito; De Capraris, Antonella; Nappi, Luigi; Greco, Pantaleo; Dambrosio, Michele

    2013-01-01

    The authors tested the hypothesis that during laparoscopic surgery, Trendelenburg position and pneumoperitoneum may worsen chest wall elastance, concomitantly decreasing transpulmonary pressure, and that a protective ventilator strategy applied after pneumoperitoneum induction, by increasing transpulmonary pressure, would result in alveolar recruitment and improvement in respiratory mechanics and gas exchange. In 29 consecutive patients, a recruiting maneuver followed by positive end-expiratory pressure 5 cm H(2)O maintained until the end of surgery was applied after pneumoperitoneum induction. Respiratory mechanics, gas exchange, blood pressure, and cardiac index were measured before (T(BSL)) and after pneumoperitoneum with zero positive end-expiratory pressure (T(preOLS)), after recruitment with positive end-expiratory pressure (T(postOLS)), and after peritoneum desufflation with positive end-expiratory pressure (T(end)). Esophageal pressure was used for partitioning respiratory mechanics between lung and chest wall (data are mean ± SD): on T(preOLS), chest wall elastance (E(cw)) and elastance of the lung (E(L)) increased (8.2 ± 0.9 vs. 6.2 ± 1.2 cm H(2)O/L, respectively, on T(BSL); P = 0.00016; and 11.69 ± 1.68 vs. 9.61 ± 1.52 cm H(2)O/L on T(BSL); P = 0.0007). On T(postOLS), both chest wall elastance and E(L) decreased (5.2 ± 1.2 and 8.62 ± 1.03 cm H(2)O/L, respectively; P = 0.00015 vs. T(preOLS)), and Pao(2)/inspiratory oxygen fraction improved (491 ± 107 vs. 425 ± 97 on T(preOLS); P = 0.008) remaining stable thereafter. Recruited volume (the difference in lung volume for the same static airway pressure) was 194 ± 80 ml. Pplat(RS) remained stable while inspiratory transpulmonary pressure increased (11.65 + 1.37 cm H(2)O vs. 9.21 + 2.03 on T(preOLS); P = 0.007). All respiratory mechanics parameters remained stable after abdominal desufflation. Hemodynamic parameters remained stable throughout the study. In patients submitted to laparoscopic surgery in

  7. Short-term effects of positive expiratory airway pressure in patients being weaned from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Marcelo de Mello Rieder

    2009-05-01

    Full Text Available OBJECTIVE: To investigate the feasibility and the cardiorespiratory effects of using positive expiratory airway pressure, a physiotherapeutic tool, in comparison with a T-tube, to wean patients from mechanical ventilation. METHODS/DESIGN: A prospective, randomized, cross-over study. SETTING: Two intensive care units. PATIENTS AND INTERVENTIONS: We evaluated forty patients who met weaning criteria and had been mechanically-ventilated for more than 48 hours, mean age 59 years, including 23 males. All patients were submitted to the T-tube and Expiratory Positive Airway Pressure devices, at 7 cm H2O, during a 30-minute period. Cardiorespiratory variables including work of breathing, respiratory rate (rr, peripheral oxygen saturation (SpO2, heart rate (hr, systolic, diastolic and mean arterial pressures (SAP, DAP, MAP were measured in the first and thirtieth minutes. The condition was analyzed as an entire sample set (n=40 and was also divided into subconditions: chronic obstructive pulmonary disease (n=14 and non-chronic obstructive pulmonary disease (non- chronic obstructive pulmonary disease (n=26 categories. Comparisons were made using a t-test and Analysis of Variance. The level of significance was p < 0.05. RESULTS: Our data showed an increase in work of breathing in the first and thirtieth minutes in the EPAP condition (0.86+ 0.43 and 1.02+1.3 as compared with the T-tube condition (0.25+0.26 and 0.26+0.35 (p<0.05, verified by the flow-sensor monitor (values in J/L. No statistical differences were observed when comparing the Expiratory Positive Airway Pressure and T-tube conditions with regard to cardiorespiratory measurements. The same result was observed for both chronic obstructive pulmonary disease and non- chronic obstructive pulmonary disease subconditions. CONCLUSIONS: Our study demonstrated that, in weaning patients from mechanical ventilation, the use of a fixed level of Expiratory Positive Airway Pressure caused an increase in work of

  8. Pharmacologic Interventions to Improve Splanchnic Oxygenation During Ventilation with Positive End-Expiratory Pressure

    NARCIS (Netherlands)

    Fournell, A.; Scheeren, T. W. L.; Picker, O.; Schwarte, L. A.; Wolf, M; Bucher, HU; Rudin, M; VanHuffel, S; Wolf, U; Bruley, DF; Harrison, DK

    2012-01-01

    Mechanical ventilation with positive end-expiratory pressure (PEEP) is an indispensable tool in the management of respiratory failure to preserve or improve lung function and systemic oxygenation. However, PEEP per se may also, as has been shown in experimental animals, impair regional

  9. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model.

    Directory of Open Access Journals (Sweden)

    Laura A Cagle

    Full Text Available Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury.To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation.5-12 week-old female BALB/c mice (n = 85 were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg or high tidal volume (15 ml/kg with or without positive end-expiratory pressure and recruitment maneuvers.Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation.Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours and lung injury worsens with longer-term ventilation (4 hrs. Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide

  10. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model

    Science.gov (United States)

    Franzi, Lisa M.; Linderholm, Angela L.; Last, Jerold A.; Adams, Jason Y.; Harper, Richart W.

    2017-01-01

    Background Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury. Objectives To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation. Methods 5–12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers. Results Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation. Conclusions Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points

  11. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model.

    Science.gov (United States)

    Cagle, Laura A; Franzi, Lisa M; Linderholm, Angela L; Last, Jerold A; Adams, Jason Y; Harper, Richart W; Kenyon, Nicholas J

    2017-01-01

    Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury. To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation. 5-12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers. Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation. Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide the frequency

  12. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  13. Hyperinflation and intrinsic positive end-expiratory pressure: less room to breathe.

    Science.gov (United States)

    Krieger, Bruce P

    2009-01-01

    Clinically, the symptoms and limited exercise capabilities of patients with chronic obstructive pulmonary disease (COPD) correlate better with changes in lung volumes than with airflow measurements. The realization of the clinical importance of hyperinflation has been overshadowed for decades by the use of forced expiratory volume during 1 s (FEV(1)) and the ratio of the FEV(1) to the forced expiratory vital capacity (FEV(1)/FVC) to categorize the severity and progression of COPD. Hyperinflation is defined as an elevation in the end-expiratory lung volume or functional residual capacity. When severe hyperinflation encroaches upon inspiratory capacity and limits vital capacity, it results in elevated intrinsic positive end-expiratory pressure (PEEPi) that places the diaphragm at a mechanical disadvantage and increases the work of breathing. Severe hyperinflation is the major physiologic cause of the resulting hypercarbic respiratory failure and patients' inability to transition (i.e. wean) from mechanical ventilatory support to spontaneous breathing. This paper reviews the basic physiologic principles of hyperinflation and its clinical manifestations as demonstrated by PEEPi. Also reviewed are the adverse effects of hyperinflation and PEEPi in critically ill patients with COPD, and methods for minimizing or counterbalancing these effects. Copyright 2009 S. Karger AG, Basel.

  14. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial

    NARCIS (Netherlands)

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S.; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N. T.; Schultz, Marcus J.; Pelosi, Paolo; Kaczka, David W.; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications

  15. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  16. Lung-protective ventilation in intensive care unit and operation room : Tidal volume size, level of positive end-expiratory pressure and driving pressure

    NARCIS (Netherlands)

    Serpa Neto, A.

    2017-01-01

    Several investigations have shown independent associations between three ventilator settings – tidal volume size, positive end–expiratory pressure (PEEP) and driving pressure – and outcomes in patients with the acute respiratory distress syndrome (ARDS). There is an increasing notion that similar

  17. Positive expiratory pressure in patients with chronic obstructive pulmonary disease--a systematic review.

    Science.gov (United States)

    Fagevik Olsén, Monika; Westerdahl, Elisabeth

    2009-01-01

    Breathing exercises against a resistance during expiration are often used as treatment for patients with chronic obstructive pulmonary disease (COPD). Controversy still exists regarding the clinical application and efficacy. The aim of this systematic review was to determine the effects of chest physiotherapy techniques with positive expiratory pressure (PEP) for the prevention and treatment of pulmonary impairment in adults with COPD. The review was conducted on randomised, controlled clinical trials in which breathing exercises with positive expiratory pressure were compared with other chest physical therapy techniques or with no treatment, in adult patients with COPD. A computer-assisted literature search of available databases from 1970 to January 2008 was performed. Two reviewers extracted data independently and assessed the trials systematically with an instrument for measuring methodological quality. In total, 11 trials met the inclusion criteria, of which 5 reached an adequate level of internal validity. Several kinds of PEP techniques with a diversity of intensities and durations of treatment have been evaluated with different outcome measures and follow-up periods. Benefits of PEP were found in isolated outcome measures in separate studies with a follow-up period <1 month. Concerning long-term effects, the results are contradictory. Prior to widespread prescription of long-term PEP treatment, more research is required to establish the benefit of the technique in patients with COPD. (c) 2008 S. Karger AG, Basel.

  18. Nebulized hypertonic saline via positive expiratory pressure versus via jet nebulizer in patients with severe cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Connell, Oisin J

    2011-06-01

    Nebulized hypertonic saline is a highly effective therapy for patients with cystic fibrosis (CF), yet 10% of patients are intolerant of hypertonic saline administered via jet nebulizer. Positive expiratory pressure (PEP) nebulizers splint open the airways and offers a more controlled rate of nebulization.

  19. Deep breathing exercises with positive expiratory pressure in patients with multiple sclerosis - a randomized controlled trial.

    Science.gov (United States)

    Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva

    2016-11-01

    Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  20. Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices.

    Science.gov (United States)

    Fagevik Olsén, Monika; Carlsson, Maria; Olsén, Erik; Westerdahl, Elisabeth

    2015-10-01

    Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rüsch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. Copyright © 2015 by

  1. Positive end-expiratory pressure improves survival in a rodent model of cardiopulmonary resuscitation using high-dose epinephrine.

    LENUS (Irish Health Repository)

    McCaul, Conán

    2009-10-01

    Multiple interventions have been tested in models of cardiopulmonary resuscitation (CPR) to optimize drug use, chest compressions, and ventilation. None has studied the effects of positive end-expiratory pressure (PEEP) on outcome. We hypothesized that because PEEP can reverse pulmonary atelectasis, lower pulmonary vascular resistance, and potentially improve cardiac output, its use during CPR would increase survival.

  2. Improved oxygenation during standing performance of deep breathing exercises with positive expiratory pressure after cardiac surgery: A randomized controlled trial.

    Science.gov (United States)

    Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth

    2015-09-01

    Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.

  3. Effects of Inhaled Fenoterol and Positive End-Expiratory Pressure on the Respiratory Mechanics of Patients with Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Claude Guerin

    2005-01-01

    Full Text Available BACKGROUND: During acute ventilatory failure in patients with chronic obstructive pulmonary disease (COPD, applying external positive end-expiratory pressure (PEEPe will reopen small airways and, thus, may enhance peripheral deposition as well as the physiological effects of inhaled beta-2 agonists.

  4. Setting individualized positive end-expiratory pressure level with a positive end-expiratory pressure decrement trial after a recruitment maneuver improves oxygenation and lung mechanics during one-lung ventilation.

    Science.gov (United States)

    Ferrando, Carlos; Mugarra, Ana; Gutierrez, Andrea; Carbonell, Jose Antonio; García, Marisa; Soro, Marina; Tusman, Gerardo; Belda, Francisco Javier

    2014-03-01

    We investigated whether individualized positive end-expiratory pressure (PEEP) improves oxygenation, ventilation, and lung mechanics during one-lung ventilation compared with standardized PEEP. Thirty patients undergoing thoracic surgery were randomly allocated to the study or control group. Both groups received an alveolar recruitment maneuver at the beginning and end of one-lung ventilation. After the alveolar recruitment maneuver, the control group had their lungs ventilated with a 5 cm·H2O PEEP, while the study group had their lungs ventilated with an individualized PEEP level determined by a PEEP decrement trial. Arterial blood samples, lung mechanics, and volumetric capnography were recorded at multiple timepoints throughout the procedure. The individualized PEEP values in study group were higher than the standardized PEEP values (10 ± 2 vs 5 cm·H2O; P decrement trial than with a standardized 5 cm·H2O of PEEP.

  5. Lung recruitability is better estimated according to the Berlin definition of acute respiratory distress syndrome at standard 5 cm H2O rather than higher positive end-expiratory pressure: a retrospective cohort study.

    Science.gov (United States)

    Caironi, Pietro; Carlesso, Eleonora; Cressoni, Massimo; Chiumello, Davide; Moerer, Onner; Chiurazzi, Chiara; Brioni, Matteo; Bottino, Nicola; Lazzerini, Marco; Bugedo, Guillermo; Quintel, Michael; Ranieri, V Marco; Gattinoni, Luciano

    2015-04-01

    The Berlin definition of acute respiratory distress syndrome has introduced three classes of severity according to PaO2/FIO2 thresholds. The level of positive end-expiratory pressure applied may greatly affect PaO2/FIO2, thereby masking acute respiratory distress syndrome severity, which should reflect the underlying lung injury (lung edema and recruitability). We hypothesized that the assessment of acute respiratory distress syndrome severity at standardized low positive end-expiratory pressure may improve the association between the underlying lung injury, as detected by CT, and PaO2/FIO2-derived severity. Retrospective analysis. Four university hospitals (Italy, Germany, and Chile). One hundred forty-eight patients with acute lung injury or acute respiratory distress syndrome according to the American-European Consensus Conference criteria. Patients underwent a three-step ventilator protocol (at clinical, 5 cm H2O, or 15 cm H2O positive end-expiratory pressure). Whole-lung CT scans were obtained at 5 and 45 cm H2O airway pressure. Nine patients did not fulfill acute respiratory distress syndrome criteria of the novel Berlin definition. Patients were then classified according to PaO2/FIO2 assessed at clinical, 5 cm H2O, or 15 cm H2O positive end-expiratory pressure. At clinical positive end-expiratory pressure (11±3 cm H2O), patients with severe acute respiratory distress syndrome had a greater lung tissue weight and recruitability than patients with mild or moderate acute respiratory distress syndrome (pBerlin definition of acute respiratory distress syndrome assessed at 5 cm H2O allows a better evaluation of lung recruitability and edema than at higher positive end-expiratory pressure clinically set.

  6. Positive end-expiratory pressure increases pulmonary clearance of inhaled 99mTc-DTPA in nonsmokers but not in healthy smokers

    International Nuclear Information System (INIS)

    Nolop, K.B.; Braude, S.; Royston, D.; Maxwell, D.L.; Hughes, J.M.B.

    1987-01-01

    Positive end-expiratory pressure (PEEP) is widely used in the treatment of severe pulmonary oedema, although its effects on the clearance of water and small solutes from alveolus to blood are not well characterized. We studied the effect of the application of 10 cmH 2 O of PEEP on the flux of inhaled 99 mTc-diethylene-triamine-penta-acetic acid (DTPA) from lung to blood in six healthy smoking and six nonsmoking subjects. The rate of flux was corrected for possible changes in pulmonary blood volume during PEEP by use of an intravenous injection of 99m Tc-DTPA. The baseline clearance rate (K,%.min -1 ) for nonsmokers was 1.48±0.12 (mean±SE) and increased to 2.40±0.29 during PEEP (p<0.05). In contrast, the mean clearance rate for smokers was 3.26±0.82 at baseline and 3.03±0.82 during PEEP (p=NS). The application of positive end-expiratory pressure appears to increase alveolar solute flux in nonsmokers but not in smokers, suggesting that the pathway for solute clearance in smokers is governed by different rate-limiting steps to those of nonsmokers

  7. Effect of Training Frequency on Maximum Expiratory Pressure

    Science.gov (United States)

    Anand, Supraja; El-Bashiti, Nour; Sapienza, Christine

    2012-01-01

    Purpose: To determine the effects of expiratory muscle strength training (EMST) frequency on maximum expiratory pressure (MEP). Method: We assigned 12 healthy participants to 2 groups of training frequency (3 days per week and 5 days per week). They completed a 4-week training program on an EMST trainer (Aspire Products, LLC). MEP was the primary…

  8. Intraoperative and postoperative evaluation of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients

    Directory of Open Access Journals (Sweden)

    Ye-Qiu Li

    2016-01-01

    Full Text Available Objective: To evaluate intraoperative and postoperative condition of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients. Methods: A total of 176 cases of elderly patients (more than 60 years old receiving laparoscopic surgery in our hospital from July 2013 to July 2015 were selected as research subjects and randomly divided into observation group and control group, each group included 88 cases, control group received conventional ventilation strategy, observation group received low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy, and then levels of hemodynamic indexes, respiratory mechanical indexes, serology indexes and cerebral vessel related indexes, etc of two groups were compared. Results: Intraoperative and postoperative heart rate and mean arterial pressure levels of observation group were lower than those of control group, arterial partial pressure of oxygen and oxygenation index levels were higher than those of control group and differences had statistical significance (P<0.05; intraoperative APIP and Pplat values of observation group were lower than those of control group, Cs value was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative serum IL-8 and TNF-α levels of observation group were lower than those of control group, IL-10 level was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative PjvO2, SjvO2 and CjvO2 levels of observation group were higher than those of control group, Da-jvO2 level was lower than that of control group and differences had statistical significance (P<0.05. Conclusions: When elderly patients receive laparoscopic surgery, the use of low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy can stabilize hemodynamic

  9. Effects of respiratory rate, plateau pressure, and positive end-expiratory pressure on PaO2 oscillations after saline lavage.

    Science.gov (United States)

    Baumgardner, James E; Markstaller, Klaus; Pfeiffer, Birgit; Doebrich, Marcus; Otto, Cynthia M

    2002-12-15

    One of the proposed mechanisms of ventilator-associated lung injury is cyclic recruitment of atelectasis. Collapse of dependent lung regions with every breath should lead to large oscillations in PaO2 as shunt varies throughout the respiratory cycle. We placed a fluorescence-quenching PO2 probe in the brachiocephalic artery of six anesthetized rabbits after saline lavage. Using pressure-controlled ventilation with oxygen, ventilator settings were varied in random order over three levels of positive end-expiratory pressure (PEEP), respiratory rate (RR), and plateau pressure minus PEEP (Delta). Dependence of the amplitude of PaO2 oscillations on PEEP, RR, and Delta was modeled by multiple linear regression. Before lavage, arterial PO2 oscillations varied from 3 to 22 mm Hg. After lavage, arterial PO2 oscillations varied from 5 to 439 mm Hg. Response surfaces showed markedly nonlinear dependence of amplitude on PEEP, RR, and Delta. The large PaO2 oscillations observed provide evidence for cyclic recruitment in this model of lung injury. The important effect of RR on the magnitude of PaO2 oscillations suggests that the static behavior of atelectasis cannot be accurately extrapolated to predict dynamic behavior at realistic breathing frequencies.

  10. Chest physiotherapy with positive expiratory pressure breathing after abdominal and thoracic surgery: a systematic review.

    Science.gov (United States)

    Orman, J; Westerdahl, E

    2010-03-01

    A variety of chest physiotherapy techniques are used following abdominal and thoracic surgery to prevent or reduce post-operative complications. Breathing techniques with a positive expiratory pressure (PEP) are used to increase airway pressure and improve pulmonary function. No systematic review of the effects of PEP in surgery patients has been performed previously. The purpose of this systematic review was to determine the effect of PEP breathing after an open upper abdominal or thoracic surgery. A literature search of randomised-controlled trials (RCT) was performed in five databases. The trials included were systematically reviewed by two independent observers and critically assessed for methodological quality. We selected six RCT evaluating the PEP technique performed with a mechanical device in spontaneously breathing adult patients after abdominal or thoracic surgery via thoracotomy. The methodological quality score varied between 4 and 6 on the Physiotherapy Evidence Database score. The studies were published between 1979 and 1993. Only one of the included trials showed any positive effects of PEP compared to other breathing techniques. Today, there is scarce scientific evidence that PEP treatment is better than other physiotherapy breathing techniques in patients undergoing abdominal or thoracic surgery. There is a lack of studies investigating the effect of PEP over placebo or no physiotherapy treatment.

  11. Is increased positive end-expiratory pressure the culprit? Autoresuscitation in a 44-year-old man after prolonged cardiopulmonary resuscitation: a case report

    OpenAIRE

    Hagmann, Henning; Oelmann, Katrin; Stangl, Robert; Michels, Guido

    2016-01-01

    Background The phenomenon of autoresuscitation is rare, yet it is known to most emergency physicians. However, the pathophysiology of the delayed return of spontaneous circulation remains enigmatic. Among other causes hyperinflation of the lungs and excessively high positive end-expiratory pressure have been suggested, but reports including cardiopulmonary monitoring during cardiopulmonary resuscitation are scarce to support this hypothesis. Case presentation We report a case of autoresuscita...

  12. [A comparative study between inflation and deflation pressure-volume curve in determining the optimal positive end-expiratory pressure].

    Science.gov (United States)

    Gang, Li; Sun, Xiao-yi; Xu, Jin-quan; Zhang, Xin-li; Kou, Lu-xin; Jiang, Zhi-hong; Zhang, Lei

    2012-02-01

    To determine the optimal positive end-expiratory pressure (PEEP) according to inflation and deflation pressure-volume curve (P-V curve) in patients with acute respiratory distress syndrome (ARDS). ARDS models were reproduced in 20 dogs, and they were randomly divided into two groups. In both groups, Levenberg-Marquardt iterative algorithm was employed using software to explore parameters fitting with Boltzmann formula, by which the real inflection point of pressure (Pinf d) in deflation limb or lower inflection point pressure (PLip) in inflation limb on P-V curve were defined. For the control group (inflation curve) P-V curve of PLip + 2 cm H(2)O [1 cm H(2)O = 0.098 kPa] was applied as the best PEEP value. In the experimental group (deflation curve) the Pinf d was taken as the best PEEP value. The heart rate (HR), blood pressure (BP), fingertip pulse oxygen saturation [SpO(2)], static lung compliance (Cst), arterial partial pressure of oxygen [PaO(2)] and arterial partial pressure of carbon dioxide [PaCO(2)] were monitored at 0, 2, 6, 12, 24 and 48 hours. Oxygenation index increased significantly both in control and experimental groups. In experimental group, oxygenation index (mm Hg, 1 mm Hg = 0.133 kPa) of 12, 24 and 48 hours was respectively significantly higher than that of the control group (12 hours: 177.63 ± 8.94 vs. 165.60 ± 8.90, 24 hours: 194.19 ± 10.67 vs. 168.70 ± 10.60, 48 hours: 203.15 ± 13.21 vs. 171.26 ± 9.21, all P deflation P-V curve was better than that of inflation curve.

  13. Associations between positive end-expiratory pressure and outcome of patients without ARDS at onset of ventilation: a systematic review and meta-analysis of randomized controlled trials

    NARCIS (Netherlands)

    Serpa Neto, Ary; Filho, Roberto Rabello; Cherpanath, Thomas; Determann, Rogier; Dongelmans, Dave A.; Paulus, Frederique; Tuinman, Pieter Roel; Pelosi, Paolo; de Abreu, Marcelo Gama; Schultz, Marcus J.

    2016-01-01

    The aim of this investigation was to compare ventilation at different levels of positive end-expiratory pressure (PEEP) with regard to clinical important outcomes of intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) at onset of ventilation. Meta-analysis of

  14. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators.

    Directory of Open Access Journals (Sweden)

    Murray Hinder

    Full Text Available Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or 'rainout' from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators.To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode.Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected.Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from 'specific' (tube occluded to 'ambiguous' (Safety valve open. Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O.This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode.

  15. High altitude pulmonary edema and exercise at 4,400 meters on Mount McKinley. Effect of expiratory positive airway pressure.

    Science.gov (United States)

    Schoene, R B; Roach, R C; Hackett, P H; Harrison, G; Mills, W J

    1985-03-01

    Breathing against positive expiratory pressure has been used to improve gas exchange in many forms of pulmonary edema, and forced expiration against resistance during exercise has been advocated for climbing at high altitude as a method to optimize performance. To evaluate the effect of expiratory positive airway pressure (EPAP) on climbers with high altitude pulmonary edema (HAPE) and on exercise at high altitude, we studied four climbers with HAPE at rest and 13 healthy climbers during exercise on a bicycle ergometer at 4400 m. We measured minute ventilation (VI, L/min), arterial oxygen saturation (SaO2 percent), end-tidal carbon dioxide (PACO2, mm Hg), respiratory rate (RR), and heart rate (HR) during the last minute of a five minute interval at rest in the climbers with HAPE, and at rest, 300, and 600 kpm/minute workloads on a bicycle ergometer in the healthy subjects. The HAPE subjects demonstrated an increased SaO2 percent, no change in HR or VI, and a decrease in RR on EPAP as compared to control. In normal subjects, SaO2 percent, VI, and heart rate were significantly higher on EPAP 10 cm H2O than 0 cm H2O control (p less than 0.01, 0.01, and 0.05, respectively). The RR and PaCO2 were not significantly different. In summary, EPAP improves gas exchange in HAPE subjects at rest. The EPAP in normal subjects at high altitude resulted in a higher SaO2 percent at the expense of a higher VI and higher HR. These results suggest that the work of breathing is higher and the stroke volume lower on EPAP. The positive pressure mask may be an effective temporizing measure for victims of HAPE who cannot immediately go to a lower altitude.

  16. Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

    Science.gov (United States)

    Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio

    2014-09-01

    Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).

  17. Intratidal recruitment/derecruitment persists at low and moderate positive end-expiratory pressure in paediatric patients.

    Science.gov (United States)

    Wirth, Steffen; Artner, Lisa; Broß, Tobias; Lozano-Zahonero, Sara; Spaeth, Johannes; Schumann, Stefan

    2016-12-01

    In paediatric patients positive end-expiratory pressure (PEEP) is traditionally set lower than in adults. We investigated whether moderately higher PEEP improves respiratory mechanics and regional ventilation. Therefore, 40 children were mechanically ventilated with PEEP 2 and 5cmH 2 O. Volume-dependent compliance profiles were analysed as a measure of intratidal recruitment/derecruitment. Regional ventilation was assessed using electrical impedance tomography. Mean compliance was 17.9±9.9mLcmH 2 O -1 (PEEP 2cmH 2 O), and 19.0±10.9mLcmH 2 O -1 (PEEP 5 cmH 2 O, pventilation. In conclusion, mechanically ventilated paediatric patients undergo intratidal recruitment/derecruitment which occurs more prominently in younger than in older children. A PEEP of 5cmH 2 O does not fully prevent intratidal recruitment/derecruitment but homogenizes regional ventilation in comparison to 2cmH 2 O. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Differential Effects of Intraoperative Positive End-expiratory Pressure (PEEP) on Respiratory Outcome in Major Abdominal Surgery Versus Craniotomy

    DEFF Research Database (Denmark)

    de Jong, Myrthe A C; Ladha, Karim S; Melo, Marcos F Vidal

    2015-01-01

    OBJECTIVES: In this study, we examined whether (1) positive end-expiratory pressure (PEEP) has a protective effect on the risk of major postoperative respiratory complications in a cohort of patients undergoing major abdominal surgeries and craniotomies, and (2) the effect of PEEP is differed......: Within the entire study population (major abdominal surgeries and craniotomies), we found an association between application of PEEP ≥5 cmH2O and a decreased risk of postoperative respiratory complications compared with PEEP 5 cmH2O was associated with a significant lower...... undergoing major abdominal surgery. Our data suggest that default mechanical ventilator settings should include PEEP of 5-10 cmH2O during major abdominal surgery....

  19. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial.

    Science.gov (United States)

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N T; Schultz, Marcus J; Pelosi, Paolo; Kaczka, David W; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications when compared to low PEEP (0-2 cm H2O) approach without recruitment breaths. However, effects of intraoperative PEEP on lung compliance remain poorly understood. We hypothesized that higher PEEP leads to a dominance of intratidal overdistension, whereas lower PEEP results in intratidal recruitment/derecruitment (R/D). To test our hypothesis, we used the volume-dependent elastance index %E2, a respiratory parameter that allows for noninvasive and radiation-free assessment of dominant overdistension and intratidal R/D. We compared the incidence of intratidal R/D, linear expansion, and overdistension by means of %E2 in a subset of the PROVHILO cohort. In 36 patients from 2 participating centers of the PROVHILO trial, we calculated respiratory system elastance (E), resistance (R), and %E2, a surrogate parameter for intratidal overdistension (%E2 > 30%) and R/D (%E2 mechanical ventilation with protective tidal volumes in patients undergoing open abdominal surgery, lung recruitment followed by PEEP of 12 cm H2O decreased the incidence of intratidal R/D and did not worsen overdistension, when compared to PEEP ≤2 cm H2O.

  20. Effects of nasal positive expiratory pressure on dynamic hyperinflation and 6-minute walk test in patients with COPD.

    Science.gov (United States)

    Wibmer, Thomas; Rüdiger, Stefan; Heitner, Claudia; Kropf-Sanchen, Cornelia; Blanta, Ioanna; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-05-01

    Dynamic hyperinflation is an important target in the treatment of COPD. There is increasing evidence that positive expiratory pressure (PEP) could reduce dynamic hyperinflation during exercise. PEP application through a nasal mask and a flow resistance device might have the potential to be used during daily physical activities as an auxiliary strategy of ventilatory assistance. The aim of this study was to determine the effects of nasal PEP on lung volumes during physical exercise in patients with COPD. Twenty subjects (mean ± SD age 69.4 ± 6.4 years) with stable mild-to-severe COPD were randomized to undergo physical exercise with nasal PEP breathing, followed by physical exercise with habitual breathing, or vice versa. Physical exercise was induced by a standard 6-min walk test (6 MWT) protocol. PEP was applied by means of a silicone nasal mask loaded with a fixed-orifice flow resistor. Body plethysmography was performed immediately pre-exercise and post-exercise. Differences in mean pre- to post-exercise changes in total lung capacity (-0.63 ± 0.80 L, P = .002), functional residual capacity (-0.48 ± 0.86 L, P = .021), residual volume (-0.56 ± 0.75 L, P = .004), S(pO2) (-1.7 ± 3.4%, P = .041), and 6 MWT distance (-30.8 ± 30.0 m, P = .001) were statistically significant between the experimental and the control interventions. The use of flow-dependent expiratory pressure, applied with a nasal mask and a PEP device, might promote significant reduction of dynamic hyperinflation during walking exercise. Further studies are warranted addressing improvements in endurance performance under regular application of nasal PEP during physical activities.

  1. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  2. Positive end-expiratory pressure improves gas exchange and pulmonary mechanics during partial liquid ventilation.

    Science.gov (United States)

    Kirmse, M; Fujino, Y; Hess, D; Kacmarek, R M

    1998-11-01

    Partial liquid ventilation (PLV) with perflubron (PFB) has been proposed as an adjunct to the current therapies for the acute respiratory distress syndrome (ARDS). Because PFB has been also referred to as "liquid PEEP," distributing to the most gravity-dependent regions of the lung, less attention has been paid to the amount of applied positive end-expiratory pressure (PEEP). We hypothesized that higher PEEP levels than currently applied are needed to optimize gas exchange, and that the lower inflection point (LIP) of the pressure-volume curve could be used to estimate the amount of PEEP needed when the lung is filled with PFB. Lung injury was induced in 23 sheep by repeated lung lavage with warmed saline until the PaO2/FIO2 ratio fell below 150. Five sheep were used to investigate the change of the LIP when the lung was filled with PFB in increments of 5 ml/kg/body weight to a total of 30 ml/kg/body weight. To evaluate the impact of PEEP set at LIP +1 cm H2O we randomized an additional 15 sheep to three groups with different doses (7.5 ml, 15 ml, 30 ml/kg/body weight) of PFB. In random order a PEEP of 5 cm H2O or PEEP at LIP +1 cm H2O was applied. The LIP decreased with incremental filling of PFB to a minimum at 10 ml (p PFB shifts the LIP to the left, and that setting PEEP at LIP +1 cm H2O improves gas exchange at moderate to high doses of PFB.

  3. Comparison of intermittent positive pressure breathing and temporary positive expiratory pressure in patients with severe chronic obstructive pulmonary disease.

    Science.gov (United States)

    Nicolini, Antonello; Mollar, Elena; Grecchi, Bruna; Landucci, Norma

    2014-01-01

    Results supporting the use and the effectiveness of positive expiratory, pressure devices in chronic obstructive pulmonary disease (COPD) patients are still controversial, We have tested the hypothesis that adding TPEP or IPPB to standard pharmacological therapy may provide additional clinical benefit over, pharmacological therapy only in patients with severe COPD. Fourty-five patients were randomized in three groups: a group was treated; with IPPB,a group was treated with TPEP and a group with pharmacological; therapy alone (control group). Primary outcome measures included the measurement of scale or, questionnaire concerning dyspnea (MRC scale),dyspnea,cough, and, sputum (BCSS) and quality of life (COPD assessment test) (CAT). Secondary, outcome measures were respiratory function testing,arterial blood gas,analysis,and hematological examinations. Both patients in the IPPB group and in the TPEP group showed a significant, improvement in two of three tests (MRC,CAT) compared to the control, group.However,in the group comparison analysis for, the same variables between IPPB group and TPEP group we observed a, significant improvement in the IPPB group (P≤.05 for MRC and P≤.01 for, CAT). The difference of action of the two techniques are evident in the results of, pulmonary function testing: IPPB increases FVC, FEV1, and MIP; this reflects, its capacity to increase lung volume. Also TPEP increases FVC and FEV1 (less, than IPPB), but increases MEP, while decreasing total lung capacity and, residual volume. The two techniques (IPPB and TPEP) improves significantly dyspnea; quality of; life tools and lung function in patients with severe COPD. IPPB demonstrated a greater effectiveness to improve dyspnea and quality of life tools (MRC, CAT) than TPEP. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  4. [Clinical research of using optimal compliance to determine positive end-expiratory pressure].

    Science.gov (United States)

    Xu, Lei; Feng, Quan-sheng; Lian, Fu; Shao, Xin-hua; Li, Zhi-bo; Wang, Zhi-yong; Li, Jun

    2012-07-01

    To observe the availability and security of optimal compliance strategy to titrate the optimal positive end-expiratory pressure (PEEP), compared with quasi-static pressure-volume curve (P-V curve) traced by low-flow method. Fourteen patients received mechanical ventilation with acute respiratory distress syndrome (ARDS) admitted in intensive care unit (ICU) of Tianjin Third Central Hospital from November 2009 to December 2010 were divided into two groups(n = 7). The quasi-static P-V curve method and the optimal compliance titration were used to set the optimal PEEP respectively, repeated 3 times in a row. The optimal PEEP and the consistency of repeated experiments were compared between groups. The hemodynamic parameters, oxygenation index (OI), lung compliance (C), cytokines and pulmonary surfactant-associated protein D (SP-D) concentration in plasma before and 2, 4, and 6 hours after the experiment were observed in each group. (1) There were no significant differences in gender, age and severity of disease between two groups. (2)The optimal PEEP [cm H(2)O, 1 cm H(2)O=0.098 kPa] had no significant difference between quasi-static P-V curve method group and the optimal compliance titration group (11.53 ± 2.07 vs. 10.57 ± 0.87, P>0.05). The consistency of repeated experiments in quasi-static P-V curve method group was poor, the slope of the quasi-static P-V curve in repeated experiments showed downward tendency. The optimal PEEP was increasing in each measure. There was significant difference between the first and the third time (10.00 ± 1.58 vs. 12.80 ± 1.92, P vs. 93.71 ± 5.38, temperature: 38.05 ± 0.73 vs. 36.99 ± 1.02, IL-6: 144.84 ± 23.89 vs. 94.73 ± 5.91, TNF-α: 151.46 ± 46.00 vs. 89.86 ± 13.13, SP-D: 33.65 ± 8.66 vs. 16.63 ± 5.61, MAP: 85.47 ± 9.24 vs. 102.43 ± 8.38, CCI: 3.00 ± 0.48 vs. 3.81 ± 0.81, OI: 62.00 ± 21.45 vs. 103.40 ± 37.27, C: 32.10 ± 2.92 vs. 49.57 ± 7.18, all P safety and usability.

  5. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  6. Differing responses in right and left ventricular filling, loading and volumes during positive end-expiratory pressure

    International Nuclear Information System (INIS)

    Schulman, D.S.; Biondi, J.W.; Matthay, R.A.; Zaret, B.L.; Soufer, R.

    1989-01-01

    Using a combined hemodynamic and radionuclide technique, 20 patients with varied ventricular function were evaluated during positive end-expiratory pressure (PEEP) application. Left ventricular (LV) and right ventricular (RV) ejection fractions and cardiac output were measured, and ventricular volumes were derived. Seven patients (group 1) who had an increase in LV end-diastolic volume with PEEP and 13 patients (group 2) who had the more typical response, a decrease in LV end-diastolic volume with PEEP, were identified. Compared with group 2, group 1 patients had a higher incidence of coronary artery disease (5 of 7 vs 1 of 13, p less than 0.005) and lower cardiac output (3.9 +/- 1.6 vs 9.1 +/- 3.2 liters/min, p less than 0.005), LV ejection fraction (27 +/- 13 vs 51 +/- 21%, p less than 0.05), RV ejection fraction (15 +/- 6 vs 32 +/- 8%, p less than 0.005) and peak filling rate (1.32 +/- 0.43 vs 3.51 +/- 1.70 end-diastolic volumes/s, p less than 0.05). LV and RV volumes increased and peak filling rate decreased with PEEP in group 1, whereas in group 2 LV volume decreased and RV volume and peak filling rate remained unchanged. Using stepwise regression analysis, the change in LV volume with PEEP was related directly to baseline systemic vascular resistance and inversely to baseline blood pressure. Similarly, the change in peak filling rate with PEEP was inversely related to the change in RV end-diastolic volume. Thus, the hemodynamic response to PEEP is heterogeneous and may be related to LV ischemia

  7. Effects of positive end-expiratory pressure on intraoperative core temperature in patients undergoing posterior spine surgery: prospective randomised trial.

    Science.gov (United States)

    Seo, Hyungseok; Do Son, Je; Lee, Hyung-Chul; Oh, Hyung-Min; Jung, Chul-Woo; Park, Hee-Pyoung

    2018-03-01

    Objective Positive end-expiratory pressure (PEEP) causes carotid baroreceptor unloading, which leads to thermoregulatory peripheral vasoconstriction. However, the effects of PEEP on intraoperative thermoregulation in the prone position remain unknown. Methods Thirty-seven patients undergoing spine surgery in the prone position were assigned at random to receive either 10 cmH 2 O PEEP (Group P) or no PEEP (Group Z). The primary endpoint was core temperature 180 minutes after intubation. Secondary endpoints were delta core temperature (difference in core temperature between 180 minutes and immediately after tracheal intubation), incidence of intraoperative hypothermia (core temperature of peripheral vasoconstriction-related data. Results The median [interquartile range] core temperature 180 minutes after intubation was 36.1°C [35.9°C-36.2°C] and 36.0°C [35.9°C-36.4°C] in Groups Z and P, respectively. The delta core temperature and incidences of intraoperative hypothermia and peripheral vasoconstriction were not significantly different between the two groups. The peripheral vasoconstriction threshold (36.2°C±0.5°C vs. 36.7°C±0.6°C) was lower and the onset of peripheral vasoconstriction (66 [60-129] vs. 38 [28-70] minutes) was slower in Group Z than in Group P. Conclusions Intraoperative PEEP did not reduce the core temperature decrease in the prone position, although it resulted in an earlier onset and higher threshold of peripheral vasoconstriction.

  8. Effects of positive end expiratory pressure administration during non-invasive ventilation in patients affected by amyotrophic lateral sclerosis: A randomized crossover study.

    Science.gov (United States)

    Crescimanno, Grazia; Greco, Francesca; Arrisicato, Salvo; Morana, Noemi; Marrone, Oreste

    2016-10-01

    No studies have evaluated the impact of different settings of non-invasive ventilation (NIV) in patients affected by amyotrophic lateral sclerosis (ALS). We explored consequences of positive end-expiratory pressure (PEEP) application on effectiveness of ventilation, sleep architecture and heart rate variability (HRV) in patients with ALS naïve to ventilatory treatment. In two consecutive nights, 25 patients received in random order 0 or 4 cm H2 0 of PEEP during nocturnal NIV administration (Idea Ultra ResMed) with the same level of total positive inspiratory pressure. Polysomnographies were performed to evaluate sleep and NIV quality, as well as HRV. HRV was analyzed on 4-h periods and on 5-min segments of stable NREM sleep. We did not observe differences in gas exchanges during NIV with and without PEEP. Conversely, during PEEP application increases in leaks (41.4 ± 29.3% vs 31.0 ± 25.7%, P = 0.0007) and in autotriggerings (4.2 (IQR 1.3-10.0) vs 0.9 (IQR 0.0-3.0) events/h, P NIV was associated with worse NIV and sleep quality and with higher sympathetic activity. © 2016 Asian Pacific Society of Respirology.

  9. Intrinsic positive end-expiratory pressure during one-lung ventilation of patients with pulmonary hyperinflation. Influence of low respiratory rate with unchanged minute volume.

    Science.gov (United States)

    Szegedi, L L; Barvais, L; Sokolow, Y; Yernault, J C; d'Hollander, A A

    2002-01-01

    We measured lung mechanics and gas exchange during one-lung ventilation (OLV) of patients with chronic obstructive pulmonary disease, using three respiratory rates (RR) and unchanged minute volume. We studied 15 patients about to undergo lung surgery, during anaesthesia, and placed in the lateral position. Ventilation was with constant minute volume, inspiratory flow and FIO2. For periods of 15 min, RR of 5, 10, and 15 bpm were applied in a random sequence and recordings were made of lung mechanics and an arterial blood gas sample was taken. Data were analysed with the repeated measures ANOVA and paired t-test with Bonferroni correction. PaO2 changes were not significant. At the lowest RR, PaCO2 decreased (from 42 (SD 4) mm Hg at RR 15-41 (4) mm Hg at RR 10 and 39 (4) mm Hg at RR 5, P<0.01), and end-tidal carbon dioxide increased (from 33 (5) mm Hg at RR 15 to 35 (5) mm Hg at RR 10 and 36 (6) mm Hg at RR 5, P<0.01). Intrinsic positive end-expiratory pressure (PEEPi) was reduced even with larger tidal volumes (from 6 (4) cm H2O at RR 15-5 (4) cm H2O at RR 10, and 3 (3) cm H2O at RR 5, P<0.01), most probably caused by increased expiratory time at the lowest RR. A reduction in RR reduces PEEPi and hypercapnia during OLV in anaesthetized patients with chronic obstructive lung disease.

  10. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  11. Effect of nasal continuous and biphasic positive airway pressure on lung volume in preterm infants

    NARCIS (Netherlands)

    Miedema, Martijn; van der Burg, Pauline S.; Beuger, Sabine; de Jongh, Frans H.; Frerichs, Inez; van Kaam, Anton H.

    2013-01-01

    To monitor regional changes in end-expiratory lung volume (EELV), tidal volumes, and their ventilation distribution during different levels of nasal continuous positive airway pressure (nCPAP) and nasal biphasic positive airway pressure (BiPAP) in stable preterm infants. By using electrical

  12. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study.

    Science.gov (United States)

    Dahl, Michael K; Vistisen, Simon T; Koefoed-Nielsen, Jacob; Larsson, Anders

    2009-01-01

    Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH2O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (DeltaSV) following fluid loading. Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus DeltaSV showed the highest R2 (0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia

  13. Intraoperative protective mechanical ventilation for prevention of postoperative pulmonary complications: a comprehensive review of the role of tidal volume, positive end-expiratory pressure, and lung recruitment maneuvers.

    Science.gov (United States)

    Güldner, Andreas; Kiss, Thomas; Serpa Neto, Ary; Hemmes, Sabrine N T; Canet, Jaume; Spieth, Peter M; Rocco, Patricia R M; Schultz, Marcus J; Pelosi, Paolo; Gama de Abreu, Marcelo

    2015-09-01

    Postoperative pulmonary complications are associated with increased morbidity, length of hospital stay, and mortality after major surgery. Intraoperative lung-protective mechanical ventilation has the potential to reduce the incidence of postoperative pulmonary complications. This review discusses the relevant literature on definition and methods to predict the occurrence of postoperative pulmonary complication, the pathophysiology of ventilator-induced lung injury with emphasis on the noninjured lung, and protective ventilation strategies, including the respective roles of tidal volumes, positive end-expiratory pressure, and recruitment maneuvers. The authors propose an algorithm for protective intraoperative mechanical ventilation based on evidence from recent randomized controlled trials.

  14. Application of dead space fraction to titrate optimal positive end-expiratory pressure in an ARDS swine model.

    Science.gov (United States)

    Bian, Weishuai; Chen, Wei; Chao, Yangong; Wang, Lan; Li, Liming; Guan, Jian; Zang, Xuefeng; Zhen, Jie; Sheng, Bo; Zhu, Xi

    2017-04-01

    This study aimed to apply the dead space fraction [ratio of dead space to tidal volume (VD/VT)] to titrate the optimal positive end-expiratory pressure (PEEP) in a swine model of acute respiratory distress syndrome (ARDS). Twelve swine models of ARDS were constructed. A lung recruitment maneuver was then conducted and the PEEP was set at 20 cm H 2 O. The PEEP was reduced by 2 cm H 2 O every 10 min until 0 cm H 2 O was reached, and VD/VT was measured after each decrement step. VD/VT was measured using single-breath analysis of CO 2 , and calculated from arterial CO 2 partial pressure (PaCO 2 ) and mixed expired CO 2 (PeCO 2 ) using the following formula: VD/VT = (PaCO 2 - PeCO 2 )/PaCO 2 . The optimal PEEP was identified by the lowest VD/VT method. Respiration and hemodynamic parameters were recorded during the periods of pre-injury and injury, and at 4 and 2 cm H 2 O below and above the optimal PEEP (Po). The optimal PEEP in this study was found to be 13.25±1.36 cm H 2 O. During the Po period, VD/VT decreased to a lower value (0.44±0.08) compared with that during the injury period (0.68±0.10) (P<0.05), while the intrapulmonary shunt fraction reached its lowest value. In addition, a significant change of dynamic tidal respiratory compliance and oxygenation index was induced by PEEP titration. These results indicate that minimal VD/VT can be used for PEEP titration in ARDS.

  15. Static end-expiratory and dynamic forced expiratory tracheal collapse in COPD

    International Nuclear Information System (INIS)

    O'Donnell, C.R.; Bankier, A.A.; O'Donnell, D.H.; Loring, S.H.; Boiselle, P.M.

    2014-01-01

    Aim: To determine the range of tracheal collapse at end-expiration among chronic obstructive pulmonary disease (COPD) patients and to compare the extent of tracheal collapse between static end-expiratory and dynamic forced-expiratory multidetector-row computed tomography (MDCT). Materials and methods: After institutional review board approval and obtaining informed consent, 67 patients meeting the National Heart, Lung, and Blood Institute (NHLBI)/World Health Organization (WHO) Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for COPD were sequentially imaged using a 64-detector-row CT machine at end-inspiration, during forced expiration, and at end-expiration. Standardized respiratory coaching and spirometric monitoring were employed. Mean percentage tracheal collapse at end-expiration and forced expiration were compared using correlation analysis, and the power of end-expiratory cross-sectional area to predict excessive forced-expiratory tracheal collapse was computed following construction of receiver operating characteristic (ROC) curves. Results: Mean percentage expiratory collapse among COPD patients was 17 ± 18% at end-expiration compared to 62 ± 16% during forced expiration. Over the observed range of end-expiratory tracheal collapse (approximately 10–50%), the positive predictive value of end-expiratory collapse to predict excessive (≥80%) forced expiratory tracheal collapse was <0.3. Conclusion: COPD patients demonstrate a wide range of end-expiratory tracheal collapse. The magnitude of static end-expiratory tracheal collapse does not predict excessive dynamic expiratory tracheal collapse

  16. Value and limitations of transpulmonary pressure calculations during intra-abdominal hypertension.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Gard, Kenneth E; Adams, Alexander B; Faltesek, Katherine A; Anderson, Christopher P; Dries, David J; Marini, John J

    2013-08-01

    To clarify the effect of progressively increasing intra-abdominal pressure on esophageal pressure, transpulmonary pressure, and functional residual capacity. Controlled application of increased intra-abdominal pressure at two positive end-expiratory pressure levels (1 and 10 cm H2O) in an anesthetized porcine model of controlled ventilation. Large animal laboratory of a university-affiliated hospital. Eleven deeply anesthetized swine (weight 46.2 ± 6.2 kg). Air-regulated intra-abdominal hypertension (0-25 mm Hg). Esophageal pressure, tidal compliance, bladder pressure, and end-expiratory lung aeration by gas dilution. Functional residual capacity was significantly reduced by increasing intra-abdominal pressure at both positive end-expiratory pressure levels (p ≤ 0.0001) without corresponding changes of end-expiratory esophageal pressure. Above intra-abdominal pressure 5 mm Hg, plateau airway pressure increased linearly by ~ 50% of the applied intra-abdominal pressure value, associated with commensurate changes of esophageal pressure. With tidal volume held constant, negligible changes occurred in transpulmonary pressure due to intra-abdominal pressure. Driving pressures calculated from airway pressures alone (plateau airway pressure--positive end-expiratory pressure) did not equate to those computed from transpulmonary pressure (tidal changes in transpulmonary pressure). Increasing positive end-expiratory pressure shifted the predominantly negative end-expiratory transpulmonary pressure at positive end-expiratory pressure 1 cm H2O (mean -3.5 ± 0.4 cm H2O) into the positive range at positive end-expiratory pressure 10 cm H2O (mean 0.58 ± 1.2 cm H2O). Despite its insensitivity to changes in functional residual capacity, measuring transpulmonary pressure may be helpful in explaining how different levels of positive end-expiratory pressure influence recruitment and collapse during tidal ventilation in the presence of increased intra-abdominal pressure and in

  17. Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A

    1994-11-01

    To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle volumes changed as PEEP increased, but there were marked interpatient

  18. Hemodynamic differences between continual positive and two types of negative pressure ventilation.

    Science.gov (United States)

    Lockhat, D; Langleben, D; Zidulka, A

    1992-09-01

    In seven anesthetized dogs, ventilated with matching lung volumes, tidal volumes, and respiratory rates, we compared the effects on cardiac output (CO), arterial venous oxygen saturation difference (SaO2 - SVO2), and femoral and inferior vena cava pressure (1) intermittent positive pressure ventilation with positive end-expiratory pressure (CPPV); (2) iron-lung ventilation with negative end-expiratory pressure (ILV-NEEP); (3) grid and wrap ventilation with NEEP applied to the thorax and upper abdomen (G&W-NEEP). The values of CO and SaO2 - SVO2 with ILV-NEEP were similar to those with CPPV. However, with G&W-NEEP as compared with ILV-NEEP, mean CO was greater (2.9 versus 2.6 L/min, p = 0.02) and mean (SaO2 - SVO2) was lower (26.6% versus 28.3%, p = NS). Mean PFEM-IVC was higher with G&W-NEEP than with the other types of ventilation. We conclude that (1) ILV-NEEP is hemodynamically equivalent to CPPV and (2) G&W-NEEP has less adverse hemodynamic consequences. has less adverse hemodynamic consequences.

  19. Use of positive pressure in preoperative and intraoperative of bariatric surgery and its effect on the time of extubation

    Directory of Open Access Journals (Sweden)

    Letícia Baltieri

    2015-04-01

    Full Text Available BACKGROUND AND OBJECTIVE: To investigate the influence of intraoperative and preoperative positive pressure in the time of extubation in patients undergoing bariatric surgery. METHOD: Randomized clinical trial, in which 40 individuals with a body mass index between 40 and 55 kg/m2, age between 25 and 55 years, nonsmokers, underwent bariatric surgery type Roux-en-Y gastric bypass by laparotomy and with normal preoperative pulmonary function were randomized into the following groups: G-pre (n = 10: individuals who received treatment with noninvasive positive pressure before surgery for 1 h; G-intra (n = 10: individuals who received positive end-expiratory pressure of 10 cm H2O throughout the surgical procedure; and G-control (n = 20: not received any preoperative or intraoperative intervention. Following were recorded: time between induction of anesthesia and extubation, between the end of anesthesia and extubation, duration of mechanical ventilation, and time between extubation and discharge from the post-anesthetic recovery. RESULTS: There was no statistical difference between groups. However, when applied to the Cohen coefficient, the use of positive end-expiratory pressure of 10 cm H2O during surgery showed a large effect on the time between the end of anesthesia and extubation. About this same time, the treatment performed preoperatively showed moderate effect. CONCLUSION: The use of positive end-expiratory pressure of 10 cm H2O in the intraoperative and positive pressure preoperatively, influenced the time of extubation of patients undergoing bariatric surgery.

  20. Is increased positive end-expiratory pressure the culprit? Autoresuscitation in a 44-year-old man after prolonged cardiopulmonary resuscitation: a case report.

    Science.gov (United States)

    Hagmann, Henning; Oelmann, Katrin; Stangl, Robert; Michels, Guido

    2016-12-20

    The phenomenon of autoresuscitation is rare, yet it is known to most emergency physicians. However, the pathophysiology of the delayed return of spontaneous circulation remains enigmatic. Among other causes hyperinflation of the lungs and excessively high positive end-expiratory pressure have been suggested, but reports including cardiopulmonary monitoring during cardiopulmonary resuscitation are scarce to support this hypothesis. We report a case of autoresuscitation in a 44-year-old white man after 80 minutes of advanced cardiac life support accompanied by continuous capnometry and repeated evaluation by ultrasound and echocardiography. After prolonged cardiopulmonary resuscitation, refractory electromechanical dissociation on electrocardiogram and ventricular akinesis were recorded. In addition, a precipitous drop in end-tidal partial pressure of carbon dioxide was noted and cardiopulmonary resuscitation was discontinued. Five minutes after withdrawal of all supportive measures his breathing resumed and a perfusing rhythm ensued. Understanding the underlying pathophysiology of autoresuscitation is hampered by a lack of reports including extensive cardiopulmonary monitoring during cardiopulmonary resuscitation in a preclinical setting. In this case, continuous capnometry was combined with repetitive ultrasound evaluation, which ruled out most assumed causes of autoresuscitation. Our observation of a rapid decline in end-tidal partial pressure of carbon dioxide supports the hypothesis of increased intrathoracic pressure. Continuous capnometry can be performed easily during cardiopulmonary resuscitation, also in a preclinical setting. Knowledge of the pathophysiologic mechanisms may lead to facile interventions to be incorporated into cardiopulmonary resuscitation algorithms. A drop in end-tidal partial pressure of carbon dioxide, for example, might prompt disconnection of the ventilation to allow left ventricular filling. Further reports and research on this topic

  1. Influence of Positive End-Expiratory Pressure on Myocardial Strain Assessed by Speckle Tracking Echocardiography in Mechanically Ventilated Patients

    Directory of Open Access Journals (Sweden)

    Federico Franchi

    2013-01-01

    Full Text Available Purpose. The effects of mechanical ventilation (MV on speckle tracking echocardiography- (STE-derived variables are not elucidated. The aim of the study was to evaluate the effects of positive end-expiratory pressure (PEEP ventilation on 4-chamber longitudinal strain (LS analysis by STE. Methods. We studied 20 patients admitted to a mixed intensive care unit who required intubation for MV and PEEP titration due to hypoxia. STE was performed at three times: (T1 PEEP = 5 cmH2O; (T2 PEEP = 10 cmH2O; and (T3 PEEP = 15 cmH2O. STE analysis was performed offline using a dedicated software (XStrain MyLab 70 Xvision, Esaote. Results. Left peak atrial-longitudinal strain (LS was significantly reduced from T1 to T2 and from T2 to T3 (. Right peak atrial-LS and right ventricular-LS showed a significant reduction only at T3 (. Left ventricular-LS did not change significantly during titration of PEEP. Cardiac chambers’ volumes showed a significant reduction at higher levels of PEEP (. Conclusions. We demonstrated for the first time that incremental PEEP affects myocardial strain values obtained with STE in intubated critically ill patients. Whenever performing STE in mechanically ventilated patients, care must be taken when PEEP is higher than 10 cmH2O to avoid misinterpreting data and making erroneous decisions.

  2. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  3. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents pulmonary inflammation in patients without preexisting lung injury.

    Science.gov (United States)

    Wolthuis, Esther K; Choi, Goda; Dessing, Mark C; Bresser, Paul; Lutter, Rene; Dzoljic, Misa; van der Poll, Tom; Vroom, Margreeth B; Hollmann, Markus; Schultz, Marcus J

    2008-01-01

    Mechanical ventilation with high tidal volumes aggravates lung injury in patients with acute lung injury or acute respiratory distress syndrome. The authors sought to determine the effects of short-term mechanical ventilation on local inflammatory responses in patients without preexisting lung injury. Patients scheduled to undergo an elective surgical procedure (lasting > or = 5 h) were randomly assigned to mechanical ventilation with either higher tidal volumes of 12 ml/kg ideal body weight and no positive end-expiratory pressure (PEEP) or lower tidal volumes of 6 ml/kg and 10 cm H2O PEEP. After induction of anesthesia and 5 h thereafter, bronchoalveolar lavage fluid and/or blood was investigated for polymorphonuclear cell influx, changes in levels of inflammatory markers, and nucleosomes. Mechanical ventilation with lower tidal volumes and PEEP (n = 21) attenuated the increase of pulmonary levels of interleukin (IL)-8, myeloperoxidase, and elastase as seen with higher tidal volumes and no PEEP (n = 19). Only for myeloperoxidase, a difference was found between the two ventilation strategies after 5 h of mechanical ventilation (P volumes and PEEP may limit pulmonary inflammation in mechanically ventilated patients without preexisting lung injury. The specific contribution of both lower tidal volumes and PEEP on the protective effects of the lung should be further investigated.

  4. Relationship between pre-extubation positive endexpiratory pressure and oxygenation after coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Reijane Oliveira Lima

    2015-08-01

    Full Text Available Abstract Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective: The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods: A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32; Group B, 8 cmH2O (n=26; and Group C, 10 cmH2O (n=20. Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion: In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal.

  5. Pulmonary lesion induced by low and high positive end-expiratory pressure levels during protective ventilation in experimental acute lung injury.

    Science.gov (United States)

    Pássaro, Caroline P; Silva, Pedro L; Rzezinski, Andréia F; Abrantes, Simone; Santiago, Viviane R; Nardelli, Liliane; Santos, Raquel S; Barbosa, Carolina M L; Morales, Marcelo M; Zin, Walter A; Amato, Marcelo B P; Capelozzi, Vera L; Pelosi, Paolo; Rocco, Patricia R M

    2009-03-01

    To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Prospective, randomized, and controlled experimental study. University research laboratory. Wistar rats were randomly assigned to control (C) [saline (0.1 mL), intraperitoneally] and ALI [paraquat (15 mg/kg), intraperitoneally] groups. After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H2O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (DeltaP2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and DeltaP2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and DeltaP2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful.

  6. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects were positioned in a 30° lateral recumbent position, and a 2-kgf compression was applied. For expiratory rib cage compression, the rib cage was compressed unilaterally; for expiratory abdominal compression, the area directly above the navel was compressed. Tidal volume values were the actual measured values divided by body weight. [Results] Tidal volume values were as follows: at rest, 7.2 ± 1.7 mL/kg; during expiratory rib cage compression, 8.3 ± 2.1 mL/kg; during expiratory abdominal compression, 9.1 ± 2.2 mL/kg. There was a significant difference between the tidal volume during expiratory abdominal compression and that at rest. The tidal volume in expiratory rib cage compression was strongly correlated with that in expiratory abdominal compression. [Conclusion] These results indicate that expiratory abdominal compression may be an effective alternative to the manual breathing assist procedure.

  7. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    International Nuclear Information System (INIS)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F.; Conforto, F.; Calimici, R.; Salvi, A.; Matteucci, G.

    2007-01-01

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 ± 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H 2 O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  8. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    Energy Technology Data Exchange (ETDEWEB)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F. [Dept. of Radiology, S. Giovanni HS, Rome (Italy); Conforto, F.; Calimici, R.; Salvi, A. [Dept. of Anesthesiology, S. Giovanni HS, Rome (Italy); Matteucci, G. [Dept. of Pneumology, S. Giovanni HS, Rome (Italy)

    2007-06-15

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 {+-} 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 = hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H{sub 2}O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  9. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid in healthy individuals

    Directory of Open Access Journals (Sweden)

    Isabella Martins de Albuquerque

    Full Text Available ABSTRACT Objective: To evaluate the effects of positive expiratory pressure (PEP on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females with a mean age of 28.3 ± 5.4 years, a mean FEV1/FVC ratio of 0.89 ± 0.14, and a mean FEV1 of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA radioaerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels-10 cmH2O (n = 10, 15 cmH2O (n = 10, and 20 cmH2O (n = 10. The 99mTc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of 99mTc-DTPA was significantly shorter when PEP was applied-at 10 cmH2O (p = 0.044, 15 cmH2O (p = 0.044, and 20 cmH2O (p = 0.004-in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects.

  10. Influência da técnica de pressão expiratória positiva oscilante utilizando pressões expiratórias pré-determinadas na viscosidade e na transportabilidade do escarro em pacientes com bronquiectasia Influence that oscillating positive expiratory pressure using predetermined expiratory pressures has on the viscosity and transportability of sputum in patients with bronchiectasis

    Directory of Open Access Journals (Sweden)

    Ercy Mara Cipulo Ramos

    2009-12-01

    Full Text Available OBJETIVO: Verificar a efetividade da técnica de pressão expiratória positiva oscilante (PEPO utilizando pressões expiratórias pré-determinadas sobre a viscosidade e a transportabilidade do escarro em pacientes com bronquiectasia. MÉTODOS: Foram incluídos no estudo 15 pacientes estáveis com bronquiectasia (7 homens; média de idade = 53 ± 16 anos, submetidos a duas intervenções PEPO consecutivas, com 24 h de intervalo entre si, utilizando pressões expiratórias de 15 cmH2O (P15 e 25 cmH2O (P25. O protocolo consistiu de tosse voluntária; nova expectoração voluntária após 20 min, denominado tempo zero (T0; repouso de 10 min; e utilização da técnica em duas séries de 10 min (S1 e S2 de PEPO em P15 e P25, com intervalo de 10 min entre si. A viscosidade e transportabilidade do escarro foram avaliadas pela viscosimetria, velocidade relativa de transporte no palato de rã, deslocamento em máquina simuladora de tosse e ângulo de adesão. As amostras de escarro foram coletadas em T0, após S1 e após S2. Testes estatísticos específicos foram aplicados de acordo com a distribuição dos dados. RESULTADOS: Houve diminuição significante da viscosidade do escarro após S1 em P15 e após S2 em P25. Não houve diferenças significantes entre todas as amostras para a transportabilidade. CONCLUSÕES: Houve diminuição da viscosidade do escarro quando a PEPO foi realizada em P15 e P25, o que sugere que não seja necessário gerar alta pressão expiratória para obter o resultado desejado.OBJECTIVE: To determine the effectiveness of oscillating positive expiratory pressure (OPEP using predetermined expiratory pressures on the viscosity and transportability of sputum in patients with bronchiectasis. METHODS: The study involved 15 stable patients with bronchiectasis (7 males; mean age = 53 ± 16 years, submitted to two consecutive OPEP interventions, with a 24-h interval between the two, using positive expiratory pressures set at 15 cmH2O

  11. Deep breathing exercises with positive expiratory pressure at a higher rate improve oxygenation in the early period after cardiac surgery--a randomised controlled trial.

    Science.gov (United States)

    Urell, Charlotte; Emtner, Margareta; Hedenström, Hans; Tenling, Arne; Breidenskog, Marie; Westerdahl, Elisabeth

    2011-07-01

    In addition to early mobilisation, a variety of breathing exercises are used to prevent postoperative pulmonary complications after cardiac surgery. The optimal duration of the treatment is not well evaluated. The aim of this study was to determine the effect of 30 versus 10 deep breaths hourly, while awake, with positive expiratory pressure on oxygenation and pulmonary function the first days after cardiac surgery. A total of 181 patients, undergoing cardiac surgery, were randomised into a treatment group, performing 30 deep breaths hourly the first postoperative days, or into a control group performing 10 deep breaths hourly. The main outcome measurement arterial blood gases and the secondary outcome pulmonary function, evaluated with spirometry, were determined on the second postoperative day. Preoperatively, both study groups were similar in terms of age, SpO(2), forced expiratory volume in 1s and New York Heart Association classification. On the second postoperative day, arterial oxygen tension (PaO(2)) was 8.9 ± 1.7 kPa in the treatment group and 8.1 ± 1.4 kPa in the control group (p = 0.004). Arterial oxygen saturation (SaO(2)) was 92.7 ± 3.7% in the treatment group and 91.1 ± 3.8% in the control group (p = 0.016). There were no differences in measured lung function between the groups or in compliance to the breathing exercises. Compliance was 65% of possible breathing sessions. A significantly increased oxygenation was found in patients performing 30 deep breaths the first two postoperative days compared with control patients performing 10 deep breaths hourly. These results support the implementation of a higher rate of deep breathing exercises in the initial phase after cardiac surgery. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  12. Positive end expiratory pressure during one-lung ventilation: Selecting ideal patients and ventilator settings with the aim of improving arterial oxygenation

    Directory of Open Access Journals (Sweden)

    Hoftman Nir

    2011-01-01

    Full Text Available The efficacy of positive end-expiratory pressure (PEEP in treating intraoperative hypoxemia during one-lung ventilation (OLV remains in question given conflicting results of prior studies. This study aims to (1 evaluate the efficacy of PEEP during OLV, (2 assess the utility of preoperative predictors of response to PEEP, and (3 explore optimal intraoperative settings that would maximize the effects of PEEP on oxygenation. Forty-one thoracic surgery patients from a single tertiary care university center were prospectively enrolled in this observational study. After induction of general anesthesia, a double-lumen endotracheal tube was fiberoptically positioned and OLV initiated. Intraoperatively, PEEP = 5 and 10 cmH 2 O were sequentially applied to the ventilated lung during OLV. Arterial oxygenation, cardiovascular performance parameters, and proposed perioperative variables that could predict or enhance response to PEEP were analysed. T-test and c2 tests were utilized for continuous and categorical variables, respectively. Multivariate analyses were carried out using a classification tree model of binary recursive partitioning. PEEP improved arterial oxygenation by ≥20% in 29% of patients (n = 12 and failed to do so in 71% (n = 29; however, no cardiovascular impact was noted. Among the proposed clinical predictors, only intraoperative tidal volume per kilogram differed significantly between responders to PEEP and non-responders (mean 6.6 vs. 5.7 ml/kg, P = 0.013; no preoperative variable predicted response to PEEP. A multivariate analysis did not yield a clinically significant model for predicting PEEP responsiveness. PEEP improved oxygenation in a subset of patients; larger, although still protective tidal volumes favored a positive response to PEEP. No preoperative variables, however, could be identified as reliable predictors for PEEP responders.

  13. Sensitivity and specificity of hypopnoea detection using nasal pressure in the presence of a nasal expiratory resistive device (Provent®)

    International Nuclear Information System (INIS)

    Milne, Stephen; Amis, Terence C; Wheatley, John R; Kairaitis, Kristina

    2014-01-01

    Nasal expiratory resistive valves (Provent ® ) have been proposed as novel therapy for obstructive sleep apnea. We compared pressure measurements from a standard nasal pressure catheter used to assess nasal airflow during sleep with those from nasal expiratory resistive device with attached proprietary nasal pressure cannula. Nasal pressure cannula or Provent ® + proprietary nasal pressure cannula were attached to a bench model of human anterior nares and nasal passages, and pressure measured (P). Respiratory airflows generated by a subject breathing were applied to rear of model and airflow ( V-dot ) measured via pneumotachograph. Airflow amplitude (Δ V-dot ) was plotted against pressure amplitude (ΔP). Hypopnoea detection (<50% Δ V-dot ) sensitivity and specificity was tested by expressing ΔP in terms of two reference breaths: reference breath 1, Δ V-dot 0.55 L s −1  = 100%; and reference breath 2, Δ V-dot 0.45 L s −1  = 100%. ΔP/Δ V-dot relationships were linear for Δ V-dot  ≤ 0.55 L s −1 ; ΔP = 0.37ΔV + 0.16 (nasal pressure cannula), ΔP = 2.7ΔV + 0.12 (Provent ® + proprietary nasal pressure cannula); both R 2  > 0.65, p < 0.0001; p < 0.0001 for between slope difference). For nasal pressure cannula, specificity of hypopnoea detection differed between reference breaths one and two (80.2% and 40.0%, respectively), and Provent ® + proprietary nasal pressure cannula (30.3% and 74.2%, respectively). Quantification of airflow obstruction in the presence of Provent ® + proprietary nasal pressure cannula is greatly influenced by the reference breath chosen to determine a reduction in nasal airflow. Reported variability in therapeutic response to nasal expiratory resistive devices may relate to differences in measurement technique specificity used to quantify the severity of sleep disordered breathing. (paper)

  14. Respiratory effects of low versus high tidal volume with or without positive end-expiratory pressure in anesthetized dogs with healthy lungs.

    Science.gov (United States)

    De Monte, Valentina; Bufalari, Antonello; Grasso, Salvatore; Ferrulli, Fabienne; Crovace, Alberto Maria; Lacitignola, Luca; Staffieri, Francesco

    2018-05-01

    OBJECTIVE To evaluate the impact of 2 tidal volumes (T V s) with or without positive end-expiratory pressure (PEEP) on lung mechanics, aeration, and gas exchange in healthy anesthetized dogs. ANIMALS 40 mixed-breed dogs with healthy lungs. PROCEDURES Anesthetized dogs were randomly assigned to 4 groups (n = 10/group) with different ventilatory settings: T V of 8 mL/kg and PEEP of 0 cm H 2 O (low T V group), T V of 8 mL/kg and PEEP of 5 cm H 2 O (low T V plus PEEP group), T V of 15 mL/kg and PEEP of 0 cm H 2 O (high T V group), or T V of 15 mL/kg and PEEP of 5 cm H 2 O (high T V plus PEEP group). Expired CO 2 and respiratory rate were titrated on the basis of a predetermined stepwise protocol. Gas exchange, respiratory mechanics, and pulmonary aeration were evaluated by means of CT 30 minutes after starting mechanical ventilation at the assigned setting. RESULTS Partial pressures of arterial and expired CO 2 were higher in the low T V and low T V plus PEEP groups than in the high T V and high T V plus PEEP groups. Peak and plateau airway pressures were higher in the PEEP group than in the other groups. Static lung compliance was higher in the high T V plus PEEP group than in the low T V group. Relative percentages of atelectatic and poorly aerated lung were lower in the high T V plus PEEP group than in the other groups. Oxygenation was similar among groups. CONCLUSIONS AND CLINICAL RELEVANCE Differences in T V and PEEP application during mechanical ventilation may affect respiratory function in anesthetized dogs with healthy lungs. Ventilation with a T V of 15 mL/kg and PEEP of 5 cm H 2 O significantly improved lung compliance and reduced the amount of atelectatic and poorly aerated lung.

  15. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.

    Science.gov (United States)

    Uchiyama, Akinori; Chang, Cheng; Suzuki, Shinya; Mashimo, Takashi; Fujino, Yuji

    2009-08-01

    Although inspiratory assist of spontaneous breathing in intubated patients is common, expiratory assist functions have rarely been reported. Effective expiratory support (ES) could be used to compensate for endotracheal tube (ETT) resistance during spontaneous breathing. In this study, we examined the performance of a new system designed to provide both inspiratory support (IS) and ES during spontaneous breathing with the goal of reducing the effective resistance of the ETT. The ES system consisted of a ventilator demand valve and a computer-controlled piston cylinder, which aspirated gas from the respiratory circuit during the expiratory phase. The movement of the piston was synchronized with spontaneous breathing. We compared the pressures at the tip of the ETT and in the breathing circuit during spontaneous breathing through an ETT of internal diameter (ID) 5 mm with that of an ETT with ID 8 mm in nine healthy adult male volunteers. The ventilatory mode was set to maintain a continuous airway pressure of 0 cm H(2)O. Three ventilator settings (no support, IS only, and IS plus ES) were compared using ID 5 mm ETT. We monitored pressure in the breathing circuit (P(aw)), ETT tip pressure (P(tip)), and respiratory flow. The P(tip) of the ID 5 mm ETT showed a large negative deflection during inspiration and a positive deflection during expiration without support. IS alone did not improve the respiratory pattern through the small ETT. However, IS plus ES resulted in negative P(aw) during expiration in addition to positive deflection of P(aw) during inspiration, making the pressure characteristics of P(tip) similar to those of ID 8 mm ETT. Moreover, IS plus ES produced a respiratory pattern through the ID 5 mm ETT that was similar to that through the ID 8 mm ETT. In this study of healthy volunteers, IS plus ES compensated for the airway resistance imposed by a ID 5.0 mm ETT to create pressure changes at the tip of the ETT similar to those of an ID 8.0 mm ETT.

  16. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    Science.gov (United States)

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  17. Combined Effects of Ventilation Mode and Positive End-Expiratory Pressure on Mechanics, Gas Exchange and the Epithelium in Mice with Acute Lung Injury

    Science.gov (United States)

    Thammanomai, Apiradee; Hamakawa, Hiroshi; Bartolák-Suki, Erzsébet; Suki, Béla

    2013-01-01

    The accepted protocol to ventilate patients with acute lung injury is to use low tidal volume (VT) in combination with recruitment maneuvers or positive end-expiratory pressure (PEEP). However, an important aspect of mechanical ventilation has not been considered: the combined effects of PEEP and ventilation modes on the integrity of the epithelium. Additionally, it is implicitly assumed that the best PEEP-VT combination also protects the epithelium. We aimed to investigate the effects of ventilation mode and PEEP on respiratory mechanics, peak airway pressures and gas exchange as well as on lung surfactant and epithelial cell integrity in mice with acute lung injury. HCl-injured mice were ventilated at PEEPs of 3 and 6 cmH2O with conventional ventilation (CV), CV with intermittent large breaths (CVLB) to promote recruitment, and a new mode, variable ventilation, optimized for mice (VVN). Mechanics and gas exchange were measured during ventilation and surfactant protein (SP)-B, proSP-B and E-cadherin levels were determined from lavage and lung homogenate. PEEP had a significant effect on mechanics, gas exchange and the epithelium. The higher PEEP reduced lung collapse and improved mechanics and gas exchange but it also down regulated surfactant release and production and increased epithelial cell injury. While CVLB was better than CV, VVN outperformed CVLB in recruitment, reduced epithelial injury and, via a dynamic mechanotransduction, it also triggered increased release and production of surfactant. For long-term outcome, selection of optimal PEEP and ventilation mode may be based on balancing lung physiology with epithelial injury. PMID:23326543

  18. Low tidal volume and high positive end-expiratory pressure mechanical ventilation results in increased inflammation and ventilator-associated lung injury in normal lungs.

    Science.gov (United States)

    Hong, Caron M; Xu, Da-Zhong; Lu, Qi; Cheng, Yunhui; Pisarenko, Vadim; Doucet, Danielle; Brown, Margaret; Aisner, Seena; Zhang, Chunxiang; Deitch, Edwin A; Delphin, Ellise

    2010-06-01

    Protective mechanical ventilation with low tidal volume (Vt) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes. We performed an animal study comparing 3 ventilation strategies used in the operating room in normal lungs. We compared the effects on pulmonary mechanics, inflammatory mediators, and lung tissue injury. Female pigs were randomized into 3 groups. Group H-Vt/3 (n = 6) was ventilated with a Vt of 15 mL/kg predicted body weight (PBW)/positive end-expiratory pressure (PEEP) of 3 cm H(2)O, group L-Vt/3 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 3 cm H(2)O, and group L-Vt/10 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 10 cm H(2)O, for 8 hours. Hemodynamics, airway mechanics, arterial blood gases, and inflammatory markers were monitored. Bronchoalveolar lavage (BAL) was analyzed for inflammatory markers and protein concentration. The right lower lobe was assayed for mRNA of specific cytokines. The right lower lobe and right upper lobe were evaluated histologically. In contrast to groups H-Vt/3 and L-Vt/3, group L-Vt/10 exhibited a 6-fold increase in inflammatory mediators in BAL (P ventilation with high PEEP resulted in increased production of inflammatory markers. Low PEEP resulted in lower levels of inflammatory markers. High Vt/low PEEP resulted in less histologic lung injury.

  19. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-{sup 99m}-labeled diethylenetriaminepentaacetic acid in healthy individuals

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, Isabella Martins de, E-mail: albuisa@gmail.com [Universidade Federal de Santa Maria (UFSM), Santa Maria, RS (Brazil). Departamento de Fisioterapia e Reabilitacao; Cardoso, Dannuey Machado; Paiva, Dulciane Nunes [Universidade de Santa Cruz do Sul, RS (Brazil); Masiero, Paulo Ricardo; Menna-Barreto, Sergio Saldanha [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre (Brazil); Resqueti, Vanessa Regiane; Fregonezi, Guilherme Augusto de Freitas [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2016-11-15

    Objective: To evaluate the effects of positive expiratory pressure (PEP) on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females) with a mean age of 28.3 ± 5.4 years, a mean FEV{sub 1}/FVC ratio of 0.89 ± 0.14, and a mean FEV{sub 1} of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m labeled diethylenetriaminepentaacetic acid ({sup 99m}TcDTPA) radio aerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels—10 cmH{sub 2}O (n = 10), 15 cmH{sub 2}O (n = 10), and 20 cmH{sub 2}O (n = 10). The {sup 99m}Tc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of {sup 99m}Tc-DTPA was significantly shorter when PEP was applied—at 10 cmH{sub 2}O (p = 0.044), 15 cmH{sub 2}O (p = 0.044), and 20 cmH{sub 2}O (p = 0.004) - in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects. (author)

  20. Physiological techniques for detecting expiratory flow limitation during tidal breathing

    Directory of Open Access Journals (Sweden)

    N.G. Koulouris

    2011-09-01

    Full Text Available Patients with severe chronic obstructive pulmonary disease (COPD often exhale along the same flow–volume curve during quiet breathing as they do during the forced expiratory vital capacity manoeuvre, and this has been taken as an indicator of expiratory flow limitation at rest (EFLT. Therefore, EFLT, namely attainment of maximal expiratory flow during tidal expiration, occurs when an increase in transpulmonary pressure causes no increase in expiratory flow. EFLT leads to small airway injury and promotes dynamic pulmonary hyperinflation, with concurrent dyspnoea and exercise limitation. In fact, EFLT occurs commonly in COPD patients (mainly in Global Initiative for Chronic Obstructive Lung Disease III and IV stage, in whom the latter symptoms are common, but is not exclusive to COPD, since it can also be detected in other pulmonary and nonpulmonary diseases like asthma, acute respiratory distress syndrome, heart failure and obesity, etc. The existing up to date physiological techniques of assessing EFLT are reviewed in the present work. Among the currently available techniques, the negative expiratory pressure has been validated in a wide variety of settings and disorders. Consequently, it should be regarded as a simple, noninvasive, practical and accurate new technique.

  1. Is there an optimal level of positive expiratory pressure (PEP) to improve walking tolerance in patients with severe COPD?

    Science.gov (United States)

    Russo, Davide; Simonelli, Carla; Paneroni, Mara; Saleri, Manuela; Piroddi, Ines Maria Grazia; Cardinale, Francesco; Vitacca, Michele; Nicolini, Antonello

    2016-07-01

    The application of positive expiratory pressure (PEP) devices during exercise had been proposed in order to counteract the pulmonary hyperinflation, reduce the dyspnea and thus increase the exercise tolerance in patients with severe chronic obstructive pulmonary disease (COPD). This randomized controlled crossover trial investigated the effect of two different levels of PEP (1 cmH2O and 10 cmH2O) on distance covered at 6minute walk test (6MWT) in patients with severe COPD. Secondary outcomes were the evaluation of PEP effects on physiological and pulmonary function variables. Seventy-two severe COPD patients, referred to our hospitals as in and out patients, were recruited. A basal 6MWT without devices was performed on the first day, and then repeated with PEP 1 cmH2O (PEP1) and 10 cmH2O (PEP10), with a randomized crossover design. Slow and forced spirometries, including the inspiratory capacity measure, were repeated before and after each 6MWT. 50 patients (average age 69,92 year, mean FEV1 41,42% of predicted) concluded the trial. The 6MWT improved significantly among both PEP levels and baseline (323,8 mt at baseline vs. 337,8 PEP1 and 341,8 PEP10; p<.002 and p<.018, respectively). The difference between PEP10 and PEP1 did not reach the significance. No improvements were found in pulmonary function, symptoms and physiological variables after the 6MWT. In patients with severe COPD, the application of 1 cmH2O of PEP seems to improve the exercise tolerance as 10 cmH2O, with similar dyspnea. Further studies should investigate the effects of low levels of PEP on aerobic training programs. Copyright © 2016 SEPAR. Published by Elsevier Espana. All rights reserved.

  2. Severe bronchopulmonary dysplasia improved by noninvasive positive pressure ventilation: a case report

    Directory of Open Access Journals (Sweden)

    Mann Christian

    2011-09-01

    Full Text Available Abstract Introduction This is the first report to describe the feasibility and effectiveness of noninvasive positive pressure ventilation in the secondary treatment of bronchopulmonary dysplasia. Case presentation A former male preterm of Caucasian ethnicity delivered at 29 weeks gestation developed severe bronchopulmonary dysplasia. At the age of six months he was in permanent tachypnea and dyspnea and in need of 100% oxygen with a flow of 2.0 L/minute via a nasal cannula. Intermittent nocturnal noninvasive positive pressure ventilation was then administered for seven hours daily. The ventilator was set at a positive end-expiratory pressure of 6 cmH2O, with pressure support of 4 cmH2O, trigger at 1.4 mL/second, and a maximum inspiratory time of 0.7 seconds. Over the course of seven weeks, the patient's maximum daytime fraction of inspired oxygen via nasal cannula decreased from 1.0 to 0.75, his respiratory rate from 64 breaths/minute to 50 breaths/minute and carbon dioxide from 58 mmHg to 44 mmHg. Conclusion Noninvasive positive pressure ventilation may be a novel therapeutic option for established severe bronchopulmonary dysplasia. In the case presented, noninvasive positive pressure ventilation achieved sustained improvement in ventilation and thus prepared our patient for safe home oxygen therapy.

  3. Positive expiratory pressure therapy versus other airway clearance techniques for bronchiectasis.

    Science.gov (United States)

    Lee, Annemarie L; Burge, Angela T; Holland, Anne E

    2017-09-27

    People with bronchiectasis experience chronic cough and sputum production and require the prescription of airway clearance techniques (ACTs). A common type of ACT prescribed is positive expiratory pressure (PEP) therapy. A previous review has suggested that ACTs including PEP therapy are beneficial compared to no treatment in people with bronchiectasis. However, the efficacy of PEP therapy in a stable clinical state or during an acute exacerbation compared to other ACTs in bronchiectasis is unknown. The primary aim of this review was to determine the effects of PEP therapy compared with other ACTs on health-related quality of life (HRQOL), rate of acute exacerbations, and incidence of hospitalisation in individuals with stable or an acute exacerbation of bronchiectasis.Secondary aims included determining the effects of PEP therapy upon physiological outcomes and clinical signs and symptoms compared with other ACTs in individuals with stable or an acute exacerbation of bronchiectasis. We searched the Cochrane Airways Group Specialised Register of Trials, PEDro and clinical trials registries from inception to February 2017 and we handsearched relevant journals. Randomised controlled parallel and cross-over trials that compared PEP therapy versus other ACTs in participants with bronchiectasis. We used standard methodological procedures as outlined by Cochrane. Nine studies involving 213 participants met the inclusion criteria, of which seven were cross-over in design. All studies included adults with bronchiectasis, with eight including participants in a stable clinical state and one including participants experiencing an acute exacerbation. Eight studies used oscillatory PEP therapy, using either a Flutter or Acapella device and one study used Minimal PEP therapy. The comparison intervention differed between studies. The methodological quality of studies was poor, with cross-over studies including suboptimal or no washout period, and a lack of blinding of

  4. [The influence of positive end-expiratory pressure on cerebral blood flow and cerebrovascular autoregulation in patients with acute respiratory distress syndrome].

    Science.gov (United States)

    Yang, Chunli; Chen, Zhi; Lu, Yuanhua; He, Huiwei; Zeng, Weihua

    2014-05-01

    To explore the influence of different positive end-expiratory pressure (PEEP) levels on cerebral blood flow (CBF) and cerebrovascular autoregulation in patients with acute respiratory distress syndrome(ARDS). A prospective study was conducted. Moderate or severe ARDS patients admitted to Department of Critical Care Medicine of Jiangxi Provincial People's Hospital from January 1st, 2013 to October 1st, 2013 were enrolled. The changes in hemodynamics, respiratory mechanics and gas exchange under different levels of PEEP were observed. CBF velocity of middle cerebral artery (MCA) was measured using transcranial Doppler (TCD), and breath-holding index (BHI) was also calculated. 35 patients with ARDS were included. The oxygenation index (OI), peak inspiratory pressure (PIP), plat pressure (Pplat) and central venous pressure (CVP) were markedly elevated (OI: 324.7±117.2 mmHg vs. 173.4±95.8 mmHg, t=5.913, P=0.000; PIP: 34.7±9.1 cmH2O vs. 26.1±7.9 cmH2O,t=4.222, P=0.000; Pplat: 30.5±8.4 cmH2O vs. 22.2±7.1 cmH2O, t=4.465, P=0.000; CVP: 12.1±3.5 mmHg vs. 8.8±2.2 mmHg, t=4.723, P=0.000) when PEEP was increased from (6.4±1.0) cmH2O to (14.5±2.0) cmH2O (1 cmH2O=0.098 kPa). But no significant difference in the heart rate (85.5±19.1 beats/min vs. 82.7±17.3 beats/min, t=0.643, P=0.523), mean arterial pressure (73.5±12.4 mmHg vs. 76.4±15.1 mmHg, t=0.878, P=0.383) and CBF velocity of MCA [peak systolic flow velocity (Vmax): 91.26±17.57 cm/s vs. 96.64±18.71 cm/s, t=1.240, P=0.219; diastolic flow velocity (Vmin): 31.54±7.71 cm/s vs. 33.87±8.53 cm/s, t=1.199, P=0.235; mean velocity (Vmean): 51.19±12.05 cm/s vs. 54.27±13.36 cm/s, t=1.013, P=0.315] was found. 18 patients with BHI<0.1 at baseline demonstrated that cerebral vasomotor reactivity was poor. BHI was slightly decreased with increase in PEEP (0.78±0.16 vs. 0.86±0.19, t=1.905, P=0.061). Some of moderate or severe ARDS patients without central nervous system disease have independent of preexisting cerebral

  5. Impact of expiratory strength training in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Plowman, Emily K; Watts, Stephanie A; Tabor, Lauren; Robison, Raele; Gaziano, Joy; Domer, Amanda S; Richter, Joel; Vu, Tuan; Gooch, Clifton

    2016-06-01

    We evaluated the feasibility and impact of expiratory muscle strength training (EMST) on respiratory and bulbar function in persons with amyotrophic lateral sclerosis (ALS). Twenty-five ALS patients participated in this delayed intervention open-label clinical trial. Following a lead-in period, patients completed a 5-week EMST protocol. Outcome measures included: maximum expiratory pressure (MEP); physiologic measures of swallow and cough; and penetration-aspiration scale (PAS) scores. Of participants who entered the active phase of the study (n = 15), EMST was well tolerated and led to significant increases in MEPs and maximum hyoid displacement during swallowing post-EMST (P < 0.05). No significant differences were observed for PAS scores or cough spirometry measures. EMST was feasible and well tolerated in this small cohort of ALS patients and led to improvements in expiratory force-generating pressures and swallow kinematics. Further investigation is warranted to confirm these preliminary findings. Muscle Nerve 54: 48-53, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  6. Diagnostic methods to assess inspiratory and expiratory muscle strength

    Directory of Open Access Journals (Sweden)

    Pedro Caruso

    2015-04-01

    Full Text Available Impairment of (inspiratory and expiratory respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation; and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength.

  7. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    Science.gov (United States)

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved

  8. Airway pressure release ventilation and biphasic positive airway pressure: a systematic review of definitional criteria.

    Science.gov (United States)

    Rose, Louise; Hawkins, Martyn

    2008-10-01

    The objective of this study was to identify the definitional criteria for the pressure-limited and time-cycled modes: airway pressure release ventilation (APRV) and biphasic positive airway pressure (BIPAP) available in the published literature. Systematic review. Medline, PubMed, Cochrane, and CINAHL databases (1982-2006) were searched using the following terms: APRV, BIPAP, Bilevel and lung protective strategy, individually and in combination. Two independent reviewers determined the paper eligibility and abstracted data from 50 studies and 18 discussion articles. Of the 50 studies, 39 (78%) described APRV, and 11 (22%) described BIPAP. Various study designs, populations, or outcome measures were investigated. Compared to BIPAP, APRV was described more frequently as extreme inverse inspiratory:expiratory ratio [18/39 (46%) vs. 0/11 (0%), P = 0.004] and used rarely as a noninverse ratio [2/39 (5%) vs. 3/11 (27%), P = 0.06]. One (9%) BIPAP and eight (21%) APRV studies used mild inverse ratio (>1:1 to branding may further add to confusion. Generic naming of modes and consistent definitional parameters may improve consistency of patient response for a given mode and assist with clinical implementation.

  9. Successful use of non-invasive positive pressure ventilation in a complicated flail chest

    International Nuclear Information System (INIS)

    Al-Ansari, Mariam A.

    2006-01-01

    The current advanced trauma life support manual states that patients with significant hypoxia (namely, SaO2<90% on room air) as a result of pulmonary contusion should be intubated and ventilated within the first hour of injury. Recently, several researchers have shown improved outcomes when patients with acute respiratory failure are managed with noninvasive positive pressure ventilation (NIPPV). Trauma patients may also benefit from this therapy. We report a case of 15-year-old boy who isolated flail chest and pulmonary contusion, who was intubated in the emergency room, and was managed successfully with the NIPPV in the intensive care unit (ICU) despite, having had aspiration pneumonia early in the course of her stay. After initial stabilization, he failed a spontaneous breathing trial. Due to absence of contraindications to the use of NIPPV, the patient was extubated on day 7 (from pressure ventilation of 15 cmH2O and positive end expiratory pressure of 8 cm H2O) to immediate NIPPV use. Three days later (after a total of 50 hours of NIPPV use in the ICU) the patient was successfully discharged home. (author)

  10. Protective intraoperative ventilation with higher versus lower levels of positive end-expiratory pressure in obese patients (PROBESE): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Bluth, T; Teichmann, R; Kiss, T; Bobek, I; Canet, J; Cinnella, G; De Baerdemaeker, L; Gregoretti, C; Hedenstierna, G; Hemmes, S N; Hiesmayr, M; Hollmann, M W; Jaber, S; Laffey, J G; Licker, M J; Markstaller, K; Matot, I; Müller, G; Mills, G H; Mulier, J P; Putensen, C; Rossaint, R; Schmitt, J; Senturk, M; Serpa Neto, A; Severgnini, P; Sprung, J; Vidal Melo, M F; Wrigge, H; Schultz, M J; Pelosi, P; Gama de Abreu, M

    2017-04-28

    Postoperative pulmonary complications (PPCs) increase the morbidity and mortality of surgery in obese patients. High levels of positive end-expiratory pressure (PEEP) with lung recruitment maneuvers may improve intraoperative respiratory function, but they can also compromise hemodynamics, and the effects on PPCs are uncertain. We hypothesized that intraoperative mechanical ventilation using high PEEP with periodic recruitment maneuvers, as compared with low PEEP without recruitment maneuvers, prevents PPCs in obese patients. The PRotective Ventilation with Higher versus Lower PEEP during General Anesthesia for Surgery in OBESE Patients (PROBESE) study is a multicenter, two-arm, international randomized controlled trial. In total, 2013 obese patients with body mass index ≥35 kg/m 2 scheduled for at least 2 h of surgery under general anesthesia and at intermediate to high risk for PPCs will be included. Patients are ventilated intraoperatively with a low tidal volume of 7 ml/kg (predicted body weight) and randomly assigned to PEEP of 12 cmH 2 O with lung recruitment maneuvers (high PEEP) or PEEP of 4 cmH 2 O without recruitment maneuvers (low PEEP). The occurrence of PPCs will be recorded as collapsed composite of single adverse pulmonary events and represents the primary endpoint. To our knowledge, the PROBESE trial is the first multicenter, international randomized controlled trial to compare the effects of two different levels of intraoperative PEEP during protective low tidal volume ventilation on PPCs in obese patients. The results of the PROBESE trial will support anesthesiologists in their decision to choose a certain PEEP level during general anesthesia for surgery in obese patients in an attempt to prevent PPCs. ClinicalTrials.gov identifier: NCT02148692. Registered on 23 May 2014; last updated 7 June 2016.

  11. Auto-trilevel versus bilevel positive airway pressure ventilation for hypercapnic overlap syndrome patients.

    Science.gov (United States)

    Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong

    2018-03-01

    Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency

  12. Role of bronchodilation and pattern of breathing in increasing tidal expiratory flow with progressive induced hypercapnia in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Finucane, Kevin E; Singh, Bhajan

    2018-01-01

    Hypercapnia (HC) in vitro relaxes airway smooth muscle; in vivo, it increases respiratory effort, tidal expiratory flows (V̇ exp ), and, by decreasing inspiratory duration (Ti), increases elastic recoil pressure (Pel) via lung viscoelasticity; however, its effect on airway resistance is uncertain. We examined the contributions of bronchodilation, Ti, and expiratory effort to increasing V̇ exp with progressive HC in 10 subjects with chronic obstructive pulmonary disease (COPD): mean forced expiratory volume in 1 s (FEV 1 ) 53% predicted. Lung volumes (Vl), V̇ exp , esophageal pressure (Pes), Ti, and end-tidal Pco 2 ([Formula: see text]) were measured during six tidal breaths followed by an inspiratory capacity (IC), breathing air, and at three levels of HC. V̇ exp and V̇ with submaximal forced vital capacities breathing air (V̇ sFVC ) were compared. Pulmonary resistance ( Rl) was measured from the Pes-V̇ relationship. V̇ exp and Pes at end-expiratory lung volume (EELV) + 0.3 tidal volume [V̇ (0.3Vt) and Pes (0.3Vt) , respectively], Ti, and Rl correlated with [Formula: see text] ( P pulmonary disease (COPD), progressive HC increases tidal expiratory flows by inducing bronchodilation and via an increased rate of inspiration and lung viscoelasticity, a probable increase in lung elastic recoil pressure, both changes increasing expiratory flows, promoting lung emptying and a stable end-expiratory volume. Bronchodilation with HC occurred despite optimal standard bronchodilator therapy, suggesting that in COPD further bronchodilation is possible.

  13. Validation of a protocol to evaluate maximal expiratory pressure using a pressure transducer and a signal conditioner

    Directory of Open Access Journals (Sweden)

    Viviane Soares

    2011-09-01

    Full Text Available The respiratory muscles can present fatigue and even chronic inability to generate force. So, reliable devices are necessary to their evaluation. The aim of this study is to evaluate the MEP (Maximal Expiratory Pressure values of individuals between 20 and 25 years old and to validate a protocol using a pressure transducer and a signal conditioner comparing it with the digital manometer. We evaluated the MEP of 10 participants. They remained seated and made six respiratory maneuvers from Total Lung Capacity (TLC to Residual Volume (RV. The results in the study showed no statistically significant differences when compared to values reported in the literature, and that the pressure transducer provides reliable values for MEP.Os músculos respiratórios podem apresentar fadiga e até mesmo a incapacidade crônica na geração de força, sendo necessários dispositivos confiáveis para sua avaliação. O objetivo deste estudo foi avaliar a pressão expiratória máxima (PeMáx de indivíduos entre 20 e 25 anos e validar um protocolo que utiliza um transdutor de pressão e um condicionador de sinais comparando-o com a manovacuometria. Foram avaliadas a PeMáx de 10 participantes. Estes permaneceram sentados e realizaram seis manobras respiratórias a partir da capacidade pulmonar total (CPT até o volume residual (VR. Os resultados do estudo não apresentaram diferenças estatisticamente significativas quando comparados com os valores de normalidade descritos na literatura e mostraram que o transdutor de pressão fornece valores confiáveis para Pe máx.

  14. Multi-detector CT evaluation in patients suspected of tracheobronchomalacia: Comparison of end-expiratory with dynamic expiratory volumetric acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, Gilbert R. [Department of Radiology (France)], E-mail: gferretti@chu-grenoble.fr; Jankowski, Adrien [Department of Radiology (France)], E-mail: ajankowski@chu-grenoble.fr; Perrin, Marie Amelie [Department of Radiology (France)], E-mail: maperrin@chu-grenoble.fr; Chouri, Nathalie [Department of Respiratory Diseases (France)], E-mail: nchouri@chu-grenoble.fr; Arnol, Nathalie [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: narnold@chu-grenoble.fr; Aubaud, Laurent [Department of Radiology (France)], E-mail: laubaud@chu-grenoble.fr; Pepin, Jean-Louis [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: jlpepin@chu-grenoble.fr

    2008-11-15

    Purpose: The aim of this study was to compare dynamic expiratory imaging and end-expiratory imaging using multi-detector CT (MDCT) of the central airways in patients suspected of tracheobronchomalacia (TBM). Methods: This study had local ethical committee approval. Seventy patients suspected of TBM were prospectively included. All patients underwent evaluation of central airways by three different low-dose MDCT acquisitions: end inspiration, end expiration, and dynamic expiration. Degree of airway collapse was measured by calculating the percentage change in the area and diameter of the airways between inspiratory and the two expiratory techniques at three levels of the trachea and in the sagittal diameter of the right and left main bronchi. Three threshold levels of percentage reduction in diameter or area (30%, 50%, and 70%) for defining TBM were evaluated. Results: In the entire population, the mean percentage of airway collapse was significantly greater with dynamic expiratory imaging than with the end-expiratory imaging at three different levels: lower thoracic trachea (26% vs. 16.6%, p < 0.009), right (25.2% vs. 14%, p < 0.01) and left main (24.7% vs. 13.3%, p < 0.01) bronchus. Whatever the threshold value for defining TBM, dynamic expiratory imaging always resulted in diagnosing TBM in more patients than end-expiratory imaging. Conclusions: Dynamic expiratory imaging shows a significantly greater degree and a significantly greater extent of airway collapse than standard end-expiratory imaging in patients suspected of TBM. Further evaluation of the clinical relevance of such findings is warranted.

  15. OPTIMUM LEVEL OF POSITIVE END-EXPIRATORY PRESSURE IN ACUTE RESPIRATORY DISTRESS SYNDROME CAUSED BY INFLUENZA A(H1NI)PDM09: BALANCE BETWEEN MAXIMAL END-EXPIRATORY VOLUME AND MINIMAL ALVEOLAR OVERDISTENSION.

    Science.gov (United States)

    Yaroshetskiym A I; Protsenko, D N; Boytsov, P V; Chentsov, V B; Nistratov, S L; Kudlyakov, O N; Solov'ev, V V; Banova, Zh I; Shkuratova, N V; Rezenov, N A; Gel'fand, B R

    2016-11-01

    to determine optimum level ofpositive end-expiratory pressure (PEEP) according to balance between maxi- mal end-expiratory lung volume (EEL V)(more than predicted) and minimal decrease in exhaled carbon dioxide volume (VCO) and then to develop the algorithm of gas exchange correction based on prognostic values of EEL K; alveolar recruitability, PA/FiO2, static compliance (C,,,) and VCO2. 27 mechanically ventilatedpatients with acute respiratory distress syndrome (ARDS) caused by influenza A (HINJ)pdm09 in Moscow Municipal Clinics ICU's from January to March 2016 were included in the trial. At the beginning of the study patients had the following characteristic: duration offlu symptoms 5 (3-10) days, p.0/FiO2 120 (70-50) mmHg. SOFA 7 (5-9), body mass index 30.1 (26.4-33.8) kg/m², static compliance of respiratory system 35 (30-40) ml/mbar: Under sedation and paralysis we measured EELV, C VCO and end-tidal carbon dioxide concentration (EtCO) (for CO₂ measurements we fixed short-term values after 2 min after PEEP level change) at PEEP 8, 11,13,15,18, 20 mbar consequently, and incase of good recruitability, at 22 and 24 mbar. After analyses of obtained data we determined PEEP value in which increase in EELV was maximal (more than predicted) and depression of VCO₂ was less than 20%, change in mean blood pressure and heart rate were both less than 20% (measured at PEEP 8 mbar). After that we set thus determined level of PEEP and didn't change it for 5 days. Comparision of predicted and measured EELV revealed two typical points of alveloar recruiment: the first at PEEP 11-15 mbar, the second at PEEP 20-22 mbar. EELV measured at PEEP 18 mbar appeared to be higher than predicted at PEEP 8 mbar by 400 ml (approx.), which was the sign of alveolar recruitment-1536 (1020-1845) ml vs 1955 (1360-2320) ml, p=0,001, Friedman test). we didn't found significant changes of VCO₂ when increased PEEP in the range from 8 to 15 mbar (p>0.05, Friedman test). PEEP increase from 15 to

  16. Parameters affecting the tidal volume during expiratory abdominal compression in patients with prolonged tracheostomy mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] The aim of this study was to clarify physical parameters affecting the tidal volume during expiratory abdominal compression in patients with prolonged tracheostomy mechanical ventilation. [Methods] Eighteen patients with prolonged mechanical ventilation were included in this study. Expiratory abdominal compression was performed on patients lying in a supine position. The abdomen above the navel was vertically compressed in synchronization with expiration and released with inspiration. We measured the tidal volume during expiratory abdominal compression. [Results] The mean tidal volume during expiratory abdominal compression was higher than that at rest (430.6 ± 127.1 mL vs. 344.0 ± 94.3 mL). The tidal volume during expiratory abdominal compression was correlated with weight, days of ventilator support, dynamic compliance and abdominal expansion. Stepwise multiple regression analysis revealed that weight (β = 0.499), dynamic compliance (β = 0.387), and abdominal expansion (β = 0.365) were factors contributing to the tidal volume during expiratory abdominal compression. [Conclusion] Expiratory abdominal compression increased the tidal volume in patients with prolonged tracheostomy mechanical ventilation. The tidal volume during expiratory abdominal compression was influenced by each of the pulmonary conditions and the physical characteristics.

  17. Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

    Science.gov (United States)

    Tonnelier, Alexandre; Lellouche, François; Bouchard, Pierre Alexandre; L'Her, Erwan

    2013-08-01

    Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. To evaluate the influence of nebulization and active humidification on the resistance of expiratory filters. A respiratory system analog was constructed using a test lung, an ICU ventilator, heated humidifiers, and a piezoelectric nebulizer. Humidifiers were connected to different types of circuits (unheated, mono-heated, new-generation and old-generation bi-heated). Five filter types were evaluated: electrostatic, heat-and-moisture exchanger, standard, specific, and internal heated high-efficiency particulate air [HEPA] filter. Baseline characteristics were obtained from each dry filter. Differential pressure measurements were carried out after 24 hours of continuous in vitro use for each condition, and after 24 hours of use with an old-generation bi-heated circuit without nebulization. While using unheated circuits, measurements had to be interrupted before 24 hours for all the filtering devices except the internal heated HEPA filter. The heat-and-moisture exchangers occluded before 24 hours with the unheated and mono-heated circuits. The circuit type, nebulization practice, and duration of use did not influence the internal heated HEPA filter resistance. Expiratory limb filtration is likely to induce several major adverse events. Expiratory filter resistance increase is due mainly to the humidification circuit type, rather than to nebulization. If filtration is mandatory while using an unheated circuit, a dedicated filter should be used for ≤ 24 hours, or a heated HEPA for a longer duration.

  18. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation

    OpenAIRE

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-01-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects ...

  19. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    Science.gov (United States)

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  20. Expiratory muscle control during vomiting - Role of brain stem expiratory neurons

    Science.gov (United States)

    Miller, A. D.; Tan, L. K.

    1987-01-01

    The neural mechanisms controlling the muscles involved during vomiting were examined using decerebrated cats. In one experiment, the activity of the ventral respiratory group (VRG) expiratory (E) neurons was recorded during induced 'fictive vomiting' (i.e., a series of bursts of coactivation of abdominal and phrenic nerves that would be expected to produce expulsion in unparalyzed animals) and vomiting. In a second, abdominal muscle electromyographic and nerve activity were compared before and after sectioning the axons of descending VRG E neurons as they cross the midline between C1 and the obex (the procedure that is known to abolish expiratory modulation of internal intercostal muscle activity). The results of the study indicate that the abdominal muscles are controlled differently during respiration and vomiting.

  1. High positive end-expiratory pressure levels promote bacterial translocation in experimental pneumonia

    NARCIS (Netherlands)

    Lachmann, Robert A.; van Kaam, Anton H.; Haitsma, Jack J.; Lachmann, Burkhard

    2007-01-01

    A previous study in piglets with experimental pneumonia showed that reducing atelectasis by means of open lung ventilation attenuated bacterial translocation compared to conventional ventilation settings. This study examined the effect of open lung ventilation with higher than necessary positive

  2. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  3. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    Science.gov (United States)

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  4. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  5. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... ENT Doctor Near You Continuous Positive Airway Pressure (CPAP) Continuous Positive Airway Pressure (CPAP) Patient Health Information ... relations staff at newsroom@entnet.org . What Is CPAP? The most common and effective nonsurgical treatment for ...

  6. Efeitos da aplicação da EPAP (Expiratory Positive Airway Pressure sobre a tolerância ao esforço em pacientes portadores de insuficiência cardíaca

    Directory of Open Access Journals (Sweden)

    Claudia Thofehrn

    2013-04-01

    Full Text Available INTRODUÇÃO: Novas abordagens terapêuticas que objetivam melhorar a sensação de dispneia e fadiga em pacientes com insuficiência cardíaca, como a aplicação de pressão positiva expiratória nas vias aéreas (EPAP, podem ser aplicadas na tentativa de melhorar a capacidade funcional e a qualidade de vida. OBJETIVO: Avaliar os efeitos da utilização da EPAP ( Expiratory Positive Airway Pressure durante o esforço em indivíduos portadores de IC classe funcional II e III (NYHA. MÉTODOS: Dos 390 pacientes, foram selecionados 28 com FEVE < 40%. O Teste de Caminhada de seis minutos (TC6' foi realizado três vezes: o primeiro para a familiarização, um com a máscara e o outro sem a máscara de EPAP, sendo válido os dois últimos. A comparação entre os dados obtidos foi realizada por meio de teste t de Student pareado ou teste de Wilcoxon, conforme a normalidade dos dados. RESULTADOS: a percepção de esforço foi maior após a caminhada com a utilização da máscara quando comparado na ausência da máscara. Houve elevação significativa na saturação de oxigênio quando os pacientes estavam usando a máscara de EPAP. CONCLUSÃO: O uso da máscara de EPAP aumenta a percepção de esforço e o trabalho ventilatório, porém, não aumentou a distância percorrida no TC6, sendo sua aplicabilidade questionável em programas de reabilitação cardiovascular.

  7. Effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by parkinson's disease.

    Science.gov (United States)

    Byeon, Haewon

    2016-06-01

    [Purpose] This study aimed to investigate the effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by Parkinson's disease. [Subjects and Methods] The subjects of this study were 18 patients who received simultaneous application of postural techniques and expiratory muscle strength training and 15 patients who received expiratory muscle strength training only. Postural techniques were conducted in the order of chin tucking, head rotation, head tilting, bending head back, and lying down, while expiratory muscle strength training was conducted at a resistance level of about 70% of the maximal expiratory pressure. Swallowing recovery was assessed by using the Functional Dysphagia Scale based on videofluoroscopic studies. [Results] The mean value obtained in the videofluoroscopic studies for both groups decreased after the treatment. In the postural techniques plus expiratory muscle strength training group, the decrease was significantly greater than that in the expiratory muscle strength training-only group. [Conclusion] The results imply that simultaneous performance of postural techniques and expiratory muscle strength training is more effective than expiratory muscle strength training alone when applied in the swallowing rehabilitation for patients with dysphagia caused by Parkinson's disease.

  8. Positive airway pressure adherence and subthreshold adherence in posttraumatic stress disorder patients with comorbid sleep apnea

    Directory of Open Access Journals (Sweden)

    Krakow BJ

    2017-11-01

    Full Text Available Barry J Krakow,1–3 Jessica J Obando,2 Victor A Ulibarri,1,2 Natalia D McIver1,2 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, USA Study objectives: Patients with comorbid posttraumatic stress disorder (PTSD and obstructive sleep apnea (OSA manifest low adherence to continuous positive airway pressure (CPAP due to fixed, pressure-induced expiratory pressure intolerance (EPI, a subjective symptom and objective sign aggravated by anxiety sensitivity and somatosensory amplification. As advanced PAP therapy modes (ie, auto-bilevel PAP [ABPAP] or adaptive servo-ventilation [ASV] may address these side effects, we hypothesized such treatment would be associated with decreased expiratory intolerance and increased adherence in posttraumatic stress patients with co-occurring OSA.Methods: We reviewed charts of 147 consecutive adult patients with moderately severe posttraumatic stress symptoms and objectively diagnosed OSA. All patients failed or rejected CPAP and were manually titrated on auto-adjusting, dual-pressure ABPAP or ASV modes in the sleep laboratory, a technique to eliminate flow limitation breathing events while resolving EPI. Patients were then prescribed either mode of therapy. Follow-up encounters assessed patient use, and objective data downloads (ODDs measured adherence.Results: Of 147 charts reviewed, 130 patients were deemed current PAP users, and 102 provided ODDs: 64 used ASV and 38 used ABPAP. ODDs yielded three groups: 59 adherent per insurance conventions, 19 subthreshold compliant partial users, and 24 noncompliant. Compliance based on available downloads was 58%, notably higher than recently reported rates in PTSD patients with OSA. Among the 19 partial users, 17 patients were minutes of PAP use or small percentages of nights removed from meeting insurance compliance criteria for PAP devices.Conclusion: Research is warranted on advanced PAP modes in

  9. Intrathoracic pressure regulation during cardiopulmonary resuscitation: a feasibility case-series.

    Science.gov (United States)

    Segal, Nicolas; Parquette, Brent; Ziehr, Jonathon; Yannopoulos, Demetris; Lindstrom, David

    2013-04-01

    Intrathoracic pressure regulation (IPR) is a novel, noninvasive therapy intended to increase cardiac output and blood pressure in hypotensive states by generating a negative end expiratory pressure of -12 cm H2O between positive pressure ventilations. In this first feasibility case-series, we tested the hypothesis that IPR improves End tidal (ET) CO2 during cardiopulmonary resuscitation (CPR). ETCO2 was used as a surrogate measure for circulation. All patients were treated initially with manual CPR and an impedance threshold device (ITD). When IPR-trained medics arrived on scene the ITD was removed and an IPR device (CirQLATOR™) was attached to the patient's advanced airway (intervention group). The IPR device lowered airway pressures to -9 mmHg after each positive pressure ventilation for the duration of the expiratory phase. ETCO2, was measured using a capnometer incorporated into the defibrillator system (LifePak™). Values are expressed as mean ± SEM. Results were compared using paired and unpaired Student's t test. p values of <0.05 were considered statistically significant. ETCO2 values in 11 patients in the case series were compared pre and during IPR therapy and also compared to 74 patients in the control group not treated with the new IPR device. ETCO2 values increased from an average of 21 ± 1 mmHg immediately before IPR application to an average value of 32 ± 5 mmHg and to a maximum value of 45 ± 5mmHg during IPR treatment (p<0.001). In the control group ETCO2 values did not change significantly. Return of spontaneous circulation (ROSC) rates were 46% (34/74) with standard CPR and ITD versus 73% (8/11) with standard CPR and the IPR device (p<0.001). ETCO2 levels and ROSC rates were significantly higher in the study intervention group. These findings demonstrate that during CPR circulation may be significantly augmented by generation of a negative end expiratory pressure between each breath. Copyright © 2012 Elsevier Ireland Ltd. All rights

  10. Utilization of the lower inflection point of the pressure-volume curve results in protective conventional ventilation comparable to high frequency oscillatory ventilation in an animal model of acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Felipe S. Rossi

    2008-01-01

    Full Text Available INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH2O. Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.

  11. Effects of vertical positioning on gas exchange and lung volumes in acute respiratory distress syndrome.

    Science.gov (United States)

    Richard, Jean-Christophe M; Maggiore, Salvatore Maurizio; Mancebo, Jordi; Lemaire, François; Jonson, Bjorn; Brochard, Laurent

    2006-10-01

    Supine position may contribute to the loss of aerated lung volume in patients with acute respiratory distress syndrome (ARDS). We hypothesized that verticalization increases lung volume and improves gas exchange by reducing the pressure surrounding lung bases. Prospective observational physiological study in a medical ICU. In 16 patients with ARDS we measured arterial blood gases, pressure-volume curves of the respiratory system recorded from positive-end expiratory pressure (PEEP), and changes in lung volume in supine and vertical positions (trunk elevated at 45 degrees and legs down at 45 degrees ). Vertical positioning increased PaO(2) significantly from 94+/-33 to 142+/-49 mmHg, with an increase higher than 40% in 11 responders. The volume at 20 cmH(2)O measured on the PV curve from PEEP increased using the vertical position only in responders (233+/-146 vs. -8+/-9 1ml in nonresponders); this change was correlated to oxygenation change (rho=0.55). End-expiratory lung volume variation from supine to vertical and 1 h later back to supine, measured in 12 patients showed a significant increase during the 1-h upright period in responders (n=7) but not in nonresponders (n=5; 215+/-220 vs. 10+/-22 ml), suggesting a time-dependent recruitment. Vertical positioning is a simple technique that may improve oxygenation and lung recruitment in ARDS patients.

  12. Thoracoabdominal mobility evaluation by photogrammetry in newborns after expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Júlia Isabel de Araújo Guerra

    Full Text Available Abstract Introduction: Expiratory flow increase is a maneuver of respiratory physical therapy that promotes flow direction to the upper airways however, when applied in newborns, it may result in changes of thoracoabdominal mobility. Objective: To evaluate the thoracoabdominal mobility by photogrammetry in newborns after expiratory flow increase technique. Methods: Experimental blind study performed with newborns in supine position on a support table with upper limbs flexed, abducted and externally rotated and hip flexed at 110°. Adhesive markers were allocated for geometric delimitation of the thoracoabdominal compartment and expiratory flow increase technique was performed for 5 minutes with the therapist’s hands on the thorax and abdomen. Newborns were filmed before and after the maneuver and the frames were analyzed in AutoCAD® software by a blinded investigator at the time of the procedure. The largest and the smallest thoracoabdominal area were expressed in cm2 and the mean values were compared between two moments (pre and post maneuver by paired t test. Results: Twenty newborns with a mean age of 39 weeks were included. Before the maneuver, thoracoabdominal area was 56.1 cm2 during expiration and 59.7 cm2 during inspiration, and after the maneuver the value was 56.2 cm2 during expiration and 59.8 cm2 during inspiration, with no statistical difference between before and after (p = 0.97, p = 0.92, respectively. Conclusion: Results demonstrate that expiratory flow increase technique does not seem to change thoracoabdominal mobility of healthy newborns.

  13. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  14. Expiratory timing in obstructive sleep apnoeas.

    Science.gov (United States)

    Cibella, F; Marrone, O; Sanci, S; Bellia, V; Bonsignore, G

    1990-03-01

    Diaphragmatic electromyogram was recorded during NREM sleep in 4 patients affected by obstructive sleep apnoea (OSA) syndrome in order to evaluate the behaviour of expiratory time (TE) in the course of the obstructive apnoea-ventilation cycle. The two components of TE, i.e. time of post-inspiratory inspiratory activity (TPIIA) and time of expiratory phase 2 (TE2) were separately analysed. TPIIA showed a short duration, with only minor variations, within the apnoea, while its duration was more variable and longer in the interapnoeic periods: the longest TPIIA values were associated with the highest inspiratory volumes in the same breaths. This behaviour seemed regulated according to the need of a more or less effective expiratory flow braking, probably as a result of pulmonary stretch receptors discharge. Conversely TE2 showed a continuous gradual modulation, progressively increasing in the pre-apnoeic period, decreasing during the apnoea and increasing in the post-apnoeic period: these TE2 variations seemed related to oscillations in chemical drive. These data show that TE in the obstructive apnoea-ventilation cycle results from a different modulation in its two components and suggest that both mechanical and chemical influences play a role in its overall duration.

  15. Mechanical breath profile of airway pressure release ventilation: the effect on alveolar recruitment and microstrain in acute lung injury.

    Science.gov (United States)

    Kollisch-Singule, Michaela; Emr, Bryanna; Smith, Bradford; Roy, Shreyas; Jain, Sumeet; Satalin, Joshua; Snyder, Kathy; Andrews, Penny; Habashi, Nader; Bates, Jason; Marx, William; Nieman, Gary; Gatto, Louis A

    2014-11-01

    Improper mechanical ventilation settings can exacerbate acute lung injury by causing a secondary ventilator-induced lung injury. It is therefore important to establish the mechanism by which the ventilator induces lung injury to develop protective ventilation strategies. It has been postulated that the mechanism of ventilator-induced lung injury is the result of heterogeneous, elevated strain on the pulmonary parenchyma. Acute lung injury has been associated with increases in whole-lung macrostrain, which is correlated with increased pathology. However, the effect of mechanical ventilation on alveolar microstrain remains unknown. To examine whether the mechanical breath profile of airway pressure release ventilation (APRV), consisting of a prolonged pressure-time profile and brief expiratory release phase, reduces microstrain. In a randomized, nonblinded laboratory animal study, rats were randomized into a controlled mandatory ventilation group (n = 3) and an APRV group (n = 3). Lung injury was induced by polysorbate lavage. A thoracotomy was performed and an in vivo microscope was placed on the lungs to measure alveolar mechanics. In the controlled mandatory ventilation group, multiple levels of positive end-expiratory pressure (PEEP; 5, 10, 16, 20, and 24 cm H2O) were tested. In the APRV group, decreasing durations of expiratory release (time at low pressure [T(low)]) were tested. The T(low) was set to achieve ratios of termination of peak expiratory flow rate (T-PEFR) to peak expiratory flow rate (PEFR) of 10%, 25%, 50%, and 75% (the smaller this ratio is [ie, 10%], the more time the lung is exposed to low pressure during the release phase, which decreases end-expiratory lung volume and potentiates derecruitment). Alveolar perimeters were measured at peak inspiration and end expiration using digital image analysis, and strain was calculated by normalizing the change in alveolar perimeter length to the original length. Macrostrain was measured by volume

  16. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  17. The effect of positive expiratory pressure (PEP) therapy on symptoms, quality of life and incidence of re-exacerbation in patients with acute exacerbations of chronic obstructive pulmonary disease: a multicentre, randomised controlled trial.

    Science.gov (United States)

    Osadnik, Christian R; McDonald, Christine F; Miller, Belinda R; Hill, Catherine J; Tarrant, Ben; Steward, Ranjana; Chao, Caroline; Stodden, Nicole; Oliveira, Cristino C; Gagliardi, Nadia; Holland, Anne E

    2014-02-01

    Positive expiratory pressure (PEP) is a technique used to enhance sputum clearance during acute exacerbations of chronic obstructive pulmonary disease (AECOPD). The impact of PEP therapy during acute exacerbations on clinically important outcomes is not clear. This study sought to determine the effect of PEP therapy on symptoms, quality of life and future exacerbations in patients with AECOPD. 90 inpatients (58 men; mean age 68.6 years, FEV(1) 40.8% predicted) with AECOPD and sputum expectoration were randomised to receive usual care (including physical exercise)±PEP therapy. The Breathlessness, Cough and Sputum Scale (BCSS), St George's Respiratory Questionnaire (SGRQ) and BODE index (Body mass index, airflow Obstruction, Dyspnoea, Exercise tolerance) were measured at discharge, 8 weeks and 6 months following discharge, and analysed via linear mixed models. Exacerbations and hospitalisations were recorded using home diaries. There were no significant between-group differences over time for BCSS score [mean (SE) at discharge 5.2 (0.4) vs 5.0 (0.4) for PEP and control group, respectively; p=0.978] or SGRQ total score [41.6 (2.6) vs 40.8 (2.8) at 8 weeks, p=0.872]. Dyspnoea improved more rapidly in the PEP group over the first 8 weeks (p=0.006), however these benefits were not observed at 6 months. Exacerbations (p=0.986) and hospitalisations (p=0.359) did not differ between groups. We found no evidence that PEP therapy during AECOPD improves important short-term or long-term outcomes. There does not appear to be a routine role for PEP therapy in the management of such individuals.

  18. Peak Expiratory Flow Rate In Cigarette Smokers | Ukoli | Highland ...

    African Journals Online (AJOL)

    Objective: To compare lung function between smokers and non-smokers using Peak Expiratory Flow Rate (PEFR). Methods: This study examines the peak expiratory flow rate (PEFR) of three hundred and forty cigarette smokers, age and sex-matched with PEFR of equal number of non-smokers. Results: The mean PEFR of ...

  19. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation.

    Science.gov (United States)

    Shojaee, Majid; Sabzghabaei, Anita; Alimohammadi, Hossein; Derakhshanfar, Hojjat; Amini, Afshin; Esmailzadeh, Bahareh

    2017-01-01

    Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH 2 O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male). The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH 2 O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH 2 O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH 2 O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039). The relationship between CVP and 5 cmH 2 O (p = 0.279), and 10 cmH 2 O (p = 0.292) PEEP changes were not dependent on the baseline level of CVP. The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH 2 O increase in PEEP will be associated with about 2.5 cmH 2 O raise in CVP. When applying a 5 cmH 2 O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH 2 O (2.5 vs. 1.6). It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  20. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    Majid Shojaee

    2016-12-01

    Full Text Available Introduction: Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. Methods: In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH2O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. Results: 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male. The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH2O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH2O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH2O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039. The relationship between CVP and 5 cmH2O (p = 0.279, and 10 cmH2O (p = 0.292 PEEP changes were not dependent on the baseline level of CVP. Conclusion: The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH2O increase in PEEP will be associated with about 2.5 cmH2O raise in CVP. When applying a 5 cmH2O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH2O (2.5 vs. 1.6. It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  1. Superoxide dismutase levels and peak expiratory flow in asthmatic children

    Directory of Open Access Journals (Sweden)

    Arie Kurniasih

    2016-11-01

    Full Text Available Background Asthma is a chronic inflammatory process which involve variety of cells such as inflammatory mediators, reactive oxygen species (ROS, and cytokines. The inflammatory process would be exacerbated in the presence of oxidative stress. Superoxide dismutase (SOD is the first important enzyme to protect the respiratory tract against oxidative stress. The decreased of SOD has a correlation with increased of airway obstruction and bronchospasm. Objective To assess for a correlation between superoxide dismutase (SOD levels and peak expiratory flow, as well as to determine the impact of SOD levels for predicting asthma attacks. Methods We conducted a prospective cohort study at Dr. Sardjito Hospital, Yogyakarta, between February and April 2011 involving asthmatic children aged 5-18 years. Subjects’ serum SOD levels and peak expiratory flow were measured at the same time point. We then performed a prospective study following up on the same subjects to find out if they had a recurrent asthma attack within one month of the tests. We also reassessed their peak expiratory flow one month after blood specimens were obtained. Results Thirty-nine patients were enrolled in this study. There was no significant correlation between SOD level and peak expiratory flow [r=0.289; 95%CI -0.025 to 0.47; P=0.074]. However, older age was significantly associated with higher peak expiratory flow (=0.5; 95%CI 3.10 to 11.57; P=0.01. Lower levels of SOD increased the risk of asthma attacks in a month following the initial measurements (RR=5.5; 95%CI 1.6 to 18.9; P=0.009. Conclusion Superoxide dismutase (SOD level is not significantly associated with peak expiratory flow. However, we find a relationship between older age and higher peak expiratory flow and a relationship between lower SOD levels and risk of asthma attacks within one month following the tests.

  2. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  3. Analysis of the static pressure volume curve of the lung in experimentally induced pulmonary damage by CT-densitometry

    International Nuclear Information System (INIS)

    David, M.; Karmrodt, J.; Herwelling, A.; Bletz, C.; David, S.; Heussel, C.P.; Markstaller, K.

    2005-01-01

    Purpose: To study quantitative changes of lung density distributions when recording in- and expiratory static pressure-volume curves by single slice computed tomography (CT). Materials and Methods: Static in- and expiratory pressure volume curves (0 to 1000 ml, increments of 100 ml) were obtained in random order in 10 pigs after induction of lung damage by saline lavage. Simultaneously, CT acquisitions (slice thickness 1 mm, temporal increment 2 s) were performed in a single slice (3 cm below the carina). In each CT image lung segmentation and planimetry of defined density ranges were achieved. The lung density ranges were defined as: hyperinflated (-1024 to -910 HU), normal aerated (-910 to -600 HU), poorly aerated (-600 to -300 HU), and non aerated (-300 to 200 HU) lung. Fractional areas of defined density ranges in percentage of total lung area were compared to recorded volume increments and airway pressures (atmospheric pressure, lower inflection point (LIP), LIP*0.5, LIP*1.5, peak airway pressure) of in- and expiratory pressure-volume curves. Results: Quantitative analysis of defined density ranges showed no differences between in- and expiratory pressure-volume curves. The amount of poorly aerated lung decreased and normal aerated lung increased constantly when airway pressure and volume were increased during inspiratory pressure-volume curves and vice versa during expiratory pressure-volume loops. Conclusion: Recruitment and derecruitment of lung atelectasis during registration of static in- and expiratory pressure-volume loops occurred constantly, but not in a stepwise manner. CT was shown to be an appropriate method to analyse these recruitment process. (orig.)

  4. Inspiratory and expiratory HRCT findings in healthy smokers' lung

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Kwak, Byung Kook; Choi, Chi Hoon; Yang, Keun Mung; Lee, Chang Joon; Joo, Dong Il; Kim, Yang Soo

    1998-01-01

    The purpose of this study is to evaluate the lung changes in healthy smokers, as seen on inspiratory and expiratory high-resolution computed tomography (HRCT). Twenty-seven healthy smokers (light smokers, below 20 pack-years, n=16; heavy smokers, above 20 pack-years, n=11) and 25 nonsmokers underwent inspiratory and expiratory HRCT. All healthy smokers had normal pulmonary function and chest radiography. Parenchymal and subpleural micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, bronchial wall thickening, bronchiectasis and septal line were evaluated on inspiratory scan and by air-trapping on expiratory scan. According to the findings of HRCT, heavy smokers and higher frequency of parenchymal micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, and air-trapping than nonsmokers and light smokers. (author). 13 refs., 1 tab., 4 figs

  5. The effects of intraoperative lung protective ventilation with positive end-expiratory pressure on blood loss during hepatic resection surgery: A secondary analysis of data from a published randomised control trial (IMPROVE).

    Science.gov (United States)

    Neuschwander, Arthur; Futier, Emmanuel; Jaber, Samir; Pereira, Bruno; Eurin, Mathilde; Marret, Emmanuel; Szymkewicz, Olga; Beaussier, Marc; Paugam-Burtz, Catherine

    2016-04-01

    During high-risk abdominal surgery the use of a multi-faceted lung protective ventilation strategy composed of low tidal volumes, positive end-expiratory pressure (PEEP) and recruitment manoeuvres, has been shown to improve clinical outcomes. It has been speculated, however, that mechanical ventilation using PEEP might increase intraoperative bleeding during liver resection. To study the impact of mechanical ventilation with PEEP on bleeding during hepatectomy. Post-hoc analysis of a randomised controlled trial. Seven French university teaching hospitals from January 2011 to August 2012. Patients scheduled for liver resection surgery. In the Intraoperative Protective Ventilation trial, patients scheduled for major abdominal surgery were randomly assigned to mechanical ventilation using low tidal volume, PEEP between 6 and 8  cmH2O and recruitment manoeuvres (lung protective ventilation strategy) or higher tidal volume, zero PEEP and no recruitment manoeuvres (non-protective ventilation strategy). The primary endpoint was intraoperative blood loss volume. A total of 79 (19.8%) patients underwent liver resections (41 in the lung protective and 38 in the non-protective group). The median (interquartile range) amount of intraoperative blood loss was 500 (200 to 800)  ml and 275 (125 to 800)  ml in the non-protective and lung protective ventilation groups, respectively (P = 0.47). Fourteen (35.0%) and eight (21.5%) patients were transfused in the non-protective and lung protective groups, respectively (P = 0.17), without a statistically significant difference in the median (interquartile range) number of red blood cells units transfused [2.5 (2 to 4) units and 3 (2 to 6) units in the two groups, respectively; P = 0.54]. During hepatic surgery, mechanical ventilation using PEEP within a multi-faceted lung protective strategy was not associated with increased bleeding compared with non-protective ventilation using zero PEEP. The current study was not

  6. Use of tidal breathing curves for evaluating expiratory airway obstruction in infants.

    Science.gov (United States)

    Hevroni, Avigdor; Goldman, Aliza; Blank-Brachfeld, Miriam; Abu Ahmad, Wiessam; Ben-Dov, Lior; Springer, Chaim

    2018-01-15

    To evaluate tidal breathing (TB) flow-volume and flow-time curves for identification of expiratory airway obstruction in infants. Pulmonary function tests were analyzed retrospectively in 156 infants aged 3-24 months with persistent or recurrent respiratory complaints. Parameters derived from TB curves were compared to maximal expiratory flow at functional residual capacity ([Formula: see text]maxFRC) measured by rapid thoracoabdominal compression technique. Analyzed parameters were: inspiratory time (t I ), expiratory time (t E ), tidal volume, peak tidal expiratory flow (PTEF), time to peak tidal expiratory flow (t PTEF ), expiratory flow when 50% and 25% of tidal volume remains in the lungs (FEF 50 , FEF 25 , respectively), and the ratios t PTEF /t E , t I /t E , FEF 50 /PTEF, and FEF 25 /PTEF. Statistical comparisons between flow indices and TB parameters were performed using mean squared error and Pearson's sample correlation coefficient. The study population was also divided into two groups based on severity of expiratory obstruction (above or below z-score for [Formula: see text]maxFRC of -2) to generate receiver operating characteristic (ROC) curves and calculate discriminatory values between the groups. TB parameters that were best correlated to [Formula: see text]maxFRC were: t PTEF /t E , FEF 50 /PTEF, and FEF 25 /PTEF, with r = 0.61, 0.67, 0.65, respectively (p < 0.0001 for all). ROC curves for FEF 50 /PTEF, FEF 25 /PTEF and t PTEF /t E showed areas under the curve of 0.813, 0.797, and 0.796, respectively. Cutoff value z-scores of -0.35, -0.34, and -0.43 for these three parameters, respectively, showed an 86% negative predictive value for severe airway obstructions. TB curves can assist in ruling out severe expiratory airway obstruction in infants.

  7. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water

    Directory of Open Access Journals (Sweden)

    Danize Aparecida Rizzetti

    Full Text Available ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP; CPAP5 (CPAP at 5 cmH2O; and CPAP10 (CPAP at 10 cmH2O. We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR, and FEF25-75% at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  8. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water.

    Science.gov (United States)

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  9. Gadolinium prevents high airway pressure-induced permeability increases in isolated rat lungs.

    Science.gov (United States)

    Parker, J C; Ivey, C L; Tucker, J A

    1998-04-01

    To determine the initial signaling event in the vascular permeability increase after high airway pressure injury, we compared groups of lungs ventilated at different peak inflation pressures (PIPs) with (gadolinium group) and without (control group) infusion of 20 microM gadolinium chloride, an inhibitor of endothelial stretch-activated cation channels. Microvascular permeability was assessed by using the capillary filtration coefficient (Kfc), a measure of capillary hydraulic conductivity. Kfc was measured after ventilation for 30-min periods with 7, 20, and 30 cmH2O PIP with 3 cmH2O positive end-expiratory pressure and with 35 cmH2O PIP with 8 cmH2O positive end-expiratory pressure. In control lungs, Kfc increased significantly to 1.8 and 3.7 times baseline after 30 and 35 cmH2O PIP, respectively. In the gadolinium group, Kfc was unchanged from baseline (0.060 +/- 0.010 ml . min-1 . cmH2O-1 . 100 g-1) after any PIP ventilation period. Pulmonary vascular resistance increased significantly from baseline in both groups before the last Kfc measurement but was not different between groups. These results suggest that microvascular permeability is actively modulated by a cellular response to mechanical injury and that stretch-activated cation channels may initiate this response through increases in intracellular calcium concentration.

  10. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  11. Hearing Impairment and High Blood Pressure among Bus Drivers in Puducherry.

    Science.gov (United States)

    Balaji, Rajeshwar; Rajasegaran, Rajalakshmi; John, Nitin Ashok; Venkatappa, Umadevi Sajja

    2016-02-01

    Noise Induced Hearing Loss (NIHL), a major heath concern due to constant exposure to loud noise is on the rising trend in today's world. The bus drivers are more vulnerable to the auditory and non-auditory ill effects of noise pollution. The aim of this study was to assess and compare the hearing level, blood pressure and peak expiratory flow rate of bus drivers and individuals employed in office jobs. Fifty male bus drivers aged 30-50 years and fifty males of the same group employed in office jobs were recruited as the test and control groups respectively. The hearing level of the individuals in both the groups was assessed using the Hearing Deterioration Index (HDI). The lung function and cardiovascular status of the study participants were assessed by measuring their Peak Expiratory Flow Rate (PEFR) and Blood Pressure (BP) respectively. The mean HDI, PEFR and BP values of both the groups were compared using the unpaired t-test and the extent of correlation between HDI, service years, exposure level, systolic blood pressure (SBP) and diastolic blood pressure (DBP) was determined using Pearson correlation coefficient test. HDI, SBP and DBP were significantly higher among the bus drivers when compared to the controls. However, there was no significant difference in the PEFR values between the test and the control groups. There was a highly significant positive correlation between HDI and service years and exposure level. Similarly, there was a significant positive correlation between exposure level and systolic and diastolic blood pressure. Prolonged exposure to high intensity of sound results in deterioration of hearing capacity and increase in blood pressure among the bus drivers.

  12. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.

    Science.gov (United States)

    Chen, Yuqing; Cheng, Kewen; Zhou, Xin

    2015-01-26

    Pressure support ventilation from a bilevel device is a standard technique for non-invasive home ventilation. A bench study was designed to compare the performance and patient-ventilator synchronization of 7 bilevel ventilators, in the presence of system leaks. Ventilators were connected to a Hans Rudolph Series 1101 lung simulator (compliance, 50 mL/cmH2O; expiratory resistance, 20 cmH2O/L/s; respiratory rate, 15 breaths/min; inspiratory time, 1.0 s). All ventilators were set at 15 cmH2O pressure support and 5 cmH2O positive end-expiratory pressure. Tests were conducted at 2 system leaks (12-15 and 25-28 L/min). The performance characteristics and patient-ventilator asynchrony were assessed, including flow, airway pressure, time, and workload. The Breas Vivo30 could not synchronize with the simulator (frequent auto-triggering) at a leak of 25-28 L/min, but provided stable assisted ventilation when the leak was 12-15 L/min. Missed efforts and back-up ventilation occurred for the Weinmann VENTImotion and Airox Smartair Plus, requiring adjustment of trigger effort. All ventilators had a short trigger delay time (ventilators, possibly due to software algorithm differences. Adjusting the cycling criteria settings can alter the shape of the inspiratory phase and peak expiratory flow, and improve patient-ventilator synchrony.

  13. [Effectiveness of nasal positive pressure ventilation in the management of acute refractory left ventricular insufficiency].

    Science.gov (United States)

    Chesi, G; Pinelli, G; Galimberti, D; Navazio, A; Montanari, P

    1994-04-01

    Ehen refractory to optimal medical treatment cardiogenic pulmonary edema requires mechanical ventilation as a last therapeutic resource. In recent years an increasing number of authors reported their experience in the management of acute or subacute respiratory failure with non-invasive mechanical ventilation by nasal mask. Encouraged by the first promising results reported in literature we experimented this new therapeutic tool in a first group of seven elderly patients (mean age: 76.57--range: 65-89); they all had been admitted for severe cardiogenic pulmonary edema unresponsive to maximal doses of the conventional drugs available for treating acute decompensated heart failure. The enrolled patients were treated with intermittent ventilation administered by nasal mask at selected values of inspiratory positive airway pressure (IPAP) that were comprised between 10 and 20 cm H2O. At the same time an expiratory positive airway pressure (EPAP) at values comprised between 3 and 8 cm H2O was applied. Ventilation was continued for variable periods of 3-24 hours until acceptable values of PaO2 and PaCO2 were obtained. The ventilation modality was spontaneous, spontaneous-time or timed depending on the patients' level of consciousness at starting time. A good short-term outcome was achieved in all the patients regardless of the ventilation modality applied. The main blood gas alteration was severe hypercapnia with acidosis in three patients, while the other four presented critical hypoxemia unresponsive to simple oxygen supply even if delivered by high-flow Venturi mask. Four of our seven patients were discharged from hospital in satisfactory haemodynamic conditions; the remaining three died during hospitalization from refractory heart failure. In this our preliminary experience the therapeutic approach with nasal positive pressure ventilation (NPPV) and EPAP proved to be very effective to improve the signs and symptoms of acute refractory cardiogenic pulmonary edema as

  14. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    Science.gov (United States)

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  15. Influence of Changing the Diameter of the Bubble Generator Bottle and Expiratory Limb on Bubble CPAP: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Chun-Shan Wu

    2012-12-01

    Conclusion: The size and submergence depth of an expiratory limb of a CPAP circuit, the diameter of the bubble generator bottle, and the compliance of the model lung all influence the magnitude and frequency of the transmitted pressure waveform. Therefore, these factors may affect lung volume recruitment and breathing efficiency in bubble CPAP.

  16. Predictors of response to a nasal expiratory resistor device and its potential mechanisms of action for treatment of obstructive sleep apnea.

    Science.gov (United States)

    Patel, Amit V; Hwang, Dennis; Masdeu, Maria J; Chen, Guo-Ming; Rapoport, David M; Ayappa, Indu

    2011-02-15

    A one-way nasal resistor has recently been shown to reduce sleep disordered breathing (SDB) in a subset of patients with Obstructive Sleep Apnea Hypopnea Syndrome (OSAHS). The purpose of this study was to examine characteristics predictive of therapeutic response to the device and provide pilot data as to its potential mechanisms of action. PATIENTS, INTERVENTIONS, AND MEASUREMENTS: 20 subjects (15M/5F, age 54 ± 12 years, BMI 33.5 ± 5.6 kg/m²) with OSAHS underwent 3 nocturnal polysomnograms (NPSG) including diagnostic, therapeutic (with a Provent® nasal valve device), and CPAP. Additional measurements included intranasal pressures and PCO₂, closing pressures (Pcrit), and awake lung volumes in different body positions. In 19/20 patients who slept with the device, RDI was significantly reduced with the nasal valve device compared to the diagnostic NPSG (27 ± 29/h vs 49 ± 28/h), with 50% of patients having an acceptable therapeutic response. Among demographic, lung volume, or diagnostic NPSG measures or markers of collapsibility, no significant predictors of therapeutic response were found. There was a suggestion that patients with position-dependent SDB (supine RDI > lateral RDI) were more likely to have an acceptable therapeutic response to the device. Successful elimination of SDB was associated with generation and maintenance of an elevated end expiratory pressure. No single definitive mechanism of action was elucidated. The present study shows that the nasal valve device can alter SDB across the full spectrum of SDB severity. There was a suggestion that subjects with positional or milder SDB in the lateral position were those most likely to respond.

  17. Extubation success in premature infants with respiratory distress syndrome treated with bi-level nasal continuous positive airway pressure versus nasal intermittent positive pressure ventilation.

    Science.gov (United States)

    Thomas, Patricia E; LeFlore, Judy

    2013-01-01

    Infants born prematurely with respiratory distress syndrome are at high risk for complications from mechanical ventilation. Strategies are needed to minimize their days on the ventilator. The purpose of this study was to compare extubation success rates in infants treated with 2 different types of continuous positive airway pressure devices. A retrospective cohort study design was used. Data were retrieved from electronic medical records for patients in a large, metropolitan, level III neonatal intensive care unit. A sample of 194 premature infants with respiratory distress syndrome was selected, 124 of whom were treated with nasal intermittent positive pressure ventilation and 70 with bi-level variable flow nasal continuous positive airway pressure (bi-level nasal continuous positive airway pressure). Infants in both groups had high extubation success rates (79% of nasal intermittent positive pressure ventilation group and 77% of bi-level nasal continuous positive airway pressure group). Although infants in the bi-level nasal continuous positive airway pressure group were extubated sooner, there was no difference in duration of oxygen therapy between the 2 groups. Promoting early extubation and extubation success is a vital strategy to reduce complications of mechanical ventilation that adversely affect premature infants with respiratory distress syndrome.

  18. Breath-by-breath analysis of expiratory gas concentration in chickens.

    Science.gov (United States)

    Itabisashi, T

    1981-01-01

    Expiratory oxygen and carbon-dioxide concentration were analysed breath by breath in order to examine their wave forms in adult awake hens restrained in various postural positions, including supine, prone and sitting positions. Expired gas was collected at the nostril in almost all the hens. In the sitting position free from vocalization, feeding, drinking, panting, and restlessness, hens showed various forms of stable pattern of oxygen-gas curves. These forms were classified into three types, or the ascending, flat and descending types, with respect to the plateau inclination. The waves of carbon-dioxide were not always a mirror image of those of oxygen. The rate of occurrence of each type varied with the hen's postural position. The wave form was altered with the experimental body-rotation of the hen. When placed between the deflections of stable pattern, the episodes of wave deformation resembling that seen at the time of uneven pulmonary ventilation in mammals could frequently be observed in any hen's posture examined. Cardiogenic oscillation appeared on the plateau of expired-gas curves.

  19. Evaluation of a continuous-positive pressure generating system

    Directory of Open Access Journals (Sweden)

    Herrera N

    2016-03-01

    Full Text Available Nestor Herrera,1,2 Roberto Regnícoli,1,2 Mariel Murad1,2 1Neonatology Unit, Italian Hospital Garibaldi, Rosario, Argentina; 2Experimental Medicine and Surgery Unit, Italian University Institute of Rosario, Argentina Abstract: The use of systems that apply continuous-positive airway pressure by means of noninvasive methods is widespread in the neonatal care practice and has been associated with a decrease in the use of invasive mechanical ventilation, less administration of exogenous surfactant, and bronchopulmonary dysplasia. Few experimental studies on the functioning of the neonatology systems that generate continuous-positive airway pressure have been reported. A flow resistor system associated with an underwater seal resistor in a lung test model was described, and it was compared with an underwater seal threshold resistor system. Important differences in the pressures generated in the different systems studied were verified. The generation of pressure was associated with the immersion depth and the diameter of the bubble tubing. The flow resistor associated with an underwater seal, with small bubble tubing, showed no important differences in the evaluated pressures, exerting a stabilizing effect on the generated pressures. The importance of measuring the pressure generated by the different systems studied was verified, due to the differences between the working pressures set and the pressures measured. Keywords: continuous-positive pressure, flow and threshold resistor, BCPAP

  20. Surfactant impairment after mechanical ventilation with large alveolar surface area changes and effects of positive end-expiratory pressure

    NARCIS (Netherlands)

    S.J.C. Verbrugge (Serge); S.H. Bohm; D.A.M.P.J. Gommers (Diederik); L.J.I. Zimmermann (Luc); B.F. Lachmann (Burkhard)

    1998-01-01

    textabstractWe have assessed the effects of overinflation on surfactant function and composition in rats undergoing ventilation for 20 min with 100% oxygen at a peak inspiratory pressure of 45 cm H2O, with or without PEEP 10 cm H2O (groups 45/10 and 45/0, respectively).

  1. Effect of pilates method on inspiratory and expiratory muscle strength in the elderly

    Directory of Open Access Journals (Sweden)

    Beatriz Mendes Tozim

    2018-03-01

    Full Text Available With aging, the respiratory muscle strength decreases and the pilates method is a technique that uses respiration as one of its principles. The present study has the aim of analyzing the influence of the pilates method on respiratory muscle strength in older women. For the evaluation of respiratory muscle strength (inspiratory and expiratory, manovacuometer was used. Thirty-one older women were divided into two groups: 14 participated in the pilates group and 17 in the control group. Participants of the pilates group performed 16 sessions of pilates method with an hour of training, twice week for eight weeks. The control group participated in four educational lectures for eight weeks. For statistical analysis, Shapiro-Wilk, ANOVA for repeated measures (p <0.05 and Cohen’s D index were performed. The results showed significant difference and the mean effect for the Cohen’s D index expiratory muscle strength of the pilates group when comparing before (69.71 ± 25.48 and after (85.23 ± 22.21 training (p<0.05 with an increase of 23%. The results of inspiratory muscle strength were not significant but presented an average effect for the Cohen’s D index for the pilates group before (69.71 ± 35.46 and after (88.00 ± 34.87 training, with an increase of 27%. The control group did not present significant differences for the variables evaluated. It could be concluded that the pilates method is effective in improving expiratory muscle strength and provides positive effects on the increase in inspiratory muscle strength.

  2. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.

    Science.gov (United States)

    Yu, Chun-Hsiang; Su, Po-Lan; Lin, Wei-Chieh; Lin, Sheng-Hsiang; Chen, Chang-Wen

    2015-02-01

    Late inspiratory rise in airway pressure (LIRAP, Paw/ΔT) caused by inspiratory muscle relaxation or expiratory muscle contraction is frequently seen during pressure support ventilation (PSV), although the modulating factors are unknown. We investigated the effects of respiratory mechanics (normal, obstructive, restrictive, or mixed), inspiratory effort (-2, -8, or -15 cm H2O), flow cycle criteria (5-40% peak inspiratory flow), and duration of inspiratory muscle relaxation (0.18-0.3 s) on LIRAP during PSV using a lung simulator and 4 types of ventilators. LIRAP occurred with all lung models when inspiratory effort was medium to high and duration of inspiratory muscle relaxation was short. The normal lung model was associated with the fastest LIRAP, whereas the obstructive lung model was associated with the slowest. Unless lung mechanics were normal or mixed, LIRAP was unlikely to occur when inspiratory effort was low. Different ventilators were also associated with differences in LIRAP speed. Except for within the restrictive lung model, changes in flow cycle level did not abolish LIRAP if inspiratory effort was medium to high. Increased duration of inspiratory relaxation also led to the elimination of LIRAP. Simulation of expiratory muscle contraction revealed that LIRAP occurred only when expiratory muscle contraction occurred sometime after the beginning of inspiration. Our simulation study reveals that both respiratory resistance and compliance may affect LIRAP. Except for under restrictive lung conditions, LIRAP is unlikely to be abolished by simply lowering flow cycle criteria when inspiratory effort is strong and relaxation time is rapid. LIRAP may be caused by expiratory muscle contraction when it occurs during inspiration. Copyright © 2015 by Daedalus Enterprises.

  3. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  4. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    International Nuclear Information System (INIS)

    Kitchen, M J; Habib, A; Lewis, R A; Fouras, A; Dubsky, S; Wallace, M J; Hooper, S B

    2010-01-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  5. Comparação entre inspirometria de incentivo e pressão positiva expiratória na função pulmonar após cirurgia bariátrica Comparison between incentive spirometry and expiratory positive airway pressure on pulmonary function after bariatric surgery

    Directory of Open Access Journals (Sweden)

    Marcela C. Barbalho-Moulim

    2009-06-01

    Full Text Available O objetivo deste estudo foi comparar o efeito da pressão positiva expiratória (EPAP, na sigla em inglês e da inspirometria de incentivo a fluxo sobre a função pulmonar após o bypass gástrico em Y de Roux por videolaparoscopia. Participaram 28 mulheres, não-tabagistas e não-pneumopatas, com índice de massa corporal entre 35 e 50 kg/m², submetidas à cirurgia bariátrica. Todas foram avaliadas por espirometria, cirtometria toracoabdominal e quanto à mobilidade diafragmática no pré e segundo dia de pós-operatório (o tempo de internação foi de 2 dias. Foram divididas em dois grupos, GI - grupo inspirômetro (n=13 e GE, grupo EPAP (n=15. A fisioterapia foi iniciada no dia da cirurgia, cada técnica, inspirometria ou EPAP, com duração de 15 minutos; a fisioterapia motora foi padronizada para ambos os grupos. No pós-operatório, houve redução similar nos dois grupos das variáveis: capacidade vital, volume de reserva inspiratório, capacidade vital forçada e ventilação voluntária máxima. Não houve alteração nos valores do volume corrente no GI e volume de reserva expiratório no GE. A mobilidade diafragmática e a mobilidade toracoabdominal foram menos prejudicadas no GI. No pós-operatório da cirurgia bariátrica por videolaparoscopia, a inspirometria de incentivo a fluxo exerceu melhores efeitos na manutenção do volume corente, na mobilidade diafragmática e toracoabdominal, enquanto a EPAP foi mais eficaz no restabelecimento do volume de reserva expiratório.The aim of this study was to compare the effect of expiratory positive airway pressure (EPAP and flow-oriented incentive spirometry on pulmonary function after laparoscopic Roux-en-Y gastric bypass surgery. Twenty-eight non-smoking women, with no lung disease and body mass index of 35 to 50 kg/m², undergoing laparoscopic gastric bypass surgery (hospitalized for two days were assessed by spirometry, thoracoabdominal cirtometry and as to diaphragmatic motion

  6. Continuous positive airway pressure therapy: new generations.

    LENUS (Irish Health Repository)

    Garvey, John F

    2010-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management.

  7. Continuous positive airway pressure therapy: new generations.

    LENUS (Irish Health Repository)

    Garvey, John F

    2012-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management.

  8. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    Science.gov (United States)

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  9. The respiratory drive to thoracic motoneurones in the cat and its relation to the connections from expiratory bulbospinal neurones

    Science.gov (United States)

    Saywell, S A; Anissimova, N P; Ford, T W; Meehan, C F; Kirkwood, P A

    2007-01-01

    The descending control of respiratory-related motoneurones in the thoracic spinal cord remains the subject of some debate. In this study, direct connections from expiratory bulbospinal neurones to identified motoneurones were investigated using spike-triggered averaging and the strengths of connection revealed were related to the presence and size of central respiratory drive potentials in the same motoneurones. Intracellular recordings were made from motoneurones in segments T5–T9 of the spinal cord of anaesthetized cats. Spike-triggered averaging from expiratory bulbospinal neurones in the caudal medulla revealed monosynaptic EPSPs in all groups of motoneurones, with the strongest connections to expiratory motoneurones with axons in the internal intercostal nerve. In the latter, connection strength was similar irrespective of the target muscle (e.g. external abdominal oblique or internal intercostal) and the EPSP amplitude was positively correlated with the amplitude of the central respiratory drive potential of the motoneurone. For this group, EPSPs were found in 45/83 bulbospinal neurone/motoneurone pairs, with a mean amplitude of 40.5 μV. The overall strength of the connection supports previous measurements made by cross-correlation, but is about 10 times stronger than that reported in the only previous similar survey to use spike-triggered averaging. Calculations are presented to suggest that this input alone is sufficient to account for all the expiratory depolarization seen in the recorded motoneurones. However, extra sources of input, or amplification of this one, are likely to be necessary to produce a useful motoneurone output. PMID:17204500

  10. Noninvasive Positive Pressure Ventilatory Support Begins During Sleep.

    Science.gov (United States)

    Bach, John R

    2017-12-01

    The goal of sleep doctors has been to titrate away apneas and hypopneas using noninvasive ventilation, a term that has become synonymous with continuous positive airway pressure and bilevel positive airway pressure at the lowest effective bilevel settings. It is now time to appreciate noninvasive ventilatory support as an alternative to invasive mechanical ventilation. This article discusses mechanisms of action, two paradigms, and ancillary techniques for noninvasive ventilatory support. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Pressão expiratória positiva na via aérea por máscara facial na hemodinâmica de pós-operatórios cardíacos Expiratory positive airway pressure in postoperative cardiac hemodynamics

    Directory of Open Access Journals (Sweden)

    Ana Claudia Borges dos Santos Sena

    2010-10-01

    Full Text Available FUNDAMENTOS: A pressão expiratória positiva na via aérea por máscara facial (EPAP é utilizada no pós-operatório de cirurgias cardíacas, entretanto, seus efeitos hemodinâmicos não foram claramente estudados. OBJETIVO: Avaliar as alterações hemodinâmicas causadas pela EPAP em pacientes pós-cirurgia cardíaca monitorados por cateter de Swan-Ganz. MÉTODOS: Foram incluídos no estudo, pacientes no primeiro ou segundo pós-operatório de cirurgia cardíaca, estáveis hemodinamicamente e com cateter de Swan-Ganz. Eles foram avaliados em repouso e após o uso de 10 cmH2O de EPAP, de forma randomizada. As variáveis estudadas foram: saturação de oxigênio, frequências cardíaca e respiratória, pressões arteriais médias sistêmica e pulmonar (PAM e PAMP, pressões venosa central (PVC e de oclusão da atéria pulmonar (POAP, débito e índice cardíacos, e resistências vasculares sistêmica e pulmonar. Os pacientes foram divididos em subgrupos (com fração de ejeção 50% e os dados foram comparados por teste t e ANOVA. RESULTADOS: Vinte e oito pacientes foram estudados (22 homens, idade média 68 ± 11 anos. Comparando o período de repouso versus EPAP, as alterações observadas foram: POAP (11,9 ± 3,8 para 17,1 ± 4,9 mmHg, p BACKGROND: Expiratory positive airway pressure (EPAP is used in after cardiac surgeries. However, its hemodynamic effects have not been clearly studied. OBJECTIVE: To evaluate the hemodynamic changes caused by EPAP in patients after cardiac surgery monitored by Swan-Ganz. METHODS: Patients at the first or second cardiac surgery postoperative period hemodynamically stable with a Swan-Ganz catheter were included in the study. They were assessed at rest and after using 10 cmH2O EPAP at random. The variables studied were: oxygen saturation, heart rate and respiratory rate, mean artery pressures and pulmonary artery mean pressures (MAP and PAMP, central venous pressure (CVP and pulmonary capillary wedge pressure

  12. Noninvasive Positive Pressure Ventilation or Conventional Mechanical Ventilation for Neonatal Continuous Positive Airway Pressure Failure

    Directory of Open Access Journals (Sweden)

    Zohreh Badiee

    2014-01-01

    Full Text Available Background: The aim of this study was to assess the success rate of nasal intermittent positive pressure ventilation (NIPPV for treatment of continuous positive airway pressure (CPAP failure and prevention of conventional ventilation (CV in preterm neonates. Methods: Since November 2012 to April 2013, a total number of 55 consecutive newborns with gestational ages of 26-35 weeks who had CPAP failure were randomly assigned to one of the two groups. The NIPPV group received NIPPV with the initial peak inspiratory pressure (PIP of 16-20 cmH 2 O and frequency of 40-60 breaths/min. The CV group received PIP of 12-20 cmH 2 O and frequency of 40-60 breaths/min. Results: About 74% of newborns who received NIPPV for management of CPAP failure responded to NIPPV and did not need intubation and mechanical ventilation. Newborns with lower postnatal age at entry to the study and lower 5 min Apgar score more likely had NIPPV failure. In addition, treatment failure was higher in newborns who needed more frequent doses of surfactant. Duration of oxygen therapy was 9.28 days in CV group and 7.77 days in NIPPV group (P = 0.050. Length of hospital stay in CV group and NIPPV groups were 48.7 and 41.7 days, respectively (P = 0.097. Conclusions: NIPPV could decrease the need for intubation and mechanical ventilation in preterm infants with CPAP failure.

  13. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce.......A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  14. Improvised bubble continuous positive airway pressure (BCPAP ...

    African Journals Online (AJOL)

    Improvised bubble continuous positive airway pressure (BCPAP) device at the National Hospital Abuja gives immediate improvement in respiratory rate and oxygenation in neonates with respiratory distress.

  15. Running on a lower-body positive pressure treadmill

    DEFF Research Database (Denmark)

    Raffalt, Peter C; Hovgaard-Hansen, Line; Jensen, Bente Rona

    2013-01-01

    This study investigated maximal oxygen consumption (VO2max) and time to exhaustion while running on a lower-body positive pressure treadmill (LBPPT) at normal body weight (BW) as well as how BW support affects respiratory responses, ground reaction forces, and stride characteristics.......This study investigated maximal oxygen consumption (VO2max) and time to exhaustion while running on a lower-body positive pressure treadmill (LBPPT) at normal body weight (BW) as well as how BW support affects respiratory responses, ground reaction forces, and stride characteristics....

  16. The respiratory drive to thoracic motoneurones in the cat and its relation to the connections from expiratory bulbospinal neurones

    DEFF Research Database (Denmark)

    Saywell, S A; Anissimova, N P; Ford, T W

    2007-01-01

    of connection revealed were related to the presence and size of central respiratory drive potentials in the same motoneurones. Intracellular recordings were made from motoneurones in segments T5-T9 of the spinal cord of anaesthetized cats. Spike-triggered averaging from expiratory bulbospinal neurones...... in the caudal medulla revealed monosynaptic EPSPs in all groups of motoneurones, with the strongest connections to expiratory motoneurones with axons in the internal intercostal nerve. In the latter, connection strength was similar irrespective of the target muscle (e.g. external abdominal oblique or internal...... intercostal) and the EPSP amplitude was positively correlated with the amplitude of the central respiratory drive potential of the motoneurone. For this group, EPSPs were found in 45/83 bulbospinal neurone/motoneurone pairs, with a mean amplitude of 40.5 microV. The overall strength of the connection supports...

  17. Positional effects on distribution of ventilation in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shim, C.; Chun, K.J.; Williams, M.H. Jr.; Blaufox, M.D.

    1986-01-01

    Ventilation is distributed predominantly to the dependent lung in normal persons in the decubitus position. We evaluated the distribution of ventilation in four patients with mild-to-moderate chronic obstructive pulmonary disease using 81mKr gas. Patients were tested in the sitting and right and left decubitus positions with and without the application of positive end expiratory pressure (PEEP). In contrast to findings in controls, ventilation was predominantly distributed to the nondependent lung in patients in the decubitus position. Mean ventilation in the right lung decreased from 51% of the total in the sitting position to 31% in the right decubitus position; it increased with the application of 10 cm PEEP. Reduced ventilation in the dependent lung most likely is caused by closure of the airways after a decrease in volume. Application of PEEP resulted in increased lung volume and preferential distribution of ventilation to the dependent lung

  18. Proportional positive airway pressure: a new concept to treat obstructive sleep apnoea.

    Science.gov (United States)

    Juhász, J; Becker, H; Cassel, W; Rostig, S; Peter, J H

    2001-03-01

    Proportional positive airway pressure (PPAP) was designed to optimize airway pressure for the therapy of obstructive sleep apnoea (OSA). In a randomized crossover prospective study, the clinical feasibility of PPAP and its immediate effects on the breathing disorder and sleep in comparison with continuous positive airway pressure (CPAP) was evaluated. Twelve patients requiring CPAP therapy underwent CPAP and PPAP titration in a random order. Obstructive and mixed respiratory events could be completely abolished with both forms of treatment. This efficacy could be achieved at a significantly lower mean mask pressure during PPAP titration (8.45+/-2.42 cmH2O) compared to CPAP (9.96+/-2.7 cmH2O) (p=0.002). The mean minimal arterial oxygen saturation (Sa,O2) (82.8+/-6.5%) on the diagnostic night increased significantly (pPPAP titration. Total sleep time, slow wave sleep and rapid eye movement (REM) sleep increased significantly by the same amount during both CPAP and PPAP titration (pPPAP titration night, four patients did not have a preference, and two patients preferred CPAP. The present data show that proportional positive airway pressure is as effective as continuous positive airway pressure in eliminating obstructive events and has the same immediate effect on sleep. The lower average mask pressure during proportional positive airway pressure implies potential advantages compared to continuous positive airway pressure. Proportional positive airway pressure presents a new effective therapeutic approach to obstructive sleep apnoea.

  19. Alveolar Tidal recruitment/derecruitment and Overdistension During Four Levels of End-Expiratory Pressure with Protective Tidal Volume During Anesthesia in a Murine Lung-Healthy Model.

    Science.gov (United States)

    Soares, Joao Henrique Neves; Carvalho, Alysson Roncally; Bergamini, Bruno Curty; Gress, Maria Alice Kuster; Jandre, Frederico Caetano; Zin, Walter Araujo; Giannella-Neto, Antonio

    2018-06-01

    We compared respiratory mechanics between the positive end-expiratory pressure of minimal respiratory system elastance (PEEP minErs ) and three levels of PEEP during low-tidal-volume (6 mL/kg) ventilation in rats. Twenty-four rats were anesthetized, paralyzed, and mechanically ventilated. Airway pressure (P aw ), flow (F), and volume (V) were fitted by a linear single compartment model (LSCM) P aw (t) = E rs  × V(t) + R rs  × F(t) + PEEP or a volume- and flow-dependent SCM (VFDSCM) P aw (t) = (E 1  + E 2  × V(t)) × V(t) + (K 1  + K 2  × |F(t)|) × F(t) + PEEP, where E rs and R rs are respiratory system elastance and resistance, respectively; E 1 and E 2 × V are volume-independent and volume-dependent E rs , respectively; and K 1 and K 2  × F are flow-independent and flow-dependent R rs , respectively. Animals were ventilated for 1 h at PEEP 0 cmH 2 O (ZEEP); PEEP minErs ; 2 cmH 2 O above PEEP minErs (PEEP minErs+2 ); or 4 cmH 2 O above PEEP minErs (PEEP minErs+4 ). Alveolar tidal recruitment/derecruitment and overdistension were assessed by the index %E 2  = 100 × [(E 2  × V T )/(E 1  + |E 2 | × V T )], and alveolar stability by the slope of E rs (t). %E 2 varied between 0 and 30% at PEEP minErs in most respiratory cycles. Alveolar Tidal recruitment/derecruitment (%E 2   30) were predominant in the absence of PEEP and in PEEP levels higher than PEEP minErs , respectively. The slope of E rs (t) was different from zero in all groups besides PEEP minErs+4 . PEEP minErs presented the best compromise between alveolar tidal recruitment/derecruitment and overdistension, during 1 h of low-V T mechanical ventilation.

  20. Experimental intra-abdominal hypertension influences airway pressure limits for lung protective mechanical ventilation.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Cortes-Puentes, Luis A; Adams, Alexander B; Anderson, Christopher P; Marini, John J; Dries, David J

    2013-06-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) may complicate monitoring of pulmonary mechanics owing to their impact on the respiratory system. However, recommendations for mechanical ventilation of patients with IAH/ACS and the interpretation of thoracoabdominal interactions remain unclear. Our study aimed to characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Nine deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume (VT) of 10 mL/kg, frequency of 15, inspiratory-expiratory ratio of 1:2, and PEEP of 1 and 10 cm H2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was placed in the peritoneal cavity, and IAP levels of 5, 10, 15, 20, and 25 mm Hg were applied, using a continuous positive airway pressure system. At each IAP level, PBLAD and airway pressure measurements were performed during both PEEP1 and PEEP10. PBLAD increased as experimental IAP rose (y = 0.83x + 0.5; R = 0.98; p < 0.001 at PEEP1). Minimal underestimation of IAP by PBLAD was observed (-2.5 ± 0.8 mm Hg at an IAP of 10-25 mm Hg). Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. Approximately 50% of the PBLAD (in cm H2O) was reflected by changes in PPLAT, regardless of the PEEP level applied. Increasing IAP did not influence hemodynamics at any level of IAP generated. With minimal underestimation, PBLAD measurements closely correlated with experimentally regulated IAP, independent of the PEEP level applied. For each PEEP level applied, a constant proportion (approximately 50%) of measured PBLAD (in cm H2O) was reflected in PPLAT. A higher safety threshold for PPLAT should be considered in the setting of IAH/ACS as the clinician considers changes in VT. A strategy of reducing VT to cap PPLAT at widely recommended values may not be

  1. Effects of body position and sex group on tongue pressure generation.

    Science.gov (United States)

    Dietsch, Angela M; Cirstea, Carmen M; Auer, Ed T; Searl, Jeff P

    2013-11-01

    Fine control of orofacial musculature is necessary to precisely accelerate and decelerate the articulators across exact distances for functional speech and coordinated swallows (Amerman & Parnell, 1990; Benjamin, 1997; Kent, Duffy, Slama, Kent, & Clift, 2001). Enhanced understanding of neural control for such movements could clarify the nature of and potential remediation for some dysarthrias and other orofacial myofunctional impairments. Numerous studies have measured orolingual force and accuracy during speech and nonspeech tasks, but have focused on young adults, maximum linguapalatal pressures, and upright positioning (O'Day, Frank, Montgomery, Nichols, & McDade, 2005; Solomon & Munson, 2004; Somodi, Robin, & Luschei, 1995; Youmans, Youmans, & Stierwalt, 2009). Patients' medical conditions or testing procedures such as concurrent neuroimaging may preclude fully upright positioning during oral motor assessments in some cases. Since judgments about lingual strength and coordination can influence clinical decisions regarding the functionality of swallowing and speech, it is imperative to understand any effects of body positioning differences. In addition, sex differences in the control of such tasks are not well defined. Therefore, this study evaluated whether pressures exerted during tongue movements differ in upright vs. supine body position in healthy middle-aged men and women. Twenty healthy middle-aged adults compressed small air-filled plastic bulbs in the oral cavity at predetermined fractions of task-specific peak pressure in a randomized block design. Tasks including phoneme repetitions and nonspeech isometric contractions were executed in upright and supine positions. Participants received continuous visual feedback regarding targets and actual exerted pressures. Analyses compared average pressure values for each subject, task, position, and effort level. Speech-like and nonspeech tongue pressures did not differ significantly across body position or sex

  2. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin; Choi, Seok Jin; Goo, Jin Mo

    2000-01-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary

  3. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin [Donga University College of Medicine, Pusan (Korea, Republic of); Choi, Seok Jin [Inje University College of Medicine, Gimhae (Korea, Republic of); Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  4. [Possibilities of bi-level positive pressure ventilation in chronic hypoventilation].

    Science.gov (United States)

    Saaresranta, Tarja; Anttalainen, Ulla; Polo, Olli

    2011-01-01

    During the last decade, noninvasive bi-level positive pressure ventilation has enabled respiratory support in inpatient wards and at home. In many cases, a bi-level airway pressure ventilator can be used to avoid artificial airway and respirator therapy, and may shorten hospital stay and save costs. The treatment alleviates the patient's dyspnea and fatigue, whereby the quality of life improves, and in certain situations also the life span increases. The implementation of bi-level positive pressure ventilation by the physician requires knowledge of the basics of respiratory physiology and familiarization with the bi-level airway pressure ventilator.

  5. Asystole following positive pressure insufflation of right pleural cavity: a case report

    Directory of Open Access Journals (Sweden)

    Konia Mojca R

    2011-06-01

    Full Text Available Abstract Introduction Adverse hemodynamic effects with severe bradycardia have been previously reported during positive pressure insufflation of the right thoracic cavity in humans. To the best of our knowledge, this is the first report of asystole during thoracoscopic surgery with positive pressure insufflation. Case presentation A 63-year-old Caucasian woman developed asystole at the onset of positive pressure insufflation of her right hemithorax during a thoracoscopic single-lung ventilation procedure. Immediate deflation of pleural cavity, intravenous glycopyrrolate and atropine administration returned her heart rhythm to normal sinus rhythm. The surgery proceeded in the absence of positive pressure insufflation without any further complications. Conclusions We discuss the proposed mechanisms of hemodynamic instability with positive pressure thoracic insufflation, and anesthetic and insufflation techniques that decrease the likelihood of adverse hemodynamic events.

  6. The importance of clinical monitoring for compliance with Continuous Positive Airway Pressure.

    Science.gov (United States)

    Pelosi, Lucas B; Silveira, Mariana L C; Eckeli, Alan L; Chayamiti, Emilia M P C; Almeida, Leila A; Sander, Heidi H; Küpper, Daniel S; Valera, Fabiana C P

    Obstructive sleep apnea syndrome is currently a public health problem of great importance. When misdiagnosed or improperly treated, it can lead to serious consequences on patients' quality of life. The gold standard treatment for cases of obstructive sleep apnea syndrome, especially in mild to severe and symptomatic cases, is continuous positive airway pressure therapy. Compliance with continuous positive airway pressure therapy is directly dependent on the active participation of the patient, which can be influenced by several factors. The objective of this study is to describe the factors related to compliance with continuous positive airway pressure therapy, and to analyze which associated factors directly influence the efficiency of the treatment. Patients who received continuous positive airway pressure therapy through the Municipal Health Department of the city of Ribeirão Preto were recruited. A structured questionnaire was administered to the patients. Compliance with continuous positive airway pressure therapy was assessed by average hours of continuous positive airway pressure therapy usage per night. Patients with good compliance (patients using continuous positive airway pressure therapy ≥4h/night) were compared to those with poor compliance (patients using <4h/night). 138 patients were analyzed: 77 (55.8%) were considered compliant while 61 (44.2%) were non-compliant. The comparison between the two groups showed that regular monitoring by a specialist considerably improved compliance with continuous positive airway pressure therapy (odds ratio, OR=2.62). Compliance with continuous positive airway pressure therapy is related to educational components, which can be enhanced with continuous and individualized care to patients with obstructive sleep apnea syndrome. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  7. Positioning bedridden patients to reduce interface pressures over the sacrum and great trochanter.

    Science.gov (United States)

    Yoshikawa, Y; Maeshige, N; Sugimoto, M; Uemura, M; Noguchi, M; Terashi, H

    2015-07-01

    In this study, we evaluated the effect of hip-joint rotation on the interface pressure over the sacrum and greater trochanter with a new protocol for positioning of bedridden elderly patients. The interface pressure values over the sacrum and greater trochanter in bedridden patients were evaluated. These were collected in the supine position, 90° lateral position, and 30° and 40° laterally inclined positions with external rotation or neutral positioning of the hip joint. Each interface pressure was assessed with a device measuring pressure distribution, after which, the peak pressure index (PPI) was calculated. In the 17 patients examined, the PPI over the sacrum in the supine position was significantly greater than that in other positions. In the 30° and 40° laterally inclined positions, the PPIs over the greater trochanter were significantly lower in the neutral position of the hip joint compared with those in the external rotation position. Our findings revealed the effects of hip-joint rotation on the interface pressure for the greater trochanter, possibly due to the increased distance between the greater trochanter and the sacrum caused by neutral position of the hip joint. The results demonstrate that it is to best place the hip joint in a neutral position when the legs are in contact with the bed in order to distribute the pressure over the greater trochanter in the 30° and 40° laterally inclined positions. These results can be applied to the clinical setting to improve patient positioning and decrease pressure ulcers. The authors declare that they have no competing financial interests.

  8. Improvised bubble continuous positive airway pressure

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2014-08-15

    Aug 15, 2014 ... Abstract: Background: Prematur- ity accounts for 25% of Neonatal mortality in Nigeria and Respira- tory Distress Syndrome is respon- sible for half of these deaths. Introducing continuous positive airway pressure for the treatment of RDS in Nigeria where health care financing is predominantly out-of-pocket ...

  9. High resolution CT in cystic fibrosis--the contribution of expiratory scans

    International Nuclear Information System (INIS)

    Dorloechter, Ludger; Nes, Harald; Fluge, Gjermund; Rosendahl, Karen

    2003-01-01

    Introduction: The use of high-resolution computed tomography (HRCT) is well accepted as an accurate method for evaluation of lung parenchyma in cystic fibrosis (CF). Several scoring methods exist and, in common, all are based on HRCT findings during inspiration alone. Objective: To examine whether expiratory HRCT scans could add information about the degree of mosaic perfusion in patients with CF. Methods and patients: Pulmonary HRCT was performed in 17 CF patients (median age of 12 years) with 1-mm thin sections and 10-mm intervals during inspiration, followed by 1-mm thin sections with 20-mm intervals during expiration. HRCT was scored by using a modified Bhalla method. Results: The mean HRCT score was 8.2. Out of 17 patients, 11 (65%) demonstrated a pathological mosaic perfusion in expiration, while only three patients showed mosaic perfusion in inspiration. The degree of expiratory mosaic perfusion was graded as severe in nine patients and moderate in two patients. There was a significant correlation between our modified HRCT score and lung function, as measured by forced expiratory volume in 1 s (FEV1% predicted, P<0.01). Conclusion: Mosaic perfusion in expiration was a common pathological HRCT finding in our study group. The clinical significance of this finding needs further evaluation

  10. Atmospheric pressure loading effects on Global Positioning System coordinate determinations

    Science.gov (United States)

    Vandam, Tonie M.; Blewitt, Geoffrey; Heflin, Michael B.

    1994-01-01

    Earth deformation signals caused by atmospheric pressure loading are detected in vertical position estimates at Global Positioning System (GPS) stations. Surface displacements due to changes in atmospheric pressure account for up to 24% of the total variance in the GPS height estimates. The detected loading signals are larger at higher latitudes where pressure variations are greatest; the largest effect is observed at Fairbanks, Alaska (latitude 65 deg), with a signal root mean square (RMS) of 5 mm. Out of 19 continuously operating GPS sites (with a mean of 281 daily solutions per site), 18 show a positive correlation between the GPS vertical estimates and the modeled loading displacements. Accounting for loading reduces the variance of the vertical station positions on 12 of the 19 sites investigated. Removing the modeled pressure loading from GPS determinations of baseline length for baselines longer than 6000 km reduces the variance on 73 of the 117 baselines investigated. The slight increase in variance for some of the sites and baselines is consistent with expected statistical fluctuations. The results from most stations are consistent with approximately 65% of the modeled pressure load being found in the GPS vertical position measurements. Removing an annual signal from both the measured heights and the modeled load time series leaves this value unchanged. The source of the remaining discrepancy between the modeled and observed loading signal may be the result of (1) anisotropic effects in the Earth's loading response, (2) errors in GPS estimates of tropospheric delay, (3) errors in the surface pressure data, or (4) annual signals in the time series of loading and station heights. In addition, we find that using site dependent coefficients, determined by fitting local pressure to the modeled radial displacements, reduces the variance of the measured station heights as well as or better than using the global convolution sum.

  11. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  12. Association between driving pressure and development of postoperative pulmonary complications in patients undergoing mechanical ventilation for general anaesthesia: a meta-analysis of individual patient data.

    Science.gov (United States)

    Neto, Ary Serpa; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; El-Tahan, Mohamed R; Ghamdi, Abdulmohsin A Al; Günay, Ersin; Jaber, Samir; Kokulu, Serdar; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Ranieri, V Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Amato, Marcelo B P; Costa, Eduardo L V; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2016-04-01

    Protective mechanical ventilation strategies using low tidal volume or high levels of positive end-expiratory pressure (PEEP) improve outcomes for patients who have had surgery. The role of the driving pressure, which is the difference between the plateau pressure and the level of positive end-expiratory pressure is not known. We investigated the association of tidal volume, the level of PEEP, and driving pressure during intraoperative ventilation with the development of postoperative pulmonary complications. We did a meta-analysis of individual patient data from randomised controlled trials of protective ventilation during general anesthaesia for surgery published up to July 30, 2015. The main outcome was development of postoperative pulmonary complications (postoperative lung injury, pulmonary infection, or barotrauma). We included data from 17 randomised controlled trials, including 2250 patients. Multivariate analysis suggested that driving pressure was associated with the development of postoperative pulmonary complications (odds ratio [OR] for one unit increase of driving pressure 1·16, 95% CI 1·13-1·19; pprotective ventilation on development of pulmonary complications (p=0·027). In two studies that compared low with high PEEP during low tidal volume ventilation, an increase in the level of PEEP that resulted in an increase in driving pressure was associated with more postoperative pulmonary complications (OR 3·11, 95% CI 1·39-6·96; p=0·006). In patients having surgery, intraoperative high driving pressure and changes in the level of PEEP that result in an increase of driving pressure are associated with more postoperative pulmonary complications. However, a randomised controlled trial comparing ventilation based on driving pressure with usual care is needed to confirm these findings. None. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    Science.gov (United States)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  14. Regional specific mean expiratory gas flow from Slmsub(Kr) equilibrium inhalation data

    International Nuclear Information System (INIS)

    Hamilton, D.; Causer, D.A.; McIntosh, J.A.; Godfrey, K.R.

    1985-01-01

    A new method of analysing the data available from routine sup(81m) Kr equilibrium inhalation investigations has been developed. The data for analysis are acquired from a gamma camera in the form of a sequential series of images from which multiple breath activity-time curves are generated for eight regions in the lung. The method is based on a description of the behaviour of the radioactive gas in the lung using a mathematical model. Values of specific mean expiratory gas flow, that is mean expiratory gas flow per unit lung volume, are calculated from the application of the model to the expiratory phase only only of a single breath activity-time curve which is generated from the multiple breath activity-time curve using post-acquisition gating. This method overcomes the problem of non-uniform inspiratory concentration of tracer gas experienced in previously reported techniques of analysing inhalation data obtained using poorly soluble radioactive gases. The model is shown, in simulation studies, to be an adequate description of the behaviour of radioactive gas in the lung and the analysis technique is shown, in clinical studies, to be both reproducible and sensitive to disease state. (orig.)

  15. Abdominal wall reconstruction for large incisional hernia restores expiratory lung function

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Backer, Vibeke; Jorgensen, Lars N

    2017-01-01

    BACKGROUND: Respiratory complications secondary to intermittent intra-abdominal hypertension and/or atelectasis are common after abdominal wall reconstruction for large incisional hernias. It is unknown if the respiratory function of this patient group is affected long term or impairs activities...... of daily living. We hypothesized that abdominal wall reconstruction for large incisional hernia would not lead to improved, long-term pulmonary function or respiratory quality of life. METHODS: Eighteen patients undergoing open abdominal wall reconstruction with mesh for a large incisional hernia...... (horizontal fascial defect width >10 cm) were compared with 18 patients with an intact abdominal wall who underwent colorectal resection. Patients were examined pre- and 1-year postoperatively. Examined measures included forced vital capacity, forced expiratory volume in first second, peak expiratory flow...

  16. Noninvasive positive pressure ventilation enhances the effects of aerobic training on cardiopulmonary function.

    Directory of Open Access Journals (Sweden)

    Takashi Moriki

    Full Text Available The purpose of this study was to determine the effect of aerobic training under noninvasive positive pressure ventilation (NPPV on maximal oxygen uptake ([Formula: see text].Ten healthy young male volunteers participated in the study. Before the training, stroke volume (SV and cardiac output (CO were measured in all subjects under 0, 4, 8, and 12 cmH2O NPPV at rest. Then, the subjects exercised on a cycle ergometer at 60% of pre-training [Formula: see text] for 30 min daily for 5 consecutive days with/without NPPV. The 5-day exercise protocol was repeated after a three-week washout period without/with NPPV. The primary endpoint was changes in [Formula: see text]. The secondary endpoints were changes in SV, CO, maximum heart rate (HRmax, maximum respiratory rate (RRmax, maximum expiratory minute volume (VEmax and the percent change in plasma volume (PV.NPPV at 12 cmH2O significantly reduced SV and CO at rest. [Formula: see text] significantly increased after 5 days training with and without NPPV, but the magnitude of increase in [Formula: see text] after training under 12 cmH2O NPPV was significantly higher than after training without NPPV. VEmax significantly increased after training under NPPV, but not after training without NPPV. HRmax and RRmax did not change during training irrespective of NPPV. The percent change in PV was similar between training with and without NPPV. The 5-day training program with NPPV resulted in greater improvement in [Formula: see text] than without NPPV.Aerobic training under NPPV has add-on effects on [Formula: see text] and exercise-related health benefits in healthy young men.

  17. Factors influencing peak expiratory flow in teenage boys | van ...

    African Journals Online (AJOL)

    Background. Peak expiratory flow (PEF) is a useful measure of pulmonary health status and is frequently utilised in asthm, management. Reduction in PEF is usually indicative of onset (of asthma symptoms. However, use can be made of PEF values only if normal values are known. The definition of normal range is always ...

  18. predicted peak expiratory flow in human and the clinical implication ...

    African Journals Online (AJOL)

    DR. AMINU

    predicted PEF varied widely across formulae and choice of a particular formula may alter guideline- base care. This work has therefore accepted a recently published population-base equation proposed as the reference standard for future asthma guidelines. Keywords: Peak expiratory flow, Asthma, Practice guidelines, ...

  19. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  20. Knowledge, attitude and practice of nurses toward peak expiratory ...

    African Journals Online (AJOL)

    Background: Peak expiratory flow meter (PEFM) is an easy to use, relatively cheap device that can be used for guiding management of bronchial asthma by the patients at home according to a preset plan by health care workers. Objective: The aim of the study is to reveal the extent of knowledge and perception of nurses ...

  1. Positive muon diffusion in iron and nickel pressure dependence

    CERN Document Server

    Butz, T; Dufresne, J F; Hartmann, O; Karlsson, E; Lindgren, B; Longobardi, R; Norlin, L O; Pezzetti, J P; Yaouanc, A

    1980-01-01

    The hyperfine field B/sub hf/ at positive muon ( mu /sup +/) in iron and nickel was previously found. Exhibits marked deviations from the bulk magnetization as a function of temperature. For substitutional impurities in Fe and Ni matrices the volume dependence of B/sub hf/ has been considered as a possible reason for such deviations. Therefore the authors have measured at CERN the local magnetic field at mu /sup +/, B/sub mu /, in high purity polycrystalline Fe and Ni samples at room temperature and at pressures up to 7 kbar by the positive muon spin rotation ( mu /sup +/ SR) technique. To their knowledge, this is the first mu /sup +/SR experiment performed under hydrostatic pressure. The authors observe a linear pressure dependence for both samples but slopes are of opposite signs. (12 refs).

  2. Branching of positive discharge streamers in air at varying pressures

    NARCIS (Netherlands)

    Briels, T.M.P.; Veldhuizen, van E.M.; Ebert, U.M.

    2005-01-01

    The formation of positive streamers in a 17-mm gap in air is studied at pressures varying in the range from 1010 to 100 mbar. An intensified charge coupled device camera is used to image the discharge. At high pressures, the discharge shows many branches, while at low pressure, fewer branches arise.

  3. Prospective randomized crossover study of a new closed-loop control system versus pressure support during weaning from mechanical ventilation.

    Science.gov (United States)

    Clavieras, Noémie; Wysocki, Marc; Coisel, Yannael; Galia, Fabrice; Conseil, Matthieu; Chanques, Gerald; Jung, Boris; Arnal, Jean-Michel; Matecki, Stefan; Molinari, Nicolas; Jaber, Samir

    2013-09-01

    Intellivent is a new full closed-loop controlled ventilation that automatically adjusts both ventilation and oxygenation parameters. The authors compared gas exchange and breathing pattern variability of Intellivent and pressure support ventilation (PSV). In a prospective, randomized, single-blind design crossover study, 14 patients were ventilated during the weaning phase, with Intellivent or PSV, for two periods of 24 h in a randomized order. Arterial blood gases were obtained after 1, 8, 16, and 24 h with each mode. Ventilatory parameters were recorded continuously in a breath-by-breath basis during the two study periods. The primary endpoint was oxygenation, estimated by the calculation of the difference between the PaO2/FIO2 ratio obtained after 24 h of ventilation and the PaO2/FIO2 ratio obtained at baseline in each mode. The variability in the ventilatory parameters was also evaluated by the coefficient of variation (SD to mean ratio). There were no adverse events or safety issues requiring premature interruption of both modes. The PaO2/FIO2 (mean ± SD) ratio improved significantly from 245 ± 75 at baseline to 294 ± 123 (P = 0.03) after 24 h of Intellivent. The coefficient of variation of inspiratory pressure and positive end-expiratory pressure (median [interquartile range]) were significantly higher with Intellivent, 16 [11-21] and 15 [7-23]%, compared with 6 [5-7] and 7 [5-10]% in PSV. Inspiratory pressure, positive end-expiratory pressure, and FIO2 changes were adjusted significantly more often with Intellivent compared with PSV. Compared with PSV, Intellivent during a 24-h period improved the PaO2/FIO2 ratio in parallel with more variability in the ventilatory support and more changes in ventilation settings.

  4. The vascular basis of the positional influence of the intraocular pressure.

    Science.gov (United States)

    Krieglstein, G K; Waller, W K; Leydhecker, W

    1978-05-02

    By measuring intraocular pressure in different body positions from 60 degrees semiupright to 30 degrees head down, a nonlinear relationship between IOP increase and body position was confirmed. IOP postural response in individual subjects was roughly correlated to ophthalmic arterial pressure and to the episcleral venous pressure postural response. In one series of subjects, the episcleral venous pressure increments due to posture wa; parallel to the applanation-indentation disparity in the same individual eyes. Differential tonometry with applanation or indentation procedures under blind conditions gave significantly low indentation readings. It is concluded that IOP postural response depends on arterial and venous vascular changes when subjects move from an erect to a horizontal body position. Blood expulsion from the choroid by indentation tonometry might be the reason that this tonometric procedure does not measure IOP changes based on vascular changes.

  5. Evaluation of Peak Expiratory Flow Rates (PEFR) of Workers in a ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    and knowledge of occupational health associated with the ... the respiratory system with significant. 5 ... Peak Expiratory Flow Rates (PEFR) of workers in a cement factory — Douglas K. E, Alasia D. D. ... history of cigarette smoking and chronic.

  6. Continuous positive airway pressure: Physiology and comparison of devices.

    Science.gov (United States)

    Gupta, Samir; Donn, Steven M

    2016-06-01

    Nasal continuous positive airway pressure (CPAP) is increasingly used for respiratory support in preterm babies at birth and after extubation from mechanical ventilation. Various CPAP devices are available for use that can be broadly grouped into continuous flow and variable flow. There are potential physiologic differences between these CPAP systems and the choice of a CPAP device is too often guided by individual expertise and experience rather than by evidence. When interpreting the evidence clinicians should take into account the pressure generation sources, nasal interface, and the factors affecting the delivery of pressure, such as mouth position and respiratory drive. With increasing use of these devices, better monitoring techniques are required to assess the efficacy and early recognition of babies who are failing and in need of escalated support. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Some infant ventilators do not limit peak inspiratory pressure reliably during active expiration.

    Science.gov (United States)

    Kirpalani, H; Santos-Lyn, R; Roberts, R

    1988-09-01

    In order to minimize barotrauma in newborn infants with respiratory failure, peak inspiratory pressures should not exceed those required for adequate gas exchange. We examined whether four commonly used pressure-limited, constant flow ventilators limit pressure reliably during simulated active expiration against the inspiratory stroke of the ventilator. Three machines of each type were tested at 13 different expiratory flow rates (2 to 14 L/min). Flow-dependent pressure overshoot above a dialed pressure limit of 20 cm H2O was observed in all machines. However, the magnitude differed significantly between ventilators from different manufacturers (p = .0009). Pressure overshoot above 20 cm H2O was consistently lowest in the Healthdyne (0.8 cm H2O at 2 L/min, 3.6 cm H2O at 14 L/min) and highest in the Bourns BP200 (3.0 cm H2O at 2 L/min, 15.4 cm H2O at 14 L/min). We conclude that peak inspiratory pressure overshoots on pressure-limited ventilators occur during asynchronous expiration. This shortcoming may contribute to barotrauma in newborn infants who "fight" positive-pressure ventilation.

  8. compliance of the respiratory system as a predictor for successful

    African Journals Online (AJOL)

    clinical, ventilatory and blood gas criteria were studied. ... pressure (PIP) and positive end-expiratory pressure (PEEP) represented ... criteria for extubation, we found that bedside measurement of total ... position in neutral head-neck posture.

  9. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

    Science.gov (United States)

    Prella, Maura; Feihl, François; Domenighetti, Guido

    2002-10-01

    The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration. Prospective, observational study. A multidisciplinary ICU in a nonuniversity, acute-care hospital. Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years). Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones. PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

  10. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    Science.gov (United States)

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  12. Duration of continuous positive airway pressure in premature infants

    OpenAIRE

    Bamat, Nicolas; Jensen, Erik A.; Kirpalani, Haresh

    2016-01-01

    Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy.

  13. Lung volumes and maximal respiratory pressures in collegiate swimmers and runners.

    Science.gov (United States)

    Cordain, L; Tucker, A; Moon, D; Stager, J M

    1990-03-01

    To determine whether respiratory muscle strength is related to pulmonary volume differences in athletes and nonathletes, 11 intercollegiate female swimmers, 11 female cross-country runners, and two nonathletic control groups, matched to the athletes in height and age, were evaluated for pulmonary parameters including maximal inspiratory pressure (PImax) and maximal expiratory pressure (PEmax). Swimmers exhibited larger (p less than .05) vital capacities (VC), residual lung volumes (RV), inspiratory capacities (IC), and functional residual capacities (FRC) than both the runners or the controls but no difference (p greater than .05) in either PImax or inspiratory flow (FIV 25%-75%). Timed expiratory volumes (FEV 0.5 and FEV 1.0) were significantly (p less than .05) lower in the swimmers than in the controls. These data suggest that an adaptational growth may be responsible, in part, for the augmented static lung volumes demonstrated in swimmers.

  14. Cystic Fibrosis: Are Volumetric Ultra-Low-Dose Expiratory CT Scans Sufficient for Monitoring Related Lung Disease?

    DEFF Research Database (Denmark)

    Loeve, Martine; Lequin, Maarten H; Bruijne, Marleen de

    2009-01-01

    Purpose: To assess whether chest computed tomography (CT) scores from ultra-low-dose end-expiratory scans alone could suffice for assessment of all cystic fibrosis (CF)-related structural lung abnormalities. Materials and Methods: In this institutional review board–approved study, 20 patients...... with CF aged 6–20 years (eight males, 12 females) underwent low-dose end-inspiratory CT and ultra-low-dose end-expiratory CT. Informed consent was obtained. Scans were randomized and scored by using the Brody-II CT scoring system to assess bronchiectasis, airway wall thickening, mucus plugging......-Altman plots. Results: Median age was 12.6 years (range, 6.3–20.3 years), median forced expiratory volume in 1 second was 100% (range, 46%–127%) of the predicted value, and median forced vital capacity was 99% (range, 61%–123%) of the predicted value. Very good agreement was observed between end...

  15. Age group classification and gender detection based on forced expiratory spirometry.

    Science.gov (United States)

    Cosgun, Sema; Ozbek, I Yucel

    2015-08-01

    This paper investigates the utility of forced expiratory spirometry (FES) test with efficient machine learning algorithms for the purpose of gender detection and age group classification. The proposed method has three main stages: feature extraction, training of the models and detection. In the first stage, some features are extracted from volume-time curve and expiratory flow-volume loop obtained from FES test. In the second stage, the probabilistic models for each gender and age group are constructed by training Gaussian mixture models (GMMs) and Support vector machine (SVM) algorithm. In the final stage, the gender (or age group) of test subject is estimated by using the trained GMM (or SVM) model. Experiments have been evaluated on a large database from 4571 subjects. The experimental results show that average correct classification rate performance of both GMM and SVM methods based on the FES test is more than 99.3 % and 96.8 % for gender and age group classification, respectively.

  16. Duration of continuous positive airway pressure in premature infants

    Science.gov (United States)

    Bamat, Nicolas; Jensen, Erik A.; Kirpalani, Haresh

    2016-01-01

    SUMMARY Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy. PMID:26948885

  17. High blood pressure, antihypertensive medication and lung function in a general adult population

    Science.gov (United States)

    2011-01-01

    Background Several studies showed that blood pressure and lung function are associated. Additionally, a potential effect of antihypertensive medication, especially beta-blockers, on lung function has been discussed. However, side effects of beta-blockers have been investigated mainly in patients with already reduced lung function. Thus, aim of this analysis is to determine whether hypertension and antihypertensive medication have an adverse effect on lung function in a general adult population. Methods Within the population-based KORA F4 study 1319 adults aged 40-65 years performed lung function tests and blood pressure measurements. Additionally, information on anthropometric measurements, medical history and use of antihypertensive medication was available. Multivariable regression models were applied to study the association between blood pressure, antihypertensive medication and lung function. Results High blood pressure as well as antihypertensive medication were associated with lower forced expiratory volume in one second (p = 0.02 respectively p = 0.05; R2: 0.65) and forced vital capacity values (p = 0.01 respectively p = 0.05, R2: 0.73). Furthermore, a detailed analysis of antihypertensive medication pointed out that only the use of beta-blockers was associated with reduced lung function, whereas other antihypertensive medication had no effect on lung function. The adverse effect of beta-blockers was significant for forced vital capacity (p = 0.04; R2: 0.65), while the association with forced expiratory volume in one second showed a trend toward significance (p = 0.07; R2: 0.73). In the same model high blood pressure was associated with reduced forced vital capacity (p = 0.01) and forced expiratory volume in one second (p = 0.03) values, too. Conclusion Our analysis indicates that both high blood pressure and the use of beta-blockers, but not the use of other antihypertensive medication, are associated with reduced lung function in a general adult

  18. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  19. First characterization of the expiratory flow increase technique: method development and results analysis

    International Nuclear Information System (INIS)

    Maréchal, L; Barthod, C; Jeulin, J C

    2009-01-01

    This study provides an important contribution to the definition of the expiratory flow increase technique (EFIT). So far, no measuring means were suited to assess the manual EFIT performed on infants. The proposed method aims at objectively defining the EFIT based on the quantification of pertinent cognitive parameters used by physiotherapists when practicing. We designed and realized customized instrumented gloves endowed with pressure and displacement sensors, and the associated electronics and software. This new system is specific to the manoeuvre, to the user and innocuous for the patient. Data were collected and analysed on infants with bronchiolitis managed by an expert physiotherapist. The analysis presented is realized on a group of seven subjects (mean age: 6.1 months, SD: 1.1; mean chest circumference: 44.8 cm, SD: 1.9). The results are consistent with the physiotherapist's tactility. In spite of inevitable variability due to measurements on infants, repeatable quantitative data could be reported regarding the manoeuvre characteristics: the magnitudes of displacements do not exceed 10 mm on both hands; the movement of the thoracic hand is more vertical than the movement of the abdominal hand; the maximum applied pressure with the thoracic hand is about twice higher than with the abdominal hand; the thrust of the manual compression lasts (590 ± 62) ms. Inter-operators measurements are in progress in order to generalize these results

  20. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  1. Optimum position for wells producing at constant wellbore pressure

    Energy Technology Data Exchange (ETDEWEB)

    Camacho-Velazquez, R.; Rodriguez de la Garza, F. [Univ. Nacional Autonoma de Mexico, Mexico City (Mexico); Galindo-Nava, A. [Inst. Mexicanos del Petroleo, Mexico City (Mexico)]|[Univ. Nacional de Mexico, Mexico City (Mexico); Prats, M.

    1994-12-31

    This paper deals with the determination of the optimum position of several wells, producing at constant different wellbore pressures from a two-dimensional closed-boundary reservoirs, to maximize the cumulative production or the total flow rate. To achieve this objective they authors use an improved version of the analytical solution recently proposed by Rodriguez and Cinco-Ley and an optimization algorithm based on a quasi-Newton procedure with line search. At each iteration the algorithm approximates the negative of the objective function by a cuadratic relation derived from a Taylor series. The improvement of rodriguez and Cinco`s solution is attained in four ways. First, an approximation is obtained, which works better at earlier times (before the boundary dominated period starts) than the previous solution. Second, the infinite sums that are present in the solution are expressed in a condensed form, which is relevant for reducing the computer time when the optimization algorithm is used. Third, the solution is modified to take into account the possibility of having wells starting to produce at different times. This point allows them to deal with the problem of getting the optimum position for an infill drilling program. Last, the solution is extended to include the possibility of changing the value of wellbore pressure or being able to stimulate any of the wells at any time. When the wells are producing at different wellbore pressures it is found that the optimum position is a function of time, otherwise the optimum position is fixed.

  2. THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY

    Science.gov (United States)

    THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY. William F. McDonnell Human Studies Division, NHEERL, U.S. Environmental Protection Agency, RTP, NC 27711. Short-term exposure to ozone results in a neurally-mediated decrease in the ab...

  3. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  4. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation

    International Nuclear Information System (INIS)

    Schranz, C; Möller, K; Becher, T; Schädler, D; Weiler, N

    2014-01-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (p I ), inspiration and expiration time (t I , t E ) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal p I and adequate t E can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's ‘optimized’ settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end-expiratory

  5. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation.

    Science.gov (United States)

    Schranz, C; Becher, T; Schädler, D; Weiler, N; Möller, K

    2014-03-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (pI), inspiration and expiration time (tI, tE) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal pI and adequate tE can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's 'optimized' settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end-expiratory pressure.

  6. A study of diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India

    Directory of Open Access Journals (Sweden)

    Jenny Jayapal

    2014-01-01

    Full Text Available Background: Peak Expiratory Flow Rate (PEFR reflects the strength and condition of respiratory muscles and the degree of airflow limitation in large airways. PEFR shows hour to hour variation that follows a specific pattern in asthmatics and healthy individuals. Adequate data is not available for the diurnal variation in normal individuals who are students in professional courses and had a sedentary life style. Hence, this study was undertaken to study the diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India. Materials and Methods: Peak expiratory flow rate was recorded in 50 adult healthy female students aged 18-23 years and studying in professional courses. Mini Wright′s peak flow meter was used to measure the peak expiratory flow rate. PEFR were recorded at 7-8 a.m., 10-11 a.m., 1-2 p.m., 4-5 p.m., and 7-8 p.m. for two consecutive days. Results: On analysis of PEFR records of individual subjects, it was seen that there was an overall dip in the morning at 7-8 h PEFR, which increased in the daytime, peaking in the afternoon at 1-2 p.m. and eventually decreased in the night. Subjects did not show the peak PEFR values at the same time point, 10% of subjects had a rise in PEFR in the early morning, afternoon (1-2 p.m. peak was observed in 48% subjects and evening (4-5 p.m. peak was observed in 16% subjects. 14% subjects showed a peak in the night time (7-8 p.m. PEFR values. Conclusion: This study provided the preliminary reference data of diurnal variation of peak expiratory flow rate in healthy adults. Since, there is a variation in the peak expiratory flow rate recorded during different time points of the day; hence, to compare the PEFR between individuals it is advisable to record the PEFR at the same time point.

  7. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  8. Physiological and morphological determinants of maximal expiratory flow in chronic obstructive lung disease

    NARCIS (Netherlands)

    H.A.W.M. Tiddens (Harm); J.M. Bogaard (Jan); J.C. de Jongste (Johan); W.C.J. Hop (Wim); H.O. Coxson (Harvey); P.D. Pare

    1996-01-01

    textabstractMaximal expiratory flow in chronic obstructive pulmonary disease (COPD) could be reduced by three different mechanisms; loss of lung elastic recoil, decreased airway conductance upstream of flow-limiting segments; and increased collapsibility of airways.

  9. Effect of upper body position on arterial stiffness: influence of hydrostatic pressure and autonomic function.

    Science.gov (United States)

    Schroeder, Elizabeth C; Rosenberg, Alexander J; Hilgenkamp, Thessa I M; White, Daniel W; Baynard, Tracy; Fernhall, Bo

    2017-12-01

    To evaluate changes in arterial stiffness with positional change and whether the stiffness changes are due to hydrostatic pressure alone or if physiological changes in vasoconstriction of the conduit arteries play a role in the modulation of arterial stiffness. Thirty participants' (male = 15, 24 ± 4 years) upper bodies were positioned at 0, 45, and 72° angles. Pulse wave velocity (PWV), cardio-ankle vascular index, carotid beta-stiffness index, carotid blood pressure (cBP), and carotid diameters were measured at each position. A gravitational height correction was determined using the vertical fluid column distance (mmHg) between the heart and carotid artery. Carotid beta-stiffness was calibrated using three methods: nonheight corrected cBP of each position, height corrected cBP of each position, and height corrected cBP of the supine position (theoretical model). Low frequency systolic blood pressure variability (LFSAP) was analyzed as a marker of sympathetic activity. PWV and cardio-ankle vascular index increased with position (P hydrostatic pressure. Arterial stiffness indices based on Method 2 were not different from Method 3 (P = 0.65). LFSAP increased in more upright positions (P pressure did not (P > 0.05). Arterial stiffness increases with a more upright body position. Carotid beta-stiffness needs to be calibrated accounting for hydrostatic effects of gravity if measured in a seated position. It is unclear why PWV increased as this increase was independent of blood pressure. No difference between Methods 2 and 3 presumably indicates that the beta-stiffness increases are only pressure dependent, despite the increase in vascular sympathetic modulation.

  10. Nasal continuous positive airway pressure

    DEFF Research Database (Denmark)

    Scholze, Alexandra; Lamwers, Stephanie; Tepel, Martin

    2012-01-01

    Obstructive sleep apnoea (OSA) is linked to increased cardiovascular risk. This risk can be reduced by nasal continuous positive airway pressure (nCPAP) treatment. As OSA is associated with an increase of several vasoconstrictive factors, we investigated whether nCPAP influences the digital volume...... pulse wave. We performed digital photoplethysmography during sleep at night in 94 consecutive patients who underwent polysomnography and 29 patients treated with nCPAP. Digital volume pulse waves were obtained independently of an investigator and were quantified using an algorithm for continuous.......01; n = 94) and the arousal index (Spearman correlation, r = 0.21; p CPAP treatment, the AHI was significantly reduced from 27 ± 3 events · h(-1) to 4 ± 2 events · h(-1) (each n = 29; p

  11. Static respiratory muscle work during immersion with positive and negative respiratory loading.

    Science.gov (United States)

    Taylor, N A; Morrison, J B

    1999-10-01

    Upright immersion imposes a pressure imbalance across the thorax. This study examined the effects of air-delivery pressure on inspiratory muscle work during upright immersion. Eight subjects performed respiratory pressure-volume relaxation maneuvers while seated in air (control) and during immersion. Hydrostatic, respiratory elastic (lung and chest wall), and resultant static respiratory muscle work components were computed. During immersion, the effects of four air-delivery pressures were evaluated: mouth pressure (uncompensated); the pressure at the lung centroid (PL,c); and at PL,c +/-0.98 kPa. When breathing at pressures less than the PL,c, subjects generally defended an expiratory reserve volume (ERV) greater than the immersed relaxation volume, minus residual volume, resulting in additional inspiratory muscle work. The resultant static inspiratory muscle work, computed over a 1-liter tidal volume above the ERV, increased from 0.23 J. l(-1), when subjects were breathing at PL,c, to 0.83 J. l(-1) at PL,c -0.98 kPa (P work was minimal. When breathing at PL,c +0.98 kPa, subjects adopted an ERV less than the immersed relaxation volume, minus residual volume, resulting in 0.36 J. l(-1) of expiratory muscle work. Thus static inspiratory muscle work varied with respiratory loading, whereas PL,c air supply minimized this work during upright immersion, restoring lung-tissue, chest-wall, and static muscle work to levels obtained in the control state.

  12. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    Science.gov (United States)

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  13. High-Frequency Chest Compression: A Summary of the Literature

    Directory of Open Access Journals (Sweden)

    Cara F Dosman

    2005-01-01

    Full Text Available The purpose of the present literature summary is to describe high-frequency chest compression (HFCC, summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have shown that HFCC leads to more mucus clearance and better lung function compared with conventional chest physiotherapy. However, HFCC also decreases end-expiratory lung volume, which can lead to increased airway resistance and a decreased oscillated volume. Adding positive end-expiratory pressure to HFCC has been shown to prevent this decrease in end-expiratory lung volume and to increase the oscillated volume. It is possible that the HFCC-induced decrease in end-expiratory lung volume may result in more mucus clearance in airways that remain open by reducing airway size. Adjunctive methods, such as positive end-expiratory pressure, may not always be needed to make HFCC more effective.

  14. Non-invasive positive pressure ventilation for acute asthma in children

    DEFF Research Database (Denmark)

    Korang, Steven Kwasi; Feinberg, Joshua; Wetterslev, Jørn

    2016-01-01

    (age independently screened titles and abstracts. We retrieved all relevant full-text study reports, independently screened the full text, identified trials for inclusion and identified and recorded...... reasons for exclusion of ineligible trials. We resolved disagreements through discussion or, if required, consulted a third review author. We recorded the selection process in sufficient detail to complete a PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) flow diagram...... both studies as having high risk of bias; both trials assessed effects of bilateral positive airway pressure (BiPAP). Neither trial used continuous positive airway pressure (CPAP). Controls received standard care. Investigators reported no deaths and no serious adverse events (Grades of Recommendation...

  15. Variable pattern contamination control under positive pressure

    International Nuclear Information System (INIS)

    Philippi, H.M.

    1997-01-01

    Airborne contamination control in nuclear and biological laboratories is traditionally achieved by directing the space ventilation air at subatmospheric pressures in one fixed flow pattern. However, biological and nuclear contamination flow control in the new Biological Research Facility, to be commissioned at the Chalk River Laboratories in 1996, will have the flexibility to institute a number of contamination control patterns, all achieved at positive (above atmospheric) pressures. This flexibility feature, made possible by means of a digitally controlled ventilation system, changes the facility ventilation system from being a relatively rigid building service operated by plant personnel into a flexible building service which can be operated by the facility research personnel. This paper focuses on and describes the application of these unique contamination control features in the design of the new Biological Research Facility. 3 refs., 7 figs

  16. Variable pattern contamination control under positive pressure

    Energy Technology Data Exchange (ETDEWEB)

    Philippi, H.M. [Chalk River Labs., Ontario (Canada)

    1997-08-01

    Airborne contamination control in nuclear and biological laboratories is traditionally achieved by directing the space ventilation air at subatmospheric pressures in one fixed flow pattern. However, biological and nuclear contamination flow control in the new Biological Research Facility, to be commissioned at the Chalk River Laboratories in 1996, will have the flexibility to institute a number of contamination control patterns, all achieved at positive (above atmospheric) pressures. This flexibility feature, made possible by means of a digitally controlled ventilation system, changes the facility ventilation system from being a relatively rigid building service operated by plant personnel into a flexible building service which can be operated by the facility research personnel. This paper focuses on and describes the application of these unique contamination control features in the design of the new Biological Research Facility. 3 refs., 7 figs.

  17. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Meijer, G. G.; Postma, D. S.; van der Heide, S.; de Reus, D. M.; Roorda, R. J.; Koëter, G. H.; van Aalderen, W. M.

    1996-01-01

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  18. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Postma, DS; VanderHeide, S; DeReus, DM; Koeter, GH; VanAalderen, WMC; Meijer, G.

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  19. Insomnia complaints in lean patients with obstructive sleep apnea negatively affect positive airway pressure treatment adherence.

    Science.gov (United States)

    Eysteinsdottir, Bjorg; Gislason, Thorarinn; Pack, Allan I; Benediktsdottir, Bryndís; Arnardottir, Erna S; Kuna, Samuel T; Björnsdottir, Erla

    2017-04-01

    The objective of this study was to evaluate the determinants of long-term adherence to positive airway pressure treatment among patients with obstructive sleep apnea, with special emphasis on patients who stop positive airway pressure treatment within 1 year. This is a prospective long-term follow-up of subjects in the Icelandic Sleep Apnea Cohort who were diagnosed with obstructive sleep apnea between 2005 and 2009, and started on positive airway pressure treatment. In October 2014, positive airway pressure adherence was obtained by systematically evaluating available clinical files (n = 796; 644 males, 152 females) with moderate to severe obstructive sleep apnea (apnea-hypopnea index ≥15 events per h). The mean follow-up time was 6.7 ± 1.2 years. In total, 123 subjects (15.5%) returned their positive airway pressure device within the first year, 170 (21.4%) returned it later and 503 (63.2%) were still using positive airway pressure. The quitters within the first year had lower body mass index, milder obstructive sleep apnea, less sleepiness, and more often had symptoms of initial and late insomnia compared with long-term positive airway pressure users at baseline. Both initial and late insomnia were after adjustment still significantly associated with being an early quitter among subjects with body mass index insomnia are associated with early quitting on positive airway pressure among non-obese subjects. © 2016 European Sleep Research Society.

  20. [A project to reduce the incidence of facial pressure ulcers caused by prolonged surgery with prone positioning].

    Science.gov (United States)

    Lee, Wen-Yi; Lin, Pao-Chen; Weng, Chia-Hsing; Lin, Yi-Lin; Tsai, Wen-Lin

    2012-06-01

    We observed in our institute a 13.6% incidence of prolonged surgery (>4 hours) induced facial pressure ulcers that required prone positioning. Causes identified included: (1) customized silicon face pillows used were not suited for every patient; (2) our institute lacked a standard operating procedure for prone positioning; (3) our institute lacked a postoperative evaluation and audit procedure for facial pressure ulcers. We designed a strategy to reduce post-prolonged surgery facial pressure ulcer incidence requiring prone positioning by 50% (i.e., from 13.6% to 6.8%). We implemented the following: (1) Created a new water pillow to relieve facial pressure; (2) Implemented continuing education pressure ulcer prevention and evaluation; (3) Established protocols on standard care for prone-position patients and proper facial pressure ulcer identification; (4) Established a face pressure ulcers accident reporting mechanism; and (5) Established an audit mechanism facial pressure ulcer cases. After implementing the resolution measures, 116 patients underwent prolonged surgery in a prone position (mean operating time: 298 mins). None suffered from facial pressure ulcers. The measures effectively reduced the incidence of facial pressure ulcers from 13.6% to 0.0%. The project used a water pillow to relieve facial pressure and educated staff to recognize and evaluate pressure ulcers. These measures were demonstrated effective in reducing the incidence of facial pressure ulcers caused by prolonged prone positioning.

  1. Effects of continuous positive airway pressure on neurocognitive function in obstructive sleep apnea patients: The Apnea Positive Pressure Long-term Efficacy Study (APPLES).

    Science.gov (United States)

    Kushida, Clete A; Nichols, Deborah A; Holmes, Tyson H; Quan, Stuart F; Walsh, James K; Gottlieb, Daniel J; Simon, Richard D; Guilleminault, Christian; White, David P; Goodwin, James L; Schweitzer, Paula K; Leary, Eileen B; Hyde, Pamela R; Hirshkowitz, Max; Green, Sylvan; McEvoy, Linda K; Chan, Cynthia; Gevins, Alan; Kay, Gary G; Bloch, Daniel A; Crabtree, Tami; Dement, William C

    2012-12-01

    To determine the neurocognitive effects of continuous positive airway pressure (CPAP) therapy on patients with obstructive sleep apnea (OSA). The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blind, 2-arm, sham-controlled, multicenter trial conducted at 5 U.S. university, hospital, or private practices. Of 1,516 participants enrolled, 1,105 were randomized, and 1,098 participants diagnosed with OSA contributed to the analysis of the primary outcome measures. Active or sham CPAP MEASUREMENTS: THREE NEUROCOGNITIVE VARIABLES, EACH REPRESENTING A NEUROCOGNITIVE DOMAIN: Pathfinder Number Test-Total Time (attention and psychomotor function [A/P]), Buschke Selective Reminding Test-Sum Recall (learning and memory [L/M]), and Sustained Working Memory Test-Overall Mid-Day Score (executive and frontal-lobe function [E/F]) The primary neurocognitive analyses showed a difference between groups for only the E/F variable at the 2 month CPAP visit, but no difference at the 6 month CPAP visit or for the A/P or L/M variables at either the 2 or 6 month visits. When stratified by measures of OSA severity (AHI or oxygen saturation parameters), the primary E/F variable and one secondary E/F neurocognitive variable revealed transient differences between study arms for those with the most severe OSA. Participants in the active CPAP group had a significantly greater ability to remain awake whether measured subjectively by the Epworth Sleepiness Scale or objectively by the maintenance of wakefulness test. CPAP treatment improved both subjectively and objectively measured sleepiness, especially in individuals with severe OSA (AHI > 30). CPAP use resulted in mild, transient improvement in the most sensitive measures of executive and frontal-lobe function for those with severe disease, which suggests the existence of a complex OSA-neurocognitive relationship. Registered at clinicaltrials.gov. Identifier: NCT00051363. Kushida CA; Nichols DA; Holmes

  2. Dead space and slope indices from the expiratory carbon dioxide tension-volume curve

    NARCIS (Netherlands)

    A.H. Kars (Alice); J.M. Bogaard (Jan); Th. Stijnen (Theo); J. de Vries; A.F.M. Verbraak (Anton); C. Hilvering

    1997-01-01

    textabstractThe slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate

  3. Bi-level positive airway pressure ventilation for treating heart failure with central sleep apnea that is unresponsive to continuous positive airway pressure.

    Science.gov (United States)

    Dohi, Tomotaka; Kasai, Takatoshi; Narui, Koji; Ishiwata, Sugao; Ohno, Minoru; Yamaguchi, Tetsu; Momomura, Shin-Ichi

    2008-07-01

    Cheyne-Stokes respiration with central sleep apnea (CSR-CSA) is associated with a poor prognosis in patients with heart failure (HF). However, some patients do not respond to continuous positive airway pressure (CPAP), so other therapeutic modalities should be considered, such as bi-level positive airway pressure (PAP), which also assists respiration and might be effective for such patients. The 20 patients with HF because of left ventricular systolic dysfunction were assessed: 8 had ischemic etiology, and all had severe CSA according to the apnea - hypopnea index (AHI) determined by polysomnography. All diagnosed patients underwent repeat polysomnography using CPAP. The AHI improved significantly in 11 (AHI or=15). Bi-level PAP titration significantly improved the AHI in the latter group. Those who were unresponsive to CPAP had significantly lower PaCO(2), higher plasma brain natriuretic peptide (BNP), longer mean duration of CSR and fewer obstructive episodes than CPAP responders. After 6 months of positive airway support with either CPAP (n=9) or bi-level PAP (n=7), BNP levels significantly decreased and left ventricular ejection fraction significantly increased. Bi-level PAP could be an effective alternative for patients with HF and pure CSR-CSA who are unresponsive to CPAP.

  4. Backrest position in prevention of pressure ulcers and ventilator-associated pneumonia: conflicting recommendations.

    Science.gov (United States)

    Burk, Ruth Srednicki; Grap, Mary Jo

    2012-01-01

    Pressure ulcers and ventilator-associated pneumonia (VAP) are both common in acute and critical care settings and are considerable sources of morbidity, mortality, and health care costs. To prevent pressure ulcers, guidelines limit bed backrest elevation to less than 30 degrees, whereas recommendations to reduce VAP include use of backrest elevations of 30 degrees or more. Although a variety of risk factors beyond patient position have been identified for both pressure ulcers and VAP, this article will focus on summarizing the major evidence for each of these apparently conflicting positioning strategies and discuss implications for practice in managing mechanically ventilated patients with risk factors for both pressure ulcers and VAP. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. An indigenous economic technique of positive pressure retrograde urethrography in female patients

    Directory of Open Access Journals (Sweden)

    H Singh

    2001-01-01

    Full Text Available Usually double balloon catheter is required forpositive pressure retrograde urethrography in females. We describe a technique of positive pressure retrograde urethrography using Foley catheter and rubber stopper, inexpensive and could be adopted in any hospital or radiological suite.

  6. [Preventing Facial Pressure Injuries in Patients Who Use Noninvasive Positive Pressure Ventilators: The Efficiency of Dressings].

    Science.gov (United States)

    Tai, Chia-Hua; Hsu, Mei-Yu

    2016-10-01

    Noninvasive positive pressure ventilation (NPPV) provides ventilation without tracheal intubation. Facial pressure injury is a recognized complication of this technique, making the prevention of facial pressure injuries an important issue for NPPV patients. The present study compared the effects of foam dressing and hydrocolloid dressing in preventing facial pressure injuries in NPPV patients. A randomized clinical trial was used to evaluate participants that were referred from the intensive care unit of a medical center in eastern Taiwan. Participants were randomized into two groups: the foam dressing group and the hydrocolloid dressing group. Statistics used in analysis were: analysis mean, standard deviation, chi-square, independent t-test, and the generalized estimating equation. Sixty participants were enrolled as participants. The incidence rate of facial pressure injury was 11.7% (7/60). No significant difference was found between the two groups in terms of duration of NPPV use, incidence of facial pressure injury, and occurrence time of facial pressure injury. However, the hydrocolloid dressing group had a higher usage amount than the foam dressing group (p < .05). Foam and hydrocolloid dressings are both helpful in preventing facial pressure injury when used in conjunction with regular skin assessments.

  7. Peak expiratory flow variability, bronchial responsiveness, and susceptibility to ambient air pollution in adults

    NARCIS (Netherlands)

    Boezen, M; Schouten, Jan; Rijcken, B; Vonk, J; Gerritsen, J; Hoek, G; Brunekreef, B; Postma, D

    1998-01-01

    Bronchial hyperresponsiveness (BHR) and peak expiratory flow (PEF) variability are associated expressions of airway lability, yet probably reflect different underlying pathophysiologic mechanisms. We investigated whether both measures can be used interchangeably to identify subjects who are

  8. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    Science.gov (United States)

    Beda, Alessandro; Güldner, Andreas; Carvalho, Alysson R; Zin, Walter Araujo; Carvalho, Nadja C; Huhle, Robert; Giannella-Neto, Antonio; Koch, Thea; de Abreu, Marcelo Gama

    2014-01-01

    Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  9. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    Directory of Open Access Journals (Sweden)

    Alessandro Beda

    Full Text Available BACKGROUND: Measuring esophageal pressure (Pes using an air-filled balloon catheter (BC is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC, during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. MAIN RESULTS: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal than in AFC and LFC (<3%. Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. CONCLUSIONS: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  10. Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System

    Science.gov (United States)

    Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren

    2017-11-01

    The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.

  11. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

    Directory of Open Access Journals (Sweden)

    Johnson KG

    2015-10-01

    Full Text Available Karin Gardner Johnson, Douglas Clark Johnson Department of Medicine, Baystate Medical Center, Springfield, MA, USA Abstract: Many types of positive airway pressure (PAP devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features. Keywords: BiPAP, CPAP, iVAPS, AVAPS, ASV, positive pressure respiration, instrumentation, treatment algorithm

  12. Association between temporal mean arterial pressure and brachial noninvasive blood pressure during shoulder surgery in the beach chair position during general anesthesia.

    Science.gov (United States)

    Triplet, Jacob J; Lonetta, Christopher M; Everding, Nathan G; Moor, Molly A; Levy, Jonathan C

    2015-01-01

    Estimation of cerebral perfusion pressure during elective shoulder surgery in the beach chair position is regularly performed by noninvasive brachial blood pressure (NIBP) measurements. The relationship between brachial mean arterial pressure and estimated temporal mean arterial pressure (eTMAP) is not well established and may vary with patient positioning. Establishing a ratio between eTMAP and NIBP at varying positions may provide a more accurate estimation of cerebral perfusion using noninvasive measurements. This prospective study included 57 patients undergoing elective shoulder surgery in the beach chair position. All patients received an interscalene block and general anesthesia. After the induction of general anesthesia, values for eTMAP and NIBP were recorded at 0°, 30°, and 70° of incline. A statistically significant, strong, and direct correlation between NIBP and eTMAP was found at 0° (r = 0.909, P ≤ .001), 30° (r = 0.874, P Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Seasonal variations in house dust mite influence the circadian peak expiratory flow amplitude

    NARCIS (Netherlands)

    Postma, DS; vanderHeide, S; deReus, DM; Koeter, GH; vanAalderen, WMC; Meijer, G.

    1996-01-01

    The aim of the study was to investigate whether seasonal differences in house dust mite (HDM) allergen exposure influence the circadian peak expiratory flow (PEF) amplitude in asthmatic children. Asthmatic children (n = 25) with a solitary allergy to HDM were studied in spring and in autumn. All

  14. Dynamic airway pressure-time curve profile (Stress Index): a systematic review.

    Science.gov (United States)

    Terragni, Pierpaolo; Bussone, Guido; Mascia, Luciana

    2016-01-01

    The assessment of respiratory mechanics at the bedside is necessary in order to identify the most protective ventilatory strategy. Indeed in the last 20 years, adverse effects of positive ventilation to the lung structures have led to a reappraisal of the objectives of mechanical ventilation. The ventilator setting requires repeated readjustment over the period of mechanical ventilation dependency and careful respiratory monitoring to minimize the risks, preventing further injury and permitting the lung and airways healing. Among the different methods that have been proposed and validated, the analysis of dynamic P-t curve (named Stress Index, SI) represents an adequate tool available at the bedside, repeatable and, therefore, able to identify the amount of overdistension occurring in the daily clinical practice, when modifying positive end-expiratory pressure. In this review we will analyze the evidence that supports respiratory mechanics assessment at the bedside and the application of the dynamic P/t curve profile (SI) to optimize protective ventilation in patients with acute respiratory failure.

  15. Reverse Trendelenburg position is a safer technique for lowering central venous pressure without decreasing blood pressure than clamping of the inferior vena cava below the liver.

    Science.gov (United States)

    Yoneda, Godai; Katagiri, Satoshi; Yamamoto, Masakazu

    2015-06-01

    Bleeding remains an important intraoperative complication in patients who undergo hepatectomy. It is generally believed that a reduction in central venous pressure will decrease bleeding from the hepatic venous system. To our knowledge, however, no study has compared the effectiveness of these techniques for controlling bleeding. So we compared the effectiveness of central venous pressure control techniques, such as infrahepatic inferior vena cava clamping, changes in surgical position of the patient, and hypoventilation anesthesia, for lowering central venous pressure. The study group comprised 50 patients who underwent hepatectomy in our department from 2012 through 2013. A central venous catheter was inserted into the right internal jugular vein, and the tip was placed in the superior vena cava. A transducer was placed along the mid-axillary line of the left side of the chest. After opening the abdomen, changes in central venous pressure were measured during inferior vena cava clamping, the reverse Trendelenburg position, the Trendelenburg position, and hypoventilation anesthesia. The inclination relative to the transducer, as measured with an inclinometer, was -10 degrees for the Trendelenburg position and +10 degrees for the reverse Trendelenburg position. The tidal volume was set at 10 mL/kg during conventional anesthesia and 5 mL/kg during hypoventilation anesthesia. The mean central venous pressure was 8.0 cm H(2)O in the supine position during conventional anesthesia, 5.0 cm H(2)O during inferior vena cava clamping, 5.6 cm H(2)O during reverse Trendelenburg position, 10.6 cm H(2)O during Trendelenburg position, and 7.6 cm H(2)O during hypoventilation anesthesia. The mean central venous pressure during inferior vena cava clamping and reverse Trendelenburg position was significantly lower than that during supine position (P = 0.0017 and P = 0.0231, respectively). The mean central venous pressure during hypoventilation

  16. Nasal bi-level positive airway pressure (BiPAP) versus nasal continuous positive airway pressure (CPAP) in preterm infants ≤32 weeks: A retrospective cohort study.

    Science.gov (United States)

    Rong, Zhi-Hui; Li, Wen-Bin; Liu, Wei; Cai, Bao-Huan; Wang, Jing; Yang, Min; Li, Wei; Chang, Li-Wen

    2016-05-01

    To investigate whether Bi-level positive airway pressure (BiPAP), compared with nasal continuous positive airway pressure (CPAP), is a more effective therapeutic strategy in preterm infants ≤32 weeks. All inborn infants between 26(+1) and 32(+6) weeks' gestation, admitted to the neonatal intensive care unit (NICU ) of Tongji Medical Hospital between 1 January, 2010 and 31 December, 2011 (the 2010-2011 cohort or CPAP cohort) and between 1 January, 2012 and 31 December, 2013 (the 2012-2013 cohort or BiPAP cohort), were retrospectively identified. The primary outcome was intubation in infants CPAP were subsequently intubated (P CPAP, reduced the need for intubation within the first 72 h of age. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  17. Comparison of three continuous positive airway pressure (CPAP) interfaces in healthy Beagle dogs during medetomidine-propofol constant rate infusions.

    Science.gov (United States)

    Meira, Carolina; Joerger, Fabiola B; Kutter, Annette P N; Waldmann, Andreas; Ringer, Simone K; Böehm, Stephan H; Iff, Samuel; Mosing, Martina

    2018-03-01

    To compare the efficacy of three continuous positive airway pressure (CPAP) interfaces in dogs on gas exchange, lung volumes, amount of leak during CPAP and rebreathing in case of equipment failure or disconnection. Randomized, prospective, crossover, experimental trial. Ten purpose-bred Beagle dogs. Dogs were in dorsal recumbency during medetomidine-propofol constant rate infusions, breathing room air. Three interfaces were tested in each dog in a consecutive random order: custom-made mask (M), conical face mask (FM) and helmet (H). End-expiratory lung impedance (EELI) measured by electrical impedance tomography was assessed with no interface (baseline), with the interface only (No-CPAP for 3 minutes) and at 15 minutes of 7 cmH 2 O CPAP (CPAP-delivery). PaO 2 was assessed at No-CPAP and CPAP-delivery, partial pressure of inspired carbon dioxide (PICO 2 ; rebreathing assessment) at No-CPAP and the interface leak (ΔP leak ) at CPAP-delivery. Mixed-effects linear regression models were used for statistical analysis (pCPAP-delivery, all interfaces increased EELI by 7% (pCPAP, less rebreathing occurred with M (0.5 kPa, 4 mmHg) than with FM (1.8 kPa, 14 mmHg) and with H (1.4 kPa, 11 mmHg), but also lower PaO 2 was measured with M (9.3 kPa, 70 mmHg) than with H (11.9 kPa, 90 mmHg) and FM (10.8 kPa, 81 mmHg). All three interfaces can be used to provide adequate CPAP in dogs. The leak during CPAP-delivery and the risk of rebreathing and hypoxaemia, when CPAP is not maintained, can be significant. Therefore, animals should always be supervised during administration of CPAP with any of the three interfaces. The performance of the custom-made M was not superior to the other interfaces. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  18. The effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents.

    Science.gov (United States)

    Källman, Ulrika; Engström, Maria; Bergstrand, Sara; Ek, Anna-Christina; Fredrikson, Mats; Lindberg, Lars-Göran; Lindgren, Margareta

    2015-03-01

    Although repositioning is considered an important intervention to prevent pressure ulcers, tissue response during loading in different lying positions has not been adequately explored. To compare the effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents. From May 2011 to August 2012, interface pressure, skin temperature, and blood flow at three tissue depths were measured for 1 hr over the sacrum in 30° supine tilt and 0° supine positions and over the trochanter major in 30° lateral and 90° lateral positions in 25 residents aged 65 years or older. Measurement of interface pressure was accomplished using a pneumatic pressure transmitter connected to a digital manometer, skin temperature using a temperature sensor, and blood flow using photoplethysmography and laser Doppler flowmetry. Interface pressure was significantly higher in the 0° supine and 90° lateral positions than in 30° supine tilt and 30° lateral positions. The mean skin temperature increased from baseline in all positions. Blood flow was significantly higher in the 30° supine tilt position compared to the other positions. A hyperemic response in the post pressure period was seen at almost all tissue depths and positions. The 30° supine tilt position generated less interface pressure and allowed greater tissue perfusion, suggesting that this position is the most beneficial. © The Author(s) 2014.

  19. A switched energy saving position controller for variable-pressure electro-hydraulic servo systems.

    Science.gov (United States)

    Tivay, Ali; Zareinejad, Mohammad; Rezaei, S Mehdi; Baghestan, Keivan

    2014-07-01

    The electro-hydraulic servo system (EHSS) demonstrates a relatively low level of efficiency compared to other available actuation methods. The objective of this paper is to increase this efficiency by introducing a variable supply pressure into the system and controlling this pressure during the task of position tracking. For this purpose, an EHSS structure with controllable supply pressure is proposed and its dynamic model is derived from the basic laws of physics. A switching control structure is then proposed to control both the supply pressure and the cylinder position at the same time, in a way that reduces the overall energy consumption of the system. The stability of the proposed switching control system is guaranteed by proof, and its performance is verified by experimental testing. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Efeitos de diferentes volumes correntes e da pressão expiratória final positiva sobre a troca gasosa na fístula broncopleural experimental Effects of different tidal volumes and positive end expiratory pressure on gas exchange in experimental bronchopleural fistula

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Cavicchia Toneloto

    2008-09-01

    melhora e o débito da fístula é reduzido quando comparado ao volume corrente de 10ml/Kg. Um baixo volume resulta em hipercapnia e grave dessaturação. Finalmente, em qualquer volume corrente, PEEP aumenta o débito da fístula e diminui a ventilação alveolar.OBJECTIVES: The present study was designed to identify the effect of positive end expiratory pressure (PEEP and the ideal pulmonary tidal volume to ventilate animals with a surgically produced bronchopleural fistula, aiming to reduce fistula output without affecting gas exchange. METHODS: Hemodynamic and respiratory assessment of gas exchange was obtained in five, healthy, young, mechanically ventilated Large White pigs under volume controlled ventilation with FiO2 of 0.4 and an inspiration:expiration ratio of 1:2, keeping respiratory rate at 22 cpm. A bronchopleural fistula was produced by resection of the lingula. Underwater seal drainage was installed and the thorax was hermetically closed. Gas exchange and fistula output were measured with the animals ventilated sequentially with tidal volumes of 4 ml/kg, 7 ml/kg and 10 ml/Kg alternating zero of positive end expiratory pressure (ZEEP and PEEP of 10 cmH2O, always in the same order. RESULTS: These findings are attributed to reduced alveolar ventilation and ventilation/perfusion abnormalities and were attenuated with larger tidal volumes. PEEP increases air leak, even with low volume (of 2.0 ± 2.8mL to 31 ± 20.7mL; p= 0.006 and decreases alveolar ventilation in all tidal volumes. Alveolar ventilation improved with larger tidal volumes, but increased fistula output (10 mL/kg - 25.8 ± 18.3mL to 80.2 ± 43.9mL; p=0.0010. Low tidal volumes result in hypercapnia (ZEEP - Toneloto MGC, Terzi RGG, Silva WA, Moraes AC, Moreira MM 83.7± 6.9 mmHg and with PEEP 10 - 93 ± 10.1mmHg and severely decreased arterial oxygen saturation, about of 84%. CONCLUSIONS: The tidal volume of 7 ml/Kg with ZEEP was considered the best tidal volume because, despite moderate hypercapnia

  1. Partial liquid ventilation improves lung function in ventilation-induced lung injury

    NARCIS (Netherlands)

    G.F. Vazquez de Anda; R.A. Lachmann; S.J.C. Verbrugge (Serge); D.A.M.P.J. Gommers (Diederik); J.J. Haitsma (Jack); B.F. Lachmann (Burkhard)

    2001-01-01

    textabstractDisturbances in lung function and lung mechanics are present after ventilation with high peak inspiratory pressures (PIP) and low levels of positive end-expiratory pressure (PEEP). Therefore, the authors investigated whether partial liquid ventilation can re-establish

  2. Influence of posture and positive end-tidal expiratory pressure (PEEP) on clearance of Tc99m-DTPA from the lungs

    International Nuclear Information System (INIS)

    Mason, G.R.; Maublant, J.; Sietsema, K.; Effros, R.M.; Mena, I.

    1984-01-01

    The clearance of Tc99m-DTPA aerosols from the lung has been used to detect and quantitate alterations in the permeability of the pulmonary epithelium. Clearance of the radionuclide is accelerated by both chronic and acute injuries to the lung and by smoking. Several laboratories have reported that Tc99m-DTPA clearance from upper lobes exceeded that from lower lobes in upright subjects. To investigate this phenomenon further the authors studied subjects with simultaneous anterior and posterior cameras in upright and supine positions. In the upright position, clearance from both the anterior and posterior upper regions of interest (ROI's) exceeded the lower regions (-1.64 +- .42 S.D. vs. -0.75 +- .41, anterior, p < .05, n=6), -1.04 +- .23 vs. -0.50 +- .36, posterior. All units = %/min. This difference was not observed in the supine subjects. Clearance from the anterior chest exceeded that from the posterior chest in the supine subjects (-1.28 +- .45 vs. -0.05 +- 1.08) and a small increase in radio-activity was observed in at least one ROI of 5 of 6 subjects from the posterior camera. An increase in activity is likely to be secondary to labeling of blood pool, which would have greatest affect where pulmonary blood volume is largest. Computer processing of the entire lung without observer bias in ROI placement showed similar effects of posture over non-peripheral ROI's. Five subjects breathed on PEEP to cause airspace distention, causing clearance to double. Both dependency and airspace distention appear to influence clearance of aerosolized DTPA, the latter may occur by stretching of epithelial pores

  3. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  4. Positive airway pressure adherence and mask interface in the setting of sinonasal symptoms.

    Science.gov (United States)

    Schell, Amy E; Soose, Ryan J

    2017-10-01

    Despite reports of lower positive pressure adherence rates with oronasal masks, patients with sinonasal problems are often prescribed this interface over a nasal interface. The aim of this study was to characterize the relationship between mask type and therapy adherence in the setting of sinonasal symptoms. Retrospective case series with chart review. We reviewed 328 patients who underwent positive pressure titration between January 2012 and May 2015. Follow-up adherence data were available for 218 patients (66.5%). Multivariate analysis examined whether patients with sinonasal symptoms have improved adherence with oronasal masks compared to nasal or nasal pillow interfaces. At a median follow-up of 95 days, positive pressure adherence in patients with sinonasal symptoms was highest with the nasal pillow interface. When compared with oronasal interfaces, the odds of adequate therapy adherence were >5 times greater with nasal pillow interfaces (odds ratio [OR] = 5.20, 95% confidence interval [CI] = 1.61-16.80, P = .006) and >3 times greater with nasal interfaces (OR = 3.67, 95% CI = 1.20-11.26, P = .02) in these symptomatic patients. The presence of nasal problems does not predict the need for an oronasal mask. Positive pressure adherence rates are higher with nasal and nasal pillow interfaces compared to oronasal masks, even in patients with sinonasal complaints. 4. Laryngoscope, 127:2418-2422, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. High Flow Nasal Cannula Therapy for Improving Obstructive Sleep Apnea: A Case Report

    Directory of Open Access Journals (Sweden)

    Se Joong Kim

    2015-06-01

    Full Text Available Although continuous positive airway pressure is the treatment of choice for obstructive sleep apnea, its compliance is low. Therefore, alternative therapeutic strategies are often required. High flow nasal cannula therapy uses an air compressor to deliver a constant flow of oxygen via the nasal cannula at a maximum of 60 L/m. It can produce positive end expiratory pressure and increase end expiratory pharyngeal pressure, which can help to alleviate upper airway obstruction. This is a case report of high flow nasal cannula therapy for a 71 year-old man. He had an obstructive sleep apnea and severe desaturation but failed to use continuous positive airway pressure. He underwent titration with high flow nasal cannula under polysomnography. Using high flow nasal cannula at an airflow of 45 L/m, his apnea-hypopnea, respiratory arousal and oxygen desaturation were improved. Importantly, he is very compliant with high flow nasal cannula therapy.

  6. Application of the Novel Ventilation Mode FLow-Controlled EXpiration (FLEX): A Crossover Proof-of-Principle Study in Lung-Healthy Patients.

    Science.gov (United States)

    Wirth, Steffen; Springer, Sebastian; Spaeth, Johannes; Borgmann, Silke; Goebel, Ulrich; Schumann, Stefan

    2017-10-01

    Traditionally, mechanical ventilation is achieved via active lung inflation during inspiration and passive lung emptying during expiration. By contrast, the novel FLEX (FLow-controlled EXpiration) ventilator mode actively decreases the rate of lung emptying. We investigated whether FLEX can be used during intraoperative mechanical ventilation of lung-healthy patients. In 30 adult patients scheduled for neurosurgical procedures, we studied respiratory system mechanics, regional ventilation, oxygenation, and hemodynamics during ventilation with and without FLEX at positive end-expiratory pressure (PEEP) of 5 and 7 cm H2O. The FLEX system was integrated into the expiratory limb and modified the expiratory flow profile by continuously changing expiratory resistance according to a computer-controlled algorithm. Mean airway pressure increased with PEEP by 1.9 cm H2O and with FLEX by 1 cm H2O (all P ventilated during general anesthesia. FLEX improves the homogeneous distribution of ventilation in the lungs.

  7. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation.

    Science.gov (United States)

    Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham

    2014-08-01

    To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (prights reserved.

  8. Boussignac continuous positive airway pressure for weaning with tracheostomy tubes

    NARCIS (Netherlands)

    Dieperink, Willem; Aarts, Leon P. H. J.; Rodgers, Michael G. G.; Delwig, Hans; Nijsten, Maarten W. N.

    2008-01-01

    Background: In patients who are weaned with a tracheostomy tube ( TT), continuous positive airway pressure ( CPAP) is frequently used. Dedicated CPAP systems or ventilators with bulky tubing are usually applied. However, CPAP can also be effective without a ventilator by the disposable Bous-signac

  9. Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

    CERN Document Server

    Azevedo, C.D.R.

    2016-12-13

    A study of the gas pressure effect in the position resolution of an interacting X- or gamma-ray photon in a gas medium is performed. The intrinsic position resolution for pure noble gases (Argon and Xenon) and their mixtures with CO2 and CH4 were calculated for several gas pressures (1-10bar) and for photon energies between 5.4 and 60.0 keV, being possible to establish a linear match between the intrinsic position resolution and the inverse of the gas pressure in that energy range. In order to evaluate the quality of the method here described, a comparison between the available experimental data and the calculated one in this work, is done and discussed. In the majority of the cases, a strong agreement is observed.

  10. Association of an adult obesity, blood pressure adulthood socio-economic position.

    Science.gov (United States)

    Siadat, Zahra Dana; Abdoli, Aminreza; Shahsanaee, Armindokht

    2012-03-01

    The purpose of this study is to investigate an effect of childhood and adulthood socio-economic position on selected cardiovascular risk factors including obesity, blood pressure level and smoking behavior. This is a cross-sectional study performed on 479 individuals, randomly selected by random clustered sampling from men and women aged 30-50 years, living in Esfahan. Their demographic characteristics, education, occupation and smoking behavior were questioned. Their weight, height and blood pressure were also measured, and their BMI (Body Mass Index) was calculated. The data were analyzed by SPSS 19 software. In men, the odds ratio for ever smoking to never smoking at higher levels of education in comparison with the lower levels was 6.08 (2.65-14.11). For manual occupation to non-manual occupation, it was 3.55 (1.88-6.68). The odds ratio for obesity and overweight vs no overweight, for manual occupation to non-manual occupation was 3.12 (1.81-5.40) in men and for father's occupation it was 2.03 (1.10-3.74). In women, their education with the odds ratio of 2.11 (1.17-3.82) and father's occupation with the odds ratio of 6.63 (3.50-12.58) altered their chance of being obese or overweight. Also, in women, the mean systolic blood pressure was significantly lower at higher educational levels and in those whose fathers' occupation were manual but lower in manual workers. The current socio-economic position in individuals is associated with an obesity and smoking behavior, particularly in men. Childhood socio-economic position increases the chance of an obesity and higher blood pressure, particularly in women.

  11. Multiple applications of the Boussignac continuous positive airway pressure system

    NARCIS (Netherlands)

    Dieperink, Willem

    2008-01-01

    Continuous positive airway pressure, (CPAP) is a form of treatment to support patients with dyspnea. For the application of CPAP a mechanical ventilator or complex CPAP apparatus is mostly used. The Boussignac CPAP (BCPAP) system developed by George Boussignac does not need such apparatus. The BCPAP

  12. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    International Nuclear Information System (INIS)

    Inoue, Masanori; Hasegawa, Ichiro; Nakano, Keiko; Yamaguchi, Kazuhiro; Kuribayashi, Sachio

    2009-01-01

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV 1.0% ) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV 1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  13. Gravity predominates over ventilatory pattern in the prevention of ventilator-associated pneumonia.

    Science.gov (United States)

    Li Bassi, Gianluigi; Marti, Joan Daniel; Saucedo, Lina; Rigol, Montserrat; Roca, Ignasi; Cabanas, Maria; Muñoz, Laura; Ranzani, Otavio Tavares; Giunta, Valeria; Luque, Nestor; Esperatti, Mariano; Gabarrus, Albert; Fernandez, Laia; Rinaudo, Mariano; Ferrer, Miguel; Ramirez, Jose; Vila, Jordi; Torres, Antoni

    2014-09-01

    In the semirecumbent position, gravity-dependent dissemination of pathogens has been implicated in the pathogenesis of ventilator-associated pneumonia. We compared the preventive effects of a ventilatory strategy, aimed at decreasing pulmonary aspiration and enhancing mucus clearance versus the Trendelenburg position. Prospective randomized animal study. Animal research facility, University of Barcelona, Spain. Twenty-four Large White-Landrace pigs. Pigs were intubated and on mechanical ventilation for 72 hours. Following surgical preparation, pigs were randomized to be positioned: 1) in semirecumbent/prone position, ventilated with a duty cycle (TITTOT) of 0.33 and without positive end-expiratory pressure (control); 2) as in the control group, positive end-expiratory pressure of 5 cm H2O and TITTOT to achieve a mean expiratory-inspiratory flow bias of 10 L/min (treatment); 3) in Trendelenburg/prone position and ventilated as in the control group (Trendelenburg). Following randomization, Pseudomonas aeruginosa was instilled into the oropharynx. Mucus clearance rate was measured through fluoroscopic tracking of tracheal markers. Microspheres were instilled into the subglottic trachea to assess pulmonary aspiration. Ventilator-associated pneumonia was confirmed by histological/microbiological studies. The mean expiratory-inspiratory flow in the treatment, control, and Trendelenburg groups were 10.7 ± 1.7, 1.8 ± 3.7 and 4.3 ± 2.8 L/min, respectively (p gravity-dependent translocation of oropharyngeal pathogens and development of ventilator-associated pneumonia. These findings further substantiate the primary role of gravity in the pathogenesis of ventilator-associated pneumonia.

  14. Effects of hip joint position and intra-capsular volume on hip joint intra-capsular pressure: a human cadaveric model

    Directory of Open Access Journals (Sweden)

    Tse Paul

    2009-04-01

    Full Text Available Abstract Background Increase in hip intra-capsular pressure has been implicated in various hip pathologies, such as avascular necrosis complicating undisplaced femoral neck fracture. Our study aimed at documenting the relationship between intra-capsular volume and pressure in various hip positions. Methods Fifty-two cadaveric hips were studied. An electronic pressure-monitoring catheter recorded the intra-capsular hip pressure after each instillation of 2 ml of normal saline and in six hip positions. Results In neutral hip position, the control position for investigation, intra-capsular pressure remained unchanged when its content was below 10 ml. Thereafter, it increased exponentially. When the intra-capsular volume was 12 ml, full abduction produced a 2.1-fold increase (p = 0.028 of the intra-capsular hip joint pressure; full external rotation and full internal rotation increased the pressure by at least 4-fold (p Conclusion Intra-capsular pressure increases with its volume, but with a wide variation with different positions. It would be appropriate to recommend that hips with haemarthrosis or effusion should be positioned in 45-degree flexion.

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) ... Cystic Fibrosis Foundation 4550 Montgomery Ave. Suite 1100 N Bethesda, MD ...

  16. Thomson scattering in a low-pressure argon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2000-01-01

    The electron density and the electron temperature in a low-pressure argon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 5

  17. Thomson scattering in a low-pressure neon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2001-01-01

    The electron density and the electron temperature in a low-pressure neon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 10

  18. Effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by parkinson?s disease

    OpenAIRE

    Byeon, Haewon

    2016-01-01

    [Purpose] This study aimed to investigate the effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by Parkinson?s disease. [Subjects and Methods] The subjects of this study were 18 patients who received simultaneous application of postural techniques and expiratory muscle strength training and 15 patients who received expiratory muscle strength training only. Postural t...

  19. Early nasal continuous positive airway pressure in a cohort of the smallest infants in Denmark

    DEFF Research Database (Denmark)

    Hansen, Bo M; Esbjørn, Barbara Hoff; Greisen, G

    2004-01-01

    To evaluate neurodevelopmental outcome at age 5 y of age in a cohort of preterm children treated mainly with nasal continuous positive airway pressure (CPAP) in the neonatal period.......To evaluate neurodevelopmental outcome at age 5 y of age in a cohort of preterm children treated mainly with nasal continuous positive airway pressure (CPAP) in the neonatal period....

  20. Effects of pleural effusion drainage on oxygenation, respiratory mechanics, and hemodynamics in mechanically ventilated patients.

    Science.gov (United States)

    Razazi, Keyvan; Thille, Arnaud W; Carteaux, Guillaume; Beji, Olfa; Brun-Buisson, Christian; Brochard, Laurent; Mekontso Dessap, Armand

    2014-09-01

    In mechanically ventilated patients, the effect of draining pleural effusion on oxygenation is controversial. We investigated the effect of large pleural effusion drainage on oxygenation, respiratory function (including lung volumes), and hemodynamics in mechanically ventilated patients after ultrasound-guided drainage. Arterial blood gases, respiratory mechanics (airway, pleural and transpulmonary pressures, end-expiratory lung volume, respiratory system compliance and resistance), and hemodynamics (blood pressure, heart rate, and cardiac output) were recorded before and at 3 and 24 hours (H24) after pleural drainage. The respiratory settings were kept identical during the study period. The mean volume of effusion drained was 1,579 ± 684 ml at H24. Uncomplicated pneumothorax occurred in two patients. Respiratory mechanics significantly improved after drainage, with a decrease in plateau pressure and a large increase in end-expiratory transpulmonary pressure. Respiratory system compliance, end-expiratory lung volume, and PaO2/FiO2 ratio all improved. Hemodynamics were not influenced by drainage. Improvement in the PaO2/FiO2 ratio from baseline to H24 was positively correlated with the increase in end-expiratory lung volume during the same time frame (r = 0.52, P = 0.033), but not with drained volume. A high value of pleural pressure or a highly negative transpulmonary pressure at baseline predicted limited lung expansion following effusion drainage. A lesser improvement in oxygenation occurred in patients with ARDS. Drainage of large (≥500 ml) pleural effusion in mechanically ventilated patients improves oxygenation and end-expiratory lung volume. Oxygenation improvement correlated with an increase in lung volume and a decrease in transpulmonary pressure, but was less so in patients with ARDS.

  1. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  2. Influence of upper body position on middle cerebral artery blood velocity during continuous positive airway pressure breathing

    DEFF Research Database (Denmark)

    Højlund Rasmussen, J; Mantoni, T; Belhage, B

    2007-01-01

    Continuous positive airway pressure (CPAP) is a treatment modality for pulmonary oxygenation difficulties. CPAP impairs venous return to the heart and, in turn, affects cerebral blood flow (CBF) and augments cerebral blood volume (CBV). We considered that during CPAP, elevation of the upper body ...

  3. Nasal continuous positive airway pressure: does bubbling improve gas exchange?

    Science.gov (United States)

    Morley, C J; Lau, R; De Paoli, A; Davis, P G

    2005-07-01

    In a randomised crossover trial, 26 babies, treated with Hudson prong continuous positive airway pressure (CPAP) from a bubbling bottle, received vigorous, high amplitude, or slow bubbling for 30 minutes. Pulse oximetry, transcutaneous carbon dioxide, and respiratory rate were recorded. The bubbling rates had no effect on carbon dioxide, oxygenation, or respiratory rate.

  4. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  5. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Mishra

    2015-01-01

    Full Text Available Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left. The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2 were noted in all positions. Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation, lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups. Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.

  6. Backrest position in prevention of pressure ulcers and ventilator-associated pneumonia: Conflicting recommendations

    OpenAIRE

    Burk, Ruth Srednicki; Jo Grap, Mary

    2012-01-01

    Pressure ulcers and ventilator-associated pneumonia (VAP) are both common in acute and critical care settings and are considerable sources of morbidity, mortality, and health care costs. To prevent pressure ulcers, guidelines limit bed backrest elevation to less than 30 degrees, whereas recommendations to reduce VAP include use of backrest elevations of 30 degrees or more. Although a variety of risk factors beyond patient position have been identified for both pressure ulcers and VAP, this ar...

  7. Segmentation of expiratory and inspiratory sounds in baby cry audio recordings using hidden Markov models.

    Science.gov (United States)

    Aucouturier, Jean-Julien; Nonaka, Yulri; Katahira, Kentaro; Okanoya, Kazuo

    2011-11-01

    The paper describes an application of machine learning techniques to identify expiratory and inspiration phases from the audio recording of human baby cries. Crying episodes were recorded from 14 infants, spanning four vocalization contexts in their first 12 months of age; recordings from three individuals were annotated manually to identify expiratory and inspiratory sounds and used as training examples to segment automatically the recordings of the other 11 individuals. The proposed algorithm uses a hidden Markov model architecture, in which state likelihoods are estimated either with Gaussian mixture models or by converting the classification decisions of a support vector machine. The algorithm yields up to 95% classification precision (86% average), and its ability generalizes over different babies, different ages, and vocalization contexts. The technique offers an opportunity to quantify expiration duration, count the crying rate, and other time-related characteristics of baby crying for screening, diagnosis, and research purposes over large populations of infants.

  8. The effect of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome

    Directory of Open Access Journals (Sweden)

    Giorgiana Dediu

    2017-12-01

    Full Text Available Introduction. Obstructive sleep apnea syndrome (OSAS is a disease with increasing prevalence nowadays, being associated with multiple cardiovascular diseases, such as arterial hypertension. The objective of the study was to evaluate the effect of continuous positive airway pressure (CPAP on blood pressure values. Materials and methods. We performed a prospective interventional study on 52 patients with obstructive sleep apnea syndrome. The patients were divided into 2 groups: Group A (who received both pharmacological and CPAP treatment and Group B (who received only pharmacological treatment, and were followed up at 3 and 6 months. The statistical analysis was made with SPSS and Microsoft Excel. At the same time, using the surrogate marker –RDW, we tried to evaluate the persistence of systemic inflammation, knowing that OSAS is associated with inflammation. Results. The systolic blood pressure values decreased at 6 months in all OSAS patients who have used CPAP, including patients with normal values of blood pressure. At the same time, the lack of OSAS treatment led to increased values of blood pressure by approximately 10 mmHg. We noticed a link between RDW, age and blood pressure values, respectively the increase of RDW and age may result in an increase in blood pressure. Conclusions. The OSAS treatment can decrease the blood pressure values. A higher RDW may be considered a negative prognostic factor for these patients, reflecting the role of systemic inflammation in the appearance of cardiovascular disorders.

  9. EFFECT OF BODY POSITIONS ON INTRA OCULAR PRESSURE

    Directory of Open Access Journals (Sweden)

    Rajendra

    2015-09-01

    Full Text Available BACKGROUND: Intra Ocular Pressure (IOP can be altered by changing body position. Very few studies are available in the Indian subjects. AIM: To study the effect of changes in the body position from upright posture to supine to head down tilt of - 60 0 . MATERIALS AND M ETHODS: The study group consisted of 60 subjects, 35 boys and 25 girls in the age group of 18 to 24 years, with no ocular pathology were chosen. Independent measurements of the IOP of each eye were obtained. Keelar Pulsair air impulse tonometer was used in all the subjects for IOP measurement. IOP was measured in the department of Ophthalmology, Teaching Hospital between 10AM to 12 Noon. STATISTICAL ANALYSIS : were done using Student’s paired ‘t’ test. RESULTS: The change of IOP (Increased induced by the change of position between the means of IOP’s for the sitting and supine positions was 2.789±1.03 mm Hg of all subjects, 2.825±0.226 mm Hg in males and 2.739±0.089 mm Hg in females and between the supine and in clined - 60 ⁰ position was 4.971±0.914 mm Hg of all subjects, 4.703±0.816mm Hg in males and 5.346±1.098 mm Hg in females. CONCLUSION: It is apparent that, the IOP is significantly higher in the supine than in the sitting and in the inclined than in the supin e positions. The difference was statistically significant (P<0.001.

  10. A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators

    Science.gov (United States)

    Thille, Arnaud W.; Lyazidi, Aissam; Richard, Jean-Christophe M.; Galia, Fabrice; Brochard, Laurent

    2009-01-01

    Objective To compare 13 commercially available, new-generation, intensive-care-unit (ICU) ventilators regarding trigger function, pressurization capacity during pressure-support ventilation (PSV), accuracy of pressure measurements and expiratory resistance. Design and Setting Bench study at a research laboratory in a university hospital. Material Four turbine-based ventilators and nine conventional servo-valve compressed-gas ventilators were tested using a two-compartment lung model. Results Three levels of effort were simulated. Each ventilator was evaluated at four PSV levels (5, 10, 15, and 20 cm H2O), with and without positive end-expiratory pressure (5 cm H2O, Trigger function was assessed as the time from effort onset to detectable pressurization. Pressurization capacity was evaluated using the airway pressure-time product computed as the net area under the pressure-time curve over the first 0.3 s after inspiratory effort onset. Expiratory resistance was evaluated by measuring trapped volume in controlled ventilation. Significant differences were found across the ventilators, with a range of triggering-delay from 42 ms to 88 ms for all conditions averaged (Pventilators at PSV5 and three at PSV10, suggesting an inability to unload patient’s effort. On average, turbine-based ventilators performed better than conventional ventilators, which showed no improvement compared to a 2000 bench comparison. Conclusion Technical performances of trigger function, pressurization capacity and expiratory resistance vary considerably across new-generation ICU ventilators. ICU ventilators seem to have reached a technical ceiling in recent years, and some ventilators still perform inadequately. PMID:19352622

  11. Effect of Filters on the Noise Generated by Continuous Positive Airway Pressure Delivered via a Helmet

    Directory of Open Access Journals (Sweden)

    Ricardo Hernández-Molina

    2017-01-01

    Full Text Available Introduction: One of the problems that the delivery of continuous positive airway pressure (CPAP via a helmet poses is the generation of noise. The objective of our study was to assess the effect that the use of filter has on sound pressure levels generated by the delivery of positive airway pressure at different gas flow rates. Materials and Methods: Sound pressure levels generated by neonatal helmet CPAP delivery were measured at different gas flows (20, 30, and 40 l/min with and without a breathing filter. Noise intensity was measured by installing microphones in the inner ear of dummy heads wearing helmets. Results: The sound pressure level increased by 38% at a gas flow of 40 l/min, as compared to a gas flow of 20 l/min {74 dBA [interquartile range (IQR 2,2] vs 52 dBA (IQR 5,9, respectively}. Using the breathing filter as a diffuser has a variety of effects on sound pressure levels according to the gas flow rate. Conclusion: The intensity of the noise generated by helmet delivery of positive airway pressure depends on the type of helmet used, gas flow, and use or not of a diffuser filter. Breathing filters with gas flows over 30 l/min might not be recommended since they would not attenuate but will rather amplify sound pressure.

  12. Impact of Polysomnographic Parameters on Continuous Positive Airway Pressure in Patient with Obstructive Sleep Apnea in 2012

    Directory of Open Access Journals (Sweden)

    Abolfazl Mozafari

    2014-06-01

    Full Text Available Background & objectives : O bstructive sleep apnea is a preventable and prevalent major health hazard with serious health consequences including excessive daytime sleepiness, cognitive disturbances, depression, cardiovascular diseases and hypertension. Obstructive sleep apnea is a disorder affecting 2 to 4% of the adult population. The continuous positive airway pressur e (CPAP i s the most efficacious therapy and is often the first option for these patients. The pressure titration during laboratory polysomnography is required for treatment by CPAP.   Methods: The patients with obstructive sleep apnea requiring continuous positive airway pressure treatment were selected . CPAP titration was done according to American Academy of Sleep Medicine protocol. Comparison among continuous positive airway pressure with polysomnographic parameters was performed and analyzed with Pearson correlation coefficient. For analysis of qualitative parameters, we used chi-square and then checked with SPSS version 18 software.   Results: From 125 patients with obstructive sleep apnea, there were 112 cases with inclusion criteria. Mean age of participants was 55.07 ± 12, male frequency was 59.2%, apnea hypopnea index was 43.62 and mean continuous positive airway pressure was 12.50 . There was significant relationship among the pressure of continuous positive airway pressure with apnea hypopnea index (P=0.028, arousal index (P=0.011, body mass index (P=0.041 and O2 desaturation index (P=0.022, although age was not significantly related.   Conclusion: In accordance to this data, we found out a prediction equation for optimal CPAP in our patients

  13. Lung volume and expiratory flow rates from pre- to post-puberty.

    Science.gov (United States)

    Smith, Joshua R; Emerson, Sam R; Kurti, Stephanie P; Gandhi, Kirti; Harms, Craig A

    2015-08-01

    The purpose was to determine if the airways and lungs grow disproportionately from pre- to post-puberty in boys and girls. We hypothesized that the airways grow at a slower rate than lung volume (i.e. dysanapsis growth) during puberty and boys would exhibit more dysanaptic growth compared to girls. Twenty-one pre-pubescent children [11 boys (pre 10.1 ± 0.5 years, post 15.3 ± 0.5 years); 10 girls (pre 9.4 ± 1.0 years, post 14.1 ± 1.0 years)] performed pulmonary function tests (PFTs) ~5 years ago from an original cohort of 40 children. These 21 children performed PFTs, which included forced vital capacity (FVC) and forced expiratory flow at 50 % FVC (FEF50). Static pressure at 50 % of FVC [Pst(L)50 %] was estimated based on age. Dysanapsis ratio (DR) was calculated [FEF50 × FVC(-1) × Pst(L) 50 % (-1) ]. Maturation status was determined via Tanner stages. Stage of maturation was not different (p > 0.05) between boys and girls (4.2 ± 0.6 stage vs. 3.7 ± 0.7 stage, respectively). FVC and FEF50 increased (p 0.05) from pre- to post-puberty. FEF50 and FVC significantly increased and DR decreased (p puberty for both sexes. Post-puberty, boys had a significantly larger FVC, but FEF50, DR, and FEF50/FVC were not different (p > 0.05) compared to girls. These data suggest that dysanaptic growth occurs during puberty and that it is not different between boys and girls.

  14. Cardiorespiratory effects of balancing PEEP with intra-abdominal pressures during laparoscopic cholecystectomy.

    Science.gov (United States)

    Kundra, Pankaj; Subramani, Yamini; Ravishankar, M; Sistla, Sarath C; Nagappa, Mahesh; Sivashanmugam, T

    2014-06-01

    Applying appropriate positive end-expiratory pressure (PEEP) to corresponding intra-abdominal pressure (IAP) can improve gas exchange during capnoperitoneum without any hemodynamic effects. A total of 75 patients were randomly allocated to group 0PEEP (n=25), group 5PEEP (n=25), and group 10PEEP (n=25) according to the level of PEEP, in whom capnoperitoneum was created with IAP of 14, 8, and 14 mm Hg, respectively. Hemodynamic and respiratory parameters were recorded up to 30 minutes after capnoperitoneum. In 0PEEP group, mean end-tidal carbon dioxide demonstrated significant rise 2 minutes after capnoperitoneum and plateaued at about 15 minutes but remained at high level for up to 30 minutes when compared with the 5PEEP and 10PEEP groups (Phigher at 30 minutes when compared with 5PEEP (37.8±2.7 mm Hg) and 10PEEP (37.2±3.9 mm Hg) groups. The oxygenation was better preserved in 5PEEP and 10PEEP groups with significantly higher PaO2/Fio2 ratio. Heart rate, mean arterial pressure, and cardiac output remained stable throughout the study in all the 3 groups. Application of appropriate PEEP corresponding to the IAP helped maintain CO2 elimination and improved oxygenation without any hemodynamic disturbance in patients undergoing laparoscopic cholecystectomy.

  15. Evaluation of changes in central airway dimensions, lung area and mean lung density at paired inspiratory/expiratory high-resolution computed tomography

    International Nuclear Information System (INIS)

    Ederle, J.R.; Heussel, C.P.; Hast, J.; Ley, S.; Thelen, M.; Kauczor, H.U.; Fischer, B.; Beek, E.J.R. van

    2003-01-01

    The aim of this study was to improve the understanding of interdependencies of dynamic changes in central airway dimensions, lung area and lung density on HRCT. The HRCT scans of 156 patients obtained at full inspiratory and expiratory position were evaluated retrospectively. Patients were divided into four groups according to lung function tests: normal subjects (n=47); obstructive (n=74); restrictive (n=19); or mixed ventilatory impairment (n=16). Mean lung density (MLD) was correlated with cross-sectional area of the lung (CSA L ), cross-sectional area of the trachea (CSA T ) and diameter of main-stem bronchi (D B ). The CSA L was correlated with CSA T and D B . MLD correlated with CSA L in normal subjects (r=-0.66, p T in the control group (r=-0.50, p B was found (r=-0.52, p L and CSA T correlated in the control group (r=0.67, p L and D B correlated in the control group (r=0.42, p<0.0001) and in patients with obstructive lung disease (r=0.24, p<0.05). Correlations for patients with restrictive and mixed lung disease were constantly lower. Dependencies between central and peripheral airway dimensions and lung parenchyma are demonstrated by HRCT. Best correlations are observed in normal subjects and patients with obstructive lung disease. Based on these findings we postulate that the dependencies are the result of air-flow and pressure patterns. (orig.)

  16. Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

    Directory of Open Access Journals (Sweden)

    Daniela Franco Rizzo Komatsu

    Full Text Available Summary Objective: To analyze the frequency of extubation failure in premature infants using conventional mechanical ventilation (MV after extubation in groups subjected to nasal intermittent positive pressure ventilation (nIPPV and continuous positive airway pressure (nCPAP. Method: Seventy-two premature infants with respiratory failure were studied, with a gestational age (GA ≤ 36 weeks and birth weight (BW > 750 g, who required tracheal intubation and mechanical ventilation. The study was controlled and randomized in order to ensure that the members of the groups used in the research were chosen at random. Randomization was performed at the time of extubation using sealed envelopes. Extubation failure was defined as the need for re-intubation and mechanical ventilation during the first 72 hours after extubation. Results: Among the 36 premature infants randomized to nIPPV, six (16.6% presented extubation failure in comparison to 11 (30.5% of the 36 premature infants randomized to nCPAP. There was no statistical difference between the two study groups regarding BW, GA, classification of the premature infant, and MV time. The main cause of extubation failure was the occurrence of apnea. Gastrointestinal and neurological complications did not occur in the premature infants participating in the study. Conclusion: We found that, despite the extubation failure of the group of premature infants submitted to nIPPV being numerically smaller than in premature infants submitted to nCPAP, there was no statistically significant difference between the two modes of ventilatory support after extubation.

  17. Mechanical ventilation management during extracorporeal membrane oxygenation for acute respiratory distress syndrome: a retrospective international multicenter study.

    Science.gov (United States)

    Schmidt, Matthieu; Stewart, Claire; Bailey, Michael; Nieszkowska, Ania; Kelly, Joshua; Murphy, Lorna; Pilcher, David; Cooper, D James; Scheinkestel, Carlos; Pellegrino, Vincent; Forrest, Paul; Combes, Alain; Hodgson, Carol

    2015-03-01

    To describe mechanical ventilation settings in adult patients treated for an acute respiratory distress syndrome with extracorporeal membrane oxygenation and assess the potential impact of mechanical ventilation settings on ICU mortality. Retrospective observational study. Three international high-volume extracorporeal membrane oxygenation centers. A total of 168 patients treated with extracorporeal membrane oxygenation for severe acute respiratory distress syndrome from January 2007 to January 2013. We analyzed the association between mechanical ventilation settings (i.e. plateau pressure, tidal volume, and positive end-expiratory pressure) on ICU mortality using multivariable logistic regression model and Cox-proportional hazards model. We obtained detailed demographic, clinical, daily mechanical ventilation settings and ICU outcome data. One hundred sixty-eight patients (41 ± 14 years old; PaO2/FIO2 67 ± 19 mm Hg) fulfilled our inclusion criteria. Median duration of extracorporeal membrane oxygenation and ICU stay were 10 days (6-18 d) and 28 days (16-42 d), respectively. Lower positive end-expiratory pressure levels and significantly lower plateau pressures during extracorporeal membrane oxygenation were used in the French center than in both Australian centers (23.9 ± 1.4 vs 27.6 ± 3.7 and 27.8 ± 3.6; p Protective mechanical ventilation strategies were routinely used in high-volume extracorporeal membrane oxygenation centers. However, higher positive end-expiratory pressure levels during the first 3 days on extracorporeal membrane oxygenation support were independently associated with improved survival. Further prospective trials on the optimal mechanical ventilation strategy during extracorporeal membrane oxygenation support are warranted.

  18. Pars-plana fluid aspiration for positive vitreous cavity pressure in anterior segment surgeries

    Directory of Open Access Journals (Sweden)

    Thomas Kuriakose

    2018-01-01

    Full Text Available Positive vitreous pressure due to misdirection of aqueous or choroidal effusion leads to shallowing of the anterior chamber (AC before or during anterior segment surgeries. This shallow AC if not addressed makes surgery difficult and increases the risk of surgical complications. Methods to prevent and manage this condition described in literature are not without problems. We describe a minimally invasive technique of passing a 30G needle through the pars-plana to aspirate misdirected fluid from vitreous cavity either as a prophylaxis just before surgery or during it, thereby decreasing positive vitreous pressure. This technique, used in 12 eyes, seems to be effective in patients with angle-closure glaucoma, malignant glaucoma, and per-operative sudden increase in vitreous pressure during surgery. Small-incision surgeries are ideally suited for this procedure. This minimally invasive technique is simple to perform and complications are unlikely to be more than what is seen with intravitreal injections.

  19. Clinical predictors of central sleep apnea evoked by positive airway pressure titration.

    Science.gov (United States)

    Moro, Marilyn; Gannon, Karen; Lovell, Kathy; Merlino, Margaret; Mojica, James; Bianchi, Matt T

    2016-01-01

    Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%-15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management. We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split-night; n=306 two-night). Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG) data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI) ≥5 during split-night PSG (SN-PSG) versus full-night PSG (FN-PSG) titrations. CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients. Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the laboratory setting, even as PSG remains the gold standard for characterizing primary central apnea and TECSA.

  20. Inspiratory time and tidal volume during intermittent positive pressure ventilation.

    OpenAIRE

    Field, D; Milner, A D; Hopkin, I E

    1985-01-01

    We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.

  1. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

    Science.gov (United States)

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.

  2. Dead space and slope indices from the expiratory carbon dioxide tension-volume curve

    OpenAIRE

    Kars, Alice; Bogaard, Jan; Stijnen, Theo; Vries, J.; Verbraak, Anton; Hilvering, C.

    1997-01-01

    textabstractThe slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate (PIE), were investigated in 28 healthy control subjects, 12 asthma and 29 emphysema patients (20 severely obstructed and nine moderately obstructed) with the aim to establish diagnostic value. Because breath volume and frequenc...

  3. Cardiovascular regulation during body unweighting by lower body positive pressure.

    Science.gov (United States)

    Evans, Joyce M; Mohney, Lindsay; Wang, Siqi; Moore, Rachel K; Elayi, Samy-Claude; Stenger, Michael B; Moore, Fritz B; Knapp, Charles F

    2013-11-01

    We hypothesized that human cardiovascular responses to standing in reduced gravity environments, as on the Moon or Mars, could be modeled using a lower body positive pressure (LBPP) chamber. Heart rate, blood pressure, body segment fluid shifts, ECG, indexes of sympathetic, parasympathetic balance, and baroreflex control of the heart and periphery plus echocardiographic measures of cardiac function were recorded from seven men and seven women supine and standing at 100% (Earth), 40% (-Mars), and 20% (-Moon) bodyweights (BW). The fluid shifted from the chest was greater when standing at 100% BW than at 20% and 40% BW, while fluid pooled in the abdomen was similar at all BWs. Compared to moving from supine to standing at 100% BW, moving to 20% and 40% BW resulted in smaller decreases in stroke volume and pulse pressure, smaller increases in heart rate and smaller decreases in parasympathetic control of heart rate, baroreflex slope, numbers of blood pressure ramps, and much reduced indexes of sympathetic drive to the heart and periphery. However, peripheral vascular resistance, systolic pressure, and baroreflex effectiveness were elevated during 20% and 40% BW, compared to supine and standing at 100% BW. Standing at reduced bodyweight suppressed indexes of sympathetic control of heart rate and peripheral vasomotion. Regulatory responses indicated a combination of arterial and cardiopulmonary baroreflex control: mean heart rate, vasomotion, and baroreflex sensitivity appeared to be more under cardiopulmonary control while baroreflex effectiveness appeared to be driven more by the arterial baroreflex.

  4. The correlation between the paired inspiratory and expiratory three-dimensional quantitative CT and pulmonary function test in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Sui Xi; Song Wei; Xue Huadan; Song Lan; Yang Liang; Jin Zhengyu

    2013-01-01

    Objective: To investigate the correlation between the paired inspiratory and expiratory quantitative CT and pulmonary function tests (PFTs) in patients with chronic obstructive pulmonary disease (COPD). Methods: A total of 84 patients with COPD were enrolled. For each patient, CT scan was performed in deep inspiration and expiration. Using automatic post-processing software, a three-dimension quantitative measurement was employed to assess the CT parameters of emphysema and air trapping. The correlation between CT and PFT was evaluated by the Spearman rank correlation test and multivariate linear regression analysis. Results: The percent 1 [Perc_1, (-984.28 ± 17.93) HU] and percent 15 [Perc_1_5, (-948.35 ± 22.26) HU] from the CT parameters of emphysema were positively correlated with the forced expiratory volume in 1 second predicted (FEV_1%, 48.69 ± 23, 47), the ratio of forced expiratory volume in 1 second over forced vital capacity [FEV_1/FVC, (45.89 ± 15.36)%, r = 0.45-0.67, P < 0.01], was negatively correlated with the ratio of residual volume to total lung capacity [RV/TLC, (61.32 ± 14.48)%]. The other CT parameters of emphysema index (EI) and the parameters of air trapping, the change in relative lung volume with attenuation values from -860 to -950 HU [RVC_-_8_6_0_-_-_9_5_0, (17.66 ± 22.36)%], the expiration to inspiration ratio of mean lung density (MLD_e_x_/_i_n, 0.93 ± 0.06), the expiration to inspiration ratio of lung volume (LV_e_x_/_i_n, 0.71 ± 0.14) had negative correlations with logFEV_1%, FEV_1/FVC (r = -0.48--0.69, P < 0.01) and positive correlations with RV/TLC (r = 0.41-0.66, P < 0.01). The further univariate linear regressions showed that EI, Perc_1, Pere_1_5, RVC_-_8_6_0_-_-_9_5_0, MLD_e_x_/_i_n, LV_e_x_/_i_n were correlated with the parameters of PFTs (R square values of the regression equation, ranged from 0.27 to 0.66, P < 0.01). After the pairwise combinations of the parameters of emphysema and air trapping, multivariate stepwise

  5. Maximal respiratory pressures and pulmonary function in male runners.

    OpenAIRE

    Cordain, L; Glisan, B J; Latin, R W; Tucker, A; Stager, J M

    1987-01-01

    To determine the effects of long term exercise on respiratory muscle strength, maximal inspiratory (Pl max) and expiratory (PE max) pressures, pulmonary volumes and capacities and anthropometric parameters were measured in a group of 101 male runners aged 16 to 58 years. The runners exhibited significantly (p less than 0.05) lower PE max (202 +/- 41 cm H2O and significantly greater residual lung volumes (RV) (2.08 +/- 0.49 L) than predicted values for normal subjects of similar height and age...

  6. TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, R; Sanada, S [Kanazawa University, Kanazawa, Ishikawa (Japan); Sakuta, K; Kawashima, H [Kanazawa University Hospital, Kanazawa, Ishikawa (Japan); Kishitani, Y [TOYO Corporation, Chuoh-ku, Tokyo (Japan)

    2015-06-15

    Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer. After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography combined

  7. Respiratory training during rehabilitation of acute organic fluorine-poisoned patients treated by non-invasive positive pressure ventilation.

    Science.gov (United States)

    Liu, L; Liu, D Z; Wang, Q P; Zhu, Z L; Li, H M; Lu, X Y

    2017-01-01

    This paper aimed to analyze the effects of respiratory training on pulmonary function during the rehabilitation period for acute organic fluorine-poisoned patients treated by non-invasive positive pressure ventilation (NIPPV). Sixty-two acute organic fluorine-poisoned patients admitted to the Xinxiang Central Hospital, Xinxiang City, China, from May 2012 to March 2016 were selected and randomly divided into an observation group and a control group, with 31 cases in each. Both groups received NIPPV. The patients in the control group exercised daily, while the patients in the observation group received contracting lips-abdominal breathing training. The therapeutic effects, pulmonary ventilation function, serum levels of α-antitrypsin1 (α-AT1), surfactant protein D (SP-D), neutrophil elastase (NE), transforming growth factor beta 1 (TGF-β1), and quality of life were analyzed and compared between the two groups both before and after the administration of treatment. The total effective rate of the observation group was 93.55%, which was significantly higher when compared with the control group (74.19%) (P less than 0.05). The levels of forced expiratory volume in one second (FEV1), FEV1/FVC ratio, vital capacity (VC), carbon monoxide diffusion capacity (DLco), and maximal voluntary ventilation (MVV) of the observation group were better when compared with the control group and had statistical significance (P less than 0.05). Before treatment, the serum levels of α-AT1, SP-D, NE, and TGF-β1, and quality of life had no statistical significance in either group (P>0.05); after treatment, these indexes and the quality of life for the observation group were significantly higher when compared with the control group, with statistical significance (P less than 0.05). The respiratory training in acute organic fluorine-poisoned patients treated by NIPPV can improve the serum indexes, dilute toxicity, and recover pulmonary function, which play key roles in improving the

  8. Variations of Blood Pressure in Stroke Unit Patients May Result from Alternating Body Positions

    NARCIS (Netherlands)

    Aries, M.J.H.; Elting, Jan Willem; Stewart, Roy E.; de Keyser, Jacques; Thien, Theo; Kremer, Berry P.; Vroomen, Patrick C. A. J.

    Background: Blood pressure (BP) is one of the major vital parameters monitored in the stroke unit. The accuracy of indirect BP measurement is strongly influenced by the position of both patient and arm during the measurement. Acute stroke patients are often nursed in lateral decubitus positions. The

  9. Adherence to continuous positive airway pressure in adults with an intellectual disability

    NARCIS (Netherlands)

    Luijks, K.A.; Vandenbussche, N.L.; Pevernagie, D.; Overeem, S.; Pillen, S.

    STUDY OBJECTIVES: This retrospective study evaluated the feasibility of continuous positive airway pressure (CPAP) therapy in adults with intellectual disabilities (ID). METHODS: CPAP therapy of 24 obstructive sleep apnea syndrome (OSA) patients with ID were compared to age- and sex-matched adults

  10. Effects of non-fatiguing respiratory muscle loading induced by expiratory flow limitation during strenuous incremental cycle exercise on metabolic stress and circulating natural killer cells.

    Science.gov (United States)

    Rolland-Debord, Camille; Morelot-Panzini, Capucine; Similowski, Thomas; Duranti, Roberto; Laveneziana, Pierantonio

    2017-12-01

    Exercise induces release of cytokines and increase of circulating natural killers (NK) lymphocyte during strong activation of respiratory muscles. We hypothesised that non-fatiguing respiratory muscle loading during exercise causes an increase in NK cells and in metabolic stress indices. Heart rate (HR), ventilation (VE), oesophageal pressure (Pes), oxygen consumption (VO 2 ), dyspnoea and leg effort were measured in eight healthy humans (five men and three women, average age of 31 ± 4 years and body weight of 68 ± 10 kg), performing an incremental exercise testing on a cycle ergometer under control condition and expiratory flow limitation (FL) achieved by putting a Starling resistor. Blood samples were obtained at baseline, at peak of exercise and at iso-workload corresponding to that reached at the peak of FL exercise during control exercise. Diaphragmatic fatigue was evaluated by measuring the tension time index of the diaphragm. Respiratory muscle overloading caused an earlier interruption of exercise. Diaphragmatic fatigue did not occur in the two conditions. At peak of flow-limited exercise compared to iso-workload, HR, peak inspiratory and expiratory Pes, NK cells and norepinephrine were significantly higher. The number of NK cells was significantly related to ΔPes (i.e. difference between the most and the less negative Pes) and plasmatic catecholamines. Loading of respiratory muscles is able to cause an increase of NK cells provided that activation of respiratory muscles is intense enough to induce a significant metabolic stress.

  11. Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission

    DEFF Research Database (Denmark)

    To, G.N.S.; Wan, M.P.; Chao, C.Y.H.

    2009-01-01

    The dispersion and deposition characteristics of polydispersed expiratory aerosols were investigated in an aircraft cabin mockup to study the transmission of infectious diseases. The airflow was characterized by particle image velocimetry (PIV) measurements. Aerosol dispersionwas measured...

  12. Peak expiratory flow as a predictor for the effectiveness of sport for patients with COPD.

    Science.gov (United States)

    Jungblut, S; Frickmann, H; Klingler, J; Zimmermann, B; Bargon, Joachim

    2006-01-31

    This study intended to find simple parameters that were able to determine the increase in physical performance as a result of sport in a group of patients with COPD (lung sport). We regularly investigated pulse, oxygenation and peak expiratory flow in participants with COPD of a "lung sport group", who participated in a structured weekly training program under professional supervision. Ten volunteers (7 females, 3 males, median of age = 69) with COPD (grade II-III) took part in the study. - The relative changes after 3 and 6 months were compared with the values of the first month of exercise. Measurements were carried out before exercise, after stamina training and at the end of the program. - Pulse and oxygenation did not show any changes. However, there was a significant improvement of peak flow after 6 months. - These peak flow changes represent further evidence of positive effects of sport in COPD and provide a parameter which allows the patients themselves to measure and evaluate the success of their physical activity.

  13. Inhibitory Effect of Nasal Intermittent Positive Pressure Ventilation on Gastroesophageal Reflux.

    Directory of Open Access Journals (Sweden)

    Danny Cantin

    Full Text Available Non-invasive intermittent positive pressure ventilation can lead to esophageal insufflations and in turn to gastric distension. The fact that the latter induces transient relaxation of the lower esophageal sphincter implies that it may increase gastroesophageal refluxes. We previously reported that nasal Pressure Support Ventilation (nPSV, contrary to nasal Neurally-Adjusted Ventilatory Assist (nNAVA, triggers active inspiratory laryngeal closure. This suggests that esophageal insufflations are more frequent in nPSV than in nNAVA. The objectives of the present study were to test the hypotheses that: i gastroesophageal refluxes are increased during nPSV compared to both control condition and nNAVA; ii esophageal insufflations occur more frequently during nPSV than nNAVA. Polysomnographic recordings and esophageal multichannel intraluminal impedance pHmetry were performed in nine chronically instrumented newborn lambs to study gastroesophageal refluxes, esophageal insufflations, states of alertness, laryngeal closure and respiration. Recordings were repeated without sedation in control condition, nPSV (15/4 cmH2O and nNAVA (~ 15/4 cmH2O. The number of gastroesophageal refluxes recorded over six hours, expressed as median (interquartile range, decreased during both nPSV (1 (0, 3 and nNAVA [1 (0, 3] compared to control condition (5 (3, 10, (p < 0.05. Meanwhile, the esophageal insufflation index did not differ between nPSV (40 (11, 61 h-1 and nNAVA (10 (9, 56 h-1 (p = 0.8. In conclusion, nPSV and nNAVA similarly inhibit gastroesophageal refluxes in healthy newborn lambs at pressures that do not lead to gastric distension. In addition, the occurrence of esophageal insufflations is not significantly different between nPSV and nNAVA. The strong inhibitory effect of nIPPV on gastroesophageal refluxes appears identical to that reported with nasal continuous positive airway pressure.

  14. The impact of aerosolized mucolytic agents on the airflow resistance of bacterial filters used in mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Han-Chung Hu

    2015-08-01

    Conclusion: This study demonstrated the aerosolized mucolytic agents could increase the pressure drop of the bacterial filters during mechanical ventilation. The pressure drop of the bacterial filters was higher with 10% acetylcysteine. It is critical to continuously monitor the expiration resistance, auto-positive end-expiratory pressure, and ventilator output waveform when aerosolized 10% acetylcysteine was used in mechanical ventilation patients.

  15. A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system.

    Science.gov (United States)

    Trevisanuto, Daniele; Grazzina, Nicoletta; Doglioni, Nicoletta; Ferrarese, Paola; Marzari, Francesco; Zanardo, Vincenzo

    2005-06-01

    We compared the effectiveness of a new continuous positive airway pressure (CPAP) device (neonatal helmet CPAP) with a conventional nasal CPAP system in preterm neonates needing continuous distending pressure. Randomized, physiological, cross-over study in a tertiary referral, neonatal intensive care unit in a university teaching hospital. Twenty very low birth weight infants with a postnatal age greater than 24 h who were receiving nasal CPAP for apnea and/or mild respiratory distress were enrolled. CPAP delivered by neonatal helmet CPAP and nasal CPAP in random order for two subsequent 90-min periods. Were continuously measured the Neonatal Infant Pain Scale (NIPS) score, oxygen requirements, respiratory rate, heart rate, oxygen saturation, transcutaneous PO(2) (tcPO(2)) and PCO(2) (tcPCO(2)), blood pressure, and desaturations. NIPS scores were significantly lower when the infants were on the neonatal helmet CPAP than when they were on nasal CPAP (0.26+/-0.07 vs. 0.63+/-0.12). The other studied parameters did not differ between the two CPAP modes. The number of desaturations was reduced during the neonatal helmet CPAP treatment (18 vs. 32), although this difference was not significant. In this short-term physiological study the neonatal helmet CPAP appears to be as good as the golden standard for managing preterm infants needing continuous distending pressure, with enhanced tolerability. Further evaluation in a randomized clinical trial is needed to confirm these findings.

  16. Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Hayato Tomita

    Full Text Available The aim of this study was to investigate physiological changes in cardiac area and diameters between inspiratory and expiratory chest computed tomography (CT, and to assess their correlation with lung size change and influence on cardiothoracic ratio (CTR measurements.The institutional review board of our institution approved this study, and informed consent was waived. Forty-three subjects underwent inspiratory and expiratory chest CT as part of routine clinical care. On both inspiratory and expiratory scans, lung volumes and maximum lung diameters (transverse and vertical directions were measured. The maximum cardiac cross-sectional area (CSA and the maximum transverse cardiac diameter were measured on both scans, and the CT-based CTR was calculated. Changes in the lung and cardiac measurements were expressed as the expiratory/inspiratory (E/I ratios. Comparisons between inspiratory and expiratory measurements were made by the Wilcoxon signed-rank test. Correlations between the E/I ratios of lung and heart measurements were evaluated by Spearman's rank correlation analysis.Cardiac CSA and transverse cardiac diameter was significantly larger on expiratory than on inspiratory CT (p < 0.0001. Significant negative correlations were found between the E/I ratios of these cardiac measurements and the E/I ratios of lung volume and vertical lung diameter (p < 0.01. CT-based CTR was significantly larger on expiration than on inspiration (p < 0.0001.Heart size on chest CT depends on the phase of ventilation, and is correlated with changes in lung volume and craniocaudal lung diameter. The CTR is also significantly influenced by ventilation.

  17. Nitroglycerine and patient position effect on central, hepatic and portal venous pressures during liver surgery.

    Science.gov (United States)

    Sand, L; Lundin, S; Rizell, M; Wiklund, J; Stenqvist, O; Houltz, E

    2014-09-01

    To reduce blood loss during liver surgery, a low central venous pressure (CVP) is recommended. Nitroglycerine (NG) with its rapid onset and offset can be used to reduce CVP. In this study, the effect of NG on portal and hepatic venous pressures (PVP and HVP) in different body positions was assessed. Thirteen patients undergoing liver resection were studied. Cardiac output (CO), mean arterial pressure (MAP) and CVP were measured. PVP and HVP were measured using tip manometer catheters at baseline (BL) in horizontal position; during NG infusion, targeting a MAP of 60 mmHg, with NG infusion and the patient placed in 10 head-down position. NG infusion reduced HVP from 9.7 ± 2.4 to 7.2 ± 2.4, PVP from 12.3 ± 2.2 to 9.7 ± 3.0 and CVP from 9.8 ± 1.9 to 7.2 ± 2.1 mmHg at BL. Head-down tilt during ongoing NG resulted in increases in HVP to 8.2 ± 2.1, PVP to 10.7 ± 3 and CVP to 11 ± 1.9 mmHg. CO at BL was 6.3 ± 1.1, which was reduced by NG to 5.8 ± 1.2. Head-down tilt together with NG infusion restored CO to 6.3 ± 1.0 l/min. NG infusion leads to parallel reductions in CVP, HVP and PVP at horizontal body position. Thus, CVP can be used to guide NG dosage and fluid administration at horizontal position. NG infusion can be used to reduce HVP. Head-down tilt can be used during NG infusion to improve both blood pressure and CO without substantial increase in liver venous pressure. In head-down tilt, CVP dissociates from HVP and PVP. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Positive airway pressure treatment

    Science.gov (United States)

    ... it. After using PAP regularly, you may notice: Better concentration and memory Feeling more alert and less sleepy during the day Improved sleep for your bed partner Being more productive at ... and a better mood Normal sleep patterns Lower blood pressure (in ...

  19. Sibutramine versus continuous positive airway pressure in obese obstructive sleep apnoea patients.

    Science.gov (United States)

    Ferland, A; Poirier, P; Sériès, F

    2009-09-01

    The aim of the present study was to compare the efficacy of 1 yr of sibutramine-induced weight loss versus continuous positive airway pressure (CPAP) treatment on sleep-disordered breathing, cardiac autonomic function and systemic blood pressure in obese patients with obstructive sleep apnoea. Subjects with a body mass index of > or =30 kg.m(-2) without previous treatment for obstructive sleep apnoea underwent either sibutramine (n = 22) or CPAP (n = 18) treatment for 1 yr. Sibutramine induced a 5.4+/-1.4 kg decrease in body weight compared to the CPAP group, in which no changes in anthropometric variables were observed. The CPAP treatment improved all sleep and respiratory variables, whereas sibutramine-induced weight loss improved only nocturnal arterial oxygen saturation profile. Only CPAP treatment improved night-time systolic and diastolic blood pressure and 24-h and daytime ambulatory diastolic blood pressure. Sibutramine-induced weight loss had no impact on indices of heart rate variability, whereas CPAP treatment increased daytime time domain indices. CPAP treatment for 1 yr had beneficial impacts on nocturnal breathing disturbances, and improved nocturnal oxygenation, night-time systolic and diastolic blood pressure, and daytime cardiac parasympathetic modulation. Sibutramine did not improve sleep-disordered breathing, systemic blood pressure or heart rate variability. There were no adverse effects, such as increment in blood pressure or arrhythmias, associated with this treatment regimen.

  20. Peak expiratory flow rate in healthy children aged 6-17 years

    DEFF Research Database (Denmark)

    Høst, A; Høst, A H; Ibsen, T

    1994-01-01

    Peak expiratory flow rate (PEFR) was measured in a cross-sectional study in 861 healthy Danish schoolchildren aged 6-17 years using a Mini Wright peak flowmeter. We found a strong correlation between PEFR and height, age and sex. The results were comparable with those from previous studies using...... a Wright peak flowmeter. The equation for prediction of PEFR in boys was calculated as (3.8 x height) + (10.6 x age) - 313.2 (p age) - 143.9 (p ... coefficient in this large sample. Among healthy children without previous asthma, earlier episodes of recurrent wheezing were reported in 8.8% and a significantly lower PEFR was found in this group....

  1. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review.

    Science.gov (United States)

    Ai, Z T; Melikov, A K

    2018-07-01

    This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. The effect of spherical hub-nose position on pressure drop in an oscillating water column system for wave energy conversion

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Z.; Ahmad, N.; Ghazilla, R.A.R.; Yap, H.J.; Ya, T.Y.T.; Passarella, R.; Hasanuddin, I.; Yunus, M. [Malaya Univ. (Malaysia). Centre for Product Design and Manufacturing; Sugiyono [Malaya Univ., (Malaysia). Centre for Product Design and Manufacturing; Gadjah Mada Univ. (Indonesia). Dept. of Mechanical and Industrial Engineering

    2009-07-01

    The use of renewable energy sources as an alternative to conventional fuels was discussed with particular reference to ocean wave energy and its potential to contribute to the energy requirements of coastal nations. Ocean wave energy has been harnessed and converted into electricity using processes and technologies that are environmentally sound. The oscillating water column (OWC) system is considered to be among the most promising technology for harnessing wave energy. This paper presented the results of a study that investigated the pressure drop in an OWC system and the effect of spherical hub-nose position in an annular duct. Computational fluid dynamics (CFD) analysis was used under steady flow conditions for several hub-nose positions to determine the characteristic of pressure drop. The study showed that the hub-nose position influenced the pressure drop in the OWC system. The highest value of the pressure drop in this study occurred when the hub-nose was at the position of 0.0 m relative to the end of the converging cone. The pressure drop decreased when the hub-nose position moved away from the end of converging cone. The lowest value occurred at the position of -0.5 m. It was concluded that despite the numerically small change in pressure drop, this phenomenon should be considered in the design process of the OWC system because of the operational condition of the system at low-pressure pneumatic power. The pressure drop actually reduces the amount of energy that will be converted by the air turbine. 9 refs., 2 tabs., 6 figs.

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Tomorrows Laboratory and Clinical Research We Fund CFTR Modulation Research We Fund CFTR Restoration Research We Fund ... Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow Us On ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis comes with many challenges, including medical, social, and financial. By learning more about how you ... Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials 101 What to Consider ...

  10. Airway Clearance Techniques (ACTs)

    Science.gov (United States)

    ... infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway ... Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... the daily lives of people with CF. CF Peer Connect Community Voice Help Shape CF Research IMPACT ... More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  13. Bilateral parotitis in a patient under continuous positive airway pressure treatment.

    Science.gov (United States)

    Abdullayev, Ruslan; Saral, Filiz Cosku; Kucukebe, Omer Burak; Sayiner, Hakan Sezgin; Bayraktar, Cem; Akgun, Sadik

    Many conditions such as bacterial and viral infectious diseases, mechanical obstruction due to air and calculi and drugs can cause parotitis. We present a case of unusual bilateral parotitis in a patient under non-invasive continuous positive airway pressure (CPAP) therapy for chronic obstructive pulmonary disease exacerbation in intensive care unit. A 36-year-old patient was admitted to intensive care unit with the diagnosis of chronic obstructive pulmonary disease exacerbation. Antibiotherapy, bronchodilator therapy and non-invasive positive pressure ventilation were applied as treatment regimen. Painless swellings developed on the 3rd day of admission on the right and a day after this on the left parotid glands. Amylase levels were increased and ultrasonographic evaluation revealed bilateral parotitis. No intervention was made and the therapy was continued. The patient was discharged on the 6th day with clinical improvement and regression of parotid swellings without any complications. Parotitis may have occurred after retrograde air flow in the Stensen duct during CPAP application. After the exclusion of possible viral and bacteriological etiologies and possible drug reactions we can focus on this diagnosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  14. The effect of lung deflation on the position of the pleura during subclavian vein cannulation in infants receiving mechanical ventilation: an ultrasound study.

    Science.gov (United States)

    Jang, Y-E; Lee, J-H; Park, Y-H; Byon, H-J; Kim, H-S; Kim, C-S; Kim, J-T

    2013-10-01

    We evaluated the effect of lung deflation on the relative position of the pleura compared with a reference line during supra- and infraclavicular approaches to the right subclavian vein. The reference line was drawn relative to the predicted pathway of the needle. The distances between the pleura and the reference line for supra- and infraclavicular approaches were measured during inspiration and expiration in 41 infants. Measurements were repeated with the application of 5 cmH2O positive end-expiratory pressure (PEEP) and in the Trendelenburg position. Lung deflation during the supraclavicular approach significantly decreased the volume of lung crossing the reference line by a median (IQR [range]) of 1.0 (0.6 to 1.3 [0.0 to 4.8]) mm, p deflation showed no change in the distance of the pleura from the reference line regardless of PEEP or patient position. We conclude that lung deflation moves the lung apex caudally and can reduce the potential risk of pneumothorax during a supraclavicular approach to the right subclavian vein in infants. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  15. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    Directory of Open Access Journals (Sweden)

    Moro M

    2016-07-01

    Full Text Available Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA, also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management.Methods: We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split night; n=306 two-night. Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI ≥5 during split PSG (SN-PSG versus full-night PSG (FN-PSG titrations.Results: CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients.Conclusion: Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the

  16. Continuous positive airway pressure (CPAP).

    Science.gov (United States)

    Sahni, R; Wung, J T

    1998-01-01

    Progress in neonatal intensive care is closely linked to improvements in the management of respiratory failure in small infants. This applies to the care of the preterm infants with immature lungs, and also to treatment of the preterm or full term infants with specific diseases that are associated with respiratory failure. Respiratory distress of the newborn continues to account for significant morbidity in the intensive care unit. The spectrum of disease ranges from mild distress to severe respiratory failure requiring varying degrees of support. The current modalities of ventilatory assistance range from the more benign continuous positive airway pressure (CPAP) to conventional mechanical ventilation, and on to high frequency ventilation. It is a reasonable supposition that the type of ventilatory assistance provided to these infants should be graded according to the severity of the disease. However, the principal objective in selecting the mode of respiratory support should be to use a modality which results in minimal volo- or barotrauma to the infant. The following detailed description on CPAP explains its physiological effects, delivery system, indications for use, application, maintenance, and associated complications. The equipment described is simple to use, has a greater cost benefit, and has a more universal application, which is of help to smaller units including those in the developing parts of the world. We have also included our institutional clinical experience of CPAP usage in very low birth weight infants from the periods before and after commercial availability of surfactant in the United States.

  17. Effects of brief smoking cessation education with expiratory carbon monoxide measurement on level of motivation to quit smoking.

    Science.gov (United States)

    Choi, Won-Young; Kim, Cheol-Hwan; Lee, Ok-Gyu

    2013-05-01

    Smoking rates among Korean adult males is still high despite multifaceted efforts to reduce it. In Korea, there have been several studies on the effectiveness of smoking cessation education for inpatients, health check-ups, and smoking cessation clinics. However, there haven't been any studies on the effectiveness of smoking cessation education conducted outside the hospital. This study investigated effectiveness of brief education on smoking cessation with an expiratory carbon monoxide (CO) measurement outside the hospital among adult male office-workers in Korea. From April 1st to May 10th, 2012, we conducted a controlled trial among 95 adult male office workers over the age of 19 who smoke outside, in a public place in Seoul by cluster sampling. For the education group, we provided smoking cessation education for about 5 to 10 minutes, measured the expiratory CO level, and made the subjects complete questionnaires, while only self-help materials on quitting smoking were given to the control group. After 4 weeks, we evaluated the change in the level of motivation or success to quit smoking in both groups via e-mail or mobile phone. In the education group, the level of motivation to quit smoking was improved significantly. A multiple logistic regression analysis showed that the odds ratio of improved motivation to quit smoking in the education group was 28.10 times higher than that of the control group. Brief education on smoking cessation with expiratory CO measurement conducted outside the hospital could enhance the level of motivation to quit smoking.

  18. Early predictors of success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

    Science.gov (United States)

    Bhattacharyya, D; Prasad, Bnbm; Tampi, P S; Ramprasad, R

    2011-10-01

    Non-invasive positive pressure ventilation (NIPPV) has emerged as a significant advancement in the management of acute hypercapnic respiratory failure. Patients with hypercapnic respiratory failure requiring ventilation therapy (respiratory rate [RR] of > 30 breaths per minutes, PaCO2 > 55 mmHg and arterial pH success group and these parameters continued to improve even after four and 24 hours of NIPPV treatment. Out of 24 (24%) patients who failed to respond, 13 (54%) needed endotracheal intubation within one hour. The failure group had higher baseline HR than the success group. Improvement in HR, RR, pH, and PCO2 one hour after putting the patient on NIPPV predicts success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

  19. Beat-by-beat analysis of cardiac output and blood pressure responses to short-term barostimulation in different body positions

    Science.gov (United States)

    Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.

    Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.

  20. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery

    NARCIS (Netherlands)

    Hemmes, S.N.T.; Severgnini, P.; Jaber, S.; Canet, J.; Wrigge, H.; Hiesmayr, M.; Tschernko, E.M.; Hollmann, M.W.; Binnekade, J.M.; Hedenstierna, G.; Putensen, C.; Gama de Abreu, M.; Pelosi, P.; Schultz, M.J.

    2011-01-01

    ABSTRACT: BACKGROUND: Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia > 2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure

  1. Current concepts of protective ventilation during general anaesthesia

    NARCIS (Netherlands)

    Serpa Neto, Ary; Schultz, Marcus J.; Slutsky, Arthur S.

    2015-01-01

    Mechanical ventilation with high tidal volumes (VT) has been common practice in operating theatres because this strategy recruits collapsed lung tissue and improves ventilation-perfusion mismatch, thus decreasing the need for high inspired oxygen concentrations. Positive end-expiratory pressure

  2. Protective ventilation reduces Pseudomonas aeruginosa growth in lung tissue in a porcine pneumonia model.

    Science.gov (United States)

    Sperber, Jesper; Nyberg, Axel; Lipcsey, Miklos; Melhus, Åsa; Larsson, Anders; Sjölin, Jan; Castegren, Markus

    2017-08-31

    Mechanical ventilation with positive end expiratory pressure and low tidal volume, i.e. protective ventilation, is recommended in patients with acute respiratory distress syndrome. However, the effect of protective ventilation on bacterial growth during early pneumonia in non-injured lungs is not extensively studied. The main objectives were to compare two different ventilator settings on Pseudomonas aeruginosa growth in lung tissue and the development of lung injury. A porcine model of severe pneumonia was used. The protective group (n = 10) had an end expiratory pressure of 10 cm H 2 O and a tidal volume of 6 ml x kg -1 . The control group (n = 10) had an end expiratory pressure of 5 cm H 2 O and a tidal volume of 10 ml x kg -1 . 10 11 colony forming units of Pseudomonas aeruginosa were inoculated intra-tracheally at baseline, after which the experiment continued for 6 h. Two animals from each group received only saline, and served as sham animals. Lung tissue samples from each animal were used for bacterial cultures and wet-to-dry weight ratio measurements. The protective group displayed lower numbers of Pseudomonas aeruginosa (p protective group was unchanged (p protective ventilation with lower tidal volume and higher end expiratory pressure has the potential to reduce the pulmonary bacterial burden and the development of lung injury.

  3. Visual evoked potentials show strong positive association with intracranial pressure in patients with cryptococcal meningitis

    Directory of Open Access Journals (Sweden)

    Marcelo Adriano da Cunha Silva Vieira

    2015-04-01

    Full Text Available Objective : To verify the relationship between intracranial pressure and flash visual evoked potentials (F-VEP in patients with cryptococcal meningitis. Method The sample included adults diagnosed with cryptococcal meningitis admitted at a reference hospital for infectious diseases. The patients were subjected to F-VEP tests shortly before lumbar puncture. The Pearson’s linear correlation coefficient was calculated and the linear regression analysis was performed. Results : Eighteen individuals were subjected to a total of 69 lumbar punctures preceded by F-VEP tests. At the first lumbar puncture performed in each patient, N2 latency exhibited a strong positive correlation with intracranial pressure (r = 0.83; CI = 0.60 - 0.94; p < 0.0001. The direction of this relationship was maintained in subsequent punctures. Conclusion : The intracranial pressure measured by spinal tap manometry showed strong positive association with the N2 latency F-VEP in patients with cryptococcal meningitis.

  4. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2011-03-01

    The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range.

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway ... Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  6. Response of Preterm Infants to 2 Noninvasive Ventilatory Support Systems: Nasal CPAP and Nasal Intermittent Positive-Pressure Ventilation.

    Science.gov (United States)

    Silveira, Carmen Salum Thomé; Leonardi, Kamila Maia; Melo, Ana Paula Carvalho Freire; Zaia, José Eduardo; Brunherotti, Marisa Afonso Andrade

    2015-12-01

    Noninvasive ventilation (NIV) in preterm infants is currently applied using intermittent positive pressure (2 positive-pressure levels) or in a conventional manner (one pressure level). However, there are no studies in the literature comparing the chances of failure of these NIV methods. The aim of this study was to evaluate the occurrence of failure of 2 noninvasive ventilatory support systems in preterm neonates over a period of 48 h. A randomized, prospective, clinical study was conducted on 80 newborns (gestational age CPAP and 40 infants with nasal intermittent positive-pressure ventilation (NIPPV). The occurrence of apnea, progression of respiratory distress, nose bleeding, and agitation was defined as ventilation failure. The need for intubation and re-intubation after failure was also observed. There were no significant differences in birth characteristics between groups. Ventilatory support failure was observed in 25 (62.5%) newborns treated with nasal CPAP and in 12 (30%) newborns treated with NIPPV, indicating an association between NIV failure and the absence of intermittent positive pressure (odds ratio [OR] 1.22, P CPAP failure. After failure, 25% (OR 0.33) of the newborns receiving nasal CPAP and 12.5% (OR 0.14) receiving NIPPV required invasive mechanical ventilation. Ventilatory support failure was significantly more frequent when nasal CPAP was used. Copyright © 2015 by Daedalus Enterprises.

  7. The bedding environment, sleep position, and frequent wheeze in childhood.

    Science.gov (United States)

    Ponsonby, Anne-Louise; Dwyer, Terence; Trevillian, Leigh; Kemp, Andrew; Cochrane, Jennifer; Couper, David; Carmichael, Allan

    2004-05-01

    Synthetic quilt use has been associated with increased childhood wheeze in previous studies. Our aim was to examine whether the adverse effect of synthetic quilt use on frequent wheeze differed by usual sleep position. A population-based cross-sectional study of 6378 (92% of those eligible) 7-year-olds in Tasmania, Australia, was conducted in 1995. Exercise-challenge lung function was obtained on a subset of 414 children from randomly selected schools. Child bedding including pillow and overbedding composition and usual sleep position by parental questionnaire. Frequent wheeze (>12 wheeze episodes over the past year), using the International Study of Asthma and Allergies in Childhood parental questionnaire, and baseline and postexercise forced expiratory volume in 1 second lung-function measures. Frequent wheeze (n = 117) was positively associated with synthetic quilts, synthetic pillows, electric blankets, and sleeping in a bottom bunk bed but did not vary by sleep position. In a nested case-control analysis, the association between synthetic quilt use and frequent wheeze differed by sleep position. Among children who slept supine, synthetic (versus feather) quilt use was associated with frequent wheeze (adjusted odds ratio: 2.37 [1.08, 5.23]). However, among nonsupine sleepers, overlying synthetic quilt use was not associated with frequent wheeze (adjusted odds ratio: 1.06 [0.60, 1.88]). This difference in quilt effect by sleep position was highly significant. Similarly, synthetic quilt use was associated with lower postexercise forced expiratory volume in 1 second measures among supine but not nonsupine sleeping children. An increasing focus on the bedding environment immediately adjacent to the nose and mouth is required for respiratory disorders provoked by bedding, such as child asthma characterized by frequent wheeze.

  8. Nasal continuous positive airways pressure immediately after extubation for preventing morbidity in preterm infants.

    Science.gov (United States)

    Davis, P G; Henderson-Smart, D J

    2003-01-01

    Preterm infants being extubated following a period of intermittent positive pressure ventilation via an endotracheal tube are at risk of developing respiratory failure as a result of apnea, respiratory acidosis and hypoxia. Nasal continuous positive airway pressure appears to stabilise the upper airway, improve lung function and reduce apnea and may therefore have a role in facilitating extubation in this population. In preterm infants having their endotracheal tube removed following a period of intermittent positive pressure ventilation (IPPV), does management with nasal continuous positive airways pressure (NCPAP) lead to an increased proportion remaining free of additional ventilatory support, compared to extubation directly to headbox oxygen? Searches were made of the Oxford Database of Perinatal Trials, MEDLINE up to November 2002, Cochrane Controlled Trials Register (The Cochrane Library, Issue 4, 2002), previous reviews including cross references, abstracts of conferences and symposia proceedings, expert informants and journal handsearching mainly in the English language. All trials utilising random or quasi-random patient allocation, in which NCPAP (delivered by any method) was compared with headbox oxygen for post-extubation care were included. Methodological quality was assessed independently by the two authors. Data were extracted independently by the two authors. Prespecified subgroup analysis to determine the impact of different levels of NCPAP, differences in duration of IPPV and use of aminophylline were also performed using the same package. Data were analysed using relative risk (RR), risk difference (RD) and number needed to treat (NNT). Nasal CPAP, when applied to preterm infants being extubated following IPPV, reduces the incidence of adverse clinical events (apnea, respiratory acidosis and increased oxygen requirements) indicating the need for additional ventilatory support [RR 0.62 (0.49, 0.77), RD -0.17 (-0.24,-0.10), NNT 6 (4,10)]. nasal

  9. A direct method for determining complete positive and negative capillary pressure curves for reservoir rock using the centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    Spinler, E.A.; Baldwin, B.A. [Phillips Petroleum Co., Bartlesville, OK (United States)

    1997-08-01

    A method is being developed for direct experimental determination of capillary pressure curves from saturation distributions produced during centrifuging fluids in a rock plug. A free water level is positioned along the length of the plugs to enable simultaneous determination of both positive and negative capillary pressures. Octadecane as the oil phase is solidified by temperature reduction while centrifuging to prevent fluid redistribution upon removal from the centrifuge. The water saturation is then measured via magnetic resonance imaging. The saturation profile within the plug and the calculation of pressures for each point of the saturation profile allows for a complete capillary pressure curve to be determined from one experiment. Centrifuging under oil with a free water level into a 100 percent water saturated plug results in the development of a primary drainage capillary pressure curve. Centrifuging similarly at an initial water saturation in the plug results in the development of an imbibition capillary pressure curve. Examples of these measurements are presented for Berea sandstone and chalk rocks.

  10. Effect of the radiofrequency volumetric tissue reduction of inferior turbinate on expiratory nasal sound frequency.

    Science.gov (United States)

    Seren, Erdal

    2009-01-01

    We sought to evaluate the short-term efficacy of radiofrequency volumetric tissue reduction (RFVTR) in treatment of inferior turbinate hypertrophy (TH) as measured by expiratory nasal sound spectra. In our study, we aimed to investigate the Odiosoft-rhino (OR) as a new diagnostic method to evaluate the nasal airflow of patients before and after RFVTR. In this study, we have analyzed and recorded the expiratory nasal sound in patients with inferior TH before and after RFVTR. This analysis includes the time expanded waveform, the spectral analysis with time averaged fast Fourier transform (FFT), and the waveform analysis of nasal sound. We found an increase in sound intensity at high frequency (Hf) in the sound analyses of the patients before RFVTR and a decrease in sound intensity at Hf was found in patients after RFVTR. This study indicates that RFVTR is an effective procedure to improve nasal airflow in the patients with nasal obstruction with inferior TH. We found significant decreases in the sound intensity level at Hf in the sound spectra after RFVTR. The OR results from the 2000- to 4000-Hz frequency (Hf) interval may be more useful in assessing patients with nasal obstruction than other frequency intervals. OR may be used as a noninvasive diagnostic tool to evaluate the nasal airflow.

  11. Respiratory system mechanics during laparoscopic cholecystectomy.

    Science.gov (United States)

    Rizzotti, L; Vassiliou, M; Amygdalou, A; Psarakis, Ch; Rasmussen, T R; Laopodis, V; Behrakis, P

    2002-04-01

    The influence of laparoscopic cholecystectomy (LC) on the mechanical properties of the respiratory system (RS) was examined using multiple regression analysis (MRA). Measurements of airway pressure (PaO) and flow (V') were obtained from 32 patients at four distinct stages of the LC procedure: 1) Immediately before the application of pneumoperitoneum (PP) at supine position, 2) 5 min after the induction of PP at Trendelenburg position, 3) 5 min after the patients position at reverse Trendelenburg, and 4) 5 min after the end ofthe surgical procedure with the patient again in supine position. Evaluated parameters were the RS elastance (Ers), resistance (Rrs), impedance (Zrs), the angle theta indicating the balance between the elastic and resistive components of the impedance, as well as the end-expiratory elastic recoil pressure (EEP). Ers and Zrs increased considerably during PP and remained elevated immediately after abolishing PP Rrs, on the contrary, returned to pre-operative levels right after the operation. Change of body position from Trendelenburg (T) to reverseTrendelenburg (rT) mainly induced a significant change in theta, thus indicating an increased dominance of the elastic component of Zrs on changing fromT to rT. There was no evidence of increased End-Expiratory Pressure during PP

  12. Impact of ultrasound probe pressure on uterine positional displacement in gynecologic cancer patients

    DEFF Research Database (Denmark)

    Baker, Mariwan; Juhler-Nøttrup, Trine; Behrens, Claus F.

    2014-01-01

    Aim: The aim of this study was to quantify the uterine positional displacement induced by ultrasound probe pressure on a phantom and address the daily uterine motion in a healthy volunteer. Materials & methods: The phantom mimics the female pelvic region. The incorporated organs were subjected to...

  13. Ambulatory blood pressure profiles in familial dysautonomia.

    Science.gov (United States)

    Goldberg, Lior; Bar-Aluma, Bat-El; Krauthammer, Alex; Efrati, Ori; Sharabi, Yehonatan

    2018-02-12

    Familial dysautonomia (FD) is a rare genetic disease that involves extreme blood pressure fluctuations secondary to afferent baroreflex failure. The diurnal blood pressure profile, including the average, variability, and day-night difference, may have implications for long-term end organ damage. The purpose of this study was to describe the circadian pattern of blood pressure in the FD population and relationships with renal and pulmonary function, use of medications, and overall disability. We analyzed 24-h ambulatory blood pressure monitoring recordings in 22 patients with FD. Information about medications, disease severity, renal function (estimated glomerular filtration, eGFR), pulmonary function (forced expiratory volume in 1 s, FEV1) and an index of blood pressure variability (standard deviation of systolic pressure) were analyzed. The mean (± SEM) 24-h blood pressure was 115 ± 5.6/72 ± 2.0 mmHg. The diurnal blood pressure variability was high (daytime systolic pressure standard deviation 22.4 ± 1.5 mmHg, nighttime 17.2 ± 1.6), with a high frequency of a non-dipping pattern (16 patients, 73%). eGFR, use of medications, FEV1, and disability scores were unrelated to the degree of blood pressure variability or to dipping status. This FD cohort had normal average 24-h blood pressure, fluctuating blood pressure, and a high frequency of non-dippers. Although there was evidence of renal dysfunction based on eGFR and proteinuria, the ABPM profile was unrelated to the measures of end organ dysfunction or to reported disability.

  14. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  15. Positioning of electrode plane systematically influences EIT imaging.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi

    2015-06-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

  16. High flow nasal cannula for respiratory support in preterm infants.

    LENUS (Irish Health Repository)

    Wilkinson, Dominic

    2011-01-01

    High flow nasal cannulae (HFNC) are small, thin, tapered cannulae used to deliver oxygen or blended oxygen and air at flow rates of > 1 L\\/min. HFNC can be used to provide high concentrations of oxygen and may deliver positive end-expiratory pressure.

  17. Neurally adjusted ventilatory assist decreases ventilator-induced lung injury and non-pulmonary organ dysfunction in rabbits with acute lung injury

    NARCIS (Netherlands)

    Brander, Lukas; Sinderby, Christer; Lecomte, François; Leong-Poi, Howard; Bell, David; Beck, Jennifer; Tsoporis, James N.; Vaschetto, Rosanna; Schultz, Marcus J.; Parker, Thomas G.; Villar, Jesús; Zhang, Haibo; Slutsky, Arthur S.

    2009-01-01

    OBJECTIVE: To determine if neurally adjusted ventilatory assist (NAVA) that delivers pressure in proportion to diaphragm electrical activity is as protective to acutely injured lungs (ALI) and non-pulmonary organs as volume controlled (VC), low tidal volume (Vt), high positive end-expiratory

  18. Effect of Pneumoperitoneum and Lateral Position on Oropharyngeal Seal Pressures of Proseal LMA in Laparoscopic Urological Procedures.

    Science.gov (United States)

    Rustagi, Preeti; Patkar, Geeta A; Ourasang, Anil Kumar; Tendolkar, Bharati A

    2017-02-01

    A sustained and effective oropharyngeal sealing with supraglottic airway is required to maintain the ventilation during laparoscopic surgery. Previous studies have observed the Oropharyngeal Seal Pressure (OSP) for Proseal Laryngeal Mask Airway (PLMA) after pneumoperitoneum in supine and trendelenburg position, where PLMA was found to be an effective airway device. This study was conducted with ProSeal LMA, for laparoscopic Urologic procedures done in lateral position. To measure OSP in supine and lateral position and to observe the effect of pneumoperitoneum in lateral position on OSP. Secondary objectives were to assess adequacy of ventilation and incidence of adverse events. A total number of 25 patients of American Society of Anaesthesiologists (ASA) physical status II and I were enrolled. After induction of anaesthesia using a standardized protocol, PLMA was inserted. Ryle's tube was inserted through drain tube. The position of PLMA was confirmed with ease of insertion of Ryle's tube and fibreoptic grading of vocal cords. Patients were then put in lateral position. The OSP was measured in supine position. This value was baseline comparison for OSP in lateral position and that after pneumoperitoneum. We assessed the efficacy of PLMA for ventilation, after carboperitoneum in lateral position (peak airway pressure, End Tidal Carbon dioxide (EtCO 2 ), SPO 2 ). Incidence of adverse effects (displacement of device, gastric insufflation, regurgitation, coughing, sore throat, blood on device, trauma) was also noted. The OSP was above Peak Airway Pressure (PAP) in supine (22.1±5.4 and 15.4±4.49cm of H 2 O) and lateral position (22.6±5.3 and 16.1±4.6). After pneumoperitoneum, which was in lateral position, there was statistically significant (p-value <0.05) increase in both PAP (19.96±4.015) and OSP (24.32±4.98, p-value 0.03). There was no intraoperative displacement of PLMA. There was no event of suboptimal oxygenation. EtCO 2 was always within normal limits

  19. Echocardiographic assessment of systolic pulmonary arterial pressure in HIV-positive patients.

    Directory of Open Access Journals (Sweden)

    Mehrnaz Rasoulinejad

    2014-11-01

    Full Text Available Pulmonary hypertension is rare but is one of the complications that occur due to HIV infection. Symptoms of HIV-associated pulmonary arterial hypertension are often non-specific but the main symptom of the disease is dyspnea. In this cross-sectional study, we measured systolic pulmonary arterial pressure (SPAP by echocardiographic methods among HIV-positive patients who received ART. This research is a descriptive, cross-sectional study of 170 HIV-positive patients that was conducted in Imam-Khomeini hospital, Tehran, Iran during 2011-2013. All patients regularly received antiretroviral therapy at least for recent 2 years. There were not any cardiopulmonary symptoms (cough, dyspnea, exertional fatigue and chest discomfort in these patients. All participants underwent echocardiography to estimate SPAP. The participants comprised 108 males (63.5% and 62 females (46.5%. The mean age of patients was 41 years old, and the mean duration of HIV infection was 5.5 years. The mean CD4 cell count was 401 cell/µl. The principal regimen of antiretroviral therapy included two nucleoside reverse transcriptase inhibitor (NRTI and one non-nucleoside reverse transcriptase inhibitor (NNRTI in the hospital. The mean of systolic pulmonary arterial pressure was 25 mmHg in the participants; 156 (93.4% of them had SPAP ≤ 30 mmHg (normal, six (3.6% had SPAP: 31-35 mmHg (borderline and five (3% had SPAP > 35 mmHg (pulmonary hypertension. Our results indicated a significant increase of pulmonary hypertension in asymptomatic HIV-positive patients that had no association with any other risk factor. Also, antiretroviral therapy was not a risk factor for pulmonary hypertension in this study.

  20. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  1. Effects of Modes, Obesity, and Body Position on Non-invasive Positive Pressure Ventilation Success in the Intensive Care Unit: A Randomized Controlled Study.

    Science.gov (United States)

    Türk, Murat; Aydoğdu, Müge; Gürsel, Gül

    2018-01-01

    Different outcomes and success rates of non-invasive positive pressure ventilation (NPPV) in patients with acute hypercapnic respiratory failure (AHRF) still pose a significant problem in intensive care units. Previous studies investigating different modes, body positioning, and obesity-associated hypoventilation in patients with chronic respiratory failure showed that these factors may affect ventilator mechanics to achieve a better minute ventilation. This study tried to compare pressure support (BiPAP-S) and average volume targeted pressure support (AVAPS-S) modes in patients with acute or acute-on-chronic hypercapnic respiratory failure. In addition, short-term effects of body position and obesity within both modes were analyzed. We conducted a randomized controlled study in a 7-bed intensive care unit. The course of blood gas analysis and differences in ventilation variables were compared between BiPAP-S (n=33) and AVAPS-S (n=29), and between semi-recumbent and lateral positions in both modes. No difference was found in the length of hospital stay and the course of PaCO2, pH, and HCO3 levels between the modes. There was a mean reduction of 5.7±4.1 mmHg in the PaCO2 levels in the AVAPS-S mode, and 2.7±2.3 mmHg in the BiPAP-S mode per session (ppositioning had no notable effect in both modes. Although the decrease in the PaCO2 levels in the AVAPS-S mode per session was remarkably high, the course was similar in both modes. Furthermore, obesity and body positioning had no prominent effect on the PaCO2 response and ventilator mechanics. Post hoc power analysis showed that the sample size was not adequate to detect a significant difference between the modes.

  2. Detecting Output Pressure Change of Positive-Displacement Pump by Phase Trajectory Method

    Directory of Open Access Journals (Sweden)

    Jerzy Stojek

    2010-06-01

    Full Text Available The monitoring of hydraulic system condition change during its exploitation ran its complex problem. The main task is to identifyearly phase damage of hydraulic system elements (pumps, valves, ect. in order to take decision which can avoid hydraulic system breakdown. This paper presents the possibility of phase trajectories use in detecting output pressure change of hydraulic system causedby positive-displacement pump wear.

  3. The impact of arm position and pulse pressure on the validation of a wrist-cuff blood pressure measurement device in a high risk population

    Directory of Open Access Journals (Sweden)

    Ali Reza Khoshdel

    2010-03-01

    Full Text Available Ali Reza Khoshdel1,2, Shane Carney2, Alastair Gillies21Faculty of Medicine, Aja University of Medical Science, Tehran, Iran; 2John Hunter Hospital, Faculty of Health, The University of Newcastle, Newcastle, NS W, AustraliaAbstract: Despite the increasing popularity of blood pressure (BP wrist monitors for self-BP measurement at home, device validation and the effect of arm position remains an issue. This study focused on the validation of the Omron HEM-609 wrist BP device, including an evaluation of the impact of arm position and pulse pressure on BP measurement validation. Fifty patients at high risk for cardiovascular disease were selected (age 65 ± 10 years. Each patient had two measurements with a mercury sphygmomanometer and three measurements with the wrist BP device (wrist at the heart level while the horizontal arm supported [HORIZONTAL], hand supported on the opposite shoulder [SHOULDER], and elbow placed on a desk [DESK], in random order. The achieved systolic BP (SBP and diastolic BP (DBP wrist-cuff readings were compared to the mercury device and the frequencies of the readings within 5, 10, and 15 mmHg of the gold standard were computed and compared with the British Hypertension Society (BHS and Association for the Advancement of Medical Instrumentation (AAMI protocols. The results showed while SBP readings with HORIZONTAL and SHOULDER positions were significantly different from the mercury device (mean difference = 7.1 and 13.3 mmHg, respectively; P < 0.05, the DESK position created the closest reading to mercury (mean difference = 3.8, P > 0.1. Approximately 71% of SBP readings with the DESK position were within ±10 mmHg, whereas it was 62.5% and 34% for HORIZONTAL and SHOULDER positions, respectively. Wrist DBP attained category D with BHS criteria with all three arm positions. Bland–Altman plots illustrated that the wrist monitor systematically underestimated SBP and DBP values. However a reading adjustment of 5 and 10 mm

  4. Device for positioning ultrasonic probes and/or television cameras on the outer surface of reactor pressure vessels

    International Nuclear Information System (INIS)

    Zipser, R.; Dose, G.F.

    1977-01-01

    The device makes possible periodical in-service inspections of welding seams and material of a reactor pressure vessel without local human presence. A 'support ring' encloses the pressure vessel in a horizontal plane with free space. It is vertically moved up and down in the space between pressure vessel and thermal shield by means of tackles. At a control desk placed in a protected area its movement is controlled and its vertical position is indicated. A 'rotating track' with its own drive is rotating remote-controlled on the 'support ring'. By a combination of the vertical with the rotating movement, an ultrasonic probe placed removably on the 'rotating hack', or a television camera will be brought to any position on the cylindrical circumference of the pressure vessel. Special devices extend the radius of action, in upward direction for inspecting the welding seams of the coolant nozzles, and in downward direction for the inspection of welds on the hemispherical bottom of the pressure vessel or on the outlet pipe nozzle placed there. The device remains installed during reactor operation, but is moved down to the lower horizontal surface of the thermal shield. Parts which are sensible to radiation like probes or television cameras and special devices will then be removed respectively mounted before beginning an inspection compaign. This position may be reached by the lower access in the biological shield and through an opening in the horizontal surface of the thermal shield. (HP) [de

  5. Lung-protective perioperative mechanical ventilation

    NARCIS (Netherlands)

    Hemmes, S.N.T.

    2015-01-01

    Intraoperative ventilation has the potential to cause lung injury and possibly increase risk of pulmonary complications after surgery. Use of large tidal volumes could cause overdistension of lung tissue, which can be aggravated by too high levels of positive end-expiratory pressure (PEEP). Too low

  6. Is aerobic workload positively related to ambulatory blood pressure?

    DEFF Research Database (Denmark)

    Korshøj, Mette; Clays, Els; Lidegaard, Mark

    2016-01-01

    workload and ambulatory blood pressure (ABP) are lacking. The aim was to explore the relationship between objectively measured relative aerobic workload and ABP. METHODS: A total of 116 cleaners aged 18-65 years were included after informed consent was obtained. A portable device (Spacelabs 90217......) was mounted for 24-h measurements of ABP, and an Actiheart was mounted for 24-h heart rate measurements to calculate relative aerobic workload as percentage of relative heart rate reserve. A repeated-measure multi-adjusted mixed model was applied for analysis. RESULTS: A fully adjusted mixed model...... of measurements throughout the day showed significant positive relations (p ABP and 0.30 ± 0.04 mmHg (95 % CI 0.22-0.38 mmHg) in diastolic ABP. Correlations between...

  7. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    Science.gov (United States)

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  8. [Reduction of pressure sores during prone positioning of ventilated intensive care patients by the prone-head support system: a pilot study].

    Science.gov (United States)

    Prebio, Michael; Katz-Papatheophilou, Elfriede; Heindl, Werner; Gelbmann, Herbert; Burghuber, Otto C

    2005-02-01

    Prone positioning in patients with adult respiratory distress syndrome is a well-known method to improve oxygenation. The aim of our study was to evaluate a new device for prone positioning, the prone-head support system (PHS system), with regard to reduction of cutaneous pressure sores. In a pilot study we randomized 8 patients with ARDS in two groups: 180 degrees standard prone positioning (group without mask) and prone positioning with the PHS system (group with mask). The PHS system consists of a facemask support, which is connected to an adapted air suspension bed. The patients of both groups were intermittently proned for several days. We evaluated the pressure sores on head and neck before turning the patients prone for the first time and after each period of prone positioning. We documented the quantity, the size, the type and the localization of the pressure sores. There was no significant difference in the mean duration of prone positioning (27.1+/-14.7 hours in the group with mask versus 24.5+/-18.7 h in the group without mask). In the group with mask there were 1.5+/-0.8 new pressure sores by each proning, whereas in the group without mask there were 2.37+/-1.6 new pressure sores, which was lower, but not significantly. The overall area of pressure sores (798 mm2 versus 3184 mm2, p=0.004), the area of pressure sores per patient (199.5+/-104.7 mm2 versus 796+/-478 mm2, p=0.03) and the increase of the area of pressure sores per proning (79.8+/-52.0 mm2 versus 398.0+/-214.3 mm2, p=0.004) were significantly lower in the group with mask in comparison to the group without mask. The lips were the most effected localization in both groups. The pressure sores in the group with mask were less severe and showed a homogenous distribution in comparison to the group without mask. Blisters dominated in the group with mask in comparison to erosions, necrosis and ulcers in the group without mask. The PHS system with its face mask is able to reduce the extent and the

  9. Choking under Pressure: When an Additional Positive Stereotype Affects Performance for Domain Identified Male Mathematics Students

    Science.gov (United States)

    Rosenthal, Harriet E. S.; Crisp, Richard J.

    2007-01-01

    This research aimed to establish if the presentation of two positive stereotypes would result in choking under pressure for identified male mathematics students. Seventy-five 16 year old men, who had just commenced their AS-level study, were either made aware of their gender group membership (single positive stereotype), their school group…

  10. Randomized trial of prongs or mask for nasal continuous positive airway pressure in preterm infants.

    LENUS (Irish Health Repository)

    Kieran, Emily A

    2012-11-01

    To determine whether nasal continuous positive airway pressure (NCPAP) given with nasal prongs compared with nasal mask reduces the rate of intubation and mechanical ventilation in preterm infants within 72 hours of starting therapy.

  11. Reduced local immune response with continuous positive airway pressure during one-lung ventilation for oesophagectomy

    NARCIS (Netherlands)

    Verhage, R. J. J.; Boone, J.; Rijkers, G. T.; Cromheecke, G. J.; Kroese, A. C.; Weijs, T. J.; Borel Rinkes, I. H. M.; van Hillegersberg, R.

    2014-01-01

    Background. Transthoracic oesophagectomy requires prolonged one-lung ventilation causing systemic and local inflammatory responses. Application of continuous positive airway pressure (CPAP) to the collapsed lung potentially reduces pulmonary damage, hypoxia, and consequent inflammation. This

  12. Positioning of electrode plane systematically influences EIT imaging

    International Nuclear Information System (INIS)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Möller, Knut; Zhao, Zhanqi; Müller-Lisse, Ullrich

    2015-01-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔI_E_R_V/ERV, ΔI_V_T/VT and ΔI_I_R_V/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔI_E_R_V/ERV ratio in all subjects was significantly higher than the normalized ΔI_I_R_V/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions. (paper)

  13. Accuracy of automatic tube compensation in new-generation mechanical ventilators.

    Science.gov (United States)

    Elsasser, Serge; Guttmann, Josef; Stocker, Reto; Mols, Georg; Priebe, Hans-Joachim; Haberthür, Christoph

    2003-11-01

    To compare performance of flow-adapted compensation of endotracheal tube resistance (automatic tube compensation, ATC) between the original ATC system and ATC systems incorporated in commercially available ventilators. Bench study. University research laboratory. The original ATC system, Dräger Evita 2 prototype, Dräger Evita 4, Puritan-Bennett 840. The four ventilators under investigation were alternatively connected via different sized endotracheal tubes and an artificial trachea to an active lung model. Test conditions consisted of two ventilatory modes (ATC vs. continuous positive airway pressure), three different sized endotracheal tubes (inner diameter 7.0, 8.0, and 9.0 mm), two ventilatory rates (15/min and 30/min), and four levels of positive end-expiratory pressure (0, 5, 10, and 15 cm H2O). Performance of tube compensation was assessed by the amount of tube-related (additional) work of breathing (WOBadd), which was calculated on the basis of pressure gradient across the endotracheal tube. Compared with continuous positive airway pressure, ATC reduced inspiratory WOBadd by 58%, 68%, 50%, and 97% when using the Evita 4, the Evita 2 prototype, the Puritan-Bennett 840, and the original ATC system, respectively. Depending on endotracheal tube diameter and ventilatory pattern, inspiratory WOBadd was 0.12-5.2 J/L with the original ATC system, 1.5-28.9 J/L with the Puritan-Bennett 840, 10.4-21.0 J/L with the Evita 2 prototype, and 10.1-36.1 J/L with the Evita 4 (difference between each ventilator at identical test situations, p ventilator (p <.025). Flow-adapted tube compensation by the original ATC system significantly reduced tube-related inspiratory and expiratory work of breathing. The commercially available ATC modes investigated here may be adequate for inspiratory but probably not for expiratory tube compensation.

  14. The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children.

    Science.gov (United States)

    Gregson, Rachael K; Shannon, Harriet; Stocks, Janet; Cole, Tim J; Peters, Mark J; Main, Eleanor

    2012-03-01

    This study aimed to quantify the specific effects of manual lung inflations with chest compression-vibrations, commonly used to assist airway clearance in ventilated patients. The hypothesis was that force applied during the compressions made a significant additional contribution to increases in peak expiratory flow and expiratory to inspiratory flow ratio over and above that resulting from accompanying increases in inflation volume. Prospective observational study. Cardiac and general pediatric intensive care. Sedated, fully ventilated children. Customized force-sensing mats and a commercial respiratory monitor recorded force and respiration during physiotherapy. Percentage changes in peak expiratory flow, peak expiratory to inspiratory flow ratios, inflation volume, and peak inflation pressure between baseline and manual inflations with and without compression-vibrations were calculated. Analysis of covariance determined the relative contribution of changes in pressure, volume, and force to influence changes in peak expiratory flow and peak expiratory to inspiratory flow ratio. Data from 105 children were analyzed (median age, 1.3 yrs; range, 1 wk to 15.9 yrs). Force during compressions ranged from 15 to 179 N (median, 46 N). Peak expiratory flow increased on average by 76% during compressions compared with baseline ventilation. Increases in peak expiratory flow were significantly related to increases in inflation volume, peak inflation pressure, and force with peak expiratory flow increasing by, on average, 4% for every 10% increase in inflation volume (p children.

  15. Understanding the use of continuous oscillating positive airway pressure (bubble CPAP) to treat neonatal respiratory disease: an engineering approach.

    Science.gov (United States)

    Manilal-Reddy, P I; Al-Jumaily, A M

    2009-01-01

    A continuous oscillatory positive airway pressure with pressure oscillations incidental to the mean airway pressure (bubble CPAP) is defined as a modified form of traditional continuous positive airway pressure (CPAP) delivery where pressure oscillations in addition to CPAP are administered to neonates with lung diseases. The mechanical effect of the pressure oscillations on lung performance is investigated by formulating mathematical models of a typical bubble CPAP device and a simple representation of a neonatal respiratory system. Preliminary results of the respiratory system's mechanical response suggest that bubble CPAP may improve lung performance by minimizing the respiratory system impedance and that the resonant frequency of the respiratory system may be a controlling factor. Additional steps in terms of clinical trials and a more complex respiratory system model are required to gain a deeper insight into the mechanical receptiveness of the respiratory system to pressure oscillations. However, the current results are promising in that they offer a deeper insight into the trends of variations that can be expected in future extended models as well as the model philosophies that need to be adopted to produce results that are compatible with experimental verification.

  16. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    Science.gov (United States)

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  17. Single-Lung Transplant Results in Position Dependent Changes in Regional Ventilation: An Observational Case Series Using Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Kollengode Ramanathan

    2016-01-01

    Full Text Available Background. Lung transplantation is the optimal treatment for end stage lung disease. Donor shortage necessitates single-lung transplants (SLT, yet minimal data exists regarding regional ventilation in diseased versus transplanted lung measured by Electrical Impedance Tomography (EIT. Method. We aimed to determine regional ventilation in six SLT outpatients using EIT. We assessed end expiratory volume and tidal volumes. End expiratory lung impedance (EELI and Global Tidal Variation of Impedance were assessed in supine, right lateral, left lateral, sitting, and standing positions in transplanted and diseased lungs. A mixed model with random intercept per subject was used for statistical analysis. Results. EELI was significantly altered between diseased and transplanted lungs whilst lying on right and left side. One patient demonstrated pendelluft between lungs and was therefore excluded for further comparison of tidal variation. Tidal variation was significantly higher in the transplanted lung for the remaining five patients in all positions, except when lying on the right side. Conclusion. Ventilation to transplanted lung is better than diseased lung, especially in lateral positions. Positioning in patients with active unilateral lung pathologies will be implicated. This is the first study demonstrating changes in regional ventilation, associated with changes of position between transplanted and diseased lung.

  18. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    OpenAIRE

    Bianchi, Matt; Gannon,Karen; Lovell,Kathy; Merlino,Margaret; Mojica,James; Moro,Marilyn

    2016-01-01

    Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not w...

  19. Body Composition Response to Lower Body Positive Pressure Training in Obese Children

    OpenAIRE

    Basant H. El-Refay; Nabeel T. Faiad

    2014-01-01

    Background: The high prevalence of obesity in Egypt has a great impact on the health care system, economic and social situation. Evidence suggests that even a moderate amount of weight loss can be useful. Aim of the study: To analyze the effects of lower body positive pressure supported treadmill training, conducted with hypocaloric diet, on body composition of obese children. Methods: Thirty children aged between 8 and 14 years, were randomly assigned into two groups: intervention group (15 ...

  20. Pressure support ventilation vs Continuous positive airway pressure for treating of acute cardiogenic pulmonary edema: A pilot study.

    Science.gov (United States)

    Pagano, Antonio; Numis, Fabio G; Rosato, Valerio; Russo, Teresa; Porta, Giovanni; Bosso, Giorgio; Serra, Claudia; Masarone, Mario; Visone, Giuseppe; Paladino, Fiorella

    2018-04-24

    Non-invasive ventilation is usually adopted as a support to medical therapy in patients with acute pulmonary edema, but which modality between Pressure Support Ventilation (PSV) and Continuous Positive Airway Pressure (CPAP) has better favourable effects is not been yet well known. Aim of this observational study was to provide data on these different non-invasive ventilation modalities in the management of acute cardiogenic pulmonary edema. One-hundred-fifty-three patients consecutively admitted to the Emergency Room of two different Center were enrolled and randomly assigned to CPAP or PSV. Data relative to mortality, need of endotracheal intubation, sequential blood gas analysis were compared. Furthermore, there were no significant differences regarding mortality in the two groups, but patients treated with PSV had a significant lower rate of endotracheal intubation and a higher improvement of blood gas analyses parameters. In conclusion, our data support only a slight advantage in favour to PSV versus CPAP. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Positive Rates and Factors Associated with Abnormal Lung Function of Greenhouse Workers in China: A Cross-Sectional Study.

    Science.gov (United States)

    Zhu, Xiaojun; Gao, Panjun; Gu, Yishuo; Xiao, Pei; Liu, Mengxuan; Chen, Juan; Cen, Yacai; Ma, Wenjun; Li, Tao

    2017-08-24

    Since the number of greenhouse workers are increasing in China, this observational cross-sectional study was designed to evaluate lung function and discuss the potential risk factors, to provide evidence in the surveillance of greenhouse workers' health. 678 greenhouse workers in Gansu Province, China were enrolled. A questionnaire which included demographic and occupational information was used. Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 s (FEV₁), and FEV₁:FVC ratios (FEV₁/FVC), maximal expiratory flow after 50% of the FVC has not been exhaled (MEF 50 ), maximal expiratory flow after 25% of the FVC has not been exhaled (MEF 25 ) and maximal mid-expiratory flow curve (MMEF) were measured as lung function indicators. The mean values and standard deviations (SDs) of VC% predicted, FVC% predicted, FEV₁% predicted and FEV₁/FVC ratio were 106.07 ± 13.36, 107.60 ± 13.95, 97.19 ± 14.80 and 89.76 ± 10.78 respectively. The positive rates of above four and abnormal lung ventilation function were 2.9%, 2.8%, 11.2%, 4.6% and 6.5% respectively. Gender, age, BMI and number of greenhouses owned were influence factors of lung ventilation function ( p greenhouses owned were influence factors for small airway function ( p greenhouse might influence lung function of the workers. Small airway function indicators could be used as priority indicators for the surveillance of greenhouse workers' health.

  2. Pressure-induced positive electrical resistivity coefficient in Ni-Nb-Zr-H glassy alloy

    Science.gov (United States)

    Fukuhara, M.; Gangli, C.; Matsubayashi, K.; Uwatoko, Y.

    2012-06-01

    Measurements under hydrostatic pressure of the electrical resistivity of (Ni0.36Nb0.24Zr0.40)100-xHx (x = 9.8, 11.5, and 14) glassy alloys have been made in the range of 0-8 GPa and 0.5-300 K. The resistivity of the (Ni0.36Nb0.24Zr0.40)86H14 alloy changed its sign from negative to positive under application of 2-8 GPa in the temperature range of 300-22 K, coming from electron-phonon interaction in the cluster structure under pressure, accompanied by deformation of the clusters. In temperature region below 22 K, the resistivity showed negative thermal coefficient resistance by Debye-Waller factor contribution, and superconductivity was observed at 1.5 K.

  3. Related factors to semi-recumbent position compliance and pressure ulcers in patients with invasive mechanical ventilation: An observational study (CAPCRI study).

    Science.gov (United States)

    Llaurado-Serra, Mireia; Ulldemolins, Marta; Fernandez-Ballart, Joan; Guell-Baro, Rosa; Valentí-Trulls, Teresa; Calpe-Damians, Neus; Piñol-Tena, Angels; Pi-Guerrero, Mercedes; Paños-Espinosa, Cristina; Sandiumenge, Alberto; Jimenez-Herrera, María F

    2016-09-01

    Semi-recumbent position is recommended to prevent ventilator-associated pneumonia. Its implementation, however, is below optimal. We aimed to assess real semi-recumbent position compliance and the degree of head-of-bed elevation in Spanish intensive care units, along with factors determining compliance and head-of-bed elevation and their relationship with the development of pressure ulcers. Finally, we investigated the impact that might have the diagnosis of pressure ulcers in the attitude toward head-of-bed elevation. We performed a prospective, multicenter, observational study in 6 intensive care units. Inclusion criteria were patients ≥18 years old and expected to remain under mechanical ventilator for ≥48h. Exclusion criteria were patients with contraindications for semi-recumbent position from admission, mechanical ventilation during the previous 7 days and prehospital intubation. Head-of-bed elevation was measured 3 times/day for a maximum of 28 days using the BOSCH GLM80(®) device. The variables collected related to patient admission, risk of pressure ulcers and the measurements themselves. Bivariate and multivariate analyses were carried out using multiple binary logistic regression and linear regression as appropriate. Statistical significance was set at preplacement therapy, nursing shift, open abdomen, abdominal vacuum therapy and agitation. Twenty-five patients (9.1%) developed a total of 34 pressure ulcers. The diagnosis of pressure ulcers did not affect the head-of-bed elevation. In the multivariate analysis, head-of-bed elevation was not identified as an independent risk factor for pressure ulcers. Semi-recumbent position compliance is below optimal despite the fact that it seems achievable most of the time. Factors that affect semi-recumbent position include the particular intensive care unit, abdominal conditions, renal replacement therapy, agitation and bed type. Head-of-bed elevation was not related to the risk of pressure ulcers. Efforts

  4. Spontaneous breathing during lung-protective ventilation in an experimental acute lung injury model: high transpulmonary pressure associated with strong spontaneous breathing effort may worsen lung injury.

    Science.gov (United States)

    Yoshida, Takeshi; Uchiyama, Akinori; Matsuura, Nariaki; Mashimo, Takashi; Fujino, Yuji

    2012-05-01

    We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups. Even when plateau pressure is limited to mechanical ventilation, transpulmonary pressure and tidal volume should be strictly controlled to prevent further lung injury.

  5. "THE EVALUATION OF THE POSSIBLE EFFECT OF POSITIVE END EXPIRATORY PRESSURE (PEEP) ON PHARMACOKINETICS OF PHENYTOIN IN PATIENTS WITH ACUTE BRAIN INJURY UNDER MECHANICAL VENTILATION."

    OpenAIRE

    "Elham Hadidi; Mojtaba Mojtahedzadeh; Mohammad Reza Rouini; Behzad Eftekhar; Mohammad Abdollahi; Atabak Najafi; Mohammad R. Khajavi; Saeed Rezaee; Reza Ghaffari; Minoo Afshar"

    2005-01-01

    Positive ventilation has shown to have an influence on pharmacokinetic and disposition of some drugs.Beacause phenytoin with a narrow therapautic range, is the most commonly used drug for prophylaxis and treatment of early seizures after acute brain injuries, in the present study the effect of short term PEEP (5-10 cm H2O for at least 8 hours) on phenytoin serum concentration and pharmacokinetic parameters such as Vmax and clearance in brain injured patients under mechanical ventilation was e...

  6. Early warning and prevention of pneumonia in acute leukemia by patient education, spirometry, and positive expiratory pressure

    DEFF Research Database (Denmark)

    Møller, Tom; Moser, Claus; Adamsen, Lis

    2016-01-01

    Long-lasting neutropenia associated with acute myeloid leukemia (AML) and its treatment gives rise to a high risk of pneumonia. The use of broad-spectrum antibiotic prophylaxis during outpatient management has not completely protected patients against admission due to infections and neutropenic...... in their continuous daily measurement of FEV1 and use of PEP. Daily measures of FEV1 may be an important early warning tool for assessment of pulmonary deterioration during critical phases of neutropenia. We suggest that strategic patient education in the use of spirometry and PEP should be part of standard of care...

  7. [Effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection].

    Science.gov (United States)

    Fan, Yuan-hua; Liu, Yuan-fei; Zhu, Hua-yong; Zhang, Min

    2012-02-01

    To evaluate effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection, based on the protective pulmonary ventilation strategy. Ninety-seven cases with severe pulmonary infection admitted to intensive care unit (ICU) of Ganzhou City People's Hospital undergoing mechanical ventilation were involved. Volume controlled ventilation mode with small tidal volume (8 ml/kg) and positive end-expiratory pressure (PEEP) of 6 cm H(2)O [1 cm H(2)O = 0.098 kPa] was conducted. Each patient underwent recruitment maneuver in supine position and then in prone position [PEEP 20 cm H(2)O+pressure control (PC) 20 cm H(2)O]. Heart rate (HR), mean arterial pressure (MAP), pulse oxygen saturation [SpO(2)] and blood gas analysis data were recorded before and after recruitment maneuver in either position. A double-lumen venous catheter was inserted into internal jugular vein or subclavian vein, and a pulse index contour cardiac output (PiCCO) catheter was introduced into femoral artery. Cardiac index (CI), stroke volume index (SVI), systemic vascular resistance index (SVRI), intra-thoracic blood volume index (ITBVI), extra vascular lung water index (EVLWI), global end-diastolic volume index (GEDVI), global ejection fraction (GEF), stroke volume variation (SVV) and central vein pressure (CVP) were monitored. (1) Compared with data before recruitment maneuver, there were no significant differences in HR and MAP after supine position and prone position recruitment maneuver, but significant differences in SpO(2) were found between before and after recruitment maneuver when patients' position was changed (supine position: 0.954 ± 0.032 vs. 0.917 ± 0.025, P recruitment maneuver (P recruitment maneuver, CI [L×min(-1)×m(-2)], SVI (ml/m(2)), GEDVI (ml/m(2)) and GEF were decreased significantly during recruitment maneuver (supine position: CI 3.2 ± 0.4 vs. 3.8 ± 0.6, SVI 32.4 ± 5.6 vs. 38.8 ± 6.5, GEDVI 689 ± 44 vs. 766 ± 32, GEF 0.267 ± 0

  8. Chest compression with a higher level of pressure support ventilation: effects on secretion removal, hemodynamics, and respiratory mechanics in patients on mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Wagner da Silva Naue

    2014-01-01

    Full Text Available OBJECTIVE: To determine the efficacy of chest compression accompanied by a 10-cmH2O increase in baseline inspiratory pressure on pressure support ventilation, in comparison with that of aspiration alone, in removing secretions, normalizing hemodynamics, and improving respiratory mechanics in patients on mechanical ventilation. METHODS: This was a randomized crossover clinical trial involving patients on mechanical ventilation for more than 48 h in the ICU of the Porto Alegre Hospital de Clínicas, in the city of Porto Alegre, Brazil. Patients were randomized to receive aspiration alone (control group or compression accompanied by a 10-cmH2O increase in baseline inspiratory pressure on pressure support ventilation (intervention group. We measured hemodynamic parameters, respiratory mechanics parameters, and the amount of secretions collected. RESULTS: We included 34 patients. The mean age was 64.2 ± 14.6 years. In comparison with the control group, the intervention group showed a higher median amount of secretions collected (1.9 g vs. 2.3 g; p = 0.004, a greater increase in mean expiratory tidal volume (16 ± 69 mL vs. 56 ± 69 mL; p = 0.018, and a greater increase in mean dynamic compliance (0.1 ± 4.9 cmH2O vs. 2.8 ± 4.5 cmH2O; p = 0.005. CONCLUSIONS: In this sample, chest compression accompanied by an increase in pressure support significantly increased the amount of secretions removed, the expiratory tidal volume, and dynamic compliance. (ClinicalTrials.gov Identifier:NCT01155648 [http://www.clinicaltrials.gov/

  9. Positive pressure ventilation and cranial volume in newborn infants.

    OpenAIRE

    Milligan, D W

    1981-01-01

    The relationship between changes in airways pressure, pleural pressure, and cranial volume was studied in a group of sick newborn infants requiring ventilatory assistance. Cranial volume increased appreciably only when lung compliance was such that more than 20% of the applied airways pressure was transmitted to the pleural space, or if the absolute pleural pressure was greater than 4 cmH2O above atmospheric pressure. The findings stress the need for more-critical monitoring during periods of...

  10. Avaliação da função pulmonar de recém-nascidos com síndrome do desconforto respiratório em diferentes pressões finais expiratórias positivas Assessment of pulmonary function of preterm newborn infants with respiratory distress syndrome at different positive end expiratory pressure levels

    Directory of Open Access Journals (Sweden)

    Luiz C.T. Consolo

    2002-09-01

    Full Text Available RESUMO\tABSTRACT \t Objetivo: verificar as alterações da função pulmonar: complacência dinâmica (Cdyn, volume corrente inspiratório (V Tinsp, pressão arterial de dióxido de carbono (PaCO2, em recém-nascidos pré-termo com síndrome do desconforto respiratório. Pacientes e Métodos: estudo de caso controle, incluindo 11 pré-termos com idade gestacional Objective: to verify the alterations of pulmonary function in preterm newborn infants with respiratory distress syndrome (RDS. The parameters analyzed were Dynamic Compliance (Cdyn, Inspiratory Tidal Volume (TVinsp, partial arterial pressure of carbon dioxide (PaCO2. Methods: eleven preterm newborn infants, with gestational age < 35 weeks, and birth weight < 2.500 g, were include in a control case study. All infants presented RDS and were treated with 120 mg/Kg of porcine surfactant. The initial positive end expiratory pressure (PEEP was 3 cm H2O. A pneumotachograph with a graphical monitor was used to assess the pulmonary function. After each increase in the PEEP (4 and 6 cm H2O, there was an interval of 20 minutes before measuring the arterial data of pulmonary function and arterial gases. Results: there were three males and eight females (1:2,7 among the infants with RDS. The mean gestational age was 30.78. 2.05 weeks, ranging from 26 to 34 weeks. The increase in the PEEP from 3 to 6 cm H2O caused significant decrease in the TVinsp (6.46 ±3.43 to 4.20 ±2.35, P=0.0262. With the increase in the PEEP from 4 to 6 cm H2O, there was also a decrease in the TVinsp (5.98.± 3.33 to 4.20.± 2.35, (P=0.0044. Regarding the Cdyn, when there was an increase in the PEEP from 3 to 6 cm H2O, the reduction was statistically significant (0.58.± 0.27 to 0.46± 0.25, P=0.0408 and from 4 to 6 cm H2O, the reduction in the Cdyn was also important (0.77± 0.27 to 0.46± 0.25, (P=0.0164. Increases in the PEEP from 4 to 6 cm H2O caused increases in the PaCO2 (52.81± 15.49 to 64.90± 12.69, (P= 0,0141. A

  11. Two Methods for Turning and Positioning and the Effect on Pressure Ulcer Development: A Comparison Cohort Study.

    Science.gov (United States)

    Powers, Jan

    2016-01-01

    We evaluated 2 methods for patient positioning on the development of pressure ulcers; specifically, standard of care (SOC) using pillows versus a patient positioning system (PPS). The study also compared turning effectiveness as well as nursing resources related to patient positioning and nursing injuries. A nonrandomized comparison design was used for the study. Sixty patients from a trauma/neurointensive care unit were included in the study. Patients were randomly assigned to 1 of 2 teams per standard bed placement practices at the institution. Patients were identified for enrollment in the study if they were immobile and mechanically ventilated with anticipation of 3 days or more on mechanical ventilation. Patients were excluded if they had a preexisting pressure ulcer. Patients were evaluated daily for the presence of pressure ulcers. Data were collected on the number of personnel required to turn patients. Once completed, the angle of the turn was measured. The occupational health database was reviewed to determine nurse injuries. The final sample size was 59 (SOC = 29; PPS = 30); there were no statistical differences between groups for age (P = .10), body mass index (P = .65), gender (P = .43), Braden Scale score (P = .46), or mobility score (P = .10). There was a statistically significant difference in the number of hospital-acquired pressure ulcers between turning methods (6 in the SOC group vs 1 in the PPS group; P = .042). The number of nurses needed for the SOC method was significantly higher than the PPS (P ≤ 0.001). The average turn angle achieved using the PPS was 31.03°, while the average turn angle achieved using SOC was 22.39°. The difference in turn angle from initial turn to 1 hour after turning in the SOC group was statistically significant (P patients to prevent development of pressure ulcers.

  12. Correlation between spirometry values and pulmonary artery pressure in young healthy subjects.

    Science.gov (United States)

    Grossman, Alon; Benderly, Michal; Prokupetz, Alex; Gordon, Barak; Kalter-Leibovici, Ofra

    2014-03-01

    Pulmonary hypertension is frequently associated with parenchymal lung disease. We evaluated the association between spirometry values and pulmonary artery systolic pressure (PASP) in young subjects without lung disease : We studied applicants to the Israeli Air Force, who undergo routine evaluation that includes resting spirometry and echocardiography. Applicants with overt lung disease were excluded. All echocardiographic studies performed in the years 1994 through 2010 (n = 6,598) were screened, and files that included PASP and spirometry values were analyzed for the association between PASP and FVC, FEV1, FEV1/FVC, peak expiratory flow, and forced expiratory flow during the middle half of the FVC maneuver. Of the 647 air force applicants who underwent echocardiography in which PASP was measurable and had spirometry data, 607 (94%) were male, and their average age was 18.16 ± 0.73 years. Mean PASP was 26.4 ± 5.2 mm Hg (range 10-41 mm Hg). None of the spirometry values significantly correlated with PASP. PASP in young healthy subjects is not significantly associated with spirometry values. Lung mechanics probably do not contribute significantly to PASP in this population.

  13. Comparison of nasal continuous positive airway pressure delivered by seven ventilators using simulated neonatal breathing.

    Science.gov (United States)

    Drevhammar, Thomas; Nilsson, Kjell; Zetterström, Henrik; Jonsson, Baldvin

    2013-05-01

    Nasal continuous positive airway pressure (NCPAP) is an established treatment for respiratory distress in neonates. Most modern ventilators are able to provide NCPAP. There have been no large studies examining the properties of NCPAP delivered by ventilators. The aim of this study was to compare pressure stability and imposed work of breathing (iWOB) for NCPAP delivered by ventilators using simulated neonatal breathing. Experimental in vitro study. Research laboratory in Sweden. None. Neonatal breathing was simulated using a mechanical lung simulator. Seven ventilators were tested at different CPAP levels using two breath profiles. Pressure stability and iWOB were determined. Results from three ventilators revealed that they provided a slight pressure support. For these ventilators, iWOB could not be calculated. There were large differences in pressure stability and iWOB between the tested ventilators. For simulations using the 3.4-kg breath profile, the pressure swings around the mean pressure were more than five times greater, and iWOB more than four times higher, for the system with the highest measured values compared with the system with the lowest. Overall, the Fabian ventilator was the most pressure stable system. Evita XL and SERVO-i were found more pressure stable than Fabian in some simulations. The results for iWOB were in accordance with pressure stability for systems that allowed determination of this variable. Some of the tested ventilators unexpectedly provided a minor degree of pressure support. In terms of pressure stability, we have not found any advantages of ventilators as a group compared with Bubble CPAP, Neopuff, and variable flow generators that were tested in our previous study. The variation between individual systems is great within both categories. The clinical importance of these findings needs further investigation.

  14. EXTUBATE: A randomised controlled trial of nasal biphasic positive airway pressure vs. nasal continuous positive airway pressure following extubation in infants less than 30 weeks' gestation: study protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Victor Suresh

    2011-12-01

    Full Text Available Abstract Background Respiratory distress syndrome remains a significant problem among premature infants. Mechanical ventilation through an endotracheal tube remains the mainstay of respiratory support but may be associated with lung injury and the development of chronic lung disease of prematurity. Efforts are needed to reduce the duration of mechanical ventilation in favour of less invasive forms of respiratory support and to improve rates of successful extubation. Non-invasive respiratory support has been demonstrated to be less injurious to the premature lung. Standard practice is to use nasal continuous positive airway pressure (n-CPAP following extubation to support the baby's breathing. Many clinicians also use nasal biphasic positive airway pressure (n-BiPAP in efforts to improve rates of successful extubation. However, there is currently no evidence that this confers any advantage over conventional nasal continuous positive airway pressure. Methods We propose an unblinded multi-centre randomised trial comparing n-CPAP with n-BiPAP in babies born before 30 weeks' gestation and less than two weeks old. Babies with congenital abnormalities and severe intra-ventricular haemorrhage will be excluded. 540 babies admitted to neonatal centres in England will be randomised at the time of first extubation attempt. The primary aim of this study is to compare the rate of extubation failure within 48 hours following the first attempt at extubation. The secondary aims are to compare the effect of n-BiPAP and n-CPAP on the following outcomes: 1. Maintenance of successful extubation for 7 days post extubation 2. Oxygen requirement at 28 days of age and at 36 weeks' corrected gestational age 3. Total days on ventilator, n-CPAP/n-BiPAP 4. Number of ventilator days following first extubation attempt 5. pH and partial pressure of carbon dioxide in the first post extubation blood gas 6. Duration of hospital stay 7. Rate of abdominal distension requiring

  15. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    Science.gov (United States)

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  16. Simulated driving in obstructive sleep apnoea-hypopnoea : effects of oral appliances and continuous positive airway pressure

    NARCIS (Netherlands)

    Hoekema, Aarnoud; Stegenga, Boudewijn; Bakker, Marije; Brouwer, Wiebo H.; de Bont, Lambert G. M.; Wijkstra, Peter J.; van der Hoeven, Johannes H.

    Impaired simulated driving performance has been demonstrated in obstructive sleep apnoea-hypopnoea syndrome (OSAHS) patients. Although continuous positive airway pressure (CPAP) generally improves simulated driving performance, the effects of oral-appliance (OA) therapy are unknown. The aims of this

  17. : ventilators for noninvasive ventilation

    OpenAIRE

    Fauroux , Brigitte; Leroux , Karl; Desmarais , Gilbert; Isabey , Daniel; Clément , Annick; Lofaso , Frédéric; Louis , Bruno

    2008-01-01

    International audience; The aim of the present study was to evaluate the performance characteristics of all the ventilators proposed for home noninvasive positive-pressure ventilation in children in France. The ventilators (one volume-targeted, 12 pressure-targeted and four dual) were evaluated on a bench which simulated six different paediatric ventilatory patterns. For each ventilator, the quality of the inspiratory and expiratory trigger and the ability to reach and maintain the preset pre...

  18. [Special artificial respiration procedures and intracranial pressure. Animal experiment studies, development and use of a new pressure measuring technic, clinical aspects].

    Science.gov (United States)

    Schedl, R

    1985-01-01

    We investigated the influence of Forced Diffusion Ventilation (FDV), a special form of High Frequency Ventilation (HFV), on elevated intracranial pressure (ICP) in 5 dogs. Elevation of ICP was standardized by inflation of an epidural balloon. A typical finding with FDV is a reduced intrapleural pressure and therefore one could expect a better cerebrovenous drainage influencing ICP. Nevertheless, we found no changes in mean ICP under conditions of FDV compared with IPPV. Respirator-synchronous fluctuations of ICP, cisternal cerebrospinal fluid pressure and intrapleural pressure were drastically reduced with FDV. This phenomenon has been already reported by other groups as a typical effect of HFV with rates of 100/min. One can speculate, that this immediate impact of HFV on ICP-curves might be of some advantage in patients with critically reduced intracranial compliance requiring long-term artificial ventilation, because peaks and amplitudes of ICP are reduced. Our clinical experience with High Frequency Pulsation (HFP) includes 11 patients with severe brain trauma. In clinical routine this method of HFV is more facile to applicate than FDV, because there is no need of a special endotracheal tube and sufficient CO2-elimination is not strongly dependent on precise position of the tube. But HFP, as FDV, includes all advantages of respiratory systems, that are open against atmosphere (coughing and simultaneous breathing, without drastically increasing airway pressure, suction during respiration, etc.). However, we could find no special advantages or disadvantages in ICP-course during long-term application of HFP (up to 10 days). Because application of HFV is dependent on special technical equipment, we investigated in 6 patients the influence of respiratory frequency, tidal volume and inspiratory flow on ICP-fluctuations using conventional ventilators. ICP was recorded by a new, self constructed pneumatic epidural pressure sensor. Ventilator-related ICP

  19. Distribution of peak expiratory flow variability by age, gender and smoking habits in a random population sample aged 20-70 yrs

    NARCIS (Netherlands)

    Boezen, H M; Schouten, J. P.; Postma, D S; Rijcken, B

    1994-01-01

    Peak expiratory flow (PEF) variability can be considered as an index of bronchial lability. Population studies on PEF variability are few. The purpose of the current paper is to describe the distribution of PEF variability in a random population sample of adults with a wide age range (20-70 yrs),

  20. Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment

    DEFF Research Database (Denmark)

    Wan, M.P.; To, G.N.S.; Chao, C.Y.H.

    2009-01-01

    to estimate the risk of infection by contact. The environmental control system (ECS) in a cabin creates air circulation mainly in the lateral direction, making lateral dispersions of aerosols much faster than longitudinal dispersions. Aerosols with initial sizes under 28 m in diameter can stay airborne......The transport and deposition of polydispersed expiratory aerosols in an aircraft cabin were simulated using a Lagrangian-based model validated by experiments conducted in an aircraft cabin mockup. Infection risk by inhalation was estimated using the aerosol dispersion data and a model was developed...

  1. Ventilation distribution measured with EIT at varying levels of pressure support and Neurally Adjusted Ventilatory Assist in patients with ALI.

    Science.gov (United States)

    Blankman, Paul; Hasan, Djo; van Mourik, Martijn S; Gommers, Diederik

    2013-06-01

    The purpose of this study was to compare the effect of varying levels of assist during pressure support (PSV) and Neurally Adjusted Ventilatory Assist (NAVA) on the aeration of the dependent and non-dependent lung regions by means of Electrical Impedance Tomography (EIT). We studied ten mechanically ventilated patients with Acute Lung Injury (ALI). Positive-End Expiratory Pressure (PEEP) and PSV levels were both 10 cm H₂O during the initial PSV step. Thereafter, we changed the inspiratory pressure to 15 and 5 cm H₂O during PSV. The electrical activity of the diaphragm (EAdi) during pressure support ten was used to define the initial NAVA gain (100 %). Thereafter, we changed NAVA gain to 150 and 50 %, respectively. After each step the assist level was switched back to PSV 10 cm H₂O or NAVA 100 % to get a new baseline. The EIT registration was performed continuously. Tidal impedance variation significantly decreased during descending PSV levels within patients, whereas not during NAVA. The dorsal-to-ventral impedance distribution, expressed according to the center of gravity index, was lower during PSV compared to NAVA. Ventilation contribution of the dependent lung region was equally in balance with the non-dependent lung region during PSV 5 cm H₂O, NAVA 50 and 100 %. Neurally Adjusted Ventilatory Assist ventilation had a beneficial effect on the ventilation of the dependent lung region and showed less over-assistance compared to PSV in patients with ALI.

  2. The influence of body position on cerebrospinal fluid pressure gradient and movement in cats with normal and impaired craniospinal communication.

    Science.gov (United States)

    Klarica, Marijan; Radoš, Milan; Erceg, Gorislav; Petošić, Antonio; Jurjević, Ivana; Orešković, Darko

    2014-01-01

    Intracranial hypertension is a severe therapeutic problem, as there is insufficient knowledge about the physiology of cerebrospinal fluid (CSF) pressure. In this paper a new CSF pressure regulation hypothesis is proposed. According to this hypothesis, the CSF pressure depends on the laws of fluid mechanics and on the anatomical characteristics inside the cranial and spinal space, and not, as is today generally believed, on CSF secretion, circulation and absorption. The volume and pressure changes in the newly developed CSF model, which by its anatomical dimensions and basic biophysical features imitates the craniospinal system in cats, are compared to those obtained on cats with and without the blockade of craniospinal communication in different body positions. During verticalization, a long-lasting occurrence of negative CSF pressure inside the cranium in animals with normal cranio-spinal communication was observed. CSF pressure gradients change depending on the body position, but those gradients do not enable unidirectional CSF circulation from the hypothetical site of secretion to the site of absorption in any of them. Thus, our results indicate the existence of new physiological/pathophysiological correlations between intracranial fluids, which opens up the possibility of new therapeutic approaches to intracranial hypertension.

  3. The influence of body position on cerebrospinal fluid pressure gradient and movement in cats with normal and impaired craniospinal communication.

    Directory of Open Access Journals (Sweden)

    Marijan Klarica

    Full Text Available Intracranial hypertension is a severe therapeutic problem, as there is insufficient knowledge about the physiology of cerebrospinal fluid (CSF pressure. In this paper a new CSF pressure regulation hypothesis is proposed. According to this hypothesis, the CSF pressure depends on the laws of fluid mechanics and on the anatomical characteristics inside the cranial and spinal space, and not, as is today generally believed, on CSF secretion, circulation and absorption. The volume and pressure changes in the newly developed CSF model, which by its anatomical dimensions and basic biophysical features imitates the craniospinal system in cats, are compared to those obtained on cats with and without the blockade of craniospinal communication in different body positions. During verticalization, a long-lasting occurrence of negative CSF pressure inside the cranium in animals with normal cranio-spinal communication was observed. CSF pressure gradients change depending on the body position, but those gradients do not enable unidirectional CSF circulation from the hypothetical site of secretion to the site of absorption in any of them. Thus, our results indicate the existence of new physiological/pathophysiological correlations between intracranial fluids, which opens up the possibility of new therapeutic approaches to intracranial hypertension.

  4. Effect of a mixture of pyridostigmine and atropine on forced expiratory volume (FEV1), and serum cholinesterase activity in normal subjects

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, B F; Gefke, Kaj; Mosbech, H

    1985-01-01

    injection with a decrease to 27 +/- 5% (mean +/- SEM) of the original activity. Forced expiratory volume in the first 1s (FEV1) was measured at fixed time intervals for 90 min. No decrease in FEV1 was observed; on the contrary, there was a small increase. We conclude that atropine effectively antagonizes...

  5. Normal expiratory flow rate and lung volumes in patients with combined emphysema and interstitial lung disease: a case series and literature review.

    Science.gov (United States)

    Heathcote, Karen L; Cockcroft, Donald W; Fladeland, Derek A; Fenton, Mark E

    2011-01-01

    Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.

  6. Analysis of the effects of non-supine sleeping positions on the stress, strain, deformation and intraocular pressure of the human eye

    Science.gov (United States)

    Volpe, Peter A.

    This thesis presents analytical models, finite element models and experimental data to investigate the response of the human eye to loads that can be experienced when in a non-supine sleeping position. The hypothesis being investigated is that non-supine sleeping positions can lead to stress, strain and deformation of the eye as well as changes in intraocular pressure (IOP) that may exacerbate vision loss in individuals who have glaucoma. To investigate the quasi-static changes in stress and internal pressure, a Fluid-Structure Interaction simulation was performed on an axisymmetrical model of an eye. Common Aerospace Engineering methods for analyzing pressure vessels and hyperelastic structural walls are applied to developing a suitable model. The quasi-static pressure increase was used in an iterative code to analyze changes in IOP over time.

  7. European Society of Hypertension position paper on ambulatory blood pressure monitoring.

    Science.gov (United States)

    O'Brien, Eoin; Parati, Gianfranco; Stergiou, George; Asmar, Roland; Beilin, Laurie; Bilo, Grzegorz; Clement, Denis; de la Sierra, Alejandro; de Leeuw, Peter; Dolan, Eamon; Fagard, Robert; Graves, John; Head, Geoffrey A; Imai, Yutaka; Kario, Kazuomi; Lurbe, Empar; Mallion, Jean-Michel; Mancia, Giuseppe; Mengden, Thomas; Myers, Martin; Ogedegbe, Gbenga; Ohkubo, Takayoshi; Omboni, Stefano; Palatini, Paolo; Redon, Josep; Ruilope, Luis M; Shennan, Andrew; Staessen, Jan A; vanMontfrans, Gert; Verdecchia, Paolo; Waeber, Bernard; Wang, Jiguang; Zanchetti, Alberto; Zhang, Yuqing

    2013-09-01

    Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.

  8. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  9. Delivery room continuous positive airway pressure and early pneumothorax in term newborn infants.

    Science.gov (United States)

    Clevenger, L; Britton, J R

    2017-01-01

    To assess the association between delivery room (DR) continuous positive airway pressure (CPAP) and pneumothorax (PT) in term newborns. Two studies performed in community hospitals used data extracted from computerized records of term newborns. Infants receiving positive pressure ventilation in the DR were excluded. Tabulated data included receipt of DR CPAP, PT on the day of birth, and gestational age (GA). In a case-control study from 2001-2013, infants with PT were compared to controls without PT but with respiratory distress or hypoxia persisting from birth for receipt of DR CPAP. In a cohort study from 2014-2016, infants receiving and not receiving DR CPAP were compared for the incidence of PT. In the case-control study, data were obtained for 169 cases and 850 controls. Compared to controls, PT infants were more likely to have received DR CPAP (16.8% vs. 40.2%, respectively, P CPAP (Adjusted Odds Ratio [AOR] = 3.30, 95% confidence interval [CI] = 2.31, 4.72, P CPAP and 4.8% of 228 infants receiving DR CPAP (P CPAP significantly predicted PT (OR = 59.59, 95% CI = 23.34, 147.12, P CPAP in delivery rooms are associated with increased risk of PT. A cause-and-effect relationship between CPAP and PT cannot be claimed in this study. Further research is needed to better understand this relationship.

  10. Novel application of lower body positive-pressure in the rehabilitation of an individual with multiple lower extremity fractures.

    Science.gov (United States)

    Takacs, Judit; Leiter, Jeff R S; Peeler, Jason D

    2011-06-01

    Lower extremity fractures, if not treated appropriately, can increase the risk of morbidity. Partial weight-bearing after surgical repair is recommended; however, current methods of partial weight-bearing may cause excessive loads through the lower extremity. A new rehabilitation tool that uses lower body positive-pressure is described, that may allow partial weight-bearing while preventing excessive loads, thereby improving functional outcomes. A patient with multiple lower extremity fractures underwent a 6-month rehabilitation programme using bodyweight support technology 3 times per week, post-surgery. The patient experienced a reduction in pain and an improvement in ankle range of motion (p=0.002), walking speed (p>0.05) and physical function (p=0.004), as assessed by the Foot and Ankle Module of the American Academy of Orthopaedic Surgeons Lower Limb Outcomes Assessment Instrument. Training did not appear to affect fracture healing, as was evident on radiograph. The effect of lower body positive-pressure on effusion, which has not previously been reported in the literature, was also investigated. No significant difference in effusion of the foot and ankle when using lower body positive-pressure was found. Initial results suggest that this new technology may be a useful rehabilitation tool that allows partial weight-bearing during the treatment of lower extremity injuries.

  11. Use of dynamic CT in acute respiratory distress syndrome (ARDS) with comparison of positive and negative pressure ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Helm, Emma; Babyn, Paul [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Talakoub, Omid; Alirezaie, Javad [Ryerson University, Department of Electrical and Computer Engineering, Toronto, ON (Canada); Grasso, Francesco; Engelberts, Doreen; Kavanagh, Brian P. [Hospital for Sick Children and the University of Toronto, Departments of Anesthesia and Critical Care Medicine and the Program in Pulmonary and Experimental Medicine, Toronto (Canada)

    2009-01-15

    Negative pressure ventilation via an external device ('iron lung') has the potential to provide better oxygenation with reduced barotrauma in patients with ARDS. This study was designed to see if oxygenation differences between positive and negative ventilation could be explained by CT. Six anaesthetized rabbits had ARDS induced by repeated saline lavage. Rabbits were ventilated with positive pressure ventilation (PPV) and negative pressure ventilation (NPV) in turn. Dynamic CT images were acquired over the respiratory cycle. A computer-aided method was used to segment the lung and calculate the range of CT densities within each slice. Volumes of ventilated lung and atelectatic lung were measured over the respiratory cycle. NPV was associated with an increased percentage of ventilated lung and decreased percentage of atelectatic lung. The most significant differences in ventilation and atelectasis were seen at mid-inspiration and mid-expiration (ventilated lung NPV=61%, ventilated lung PPV=47%, p<0.001; atelectatic lung NPV=10%, atelectatic lung PPV 19%, p<0.001). Aeration differences were not significant at end-inspiration. Dynamic CT can show differences in lung aeration between positive and negative ventilation in ARDS. These differences would not be appreciated if only static breath-hold CT was used. (orig.)

  12. Effect of an automatic triggering and cycling system on comfort and patient-ventilator synchrony during pressure support ventilation.

    Science.gov (United States)

    Vasconcelos, Renata dos S; Melo, Luíz Henrique de P; Sales, Raquel P; Marinho, Liégina S; Deulefeu, Flávio C; Reis, Ricardo C; Alves-de-Almeida, Mirizana; Holanda, Marcelo A

    2013-01-01

    The digital Auto-Trak™ system is a technology capable of automatically adjusting the triggering and cycling mechanisms during pressure support ventilation (PSV). To compare Auto-Trak with conventional settings in terms of patient-ventilator synchrony and discomfort. Twelve healthy volunteers underwent PSV via the mouth by breathing through an endotracheal tube. In the conventional setting, a pressure support of 8 cm H2O with flow cycling (25% peak inspiratory flow) and a sensitivity of 1 cm H2O was adjusted. In Auto-Trak the triggering and cycling were automatically set. Discomfort, effort of breathing, and the asynchrony index (AI) were assessed. In a complementary bench study, the inspiratory and expiratory time delays were quantified for both settings in three mechanical models: 'normal', obstructive (COPD), and restrictive (ARDS), using the ASL 5000 simulator. In the volunteer study the AI and the discomfort scores did not differ statistically between the two settings. In the bench investigation the use of Auto-Trak was associated with a greater triggering delay in the COPD model and earlier expiratory cycling in the ARDS model but with no asynchronic events. Use of the Auto-Trak system during PSV showed similar results in comparison to the conventional adjustments with respect to patient-ventilator synchrony and discomfort in simulated conditions of invasive mechanical ventilation. Copyright © 2013 S. Karger AG, Basel.

  13. Flow-synchronized nasal intermittent positive pressure ventilation in the preterm infant: development of a project

    Directory of Open Access Journals (Sweden)

    Corrado Moretti

    2013-06-01

    Full Text Available This manuscript describes the experience of our team in developing a flow-triggered nasal respiratory support for the neonate and its related clinical applications. Although mechanical ventilation (MV via an endotracheal tube has undoubtedly led to improvement in neonatal survival in the last 40 years, the prolonged use of this technique may predispose the infant to the development of many possible complications, first of all, bronchopulmonary dysplasia (BPD. Avoiding mechanical ventilation is thought to be a critical goal, and different modes of non invasive respiratory support may reduce the intubation rate: nasal continuous positive airway pressure (NCPAP, nasal intermittent positive pressure ventilation (NIPPV and its more advantageous form, synchronized nasal intermittent positive pressure ventilation (SNIPPV. SNIPPV was initially performed by a capsule placed on the baby’s abdomen. To overcome the disadvantages of the abdominal capsule, our team decided to create a flow-sensor that could be interposed between the nasal prongs and the Y piece. Firstly we developed a hot-wire flow-sensor to trigger the ventilator and we showed that flow-SNIPPV can support the inspiratory effort in the post-extubation period more effectively than NCPAP. But, although accurate, the proper functioning of the hot-wire flow-sensor was easily compromised by secretions or moisture, and therefore we started to use as flow-sensor a simpler differential pressure transducer. In a following trial using the new device, we were able to demonstrate that flow-SNIPPV was more effective than conventional NCPAP in decreasing extubation failure in preterm infants who had been ventilated for respiratory distress syndrome (RDS. More recently we used flow-SNIPPV as the primary mode of ventilation, after surfactant replacement, reducing MV need and favorably affecting short-term morbidities of treated premature infants. We also successfully applied SNIPPV to treat apnea of

  14. Continuous positive airway pressure reduces blood pressure in patients with obstructive sleep apnea; a systematic review and meta-analysis with 1000 patients.

    Science.gov (United States)

    Schein, Andressa S O; Kerkhoff, Alessandra C; Coronel, Christian C; Plentz, Rodrigo D M; Sbruzzi, Graciele

    2014-09-01

    Obstructive sleep apnea (OSA) may lead to the development of hypertension and therapy with continuous positive airway pressure (CPAP) can promote reduction in blood pressure. The objective of this study is to review systematically the effects of CPAP on blood pressure in patients with OSA. The search was conducted in the following databases, from their beginning until February 2013: MEDLINE, Embase, Cochrane CENTRAL, Lilacs and PEDro. In addition, a manual search was performed on references of published studies. Randomized clinical trials (RCTs) that used CPAP compared with placebo CPAP or subtherapeutic CPAP for treatment of patients with OSA and that evaluated office SBP and DBP and 24-h ambulatory blood pressure were selected. Sixteen RCTs were included among 3409 publications, totaling 1166 patients. The use of CPAP resulted in reductions in office SBP [-3.20  mmHg; 95% confidence interval (CI) -4.67 to -1.72] and DBP (-2.87  mmHg; 95% CI -5.18 to -0.55); in night-time SBP (-4.92  mmHg; 95% CI -8.70 to -1.14); in mean 24-h blood pressure (-3.56  mmHg; 95% CI -6.79 to -0.33), mean night-time blood pressure (-2.56  mmHg; 95% CI -4.43 to -0.68) and 24-h DBP (-3.46  mmHg; 95% CI -6.75 to -0.17). However, no significant change was observed in daytime SBP (-0.74  mmHg; 95% CI -3.90 to 2.41) and daytime DBP (-1.86  mmHg; 95% CI -4.55 to 0.83). Treatment with CPAP promoted significantly but small reductions in blood pressure in individuals with OSA. Further studies should be performed to evaluate the effects of long-term CPAP and the impact on cardiovascular risk.

  15. Pulmonar recruitment in acute respiratory distress syndrome. What is the best strategy?

    Directory of Open Access Journals (Sweden)

    Cíntia Lourenço Santos

    Full Text Available Supporting patients with acute respiratory distress syndrome (ARDS, using a protective mechanical ventilation strategy characterized by low tidal volume and limitation of positive end-expiratory pressure (PEEP is a standard practice in the intensive care unit. However, these strategies can promote lung de-recruitment, leading to the cyclic closing and reopening of collapsed alveoli and small airways. Recruitment maneuvers (RM can be used to augment other methods, like positive end-expiratory pressure and positioning, to improve aerated lung volume. Clinical practice varies widely, and the optimal method and patient selection for recruitment maneuvers have not been determined, considerable uncertainty remaining regarding the appropriateness of RM. This review aims to discuss recent findings about the available types of RM, and compare the effectiveness, indications and adverse effects among them, as well as their impact on morbidity and mortality in ARDS patients. Recent developments include experimental and clinical evidence that a stepwise extended recruitment maneuver may cause an improvement in aerated lung volume and decrease the biological impact seen with the traditionally used sustained inflation, with less adverse effects. Prone positioning can reduce mortality in severe ARDS patients and may be an useful adjunct to recruitment maneuvers and advanced ventilatory strategies, such noisy ventilation and BIVENT, which have been useful in providing lung recruitment.

  16. Choking under the pressure of a positive stereotype: gender identification and self-consciousness moderate men's math test performance.

    Science.gov (United States)

    Tagler, Michael J

    2012-01-01

    Choking under pressure occurs when an individual underperforms due to situational pressure. The present study examined whether being the target of a positive social stereotype regarding math ability causes choking among men. Gender identification and self-consciousness were hypothesized to moderate the effect of math-gender stereotypes on men's math test performance. Men high in self-consciousness but low in gender identification significantly underperformed when exposed to gender-relevant test instructions. No significant effects were found under a gender-irrelevant condition. These findings are discussed in the contexts of research on stereotype threat, stereotype lift, and choking under pressure.

  17. Pressure Sores

    Science.gov (United States)

    Pressure sores are areas of damaged skin caused by staying in one position for too long. They commonly ... wheelchair, or are unable to change your position. Pressure sores can cause serious infections, some of which are ...

  18. Numerical and experimental study of expiratory flow in the case of major upper airway obstructions with fluid structure interaction

    Science.gov (United States)

    Chouly, F.; van Hirtum, A.; Lagrée, P.-Y.; Pelorson, X.; Payan, Y.

    2008-02-01

    This study deals with the numerical prediction and experimental description of the flow-induced deformation in a rapidly convergent divergent geometry which stands for a simplified tongue, in interaction with an expiratory airflow. An original in vitro experimental model is proposed, which allows measurement of the deformation of the artificial tongue, in condition of major initial airway obstruction. The experimental model accounts for asymmetries in geometry and tissue properties which are two major physiological upper airway characteristics. The numerical method for prediction of the fluid structure interaction is described. The theory of linear elasticity in small deformations has been chosen to compute the mechanical behaviour of the tongue. The main features of the flow are taken into account using a boundary layer theory. The overall numerical method entails finite element solving of the solid problem and finite differences solving of the fluid problem. First, the numerical method predicts the deformation of the tongue with an overall error of the order of 20%, which can be seen as a preliminary successful validation of the theory and simulations. Moreover, expiratory flow limitation is predicted in this configuration. As a result, both the physical and numerical models could be useful to understand this phenomenon reported in heavy snorers and apneic patients during sleep.

  19. Continuous positive airway pressure breathing increases cranial spread of sensory blockade after cervicothoracic epidural injection of lidocaine.

    NARCIS (Netherlands)

    Visser, W.A.; Eerd, M.J. van; Seventer, R. van; Gielen, M.J.M.; Giele, J.L.P.; Scheffer, G.J.

    2007-01-01

    BACKGROUND: Continuous positive airway pressure (CPAP) increases the caudad spread of sensory blockade after low-thoracic epidural injection of lidocaine. We hypothesized that CPAP would increase cephalad spread of blockade after cervicothoracic epidural injection. METHODS: Twenty patients with an

  20. Open-lung protective ventilation with pressure control ventilation, high-frequency oscillation, and intratracheal pulmonary ventilation results in similar gas exchange, hemodynamics, and lung mechanics.

    Science.gov (United States)

    Sedeek, Khaled A; Takeuchi, Muneyuki; Suchodolski, Klaudiusz; Vargas, Sara O; Shimaoka, Motomu; Schnitzer, Jay J; Kacmarek, Robert M

    2003-11-01

    Pressure control ventilation (PCV), high-frequency oscillation (HFO), and intratracheal pulmonary ventilation (ITPV) may all be used to provide lung protective ventilation in acute respiratory distress syndrome, but the specific approach that is optimal remains controversial. Saline lavage was used to produce acute respiratory distress syndrome in 21 sheep randomly assigned to receive PCV, HFO, or ITPV as follows: positive end-expiratory pressure (PCV and ITPV) and mean airway pressure (HFO) were set in a pressure-decreasing manner after lung recruitment that achieved a ratio of Pao2/Fio2 > 400 mmHg. Respiratory rates were 30 breaths/min, 120 breaths/min, and 8 Hz, respectively, for PCV, ITPV, and HFO. Eucapnia was targeted with peak carinal pressure of no more than 35 cm H2O. Animals were then ventilated for 4 h. There were no differences among groups in gas exchange, lung mechanics, or hemodynamics. Tidal volume (PCV, 8.9 +/- 2.1 ml/kg; ITPV, 2.7 +/- 0.8 ml/kg; HFO, approximately 2.0 ml/kg) and peak carinal pressure (PCV, 30.6 +/- 2.6 cm H2O; ITPV, 22.3 +/- 4.8 cm H2O; HFO, approximately 24.3 cm H2O) were higher in PCV. Pilot histologic data showed greater interstitial hemorrhage and alveolar septal expansion in PCV than in HFO or ITPV. These data indicate that HFO, ITPV, and PCV when applied with an open-lung protective ventilatory strategy results in the same gas exchange, lung mechanics, and hemodynamic response, but pilot data indicate that lung injury may be greater with PCV.

  1. Evaluation of a new pediatric positive airway pressure mask.

    Science.gov (United States)

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  2. Noninvasive positive pressure ventilation in acute asthmatic attack

    Directory of Open Access Journals (Sweden)

    A. Soroksky

    2010-03-01

    Full Text Available Asthma is characterised by reversible airway obstruction. In most patients, control of disease activity is easily achieved. However, in a small minority, asthma may be fatal. Between the two extremes lie patients with severe asthmatic attacks, refractory to standard treatment. These patients are at an increased risk of recurrent severe attacks, with respiratory failure, and mechanical ventilation. Invasive mechanical ventilation of the asthmatic patient is associated with a higher risk of complications and, therefore, is a measure of last resort. Noninvasive positive pressure ventilation (NPPV is another treatment modality that may be beneficial in patients with severe asthmatic attack who are at an increased risk of developing respiratory failure. These patients have the potential to benefit from early respiratory support in the form of NPPV. However, reports of NPPV in asthmatic patients are scarce, and its usage in asthmatic attacks is, therefore, still controversial. Only a few reports of NPPV in asthma have been published over the last decade. These studies mostly involve small numbers of patients and those who have problematic methodology. In this article we review the available evidence for NPPV in asthma and try to formulate our recommendations for NPPV application in asthma based on the available evidence and reports.

  3. Determination of respiratory system compliance during pressure support ventilation by small variations of pressure support.

    Science.gov (United States)

    Becher, Tobias; Schädler, Dirk; Rostalski, Philipp; Zick, Günther; Frerichs, Inéz; Weiler, Norbert

    2017-09-22

    In mechanically ventilated patients, measurement of respiratory system compliance (C rs ) is of high clinical interest. Spontaneous breathing activity during pressure support ventilation (PSV) can impede the correct assessment of C rs and also alter the true C rs by inducing lung recruitment. We describe a method for determination of C rs during PSV and assess its accuracy in a study on 20 mechanically ventilated patients. To assess C rs during pressure support ventilation (C rs,PSV ), we performed repeated changes in pressure support level by ± 2 cmH 2 O. C rs,PSV was calculated from the volume change induced by these changes in pressure support level, taking into account the inspiration time and the expiratory time constant. As reference methods, we used C rs , measured during volume controlled ventilation (C rs,VCV ). In a post-hoc analysis, we assessed C rs during the last 20% of the volume-controlled inflation (C rs,VCV20 ). Values were compared by linear regression and Bland-Altman methods comparison. Comparing C rs,PSV to the reference value C rs,VCV , we found a coefficient of determination (r 2 ) of 0.90, but a relatively high bias of - 7 ml/cm H 2 O (95% limits of agreement - 16.7 to + 2.7 ml/cmH 2 O). Comparison with C rs,VCV20 resulted in a negligible bias (- 1.3 ml/cmH 2 O, 95% limits of agreement - 13.9 to + 11.3) and r 2 of 0.81. We conclude that the novel method provides an estimate of end-inspiratory C rs during PSV. Despite its limited accuracy, it might be useful for non-invasive monitoring of C rs in patients undergoing pressure support ventilation.

  4. Positional change in blood pressure and 8-year risk of hypertension: the CARDIA Study.

    Science.gov (United States)

    Thomas, Randal J; Liu, Kiang; Jacobs, David R; Bild, Diane E; Kiefe, Catarina I; Hulley, Stephen B

    2003-08-01

    To assess the relationship between positional blood pressure change and 8-year incidence of hypertension in a biracial cohort of young adults. Participants from the Coronary Artery Risk Development in Young Adults (CARDIA) study with complete data from year 2 (1987-1988), year 5 (1990-1991), year 7 (1992-1993), and year 10 (1995-1996) examinations were included (N = 2781). Participants were classified into 3 groups based on their year 2 systolic blood pressure response to standing: drop, a decrease in systolic blood pressure of more than 5 mm Hg; same, a change of between -5 and +5 mm Hg; and rise, more than 5-mm Hg increase. The number of participants in each group was as follows: drop, 741; same, 1590; and rise, 450. The 8-year incidence of hypertension was 8.4% in the drop group, 6.8% in the same group, and 12.4% in the rise group (P women, 2.47 (95% CI, 1.19-5.11), in white men, 2.17 (95% CI, 1.00-4.73), and in white women, 4.74 (95% CI, 1.11-20.30). A greater than 5-mm Hg increase in blood pressure on standing identified a group of young adults at increased risk of developing hypertension within 8 years. These findings support a physiologic link between sympathetic nervous system reactivity and risk of hypertension in young adults.

  5. Positive pressure ventilation in the management of acute and chronic cardiac failure: a systematic review and meta-analysis.

    Science.gov (United States)

    Nadar, Sunil; Prasad, Neeraj; Taylor, Rod S; Lip, Gregory Y H

    2005-03-18

    Chronic heart failure (CHF) is a common condition and is associated with excess morbidity and mortality, in spite of the many advances in its treatment. Chronic stable heart failure is also associated with an increased incidence of sleep-related breathing disorders, such as central sleep apnoea (CSA) and Cheyne Stokes respiration (CSR). Continuous positive airways pressure (CPAP) has been shown to alleviate the symptoms of CHF, improve left ventricular function and oxygenation. To a certain extent, CPAP also abolishes sleep-related breathing disorders in patients with chronic heart failure. In patients with acute pulmonary oedema, the use of positive pressure ventilation improves cardiac haemodynamic indices, as well as symptoms and oxygenation, and is associated with a lower need for intubation. However, some studies have cast doubts about its safety and suggest a higher rate of myocardial infarction associated with its use. In our opinion, non-invasive positive pressure ventilation and CPAP offers an adjunctive mode of therapy in patients with acute pulmonary oedema and chronic heart failure, who may not be suitable for intubation and in those not responsive to conventional therapies. Non-invasive ventilation also helps to improve oxygenation in those patients with exhaustion and respiratory acidosis. Many trials are still ongoing and the results of these studies would throw more light on the present role of non-invasive ventilation in the management of CHF.

  6. The antigravity suit in neurosurgery. Cardiovascular responses in seated neurosurgical patients.

    Science.gov (United States)

    Brodrick, P M; Ingram, G S

    1988-09-01

    The haemodynamic responses associated with inflation of the antigravity suit (G suit, aviation type) to 8.0 kPa were studied in a series of 40 patients who underwent neurosurgical operations in the sitting position. The study showed statistically significant increases in systolic arterial pressure (p less than 0.005) and mean central venous pressure (p less than 0.001) with inflation of the suit. The systolic arterial and mean central venous pressures remained significantly elevated immediately before deflation of the suit at the end of the operation (p less than 0.001 and p less than 0.005 respectively). The addition of 0.8-1.0 kPa positive end expiratory pressure during suit inflation was also investigated. A further increase in central venous pressure occurred but this did not achieve statistical significance.

  7. [Management of patients receiving home respiratory care with tracheostomy and positive-pressure ventilation].

    Science.gov (United States)

    Aoki, Masashi

    2013-01-01

    On March 11, 2011, the Great East Japan Earthquake occurred and a massive tsunami hit the northeastern coast of Japan. In Miyagi prefecture in Tokoku district, 49 patients with amyotrophic lateral sclerosis were supported by home respiratory care with tracheostomy and positive-pressure ventilation at that time. Among them, two patients were died in the tsunami and 25 patients were forced to evacuate to hospitals. We should hurry to submit a guideline for medical transportation for patients with neuromuscular diseases requiring artificial ventilation. We also should research the disaster medicine in the field of neurology.

  8. Noninvasive positive pressure ventilation in unplanned extubation

    Energy Technology Data Exchange (ETDEWEB)

    Eryuksel, Emel; Sait, Karakurt; Celikel, Turgay [Dept. of Pulmonary and Critical Care, Marmara Univ. Hospital, (Turkey)

    2009-07-01

    Unplanned extubation is quite common in intensive care unit (ICU) patients receiving mechanical ventilatory support. The present study aimed to investigate the effectiveness of noninvasive positive pressure ventilation (NPPV) in patients with unplanned extubation. A total of 15 patients (12 male, age: 57 + - 24 years, APACHE II score: 19 + - 7) monitored at the medical ICU during the year 2004 who developed unplanned extubation were included in the study. NPPV was tried in all of them following unplanned extubation. Indications for admission to the ICU were as follows: nine patients with pneumonia, three with status epilepticus, one with gastrointestinal bleeding, one with cardiogenic pulmonary edema and one with diffuse alveolar bleeding. Eleven of the patients (74%) were at the weaning period at the time of unplanned extubation. Among these 11 patients, NPPV was successful in 10 (91%) and only one (9%) was reintubated due to the failure of NPPV. The remaining four patients (26%) had pneumonia and none of them were at the weaning period at the time of extubation, but their requirement for mechanical ventilation was gradually decreasing. Unfortunately, an NPPV attempt for 6-8 h failed and these patients were reintubated. Patients with unplanned extubation before the weaning criteria are met should be intubated immediately. On the other hand, when extubation develops during the weaning period, NPPV may be an alternative. The present study was conducted with a small number of patients, and larger studies on the effectiveness of NPPV in unplanned extubation are warranted for firm conclusions. (author)

  9. Noninvasive positive pressure ventilation in unplanned extubation

    International Nuclear Information System (INIS)

    Eryuksel, Emel; Karakurt Sait; Celikel, Turgay

    2009-01-01

    Unplanned extubation is quite common in intensive care unit (ICU) patients receiving mechanical ventilatory support. The present study aimed to investigate the effectiveness of noninvasive positive pressure ventilation (NPPV) in patients with unplanned extubation. A total of 15 patients (12 male, age: 57 + - 24 years, APACHE II score: 19 + - 7) monitored at the medical ICU during the year 2004 who developed unplanned extubation were included in the study. NPPV was tried in all of them following unplanned extubation. Indications for admission to the ICU were as follows: nine patients with pneumonia, three with status epilepticus, one with gastrointestinal bleeding, one with cardiogenic pulmonary edema and one with diffuse alveolar bleeding. Eleven of the patients (74%) were at the weaning period at the time of unplanned extubation. Among these 11 patients, NPPV was successful in 10 (91%) and only one (9%) was reintubated due to the failure of NPPV. The remaining four patients (26%) had pneumonia and none of them were at the weaning period at the time of extubation, but their requirement for mechanical ventilation was gradually decreasing. Unfortunately, an NPPV attempt for 6-8 h failed and these patients were reintubated. Patients with unplanned extubation before the weaning criteria are met should be intubated immediately. On the other hand, when extubation develops during the weaning period, NPPV may be an alternative. The present study was conducted with a small number of patients, and larger studies on the effectiveness of NPPV in unplanned extubation are warranted for firm conclusions. (author)

  10. A Randomized Trial of Low-Flow Oxygen versus Nasal Continuous Positive Airway Pressure in Preterm Infants

    DEFF Research Database (Denmark)

    Heiring, Christian; Steensberg, Jesper; Bjerager, Mia

    2015-01-01

    BACKGROUND: Nasal continuous positive airway pressure (nCPAP) stabilizes the residual volume and may decrease the risk of 'atelectotrauma', potentially promoting lung development in neonates. OBJECTIVES: To assess whether replacing nCPAP by low-flow O2 by nasal cannula affects lung function...... the a/A pO2 ratio or weight gain negatively. Thus, prolonged nCPAP seems not to have a positive effect on lung function at 28 days of life and replacement by low-flow O2 could reduce the cost of equipment and increase the ease of nursing....

  11. Normal Expiratory Flow Rate and Lung Volumes in Patients with Combined Emphysema and Interstitial Lung Disease: A Case Series and Literature Review

    Directory of Open Access Journals (Sweden)

    Karen L Heathcote

    2011-01-01

    Full Text Available Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.

  12. Symptoms of insomnia among patients with obstructive sleep apnea before and after two years of positive airway pressure treatment.

    Science.gov (United States)

    Björnsdóttir, Erla; Janson, Christer; Sigurdsson, Jón F; Gehrman, Philip; Perlis, Michael; Juliusson, Sigurdur; Arnardottir, Erna S; Kuna, Samuel T; Pack, Allan I; Gislason, Thorarinn; Benediktsdóttir, Bryndis

    2013-12-01

    To assess the changes of insomnia symptoms among patients with obstructive sleep apnea (OSA) from starting treatment with positive airway pressure (PAP) to a 2-y follow-up. Longitudinal cohort study. Landspitali--The National University Hospital of Iceland. There were 705 adults with OSA who were assessed prior to and 2 y after starting PAP treatment. PAP treatment for OSA. All patients underwent a medical examination along with a type 3 sleep study and answered questionnaires on health and sleep before and 2 y after starting PAP treatment. The change in prevalence of insomnia symptoms by subtype was assessed by questionnaire and compared between individuals who were using or not using PAP at follow-up. Symptoms of middle insomnia were most common at baseline and improved significantly among patients using PAP (from 59.4% to 30.7%, P insomnia tended to persist regardless of PAP treatment, and symptoms of late insomnia were more likely to improve among patients not using PAP. Patients with symptoms of initial and late insomnia at baseline were less likely to adhere to PAP (odds ratio [OR] 0.56, P = 0.007, and OR 0.53, P insomnia. Symptoms of initial and late insomnia, however, tended to persist regardless of positive airway pressure treatment and had a negative effect on adherence. Targeted treatment for insomnia may be beneficial for patients with obstructive sleep apnea comorbid with insomnia and has the potential to positively affect adherence to positive airway pressure.

  13. Avaliação da frequência cardíaca à medida de pressão expiratória máxima estática e à manobra de Valsalva em jovens saudáveis Heart rate assessment during maximal static expiratory pressure and Valsalva maneuver in healthy young men

    Directory of Open Access Journals (Sweden)

    Vinicius Minatel

    2012-10-01

    Full Text Available CONTEXTUALIZAÇÃO: A medida de pressão expiratória máxima (PEmáx possui algumas contraindicações, pois acredita-se que as respostas obtidas nessa medida são similares às respostas encontradas na manobra de Valsalva (MV. OBJETIVOS: O objetivo principal é avaliar a resposta da frequência cardíaca (FC durante a medida da PEmáx e da MV em jovens saudáveis, em diferentes posturas, para identificar se e em qual condição a PEmáx reproduz as respostas obtidas na MV e, adicionalmente, estimar o trabalho realizado nas manobras. MÉTODO: Doze jovens saudáveis foram avaliados, orientados e familiarizados com as manobras. A MV foi composta por um esforço expiratório (40 mmHg durante 15 segundos contra um manômetro. A PEmáx foi executada segundo a American Thoracic Society. Ambas as medidas foram realizadas nas posturas supino e sentado. Para a análise da variação da frequência cardíaca (∆FC, índice de Valsalva (IV, índice da PEmáx (IPEmáx e o trabalho estimado das manobras (Wtotal, Wisotime, Wtotal/∆FCtotal e Wisotime/∆FCisotime , utilizou-se ANOVA two-way com post-hoc de Holm-Sidak (pBACKGROUND: The measure of the maximal expiratory pressure (MEP has some contraindications, as it is believed that the responses obtained in this measure are similar to the Valsalva maneuver (VM. OBJECTIVE: The main purpose of this study was to evaluate the heart rate responses (HR during the MEP and the VM measures in healthy young men into different postures aiming to identify whether and in which situation the MEP reproduces the responses obtained in the VM. Additionally we aim to estimate the workload realized during the maneuvers. METHOD: Twelve healthy young men were evaluated, instructed and familiarized with the maneuvers. The VM was characterized by an expiratory effort (40 mmHg against a manometer for 15 seconds. The MEP measure has been performed according to the American Thoracic Society. Both measures were performed at sitting

  14. The NOFLO trial: low-flow nasal prongs therapy in weaning nasal continuous positive airway pressure in preterm infants.

    LENUS (Irish Health Repository)

    O'Donnell, Sinéad M

    2013-07-01

    To determine if low-flow nasal prongs therapy with room air, compared with no treatment, facilitates weaning from nasal continuous positive airway pressure (NCPAP) in very low birth weight (VLBW, birth weight <1500 g) infants.

  15. The Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP in Premature Neonates: A Cross-Over Clinical Trial Study

    Directory of Open Access Journals (Sweden)

    Mahnaz Jabraeili

    2018-01-01

    Full Text Available Background The most common cause of admission to neonatal intensive care units (NICU is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP. Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to nasal CPAP in premature neonates. Materials and Methods In this cross-over clinical trial, 50 premature neonates who were receiving nasal CPAP admitted to the NICU of Imam Reza Hospital, Kermanshah, Iran, were included. The neonates were randomly placed at three body positions (fetal, supine, and prone positions. Pain was measured by Astrid Lindgren Children’s Hospital Pain Scale Neonates (ALPS-Neo pain assessment scale. The collected data were analyzed using the SPSS software (Version 22.0. Results Significant difference existed regarding pain of nasal CPAP among body positions (p< 0.001. Mean (SD pain was 5.15 (0.822 in fetal position, 6.260 (0.747 in prone position and 7.326 (0.792 in supine position. Conclusion Body positioning in premature neonates under nasal CPAP in NICU can be effective as a non-pharmacologic method in alleviating pain due to nasal CPAP. Among the studied positions, the lowest pain score was seen in fetal position.

  16. Lung recruitment during mechanical positive pressure ventilation in the PICU: what can be learned from the literature?

    NARCIS (Netherlands)

    Halbertsma, F.J.; Hoeven, J.G. van der

    2005-01-01

    A literature review was conducted to assess the evidence for recruitment manoeuvres used in conventional mechanical positive pressure ventilation. A total of 61 studies on recruitment manoeuvres were identified: 13 experimental, 31 ICU, 6 PICU and 12 anaesthesia studies. Recruitment appears to be a

  17. A Dedicated Z-Stent for Acquired Saber-Sheath Tracheobronchomalacia

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Fujimoto, Hisashi Kobayashi; Sonomura, Tetsuo; Uetani, Kosaku; Nishida, Norifumi; Ohata, Masahiro; Sato, Morio; Yamada, Ryusaku

    1997-01-01

    The tracheobronchial lumen has a continuous horseshoe arch morphology. We formed Z-stents accordingly to support the weakened cartilagenous portions. With this type of stent we treated a patient with acquired saber-sheath type tracheobronchomalacia (TBM), Rayl's type II, Johnson's grade III, whose condition was aggravated even under positive end expiratory pressure (PEEP) therapy. The patient improved gradually. No immediate complication was observed. Bronchofiberscopic examination revealed that the tracheobronchial arcade was closely strut-braced and showed no expiratory collapse. Six months later, when the patient was intubated due to asthmatic attacks, tissue ingrowth through the stent was found and removed. There was no recurrence of TBM. The patient died 2 years later of pneumoconiosis

  18. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    Directory of Open Access Journals (Sweden)

    Jean Christian Borel

    Full Text Available RATIONALE: In obstructive sleep apnea patients (OSA, continuous positive airway pressure (CPAP adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. OBJECTIVE: To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. METHODS: Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. RESULTS: 2311 OSA (age = 57(12 years, apnea+hypopnea index = 41(21/h, 29% female were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5, depression, low effective pressure, and side effects. CONCLUSION: As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  19. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    Science.gov (United States)

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  20. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  1. Treatment of sleep central apnea with non-invasive mechanical ventilation with 2 levels of positive pressure (bilevel in a patient with myotonic dystrophy type 1

    Directory of Open Access Journals (Sweden)

    Ricardo Tera Akamine

    2014-06-01

    Bi-level positive airway pressure treatment at spontaneous/timed mode showed an improvement in snoring, apneas, and Epworth sleepiness scale decreased from 20 to 10. This case illustrates the beneficial effects of Bi-level positive airway pressure support in central sleep apnea syndrome of a patient with myotonic dystrophy type 1.

  2. Impediment in upper airway stabilizing forces assessed by phrenic nerve stimulation in sleep apnea patients

    Directory of Open Access Journals (Sweden)

    Vérin E

    2005-09-01

    Full Text Available Abstract Background The forces developed during inspiration play a key role in determining upper airway stability and the occurrence of nocturnal breathing disorders. Phrenic nerve stimulation applied during wakefulness is a unique tool to assess Upper airway dynamic properties and to measure the overall mechanical effects of the inspiratory process on UA stability. Objectives To compare the flow/pressure responses to inspiratory and expiratory twitches between sleep apnea subjects and normal subjects. Methods Inspiratory and expiratory twitches using magnetic nerve stimulation completed in eleven untreated sleep apnea subjects and ten normal subjects. Results In both groups, higher flow and pressure were reached during inspiratory twitches. The two groups showed no differences in expiratory twitch parameters. During inspiration, the pressure at which flow-limitation occurred was more negative in normals than in apneic subjects, but not reaching significance (p = 0.07. The relationship between pharyngeal pressure and flow adequately fitted with a polynomial regression model providing a measurement of upper airway critical pressure during twitch. This pressure significantly decreased in normals from expiratory to inspiratory twitches (-11.1 ± 1.6 and -15.7 ± 1.0 cm H2O respectively, 95% CI 1.6–7.6, p Conclusion Inspiratory-related upper airway dilating forces are impeded in sleep apnea patients.

  3. Effect of different levels of continuous positive airway pressure on the 99mTc-DTPA lung clearance

    Directory of Open Access Journals (Sweden)

    Dulciane Nunes Paiva

    2014-04-01

    Full Text Available Backgound and Objectives: Positive airway pressure continues (CPAP produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA, along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½ that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005. However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.

  4. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    OpenAIRE

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to...

  5. The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.

    Science.gov (United States)

    Zeri, Fabrizio; De Cusatis, Mario; Lupelli, Luigi; Swann, Peter Graham

    2016-01-01

    To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses. Copyright © 2016 The Authors. Published by Elsevier Espana.. All rights reserved.

  6. Male sex, height, weight, and body mass index can increase external pressure to calf region using knee-crutch-type leg holder system in lithotomy position.

    Science.gov (United States)

    Mizuno, Ju; Takahashi, Toru

    2016-01-01

    Well-leg compartment syndrome (WLCS) is one of the catastrophic complications related to prolonged surgical procedures performed in the lithotomy position, using a knee-crutch-type leg holder (KCLH) system, to support the popliteal fossae and calf regions. Obesity has been implicated as a risk factor in the lithotomy position-related WLCS during surgery. In the present study, we investigated the relationship between the external pressure (EP) applied to the calf region using a KCLH system in the lithotomy position and selected physical characteristics. Twenty-one young, healthy volunteers (21.4±0.5 years of age, eleven males and ten females) participated in this study. The KCLH system used was Knee Crutch(®). We assessed four types of EPs applied to the calf region: box pressure, peak box pressure, contact pressure, and peak contact pressure, using pressure-distribution measurement system (BIG-MAT(®)). Relationships between these four EPs to the calf regions of both lower legs and a series of physical characteristics (sex, height, weight, and body mass index [BMI]) were analyzed. All four EPs applied to the bilateral calf regions were higher in males than in females. For all subjects, significant positive correlations were observed between all four EPs and height, weight, and BMI. EP applied to the calf region is higher in males than in females when the subject is supported by a KCLH system in the lithotomy position. In addition, EP increases with the increase in height, weight, and BMI. Therefore, male sex, height, weight, and BMI may contribute to the risk of inducing WLCS.

  7. Continuous positive airway pressure for the treatment of obstructive sleep apnea.

    Science.gov (United States)

    Nurwidya, Fariz; Susanto, Agus Dwi; Juzar, Dafsah A; Kobayashi, Isao; Yunus, Faisal

    2016-01-01

    Obstructive sleep apnea (OSA) is a recurrent episode of partial or complete upper airway obstruction during sleep despite ongoing respiratory efforts and is implicated as the risk factor of cardiovascular disease. The OSA syndrome is typified by recurring partial or total occlusion of the pharynx, sleep fragmentation, episodes of gasping, and, eventually, daytime sleepiness. If it is left untreated, OSA syndrome can cause hypertension, coronary artery disease congestive heart disease, insulin resistance and death. In this review, we describe the pathogenesis and diagnosis of OSA. We also focused on the continuous positive airway pressure (CPAP) as the main therapy for OSA. CPAP has been shown to provide benefit for not only respiratory system, but also for cardiovascular system and metabolic system. Finally, we discussed briefly about the issue of adherence of using CPAP that could contribute to lower compliant in patient with OSA.

  8. Predicting uptake of continuous positive airway pressure (CPAP) therapy in obstructive sleep apnoea (OSA)

    DEFF Research Database (Denmark)

    Skinner, Timothy; McNeil, Lindsay; Olaithe, Michelle

    2013-01-01

    diagnosed with OSA. Epworth sleepiness scale (ESS), Fatigue Severity Scale, Depression Anxiety Stress Scale and Illness Perception Questionnaire-Revised (IPQ-R) were administered at time of sleep study. These, patient demographics and sleep study variables were used to determine factors predicting patient......Purpose: Obstructive sleep apnoea (OSA) is a common disorder, for which continuous positive airway pressure (CPAP) therapy is a standard treatment. Despite its well-established efficacy, many patients choose not to initiate CPAP treatment. The present study investigated the degree to which...

  9. Update: Non-Invasive Positive Pressure Ventilation in Chronic Respiratory Failure Due to COPD.

    Science.gov (United States)

    Altintas, Nejat

    2016-01-01

    Long-term non-invasive positive pressure ventilation (NPPV) has widely been accepted to treat chronic hypercapnic respiratory failure arising from different etiologies. Although the survival benefits provided by long-term NPPV in individuals with restrictive thoracic disorders or stable, slowly-progressing neuromuscular disorders are overwhelming, the benefits provided by long-term NPPV in patients with chronic obstructive pulmonary disease (COPD) remain under question, due to a lack of convincing evidence in the literature. In addition, long-term NPPV reportedly failed in the classic trials to improve important physiological parameters such as arterial blood gases, which might serve as an explanation as to why long-term NPPV has not been shown to substantially impact on survival. However, high intensity NPPV (HI-NPPV) using controlled NPPV with the highest possible inspiratory pressures tolerated by the patient has recently been described as a new and promising approach that is well-tolerated and is also capable of improving important physiological parameters such as arterial blood gases and lung function. This clearly contrasts with the conventional approach of low-intensity NPPV (LI-NPPV) that uses considerably lower inspiratory pressures with assisted forms of NPPV. Importantly, HI-NPPV was very recently shown to be superior to LI-NPPV in terms of improved overnight blood gases, and was also better tolerated than LI-NPPV. Furthermore, HI-NPPV, but not LI-NPPV, improved dyspnea, lung function and disease-specific aspects of health-related quality of life. A recent study showed that long-term treatment with NPPV with increased ventilatory pressures that reduced hypercapnia was associated with significant and sustained improvements in overall mortality. Thus, long-term NPPV seems to offer important benefits in this patient group, but the treatment success might be dependent on effective ventilatory strategies.

  10. [Domiciliary noninvasive positive pressure ventilation in chronic alveolar hypoventilation].

    Science.gov (United States)

    Casas, J P; Robles, A M; Pereyra, M A; Abbona, H L; López, A M

    2000-01-01

    Effectiveness of treatment with domiciliary nocturnal noninvasive positive pressure ventilation is analyzed in a group of patients with chronic alveolar hypoventilation of different etiologies. It was applied with two levels of pressure (BiPAP) via nasal mask. Criteria for evaluation were symptomatology and improvement in gas exchange. Data were analyzed by Student t tests. A total of 13 patients were included, mean age 55.7 range 20 to 76 years (5 male 8 female). Main diagnosis was tuberculosis in 6, four of them having had surgical procedure (thoracoplasty 2, frenicectomy 1 and neumonectomy 1), myopathy 3 (myasthenia gravis 1, muscular dystrophy 1 and diaphragmatic paralysis 1), obesity-hypoventilation syndrome 1, escoliosis 1, bronchiectasis 1 and cystic fibrosis 1. These last two patients were on waiting list for lung transplantation. At the moment of consultation, the symptoms were: dysnea 13/13 (100%), astenia 13/13 (100%), hypersomnolency 10/13 (77%), cephalea 9/13 (69%), leg edema 6/13 (46%), loss of memory 6/13 (46%). Regarding gas exchange, they showed hypoxemia and hypercapnia. Mean follow up was of 2.2 years (range 6 months to 4 years). Within the year, all 13 patients became less dyspneic. Astenia, hypersomnolency, cephalea, leg edema and memory loss disappeared. Improvement in gas exchange was: PaO2/FiO2 from 269 +/- 65.4 (basal) to 336.7 +/- 75.3 post-treatment (p = 0.0018). PaCO2 from 70.77 +/- 25.48 mmHg (basal) to 46.77 +/- 8.14 mmHg (p = 0.0013). Ventilatory support was discontinued en 5 patients: three because of pneumonia requiring intubation and conventional mechanical ventilation, two of them died and one is still with tracheostomy; One patient with bronchiectasis and one with cystic fibrosis were transplanted. The remaining eight patients are stable. In conclusion, chronic alveolar hypoventilation can be effectively treated with domiciliary nocturnal noninvasive ventilation. Long term improvement in symptomatology and arterial blood gases

  11. Comparison of devices for newborn ventilation in the delivery room.

    Science.gov (United States)

    Szyld, Edgardo; Aguilar, Adriana; Musante, Gabriel A; Vain, Nestor; Prudent, Luis; Fabres, Jorge; Carlo, Waldemar A

    2014-08-01

    To evaluate the effectiveness and safety of a T-piece resuscitator compared with a self-inflating bag for providing mask ventilation to newborns at birth. Newborns at ≥26 weeks gestational age receiving positive-pressure ventilation at birth were included in this multicenter cluster-randomized 2-period crossover trial. Positive-pressure ventilation was provided with either a self-inflating bag (self-inflating bag group) with or without a positive end-expiratory pressure valve or a T-piece with a positive end-expiratory pressure valve (T-piece group). Delivery room management followed American Academy of Pediatrics and International Liaison Committee on Resuscitation guidelines. The primary outcome was the proportion of newborns with heart rate (HR)≥100 bpm at 2 minutes after birth. A total of 1027 newborns were included. There was no statistically significant difference in the incidence of HR≥100 bpm at 2 minutes after birth between the T-piece and self-inflating bag groups: 94% (479 of 511) and 90% (466 of 516), respectively (OR, 0.65; 95% CI, 0.41-1.05; P=.08). A total of 86 newborns (17%) in the T-piece group and 134 newborns (26%) in the self-inflating bag group were intubated in the delivery room (OR, 0.58; 95% CI, 0.4-0.8; P=.002). The mean±SD maximum positive inspiratory pressure was 26±2 cm H2O in the T-piece group vs 28±5 cm H2O in the self-inflating bag group (P<.001). Air leaks, use of drugs/chest compressions, mortality, and days on mechanical ventilation did not differ significantly between groups. There was no difference between the T-piece resuscitator and a self-inflating bag in achieving an HR of ≥100 bpm at 2 minutes in newborns≥26 weeks gestational age resuscitated at birth. However, use of the T-piece decreased the intubation rate and the maximum pressures applied. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Inspiratory and expiratory HRCT findings in Behcet's disease and correlation with pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, Caner [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey)]. E-mail: cozer@mersin.edu.tr; Duce, Meltem Nass [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Ulubas, Bahar [Department of Respiratory Disease, Mersin University, Faculty of Medicine, Mersin (Turkey); Bicer, Ali [Department of Physical Medicine and Rehabilitation, Mersin University, Faculty of Medicine, Mersin (Turkey); Tuersen, Uemit [Department of Dermatology, Mersin University, Faculty of Medicine, Mersin (Turkey); Apaydin, F. Demir [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Yildiz, Altan [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Camdeviren, Handan [Department of Biostatistics, Mersin University, Faculty of Medicine, Mersin (Turkey)

    2005-10-01

    Purpose: The purpose of our study was to describe the pulmonary parenchymal changes of Behcet's disease using high-resolution computed tomography and to correlate them with pulmonary function tests. Materials and methods: Thirty-four patients with Behcet's disease (18 men, 16 women), 3 of whom were symptomatic, were included as the study group. Four of 34 patients were smokers. Twenty asymptomatic volunteers (12 men, 8 women), 4 of whom were smokers, constituted the control group. The pulmonary function tests and high-resolution computed tomography were performed for both groups. Results: Inspiratory high-resolution computed tomography findings were abnormal in nine patients (26.5%) of the study group. In eight patients, there were multiple abnormalities, whereas one patient had only one abnormality. Pleural thickening and irregularities, major fissure thickening, emphysematous changes, bronchiectasis, parenchymal bands, and irregular densities, and parenchymal nodules were the encountered abnormalities. Inspiratory high-resolution computed tomography scans were normal in the control group. On expiratory scans, there was statistically significant difference between study group and control group when air trapping, especially grades 3 and 4, was compared (P < 0.01). Pulmonary function tests of both the study and the control groups were in normal ranges, and there was no statistically significant difference between the two groups according to pulmonary function tests (P > 0.05). Discussion and conclusion: High-resolution computed tomography is sensitive in the demonstration of pulmonary changes in patients with Behcet's disease. End-expiratory high-resolution computed tomography examination is very useful and necessary to show the presence of air trapping, thus the presence of small airway disease, even if the patient is asymptomatic or has normal pulmonary function tests.

  13. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... Sleep Apnea? Lifestyle change including weight loss and exercise can help to improve sleep apnea and its related health problems. Sleep positioning and oral appliances have also been found to be effective. In cases when non-invasive treatments fail, a ...

  14. Continuous positive airway pressure treatment increases bronchial reactivity in obstructive sleep apnea patients.

    Science.gov (United States)

    Korczynski, Piotr; Gorska, Katarzyna; Przybylowski, Tadeusz; Bielicki, Piotr; Zielinski, Jan; Chazan, Ryszarda

    2009-01-01

    The effects of continuous positive airway pressure (CPAP) treatment on the function of the lower airways are poorly understood. One of the methods used to determine the influence of positive pressure breathing on lower airways is the bronchial hyperreactivity test. Some authors report that CPAP increases bronchial hyperreactivity, while others report decreases. To assess the influence of CPAP treatment on bronchial reactivity and the effects of bronchial hyperreactivity on compliance to CPAP treatment. The study group consisted of 101 obstructive sleep apnea syndrome patients (88 men and 13 women) with a mean age of 51 ± 11 years, mean apnea-hypopnea index of 53 ± 20 and mean body mass index of 32.6 ± 5.4. Patients were randomly assigned to a treatment group that received 3 weeks of CPAP therapy (group 1) or to a nontreatment control group (group 2). Pulmonary function tests and the methacholine bronchial provocation test were performed at baseline and 3 weeks later. There were no statistically significant differences between treated and control groups in anthropometry and polysomnography variables. At baseline, bronchial hyperreactivity was found in 6 patients from group 1 and 5 patients from group 2. A significant increase in bronchial reactivity was observed after CPAP treatment. Log PC20M decreased from 1.38 ± 0.30 at baseline to 1.26 ± 0.50 (p bronchial hyperreactivity during CPAP treatment were characterized by significantly lower FEV1, FVC and MEF50 values. CPAP produces statistically significant bronchial hyperreactivity. However, there were no clinical symptoms and it is not necessary to withdraw previous therapies. Copyright © 2009 S. Karger AG, Basel.

  15. The effect of positive and negative message framing on short term continuous positive airway pressure compliance in patients with obstructive sleep apnea.

    Science.gov (United States)

    Pengo, Martino F; Czaban, Marcin; Berry, Marc P; Nirmalan, Prajeshan; Brown, Richard; Birdseye, Adam; Woroszyl, Asia; Chapman, Julia; Kent, Brian D; Hart, Nicholas; Rossi, Gian Paolo; Steier, Joerg

    2018-01-01

    Continuous positive airway pressure (CPAP), the best available treatment for obstructive sleep apnea (OSA), requires long-term compliance to be effective. Behavioral interventions may be used to improve adherence to CPAP. We aimed to investigate whether positive or negative message framing impacts on CPAP compliance in patients with OSA, when compared to standard care. Consenting patients with confirmed OSA were randomly allocated to receive along with their CPAP either positively or negatively framed messages (Pos; Neg), or standard care (Con). Standardized motivational messages were read out to patients during an initial teaching session and through weekly telephone calls. Patients' compliance data were reviewed 2 and 6 weeks following CPAP initiation. We randomized 112 patients to groups that were matched for age, BMI, and OSA severity. The positively framed group (Pos) showed greater CPAP usage after 2 weeks (total use 53.7±31.4 hours) as compared to the negatively framed and the control group (35.6±27.4 and 40.8±33.5 hours, Pframed groups (Pos n=5; Neg n=8; Con n=11; Pframed messages can improve CPAP adherence in patients with OSA in the short-term; however, strategies for implementing its long-term use need to be developed.

  16. Positive outcome of average volume-assured pressure support mode of a Respironics V60 Ventilator in acute exacerbation of chronic obstructive pulmonary disease: a case report

    Directory of Open Access Journals (Sweden)

    Okuda Miyuki

    2012-09-01

    Full Text Available Abstract Introduction We were able to treat a patient with acute exacerbation of chronic obstructive pulmonary disease who also suffered from sleep-disordered breathing by using the average volume-assured pressure support mode of a Respironics V60 Ventilator (Philips Respironics: United States. This allows a target tidal volume to be set based on automatic changes in inspiratory positive airway pressure. This removed the need to change the noninvasive positive pressure ventilation settings during the day and during sleep. The Respironics V60 Ventilator, in the average volume-assured pressure support mode, was attached to our patient and improved and stabilized his sleep-related hypoventilation by automatically adjusting force to within an acceptable range. Case presentation Our patient was a 74-year-old Japanese man who was hospitalized for treatment due to worsening of dyspnea and hypoxemia. He was diagnosed with acute exacerbation of chronic obstructive pulmonary disease and full-time biphasic positive airway pressure support ventilation was initiated. Our patient was temporarily provided with portable noninvasive positive pressure ventilation at night-time following an improvement in his condition, but his chronic obstructive pulmonary disease again worsened due to the recurrence of a respiratory infection. During the initial exacerbation, his tidal volume was significantly lower during sleep (378.9 ± 72.9mL than while awake (446.5 ± 63.3mL. A ventilator that allows ventilation to be maintained by automatically adjusting the inspiratory force to within an acceptable range was attached in average volume-assured pressure support mode, improving his sleep-related hypoventilation, which is often associated with the use of the Respironics V60 Ventilator. Polysomnography performed while our patient was on noninvasive positive pressure ventilation revealed obstructive sleep apnea syndrome (apnea-hypopnea index = 14, suggesting that his chronic

  17. [Modification of expiratory peak flow (EPF) in 14 asthmatic subjects from Benin by short duration exercise training].

    Science.gov (United States)

    Lawani, M M; Hounkpatin, S; Akplogan, B

    2006-01-01

    Asthma is a world wide public health problem. It is the most commom chronic disease of school age children. Its severity is in constant increase. The frequency of the hospitalizations for asthma increased in practically all countries. Physical exercises and sport are used more and more as therapeutic means, in northern deveopped countries of where it was very early understood that it is necessary to integrate the asthmatic subjects into a program of specific physical training. This study undertaken in south saharian african country considers also assiduity in a physical training program as the factor of increase in the expiratory peak flow, of reinforcement of some principal muscles necessary to the improvement, and of the respiratory function of the asthmatic subject. Physical exercise is used as a non pharmacological therapy of asthma. This transversal study was carried out on fourteen asthmatic subjects of colleges in Porto-Novo's town, aged 15 years old to 25 years, of the two sexes. The results showed that: the Expiratory Peak Flow of Point (EPF) of the subjects at the beginning of the program is lower than the minimal average value of the group whatever the sex; the subjects average EPF increased from approximately 35% compared to the average at the beginning of the program; the subjects from family with asthmatic line, are much more inclined with respiratory embarrassments post-exercises than those who did not come from it; the respiratory embarrassments post-exercises noticed in the first weeks, grew blurred before the end of the program. This study suggests physical exercise adapted to the asthmatic subjects for the improvement of their health.

  18. Oral continuous positive airway pressure (CPAP) following nasal injury in a preterm infant.

    Science.gov (United States)

    Carlisle, H R; Kamlin, C O F; Owen, L S; Davis, P G; Morley, C J

    2010-03-01

    Non-invasive respiratory support is increasingly popular but is associated with complications including nasal trauma. The present report describes a novel method of oral continuous positive airway pressure (CPAP) delivery in an extremely premature infant with severe nasal septum erosion. The distal end of a cut down endotracheal tube was passed through a small hole made in the teat of a dummy (infant pacifier) and sutured in place. The dummy was secured in the infant's mouth and CPAP was delivered to the pharynx. The device was well tolerated and the infant was successfully managed using this technique for 48 days, avoiding endotracheal intubation and ventilation.

  19. Randomised trial of elective continuous positive airway pressure (CPAP) compared with rescue CPAP after extubation

    OpenAIRE

    Robertson, N; Hamilton, P

    1998-01-01

    AIM—To determine if a weaning regimen on flow driver continuous positive airway pressure (CPAP) would decrease the number of ventilator days but increase the number of CPAP days when compared with a rescue regimen.
METHODS—Fifty eight babies of 24-32 weeks gestation with respiratory distress syndrome (RDS) were studied prospectively. After extubation they were randomly allocated to receive CPAP for 72 hours (n=29) according to a weaning regimen, or were placed in headbox ...

  20. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    International Nuclear Information System (INIS)

    Matsuura, Yukiko; Kawata, Naoko; Yanagawa, Noriyuki; Sugiura, Toshihiko; Sakurai, Yoriko; Sato, Misuzu; Iesato, Ken; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Suzuki, Yoichi; Tatsumi, Koichiro

    2013-01-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm 2 as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers

  1. Changes in cardiac index and blood pressure on positioning children prone for scoliosis surgery.

    Science.gov (United States)

    Brown, Z E; Görges, M; Cooke, E; Malherbe, S; Dumont, G A; Ansermino, J M

    2013-07-01

    In this prospective observational study we investigated the changes in cardiac index and mean arterial pressure in children when positioned prone for scoliosis correction surgery. Thirty children (ASA 1-2, aged 13-18 years) undergoing primary, idiopathic scoliosis repair were recruited. The cardiac index and mean arterial blood pressure (median (IQR [range])) were 2.7 (2.3-3.1 [1.4-3.7]) l.min(-1).m(-2) and 73 (66-80 [54-91]) mmHg, respectively, at baseline; 2.9 (2.5-3.2 [1.7-4.4]) l.min(-1).m(-2) and 73 (63-81 [51-96]) mmHg following a 5-ml.kg(-1) fluid bolus; and 2.5 (2.2-2.7 [1.4-4.8]) l.min(-1).m(-2) and 69 (62-73 [46-85]) mmHg immediately after turning prone. Turning prone resulted in a median reduction in cardiac index of 0.5 l.min(-1).m(-2) (95% CI 0.3-0.7 l.min(-1).m(-2), p=0.001), or 18.5%, with a large degree of inter-subject variability (+10.3% to -40.9%). The changes in mean arterial blood pressure were not significant. Strategies to predict, prevent and treat decreases in cardiac index need to be developed. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  2. Transport of expiratory droplets in an aircraft cabin.

    Science.gov (United States)

    Gupta, Jitendra K; Lin, Chao-Hsin; Chen, Qingyan

    2011-02-01

    The droplets exhaled by an index patient with infectious disease such as influenza or tuberculosis may be the carriers of contagious agents. Indoor environments such as the airliner cabins may be susceptible to infection from such airborne contagious agents. The present investigation computed the transport of the droplets exhaled by the index patient seated in the middle of a seven-row, twin-aisle, fully occupied cabin using the CFD simulations. The droplets exhaled were from a single cough, a single breath, and a 15-s talk of the index patient. The expiratory droplets were tracked by using Lagrangian method, and their evaporation was modeled. It was found that the bulk airflow pattern in the cabin played the most important role on the droplet transport. The droplets were contained in the row before, at, and after the index patient within 30 s and dispersed uniformly to all the seven rows in 4 minutes. The total airborne droplet fraction reduced to 48, 32, 20, and 12% after they entered the cabin for 1, 2, 3, and 4 min, respectively, because of the ventilation from the environmental control system. It is critical to predict the risk of airborne infection to take appropriate measures to control and mitigate the risk. Most of the studies in past either assume a homogenous distribution of contaminants or use steady-state conditions. The present study instead provides information on the transient movement of the droplets exhaled by an index passenger in an aircraft cabin. These droplets may contain active contagious agents and can be potent enough to cause infection. The findings can be used by medical professionals to estimate the spatial and temporal distribution of risk of infection to various passengers in the cabin. © 2010 John Wiley & Sons A/S.

  3. Does personality play a role in continuous positive airway pressure compliance?

    Directory of Open Access Journals (Sweden)

    Emily L. Maschauer

    2017-03-01

    Continuous positive airway pressure (CPAP adherence is low among individuals with obstructive sleep apnoea. Type D personality and high scores on the depression and hypochondriasis scales on the Minnesota Multiphasic Personality Inventory (MMPI have been identified as factors contributing to non-compliance with CPAP. Further research into personality type may assist in understanding why some people adhere to CPAP, while others fail. Obstructive sleep apnoea (OSA is a condition characterised by repetitive, intermittent partial or complete collapse/obstruction of the upper airway during sleep. Continuous positive airway pressure (CPAP is highly efficacious in treating OSA but its effectiveness is limited due to suboptimal acceptance and adherence rates, with as many as 50% of OSA patients discontinuing CPAP treatment within the first year. Until recently, research has focused on examining mechanistic and demographic factors that could explain nonadherence (e.g. age, sex, race and education level with limited applicability in a prospective or clinical manner. More recent research has focused on personality factors or types of patients with OSA who comply and do not comply with CPAP adherence in an attempt to enhance the accuracy of predicting treatment compliance. Type D personality has been found to be prevalent in one third of patients with OSA. The presence of Type D personality increases noncompliance and poor treatment outcomes due to negative affectivity, social inhibition, unhealthy lifestyle, and a reluctance to consult and/or follow medical advice. Conversely, individuals who are more likely to adhere to CPAP treatment tend to have a high internal locus of control and high self-efficacy, self-refer for treatment, and have active coping skills. By assessing personality and coping skills, the clinician may gain insight into the likelihood of a patient’s adherence to treatment. If the patient displays potential risk factors for CPAP noncompliance, the

  4. Treatment of presumed acute cardiogenic pulmonary oedema in an ambulance system by nurses using Boussignac continuous positive airway pressure

    NARCIS (Netherlands)

    Dieperink, Willem; Weelink, E. E. M.; van der Horst, I. C. C.; de Vos, R.; Jaarsma, T.; Aarts, L. P. H. J.; Zijlstra, F.; Nijsten, M. W. N.

    Background: Early initiation of continuous positive airway pressure (CPAP) applied by face mask benefits patients with acute cardiogenic pulmonary oedema (ACPE). The simple disposable Boussignac CPAP (BCPAP) has been used in ambulances by physicians. In the Netherlands, ambulances are manned by

  5. Effect of bedding control on amount of house dust mite allergens, asthma symptoms, and peak expiratory flow rate.

    Science.gov (United States)

    Lee, Inn-Sook

    2003-04-30

    This quasi-experimental study was designed to investigate the effect of bedding control on the amount of house dust mite (HDM) allergens, asthma symptoms, and peak expiratory flow rate (PEFR) in asthmatics sensitive to HDMs. The subjects in the study were drawn from patients receiving treatment at the allergy clinics of three university-affiliated hospitals in Seoul. Forty-two patients without prior practice of the bedding control used in this study were selected. They commonly showed bronchial asthma caused by HDMs, and exhibited strong positive points (more than 3 points) in skin prick test (D. farinae, D. pteronyssinus), and positive response in both fluoro-allergosorbent test (FAST), and PC20 methacholine test. Of the subjects, alternatively, 22 were assigned to the experimental group and 20 to control group. Bedding control consisted of the use of outer cotton covers, boiling them for 10 minutes fortnightly, and disinfecting bedding by sunlight fortnightly. The experimental group was under bedding control for 4 weeks. The data were collected from October 2000 to January 2001. The results were as follows: 1. After bedding control, the total amount of HDM allergens decreased significantly in the experimental group. However there was no significant difference in the decrease of the amount of HDM allergens between the two groups. 2. Of the asthma symptoms, there was significant difference only in the decrease of the frequency of dyspnea, and in the increase of sleeping disturbance between the two groups after bedding control. 3. After bedding control, PEFR increased in the experimental group whereas it decreased in the control group. However, neither change was significant. The above findings indicate that bedding control improved several asthma symptoms in asthmatics sensitive to HDMs. Accordingly, we suggest that bedding control is adopted as a useful nursing intervention in the field.

  6. Verifying the Relative Efficacy between Continuous Positive Airway Pressure Therapy and Its Alternatives for Obstructive Sleep Apnea: A Network Meta-analysis

    Directory of Open Access Journals (Sweden)

    Tingwei Liu

    2017-06-01

    Full Text Available Obstructive sleep apnea (OSA is a common breathing disorder, and continuous positive airway pressure (CPAP therapy together with its alternatives has been developed to treat this disease. This network meta-analysis (NMA was aimed to compare the efficacy of treatments for OSA. Cochrane Library, MEDLINE, and Embase were searched for eligible studies. A conventional and NMA was carried out to compare all therapies. Sleeping characteristics, including Apnea–Hypopnea Index (AHI, Epworth Sleepiness Scale (ESS, arterial oxygen saturation, and arousal index (AI, and changes of blood pressure were selected as outcomes. A total of 84 studies were finally included after rigorous screenings. For the primary outcomes of AHI and ESS, the value of auto-adjusting positive airway pressure (APAP, CPAP, and oral appliance (OA all showed statistically reduction compared with inactive control (IC. Similar observation was obtained in AI, with treatments of the three active interventions. A lower effect of IC in SaO2 was exhibited when compared with APAP, CPAP, and OA. Similar statistically significant results were presented in 24 h systolic blood pressure and 24 h DBP when comparing with CPAP. Our NMA identified CPAP as the most efficacious treatment for OSA patients after the evaluation of sleeping characteristics and blood pressures. In addition, more clinical trials are needed for further investigation due to the existence of inconsistency observed in this study.

  7. Intra-operative protective mechanical ventilation in lung transplantation: a randomised, controlled trial.

    Science.gov (United States)

    Verbeek, G L; Myles, P S; Westall, G P; Lin, E; Hastings, S L; Marasco, S F; Jaffar, J; Meehan, A C

    2017-08-01

    Primary graft dysfunction occurs in up to 25% of patients after lung transplantation. Contributing factors include ventilator-induced lung injury, cardiopulmonary bypass, ischaemia-reperfusion injury and excessive fluid administration. We evaluated the feasibility, safety and efficacy of an open-lung protective ventilation strategy aimed at reducing ventilator-induced lung injury. We enrolled adult patients scheduled to undergo bilateral sequential lung transplantation, and randomly assigned them to either a control group (volume-controlled ventilation with 5 cmH 2 O, positive end-expiratory pressure, low tidal volumes (two-lung ventilation 6 ml.kg -1 , one-lung ventilation 4 ml.kg -1 )) or an alveolar recruitment group (regular step-wise positive end-expiratory pressure-based alveolar recruitment manoeuvres, pressure-controlled ventilation set at 16 cmH 2 O with 10 cmH 2 O positive end-expiratory pressure). Ventilation strategies were commenced from reperfusion of the first lung allograft and continued for the duration of surgery. Regular PaO 2 /F I O 2 ratios were calculated and venous blood samples collected for inflammatory marker evaluation during the procedure and for the first 24 h of intensive care stay. The primary end-point was the PaO 2 /F I O 2 ratio at 24 h after first lung reperfusion. Thirty adult patients were studied. The primary outcome was not different between groups (mean (SD) PaO 2 /F I O 2 ratio control group 340 (111) vs. alveolar recruitment group 404 (153); adjusted p = 0.26). Patients in the control group had poorer mean (SD) PaO 2 /F I O 2 ratios at the end of the surgical procedure and a longer median (IQR [range]) time to tracheal extubation compared with the alveolar recruitment group (308 (144) vs. 402 (154) (p = 0.03) and 18 (10-27 [5-468]) h vs. 15 (11-36 [5-115]) h (p = 0.01), respectively). An open-lung protective ventilation strategy during surgery for lung transplantation is feasible, safe and achieves favourable

  8. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents alveolar coagulation in patients without lung injury

    NARCIS (Netherlands)

    Choi, Goda; Wolthuis, Esther K.; Bresser, Paul; Levi, Marcel; van der Poll, Tom; Dzoljic, Misa; Vroom, Margreeth B.; Schultz, Marcus J.

    2006-01-01

    BACKGROUND: Alveolar fibrin deposition is a hallmark of acute lung injury, resulting from activation of coagulation and inhibition of fibrinolysis. Previous studies have shown that mechanical ventilation with high tidal volumes may aggravate lung injury in patients with sepsis and acute lung injury.

  9. Effects of inspiratory muscle training on pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation: a randomized controlled trial.

    Science.gov (United States)

    Zeren, Melih; Demir, Rengin; Yigit, Zerrin; Gurses, Hulya N

    2016-12-01

    To investigate the effects of inspiratory muscle training on pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation. Prospective randomized controlled single-blind study. Cardiology department of a university hospital. A total of 38 patients with permanent atrial fibrillation were randomly allocated to either a treatment group (n = 19; age 66.2 years (8.8)) or a control group (n = 19; age 67.1 years (6.4)). The training group received inspiratory muscle training at 30% of maximal inspiratory pressure for 15 minutes twice a day, 7 days a week, for 12 weeks alongside the standard medical treatment. The control group received standard medical treatment only. Spirometry, maximal inspiratory and expiratory pressures and 6-minute walking distance was measured at the beginning and end of the study. There was a significant increase in maximal inspiratory pressure (27.94 cmH 2 O (8.90)), maximal expiratory pressure (24.53 cmH 2 O (10.34)), forced vital capacity (10.29% (8.18) predicted), forced expiratory volume in one second (13.88% (13.42) predicted), forced expiratory flow 25%-75% (14.82% (12.44) predicted), peak expiratory flow (19.82% (15.62) predicted) and 6-minute walking distance (55.53 m (14.13)) in the training group (p  0.05). Inspiratory muscle training can improve pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation. © The Author(s) 2016.

  10. The Concave Shape of the Forced Expiratory Flow-Volume Curve in 3 Seconds Is a Practical Surrogate of FEV1/FVC for the Diagnosis of Airway Limitation in Inadequate Spirometry.

    Science.gov (United States)

    Li, Hao; Liu, Chunhong; Zhang, Yi; Xiao, Wei

    2017-03-01

    Spirometry is important for the differential diagnosis of dyspnea. However, some patients cannot exhale for ≥6 s to achieve the American Thoracic Society/European Respiratory Society criteria. The aim of this study was to demonstrate the reliability of a new parameter that quantifies the degree of concavity in the first 3 s to define airway limitation as a surrogate for the FEV 1 /FVC. Four hundred spirometry test results were selected through complete random sampling. The new parameter, termed the AUC 3 /AT 3 , was calculated as the area under the descending limb of the expiratory flow-volume curve before the end of the first 3 s (AUC 3 ) divided by the area of the triangle before the end of the first 3 s (AT 3 ). The AUC 3 /AT 3 was compared with the FEV 1 /FVC using Pearson's correlation analysis. The level of agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of airway obstruction was analyzed using the kappa statistic. We also compared the diagnostic accuracy of the new index with that of the FEV 1 /forced expiratory volume in the first 3 s (FEV 3 ). There was a strong correlation (r = 0.88, P < .001) between the AUC 3 /AT 3 and the FEV 1 /FVC. There was also strong agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of obstruction with kappa indices of 0.72 (Global Initiative for Chronic Obstructive Lung Disease [GOLD] criterion) and 0.67 (lower limit of normal criterion), and these values were greater than those obtained for the FEV 1 /FEV 3 . The AUC 3 /AT 3 also exhibited acceptable sensitivity, specificity, positive predictive value, and negative predictive value. The diagnostic accuracies of the AUC 3 /AT 3 were 86.3% (GOLD criterion) and 83.8% (lower limit of normal criterion), which were greater than the 76.0 and 74.0% obtained for the FEV 1 /FEV 3 , respectively. The AUC 3 /AT 3 can be utilized as a surrogate parameter for the FEV 1 /FVC when patients cannot complete a 6-s expiratory effort. Additionally, the

  11. How bacterial cell division might cheat turgor pressure - a unified mechanism of septal division in Gram-positive and Gram-negative bacteria.

    Science.gov (United States)

    Erickson, Harold P

    2017-08-01

    An important question for bacterial cell division is how the invaginating septum can overcome the turgor force generated by the high osmolarity of the cytoplasm. I suggest that it may not need to. Several studies in Gram-negative bacteria have shown that the periplasm is isoosmolar with the cytoplasm. Indirect evidence suggests that this is also true for Gram-positive bacteria. In this case the invagination of the septum takes place within the uniformly high osmotic pressure environment, and does not have to fight turgor pressure. A related question is how the V-shaped constriction of Gram-negative bacteria relates to the plate-like septum of Gram-positive bacteria. I collected evidence that Gram-negative bacteria have a latent capability of forming plate-like septa, and present a model in which septal division is the basic mechanism in both Gram-positive and Gram-negative bacteria. © 2017 WILEY Periodicals, Inc.

  12. Playing with Positive Feedback: External Pressure-triggering of a Star-forming Disk Galaxy

    Science.gov (United States)

    Bieri, Rebekka; Dubois, Yohan; Silk, Joseph; Mamon, Gary A.

    2015-10-01

    In massive galaxies, the currently favored method for quenching star formation is via active galactic nuclei (AGN) feedback, which ejects gas from the galaxy using a central supermassive black hole. At high redshifts however, explanation of the huge rates of star formation often found in galaxies containing AGNs may require a more vigorous mode of star formation than is attainable by simply enriching the gas content of galaxies in the usual gravitationally driven mode that is associated with the nearby universe. Using idealized hydrodynamical simulations, we show that AGN-pressure-driven star formation potentially provides the positive feedback that may be required to generate the accelerated star formation rates observed in the distant universe.

  13. Peak expiratory flow rate (PEFR) among Nuclear Fuel Complex (NFC) employees

    International Nuclear Information System (INIS)

    Vijay Rao, J.; Venkaiah, K.; Mohan Rao, N.

    2010-01-01

    At Nuclear Fuel Complex (NFC), employees are exposed to ammonia, hydrofluoric acid, acetone, etc., which are respiratory toxicants and inhalation of these pollutants may produce irritation and obstruction in airways. Due to nature of their occupation, tradesman working in plants are having longer duration of exposure (LDE) and others, such as supervisors, scientific officers, helpers, etc., that occasionally visit plants are having shorter duration of exposure (SDE) to these pollutants. The peak expiratory flow rate (PEFR) is an index to diagnose obstruction in larger airways and this is metered with mini peak flow meter among 835 NFC employees. Using ANOVA test, PEFR value was compared according to age and smoking. The value was compared between LDE and SDE employees according to smoking and duration of employment. The multiple regression equation for prediction of PEFR was developed. Age, smokers and higher duration of LDE employees demonstrated significantly lower PEFR value. In comparison to 10 year duration, 30 and above year duration of employment, LDE employees showed a higher decline in PEFR, that is 95 L (17.6%) and in SDE employees, that is 41L (7.8%). This may be due to longer duration of employment of LD employees smoking prevention and follow up study is suggested. (author)

  14. Effect of changes in PCO2 and body positions on intraocular pressure during general anaesthesia.

    Science.gov (United States)

    Hvidberg, A; Kessing, S V; Fernandes, A

    1981-08-01

    Elevated arterial carbon dioxide tension, induced by the administration of CO2 via the respiratory air or by hypoventilation, entailed a gradual increase in the IOP in patients without eye diseases under general anaesthesia. A sudden cessation of CO2 administration or hyperventilation caused such a rapid, simultaneous fall in IOP to values below the initial level that the pressure variations must be of vascular nature, presumably related to changes in choroidal blood volume. The above-mentioned procedures always cause a change in the central venous pressure (CVP) simultaneously with the IOP changes. Alterations of the CVP induced by hydrostatic factors in postural changes, placing the head 15 degrees above or below the horizontal level while keeping the PaCO2 constant, caused IOP changes of the same configuration and magnitude as described above. It is concluded, therefore, that presumably the CO2-conditioned IOP changes are due predominantly to changes in central venous pressure, being one link in a CO2-conditioned action upon the general circulation, entailing passive secondary changes in the choroidal venous blood volume and thereby an influence upon the IOP. On the basis of the present results it appears rational to recommend hyperventilation to keep the PaCO2 between 25 and 30 mm and a 15 degree anti-Trendelenburg position in operations on the eye under general anaesthesia, since both procedures afford a low central venous pressure and consequently a low pressure in the posterior segment of the eye, with its attendant advantages as regards vitreous complications and the insertion of intraocular lenses. Owing to the risk of an unacceptable fall in BP in the combined procedure, a frequent checking of the BP is needed.

  15. Paradoxical reaction of blood pressure on sleep apnoea patients treated with Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    C. Chaves Loureiro

    2011-03-01

    Full Text Available Introduction: Obstructive Sleep Apnoea Syndrome (OSAS patients may develop hypertension and Positive Airway Pressure (PAP is an effective treatment in blood pressure (BP control. Objectives: Analyse a hypertensive OSAS population with unexpected BP rise after PAP usage and verify correlations between BP rise, either with OSAS severity index or nocturnal ventilatory support compliance. Methods: Descriptive, retrospective analysis of 30 patients with PAP treated OSA, for one year, on average, and with previous controlled hypertension, who developed a rise in BP, defined as augmentation of > 5 mmHg in systolic (SBP and/or diastolic BP (DBP, after PAP usage. Co-relational analysis of BP increase, with OSAS severity indexes and therapy compliance, using Pearson coefficient. Results: Of 508 consecutive patients followed in our Department, treated with nocturnal ventilatory support, 30 evolved with BP rise after initiating treatment (age 58 ± 10.8 years; Apnoea-Hypopnoea Index [AHI], 46.1 ± 18.68. After PAP usage, mean blood pressure (MBP, Systolic BP (SBP and Diastolic BP (DBP variation was 16 ± 15 mmHg, 20 ± 25 mmHg and 6 ± 19.4 mmHg, respectively. No patient showed significant BMI increase. Epworth Sleepiness Scale (ESS value decreased 8.9 ± 5.48 points. MBP, SBP and DBP variations were not correlated with P90/P95, residual AHI, leaks or PAP compliance. Conclusions: No specific characteristics were identified in the group who developed a rise in BP with PAP usage. No correlations were found between rises in BP and OSAS severity indexes or PAP compliance. Neither BMI nor variation in wakefulness status explained the rise in BP. Studies relate polymorphisms of b1-adrenoreceptors with different BP responses to ventilatory support. More studies are needed to clarify the cause of this paradoxical response. Resumo: Introdução: Doentes com síndrome de Apneia Obstrutiva do Sono (SAOS podem desenvolver hipertensão arterial (HTA sendo a

  16. A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods.

    Science.gov (United States)

    Hajiaghaei, Behnam; Ebrahimi, Ismail; Kamyab, Mojtaba; Saeedi, Hassan; Jalali, Maryam

    2016-01-01

    Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting methods. Our hypothesis was that the casts prepared by air pressure method have less volume and are more comfortable than those prepared by weight bearing method. Fifteen transtibial unilateral amputees participated in the study. Two weight bearing and air pressure casting methods were utilized for their residual limbs. The diameters and circumferences of various areas of the residual limbs and positive casts were compared. The volumes of two types of casts were measured by a volumeter and compared. Visual Analogue Scale (VAS) was used to measure the sockets fit comfort. Circumferences at 10 and 15 cm below the patella on the casts were significantly smaller in air pressure casting method compared to the weight bearing method (p=0.00 and 0.01 respectively). The volume of the cast in air pressure method was lower than that of the weight bearing method (p=0.006). The amputees found the fit of the sockets prepared by air pressure method more comfortable than the weight bearing sockets (p=0.015). The air pressure casting reduced the circumferences of the distal portion of residual limbs which has more soft tissue and because of its snug fit it provided more comfort for amputees, according to the VAS measurements.

  17. Acute lung injury and acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Ragaller Maximillian

    2010-01-01

    Full Text Available Every year, more information accumulates about the possibility of treating patients with acute lung injury or acute respiratory distress syndrome with specially designed mechanical ventilation strategies. Ventilator modes, positive end-expiratory pressure settings, and recruitment maneuvers play a major role in these strategies. However, what can we take from these experimental and clinical data to the clinical practice? In this article, we discuss substantial options of mechanical ventilation together with some adjunctive therapeutic measures, such as prone positioning and inhalation of nitric oxide.

  18. Evaluation of image quality and patient safety: paired inspiratory and expiratory MDCT assessment of tracheobronchomalacia in paediatric patients under general anaesthesia with breath-hold technique

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Bastos, Maria d' Almeida; Stark, Cynthia; Carrier, Maureen; Zurakowski, David; Mason, Keira P.

    2012-01-01

    The purpose of our investigation was to evaluate image quality and patient safety in infants and young children who required general anaesthesia with breath-hold technique for paired inspiratory and expiratory multidetector CT (MDCT) assessment of tracheobronchomalacia (TBM). Our hospital's institutional review board approved the review of radiological and clinical data of a consecutive series of 20 paediatric patients who underwent MDCT under general anaesthesia with breath-hold technique for evaluation of TBM from May 2006 to December 2008. For each MDCT study, two fellowship-trained paediatric radiologists reviewed the inspiratory and expiratory MDCT images in an independent, randomised and blinded fashion for the presence of motion artefact at three anatomic levels (upper, middle and lower central airways). The clinical history and anaesthesia outcome, including the occurrence of any adverse events during or following the MDCT examinations until discharge, were also reviewed and recorded. The study population consisted of 20 infants and young children (13 boys/seven girls, mean age 1.7 ± 1.4 years, age range 11 days to 4 years). The imaging quality of all 20 MDCT studies was diagnostic with no motion artefact in 16 studies (80%) and minimal motion artefact in the remaining four studies (20%). Minor adverse events occurred in three patients (15%) that included one patient (5%) with a brief (<60 s) oxygen desaturation during MDCT study, which resolved with oxygen, and two patients (5%) with either a brief (<60 s) oxygen desaturation (n = 1, 5%) or cough (n = 1, 5%) during recovery period, which were completely resolved with oxygen and dexamethasone, respectively. Diagnostic quality paired inspiratory and expiratory MDCT imaging with breath-hold technique can be safely performed in infants and young children under general anaesthesia for evaluation of TBM.

  19. The effect of lateral decubitus position on nocturnal intraocular pressure over a habitual 24-hour period in healthy adults.

    Science.gov (United States)

    Hao, Jie; Zhen, Yi; Wang, Hao; Yang, Diya; Wang, Ningli

    2014-01-01

    To investigate the effect of lateral decubitus position (LDP) on nocturnal intraocular pressure (IOP) and the effect of LDP on 24-hour habitual IOP pattern in healthy subjects. Intraocular pressure was measured every 2-hours using an Accupen Applanation Tonometer (Accutome, USA). During the diurnal period (7:30 am, 9:30 am, 11:30 am, 1:30 pm, 3:30 pm, 5:30 pm, 7:30 pm, and 9:30 pm), IOP was measured in the sitting position under bright light (500-1000 lux) after the subjects had been seated for 5 min. The nocturnal IOP was measured in the supine position, right LDP, and left LDP, with randomized sequences, under dim light (hour habitual IOP patterns were obtained according to the nocturnal position (supine, right LDP and left LDP) for either eye. Phour period, the effect of LDP on habitual IOP pattern was not statistically significant, although the mean nocturnal IOP and the diurnal-nocturnal IOP change for the right and the left eye in the LDP pattern was slightly higher than that in the sitting-supine pattern. Significant nocturnal IOP differences existed between the dependent eye and the supine, but did not occur consistently for all time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant in healthy subjects.

  20. Two-Dimensional Electron Density Measurement of Positive Streamer Discharge in Atmospheric-Pressure Air

    Science.gov (United States)

    Inada, Yuki; Ono, Ryo; Kumada, Akiko; Hidaka, Kunihiko; Maeyama, Mitsuaki

    2016-09-01

    The electron density of streamer discharges propagating in atmospheric-pressure air is crucially important for systematic understanding of the production mechanisms of reactive species utilized in wide ranging applications such as medical treatment, plasma-assisted ignition and combustion, ozone production and environmental pollutant processing. However, electron density measurement during the propagation of the atmospheric-pressure streamers is extremely difficult by using the conventional localized type measurement systems due to the streamer initiation jitters and the irreproducibility in the discharge paths. In order to overcome the difficulties, single-shot two-dimensional electron density measurement was conducted by using a Shack-Hartmann type laser wavefront sensor. The Shack-Hartmann sensor with a temporal resolution of 2 ns was applied to pulsed positive streamer discharges generated in an air gap between pin-to-plate electrodes. The electron density a few ns after the streamer initiation was 7*1021m-3 and uniformly distributed along the streamer channel. The electron density and its distribution profile were compared with a previous study simulating similar streamers, demonstrating good agreement. This work was supported in part by JKA and its promotion funds from KEIRIN RACE. The authors like to thank Mr. Kazuaki Ogura and Mr. Kaiho Aono of The University of Tokyo for their support during this work.

  1. Pulmonary edema and lung injury after severe laryngospasm

    International Nuclear Information System (INIS)

    Saddiqi, R.; Khalique, K.

    2006-01-01

    A young male with no pre-operative medical illness underwent corrective surgery for a deviated nasal septum under general anesthesia. At the end of surgery, patient was extubated but went into severe laryngospasm that did not improve with gentle Intermittent Positive Pressure Ventilation (IPPV) and small dose of Suxamethonium. As the situation worsened and patient developed severe bradycardia and de-saturation, re-intubation was done that revealed pink froth in the endotracheal tube. His portable chest X-ray was suggestive of non-cardiogenic pulmonary edema. With an overnight supportive treatment, using mechanical ventilation with Positive End- Expiratory Pressure (PEEP), morphine infusion and frusemide, patient improved and was subsequently weaned off from ventilator. (author)

  2. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Yanagawa, Noriyuki, E-mail: yanagawa@ho.chiba-u.ac.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakurai, Yoriko, E-mail: yoliri@nifty.com [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sato, Misuzu, E-mail: mis_misuzu@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Iesato, Ken, E-mail: iesato_k@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Terada, Jiro, E-mail: jirotera@chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Suzuki, Yoichi, E-mail: ysuzuki@faculty.chiba-u.jp [Department of public Health, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan)

    2013-10-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm{sup 2} as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers.

  3. The Effect of Swimming Activity on Lung Function Parameters Among Smoking and Non-Smoking Youth – Research Extended

    Directory of Open Access Journals (Sweden)

    Michalak Katarzyna

    2015-12-01

    Full Text Available Purpose. The purpose of this study was to evaluate the effect of regular swimming activity on the respiratory system of smokers and non-smokers. Methods. The study included 196 students, aged 19 to 24 years, attending weekly swimming classes. All students underwent pulmonary function testing before and after participating in a swimming program for 10 months. Measurements included forced vital capacity (FVC, forced expiratory volume in one second (FEV1, and peak expiratory flow (PEF. Maximal inspiratory and expiratory pressure at the mouth (PImax, PEmax and the percentage carboxyhemoglobin level in blood (%CoHb were also measured. Results. After 10 months of regular swimming activity the values of FVC, PEF, MIP and MEP increased in the non-smoking as well as in the smoking group, while the FEV1 increased only among smokers. The percentage of CoHB level in the blood decreased in both groups. Conclusions. The study confirmed the positive effect of swimming on respiratory system function and the importance of promoting physical activity such as swimming among cigarette smokers as well as non-smokers.

  4. Peak expiratory flow rate in healthy rural school going children (5-16 years) of bellur region for construction of nomogram.

    Science.gov (United States)

    Cb, Manjunath; Sc, Kotinatot; Babu, Manjunatha

    2013-12-01

    Peak Expiratory Flow Rate (PEFR) recording is an essential measure in the management and evaluation of asthmatic children.It is helpful in monitoring disease progression and response to treatment. The PEFR can be measured by a simple instrument-peak expiratory flow meter. To construct nomogram of PEFR in healthy rural school going children from Mandya district of Karnataka state, India and to use these nomograms for comparison with that of children with obstructive lung diseases for this region. The study was conducted on Healthy rural school going children, both boys and girls between the age group of 5-16 years. For the determination of PEFR we used Mini Wright Peak Flow Meter. At three time measurement, the highest value of PEFR was recorded. Formula for prediction of PEFR was estimated by linear regression analysis after the correlation of PEFR with age and height for both boys and girls. PEFR was measured in 1028 children aged 5 to 16 years by using Wright's mini peak flow meter. Prediction equations were derived for PEFR with height in boys and girls. Normograms were plotted based on the observed values of PEFR in the study population. Significant linear correlation was seen of PEFR with height in boys (paffected by regional, environmental and anthropometric factors. Hence, it is necessary to have regional reference values for children. Among different factors affecting PEFR, height correlates better with PEFR than weight and sex. Hence nomograms constructed can be used for this region.

  5. A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity

    Directory of Open Access Journals (Sweden)

    Sermin Börekçi

    2017-04-01

    Full Text Available Background: Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction. Aims: To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction and reflects hyperinflation and air trapping. Study Design: Retrospective cross-sectional study. Methods: Retrospective assessment of a total of 1110 cases who underwent body plethysmographic lung volume estimations between a time span from 2005 to 2012. Patients were assigned into two groups: firstly by FEV1/FVC (FEV1/FVC <70% vs. FEV1/FVC ≥70%; secondly by FEV3/FVC < lower limits of normal (LLN (FEV3/FVC < LLN vs. FEV3/FVC ≥ LLN. Spirometric indices and lung volumes measured by whole-body plethysmography were compared in groups. Also the correlation of spirometric indices with measured lung volumes were assessed in the whole-study population and in subgroups stratified according to FEV1/FVC and FEV3/FVC. Results: Six hundred seven (54.7% were male and 503 (45.3% were female, with a mean age of 52.5±15.6 years. Mean FEV3/FVC and 1-FEV3/FVC were 87.05%, 12.95%, respectively. The mean 1-FEV3/FVC was 4.9% in the FEV1/FVC ≥70% group (n=644 vs. 24.1% in the FEV1/FVC <70% group (n=466. A positive correlation was found between 1-FEV3/FVC and residual volume (r=0.70; p<0.0001, functional residual capacity-pleth (r=0.61; p<0.0001, and total lung capacity (r=0.47; p<0.0001. 1-FEV3/FVC was negatively correlated with forced expiratory flow25-75 (r=−0.84; p<0.0001. The upper limit of 95% confidence interval for 1-FEV3/FVC was 13.7%. 1-FEV3/FVC showed significant correlations with parameters of air trapping and hyperinflation measured by whole-body plethysmography. Importantly, these correlations were higher in study participants with FEV1/FVC <70% or FEV3/FVC

  6. Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

    Science.gov (United States)

    Thille, Arnaud W; Bertholon, Jean-François; Becquemin, Marie-Hélène; Roy, Monique; Lyazidi, Aissam; Lellouche, François; Pertusini, Esther; Boussignac, Georges; Maître, Bernard; Brochard, Laurent

    2011-10-01

    A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. First we assessed the relationship between flow and pressure generated in the mask with the Boussignac CPAP system. Next we measured the inspired-gas humidity during CPAP, with several humidification strategies, in 9 healthy volunteers. We then measured the bronchodilator aerosol particle size during CPAP, with and without heat-and-moisture exchanger, in a bench study. Finally, in 7 patients with acute respiratory failure and airway obstruction, we measured work of breathing and gas exchange after a β(2)-agonist bronchodilator aerosol (terbutaline) delivered during CPAP or via standard nebulization. Optimal humidity was obtained only with the heat-and-moisture exchanger or heated humidifier. The heat-and-moisture exchanger had no influence on bronchodilator aerosol particle size. Work of breathing decreased similarly after bronchodilator via either standard nebulization or CPAP, but P(aO(2)) increased significantly only after CPAP aerosol delivery. CPAP bronchodilator delivery decreases the work of breathing as effectively as does standard nebulization, but produces a greater oxygenation improvement in patients with airway obstruction. To optimize airway humidification, a heat-and-moisture exchanger could be used with the Boussignac CPAP system, without modifying aerosol delivery.

  7. Muscle activation and estimated relative joint force during running with weight support on a lower-body positive pressure treadmill

    DEFF Research Database (Denmark)

    Jensen, Bente Rona; Hovgaard-Hansen, Line; Cappelen, Katrine Louise

    2016-01-01

    Running on a lower-body positive pressure (LBPP) treadmill allows effects of weight support on leg muscle activation to be assessed systematically, and has the potential to facilitate rehabilitation and prevent overloading. The aim was to study the effect of running with weight support on leg mus...

  8. Prediction of Spirometric Forced Expiratory Volume (FEV1) Data Using Support Vector Regression

    Science.gov (United States)

    Kavitha, A.; Sujatha, C. M.; Ramakrishnan, S.

    2010-01-01

    In this work, prediction of forced expiratory volume in 1 second (FEV1) in pulmonary function test is carried out using the spirometer and support vector regression analysis. Pulmonary function data are measured with flow volume spirometer from volunteers (N=175) using a standard data acquisition protocol. The acquired data are then used to predict FEV1. Support vector machines with polynomial kernel function with four different orders were employed to predict the values of FEV1. The performance is evaluated by computing the average prediction accuracy for normal and abnormal cases. Results show that support vector machines are capable of predicting FEV1 in both normal and abnormal cases and the average prediction accuracy for normal subjects was higher than that of abnormal subjects. Accuracy in prediction was found to be high for a regularization constant of C=10. Since FEV1 is the most significant parameter in the analysis of spirometric data, it appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.

  9. Sleep architecture, insulin resistance and the nasal cycle: Implications for positive airway pressure therapy

    Directory of Open Access Journals (Sweden)

    Catherine A.P. Crofts

    2018-03-01

    Full Text Available Background: The global pandemic of metabolic disease is worsening. The metabolic theory of obesity proposes that hormonal changes, especially hyperinsulinaemia, precede metabolic disease development. Although quality sleep is recognised as a key factor for good health, less is known about disrupted sleep as a risk factor for hyperinsulinaemia.   Aim: To explore the relationship between sleep, especially sleep architecture and the nasal cycle, on insulin secretion in obstructive sleep apnoea (OSA with comorbid metabolic disease. This review includes a discussion of the potential role of Rest-Activity-Cycler positive airway pressure (RACer-PAP, a novel non-pharmacological OSA treatment strategy.   Methods: A narrative review of all the relevant papers known to the authors was conducted. This review also included results from a polysomnographic sleep clinic pilot study (n = 3 comparing sleep efficiency of RACer-PAP to nasal continuous positive airways pressure (n-CPAP in OSA patients.   Results: Metabolic disease is strongly associated with disturbed sleep. Sleep architecture influences cerebral hormonal secretion, lateral shifts in the autonomic nervous system and nasal airflow dominance. Disturbed sleep shortens short-wave sleep periods, decreasing insulin sensitivity and glucose tolerance. Improvements to metabolic function during n-CPAP treatment are inconsistent. If RACer-PAP demonstrates superior effects on sleep architecture and autonomic function, it may offer advantages in OSA patients with comorbid metabolic disease.   Conclusion: Improving sleep architecture by maintaining the nasal cycle proposes a novel non-pharmacological treatment paradigm for treating OSA with comorbid metabolic disease. Research is required to demonstrate if RACer-PAP therapy influences whole night sleep architecture, sympathovagal balance and markers of metabolic disease.

  10. Expiratory CT in cigarette smokers: correlation between areas of decreased lung attenuation, pulmonary function tests and smoking history

    Energy Technology Data Exchange (ETDEWEB)

    Verschakelen, J.A.; Scheinbaum, K.; Bogaert, J.; Baert, A.L. [Department of Radiology, University Hospitals, Leuven (Belgium); Demedts, M.; Lacquet, L.L. [Department of Pneumology, University Hospitals, Leuven (Belgium)

    1998-10-01

    The aim of this study was to determine the correlation between cigarette-smoke-related bronchial disease and air trapping as assessed by expiratory high-resolution CT (HRCT) scans. Thirty healthy subjects (11 non-smokers, 7 ex-smokers for > 2 years, 12 current smokers; age range 35-55 years) with a smoking history between 0 and 28.5 pack-years underwent pulmonary function tests (PFT) and HRCT in inspiration and expiration in supine and prone position. The extent of air trapping was scored in ventral and dorsal aspects of the upper, middle and lower lung portions. In 24 subjects (7 non-smokers, 7 ex-smokers, 10 current smokers) areas of focal air trapping were found, and were present significantly more often in dependent lung portions (p < 0.05) compared with non-dependent portions. No significant differences were found between apical and basal lung zones. Scores of focal air trapping were not significantly different between smokers and ex-smokers, but were significantly lower (p < 0.05) in non-smokers and showed a significant (p < 0.0005) correlation with pack-years. The degree of air trapping was also associated with several lung function tests, especially RV, DLCO, FRC, FEV1 and FEV1/VC. Air trapping is seen in smokers with normal PFT and correlates with the severity of the smoking history, independently of current smoking status. (orig.) (orig.) With 4 figs., 4 tabs., 59 refs.

  11. Learning to breathe and sing: development of respiratory-vocal coordination in young songbirds.

    Science.gov (United States)

    Veit, Lena; Aronov, Dmitriy; Fee, Michale S

    2011-10-01

    How do animals with learned vocalizations coordinate vocal production with respiration? Songbirds such as the zebra finch learn their songs, beginning with highly variable babbling vocalizations known as subsong. After several weeks of practice, zebra finches are able to produce a precisely timed pattern of syllables and silences, precisely coordinated with expiratory and inspiratory pulses (Franz M, Goller F. J Neurobiol 51: 129-141, 2002). While respiration in adult song is well described, relatively little is known about respiratory patterns in subsong or about the processes by which respiratory and vocal patterns become coordinated. To address these questions, we recorded thoracic air sac pressure in juvenile zebra finches prior to the appearance of any consistent temporal or acoustic structure in their songs. We found that subsong contains brief inspiratory pulses (50 ms) alternating with longer pulses of sustained expiratory pressure (50-500 ms). In striking contrast to adult song, expiratory pulses often contained multiple (0-8) variably timed syllables separated by expiratory gaps and were only partially vocalized. During development, expiratory pulses became shorter and more stereotyped in duration with shorter and fewer nonvocalized parts. These developmental changes eventually resulted in the production of a single syllable per expiratory pulse and a single inspiratory pulse filling each gap, forming a coordinated sequence similar to that of adult song. To examine the role of forebrain song-control nuclei in the development of respiratory patterns, we performed pressure recordings before and after lesions of nucleus HVC (proper name) and found that this manipulation reverses the developmental trends in measures of the respiratory pattern.

  12. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Elinaldo da Conceição dos Santos

    2015-04-01

    Discussion: Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications.

  13. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery.

    Science.gov (United States)

    Hemmes, Sabrine N T; Severgnini, Paolo; Jaber, Samir; Canet, Jaume; Wrigge, Hermann; Hiesmayr, Michael; Tschernko, Edda M; Hollmann, Markus W; Binnekade, Jan M; Hedenstierna, Göran; Putensen, Christian; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2011-05-06

    Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia >2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure (PEEP) and repeated recruitment maneuvers; the "open lung strategy", protects against post-operative pulmonary complications is uncertain. The present study aims at comparing a protective mechanical ventilation strategy with a conventional mechanical ventilation strategy during general anesthesia for abdominal non-laparoscopic surgery. The PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure ("PROVHILO") trial is a worldwide investigator-initiated multicenter randomized controlled two-arm study. Nine hundred patients scheduled for non-laparoscopic abdominal surgery at high or intermediate risk for post-operative pulmonary complications are randomized to mechanical ventilation with the level of PEEP at 12 cmH(2)O with recruitment maneuvers (the lung-protective strategy) or mechanical ventilation with the level of PEEP at maximum 2 cmH(2)O without recruitment maneuvers (the conventional strategy). The primary endpoint is any post-operative pulmonary complication. The PROVHILO trial is the first randomized controlled trial powered to investigate whether an open lung mechanical ventilation strategy in short-term mechanical ventilation prevents against postoperative pulmonary complications. ISRCTN: ISRCTN70332574.

  14. Deep breathing exercises performed 2 months following cardiac surgery: a randomized controlled trial.

    Science.gov (United States)

    Westerdahl, Elisabeth; Urell, Charlotte; Jonsson, Marcus; Bryngelsson, Ing-Liss; Hedenström, Hans; Emtner, Margareta

    2014-01-01

    Postoperative breathing exercises are recommended to cardiac surgery patients. Instructions concerning how long patients should continue exercises after discharge vary, and the significance of treatment needs to be determined. Our aim was to assess the effects of home-based deep breathing exercises performed with a positive expiratory pressure device for 2 months following cardiac surgery. The study design was a prospective, single-blinded, parallel-group, randomized trial. Patients performing breathing exercises 2 months after cardiac surgery (n = 159) were compared with a control group (n = 154) performing no breathing exercises after discharge. The intervention consisted of 30 slow deep breaths performed with a positive expiratory pressure device (10-15 cm H2O), 5 times a day, during the first 2 months after surgery. The outcomes were lung function measurements, oxygen saturation, thoracic excursion mobility, subjective perception of breathing and pain, patient-perceived quality of recovery (40-Item Quality of Recovery score), health-related quality of life (36-Item Short Form Health Survey), and self-reported respiratory tract infection/pneumonia and antibiotic treatment. Two months postoperatively, the patients had significantly reduced lung function, with a mean decrease in forced expiratory volume in 1 second to 93 ± 12% (P< .001) of preoperative values. Oxygenation had returned to preoperative values, and 5 of 8 aspects in the 36-Item Short Form Health Survey were improved compared with preoperative values (P< .01). There were no significant differences between the groups in any of the measured outcomes. No significant differences in lung function, subjective perceptions, or quality of life were found between patients performing home-based deep breathing exercises and control patients 2 months after cardiac surgery.

  15. A historical perspective on ventilator management.

    Science.gov (United States)

    Shapiro, B A

    1994-02-01

    Paralysis via neuromuscular blockade in ICU patients requires mechanical ventilation. This review historically addresses the technological advances and scientific information upon which ventilatory management concepts are based, with special emphasis on the influence such concepts have had on the use of neuromuscular blocking agents. Specific reference is made to the scientific information and technological advances leading to the newer concepts of ventilatory management. Information from > 100 major studies in the peer-reviewed medical literature, along with the author's 25 yrs of clinical experience and academic involvement in acute respiratory care is presented. Nomenclature related to ventilatory management is specifically defined and consistently utilized to present and interpret the data. Pre-1970 ventilatory management is traced from the clinically unacceptable pressure-limited devices to the reliable performance of volume-limited ventilators. The scientific data and rationale that led to the concept of relatively large tidal volume delivery are reviewed in the light of today's concerns regarding alveolar overdistention, control-mode dyssynchrony, and auto-positive end-expiratory pressure. Also presented are the post-1970 scientific rationales for continuous positive airway pressure/positive end-expiratory pressure therapy, avoidance of alveolar hyperxia, and partial ventilatory support techniques (intermittent mandatory ventilation/synchronized intermittent mandatory ventilation). The development of pressure-support devices is discussed and the capability of pressure-control techniques is presented. The rationale for more recent concepts of total ventilatory support to avoid ventilator-induced lung injury is presented. The traditional techniques utilizing volume-preset ventilators with relatively large tidal volumes remain valid and desirable for the vast majority of patients requiring mechanical ventilation. Neuromuscular blockade is best avoided in these

  16. Decreased peak expiratory flow in pediatric passive smokers

    Directory of Open Access Journals (Sweden)

    Fitri Yanti

    2011-08-01

    Full Text Available Background Indonesia ranks fifth among countries with the highest aggregate levels of tobacco consumption in the world. Infants and children exposed to environmental tobacco smoke have increased rates of asthma, respiratory and ear infections, as well as reduced lung function. The effects of tobacco smoke exposure on lung function in children have been reported to be dependent on the source of smoke and the length and dose of exposure. Lung function may also be affected by a child’s gender and asthma status. Objective To compare peak expiratory flow (PEF in pediatric passive smokers to that of children not exposed to second hand smoke, and to define factors that may affect PEF in passive smokers. Methods In August 2009 we conducted a cross-sectional study at an elementary school in the Langkat district. Subjects were aged 6 to 12 years, and divided into two groups: passive smokers and those not exposed to secondhand smoke. Subjects’ PEFs were measured with a Mini-Wright peak flow meter. Measurements were performed in triplicate with the highest value recorded as the PEF. Demographic data including age, sex, weight, height, family income, parental education levels and occupations were obtained through questionnaires. Results Of the 170 participants, 100 were passive smokers and 70 were not exposed to secondhand smoke. Age distribution, weight and height were similar in both groups. We observed a significant difference in PEFs between the group of passive smokers and the group not exposed to secondhand smoke, 211.3 L/minute (SD 61.08 and 242.7 L/minute (SD 77.09, respectively (P < 0.005. The number of years of exposure to smoke (P = 0.079 and the number of cigarettes smoked daily in the household (P = 0.098 did not significantly influence PEF. Conclusion The PEF in pediatric passive smokers was significantly lower than that of children not exposed to secondhand smoke. PEF in passive smokers was not influenced by the number of years of smoke

  17. "THE EVALUATION OF THE POSSIBLE EFFECT OF POSITIVE END EXPIRATORY PRESSURE (PEEP ON PHARMACOKINETICS OF PHENYTOIN IN PATIENTS WITH ACUTE BRAIN INJURY UNDER MECHANICAL VENTILATION."

    Directory of Open Access Journals (Sweden)

    "Elham Hadidi

    2005-04-01

    Full Text Available Positive ventilation has shown to have an influence on pharmacokinetic and disposition of some drugs.Beacause phenytoin with a narrow therapautic range, is the most commonly used drug for prophylaxis and treatment of early seizures after acute brain injuries, in the present study the effect of short term PEEP (5-10 cm H2O for at least 8 hours on phenytoin serum concentration and pharmacokinetic parameters such as Vmax and clearance in brain injured patients under mechanical ventilation was examined. Ten patients with moderate to severe acute brain injury who were placed on mechanical ventilation with an initial PEEP level of 0-5 cm H2O were included in the study. Patients received phenytoin loading dose of 15 mg/kg followed by a maintenance daily dose of 3-7 mg/kg initiated within 12 hours of loading dose. Sampels were taken on two different occasions before and after PEEP elevation. Total phenytoin serum concentrations were determined by HPLC method. A time invarient Michaelis-Menten pharmacokinetic model was used to calculate Vmax and clearance for each patient.Derrived variables were calculated as follows: Vmax, 3.5-6.8 and 3.7-8.2 mg/kg/day; Clearance, 0.1-0.7 and 0.1-1.2 l/kg/day (before and after PEEP elevation, respectively. Our data have shown a wide range of variability (2.6-32.5 mg/l in phenytoin serum concentrations. There were no statistically significant differences in the measured total concentrations (p=0.721 and calculated Vmax and clearance (p=0.285before and after PEEP elevation. Administration of fluid and inotropic agents, limitation in application of higher levels of PEEP and drug interactions, shall be considered as possible explanations for these findings.

  18. [Effect of oxygen tubing connection site on percutaneous oxygen partial pressure and percutaneous carbon dioxide partial pressure in patients with chronic obstructive pulmonary disease during noninvasive positive pressure ventilation].

    Science.gov (United States)

    Mi, S; Zhang, L M

    2017-04-12

    Objective: We evaluated the effects of administering oxygen through nasal catheters inside the mask or through the mask on percutaneous oxygen partial pressure (PcO(2))and percutaneous carbon dioxide partial pressure (PcCO(2)) during noninvasive positive pressure ventilation (NPPV) to find a better way of administering oxygen, which could increase PcO(2) by increasing the inspired oxygen concentration. Methods: Ten healthy volunteers and 9 patients with chronic obstructive pulmonary disease complicated by type Ⅱ respiratory failure were included in this study. Oxygen was administered through a nasal catheter inside the mask or through the mask (oxygen flow was 3 and 5 L/min) during NPPV. PcO(2) and PcCO(2) were measured to evaluate the effects of administering oxygen through a nasal catheter inside the mask or through the mask, indirectly reflecting the effects of administering oxygen through nasal catheter inside the mask or through the mask on inspired oxygen concentration. Results: Compared to administering oxygen through the mask during NPPV, elevated PcO(2) was measured in administering oxygen through the nasal catheter inside the mask, and the differences were statistically significant ( P 0.05). Conclusion: Administering oxygen through a nasal catheter inside the mask during NPPV increased PcO(2) by increasing the inspired oxygen concentration but did not increase PcCO(2). This method of administering oxygen could conserve oxygen and be suitable for family NPPV. Our results also provided theoretical basis for the development of new masks.

  19. High tidal volume ventilation in infant mice.

    Science.gov (United States)

    Cannizzaro, Vincenzo; Zosky, Graeme R; Hantos, Zoltán; Turner, Debra J; Sly, Peter D

    2008-06-30

    Infant mice were ventilated with either high tidal volume (V(T)) with zero end-expiratory pressure (HVZ), high V(T) with positive end-expiratory pressure (PEEP) (HVP), or low V(T) with PEEP. Thoracic gas volume (TGV) was determined plethysmographically and low-frequency forced oscillations were used to measure the input impedance of the respiratory system. Inflammatory cells, total protein, and cytokines in bronchoalveolar lavage fluid (BALF) and interleukin-6 (IL-6) in serum were measured as markers of pulmonary and systemic inflammatory response, respectively. Coefficients of tissue damping and tissue elastance increased in all ventilated mice, with the largest rise seen in the HVZ group where TGV rapidly decreased. BALF protein levels increased in the HVP group, whereas serum IL-6 rose in the HVZ group. PEEP keeps the lungs open, but provides high volumes to the entire lungs and induces lung injury. Compared to studies in adult and non-neonatal rodents, infant mice demonstrate a different response to similar ventilation strategies underscoring the need for age-specific animal models.

  20. The effect of obstructive sleep apnea and treatment with continuous positive airway pressure on stroke rehabilitation: rationale, design and methods of the TOROS study

    NARCIS (Netherlands)

    Aaronson, Justine A.; van Bennekom, Coen A. M.; Hofman, Winni F.; van Bezeij, Tijs; van den Aardweg, Joost G.; Groet, Erny; Kylstra, Wytske A.; Schmand, Ben A.

    2014-01-01

    Obstructive sleep apnea is a common sleep disorder in stroke patients. Obstructive sleep apnea is associated with stroke severity and poor functional outcome. Continuous positive airway pressure seems to improve functional recovery in stroke rehabilitation. To date, the effect of continuous positive

  1. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  2. All-cause mortality from obstructive sleep apnea in male and female patients with and without continuous positive airway pressure treatment

    DEFF Research Database (Denmark)

    Jennum, Poul; Tønnesen, Philip; Ibsen, Rikke

    2015-01-01

    BACKGROUND: More information is needed about the effect on mortality of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA), especially in women. METHODS: We employed a historical cohort study design, using data from 25,389 patients with a diagnosis of OSA...

  3. Bilateral diaphragmatic paralysis after cardiac surgery: ventilatory assistance by nasal mask continuous positive airway pressure.

    Science.gov (United States)

    Hoch, B; Zschocke, A; Barth, H; Leonhardt, A

    2001-01-01

    The case of an 8-month-old boy with bilateral diaphragmatic paralysis after surgical reoperation for congenital heart disease is presented. In order to avoid repeated intubation and long-term mechanical ventilation or tracheotomy, we used nasal mask continuous positive airway pressure (CPAP) as an alternative method for assisted ventilation. Within 24 hours the boy accepted the nasal mask and symptoms such as dyspnea and sweating disappeared. Respiratory movements became regular and oxygen saturation increased. Nasal mask CPAP may serve as an alternative treatment of bilateral diaphragmatic paralysis in infants, thereby avoiding tracheotomy or long-term mechanical ventilation.

  4. Ultra-protective tidal volume: how low should we go?

    OpenAIRE

    Costa, Eduardo LV; Amato, Marcelo BP

    2013-01-01

    Applying tidal volumes of less than 6 mL/kg might improve lung protection in patients with acute respiratory distress syndrome. In a recent article, Retamal and colleagues showed that such a reduction is feasible with conventional mechanical ventilation and leads to less tidal recruitment and overdistension without causing carbon dioxide retention or auto-positive end-expiratory pressure. However, whether the compensatory increase in the respiratory rate blunts the lung protection remains une...

  5. ERGONOMIC CONSIDERATION OF THE EFFECT OF FLOUR DUST ON PEAK EXPIRATORY FLOW RATE OF BAKERS IN ABEOKUTA, OGUN STATE

    Directory of Open Access Journals (Sweden)

    Adekunle Ibrahim MUSA

    2017-06-01

    Full Text Available Flour dusts are one of the most harmful chemicals in the bakery industries which could lead to serious heart and lung diseases. This study investigated the effect of flour dust on Peak Expiratory Flow Rate of male bakers in Abeokuta, Ogun State, Nigeria with the relationship to the anthropometrical parameters. A total of One hundred Eighty (180 male participants were investigated, where ninety (90 participants were bakers and ninety (90 individuals as control group. The Peak expiratory flow rate (PEFR and anthropometrical parameters of the participant were measured using mini-Wright peak flow meter (PFM 20, OMRON and Detecto PD300MDHR (Cardinal Scale manufacturing company, USA column scale with digital height rod was used to measure body mass [kg] and height (cm respectively. The PEFR and anthropometrical parameters of the bakers and control groups were analysed using descriptive statistics and T-test with SPSS. The results showed that lower PEFR, 182.67 ± 16.34 L/min existed in bakers compared to 287.67 ± 17.02 L/min in the control study. The result also showed that a significant correlation exist between body mass, height and age (P < 0.01, PEFR, height (P < 0.05 and years of exposure (P < 0.01 of the bakers respectively. Furthermore, the results also showed that workers in the dusting and mixing of flour are at a risk of developing related pulmonary function impairment such as asthma. The study concluded that there is need to develop an effective intervention strategy, treatment seeking behaviour through awareness programs to prevent lung impairment diseases among the bakery workers.

  6. Prevention of Hypoxemia During Apnea Testing: A Comparison of Oxygen Insufflation And Continuous Positive Airway Pressure.

    Science.gov (United States)

    Kramer, Andreas H; Couillard, Philippe; Bader, Ryan; Dhillon, Peter; Kutsogiannis, Demetrios J; Doig, Christopher J

    2017-08-01

    Apnea testing is an essential step in the clinical diagnosis of brain death. Current international guidelines recommend placement of an oxygen (O 2 ) insufflation catheter into the endotracheal tube to prevent hypoxemia, but use of a continuous positive airway pressure (CPAP) valve may be more effective at limiting arterial partial pressure of O 2 (PO 2 ) reduction. We performed a multicenter study assessing consecutive apnea tests in 14 intensive care units (ICUs) in two cities utilizing differing protocols. In one city, O 2 catheters are placed and arterial blood gases (ABGs) performed at intervals determined by the attending physician. In the other city, a resuscitation bag with CPAP valve is attached to the endotracheal tube, and ABGs performed every 3-5 min. We assessed arterial PO 2 , partial pressure of carbon dioxide (PCO 2 ), pH, and blood pressure at the beginning and termination of each apnea test. Thirty-six apnea tests were performed using an O 2 catheter and 50 with a CPAP valve. One test per group was aborted because of physiological instability. There were no significant differences in the degree of PO 2 reduction (-59 vs. -32 mmHg, p = 0.72), rate of PCO 2 rise (3.2 vs. 3.9 mmHg per min, p = 0.22), or pH decline (-0.02 vs. -0.03 per min, p = 0.06). Performance of ABGs at regular intervals was associated with shorter test duration (10 vs. 7 min, p pressure decline (p = 0.006). Both methods of O 2 supplementation are associated with similar changes in arterial PO 2 and PCO 2 . Performance of ABGs at regular intervals shortens apnea test duration and may avoid excessive pH reduction and consequent hemodynamic effects.

  7. Effect of Graded Unilateral Sanding Exercise on Metabolic and Cardiopulmonary Function in the Healthy and the Hemiparetic Elderly Subjects

    OpenAIRE

    Muraki, Toshiaki

    1997-01-01

    The purpose of this study was to investigate how 18 elderly subjects with cerebral vascular accident (CVA) (14 men and 4 women) and 19 healthy elderly subjects (6 men and 13 women) would respond to a five-step graded unilateral sanding activity. Three indicators of pulmonary function such as expiratory tidal volume, respiratory rate, and expiratory volume and four indicators of cardiometabolic function such as metabolic equivalents (METS), systolic blood pressure, heart rate, and pressure rat...

  8. Sudden versus gradual pressure wean from Nasal CPAP in preterm infants: a randomized controlled trial.

    Science.gov (United States)

    Amatya, S; Macomber, M; Bhutada, A; Rastogi, D; Rastogi, S

    2017-06-01

    In preterm infants, nasal continuous positive airway pressure (NCPAP) is widely used for treatment of respiratory distress syndrome. However, the strategies for successfully weaning infants off NCPAP are still not well defined and there remains considerable variation between the methods. The objective of this study is to determine whether gradual weaning of NCPAP pressure is more successful than sudden weaning off NCPAP to room air. A randomized controlled trial was conducted in a level 3 neonatal intensive care unit on 70 preterm neonates who were born between 26 and 32 weeks gestation and required NCPAP for at least 48 h. When infants were stable on NCPAP at 0.21 FiO 2 and 5 cm H 2 O positive end expiratory pressure, neonates were randomized to the gradual wean group (reduction in pressure by 1 cm every 8 h until 3 cm H 2 0 was reached) or to sudden wean group (one time NCPAP removal to room air). The primary outcome was a success at the first trial to wean to room air. Secondary outcomes were a number of trials, and weight and postmenstrual age (PMA) at the time of successful wean. Total number of days on NCPAP and length of stay (LOS) in the hospital were also compared between the groups. Of the 70 infants included in the study, 35 were randomized to sudden group and 33 infants to gradual group (2 excluded for protocol deviation). In sudden and gradual groups, 14 and 22 infants, respectively, were weaned successfully in the first attempt (P=0.03). The infants were successfully weaned at 32.7±1.7 weeks versus 33.1±2.4 weeks (P=0.39) PMA and at a weight of 1651±290 g versus 1589±398 g (P=0.46) in the sudden and gradual groups, respectively. The total number of days on NCPAP was 27±19 days versus 32±24 days (P=0.38) and LOS was 63±25 days versus 63±22 days (P=0.99) in the sudden and gradual groups, respectively. Gradual weaning method was more successful as compared to sudden weaning method in the initial trial off NCPAP. There was no

  9. Comparison of positive-pressure, passive ultrasonic, and laser-activated irrigations on smear-layer removal from the root canal surface.

    Science.gov (United States)

    Sahar-Helft, Sharonit; Sarp, Ayşe Sena Kabaş; Stabholtz, Adam; Gutkin, Vitaly; Redenski, Idan; Steinberg, Doron

    2015-03-01

    The purpose of this study was to compare the efficacy of three irrigation techniques for smear-layer removal with 17% EDTA. Cleaning and shaping the root canal system during endodontic treatment produces a smear layer and hard tissue debris. Three irrigation techniques were tested for solution infiltration of this layer: positive-pressure irrigation, passive ultrasonic irrigation, and laser-activated irrigation. Sixty extracted teeth were divided into six equal groups; 17% EDTA was used for 60 sec irrigation of five of the groups. The groups were as follows: Group 1, treated only with ProTaper™ F3 Ni-Ti files; Group 2, positive-pressure irrigation, with a syringe; Group 3, passive ultrasonic irrigation, inserted 1 mm short of the working length; Group 4, passive ultrasonic irrigation, inserted in the upper coronal third of the root; Group 5, Er:YAG laser-activated irrigation, inserted 1 mm short of the working length; and Group 6, Er:YAG laser-activated irrigation, inserted in the upper coronal third of the root. Scanning electron microscopy showed that the smear layer is removed most efficiently using laser-activated irrigation at low energy with 17% EDTA, inserted either at the working length or only in the coronal upper third of the root. Amounts of Ca, P, and O were not significantly different on all treated dentin surfaces. Smear-layer removal was most effective when the root canals were irrigated using Er:YAG laser at low energy with 17% EDTA solution. Interestingly, removal of the smear layer along the entire canal was similar when the laser was inserted in the upper coronal third and at 1 mm short of the working length of the root canal. This effect was not observed with the ultrasonic and positive-pressure techniques.

  10. Finite element modeling for predicting the contact pressure between a foam mattress and the human body in a supine position.

    Science.gov (United States)

    Lee, Wookjin; Won, Byeong Hee; Cho, Seong Wook

    2017-01-01

    In this paper, we generated finite element (FE) models to predict the contact pressure between a foam mattress and the human body in a supine position. Twenty-year-old males were used for three-dimensional scanning to produce the FE human models, which was composed of skin and muscle tissue. A linear elastic isotropic material model was used for the skin, and the Mooney-Rivlin model was used for the muscle tissue because it can effectively represent the nonlinear behavior of muscle. The contact pressure between the human model and the mattress was predicted by numerical simulation. The human models were validated by comparing the body pressure distribution obtained from the same human subject when he was lying on two different mattress types. The experimental results showed that the slope of the lower part of the mattress caused a decrease in the contact pressure at the heels, and the effect of bone structure was most pronounced in the scapula. After inserting a simple structure to function as the scapula, the contact pressure predicted by the FE human models was consistent with the experimental body pressure distribution for all body parts. These results suggest that the models proposed in this paper will be useful to researchers and designers of products related to the prevention of pressure ulcers.

  11. Retrospective, nonrandomized controlled study on autoadjusting, dual-pressure positive airway pressure therapy for a consecutive series of complex insomnia disorder patients

    Directory of Open Access Journals (Sweden)

    Krakow B

    2017-03-01

    Full Text Available Barry Krakow,1–3 Natalia D McIver,1,2 Victor A Ulibarri,1,2 Michael R Nadorff4,5 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Ltd, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, 4Department of Psychology, Mississippi State University, Mississippi, MS, 5Department of Psychiatry and Behavioral Sciences, Baylor College of Medicine, Houston, TX, USA Purpose: Emerging evidence shows that positive airway pressure (PAP treatment of obstructive sleep apnea (OSA and upper airway resistance syndrome (UARS in chronic insomnia patients (proposed “complex insomnia” disorder leads to substantial decreases in insomnia severity. Although continuous PAP (CPAP is the pressure mode most widely researched, intolerance to fixed pressurized air is rarely investigated or described in comorbidity patients. This retrospective study examined dual pressure, autoadjusting PAP modes in chronic, complex insomnia disorder patients.Patients and methods: Chronic insomnia disorder patients (mean [SD] insomnia severity index [ISI] =19.11 [3.34] objectively diagnosed with OSA or UARS and using either autobilevel PAP device or adaptive servoventilation (ASV device after failing CPAP therapy (frequently due to intolerance to pressurized air, poor outcomes, or emergence of CSA were divided into PAP users (≥20 h/wk and partial users (<20 h/wk for comparison. Subjective and objective baseline and follow-up measures were analyzed.Results: Of the 302 complex insomnia patients, PAP users (n=246 averaged 6.10 (1.78 nightly hours and 42.71 (12.48 weekly hours and partial users (n=56 averaged 1.67 (0.76 nightly hours and 11.70 (5.31 weekly hours. For mean (SD decreases in total ISI scores, a significant (group × time interaction was observed (F[1,300]=13.566; P<0.0001 with PAP users (–7.59 [5.92]; d=1.63 showing superior results to partial users (-4.34 [6.13]; d=0.81. Anecdotally, patients reported better tolerability with advanced PAP

  12. Cardiac effects of positive pressure ventilation in ARDS assessed by NT-proBNP, Troponin T and Troponin I

    Directory of Open Access Journals (Sweden)

    Yasser Sadek Nassar

    2013-01-01

    Although the increase in cardiac markers are insignificant, yet they point to the potentially harmful role played by high PEEP, low PH and low PaO2/FiO2 ratio on the heart. Currently, no clinically relevant conclusion can be drawn apart from the recommendation to attempt to lower PEEP and shorten the duration of positive pressure ventilation, even in patients with structurally normal hearts.

  13. Effects of sevoflurane on ventilator induced lung injury in a healthy lung experimental model.

    Science.gov (United States)

    Romero, A; Moreno, A; García, J; Sánchez, C; Santos, M; García, J

    2016-01-01

    Ventilator-induced lung injury (VILI) causes a systemic inflammatory response in tissues, with an increase in IL-1, IL-6 and TNF-α in blood and tissues. Cytoprotective effects of sevoflurane in different experimental models are well known, and this protective effect can also be observed in VILI. The objective of this study was to assess the effects of sevoflurane in VILI. A prospective, randomized, controlled study was designed. Twenty female rats were studied. The animals were mechanically ventilated, without sevoflurane in the control group and sevoflurane 3% in the treated group (SEV group). VILI was induced applying a maximal inspiratory pressure of 35 cmH2O for 20 min without any positive end-expiratory pressure for 20 min (INJURY time). The animals were then ventilated 30 min with a maximal inspiratory pressure of 12 cmH2O and 3 cmH2O positive end-expiratory pressure (time 30 min POST-INJURY), at which time the animals were euthanized and pathological and biomarkers studies were performed. Heart rate, invasive blood pressure, pH, PaO2, and PaCO2 were recorded. The lung wet-to-dry weight ratio was used as an index of lung edema. No differences were found in the blood gas analysis parameters or heart rate between the 2 groups. Blood pressure was statistically higher in the control group, but still within the normal clinical range. The percentage of pulmonary edema and concentrations of TNF-α and IL-6 in lung tissue in the SEV group were lower than in the control group. Sevoflurane attenuates VILI in a previous healthy lung in an experimental subclinical model in rats. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Mandibular Advancing Positive Pressure Apnea Remediation Device (MAPPARD)

    Science.gov (United States)

    2014-06-01

    also medical prosthesis design as well. ArtiSynth is currently working on a study, described in Chapter V, to predict whether a patient with OSA is...deformable mesh, and is measured by the fluid-solid interface. This is due to the fact that the mesh faces feel the pressure predicted from the fluid

  15. The effect of entrainment site and inspiratory pressure on the delivery of oxygen therapy during non-invasive mechanical ventilation (NIMV in acute COPD patients

    Directory of Open Access Journals (Sweden)

    Sundeep Kaul

    2006-12-01

    Full Text Available Supplemental O2 is frequently added to bi-level non-invasive ventilation circuits to maintain Sa,O2 >90%. Oxygen can be added at several points & in the presence of different inspiratory pressures. The effect of varying entrainment sites and inspiratory pressures (IPAP on PO2, PCO2, Fio2, inspiratory triggering and expiratory triggering in COPD patients is unknown. 18 patients with stable COPD (mean FEV1 47% participated in the study. Oxygen was added at 4 sites in the ventilatory circuit (site 1: between mask and exhalation port; site 2: just distal to exhalation port; site 3: at ventilator outlet; site 4: directly into the mask via an inlet. The effect of varying entrainment sites and inspiratory pressures on arterial PO2, PCO2, FIO2, was recorded at 3 mins. The same full face mask (Respironics, Image 3 & ventilator (Respironics, BIPAP ST 30 was used.

  16. A study of the pressure profiles near the first pumping aperture in a high pressure photoelectron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kahk, J. Matthias; Villar-Garcia, Ignacio J. [Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom); Grechy, Lorenza; Bruce, Paul J.K.; Vincent, Peter E. [Department of Aeronautics, Imperial College London, London SW7 2AZ (United Kingdom); Eriksson, Susanna K. [Department of Chemistry-Ångström, Uppsala University, Box 523, 751 20 Uppsala (Sweden); Rensmo, Håkan; Hahlin, Maria [Department of Physics and Astronomy, Uppsala University, Box 516, 751 20 Uppsala (Sweden); Åhlund, John; Edwards, Mårten O.M. [VG Scienta AB, Box 15120, 750 15 Uppsala (Sweden); Payne, David J., E-mail: d.payne@imperial.ac.uk [Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom)

    2015-11-15

    Highlights: • We have examined pressure variations in a high pressure photoelectron spectrometer. • Pressure profiles have been simulated using computational fluid dynamics modelling. • The results are useful for determining the optimal sample position for measurements. - Abstract: In a high-pressure photoelectron spectrometer, the sample is positioned close to a differential pumping aperture, behind which the pressure is several orders of magnitude lower than the pressure in the analysis chamber. To find the optimal sample position, where the path length of the photoelectrons through the high pressure region is minimized as far as possible without compromising knowledge of the actual pressure at the sample surface, an understanding of the pressure variations near the sample and the aperture is required. A computational fluid dynamics study has been carried out to examine the pressure profiles, and the results are compared against experimental spectra whose intensities are analyzed using the Beer–Lambert law. The resultant pressure profiles are broadly similar to the one previously derived from a simplistic molecular flow model, but indicate that as the pressure in the analysis chamber is raised, the region over which the pressure drop occurs becomes progressively narrower.

  17. A study of the pressure profiles near the first pumping aperture in a high pressure photoelectron spectrometer

    International Nuclear Information System (INIS)

    Kahk, J. Matthias; Villar-Garcia, Ignacio J.; Grechy, Lorenza; Bruce, Paul J.K.; Vincent, Peter E.; Eriksson, Susanna K.; Rensmo, Håkan; Hahlin, Maria; Åhlund, John; Edwards, Mårten O.M.; Payne, David J.

    2015-01-01

    Highlights: • We have examined pressure variations in a high pressure photoelectron spectrometer. • Pressure profiles have been simulated using computational fluid dynamics modelling. • The results are useful for determining the optimal sample position for measurements. - Abstract: In a high-pressure photoelectron spectrometer, the sample is positioned close to a differential pumping aperture, behind which the pressure is several orders of magnitude lower than the pressure in the analysis chamber. To find the optimal sample position, where the path length of the photoelectrons through the high pressure region is minimized as far as possible without compromising knowledge of the actual pressure at the sample surface, an understanding of the pressure variations near the sample and the aperture is required. A computational fluid dynamics study has been carried out to examine the pressure profiles, and the results are compared against experimental spectra whose intensities are analyzed using the Beer–Lambert law. The resultant pressure profiles are broadly similar to the one previously derived from a simplistic molecular flow model, but indicate that as the pressure in the analysis chamber is raised, the region over which the pressure drop occurs becomes progressively narrower.

  18. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.

    Science.gov (United States)

    Ng, Justin R; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G; Chai-Coetzer, Ching Li; McEvoy, R Doug; Antic, Nick

    2016-09-15

    The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  19. [Pulmonary function of children with acute leukemia in maintenance phase of chemotherapy].

    Science.gov (United States)

    de Macêdo, Thalita Medeiros Fernandes; Campos, Tania Fernandes; Mendes, Raquel Emanuele de França; França, Danielle Corrêa; Chaves, Gabriela Suéllen da Silva; de Mendonça, Karla Morganna Pereira Pinto

    2014-12-01

    The aim of this study was to assess the pulmonary function of children with acute leukemia. Cross-sectional observational analytical study that enrolled 34 children divided into groups A (17 with acute leukemia in the maintenance phase of chemotherapy) and B (17 healthy children). The groups were matched for sex, age and height. Spirometry was measured using a spirometer Microloop Viasys(®) in accordance with American Thoracic Society and European Respiratory Society guidelines. Maximal respiratory pressures were measured with an MVD300 digital manometer (Globalmed(®)). Maximal inspiratory pressures and maximal expiratory pressures were measured from residual volume and total lung capacity, respectively. Group A showed a significant decrease in maximal inspiratory pressures when compared to group B. No significant difference was found between the spirometric values of the two groups, nor was there any difference between maximal inspiratory pressure and maximal expiratory pressure values in group A compared to the lower limit values proposed as reference. Children with acute leukemia, myeloid or lymphoid, during the maintenance phase of chemotherapy exhibited unchanged spirometric variables and maximal expiratory pressure; However, there was a decrease in inspiratory muscle strength. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Prevention of pectus excavatum for children with spinal muscular atrophy type 1.

    Science.gov (United States)

    Bach, John R; Bianchi, Carlo

    2003-10-01

    To demonstrate the elimination of pectus excavatum and promotion of more normal lung growth and chest wall development by the use of high-span positive inspiratory pressure plus positive end-expiratory pressure (PIP+PEEP), patients with spinal muscular atrophy type 1 with paradoxical breathing were placed on high-span PIP+PEEP when sleeping from the point of diagnosis of spinal muscular atrophy. Although the appearance of pectus excavatum is ubiquitous in untreated infants with spinal muscular atrophy type 1, after institution of high-span PIP+PEEP, pectus resolves and lungs and chest walls grow more normally. High-span PIP+PEEP is indicated for all infants diagnosed with spinal muscular atrophy who demonstrate paradoxical breathing for the purpose of promoting more normal lung and chest development.