WorldWideScience

Sample records for positive discharge column

  1. Positive column of the discharge in a cylindrical shell

    International Nuclear Information System (INIS)

    Uehara, M.; Maciel, H.S.

    1991-01-01

    A Schottky type theoretical model is presented for the positive column of a discharge on a cylindric shell contained gas, with the discharge current flowing in the longitudinal direction. Some analytical results and the conclusion are presented. (L.C.J.A.). 5 refs

  2. Numerical study on xenon positive column discharges of mercury-free lamp

    International Nuclear Information System (INIS)

    Ouyang, Jiting; He, Feng; Miao, Jinsong; Wang, Jianqi; Hu, Wenbo

    2007-01-01

    In this paper, the numerical study has been performed on the xenon positive column discharges of mercury-free fluorescent lamp. The plasma discharge characteristics are analyzed by numerical simulation based on two-dimensional fluid model. The effects of cell geometry, such as the dielectric layer, the electrode width, the electrode gap, and the cell height, and the filling gas including the pressure and the xenon percentage are investigated in terms of discharge current and discharge efficiency. The results show that a long transient positive column will form in the xenon lamp when applying ac sinusoidal power and the lamp can operate in a large range of voltage and frequency. The front dielectric layer of the cell plays an important role in the xenon lamp while the back layer has little effect. The ratio of electrode gap to cell height should be large to achieve a long positive column xenon lamp and higher efficiency. Increase of pressure or xenon concentration results in an increase of discharge efficiency and voltage. The discussions will be helpful for the design of commercial xenon lamp cells

  3. Properties of the positive column of a glow discharge in flowing hydrogen

    International Nuclear Information System (INIS)

    Brunet, H.; Rocca Serra, J.; Mabru, M.

    1981-01-01

    Results of a theoretical model for predicting the effects of gas flow on the properties of the positive column in a glow discharge are presented. A cylindrical discharge at low pressure ( 2 molecules and H atoms produced by the discharge are calculated. Comparison with available experimental data is made

  4. Study of glow discharge positive column with cloud of disperse particles

    International Nuclear Information System (INIS)

    Polyakov, D.N.; Shumova, V.V.; Vasilyak, L.M.; Fortov, V.E.

    2011-01-01

    The study aims to describe plasma parameters changes induced by clouds of disperse micron size particles. Dust clouds were formed in the positive column of glow discharge in air at pressure 0.1-0.6 torr and current 0.1-3 mA. The simultaneous registration of discharge voltage and dust cloud parameters was carried out. Experimental results were simulated using diffusion model. The dust cloud is shown to smooth the radial electron concentration profile, increase electric field strength and electron temperature and stabilize the discharge. The cloud is demonstrated to be a trap for positive ions without increase of discharge current. -- Highlights: → 25% increase of longitudinal electric field strength in discharge with dust cloud. → The smoothing effect of dust cloud on radial electron and ion concentration profiles. → Dust cloud as a trap for positive ions without increase of discharge current. → Increase of electron temperature in discharge with dust cloud. → Increase of discharge stability in presence of dust cloud.

  5. Particle densities in a positive column He-I+ discharge

    International Nuclear Information System (INIS)

    Gato, T.

    1980-01-01

    In a positive column He-1 + laser discharge, the He + ion density has been determined directly from the absorption of the HeII 30.3 nm resonance line measured by a modified absorption method, and the electron density has been obtained using this measured He + ion density. The population densities of the upper and lower states of the 612.7 nm laser line have also been measured roughly. (orig.)

  6. Distortion of plasma due to installation of an orifice in helium discharge positive column

    International Nuclear Information System (INIS)

    Moslehi- Fard, M.; Bidadi, H.; Khorram, S.; Sobhanian, S.; Muradov, A.H.; Jallali, H.; Shirin Pour, M.

    2003-01-01

    Complicated potential structure formed at a constriction of positive column of a DC discharge with heated cathode in He at low discharge currents is investigated. According to the potential structure, electrons and ions are accelerated by the electric field and their energy distribution functions acquire multi humped shapes. Additional maximums on distribution function quickly disappear due to collisions and radial losses. The nature of current passing through the potential structure is cleared up on the base of measured distributions. Attempt was made to calculate potential drop in DL tacking into account electron energy distribution variations

  7. Study of efficacy in a mercury-free flat discharge fluorescent lamp using a zero-dimensional positive column model

    CERN Document Server

    Shiga, T; Boeuf, J P; Mikoshiba, S

    2003-01-01

    A zero-dimensional model of the positive column in Ar/Ne/Xe gas mixtures has been developed to help understand the measured dependence of the efficacy on operating conditions in a mercury-free flat fluorescent lamp in a dielectric barrier geometry. The experimental conditions are such that the radiation from the discharge is homogeneous over most of the discharge voltage. The model uses as input the discharge current waveform from the experiments, and it yields the time variations of the mean electron energy and the species densities. From these quantities we calculate the number of vacuum ultraviolet (VUV) photons emitted by the xenon resonance atoms and excimers during one current pulse and the efficiency for generation of VUV radiation in the positive column, which are compared with the measured luminance and efficacy for various voltages, pulse intervals, and lamp sizes. Over the range of conditions studied, we find that most electrical energy dissipated in xenon excitation is converted to VUV radiation; ...

  8. Elongated dust clouds in a uniform DC positive column of low pressure gas discharge

    International Nuclear Information System (INIS)

    Usachev, A D; Zobnin, A V; Petrov, O F; Fortov, V E; Thoma, M H; Pustylnik, M Y; Fink, M A; Morfill, G E

    2016-01-01

    Experimental investigations of the formation of elongated dust clouds and their influence on the plasma glow intensity of the uniform direct current (DC) positive column (PC) have been performed under microgravity conditions. For the axial stabilization of the dust cloud position a polarity switching DC gas discharge with a switching frequency of 250 Hz was used. During the experiment, a spontaneous division of one elongated dust cloud into two smaller steady state dust clouds has been observed. Quantitative data on the dust cloud shape, size and dust number density distribution were obtained. Axial and radial distributions of plasma emission within the 585.2 nm and 703.2 nm neon spectral lines were measured over the whole discharge volume. It has been found that both spectral line intensities at the dust cloud region grew 1.7 times with respect to the undisturbed positive column region; in this the 585.2 nm line intensity increased by 10% compared to the 703.2 nm line intensity. For a semi-quantitative explanation of the observed phenomena the Schottky approach based on the equation of diffusion was used. The model reasonably explains the observed glow enhancement as an increasing of the ionization rate in the discharge with dust cloud, which compensates ion-electron recombination on the dust grain surfaces. In this, the ionization rate increases due to the growing of the DC axial electric field, and the glow grows directly proportional to the electric field. It is shown that the fundamental condition of the radial stability of the dusty plasma cloud is equal to the ionization and recombination rates within the cloud volume that is possible only when the electron density is constant and the radial electric field is absent within the dust cloud. (paper)

  9. Spectral radiance of strong lines in positive column mercury discharges with argon carrier gas

    International Nuclear Information System (INIS)

    Sansonetti, Craig J; Reader, Joseph

    2006-01-01

    The spectral radiance of the 185 and 254 nm lines in two positive column mercury discharge lamps was measured over a wide range of operating conditions. The lamps had internal diameters of 5 and 23 mm. Argon was used as a carrier gas. The lamps were operated with cold spot temperatures of 20, 40 and 60 0 C. At each of these temperatures, results were obtained for five currents ranging from 20 to 100 mA for the 5 mm lamp and from 200 to 1000 mA for the 23 mm lamp. For each current studied, results were determined for argon pressures ranging from 66.6 to 666 Pa (0.5 to 5.0 Torr) in the 5 mm lamp and 26.6 to 666 Pa (0.2 to 5.0 Torr) in the 23 mm lamp. An argon miniarc was used as the radiometric standard. By calibrating the spectral response of the optical system with a well-characterized mercury pencil lamp, results were obtained for 12 additional Hg lines from 289 to 579 nm. For the 23 mm lamp the electric field in the positive column was measured. For this lamp the radiated power as a percentage of input power was also determined. The results provide an experimental basis for validating computer models of Hg fluorescent lamp discharges

  10. Positive column of a glow discharge in neon with charged dust grains (a review)

    Energy Technology Data Exchange (ETDEWEB)

    Polyakov, D. N., E-mail: cryolab@ihed.ras.ru; Shumova, V. V.; Vasilyak, L. M. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2017-03-15

    The effect of charged micron-size dust grains (microparticles) on the electric parameters of the positive column of a low-pressure dc glow discharge in neon has been studied experimentally and numerically. Numerical analysis is carried out in the diffusion-drift approximation with allowance for the interaction of dust grains with metastable neon atoms. In a discharge with a dust grain cloud, the longitudinal electric field increases. As the number density of dust grains in an axisymmetric cylindrical dust cloud rises, the growth of the electric field saturates. It is shown that the contribution of metastable atoms to ionization is higher in a discharge with dust grains, in spite of the quenching of metastable atoms on dust grains. The processes of charging of dust grains and the dust cloud are considered. As the number density of dust grains rises, their charge decreases, while the space charge of the dust cloud increases. The results obtained can be used in plasma technologies involving microparticles.

  11. Positive column of a glow discharge in neon with charged dust grains (a review)

    International Nuclear Information System (INIS)

    Polyakov, D. N.; Shumova, V. V.; Vasilyak, L. M.

    2017-01-01

    The effect of charged micron-size dust grains (microparticles) on the electric parameters of the positive column of a low-pressure dc glow discharge in neon has been studied experimentally and numerically. Numerical analysis is carried out in the diffusion-drift approximation with allowance for the interaction of dust grains with metastable neon atoms. In a discharge with a dust grain cloud, the longitudinal electric field increases. As the number density of dust grains in an axisymmetric cylindrical dust cloud rises, the growth of the electric field saturates. It is shown that the contribution of metastable atoms to ionization is higher in a discharge with dust grains, in spite of the quenching of metastable atoms on dust grains. The processes of charging of dust grains and the dust cloud are considered. As the number density of dust grains rises, their charge decreases, while the space charge of the dust cloud increases. The results obtained can be used in plasma technologies involving microparticles.

  12. A Study of a Striated Positive Column after Ethanol Impurity Injection in an Air DC Glow Discharge

    Science.gov (United States)

    Berzak, Laura; Post Zwicker, Andrew

    2003-04-01

    In a glow discharge when ethanol (CH3CH2OH) was injected, a series of atypical striations formed through the positive column. When the pressure decreased as the ethanol evaporated and was evacuated by the vacuum pump, this behavior decayed away until only an anode glow or normal discharge remained. Varying interelectrode spacings and quantities of ethanol yielded similar patterns. The typical evolution as the pressure decreased consisted of a visible traveling wave traveling from the anode to the cathode followed by numerous, thin ( 1.6 mm) striations evenly spaced down the entire length of the positive column. These, shifted back toward the anode and transformed into bent striations with the tip of the 'V' pointing toward the cathode, and finally, the 'V' striations grouped into fours and took on the appearance of beats. The unusual 'V' striations may be due in part to a contraction of the column, causing the equipotential surfaces to shift from smooth convex to the observed striation shape. The conditions for this contraction effect include a nonlinearly increasing dependence of electron production rate on electron density and a bulk recombination rate higher than that at the tube walls. Visible emission spectra indicated the presence of carbon monoxide (CO), signifying that the striations are due to not only vibrational excitation of the ethanol molecule but also to decomposition and subsequent excitation of the decomposition products as well. One possible mechanism of decomposition is the formation of a radical cation from the ethanol molecule and the ensuing loss of a proton to yield formaldehyde; this then would follow an analogous decomposition to produce carbon monoxide. Thus, there may exist additional charged species which can then contribute to the unique observations. Further analysis, if possible, will include higher temporal resolution spectroscopy and a detailed model of the positive column under these specific conditions.

  13. Development of a positive column pulsed capillary discharge source for use with high resolution Fourier transform spectrometer

    International Nuclear Information System (INIS)

    Syed, W A A

    2002-01-01

    We report the designing and application of a positive column pulsed capillary discharge with the Fourier transform spectrometer (FTS). The pulsed light source has been used for the first time with the ultraviolet FTS. The experiment has been carried out with the high energy pulsed discharge with energy of 2-3 J lasting about 300 ns. A system has been developed to trigger the discharge at about 600 Hz with the pulses directly taken from the FTS sampling system. The spectrum of Ar III has been recorded in the 19 000-50 000 cm -1 region with good signal to noise ratio. The results have opened a wide range of applications in spectroscopy of multiply ionized species

  14. Nonlocal electron kinetics and spectral line emission in the positive column of an argon glow discharge

    International Nuclear Information System (INIS)

    Golubovskii, Yu; Kalanov, D; Gorchakov, S; Uhrlandt, D

    2015-01-01

    Modern non-local electron kinetics theory predicts several interesting effects connected with spectral line emission from the positive column in the range of low and medium pressures and currents. Some theoretical works describe non-monotonic behavior of the radial profiles of line emission at intermediate pressures and currents between the validity ranges of the non-local and local approximation of the electron kinetics. Despite a great number of publications, there have been no systematic measurements attempting to confirm these theoretical predictions through experiments. In this work the radial profiles of the line emission from the positive column of an argon glow discharge have been measured with high spatial resolution and new effects caused by the narrowing and broadening of the spatial emission profiles with dependence on discharge conditions have been discovered. The effect of intensity maximum shift predicted by theory using a self-consistent model was not found in the experiment. The properties of the spectral line radiation are influenced by the peculiarities of the formation of the high-energy tail of the electron energy distribution function. An interpretation of the observed effects based on the non-local character of the electron kinetics in radially inhomogeneous fields is given. The obtained experimental data are compared with the results of calculations. (paper)

  15. Approximations to the electron energy distribution and positive column models for low-pressure discharge light sources

    International Nuclear Information System (INIS)

    Lister, G G; Sheverev, V A; Uhrlandt, D

    2002-01-01

    The applicability of 'fluid' models based on analytic approximations of the electron energy distribution function (EEDF) and of kinetic models for low-pressure discharge light sources is discussed. Traditionally, 'fluid' models of fluorescent lamps assume that the EEDF is Maxwellian up to the energy of the first excited state. It is shown that such an approach is sufficiently accurate in most cases of conventional as well as of 'highly loaded' fluorescent lamps. However, this assumption is strongly violated for many rare gas glow discharges for mercury free light sources. As an example, a neon dc discharge is studied. The densities of the four lowest excited states and the electric field have been measured. The experimental results can be fairly well reproduced by a kinetic positive column model. This article was scheduled to appear in issue 14 of J. Phys. D: Appl. Phys. To access this special issue please follow this link: http://stacks.iop.org/0022-3727/35/i=14/

  16. Dynamic Contraction of the Positive Column of a Self-Sustained Glow Discharge in Molecular Gas Flow

    Science.gov (United States)

    Shneider, Mikhail

    2014-10-01

    Contraction of the gas discharge, when current contracts from a significant volume of weakly ionized plasma into a thin arc channel, was attracted attention of scientists for more than a century. Studies of the contraction (also called constriction) mechanisms, besides carrying interesting science, are of practical importance, especially when contraction should be prevented. A set of time-dependent two-dimensional equations for the non-equilibrium weakly-ionized nitrogen/ air plasma is formulated. The process is described by a set of time-dependent continuity equations for the electrons, positive and negative ions; gas and vibrational temperature; by taking into account the convective heat and plasma losses by the transverse flux. Transition from the uniform to contracted state was analyzed. It was shown that such transition experiences a hysteresis, and that the critical current of the transition increases when the pressure (gas density) drops. Possible coexistence of the contracted and uniform state of the plasma in the discharge where the current flows along the density gradient of the background gas was discussed. In this talk the problems related to the dynamic contraction of the current channel inside a quasineutral positive column of a self-sustained glow discharge in molecular gas in a rectangular duct with convection cooling will be discussed. Study presented in this talk was stimulated by the fact that there are large number of experiments on the dynamic contraction of a glow discharge in nitrogen and air flows and a many of possible applications. Similar processes play a role in the powerful gas-discharge lasers. In addition, the problem of dynamic contraction in the large volume of non-equilibrium weakly ionized plasma is closely related to the problem of streamer to leader transitions in lightning and blue jets.

  17. Electron energy distribution function in the positive column of a neon glow discharge using the black wall approximation

    International Nuclear Information System (INIS)

    Al-Hawat, Sh; Naddaf, M

    2005-01-01

    The electron energy distribution function (EEDF) was determined from the second derivative of the I-V Langmuir probe characteristics and, thereafter, theoretically calculated by solving the plasma kinetic equation, using the black wall (BW) approximation, in the positive column of a neon glow discharge. The pressure has been varied from 0.5 to 4 Torr and the current from 10 to 30 mA. The measured electron temperature, density and electric field strength were used as input data for solving the kinetic equation. Comparisons were made between the EEDFs obtained from experiment, the BW approach, the Maxwellian distribution and the Rutcher solution of the kinetic equation in the elastic energy range. The best conditions for the BW approach are found to be under the discharge conditions: current density j d = 4.45 mA cm -2 and normalized electric field strength E/p = 1.88 V cm -1 Torr -1

  18. Electron energy distribution function in the positive column of a neon glow discharge using the black wall approximation

    Science.gov (United States)

    Al-Hawat, Sh; Naddaf, M.

    2005-04-01

    The electron energy distribution function (EEDF) was determined from the second derivative of the I-V Langmuir probe characteristics and, thereafter, theoretically calculated by solving the plasma kinetic equation, using the black wall (BW) approximation, in the positive column of a neon glow discharge. The pressure has been varied from 0.5 to 4 Torr and the current from 10 to 30 mA. The measured electron temperature, density and electric field strength were used as input data for solving the kinetic equation. Comparisons were made between the EEDFs obtained from experiment, the BW approach, the Maxwellian distribution and the Rutcher solution of the kinetic equation in the elastic energy range. The best conditions for the BW approach are found to be under the discharge conditions: current density jd = 4.45 mA cm-2 and normalized electric field strength E/p = 1.88 V cm-1 Torr-1.

  19. Electron energy distribution function in the positive column of a neon glow discharge using the black wall approximation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hawat, Sh; Naddaf, M [Physics Department, Atomic Energy Commission, PO Box 6091, Damascus (Syrian Arab Republic)

    2005-04-21

    The electron energy distribution function (EEDF) was determined from the second derivative of the I-V Langmuir probe characteristics and, thereafter, theoretically calculated by solving the plasma kinetic equation, using the black wall (BW) approximation, in the positive column of a neon glow discharge. The pressure has been varied from 0.5 to 4 Torr and the current from 10 to 30 mA. The measured electron temperature, density and electric field strength were used as input data for solving the kinetic equation. Comparisons were made between the EEDFs obtained from experiment, the BW approach, the Maxwellian distribution and the Rutcher solution of the kinetic equation in the elastic energy range. The best conditions for the BW approach are found to be under the discharge conditions: current density j{sub d} = 4.45 mA cm{sup -2} and normalized electric field strength E/p = 1.88 V cm{sup -1} Torr{sup -1}.

  20. Thomson scattering in a low-pressure argon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2000-01-01

    The electron density and the electron temperature in a low-pressure argon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 5

  1. Thomson scattering in a low-pressure neon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2001-01-01

    The electron density and the electron temperature in a low-pressure neon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 10

  2. Positive-column plasma studied by fast-flow glow discharge mass spectrometry: Could it be a 'Rydberg gas?'

    International Nuclear Information System (INIS)

    Mason, Rod S.; Miller, Pat D.; Mortimer, Ifor; Mitchell, David J.; Dash, Neil A.

    2003-01-01

    Ions created from the fast-flowing positive column plasma of a glow discharge were monitored using a high voltage magnetic sector mass spectrometer. Since the field gradient and sheath potentials created by the plasma inside the source opposed cation transfer, it is inferred that the ions detected were the field-ionized Rydberg species. This is supported by the mass spectral changes which occurred when a negative bias was applied to the sampling aperture and by the contrasting behavior when attached to a quadrupole analyzer. Reaction with H 2 (titrated into the flowing plasma) quenched not only the ionization of discharge gas Rydberg atoms but also the passage of electric current through the plasma, without significant changes to the field and sheath potentials. Few 'free' ions were present and the lifetimes of the Rydberg atoms detected were much longer than seen in lower pressure experiments, indicating additional stabilization in the plasma environment. The observations support the model of the flowing plasma, given previously [R. S. Mason, P. D. Miller, and I. P. Mortimer, Phys. Rev. E 55, 7462 (1997)] as mainly a neutral Rydberg atom gas, rather than a conventional ion-electron plasma

  3. Safety operation of chromatography column system with discharging hydrogen radiolytically generated

    International Nuclear Information System (INIS)

    Watanabe, S; Sano, Y.; Nomura, K.; Koma, Y.; Okamoto, Y.

    2015-01-01

    The extraction chromatography technology is one of the promising methods for the partitioning of minor actinides (Am and Cm) from spent nuclear fuels. In the extraction chromatography system, the accumulation of hydrogen gas in the chromatography column is suspected to lead to fire or explosion. In order to prevent hazardous accidents, it is necessary to evaluate behaviors of gas radiolytically generated inside the column. In this study, behaviors of gas inside the extraction chromatography column were investigated through experiments and Computation Fluid Dynamics (CFD) simulation. N_2 gas once accumulated as bubbles in the packed bed was hardly discharged by the flow of mobile phase. However, the CFD simulation and X-ray imaging on γ-ray irradiated column revealed that during operation the hydrogen gas generated in the column was dissolved into the mobile phase without accumulation and then discharged. (authors)

  4. Two-dimensional positive column structure with dust cloud: Experiment and nonlocal kinetic simulation

    Science.gov (United States)

    Zobnin, A. V.; Usachev, A. D.; Petrov, O. F.; Fortov, V. E.; Thoma, M. H.; Fink, M. A.

    2018-03-01

    The influence of a dust cloud on the structure of the positive column of a direct current gas discharge in a cylindrical glass tube under milligravity conditions has been studied both experimentally and numerically. The discharge was produced in neon at 60 Pa in a glass tube with a diameter of 30 mm at a discharge current 1 mA. Spherical monodisperse melamine formaldehyde dust particles with a diameter of 6.86 μm were injected into the positive column and formed there a uniform dust cloud with a maximum diameter of 14.4 mm. The shape of the cloud and the dust particle number density were measured. The cloud was stationary in the radial direction and slowly drifted in the axial direction. It was found that in the presence of the dust cloud, the intensity of the neon spectral line with a wavelength by 585.25 nm emitted by the discharge plasma increased by 2.3 times and 2 striations appeared on the anode side of the cloud. A numerical simulation of the discharge was performed using the 2D (quasi-3D) nonlocal self-consistent kinetic model of a longitudinally inhomogeneous axially symmetric positive column [Zobnin et al., Phys. Plasmas 21, 113503 (2014)], which was supplemented by a program module performing a self-consistent calculation of dust particle charges, the plasma recombination rate on dust particles, and ion scattering on dust particles. A new approach to the calculation of particle charges and the screening radius in dense dust clouds is proposed. The results of the simulation are presented, compared with experimental data and discussed. It is demonstrated that for the best agreement between simulated and experimental data, it is necessary to take into account the reflection of electrons from the dust particle surface in order to correctly describe the recombination rate in the cloud, its radial stability, and the dust particle charges.

  5. Kinetic theory of the positive column of a low-pressure discharge in a transverse magnetic field

    International Nuclear Information System (INIS)

    Londer, Ya. I.; Ul’yanov, K. N.

    2011-01-01

    The influence of a transverse magnetic field on the characteristics of the positive column of a planar low-pressure discharge is studied theoretically. The motion of magnetized electrons is described in the framework of a continuous-medium model, while the ion motion in the ambipolar electric field is described by means of a kinetic equation. Using mathematical transformations, the problem is reduced to a secondorder ordinary differential equation, from which the spatial distribution of the potential is found in an analytic form. The spatial distributions of the plasma density, mean plasma velocity, and electric potential are calculated, the ion velocity distribution function at the plasma boundary is found, and the electron energy as a function of the magnetic field is determined. It is shown that, as the magnetic field rises, the electron energy increases, the distributions of the plasma density and mean plasma velocity become asymmetric, the maximum of the plasma density is displaced in the direction of the Ampère force, and the ion flux in this direction becomes substantially larger than the counter-directed ion flux.

  6. Influence of second kind collisions on the electron distribution function in the positive column of low pressure nitrogen discharge

    International Nuclear Information System (INIS)

    Rohlena, K.; Ruzicka, T.

    1979-01-01

    A numerical solution of the Boltzmann equation for the electron gas in the positive column of a DC discharge in nitrogen is presented. The Boltzmann equation was solved with the inclusion of the second-kind (superelastic) collisions proceeding from the first six excited vibrational levels of molecular nitrogen. The vibrational level population is supposed to follow the Boltzmann distribution for the given vibrational temperature Tsub(v), with a possible deviation of the ground level, which can be overpopulated in the given ratio γ. Apart from the electron distribution functions, which were gained for various values of E/p 0 , Tsub(v) and γ, the values of some production frequencies and kinetic coefficients are presented in form of tables and plots. It is found that the electron distribution (and also the corresponding production rates) only above a certain energy limit depends on Tsub(v) and γ through the normalization constant. (author)

  7. Modulation of ionization in the plasma column of an optical discharge

    International Nuclear Information System (INIS)

    Nastoyashchii, A.F.

    1981-01-01

    Stability of the ionization in the plasma column of an optical discharge is discussed. It is shown that a plasma filament formed by a long laser spike under optical discharge conditions may break up into a chain of bright luminous layers oriented in the direction of propagation of a laser beam and characterized by a higher gas ionization (''optical striations''). A nonlinear formulation of the problem is used to find the depth of modulation of the gas ionization

  8. Pilot scale ion exchange column study for reducing radioactivity discharges to environment

    International Nuclear Information System (INIS)

    Kore, S.G.; Yadav, V.K.; Sonar, N.L.; Valsala, T.P.; Narayan, J.; Sharma, S.P.; Chattopadhyay, S.; Dani, U.; Vishwaraj, I.

    2013-01-01

    Low level liquid waste (LLW) is generated during operation of Tarapur Atomic Power Station (TAPS). Chemical co-precipitation is the treatment method used for decontamination of this waste with respect to radionuclide prior to discharge to environment. Further polishing of effluent from the treated LLW was planned using ion exchange column to reduce the discharges to the environment In view of this ion exchange column study was carried out in the laboratory using in-house prepared cobalt ferrocyanide (COFC) based composite resin. Based on the encouraging results obtained in the lab studies, pilot scale study was carried out in the plant. Decontamination factor (DF) of 14-15 was obtained with respect to Cs isotopes and overall DF of 2-5 was obtained with respect to gross beta activity. (author)

  9. Electric discharge during electrosurgery.

    Science.gov (United States)

    Shashurin, Alexey; Scott, David; Zhuang, Taisen; Canady, Jerome; Beilis, Isak I; Keidar, Michael

    2015-04-16

    Electric discharge utilized for electrosurgery is studied by means of a recently developed method for the diagnostics of small-size atmospheric plasma objects based on Rayleigh scattering of microwaves on the plasma volume. Evolution of the plasma parameters in the near-electrode sheaths and in the positive column is measured and analyzed. It is found that the electrosurgical system produces a glow discharge of alternating current with strongly contracted positive column with current densities reaching 10(3) A/cm(2). The plasma electron density and electrical conductivities in the channel were found be 10(16) cm(-3) and (1-2) Ohm(-1) cm(-1), respectively. The discharge interrupts every instance when the discharge-driving AC voltage crosses zero and re-ignites again every next half-wave at the moment when the instant voltage exceeds the breakdown threshold.

  10. Plasma pressure in the discharge column of the Novillo Tokamak

    International Nuclear Information System (INIS)

    Gaytan G, E.

    1995-01-01

    The design and construction of an acquisition system for the measurement of the plasma pressure in the Novillo Tokamak is described in detail. The system includes a high voltage ramp generator, a hardware and a software interface with a personal computer. It is used to determine experimentally the variations of the pressure in the plasma column in the cleaning and main discharges. The measurement of the pressure is made with a Pirani sensor adapted to the acquisition hardware and synchronized with the discharge in the plasma. The software is made in object oriented programming as a graphic interface designed to be used easily. It controls the acquisition, records the data, displays in graphic form the results and save the measurements. The graphic interface is a building block that can be used in different acquisition tasks. The ramp generator can deliver a signal of 200 V peak to peak with a current of 200 m A and offset control. The acquisition time is 2.5 μ s for every measurement, 8192 measurements can be stored in the acquisition board for every discharge. (Author)

  11. Space structure of the glow discharge with free side boundary

    International Nuclear Information System (INIS)

    Yatsenko, N.A.

    1995-01-01

    The main purpose of this work is to reveal physical reasons, which are responsible for the formation of space structure of glow type discharge with free side boundary, both in DC and in RF electric fields. By now extensive experimental material have been accumulated in discharge physics. Also many theoretical models have been proposed for describing separate parts of discharge with the cold electrodes (cathode and anode regions, positive column and transition zones - glow luminescence and Farraday's dark space of DC-discharge, electrode regions and plasma column of RF capacitive discharge). As this takes place, the majority of known works are devoted to some one part of gas discharge - positive column, electrode regions, transition zones and so on. At the same time just now we don't know anything about space structure of free, steady-state gas discharge of glow type, as a whole, especially when the pressure p much-gt 1 Torr

  12. Influence of dust particles on the neon spectral line intensities at the uniform positive column of dc discharge at the space apparatus “Plasma Kristall-4”

    Science.gov (United States)

    Usachev, A. D.; Zobnin, A. V.; Shonenkov, A. V.; Lipaev, A. M.; Molotkov, V. I.; Petrov, O. F.; Fortov, V. E.; Pustyl'nik, M. Y.; Fink, M. A.; Thoma, M. A.; Thomas, H. M.; Padalka, G. I.

    2018-01-01

    Influence of the elongated dust cloud on the intensities of different neon spectral lines in visible and near ir spectral ranges in the uniform positive column has been experimentally investigated using the Russian-European space apparatus “Plasma Kristall-4” (SA PK-4) on board of the International Space Station (ISS). The investigation was performed in the low pressure (0.5 mbar) direct current (dc, 1 mA) gas discharge in neon. Microgravity allowed us to perform experiments with a large dust cloud in the steady-state regime. To avoid the dust cloud drift in the dc electric field a switching dc polarity discharge mode has been applied. During the experiment a dust cloud of 9 mm in diameter in the discharge tube of 30 mm in diameter with the length of about 100 mm has been observed in the steady-state regime. In this regard, the intensities of neon spectral lines corresponding to 3p → 3s electronic transitions have increased by a factor of 1.4 times, while the intensities of neon spectral lines corresponding to 3d → 3p electronic transitions have increased by a factor of 1.6 times. The observed phenomenon is explained on the basis of the Schottky approach by a self-consistent rising dc electric field in the dusty plasma cloud resulting in an increase of the electron temperature.

  13. Development of a numerical model for calculating exposure to toxic and nontoxic stressors in the water column and sediment from drilling discharges.

    Science.gov (United States)

    Rye, Henrik; Reed, Mark; Frost, Tone Karin; Smit, Mathijs G D; Durgut, Ismail; Johansen, Øistein; Ditlevsen, May Kristin

    2008-04-01

    Drilling discharges are complex mixtures of chemical components and particles which might lead to toxic and nontoxic stress in the environment. In order to be able to evaluate the potential environmental consequences of such discharges in the water column and in sediments, a numerical model was developed. The model includes water column stratification, ocean currents and turbulence, natural burial, bioturbation, and biodegradation of organic matter in the sediment. Accounting for these processes, the fate of the discharge is modeled for the water column, including near-field mixing and plume motion, far-field mixing, and transport. The fate of the discharge is also modeled for the sediment, including sea floor deposition, and mixing due to bioturbation. Formulas are provided for the calculation of suspended matter and chemical concentrations in the water column, and burial, change in grain size, oxygen depletion, and chemical concentrations in the sediment. The model is fully 3-dimensional and time dependent. It uses a Lagrangian approach for the water column based on moving particles that represent the properties of the release and an Eulerian approach for the sediment based on calculation of the properties of matter in a grid. The model will be used to calculate the environmental risk, both in the water column and in sediments, from drilling discharges. It can serve as a tool to define risk mitigating measures, and as such it provides guidance towards the "zero harm" goal.

  14. Propagation of ionizing waves in glow discharge

    International Nuclear Information System (INIS)

    Suzuki, T.

    1977-01-01

    Ionizing waves were produced along the positive column of a glow discharge in air by applying an impulse voltage to an electrode at one end of the column. Five photomultipliers and three current-sensing coils were used to observe how the waves were affected by the rise time and the magnitude of the applied impulses and by the electron density in the positive column of the glow discharge. It is shown that the speed of the ionizing waves increases with the slope of the applied impulses and with the preexisting electron density. The electron density is augmented about 100--200 times due to the buildup of ionization at the front of the waves. The theory was developed to explain the property of ionizing waves

  15. Characteristics of the self-excited ionization waves in a magnetized positive column

    International Nuclear Information System (INIS)

    Maruyama, Takeo; Yamamura, Yasuhiro; Takano, Saburo; Miura, Kosuke; Imazu, Shingo.

    1979-01-01

    In the past, metastable atoms were not considered in the investigations of ionization waves generated in a positive column weakly ionized. However, metastable atoms seem to be important for the generation of ionization waves, and there are many unknown factors. In this paper, the fundamental equations and dispersion relation are explained under the assumption of axi-symmetrical positive column plasma placed in a uniform magnetic field, and the direct ionization frequency and excitation frequency, cumulative ionization coefficient, electron density and metastable atom density, the energy loss factor for electrons, the dependence of plasma quantities on magnetic field and dispersion characteristics are calculated. Experiments have been conducted using Ne gas in a discharge tube of 80 cm long and 1 cm radius with heated oxide cathode. Magnetic field was obtained with a solenoid coil of 75 cm long, 9 cm I.D. and 27 cm O.D. The axially uniform magnetic field was in the range of 35 to 40 cm. As the results, the following points have become clear. (1) The number of waves, angular frequency and phase velocity of ionization waves decrease with the increase of magnetic field. (2) By the consideration of the presence of metastable atoms, the theoretical values were improved pretty well and agreed with the experimental values qualitatively and quantitatively. (3) Longitudinal magnetic field has the effect of suppressing the growth of ionization waves because of the reduction of time and spatial growth rates with the increase of magnetic field. (Wakatsuki, Y.)

  16. Simulation of nonstationary phenomena in atmospheric-pressure glow discharge

    Science.gov (United States)

    Korolev, Yu. D.; Frants, O. B.; Nekhoroshev, V. O.; Suslov, A. I.; Kas'yanov, V. S.; Shemyakin, I. A.; Bolotov, A. V.

    2016-06-01

    Nonstationary processes in atmospheric-pressure glow discharge manifest themselves in spontaneous transitions from the normal glow discharge into a spark. In the experiments, both so-called completed transitions in which a highly conductive constricted channel arises and incomplete transitions accompanied by the formation of a diffuse channel are observed. A model of the positive column of a discharge in air is elaborated that allows one to interpret specific features of the discharge both in the stationary stage and during its transition into a spark and makes it possible to calculate the characteristic oscillatory current waveforms for completed transitions into a spark and aperiodic ones for incomplete transitions. The calculated parameters of the positive column in the glow discharge mode agree well with experiment. Data on the densities of the most abundant species generated in the discharge (such as atomic oxygen, metastable nitrogen molecules, ozone, nitrogen oxides, and negative oxygen ions) are presented.

  17. Simulation of nonstationary phenomena in atmospheric-pressure glow discharge

    International Nuclear Information System (INIS)

    Korolev, Yu. D.; Frants, O. B.; Nekhoroshev, V. O.; Suslov, A. I.; Kas’yanov, V. S.; Shemyakin, I. A.; Bolotov, A. V.

    2016-01-01

    Nonstationary processes in atmospheric-pressure glow discharge manifest themselves in spontaneous transitions from the normal glow discharge into a spark. In the experiments, both so-called completed transitions in which a highly conductive constricted channel arises and incomplete transitions accompanied by the formation of a diffuse channel are observed. A model of the positive column of a discharge in air is elaborated that allows one to interpret specific features of the discharge both in the stationary stage and during its transition into a spark and makes it possible to calculate the characteristic oscillatory current waveforms for completed transitions into a spark and aperiodic ones for incomplete transitions. The calculated parameters of the positive column in the glow discharge mode agree well with experiment. Data on the densities of the most abundant species generated in the discharge (such as atomic oxygen, metastable nitrogen molecules, ozone, nitrogen oxides, and negative oxygen ions) are presented.

  18. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2015-01-01

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing......, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius...

  19. Theory of a wall sheath in a gas-discharge plasma

    International Nuclear Information System (INIS)

    Dvinin, S.A.; Dovzhenko, V.A.; Kuzovnikov, A.A.

    1999-01-01

    An integro-differential equation is proposed that generalizes the plasma-sheath (Langmuir-Tonks) equation to include charge exchange between ions and neutrals in a discharge plasma and makes it possible to correctly analyze how the discharge evolves from the regime of collisionless ion motion to the diffusive regime in pure gases with allowance for the space charge in the sheath at the plasma boundary. The integro-differential equation is solved numerically, and the ionization rate is calculated as a function of the ratio between the ion mean free path and the characteristic discharge dimension. The ion energy distribution function in the positive column of a discharge plasma is computed. The parameter range in which the positive column can exist is examined, and the limits of applicability of different discharge models are analyzed depending on the relations between the ion mean free path, Debye length, and discharge dimension

  20. Measurement of electric field distribution along the plasma column in Microwave jet discharges at atmospheric pressure

    International Nuclear Information System (INIS)

    Razzak, M. Abdur; Takamura, Shuichi; Tsujikawa, Takayuki; Shibata, Hideto; Hatakeyama, Yuto

    2009-01-01

    A new technique for the direct measurement of electric field distribution along the plasma column in microwave jet discharges is developed and employed. The technique is based on a servomotor-controlled reciprocating antenna moving along the nozzle axis and plasma column. The measurement technique is applied to a rectangular waveguide-based 2.45 GHz argon and helium plasma jets generated by using the modified TIAGO nozzle at atmospheric pressure with a microwave power of less than 500 W. The measurement has been done with and without igniting the plasma jet in order to investigate the standing wave propagation along the nozzle axis and plasma column. It is observed that the electric field decay occurs slowly in space with plasma ignition than that of without plasma, which indicates the surface electromagnetic wave propagation along the plasma column in order to sustain the plasma jet. This study enables one to design, determine and optimize the size and structure of launcher nozzle, which plays an important role for the stable and efficient microwave plasma generators. (author)

  1. Development of a numerical model for calculating exposure to toxic and nontoxic stressors in the water column and sediment from drilling discharges

    NARCIS (Netherlands)

    Rye, H.; Reed, M.; Frost, T.K.; Smit, M.G.D.; Durgut, S.

    2008-01-01

    Drilling discharges are complex mixtures of chemical components and particles which might lead to toxic and nontoxic stress in the environment. In order to be able to evaluate the potential environmental consequences of such discharges in the water column and in sediments, a numerical model was

  2. Effect of a sound wave on the stability of an argon discharge

    International Nuclear Information System (INIS)

    Galechyan, G.A.; Karapetyan, D.M.; Tavakalyan, L.B.

    1992-01-01

    The effect of a sound wave on the stability of the positive column of an argon discharge has been studied experimentally in the range of pressures from 40 to 180 torr and discharge currents from 40 to 110 mA in a tube with an interior diameter of 9.8 cm. It is shown that, depending on the intensity of the sound wave and the discharge parameters, sound can cause the positive column either to contract or to leave the contracted state. The electric field strength has been measured as a function of the sound intensity. An analogy between the effect of sound and that of longitudinal pumping of the gas on the argon discharge parameters has been established. The radial temperature of the gas has been studied in an argon discharge as a function of the sound intensity for different gas pressures. A direct relationship has been established between the sign of the detector effect produced by a sound wave in a discharge and the processes of contraction and filamentation of a discharge. 11 refs., 4 figs., 1 tab

  3. Effect of mobilities and electric field on the stability of magnetized positive column

    International Nuclear Information System (INIS)

    Dogra, V.K.; Uberoi, M.S.

    1983-01-01

    The effect of ratio of the mobilities of electrons and ions and non-dimensional electric field, on the stability of magnetized positive column for all unstable modes is studied in a self-consistent formulation for the perturbations of plasma density and electric potential. The minimum non-dimensional electric field at which magnetized positive column becomes unstable for different ratios of the mobilities of electrons and ions is also investigated. (author)

  4. HPLC separation of triacylglycerol positional isomers on a polymeric ODS column.

    Science.gov (United States)

    Kuroda, Ikuma; Nagai, Toshiharu; Mizobe, Hoyo; Yoshimura, Nobuhito; Gotoh, Naohiro; Wada, Shun

    2008-07-01

    A polymeric ODS column was applied to the resolution of triacylglycerol positional isomers (TAG-PI), i.e. 1,3-dioleoyl-2-palmitoyl-glycerol (OPO) and 1,2-dioleoyl-3-palmitoyl-rac-glycerol (OOP), with a recycle HPLC system. To investigate the ODS column species and the column temperatures for the resolution of a TAG-PI pair, a mixture of OPO and OOP was subjected to an HPLC system equipped with a non-endcapped polymeric, endcapped monomeric, endcapped intermediate, or non-endcapped monomeric ODS column at three different column temperatures (40, 25, or 10 degrees C). Only the non-endcapped polymeric ODS column achieved the separation of OPO and OOP, and the lowest column temperature (10 degrees C) showed the best resolution for them. The other pair of TAG-PI, a mixture of 1,3-dipalmitoyl-2-oleoyl-glycerol (POP) and 1,2-dipalmitoyl-3-oleoyl-rac-glycerol (PPO) was also subjected to the system equipped with a non-endcapped polymeric or monomeric ODS column at five different column temperatures (40, 32, 25, 17, and 10 degrees C). Thus, POP and PPO were also separated on only the non-endcapped polymeric ODS column at 25 degrees C. However, no clear peak appeared at 10 degrees C. These results would indicate that the polymeric ODS stationary phase has an ability to recognize the structural differences between TAG-PI pairs. Also, the column temperature is a very important factor for separating the TAG-PI pair, and the optimal temperature would relate to the solubility of TAG-PI in the mobile phase. Furthermore, the recycle HPLC system provided measurements for the separation and analysis of TAG-PI pairs.

  5. Formation of electrostatic double-layers and electron-holes in a low pressure mercury plasma column

    International Nuclear Information System (INIS)

    Petraconi, G; Maciel, Homero S

    2003-01-01

    Experimental studies of the formation of electrostatic double layers (DLs) and electron-holes (e-holes) are reported. The measurements were performed in the positive column of a mercury arc discharge operating in the low-pressure range of (2.0-14.0) x 10 -2 Pa with current density in the range of (3.0-8.0) x 10 3 A m -2 . Stable and unstable modes of the discharge were identified as the current was gradually increased, keeping constant the vapour pressure. The discharge remains stable until a critical current from which a slight increase of the current leads to an unstable regime characterized by high discharge impedance and strong oscillations. This mode ceased after a DL was formed in the plasma column. To induce the DL formation and to transport it smoothly along the discharge column, a low intensity B-field (7-10) x 10 -3 T produced by a movable single coil was used. The B-field locally increases the electron current density and makes the DL form at the centre of the magnetic constriction where it remained at rest. Electrostatic potential structures compatible with ordinary DLs and multiple-layers could be formed in the plasma column by dealing with the combined effects of the operational parameters of the discharge. It is noticeable that a pure e-hole, which is a symmetric triple-layer having a bell shape potential profile, could easily be formed by means of this experimental technique. A partial kinetic description, based on the space charge structure derived from an experimental e-hole, is presented in order to infer the charged particle populations that could contribute to the space charge of the e-hole. Evidence is shown that strong e-hole formation might be driven by an ion beam, therefore it could not be formed in isolation since its formation requires a nearby ion accelerating potential structure. Probe measurements of the plasma properties, at various radial positions of the stable positive column, are also presented. In the stable mode, prior to

  6. Excitation of RF oscillations in a discharge with negative differential conductivity

    International Nuclear Information System (INIS)

    Antonov, A.N.; Kovpik, O.F.; Kornilov, E.A.

    2001-01-01

    The excitation of oscillations in a discharge with negative differential conductivity is studied experimentally. The possibility is demonstrated of amplifying oscillations in the cathode dark space at frequencies close to the electron plasma frequency of the positive-column plasma. The phase velocities of waves at these frequencies are determined. When the waves pass from the cathode dark space to the discharge positive column, their phase velocities decrease; the closer the frequency is to the electron plasma frequency, the more pronounced the decrease in the phase velocity. As the intensity of oscillations increases, the discharge becomes non-steady-state. This is confirmed by the time evolution of the current-voltage characteristic. The shape of the current-voltage characteristic, its splitting, and the rate at which it varies depend on the input RF power. The decrease in the cathode dark space indicates that the ionization processes in the discharge are strongly influenced by electron plasma oscillations excited due to the collective interaction of the electron beam formed at the cathode with the discharge plasma. It is these processes that determine the maximum values of both the frequency of the excited oscillations and the power that can be withdrawn from the discharge

  7. Plasma-column instabilities in a reversed-field pinch without a shell

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, P.G.

    1988-01-01

    Plasma column instabilities in a Reversed Field Pinch (RFP) without a shell were investigated in the Colorado Reversatron RFP. The Reversatron RFP (aspect ration R/a = 50 cm/8cm) is a toroidal plasma containment device consisting of a vacuum chamber, a thick conducting shell, modular shells, magnetic field producing coils and diagnostics to characterize the plasma. RFP discharges were set up in the Reversatron in three different experimental configurations: with a thick conducting shell, with a modular shell and with no shell. In two of the configurations, a shell enclosed the plasma column to provide some plasma stability. A vertical magnetic field provided equilibrium in experiments without a shell. Data from discharges without a shell indicated that the plasma duration was greatly reduced and the plasma resistance increased compared to the discharges with a thick shell. Plasma position probes indicated large plasma centriod displacements corresponding to a n = 1 and a n = 3 kink coincident with the peak of the plasma current and the start of a discharge termination phase. The modular shell lengthened the discharge duration and lowered the plasma resistance to values intermediate between the plasma with a thick shell and the plasma with no shell. The modular shell suppressed the large plasma column displacements observed in the RFP plasma without a shell.

  8. Plasma-column instabilities in a reversed-field pinch without a shell

    International Nuclear Information System (INIS)

    Schmid, P.G.

    1988-01-01

    Plasma column instabilities in a Reversed Field Pinch (RFP) without a shell were investigated in the Colorado Reversatron RFP. The Reversatron RFP (aspect ration R/a = 50 cm/8cm) is a toroidal plasma containment device consisting of a vacuum chamber, a thick conducting shell, modular shells, magnetic field producing coils and diagnostics to characterize the plasma. RFP discharges were set up in the Reversatron in three different experimental configurations: with a thick conducting shell, with a modular shell and with no shell. In two of the configurations, a shell enclosed the plasma column to provide some plasma stability. A vertical magnetic field provided equilibrium in experiments without a shell. Data from discharges without a shell indicated that the plasma duration was greatly reduced and the plasma resistance increased compared to the discharges with a thick shell. Plasma position probes indicated large plasma centriod displacements corresponding to a n = 1 and a n = 3 kink coincident with the peak of the plasma current and the start of a discharge termination phase. The modular shell lengthened the discharge duration and lowered the plasma resistance to values intermediate between the plasma with a thick shell and the plasma with no shell. The modular shell suppressed the large plasma column displacements observed in the RFP plasma without a shell

  9. A pulser-sustainer carbon monoxide electric-discharge supersonic laser

    Science.gov (United States)

    Monson, D. J.; Srinivasan, G.

    1977-01-01

    Operation of a CW CO electric-discharge supersonic laser with a pulser-sustainer discharge is described. High-power operation as well as independent control over electron energy and density are demonstrated. Maximum input power achieved to date is 100 kW. The maximum output power is 6 kW or 10% of the sustainer positive-column power. Much improved performance appears possible.

  10. Low pressure arc discharge lamp apparatus with magnetic field generating means

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Maya, Jakob

    1987-01-01

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25.degree. C.

  11. Low pressure arc discharge lamp apparatus with magnetic field generating means

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1987-10-06

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

  12. Is the negative glow plasma of a direct current glow discharge negatively charged?

    International Nuclear Information System (INIS)

    Bogdanov, E. A.; Saifutdinov, A. I.; Demidov, V. I.; Kudryavtsev, A. A.

    2015-01-01

    A classic problem in gas discharge physics is discussed: what is the sign of charge density in the negative glow region of a glow discharge? It is shown that traditional interpretations in text-books on gas discharge physics that states a negative charge of the negative glow plasma are based on analogies with a simple one-dimensional model of discharge. Because the real glow discharges with a positive column are always two-dimensional, the transversal (radial) term in divergence with the electric field can provide a non-monotonic axial profile of charge density in the plasma, while maintaining a positive sign. The numerical calculation of glow discharge is presented, showing a positive space charge in the negative glow under conditions, where a one-dimensional model of the discharge would predict a negative space charge

  13. Closed form analytic solutions describing glow discharge plasma

    International Nuclear Information System (INIS)

    Pai, S.T.; Guo, X.M.; Zhou, T.D.

    1996-01-01

    On the basis of an analytic model developed previously [S. T. Pai, J. Appl. Phys. 71, 5820 (1992)], an improved version of the model for the description of dc glow discharge plasma was successfully developed. A set of closed form solutions was obtained from the governing equations. The two-dimensional, analytic solutions are functional and completely satisfy the governing equations, the actual boundary conditions, and Maxwell equations. They can be readily used to carry out numerical calculations without the necessity of employing any assumed boundary conditions. Results obtained from the model reveal that as the discharge gap spacing or pressure increases the maximum value in the electron density distribution moves toward the cathode. At a sufficiently large value of gap spacing, the positive column phenomenon begins to appear in the discharge region. The model has the capability of treating the positive column and negative glow as a continuous system without the necessity of studying them separately. The model also predicts a sharp rise of the positive ion density near the cathode and field reversal in the anode region. Variation of the electrode radius produces little effect on the axial spatial distribution of physical quantities studied. copyright 1996 American Institute of Physics

  14. Impedance-stabilized positive corona discharge and its decontamination properties

    Energy Technology Data Exchange (ETDEWEB)

    Horak, P; Khun, J, E-mail: pavel.horak@vscht.c [Department of Physics and Measurements, Faculty of Chemical Engineering, Institute of Chemical Technology, Technicka 5, 166 28 Praha 6 (Czech Republic)

    2010-04-01

    The point-to-plane DC corona discharge in air at atmospheric pressure was stabilized by a serially connected ballast impedance. The ballast impedance was implemented by a resistor-capacitor group connected in parallel. In the case of connecting the serial impedance into the electric circuit of a negative corona, the transition into a spark takes place at parameters similar to those of a non-stabilized discharge. In contrast, in the case of a positive corona, the discharge does not undergo a transition into a spark, but rather into a mode of periodic streamers. We measured the bactericidal effect of the stabilized discharge. The experiments showed that after a 2-minute exposure the quantity of surviving bacteria decreased from 95% for a non-stabilized discharge down to 5% for a stabilized one.

  15. Impedance-stabilized positive corona discharge and its decontamination properties

    International Nuclear Information System (INIS)

    Horak, P; Khun, J

    2010-01-01

    The point-to-plane DC corona discharge in air at atmospheric pressure was stabilized by a serially connected ballast impedance. The ballast impedance was implemented by a resistor-capacitor group connected in parallel. In the case of connecting the serial impedance into the electric circuit of a negative corona, the transition into a spark takes place at parameters similar to those of a non-stabilized discharge. In contrast, in the case of a positive corona, the discharge does not undergo a transition into a spark, but rather into a mode of periodic streamers. We measured the bactericidal effect of the stabilized discharge. The experiments showed that after a 2-minute exposure the quantity of surviving bacteria decreased from 95% for a non-stabilized discharge down to 5% for a stabilized one.

  16. Determination of the plasma impedance of a glow discharge in carbon dioxide

    Science.gov (United States)

    Kiselev, A. S.; Smirnov, E. A.

    2017-07-01

    In this work an expression for the dynamic resistance of a glow discharge flowing in long tubes is obtained and analyzed. The expression describes the physical processes occurring in the positive column of a glow discharge. The frequency dependences of the active and reactive components as well as the dynamic resistance module for the discharge conditions corresponding to CO2-lasers have been calculated. Based on the simulation results developed a computer program in the C# programming language for modeling the dynamic resistance discharge of glow discharge lasers.

  17. Study of the metastable singlet of molecular nitrogen and of oxygen atoms in discharges and post-discharges

    International Nuclear Information System (INIS)

    Magne, Lionel

    1991-01-01

    Whereas discharges in nitrogen, in oxygen and in their mixtures are used in many different industrial processes (surface treatment, nitridation, oxidation, and so on), in order to get a better knowledge on nitrogen electronic states, this research thesis reports the study of the metastable singlet state of molecular nitrogen, and of oxygen atoms in their fundamental state. The molecular metastable has been observed by far-UV optical emission spectroscopy, in the positive column of a continuous discharge and in time post-discharge. As far as continuous discharge is concerned, the author measured the vibrational distribution of this state. A kinetic model has been developed, and calculated vibrational distributions are in good agreement with measurements. The density of oxygen atoms in fundamental state in time post-discharge has been measured by far-UV absorption optical spectroscopy. The probability of atom re-association of glass walls is deduced from the obtained results [fr

  18. Branching of positive discharge streamers in air at varying pressures

    NARCIS (Netherlands)

    Briels, T.M.P.; Veldhuizen, van E.M.; Ebert, U.M.

    2005-01-01

    The formation of positive streamers in a 17-mm gap in air is studied at pressures varying in the range from 1010 to 100 mbar. An intensified charge coupled device camera is used to image the discharge. At high pressures, the discharge shows many branches, while at low pressure, fewer branches arise.

  19. Stationary striations due to interaction of two ionization waves in xenon glow discharge

    International Nuclear Information System (INIS)

    Maruyama, T.; Nishina, S.; Kitamura, H.; Itagaki, K.; Mizuochi, H.

    1990-01-01

    Experimental observations on stationary striations in the positive column of xenon discharge are reported. Stationary striations are observed when two ionization waves exist simultaneously in the positive column at low pressure and high current region. These stationary striations are caused by nonlinear interference of two backward ionization waves of which frequencies are either equal or are in the ratio 1:2. The spatial intervals for the striated pattern are equal to the reciprocal of the difference between the wave-numbers of two ionization waves. (orig.)

  20. Glow discharge in singlet oxygen

    International Nuclear Information System (INIS)

    Vagin, N.P.; Ionin, A.A.; Klimachev, Yu.M.; Sinitsyn, D.V.; Yuryshev, N.N.; Kochetov, I.V.; Napartovich, A.P.

    2003-01-01

    Currently, there is no experimental data on the plasma balance in gas mixtures with a high content of singlet delta oxygen O 2 ( 1 Δ g ). These data can be obtained by studying the parameters of an electric discharge in singlet oxygen produced by a chemical generator. The O 2 ( 1 Δ g ) molecules significantly change the kinetics of electrons and negative ions in plasma. Hence, the discharge conditions at low and high O 2 ( 1 Δ g ) concentrations are very different. Here, the parameters of the positive column of a glow discharge in a gas flow from a chemical singlet-oxygen generator are studied. It is experimentally shown that, at an O 2 ( 1 Δ g ) concentration of 50% and at pressures of 1.5 and 2 torr, the electric field required to sustain the discharge is considerably lower than in the case when all of the oxygen molecules are in the ground state. A theoretical model of the glow discharge is proposed whose predictions are in good agreement with the experimental data

  1. Fast imaging of intermittent electrospraying of water with positive corona discharge

    International Nuclear Information System (INIS)

    Pongrác, B; Janda, M; Martišovitš, V; Machala, Z; Kim, H H

    2014-01-01

    The effect of the electrospraying of water in combination with a positive direct current (dc) streamer corona discharge generated in air was investigated in this paper. We employed high-speed camera visualizations and oscilloscopic discharge current measurements in combination with an intensified charge-coupled device camera for fast time-resolved imaging. The repetitive process of Taylor cone formation and droplet formation from the mass fragments of water during the electrospray was visualized. Depending on the applied voltage, the following intermittent modes of electrospraying typical for water were observed: dripping mode, spindle mode, and oscillating-spindle mode. The observed electrospraying modes were repetitive with a frequency of a few hundreds of Hz, as measured from the fast image sequences. This frequency agreed well with the frequency of the measured streamer current pulses. The presence of filamentary streamer discharges at relatively low voltages probably prevented the establishment of a continuous electrospray in the cone–jet mode. After each streamer, a positive glow corona discharge was established on the water filament tip, and it propagated from the stressed electrode along with the water filament elongation. The results show a reciprocal character of intermittent electrospraying of water, and the presence of corona discharge, where both the electrospray and the discharge affect each other. The generation of a corona discharge from the water cone depended on the repetitive process of the cone formation. Also, the propagation and curvature of the water filament were influenced by the discharge and its resultant space charge. Furthermore, these phenomena were partially influenced by the water conductivity. (paper)

  2. Magnetic-field control of low-pressure diffuse discharges

    International Nuclear Information System (INIS)

    Cooper, J.R.

    1986-01-01

    Application of a magnetic field in a direction transverse to the electric field in a diffuse discharge can have a strong effect on the transport parameters in the discharge medium and on the external characteristics of the discharge as a whole. Deviations in these transport parameters were investigated in this work by means of Monte Carlo calculations, and the electrical characteristics of the total discharge were observed experimentally. Results of the theoretical investigation show that, in attaching gas mixtures, both the ionization and attachment-rate coefficients in the positive column of the discharge are changed such that the combined effect results in an increase in resistivity. Experimentally, it is seen that application of a crossed magnetic field to an abnormal glow discharge in attaching gases in a certain parameter range causes the discharge voltage to increase significantly. The effect seems to be most strongly influenced by processes in the cathode-fall region

  3. Simulating the inception of pulsed discharges near positive electrodes

    Science.gov (United States)

    Teunissen, Jannis; Ebert, Ute

    2013-09-01

    With 3D particle simulations we study the inception of pulsed discharges near positive electrodes. In different geometries, we first determine the breakdown voltage. Then we study the probability of inception for a fast voltage pulse. This probability mostly depends on the availability of seed electrons to generate the initial electron avalanches. These results are compared with experimental observations. Then we investigate how the shape of a starting discharge affects its further development. In particular, we discuss the formation of so-called ``inception clouds.'' JT was supported by STW-project 10755.

  4. Bacterial vaginosis (clue cell-positive discharge) : diagnostic, ultra-structural and therapeutic aspects

    NARCIS (Netherlands)

    W.I. van der Meijden (Willem)

    1987-01-01

    textabstractThis thesis deals with several aspects of (abnormal) vaginal discharge, focusing especially on clue cell-positive discharge (bacterial vaginosis, nonspecific vaginitis). It reports data on epidemiology and clinical features, pathogenesis, and treatment of this vaginal disease entity,

  5. Gas Temperature Measurement in a Glow Discharge Plasma

    Science.gov (United States)

    Sloneker, Kenneth; Podder, Nirmol; McCurdy, William E.; Shi, Shi

    2009-10-01

    In this study a relatively inexpensive quartz protected thermocouple is used to measure the gas temperature in the positive column of a glow discharge plasma. For simplicity a K-type thermocouple is used to interpret the gas temperature from the sensor voltage at pressures from 0.5 Torr to 15 Torr and discharge currents from 5 mA to 120 mA. Gas temperature is investigated as a function of the gas pressure at fixed discharge currents and as a function of discharge current at fixed gas pressures in three different gas species (Ar, N2, and He). An infinite cylinder model is used to compute the average gas temperature of the discharge from joule heating and gas thermal conductivity. The model and measurement data agree within 1% to 10% depending on plasma parameters. Data for all three gases have a similar quasi-linear increasing error as compared to the model.

  6. Comment on “Two-dimensional positive column structure in a discharge tube with radius discontinuity” [Phys. Plasmas 21, 113503 (2014)

    Energy Technology Data Exchange (ETDEWEB)

    Demidova, M. V. [Department of Chemistry, Wright State University, Dayton, Ohio 45435 (United States); Division of NLP Technology, INTEPH Technology LLC, Dayton, Ohio 45066 (United States); Kudryavtsev, A. A. [Division of NLP Technology, INTEPH Technology LLC, Dayton, Ohio 45066 (United States); International Laboratory “Nonlocal Plasma in Nanotechnology and Medicine”, ITMO University, Kronverkskiy pr. 49, St. Petersburg 197101 (Russian Federation); Kurlyandskaya, I. P. [International Laboratory “Nonlocal Plasma in Nanotechnology and Medicine”, ITMO University, Kronverkskiy pr. 49, St. Petersburg 197101 (Russian Federation); Department of Optics, St. Petersburg State University, St. Petersburg 199034 (Russian Federation); Saifutdinov, A. I.; Stepanova, O. M. [Department of Optics, St. Petersburg State University, St. Petersburg 199034 (Russian Federation)

    2015-09-15

    Zobnin et al. have published a paper [Phys. Plasmas, 21, 113503 (2014)] on a topic of discharge physics in the presence of a sharp change in cylindrical discharge geometry. In the comment it is pointed out that for untrapped electrons a full kinetic equation, which includes dependences on spatial coordinates and energies, has to be used for the electron velocity distribution function determination. It is also unclear what probe theories Zobnin et al. have used in their paper for the calculation of electron current to the discharge tube wall.

  7. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  8. Small Winter Thunderstorm with Sprites and Strong Positive Discharge

    Science.gov (United States)

    Suzuki, Tomoyuki; Hayakawa, Masashi; Michimoto, Koichiro

    A sprite campaign was conducted in the Hokuriku area of Japan during a winter of 2004/2005. On the basis of a combined analysis of the data from various instruments (CCD cameras, radar, VHF/LF∼MF lightning mapping system, field mill network, and ELF detector), we studied meteorological and electrical structures for winter thunderstorms and sprite-producing positive discharge. Typical winter sprite parent thunderstorms had a meso-scale cloud area with embedded small convective cells. Some small winter thunderstorms accompanied by the most frequent sprite events were found to cause 2∼3 sprite events during a short interval of about 3∼5 min. When the sprites were observed, the extent of the convective cells at 20 dBZ counter was atmost ∼20 × 20 km. The VHF sources associated with sprites were located near south of the convective cell and were mapped within very small areas of at most ∼10 × 10 km. This fact shows that some small winter thunderstorms can generate large positive charge associated with sprites. We will present the analysis of such a small thunderstorms with sprites and positive lightning discharges.

  9. Ozone production process in pulsed positive dielectric barrier discharge

    Science.gov (United States)

    Ono, Ryo; Oda, Tetsuji

    2007-01-01

    The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O2 + M → O3 + M, is estimated to be 2.5 × 10-34 cm6 s-1.

  10. Ozone production process in pulsed positive dielectric barrier discharge

    International Nuclear Information System (INIS)

    Ono, Ryo; Oda, Tetsuji

    2007-01-01

    The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O 2 + M → O 3 + M, is estimated to be 2.5 x 10 -34 cm 6 s -1

  11. An investigation of transient pressure and plasma properties in a pinched plasma column. M.S. Thesis

    Science.gov (United States)

    Stover, E. K.; York, T. M.

    1971-01-01

    The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with the following plasma diagnostics: a special rapid response pressure transducer, a magnetic field probe, a voltage probe and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior; they were in temporal sequence: strong axial pressure asymmetry noted early in plasma column lifetime followed by plasma heating in which there is a rapid rise in static pressure and a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating is attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity. Turbulent heating arising from discharge current excitation of the ion acoustic wave instability is also considered a possible heating mechanism.

  12. Dynamic characteristics of positive hollow needle to plate atmospheric pressure discharge

    Czech Academy of Sciences Publication Activity Database

    Khun, J.; Šimek, Milan; Pekárek, S.; Schmidt, Jiří

    2006-01-01

    Roč. 56, suppl.B (2006), s. 830-836 ISSN 0011-4626. [Symposium on Plasma Physics and Technology/22nd./. Praha, 26.6.2006-29.6.2006] R&D Projects: GA AV ČR(CZ) IAA1043403 Institutional research plan: CEZ:AV0Z20430508 Keywords : positive corona discharge * streamer * mean repetition frequency * mean propagation velocity Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.568, year: 2006

  13. Ozone production process in pulsed positive dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Ryo [High Temperature Plasma Center, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba, 227-8568 (Japan); Oda, Tetsuji [Department of Electrical Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 (Japan)

    2007-01-07

    The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O{sub 2} + M {yields} O{sub 3} + M, is estimated to be 2.5 x 10{sup -34} cm{sup 6} s{sup -1}.

  14. Propagation and diffusion of a plasma column in a magnetic field

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Gadda, E.; Prevot, F.

    1966-12-01

    A plasma column is created in a magnetic field by longitudinal diffusion from a low-pressure pulsed discharge in hydrogen. Depending on the discharge conditions, two regimes are obtained in which the gas pumping speed has a different effect upon the plasma density in the column. Calculations are presented which can explain this effect by a difference in the transverse diffusion coefficient. (authors) [fr

  15. Rotation of a magnesium plasma column in a background gas

    International Nuclear Information System (INIS)

    Bosco, E. Del; Dallaqua, R.S.

    1993-01-01

    Measurements of the angular velocity of a plasma column in a surrounding gas atmosphere are presented. The plasma is produced by a pulsed, high current arc discharge in the presence of an axial magnetic field. The angular velocity is measured using the cross correlation technique applied to the floating potential signals measured by two Langmuir probes. The main result is that when gas is added to the discharge the angular velocity is always lower than the case when there is no gas, this effect been more pronounced in the beginning of the discharge. For pressures higher than ∼ 2 x 10 -2 Pa there is a effect of the gas on the plasma column rotation and the angular velocity diminishes even at the end of discharge. (author)

  16. Columnar discharge mode between parallel dielectric barrier electrodes in atmospheric pressure helium

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Yanpeng; Zheng, Bin; Liu, Yaoge [School of Electric Power, South China University of Technology, Guangzhou 510640 (China)

    2014-01-15

    Using a fast-gated intensified charge-coupled device, end- and side-view photographs were taken of columnar discharge between parallel dielectric barrier electrodes in atmospheric pressure helium. Based on three-dimensional images generated from end-view photographs, the number of discharge columns increased, whereas the diameter of each column decreased as the applied voltage was increased. Side-view photographs indicate that columnar discharges exhibited a mode transition ranging from Townsend to glow discharges generated by the same discharge physics as atmospheric pressure glow discharge.

  17. Efficiency of ozone production by pulsed positive corona discharge in synthetic air

    Energy Technology Data Exchange (ETDEWEB)

    Simek, Milan [Institute of Plasma Physics, Department of Pulsed Plasma Systems, Academy of Sciences of the Czech Republic, Prague (Czech Republic)]. E-mail: simek@ipp.cas.cz; Clupek, Martin [Institute of Plasma Physics, Department of Pulsed Plasma Systems, Academy of Sciences of the Czech Republic, Prague (Czech Republic)

    2002-06-07

    We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short ({approx}150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10{sup -4}-3x10{sup -1} Wh l{sup -1}) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min{sup -1}). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh{sup -1} and 35-110 eV/molecule. (author)

  18. Self-consistent model for pulsed direct-current N2 glow discharge

    International Nuclear Information System (INIS)

    Liu Chengsen

    2005-01-01

    A self-consistent analysis of a pulsed direct-current (DC) N 2 glow discharge is presented. The model is based on a numerical solution of the continuity equations for electron and ions coupled with Poisson's equation. The spatial-temporal variations of ionic and electronic densities and electric field are obtained. The electric field structure exhibits all the characteristic regions of a typical glow discharge (the cathode fall, the negative glow, and the positive column). Current-voltage characteristics of the discharge can be obtained from the model. The calculated current-voltage results using a constant secondary electron emission coefficient for the gas pressure 133.32 Pa are in reasonable agreement with experiment. (authors)

  19. Electron Density in Atmospheric Pressure Microwave Surface Wave Discharges

    International Nuclear Information System (INIS)

    Jasinski, M.; Zakrzewski, Z.; Mizeraczyk, J.

    2008-01-01

    In this paper, we present results of the spectroscopic measurements of the electron density in a microwave surface wave sustained discharges in Ar and Ne at atmospheric pressure. The discharge in the form of a plasma column was generated inside a quartz tube cooled with a dielectric liquid. The microwave power delivered to the discharge via rectangular waveguide was applied in the range of 200-1500 W. In all investigations presented in this paper, the gas flow rate was relatively low (0.5 l/min), so the plasma column was generated in the form of a single filament, and the lengths of the upstream and downstream plasma columns were almost the same. The electron density in the plasma columns was determined using the method based on the Stark broadening of H β spectral line, including plasma region inside the waveguide which was not investigated earlier

  20. Expansion of a nitrogen discharge by sound

    International Nuclear Information System (INIS)

    Antinyan, M.A.; Galechyan, G.A.; Tavakalyan, L.B.

    1992-01-01

    When the background pressure and the discharge current in a gas discharge are raised the plasma column is tightened up into a filament. Then the discharge occupies a region of the discharge tube whose transverse dimensions are substantially less than those of the tube. This contraction phenomenon in discharges restricts the range of parameters used in various devices to the range of relatively low discharge currents and low gas pressures. This contraction interferes with creating high-power gas lasers, since it acts destructively on the lasing process. In order to suppress filamentation of discharges the working gas has been pumped through the system at high speed, with considerable success. The turbulent mixing in the stream plays an important role in creating an uncontracted discharge at high pressures. The purpose of the present work is to study the possibility of undoing the contraction of a nitrogen discharge, which is one of the main components in the operation of a CO 2 laser, by introducing an intense sound wave in the discharge tube. Discharge contraction and the effect of a sound wave propagating along the plasma column have been investigated experimentally in nitrogen by studying the current-voltage characteristics of a contracted discharge. 6 refs., 3 figs

  1. An investigation of transient pressures and plasma properties in a pinched plasma column. M.S. Thesis

    Science.gov (United States)

    Stover, E. K.; York, T. M.

    1971-01-01

    The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with several plasma diagnostics; they were: a rapid response pressure transducer, a magnetic field probe, a voltage probe, and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior: (1) strong axial pressure asymmetry noted early in plasma column lifetime, (2) followed by plasma heating in which there is a rapid rise in static pressure, and (3) a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating could be attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity.

  2. Experimental investigation and numerical modelling of positive corona discharge: ozone generation

    Energy Technology Data Exchange (ETDEWEB)

    Yanallah, K; Castellanos, A [Departamento de Electronica y Electromagnetismo, Universidad de Sevilla (Spain); Pontiga, F; Fernandez-Rueda, A [Departamento de FIsica Aplicada II, Universidad de Sevilla (Spain)

    2009-03-21

    The spatial distribution of the species generated in a wire-cylinder positive corona discharge in pure oxygen has been computed using a plasma chemistry model that includes the most significant reactions between electrons, ions, atoms and molecules. The plasma chemistry model is included in the continuity equations of each species, which are coupled with Poisson's equation for the electric field and the energy conservation equation for the gas temperature. The current-voltage characteristic measured in the experiments has been used as an input data to the numerical simulation. The numerical model is able to reproduce the basic structure of the positive corona discharge and highlights the importance of Joule heating on ozone generation. The average ozone density has been computed as a function of current intensity and compared with the experimental measurements of ozone concentration determined by UV absorption spectroscopy.

  3. Experimental investigation and numerical modelling of positive corona discharge: ozone generation

    International Nuclear Information System (INIS)

    Yanallah, K; Castellanos, A; Pontiga, F; Fernandez-Rueda, A

    2009-01-01

    The spatial distribution of the species generated in a wire-cylinder positive corona discharge in pure oxygen has been computed using a plasma chemistry model that includes the most significant reactions between electrons, ions, atoms and molecules. The plasma chemistry model is included in the continuity equations of each species, which are coupled with Poisson's equation for the electric field and the energy conservation equation for the gas temperature. The current-voltage characteristic measured in the experiments has been used as an input data to the numerical simulation. The numerical model is able to reproduce the basic structure of the positive corona discharge and highlights the importance of Joule heating on ozone generation. The average ozone density has been computed as a function of current intensity and compared with the experimental measurements of ozone concentration determined by UV absorption spectroscopy.

  4. Experimental investigation and numerical modelling of positive corona discharge: ozone generation

    Science.gov (United States)

    Yanallah, K; Pontiga, F; Fernández-Rueda, A; Castellanos, A

    2009-03-01

    The spatial distribution of the species generated in a wire-cylinder positive corona discharge in pure oxygen has been computed using a plasma chemistry model that includes the most significant reactions between electrons, ions, atoms and molecules. The plasma chemistry model is included in the continuity equations of each species, which are coupled with Poisson's equation for the electric field and the energy conservation equation for the gas temperature. The current-voltage characteristic measured in the experiments has been used as an input data to the numerical simulation. The numerical model is able to reproduce the basic structure of the positive corona discharge and highlights the importance of Joule heating on ozone generation. The average ozone density has been computed as a function of current intensity and compared with the experimental measurements of ozone concentration determined by UV absorption spectroscopy.

  5. Storage and discharge of a granular fluid.

    Science.gov (United States)

    Pacheco-Martinez, Hector; van Gerner, Henk Jan; Ruiz-Suárez, J C

    2008-02-01

    Experiments and computational simulations are carried out to study the behavior of a granular column in a silo whose walls are able to vibrate horizontally. The column is brought to a steady fluidized state and it behaves similar to a hydrostatic system. We study the dynamics of the granular discharge through openings at the bottom of the silo in order to search for a Torricelli-like behavior. We show that the flow rate scales with the wall induced shear rate, and at high rates, the granular bed indeed discharges similar to a viscous fluid.

  6. Jump in the amplitude of a sound wave associated with contraction of a nitrogen discharge

    International Nuclear Information System (INIS)

    Galechyan, G.A.; Mkrtchyan, A.R.; Tavakalyan, L.B.

    1993-01-01

    The use of a sound wave created by an external source and directed along the positive column of a nitrogen discharge in order to make the discharge pass to the contracted state is studied experimentally. A phenomenon involving a jump in the sound wave amplitude, caused by the discharge contraction, is observed and studied. It is established that the amplitude of the sound wave as a function of the discharge current near the jump exhibits hysteresis. It is shown that in the field of a high-intensity sound wave causing the discharge to expand eliminates the jump in the sound amplitude. The dependence of the growth time of the sound amplitude caused by the jump in this quantity on the sound wave intensity is determined. 24 refs., 4 figs., 1 tab

  7. Bi-iliac distance and iliac bone position compared to the vertebral column in normal fetal development

    DEFF Research Database (Denmark)

    Hartling, U B; Fischer Hansen, B; Skovgaard, L T

    2001-01-01

    Prenatal standards of bi-iliac width were not found in the literature based on autopsy investigations, nor was the caudo-cranial position of the ilia compared to the vertebral column. The first purpose of the present study was to establish normal standard values for the bi-iliac distance in fetal...... life, the second to evaluate the level of the iliac bones proportional to the ossified vertebral column. Whole body radiographs in antero-posterior projections from 98 human fetuses (36 female and 44 male fetuses, as well as 18 fetuses on which the sex had not been determined) were analyzed...... caliper. The caudo-cranial position of the iliac bones was evaluated. The present study shows that in normal fetal development there is a continuous linear enlargement of the pelvic region in the transverse and vertical planes. The upper iliac contour stays at the level of the first sacral vertebral body...

  8. Treatment of Dyeing Wastewater by Using Positive Pulsed Corona Discharge to Water Surface

    Science.gov (United States)

    Young, Sun Mok; Hyun, Tae Ahn; Joeng, Tai Kim

    2007-02-01

    This study investigated the treatment of textile-dyeing wastewater by using an electrical discharge technique (positive pulsed corona discharge). The high-voltage electrode was placed above the surface of the wastewater while the ground electrode was submerged in the wastewater. The electrical discharge starting at the tip of the high voltage electrode propagated toward the surface of the wastewater, producing various oxidative radicals and ozone. Oxygen was used as the working gas instead of air to prevent nitrogen oxides from forming. The simulated wastewater was made up with amaranth, which is a kind of azo dye. The results obtained showed that the chromaticity of the wastewater was almost completely removed within an hour. The ultraviolet/visible spectra of the wastewater treated by the electrical discharge revealed that the total hydrocarbon level also decreased significantly.

  9. Treatment of Dyeing Wastewater by Using Positive Pulsed Corona Discharge to Water Surface

    International Nuclear Information System (INIS)

    Mok, Young Sun; Ahn, Hyun Tae; Kim, Joeng Tai

    2007-01-01

    This study investigated the treatment of textile-dyeing wastewater by using an electrical discharge technique (positive pulsed corona discharge). The high-voltage electrode was placed above the surface of the wastewater while the ground electrode was submerged in the wastewater. The electrical discharge starting at the tip of the high voltage electrode propagated toward the surface of the wastewater, producing various oxidative radicals and ozone. Oxygen was used as the working gas instead of air to prevent nitrogen oxides from forming. The simulated wastewater was made up with amaranth, which is a kind of azo dye. The results obtained showed that the chromaticity of the wastewater was almost completely removed within an hour. The ultraviolet/visible spectra of the wastewater treated by the electrical discharge revealed that the total hydrocarbon level also decreased significantly

  10. Electric discharge synthesis of HCN in simulated Jovian atmospheres

    Science.gov (United States)

    Stribling, Roscoe; Miller, Stanley L.

    1987-01-01

    Corona discharge is presently considered as a possible source of the HCN detected in the Jovian atmosphere at 2.2 x 10 to the -7th moles/sq cm column density, for the cases of gas mixtures containing H2, CH4, and NH3, with H2/CH4 ratios from 4.4 to 1585. A 3:1 ratio of corona discharge to lightning energy similar to that of the earth is applied to Jupiter. Depending on the lightning energy available on Jupiter and the eddy diffusion coefficients in the synthesis region, HCN column densities generated by corona discharge could account for about 10 percent of the HCN observed.

  11. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  12. Investigations into electrical discharges in gases

    CERN Document Server

    Klyarfel'D, B N

    2013-01-01

    Investigations into Electrical Discharges in Gases is a compilation of scientific articles that covers the advances in the investigation of the fundamental processes occurring in electrical discharges in gases and vapors. The book details the different aspects of the whole life cycle of an arc, which include the initiation of a discharge, its transition into an arc, the lateral spread of the arc column, and the recovery of electric strength after extinction of an arc. The text also discusses the methods for the dynamic measurement of vapor density in the vicinity of electrical discharges, alon

  13. audio-ultrasonic waves by argon gas discharge

    International Nuclear Information System (INIS)

    Ragheb, M.S.

    2010-01-01

    in the present work, wave emission formed by audio-ultrasonic plasma is investigated. the evidence of the magnetic and electric fields presence is performed by experimental technique. comparison between experimental field measurements and several plasma wave methods reveals the plasma audio-ultrasonic radiations mode. this plasma is a symmetrically driven capacitive discharge, consisting of three interactive regions: the electrodes, the sheaths, and the positive column regions . the discharge voltage is up to 900 volts, the discharge current flowing through the plasma attains a value of 360 mA .the frequency of the discharge voltage covers the audio and the ultrasonic range up to 100 khz. the effective plasma working distance has increased to attain the total length of the tube of 40 cm. a non-disturbing method using an external coil is used to measure the electric discharge field in a plane perpendicular to that of the plasma axe tube. this method proves the existence of a current flowing in a direction perpendicular to the plasma axe tube. a system of minute coils sensors proved the existence of two fields in two perpendicular directions . comparison between different observed fields reveals the existence of propagating electromagnetic waves due to the alternating current flowing through the skin plasma tube. the field intensity distribution along the tube draws the discharge current behavior between the two plasma electrodes that can be used to predict the range of the plasma discharge current.

  14. Sheath and arc-column voltages in high-pressure arc discharges

    International Nuclear Information System (INIS)

    Benilov, M S; Benilova, L G; Li Heping; Wu Guiqing

    2012-01-01

    Electrical characteristics of a 1 cm-long free-burning atmospheric-pressure argon arc are calculated by means of a model taking into account the existence of a near-cathode space-charge sheath and the discrepancy between the electron and heavy-particle temperatures in the arc column. The computed arc voltage exhibits a variation with the arc current I similar to the one revealed by the experiment and exceeds experimental values by no more than approximately 2 V in the current range 20-175 A. The sheath contributes about two-thirds or more of the arc voltage. The LTE model predicts a different variation of the arc voltage with I and underestimates the experimental values appreciably for low currents but by no more than approximately 2 V for I ≳ 120 A. However, the latter can hardly be considered as a proof of unimportance of the space-charge sheath at high currents: the LTE model overestimates both the resistance of the bulk of the arc column and the resistance of the part of the column that is adjacent to the cathode, and this overestimation to a certain extent compensates for the neglect of the voltage drop in the sheath. Furthermore, if the latter resistance were evaluated in the framework of the LTE model in an accurate way, then the overestimation would be still much stronger and the obtained voltage would significantly exceed those observed in the experiment.

  15. Small surface wave discharge at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kiss' ovski, Zh; Kolev, M; Ivanov, A; Lishev, St; Koleva, I, E-mail: kissov@phys.uni-sofia.b [Faculty of Physics, Sofia University, BG-1164 Sofia (Bulgaria)

    2009-09-21

    A small surface wave driven source produces plasma at atmospheric pressure. Microwave power at frequency 2.45 GHz is coupled with the source and a discharge is ignited at power levels below 10 W. The coaxial exciter of the surface waves has a length of 10 mm because its dielectric is a high permittivity discharge tube. The plasma source operates as a plasma jet in the case of plasma columns longer than the tube length. The source maintains stable plasma columns over a wide range of neutral gas flow and applied power in continuous and pulse regimes. An additional advantage of this source is the discharge self-ignition. An electron temperature of T{sub e} {approx} 1.9 eV and a density of n{sub e} {approx} 3.9 x 10{sup 14} cm{sup -3} are estimated by the probe diagnostics method. The emission spectra in the wavelength range 200-1000 nm under different experimental conditions are analysed and they prove the applicability of the source for analytical spectroscopy. The dependences of column length, reflected power and plasma parameters on the gas flow and the input power are discussed. (fast track communication)

  16. A semi-analytical study of positive corona discharge in wire–plane electrode configuration

    International Nuclear Information System (INIS)

    Yanallah, K; Pontiga, F; Chen, J H

    2013-01-01

    Wire-to-plane positive corona discharge in air has been studied using an analytical model of two species (electrons and positive ions). The spatial distributions of electric field and charged species are obtained by integrating Gauss's law and the continuity equations of species along the Laplacian field lines. The experimental values of corona current intensity and applied voltage, together with Warburg's law, have been used to formulate the boundary condition for the electron density on the corona wire. To test the accuracy of the model, the approximate electric field distribution has been compared with the exact numerical solution obtained from a finite element analysis. A parametrical study of wire-to-plane corona discharge has then been undertaken using the approximate semi-analytical solutions. Thus, the spatial distributions of electric field and charged particles have been computed for different values of the gas pressure, wire radius and electrode separation. Also, the two dimensional distribution of ozone density has been obtained using a simplified plasma chemistry model. The approximate semi-analytical solutions can be evaluated in a negligible computational time, yet provide precise estimates of corona discharge variables. (paper)

  17. A semi-analytical study of positive corona discharge in wire-plane electrode configuration

    Science.gov (United States)

    Yanallah, K.; Pontiga, F.; Chen, J. H.

    2013-08-01

    Wire-to-plane positive corona discharge in air has been studied using an analytical model of two species (electrons and positive ions). The spatial distributions of electric field and charged species are obtained by integrating Gauss's law and the continuity equations of species along the Laplacian field lines. The experimental values of corona current intensity and applied voltage, together with Warburg's law, have been used to formulate the boundary condition for the electron density on the corona wire. To test the accuracy of the model, the approximate electric field distribution has been compared with the exact numerical solution obtained from a finite element analysis. A parametrical study of wire-to-plane corona discharge has then been undertaken using the approximate semi-analytical solutions. Thus, the spatial distributions of electric field and charged particles have been computed for different values of the gas pressure, wire radius and electrode separation. Also, the two dimensional distribution of ozone density has been obtained using a simplified plasma chemistry model. The approximate semi-analytical solutions can be evaluated in a negligible computational time, yet provide precise estimates of corona discharge variables.

  18. Microwave discharges in capillary tubes

    International Nuclear Information System (INIS)

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  19. Experimental study on thermal characteristics of positive leader discharges using Mach-Zehnder interferometry

    International Nuclear Information System (INIS)

    Zhou, X.; Zeng, R.; Zhuang, C.; Chen, S.

    2015-01-01

    Leader discharge is one of the main phases in long air gap breakdown, which is characterized by high temperature and high conductivity. It is of great importance to determine thermal characteristics of leader discharges. In this paper, a long-optical-path Mach-Zehnder interferometer was set up to measure the thermal parameters (thermal diameter, gas density, and gas temperature) of positive leader discharges in atmospheric air. IEC standard positive switching impulse voltages were applied to a near-one-meter point-plane air gap. Filamentary channels with high gas temperature and low density corresponding to leader discharges were observed as significant distortions in the interference fringe images. Typical diameters of the entire heated channel range from 1.5 mm to 3.5 mm with an average expansion velocity of 6.7 m/s. In contrast, typical diameters of the intensely heated region with a sharp gas density reduction range from 0.4 mm to 1.1 mm, about one third of the entire heated channel. The radial distribution of the gas density is calculated from the fringe displacements by performing an Abel inverse transform. The typical calculated gas density reduction in the center of a propagating leader channel is 80% to 90%, corresponding to a gas temperature of 1500 K to 3000 K based on the ideal gas law. Leaders tend to terminate if the central temperature is below 1500 K

  20. Experimental study on thermal characteristics of positive leader discharges using Mach-Zehnder interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, X., E-mail: zhouxuan12@mails.thu.edu.cn; Zeng, R.; Zhuang, C.; Chen, S. [Department of Electrical Engineering, Tsinghua University, Beijing 100084 (China)

    2015-06-15

    Leader discharge is one of the main phases in long air gap breakdown, which is characterized by high temperature and high conductivity. It is of great importance to determine thermal characteristics of leader discharges. In this paper, a long-optical-path Mach-Zehnder interferometer was set up to measure the thermal parameters (thermal diameter, gas density, and gas temperature) of positive leader discharges in atmospheric air. IEC standard positive switching impulse voltages were applied to a near-one-meter point-plane air gap. Filamentary channels with high gas temperature and low density corresponding to leader discharges were observed as significant distortions in the interference fringe images. Typical diameters of the entire heated channel range from 1.5 mm to 3.5 mm with an average expansion velocity of 6.7 m/s. In contrast, typical diameters of the intensely heated region with a sharp gas density reduction range from 0.4 mm to 1.1 mm, about one third of the entire heated channel. The radial distribution of the gas density is calculated from the fringe displacements by performing an Abel inverse transform. The typical calculated gas density reduction in the center of a propagating leader channel is 80% to 90%, corresponding to a gas temperature of 1500 K to 3000 K based on the ideal gas law. Leaders tend to terminate if the central temperature is below 1500 K.

  1. Experimental study of hard X-rays emitted from meter-scale positive discharges in air

    NARCIS (Netherlands)

    P.O. Kochkin (Pavlo); C.V. Nguyen; A. van Deursen (Arie); U. M. Ebert (Ute)

    2012-01-01

    textabstractWe investigate structure and evolution of long positive spark breakdown; and we study at which stage pulses of hard x-rays are emitted. Positive high-voltage pulses of standardized lightning impulse wave form of about 1 MV were applied to about 1 m of ambient air. The discharge evolution

  2. Observations of nonlinear behaviour in a low-pressure discharge column

    International Nuclear Information System (INIS)

    Cartier, S.L.; Merlino, R.L.

    1984-01-01

    Sudden and abrupt jumps in the plasma density and discharge current of low-pressure magnetized argon and helium plasmas are observed. These jumps are found to depend on the discharge bias voltage, the neutral gas pressure, and the magnetic field strength and occur with a substantial hysteresis in those parameters. These jumps are accompanied by the onset of intense and coherent low-frequency plasma oscillations. In addition, under certain conditions, the radial density profile of the plasma is found to be significantly different following a jump. Some possibly related plasma instabilities are discussed

  3. Radio frequency glow discharge source with integrated voltage and current probes used for evaluation of discharge parameters

    International Nuclear Information System (INIS)

    Wilken, L.; Hoffmann, V.; Wetzig, K.

    2006-01-01

    A radio frequency (rf) Grimm-type glow discharge source for the chemical analysis of solid samples, with integrated voltage and current probes, was developed. All elements of a plasma equivalent circuit are determined from the measured current-voltage characteristics. The procedure is based on the independent evaluation of the ion current and electron current region. The physical meaning of the parameters is investigated by comparisons with measurements from dc glow discharges. We found that the reduced rf current of the powered electrode is comparable to the reduced current in dc discharges. A formula is developed that corrects the reduced current due to gas heating. The sheath thickness at the powered rf electrode is evaluated and is between 75 and 1100 μm. The voltage of the bulk plasma is in the range 2-15 V, and the resistance is between 30 and 400 Ω. The bulk plasma consumes about 3% of the total power, and the reduced voltage is comparable to the reduced electrical field in the positive column of direct current discharges. The sheath voltage at the grounded electrode is in the range 25-100 V, the capacities are between 10 and 400 pF, and the resistances are in the range 100 Ω-5000 Ω. We also found invariants for the evaluated sheath parameters

  4. Sustained diffusive alternating current gliding arc discharge in atmospheric pressure air

    Science.gov (United States)

    Zhu, Jiajian; Gao, Jinlong; Li, Zhongshan; Ehn, Andreas; Aldén, Marcus; Larsson, Anders; Kusano, Yukihiro

    2014-12-01

    Rapid transition from glow discharge to thermal arc has been a common problem in generating stable high-power non-thermal plasmas especially at ambient conditions. A sustained diffusive gliding arc discharge was generated in a large volume in atmospheric pressure air, driven by an alternating current (AC) power source. The plasma column extended beyond the water-cooled stainless steel electrodes and was stabilized by matching the flow speed of the turbulent air jet with the rated output power. Comprehensive investigations were performed using high-speed movies measured over the plasma column, synchronized with simultaneously recorded current and voltage waveforms. Dynamic details of the novel non-equilibrium discharge are revealed, which is characterized by a sinusoidal current waveform with amplitude stabilized at around 200 mA intermediate between thermal arc and glow discharge, shedding light to the governing mechanism of the sustained spark-suppressed AC gliding arc discharge.

  5. Comparison of bottom-track to global positioning system referenced discharges measured using an acoustic Doppler current profiler

    Science.gov (United States)

    Wagner, Chad R.; Mueller, David S.

    2011-01-01

    A negative bias in discharge measurements made with an acoustic Doppler current profiler (ADCP) can be caused by the movement of sediment on or near the streambed. The integration of a global positioning system (GPS) to track the movement of the ADCP can be used to avoid the systematic negative bias associated with a moving streambed. More than 500 discharge transects from 63 discharge measurements with GPS data were collected at sites throughout the US, Canada, and New Zealand with no moving bed to compare GPS and bottom-track-referenced discharges. Although the data indicated some statistical bias depending on site conditions and type of GPS data used, these biases were typically about 0.5% or less. An assessment of differential correction sources was limited by a lack of data collected in a range of different correction sources and different GPS receivers at the same sites. Despite this limitation, the data indicate that the use of Wide Area Augmentation System (WAAS) corrected positional data is acceptable for discharge measurements using GGA as the boat-velocity reference. The discharge data based on GPS-referenced boat velocities from the VTG data string, which does not require differential correction, were comparable to the discharges based on GPS-referenced boat velocities from the differentially-corrected GGA data string. Spatial variability of measure discharges referenced to GGA, VTG and bottom-tracking is higher near the channel banks. The spatial variability of VTG-referenced discharges is correlated with the spatial distribution of maximum Horizontal Dilution of Precision (HDOP) values and the spatial variability of GGA-referenced discharges is correlated with proximity to channel banks.

  6. Studies on the Electrical Characteristics of a DC Glow Discharge by Using Langmuir Probe

    International Nuclear Information System (INIS)

    Safaai, S. S.; Yap, S. L.; Wong, C. S.; Muniandy, S. V.; Smith, P. W.

    2010-01-01

    Electrical characteristics of a DC glow discharge are studied with the aim of determining the suitable parameters for stable operation of the dusty plasma system. The presence of dust particles in plasma significantly alters the charged particle equilibrium in the plasma and leads to various phenomena. Argon plasma produced by DC glow discharge is investigated with a further goal of studying dusty plasma phenomena. The discharge system has two disc-shaped parallel plate electrodes. The electrodes are enclosed in a large cylindrical stainless steel chamber filled with argon gas. Two important physical parameters affecting the condition of the discharge are the gas pressure and the inter-electrode distance. A single Langmuir probe based on the Keithley source meter is used to determine the electron temperature of the positive column. A custom designed probe is employed to determine the potential distribution between the electrodes during the discharge. The I-V characteristic curve and the Langmuir probe measurement are then used to determine the electron energy distribution of the glow discharge plasma.

  7. Mode conversion and its utilization of degenerating surface wave modes on a plasma column

    International Nuclear Information System (INIS)

    Nonaka, S.; Akao, Y.

    1983-01-01

    Both mode conversion at degenerating points of dispersion relations for surface wave modes on a discharge plasma column and the methods for their detection and utilization are presented. Mode conversions at three degenerating points become observable by using a surface wave resonator when an azimuthal inhomogeneity of plasma is produced by a static magnetic field of about 1 G applied perpendicular to the column axis. Two of the three detected degenerating points can be utilized for an easy and exact determination of the electron density and its distribution in the discharge tube

  8. Extreme degree of ionization in homogenous micro-capillary plasma columns heated by ultrafast current pulses.

    Science.gov (United States)

    Avaria, G; Grisham, M; Li, J; Tomasel, F G; Shlyaptsev, V N; Busquet, M; Woolston, M; Rocca, J J

    2015-03-06

    Homogeneous plasma columns with ionization levels typical of megaampere discharges are created by rapidly heating gas-filled 520-μm-diameter channels with nanosecond rise time current pulses of 40 kA. Current densities of up to 0.3  GA cm^{-2} greatly increase Joule heating with respect to conventional capillary discharge Z pinches, reaching unprecedented degrees of ionization for a high-Z plasma column heated by a current pulse of remarkably low amplitude. Dense xenon plasmas are ionized to Xe^{28+}, while xenon impurities in hydrogen discharges reach Xe^{30+}. The unique characteristics of these hot, ∼300:1 length-to-diameter aspect ratio plasmas allow the observation of unexpected spectroscopic phenomena. Axial spectra show the unusual dominance of the intercombination line over the resonance line of He-like Al by nearly an order of magnitude, caused by differences in opacities in the axial and radial directions. These plasma columns could enable the development of sub-10-nm x-ray lasers.

  9. Application of an antenna excited high pressure microwave discharge to compact discharge lamps

    International Nuclear Information System (INIS)

    Kando, M; Fukaya, T; Ohishi, Y; Mizojiri, T; Morimoto, Y; Shido, M; Serita, T

    2008-01-01

    A novel type of high pressure microwave discharge has been investigated to feed the microwave power at the centre of the compact high pressure discharge lamps using the antenna effect. This method of microwave discharge is named as the antenna excited microwave discharge (AEMD). The 2.45 GHz microwave of around 50 W from the solid state microwave generator can sustain a stable plasma column in the small gap between a couple of antennas fitted on the compact lamp filled with discharge gases at a pressure higher than atmosphere. The AEMD has been applied to a compact metal halide lamp and an extremely high pressure mercury discharge lamp. As a result, the metal halide lamp showed high luminous efficacy of around 130 lm W -1 . The excellent lamp properties obtained here can be explained by the low heating loss at the antennas and the lamp wall. The profiles of the microwave electric field in the lamp and the microwave launcher have been numerically calculated to consider the microwave power supply into the lamp

  10. CO-AXIAL DISCHARGES

    Science.gov (United States)

    Luce, J.S.; Smith, L.P.

    1960-11-22

    A method and apparatus are given for producing coaxial arc discharges in an evacuated enclosure and within a strong, confining magnetic field. The arcs are maintained at a high potential difference. Electrons will diffuse to the more positive arc from the negative arc, and positive ions will diffuse from the more positive arc to the negative arc. Coaxial arc discharges have the advantage that ions which return to strike the positive arc discharge will lose no energy since they do not strike a solid wall or electrode. Those discharges are useful in confining an ionized plasma between the discharges, and have the advantage of preventing impurities from the walls of the enclosure from entering ihe plasma area because of the arc barrier set up bv the cylindrical outer arc.

  11. Spatiotemporally resolved characteristics of a gliding arc discharge in a turbulent air flow at atmospheric pressure

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2017-01-01

    A gliding arc discharge was generated in a turbulent air flow at atmospheric pressure driven by a 35 kHz alternating current (AC) electric power. The spatiotemporally resolved characteristics of the gliding arc discharge, including glow-type discharges, spark-type discharges, short-cutting events...... and transitions among the different types of discharges, were investigated using simultaneously optical and electrical diagnostics. The glow-type discharge shows sinusoidal-like voltage and current waveforms with a peak current of hundreds of milliamperes. The frequency of the emission intensity variation...... of the glow-type discharge is the same as that of the electronic power dissipated in the plasma column. The glow-type discharge can transfer into a spark discharge characterized by a sharp peak current of several amperes and a sudden increase of the brightness in the plasma column. Transitions can also...

  12. Numerical and Experimental Study of Amplitude Modulated Positive Corona Discharge

    Directory of Open Access Journals (Sweden)

    Pablo Martín GOMEZ

    2014-12-01

    Full Text Available The electrical behavior of a modulated positive corona discharge loudspeaker was studied. A coaxial transducer in air was built using a central copper wire of 75 mm radius (inner electrode and a perforated tube of 11 mm (outer electrode. A high voltage DC supply provided the bias current and a sinusoidal signal was superimposed to measure the discharge admittance. The experimental results could not be matched to previously reported equivalent circuits with fixed components. Using the basic equations that describe the ion motion, a numerical model was proposed. The computed values matched well the experimental data and suggested an equivalent circuit composed of frequency dependent conductance and capacitance. This dependence is closely related to the ion travel time between electrodes (transit time. Simulations carried out at several inter-electrode distances could be synthesized in a single plot where the different results overlap and further emphasize the role of the transit time. This numerical model proved to be an efficient tool to simulate and design modulated corona transducers.

  13. Sustained diffusive alternating current gliding arc discharge in atmospheric pressure air

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Li, Zhongshan

    2014-01-01

    Rapid transition from glow discharge to thermal arc has been a common problem in generating stable high-power non-thermal plasmas especially at ambient conditions. A sustained diffusive gliding arc discharge was generated in a large volume in atmospheric pressure air, driven by an alternating...... current (AC) power source. The plasma column extended beyond the water-cooled stainless steel electrodes and was stabilized by matching the flow speed of the turbulent air jet with the rated output power. Comprehensive investigations were performed using high-speed movies measured over the plasma column...

  14. United States Geological Survey discharge data from five example gages on intermittent streams

    Data.gov (United States)

    U.S. Environmental Protection Agency — The data are mean daily discharge data at United States Geological Survey gages. Once column provides the date (mm/dd/yyyy) and the other column provides the mean...

  15. Dimensional analysis of detrimental ozone generation by positive wire-to-plate corona discharge in air

    Science.gov (United States)

    Bo, Z.; Chen, J. H.

    2010-02-01

    The dimensional analysis technique is used to formulate a correlation between ozone generation rate and various parameters that are important in the design and operation of positive wire-to-plate corona discharges in indoor air. The dimensionless relation is determined by linear regression analysis based on the results from 36 laboratory-scale experiments. The derived equation is validated by experimental data and a numerical model published in the literature. Applications of such derived equation are illustrated through an example selection of the appropriate set of operating conditions in the design/operation of a photocopier to follow the federal regulations of ozone emission. Finally, a new current-voltage characteristic equation is proposed for positive wire-to-plate corona discharges based on the derived dimensionless equation.

  16. Dimensional analysis of detrimental ozone generation by positive wire-to-plate corona discharge in air

    International Nuclear Information System (INIS)

    Bo, Z; Chen, J H

    2010-01-01

    The dimensional analysis technique is used to formulate a correlation between ozone generation rate and various parameters that are important in the design and operation of positive wire-to-plate corona discharges in indoor air. The dimensionless relation is determined by linear regression analysis based on the results from 36 laboratory-scale experiments. The derived equation is validated by experimental data and a numerical model published in the literature. Applications of such derived equation are illustrated through an example selection of the appropriate set of operating conditions in the design/operation of a photocopier to follow the federal regulations of ozone emission. Finally, a new current-voltage characteristic equation is proposed for positive wire-to-plate corona discharges based on the derived dimensionless equation.

  17. Separation analysis of macrolide antibiotics with good performance on a positively charged C18HCE column.

    Science.gov (United States)

    Wei, Jie; Shen, Aijin; Yan, Jingyu; Jin, Gaowa; Yang, Bingcheng; Guo, Zhimou; Zhang, Feifang; Liang, Xinmiao

    2016-03-01

    The separation of basic macrolide antibiotics suffers from peak tailing and poor efficiency on traditional silica-based reversed-phase liquid chromatography columns. In this work, a C18HCE column with positively charged surface was applied to the separation of macrolides. Compared with an Acquity BEH C18 column, the C18HCE column exhibited superior performance in the aspect of peak shape and separation efficiency. The screening of mobile phase additives including formic acid, acetic acid and ammonium formate indicated that formic acid was preferable for providing symmetrical peak shapes. Moreover, the influence of formic acid content was investigated. Analysis speed and mass spectrometry compatibility were also taken into account when optimizing the separation conditions for liquid chromatography coupled with tandem mass spectrometry. The developed method was successfully utilized for the determination of macrolide residues in a honey sample. Azithromycin was chosen as the internal standard for the quantitation of spiramycin and tilmicosin, while roxithromycin was used for erythromycin, tylosin, clarithromycin, josamycin and acetylisovaleryltylosin. Good correlation coefficients (r(2) > 0.9938) for all macrolides were obtained. The intra-day and inter-day recoveries were 73.7-134.7% and 80.7-119.7% with relative standard deviations of 2.5-8.0% and 3.9-16.1%, respectively. Outstanding sensitivity with limits of quantitation (S/N ≥ 10) of 0.02-1 μg/kg and limits of detection (S/N ≥ 3) of 0.01-0.5 μg/kg were achieved. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Interpretation of duoplasmatron-type ion sources from a model of the discharge

    International Nuclear Information System (INIS)

    Lejeune, C.

    1971-06-01

    The performance logical improvement of these sources needs a precise knowledge of the emitting ionized medium, on which the whole of the properties is depending. Ion production mechanisms have been studied in the discharge together with their transport towards the extraction hole. The source properties are described, in a new manner, as a function of the discharge modes. The discharge is characterized by the existence of a mode change, related to anode column neutral atom lowering in anode column (arc starvation). The complementarity of probe measurements and the energy spectra analysis of the charges emitted by the anode hole allowed to get the potential axial profile, to discover an electric energetic electron beam extracted from cathodic plasma by the striction shealth potential difference and to determine the electron density radial profile in the anode column. Result analysis allows to get a simple scheme of plasmas and laws controlling them in each of the important modes. The density and potential axial theoretical repartition has been calculated as a function of independent parameters-anode pressure and arc intensity and of three secondary parameters characterizing the energy exchange (electron temperature) and magnetic field topography. The agreement between model predictions and experimental variations for source properties -more specifically gas nature and geometry- allow to give the duoplasmatrons sources similitude rules. The discharge model has allowed to interpret the luminous emission spectra from the anode column. It has been shown theoretically that the peculiar conditions of ionization and excitation allow to use the column as an amplifier medium in the optically field. This plasma has been used successfully as an active medium for an ionic laser in a continuous mode [fr

  19. Characterization of non-endcapped polymeric ODS column for the separation of triacylglycerol positional isomers.

    Science.gov (United States)

    Gotoh, Naohiro; Matsumoto, Yumiko; Yuji, Hiromi; Nagai, Toshiharu; Mizobe, Hoyo; Ichioka, Kenji; Kuroda, Ikuma; Noguchi, Noriko; Wada, Shun

    2010-01-01

    The characteristics of a non-endcapped polymeric ODS column for the resolution of triacylglycerol positional isomers (TAG-PI) were examined using a recycle HPLC-atmospheric pressure chemical ionization/mass spectrometry system. A pair of TAG-PI containing saturated fatty acids at least 12 carbons was separated. Except for TAG-PI containing elaidic acid, pairs of TAG-PI containing three unsaturated fatty acids were not separated, even by recycle runs. These results indicate that the resolution of TAG-PI on a non-endcapped polymeric ODS stationary phase is realized by the recognition of the linear structure of the fatty acid and the binding position of the saturated fatty acid in TAG-PI. Chain length was also an important factor for resolution. This method may be a useful and simple for measuring the abundance ratio of TAG-PI containing saturated fatty acids in natural oils.

  20. The effect of temperature on pulsed positive streamer discharges in air over the range 292 K–1438 K

    Science.gov (United States)

    Ono, Ryo; Ishikawa, Yuta

    2018-05-01

    The effect of temperature on pulsed positive streamer discharges in air is measured by comparing atmospheric-pressure, high-temperature discharges with low-pressure, room-temperature discharges at the same air densities n and discharge voltages. Both discharges have the same reduced electric field E/n, so the differences between the two discharges only depend on the temperature, which is varied from 292 K to 1438 K. Temperature affects the discharge pulse energy most significantly; at 1438 K, the energy of an atmospheric-pressure discharge pulse is approximately 30 times larger than that of the corresponding 20.5 kPa, room-temperature discharge. Temperature also affects the shapes of the streamers when K, but no significant effect is observed for K. There is also no significant temperature effect on the spatially integrated intensity of N2(C–B) emission. However, temperature strongly affects the ratio of the integrated emission intensity to the discharge energy. No effect of the temperature is observed on the propagation velocity of the primary streamer or on the length of the secondary streamer.

  1. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    International Nuclear Information System (INIS)

    Aleksandrov, A. F.; Petrov, A. K.; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B.; Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya.

    2016-01-01

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  2. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, A. F.; Petrov, A. K., E-mail: alpetrov57@gmail.com; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B. [Moscow State University, Faculty of Physics (Russian Federation); Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya. [Research Institute of Precision Engineering (Russian Federation)

    2016-03-15

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  3. FPGA based Fuzzy Logic Controller for plasma position control in ADITYA Tokamak

    International Nuclear Information System (INIS)

    Suratia, Pooja; Patel, Jigneshkumar; Rajpal, Rachana; Kotia, Sorum; Govindarajan, J.

    2012-01-01

    Highlights: ► Evaluation and comparison of the working performance of FLC is done with that of PID Controller. ► FLC is designed using MATLAB Fuzzy Logic Toolbox, and validated on ADITYA RZIP model. ► FLC was implemented on a FPGA. The close-loop testing is done by interfacing FPGA to MATLAB/Simulink. ► Developed FLC controller is able to maintain the plasma column within required range of ±0.05 m and was found to give robust control against various disturbances and faster and smoother response compared to PID Controller. - Abstract: Tokamaks are the most promising devices for obtaining nuclear fusion energy from high-temperature, ionized gas termed as Plasma. The successful operation of tokamak depends on its ability to confine plasma at the geometric center of vacuum vessel with sufficient stability. The quality of plasma discharge in ADITYA Tokamak is strongly related to the radial position of the plasma column in the vacuum vessel. If the plasma column approaches too near to the wall of vacuum vessel, it leads to minor or complete disruption of plasma. Hence the control of plasma position throughout the entire plasma discharge duration is a fundamental requirement. This paper describes Fuzzy Logic Controller (FLC) which is designed for radial plasma position control. This controller is tested and evaluated on the ADITYA RZIP control model. The performance of this FLC was compared with that of Proportional–Integral–Derivative (PID) Controller and the response was found to be faster and smoother. FLC was implemented on a Field Programmable Gate Array (FPGA) chip with the use of a Very High-Speed Integrated-Circuits Hardware Description-Language (VHDL).

  4. Long-Term Charge/Discharge Cycling Stability of MnO2 Aqueous Supercapacitor under Positive Polarization

    KAUST Repository

    Ataherian, Fatemeh; Wu, Nae-Lih

    2011-01-01

    The long-term charge/discharge cycling stability of MnO 2 electrode under positive polarization in aqueous KCl electrolyte has been studied over different potential windows spanning from the open circuit potential to varied higher-end potential

  5. Two-dimensional kinetic analysis on the ionization waves in a low current discharge

    International Nuclear Information System (INIS)

    Yamazaki, Tsutomu; Fujii, Masaharu; Noda, Shozou; Miura, Kousuke; Imazu, Shingo.

    1982-01-01

    In the research on the ionization waves produced in the positive column in a low pressure discharge, theoretical analyses have been made since long ago using mainly the fluid theory. However, the experimental properties that cannot be explained with the fluid theory have been found lately. For example, it has been shown experimentally that the product of longitudinal electric field E and the wavelength lambda of ionization waves becomes some specific values depending on the kinds of gas as one of the characteristics of the ionization waves produced in the positive column plasma in rare gas glow discharge, but these specific values of E-lambda cannot be explained with the fluid theory. In this paper, the perturbation component of electron energy distribution function accompanying ionization waves was derived from a two-dimensional Boltzmann equation which takes the radial non-uniformity into account, to consider the E-lambda values of ionization waves from the relative equation between electron density and the perturbation component of an electric field. The following results were obtained. The relative equation between electron density and the perturbation component of an electric field, which cannot be derived from the fluid theory, was able to be obtained; the values of E-lambda product agreed with the experimental results better than one-dimensional analysis; The steeper the shape of radial potential distribution, the more likely the resonance occurrence and the larger the E-lambda product; and so forth. (Wakatsuki, Y.)

  6. Bent paths of a positive streamer and a cathode-directed spark leader in diffuse discharges preionized by runaway electrons

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Cheng; Shao, Tao, E-mail: st@mail.iee.ac.cn; Wang, Ruixue; Yan, Ping [Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190 (China); Key Laboratory of Power Electronics and Electric Drive, Chinese Academy of Sciences, Beijing 100190 (China); Tarasenko, Viktor F.; Beloplotov, Dmitry V.; Lomaev, Mikhail I.; Sorokin, Dmitry A. [Institute of High Current Electronics, Russian Academy of Science, Tomsk 634055 (Russian Federation); National Research Tomsk State University, 36 Lenin Ave., Tomsk 634050 (Russian Federation)

    2015-03-15

    Diffuse discharges preionized by runaway electrons can produce large-area homogeneous discharges at elevated pressures, which is an intriguing phenomenon in the physics of pulsed discharges. In this paper, runaway-electron-preionized diffuse discharge (REP DD) was obtained in a wide pressure range (0.05–0.25 MPa), and under certain conditions a positive streamer and a cathode-directed spark leader could be observed to propagate at some angles to the applied (background) electric field lines. For a 16-mm gap at an air pressure of 0.08–0.1 MPa, the percentage of pulses in which such propagation is observed is about 5%–50% of their total number, and in the other pulses such bent paths could not be observed because there is even no streamer or cathode-directed spark leader in diffuse discharges. In our opinion, such propagation of the positive streamer and the cathode-directed spark leader at some angle to the background electric field lines owes to different increase rates of the electron density in different regions of the discharge volume under REP DD conditions. Therefore, during the formation of a REP DD, the increase of the electron density is inhomogeneous and nonsimultaneous, resulting in an electron density gradient at the ionization wave front.

  7. Bent paths of a positive streamer and a cathode-directed spark leader in diffuse discharges preionized by runaway electrons

    International Nuclear Information System (INIS)

    Zhang, Cheng; Shao, Tao; Wang, Ruixue; Yan, Ping; Tarasenko, Viktor F.; Beloplotov, Dmitry V.; Lomaev, Mikhail I.; Sorokin, Dmitry A.

    2015-01-01

    Diffuse discharges preionized by runaway electrons can produce large-area homogeneous discharges at elevated pressures, which is an intriguing phenomenon in the physics of pulsed discharges. In this paper, runaway-electron-preionized diffuse discharge (REP DD) was obtained in a wide pressure range (0.05–0.25 MPa), and under certain conditions a positive streamer and a cathode-directed spark leader could be observed to propagate at some angles to the applied (background) electric field lines. For a 16-mm gap at an air pressure of 0.08–0.1 MPa, the percentage of pulses in which such propagation is observed is about 5%–50% of their total number, and in the other pulses such bent paths could not be observed because there is even no streamer or cathode-directed spark leader in diffuse discharges. In our opinion, such propagation of the positive streamer and the cathode-directed spark leader at some angle to the background electric field lines owes to different increase rates of the electron density in different regions of the discharge volume under REP DD conditions. Therefore, during the formation of a REP DD, the increase of the electron density is inhomogeneous and nonsimultaneous, resulting in an electron density gradient at the ionization wave front

  8. Validation of ISTTOK Plasma Position Controller

    International Nuclear Information System (INIS)

    Valcarcel, D. F.; Carvalho, I. S.; Carvalho, B. B.; Fernandes, H.; Silva, C.; Duarte, P.; Duarte, A.; Carvalho, P. J.; Pereira, T.

    2008-01-01

    Active control of plasma position on the ISTTOK tokamak is of extreme importance due to the inherent instability caused by an unfavourable curvature of the external equilibrium magnetic field. The consequences of this instability can be suppressed by applying a dynamic equilibrium field. A digital real-time plasma position control system for ISTTOK has been developed to perform this task. This system uses magnetic measurements to determine the plasma position and feeds the control signal to power supplies that generate the equilibrium fields. After commissioning, the results obtained have shown some discrepancies between the magnetic plasma position reconstruction and several other diagnostics, such as tomography. This discrepancy at some extent is due to the effect of the external magnetic fields on the poloidal magnetic measurements. This work presents a study that addresses this issue. In a future work it will lead to the development of a corrected plasma position algorithm, aiming at obtaining improved performance of plasma discharges and controlled plasma column displacements

  9. Identification of groundwater discharge in Cuddalore coast, Tamil Nadu using radium isotopes

    International Nuclear Information System (INIS)

    Diksha Chawla; Noble Jacob; Mohokar, H.V.

    2014-01-01

    For the optimal exploitation and management of coastal aquifers of Tamil Nadu, it is essential to evaluate the groundwater outflow into the sea also called as submarine groundwater discharge. In this study, radium isotopes ( 223,224 Ra) were employed to understand the groundwater discharge in coastal areas of Cuddalore district, Tamil Nadu. Sea water samples (100 L) were collected from various locations of Cuddalore coast in October 2011 and passed through Mn-impregnated acrylic fiber columns. These acrylic columns were analyzed for 223,224 Ra activities using radium delayed coincidence counter. The observed higher activities of 223,224 Ra excess (0.02 ± 0.001-3.28 ± 0.16 and 64 ± 3-380 ± 19 mBq/100 L respectively) indicate that groundwater discharge occurs in this coastal region. (author)

  10. State waste discharge permit application: Hydrotest, maintenance and construction discharges. Revision 0

    International Nuclear Information System (INIS)

    1995-11-01

    On December 23, 1991, the US DOE< Richland Operation Office (RL) and the Washington State Department of Ecology (Ecology) agreed to adhere to the provisions of the Department of Ecology Consent Order No. DE91NM-177 (216 Consent Order) (Ecology and US DOE 1991). The 216 Consent Order list regulatory milestones for liquid effluent streams at the Hanford Site and requires compliance with the permitting requirements of Washington Administrative Code. Hanford Site liquid effluent streams discharging to the soil column have been categorized on the 216 Consent Order as follows: Phase I Streams; Phase II Streams; Miscellaneous Streams. Phase I and Phase II Streams were initially addressed in two report. Miscellaneous Streams are subject to the requirements of several milestones identified in the 216 Consent Order. This document constitutes the Categorical State Waste Discharge Permit application for hydrotest,maintenance and construction discharges throughout the Hanford Site. This categorical permit application form was prepared and approved by Ecology

  11. State waste discharge permit application: Hydrotest, maintenance and construction discharges. Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    On December 23, 1991, the US DOE< Richland Operation Office (RL) and the Washington State Department of Ecology (Ecology) agreed to adhere to the provisions of the Department of Ecology Consent Order No. DE91NM-177 (216 Consent Order) (Ecology and US DOE 1991). The 216 Consent Order list regulatory milestones for liquid effluent streams at the Hanford Site and requires compliance with the permitting requirements of Washington Administrative Code. Hanford Site liquid effluent streams discharging to the soil column have been categorized on the 216 Consent Order as follows: Phase I Streams; Phase II Streams; Miscellaneous Streams. Phase I and Phase II Streams were initially addressed in two report. Miscellaneous Streams are subject to the requirements of several milestones identified in the 216 Consent Order. This document constitutes the Categorical State Waste Discharge Permit application for hydrotest,maintenance and construction discharges throughout the Hanford Site. This categorical permit application form was prepared and approved by Ecology.

  12. Ozone generation in positive and negative corona discharge fed by humid oxygen and carbon dioxide

    International Nuclear Information System (INIS)

    Skalny, J D; Orszagh, J; MatejcIk, S; Mason, N J

    2008-01-01

    The effect of humidity on ozone generation of positive and negative corona discharges fed by O 2 and CO 2 has been studied in the humidity range of 100-20 000 ppm. The experiments were carried out at an ambient temperature and pressure of 100 kPa. The increase in humidity of CO 2 conspicuously suppressed the ozone generation in negative corona discharge at all values of the input energy densities into the discharge. The effect was less pronounced in oxygen. In contrast to decrease of ozone concentration observed in negative corona discharge, the presence of water both in O 2 and CO 2 acts catalytically. The ozone concentration has been found to increase remarkably (approximately 10 times) in oxygen, if the humidity was increased from 100 to 20 000 ppm. The dependence of ozone concentration on the gas humidity exhibited an extreme. The increase observed at humidity up to approximately 5000 ppm was followed by the marginal reduction in ozone concentration. Anyway, the values of this were considerably higher than those found in dry CO 2 . The effect of humidity on ozone concentration will be discussed in relation to plasma chemical processes in studied discharges and their macroscopic parameters.

  13. Cylindrical stationary striations in surface wave produced plasma columns of argon

    Science.gov (United States)

    Kumar, Rajneesh; Kulkarni, Sanjay V.; Bora, Dhiraj

    2007-12-01

    Striations are a good example of manifestation of a glow discharge. In the present investigation, stationary striations in the surface wave produced plasma column are formed. Physical parameters (length, number, etc.) of such striations can be controlled by operating parameters. With the help of bifurcation theory, experimental results are explained by considering two-step ionization in the surface wave discharge mechanism in argon gas. It is also observed that the bifurcation parameter is a function of input power, working pressure, and tube radius.

  14. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  15. Two-dimensional simulation of the development of an inhomogeneous volume discharge in a Ne/Xe/HCl gas mixture

    International Nuclear Information System (INIS)

    Bychkov, Yu. I.; Yampolskaya, S. A.; Yastremskii, A. G.

    2013-01-01

    The kinetic processes accompanying plasma column formation in an inhomogeneous discharge in a Ne/Xe/HCl gas mixture at a pressure of 4 atm were investigated by using a two-dimensional model. Two cathode spots spaced by 0.7 cm were initiated by distorting the cathode surface at local points, which resulted in an increase in the field strength in the cathode region. Three regimes differing in the charging voltage, electric circuit inductance, and electric field strength at the local cathode points were considered. The spatiotemporal distributions of the discharge current; the electron density; and the densities of excited xenon atoms, HCl(v = 0) molecules in the ground state, and HCl(v > 0) molecules in vibrational levels were calculated. The development of the discharge with increasing the electron density from 10 4 to 10 16 cm −3 was analyzed, and three characteristic stages in the evolution of the current distribution were demonstrated. The width of the plasma column was found to depend on the energy deposited in the discharge. The width of the plasma column was found to decrease in inverse proportion to the deposited energy due to spatiotemporal variations in the rates of electron production and loss. The calculated dependences of the cross-sectional area of the plasma column on the energy deposited in the discharge agree with the experimental results.

  16. Conceptual design of plasma position control of SST-1 tokamak using vertical field coil

    International Nuclear Information System (INIS)

    Gulati, Hitesh Kumar; Patel, Kiritkumar B.; Dhongde, Jasraj

    2015-01-01

    SST-1 (Steady State Superconducting Tokamak) is a plasma confinement device in Institute for Plasma Research (IPR) India. SST-1 has been commissioned successfully and has been carrying out plasma experiments since the beginning of 2014 achieved a maximum plasma current of 75 kA at a central field of 1.5 T and the plasma duration ∼ 500 ms. SST-1 looks forward to carrying out elongated plasma experiments and stretching plasma pulses beyond 1s. Based on the solution of Grad-Shafranov equation the shift of plasma column center from geometrical centre of vacuum chamber is measured using various magnetic probes and flux loops installed in the machine. The closed feedback loop uses plasma current (Ip), Delta R as feedback signal and manipulate the vertical field current (Ivf). The discharge starts with feed forward loop using initially provided reference then the active feedback starts after discharge by few msec once plasma column is completely formed. The feedback loop time is of the order of 10 msec. The primary objective is to acquire plasma position control related signals, compute plasma position and generate position correction signal for VF coil power supply, communicate correction to VF coil power supply and modify VF power supply output in a deterministic time span. In this we present the methodology used for plasma horizontal displacement control using vertical field and discuss the preliminary results. (author)

  17. RETENTION TIME EFFECT ON METAL REMOVAL BY PEAT COLUMNS

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, E

    2007-02-28

    The potential use of a peat bed to treat the H-12 Outfall discharge to bring it to new compliance limits was previously investigated and reported utilizing a 7 hour retention time. The influence of retention time (contact time) of water with peat moss on the removal of copper from the water was investigated under laboratory conditions using vertical flow peat moss columns. Reduction of the necessary retention time has a large influence on the design sizing of any peat bed that would be constructed to treat the H-12 discharge on a full scale basis. Retention times of 5 hours, 3 hours and 1 hour were tested to determine the copper removal by the peat columns using vertical flow. Water samples were collected after 4, 8, 12, and 16 water volumes had passed through the columns and analyzed for a suite of metals, with quantitative emphasis on copper. Laboratory results indicated that copper removal was very high at each of the 3 retention times tested, ranging from 99.6 % removal at 5 and 3 hours to 98.8% removal at 1 hour. All these values are much lower that the new compliance limit for the outfall. The results also indicated that most divalent metals were removed to their normal reporting detection limit for the analytical methods used, including zinc. Lead levels in the H-12 discharge used in this study were below PQL in all samples analyzed. While each of the retention times studied removed copper very well, there were indications that 1 hour is probably too short for an operational, long-term facility. At that retention time, there was about 6% compaction of the peat in the column due to the water velocity, and this may affect long term hydraulic conductivity of the peat bed. At that retention time, copper concentration in the effluent was higher than the other times tested, although still very low. Because of the potential compacting and somewhat reduced removal efficiency at a 1 hour retention time, it would be prudent to design to at least a 3 hour retention

  18. Full spatial-field visualization of gas temperature in an air micro-glow discharge by calibrated Schlieren photography

    Science.gov (United States)

    Xiong, Qing; Xu, Le; Wang, Xia; Xiong, Lin; Huang, Qinghua; Chen, Qiang; Wang, Jingang; Peng, Wenxiong; Li, Jiarui

    2018-03-01

    Gas temperature is an important basic parameter for both fundamental research and applications of plasmas. In this work, efforts were made to visualize the full spatial field of gas temperature (T g) in a microdischarge with sharp T g gradients by a method of calibrated Schlieren (CS) photography. Compared to other two typical diagnostic approaches, optical emission spectroscopy (OES) and Rayleigh scattering, the proposed CS method exhibits the ability to capture the whole field of gas temperature using a single Schlieren image, even the discharge is of non-luminous zones like Faraday dark space (FDS). The image shows that the T g field in the studied micro-glow air discharge expands quickly with the increase of discharge currents, especially in the cathode region. The two-dimensional maps of gas temperature display a ‘W-shape’ with sharp gradients in both areas of negative and positive glows, slightly arched distributions in the positive column, and cooling zones in the FDS. The obtained T g fields show similar patterns to that of the discharge luminance. With an increase in discharge currents, more electric energy is dissipated by heating air gas and inducing constriction of the low-temperature FDS. Except in the vicinities of electrode boundaries, due to the interference from optical diffraction, the estimated gas temperature distributions are of acceptable accuracy, confirmed by the approaches of OES and UV Rayleigh scattering.

  19. Varied overstrain injuries of the vertebral column conditioned by evolution

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbach, W

    1983-08-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components.

  20. Varied overstrain injuries of the vertebral column conditioned by evolution

    International Nuclear Information System (INIS)

    Kohlbach, W.

    1983-01-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components. (orig.) [de

  1. Measurement of gas temperature and OH density in the afterglow of pulsed positive corona discharge

    International Nuclear Information System (INIS)

    Ono, Ryo; Oda, Tetsuji

    2008-01-01

    The gas temperature and OH density in the afterglow of pulsed positive corona discharge are measured using the laser-induced predissociation fluorescence (LIPF) of OH radicals. Discharge occurs in a 13 mm point-to-plane gap in an atmospheric-pressure H 2 O(2.8%)/O 2 (2.0%)/N 2 mixture. The temperature measurement shows that (i) the temperature increases after discharge and (ii) the temperature near the anode tip (within 1 mm from the anode tip) is much higher than that of the rest of the discharge volume. Near the anode tip, the temperature increases from 500 K (t = 0 μs) to 1100 K (t = 20 μs), where t is the postdischarge time, while it increases from 400 K (t = 0 μs) to 700 K (t = 100 μs) in the rest of the discharge volume away from the anode tip. This temperature difference between the two volumes (near and far from the anode tip) causes a difference in the decay rate of OH density: OH density near the anode tip decays approximately 10 times slower than that far from the tip. The spatial distribution of OH density shows good agreement with that of the secondary streamer luminous intensity. This shows that OH radicals are mainly produced in the secondary streamer, not in the primary one

  2. Experiments on toroidal inductively coupled alternating-current gas discharges

    International Nuclear Information System (INIS)

    Lok, J.

    1976-01-01

    This report is on an experimental study of a toroidal, inductively coupled a.c. gas discharge sustained at pressures roughly between one tenth of a Torr and some tens of Torrs. After breakdown is obtained at low pressure, additional gas is let in. The energy is inductively coupled into the electrodeless discharge by means of an iron core transformer of which the toroidal plasma column is the secondary winding. The power dissipated in the plasma is between 80 and 260 kW and is delivered by a motor-generator system at a frequency of 8 kHz for times up to 2 seconds. A toroidal magnetic field of 0.5 T maximum can be supplied in a short pulse. Five different gases (hydrogen, deuterium, helium, argon, and nitrogen) are used. The pressure range in which the discharges are sustained is specified, and the dynamic current-voltage characteristics are given for different pressures. Some typical streak pictures with simultaneously obtained recordings of the time behaviour of the discharge current and of the loop voltage are presented for the initial phase - at low pressure - of the discharge. The shape and the position of fully developed discharges at various pressures are discussed on the basis of photographic observations. The temperature of hydrogen plasmas is derived both from the electrical conductivity and from the emission of line radiation. The values of the temperature obtained in these ways differ in magnitude and in time behaviour. A possible explanation of the discrepancy can be obtained in terms of expansion and contraction of electron density and temperature profiles during a period of the discharge current, if it is taken into account that the main part of the light emission always originates from the outer colder regions of the plasma. In a somewhat different pressure regime, this picture is confirmed by microwave measurements

  3. Faraday space in a high-frequency γ discharge and the influence of pressure on the normal current density effect of an α discharge and the nature of the α-γ transition

    International Nuclear Information System (INIS)

    Raizer, Yu.P.; Shneider, M.N.

    1992-01-01

    The essential differences between high-frequency capacative discharges at intermediate and low pressures are considered. A theory is developed for the negative emission region and the Faraday dark space in a γ discharge. It is based on the kinetic equation for electrons in the highly nonuniform field of an electrode sheath, which is solved in the forward-backward approximation. If a uniform positive column is formed in the middle of the gap of a γ discharge of average pressure which is not too short, then at low pressures the hf plasma acts as the equivalent of the negative emission or Faraday space of a glow discharge with a typical weak field and low electron temperature. A region of reversed average field also appears, which is characteristic of a glow discharge. The question of the normal current density effect in an α discharge is discussed. This effect is observed at average pressures. At low pressures the effect disappears, and even weak current covers the entire electrode; the pressures at which this occurs and the reasons for it are demonstrated. The nature of the α-γ transition, which takes place discontinuously at average pressures but continuously at lower pressures, is discussed. The reason for this behavior is discussed and the pressure at which the discontinuous mechanism changes into continuous is estimated

  4. Exhaust properties of centre-column-limited plasmas on MAST

    International Nuclear Information System (INIS)

    Maddison, G.P.; Akers, R.J.; Brickley, C.; Gryaznevich, M.P.; Lott, F.C.; Patel, A.; Sykes, A.; Turner, A.; Valovic, M.

    2007-01-01

    The lowest aspect ratio possible in a spherical tokamak is defined by limiting the plasma on its centre column, which might therefore maximize many physics benefits of this fusion approach. A key issue for such discharges is whether loads exhausted onto the small surface area of the column remain acceptable. A first series of centre-column-limited pulses has been examined on MAST using fast infra-red thermography to infer incident power densities as neutral-beam heating was scanned from 0 to 2.5 MW. Simple mapping shows that efflux distributions on the column armour are governed mostly by magnetic geometry, which moreover spreads them advantageously over almost the whole vertical length. Hence steady peak power densities between sawteeth remained low, -2 , comparable with the target strike-point value in a reference diverted plasma at lower power. Plasma purity and normalized thermal energy confinement through the centre-column-limited (CCL) series were also similar to properties of MAST diverted cases. A major bonus of CCL geometry is a propensity for exhaust to penetrate through its inner scrape-off layer connecting to the column into an expanding outer plume, which forms a 'natural divertor'. Effectiveness of this process may even increase with plasma heating, owing to rising Shafranov shift and/or toroidal rotation. A larger CCL device could potentially offer a simpler, more economic next-step design

  5. Faraday space in a glow discharge with uniform cross section and one expanding from the cathode to the positive column

    International Nuclear Information System (INIS)

    Raizer, Y.P.; Shneider, M.N.

    1992-01-01

    A simplified asymptotic theory is used to find the distribution of the field and plasma density and to estimate the length of the Faraday dark space in a glow discharge in slab geometry and in one where the transverse cross section of the drift tube increases as a function of distance from the cathode. It is shown that the Faraday space is longer in the second case. The effects and behavior observed experimentally, including field reversal, are fully explained on the basis of the diffusive mechanism for charge transport in a very weak field without the inverse dependence of the electron mobility on the field that has been assumed in many treatments. 7 refs., 5 figs

  6. Two-Dimensional Electron Density Measurement of Positive Streamer Discharge in Atmospheric-Pressure Air

    Science.gov (United States)

    Inada, Yuki; Ono, Ryo; Kumada, Akiko; Hidaka, Kunihiko; Maeyama, Mitsuaki

    2016-09-01

    The electron density of streamer discharges propagating in atmospheric-pressure air is crucially important for systematic understanding of the production mechanisms of reactive species utilized in wide ranging applications such as medical treatment, plasma-assisted ignition and combustion, ozone production and environmental pollutant processing. However, electron density measurement during the propagation of the atmospheric-pressure streamers is extremely difficult by using the conventional localized type measurement systems due to the streamer initiation jitters and the irreproducibility in the discharge paths. In order to overcome the difficulties, single-shot two-dimensional electron density measurement was conducted by using a Shack-Hartmann type laser wavefront sensor. The Shack-Hartmann sensor with a temporal resolution of 2 ns was applied to pulsed positive streamer discharges generated in an air gap between pin-to-plate electrodes. The electron density a few ns after the streamer initiation was 7*1021m-3 and uniformly distributed along the streamer channel. The electron density and its distribution profile were compared with a previous study simulating similar streamers, demonstrating good agreement. This work was supported in part by JKA and its promotion funds from KEIRIN RACE. The authors like to thank Mr. Kazuaki Ogura and Mr. Kaiho Aono of The University of Tokyo for their support during this work.

  7. Varied overstrain injuries of the vertebral column conditioned by evolution

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbach, W.

    1983-08-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components.

  8. Implications of soil mixing for NAPL source zone remediation: Column studies and modeling of field-scale systems.

    Science.gov (United States)

    Olson, Mitchell R; Sale, Tom C

    2015-01-01

    Soil remediation is often inhibited by subsurface heterogeneity, which constrains contaminant/reagent contact. Use of soil mixing techniques for reagent delivery provides a means to overcome contaminant/reagent contact limitations. Furthermore, soil mixing reduces the permeability of treated soils, thus extending the time for reactions to proceed. This paper describes research conducted to evaluate implications of soil mixing on remediation of non-aqueous phase liquid (NAPL) source zones. The research consisted of column studies and subsequent modeling of field-scale systems. For column studies, clean influent water was flushed through columns containing homogenized soils, granular zero valent iron (ZVI), and trichloroethene (TCE) NAPL. Within the columns, NAPL depletion occurred due to dissolution, followed by either column-effluent discharge or ZVI-mediated degradation. Complete removal of TCE NAPL from the columns occurred in 6-8 pore volumes of flow. However, most of the TCE (>96%) was discharged in the column effluent; less than 4% of TCE was degraded. The low fraction of TCE degraded is attributed to the short hydraulic residence time (10 m) and reducing permeability by one-or-more orders of magnitude, the residence time could be greatly extended, potentially for periods of years to decades. Model output indicates that the fraction of TCE degraded can be increased to >99.9%, given typical post-mixing soil permeability values. These results suggest that remediation performance can be greatly enhanced by combining contaminant degradation with an extended residence time. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. A stochastic view on column efficiency.

    Science.gov (United States)

    Gritti, Fabrice

    2018-03-09

    A stochastic model of transcolumn eddy dispersion along packed beds was derived. It was based on the calculation of the mean travel time of a single analyte molecule from one radial position to another. The exchange mechanism between two radial positions was governed by the transverse dispersion of the analyte across the column. The radial velocity distribution was obtained by flow simulations in a focused-ion-beam scanning electron microscopy (FIB-SEM) based 3D reconstruction from a 2.1 mm × 50 mm column packed with 2 μm BEH-C 18 particles. Accordingly, the packed bed was divided into three coaxial and uniform zones: (1) a 1.4 particle diameter wide, ordered, and loose packing at the column wall (velocity u w ), (2) an intermediate 130 μm wide, random, and dense packing (velocity u i ), and (3) the bulk packing in the center of the column (velocity u c ). First, the validity of this proposed stochastic model was tested by adjusting the predicted to the observed reduced van Deemter plots of a 2.1 mm × 50 mm column packed with 2 μm BEH-C 18 fully porous particles (FPPs). An excellent agreement was found for u i  = 0.93u c , a result fully consistent with the FIB-SEM observation (u i  = 0.95u c ). Next, the model was used to measure u i  = 0.94u c for 2.1 mm × 100 mm column packed with 1.6 μm Cortecs-C 18 superficially porous particles (SPPs). The relative velocity bias across columns packed with SPPs is then barely smaller than that observed in columns packed with FPPs (+6% versus + 7%). u w =1.8u i is measured for a 75 μm × 1 m capillary column packed with 2 μm BEH-C 18 particles. Despite this large wall-to-center velocity bias (+80%), the presence of the thin and ordered wall packing layer has no negative impact on the kinetic performance of capillary columns. Finally, the stochastic model of long-range eddy dispersion explains why analytical (2.1-4.6 mm i.d.) and capillary (columns can all be

  10. Quantitative atom column position analysis at the incommensurate interfaces of a (PbS)1.14NbS2 misfit layered compound with aberration-corrected HRTEM

    International Nuclear Information System (INIS)

    Garbrecht, M.; Spiecker, E.; Tillmann, K.; Jaeger, W.

    2011-01-01

    Aberration-corrected HRTEM is applied to explore the potential of NCSI contrast imaging to quantitatively analyse the complex atomic structure of misfit layered compounds and their incommensurate interfaces. Using the (PbS) 1.14 NbS 2 misfit layered compound as a model system it is shown that atom column position analyses at the incommensurate interfaces can be performed with precisions reaching a statistical accuracy of ±6 pm. The procedure adopted for these studies compares experimental images taken from compound regions free of defects and interface modulations with a structure model derived from XRD experiments and with multi-slice image simulations for the corresponding NCSI contrast conditions used. The high precision achievable in such experiments is confirmed by a detailed quantitative analysis of the atom column positions at the incommensurate interfaces, proving a tetragonal distortion of the monochalcogenide sublattice. -- Research Highlights: → Quantitative aberration-corrected HRTEM analysis of atomic column positions in (PbS) 1.14 NbS 2 misfit layered compound reveals tetragonal distortion of the PbS subsystem. → Detailed comparison of multi-slice simulations with the experimental NCSI contrast condition imaging results lead to a high precision (better than 10 pm) for determining the positions of atoms. → Precision in gaining information of local structure at atomic scale is demonstrated, which may not be accessible by means of X-ray and neutron diffraction analysis.

  11. Identification of groundwater discharge in Cuddalore Coast, Tamil Nadu using radium isotopes

    International Nuclear Information System (INIS)

    Diksha; Jacob, Noble; Mohokar, H.V.

    2013-01-01

    For the optimal exploitation and management of coastal aquifers of Tamil Nadu, it is essential to evaluate the groundwater outflow into the sea. In this study, radium isotopes ( 223,224 Ra) were employed to understand the groundwater discharge in coastal areas of Cuddalore district, Tamil Nadu. Sea water samples (100 L) were collected from various locations of Cuddalore coast in October 2011 and passed through Mn-impregnated acrylic fiber columns. These acrylic columns were analyzed for 223,224 Ra activities using Radium Delayed Coincidence Counter (RaDeCC). The observed higher activities of 223,224 Ra (0-0.18 and 3.84-22.77 dpm/L respectively) indicate that groundwater discharge occurs in this coastal region. (author)

  12. Conditions for sustaining low-pressure plasma columns by travelling electromagnetic UHF waves

    International Nuclear Information System (INIS)

    Benova, E.; Zhelyazkov, I.

    1997-01-01

    The paper considers the conditions for sustaining low-pressure plasma columns by travelling electromagnetic waves in symmetric and dipolar modes, respectively. The treatment is fully electrodynamic. It is shown that the wave energy flux along the plasma column determines the conditions for sustaining the discharge. In particular as the plasma is sustained by a symmetric wave whose flux depends mainly on the radial distribution of the wave electric field whilst for a dipolar wave sustained plasma the flux is specified by the magnitude of the axial wave field component at the plasma-dielectric interface. (orig.)

  13. Study of the striated nature of a glow discharge

    International Nuclear Information System (INIS)

    Hernandez A, M.

    1995-01-01

    In an investigation in progress here, plasma diagnostics and detection of standing and moving striations is being made in a discharge in Argon at pressures of 2 x 10 -1 to 9 x 10 -1 mb and currents of 2 to 9 m-amp inside an discharge tube. Measurement of the temperature of the electrons, the concentration of electrons and the plasma potential are obtained in different places of the discharge by the double probe method, together with the computation system reported in [1]. In similar way an experimental work of the striated column in a discharge plasma to find the regimen of appearance of the standing and moving striations show some properties of moving striations (frequency and velocity) and standing striations. Two different oscilations are observed in motion in contrary directions along the discharge tube with a photomultiplier. (Author)

  14. High pressure microwave discharge for electrodeless Xe-lamp

    International Nuclear Information System (INIS)

    Kudela, J.; Kando, M.

    1998-01-01

    Preliminary results are presented of the investigation into the high pressure Xe microwave discharge in bent tubes, sustained by electromagnetic surface wave. The research was aimed to help with the design of a new generation of high intensity light sources with generally more complex shapes than those commonly used. The results show that the electromagnetic surface wave can effectively sustain discharge in tubes with various bending radii within the large pressure range. The curved shapes of discharge tubes improve the cooling of the lamp which is one of the major technological difficulties. It was shown that under relatively lower powers and higher gas pressures (100 Torr) the discharge exhibits a streamer-like filamentation and the branching of filaments. The phenomena of the effective sustaining of the discharge by surface wave propagation along curved plasma columns will be investigated in more detail by measurements of the profiles of surface wave electric and magnetic field intensities. (author)

  15. Discharge measurements at gaging stations

    Science.gov (United States)

    Turnipseed, D. Phil; Sauer, Vernon B.

    2010-01-01

    The techniques and standards for making discharge measurements at streamflow gaging stations are described in this publication. The vertical axis rotating-element current meter, principally the Price current meter, has been traditionally used for most measurements of discharge; however, advancements in acoustic technology have led to important developments in the use of acoustic Doppler current profilers, acoustic Doppler velocimeters, and other emerging technologies for the measurement of discharge. These new instruments, based on acoustic Doppler theory, have the advantage of no moving parts, and in the case of the acoustic Doppler current profiler, quickly and easily provide three-dimensional stream-velocity profile data through much of the vertical water column. For much of the discussion of acoustic Doppler current profiler moving-boat methodology, the reader is referred to U.S. Geological Survey Techniques and Methods 3-A22 (Mueller and Wagner, 2009). Personal digital assistants (PDAs), electronic field notebooks, and other personal computers provide fast and efficient data-collection methods that are more error-free than traditional hand methods. The use of portable weirs and flumes, floats, volumetric tanks, indirect methods, and tracers in measuring discharge are briefly described.

  16. Relaxation of atomic state multipoles by radiation re-absorption: Neon 2p2 atoms in a discharge plasma

    International Nuclear Information System (INIS)

    Nimura, M.; Imagawa, T.; Hasuo, M.; Fujimoto, T.

    2005-01-01

    In a positive column of a glow discharge in the magnetic field of 36.4G, a linearly polarized laser pulse or a circularly polarized laser pulse has produced polarized neon atoms (alignment or orientation) in the 2p 2 (Paschen notation) level from the 1s 3 level. The subsequent fluorescence to the 1s 2 level was observed with its polarized components resolved. Depopulation, disorientation and disalignment rates of the 2p 2 atom were measured and their discharge current dependences were examined for a discharge current from 0.4 to 2.0mA. The degrees of radiation re-absorption, or the optical thickness, of the transition lines from the 2p 2 level to the 1s 2 -1s 5 levels were measured as functions of the discharge current. A Monte Carlo simulation was performed by which the depopulation, disorientation and disalignment rates by the radiation re-absorption for these transitions were determined. The calculated rates were compared with the observed ones and found to reproduce the their discharge current dependences. D'Yankonov and Perel's analytical expression for these rates was quantified from comparison with the Monte Carlo results

  17. Lithium position and occupancy fluctuations in a cathode during charge/discharge cycling of lithium-ion battery

    International Nuclear Information System (INIS)

    Sharma, N.; Yu, D.; Zhu, Y.; Wu, Y.; Peterson, V. K.

    2012-01-01

    Lithium-ion batteries are undergoing rapid development to meet the energy demands of the transportation and renewable energy-generation sectors. The capacity of a lithium-ion battery is dependent on the amount of lithium that can be reversibly incorporated into the cathode. Neutron diffraction provides greater sensitivity towards lithium relative to other diffraction techniques. In conjunction with the penetration depth afforded by neutron diffraction, the information concerning lithium gained in a neutron diffraction study allows commercial lithium-ion batteries to be explored with respect to the lithium content in the whole cathode. Furthermore, neutron diffraction instruments featuring area detectors that allow relatively fast acquisitions enable perturbations of lithium location and occupancy in the cathode during charge/discharge cycling to be determined in real time. Here, we present the time, current, and temperature dependent lithium transfer occurring within a cathode functioning under conventional charge-discharge cycling. The lithium location and content, oxygen positional parameter, and lattice parameter of the Li 1+y Mn 2 0 4 cathode are measured and linked to the battery's charge/discharge characteristics (performance). We determine that the lithium-transfer mechanism involves two crystallographic sites, and that the mechanism differs between discharge and charge, explaining the relative ease of discharging (compared with charging) this material. Furthermore, we find that the rate of change of the lattice is faster on charging than discharging, and is dependent on the lithium insertion/ extraction processes (e.g. dependent on how the site occupancies evolve). Using in situ neutron diffraction data the atomic-scale understanding of cathode functionality is revealed, representing detailed information that can be used to direct improvements in battery performance at both the practical and fundamental level.

  18. Time-dependent simulation of plasma and electrodes in high-intensity discharge lamps with different electrode shapes

    CERN Document Server

    Flesch, P

    2003-01-01

    The subject of this paper is the modelling of d.c. and a.c. high-intensity Hg-discharge lamps with differently shaped electrodes. Different arc attachments on the electrodes are studied and insight for the development of new electrodes is gained. The model includes the entire discharge plasma (plasma column, hot plasma spots in front of electrodes, near-electrode non-LTE-plasma) as well as anode and cathode. No subdivision of the discharge space into different regions is necessary (like space charge layer, ionization zone, plasma column). This is achieved by using a differential equation for a non-LTE electrical conductivity which is applicable for local thermal equilibrium (LTE-)regions as well as for non-LTE plasma regions close to the electrodes in a high pressure plasma. Modelling results for a 0.6 MPa mercury discharge considering six different electrode shapes (anode and cathode) are presented and compared with experimental results. The electrodes have different diameters and different electrode tips, s...

  19. Seasonal Arsenic Accumulation in Stream Sediments at a Groundwater Discharge Zone

    DEFF Research Database (Denmark)

    MacKay, Allison A.; Gan, Ping; Yu, Ran

    2014-01-01

    Seasonal changes in arsenic and iron accumulation rates were examined in the sediments of a brook that receives groundwater discharges of arsenic and reduced iron. Clean glass bead columns were deployed in sediments for known periods over the annual hydrologic cycle to monitor changes in arsenic...... and iron concentrations in bead coatings. The highest accumulation rates occurred during the dry summer period (July-October) when groundwater discharges were likely greatest at the sample locations. The intermediate flow period (October-March), With higher surface water: levels, was associated with losses...... of arsenic and iron from bead column coatings at. depths below 2-6 cm. Batch incubations indicated iron releases from solids to be induced by biological reduction of iron (oxy)hydroxide solids. Congruent arsenic releases during incubation were limited by the high arsenic sorption capacity (0.536 mg...

  20. Study of transient phenomena in the Vivitron during an electric discharge

    International Nuclear Information System (INIS)

    Roumie, M.

    1994-04-01

    The Vivitron is a new Van der Graaff Tandem type accelerator, which is designed to reach 35 millions volts. The major problem which limits the voltage is the electrical discharge in insulating gas. This discharge leads to a spark short-circuiting two discrete electrodes, or column, and creates a transient developing a high electric field. Damage is observed on the column insulators. The aim of this work is to study the time evolution of the phenomena when the first spark is established. The use of computer simulations, with the PSpice code and physical models based on 'transmission lines' is first justified. Simulations of the real spark by a short-circuit are then carried out, using this model, to explain the progress of transients and to show the voltage modification. Several solutions for this problem are then proposed. (from author) 67 figs., 23 refs

  1. Assembly procedure for column cutting platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Column Cutting Platform and Elevation Support. The Column Cutting Platform is a component of the 241-SY-101 Equipment Removal System. It is set up on the deck of the Strongback Trailer to provide work access to cut off the upper portion of the Mitigation Pump Assembly (MPA). The Elevation Support provides support for the front of the Storage Container with the Strongback at an inclined position. The upper portion of the MPA must be cut off to install the Containment Caps on the Storage Container. The storage Container must be maintained in an inclined position until the Containment Caps are installed to prevent any residual liquids from migrating forward in the Storage Container

  2. Early discharge following birth

    DEFF Research Database (Denmark)

    Nilsson, Ingrid M. S.; Kronborg, Hanne; Knight, Christopher H.

    2017-01-01

    .26–0.48) and primiparous compared to multiparous had an OR of 0.22 (CI 0.17–0.29) for early discharge. Other predictors for early discharge were: no induction of labour, no epidural painkiller, bleeding less than 500 ml during delivery, higher gestational age, early expected discharge and positive breastfeeding experience...

  3. Development of a 130-mA, 75-kV high voltage column for high-intensity dc proton injectors

    International Nuclear Information System (INIS)

    Sherman, J.; Arvin, A.; Hansborough, L.; Hodgkins, D.; Meyer, E.; Schneider, J.D.; Stevens, R.R. Jr.; Zaugg, T.

    1997-01-01

    A reliable high-voltage (HV) column has been developed for dc proton injectors with applications to high-intensity cw linacs. The HV column is coupled with a microwave-driven plasma generator to produce a 75-keV, 110-mA dc proton beam. Typical proton fraction from this source is 85--90%, requiring the HV column and accelerating electrodes to operate with a 130-mA hydrogen-ion beam current. A glow-discharge, which was caused by the ion source axial magnetic field, was initially observed in the HV column. This problem was solved by scaling the electron production processes, the magnetic field, and the HV column pressure into a favorable regime. A subsequent 168 hour reliability run on the 75-keV injector showed that the ion source (plasma generator and HV column) has >98% beam availability

  4. Diffusion Processes in the Positive Column in a longitudinal magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Lehnert, B [Royal Institute of Technology, Stockholm (Sweden)

    1958-07-01

    The purpose of the present investigation is to study diffusion across a magnetic field in a configuration which is free from short-circuiting effects such as those described by Simon. It provides the possibility of deciding whether collision or 'drain' diffusion is operative. For the purpose a long cylindrical plasma column with a homogeneous magnetic field along the axis has been chosen. The theoretical treatment is given. On the basis of the collision diffusion theory Tonks, Rokhlin, Cummings and Tonks and Fataliev have pointed out that a longitudinal magnetic field will reduce the losses of particles to the walls. Consequently, when the magnetic field is present, a lower electron temperature and a smaller potential drop along the plasma column should be required to sustain a certain ion density. The present experiment forms an extension of that of Bickerton and von Engel into a range where the Schottky theory is applicable in the absence of a magnetic field and where the applied magnetic field is still made strong enough to influence the electron temperature.

  5. Two-photon absorption laser-induced fluorescence of atomic oxygen in the afterglow of pulsed positive corona discharge

    Science.gov (United States)

    Ono, Ryo; Takezawa, Kei; Oda, Tetsuji

    2009-08-01

    Atomic oxygen is measured in the afterglow of pulsed positive corona discharge using time-resolved two-photon absorption laser-induced fluorescence. The discharge occurs in a 14 mm point-to-plane gap in dry air. After the discharge pulse, the atomic oxygen density decreases at a rate of 5×104 s-1. Simultaneously, ozone density increases at almost the same rate, where the ozone density is measured using laser absorption method. This agreement between the increasing rate of atomic oxygen and decreasing rate of ozone proves that ozone is mainly produced by the well-known three-body reaction, O+O2+M→O3+M. No other process for ozone production such as O2(v)+O2→O3+O is observed. The spatial distribution of atomic oxygen density is in agreement with that of the secondary streamer luminous intensity. This agreement indicates that atomic oxygen is mainly produced in the secondary streamer channels, not in the primary streamer channels.

  6. The nature of the positive ion contribution to a gas discharge

    International Nuclear Information System (INIS)

    Fletcher, J.; Blevin, H.A.

    1980-06-01

    The technique for studying swarms of electrons in a gas discharge by observing the photon flux from the discharge developed in the authors's laboratories has been adapted to investigate the role of the secondary mechanisms in hydrogen and nitrogen. The results show that, contrary to previous indications, ion bombardment of the cathode plays only a negligible, if any, part in the low pressure discharge in hydrogen and nitrogen at low E/N while at high E/N only the contribution of the atomic ion is significant

  7. Analysis of the different zones of glow discharge of ethyl alcohol (C2H6O)

    International Nuclear Information System (INIS)

    Torres, C; Reyes, P G; Mulia, J; Castillo, F; Martínez, H

    2014-01-01

    The aim of this work is to explore the emission spectroscopy of ethyl alcohol in some regions, also is determine the result elements of the glow discharge, the spectrums were observed in a range of 200 at 1100 nm in the different zones inside of the tube at different distances of 20 and 30 cm. The elements are: in anode region C 6 H 5 (483.02 nm), CHO (519.56 nm) and H 2 (560.47 nm), in the positive column CO 2 + (315.52 y 337.00 nm), O + (357.48 nm), CH + (380.61 nm) and CO + (399.73 nm); in the cathode region we observed O + (391.19 nm), CHOCHO (428.00 nm), CO + (471.12 nm) and H 2 (656.52 nm). C 6 H 5 , CHO y H 2 species occurring in all regions analyzed varying the glow discharge emission intensity.

  8. Minimisation of noble gas discharge from 99Mo production at ANSTO

    International Nuclear Information System (INIS)

    Blagojevic, N.; Izard, M.

    2001-01-01

    Full text: Molybdenum-99 is one of the most important radionuclides in modem medicine. When loaded on a chromatographic column it forms a generator that produces high specific activity 99m Tc, a radionuclide widely used in nuclear medical imaging. ANSTO has been a main producer of 99 Mo in the Australasian region since the late 1960's and currently ranks as one of the major suppliers of 99m Tc/ 99 Mo generators. At ANSTO 99 Mo is produced from enriched uranium oxide (2.2% 235 U) after a nominal seven day irradiation period in HIFAR, Australia's high flux research reactor. Between four and six targets are processed, four to five times each week depending on the reactor operation timetable. After irradiation the targets are allowed to decay for approximately 6 hours before the uranium dioxide pellets are removed and dissolved in a fully enclosed heated vessel equipped with a reflux column. The dissolver off-gas containing noble gases and iodine isotopes released during this process are vented through a caustic scrubber, a number of iodine traps and finally through a charcoal based Noble Gas Trap (NGT). The uranium solution is passed through an alumina column to separate molybdenum from other elements. The 99 Mo product is eluted from the column with relatively concentrated ammonium hydroxide solution. The product recovery process consists of a volume reduction procedure followed by a recovery step designed to retrieve the product in a minimum volume of dilute nitric acid. The radioactive Xe and Kr discharge was monitored using a Nal(TI) detector based gamma-ray spectrometer system that was interfaced to the internal computer network. The data was collected and sent to the network server at 15-minute intervals using locally written programs that process and database the information. The discharge data is displayed in real time by the use of web browsers found on all networked workstations. The network program is also capable of interrogating the database so that the

  9. Modeling Stone Columns.

    Science.gov (United States)

    Castro, Jorge

    2017-07-11

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  10. Radio-frequency wave excitation and damping on a high β plasma column

    International Nuclear Information System (INIS)

    Meuth, H.

    1984-01-01

    Azimuthally symmetric (m = 0) radio-frequency (RF) waves for zero and for finite axial wave number k/sub z/ are investigated on the High BETA Q Machine, a two-meter, 20 cm-diameter, low-compression linear theta pinch (T greater than or equal to 200 eV, n approx. = 10 15 cm -3 ) fast rising (0.4 μs) compression field. The (k/sub z/ = 0) modes occur spontaneously following the implosion phase of the discharge. A novel 100-MW 1 to 1.3 MHz, short wavelength current drive excites the plasma column in the vicinity of the lowest fast magnetoacoustic mode at various filling pressures. This current drive is designed as an integral part of the compression coil, which is segmented with a 20-cm axial wavelength (k/sub z/ = 0.314 cm -1 ). The electron density oscillations along major and minor chords at various positions are measured by interferometry perpendicular to the pinch axis. The oscillatory radial magnetic field component between pinch wall and hot plasma edge is measured by probes. Phases, amplitudes and radial mode structure are studied for the free (k = 0) modes and the externally driven (k does not equal 0) modes for various filling pressures of deuterium. The energy deposition from the externally driven RF wave leads to a radial expansion of the plasma column, as observed by axial interferometry and by excluded flux measurements

  11. Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns?

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Dennis, Gary R; Shalliker, R Andrew

    2015-08-19

    Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 μm particles. The data showed that reaction loops beyond 100 μL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column. Copyright © 2015. Published by Elsevier B.V.

  12. Characteristics of an elongated plasma column produced by magnetically coupled hollow cathode plasma source

    Science.gov (United States)

    Bhuva, M. P.; Karkari, S. K.; Kumar, Sunil

    2018-03-01

    An elongated plasma column in the presence of an axial magnetic field has been formed using a cylindrical hollow cathode (HC) and a constricted anode (CA). The plasma characteristics of the central line have been found to vary with the magnetic field strength and the axial distance from the source. It is believed that the primary electrons constituting the discharge current are steered by the axial magnetic field to undertake ionizing collisions along the plasma column. The current carrying electrons from the HC reach the anode by cross-field diffusion towards the central line. The above observation has been substantiated using a phenomenological model which links the observed characteristics of the source with the plasma column. The experimental results are found to be in qualitative agreement with the model.

  13. Electron beam generation in z-pinch discharges

    Energy Technology Data Exchange (ETDEWEB)

    Vikhrev, V.V.; Baronova, E.O. [Kurchatov Inst., Moscow (Russian Federation). Russian Research Center

    1997-12-31

    Numerical modelling of the process of electron beam generation in z-pinch discharges are presented. The proposed model represents the electron beam generation under turbulent plasma conditions. Strong current distribution inhomogeneity in the plasma column and the zigzag drift current motion through the plasma have accounted for the adequate generation process investigation. Electron beam is generated near the maximum of compression and it is not related with the current break effect. (author)

  14. Estimating contaminant discharge rates from stabilized uranium tailings embankments

    International Nuclear Information System (INIS)

    Weber, M.F.

    1986-01-01

    Estimates of contaminant discharge rates from stabilized uranium tailings embankments are essential in evaluating long-term impacts of tailings disposal on groundwater resources. Contaminant discharge rates are a function of water flux through tailings covers, the mass and distribution of tailings, and the concentrations of contaminants in percolating pore fluids. Simple calculations, laboratory and field testing, and analytical and numerical modeling may be used to estimate water flux through variably-saturated tailings under steady-state conditions, which develop after consolidation and dewatering have essentially ceased. Contaminant concentrations in water discharging from the tailings depend on tailings composition, leachability and solubility of contaminants, geochemical conditions within the embankment, tailings-water interactions, and flux of water through the embankment. These concentrations may be estimated based on maximum reported concentrations, pore water concentrations, extrapolations of column leaching data, or geochemical equilibria and reaction pathway modeling. Attempts to estimate contaminant discharge rates should begin with simple, conservative calculations and progress to more-complicated approaches, as necessary

  15. Use of ultrasonic array method for positioning multiple partial discharge sources in transformer oil.

    Science.gov (United States)

    Xie, Qing; Tao, Junhan; Wang, Yongqiang; Geng, Jianghai; Cheng, Shuyi; Lü, Fangcheng

    2014-08-01

    Fast and accurate positioning of partial discharge (PD) sources in transformer oil is very important for the safe, stable operation of power systems because it allows timely elimination of insulation faults. There is usually more than one PD source once an insulation fault occurs in the transformer oil. This study, which has both theoretical and practical significance, proposes a method of identifying multiple PD sources in the transformer oil. The method combines the two-sided correlation transformation algorithm in the broadband signal focusing and the modified Gerschgorin disk estimator. The method of classification of multiple signals is used to determine the directions of arrival of signals from multiple PD sources. The ultrasonic array positioning method is based on the multi-platform direction finding and the global optimization searching. Both the 4 × 4 square planar ultrasonic sensor array and the ultrasonic array detection platform are built to test the method of identifying and positioning multiple PD sources. The obtained results verify the validity and the engineering practicability of this method.

  16. Singlet oxygen generation in a high pressure non-self-sustained electric discharge

    International Nuclear Information System (INIS)

    Hicks, Adam; Norberg, Seth; Shawcross, Paul; Lempert, Walter R; Rich, J William; Adamovich, Igor V

    2005-01-01

    This paper presents results of singlet oxygen generation experiments in a high-pressure, non-self-sustained crossed discharge. The discharge consists of a high-voltage, short pulse duration, high repetition rate pulsed discharge, which produces ionization in the flow, and a low-voltage dc discharge which sustains current in a decaying plasma between the pulses. The sustainer voltage can be independently varied to maximize the energy input into electron impact excitation of singlet delta oxygen (SDO). The results demonstrate operation of a stable and diffuse crossed discharge in O 2 -He mixtures at static pressures of at least up to P 0 = 380 Torr and sustainer discharge powers of at least up to 1200 W, achieved at P 0 = 120 Torr. The reduced electric field in the positive column of the sustainer discharge varies from E/N = 0.3 x 10 -16 to 0.65 X 10 -16 V cm 2 , which is significantly lower than E/N in self-sustained discharges and close to the theoretically predicted optimum value for O 2 (a 1 Δ) excitation. Measurements of visible emission spectra O 2 (b 1 Σ → X 3 Σ) in the discharge afterglow show the O 2 (b 1 Σ) concentration to increase with the sustainer discharge power and to decrease as the O 2 fraction in the flow is increased. Rotational temperatures inferred from these spectra in 10% O 2 -90% He flows at P 0 = 120 Torr and mass flow rates of m-dot = 2.2 are 365-465 K. SDO yield at these conditions, 1.7% to 4.4%, was inferred from the integrated intensity of the (0, 0) band of the O 2 (a 1 Δ → X 3 Σ) infrared emission spectra calibrated using a blackbody source. The yield remains nearly constant in the discharge afterglow, up to at least 15 cm distance from the discharge. Kinetic modelling calculations using a quasi-one-dimensional nonequilibrium pulser-sustainer discharge model coupled with the Boltzmann equation for plasma electrons predict gas temperature rise in the discharge in satisfactory agreement with the experimental measurements

  17. Assembly for connecting the column ends of two capillary columns

    International Nuclear Information System (INIS)

    Kolb, B.; Auer, M.; Pospisil, P.

    1984-01-01

    In gas chromatography, the column ends of two capillary columns are inserted into a straight capillary from both sides forming annular gaps. The capillary is located in a tee out of which the capillary columns are sealingly guided, and to which carrier gas is supplied by means of a flushing flow conduit. A ''straight-forward operation'' having capillary columns connected in series and a ''flush-back operation'' are possible. The dead volume between the capillary columns can be kept small

  18. Free double layers in mercury-arc discharges

    International Nuclear Information System (INIS)

    Maciel, H.S.; Allen, J.E.

    1989-01-01

    A study has been carried out of free double layers formed within the plasma volume of a low-pressure mercury-arc discharge at high current densities. The free double layer is observed to form as a visible boundary, which drifts slowly from the central section of the discharge. Current-driven instabilities are observed as the discharge current is gradually increased to a critical value, at which current limitation is observed to occur. This process, which is accompanied by high-current spikes, ceases when the free double layer becomes visible as a sharp boundary dividing the discharge column into two regions of different luminosities. The layer is observed to form in the later stages of current limitation, the onset of which occurs for a ratio of drift to thermal speed of electrons of about unity. Electrical energy is converted by the layer into kinetic energy of the changed particles. Accordingly high-energy ions were measured by means of an electrostatic energy analyser. The multiple-sheath character of the free 'double layer'', which is inferred from probe measurements of potential profiles, is discussed and comparisons with other space-charge structures with the same topology are made. (author)

  19. Formation of H- ions via vibrational excited molecules produced from recombinative wall desorption of H atoms in a low-pressure H/sub 2/ positive column

    NARCIS (Netherlands)

    Amorim, J.; Loureiro, J.; Schram, D.C.

    2001-01-01

    Recombinative wall desorption of hydrogen atoms in a low-pressure hydrogen positive column leading to formation of H/sub 2/ (X/sup 1/ Sigma /sub g//sup +/, v) molecules in optimum levels for H/sup -/ production by dissociative attachment is investigated. We employed a kinetic model that solves the

  20. Isotopes accumulation in the thermal column of TRIGA reactor

    International Nuclear Information System (INIS)

    Iorgulis, C.; Diaconu, D.; Gugiu, D.; Csaba, R.

    2013-01-01

    The correlation of impurity observed in the virgin graphite and radionuclide content and activities measured in the irradiated graphite needs to know the irradiated history. This is a challenging process if impurity content and irradiation conditions are not accurately known. This is the case of the irradiated graphite in the thermal column of Institute for Nuclear Research Pitesti (INR)14 MW TRIGA reactor. To overcome incomplete impurity content and the unknown position in the column of the measured irradiated graphite available for characterisation and comparison, a set of preliminary simulations were performed. Following Eu 152 /Eu 154 ration they allowed the estimation of an impurity content and irradiation conditions leading to measured activities. Based on these data the radio-isotope accumulation in different positions in the thermal column was predicted. Modelling performed by INR used advanced prediction packages (e.g. WIMS, MCNP ORIGEN-S from Scale 5) to assess the isotopic content of MTR graphite types with irradiation history specific for a TRIGA research reactor. Some certain calculations points from the column were selected in order to model the burnup and isotopes productions using ORIGEN from SCALE code system. (authors)

  1. Study of the excitation mechanisms of the second positive system in the negative glow of a N2-Ar discharge

    International Nuclear Information System (INIS)

    Isola, L; Lopez, M; Gomez, B J

    2011-01-01

    In an Ar-N 2 discharge, the high excitation transfer from Ar( 3 P 2,0 ) to N 2 produces an overpopulation of the high rotational levels of the bands of the second positive system (SPS), and so the spectra interpretation is not straightforward. This paper presents a fit function for the SPS bands measured in Ar-N 2 , which allows us to study the excitation process contributions to the N 2 (C) level. The procedure was tested in the negative glow of a pulsed Ar-N 2 discharge at a pressure of 2.5 Torr, for different mixture concentrations. In this discharge, through the fitting, it was possible to calculate the variation of the N 2 (C) densities produced by different excitation processes as well as the variation of Ar metastable density.

  2. Second dimension column ensemble pressure tuning in comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Junior, Ademario I da Silva; Marriott, Philip J

    2018-02-09

    A pressure tunable (PT) coupled column ensemble has been implemented for the second dimension ( 2 D) separation in comprehensive two dimensional gas chromatography (GC×PTGC). This process requires two columns to be connected by a pressure junction, as a replacement for a single narrow bore, short column in 2 D. Various 2 D 1 and 2 D 2 columns may be selected to provide complementary selectivity (polarity) compared to the 1 D column. The tunable residence time arising from differential pressure drop in each 2 D column results in a tunable fractional contribution of each column in the 2 D separation. A sample mixture comprising different chemical classes, including alkanes and alcohols, is used to identify the feasibility and extent of selectivity tuning possible in GC×PTGC. The column length is also varied due to the imposed challenge of wraparound in the PT coupled column system as pressures are adjusted in the 2 D separation. Different experimental parameters, stationary phase materials and column lengths have been applied to investigate and understand the separation behaviour of the 2 D PT coupled column GC×GC system. Results are discussed considering analyte retention time, peak width, linear velocity and the contribution of each 2 D column. A specific and unexpected example of GC×GC separation was demonstrated where the peak positions of polar and apolar compounds could almost swap their 2 D retention position by application of PT. Kerosene was analysed as an example of complex sample analysis by GC×PTGC system. This process is shown to be a practical approach for altering different stationary phase selectivities in a single 2 D arrangement in GC×GC. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Magnetic field effects on electrical parameters of rf excited CO{sub 2} lasers

    Energy Technology Data Exchange (ETDEWEB)

    Tavassoli, S.H. [Laser Research Institute and Physics Department of Shahid Beheshti University, Evin, Tehran (Iran, Islamic Republic of)]. E-mail: h-tavassoli@cc.sbu.ac.ir; Latifi, H. [Laser Research Institute and Physics Department of Shahid Beheshti University, Evin, Tehran (Iran, Islamic Republic of)

    2005-02-14

    In the present Letter a rf excited CO{sub 2} laser embedded in an external, constant, and homogeneous magnetic field is considered. The magnetic field effects on some discharge parameters such as V-I characteristics, impedance of sheaths and positive column of plasma, intensity of visible emission from plasma and thickness of positive column are investigated. There is an increase in thickness of positive column and output power in presence of magnetic field. Magnetic field leads to an increase in the discharge voltage and impedance for lower current densities and a decrease for higher ones. There is a current density in which the magnetic field has no effects on discharge voltage and impedance. There are two peaks on intensity of visible emission from the discharge which at higher magnetic field are pushed out toward the electrodes.

  4. RELATIONSHIP BETWEEN THE USE OF KANGAROO POSITION ON PRETERM BABIES AND MOTHER-CHILD INTERACTION UPON DISCHARGE

    OpenAIRE

    Nunes, Cynthia Ribeiro do Nascimento; Campos, Lu?s Gustavo; Lucena, Aline Moreira; Pereira, Janser Moura; da Costa, Patr?cia Rodrigues; de Lima, Fl?via Aparecida Felipe; Azevedo, Vivian Mara Gon?alves de Oliveira

    2017-01-01

    ABSTRACT Objective: To analyze the influence of the Kangaroo Position duration in the initial interactions between mothers and preterm infants. Methods: This is an exploratory prospective observational study that analyzed the mother-infant interaction during breastfeeding, before hospital discharge. All eligible newborns, with a gestational age of 28-32 weeks and a birth weight of 1,000-1,800 g from June 11 to September 31, 2014 were included. The films of the interaction were evaluated by th...

  5. Study of plasma discharge evolution and edge turbulence with fast visible imaging in the Aditya tokamak

    International Nuclear Information System (INIS)

    Banerjee, Santanu; Manchanda, R.; Chowdhuri, M.B.

    2015-01-01

    Study of discharge evolution through the different phases of a tokamak plasma shot viz., the discharge initiation, current ramp-up, current flat-top and discharge termination, is essential to address many inherent issues of the operation of a Tokamak. Fast visible imaging of the tokamak plasma can provide valuable insight in this regard. Further, edge turbulence is considered to be one of the quintessential areas of tokamak research as the edge plasma is at the immediate vicinity of the plasma core and plays vital role in the core plasma confinement. The edge plasma also bridges the core and the scrape off layer (SOL) of the tokamak and hence has a bearing on the particle and heat flux escaping the plasma column. Two fast visible imaging systems are installed on the Aditya tokamak. One of the system is for imaging the plasma evolution with a wide angle lens covering a major portion of the vacuum vessel. The imaging fiber bundle along with the objective lens is installed inside a radial re-entrant viewport, specially designed for the purpose. Another system is intended for tangential imaging of the plasma column. Formation of the plasma column and its evolution are studied with the fast visible imaging in Aditya. Features of the ECRH and LHCD operations on Aditya will be discussed. 3D filaments can, be seen at the plasma edge all along the discharge and they get amplified in intensity at the plasma termination phase. Statistical analysis of these filaments, which are essentially plasma blobs will be presented. (author)

  6. Water column conditions in a coastal lagoon near Jeddah, Red Sea

    Directory of Open Access Journals (Sweden)

    Alaa M. A. Albarakati

    2012-11-01

    Full Text Available Water column conditions in a lagoon near Jeddah are investigated on the basisof changes in potential energy. Three major factors including balance ofsurface heat at the air-sea interface, wind and tidal mixing are considered.A negative potential energy change dv/dt will developstratification, whereas positive dv/dt will tend to mix the watercolumn. The tidal effect is greater in summer with wind mixing showing nogreat variations. The buoyancy effect of the heat balance at the surface isnegative from April to October. This negative buoyancy effect will tend to developstratification but the positive contributions of wind and tide counteract this andthe water column remains mixed except in September and October, when a weakstratification may develop. Generally, the water column remains practically mixedthroughout the year. The change in heat content of the water column from mid-Aprilto mid-September is about 3.3 × 108 J. During this period the netheat input at the air interface is about 2.0 × 108 J, which isabout 40% less than the heat content of the water column, showing that the heat is advected towards the central area from the shallower periphery of the lagoon.

  7. Optimal design of zero-water discharge rinsing systems.

    Science.gov (United States)

    Thöming, Jorg

    2002-03-01

    This paper is about zero liquid discharge in processes that use water for rinsing. Emphasis was given to those systems that contaminate process water with valuable process liquor and compounds. The approach involved the synthesis of optimal rinsing and recycling networks (RRN) that had a priori excluded water discharge. The total annualized costs of the RRN were minimized by the use of a mixed-integer nonlinear program (MINLP). This MINLP was based on a hyperstructure of the RRN and contained eight counterflow rinsing stages and three regenerator units: electrodialysis, reverse osmosis, and ion exchange columns. A "large-scale nickel plating process" case study showed that by means of zero-water discharge and optimized rinsing the total waste could be reduced by 90.4% at a revenue of $448,000/yr. Furthermore, with the optimized RRN, the rinsing performance can be improved significantly at a low-cost increase. In all the cases, the amount of valuable compounds reclaimed was above 99%.

  8. New spectroscopic observations in electric discharges through carbon monoxide

    Science.gov (United States)

    Cossart, Daniel

    2002-02-01

    Two types of electric discharges were used: (a) In a supersonic expansion of pure CO gas. (b) In a U-shaped tube immersed in liquid nitrogen where either pure CO or mixtures of CO+He, CO+Ne, CO+NO are introduced. In both cases, the analyzed emissions were exclusively those issuing from the negative glows of the discharges. Fourier Transform spectra were recorded in the 28 000-17 000 cm-1 visible spectral region and also in the 8000-2000 cm-1 infra-red interval. Comparison of the two sets of spectra showed that spectra (a) correspond to excitation of the primary species whereas spectra (b) result from excitation of final compounds produced in the positive column. In the latter case, the main new observations are: (i) Selective excitation of particular upper state vibrational levels in the E 3Σ--a 3Π Herman system. (ii) Appearance of the C1Σ +- B1Σ + (0,0) Rydberg-Rydberg infrared band whereas the associated optical C1Σ +- A1Π Herzberg transition is absent. (iii) "Anomalous" vibrational distribution in the ground state vibration-rotation spectra. All the above observations are concomitant with previously reported IR emissions involving very high rotational levels (up to J=120) in the ground state. To explain them, processes involving dissociative recombinations of dimer cations are suggested.

  9. Contributions to reversed-phase column selectivity: III. Column hydrogen-bond basicity.

    Science.gov (United States)

    Carr, P W; Dolan, J W; Dorsey, J G; Snyder, L R; Kirkland, J J

    2015-05-22

    Column selectivity in reversed-phase chromatography (RPC) can be described in terms of the hydrophobic-subtraction model, which recognizes five solute-column interactions that together determine solute retention and column selectivity: hydrophobic, steric, hydrogen bonding of an acceptor solute (i.e., a hydrogen-bond base) by a stationary-phase donor group (i.e., a silanol), hydrogen bonding of a donor solute (e.g., a carboxylic acid) by a stationary-phase acceptor group, and ionic. Of these five interactions, hydrogen bonding between donor solutes (acids) and stationary-phase acceptor groups is the least well understood; the present study aims at resolving this uncertainty, so far as possible. Previous work suggests that there are three distinct stationary-phase sites for hydrogen-bond interaction with carboxylic acids, which we will refer to as column basicity I, II, and III. All RPC columns exhibit a selective retention of carboxylic acids (column basicity I) in varying degree. This now appears to involve an interaction of the solute with a pair of vicinal silanols in the stationary phase. For some type-A columns, an additional basic site (column basicity II) is similar to that for column basicity I in primarily affecting the retention of carboxylic acids. The latter site appears to be associated with metal contamination of the silica. Finally, for embedded-polar-group (EPG) columns, the polar group can serve as a proton acceptor (column basicity III) for acids, phenols, and other donor solutes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  11. Thermal neutron flux distribution in ET-RR-2 reactor thermal column

    Directory of Open Access Journals (Sweden)

    Imam Mahmoud M.

    2002-01-01

    Full Text Available The thermal column in the ET-RR-2 reactor is intended to promote a thermal neutron field of high intensity and purity to be used for following tasks: (a to provide a thermal neutron flux in the neutron transmutation silicon doping, (b to provide a thermal flux in the neutron activation analysis position, and (c to provide a thermal neutron flux of high intensity to the head of one of the beam tubes leading to the room specified for boron thermal neutron capture therapy. It was, therefore, necessary to determine the thermal neutron flux at above mentioned positions. In the present work, the neutron flux in the ET-RR-2 reactor system was calculated by applying the three dimensional diffusion depletion code TRITON. According to these calculations, the reactor system is composed of the core, surrounding external irradiation grid, beryllium block, thermal column and the water reflector in the reactor tank next to the tank wall. As a result of these calculations, the thermal neutron fluxes within the thermal column and at irradiation positions within the thermal column were obtained. Apart from this, the burn up results for the start up core calculated according to the TRITION code were compared with those given by the reactor designer.

  12. Operation of the annular pulsed column, (2)

    International Nuclear Information System (INIS)

    Takahashi, Keiki; Tsukada, Takeshi

    1988-01-01

    The heat of reaction generated form the uranium extraction is considered to from the temperature profile inside the pulsed column. A simulation code was developed to estimate the temperature profile, considering heat generation and counter-current heat transfer. The temperature profiles calculated using this code was found to depend on both the position of the extraction zone and the operating condition. The reported experimental result was fairly represented by this simulation code. We consider that this presented simulation code is capable of providing with the temperature profile in the pulsed column and useful for the monitoring of the uranium extraction zone. (author)

  13. Rapid temperature increase near the anode and cathode in the afterglow of a pulsed positive streamer discharge

    Science.gov (United States)

    Ono, Ryo

    2018-06-01

    The spatiotemporal evolution of the temperature in the afterglow of point-to-plane, pulsed positive streamer discharge was measured near the anode tip and cathode surface using laser-induced predissociation fluorescence of OH radicals. The temperature exhibited a rapid increase and displayed a steep spatial gradient after a discharge pulse. The rate of temperature rise reached 84 K μs‑1 at mm, where z represents the distance from the anode tip. The temperature rise was much faster than in the middle of the gap; it was only 2.8 K μs‑1 at mm. The temperature reached 1700 K near the anode tip at s and 1500 K near the cathode surface at s, where t represents the postdischarge time. The spatial gradient reached 1280 K mm‑1 near the anode tip at s. The mechanism responsible for the rapid temperature increase was discussed, including rapid heating of the gas in the early postdischarge phase (s), and vibration-to-translation energy transfer in the later postdischarge phase (s). The high temperatures near the anode tip and cathode surface are particularly important for the ignition of combustible mixtures and for surface treatments, including solid-surface treatments, water treatments, and plasma medicine using pulsed streamer discharges.

  14. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  15. Co-infections with Ureaplasma parvum, Mycoplasma hominis and Chlamydia trachomatis in a human immunodeficiency virus positive woman with vaginal discharge.

    Science.gov (United States)

    Ghosh, Arnab; Rawre, Jyoti; Khanna, Neena; Dhawan, Benu

    2013-01-01

    A 30-year-old human immunodeficiency virus (HIV)-1 infected woman presented with vaginal discharge and associated vulval irritation. The vaginal swabs tested positive for Ureaplasma parvum and Mycoplasma hominis by both culture and polymerase chain reaction (PCR). The specimen also tested positive for Chlamydia trachomatis deoxyribonucleic acid (DNA) by cryptic plasmid and omp1 gene PCR assays. The patient was successfully treated with azithromycin based on the antibiotic susceptibility testing results of U. parvum and M. hominis by microbroth dilution. Since sexually transmitted infections enhance the transmission of HIV, HIV-positive patients should be screened routinely for these pathogens.

  16. Study of the excitation mechanisms of the second positive system in the negative glow of a N{sub 2}-Ar discharge

    Energy Technology Data Exchange (ETDEWEB)

    Isola, L; Lopez, M; Gomez, B J, E-mail: isola@ifir-conicet.gov.ar [Instituto de Fisica Rosario (CONICET-UNR) 27 Febrero 210 Bis. (S2000EZP) Rosario (Argentina)

    2011-09-21

    In an Ar-N{sub 2} discharge, the high excitation transfer from Ar({sup 3}P{sub 2,0}) to N{sub 2} produces an overpopulation of the high rotational levels of the bands of the second positive system (SPS), and so the spectra interpretation is not straightforward. This paper presents a fit function for the SPS bands measured in Ar-N{sub 2}, which allows us to study the excitation process contributions to the N{sub 2}(C) level. The procedure was tested in the negative glow of a pulsed Ar-N{sub 2} discharge at a pressure of 2.5 Torr, for different mixture concentrations. In this discharge, through the fitting, it was possible to calculate the variation of the N{sub 2}(C) densities produced by different excitation processes as well as the variation of Ar metastable density.

  17. Current and potential distributions on positive plates with conductive Pb{sub 3}O{sub 4} and BaPbO{sub 3} in their formation and discharge

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yonglang; Liu, Huan [College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou 350108 (China)

    2008-08-15

    The positive plates with conductive materials, Pb{sub 3}O{sub 4} and BaPbO{sub 3}, in automotive lead-acid batteries were investigated by measuring their current and potential distributions in the course of formation and discharge. It is found that these two conductive materials, especially Pb{sub 3}O{sub 4}, enhance the formation in the initial stage greatly and that they make the current and potential distributions more uniform. In the discharge, the addition of Pb{sub 3}O{sub 4} increases the capacity of the positive plate, but it is unfavorable to the paste curing and causes poor contact between active mass (AM) particles so that the polarization increases greatly at 3 C discharge rate. The BaPbO{sub 3} additive improves not only the formation but also the discharge performance because of its stability in acidic media and at high polarization. The violent charge at high polarization around the plates in the initial formation can lead to poor AM contact and high polarization resistance. (author)

  18. Modeling North Sea oil-based mud cuttings discharges to assess environmental loading: An E ampersand P forum study

    International Nuclear Information System (INIS)

    Brandsma, M.G.; McKelvie, S.

    1994-01-01

    Oil concentrations in the water column and benthic sediments caused by the discharge of oily cuttings were predicted at four North Sea sites using a computer model. The cuttings were drilled with oil based mud and were treated to reduce oil content prior to discharge. The predictions allowed the results of biological experiments to be related to field conditions in a multi-disciplinary research project. The goal of the project was to determine what amount of oil remaining on the cuttings is environmentally acceptable. Model results suggested that treatment reduced maximum and average oil concentrations in benthic sediments by more than 93%. Frequently, the maximum concentration was reduced below the 1,000 ppm identified in the biological experiments as the sediment oil concentration above which significant effects on biological communities may be observed. Reductions of oil concentrations in the cuttings were accompanied by reduced particle sizes and settling velocities. This resulted in increased dispersion at the seabed and caused water column oil concentrations to increase. The increased water column concentrations were still several orders of magnitude below toxic levels

  19. Electric field strength in a silicon surface barrier detector with the presence of a dielectric plasma column

    International Nuclear Information System (INIS)

    Kanno, Ikuo

    1994-01-01

    The dynamic change of the electric field strength in a silicon surface barrier detector (SSBD) is studied. With the presence of a dielectric plasma column in the depletion layer of the SSBD, the electric field strength inside/outside the plasma column is suppressed/enhanced. As the length and the dielectric constant of the plasma column become shorter and smaller, the suppression and enhancement of the electric field strength become less. The electric field strength recovers the initial state, when the plasma column disappears. When the electrons and holes are inside/outside the dielectric plasma column, they have less/more electric potential than the one they have when there is no plasma column. During the movement of the electron/hole outside the plasma column to the positive/negative electrode, the enhanced electric field strength becomes smaller. Electron and hole pairs, which are the parts of the dielectric plasma column, arrive at positive and negative electrodes, having insufficient electric potential to induce the unit charge. This paper shows that the presence of a dielectric plasma column explains the main part of the residual defect in a SSBD. ((orig.))

  20. Investigation of airflow effects on the dielectric barrier discharge with single/double discharge channel arrangement

    Science.gov (United States)

    Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng

    2018-05-01

    Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.

  1. Optical and electrostatic potential investigations of electrical breakdown phenomena in a low-pressure gas discharge lamp

    International Nuclear Information System (INIS)

    Gendre, M F; Haverlag, M; Kroesen, G M W

    2010-01-01

    The ignition phase is a critical stage in the operation of gas discharge lamps where the neutral gas enclosed between the electrodes undergoes a transformation from the dielectric state to a conducting phase, eventually enabling the production of light. The phenomena occurring during this phase transition are not fully understood and the related experimental studies are often limited to local optical measurements in environments prone to influencing these transient phenomena. In this work unipolar ignition phenomena at sub-kilovolt levels are investigated in a 3 Torr argon discharge tube. The lamp is placed in a highly controlled environment so as to prevent any bias on the measurements. A fast intensified CCD camera and a specially designed novel electrostatic probe are used simultaneously so as to provide a broad array of measured and computed parameters which are displayed in space-time diagrams for cross comparisons. Experiments show that three distinct phases exist during successful ignitions: upon the application of voltage a first ionization wave starts from the active electrode and propagates in the neutral gas towards the opposite electrode. A local front of high axial E field strength is associated with this process and causes a local ionization to occur, leading to the electrostatic charging of the lamp. Next, a second wave propagates from the ground electrode back towards the active electrode with a higher velocity, and in this process leads to a partial discharging of the lamp. This return stroke draws a homogeneous plasma column which eventually bridges both electrodes at the end of the wave propagation. At this point both electrode sheaths are formed and the common features of a glow discharge are observed. The third phase is an increase in the light intensity of the plasma column until the lamp reaches a steady-state operation. Failed ignitions present only the first phase where the first wave starts its propagation but extinguishes in the lamp

  2. Dynamic Characteristics of Positive Pulsed Dielectric Barrier Discharge for Ozone Generation in Air

    International Nuclear Information System (INIS)

    Wei Linsheng; Peng Bangfa; Li Ming; Zhang Yafang; Hu Zhaoji

    2016-01-01

    A comprehensive dynamic model consisting of 66 reactions and 24 species is developed to investigate the dynamic characteristics of ozone generation by positive pulsed dielectric barrier discharge (DBD) using parallel-plate reactor in air. The electron energy conservation equation is coupled to the electron continuity equation, the heavy species continuity equation, and Poisson's equation for a better description. The reliability of the model is experimentally confirmed. The model can be used to predict the temporal and spatial evolution of species, as well as streamer propagation. The simulation results show that electron density increases nearly exponentially in the direction to the anode at the electron avalanche. Streamer propagation velocity is about 5.26 × 10 4 m/s from anode to cathode in the simulated condition. The primary positive ion, negative ion, and excited species are O 2 + , O 3 − and O 2 ( 1 Δg) in pulsed DBD in air, respectively. N 2 O has the largest density among nitrogen oxides. e and N 2 + densities in the streamer head increase gradually to maximum values with the development of the streamer. Meanwhile, the O 2 + , O, O 3 , N 2 (A 3 Σ) and N 2 O densities reach maximum values in the vicinity of the anode. (paper)

  3. Towards Reconstructing a Doric Column in a Virtual Construction Site

    Science.gov (United States)

    Bartzis, D.

    2017-02-01

    This paper deals with the 3D reconstruction of ancient Greek architectural members, especially with the element of the Doric column. The case study for this project is the Choragic monument of Nicias on the South Slope of the Athenian Acropolis, from which a column drum, two capitals and smaller fragments are preserved. The first goal of this paper is to present some benefits of using 3D reconstruction methods not only in documentation but also in understanding of ancient Greek architectural members. The second goal is to take advantage of the produced point clouds. By using the Cloud Compare software, comparisons are made between the actual architectural members and an "ideal" point cloud of the whole column in its original form. Seeking for probable overlaps between the two point clouds could assist in estimating the original position of each member/fragment on the column. This method is expanded with more comparisons between the reference column model and other members/fragments around the Acropolis, which may have not yet been ascribed to the monument of Nicias.

  4. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator

    International Nuclear Information System (INIS)

    Nolot, E.

    1996-01-01

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF 6 . This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF 6 . In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author)

  5. Sol-gel open tubular ODS columns with reversed electroosmotic flow for capillary electrochromatography.

    Science.gov (United States)

    Hayes, J D; Malik, A

    2001-03-01

    Sol-gel chemistry was successfully used for the fabrication of open tubular columns with surface-bonded octadecylsilane (ODS) stationary-phase coating for capillary electrochromatography (OT-CEC). Following column preparations, a series of experiments were performed to investigate the performance of the sol-gel coated ODS columns in OT-CEC. The incorporation of N-octadecyldimethyl[3-(trimethoxysilyl)propyl]ammonium chloride as one of the sol-gel precursors played an important role in the electrochromatographic performance of the prepared columns. This chemical reagent possesses a chromatographically favorable, bonded ODS moiety, in conjunction with three methoxy groups allowing for sol-gel reactivity. In addition, a positively charged nitrogen atom is present in the molecular structure of this reagent and provides a positively charged capillary surface responsible for the reversed electroosmotic flow (EOF) in the columns during CEC operation. Comparative studies involving the EOF within such sol-gel ODS coated and uncoated capillaries were performed using acetonitrile and methanol as the organic modifiers in the mobile phase. The use of a deactivating reagent, phenyldimethylsilane, in the sol-gel solution was evaluated. Efficiency values of over 400,000 theoretical plates per meter were achieved in CEC on a 64 cm x 25 microm i.d. sol-gel ODS open tubular column. Test mixtures of polycyclic aromatic hydrocarbons, benzene derivatives, and aromatic aldehydes and ketones were used to evaluate the CEC performances of both nondeactivated and deactivated open tubular sol-gel columns. The effects of mobile-phase organic modifier contents and pH on EOF in such columns were evaluated. The prepared sol-gel ODS columns are characterized by switchable electroosmotic flow. A pH value of approximately 8.5 was found correspond to the isoelectric point for the prepared sol-gel ODS coatings.

  6. Preliminary study on the modelling of negative leader discharges

    International Nuclear Information System (INIS)

    Arevalo, L; Cooray, V

    2011-01-01

    Nowadays, there is considerable interest in understanding the physics underlying positive and negative discharges because of the importance of improving lightning protection systems and of coordinating the insulation for high voltages. Numerical simulations of positive switching impulses made in long spark gaps in a laboratory are achievable because the physics of the process is reasonably well understood and because of the availability of powerful computational methods. However, the existing work on the simulation of negative switching discharges has been held up by a lack of experimental data and the absence of a full understanding of the physics involved. In the scientific community, it is well known that most of the lightning discharges that occur in nature are of negative polarity, and because of their complexity, the only way to understand them is to generate the discharges in laboratories under controlled conditions. The voltage impulse waveshape used in laboratories is a negative switching impulse. With the aim of applying the available information to a self-consistent physical method, an electrostatic approximation of the negative leader discharge process is presented here. The simulation procedure takes into consideration the physics of positive and negative discharges, considering that the negative leader propagates towards a grounded electrode and the positive leader towards a rod electrode. The simulation considers the leader channel to be thermodynamic, and assumes that the conditions required to generate a thermal channel are the same for positive and negative leaders. However, the magnitude of the electrical charge necessary to reproduce their propagation and thermalization is different, and both values are based on experimental data. The positive and negative streamer development is based on the constant electric field characteristics of these discharges, as found during experimental measurements made by different authors. As a computational tool

  7. Column-Oriented Database Systems (Tutorial)

    NARCIS (Netherlands)

    D. Abadi; P.A. Boncz (Peter); S. Harizopoulos

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as

  8. Family of columns isospectral to gravity-loaded columns with tip force: A discrete approach

    Science.gov (United States)

    Ramachandran, Nirmal; Ganguli, Ranjan

    2018-06-01

    A discrete model is introduced to analyze transverse vibration of straight, clamped-free (CF) columns of variable cross-sectional geometry under the influence of gravity and a constant axial force at the tip. The discrete model is used to determine critical combinations of loading parameters - a gravity parameter and a tip force parameter - that cause onset of dynamic instability in the CF column. A methodology, based on matrix-factorization, is described to transform the discrete model into a family of models corresponding to weightless and unloaded clamped-free (WUCF) columns, each with a transverse vibration spectrum isospectral to the original model. Characteristics of models in this isospectral family are dependent on three transformation parameters. A procedure is discussed to convert the isospectral discrete model description into geometric description of realistic columns i.e. from the discrete model, we construct isospectral WUCF columns with rectangular cross-sections varying in width and depth. As part of numerical studies to demonstrate efficacy of techniques presented, frequency parameters of a uniform column and three types of tapered CF columns under different combinations of loading parameters are obtained from the discrete model. Critical combinations of these parameters for a typical tapered column are derived. These results match with published results. Example CF columns, under arbitrarily-chosen combinations of loading parameters are considered and for each combination, isospectral WUCF columns are constructed. Role of transformation parameters in determining characteristics of isospectral columns is discussed and optimum values are deduced. Natural frequencies of these WUCF columns computed using Finite Element Method (FEM) match well with those of the given gravity-loaded CF column with tip force, hence confirming isospectrality.

  9. Distillation Column Flooding Predictor

    Energy Technology Data Exchange (ETDEWEB)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  10. Annular pulse column development studies

    International Nuclear Information System (INIS)

    Benedict, G.E.

    1980-01-01

    The capacity of critically safe cylindrical pulse columns limits the size of nuclear fuel solvent extraction plants because of the limited cross-sectional area of plutonium, U-235, or U-233 processing columns. Thus, there is a need to increase the cross-sectional area of these columns. This can be accomplished through the use of a column having an annular cross section. The preliminary testing of a pilot-plant-scale annular column has been completed and is reported herein. The column is made from 152.4-mm (6-in.) glass pipe sections with an 89-mm (3.5-in.) o.d. internal tube, giving an annular width of 32-mm (1.25-in.). Louver plates are used to swirl the column contents to prevent channeling of the phases. The data from this testing indicate that this approach can successfully provide larger-cross-section critically safe pulse columns. While the capacity is only 70% of that of a cylindrical column of similar cross section, the efficiency is almost identical to that of a cylindrical column. No evidence was seen of any non-uniform pulsing action from one side of the column to the other

  11. Column-Oriented Database Systems (Tutorial)

    OpenAIRE

    Abadi, D.; Boncz, Peter; Harizopoulos, S.

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as opposed to traditional database systems that store entire records (rows) one after the other. Reading a subset of a table’s columns becomes faster, at the potential expense of excessive disk-head s...

  12. Nuclear reactor control column

    International Nuclear Information System (INIS)

    Bachovchin, D.M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest crosssectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor

  13. The effect of an auxiliary discharge on anode sheath potentials in a transverse discharge

    International Nuclear Information System (INIS)

    Foster, J.E.; Gallimore, A.D.

    1997-01-01

    A novel scheme that employs the use of an auxiliary discharge has been shown to reduce markedly anode sheath potentials in a transverse discharge. An 8.8 A low-pressure argon discharge in the presence of a transverse magnetic field was used as the plasma source in this study. In such discharges, the transverse flux that is collected by the anode is severely limited due to marked reductions in the transverse diffusion coefficient. Findings of this study indicate that the local electron number density and the transverse flux increase when the auxiliary discharge is operated. Changes in these parameters are reflected in the measured anode sheath voltage. Anode sheath potentials, estimated by using Langmuir probes, were shown to be reduced by over 33% when the auxiliary discharge is operated. These reductions in anode sheath potentials translated into significant reductions in anode power flux as measured using water calorimeter techniques. The reductions in anode power flux also correlate well with changes in the electron transverse flux. Finally, techniques implementing these positive effects in real plasma accelerators are discussed. copyright 1997 American Institute of Physics

  14. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    Science.gov (United States)

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  15. Improvements in solvent extraction columns

    International Nuclear Information System (INIS)

    Aughwane, K.R.

    1987-01-01

    Solvent extraction columns are used in the reprocessing of irradiated nuclear fuel. For an effective reprocessing operation a solvent extraction column is required which is capable of distributing the feed over most of the column. The patent describes improvements in solvent extractions columns which allows the feed to be distributed over an increased length of column than was previously possible. (U.K.)

  16. Propagation and diffusion of a plasma column in a magnetic field; Propagation et diffusion d'une colonne de plasma dans un champ magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Bottiglioni, F; Coutant, J; Gadda, E; Prevot, F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1966-12-01

    A plasma column is created in a magnetic field by longitudinal diffusion from a low-pressure pulsed discharge in hydrogen. Depending on the discharge conditions, two regimes are obtained in which the gas pumping speed has a different effect upon the plasma density in the column. Calculations are presented which can explain this effect by a difference in the transverse diffusion coefficient. (authors) [French] On forme une colonne de plasma dans un champ magnetique par diffusion longitudinale a partir d'une decharge puisee dans l'hydrogene a basse pression. Selon les conditions de la decharge on observe deux regimes differents pour lesquels le pompage du gaz neutre a un effet different sur la densite resultante du plasma dans la colonne. On presente des calculs qui peuvent expliquer cet effet par une difference dans la diffusion transversale du plasma. (auteurs)

  17. The effect of spherical hub-nose position on pressure drop in an oscillating water column system for wave energy conversion

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Z.; Ahmad, N.; Ghazilla, R.A.R.; Yap, H.J.; Ya, T.Y.T.; Passarella, R.; Hasanuddin, I.; Yunus, M. [Malaya Univ. (Malaysia). Centre for Product Design and Manufacturing; Sugiyono [Malaya Univ., (Malaysia). Centre for Product Design and Manufacturing; Gadjah Mada Univ. (Indonesia). Dept. of Mechanical and Industrial Engineering

    2009-07-01

    The use of renewable energy sources as an alternative to conventional fuels was discussed with particular reference to ocean wave energy and its potential to contribute to the energy requirements of coastal nations. Ocean wave energy has been harnessed and converted into electricity using processes and technologies that are environmentally sound. The oscillating water column (OWC) system is considered to be among the most promising technology for harnessing wave energy. This paper presented the results of a study that investigated the pressure drop in an OWC system and the effect of spherical hub-nose position in an annular duct. Computational fluid dynamics (CFD) analysis was used under steady flow conditions for several hub-nose positions to determine the characteristic of pressure drop. The study showed that the hub-nose position influenced the pressure drop in the OWC system. The highest value of the pressure drop in this study occurred when the hub-nose was at the position of 0.0 m relative to the end of the converging cone. The pressure drop decreased when the hub-nose position moved away from the end of converging cone. The lowest value occurred at the position of -0.5 m. It was concluded that despite the numerically small change in pressure drop, this phenomenon should be considered in the design process of the OWC system because of the operational condition of the system at low-pressure pneumatic power. The pressure drop actually reduces the amount of energy that will be converted by the air turbine. 9 refs., 2 tabs., 6 figs.

  18. ( Anogeissus leiocarpus ) timber columns

    African Journals Online (AJOL)

    A procedure for designing axially loaded Ayin (Anogeissus leiocarpus) wood column or strut has been investigated. Instead of the usual categorization of columns into short, intermediate and slender according to the value of slenderness ratio, a continuous column formula representing the three categories was derived.

  19. Numerical study on the discharge characteristics and nonlinear behaviors of atmospheric pressure coaxial electrode dielectric barrier discharges

    International Nuclear Information System (INIS)

    Zhang Ding-Zong; Wang Yan-Hui; Wang De-Zhen

    2017-01-01

    The discharge characteristics and temporal nonlinear behaviors of the atmospheric pressure coaxial electrode dielectric barrier discharges are studied by using a one-dimensional fluid model. It is shown that the discharge is always asymmetrical between the positive pulses and negative pulses. The gas gap severely affects this asymmetry. But it is hard to acquire a symmetrical discharge by changing the gas gap. This asymmetry is proportional to the asymmetric extent of electrode structure, namely the ratio of the outer electrode radius to the inner electrode radius. When this ratio is close to unity, a symmetrical discharge can be obtained. With the increase of frequency, the discharge can exhibit a series of nonlinear behaviors such as period-doubling bifurcation, secondary bifurcation and chaotic phenomena. In the period-doubling bifurcation sequence the period- n discharge becomes more and more unstable with the increase of n . The period-doubling bifurcation can also be obtained by altering the discharge gas gap. The mechanisms of two bifurcations are further studied. It is found that the residual quasineutral plasma from the previous discharges and corresponding electric field distribution can weaken the subsequent discharge, and leads to the occurrence of bifurcation. (paper)

  20. LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  1. Hydrogen discharges operating at atmospheric pressure in a semiconductor gas discharge system

    Energy Technology Data Exchange (ETDEWEB)

    Aktas, K; Acar, S; Salamov, B G [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)

    2011-08-15

    Analyses of physical processes which initiate electrical breakdown and spatial stabilization of current and control it with a photosensitive cathode in a semiconductor gas discharge system (SGDS) are carried out in a wide pressure range up to atmospheric pressure p, interelectrode distance d and diameter D of the electrode areas of the semiconductor cathode. The study compares the breakdown and stability curves of the gas discharge in the planar SGDS where the discharge gap is filled with hydrogen and air in two cases. The impact of the ionizing component of the discharge plasma on the control of the stable operation of the planar SGDS is also investigated at atmospheric pressure. The loss of stability is primarily due to modification of the semiconductor-cathode properties on the interaction with low-energy hydrogen ions and the formation of a space charge of positive ions in the discharge gap which changes the discharge from Townsend to glow type. The experimental results show that the discharge current in H{sub 2} is more stable than in air. The breakdown voltages are measured for H{sub 2} and air with parallel-plane electrodes, for pressures between 28 and 760 Torr. The effective secondary electron emission (SEE) coefficient is then determined from the breakdown voltage results and compared with the experimental results. The influence of the SEE coefficient is stated in terms of the differences between the experimental breakdown law.

  2. FTIR study of decomposition of carbon dioxide in dc corona discharges

    International Nuclear Information System (INIS)

    Horvath, G; Skalny, J D; Mason, N J

    2008-01-01

    The decomposition rate of carbon dioxide and the generation of ozone and carbon monoxide in coaxial corona discharges fed by pure CO 2 has been investigated in a dc corona discharge operated in both positive and negative polarities using FTIR spectroscopy. The degree of CO 2 decomposition is found to be dependent on the voltage, U, with a maximum CO 2 decomposition of nearly 10% found in a negative corona discharge for U = 7.5 kV. In all cases the amount of CO 2 decomposition was lower in positive polarity discharges than in negative polarity discharges operated under same conditions. CO and ozone were found to be the main products observed in the discharges.

  3. FTIR study of decomposition of carbon dioxide in dc corona discharges

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, G; Skalny, J D [Department of Experimental Physics, Comenius University, Mlynska dolina F-2, 842 48, Bratislava (Slovakia); Mason, N J [Open University, Department of Physics and Astronomy, Walton Hall, Milton Keynes MK7 6AA (United Kingdom)

    2008-11-21

    The decomposition rate of carbon dioxide and the generation of ozone and carbon monoxide in coaxial corona discharges fed by pure CO{sub 2} has been investigated in a dc corona discharge operated in both positive and negative polarities using FTIR spectroscopy. The degree of CO{sub 2} decomposition is found to be dependent on the voltage, U, with a maximum CO{sub 2} decomposition of nearly 10% found in a negative corona discharge for U = 7.5 kV. In all cases the amount of CO{sub 2} decomposition was lower in positive polarity discharges than in negative polarity discharges operated under same conditions. CO and ozone were found to be the main products observed in the discharges.

  4. Automation of column-based radiochemical separations. A comparison of fluidic, robotic, and hybrid architectures

    Energy Technology Data Exchange (ETDEWEB)

    Grate, J.W.; O' Hara, M.J.; Farawila, A.F.; Ozanich, R.M.; Owsley, S.L. [Pacific Northwest National Laboratory, Richland, WA (United States)

    2011-07-01

    Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on using disposable components so that no sample contacts any surface that any other sample has contacted, and setting up samples and columns in parallel for subsequent automated processing. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions one of four rows of six vials below the columns. The samples are delivered to each column via a manual 3-port disposable valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is a simpler more efficient approach for performing anion exchange procedures for the recovery and purification of plutonium from samples. The automation architectures described can also be adapted to column-based extraction chromatography separations. (orig.)

  5. Simulation of convection-stabilized low-current glow and arc discharges in atmospheric-pressure air

    International Nuclear Information System (INIS)

    Naidis, G V

    2007-01-01

    A two-dimensional model of stationary convection-stabilized low-current glow and arc discharge columns in atmospheric-pressure air is developed which accounts for deviation of the plasma state from the local thermodynamic equilibrium (LTE). In addition to equations of energy, continuity and momentum (analogous to those used in LTE arc models), the non-LTE model includes balance equations for plasma species and for the vibrational energy of nitrogen molecules. The kinetic scheme is used which was developed recently for the simulation of low-current wall-stabilized discharges in air. Results of calculation of discharge parameters over a wide current range are presented. It is shown that the non-equilibrium effects are substantial at currents lower than ∼ 100 mA. The calculated plasma parameters agree with available experimental data

  6. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  7. Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.

    Science.gov (United States)

    Estabrook, Neil C; Corn, Jonathan B; Ewing, Marvene M; Cardenes, Higinia R; Das, Indra J

    2018-02-01

    Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer. Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively. Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed. CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.

  8. High salinity tolerance of the Red Sea coral Fungia granulosa under desalination concentrate discharge conditions: an in situ photophysiology experiment

    KAUST Repository

    Van Der Merwe, Riaan; Rö thig, Till; Voolstra, Christian R.; Ochsenkuhn, Michael A.; Lattemann, Sabine; Amy, Gary L.

    2014-01-01

    - specific, and also depends on the salinity tolerance of the organisms inhabiting the water column in and around a discharge environment. Scientific studies that aim to understand possible impacts of elevated salinity levels are important to assess

  9. Waveform generation in the weakly electric fish Gymnotus coropinae (Hoedeman): the electric organ and the electric organ discharge.

    Science.gov (United States)

    Castelló, María E; Rodríguez-Cattáneo, Alejo; Aguilera, Pedro A; Iribarne, Leticia; Pereira, Ana Carolina; Caputi, Angel A

    2009-05-01

    This article deals with the electric organ and its discharge in Gymnotus coropinae, a representative species of one of the three main clades of the genus. Three regions with bilateral symmetry are described: (1) subopercular (medial and lateral columns of complex shaped electrocytes); (2) abdominal (medial and lateral columns of cuboidal and fusiform electrocytes); and (3) main [four columns, one dorso-lateral (containing fusiform electrocytes) and three medial (containing cuboidal electrocytes)]. Subopercular electrocytes are all caudally innervated whereas two of the medial subopercular ones are also rostrally innervated. Fusiform electrocytes are medially innervated at the abdominal portion, and at their rostral and caudal poles at the main portion. Cuboidal electrocytes are always caudally innervated. The subopercular portion generates a slow head-negative wave (V(1r)) followed by a head-positive spike (V(3r)). The abdominal and main portions generate a fast tetra-phasic complex (V(2345ct)). Since subopercular components prevail in the near field and the rest in the far field, time coincidence of V(3r) with V(2) leads to different waveforms depending on the position of the receiver. This confirms the splitting hypothesis of communication and exploration channels based on the different timing, frequency band and reach of the regional waveforms. The following hypothesis is compatible with the observed anatomo-functional organization: V(1r) corresponds to the rostral activation of medial subopercular electrocytes and V(3r) to the caudal activation of all subopercular electrocytes; V(2), and part of V(3ct), corresponds to the successive activation of the rostral and caudal poles of dorso-lateral fusiform electrocytes; and V(345ct) is initiated in the caudal face of cuboidal electrocytes by synaptic activation (V(3ct)) and it is completed (V(45ct)) by the successive activation of rostral and caudal faces by the action currents evoked in the opposite face.

  10. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    Science.gov (United States)

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  11. Discharge cleaning for a tokamak

    International Nuclear Information System (INIS)

    Ishii, Shigeyuki

    1983-01-01

    Various methods of discharge cleaning for tokamaks are described. The material of the first walls of tokamaks is usually stainless steel, inconel, titanium and so on. Hydrogen is exclusively used as the discharge gas. Glow discharge cleaning (GDC), Taylor discharge cleaning (TDC), and electron cyclotron resonance discharge cleaning (ECR-DC) are discussed in this paper. The cleaning by GDC is made by moving a movable anode to the center of a tokamak vassel. Taylor found the good cleaning effect of induced discharge by high pressure and low power discharge. This is called TDC. When the frequency of high frequency discharge in a magnetic field is equal to that of the electron cyclotron resonance, the break down potential is lowered if the pressure is sufficiently low. The ECR-CD is made by using this effect. In TDC and ECR-DC, the electron temperature, which has a close relation to the production rate of H 0 , can be controlled by the pressure. In GDC, the operating pressure was improved by the radio frequency glow (RG) method. However, there is still the danger of arcing. In case of GDC and ECR-DC, the position of plasma can be controlled, but not in case of TDC. The TDC is accepted by most of takamak devices in the world. (Kato, T.)

  12. Sorption of nitrate onto amine-crosslinked wheat straw: characteristics, column sorption and desorption properties.

    Science.gov (United States)

    Xing, Xu; Gao, Bao-Yu; Zhong, Qian-Qian; Yue, Qin-Yan; Li, Qian

    2011-02-15

    The nitrate removal process was evaluated using a fixed-bed column packed with amine-crosslinked wheat straw (AC-WS). Column sorption and desorption characteristics of nitrate were studied extensively. Solid-state (13)C NMR and zeta potential analysis validated the existence of crosslinked amine groups in AC-WS. Raman shift of the nitrate peaks suggested the electrostatic attraction between the adsorbed ions and positively charged amine sites. The column sorption capacity (q(ed)) of the AC-WS for nitrate was 87.27 mg g(-1) in comparison with the raw WS of 0.57 mg g(-1). Nitrate sorption in column was affected by bed height, influent nitrate concentration, flow rate and pH, and of all these, influent pH demonstrated an essential effect on the performance of the column. In addition, desorption and dynamic elution tests were repeated for several cycles, with high desorption rate and slight losses in its initial column sorption capacity. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  14. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  15. Mass transfer model liquid phase catalytic exchange column simulation applicable to any column composition profile

    Energy Technology Data Exchange (ETDEWEB)

    Busigin, A. [NITEK USA Inc., Ocala, FL (United States)

    2015-03-15

    Liquid Phase Catalytic Exchange (LPCE) is a key technology used in water detritiation systems. Rigorous simulation of LPCE is complicated when a column may have both hydrogen and deuterium present in significant concentrations in different sections of the column. This paper presents a general mass transfer model for a homogenous packed bed LPCE column as a set of differential equations describing composition change, and equilibrium equations to define the mass transfer driving force within the column. The model is used to show the effect of deuterium buildup in the bottom of an LPCE column from non-negligible D atom fraction in the bottom feed gas to the column. These types of calculations are important in the design of CECE (Combined Electrolysis and Catalytic Exchange) water detritiation systems.

  16. Development of high power pumping system for capillary discharge EUV laser

    International Nuclear Information System (INIS)

    Sakai, Yusuke; Komatsu, Takanori; Watanabe, Masato; Okino, Akitoshi; Hotta, Eiki

    2008-01-01

    Development of high power pumping system for capillary discharge soft X-ray laser is reported. The pulsed power system consists of a 2.2 μF LC generator, a 2:54 step-up transformer and a 3 nF water capacitor. Taking advantage of high efficiency configuration, step-up ratio of water capacitor voltage to LC generator initial voltage is about 40 times. Consequently, obtained water capacitor voltage reaches about 450 kV when LC generator was charged to 12.5 kV. As a consequent, possibility of charging a water capacitor to 1 MV is demonstrated. With this extremely compact system, discharge current could be increased to nearly 100 kA through moderately long capillary, which leads to generation of high-density and high-temperature plasma column in order to realize EUV laser. (author)

  17. Interplay between intrinsic plasma rotation and magnetic island evolution in disruptive discharges

    Energy Technology Data Exchange (ETDEWEB)

    Ronchi, G.; Severo, J. H. F. [Universidade de São Paulo, Instituto de Física (Brazil); Salzedas, F. [Universidade do Porto, Faculdade de Engenharia (Portugal); Galvão, R. M. O., E-mail: rgalvao@if.usp.br; Sanada, E. K. [Universidade de São Paulo, Instituto de Física (Brazil)

    2016-05-15

    The behavior of the intrinsic toroidal rotation of the plasma column during the growth and eventual saturation of m/n = 2/1 magnetic islands, triggered by programmed density rise, has been carefully investigated in disruptive discharges in TCABR. The results show that, as the island starts to grow and rotate at a speed larger than that of the plasma column, the angular frequency of the intrinsic toroidal rotation increases and that of the island decreases, following the expectation of synchronization. As the island saturates at a large size, just before a major disruption, the angular speed of the intrinsic rotation decreases quite rapidly, even though the island keeps still rotating at a reduced speed. This decrease of the toroidal rotation is quite reproducible and can be considered as an indicative of disruption.

  18. Study of the striated nature of a glow discharge.; Estudio de la naturaleza estratificada de una descarga de resplandor.

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez A, M

    1995-10-01

    In an investigation in progress here, plasma diagnostics and detection of standing and moving striations is being made in a discharge in Argon at pressures of 2 x 10{sup -1} to 9 x 10{sup -1} mb and currents of 2 to 9 m-amp inside an discharge tube. Measurement of the temperature of the electrons, the concentration of electrons and the plasma potential are obtained in different places of the discharge by the double probe method, together with the computation system reported in [1]. In similar way an experimental work of the striated column in a discharge plasma to find the regimen of appearance of the standing and moving striations show some properties of moving striations (frequency and velocity) and standing striations. Two different oscilations are observed in motion in contrary directions along the discharge tube with a photomultiplier. (Author).

  19. Impact of Holes on the Buckling of RHS Steel Column

    Directory of Open Access Journals (Sweden)

    Najla'a H. AL-Shareef

    2018-03-01

    Full Text Available This study presented an experimental and theoretical study on the effect of hole on the behavior of rectangular hollow steel columns subjected to axial compression load. Specimens were tested to investigated the ultimate capacity and the load- axial displacement behavior of steel columns. In this paper finite element analysis is done by using general purpose ANSYS 12.0 to investigate the behavior of rectangular hollow steel column with hole. In the experimental work, rectangular hollow steel columns with rounded corners were used in the constriction of the specimens which have dimensions of cross section (50*80mm and height of (250 and 500mm with thickness of (1.25,4 and 6mm with hole ((α*80*80mm when α is equal to (0.2,0.4,0.6 and 0.8. Twenty four columns under compression load were tested in order to investigate the effect of hole on the ultimate load of rectangular hollow steel column. The experimental results indicated that the typical failure  mode for all the tested hollow specimen was the local buckling. The tested results indicated that the increasing of hole dimension leads to reduction in ultimate loads of tested column to 75%. The results show the reducing of load by 94.7% due to decreasing  the thickness of  column while the hole size is constant (0.2*80*80. The buckling load decreases by 84.62% when hole position changes from Lo=0.25L to 0.75L. Holes can be made in the middle of column with dimension up to 0.4 of column's length. The AISC (2005 presents the values closest to the experimental results for the nominal yielding compressive strength. The effect for increasing of slendeness ratio and thickness to area ratio(t/A leading to decreacing the critical stresses and the failure of column with large size of hole and (t/A ratio less than 0.74% was due to lacal  buckling while the global buckling failure was abserve for column with small size of hole and (t/A ratio above than 0.74%. The compersion  between the experimental

  20. Seasonal arsenic accumulation in stream sediments at a groundwater discharge zone.

    Science.gov (United States)

    MacKay, Allison A; Gan, Ping; Yu, Ran; Smets, Barth F

    2014-01-21

    Seasonal changes in arsenic and iron accumulation rates were examined in the sediments of a brook that receives groundwater discharges of arsenic and reduced iron. Clean glass bead columns were deployed in sediments for known periods over the annual hydrologic cycle to monitor changes in arsenic and iron concentrations in bead coatings. The highest accumulation rates occurred during the dry summer period (July-October) when groundwater discharges were likely greatest at the sample locations. The intermediate flow period (October-March), with higher surface water levels, was associated with losses of arsenic and iron from bead column coatings at depths below 2-6 cm. Batch incubations indicated iron releases from solids to be induced by biological reduction of iron (oxy)hydroxide solids. Congruent arsenic releases during incubation were limited by the high arsenic sorption capacity (0.536 mg(As)/mg(Fe)) of unreacted iron oxide solids. The flooded spring (March-June) with high surface water flows showed the lowest arsenic and iron accumulation rates in the sediments. Comparisons of accumulation rates across a shoreline transect were consistent with greater rates at regions exposed above surface water levels for longer times and greater losses at locations submerged below surface water. Iron (oxy)hydroxide solids in the shallowest sediments likely serve as a passive barrier to sorb arsenic released to pore water at depth by biological iron reduction.

  1. The Position and Mobility of the Shoulder, Spinal Column and Pelvis in Seated Subjects.

    Science.gov (United States)

    1985-02-01

    Considerable muscle atrophy was observed in the right shoulder. In the spinal column, tissues overlying the right sacroiliac joint felt firmer than over...subject #23 had fewer clinical findings for joint dysfunction than in the other two subjects, but the physician noted more soft tissue observations than...There was also a mild scoliotic curvature with left convexity observed at T4-6. n the pelvis, the left lumbosacral and sacroiliac joints seened to

  2. Observations of propagating double layers in a high current discharge

    International Nuclear Information System (INIS)

    Lindberg, L.

    1988-01-01

    Observations of current disruptions and strong electric fields along the magnetic field in a high-density (2 x 10 19 m - 3 , highly-ionized, moving, and expanding plasma column are reported. The electric field is interpreted in terms of propagating, strong electric double layers (3-5kV). An initial plasma column is formed in an axial magnetic field (0.1T) by means of a conical theta-pinch plasma gun. When an axial current (max 5kA, 3-5 kV) is drawn through the column spontaneous disruptions and double-layer formation occur within a few microseconds. Floating, secondary emitting Langmuir probes are used. They often indicate very high positive potential peaks (1-2 kV above the anode potential during a few μs) in the plasma on the positive side of the double layer. Short, intense bursts of HF radiation are detected at the disruptions

  3. Two generalizations of column-convex polygons

    International Nuclear Information System (INIS)

    Feretic, Svjetlan; Guttmann, Anthony J

    2009-01-01

    Column-convex polygons were first counted by area several decades ago, and the result was found to be a simple, rational, generating function. In this work we generalize that result. Let a p-column polyomino be a polyomino whose columns can have 1, 2, ..., p connected components. Then column-convex polygons are equivalent to 1-convex polyominoes. The area generating function of even the simplest generalization, namely 2-column polyominoes, is unlikely to be solvable. We therefore define two classes of polyominoes which interpolate between column-convex polygons and 2-column polyominoes. We derive the area generating functions of those two classes, using extensions of existing algorithms. The growth constants of both classes are greater than the growth constant of column-convex polyominoes. Rather tight lower bounds on the growth constants complement a comprehensive asymptotic analysis.

  4. Dynamic Characteristics of Positive Pulsed Dielectric Barrier Discharge for Ozone Generation in Air

    Science.gov (United States)

    Wei, Linsheng; Peng, Bangfa; Li, Ming; Zhang, Yafang; Hu, Zhaoji

    2016-02-01

    A comprehensive dynamic model consisting of 66 reactions and 24 species is developed to investigate the dynamic characteristics of ozone generation by positive pulsed dielectric barrier discharge (DBD) using parallel-plate reactor in air. The electron energy conservation equation is coupled to the electron continuity equation, the heavy species continuity equation, and Poisson's equation for a better description. The reliability of the model is experimentally confirmed. The model can be used to predict the temporal and spatial evolution of species, as well as streamer propagation. The simulation results show that electron density increases nearly exponentially in the direction to the anode at the electron avalanche. Streamer propagation velocity is about 5.26 × 104 m/s from anode to cathode in the simulated condition. The primary positive ion, negative ion, and excited species are O2+, O3- and O2(1Δg) in pulsed DBD in air, respectively. N2O has the largest density among nitrogen oxides. e and N2+ densities in the streamer head increase gradually to maximum values with the development of the streamer. Meanwhile, the O2+, O, O3, N2(A3Σ) and N2O densities reach maximum values in the vicinity of the anode. supported by National Natural Science Foundation of China (Nos. 51366012 and 11105067), Jiangxi Province Young Scientists (Jinggang Star) Cultivation Plan of China (No. 20133BCB23008), Natural Science Foundation of Jiangxi, China (No. 20151BAB206047) and Jiangxi Province Higher School Science and Technology Landing Plan of China (No. KJLD-14015)

  5. Mode suppression of a two-dimensional potential relaxation instability in a weakly magnetized discharge plasma

    Science.gov (United States)

    Gyergyek, T.; Čerček, M.; Jelić, N.; Stanojević, M.

    1993-05-01

    A potential relaxation instability (PRI) is modulated by an external signal using an additional grid to modulate the radial plasma potential profile in a magnetized plasma column in a linear magnetized discharge plasma device. It is observed that the electrode current oscillations follow the van der Pol equation with an external forcing term, and the linear growth rate of the instability is measured.

  6. The nonlocal electron kinetics for a low-pressure glow discharge dusty plasma

    Science.gov (United States)

    Liang, Yonggan; Wang, Ying; Li, Hui; Tian, Ruihuan; Yuan, Chengxun; Kudryavtsev, A. A.; Rabadanov, K. M.; Wu, Jian; Zhou, Zhongxiang; Tian, Hao

    2018-05-01

    The nonlocal electron kinetic model based on the Boltzmann equation is developed in low-pressure argon glow discharge dusty plasmas. The additional electron-dust elastic and inelastic collision processes are considered when solving the kinetic equation numerically. The orbital motion limited theory and collision enhanced collection approximation are employed to calculate the dust surface potential. The electron energy distribution function (EEDF), effective electron temperature Teff, and dust surface potential are investigated under different plasma and dust conditions by solving the Boltzmann and the dust charging current balance equations self-consistently. A comparison of the calculation results obtained from nonlocal and local kinetic models is made. It is shown that the appearance of dust particles leads to a deviation of the EEDF from its original profile for both nonlocal and local kinetic models. With the increase in dust density and size, the effective electron temperature and dust surface potential decrease due to the high-energy electron loss on the dust surface. Meanwhile, the nonlocal and local results differ much from each other under the same calculation condition. It is concluded that, for low-pressure (PR ≤ 1 cm*Torr) glow discharge dusty plasmas, the existence of dust particles will amplify the difference of local and nonlocal EEDFs, which makes the local kinetic model more improper to determine the main parameters of the positive column. The nonlocal kinetic model should be used for the calculation of the EEDFs and dusty plasma parameters.

  7. Capillary trap column with strong cation-exchange monolith for automated shotgun proteome analysis.

    Science.gov (United States)

    Wang, Fangjun; Dong, Jing; Jiang, Xiaogang; Ye, Mingliang; Zou, Hanfa

    2007-09-01

    A 150 microm internal diameter capillary monolithic column with a strong cation-exchange stationary phase was prepared by direct in situ polymerization of ethylene glycol methacrylate phosphate and bisacrylamide in a trinary porogenic solvent consisting dimethylsulfoxide, dodecanol, and N,N'-dimethylformamide. This phosphate monolithic column exhibits higher dynamic binding capacity, faster kinetic adsorption of peptides, and more than 10 times higher permeability than the column packed with commercially available strong cation-exchange particles. It was applied as a trap column in a nanoflow liquid chromatography-tandem mass spectrometry system for automated sample injection and online multidimensional separation. It was observed that the sample could be loaded at a flow rate as high as 40 microL/min with a back pressure of approximately 1300 psi and without compromising the separation efficiency. Because of its good orthogonality to the reversed phase separation mechanism, the phosphate monolithic trap column was coupled with a reversed-phase column for online multidimensional separation of 19 microg of the tryptic digest of yeast proteins. A total of 1522 distinct proteins were identified from 5608 unique peptides (total of 54,780 peptides) at the false positive rate only 0.46%.

  8. Experimental analysis of reinforced concrete columns strengthened with self-compacting concrete and connectors

    Directory of Open Access Journals (Sweden)

    P. P. Nascimento

    Full Text Available There are many problems involving cases of destruction of buildings and other structures. The columns can deteriorate for several reasons such as the evolution and changing habits of the loads. The experimental phase of this work was based on a test involving nine reinforced concrete columns under combined bending and axial compression, at an initial eccentricity of 60 mm. Two columns were used as reference, one having the original dimensions of the column and the other, monolithic, had been cast along the thickness of the strengthened piece. The remaining columns received a 35 mm thick layer of self-compacting concrete on their compressed face. For the preparation of the interface between the two materials, this surface was scarified and furrowed and connectors were inserted onto the columns' shear reinforcement in various positions and amounts.As connectors, 5 mm diameter steel bars were used (the same as for stirrups, bent in the shape of a "C" with 25 mm coatings. >As a conclusion, not only the quantity, but mainly, the location of the connectors used in the link between substrate and reinforcement is crucial to increase strength and to change failure mode.

  9. Numerical simulation of transitions between back discharge regimes

    International Nuclear Information System (INIS)

    Jansky, Jaroslav; Lemont, Florent; Bessieres, Delphine; Paillol, Jean

    2014-01-01

    This paper presents numerical simulations of transitions between back discharge regimes. Back discharge refers to any discharge initiated at or near a dielectric layer covering a passive electrode. In this work, a pinhole in a dielectric layer on a plane anode serves as a model for back discharge activity. We have studied transitions between back discharge regimes by varying the surface charge density on the dielectric layer and the electric field in front of the pinhole. From the variation of these two independent parameters, the back discharge regimes have been depicted as a mode diagram inspired by the experimental study of Masuda and Mizuno. The resulting diagram includes the different discharge regimes that are commonly observed in experiments. The propagation of a positive ionizing wave inside the pinhole toward its edge, and the resulting formation of a plasma zone at its exit constitute the onset stage of back discharge. From this stage, the transitions to volume discharge or surface discharge can occur. The volume discharge regime consists of the propagation of a discharge in space toward the cathode which can be superimposed with the propagation of a discharge above the dielectric layer surface. The diagram reveals the conditions for transitions between back discharge regimes. (authors)

  10. The discharge of nitrate-contaminated groundwater from developed shoreline to marsh-fringed estuary

    Science.gov (United States)

    Portnoy, J.W.; Nowicki, B.L.; Roman, C.T.; Urish, D.W.

    1998-01-01

    As residential development, on-site wastewater disposal, and groundwater contamination increase in the coastal zone, assessment of nutrient removal by soil and sedimentary processes becomes increasingly important. Nitrogen removal efficiency depends largely on the specific flow paths taken by groundwater as it discharges into nitrogen-limited estuarine waters. Shoreline salinity surveys, hydraulic studies, and thermal infrared imagery indicated that groundwater discharge into the Nauset Marsh estuary (Eastham, Massachusetts) occurred in high-velocity seeps immediately seaward of the upland-fringing salt marsh. Discharge was highly variable spatially and occurred through permeable, sandy sediments during low tide. Seepage chamber monitoring showed that dissolved inorganic nitrogen (principally nitrate) traversed nearly conservatively from the aquifer through shallow estuarine sediments to coastal waters at flux rates of 1–3 mmol m−2 h−1. A significant relationship between pore water NO3-N concentrations and NO3-N flux rates may provide a rapid method of estimating nitrogen loading from groundwater to the water column.

  11. The influence of the nitrogen admixture on the evolution of a deuterium pinch column

    Energy Technology Data Exchange (ETDEWEB)

    Kubes, P.; Cikhardtova, B.; Cikhardt, J.; Klir, D.; Kravarik, J.; Rezac, K.; Kortanek, J. [Czech Technical University, 166-27 Prague (Czech Republic); Paduch, M.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion, 01-497 Warsaw (Poland); Sadowski, M. J. [Institute of Plasma Physics and Laser Microfusion, 01-497 Warsaw (Poland); National Centre for Nuclear Research, 05-400 Otwock-Świerk (Poland); Tomaszewski, K. [ACS Ltd., 01-497 Warsaw (Poland)

    2016-08-15

    The application of a mixture of nitrogen and deuterium for the gas-puffing along the anode axis in deuterium plasma-focus discharges, as carried out at megaampere-level currents, enabled observations of the filamentary structure, and the decrease in the transformation velocity of the plasma column to be performed. It made possible to investigate the instability evolution during the production of hard X-rays and fast neutrons in more detail. The constriction of a plasma column transforms itself during the final phase of the compression into one or more small dense plasmoid-like structures which are separated by narrow necks. During the next phase, these structures start to decay by an expansion, in which a part of the plasma volume maintains its compactness. This evolution is explained by an increase and later decrease in the internal poloidal current component by reconnections of the associated magnetic lines, which are responsible for the acceleration of electron and ion beams.

  12. Risk assessment for produced water discharges to Louisiana Open Bays

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; DePhillips, M.P.; Holtzman, S.

    1995-06-23

    Data were collected prior to termination of discharge at three sites (including two open bay sites at Delacroix Island and Bay De Chene) for the risk assessments. The Delacroix Island Oil and Gas Field has been in production since the first well drilling in 1940; the Bay De Chene Field, since 1942. Concentrations of 226Ra, 228Ra, 210Po, and 228Th were measured in discharges. Radium conc. were measured in fish and shellfish tissues. Sediment PAH and metal conc. were also available. Benthos sampling was conducted. A survey of fishermen was conducted. The tiered risk assessment showed that human health risks from radium in produced water appear to be small; ecological risk from radium and other radionuclides in produced water also appear small. Many of the chemical contaminants discharged to open Louisiana bays appear to present little human health or ecological risk. A conservative screening analysis suggested potential risks to human health from Hg and Pb and a potential risk to ecological receptors from total effluent, Sb, Cd, Cu, Pb, Ni, Ag, Zn, and phenol in the water column and PAHs in sediment; quantitiative risk assessments are being done for these contaminants.

  13. Long-Term Charge/Discharge Cycling Stability of MnO2 Aqueous Supercapacitor under Positive Polarization

    KAUST Repository

    Ataherian, Fatemeh

    2011-01-01

    The long-term charge/discharge cycling stability of MnO 2 electrode under positive polarization in aqueous KCl electrolyte has been studied over different potential windows spanning from the open circuit potential to varied higher-end potential limited by O 2 evolution. Cycling up to 1.2 V (vs Ag/AgCl (aq)) causes partial (35) capacitance fading to a plateau value within the initial cycles, accompanied by morphological reconstruction, reduction of surface Mn ions and oxygen evolution. The surface Mn-ion reduction has been attributed to a two-step oxidation-reduction mechanism involving OH oxidation in electrolyte, based on electrochemical analysis. When cycling potential extends to 1.4 V, extensive oxygen evolution takes place. The combination of surface passivation of current collector and extensive gas bubbling, which deteriorates electrical contact among the constituent particles within the electrode, results in further monotonic capacitance reduction. © 2011 The Electrochemical Society.

  14. Angina - discharge

    Science.gov (United States)

    Chest pain - discharge; Stable angina - discharge; Chronic angina - discharge; Variant angina - discharge; Angina pectoris - discharge; Accelerating angina - discharge; New-onset angina - discharge; Angina-unstable - discharge; ...

  15. Adsorption of phosphate from aqueous solutions and sewage using zirconium loaded okara (ZLO): Fixed-bed column study

    International Nuclear Information System (INIS)

    Nguyen, T.A.H.; Ngo, H.H.; Guo, W.S.; Pham, T.Q.; Li, F.M.; Nguyen, T.V.; Bui, X.T.

    2015-01-01

    This study explores the potential of removing phosphorus from aqueous solutions and sewage by Zr(IV)-loaded okara (ZLO) in the fixed-bed column. Soybean residue (okara) was impregnated with 0.25 M Zr(IV) solution to prepare active binding sites for phosphate. The effect of several factors, including flow rate, bed height, initial phosphorus concentration, pH and adsorbent particle size on the performance of ZLO was examined. The maximum dynamic adsorption capacity of ZLO for phosphorus was estimated to be 16.43 mg/g. Breakthrough curve modeling indicated that Adams–Bohart model and Thomas model fitted the experimental data better than Yoon–Nelson model. After treatment with ZLO packed bed column, the effluent could meet the discharge standard for phosphorus in Australia. Successful desorption and regeneration were achieved with 0.2 NaOH and 0.1 HCl, respectively. The results prove that ZLO can be used as a promising phosphorus adsorbent in the dynamic adsorption system. - Highlights: • Dynamic adsorption of P from water and wastewater by Zr(IV)-loaded okara was tested. • Effects of column design parameters on the adsorption performance were investigated. • The dynamic adsorption capacity of Zr(IV)-loaded okara for P was reasonably high. • The spent column was effectively regenerated with 0.2 M NaOH followed by 0.1 M HCl. • Zr(IV)-loaded okara column was efficient in eliminating P from municipal sewage

  16. Adsorption of phosphate from aqueous solutions and sewage using zirconium loaded okara (ZLO): Fixed-bed column study

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.A.H. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Ngo, H.H., E-mail: ngohuuhao121@gmail.com [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Guo, W.S. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Pham, T.Q. [Faculty of Geography, University of Science, Vietnam National University, Hanoi (Viet Nam); Li, F.M. [College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100 (China); Nguyen, T.V. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Bui, X.T. [Environmental Engineering and Management Research Group, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology-Vietnam National University, Ho Chi Minh City (Viet Nam)

    2015-08-01

    This study explores the potential of removing phosphorus from aqueous solutions and sewage by Zr(IV)-loaded okara (ZLO) in the fixed-bed column. Soybean residue (okara) was impregnated with 0.25 M Zr(IV) solution to prepare active binding sites for phosphate. The effect of several factors, including flow rate, bed height, initial phosphorus concentration, pH and adsorbent particle size on the performance of ZLO was examined. The maximum dynamic adsorption capacity of ZLO for phosphorus was estimated to be 16.43 mg/g. Breakthrough curve modeling indicated that Adams–Bohart model and Thomas model fitted the experimental data better than Yoon–Nelson model. After treatment with ZLO packed bed column, the effluent could meet the discharge standard for phosphorus in Australia. Successful desorption and regeneration were achieved with 0.2 NaOH and 0.1 HCl, respectively. The results prove that ZLO can be used as a promising phosphorus adsorbent in the dynamic adsorption system. - Highlights: • Dynamic adsorption of P from water and wastewater by Zr(IV)-loaded okara was tested. • Effects of column design parameters on the adsorption performance were investigated. • The dynamic adsorption capacity of Zr(IV)-loaded okara for P was reasonably high. • The spent column was effectively regenerated with 0.2 M NaOH followed by 0.1 M HCl. • Zr(IV)-loaded okara column was efficient in eliminating P from municipal sewage.

  17. Development of spent salt treatment technology by zeolite column system. Performance evaluation of zeolite column

    International Nuclear Information System (INIS)

    Miura, Hidenori; Uozumi, Koichi

    2009-01-01

    At electrorefining process, fission products(FPs) accumulate in molten salt. To avoid influence on heating control by decay heat and enlargement of FP amount in the recovered fuel, FP elements must be removed from the spent salt of the electrorefining process. For the removal of the FPs from the spent salt, we are investigating the availability of zeolite column system. For obtaining the basic data of the column system, such as flow property and ion-exchange performance while high temperature molten salt is passing through the column, and experimental apparatus equipped with fraction collector was developed. By using this apparatus, following results were obtained. 1) We cleared up the flow parameter of column system with zeolite powder, such as flow rate control by argon pressure. 2) Zeolite 4A in the column can absorb cesium that is one of the FP elements in molten salt. From these results, we got perspective on availability of the zeolite column system. (author)

  18. Dividing wall column: Improving thermal efficiency, energy savings and economic performance

    International Nuclear Information System (INIS)

    Aurangzeb, Md; Jana, Amiya K.

    2016-01-01

    Highlights: • A rigorous model is developed for a dividing wall column. • Heat transfer model for metal wall is proposed. • Performance improvement is quantified for a ternary system. • Thermal efficiency, energy savings and cost are three used indices. - Abstract: This work aims at investigating the performance improvement of a dividing wall column (DWC) for the separation of a ternary system. It is true that for fractionating a ternary mixture, at least a sequence of two conventional distillation columns is required. To improve energetic and economic potential, and reduce space requirement, two columns are proposed to merge into one shell with a dividing wall. For developing the mathematical model of a distillation column, we consider the effect of heat transfer through the metal wall placed at an intermediated position inside the cylindrical column. The simulated DWC model is verified using the Aspen Plus flowsheet simulator with a wide variety of phase equilibrium models. The superiority of this proposed heat integrated configuration is shown for a ternary hydrocarbon system over a conventional distillation sequence (CDS) in terms of mainly three performance indexes, namely thermal efficiency, energy savings and total annual cost (TAC). It is investigated that the dividing wall distillation scheme can secure a 37.5% energy efficiency, and a 22.6% savings in energy consumption and 23.23% in TAC. The promising performance can also be quantified in terms of a reasonably low payback period of 2.11 years.

  19. Final design and construction issues of the TAPIRO epithermal column

    International Nuclear Information System (INIS)

    Burn, K.W.; Casalini, L.; Nava, E.; Tinti, R.; Martini, S.; Mondini, D.; Rosi, G.

    2006-01-01

    The construction of the epithermal column for clinical trials at the 5 kW fast reactor TAPIRO (ENEA, Casaccia, Italy) has been completed, the experimental bunker in the reactor hall has been designed and the beam characterisation will shortly be underway. As has been reviewed at the last two ICNCT conferences, the low power of the neuron source and the relatively distant patient position outside the reactor shield led to a column design with certain characteristics. One consequence is the employment of a collimator containing lead of high purity with the resultant problems of mechanical construction. Another is the substantial neutron leakage from the column outside the aperture into the experimental bunker. Furthermore the absence of a gamma shield has led to an electron dose to the skin. This is resolved with an electron shield of aluminium. Here the construction and final design issues are discussed and the state of the project is presented. (author)

  20. Numerical modelling of ozone production in a wire-cylinder corona discharge and comparison with a wire-plate corona discharge

    International Nuclear Information System (INIS)

    Wang Pengxiang; Chen Junhong

    2009-01-01

    The effect of electrode configuration on ozone production in the direct-current corona discharge of dry and humid air is studied by a numerical model that combines the electron distribution in the corona plasma, plasma chemistry and transport phenomena. Two electrode configurations are considered: wire-cylinder discharge with air flowing along the wire axis and wire-plate discharge with air flowing transverse to the wire. The ozone distributions in both types of discharges are compared. For both electrode configurations, the ozone production rate is higher in the negative corona than in the positive corona and it decreases with an increase in relative humidity. More importantly, the detailed ozone distribution in the neighbourhood of the discharge wire, together with the ozone kinetics, reveals the possible difference in the ozone production from the two discharges. With the same operating conditions and sufficiently short flow residence time, the ozone production rate is nearly the same for both electrode configurations. When the flow residence time is longer than the characteristic time for homogeneous ozone destruction, the net ozone production is higher in the wire-cylinder discharge than in the wire-plate discharge due to relatively less ozone destruction.

  1. Numerical modelling of ozone production in a wire-cylinder corona discharge and comparison with a wire-plate corona discharge

    Science.gov (United States)

    Wang, Pengxiang; Chen, Junhong

    2009-02-01

    The effect of electrode configuration on ozone production in the direct-current corona discharge of dry and humid air is studied by a numerical model that combines the electron distribution in the corona plasma, plasma chemistry and transport phenomena. Two electrode configurations are considered: wire-cylinder discharge with air flowing along the wire axis and wire-plate discharge with air flowing transverse to the wire. The ozone distributions in both types of discharges are compared. For both electrode configurations, the ozone production rate is higher in the negative corona than in the positive corona and it decreases with an increase in relative humidity. More importantly, the detailed ozone distribution in the neighbourhood of the discharge wire, together with the ozone kinetics, reveals the possible difference in the ozone production from the two discharges. With the same operating conditions and sufficiently short flow residence time, the ozone production rate is nearly the same for both electrode configurations. When the flow residence time is longer than the characteristic time for homogeneous ozone destruction, the net ozone production is higher in the wire-cylinder discharge than in the wire-plate discharge due to relatively less ozone destruction.

  2. Development of a sealed source radiation detector system for gamma ray scanning of petroleum distillation columns

    International Nuclear Information System (INIS)

    Vasquez Salvador, Pablo Antonio

    2004-01-01

    Gamma Ray Scanning is an online technique to 'view' the hydraulic performance of an operating column, with no disruption to operating processes conditions (pressure and temperature), as a cost-effective solution. The principle of this methodology consists of a small suitably sealed gamma radiation source and a radiation detector experimentally positioned to the column, moving concurrently in small increments on opposite sides and the quantity of gamma transmitted. The source-detector system consists of: a sealed ''6 0 Co radioactive source in a panoramic lead radiator, a scintillator detector coupled to a ratemeter / analyzer and a mobile system. In this work, a gamma scanning sealed source-detector system for distillation columns, was developed, comparing two scintillator detectors: NaI(Tl) (commercial) and CsI(Tl) (IPEN). In order to project the system, a simulated model of a tray-type distillation column was used. The equipment developed was tested in an industrial column for water treatment (6.5 m diameter and 40 m height). The required activities of 6 ''0Co, laboratory (11.1 MBq) and industrial works (1.48 TBq) were calculated by simulation software. Both, the NaI(Tl) and the CsI(Tl) detectors showed good proprieties for gamma scanning applications, determining the position and presence or absence of trays. (author)

  3. Nutrition and HIV-Positive Pregnancy

    OpenAIRE

    Montgomery, Kristen S.

    2003-01-01

    When an HIV-positive woman becomes pregnant, additional nutritional considerations are warranted. Compared to routine prenatal nutritional assessment and intervention, pregnant HIV-positive women have increased needs to promote a healthy outcome. This column contains information on HIV and pregnancy, nutrition and infection, and nutrition for HIV-positive pregnancy. This content can be integrated into childbirth education settings to improve care to women who are HIV-positive.

  4. Confinement and gas fueling in LHD limiter discharges

    International Nuclear Information System (INIS)

    Nishimura, K.; Kawahata, K.; Narihara, K.; Morisaki, T.; Masuzaki, S.; Sakakibara, S.; Tanaka, K.

    2003-01-01

    Plasma discharges in the Large Helical Device are normally open helical divertor discharges. To compare limiter discharges with open divertor discharges and to examine the role of the peripheral region, a radial movable limiter, whose head was made of carbon with high heat conductivity, was inserted into the plasma from the high field side (near the helical coil). The electron temperature was bounded well by the limiter. A high temperature gradient at the edge region was observed in both open divertor and limiter discharges. Formation of such a high temperature gradient led to good energy confinement even in the limiter discharges and an enhancement factor of 1.1±0.3 for International Stellarator Scaling 95 (ISS95) scaling was observed at every limiter position (0.75 ax =3.75 m prevents gas fueling by puffing

  5. Potential of electrical gas discharges for pollution control of large gas volumes

    International Nuclear Information System (INIS)

    Kogelschatz, U.

    1997-01-01

    Non-equilibrium gas discharges in many cases offer an innovative approach to the solution cf industrial air pollution problems. Negative corona discharges are used in electrostatic precipitators to collect dust and fly ash particles. Pulsed positive streamer coronas, dielectric-barrier discharges and possibly also flow-stabilised high pressure glow discharges are emerging technologies for the destruction of air pollutants like nitrogen oxides and sulfur dioxide in flue gases and volatile organic compounds (VOCs) in industrial effluents. The different discharge types are discussed with special emphasis on their potential for upscaling. Major applications are expected particularly in the removal of dilute concentrations of air pollutants, in odour control and in the simultaneous removal of different pollutants. Dielectric-barrier discharges exhibit disposal efficiencies similar to those of pulsed positive streamer coronas and require less sophisticated feeding circuits in large-scale industrial applications. (author)

  6. Performance evaluation of a rectifier column using gamma column scanning

    Directory of Open Access Journals (Sweden)

    Aquino Denis D.

    2017-12-01

    Full Text Available Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.

  7. Single column and two-column H-D-T distillation experiments at TSTA

    International Nuclear Information System (INIS)

    Yamanishi, T.; Yoshida, H.; Hirata, S.; Naito, T.; Naruse, Y.; Sherman, R.H.; Bartlit, J.R.; Anderson, J.L.

    1988-01-01

    Cryogenic distillation experiments were peformed at TSTA with H-D-T system by using a single column and a two-column cascade. In the single column experiment, fundamental engineering data such as the liquid holdup and the HETP were measured under a variety of operational condtions. The liquid holdup in the packed section was about 10 /approximately/ 15% of its superficial volume. The HETP values were from 4 to 6 cm, and increased slightly with the vapor velocity. The reflux ratio had no effect on the HETP. For the wo-colunn experiemnt, dynamic behavior of the cascade was observed. 8 refs., 7 figs., 2 tabs

  8. Nonlinear modulation of ionization waves

    International Nuclear Information System (INIS)

    Bekki, Naoaki

    1981-01-01

    In order to investigate the nonlinear characteristics of ionization waves (moving-striations) in the positive column of glow discharge, a nonlinear modulation of ionization waves in the region of the Pupp critical current is analysed by means of the reductive perturbation method. The modulation of ionization waves is described by a nonlinear Schroedinger type equation. The coefficients of the equation are evaluated using the data of the low pressure Argon-discharge, and the simple solutions (plane wave and envelope soliton type solutions) are presented. Under a certain condition an envelope soliton is propagated through the positive column. (author)

  9. ON THE ORIGIN OF THE HIGH COLUMN DENSITY TURNOVER IN THE H I COLUMN DENSITY DISTRIBUTION

    International Nuclear Information System (INIS)

    Erkal, Denis; Gnedin, Nickolay Y.; Kravtsov, Andrey V.

    2012-01-01

    We study the high column density regime of the H I column density distribution function and argue that there are two distinct features: a turnover at N H I ≈ 10 21 cm –2 , which is present at both z = 0 and z ≈ 3, and a lack of systems above N H I ≈ 10 22 cm –2 at z = 0. Using observations of the column density distribution, we argue that the H I-H 2 transition does not cause the turnover at N H I ≈ 10 21 cm –2 but can plausibly explain the turnover at N H I ∼> 10 22 cm –2 . We compute the H I column density distribution of individual galaxies in the THINGS sample and show that the turnover column density depends only weakly on metallicity. Furthermore, we show that the column density distribution of galaxies, corrected for inclination, is insensitive to the resolution of the H I map or to averaging in radial shells. Our results indicate that the similarity of H I column density distributions at z = 3 and 0 is due to the similarity of the maximum H I surface densities of high-z and low-z disks, set presumably by universal processes that shape properties of the gaseous disks of galaxies. Using fully cosmological simulations, we explore other candidate physical mechanisms that could produce a turnover in the column density distribution. We show that while turbulence within giant molecular clouds cannot affect the damped Lyα column density distribution, stellar feedback can affect it significantly if the feedback is sufficiently effective in removing gas from the central 2-3 kpc of high-redshift galaxies. Finally, we argue that it is meaningful to compare column densities averaged over ∼ kpc scales with those estimated from quasar spectra that probe sub-pc scales due to the steep power spectrum of H I column density fluctuations observed in nearby galaxies.

  10. Adiabatic packed column supercritical fluid chromatography using a dual-zone still-air column heater.

    Science.gov (United States)

    Helmueller, Shawn C; Poe, Donald P; Kaczmarski, Krzysztof

    2018-02-02

    An approach to conducting SFC separations under pseudo-adiabatic condition utilizing a dual-zone column heater is described. The heater allows for efficient separations at low pressures above the critical temperature by imposing a temperature profile along the column wall that closely matches that for isenthalpic expansion of the fluid inside the column. As a result, the efficiency loss associated with the formation of radial temperature gradients in this difficult region can be largely avoided in packed analytical scale columns. For elution of n-octadecylbenzene at 60 °C with 5% methanol modifier and a flow rate of 3 mL/min, a 250 × 4.6-mm column packed with 5-micron Kinetex C18 particles began to lose efficiency (8% decrease in the number of theoretical plates) at outlet pressures below 142 bar in a traditional forced air oven. The corresponding outlet pressure for onset of excess efficiency loss was decreased to 121 bar when the column was operated in a commercial HPLC column heater, and to 104 bar in the new dual-zone heater operated in adiabatic mode, with corresponding increases in the retention factor for n-octadecylbenzene from 2.9 to 6.8 and 14, respectively. This approach allows for increased retention and efficient separations of otherwise weakly retained analytes. Applications are described for rapid SFC separation of an alkylbenzene mixture using a pressure ramp, and isobaric separation of a cannabinoid mixture. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Influence of pressure on the properties of chromatographic columns. II. The column hold-up volume.

    Science.gov (United States)

    Gritti, Fabrice; Martin, Michel; Guiochon, Georges

    2005-04-08

    The effect of the local pressure and of the average column pressure on the hold-up column volume was investigated between 1 and 400 bar, from a theoretical and an experimental point of view. Calculations based upon the elasticity of the solids involved (column wall and packing material) and the compressibility of the liquid phase show that the increase of the column hold-up volume with increasing pressure that is observed is correlated with (in order of decreasing importance): (1) the compressibility of the mobile phase (+1 to 5%); (2) in RPLC, the compressibility of the C18-bonded layer on the surface of the silica (+0.5 to 1%); and (3) the expansion of the column tube (columns packed with the pure Resolve silica (0% carbon), the derivatized Resolve-C18 (10% carbon) and the Symmetry-C18 (20% carbon) adsorbents, using water, methanol, or n-pentane as the mobile phase. These solvents have different compressibilities. However, 1% of the relative increase of the column hold-up volume that was observed when the pressure was raised is not accounted for by the compressibilities of either the solvent or the C18-bonded phase. It is due to the influence of the pressure on the retention behavior of thiourea, the compound used as tracer to measure the hold-up volume.

  12. Compact electron beam focusing column

    Science.gov (United States)

    Persaud, Arun; Leung, Ka-Ngo; Reijonen, Jani

    2001-12-01

    A novel design for an electron beam focusing column has been developed at LBNL. The design is based on a low-energy spread multicusp plasma source which is used as a cathode for electron beam production. The focusing column is 10 mm in length. The electron beam is focused by means of electrostatic fields. The column is designed for a maximum voltage of 50 kV. Simulations of the electron trajectories have been performed by using the 2D simulation code IGUN and EGUN. The electron temperature has also been incorporated into the simulations. The electron beam simulations, column design and fabrication will be discussed in this presentation.

  13. Design and simulation of a 30 kV, 60 kW electron optical column for melting applications

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sachin; Kandaswamy, E.; Bapat, A.V., E-mail: saching@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Electron beam offers unique advantages as a heat source for melting of refractory metals. It provides contamination free homogeneous melting with precise heat control on the melt target. This paper reports the complete electron optics design procedure for a 30 kV, 60 kW melting gun. The design objective of the electron optical column is to obtain the required power density on the target (10{sup 3}-10{sup 4} W/cm{sup 2}) using electrostatic and electromagnetic lenses. The design constrains are to minimize the high voltage discharges in the gun and beam losses in the beam transport. The challenging task of reducing the electrical discharges in the gun during high power melting with the help of twin electromagnetic lenses is presented in the paper. (author)

  14. Nutrition and HIV-Positive Pregnancy

    Science.gov (United States)

    Montgomery, Kristen S.

    2003-01-01

    When an HIV-positive woman becomes pregnant, additional nutritional considerations are warranted. Compared to routine prenatal nutritional assessment and intervention, pregnant HIV-positive women have increased needs to promote a healthy outcome. This column contains information on HIV and pregnancy, nutrition and infection, and nutrition for HIV-positive pregnancy. This content can be integrated into childbirth education settings to improve care to women who are HIV-positive. PMID:17273329

  15. Admittance Scanning for Whole Column Detection.

    Science.gov (United States)

    Stamos, Brian N; Dasgupta, Purnendu K; Ohira, Shin-Ichi

    2017-07-05

    Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 μm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 μm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 μm i.d. column) of 500 μM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

  16. Modeling terrestrial gamma ray flashes produced by relativistic feedback discharges

    Science.gov (United States)

    Liu, Ningyu; Dwyer, Joseph R.

    2013-05-01

    This paper reports a modeling study of terrestrial gamma ray flashes (TGFs) produced by relativistic feedback discharges. Terrestrial gamma ray flashes are intense energetic radiation originating from the Earth's atmosphere that has been observed by spacecraft. They are produced by bremsstrahlung interactions of energetic electrons, known as runaway electrons, with air atoms. An efficient physical mechanism for producing large fluxes of the runaway electrons to make the TGFs is the relativistic feedback discharge, where seed runaway electrons are generated by positrons and X-rays, products of the discharge itself. Once the relativistic feedback discharge becomes self-sustaining, an exponentially increasing number of relativistic electron avalanches propagate through the same high-field region inside the thundercloud until the electric field is partially discharged by the ionization created by the discharge. The modeling results indicate that the durations of the TGF pulses produced by the relativistic feedback discharge vary from tens of microseconds to several milliseconds, encompassing all durations of the TGFs observed so far. In addition, when a sufficiently large potential difference is available in thunderclouds, a self-propagating discharge known as the relativistic feedback streamer can be formed, which propagates like a conventional positive streamer. For the relativistic feedback streamer, the positive feedback mechanism of runaway electron production by the positrons and X-rays plays a similar role as the photoionization for the conventional positive streamer. The simulation results of the relativistic feedback streamer show that a sequence of TGF pulses with varying durations can be produced by the streamer. The relativistic streamer may initially propagate with a pulsed manner and turn into a continuous propagation mode at a later stage. Milliseconds long TGF pulses can be produced by the feedback streamer during its continuous propagation. However

  17. The effects of carbide column to swelling potential and Atterberg limit on expansive soil with column to soil drainage

    Science.gov (United States)

    Muamar Rifa'i, Alfian; Setiawan, Bambang; Djarwanti, Noegroho

    2017-12-01

    The expansive soil is soil that has a potential for swelling-shrinking due to changes in water content. Such behavior can exert enough force on building above to cause damage. The use of columns filled with additives such as Calcium Carbide is done to reduce the negative impact of expansive soil behavior. This study aims to determine the effect of carbide columns on expansive soil. Observations were made on swelling and spreading of carbides in the soil. 7 Carbide columns with 5 cm diameter and 20 cm height were installed into the soil with an inter-column spacing of 8.75 cm. Wetting is done through a pipe at the center of the carbide column for 20 days. Observations were conducted on expansive soil without carbide columns and expansive soil with carbide columns. The results showed that the addition of carbide column could reduce the percentage of swelling by 4.42%. Wetting through the center of the carbide column can help spread the carbide into the soil. The use of carbide columns can also decrease the rate of soil expansivity. After the addition of carbide column, the plasticity index value decreased from 71.76% to 4.3% and the shrinkage index decreased from 95.72% to 9.2%.

  18. Discharge characteristics in inhomogeneous fields under air flow

    DEFF Research Database (Denmark)

    Vogel, Stephan; Holbøll, Joachim

    2017-01-01

    the frequency and magnitude of partial discharges in the vicinity of the electrode due to an increased rate of space charge removal around the tip of the needle and in the gap. The positive polarity shows higher dependency on air flow compared to the negative polarity. It is shown that positive breakdown......This research investigates the impact of high velocity air flow on Partial Discharge (PD) patterns generated in strongly inhomogeneous fields. In the laboratory, a needle plane electrode configuration was exposed to a high electrical DC-field and a laminar air flow up to 22 ms. The needle...

  19. Thermal process of an air column

    International Nuclear Information System (INIS)

    Lee, F.T.

    1994-01-01

    Thermal process of a hot air column is discussed based on laws of thermodynamics. The kinetic motion of the air mass in the column can be used as a power generator. Alternatively, the column can also function as a exhaust/cooler

  20. Gas temperature of capacitance spark discharge in air

    International Nuclear Information System (INIS)

    Ono, Ryo; Nifuku, Masaharu; Fujiwara, Shuzo; Horiguchi, Sadashige; Oda, Tetsuji

    2005-01-01

    Capacitance spark discharge has been widely used for studying the ignition of flammable gas caused by electrostatic discharge. In the present study, the gas temperature of capacitance spark discharge is measured. The gas temperature is an important factor in understanding the electrostatic ignition process because it influences the reaction rate of ignition. Spark discharge is generated in air with a pulse duration shorter than 100 ns. The discharge energy is set to 0.03-1 mJ. The rotational and vibrational temperatures of the N 2 molecule are measured using the emission spectrum of the N 2 second positive system. The rotational and vibrational temperatures are estimated to be 500 and 5000 K, respectively, which are independent of the discharge energy. This result indicates that most of the electron energy is consumed in the excitation of vibrational levels of molecules rather than the heating of the gas. The gas temperature after discharge is also measured by laser-induced fluorescence of OH radicals. It is shown that the gas temperature increases after discharge and reaches approximately 1000 K at 3 μs after discharge. Then the temperature decreases at a rate in the range of 8-35 K/μs depending on the discharge energy

  1. Seasonal dynamics of dissolved, particulate and microbial components of a tidal saltmarsh-dominated estuary under contrasting levels of freshwater discharge

    Science.gov (United States)

    Bittar, Thais B.; Berger, Stella A.; Birsa, Laura M.; Walters, Tina L.; Thompson, Megan E.; Spencer, Robert G. M.; Mann, Elizabeth L.; Stubbins, Aron; Frischer, Marc E.; Brandes, Jay A.

    2016-12-01

    Tidal Spartina-dominated saltmarshes and estuaries on the Southeast US coast are global hotspots of productivity. In coastal Georgia, tidal amplitudes and saltmarsh productivity are the highest along the Southeast US coast. Coastal Georgia is characterized by a humid subtropical seasonal climate, and inter-annual variability in precipitation, and freshwater discharge. The 2012-2013 timeframe encompassed contrasting levels of discharge for the Savannah River, a major Georgia river, with a 4.3-fold greater discharge in summer 2013 relative to summer 2012. In situ measurements of temperature, salinity, precipitation and Secchi depth, and water samples were collected weekly at high tide throughout 2012 and 2013 from the Skidaway River Estuary, a tidal saltmarsh-dominated estuary in coastal Georgia influenced by Savannah River hydrology. The effects of elevated discharge on the seasonal trends of water column components were evaluated. The shift from low discharge (2012) to high discharge (2013) led to decreased salinity in summer 2013, but no significant increases in inorganic nutrient (NH4, NOx, SiO2 and PO4) concentrations. Dissolved inorganic carbon (DIC) concentrations decreased, and DIC stable isotopic signatures (δ13C-DIC values) were depleted in summer 2013 relative to summer 2012. In 2013 dissolved organic carbon (DOC) concentrations, chromophoric and fluorescent dissolved organic matter (DOM: CDOM, FDOM) intensities, specific UV-absorbance (SUVA254) and relative humic-like fluorescence were all higher than in 2012, indicating that, as discharge increased in 2013, estuarine water became enriched in terrigenous DOM. Secchi depth and particulate organic carbon (POC) and nitrogen (PON) concentrations displayed clear seasonal patterns that were not significantly altered by discharge. However, δ13C-POC and δ15N-PON isotopic signatures indicated higher terrigenous contributions at elevated discharge. Discharge influenced cyanobacterial composition, but did not

  2. Solvent extraction columns

    International Nuclear Information System (INIS)

    Middleton, P.; Smith, J.R.

    1979-01-01

    In pulsed columns for use in solvent extraction processes, e.g. the reprocessing of nuclear fuel, the horizontal perforated plates inside the column are separated by interplate spacers manufactured from metallic neutron absorbing material. The spacer may be in the form of a spiral or concentric circles separated by radial limbs, or may be of egg-box construction. Suitable neutron absorbing materials include stainless steel containing boron or gadolinium, hafnium metal or alloys of hafnium. (UK)

  3. Optimal Design of Safety Instrumented Systems for Pressure Control of Methanol Separation Columns in the Bisphenol a Manufacturing Process

    Directory of Open Access Journals (Sweden)

    In-Bok Lee

    2016-12-01

    Full Text Available A bisphenol A production plant possesses considerable potential risks in the top of the methanol separation column, as pressurized acetone, methanol, and water are processed at an elevated temperature, especially in the event of an abnormal pressure increase due to a sudden power outage. This study assesses the potential risks in the methanol separation column through hazard and operability assessments and evaluates the damages in the case of fire and explosion accident scenarios. The study chooses three leakage scenarios: a 5-mm puncture on the methanol separation column, a 50-mm diameter fracture of a discharge pipe and a catastrophic rupture, and, simulated using Phast (Ver. 6.531, the concentration distribution of scattered methanol, thermal radiation distribution of fires, and overpressure distribution of vapor cloud explosions. Implementation of a safety-instrumented system equipped with two-out-of-three voting as a safety measure can detect overpressure at the top of the column and shut down the main control valve and the emergency shutoff valve simultaneously. By applying a safety integrity level of three, the maximal release volume of the safety relief valve can be reduced and, therefore, the design capacity of the flare stack can also be reduced. Such integration will lead to improved safety at a reduced cost.

  4. Experiments with a large sized hollow cathode discharge fed with argon

    International Nuclear Information System (INIS)

    Bastian, C.; Boeschoten, F.; Hekman, H.; Komen, R.; Riske, H.P.; Iersel, A. van.

    1974-04-01

    Several plasma parameters which are pertinent to the rotation of the plasma column of the hollow cathode discharge ''John Luce'' were measured. Several improvements to the device were made, notably concerning the construction of the electrodes and their supports. The ion temperature, Tsub(i), was measured with a Fabry-Perot interferometer; depending on arc current and gas flow Tsub(i) may be varied in argon arc in the range 1-10 eV. The magnetic field strength, B, is adjustable from 600-6000 Gauss. The plasma column is fully ionized, and for higher values of Tsub(i) and B it is also fully magnetized (ωsub(ci)tausub(i) > 1). Simultaneous Doppler-shift measurements of the Asup(II) line 4806 A reveal that the plasma column rotates non-uniformly around its axis. (Order of magnitude of angular frequency is 10 5 rad/sec.) At larger distances from the axis the rotation was measured with a pendulum and with a directional Langmuir Probe. The object of the experiments is to disclose the connection between this rotation and the stability of the plasma column. Langmuir Probes are used to measure radial density profiles under various conditions in the arc. A flat probe with its normal to the surface pointing in radial direction makes reliable ion density measurements possible, even in the presence of a magnetic field. Floating potential measurements were used in order to estimate the radial electric field strength and the drift velocity which is related to it. The electron temperature, Tsub(e), is measured with less accuracy

  5. Nanoparticle formation in H2O/N-2 and H2O/Ar mixtures under irradiation by 20 MeV protons and positive corona discharge

    DEFF Research Database (Denmark)

    Imanaka, M.; Tomita, S.; Kanda, S.

    2010-01-01

    To investigate the contribution of ions to gas nucleation, we have performed experiments on the formation of water droplets in H2O/N-2 and H2O/Ar gas mixtures by irradiation with a 20 MeV proton beam and by positive corona discharge. The size of the formed nanoparticles was measured using...

  6. Impacts of urban wastewater discharge on seagrass meadows ( Zostera noltii)

    Science.gov (United States)

    Cabaço, Susana; Machás, Raquel; Vieira, Vasco; Santos, Rui

    2008-06-01

    The abiotic disturbance of urban wastewater discharge and its effects in the population structure, plant morphology, leaf nutrient content, epiphyte load and macroalgae abundance of Zostera noltii meadows were investigated in Ria Formosa coastal lagoon, southern Portugal using both univariate and multivariate analysis. Four sites were assessed, on a seasonal basis, along a gradient from a major Waste Water Treatment Works (WWTW) discharge to a main navigation channel. The wastewater discharge caused an evident environmental disturbance through the nutrient enrichment of the water and sediment, particularly of ammonium. Zostera noltii of the sites closest to the nutrient source showed higher leaf N content, clearly reflecting the nitrogen load. The anthropogenic nutrient enrichment resulted in higher biomass, and higher leaf and internode length, except for the meadow closest to the wastewater discharge (270 m). The high ammonium concentration (158-663 μM) in the water at this site resulted in the decrease of biomass, and both the leaf and internode length, suggesting a toxic effect on Z. noltii. The higher abundance of macroalgae and epiphytes found in the meadow closest to the nutrient source may also affect the species negatively. Shoot density was higher at the nutrient-undisturbed site. Two of the three abiotic processes revealed by Principal Component Analysis were clearly related to the WWTW discharge, a contrast between water column salinity and nutrient concentration and a sediment contrast between both porewater nutrients and temperature and redox potential. A multiple regression analysis showed that these abiotic processes had a significant effect on the biomass-density dynamics of meadows and on the overall size of Z. noltii plants, respectively. Results show that the wastewater discharge is an important source of environmental disturbance and nutrients availability in Ria Formosa lagoon affecting the population structure, morphology and N content of Z

  7. Magnetic spires for the detection of the position of the plasma column in a Tokamak (linear approximation)

    International Nuclear Information System (INIS)

    Colunga S, S.

    1990-07-01

    In this report the simplified analysis of a method to detect the movement of the plasma column of a tokamak in the vertical direction and of the biggest radius is given. The peculiar case of the Tokamak Novillo of the Plasma Physics Laboratory of the ININ is studied. (Author)

  8. Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lukes, Petr [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic); Clupek, Martin [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic); Babicky, Vaclav [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic); Janda, Vaclav [Department of Water Technology and Environmental Engineering, Institute of Chemical Technology, Technicka 5, 160 28 Prague 6 (Czech Republic); Sunka, Pavel [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic)

    2005-02-07

    Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min{sup -1}), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O{sub 2} mixtures with the maximum efficiency (energy yield) of 23 g kW h{sup -1} for 40% argon content.

  9. Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor

    International Nuclear Information System (INIS)

    Lukes, Petr; Clupek, Martin; Babicky, Vaclav; Janda, Vaclav; Sunka, Pavel

    2005-01-01

    Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min -1 ), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O 2 mixtures with the maximum efficiency (energy yield) of 23 g kW h -1 for 40% argon content

  10. Gaseous carbon dioxide absorbing column

    International Nuclear Information System (INIS)

    Harashina, Heihachi.

    1994-01-01

    The absorbing column of the present invention comprises a cyclone to which CO 2 gas and Ca(OH) 2 are blown to form CaCO 3 , a water supply means connected to an upper portion of the cyclone for forming a thin water membrane on the inner wall thereof, and a water processing means connected to a lower portion of the cyclone for draining water incorporating CaCO 3 . If a mixed fluid of CO 2 gas and Ca(OH) 2 is blown in a state where a flowing water membrane is formed on the inner wall of the cyclone, formation of CaCO 3 is promoted also in the inside of the cyclone in addition to the formation of CaCO 3 in the course of blowing. Then, formed CaCO 3 is discharged from the lower portion of the cyclone together with downwardly flowing water. With such procedures, solid contents such as CaCO 3 separated at the inner circumferential wall are sent into the thin water membrane, adsorbed and captured, and the solid contents are successively washed out, so that a phenomenon that the solid contents deposit and grow on the inner wall of the cyclone can be prevented effectively. (T.M.)

  11. Performance of RC columns with partial length corrosion

    International Nuclear Information System (INIS)

    Wang Xiaohui; Liang Fayun

    2008-01-01

    Experimental and analytical studies on the load capacity of reinforced concrete (RC) columns with partial length corrosion are presented, where only a fraction of the column length was corroded. Twelve simply supported columns were eccentrically loaded. The primary variables were partial length corrosion in tensile or compressive zone and the corrosion level within this length. The failure of the corroded column occurs in the partial length, mainly developed from or located nearby or merged with the longitudinal corrosion cracks. For RC column with large eccentricity, load capacity of the column is mainly influenced by the partial length corrosion in tensile zone; while for RC column with small eccentricity, load capacity of the column greatly decreases due to the partial length corrosion in compressive zone. The destruction of the longitudinally mechanical integrality of the column in the partial length leads to this great reduction of the load capacity of the RC column

  12. Stability of position control system in JIPP T-II

    International Nuclear Information System (INIS)

    Sakurai, Keiichi; Tanahashi, Shygo

    1980-01-01

    Computations and experiments on the stability of a feedback control system for maintaining a plasma column in equilibrium are described. The time response of the displacement of the plasma to the desired position is examined by solving the equation of motion of the plasma column. We show that the stability of the feedback control system is improved by using an additional term which represents the shift velocity of the plasma column. (author)

  13. Efficiency of ozone production by pulsed positive corona discharge in synthetic air

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan; Člupek, Martin

    2002-01-01

    Roč. 35, č. 11 (2002), s. 1171-1175 ISSN 0022-3727 R&D Projects: GA AV ČR IAA1043102; GA ČR GA202/99/1298 Institutional research plan: CEZ:AV0Z2043910 Keywords : corona, synthetic air Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.366, year: 2002

  14. Residual dust charges in discharge afterglow

    International Nuclear Information System (INIS)

    Coueedel, L.; Mikikian, M.; Boufendi, L.; Samarian, A. A.

    2006-01-01

    An on-ground measurement of dust-particle residual charges in the afterglow of a dusty plasma was performed in a rf discharge. An upward thermophoretic force was used to balance the gravitational force. It was found that positively charged, negatively charged, and neutral dust particles coexisted for more than 1 min after the discharge was switched off. The mean residual charge for 200-nm-radius particles was measured. The dust particle mean charge is about -5e at a pressure of 1.2 mbar and about -3e at a pressure of 0.4 mbar

  15. 29 CFR 1926.755 - Column anchorage.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Column anchorage. 1926.755 Section 1926.755 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.755 Column anchorage. (a) General requirements for erection stability. (1) All columns shall be anchored by a minimum of 4 anchor...

  16. Adsorption columns for use in radioimmunoassays

    International Nuclear Information System (INIS)

    1976-01-01

    Adsorption columns are provided which can be utilized in radioimmunoassay systems such as those involving the separation of antibody-antigen complexes from free antigens. The preparation of the columns includes the treatment of retaining substrate material to render it hydrophilic, preparation and degassing of the separation material and loading the column

  17. An analysis of five negative sprite-parent discharges and their associated thunderstorm charge structures

    Science.gov (United States)

    Boggs, Levi D.; Liu, Ningyu; Splitt, Michael; Lazarus, Steven; Glenn, Chad; Rassoul, Hamid; Cummer, Steven A.

    2016-01-01

    In this study we analyze the discharge morphologies of five confirmed negative sprite-parent discharges and the associated charge structures of the thunderstorms that produced them. The negative sprite-parent lightning took place in two thunderstorms that were associated with a tropical disturbance in east central and south Florida. The first thunderstorm, which moved onshore in east central Florida, produced four of the five negative sprite-parent discharges within a period of 17 min, as it made landfall from the Atlantic Ocean. These negative sprite-parents were composed of bolt-from-the-blue (BFB), hybrid intracloud-negative cloud-to-ground (IC-NCG), and multicell IC-NCGs discharges. The second thunderstorm, which occurred inland over south Florida, produced a negative sprite-parent that was a probable hybrid IC-NCG discharge and two negative gigantic jets (GJs). Weakened upper positive charge with very large midlevel negative charge was inferred for both convective cells that initiated the negative-sprite-parent discharges. Our study suggests tall, intense convective systems with high wind shear at the middle to upper regions of the cloud accompanied by low cloud-to-ground (CG) flash rates promote these charge structures. The excess amount of midlevel negative charge results in these CG discharges transferring much more charge to ground than typical negative CG discharges. We find that BFB discharges prefer an asymmetrical charge structure that brings the negative leader exiting the upper positive charge region closer to the lateral positive screening charge layer. This may be the main factor in determining whether a negative leader exiting the upper positive region of the thundercloud forms a BFB or GJ.

  18. Atmospheric pressure helium afterglow discharge detector for gas chromatography

    Science.gov (United States)

    Rice, Gary; D'Silva, Arthur P.; Fassel, Velmer A.

    1986-05-06

    An apparatus for providing a simple, low-frequency electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.

  19. NMFS Water Column Sonar Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water column sonar data are an important component of fishery independent surveys, habitat studies and other research. NMFS water column sonar data are archived here.

  20. Properties of dielectric barrier discharges in different arrangements

    International Nuclear Information System (INIS)

    Pietsch, G.J.

    2001-01-01

    Dielectric barrier discharges (DBDs) occur in arrangements where at least one dielectric is positioned in a gas space in between conducting electrodes. When breakdown field strength is reached in such a device, charge carriers are created in the gas region, accelerated, multiplied and finally collected on the surface(s) of the dielectric(s). The charge accumulation on the dielectric creates a counter field to that resulting from the power supply and as all of these processes are rather fast, the discharge quenches rapidly. The dielectric has two tasks, it limits the transferred charge and by this the energy conversion and distributes the discharge over the electrode area. That is why DBDs are non-thermal discharges which exist even at atmospheric pressure

  1. HPLC analysis of o-, m- and p-isomers using a betacyclodextrin column

    International Nuclear Information System (INIS)

    Haeger, J.

    1994-01-01

    The irradiation of foodstuffs containing protein leads to the hydroxylation of phenylalanine, due to which the position isomers o-tyrosine and m-tyrosine are formed in addition to the naturally occurring p-tyrosine. HPLC analysis of tyrosine isomers following sample processing and purification is generally carried out in a RP-C 18 column. In actual practice, the peaks of p-tyrosine and m-tyrosine overlap and a separation of o-tyrosine from baseline cannot always be achieved. Those separation problems may be solved, if a beta-cyclodextrin column is used in addition or as an alternative to the RP-C 18 column. The completely different separation characteristics of the latter provide a new pattern of elution for the tyrosine isomers. It is thus possible for p-tyrosine, which occurs in much higher concentrations than the other tyrosines, to be clearly separated chromatographically. (orig./vhe) [de

  2. Investigating the Effect of Column Geometry on Separation Efficiency using 3D Printed Liquid Chromatographic Columns Containing Polymer Monolithic Phases.

    Science.gov (United States)

    Gupta, Vipul; Beirne, Stephen; Nesterenko, Pavel N; Paull, Brett

    2018-01-16

    Effect of column geometry on the liquid chromatographic separations using 3D printed liquid chromatographic columns with in-column polymerized monoliths has been studied. Three different liquid chromatographic columns were designed and 3D printed in titanium as 2D serpentine, 3D spiral, and 3D serpentine columns, of equal length and i.d. Successful in-column thermal polymerization of mechanically stable poly(BuMA-co-EDMA) monoliths was achieved within each design without any significant structural differences between phases. Van Deemter plots indicated higher efficiencies for the 3D serpentine chromatographic columns with higher aspect ratio turns at higher linear velocities and smaller analysis times as compared to their counterpart columns with lower aspect ratio turns. Computational fluid dynamic simulations of a basic monolithic structure indicated 44%, 90%, 100%, and 118% higher flow through narrow channels in the curved monolithic configuration as compared to the straight monolithic configuration at linear velocities of 1, 2.5, 5, and 10 mm s -1 , respectively. Isocratic RPLC separations with the 3D serpentine column resulted in an average 23% and 245% (8 solutes) increase in the number of theoretical plates as compared to the 3D spiral and 2D serpentine columns, respectively. Gradient RPLC separations with the 3D serpentine column resulted in an average 15% and 82% (8 solutes) increase in the peak capacity as compared to the 3D spiral and 2D serpentine columns, respectively. Use of the 3D serpentine column at a higher flow rate, as compared to the 3D spiral column, provided a 58% reduction in the analysis time and 74% increase in the peak capacity for the isocratic separations of the small molecules and the gradient separations of proteins, respectively.

  3. Evaluation of Packed Distillation Columns I - Atmospheric Pressure

    National Research Council Canada - National Science Library

    Reynolds, Thaine

    1951-01-01

    .... Four column-packing combinations of the glass columns and four column-packing combinations of the steel columns were investigated at atmospheric pressure using a test mixture of methylcyclohexane...

  4. Center column design of the PLT

    International Nuclear Information System (INIS)

    Citrolo, J.; Frankenberg, J.

    1975-01-01

    The center column of the PLT machine is a secondary support member for the toroidal field coils. Its purpose is to decrease the bending moment at the nose of the coils. The center column design was to have been a stainless steel casting with the toroidal field coils grouped around the casting at installation, trapping it in place. However, the castings developed cracks during fabrication and were unsuitable for use. Installation of the coils proceeded without the center column. It then became necessary to redesign a center column which would be capable of installation with the toroidal field coils in place. The final design consists of three A-286 forgings. This paper discusses the final center column design and the influence that new knowledge, obtained during the power tests, had on the new design

  5. The handedness of historiated spiral columns.

    Science.gov (United States)

    Couzin, Robert

    2017-09-01

    Trajan's Column in Rome (AD 113) was the model for a modest number of other spiral columns decorated with figural, narrative imagery from antiquity to the present day. Most of these wind upwards to the right, often with a congruent spiral staircase within. A brief introductory consideration of antique screw direction in mechanical devices and fluted columns suggests that the former may have been affected by the handedness of designers and the latter by a preference for symmetry. However, for the historiated columns that are the main focus of this article, the determining factor was likely script direction. The manner in which this operated is considered, as well as competing mechanisms that might explain exceptions. A related phenomenon is the reversal of the spiral in a non-trivial number of reproductions of the antique columns, from Roman coinage to Renaissance and baroque drawings and engravings. Finally, the consistent inattention in academic literature to the spiral direction of historiated columns and the repeated publication of erroneous earlier reproductions warrants further consideration.

  6. Column-oriented database management systems

    OpenAIRE

    Možina, David

    2013-01-01

    In the following thesis I will present column-oriented database. Among other things, I will answer on a question why there is a need for a column-oriented database. In recent years there have been a lot of attention regarding a column-oriented database, even if the existence of a columnar database management systems dates back in the early seventies of the last century. I will compare both systems for a database management – a colum-oriented database system and a row-oriented database system ...

  7. Radiotracer Imaging of Sediment Columns

    Science.gov (United States)

    Moses, W. W.; O'Neil, J. P.; Boutchko, R.; Nico, P. S.; Druhan, J. L.; Vandehey, N. T.

    2010-12-01

    Nuclear medical PET and SPECT cameras routinely image radioactivity concentration of gamma ray emitting isotopes (PET - 511 keV; SPECT - 75-300 keV). We have used nuclear medical imaging technology to study contaminant transport in sediment columns. Specifically, we use Tc-99m (T1/2 = 6 h, Eγ = 140 keV) and a SPECT camera to image the bacteria mediated reduction of pertechnetate, [Tc(VII)O4]- + Fe(II) → Tc(IV)O2 + Fe(III). A 45 mL bolus of Tc-99m (32 mCi) labeled sodium pertechnetate was infused into a column (35cm x 10cm Ø) containing uranium-contaminated subsurface sediment from the Rifle, CO site. A flow rate of 1.25 ml/min of artificial groundwater was maintained in the column. Using a GE Millennium VG camera, we imaged the column for 12 hours, acquiring 44 frames. As the microbes in the sediment were inactive, we expected most of the iron to be Fe(III). The images were consistent with this hypothesis, and the Tc-99m pertechnetate acted like a conservative tracer. Virtually no binding of the Tc-99m was observed, and while the bolus of activity propagated fairly uniformly through the column, some inhomogeneity attributed to sediment packing was observed. We expect that after augmentation by acetate, the bacteria will metabolically reduce Fe(III) to Fe(II), leading to significant Tc-99m binding. Imaging sediment columns using nuclear medicine techniques has many attractive features. Trace quantities of the radiolabeled compounds are used (micro- to nano- molar) and the half-lives of many of these tracers are short (Image of Tc-99m distribution in a column containing Rifle sediment at four times.

  8. Hg+ ion density in low-pressure Ar-Hg discharge plasma used for liquid crystal display back-lighting

    International Nuclear Information System (INIS)

    Goto, Miki; Arai, Toshihiko

    1995-01-01

    The positive column of a low-pressure Ar-Hg discharge has been applied as a fluorescent light source for illumination. Many studies on the diagnostics and fundamental mechanisms have been carried out on both the classical fluorescent lamp (d=36 mm) and the compact fluorescent lamp (d=12 mm). On the other hand, a lamp of extremely narrow diameter (usually below 6 mm) has been recently developed for liquid crystal display (LCD) back-lighting and its importance is undoubtedly increasing. Some characteristics or mechanisms of the narrow-diameter lamp may be similar to those of the 36 mm one; however the similarity rule does not hold between them due to the contributions from a stepwise ionization process. Therefore, in order to clarify the excitation mechanism in the narrow-diameter lamp quantitatively, various parameters must be measured directly and some analysis must be done. The Hg + ion density and electron density are important parameters for the purpose of clarifying the excitation mechanism quantitatively. In this work, we have measured the Hg + ion density using the modified absorption method, and the electron density using the probe method in the Ar-Hg discharge of the 4 mm bore tube on bath temperature. Moreover, with combining the modified absorption method and the probe method, the Hg 2 + molecular ion density has been determined

  9. Thermally stable dexsil-400 glass capillary columns

    International Nuclear Information System (INIS)

    Maskarinec, M.P.; Olerich, G.

    1980-01-01

    The factors affecting efficiency, thermal stability, and reproducibility of Dexsil-400 glass capillary columns for gas chromatography in general, and for polycyclic aromatic hydrocarbons (PAHs) in particular were investigated. Columns were drawn from Kimble KG-6 (soda-lime) glass or Kimox (borosilicate) glass. All silylation was carried out at 200 0 C. Columns were coated according to the static method. Freshly prepared, degassed solutions of Dexsil-400 in pentane or methylene chloride were used. Thermal stability of the Dexsil 400 columns with respect to gas chromatography/mass spectrometry (GC/MS) were tested. Column-to-column variability is a function of each step in the fabrication of the columns. The degree of etching, extent of silylation, and stationary phase film thickness must be carefully controlled. The variability in two Dexsil-400 capillary column prepared by etching, silylation with solution of hexa methyl disilazone (HMDS), and static coating is shown and also indicates the excellent selectivity of Dexsil-400 for the separation of alkylated aromatic compounds. The wide temperature range of Dexsil-400 and the high efficiency of the capillary columns also allow the analysis of complex mixtures with minimal prefractionation. Direct injection of a coal liquefaction product is given. Analysis by GC/MS indicated the presence of parent PAHs, alkylated PAHs, nitrogen and sulfur heterocycles, and their alkylated derivatives. 4 figures

  10. Pancreatitis - discharge

    Science.gov (United States)

    Chronic pancreatitis - discharge; Pancreatitis - chronic - discharge; Pancreatic insufficiency - discharge; Acute pancreatitis - discharge ... You were in the hospital because you have pancreatitis. This is a swelling of the pancreas. You ...

  11. Study on Gas-liquid Falling Film Flow in Internal Heat Integrated Distillation Column

    Science.gov (United States)

    Liu, Chong

    2017-10-01

    Gas-liquid internally heat integrated distillation column falling film flow with nonlinear characteristics, study on gas liquid falling film flow regulation control law, can reduce emissions of the distillation column, and it can improve the quality of products. According to the distribution of gas-liquid mass balance internally heat integrated distillation column independent region, distribution model of heat transfer coefficient of building internal heat integrated distillation tower is obtained liquid distillation falling film flow in the saturated vapour pressure of liquid water balance, using heat transfer equation and energy equation to balance the relationship between the circulating iterative gas-liquid falling film flow area, flow parameter information, at a given temperature, pressure conditions, gas-liquid flow falling film theory makes the optimal parameters to achieve the best fitting value with the measured values. The results show that the geometric gas-liquid internally heat integrated distillation column falling film flow heat exchange area and import column thermostat, the average temperature has significant. The positive correlation between the heat exchanger tube entrance due to temperature difference between inside and outside, the heat flux is larger, with the increase of internal heat integrated distillation column temperature, the slope decreases its temperature rise, which accurately describes the internal gas-liquid heat integrated distillation tower falling film flow regularity, take appropriate measures to promote the enhancement of heat transfer. It can enhance the overall efficiency of the heat exchanger.

  12. Electrical and spectroscopic characterization of a surgical argon plasma discharge

    International Nuclear Information System (INIS)

    Keller, Sandra; Neugebauer, Alexander; Bibinov, Nikita; Awakowicz, Peter

    2013-01-01

    For electrosurgical procedures, the argon plasma coagulation (APC) discharge is a well-established atmospheric-pressure plasma tool for thermal haemostasis and devitalization of biological tissue. To characterize this plasma source, voltage-current measurements, microphotography, optical emission spectroscopy and numerical simulation are applied. Two discharge modes are established during the operation of the APC plasma source. A short transient spark discharge is ignited within the positive half period of the applied high voltage after a streamer channel connects the APC probe and the counter-electrode. During the second phase, which continues under negative high voltage, a glow discharge is stabilized in the plasma channel.

  13. Safety barriers and lighting columns.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1972-01-01

    Problems arising from the sitting of lighting columns on the central reserve are reviewed, and remedial measures such as break-away lighting supports and installation of safety fences on the central reserve on both sides of the lighting columns are examined.

  14. Stratification of living organisms in ballast tanks: how do organism concentrations vary as ballast water is discharged?

    Science.gov (United States)

    First, Matthew R; Robbins-Wamsley, Stephanie H; Riley, Scott C; Moser, Cameron S; Smith, George E; Tamburri, Mario N; Drake, Lisa A

    2013-05-07

    Vertical migrations of living organisms and settling of particle-attached organisms lead to uneven distributions of biota at different depths in the water column. In ballast tanks, heterogeneity could lead to different population estimates depending on the portion of the discharge sampled. For example, concentrations of organisms exceeding a discharge standard may not be detected if sampling occurs during periods of the discharge when concentrations are low. To determine the degree of stratification, water from ballast tanks was sampled at two experimental facilities as the tanks were drained after water was held for 1 or 5 days. Living organisms ≥50 μm were counted in discrete segments of the drain (e.g., the first 20 min of the drain operation, the second 20 min interval, etc.), thus representing different strata in the tank. In 1 and 5 day trials at both facilities, concentrations of organisms varied among drain segments, and the patterns of stratification varied among replicate trials. From numerical simulations, the optimal sampling strategy for stratified tanks is to collect multiple time-integrated samples spaced relatively evenly throughout the discharge event.

  15. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  16. ''Relaxing phenomena'' in negative corona discharge in air: new aspects

    International Nuclear Information System (INIS)

    Strelle, D.; Pavlik, M.; Skalny, J.D.

    1998-01-01

    Several conspicuous differences between the positive and the negative corona discharges in air observed in small discharge gaps have been explained by two recent theoretical models considering the ion-molecule and chemical reactions in the negative corona discharge in air. In the present paper the discrepancies of these models are discussed, and the earlier experimental data and the presumptions used in the models are re-examined in the light of the latest experimentally confirmed facts. (J.U.)

  17. Transport and survival of Cryptosporidium parvum oocysts in soil columns following applications of raw and separated liquid slurry

    DEFF Research Database (Denmark)

    Petersen, Heidi H.; Enemark, Heidi; Olsen, Annette

    The widespread waterborne pathogen Cryptosporidium parvum is frequently transmitted to humans via contaminated drinking and recreational water. Nearly all drinking water in Denmark is groundwater, which can be contaminated with oocysts e.g. from application of contaminated manure to the field...... in the leachates from soil columns to which Cryptosporidium positive slurry had been injected. Although recovery rates were low, regardless of slurry type, C. parvum oocysts were detected from all soil columns. Variations in the leachate patterns were recorded between soil columns added raw and liquid slurry...

  18. Transport and survival of Cryptosporidium Parvum Oocysts in Soil Columns Following Applications of Raw and Separated Liquid Slurry

    DEFF Research Database (Denmark)

    Petersen, H.H.; Enemark, Heidi L.; Olsen, A.

    The widespread waterborne pathogen Cryptosporidium parvum is primarily transmitted to humans via contaminated drinking and recreational water. Nearly all drinking water in Denmark is groundwater, but this can be contaminated with oocysts from application of contaminated manure to the field. Oocysts...... in the leachates from soil columns to which Cryptosporidium positive slurry had been injected. Although recovery rates were low, regardless of slurry type, C. parvum oocysts were detected from all soil columns. Variations in the leachate patterns were recorded between soil columns added raw and liquid slurry...

  19. Heat Transfer Analysis for a Fixed CST Column

    International Nuclear Information System (INIS)

    Lee, S.Y.

    2004-01-01

    In support of a small column ion exchange (SCIX) process for the Savannah River Site waste processing program, a transient two-dimensional heat transfer model that includes the conduction process neglecting the convection cooling mechanism inside the crystalline silicotitanate (CST) column has been constructed and heat transfer calculations made for the present design configurations. For this situation, a no process flow condition through the column was assumed as one of the reference conditions for the simulation of a loss-of-flow accident. A series of the modeling calculations has been performed using a computational heat transfer approach. Results for the baseline model indicate that transit times to reach 130 degrees Celsius maximum temperature of the CST-salt solution column are about 96 hours when the 20-in CST column with 300 Ci/liter heat generation source and 25 degrees Celsius initial column temperature is cooled by natural convection of external air as a primary heat transfer mechanism. The modeling results for the 28-in column equipped with water jacket systems on the external wall surface of the column and water coolant pipe at the center of the CST column demonstrate that the column loaded with 300 Ci/liter heat source can be maintained non-boiling indefinitely. Sensitivity calculations for several alternate column sizes, heat loads of the packed column, engineered cooling systems, and various ambient conditions at the exterior wall of the column have been performed under the reference conditions of the CST-salt solution to assess the impact of those parameters on the peak temperatures of the packed column for a given transient time. The results indicate that a water-coolant pipe at the center of the CST column filled with salt solution is the most effective one among the potential design parameters related to the thermal energy dissipation of decay heat load. It is noted that the cooling mechanism at the wall boundary of the column has significant

  20. Impurity studies and discharge cleaning in Doublet III

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, F.B.

    1979-10-01

    The goal of present and next generation tokamak experiments is to produce high-density, high-purity plasmas during high-power, extended-duration discharges. Plasma discharges with Z/sub eff/ values near unity and low concentrations of medium and high-Z metallic impurities have been obtained in Doublet III using a combination of low-power hydrogen discharge cleaning, gas puffing, precise plasma shape and position control, and high-Z limiters. Analysis of the first wall surface and residual gas impurities confirmed that clean conditions have been achieved. The high-Z limiters showed very limited amounts of melting or arcing. The progress of the wall cleaning process was monitored by three diagnostic techniques: Auger electron spectroscopy of metallic samples at the vessel wall, residual gas analysis, and the resistivity of full power discharges.

  1. Impurity studies and discharge cleaning in Doublet III

    International Nuclear Information System (INIS)

    Marcus, F.B.

    1979-10-01

    The goal of present and next generation tokamak experiments is to produce high-density, high-purity plasmas during high-power, extended-duration discharges. Plasma discharges with Z/sub eff/ values near unity and low concentrations of medium and high-Z metallic impurities have been obtained in Doublet III using a combination of low-power hydrogen discharge cleaning, gas puffing, precise plasma shape and position control, and high-Z limiters. Analysis of the first wall surface and residual gas impurities confirmed that clean conditions have been achieved. The high-Z limiters showed very limited amounts of melting or arcing. The progress of the wall cleaning process was monitored by three diagnostic techniques: Auger electron spectroscopy of metallic samples at the vessel wall, residual gas analysis, and the resistivity of full power discharges

  2. NON-LINEAR ANALYSIS OF AN EXPERIMENTAL JOINT OF COLUMN AND BEAMS OF ARMED CONCRETE-STEEL COLUMN FOR FRAME

    Directory of Open Access Journals (Sweden)

    Nelson López

    2017-12-01

    Full Text Available In this research, the nonlinear behavior of a real-scale experimental joint (node is studied, consisting of three reinforced concrete elements, one column and two beams joined to a structural steel column at the upper level. In the numerical analysis the model of the union was analyzed in the inelastic range, this model was elaborated with the finite element program based on fibers, SeismoStruct to analyze as a function of time, the traction and compression efforts in the confined area and not confined area of the concrete column and in the longitudinal reinforcement steel, as well as verification of the design of the base plate that joins the two columns. The results showed that tensile stresses in the unconfined zone surpassed the concrete breaking point, with cracking occurring just below the lower edge of the beams; in the confined area the traction efforts were much lower, with cracks occurring later than in the non-confined area. The concrete column-steel column joint behaved as a rigid node, so the elastic design was consistent with the calculation methodology of base plates for steel columns.

  3. Heart pacemaker - discharge

    Science.gov (United States)

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  4. Tracing submarine groundwater discharge in the NE Gulf of Mexico by 222Rn

    International Nuclear Information System (INIS)

    Young, J.E.; Burnett, W.C.; Chanton, J.P.; Cable, P.H.; Corbett, D.R.

    1993-01-01

    Inputs of freshwater and dissolved components to the ocean by submarine groundwater discharge (SGD) have been largely neglected as source functions for biogeochemical budgets. In order to locate and quantify groundwater inputs, a tracing technique has been developed using 222 Rn, a member of the natural 238 U decay-series. Because 222 Rn has a short half-life (t 1/2 = 3.84 days), is an inert gas, is relatively easy to measure at low concentrations, and has concentrations in groundwater several orders of magnitude greater than seawater, it should make an excellent tracer. Excess 222 Rn concentrations far above ''normal'' ocean values were found in the bottom waters of the northeastern Gulf of Mexico, which suggests this region has significant groundwater discharge. After measuring high water column inventories of excess 222 Rn in this region, an advection/diffusion model was applied to evaluate potential benthic sources of radon. The model is designed to account for sediment diffusion of radon and includes a groundwater term for advective flow into the overlying water. Flow rates and concentrations are adjusted in the model to balance the large difference in the measured water column inventories and the inventory predicted by sediment diffusion alone. The vertical diffusive/advective transport determines the shape of the concentration gradient and fluxes at the sediment-water interface are calculate based on these terms. The authors work shows that SGD could account for as much as 95% of the radon inventory in these offshore waters

  5. Fabrication of a micrometer Ni–Cu alloy column coupled with a Cu micro-column for thermal measurement

    International Nuclear Information System (INIS)

    Lin, J C; Chang, T K; Yang, J H; Jeng, J H; Lee, D L; Jiang, S B

    2009-01-01

    Micrometer Ni–Cu alloy columns have been fabricated by the micro-anode-guided electroplating (MAGE) process in the citrate bath. The surface morphology and chemical composition of the micro-columns were determined by copper concentration in the bath and by the electrical bias of MAGE. When fabricated in a bath of dilute copper (i.e. 4 mM) at lower voltages (e.g. 3.8 and 4.0 V), the alloy micro-columns revealed uniform diameter and smooth appearance. The alloy composition demonstrated an increase in the wt% ratio of Ni/Cu from 75/25, 80/20, 83/17 to 87/13 with increasing electrical bias from 3.8, 4.0, 4.2 to 4.4 V. However, it decreases from 75/25, 57/43 to 47/53 with increasing copper concentration from 4, 8 to 12 mM in the bath. Citrate plays a role in forming complexes with nickel and copper at similar reduction potentials, thus reducing simultaneously to Ni–Cu alloy. The mechanism for fabricating alloy micro-columns could be delineated on the basis of cathodic polarization of the complexes. A couple of micro-columns were fabricated using MAGE in constructing a pure copper micro-column on the top of a Ni/Cu (at 47/53) alloy micro-column. This micro-thermocouple provides a satisfactory measurement with good sensitivity and precision

  6. Double layers in a modestly collisional electronegative discharge

    CERN Document Server

    Sheridan, T E

    1999-01-01

    The effect of ion-neutral collisions on the structure and ion flux emanating from a steady-state, planar discharge with two negative components is investigated. The positive ion component is modelled as a cold fluid subject to constant-mobility collisions, while the electrons and negative ions obey Boltzmann relations. The model includes the collisionless limit. When the negative ions are sufficiently cold three types of discharge structures are found. For small negative ion concentrations or high collisionality, the discharge is 'stratified', with an electronegative core and an electropositive edge. For the opposite conditions, the discharge is 'uniform' with the negative ion density remaining significant at the edge of the plasma. Between these cases lies the special case of a double-layer-stratified discharge, where quasi-neutrality is violated at the edge of the electronegative core. Double-layer-stratified solutions are robust in that they persist for moderate collisionality. Numerical solutions for fini...

  7. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  8. Time-Resolved Fourier Transform Emission Spectroscopy of He/CH4 in a Positive Column Discharge

    Czech Academy of Sciences Publication Activity Database

    Civiš, Svatopluk; Kubelík, Petr; Ferus, Martin

    2012-01-01

    Roč. 116, č. 12 (2012), s. 3137-3147 ISSN 1089-5639 R&D Projects: GA AV ČR IAA400400705; GA AV ČR IAAX00100903; GA ČR GAP208/10/2302 Institutional research plan: CEZ:AV0Z40400503; CEZ:AV0Z10100523 Keywords : infrared-laser spectroscopy * high-temperature pyrolysis * amorphous-carbon films Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.771, year: 2012

  9. Behavior of reinforced concrete columns strenghtened by partial jacketing

    Directory of Open Access Journals (Sweden)

    D. B. FERREIRA

    Full Text Available This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column e PR (reference column. The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.

  10. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  11. Large gap plasma display cell with auxiliary electrodes: macro-cell experiments and two-dimensional modelling

    International Nuclear Information System (INIS)

    Ouyang, J T; Callegari, Th; Caillier, B; Boeuf, J-P

    2003-01-01

    In this paper we use a two-dimensional fluid model and a 'macroscopic' PDP cell to investigate the possibility of using large gap configurations with auxiliary electrodes to improve the efficiency of PDP discharge cells. The large gap allows operation in a transient positive column regime where energy is more efficiently deposited into xenon excitation, while the auxiliary electrodes are used to keep reasonable values of the operating voltage. Two types of auxiliary electrode configurations (floating and powered) are considered. The discharge characteristics and the discharge efficiency in exciting xenon are studied with simulations and by measuring the intensity of infrared emission from xenon and visible emission from neon in a macroscopic PDP cell. The results show that an efficient positive column regime can be achieved at reasonably low operating voltages when the auxiliary electrode configuration is carefully designed

  12. Chromatographic properties PLOT multicapillary columns.

    Science.gov (United States)

    Nikolaeva, O A; Patrushev, Y V; Sidelnikov, V N

    2017-03-10

    Multicapillary columns (MCCs) for gas chromatography make it possible to perform high-speed analysis of the mixtures of gaseous and volatile substances at a relatively large amount of the loaded sample. The study was performed using PLOT MCCs for gas-solid chromatography (GSC) with different stationary phases (SP) based on alumina, silica and poly-(1-trimethylsilyl-1-propyne) (PTMSP) polymer as well as porous polymers divinylbenzene-styrene (DVB-St), divinylbenzene-vinylimidazole (DVB-VIm) and divinylbenzene-ethylene glycol dimethacrylate (DVB-EGD). These MCCs have the efficiency of 4000-10000 theoretical plates per meter (TP/m) and at a column length of 25-30cm can separate within 10-20s multicomponent mixtures of substances belonging to different classes of chemical compounds. The sample amount not overloading the column is 0.03-1μg and depends on the features of a porous layer. Examples of separations on some of the studied columns are considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A narrative analysis positioning HIV relative to personal (sexual) relationship challenges in an agony aunt column in the Western Cape, South Africa - Aunty Mona's "love advice".

    Science.gov (United States)

    Viljoen, Lario; Thorne, Marguerite; Thomas, Angelique; Bond, Virginia; Hoddinott, Graeme

    2016-01-01

    HIV prevalence and incidence in South Africa remain high, making HIV a part of everyday life. Community narratives on HIV treatment and prevention are important and influence official and unofficial health messaging and community perceptions and understandings of HIV. We explore how contributors and the columnist of an agony aunt column position HIV relative to choices made about love, partnership, and sex over three years. We analysed all columns of an agony aunt series (Antie Mona) published between December 2012 and November 2015. The column is published in a South African, Afrikaans-language newspaper "Son", prioritising sensationalist news items. Trends were identified through narrative analysis. Data were managed in ATLAS.ti and inductive, iterative coding conducted. It was found that letters to the agony aunt rarely refer to HIV directly (less than 7%). Euphemisms such as diseases of the flesh and the great flu were more commonly used instead of HIV or AIDS. Letters addressed HIV in three ways: direct references to experiences living with HIV; direct questions about HIV prevention; and scenarios where HIV could (from a public health perspective) have been the main concern, but everyday issues took precedence. The majority of letters fell into this latter category where the writers focused on the immediate concerns of good sexual relations, problems related to love and romantic relationships, good moral behaviour of others, and issues of oppressive life conditions rather than on HIV directly. The findings illustrate that informal, public contributions to health information, such as agony aunts, are important narratives that inform popular perspectives on HIV and health. A better appreciation of this context would allow health implementers to ensure that these role players receive updated health messaging to avoid the risk of HIV-related stigma where HIV is used as a moral rod to punish perceived moral transgressions.

  14. Dynamic characteristics of corona discharge generated under rainfall condition on AC charged conductors

    Science.gov (United States)

    Xu, Pengfei; Zhang, Bo; Wang, Zezhong; Chen, Shuiming; He, Jinliang

    2017-12-01

    By synchronous measurement of corona current and the water droplet deformation process on a conductor surface, different types of corona discharge are visualized when AC voltage is applied on a line-ground electrode system. The corona characteristics are closely related to the applied voltage and water supply rate. With the increase of AC voltage, the positive Taylor cone discharge firstly appears and then disappears, replaced by the dripping and crashing discharge. Furthermore, the number of pulses in each pulse train increases with the increase of applied voltage. The mechanism of the transfer from the positive Taylor cone discharge to the dripping and crashing discharge is found to be related to the oscillation process of the water droplet. The water supply rate also has a great influence on the characteristics of corona currents. The number of positive pulse trains increases linearly when the water supply rate gets larger, leading to a higher audible noise and radio interference level from the AC corona, which is quite different from that of the DC corona. The difference between the AC and DC coronas under rainfall conditions is analyzed finally.

  15. Distribution of biochemical constituents in the surface sediments of western coastal Bay of Bengal: Influence of river discharge and water column properties

    Digital Repository Service at National Institute of Oceanography (India)

    Kumar, B.S.K.; Sarma, V.V.S.S.; Krishna, M.S.

    region characterized by low nutrients suspended particulate matter (SPM), high phytoplankton biomass in the water column and high SOC while contrasting to that observed in the SW region. The isotopic ratios of SOC (-22 ppt) in the NW region were close...

  16. Characteristics of pulse corona discharge over water surface

    Science.gov (United States)

    Fujii, Tomio; Arao, Yasushi; Rea, Massimo

    2008-12-01

    Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water was waved by corona wind. The positive streamer corona showed more ozone production than the negative one both in the DC and in the pulse corona.

  17. Characteristics of pulse corona discharge over water surface

    International Nuclear Information System (INIS)

    Fujii, Tomio; Arao, Yasushi; Rea, Massimo

    2008-01-01

    Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO 2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water was waved by corona wind. The positive streamer corona showed more ozone production than the negative one both in the DC and in the pulse corona.

  18. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  19. Investigations of electropositive and electronegative RF discharges

    International Nuclear Information System (INIS)

    Bryant, P.M.

    2000-01-01

    Electronegative RF discharges are extensively used in the semi-conductor industry for material processing. Despite this the subject of electronegative RF discharges has been largely neglected. The aim of this thesis is to investigate a RF oxygen discharge by mass/energy spectrometry, a retarding field analyser and an actively compensated Langmuir probe. Measurements are also obtained in argon for comparison. In this thesis pure oxygen will be used as this has relatively simple discharge chemistry with most of the rate constants well known. Ion energy analysis (Chapter 3) show the discharge to contract into the centre of the chamber at low pressures in both gases. The expected thinner peak of the oxygen ion energy distribution was not observed, this is shown to be due to RF modulation of the positive ions with collisions playing a role. The dominant positive ion in the discharge bulk and colliding in the sheath in oxygen was found to be O 2 + with less than 10% O + over the range of pressure investigated (Chapter 4). Various minor ions such as O 3 + and O 4 + were also observed. By actively compensating a Langmuir probe for the first three plasma harmonics it is shown that it is unnecessary to compensate when the amplitude of a given harmonic is comparable to the electron temperature (Chapter 5). A study of Langmuir probe measurements in argon (Chapter 7) has shown that the use of the collisionless Alien, Boyd and Reynolds theory leads to discrepancies in the measured electron densities. The correct density can be obtained by using the perturbation method of Shih and Levi, this corrects for ion-neutral collisions in electropositive plasmas only. This theory is extended to electronegative plasmas (Chapter 6) so that measurements of the negative ion density obtained from the collisionless theory of Arnemiya, Annaratone and Alien can be corrected. Langmuir probe measurements in oxygen indicate a peak in the negative ion density at around 3Pa and are found to be in good

  20. Measurement of Mo-99 column activity in the evaluation of Mo-99/Tc-99m generator

    International Nuclear Information System (INIS)

    Kuster, Z.

    1994-01-01

    In order to calculate the real elution efficiency of Mo-99/Tc-99m generator the Mo-99 content on the column has to be previously determined. As found in this work, the external measurement of Mo-99-column activity by means of Geiger-Mueller counter is a simple, fast and reliable method. Generally, Mo-99-column is placed slightly out of the center of the generator; therefore the externally measured flux of photons (φ) is an angular-dependent function. If the thickness of the lead container is radially uniform, the flux measured at some distance from the generator (which is rotated in 2π/3 steps) is given by the equation φ = A (1 + Bcos (α-2π(i - 2)/3)) -1 , i=1,2 or 3 (Eq.1) where A is a numerical constant depending on the Mo-99-column activity, B is a numerical constant depending on the Mo-99- column position within the lead container, the angle α depends on the initial orientation of the generator. A total of 20 generator were studied. The measured Mo-99-column activities (Capintec dose calibrator) were in the range 13.1- 35.11 GBq. Contrary to the findings of Vinberg and Kristensen (Eur J Nucl Med 1/1976(219), values of A (Eq. 1) are in good correlation (r 2 =0.9794) with the measured Mo-99-column activities. (author)

  1. PRTR ion exchange vault column sampling

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1995-01-01

    This report documents ion exchange column sampling and Non Destructive Assay (NDA) results from activities in 1994, for the Plutonium Recycle Test Reactor (PRTR) ion exchange vault. The objective was to obtain sufficient information to prepare disposal documentation for the ion exchange columns found in the PRTR Ion exchange vault. This activity also allowed for the monitoring of the liquid level in the lower vault. The sampling activity contained five separate activities: (1) Sampling an ion exchange column and analyzing the ion exchange media for purpose of waste disposal; (2) Gamma and neutron NDA testing on ion exchange columns located in the upper vault; (3) Lower vault liquid level measurement; (4) Radiological survey of the upper vault; and (5) Secure the vault pending waste disposal

  2. Critical analysis of partial discharge dynamics in air filled spherical voids

    Science.gov (United States)

    Callender, G.; Golosnoy, I. O.; Rapisarda, P.; Lewin, P. L.

    2018-03-01

    In this paper partial discharge (PD) is investigated inside a spherical air filled void at atmospheric pressure using a drift diffusion model. Discharge dynamics consisted of an electron avalanche transitioning into positive streamer, in agreement with earlier work on dielectric barrier discharges. Different model configurations were utilised to test many of the concepts employed in semi-analytical PD activity models, which use simplistic descriptions of the discharge dynamics. The results showed that many of these concepts may be erroneous, with significant discrepancies between the canonical reasoning and the simulation results. For example, the residual electric field, the electric field after a discharge, is significantly lower than the estimates used by classical PD activity models in the literature.

  3. Control of plasma layer in a fusion reactor correlated to DC motor control using PSO-ANFIS

    International Nuclear Information System (INIS)

    Mahapatra, Sakuntala; Daniel, Raju; Dey, Deep Narayan

    2013-01-01

    Plasma position and shape control is very crucial for the overall performance of the fusion reactor such as Tokamak. The quality of the discharge in the Saskatchewan TORus-Modified (STOR-M) tokamak is strongly related to the position of the plasma column within the discharge vessel. If the plasma column approaches too near the wall, then either minor or complete disruption occurs. Consequently it is necessary to be able to control dynamically the position of the plasma column throughout the entire discharge. Now a day's most fusion reactor employs the traditional PID controller for the confinement of plasma layer. Fuzzy logic is used for the control of Plasma layer. In this paper we have used the hybrid of PSO-ANFIS technique to control the speed of a DC motor. We have used two input parameters like speed, torque and output is firing angle. In our work first order Sugeno fuzzy model is taken with three rules and the parameters of Gaussian membership function is controlled by the PSO technique. PSO-ANFIS speed controller obtains better dynamic behavior and superior performance of the DC motor speed control. Similar approach can be correlated to the control of plasma layer. For the plasma control two inputs can be taken as plasma position ΔH and the plasma current and the single output, the control decision u(t). (author)

  4. Double discharges in unipolar-pulsed dielectric barrier discharge xenon excimer lamps

    International Nuclear Information System (INIS)

    Liu Shuhai; Neiger, Manfred

    2003-01-01

    Excitation of dielectric barrier discharge xenon excimer lamps by unipolar short square pulses is studied in this paper. Two discharges with different polarity are excited by each voltage pulse (double discharge phenomenon). The primary discharge occurs at the top or at the rising flank of the applied unipolar square pulse, which is directly energized by the external circuit. The secondary discharge with the reversed polarity occurs at the falling flank or shortly after the falling flank end (zero external voltage) depending on the pulse width, which is energized by the energy stored by memory charges deposited by the primary discharge. Fast-speed ICCD imaging shows the primary discharge has a conic discharge appearance with a channel broadening on the anode side. This channel broadening increases with increasing the pulse top level. Only the anode-side surface discharge is observed in the primary discharge. The surface discharge on the cathode side which is present in bipolar sine voltage excitation is not observed. On the contrary, the secondary discharge has only the cathode-side surface discharge. The surface discharge on the anode side is not observed. The secondary discharge is much more diffuse than the primary discharge. Time-resolved emission measurement of double discharges show the secondary discharge emits more VUV xenon excimer radiation but less infrared (IR) xenon atomic emission than the primary discharge. It was found that the IR xenon atomic emission from the secondary discharge can be reduced by shortening the pulse width. The energy efficiency of unipolar-pulsed xenon excimer lamps (the overall energy efficiency of double discharges) is much higher than that obtained under bipolar sine wave excitation. The output VUV spectrum under unipolar pulse excitation is found to be identical to that under sine wave excitation and independent of injected electric power

  5. Effect of finite conductivity on the vertical stability of a tokamak plasma column with a noncircular cross section without conducting shell

    International Nuclear Information System (INIS)

    Sakurai, Keiichi; Okuda, Takayoshi; Tanaka, Yuji.

    1977-01-01

    The effect of finite conductivity on the stability of a tokamak plasma column with noncircular cross section without conducting shell was investigated by considering the current filaments model. The study is made for the plasma with rectangular cross section, and in this case, the position control of plasma column is a serious problem. The equation of motion of the plasma column is described for the vertical force applied to the column. The calculation of stability was made for the cases with cross sections of circular, rectangular and D type shapes. The plasma column was considered as an assembly of a lot of circular conductors, and this method can be applied to the plasma column with proper distribution of conductivity. As the results of calculation, it can be said that the electromotive force produced by the column moving in the magnetic field generates surface current on the plasma column, and in case of the finite conductivity of plasma, this current attenuates with time, and the distribution of the current soaks into the plasma column. Consequently, the recovery force acting on the plasma column is reduced, but contributes to the vertical stabilization for several hundreds μsec. (Kato, T.)

  6. Liquid conductor model of instabilities in a pinched discharge

    Energy Technology Data Exchange (ETDEWEB)

    Dattnery, A; Lehnert, B [Dept. of Electronics, Royal Institute of Technology, Stockholm (Sweden); Lundquist, S [Swedish State Power Board (Sweden)

    1958-07-01

    The pinched gas discharge experiments seem to have been handicapped by the great speed with which the instability develops as well as by the light coming from impurities instead of the main body of pinched gas. In the present work a liquid conductor is used in order to study the structure of the instabilities. The study of a pinch was made with and without the axial magnetic field. In cases with a magnetic field, the currents and fields were chosen so as to give a longitudinal magnetic field equal to or three times the azimuthal field at the boundary of the mercury stream. The study of the results shows that in the case without an external magnetic field there is a similarity between the behavior of the pinch in a stream of mercury and in an ionized gas column. The stabilizing action of the surface tension is small and the instabilities develop easily. The case with an external magnetic field is more complicated. The magnetic lines of force are not frozen into the medium; they can 'escape' from the medium. In this case the magnetic field has no stabilizing effect. The influence of conducting walls around the mercury column will be studied in forthcoming experiments.

  7. Laser surface wakefield in a plasma column

    International Nuclear Information System (INIS)

    Gorbunov, L.M.; Mora, P.; Ramazashvili, R.R.

    2003-01-01

    The structure of the wakefield in a plasma column, produced by a short intense laser pulse, propagating through a gas affected by tunneling ionization is investigated. It is shown that besides the usual plasma waves in the bulk part of the plasma column [see Andreev et al., Phys. Plasmas 9, 3999 (2002)], the laser pulse also generates electromagnetic surface waves propagating along the column boundary. The length of the surface wake wave substantially exceeds the length of the plasma wake wave and its electromagnetic field extends far outside the plasma column

  8. [Study on Square Super-Lattice Pattern with Surface Discharge in Dielectric Barrier Discharge by Optical Emission Spectra].

    Science.gov (United States)

    Niu, Xue-jiao; Dong, Li-fang; Liu, Ying; Wang, Qian; Feng, Jian-yu

    2016-02-01

    Square super-lattice pattern with surface discharge consisting of central spots and dim spots is firstly observed in the mixture of argon and air by using a dielectric barrier discharge device with water electrodes. By observing the image, it is found that the central spot is located at the centriod of its surrounding four dim spots. The short-exposure image recorded by a high speed video camera shows that the dim spot results from the surface discharges (SDs). The brightness of the central spot and is quite different from that of the dim spot, which indicates that the plasma states of the central spot and the dim spot may be differentiated. The optical emission spectrum method is used to further study the several plasma parameters of the central spot and the dim spot in different argon content. The emission spectra of the N₂ second positive band (C³IIu --> B³ IIg) are measured, from which the molecule vibration temperatures of the central spot and the dim spot are calculated respectively. The broadening of spectral line 696.57 nm (2P₂-->1S₅) is used to study the electron densities of the central spot and the dim spot. It is found that the molecule vibration temperature and electron density of the dim spot are higher than those of the central spot in the same argon content The molecule vibration temperature and electron density of the central spot and the dim spot increase with the argon content increasing from 90% to 99.9%. The surface discharge induced by the volume discharge (VD) has the determinative effect on the formation of the dim spot The experimental results above play an important role in studying the formation mechanism of surface discharg&of square super-lattice pattern with surface discharge. In addition, the studies exert an influence on the application of surface discharge and volume discharge in different fields.

  9. Field Applications of Gamma Column Scanning Technology

    International Nuclear Information System (INIS)

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  10. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M., E-mail: anacamiqui@gmail.com, E-mail: egoncalves@con.ufrj.br, E-mail: brandao@ien.gov.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  11. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    International Nuclear Information System (INIS)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M.

    2017-01-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  12. Semi-analytical modelling of positive corona discharge in air

    Science.gov (United States)

    Pontiga, Francisco; Yanallah, Khelifa; Chen, Junhong

    2013-09-01

    Semianalytical approximate solutions of the spatial distribution of electric field and electron and ion densities have been obtained by solving Poisson's equations and the continuity equations for the charged species along the Laplacian field lines. The need to iterate for the correct value of space charge on the corona electrode has been eliminated by using the corona current distribution over the grounded plane derived by Deutsch, which predicts a cos m θ law similar to Warburg's law. Based on the results of the approximated model, a parametric study of the influence of gas pressure, the corona wire radius, and the inter-electrode wire-plate separation has been carried out. Also, the approximate solutions of the electron number density has been combined with a simplified plasma chemistry model in order to compute the ozone density generated by the corona discharge in the presence of a gas flow. This work was supported by the Consejeria de Innovacion, Ciencia y Empresa (Junta de Andalucia) and by the Ministerio de Ciencia e Innovacion, Spain, within the European Regional Development Fund contracts FQM-4983 and FIS2011-25161.

  13. Anomalous electrical signals associated with microbial activity: Results from Iron and Nitrate-Reducing Columns

    Science.gov (United States)

    Aaron, R. B.; Zheng, Q.; Flynn, P.; Singha, K.; Brantley, S.

    2008-12-01

    /m), increased in the iron reducing column (0.2 S/m to 0.8 S/m) and increased markedly in the nitrate reducing column (0.3 S/m to 1.2 S/m). This runs counter to our expectations. We expected to see an increase in σ b as [Fe(II)] increased and a decrease in σ b as nitrate was removed from the columns. All three columns showed little or no IP response at the outset and developed negative chargeabilities over the course of the experiment (as great as -20 mV/V). These values are anomalous and difficult to interpret. SP signals show the most variable response. Initially all three columns had SP values at or very near 0 mV. SP for the nitrate reducing column remained constant around 0mV. The iron reducing column displayed an increasingly negative SP response for the first two months that became constant at about -200mV for the remainder of the experiment. The alternating redox column displayed an oscillating signal recording large positive values (~475 mV) when nitrate concentrations were low and returning to a baseline value (~160mV) when nitrate was introduced to the column. The results of these column experiments indicate that there is a link between microbial activity and geophysical signals and that further research is needed to better quantify these signals.

  14. Characteristics of a corona discharge with a hot corona electrode

    International Nuclear Information System (INIS)

    Kulumbaev, E. B.; Lelevkin, V. M.; Niyazaliev, I. A.; Tokarev, A. V.

    2011-01-01

    The effect of the temperature of the corona electrode on the electrical characteristics of a corona discharge was studied experimentally. A modified Townsend formula for the current-voltage characteristic of a one-dimensional corona is proposed. Gasdynamic and thermal characteristics of a positive corona discharge in a coaxial electrode system are calculated. The calculated results are compared with the experimental data.

  15. Development of a short pulsed corona discharge ionization source for ion mobility spectrometry

    International Nuclear Information System (INIS)

    An Yuan; Aliaga-Rossel, R.; Choi, Peter; Gilles, Jean-Paul

    2005-01-01

    The development of a pulsed corona discharge ionization source and its use in ion mobility spectrometry (IMS) is presented. In a point-plane electrode geometry, an electrical pulse up to 12 kV, 150 ns rise time and 500 ns pulse width was used to generate a corona discharge in air. A single positive high voltage pulse was able to generate about 1.6x10 10 ions at energy consumption of 22 μJ. Since the temporal distribution of ions is in a pulsed form, the possibility of removal the ion gate has been investigated. By purposely arranging the interface between discharge field and drift field, nearly 10 7 positive ions were drawn into the drift region with absence of the ion gate after every single discharge. The positive spectrum of acetone dimer (working at room temperature) was obtained with a resolving power of 20 by using this configuration. The advantages of this new scheme are the low power consumption compared with the dc method as well as the simplicity of the IMS cell structure

  16. Preparation and characterization of micro-cell membrane chromatographic column with N-hydroxysuccinimide group-modified silica-based porous layer open tubular capillary.

    Science.gov (United States)

    Xu, Liang; Xu, Bei; Zhao, Zhi-Yu; Yang, Hui-Ping; Tang, Cheng; Dong, Lin-Yi; Liu, Kun; Fu, Li; Wang, Xian-Hua

    2017-09-22

    Cell membrane chromatography (CMC) is an effective tool in screening active compounds from natural products and studying membrane protein interactions. Nevertheless, it always consumes a large amount of cells (e.g. 10 7 -10 8 ) for column preparation. To overcome this, micro-CMC (mCMC), that employs a silica capillary as membrane carrier, was developed. However, both CMC and mCMC suffer from short column life span (e.g. 3days), mainly due to the falling-off of cellular membranes (CMs). This has greatly limited further application of CMC and mCMC, especially when the cells are hard to obtain. To solve this, N-hydroxysuccinimide (NHS)-modified silica-based porous layer open tubular capillary was first prepared for mCMC. The NHS groups can easily react with amino groups on CMs to form a stable covalent bond under a mild condition. So, CMs immobilized on the NHS-modified capillary are less likely to fall off. To verify this, SKBR3/mCMC (Her2 positive) and BALL1/mCMC (CD20 positive) columns were prepared. Two monoclonal antibody drugs, trastuzumab (anti-Her2) and rituximab (anti-CD20), were selected as analytes to characterize the columns. As a result, NHS-modified column for mCMC can afford higher chromatographic retention than non-modified column. Besides, the column life span was significantly improved to more than 16days for SKBR3/mCMC and 14days for BALL1/mCMC, while the compared column showed a sharp decline in retention factor in first 3days. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Picobubble enhanced column flotation of fine coal

    Energy Technology Data Exchange (ETDEWEB)

    Tao, D.; Yu, S.; Parekh, B.K. [University of Kentucky, Lexington, KY (United States). Mining Engineering

    2006-07-01

    The purpose is to study the effectiveness of picobubbles in the column flotation of -28 mesh fine coal particles. A flotation column with a picobubble generator was developed and tested for enhancing the recovery of ultrafine coal particles. The picobubble generator was designed using the hydrodynamic cavitation principle. A metallurgical and a steam coal were tested in the apparatus. The results show that the use of picobubbles in a 2in. flotation column increased the recovery of fine coal by 10 to 30%. The recovery rate varied with feed rate, collector dosage, and other column conditions. 40 refs., 8 figs., 2 tabs.

  18. Polarization of X-ray lines emitted from plasma-focus discharges; Problems of interpretation

    International Nuclear Information System (INIS)

    Jakubowski, L.

    2002-01-01

    In high current pulse discharges of the Plasma Focus (PF) type, inside the collapsing pinch column, there are formed local micro-regions of high-density and high-temperature plasma, so-called hot spots. Individual hot spots are separated in space and time. Each hot spot is characterized by its specific electron concentration and temperature, as well as by the emission of X-ray lines with different polarization. When numerous hot spots are produced it is impossible to determine local plasma parameters and to interpret the polarization effects. To eliminate this problem this study was devoted to the realization of PF-type discharges with single hot spot only. It has been achieved by a choice of the electrode configuration, which facilitated the formation of a single hot spot emitting intense X-ray lines. At the chosen experimental conditions it was possible to determine local plasma parameters and to demonstrate evident differences in the polarization of the observed X-ray lines. (author)

  19. Polarization of x-ray lines emitted from plasma-focus discharges; Problems of interpretation

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M.J.; Baronova, E.O.

    2003-01-01

    In high current pulse discharges of the Plasma Focus (PF) type, inside the collapsing pinch column, there are formed local micro-regions of high-density and high-temperature plasma, so-called hot spots. Individual hot spots are separated in space and time. Each hot spot is characterized by its specific electron concentration and temperature, as well as by the emission of X-ray lines with different polarization. When numerous hot spots are produced it is impossible to determine local plasma parameters and to interpretate the polarization effects. To eliminate this problem this study was devoted to the realization of PF-type discharges with single hot spot only. It has been achieved by a choice of the electrode configuration, which facilitated the formation of a single hot spot emitting intense X-ray lines. At the chosen experimental conditions it was possible to determine local plasma parameters and to demonstrate evident differences in the polarization of the observed X-ray lines. (author)

  20. Transport of copper as affected by titania nanoparticles in soil columns

    Energy Technology Data Exchange (ETDEWEB)

    Fang Jing [School of Environmental Science and Engineering, Zhejiang Gongshang University, Hangzhou 310012 (China); Shan Xiaoquan, E-mail: xiaoquan@rcees.ac.cn [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Wen Bei [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Lin Jinming [Department of Chemistry, Tsinghua University, Beijing 100084 (China); Owens, Gary [Centre for Environmental Risk Assessment and Remediation, University of South Australia, Mawson Lakes, SA 5095 (Australia); Zhou Shuairen [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)

    2011-05-15

    The effects of TiO{sub 2} nanoparticles on the transport of Cu through four different soil columns were studied. For two soils (HB and DX), TiO{sub 2} nanoparticles acted as a Cu carrier and facilitated the transport of Cu. For a third soil (BJ) TiO{sub 2} nanoparticles also facilitated Cu transport but to a much lesser degree, but for a fourth soil (HLJ) TiO{sub 2} nanoparticles retarded the transport of Cu. Linear correlation analysis indicated that soil properties rather than sorption capacities for Cu primary governed whether TiO{sub 2} nanoparticles-facilitated Cu transport. The TiO{sub 2}-associated Cu of outflow in the Cu-contaminated soil columns was significantly positively correlated with soil pH and negatively correlated with CEC and DOC. During passage through the soil columns 46.6-99.9% of Cu initially adsorbed onto TiO{sub 2} could be 'stripped' from nanoparticles depending on soil, where Cu desorption from TiO{sub 2} nanoparticles increased with decreasing flow velocity and soil pH. - Highlights: > TiO{sub 2} nanoparticles could facilitate or retard the transport of Cu in soils. > Soil properties primarily governed TiO{sub 2}-facilitated Cu transport. > Cu initially adsorbed onto TiO{sub 2} could be 'stripped' duing transport. - TiO{sub 2} nanoparticles play an important role in mediating and transporting Cu in soil columns.

  1. Exploring the effect of mesopore size reduction on the column performance of silica-based open tubular capillary columns.

    Science.gov (United States)

    Hara, Takeshi; Futagami, Shunta; De Malsche, Wim; Baron, Gino V; Desmet, Gert

    2018-06-01

    We report on a modification in the hydrothermal treatment process of monolithic silica layers used in porous-layered open tubular (PLOT) columns. Lowering the temperature from the customary 95 °C to 80 °C, the size of the mesopores reduced by approximately about 35% from 12-13.5 nm to 7.5-9 nm, while the specific pore volume essentially remains unaltered. This led to an increase of the specific surface area (SA) of about 40%, quasi-independent of the porous layer thickness. The increased surface area provided a corresponding increase in retention, somewhat more (48%) than expected based on the increase in SA for the thin layer columns, and somewhat less than expected (34%) for the thick layer columns. The recipes were applied in 5 μm i.d.-capillaries with a length of 60 cm. Efficiencies under retained conditions amounted up to N = 137,000 for the PLOT column with a layer thickness (d f ) of 300 nm and to N = 109,000 for the PLOT column with d f  = 550 nm. Working under conditions of similar retention, the narrow pore/high SA columns produced with the new 80 °C recipe generated the same number of theoretical plates as the wide pore size/low SA columns produced with the 95 °C recipe. This shows the 80 °C-hydrothermal treatment process allows for an increase in the phase ratio of the PLOT columns without affecting their intrinsic mass transfer properties and separation kinetics. This is further corroborated by the fact that the plate height curves generated with the new and former recipe can both be well-fitted with the Golay-Aris equation without having to change the intra-layer diffusion coefficient. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Galactography: the diagnostic procedure of choice for nipple discharge

    International Nuclear Information System (INIS)

    Tabar, L.; Dean, P.B.; Pentek, Z.

    1983-01-01

    Galactogrpahy was performed in 204 women with a nipple discharge and the secretion confirmed histopathologically. All 116 intraductal tumors (papilloma, papillomatosis, carcinoma), which were associated with a serous or bloody discharge, were detected preoperatively. A palpable mass had little diagnostic significance, and exfoliative cytology was positive in only 11% (2/18) of the patients with carcinoma. The authors recommend that all patients with a spontaneous bloody or serous discharge from a single lactiferous orifice undergo galactography in addition to physical, cytological, and mammographic examination. Intraductal injection of methylene blue dye will demonstrate the affected duct system to the surgeon and can often make surgery less radical or even unnecessary

  3. Modelling of a plasma column sustained by a travelling circularly polarized electromagnetic wave (m=1 mode) in the presence of a constant axial magnetic field

    International Nuclear Information System (INIS)

    Benova, E.; Staikov, P.; Zhelyazkov, I.

    1992-01-01

    A set of equations modelling a low-pressure plasma column sustained by a travelling electromagnetic wave in the dipolar mode in the presence of a constant external magnetic field is presented. It is shown that, from a practical point of view, only the m = 1 mode (the right-hand-polarized wave) can sustain plasma columns in a wide region of gas-discharge conditions: plasma radius R, wave frequency ω, magnetic field B 0 and low pressures, irrespective of the nature of the gas. The main result of this study is that the magnetic field makes it possible to sustain a plasma column for values of σ smaller than σ cr = 0.3726, below which, in the absence of a magnetic field, the dipolar wave cannot produce a plasma. Moreover, at a fixed wave power, the magnetic field - in contrast with the case of plasma columns sustained by azimuthally symmetric waves - increases the plasma density and its axial gradient. The limit of an infinite external magnetic field (Ω → ∞) is also considered. A three-dimensional wave structure is obtained, and it indicates that the wave can be a generalized surface mode, a pure surface or a pseudosurface one. (author)

  4. Discharge Characteristics of the Nickel Hydroxide Electrode in 30% KOH

    International Nuclear Information System (INIS)

    Kim, Young Jin

    1989-01-01

    The discharge behavior of the nickel hydroxide electrode has been investigated in 30% KOH at 25 .deg. C. Two voltage plateaus are displayed on the discharge curve of C/20. It is shown that the impedance of the nickel hydroxide electrode increases with decrease of the discharge potential. The discharge behavior of the nickel hydroxide electrode has been investigated in 30% KOH indicating the reduction of the β-NiOOH to the β-Ni(OH) 2 by proton diffusion process and hence the electronic conductivity change of the nickel hydroxide electrode. Furthermore, the γ-NiOOH, produced by prolonged oxidation of the β-NiOOH in 30% KOH, discharges at a slightly lower potential than the β-Ni(OH) 2 that could result in the life-limiting factor of several alkaline electrolyte storage batteries using the nickel hydroxide electrode as the positive plate

  5. [Online enrichment ability of restricted-access column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride].

    Science.gov (United States)

    Zhang, Xiaohui; Wang, Rong; Xie, Hua; Yin, Qiang; Li, Xiaoyun; Jia, Zhengping; Wu, Xiaoyu; Zhang, Juanhong; Li, Wenbin

    2013-05-01

    The online enrichment ability of the restricted-access media (RAM) column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride in plasma was studied. The RAM-HPLC system consisted of an RAM column as enrichment column and a C18 column as analytical column coupled via the column switching technique. The effects of the injection volume on the peak area and the systematic pressure were studied. When the injection volume was less than 100 microL, the peak area increased with the increase of the injection volume. However, when the injection volume was more than 80 microL, the pressure of whole system increased obviously. In order to protect the whole system, 80 microL was chosen as the maximum injection volume. The peak areas of ordinary injection and the large volume injection showed a good linear relationship. The enrichment ability of RAM-HPLC system was satisfactory. The system was successfully used for the separation and detection of the trace benazepril hydrochloride in rat plasma after its administration. The sensitivity of HPLC can be improved by RAM pre-enrichment. It is a simple and economic measurement method.

  6. Dynamics of dielectric barrier discharges in different arrangements

    International Nuclear Information System (INIS)

    Gibalov, Valentin I; Pietsch, Gerhard J

    2012-01-01

    Based on experimental results, numerical investigations of dielectric barrier discharges (DBDs) have been performed in three basic configurations: in the volume, coplanar and surface discharge arrangements. It is shown that the DBD dynamics is the same in all arrangements and it is determined by the development of a few principal constituents, i.e. cathode- and anode-directed streamers, discharge channel, cathode layer and surface charges. It is found that the anode- and cathode-directed streamers appear with a highly conductive channel in between. The interaction of the streamers with conductive and dielectric surfaces determines the filamentary or homogeneous appearance of the discharge and its properties. The cathode-directed streamer is a self-sustaining phenomenon, which moves in a gas gap or along an electrode driven by a positive loop-back between photoemission and electron multiplication. The anode-directed streamer plays a subsidiary role. Depending on the kind of gas (electronegative or electropositive) and/or the degree of development of the cathode-directed streamer, the field strength in the conductive channels changes significantly. When the cathode-directed streamer touches the electrode surface, a cathode layer appears with parameters close to those of normal glow discharges. In volume discharge arrangements the movement of the streamers results in the appearance of Lichtenberg figures on dielectric surfaces. (paper)

  7. Response of steel box columns in fire conditions

    Directory of Open Access Journals (Sweden)

    Mahmood Yahyai

    2017-05-01

    Full Text Available Effect of elevated temperatures on the mechanical properties of steel, brings the importance of investigating the effect of fire on the steel structures anxiously. Columns, as the main load-carrying part of a structure, can be highly vulnerable to the fire. In this study, the behavior of steel gravity columns with box cross section exposed to fire has been investigated. These kinds of columns are widely used in common steel structures design in Iran. In current study, the behavior of such columns in fire conditions is investigated through the finite element method. To perform this, the finite element model of a steel column which has been previously tested under fire condition, was prepared. Experimental loading and boundary conditions were considered in the model and was analyzed. Results were validated by experimental data and various specimens of gravity box columns were designed according to the Iran’s steel buildings code, and modeled and analyzed using Abaqus software. The effect of width to thickness ratio of column plates, the load ratio and slenderness on the ultimate strength of the column was investigated, and the endurance time was estimated under ISO 834 standard fire curve. The results revealed that an increase in width to thickness ratio and load ratio leads to reduction of endurance time and the effect of width to thickness ratio on the ultimate strength of the column decreases with temperature increase.

  8. Ductility of reinforced concrete columns confined with stapled strips

    International Nuclear Information System (INIS)

    Tahir, M.F.; Khan, Q.U.Z.; Shabbir, F.; Sharif, M.B.; Ijaz, N.

    2015-01-01

    Response of three 150x150x450mm short reinforced concrete (RC) columns confined with different types of confining steel was investigated. Standard stirrups, strips and stapled strips, each having same cross-sectional area, were employed as confining steel around four comer column bars. Experimental work was aimed at probing into the affect of stapled strip confinement on post elastic behavior and ductility level under cyclic axial load. Ductility ratios, strength enhancement factor and core concrete strengths were compared to study the affect of confinement. Results indicate that strength enhancement in RC columns due to strip and stapled strip confinement was not remarkable as compared to stirrup confined column. It was found that as compared to stirrup confined column, stapled strip confinement enhanced the ductility of RC column by 183% and observed axial capacity of stapled strip confined columns was 41 % higher than the strip confined columns. (author)

  9. Retrofit of distillation columns in biodiesel production plants

    International Nuclear Information System (INIS)

    Nguyen, Nghi; Demirel, Yasar

    2010-01-01

    Column grand composite curves and the exergy loss profiles produced by the Column-Targeting Tool of the Aspen Plus simulator are used to assess the performance of the existing distillation columns, and reduce the costs of operation by appropriate retrofits in a biodiesel production plant. Effectiveness of the retrofits is assessed by means of thermodynamics and economic improvements. We have considered a biodiesel plant utilizing three distillation columns to purify biodiesel (fatty acid methyl ester) and byproduct glycerol as well as reduce the waste. The assessments of the base case simulation have indicated the need for modifications for the distillation columns. For column T202, the retrofits consisting of a feed preheating and reflux ratio modification have reduced the total exergy loss by 47%, while T301 and T302 columns exergy losses decreased by 61% and 52%, respectively. After the retrofits, the overall exergy loss for the three columns has decreased from 7491.86 kW to 3627.97 kW. The retrofits required a fixed capital cost of approximately $239,900 and saved approximately $1,900,000/year worth of electricity. The retrofits have reduced the consumption of energy considerably, and leaded to a more environmentally friendly operation for the biodiesel plant considered.

  10. Studies of low current back-discharge in point-plane geometry with dielectric layer

    International Nuclear Information System (INIS)

    Jaworek, A.; Rajch, E.; Czech, T.; Lackowski, M

    2005-01-01

    The paper presents results of spectroscopic investigations of back-discharge generated in the point-plane electrode geometry in air at atmospheric pressure, with the plane covered with fly ash layer. Four forms of the discharges were studied: onset streamers, glow, breakdown streamers and low-current back-arc discharge. Both polarities of the active discharge electrode, positive and negative, were tested. The back discharge is a type of DC electrical discharge, which take place when the passive plane electrode is covered with a dielectric layer. The layer can be made of solid material or a packed bed of dust or powder of low conductivity. The charge produced due to ionisation processes in the vicinity of the active point electrode is accumulated on the dielectric surface, and generates high electric field through this layer. When critical electric field through the layer is attained an electrical breakdown of the layer take place. The point of breakdown becomes a new source of ions of polarity opposite to those generated by the active electrode. The dielectric layer on the passive electrode causes that gaseous discharges such as breakdown streamers or arc start at lower voltages than they could in the case of normal corona discharge. The visual forms of the discharge were recorded and correlated with the current-voltage characteristics and optical emission spectra. Emission spectra of the discharge were measured in the light wavelength range of 200 to 600 nm to get information about excitation and ionisation processes. The light spectra were analysed by monochromator SPM-2 Karl-Zeiss-Jena with diffraction grating of 1302 grooves/mm and photomultiplier R375 (Hamamatsu) and signal preamplifier unit C7319 (Hamamatsu). The spectral analysis showed that the nitrogen molecular bands were dominant, but the emission of negative ions from the dielectric layer material were also detected. The most noticeable light emission in the range from 280 to 490 nm due to second

  11. Interpretation of the lime column penetration test

    International Nuclear Information System (INIS)

    Liyanapathirana, D S; Kelly, R B

    2010-01-01

    Dry soil mix (DSM) columns are used to reduce the settlement and to improve the stability of embankments constructed on soft clays. During construction the shear strength of the columns needs to be confirmed for compliance with technical assumptions. A specialized blade shaped penetrometer known as the lime column probe, has been developed for testing DSM columns. This test can be carried out as a pull out resistance test (PORT) or a push in resistance test (PIRT). The test is considered to be more representative of average column shear strength than methods that test only a limited area of the column. Both PORT and PIRT tests require empirical correlations of measured resistance to an absolute measure of shear strength, in a similar manner to the cone penetration test. In this paper, finite element method is used to assess the probe factor, N, for the PORT test. Due to the large soil deformations around the probe, an Arbitrary Lagrangian Eulerian (ALE) based finite element formulation has been used. Variation of N with rigidity index and the friction at the probe-soil interface are investigated to establish a range for the probe factor.

  12. Stability of titania nanoparticles in soil suspensions and transport in saturated homogeneous soil columns

    International Nuclear Information System (INIS)

    Fang Jing; Shan Xiaoquan; Wen Bei; Lin Jinming; Owens, Gary

    2009-01-01

    The stability of TiO 2 nanoparticles in soil suspensions and their transport behavior through saturated homogeneous soil columns were studied. The results showed that TiO 2 could remain suspended in soil suspensions even after settling for 10 days. The suspended TiO 2 contents in soil suspensions after 24 h were positively correlated with the dissolved organic carbon and clay content of the soils, but were negatively correlated with ionic strength, pH and zeta potential. In soils containing soil particles of relatively large diameters and lower solution ionic strengths, a significant portion of the TiO 2 (18.8-83.0%) readily passed through the soils columns, while TiO 2 was significantly retained by soils with higher clay contents and salinity. TiO 2 aggregate sizes in the column outflow significantly increased after passing through the soil columns. The estimated transport distances of TiO 2 in some soils ranged from 41.3 to 370 cm, indicating potential environmental risk of TiO 2 nanoparticles to deep soil layers. - TiO 2 nanoparticles could efficiently suspend in soil suspensions and potentially transport to deeper soil layers

  13. Stability of titania nanoparticles in soil suspensions and transport in saturated homogeneous soil columns

    Energy Technology Data Exchange (ETDEWEB)

    Fang Jing [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Shan Xiaoquan [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)], E-mail: xiaoquan@rcees.ac.cn; Wen Bei [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)], E-mail: bwen@rcees.ac.cn; Lin Jinming [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Owens, Gary [Centre for Environmental Risk Assessment and Remediation, University of South Australia, Mawson Lakes, SA 5095 (Australia)

    2009-04-15

    The stability of TiO{sub 2} nanoparticles in soil suspensions and their transport behavior through saturated homogeneous soil columns were studied. The results showed that TiO{sub 2} could remain suspended in soil suspensions even after settling for 10 days. The suspended TiO{sub 2} contents in soil suspensions after 24 h were positively correlated with the dissolved organic carbon and clay content of the soils, but were negatively correlated with ionic strength, pH and zeta potential. In soils containing soil particles of relatively large diameters and lower solution ionic strengths, a significant portion of the TiO{sub 2} (18.8-83.0%) readily passed through the soils columns, while TiO{sub 2} was significantly retained by soils with higher clay contents and salinity. TiO{sub 2} aggregate sizes in the column outflow significantly increased after passing through the soil columns. The estimated transport distances of TiO{sub 2} in some soils ranged from 41.3 to 370 cm, indicating potential environmental risk of TiO{sub 2} nanoparticles to deep soil layers. - TiO{sub 2} nanoparticles could efficiently suspend in soil suspensions and potentially transport to deeper soil layers.

  14. Yield of Ozone, Nitrite Nitrogen and Hydrogen Peroxide Versus Discharge Parameter Using APPJ Under Water

    International Nuclear Information System (INIS)

    Chen Bingyan; Wen Wen; Zhu Changping; Wang Yuan; Gao Ying; Fei Juntao; He Xiang; Yin Cheng; Jiang Yongfeng; Chen Longwei

    2016-01-01

    Discharge plasma in and in contact with water can be accompanied with ultraviolet radiation and electron impact, thus can generate hydroxyl radicals, ozone, nitrite nitrogen and hydrogen peroxide. In this paper, a non-equilibrium plasma processing system was established by means of an atmospheric pressure plasma jet immersed in water. The hydroxyl intensities and discharge energy waveforms were tested. The results show that the positive and negative discharge energy peaks were asymmetric, where the positive discharge energy peak was greater than the negative one. Meanwhile, the yield of ozone and nitrite nitrogen was enhanced with the increase of both the treatment time and the discharge energy. Moreover, the pH value of treated water was reduced rapidly and maintained at a lower level. The residual concentration of hydrogen peroxide in APPJ treated water was kept at a low level. Additionally, both the efficiency energy ratio of the yield of ozone and nitrite nitrogen and that of the removal of p-nitrophenol increased as a function of discharge energy and discharge voltage. The experimental results were fully analyzed and the chemical reaction equations and the physical processes of discharges in water were given. (paper)

  15. Behaviour of FRP confined concrete in square columns

    OpenAIRE

    Diego Villalón, Ana de; Arteaga Iriarte, Ángel; Fernandez Gomez, Jaime Antonio; Perera Velamazán, Ricardo; Cisneros, Daniel

    2015-01-01

    A significant amount of research has been conducted on FRP-confined circular columns, but much less is known about rectangular/square columns in which the effectiveness of confinement is much reduced. This paper presents the results of experimental investigations on low strength square concrete columns confined with FRP. Axial compression tests were performed on ten intermediate size columns. The tests results indicate that FRP composites can significantly improve the bearing capacity and duc...

  16. Numerical Simulations of Settlement of Jet Grouting Columns

    Directory of Open Access Journals (Sweden)

    Juzwa Anna

    2016-03-01

    Full Text Available The paper presents the comparison of results of numerical analyses of interaction between group of jet grouting columns and subsoil. The analyses were conducted for single column and groups of three, seven and nine columns. The simulations are based on experimental research in real scale which were carried out by authors. The final goal for the research is an estimation of an influence of interaction between columns working in a group.

  17. Nipple Discharge

    Science.gov (United States)

    ... any unexpected nipple discharge evaluated by a doctor. Nipple discharge in men under any circumstances could be a problem and needs further evaluation. One or both breasts may produce a nipple discharge, either spontaneously or when you squeeze your ...

  18. Strengthening of Steel Columns under Load: Torsional-Flexural Buckling

    Directory of Open Access Journals (Sweden)

    Martin Vild

    2016-01-01

    Full Text Available The paper presents experimental and numerical research into the strengthening of steel columns under load using welded plates. So far, the experimental research in this field has been limited mostly to flexural buckling of columns and the preload had low effect on the column load resistance. This paper focuses on the local buckling and torsional-flexural buckling of columns. Three sets of three columns each were tested. Two sets corresponding to the base section (D and strengthened section (E were tested without preloading and were used for comparison. Columns from set (F were first preloaded to the load corresponding to the half of the load resistance of the base section (D. Then the columns were strengthened and after they cooled, they were loaded to failure. The columns strengthened under load (F had similar average resistance as the columns welded without preloading (E, meaning the preload affects even members susceptible to local buckling and torsional-flexural buckling only slightly. This is the same behaviour as of the tested columns from previous research into flexural buckling. The study includes results gained from finite element models of the problem created in ANSYS software. The results obtained from the experiments and numerical simulations were compared.

  19. Study on two phase flow characteristics in annular pulsed extraction column with different ratio of annular width to column diameter

    International Nuclear Information System (INIS)

    Qin Wei; Dai Youyuan; Wang Jiading

    1994-01-01

    Annular pulsed extraction column can successfully provide large throughput and can be made critically safe for fuel reprocessing. This investigation is to study the two phase flow characteristics in annular pulsed extraction column with four different annular width. 30% TBP (in kerosene)-water is used (water as continuous phase). Results show that modified Pratt correlation is valid under the experimental operation conditions for the annular pulsed extraction column. The characteristic velocity U K decreased with the increase of energy input and increased with the increase of the ratio of annular width to column diameter. Flooding velocity correlation is suggested. The deviation of the calculated values from the experimental data is within +20% for four annular width in a pulsed extraction column

  20. Self-discharge of AC/AC electrochemical capacitors in salt aqueous electrolyte

    International Nuclear Information System (INIS)

    García-Cruz, L.; Ratajczak, P.; Iniesta, J.; Montiel, V.; Béguin, F.

    2016-01-01

    The self-discharge (SD) of electrochemical capacitors based on activated carbon electrodes (AC/AC capacitors) in aqueous lithium sulfate was examined after applying a three-hour cell potential hold at U i values from 1.0 to 1.6 V. The leakage current measured during the potentiostatic period as well as the amplitude of self-discharge increased with U i ; the cell potential drop was approximately doubled by 10 °C increase of temperature. The potential decay of both negative and positive electrodes was explored separately, by introducing a reference electrode and it was found that the negative electrode contributes essentially to the capacitor self-discharge. A diffusion-controlled mechanism was found at U i ≤ 1.4 V and U i ≤ 1.2 V for the positive and negative electrodes, respectively. At higher U i of 1.6 V, both electrodes display an activation-controlled mechanism due to water oxidation and subsequent carbon oxidation at the positive electrode and water or oxygen reduction at the negative electrode.

  1. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  2. Studies of transport phenomena in tokamaks with nonstationary intervention into the discharge

    International Nuclear Information System (INIS)

    Kalmykov, S.G.

    1993-01-01

    Together with detailed plasma parameter measurements, an experimental basis is provided to deduce radial profiles of local transport coefficients, to obtain their temporal evolution in the transient phase of the discharge. The equations of heat and particle balance were used as proper instrument to perform the coefficients calculation. The majority of the experiments deals with heat transport processes in the electron component of plasma. A problem in getting ohmic heat deposit radial distribution arise with use of the electron population heat balance equation. For its solution, numerical simulation of the plasma column loop voltage based on poloidal magnetic field classical diffusion supposition was used. (L.C.J.A.)

  3. Collapse of tall granular columns in fluid

    Science.gov (United States)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  4. Extreme-UV electrical discharge source

    Science.gov (United States)

    Fornaciari, Neal R.; Nygren, Richard E.; Ulrickson, Michael A.

    2002-01-01

    An extreme ultraviolet and soft x-ray radiation electric capillary discharge source that includes a boron nitride housing defining a capillary bore that is positioned between two electrodes one of which is connected to a source of electric potential can generate a high EUV and soft x-ray radiation flux from the capillary bore outlet with minimal debris. The electrode that is positioned adjacent the capillary bore outlet is typically grounded. Pyrolytic boron nitride, highly oriented pyrolytic boron nitride, and cubic boron nitride are particularly suited. The boron nitride capillary bore can be configured as an insert that is encased in an exterior housing that is constructed of a thermally conductive material. Positioning the ground electrode sufficiently close to the capillary bore outlet also reduces bore erosion.

  5. CUB DI (Deionization) column control system

    International Nuclear Information System (INIS)

    Seino, K.C.

    1999-01-01

    For the old MR (Main Ring), deionization was done with two columns in CUB, using an ion exchange process. Typically 65 GPM of LCW flew through a column, and the resistivity was raised from 3 Mohm-cm to over 12 Mohm-cm. After a few weeks, columns lost their effectiveness and had to be regenerated in a process involving backwashing and adding hydrochloric acid and sodium hydroxide. For normal MR operations, LCW returned from the ring and passed through the two columns in parallel for deionization, although the system could have been operated satisfactorily with only one in use. A 3000 gallon reservoir (the Spheres) provided a reserve of LCW for allowing water leaks and expansions in the MR. During the MI (Main Injector) construction period, the third DI column was added to satisfy requirements for the MI. When the third column was added, the old regeneration controller was replaced with a new controller based on an Allen-Bradley PLC (i.e., SLC-5/04). The PLC is widely used and well documented, and therefore it may allow us to modify the regeneration programs in the future. In addition to the above regeneration controller, the old control panels (which were used to manipulate pumps and valves to supply LCW in Normal mode and to do Int. Recir. (Internal Recirculation) and Makeup) were replaced with a new control system based on Sixtrak Gateway and I/O modules. For simplicity, the new regeneration controller is called as the US Filter system, and the new control system is called as the Fermilab system in this writing

  6. Electrochemical cell assembled in discharged state

    Science.gov (United States)

    Yao, Neng-Ping; Walsh, William J.

    1976-01-01

    A secondary, electrochemical cell is assembled in a completely discharged state within a sealed containment. As assembled, the cell includes a positive electrode separated from a negative electrode by a molten salt electrolyte. The positive electrode is contained within a porous structure, permitting passage of molten electrolyte, and includes one or more layers of a metallic mesh, e.g. iron, impregnated with an intimate mixture of lithium sulfide and the electrolyte. The negative electrode is a porous plaque of aluminum metal. Prior to using the cell, an electrical charge forms lithium-aluminum alloy within the negative electrode and metal sulfide within the positive electrode.

  7. Desalination Brine Discharge Impacts on Coastal Biology and Water Chemistry - A Case Study from Carlsbad Southern California

    Science.gov (United States)

    Petersen, K. L.; Heck, N.; Potts, D. C.; Paytan, A.

    2017-12-01

    Fresh water demand is increasing world-wide due to on-going droughts, climate change and increasing human population and associated demand for food and water. Desalination of seawater is a reliable source of potable water; however the effects of byproduct brine discharge from desalination plants on coastal areas have not been thoroughly assessed. Here we report results from in-situmeasurements of the effects of brine discharge on water chemistry and coastal biology from a desalination plant in Carlsbad, Southern California. We compared select parameters in the coastal zone around the discharge site before and after operation began and conducted additional controlled laboratory incubations with key coastal species and brine effluent. Our in-situ data shows differences in salinity and temperature between the discharge area and a control site both before and after the desalination plant started operation. The discharge water is warmer by 3-5 Co than the ambient seawater and a temperature gradient is seen around the discharge channel. This is likely a result of mixing of the desalination brine with power plant cooling water for dilution prior to discharge and the higher temperatures are not directly attributed to the desalination. Our post-discharge results show a decipherable salinity plume at the bottom of the water column ( 6 m depth) reaching up to 600 m offshore from the discharge site. This indicates inefficient mixing of the brine in the coastal discharge zone. No significant differences are found in nutrient levels, organic carbon or chlorophyll a concentrations around the discharge. The benthic biology assemblage post-discharge is significantly different from the pre-discharge organisms' assemblage. However, the role of seasonal changes in temperature may also have impacted the data as the sampling was conducted during different seasons. Controlled incubation experiments of brittle stars (Ophiothrix spiculata) shows no significant difference in growth or

  8. NOx retention in scrubbing column

    International Nuclear Information System (INIS)

    Nakazone, A.K.; Costa, R.E.; Lobao, A.S.T.; Matsuda, H.T.; Araujo, B.F.

    1988-07-01

    During the UO 2 dissolution in nitric acid, some different species of NO x are released. The off gas can either be refluxed to the dissolver or be released and retained on special columns. The final composition of the solution is the main parameter to take in account. A process for nitrous gases retention using scubber columns containing H 2 O or diluted HNO 3 is presented. Chemiluminescence measurement was employed to NO x evalution before and after scrubbing. Gas flow, temperature, residence time are the main parameters considered in this paper. For the dissolution of 100g UO 2 in 8M nitric acid, a 6NL/h O 2 flow was the best condition for the NO/NO 2 oxidation with maximum adsorption in the scrubber columns. (author) [pt

  9. Influence of the polarity of the applied voltage on the reignition of a discharge below a dielectric layer in air at atmospheric pressure

    International Nuclear Information System (INIS)

    Pechereau, François; Bourdon, Anne

    2014-01-01

    The dynamics of an atmospheric pressure air discharge in a point-to-plane geometry with a dielectric layer obstacle on the discharge path is investigated numerically for different applied voltages. Whatever the polarity of the voltage applied, first, a streamer discharge of the same polarity ignites at the point and propagates towards the dielectric layer. After the impact on the dielectric surface, the streamer discharge spreads along the upper dielectric surface and charges it positively or negatively depending on its polarity. On the bottom surface of the dielectric layer, charges with an opposite polarity are deposited. Surface charges on both faces of the dielectric layer are shown to have a significant influence on the discharge reignition for a negative applied voltage, but not for a positive one. Furthermore, it is shown that the dynamics of the discharge reignition below the dielectric layer depends on the polarity of the applied voltage at the point electrode. For a positive applied voltage, the reignited discharge is a positive ionization wave propagating towards the grounded plane. For a negative applied voltage, a double headed discharge is observed with positive and negative fronts propagating in opposite directions. Finally, the minimal value of the ionization integral to have a discharge reignition below the dielectric obstacle is found to be less for a negative applied voltage than for a positive one. (paper)

  10. Modalization in the Political Column of Tempo Magazine

    OpenAIRE

    Rahmah, Maria Betti Sinaga and

    2017-01-01

    The study focuses on analyzing the use of modalization in the Political Column of Tempo Magazine. The objectives were to find out the type of modalization and to describe the use of modalization in the Political Column of Tempo magazine. The data were taken from Political Column of Tempo magazine published in June and July 2017. The source of data was Political Column in Tempo magazine. The data analysis applied descriptive qualitative research. There were 135 clauses which contained Modaliza...

  11. Examining the Utility of Coral Ba/Ca as a Paleo-Proxy for Interannual River Discharge Variability Along the Pacific Coast of Panamá

    Science.gov (United States)

    Brenner, L. D.; Linsley, B. K.; Dunbar, R. B.

    2016-02-01

    Climate along the Pacific coast of Panamá is largely dictated by seasonal N/S shifts in the Intertropical Convergence zone (ITCZ) and the consequent oscillations in precipitation. During the Panamanian wet season (May-Nov.) river discharge (Q) reaches its maximum and serves as a potential source of trace elements, such as Ba, to reefs. Near shore corals can record the waterborne trace metal history in their aragonite skeletons, which can then be exploited as a paleo-proxy for river discharge. We present two high-resolution Ba/Ca records from nearby Porites corals in the Gulf of Chiriquí, Panamá in an effort to better understand the long-term discharge and precipitation history of the region. Both corals record similar annual average Ba/Ca values throughout the time series' (R=0.55) suggesting that they are faithfully recording water column Ba levels at a large scale. A monthly composite average of both coral Ba/Ca records is positively correlated to an average of all available river discharge data (n= 5) (R=0.42). While instrumental data are relatively sparse and discontinuous, there is a significant relationship between the two variables producing a Ba/Ca-discharge relationship where Q (m3/s)= Ba/Ca(μmol/mol)×49.97(μmol/mol)(m3/s)-1-190.85. The Ba/Ca peaks correspond to the annual minima in our paired near-monthly resolved coral δ18O measurements, further supporting that maximum Q in the Gulf is concurrent with the annual salinity minima and precipitation maximum. Coral Ba/Ca in the Gulf of Chiriquí indicates that annual average river Q into the Gulf has varied from 50 to 133 m3/s over from 1966 to 1983. As inferred from our Ba/Ca data, interannual variability of river Q accounts for 25% of total variance (after removing the seasonal cycle) and a long-term secular trend of increasing river Q accounts for 30%. Our Porites coral Ba/Ca records from the Pacific side of Panamá provide an opportunity to supplement the limited instrumental river discharge data

  12. Column, particularly extraction column, for fission and/or breeder materials

    International Nuclear Information System (INIS)

    Vietzke, H.; Pirk, H.

    1980-01-01

    An absorber rod with a B 4 C insert is situated in the long extraction column for a uranyl nitrate solution or a plutonium nitrate solution. The geometrical dimensions are designed for a high throughput with little corrosion. (DG) [de

  13. Posterior column reconstruction improves fusion rates at the level of osteotomy in three-column posterior-based osteotomies.

    Science.gov (United States)

    Lewis, Stephen J; Mohanty, Chandan; Gazendam, Aaron M; Kato, So; Keshen, Sam G; Lewis, Noah D; Magana, Sofia P; Perlmutter, David; Cape, Jennifer

    2018-03-01

    To determine the incidence of pseudarthrosis at the osteotomy site after three-column spinal osteotomies (3-COs) with posterior column reconstruction. 82 consecutive adult 3-COs (66 patients) with a minimum of 2-year follow-up were retrospectively reviewed. All cases underwent posterior 3-COs with two-rod constructs. The inferior facets of the proximal level were reduced to the superior facets of the distal level. If that was not possible, a structural piece of bone graft either from the local resection or a local rib was slotted in the posterior column defect to re-establish continual structural posterior bone across the lateral margins of the resection. No interbody cages were used at the level of the osteotomy. There were 34 thoracic osteotomies, 47 lumbar osteotomies and one sacral osteotomy with a mean follow-up of 52 (24-126) months. All cases underwent posterior column reconstructions described above and the addition of interbody support or additional posterior rods was not performed for fusion at the osteotomy level. Among them, 29 patients underwent one or more revision surgeries. There were three definite cases of pseudarthrosis at the osteotomy site (4%). Six revisions were also performed for pseudarthrosis at other levels. Restoration of the structural integrity of the posterior column in three-column posterior-based osteotomies was associated with > 95% fusion rate at the level of the osteotomy. Pseudarthrosis at other levels was the second most common reason for revision following adjacent segment disease in the long-term follow-up.

  14. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    Science.gov (United States)

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte). Copyright © 2016 Elsevier B.V. All rights reserved.

  15. The Past, Present, and Future of Discharge Planning in Taiwan

    Directory of Open Access Journals (Sweden)

    Shu-Chuan Lin

    2013-06-01

    Full Text Available Discharge planning is an interdisciplinary approach to provide continuity of care; it is a process that includes identification, assessment, goal setting, planning, implementation, coordination, and evaluation. Discharge planning has been viewed as a major way to enhance a smooth transition for patients from the hospital to home or other chronic care units and as a solution to solve problems associated with postdischarge care. The promotion of discharge planning began in the United States in the 1960s. Nursing scholars from Taiwan learned about the concept of discharge planning from the United States in the early 1980s and subsequently introduced it to Taiwanese medical institutions in 1985. A policy to promote discharge planning in Taiwan was announced by the Executive Yuan, Department of Health in 1993. Following the healthcare reforms in 1995, discharge planning has since been strongly promoted. Studies concerning discharge planning in Taiwan showed some promising results, including increased satisfaction of patients and their families, improved preparation of caregivers, and improved quality of life for patients. However, patients receiving interdisciplinary discharge planning services were still in the minority. There was no standard evaluation procedure for interdisciplinary discharge planning, and a high percentage of patients thought that hospitals handled the postdischarge long-term care services referral procedure inadequately. Despite the positive attitudes toward discharge planning, many physicians still demonstrate an unsatisfactory level of knowledge and behaviors with regard to discharge planning. To enhance the implementation of discharge planning, a standard evaluation procedure for interdisciplinary discharge planning and improved physician awareness concerning the importance of discharge planning are needed. In Taiwan, the improvement of discharge planning in the foreseeable future is promising with the accreditation of the

  16. Bundling the value of discharge telephone calls and leader rounding.

    Science.gov (United States)

    Setia, Nina; Meade, Christine

    2009-03-01

    Discharge telephone calls made by hospital staff provide invaluable opportunities to prevent adverse events, improve quality of care, and increase patient satisfaction. Similarly, the effect of rounding on patients can improve clinical quality and improve both patient and staff satisfaction. The author discusses how the combination of implementing both nurse leader rounding and discharge telephone calls simultaneously produced powerful positive outcomes in satisfaction and patient quality of care.

  17. Fate of parabens and 4-hydroxybenzoic acid in aquifer materials columns during step experiments with fresh and sea waters

    Science.gov (United States)

    López-Ortiz, C. M.; Boluda-Botella, N.; Prats-Rico, D.; Sentana-Gadea, I.

    2018-02-01

    Coastal areas submitted to seawater intrusion and with discharges from urban and industrial wastewaters, municipal landfill leachates, rivers, recreational waters and other sources are sensitive to be polluted with parabens. Understanding the fate of these compounds in environmental studies, it requires previously the knowledge of the reactive processes in controlled conditions. In this research, laboratory columns experiments were carried out with a group of parabens (methyl-, ethyl-, propyl- and butylparaben) and their main degradation compound (4-hydroxybenzoic acid) to study mainly the dynamic sorption processes in different aquifer materials (100% sand and heterogeneous: 81% sand, 9% silt and 10% clay) and with fresh and sea waters, the end members of seawater intrusions. To the column hydrodynamic characterization, tracer assays with increase and decrease of salinity were performed, to obtain the mean residence time of each column and other transport parameters which allow us to compare parabens' sorption in different conditions. The results of the adsorption and desorption of parabens in the sand column demonstrated be fast and simultaneous, with a short delay and without influence of the water salinity. Very different results were found in the column experiments with heterogeneous material, where the presence of clay and organic matter increase the time of adsorption/desorption as the length of the alkyl chain paraben increased, according with their hydrophobicity. It should be noted that despite the quick desorption of the major quantities of parabens, the elution of their trace concentrations was very slow (for the seawater, the buthylparaben required a dimensionless time of 800). Planning the restoration of a coastal aquifer with freshwater, and in the conditions of the studied sand column experiment, it will need a dimensionless time of 160. However, it is necessary to take into account that the studied parabens and 4-hydroxybenzoic acid are

  18. Vessel Sewage Discharges: No-Discharge Zones (NDZs)

    Science.gov (United States)

    States may petition the EPA to establish areas, called no discharge zones (NDZs), where vessel sewage discharges are prohibited. This page describes how NDZs are designated, the types of designations, who enforces them, and how to comply.

  19. Systematic investigation of the barrier discharge operation in helium, nitrogen, and mixtures: discharge development, formation and decay of surface charges

    Science.gov (United States)

    Tschiersch, R.; Bogaczyk, M.; Wagner, H.-E.

    2014-09-01

    As a logical extension to previous investigations of the barrier discharge (BD) in helium and nitrogen, the present work reports on the operation in any mixtures of both pure gases. Using a well-established plane-parallel discharge cell configuration allows to study the influence of the He/N2 mixing ratio on the formation of different discharge modes. Their characterization was made by measuring the discharge emission development together with the formation and decay of surface charges on a bismuth silicon oxide (Bi12SiO20, BSO) crystal. This was realized by the simultaneous application of the spatio-temporally resolved optical emission spectroscopy, and the electro-optic Pockels effect in combination with a CCD high speed camera. The existence diagram for diffuse and filamentary BDs was determined by varying the amplitude and shape of the applied voltage. Over the entire range of the He/N2 ratio, the diffuse mode can be operated at moderate voltage amplitudes whereas filamentation occurs at significant overvoltage and is favoured by a high voltage slew rate. Irrespective of the discharge mode, the overall charge transfer during a discharge breakdown is found to be in excellent agreement with the amount of accumulated surface charges. An exponential decay of the surface charge deposited on the BSO crystal is induced by LED illumination beyond a typical discharge cycle. During the decay process, a broadening of the radial profiles of positive as well as negative surface charge spots originating from previous microdischarges is observed. The investigations contribute to a better understanding of the charge accumulation at a dielectric.

  20. A simulation-optimization model for Stone column-supported embankment stability considering rainfall effect

    International Nuclear Information System (INIS)

    Deb, Kousik; Dhar, Anirban; Purohit, Sandip

    2016-01-01

    Landslide due to rainfall has been and continues to be one of the most important concerns of geotechnical engineering. The paper presents the variation of factor of safety of stone column-supported embankment constructed over soft soil due to change in water level for an incessant period of rainfall. A combined simulation-optimization based methodology has been proposed to predict the critical surface of failure of the embankment and to optimize the corresponding factor of safety under rainfall conditions using an evolutionary genetic algorithm NSGA-II (Non-Dominated Sorted Genetic Algorithm-II). It has been observed that the position of water table can be reliably estimated with varying periods of infiltration using developed numerical method. The parametric study is presented to study the optimum factor of safety of the embankment and its corresponding critical failure surface under the steady-state infiltration condition. Results show that in case of floating stone columns, period of infiltration has no effect on factor of safety. Even critical failure surfaces for a particular floating column length remain same irrespective of rainfall duration

  1. A simulation-optimization model for Stone column-supported embankment stability considering rainfall effect

    Energy Technology Data Exchange (ETDEWEB)

    Deb, Kousik, E-mail: kousik@civil.iitkgp.ernet.in [Associate Professor, Department of Civil Engineering, IIT Kharagpur, Kharagpur-721302 (India); Dhar, Anirban, E-mail: anirban@civil.iitkgp.ernet.in [Assistant Professor, Department of Civil Engineering, IIT Kharagpur, Kharagpur-721302 (India); Purohit, Sandip, E-mail: sandip.purohit91@gmail.com [Former B.Tech Student, Department of Civil Engineering, NIT Rourkela, Rourkela (India)

    2016-02-01

    Landslide due to rainfall has been and continues to be one of the most important concerns of geotechnical engineering. The paper presents the variation of factor of safety of stone column-supported embankment constructed over soft soil due to change in water level for an incessant period of rainfall. A combined simulation-optimization based methodology has been proposed to predict the critical surface of failure of the embankment and to optimize the corresponding factor of safety under rainfall conditions using an evolutionary genetic algorithm NSGA-II (Non-Dominated Sorted Genetic Algorithm-II). It has been observed that the position of water table can be reliably estimated with varying periods of infiltration using developed numerical method. The parametric study is presented to study the optimum factor of safety of the embankment and its corresponding critical failure surface under the steady-state infiltration condition. Results show that in case of floating stone columns, period of infiltration has no effect on factor of safety. Even critical failure surfaces for a particular floating column length remain same irrespective of rainfall duration.

  2. Spatial and temporal distributions of toxicity in receiving waters around an oil effluent discharge site

    International Nuclear Information System (INIS)

    Krause, P.R.

    1994-01-01

    Distributions of pollutants from a point source discharge within the water column may vary in both time and space. In this study, they examined the spatial and temporal patterns of toxicity from an oil production effluent (produced water) discharge plume using sea urchin fertilization and development bioassays. Specifically, they tested the sensitivity and response patterns of sea urchin gametes and early life stages exposed to receiving waters sampled along a 1 km transact near an active produced water outfall. Fertilization success and development of larvae to the pluteus stage varied significantly with proximity to the outfall, with reduced fertilization and larval development found closer to the outfall. Although estimated toxicity in receiving water samples, based on fertilization success, was variable in time -- perhaps responding to variation in the quantity or make-up of produced water discharges -- the general spatial pattern of toxicity along the sampling transact remained relatively constant. Strong evidence that field toxicity was directly attributable to produced water effluents was provided by sampling the receiving waters while the produced water discharge was not operating. At such a time, no toxicity was found at any of the field sites. Receiving water toxicity data, along with toxicity data from the effluent itself, were used to prepare a ''map'' of effective effluent concentrations along the sampling transect

  3. Water hammer with column separation : a historical review

    NARCIS (Netherlands)

    Bergant, A.; Simpson, A.R.; Tijsseling, A.S.

    2006-01-01

    Column separation refers to the breaking of liquid columns in fully filled pipelines. This may occur in a water-hammer event when the pressure in a pipeline drops to the vapor pressure at specific locations such as closed ends, high points or knees (changes in pipe slope). The liquid columns are

  4. Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage

    Science.gov (United States)

    Yuanxiang, ZHOU; Zhongliu, ZHOU; Ling, ZHANG; Yunxiao, ZHANG; Yajun, MO; Jiantao, SUN

    2018-05-01

    For the partial discharge test of electrical equipment with large capacitance, the use of low-frequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply. However, the validity of PD test under low frequency voltage needs to be evaluated. In order to investigate the influence of voltage frequency on corona discharge in the air, the discharge test of the tip-plate electrode under the frequency from 50 to 0.1 Hz is carried out based on the impulse current method. The results show that some of the main features of corona under low frequency do not change. The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle. The magnitude of discharge and interval in positive cycle are random, while that in negative cycle are regular. With the decrease of frequency, the inception voltage increases. The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated, with discussion and interpretation from the aspects of space charge transportation, effective discharge time and transition of discharge modes. There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency. The experimental results can be the reference for mode identification of partial discharge under low frequency tests. The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency (usually 50 Hz). Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.

  5. HPLC-CUPRAC post-column derivatization method for the determination of antioxidants: a performance comparison between porous silica and core-shell column packing.

    Science.gov (United States)

    Haque, Syed A; Cañete, Socrates Jose P

    2018-01-01

    An HPLC method employing a post-column derivatization strategy using the cupric reducing antioxidant capacity reagent (CUPRAC reagent) for the determining antioxidants in plant-based materials leverages the separation capability of regular HPLC approaches while allowing for detection specificity for antioxidants. Three different column types, namely core-shell and porous silica including two chemically different core-shell materials (namely phenyl-hexyl and C18), were evaluated to assess potential improvements that could be attained by changing from a porous silica matrix to a core-shell matrix. Tea extracts were used as sample matrices for the evaluation specifically looking at catechin and epigallocatechin gallate (EGCG). Both the C18 and phenyl-hexyl core-shell columns showed better performance compared to the C18 porous silica one in terms of separation, peak shape, and retention time. Among the two core-shell materials, the phenyl-hexyl column showed better resolving power compared to the C18 column. The CUPRAC post-column derivatization method can be improved using core-shell columns and suitable for quantifying antioxidants, exemplified by catechin and EGCG, in tea samples.

  6. Study on Progressive Collapse Behavior of SRC Column-Steel Beam Hybrid Frame Based on Pushdown Analysis

    Directory of Open Access Journals (Sweden)

    Liusheng Chu

    2017-01-01

    Full Text Available To investigate the progressive collapse behavior of Steel Reinforced Concrete (SRC column-steel beam hybrid frame after the failure of key structural elements, a PQ-Fiber model for an 8-storey structure is established in ABAQUS program. Nonlinear dynamic and static pushdown analysis are carried out after the failure and removal of the bottom-middle and bottom-corner columns. Numerical results of both methods agree well with each other. Results show that SRC column-steel frame has good resistance to progressive collapse under dynamic instantaneous load. After sudden removal of a bottom middle column, the development of structural collapse exhibits two mechanisms, the beam mechanism and the catenary mechanism. When the structure is within small deformation range, the collapse resistance of the residual frame is provided by the beam bending moment capacity, which is beam mechanism. For large deformation situation, the collapse resistance is mainly provided by the beam tensile strength, which is catenary mechanism. However, with the removal of a bottom corner column, the residual structure only undergoes the beam mechanism even for large deformations. For future practical applications, the influence of the steel ratio, steel section size, and the vertical position of the removed key components are investigated through a detailed parametric study.

  7. Risks predicting prolonged hospital discharge boarding in a regional acute care hospital.

    Science.gov (United States)

    Shaikh, Sajid A; Robinson, Richard D; Cheeti, Radhika; Rath, Shyamanand; Cowden, Chad D; Rosinia, Frank; Zenarosa, Nestor R; Wang, Hao

    2018-01-30

    Prolonged hospital discharge boarding can impact patient flow resulting in upstream Emergency Department crowding. We aim to determine the risks predicting prolonged hospital discharge boarding and their direct and indirect effects on patient flow. Retrospective review of a single hospital discharge database was conducted. Variables including type of disposition, disposition boarding time, case management consultation, discharge medications prescriptions, severity of illness, and patient homeless status were analyzed in a multivariate logistic regression model. Hospital charges, potential savings of hospital bed hours, and whether detailed discharge instructions provided adequate explanations to patients were also analyzed. A total of 11,527 admissions was entered into final analysis. The median discharge boarding time was approximately 2 h. Adjusted Odds Ratio (AOR) of patients transferring to other hospitals was 7.45 (95% CI 5.35-10.37), to court or law enforcement custody was 2.51 (95% CI 1.84-3.42), and to a skilled nursing facility was 2.48 (95% CI 2.10-2.93). AOR was 0.57 (95% CI 0.47-0.71) if the disposition order was placed during normal office hours (0800-1700). AOR of early case management consultation was 1.52 (95% CI 1.37-1.68) versus 1.73 (95% CI 1.03-2.89) for late consultation. Eighty-eight percent of patients experiencing discharge boarding times within 2 h of disposition expressed positive responses when questioned about the quality of explanations of discharge instructions and follow-up plans based on satisfaction surveys. Similar results (86% positive response) were noted among patients whose discharge boarding times were prolonged (> 2 h, p = 0.44). An average charge of $6/bed/h was noted in all hospital discharges. Maximizing early discharge boarding (≤ 2 h) would have resulted in 16,376 hospital bed hours saved thereby averting $98,256.00 in unnecessary dwell time charges in this study population alone. Type of disposition, case

  8. The effect of direction of illumination upon the visibility of a smoke column

    Science.gov (United States)

    Charles C. Buck; Wallace L. Fons

    1935-01-01

    Preliminary investigations in the detection of forest fires at the California Forest and Range Experiment Station were based on the assumption that the visibility of smoke columns in the field would vary as the visibility of the landscape with varying conditions of atmospheric suspensoid concentration and with the position of the sun. This led to the determination of...

  9. Remediation of groundwater contaminated with arsenic through enhanced natural attenuation: Batch and column studies.

    Science.gov (United States)

    Hafeznezami, Saeedreza; Zimmer-Faust, Amity G; Jun, Dukwoo; Rugh, Megyn B; Haro, Heather L; Park, Austin; Suh, Jae; Najm, Tina; Reynolds, Matthew D; Davis, James A; Parhizkar, Tarannom; Jay, Jennifer A

    2017-10-01

    Batch and column laboratory experiments were conducted on natural sediment and groundwater samples from a contaminated site in Maine, USA with the aim of lowering the dissolved arsenate [As(V)] concentrations through chemical enhancement of natural attenuation capacity. In batch factorial experiments, two levels of treatment for three parameters (pH, Ca, and Fe) were studied at different levels of phosphate to evaluate their impact on As(V) solubility. Results illustrated that lowering pH, adding Ca, and adding Fe significantly increased the sorption capacity of sediments. Overall, Fe amendment had the highest individual impact on As(V) levels. To provide further evidence for the positive impact of Ca on As(V) adsorption, isotherm experiments were conducted at three different levels of Ca concentrations. A consistent increase in adsorption capacity (26-37%) of sediments was observed with the addition of Ca. The observed favorable effect of Ca on As(V) adsorption is likely caused by an increase in the surface positive charges due to surface accumulation of Ca 2+ ions. Column experiments were conducted by flowing contaminated groundwater with elevated pH, As(V), and phosphate through both uncontaminated and contaminated sediments. Potential in-situ remediation scenarios were simulated by adding a chemical amendment feed to the columns injecting Fe(II) or Ca as well as simultaneous pH adjustment. Results showed a temporary and limited decrease in As(V) concentrations under the Ca treatment (39-41%) and higher levels of attenuation in Fe(II) treated columns (50-91%) but only after a certain number of pore volumes (18-20). This study illustrates the importance of considering geochemical parameters including pH, redox potential, presence of competing ions, and sediment chemical and physical characteristics when considering enhancing the natural attenuation capacity of sediments to mitigate As contamination in natural systems. Copyright © 2017 Elsevier Ltd. All rights

  10. Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column.

    Science.gov (United States)

    Hemdan, A; Abdel-Aziz, Omar

    2018-04-01

    Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic column as an alternative to traditional C-18 column was tested for fast separation of pharmaceuticals, where the results were very competitive. The performance comparison of both columns was tested for separation of anti-diabetic combination containing Metformin, Pioglitazone and Glimepiride using Gliclazide as an internal standard. Working at high flow rates with less significant backpressure was obtained with the monolithic column where the run time was reduced from 6 min in traditional column to only 1 min in monolithic column with accepted resolution. The structure of the monolith contains many pores which can adapt the high flow rate of the mobile phase. Moreover, peak symmetry and equilibration time were more efficient with monolithic column.

  11. 75 FR 57163 - Guidance Regarding Deferred Discharge of Indebtedness Income of Corporations and Deferred...

    Science.gov (United States)

    2010-09-20

    ... Consistent with Historical Practice --In General''. 2. On page 49400, in the third column, in the second full paragraph, in line six ``occurring prior to August 11, 2010 by taking a return position consistent with these provisions'' should read ``occurring prior to August 11, 2010, by taking a return position...

  12. Interaction of plasma with magnetic fields in coaxial discharge

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.

    1991-01-01

    Previous experiments have shown that, in normal mode of focus operation (67 KJ-20 KV) i.e. without external magnetic fields, the focus exhibits instability growths as revealed by the time integrated X-ray pinhole photographs. A magnetic field which is trapped ahead of the current sheath will reduce the high ejection rate of plasma which occurs during the (r,z) collapse stage. This reduction should lead to a more uniform plasma of larger dimension. If an externally excited axial magnetic field of (10 2 -10 3 G) is introduced at the end of the central electrode of coaxial discharge with 45 μf capacitor bank, U ch =13-17 KV, peak current ∼0.5 MA, the decay rate of the current sheath is slowed down and the minimum radius of the column remains large enough. Experiment investigation of the X-ray emission in axial direction from a (12 KJ/20 KV, 480 KA), Mather type focus, showed that the X-ray intensity changes drastically, by superimposing an axial magnetic field of 55 G on the focus. By introducing an external axial magnetic field of intensity 2.4 KG along the coaxial electrodes, this magnetic field has a radial component at distances approach to muzzle of coaxial discharge with charging voltage 10 KV and peak discharge current 100 KA. Presence of these magnetic fields, will cause an increase in intensity of soft X-ray emission. The main purpose of this work is to study the interactions of axial and transverse magnetic fields with plasma sheath during the axial interelectrode propagation, and its effects on the X-ray emission from plasma focus. (author) 4 refs., 7 figs

  13. Preparation and evaluation of 400μm I.D. polymer-based hydrophilic interaction chromatography monolithic columns with high column efficiency.

    Science.gov (United States)

    Liu, Chusheng; Li, Haibin; Wang, Qiqin; Crommen, Jacques; Zhou, Haibo; Jiang, Zhengjin

    2017-08-04

    The quest for higher column efficiency is one of the major research areas in polymer-based monolithic column fabrication. In this research, two novel polymer-based HILIC monolithic columns with 400μm I.D.×800μm O.D. were prepared based on the thermally initiated co-polymerization of N,N-dimethyl-N-(3-methacrylamidopropyl)-N-(3-sulfopropyl) ammonium betaine (SPP) and ethylene glycol dimethacrylate (EDMA) or N,N'-methylenebisacrylamide (MBA). In order to obtain a satisfactory performance in terms of column permeability, mechanical stability, efficiency and selectivity, the polymerization parameters were systematically optimized. Column efficiencies as high as 142, 000 plates/m and 120, 000 plates/m were observed for the analysis of neutral compounds at 0.6mm/s on the poly(SPP-co-MBA) and poly(SPP-co-EDMA) monoliths, respectively. Furthermore, the Van Deemter plots for thiourea on the two monoliths were compared with that on a commercial silica based ZIC-HILIC column (3.5μm, 200Å, 150mm×300μm I.D.) using ACN/H 2 O (90/10, v/v) as the mobile phase at room temperature. It was noticeable that the Van Deemter curves for both monoliths, particularly the poly(SPP-co-MBA) monolith, are significantly flatter than that obtained for the ZIC-HILIC column, which indicates that in spite of their larger internal diameters, they yield better overall efficiency, with less peak dispersion, across a much wider range of usable linear velocities. A clearly better separation performance was also observed for nucleobases, nucleosides, nucleotides and small peptides on the poly(SPP-co-MBA) monolith compared to the ZIC-HILIC column. It is particularly worth mentioning that these 400μm I.D. polymer-based HILIC monolithic columns exhibit enhanced mechanical strength owing to the thicker capillary wall of the fused-silica capillaries. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. HEAT TRANSFER ANALYSIS FOR FIXED CST AND RF COLUMNS

    International Nuclear Information System (INIS)

    Lee, S

    2007-01-01

    In support of a small column ion exchange (SCIX) process for the Savannah River Site waste processing program, transient and steady state two-dimensional heat transfer models have been constructed for columns loaded with cesium-saturated crystalline silicotitanate (CST) or spherical Resorcinol-Formaldehyde (RF) beads and 6 molar sodium tank waste supernate. Radiolytic decay of sorbed cesium results in heat generation within the columns. The models consider conductive heat transfer only with no convective cooling and no process flow within the columns (assumed column geometry: 27.375 in ID with a 6.625 in OD center-line cooling pipe). Heat transfer at the column walls was assumed to occur by natural convection cooling with 35 C air. A number of modeling calculations were performed using this computational heat transfer approach. Minimal additional calculations were also conducted to predict temperature increases expected for salt solution processed through columns of various heights at the slowest expected operational flow rate of 5 gpm. Results for the bounding model with no process flow and no active cooling indicate that the time required to reach the boiling point of ∼130 C for a CST-salt solution mixture containing 257 Ci/liter of Cs-137 heat source (maximum expected loading for SCIX applications) at 35 C initial temperature is about 6 days. Modeling results for a column actively cooled with external wall jackets and the internal coolant pipe (inlet coolant water temperature: 25 C) indicate that the CST column can be maintained non-boiling under these conditions indefinitely. The results also show that the maximum temperature of an RF-salt solution column containing 133 Ci/liter of Cs-137 (maximum expected loading) will never reach boiling under any conditions (maximum predicted temperature without cooling: 88 C). The results indicate that a 6-in cooling pipe at the center of the column provides the most effective cooling mechanism for reducing the maximum

  15. Novel field emission SEM column with beam deceleration technology

    International Nuclear Information System (INIS)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-01-01

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications

  16. Novel field emission SEM column with beam deceleration technology

    Energy Technology Data Exchange (ETDEWEB)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-11-15

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications.

  17. Dynamics of dielectric barrier discharges in coplanar arrangements

    International Nuclear Information System (INIS)

    Gibalov, Valentin I; Pietsch, Gerhard J

    2004-01-01

    The development of a discharge channel in coplanar dielectric barrier arrangements is investigated numerically. Its behaviour in oxygen, like the spatial and temporal distributions of the field strength, charged and neutral particles and energy density, is described in detail. It is found that the streamer development is mainly determined by photoemission. A cathode layer appears near the position where the cathode directed streamer touches the dielectric surface. Secondary electron emission by ion collisions becomes significant and the parameters of the cathode layer are near those of a normal glow discharge. The charge transfer and energy release happen in the conductive channel of the discharge, which appears on the dielectric surface as a result of the cathode streamer development. The field strength in the conductive channel is nearly constant and about 70-100 Td in oxygen and air

  18. High-speed micro-electro-discharge machining.

    Energy Technology Data Exchange (ETDEWEB)

    Chandrasekar, Srinivasan Dr. (.School of Industrial Engineering, West Lafayette, IN); Moylan, Shawn P. (School of Industrial Engineering, West Lafayette, IN); Benavides, Gilbert Lawrence

    2005-09-01

    When two electrodes are in close proximity in a dielectric liquid, application of a voltage pulse can produce a spark discharge between them, resulting in a small amount of material removal from both electrodes. Pulsed application of the voltage at discharge energies in the range of micro-Joules results in the continuous material removal process known as micro-electro-discharge machining (micro-EDM). Spark erosion by micro-EDM provides significant opportunities for producing small features and micro-components such as nozzle holes, slots, shafts and gears in virtually any conductive material. If the speed and precision of micro-EDM processes can be significantly enhanced, then they have the potential to be used for a wide variety of micro-machining applications including fabrication of microelectromechanical system (MEMS) components. Toward this end, a better understanding of the impacts the various machining parameters have on material removal has been established through a single discharge study of micro-EDM and a parametric study of small hole making by micro-EDM. The main avenues for improving the speed and efficiency of the micro-EDM process are in the areas of more controlled pulse generation in the power supply and more controlled positioning of the tool electrode during the machining process. Further investigation of the micro-EDM process in three dimensions leads to important design rules, specifically the smallest feature size attainable by the process.

  19. The design of a new concept chromatography column.

    Science.gov (United States)

    Camenzuli, Michelle; Ritchie, Harald J; Ladine, James R; Shalliker, R Andrew

    2011-12-21

    Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.

  20. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  1. Characteristics of an atmospheric pressure argon glow discharge in a coaxial electrode geometry

    International Nuclear Information System (INIS)

    Li Xuechen; Zhao Na; Fang Tongzhen; Liu Zhihui; Li Lichun; Dong Lifang

    2008-01-01

    An atmospheric glow discharge controlled by a dielectric barrier is realized in a coaxial electrode geometry in argon. The discharge characteristics are studied by the electrical method and optical emission spectroscopy. The experimental results indicate that there is only one discharge pulse per half cycle when the applied voltage is very low, and the rise time of the discharge pulses at the positive half cycle is much shorter than that at the negative one. With an increase in applied voltage, the width of the discharge pulse increases, while the inception voltage at which breakdown occurs decreases. The rise time at positive half cycle almost equals that at negative half cycle when the applied voltage is high enough. The research results pertaining to gas gap voltage indicate that the critical electric field for breakdown decreases with increasing applied voltage. The electron temperature is estimated from the Einstein relation, and the result indicates that the electron temperature and the electron density are functions of the applied voltage and the gas flow rate. The electron temperature is also studied by emission spectroscopy and a similar result is obtained

  2. State waste discharge permit application for cooling water and condensate discharges

    Energy Technology Data Exchange (ETDEWEB)

    Haggard, R.D.

    1996-08-12

    The following presents the Categorical State Waste Discharge Permit (SWDP) Application for the Cooling Water and Condensate Discharges on the Hanford Site. This application is intended to cover existing cooling water and condensate discharges as well as similar future discharges meeting the criteria set forth in this document.

  3. Dynamic effects of diabatization in distillation columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    The dynamic effects of diabatization in distillation columns are investigated in simulation emphasizing the heat-integrated distillation column (HIDiC). A generic, dynamic, first-principle model has been formulated, which is flexible enough to describe various diabatic distillation configurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found and control...

  4. Dynamic Effects of Diabatization in Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2012-01-01

    The dynamic eects of diabatization in distillation columns are investigated in simulation with primary focus on the heat-integrated distillation column (HIDiC). A generic, dynamic, rst-principle model has been formulated, which is exible to describe various diabatic distillation congurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found. Control...

  5. Fringing-field effects in acceleration columns

    International Nuclear Information System (INIS)

    Yavor, M.I.; Weick, H.; Wollnik, H.

    1999-01-01

    Fringing-field effects in acceleration columns are investigated, based on the fringing-field integral method. Transfer matrices at the effective boundaries of the acceleration column are obtained, as well as the general transfer matrix of the region separating two homogeneous electrostatic fields with different field strengths. The accuracy of the fringing-field integral method is investigated

  6. The influence of Congo River discharges in the surface and deep layers of the Gulf of Guinea

    OpenAIRE

    Vangriesheim, A.; Pierre, C.; Aminot, A.; Metzl, N.; Baurand, François; Caprais, J. C.

    2009-01-01

    The main feature of the Congo-Angola margin in the Gulf of Guinea is the Congo (ex-Zaire) deep-sea fan composed of a submarine canyon directly connected to the Congo River, a channel and a [sediment] lobe area. During the multi-disciplinary programme called BIOZAIRE conducted by Ifremer from 2000 to 2005, two CTD-O2 sections with discrete water column samples were performed (BIOZAIRE3 cruise: 2003-2004) to study the influence of the Congo River discharges, both in the surface layer and in the...

  7. Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography.

    Science.gov (United States)

    Mriziq, Khaled S; Guiochon, Georges

    2008-04-11

    The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC(x), taking place along one side of the bed and the second separation would be a time-based separation, LC(t), as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC(x) x LC(t) instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

  8. The transition mechanism from a symmetric single period discharge to a period-doubling discharge in atmospheric helium dielectric-barrier discharge

    International Nuclear Information System (INIS)

    Zhang, Dingzong; Wang, Yanhui; Wang, Dezhen

    2013-01-01

    Period-doubling and chaos phenomenon have been frequently observed in atmospheric-pressure dielectric-barrier discharges. However, how a normal single period discharge bifurcates into period-doubling state is still unclear. In this paper, by changing the driving frequency, we study numerically the transition mechanisms from a normal single period discharge to a period-doubling state using a one-dimensional self-consistent fluid model. The results show that before a discharge bifurcates into a period-doubling state, it first deviates from its normal operation and transforms into an asymmetric single period discharge mode. Then the weaker discharge in this asymmetric discharge will be enhanced gradually with increasing of the frequency until it makes the subsequent discharge weaken and results in the discharge entering a period-doubling state. In the whole transition process, the spatial distribution of the charged particle density and the electric field plays a definitive role. The conclusions are further confirmed by changing the gap width and the amplitude of the applied voltage

  9. The transition mechanism from a symmetric single period discharge to a period-doubling discharge in atmospheric helium dielectric-barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Dingzong; Wang, Yanhui; Wang, Dezhen [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China)

    2013-06-15

    Period-doubling and chaos phenomenon have been frequently observed in atmospheric-pressure dielectric-barrier discharges. However, how a normal single period discharge bifurcates into period-doubling state is still unclear. In this paper, by changing the driving frequency, we study numerically the transition mechanisms from a normal single period discharge to a period-doubling state using a one-dimensional self-consistent fluid model. The results show that before a discharge bifurcates into a period-doubling state, it first deviates from its normal operation and transforms into an asymmetric single period discharge mode. Then the weaker discharge in this asymmetric discharge will be enhanced gradually with increasing of the frequency until it makes the subsequent discharge weaken and results in the discharge entering a period-doubling state. In the whole transition process, the spatial distribution of the charged particle density and the electric field plays a definitive role. The conclusions are further confirmed by changing the gap width and the amplitude of the applied voltage.

  10. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  11. [Determination of electric field distribution in dielectric barrier surface glow discharge by spectroscopic method].

    Science.gov (United States)

    Li, Xue-chen; Jia, Peng-ying; Liu, Zhi-hui; Li, Li-chun; Dong, Li-fang

    2008-12-01

    In the present paper, stable glow discharges were obtained in air at low pressure with a dielectric barrier surface discharge device. Light emission from the discharge was detected by photomultiplier tubes and the research results show that the light signal exhibited one discharge pulse per half cycle of the applied voltage. The light pulses were asymmetric between the positive half cycle and the negative one of the applied voltage. The images of the glow surface discharge were processed by Photoshop software and the results indicate that the emission intensity remained almost constant for different places with the same distance from the powered electrode, while the emission intensity decreased with the distance from the powered electrode increasing. In dielectric barrier discharge, net electric field is determined by the applied voltage and the wall charges accumulated on the dielectric layer during the discharge, and consequently, it is important to obtain information about the net electric field distribution. For this purpose, optical emission spectroscopy method was used. The distribution of the net electric field can be deduced from the intensity ratio of spectral line 391.4 nm emitted from the first negative system of N2+ (B 2sigma u+ -->X 2sigma g+) to 337.1 nm emitted from the second positive system of N2 (C 3IIu-B 3IIg). The research results show that the electric field near the powered electric field is higher than at the edge of the discharge. These experimental results are very important for numerical study and industrial application of the surface discharge.

  12. Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

    Energy Technology Data Exchange (ETDEWEB)

    Gitlin, M. S., E-mail: gitlin@appl.sci-nnov.ru [Russian Academy of Sciences, Institute of Applied Physics (Russian Federation)

    2017-02-15

    The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

  13. Cesium ion exchange using actual waste: Column size considerations

    International Nuclear Information System (INIS)

    Brooks, K.P.

    1996-04-01

    It is presently planned to remove cesium from Hanford tank waste supernates and sludge wash solutions using ion exchange. To support the development of a cesium ion exchange process, laboratory experiments produced column breakthrough curves using wastes simulants in 200 mL columns. To verify the validity of the simulant tests, column runs with actual supernatants are being planned. The purpose of these actual waste tests is two-fold. First, the tests will verify that use of the simulant accurately reflects the equilibrium and rate behavior of the resin compared to actual wastes. Batch tests and column tests will be used to compare equilibrium behaviors and rate behaviors, respectively. Second, the tests will assist in clarifying the negative interactions between the actual waste and the ion exchange resin, which cannot be effectively tested with simulant. Such interactions include organic fouling of the resin and salt precipitation in the column. These effects may affect the shape of the column breakthrough curve. The reduction in column size also may change the shape of the curve, making the individual effects even more difficult to sort out. To simplify the evaluation, the changes due to column size must be either understood or eliminated. This report describes the determination of the column size for actual waste testing that best minimizes the effect of scale-down. This evaluation will provide a theoretical basis for the dimensions of the column. Experimental testing is still required before the final decision can be made. This evaluation will be confined to the study of CS-100 and R-F resins with NCAW simulant and to a limited extent DSSF waste simulant. Only the cesium loading phase has been considered

  14. Stability of embankments over cement deep soil mixing columns

    International Nuclear Information System (INIS)

    Morilla Moar, P.; Melentijevic, S.

    2014-01-01

    The deep soil mixing (DSM) is one of the ground improvement methods used for the construction of embankments over soft soils. DSM column-supported embankments are constructed over soft soils to accelerate its construction, improve embankment stability, increase bearing capacity and control of total and differential settlements. There are two traditional design methods, the Japanese (rigid columns) and the scandinavian (soft and semi-rigid columns). Based on Laboratory analysis and numerical analysis these traditional approaches have been questioned by several authors due to its overestimation of the embankment stability considering that the most common failures types are not assumed. This paper presents a brief review of traditional design methods for embankments on DSM columns constructed in soft soils, studies carried out determine the most likely failure types of DSM columns, methods to decrease the overestimation when using limit equilibrium methods and numerical analysis methods that permit detect appropriate failure modes in DSM columns. Finally a case study was assessed using both limited equilibrium and finite element methods which confirmed the overestimation in the factors of safety on embankment stability over DSM columns. (Author)

  15. Neutron fluence rate and energy spectrum in SPRR-300 reactor thermal column

    International Nuclear Information System (INIS)

    Dou Haifeng; Dai Junlong

    2006-01-01

    In order to modify the simple one-dimension model, the neutron fluence rate distribution calculated with ANISN code ws checked with that calculated with MCNP code. To modify the error caused by ignoring the neutron landscape orientation leaking, the reflector that can't be modeled in a simple one-dimension model was dealt by extending landscape orientation scale. On this condition the neutron fluence rate distribution and the energy spectrum in the thermal column of SPRR-300 reactor were calculated with one-dimensional code ANISN, and the results of Cd ratio are well accorded with the experimental results. The deviation between them is less than 5% and it isn't above 10% in one or two special positions. It indicates that neutron fluence rate distribution and energy spectrum in the thermal column can be well calculated with one-dimensional code ANISN. (authors)

  16. Vertebral Column Resection for Rigid Spinal Deformity.

    Science.gov (United States)

    Saifi, Comron; Laratta, Joseph L; Petridis, Petros; Shillingford, Jamal N; Lehman, Ronald A; Lenke, Lawrence G

    2017-05-01

    Broad narrative review. To review the evolution, operative technique, outcomes, and complications associated with posterior vertebral column resection. A literature review of posterior vertebral column resection was performed. The authors' surgical technique is outlined in detail. The authors' experience and the literature regarding vertebral column resection are discussed at length. Treatment of severe, rigid coronal and/or sagittal malalignment with posterior vertebral column resection results in approximately 50-70% correction depending on the type of deformity. Surgical site infection rates range from 2.9% to 9.7%. Transient and permanent neurologic injury rates range from 0% to 13.8% and 0% to 6.3%, respectively. Although there are significant variations in EBL throughout the literature, it can be minimized by utilizing tranexamic acid intraoperatively. The ability to correct a rigid deformity in the spine relies on osteotomies. Each osteotomy is associated with a particular magnitude of correction at a single level. Posterior vertebral column resection is the most powerful posterior osteotomy method providing a successful correction of fixed complex deformities. Despite meticulous surgical technique and precision, this robust osteotomy technique can be associated with significant morbidity even in the most experienced hands.

  17. Effect of backmixing on pulse column performance

    International Nuclear Information System (INIS)

    Miao, Y.W.

    1979-05-01

    A critical survey of the published literature concerning dispersed phase holdup and longitudinal mixing in pulsed sieve-plate extraction columns has been made to assess the present state-of-the-art in predicting these two parameters, both of which are of critical importance in the development of an accurate mathematical model of the pulse column. Although there are many conflicting correlations of these variables as a function of column geometry, operating conditions, and physical properties of the liquid systems involved it has been possible to develop new correlations which appear to be useful and which are consistent with much of the available data over the limited range of variables most likely to be encountered in plant sized equipment. The correlations developed were used in a stagewise model of the pulse column to predict product concentrations, solute inventory, and concentration profiles in a column for which limited experimental data were available. Reasonable agreement was obtained between the mathematical model and the experimental data. Complete agreement, however, can only be obtained after a correlation for the extraction efficiency has been developed. The correlation of extraction efficiency was beyond the scope of this work

  18. Hip fracture - discharge

    Science.gov (United States)

    ... neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge ... in the hospital for surgery to repair a hip fracture, a break in the upper part of ...

  19. First Directly Retrieved Global Distribution of Tropospheric Column Ozone from GOME: Comparison with the GEOS-CHEM Model

    Science.gov (United States)

    Liu, Xiong; Chance, Kelly; Sioris, Christopher E.; Kurosu, Thomas P.; Spurr, Robert J. D.; Martin, Randall V.; Fu, Tzung-May; Logan, Jennifer A.; Jacob, Daniel J.; Palmer, Paul I.; hide

    2006-01-01

    We present the first directly retrieved global distribution of tropospheric column ozone from Global Ozone Monitoring Experiment (GOME) ultraviolet measurements during December 1996 to November 1997. The retrievals clearly show signals due to convection, biomass burning, stratospheric influence, pollution, and transport. They are capable of capturing the spatiotemporal evolution of tropospheric column ozone in response to regional or short time-scale events such as the 1997-1998 El Nino event and a 10-20 DU change within a few days. The global distribution of tropospheric column ozone displays the well-known wave-1 pattern in the tropics, nearly zonal bands of enhanced tropospheric column ozone of 36-48 DU at 20degS-30degS during the austral spring and at 25degN-45degN during the boreal spring and summer, low tropospheric column ozone of 33 DU at some northern high-latitudes during the spring. Simulation from a chemical transport model corroborates most of the above structures, with small biases of <+/-5 DU and consistent seasonal cycles in most regions, especially in the southern hemisphere. However, significant positive biases of 5-20 DU occur in some northern tropical and subtropical regions such as the Middle East during summer. Comparison of GOME with monthly-averaged Measurement of Ozone and Water Vapor by Airbus in-service Aircraft (MOZAIC) tropospheric column ozone for these regions usually shows good consistency within 1 a standard deviations and retrieval uncertainties. Some biases can be accounted for by inadequate sensitivity to lower tropospheric ozone, the different spatiotemporal sampling and the spatiotemporal variations in tropospheric column ozone.

  20. Interaction diagrams for composite columns exposed to fire

    Directory of Open Access Journals (Sweden)

    Milanović Milivoje

    2014-01-01

    Full Text Available The bearing capacity of the cross section of composite column in fire conditions through changes in the interaction diagram 'bending moment-axialforce' were analyzed in this paper. The M-N interaction diagram presents the relationship between the intensities of the bending moment and the axial force as actions on the column cross section, or the relationship between the design value of the plastic resistance to axial compression of the total cross-section Npl, Rd and the design value of the bending moment resistance Mpl, Rd. It is well known that the temperature increase causes decrease of the load-bearing characteristics of the constitutive materials. This effect directly reflects on the reduction of the axial force and the bending moment that could be accepted by the column cross section. Interaction diagrams for three different types of column cross sections for five different maximal temperatures developed during the fire action were defined. For that purpose the software package SAFIR was used. The columns, materials and load characteristics, as well as all other terms and conditions, were taken in accordance with the relevant Eurocodes and the theory of composite columns.

  1. Recovery of deuterium from H-D gas mixture by thermal diffusion in a multi-concentric-tube column device of fixed total sum of column heights with transverse sampling streams

    International Nuclear Information System (INIS)

    Yeh, H.-M.

    2010-01-01

    The effect of the increment in the number of concentric-tube thermal diffusion columns on the recovery of deuterium from H 2 -HD-D 2 system with fixed total sum of column heights, has been investigated. The equations for predicting the degrees of separation in single-column, double-column and triple-column devices have been derived. Considerable improvement in recovery can be achieved if a multi-column device with larger number of column is employed, instead of a single-column device with column height equal to the same total sum of column heights, especially for the case of higher flow-rate operation and larger total sum of column heights.

  2. The cat vertebral column: stance configuration and range of motion

    Science.gov (United States)

    Macpherson, J. M.; Ye, Y.; Peterson, B. W. (Principal Investigator)

    1998-01-01

    This study examined the configuration of the vertebral column of the cat during independent stance and in various flexed positions. The range of motion in the sagittal plane is similar across most thoracic and lumbar joints, with the exception of a lesser range at the transition region from thoracic-type to lumbar-type vertebrae. The upper thoracic column exhibits most of its range in dorsiflexion and the lower thoracic and lumbar in ventroflexion. Lateral flexion is limited to less than 5 degrees at all segments. The range in torsion is almost 180 degrees and occurs primarily in the midthoracic region, T4-T11. Contrary to the depiction in most atlases, the standing cat exhibits several curvatures, including a mild dorsiflexion in the lower lumbar segments, a marked ventroflexion in the lower thoracic and upper lumbar segments, and a profound dorsiflexion in the upper thoracic (above T9) and cervical segments. The curvatures are not significantly changed by altering stance distance but are affected by head posture. During stance, the top of the scapula lies well above the spines of the thoracic vertebrae, and the glenohumeral joint is just below the bodies of vertebrae T3-T5. Using a simple static model of the vertebral column in the sagittal plane, it was estimated that the bending moment due to gravity is bimodal with a dorsiflexion moment in the lower thoracic and lumbar region and a ventroflexion moment in the upper thoracic and cervical region. Given the bending moments and the position of the scapula during stance, it is proposed that two groups of scapular muscles provide the major antigravity support for the head and anterior trunk. Levator scapulae and serratus ventralis form the lateral group, inserting on the lateral processes of cervical vertebrae and on the ribs. The major and minor rhomboids form the medial group, inserting on the spinous tips of vertebrae from C4 to T4. It is also proposed that the hypaxial muscles, psoas major, minor, and quadratus

  3. Spatial-temporal evolution of self-organized loop-patterns on a water surface and a diffuse discharge in the gap

    Science.gov (United States)

    Li, Xuechen; Geng, Jinling; Jia, Pengying; Zhang, Panpan; Zhang, Qi; Li, Yaru

    2017-11-01

    Excited by an alternating current voltage, a patterned discharge and a diffuse discharge are generated in a needle to liquid configuration. Using an intensified charge-coupled device (ICCD), temporal evolution of the discharge between the two electrodes is investigated for the diffuse mode and the patterned mode, respectively. For the diffuse mode, the positive discharge is in a glow regime, and the negative discharge is in a Townsend discharge regime. For the patterned mode, the discharge always belongs to the Townsend discharge regime. Moreover, in the patterned mode, various patterns including the single loop, single loop with the surrounding corona, triple loops, and concentric loops with a central spot are observed on the water surface with the increasing positive peak-value of the applied voltage (Upp). Temporally resolved images of the loop-patterns are captured on the water surface. From the electrical measurements and the ICCD imaging, it is found that the loop pattern emerges after the discharge bridges the two electrodes. Then, it begins to evolve and finally degenerates with the decrease in the discharge current. The pattern does not disappear until the discharge quenches. Formation of the loop-patterns is attributed to the role of negative ions.

  4. Enrichment of heavy water in thermal-diffusion columns connected in series

    International Nuclear Information System (INIS)

    Yeh, Ho-Ming; Chen, Liu Yi

    2009-01-01

    The separation equations for enrichment of heavy water from water isotope mixture by thermal diffusion in multiple columns connected in series, have been derived based on one column design developed in previous work. The improvement in separation is achievable by operating in a double-column device, instead of in a single-column device, with the same total column length. It is also found that further improvement in separation is obtainable if a triple-column device is employed, except for operating under small total column length and low flow rate.

  5. Multi-Column Experimental Test Bed for Xe/Kr Separation

    International Nuclear Information System (INIS)

    Greenhalgh, Mitchell Randy; Garn, Troy Gerry; Welty, Amy Keil; Lyon, Kevin Lawrence; Watson, Tony Leroy

    2015-01-01

    Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both

  6. The relationship between inpatient discharge timing and emergency department boarding.

    Science.gov (United States)

    Powell, Emilie S; Khare, Rahul K; Venkatesh, Arjun K; Van Roo, Ben D; Adams, James G; Reinhardt, Gilles

    2012-02-01

    Patient crowding and boarding in Emergency Departments (EDs) impair the quality of care as well as patient safety and satisfaction. Improved timing of inpatient discharges could positively affect ED boarding, and this hypothesis can be tested with computer modeling. Modeling enables analysis of the impact of inpatient discharge timing on ED boarding. Three policies were tested: a sensitivity analysis on shifting the timing of current discharge practices earlier; discharging 75% of inpatients by 12:00 noon; and discharging all inpatients between 8:00 a.m. and 4:00 p.m. A cross-sectional computer modeling analysis was conducted of inpatient admissions and discharges on weekdays in September 2007. A model of patient flow streams into and out of inpatient beds with an output of ED admitted patient boarding hours was created to analyze the three policies. A mean of 38.8 ED patients, 22.7 surgical patients, and 19.5 intensive care unit transfers were admitted to inpatient beds, and 81.1 inpatients were discharged daily on September 2007 weekdays: 70.5%, 85.6%, 82.8%, and 88.0%, respectively, occurred between noon and midnight. In the model base case, total daily admitted patient boarding hours were 77.0 per day; the sensitivity analysis showed that shifting the peak inpatient discharge time 4h earlier eliminated ED boarding, and discharging 75% of inpatients by noon and discharging all inpatients between 8:00 a.m. and 4:00 p.m. both decreased boarding hours to 3.0. Timing of inpatient discharges had an impact on the need to board admitted patients. This model demonstrates the potential to reduce or eliminate ED boarding by improving inpatient discharge timing in anticipation of the daily surge in ED demand for inpatient beds. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Convolutional Codes with Maximum Column Sum Rank for Network Streaming

    OpenAIRE

    Mahmood, Rafid; Badr, Ahmed; Khisti, Ashish

    2015-01-01

    The column Hamming distance of a convolutional code determines the error correction capability when streaming over a class of packet erasure channels. We introduce a metric known as the column sum rank, that parallels column Hamming distance when streaming over a network with link failures. We prove rank analogues of several known column Hamming distance properties and introduce a new family of convolutional codes that maximize the column sum rank up to the code memory. Our construction invol...

  8. Travelling-wave-sustained discharges

    International Nuclear Information System (INIS)

    Schlueter, Hans; Shivarova, Antonia

    2007-01-01

    This review is on discharges maintained by travelling waves: new plasma sources, discovered in 1974 and considered as a prototype of the gas discharges according to their definition as nonlinear systems which unify in a self-consistent manner plasmas and fields. In the presentation here of the fluid-plasma models of the diffusion-controlled regime of the travelling-wave-sustained discharges (TWSDs), the basic features of the discharge maintenance-the discharge self-consistency and the electron heating in the high-frequency field-are stressed. Operation of stationary and pulsed discharges, discharge maintenance without and in external magnetic fields as well as discharge production in different gases (argon, helium, helium-argon gas mixtures and hydrogen) are covered. Modulation instability of diffusion-controlled discharges and discharge filamentation at higher gas pressures are also included in the review. Experimental findings which motivate aspects of the reported modelling are pointed out

  9. Control of plasma position in the CASTOR tokamak

    International Nuclear Information System (INIS)

    Valovic, M.

    1988-11-01

    A simple servo-system designed for plasma position control in the CASTOR tokamak is described. Both radial and vertical plasma displacements were minimized using two servo-loops consisting of detection coils, a conventional electric controller and an amplifier operated as an unipolar voltage-controlled current source. To ensure the optimum conditions in the start-up phase of the discharge, currents in the servo-systems were externally preprogrammed. The prescribed plasma position was maintained with the accuracy of 3 mm. The feedback control improves plasma parameters, e.g. it removes the positional disruption at the end of the tokamak discharge. (J.U.). 4 figs., 3 refs

  10. Experiments on Ion-Ion Plasmas From Discharges

    Science.gov (United States)

    Leonhardt, Darrin; Walton, Scott; Blackwell, David; Murphy, Donald; Fernsler, Richard; Meger, Robert

    2001-10-01

    Use of both positive and negative ions in plasma processing of materials has been shown to be advantageous[1] in terms of better feature evolution and control. In this presentation, experimental results are given to complement recent theoretical work[2] at NRL on the formation and decay of pulsed ion-ion plasmas in electron beam generated discharges. Temporally resolved Langmuir probe and mass spectrometry are used to investigate electron beam generated discharges during the beam on (active) and off (afterglow) phases in a variety of gas mixtures. Because electron-beam generated discharges inherently[3] have low electron temperatures (<0.5eV in molecular gases), negative ion characteristics are seen in the active as well as afterglow phases since electron detachment increases with low electron temperatures. Analysis of temporally resolved plasma characteristics deduced from these measurements will be presented for pure O_2, N2 and Ar and their mixtures with SF_6. Oxygen discharges show no noticeable negative ion contribution during the active or afterglow phase, presumably due to the higher energy electron attachment threshold, which is well above any electron temperature. In contrast, SF6 discharges demonstrate ion-ion plasma characteristics in the active glow and are completely ion-ion in the afterglow. Comparison between these discharges with published cross sections and production mechanisms will also be presented. [1] T.H. Ahn, K. Nakamura & H. Sugai, Plasma Sources Sci. Technol., 5, 139 (1996); T. Shibyama, H. Shindo & Y. Horiike, Plasma Sources Sci. Technol., 5, 254 (1996). [2] See presentation by R. F. Fernsler, at this conference. [3] D. Leonhardt, et al., 53rd Annual GEC, Houston, TX.

  11. Older veterans and emergency department discharge information.

    Science.gov (United States)

    Hastings, Susan; Stechuchak, Karen; Oddone, Eugene; Weinberger, Morris; Tucker, Dana; Knaack, William; Schmader, Kenneth

    2012-10-01

    Study goals were to assess older veterans' understanding of their emergency department (ED) discharge information and to determine the association between understanding discharge information and patient assessment of overall quality of care. Telephone interviews were conducted with 305 patients aged 65 or older (or their proxies) within 48 h of discharge from a Veterans Affairs Medical Center ED. Patients were asked about their perceived understanding (at the time of ED discharge) of information about their ED diagnosis, expected course of illness, contingency plan (ie, return precautions, who to call if it got worse, potential medication side effects) and follow-up care. Overall quality of ED care was rated on a four-point scale of poor, fair, good or excellent. Patients or their proxies reported not understanding information about their ED diagnosis (21%), expected course of illness (50%), contingency plan (43%), and how soon they needed to follow-up with their primary care provider (25%). In models adjusted for age and race, a positive association was observed between perceived understanding of the cause of the problem (OR 2.3; 95% CI 1.3 to 4.0), expected duration of symptoms (OR 1.6; 95% CI 1.0 to 2.5) and the contingency plan (OR 2.2; CI 1.3 to 3.4), and rating overall ED care as excellent. Older veterans may not understand key items of information at the time ED discharge, and this may have an impact on how they view the quality of ED care. Strategies are needed to improve communication of ED discharge information to older veterans and their families.

  12. Ankle replacement - discharge

    Science.gov (United States)

    ... total - discharge; Total ankle arthroplasty - discharge; Endoprosthetic ankle replacement - discharge; Osteoarthritis - ankle ... You had an ankle replacement. Your surgeon removed and reshaped ... an artificial ankle joint. You received pain medicine and were ...

  13. Asthma - child - discharge

    Science.gov (United States)

    Pediatric asthma - discharge; Wheezing - discharge; Reactive airway disease - discharge ... Your child has asthma , which causes the airways of the lungs to swell and narrow. In the hospital, the doctors and nurses helped ...

  14. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  15. Diagnostics of a negative hydrogen ion source based on a planar-coil inductively-driven discharge

    International Nuclear Information System (INIS)

    Lishev, Stiliyan St.; Shivarova, Antonia P.; Iordanov, Dimitar I.; Todorov, Dimitar T.; Demerdzhiev, Angel P.

    2013-01-01

    Recent activity on a volume-production negative-hydrogen-ion source with the design of a matrix of small-radius discharges inductively driven by a planar coil is reported. A single discharge of the matrix has been studied by employing probe-and laser-photodetachment diagnostics. The measurements have been carried out in the first - small-size - chamber of a two-chamber discharge vessel, with rf power introduced by a planar coil positioned on its front wall. The measured profiles of the negative ion density show strong axial dependence, with two maxima located at the positions corresponding to the maxima of the dc potential, where the maxima of the electron density are also located. The first maximum is in the vicinity of the rf power input and the second one is close to the interface between the two chambers of the discharge vessel.

  16. Equilibrium and stability of a toroidal-sector plasma discharge in an EXTRAP configuration

    International Nuclear Information System (INIS)

    Drake, J.R.

    1982-02-01

    Experimental studies of the equilibrium and stability of a sector of a toroidal EXTRAP plasma discharge have been studied. The high β plasma discharge, which had an Alfven transit time about 0.5 μsec, could be positioned in a stable equilibrium for the 300μsec time scale of the experiment. (author)

  17. Production mechanism of negative pionlike particles in H2 gas discharge plasma

    International Nuclear Information System (INIS)

    Uramoto, Joshin.

    1996-04-01

    Negative pionlike and muonlike particles are produced by an electron bunch and a positive ion bunch which are generated controllably from an electron beam and a gas. Physical characteristics of the negative pionlike particles are the same with those of negative pionlike particles extracted from the H 2 gas discharge. Thus, the production mechanism in the H 2 gas discharge is deduced. (author)

  18. Epidemiology and clinico-investigative study of organisms causing vaginal discharge

    Science.gov (United States)

    Venugopal, Swetha; Gopalan, Kannan; Devi, Asha; Kavitha, A.

    2017-01-01

    Background: Abnormal vaginal discharge is a common clinical problem in reproductive age group. It is the second most common problem after abnormal uterine bleeding. It is a neglected health problem, most commonly caused due to vulvovaginal candidiasis, trichomoniasis, and bacterial vaginosis (BV). Objectives: The present study was conducted to determine the prevalence of common organisms causing vaginal discharge and also to know the variety of clinical presentation. Materials and Methods: A cross-sectional descriptive study was conducted in the Skin and STD Outpatient Department of Vinayaka Mission Kirupananda Variyar Medical College Hospital, Salem, who presented with abnormal vaginal discharge between September 2012 and September 2014. A total of 100 women in the reproductive age group who had symptoms of vaginitis were examined. Data were coded and analyzed. Results: Out of the 100 patients examined, 77 (77%) cases were organism positive. Among the positive cases, BV (27%) was the most common microbiological cause of abnormal vaginal discharge, followed by trichomoniasis (25%), vaginal candidiasis (22%), combined infection (Candida and BV) (3%), and nonspecific cases (23%). Conclusion: Out of 100 cases, few cases showed discordance between clinical and laboratory diagnosis. This discordance can be due to pitfalls in identifying the causative agent clinically or obscuring of the findings due to improper treatment received for other ailments. Thus, clinico-investigative correlation is more important than other clinical findings alone. PMID:28442807

  19. Experimental Investigation – Magnetic Assisted Electro Discharge Machining

    Science.gov (United States)

    Kesava Reddy, Chirra; Manzoor Hussain, M.; Satyanarayana, S.; Krishna, M. V. S. Murali

    2018-04-01

    Emerging technology needs advanced machined parts with high strength and temperature resistance, high fatigue life at low production cost with good surface quality to fit into various industrial applications. Electro discharge machine is one of the extensively used machines to manufacture advanced machined parts which cannot be machined by other traditional machine with high precision and accuracy. Machining of DIN 17350-1.2080 (High Carbon High Chromium steel), using electro discharge machining has been discussed in this paper. In the present investigation an effort is made to use permanent magnet at various positions near the spark zone to improve surface quality of the machined surface. Taguchi methodology is used to obtain optimal choice for each machining parameter such as peak current, pulse duration, gap voltage and Servo reference voltage etc. Process parameters have significant influence on machining characteristics and surface finish. Improvement in surface finish is observed when process parameters are set at optimum condition under the influence of magnetic field at various positions.

  20. Acoustic position finding of partial discharges in transformers. Combination of partial discharge measurement technology with 3D visualization; Akustische Ortung von Teilentladungen in Transformatoren. TE-Messtechnik und 3-D-Visualisierung kombiniert

    Energy Technology Data Exchange (ETDEWEB)

    Kraetge, Alexander; Hoek, Stefan [Omicron Electronics GmbH, Klaus (Austria)

    2013-11-01

    A new measuring system facilitates the detection of partial discharges in transformers by means of the fully synchronous combination of measurement technology for electrical partial discharges with intuitive 3D visualization of the test object. The contribution under consideration describes the application of this system with examples from the measurement practice.

  1. Stress-Strain Relationship of Synthetic Fiber Reinforced Concrete Columns

    Directory of Open Access Journals (Sweden)

    Rosidawani

    2017-01-01

    Full Text Available Many empirical confinement models for normal and high strength concrete have been developed. Nevertheless, reported studies in the term of confinement of fiber reinforced concrete are limited. Whereas, the use of fiber reinforced concrete in structural elements has become the subject of the research and has indicated positive experiences. Since the stress-strain relationship of concrete in compression is required for analysis of structural members, the study of the stress-strain relationship for synthetic fiber reinforced concrete is substantial. The aim of the study is to examine the capabilities of the various models available in the literature to predict the actual experimental behavior of synthetic fiber reinforced high-strength concrete columns. The experimental data used are the results of the circular column specimens with the spiral spacing and the volume fraction of synthetic fiber as the test variables. The axial stress-strain curves from the tests are then compared with the various models of confinement from the literature. The performance index of each model is measured by using the coefficient of variation (COV concept of stress and strain behavior parameter. Among the confinement models, Cusson model shows the closest valid value of the coefficient of variation.

  2. Low-dielectric layer increases nanosecond electric discharges in distilled water

    KAUST Repository

    Hamdan, Ahmad

    2016-10-24

    Electric discharge in liquids is an emerging field of research, and is involved into various environmental applications (water purification, fuel reforming, nanomaterial synthesis, etc.). Increasing the treatment efficiency with simultaneous decreasing of the energy consumption are the main goals of today’s research. Here we present an experimental study of nanosecond discharge in distilled water covered by a layer of dielectric material. We demonstrate through this paper that the discharge efficiency can be improved by changing the interface position regarding the anode tip. The efficiency increase is due to the increase of the discharge probability as well as the plasma volume. The understanding of the experimental results is brought and strengthened by simulating the electric field distribution, using Comsol Multiphysics software. Because the dielectric permittivity (ε) is discontinuous at the interface, the electric field is enhanced by a factor that depends on the relative value of ε of the two liquids. The present result is very promising in future: opportunities for potential applications as well as fundamental studies for discharges in liquid.

  3. Discharge and infection in retinoblastoma post-enucleation sockets.

    Science.gov (United States)

    Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C

    2017-01-01

    To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients' characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients ( P socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which local antibiotic treatment seemed effective in most cases.

  4. Modelling of the initial stage of the surface discharge development

    International Nuclear Information System (INIS)

    Gibalov, V.; Pietsch, G.

    1998-01-01

    Computer modelling of the initial stage of the surface discharge was performed by solving numerically the coupled continuity, the Poisson and Townsend ionization equations and taking into account the ionization, attachment and detachment processes. The potential distribution at the dielectric surface and at the boundaries which surround the integration region have been calculated with the charge-image method in a 3D approach. In order to eliminate numerical diffusion effects, the solution of the continuity equation was corrected using a flux correction transport routine. At the positive voltage the development of the discharge channel is determined mainly by the shape of the electrode tip. At the negative voltage the following phases of the discharge may be distinguished: the initial phase, the cathode directed streamer phase resulting in the cathode layer formation, and the propagating phase. The physical processes governing each discharge phase are described in detail. (J.U.)

  5. Particle balance under global wall saturation in long-pulse discharges of JT-60U

    International Nuclear Information System (INIS)

    Nakano, T.; Asakura, N.; Takenaga, H.; Kubo, H.; Shimizu, K.; Kawashima, H.

    2007-01-01

    During 30s-ELMy H-mode discharges, the wall-pumping rate decreases with a decay constant of several seconds and then becomes constant. During the constant wall-pumping phase, in discharges with a density of 65% of the Greenwald density, the wall-pumping rate is negative, in other words, outgassing. It has been found that this outgassing rate correlates with an increase in the tile temperature around the outer strike point. In discharges with a density of 80% of the Greenwald density, the wall-pumping rate is positive. Unless a high net deposition rate (>60%) of hydrocarbon is assumed, the positive wall-pumping rate cannot be explained only by the co-deposition of deuterium with carbon even if the outgassing rate is assumed to be zero. The vessel deuterium inventory decreases by 1.1 x 10 24 on one experimental day with 17 long discharges. The main chamber wall is suggested as the deuterium source for the decrease of the inventory

  6. Permanent magnet finger-size scanning electron microscope columns

    Energy Technology Data Exchange (ETDEWEB)

    Nelliyan, K., E-mail: elenk@nus.edu.sg [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore)

    2011-07-21

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  7. Permanent magnet finger-size scanning electron microscope columns

    International Nuclear Information System (INIS)

    Nelliyan, K.; Khursheed, A.

    2011-01-01

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  8. Dynamic effects on cyclotron scattering in pulsar accretion columns

    International Nuclear Information System (INIS)

    Brainerd, J.J.; Meszaros, P.

    1991-01-01

    A resonant scattering model for photon reprocessing in a pulsar accretion column is presented. The accretion column is optically thin to Thomson scattering and optically thick to resonant scattering at the cyclotron frequency. Radiation from the neutron star surface propagates freely through the column until the photon energy equals the local cyclotron frequency, at which point the radiation is scattered, much of it back toward the star. The radiation pressure in this regime is insufficient to stop the infall. Some of the scattered radiation heats the stellar surface around the base of the column, which adds a softer component to the spectrum. The partial blocking by the accretion column of X-rays from the surface produces a fan beam emission pattern. X-rays above the surface cyclotron frequency freely escape and are characterized by a pencil beam. Gravitational light bending produces a pencil beam pattern of column-scattered radiation in the antipodal direction, resulting in a strongly angle-dependent cyclotron feature. 31 refs

  9. Aspartic acid incorporated monolithic columns for affinity glycoprotein purification.

    Science.gov (United States)

    Armutcu, Canan; Bereli, Nilay; Bayram, Engin; Uzun, Lokman; Say, Rıdvan; Denizli, Adil

    2014-02-01

    Novel aspartic acid incorporated monolithic columns were prepared to efficiently affinity purify immunoglobulin G (IgG) from human plasma. The monolithic columns were synthesised in a stainless steel HPLC column (20 cm × 5 mm id) by in situ bulk polymerisation of N-methacryloyl-L-aspartic acid (MAAsp), a polymerisable derivative of L-aspartic acid, and 2-hydroxyethyl methacrylate (HEMA). Monolithic columns [poly(2-hydroxyethyl methacrylate-N-methacryloyl-L-aspartic acid) (PHEMAsp)] were characterised by swelling studies, Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The monolithic columns were used for IgG adsorption/desorption from aqueous solutions and human plasma. The IgG adsorption depended on the buffer type, and the maximum IgG adsorption from aqueous solution in phosphate buffer was 0.085 mg/g at pH 6.0. The monolithic columns allowed for one-step IgG purification with a negligible capacity decrease after ten adsorption-desorption cycles. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  11. Large scale Tesla coil guided discharges initiated by femtosecond laser filamentation in air

    Science.gov (United States)

    Arantchouk, L.; Point, G.; Brelet, Y.; Prade, B.; Carbonnel, J.; André, Y.-B.; Mysyrowicz, A.; Houard, A.

    2014-07-01

    The guiding of meter scale electric discharges produced in air by a Tesla coil is realized in laboratory using a focused terawatt laser pulse undergoing filamentation. The influence of the focus position, the laser arrival time, or the gap length is studied to determine the best conditions for efficient laser guiding. Discharge parameters such as delay, jitter, and resistance are characterized. An increase of the discharge length by a factor 5 has been achieved with the laser filaments, corresponding to a mean breakdown field of 2 kV/cm for a 1.8 m gap length. Consecutive guided discharges at a repetition rate of 10 Hz are also reported.

  12. Hydrogen peroxide stabilization in one-dimensional flow columns

    Science.gov (United States)

    Schmidt, Jeremy T.; Ahmad, Mushtaque; Teel, Amy L.; Watts, Richard J.

    2011-09-01

    Rapid hydrogen peroxide decomposition is the primary limitation of catalyzed H 2O 2 propagations in situ chemical oxidation (CHP ISCO) remediation of the subsurface. Two stabilizers of hydrogen peroxide, citrate and phytate, were investigated for their effectiveness in one-dimensional columns of iron oxide-coated and manganese oxide-coated sand. Hydrogen peroxide (5%) with and without 25 mM citrate or phytate was applied to the columns and samples were collected at 8 ports spaced 13 cm apart. Citrate was not an effective stabilizer for hydrogen peroxide in iron-coated sand; however, phytate was highly effective, increasing hydrogen peroxide residuals two orders of magnitude over unstabilized hydrogen peroxide. Both citrate and phytate were effective stabilizers for manganese-coated sand, increasing hydrogen peroxide residuals by four-fold over unstabilized hydrogen peroxide. Phytate and citrate did not degrade and were not retarded in the sand columns; furthermore, the addition of the stabilizers increased column flow rates relative to unstabilized columns. These results demonstrate that citrate and phytate are effective stabilizers of hydrogen peroxide under the dynamic conditions of one-dimensional columns, and suggest that citrate and phytate can be added to hydrogen peroxide before injection to the subsurface as an effective means for increasing the radius of influence of CHP ISCO.

  13. Behavior of hard X-ray emission in discharges with current disruptions in the DAMAVAND and TVD tokamaks

    International Nuclear Information System (INIS)

    Farshi, E.; Amrollahy, R.; Bortnikov, A.V.; Brevnov, N.N.; Gott, Yu.V.; Shurygin, V.A.

    2001-01-01

    Results are presented from studies of the behavior of hard X-ray emission in discharges with current disruptions in the DAMAVAND and TVD tokamaks. The current disruptions are caused by either an MHD instability or the instability related to the vertical displacement of the plasma column. Experiments were conducted at a fixed value of the safety factor at the plasma boundary (q a ≅ 2.3). Experimental data show that, during a disruption caused by an MHD instability, hard X-ray emission is suppressed by this instability if the amplitude of the magnetic field fluctuations exceeds a certain level. If the disruption is caused by the instability related to the vertical displacement of the plasma column, then hard X-ray emission is observed at the instant of disruption. The experimental results show that the physical processes resulting in the generation and suppression of runaway electron beams are almost identical in large and small tokamaks

  14. Influence of the capillary on the ignition of the transient spark discharge

    International Nuclear Information System (INIS)

    Gerling, T; Hoder, T; Brandenburg, R; Bussiahn, R; Weltmann, K-D

    2013-01-01

    A self-pulsing negative dc discharge in argon generated in a needle-to-plane geometry at open atmosphere is investigated. Additionally, the needle electrode can be surrounded by a quartz capillary. It is shown that the relative position of the capillary end to the needle tip strongly influences the discharge inception and its spatio-temporal dynamics. Without the capillary for the selected working parameters a streamer corona is ignited, but when the capillary surrounds the needle, the transient spark (TS) discharge is ignited after a pre-streamer (PS) occurs. The time between PS and TS discharge depends on the relative capillary end position. The existence of the PS is confirmed by electro-optical characterization. Furthermore, spectrally and spatio-temporally resolved cross-correlation spectroscopy is applied to show the most active region of pre-phase emission activity as indicators for high local electric field strength. The results indicate that with a capillary in place, the necessary energy input of the pre-phase into the system is mainly reduced by additional electrical fields at the capillary edge. Even such a small change as a shift of dielectric surface close to the plasma largely changes the energy balance in the system. (paper)

  15. Mathematical modeling of alcohol distillation columns

    Directory of Open Access Journals (Sweden)

    Ones Osney Pérez

    2011-04-01

    Full Text Available New evaluation modules are proposed to extend the scope of a modular simulator oriented to the sugar cane industry, called STA 4.0, in a way that it can be used to carry out x calculation and analysis in ethanol distilleries. Calculation modules were developed for the simulation of the columns that are combined in the distillation area. Mathematical models were supported on materials and energy balances, equilibrium relations and thermodynamic properties of the ethanol-water system. Ponchon-Savarit method was used for the evaluation of the theoretical stages in the columns. A comparison between the results using Ponchon- Savarit method and those obtained applying McCabe-Thiele method was done for a distillation column. These calculation modules for ethanol distilleries were applied to a real case for validation.

  16. Hollow-Core FRP–Concrete–Steel Bridge Columns under Torsional Loading

    Directory of Open Access Journals (Sweden)

    Sujith Anumolu

    2017-11-01

    Full Text Available This paper presents the behavior of hollow-core fiber-reinforced polymer–concrete–steel (HC-FCS columns under cyclic torsional loading combined with constant axial load. The HC-FCS consists of an outer fiber-reinforced polymer (FRP tube and an inner steel tube, with a concrete shell sandwiched between the two tubes. The FRP tube was stopped at the surface of the footing, and provided confinement to the concrete shell from the outer direction. The steel tube was embedded into the footing to a length of 1.8 times the diameter of the steel tube. The longitudinal and transversal reinforcements of the column were provided by the steel tube only. A large-scale HC-FCS column with a diameter of 24 in. (610 mm and applied load height of 96 in. (2438 mm with an aspect ratio of four was investigated during this study. The study revealed that the torsional behavior of the HC-FCS column mainly depended on the stiffness of the steel tube and the interactions among the column components (concrete shell, steel tube, and FRP tube. A brief comparison of torsional behavior was made between the conventional reinforced concrete columns and the HC-FCS column. The comparison illustrated that both column types showed high initial stiffness under torsional loading. However, the HC-FCS column maintained the torsion strength until a high twist angle, while the conventional reinforced concrete column did not.

  17. Which processes drive observed variations of HCHO columns over India?

    Science.gov (United States)

    Surl, Luke; Palmer, Paul I.; González Abad, Gonzalo

    2018-04-01

    We interpret HCHO column variations observed by the Ozone Monitoring Instrument (OMI), aboard the NASA Aura satellite, over India during 2014 using the GEOS-Chem atmospheric chemistry and transport model. We use a nested version of the model with a horizontal resolution of approximately 25 km. HCHO columns are related to local emissions of volatile organic compounds (VOCs) with a spatial smearing that increases with the VOC lifetime. Over India, HCHO has biogenic, pyrogenic, and anthropogenic VOC sources. Using a 0-D photochemistry model, we find that isoprene has the largest molar yield of HCHO which is typically realized within a few hours. We also find that forested regions that neighbour major urban conurbations are exposed to high levels of nitrogen oxides. This results in depleted hydroxyl radical concentrations and a delay in the production of HCHO from isoprene oxidation. We find that propene is the only anthropogenic VOC emitted in major Indian cities that produces HCHO at a comparable (but slower) rate to isoprene. The GEOS-Chem model reproduces the broad-scale annual mean HCHO column distribution observed by OMI (r = 0.6), which is dominated by a distinctive meridional gradient in the northern half of the country, and by localized regions of high columns that coincide with forests. Major discrepancies are noted over the Indo-Gangetic Plain (IGP) and Delhi. We find that the model has more skill at reproducing observations during winter (JF) and pre-monsoon (MAM) months with Pearson correlations r > 0.5 but with a positive model bias of x≃1×1015 molec cm-2. During the monsoon season (JJAS) we reproduce only a diffuse version of the observed meridional gradient (r = 0.4). We find that on a continental scale most of the HCHO column seasonal cycle is explained by monthly variations in surface temperature (r = 0.9), suggesting a role for biogenic VOCs, in agreement with the 0-D and GEOS-Chem model calculations. We also find that the seasonal cycle during

  18. The general packed column : an analytical solution

    NARCIS (Netherlands)

    Gielen, J.L.W.

    2000-01-01

    The transient behaviour of a packed column is considered. The column, uniformly packed on a macroscopic scale, is multi-structured on the microscopic level: the solid phase consists of particles, which may differ in incidence, shape or size, and other relevant physical properties. Transport in the

  19. Pediatric heart surgery - discharge

    Science.gov (United States)

    ... discharge; Heart valve surgery - children - discharge; Heart surgery - pediatric - discharge; Heart transplant - pediatric - discharge ... Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016:chap 434. ...

  20. Revised Thermal Analysis of LANL Ion Exchange Column

    Energy Technology Data Exchange (ETDEWEB)

    Laurinat, J

    2006-04-11

    This document updates a previous calculation of the temperature distributions in a Los Alamos National Laboratory (LANL) ion exchange column.1 LANL operates two laboratory-scale anion exchange columns, in series, to extract Pu-238 from nitric acid solutions. The Defense Nuclear Facilities Safety Board has requested an updated analysis to calculate maximum temperatures for higher resin loading capacities obtained with a new formulation of the Reillex HPQ anion exchange resin. The increased resin loading capacity will not exceed 118 g plutonium per L of resin bed. Calculations were requested for normal operation of the resin bed at the minimum allowable solution feed rate of 30 mL/min and after an interruption of flow at the end of the feed stage, when one of the columns is fully loaded. The object of the analysis is to demonstrate that the decay heat from the Pu-238 will not cause resin bed temperatures to increase to a level where the resin significantly degrades. At low temperatures, resin bed temperatures increase primarily due to decay heat. At {approx}70 C a Low Temperature Exotherm (LTE) resulting from the reaction between 8-12 M HNO{sub 3} and the resin has been observed. The LTE has been attributed to an irreversible oxidation of pendant ethyl benzene groups at the termini of the resin polymer chains by nitric acid. The ethyl benzene groups are converted to benzoic acid moities. The resin can be treated to permanently remove the LTE by heating a resin suspension in 8M HNO{sub 3} for 30-45 minutes. No degradation of the resin performance is observed after the LTE removal treatment. In fact, heating the resin in boiling ({approx}115-120 C) 12 M HNO{sub 3} for 3 hr displays thermal stability analogous to resin that has been treated to remove the LTE. The analysis is based on a previous study of the SRS Frames Waste Recovery (FWR) column, performed in support of the Pu-238 production campaign for NASA's Cassini mission. In that study, temperature transients

  1. Dopamine-imprinted monolithic column for capillary electrochromatography.

    Science.gov (United States)

    Aşır, Süleyman; Sarı, Duygu; Derazshamshir, Ali; Yılmaz, Fatma; Şarkaya, Koray; Denizli, Adil

    2017-11-01

    A dopamine-imprinted monolithic column was prepared and used in capillary electrochromatography as stationary phase for the first time. Dopamine was selectively separated from aqueous solution containing the competitor molecule norepinephrine, which is similar in size and shape to the template molecule. Morphology of the dopamine-imprinted column was observed by scanning electron microscopy. The influence of the organic solvent content of mobile phase, applied pressure and pH of the mobile phase on the recognition of dopamine by the imprinted monolithic column has been evaluated, and the imprinting effect in the dopamine-imprinted monolithic polymer was verified. Developed dopamine-imprinted monolithic column resulted in excellent separation of dopamine from structurally related competitor molecule, norepinephrine. Separation was achieved in a short period of 10 min, with the electrophoretic mobility of 5.81 × 10 -5  m 2 V -1 s -1 at pH 5.0 and 500 mbar pressure. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Properties of water surface discharge at different pulse repetition rates

    International Nuclear Information System (INIS)

    Ruma,; Yoshihara, K.; Hosseini, S. H. R.; Sakugawa, T.; Akiyama, H.; Akiyama, M.; Lukeš, P.

    2014-01-01

    The properties of water surface discharge plasma for variety of pulse repetition rates are investigated. A magnetic pulse compression (MPC) pulsed power modulator able to deliver pulse repetition rates up to 1000 Hz, with 0.5 J per pulse energy output at 25 kV, was used as the pulsed power source. Positive pulse with a point-to-plane electrode configuration was used for the experiments. The concentration and production yield of hydrogen peroxide (H 2 O 2 ) were quantitatively measured and orange II organic dye was treated, to evaluate the chemical properties of the discharge reactor. Experimental results show that the physical and chemical properties of water surface discharge are not influenced by pulse repetition rate, very different from those observed for under water discharge. The production yield of H 2 O 2 and degradation rate per pulse of the dye did not significantly vary at different pulse repetition rates under a constant discharge mode on water surface. In addition, the solution temperature, pH, and conductivity for both water surface and underwater discharge reactors were measured to compare their plasma properties for different pulse repetition rates. The results confirm that surface discharge can be employed at high pulse repetition rates as a reliable and advantageous method for industrial and environmental decontamination applications.

  3. column frame for design of reinforced concrete sway frames

    African Journals Online (AJOL)

    adminstrator

    design of slender reinforced concrete columns in sway frames according .... concrete,. Ac = gross cross-sectional area of the columns. Step 3: Effective Buckling Length Factors. The effective buckling length factors of columns in a sway frame shall be computed by .... shall have adequate resistance to failure in a sway mode ...

  4. Dynamics and Control of Distillation Columns - A Critical Survey

    Directory of Open Access Journals (Sweden)

    Sigurd Skogestad

    1997-07-01

    Full Text Available Distillation column dynamics and control have been viewed by many as a very mature or even dead field. However, as is discussed in this paper significant new results have appeared over the last 5-10 years. These results include multiple steady states and instability in simple columns with ideal thermodynamics (which was believed to be impossible, the understanding of the difference between various control configurations and the systematic transformation between these, the feasibility of using the distillate-bottom structure, for control (which was believed to be impossible, the importance of flow dynamics for control studies, the fundamental problems in identifying models from open-loops responses, the use of simple regression estimators to estimate composition from temperatures, and an improved general understanding of the dynamic behavior of distillation columns which includes a better understanding of the fundamental difference between internal and external flow, simple formulas for estimating the dominant time constant, and a derivation of the linearizing effect of logarithmic transformations. These issues apply to all columns, even for ideal mixtures and simple columns with only two products. In addition, there have been significant advances for cases with complex thermodynamics and complex column configurations. These include the behavior and control of azeotropic distillation columns, and the possible complex dynamics of nonideal mixtures and of interlinked columns. However, both for the simple and more complex cases there are still a number of areas where further research is needed.

  5. Computational Studies of Positive and Negative Streamers in Bubbles Suspended in Distilled Water

    KAUST Repository

    Sharma, Ashish

    2017-01-05

    We perform computational studies of nanosecond streamers generated in helium bubbles immersed in distilled water under high pressure conditions. The model takes into account the presence of water vapor in the gas bubble for an accurate description of the chemical kinetics of the discharge. We apply positive and negative trigger voltages much higher than the breakdown voltage and study the dynamic characteristics of the resulting discharge. We observe that, for high positive trigger voltages, the streamer moves along the surface of the gas bubble during the initial stages of the discharge. We also find a considerable difference in the evolution of the streamer discharge for positive and negative trigger voltages with more uniform volumetric distribution of species in the streamer channel for negative trigger voltages due to formation of multiple streamers. We also observe that the presence of water vapor does not influence the breakdown voltage of the discharge but greatly affects the composition of dominant species in the trail of the streamer channel.

  6. Slender CRC Columns

    DEFF Research Database (Denmark)

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    CRC is a high-performance steel fibre reinforced concrete with a typical compressive strength of 150 MPa. Design methods for a number of structural elements have been developed since CRC was invented in 1986, but the current project set out to further investigate the range of columns for which...

  7. Interaction of plasma with magnetic fields in coaxial discharge

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, H.M.; Masoud, M.M. (National Research Centre, Cairo (Egypt))

    1991-01-01

    Previous experiments have shown that, in normal mode of focus operation (67 KJ-20 KV) i.e. without external magnetic fields, the focus exhibits instability growths as revealed by the time integrated X-ray pinhole photographs. A magnetic field which is trapped ahead of the current sheath will reduce the high ejection rate of plasma which occurs during the (r,z) collapse stage. This reduction should lead to a more uniform plasma of larger dimension. If an externally excited axial magnetic field of (10[sup 2]-10[sup 3] G) is introduced at the end of the central electrode of coaxial discharge with 45 [mu]f capacitor bank, U[sub ch]=13-17 KV, peak current [approx]0.5 MA, the decay rate of the current sheath is slowed down and the minimum radius of the column remains large enough. Experiment investigation of the X-ray emission in axial direction from a (12 KJ/20 KV, 480 KA), Mather type focus, showed that the X-ray intensity changes drastically, by superimposing an axial magnetic field of 55 G on the focus. By introducing an external axial magnetic field of intensity 2.4 KG along the coaxial electrodes, this magnetic field has a radial component at distances approach to muzzle of coaxial discharge with charging voltage 10 KV and peak discharge current 100 KA. Presence of these magnetic fields, will cause an increase in intensity of soft X-ray emission. The main purpose of this work is to study the interactions of axial and transverse magnetic fields with plasma sheath during the axial interelectrode propagation, and its effects on the X-ray emission from plasma focus. (author) 4 refs., 7 figs.

  8. Traveling wave model for laser-guided discharges

    International Nuclear Information System (INIS)

    Lampe, Martin; Fernsler, Richard F.; Slinker, Steven P.; Gordon, Daniel F.

    2010-01-01

    We present an easily solvable 1D traveling wave model for laser-guided discharges. By assuming constant propagation speed u, the hydro/electrodynamic/chemistry equations are reduced to ordinary differential equations in retarded time τ. Negative discharges are shown to propagate only if u>μE b , where μ is electron mobility and E b is the breakdown field; positive discharges propagate only if the channel preconductance exceeds ∼6x10 -11 m/Ω. The axial electric field E is shown to spike up to several times E b and then relax to ∼E b for as long as the gas remains cold. In this streamer region, the channel conductance, current, and potential all increase linearly with τ. The transition to the leader stage, where E is much smaller, occurs in two steps: excitation of vibrational and low-lying electronic states, then gas heating. The propagation range decreases as a function of initial radius and (for given maximum voltage) of the voltage rise rate. Expansion of the hot channel is shown to increase the range.

  9. Performance of zeolite scavenge column in Xe monitoring system

    International Nuclear Information System (INIS)

    Wang Qian; Wang Hongxia; Li Wei; Bian Zhishang

    2010-01-01

    In order to improve the performance of zeolite scavenge column, its ability of removal of humidity and carbon dioxide was studied by both static and dynamic approaches. The experimental results show that various factors, including the column length and diameter, the mass of zeolite, the content of water in air, the temperature rise during adsorption, and the activation effectiveness all effect the performance of zeolite column in scavenging humanity and carbon dioxide. Based on these results and previous experience, an optimized design of the zeolite column is made for use in xenon monitoring system. (authors)

  10. Behaviour of normal reinforced concrete columns exposed to different soils

    Directory of Open Access Journals (Sweden)

    Rasheed Laith

    2018-01-01

    Full Text Available Concrete resistance to sulfate attack is one of the most important characteristics for maintaining the durability of concrete. In this study, the effect of the attack of sulfate salts on normal reinforced concrete column was investigated by burying these columns in two types of soils (sandy and clayey in two pits at a depth of 3 m in one of the agricultural areas in the holy city of Karbala, one containing sandy soil (SO3 = 10.609% and the other containing clayey soil with (SO3 = 2.61%. The tests were used (pure axial compression test of reinforced concrete columns, compressive strength test, and splitting tensile strength test, absorption, voids ratio and finally density. It`s found that the strength of RC columns decreasing by (12.51% for age (240 days, for columns buried in clayey soil, where the strength increased by (11.71% for the same period, for columns buried in sandy soils, with respect to the reference column.

  11. Column studies on BTEX biodegradation under microaerophilic and denitrifying conditions

    International Nuclear Information System (INIS)

    Hutchins, S.R.; Moolenaar, S.W.; Rhodes, D.E.

    1992-01-01

    Two column tests were conducted using aquifer material to simulate the nitrate field demonstration project carried out earlier at Traverse City, Michigan. The objectives were to better define the effect nitrate addition had on biodegradation of benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes (BTEX) in the field study, and to determine whether BTEX removal can be enhanced by supplying a limited amount of oxygen as a supplemental electron acceptor. Columns were operated using limited oxygen, limited oxygen plus nitrate, and nitrate alone. In the first column study, benzene was generally recalcitrant compared to the alkylbenzenes (TEX), although some removal did occur. In the second column study, nitrate was deleted from the feed to the column originally receiving nitrate alone and added to the feed of the column originally receiving limited oxygen alone. Although the requirement for nitrate for optimum TEX removal was clearly demonstrated in these columns, there were significant contributions by biotic and abiotic processes other than denitrification which could not be quantified

  12. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...

  13. Strength degradation of oxidized graphite support column in VHTR

    International Nuclear Information System (INIS)

    Park, Byung Ha; No, Hee Cheon

    2010-01-01

    Air-ingress events caused by large pipe breaks are important accidents considered in the design of Very High Temperature Gas-Cooled Reactors (VHTRs). A main safety concern for this type of event is the possibility of core collapse following the failure of the graphite support column, which can be oxidized by ingressed air. In this study, the main target is to predict the strength of the oxidized graphite support column. Through compression tests for fresh and oxidized graphite columns, the compressive strength of IG-110 was obtained. The buckling strength of the IG-110 column is expressed using the following empirical straight-line formula: σ cr,buckling =91.34-1.01(L/r). Graphite oxidation in Zone 1 is volume reaction and that in Zone 3 is surface reaction. We notice that the ultimate strength of the graphite column oxidized in Zones 1 and 3 only depends on the slenderness ratio and bulk density. Its strength degradation oxidized in Zone 1 is expressed in the following nondimensional form: σ/σ 0 =exp(-kd), k=0.114. We found that the strength degradation of a graphite column, oxidized in Zone 3, follows the above buckling empirical formula as the slenderness of the column changes. (author)

  14. Investigation of Gas Holdup in a Vibrating Bubble Column

    Science.gov (United States)

    Mohagheghian, Shahrouz; Elbing, Brian

    2015-11-01

    Synthetic fuels are part of the solution to the world's energy crisis and climate change. Liquefaction of coal during the Fischer-Tropsch process in a bubble column reactor (BCR) is a key step in production of synthetic fuel. It is known from the 1960's that vibration improves mass transfer in bubble column. The current study experimentally investigates the effect that vibration frequency and amplitude has on gas holdup and bubble size distribution within a bubble column. Air (disperse phase) was injected into water (continuous phase) through a needle shape injector near the bottom of the column, which was open to atmospheric pressure. The air volumetric flow rate was measured with a variable area flow meter. Vibrations were generated with a custom-made shaker table, which oscillated the entire column with independently specified amplitude and frequency (0-30 Hz). Geometric dependencies can be investigated with four cast acrylic columns with aspect ratios ranging from 4.36 to 24, and injector needle internal diameters between 0.32 and 1.59 mm. The gas holdup within the column was measured with a flow visualization system, and a PIV system was used to measure phase velocities. Preliminary results for the non-vibrating and vibrating cases will be presented.

  15. Plasma polymerization at different positions in an asymmetric ethylene discharge

    International Nuclear Information System (INIS)

    Trieschmann, Jan; Hegemann, Dirk

    2011-01-01

    The characteristics of plasma polymerization are investigated in an asymmetric, capacitively coupled plasma discharge. Here, the deposition in different plasma zones, i.e. on the driven electrode, within the plasma bulk and the plasma sheath as well as approximately at the plasma-sheath edge, is investigated. Principal expectations are perfectly met, though new interesting dependences of the obtained a-C : H coatings with respect to film properties and deposition rates are also found. That is, the deposition rates as measured on thin, small glass slides placed directly on the electrode are considerably higher than everywhere else in the plasma, yet only single-sided. In contrast, the deposition rates on the samples within the plasma are lowered depending on the exact placement, while a double-sided coating is obtained. Furthermore, film properties, such as the film density, are highly dependent on the sample placement in the plasma, which can even be higher under floating conditions. With simple physical arguments we are able to show the relations between the deposition rate and the energy input into the plasma as well as between the energy density during film growth and the film density itself.

  16. Multi-column adsorption systems with condenser for tritiated water vapor removal

    International Nuclear Information System (INIS)

    Kotoh, Kenji; Kudo, Kazuhiko

    1996-01-01

    Two types of multi-column adsorption system are proposed as the system for removal of tritiated moisture from tritium process gases or/and handling room atmospheres. The types are of recycle use of adsorption columns, and are composed of twin or triplet columns and one condenser which is used for collecting the adsorbed moisture from columns in desorption process. The systems utilize the dry gas from a working column as the purge gas for regenerating a saturated column and appropriate an active column for recovery of the tritiated moisture passing through the condenser. Each column hence needs the additional amount of adsorbent for collecting the moisture from the condenser. In the modeling and design of an adsorption column, it is primary to estimate the necessary amount of a candidate adsorbent for its packed-bed. The performance of the proposed systems is examined here by analyzing the dependence of the necessary amount of adsorbent for their columns on process operational conditions and adsorbent moisture-adsorption characteristics. The result shows that the necessary amount is sensitive to the types of adsorption isotherm, and suggests that these systems should employ adsorbents which exhibit the Langmuir-type isotherms. (author)

  17. Seismic Performance of High-Ductile Fiber-Reinforced Concrete Short Columns

    Directory of Open Access Journals (Sweden)

    Mingke Deng

    2018-01-01

    Full Text Available This study mainly aims to investigate the effectiveness of high-ductile fiber-reinforced concrete (HDC as a means to enhance the seismic performance of short columns. Six HDC short columns and one reinforced concrete (RC short column were designed and tested under lateral cyclic loading. The influence of the material type (concrete or HDC, axial load, stirrup ratio, and shear span ratio on crack patterns, hysteresis behavior, shear strength, deformation capacity, energy dissipation, and stiffness degradation was presented and discussed, respectively. The test results show that the RC short column failed in brittle shear with poor energy dissipation, while using HDC to replace concrete can effectively improve the seismic behavior of the short columns. Compared with the RC short column, the shear strength of HDC specimens was improved by 12.6–30.2%, and the drift ratio and the energy dissipation increases were 56.9–88.5% and 237.7–336.7%, respectively, at the ultimate displacement. Additionally, the prediction model of the shear strength for RC columns based on GB50010-2010 (Chinese code can be safely adopted to evaluate the shear strength of HDC short columns.

  18. Discharge current characteristics as an 'electrical method' for glow discharge plasma diagnosis

    International Nuclear Information System (INIS)

    Toma, M.; Paraschivescu, Alina; Morminches, Anisoara

    2001-01-01

    In its simplest form, the glow discharge can be established by passing an electric current through gas between two electrodes. The gas and the electrodes are contained in an insulating envelope. In many technological applications, and not only, the plasma devices are often treated like a black box. There is a series of external parameters or control variables which can be adjusted to obtain a desired effect, namely, the operating voltage, gas pressure, gas nature, gas flow rate, magnetic field strength and magnetic field configuration, electric field geometry, interelectrode distance, and cathode characteristics. The discharge current can be controlled by each of the above control variables. The core idea of this work is the following: a lot of information about the phenomena from the discharge volume, at electrodes or at the discharge bounding wall surface, can be obtained knowing how the change of one of the control parameters influences the discharge current. The following regimes were analyzed: dark discharges (background ionization, saturation regime, Townsend regime, corona regime), glow discharge (the normal and abnormal discharge) and arc discharge (glow to arc transition, non-thermal arcs, thermal arcs). It was concluded that the nonlinearity in the shape of the discharge current characteristics as a function of an external control parameter, can be correlated with the elementary processes and the dynamics of different space charge structures generated in plasma devices. (authors)

  19. Design of a Cryogenic Distillation Column for JET Water Detritiation System for Tritium Recovery

    International Nuclear Information System (INIS)

    Parracho, A.I.; Camp, P.; Dalgliesh, P.; Hollingsworth, A.; Lefebvre, X.; Lesnoj, S.; Sacks, R.; Shaw, R.; Smith, R.; Wakeling, B.

    2015-01-01

    A Water Detritiation System (WDS) is currently being designed and manufactured to be installed in the Active Gas Handling System (AGHS) of JET, currently the largest magnetic fusion experiment in the world. JET has been designed and built to study fusion operating conditions with the plasma fuelling done by means of a deuterium-tritium gas mixture. AGHS is a plant designed and built to safely process gas mixtures and impurities containing tritium recovered from the JET torus exhaust gases. Tritium is removed from these gas mixtures and recycled. Tritium depleted gases are sent to Exhaust Detritiation System (EDS) for final tritium removal prior to discharge into the environment. In EDS, tritium and tritiated species are catalytically oxidized into water, this tritiated water is then adsorbed onto molecular sieve beds (MSB). After saturation the MSBs are heated and the water is desorbed and collected for tritium recovery. The WDS facility is designed to recover tritium from water with an average activity of 1.9 GBq/l, and is able to process water with activities of 85 GBq/l and higher. Tritiated water is filtered and supplied to the electrolyser where the water is converted into gaseous oxygen and tritiated hydrogen. The hydrogen stream is first purified by selective diffusion through membranes of palladium alloy and then is fed to two cryogenic distillation columns (CD). These operate in parallel or in series depending on the water activity. In the CD columns, hydrogen isotopes containing tritium are recovered as the bottom product and hydrogen, the top product, is safely discarded to a stack. The CD columns are foreseen to have a throughput between 200 and 300 mole/h of hydrogen isotopes vapour and they operate at approximately ≈21.2K and 105 kPa. The design of the CD columns will be presented in this work. This work has been carried out within the framework of the Contract for the Operation of the JET Facilities and has received funding from the European Union

  20. Heart attack - discharge

    Science.gov (United States)

    ... and lifestyle Cholesterol - drug treatment Controlling your high blood pressure Deep vein thrombosis - discharge Dietary fats explained Fast food tips Heart attack - discharge Heart attack - what to ask your doctor Heart bypass ... pacemaker - discharge High blood pressure - what to ask your doctor How to read ...