WorldWideScience

Sample records for positive cad mark

  1. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  2. Design and Positioning of Diacritical Marks in Latin Typefaces

    Directory of Open Access Journals (Sweden)

    Ivan Rajković

    2010-04-01

    Full Text Available This paper presents relevant information concerning the types, shape and positioning of diacritical marks in Latin typefaces. The aim is to increase the awareness of the importance of diacritics, their design and use. The design of the low-ercase dcroat letter presents a particular problem, because it is present only in the Croatian and Vietnamese script and is therefore often incorrectly designed or it is missing the respective font. Data on the most common methods of shaping and positioning of this diacritical sign was collected by measuring the geometry of the dcroat letter in various fonts. Most common designers’ mistakes were shown and evaluated. Suggestions for the design of diacritical marks are proposed taking into account asymmetry, width, uppercase, vertical and horizontal positioning and cultural preferences.

  3. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  4. A CAD-CAM prosthodontic option and gingival zenith position for a rotated maxillary right central incisor: An evaluation

    Directory of Open Access Journals (Sweden)

    Mukesh Singhal

    2012-01-01

    Conclusion: Digital imaging provides an immediate treatment option for the patients. Software also provides an interim aid, for the clinician as well as technician, in the form of two-dimensional photographs. CAD-CAM is entirely a helping instrument against the conservative prosthetic options and gingival zenith position for a rotated central incisor. It helps in patient education and in motivation.

  5. Computer aided design (CAD) for electronics improvement of the nuclear channels of TRIGA Mark III reactor of the ININ

    International Nuclear Information System (INIS)

    Gonzalez M, J.L.; Rivero G, T.; Aguilar H, F.

    2007-01-01

    The 4 neutron measurement channels of the digital control console (CCD) of the TRIGA Mark III reactor (RTMIII) of the ININ, its were designed and built with the corresponding Quality Guarantee program, being achieved the one licensing to replace the old console. With the time they were carried out some changes to improve and to not solve some problems detected in the tests, verification and validation, requiring to modify the circuits originally designed. In this work the corrective actions carried out to eliminate the Non Conformity generated by these problems, being mentioned the advantages of using modern tools, as the software applied to the Attended Engineering by Computer, and those obtained results are presented. (Author)

  6. Feature-guided analysis for reduction of false positives in CAD of polyps for computed tomographic colonography

    International Nuclear Information System (INIS)

    Naeppi, Janne; Yoshida, Hiroyuki

    2003-01-01

    We evaluated the effect of our novel technique of feature-guided analysis of polyps on the reduction of false-positive (FP) findings generated by our computer-aided diagnosis (CAD) scheme for the detection of polyps from computed tomography colonographic data sets. The detection performance obtained by use of feature-guided analysis in the segmentation and feature analysis of polyp candidates was compared with that obtained by use of our previously employed fuzzy clustering technique. We also evaluated the effect of a feature called modified gradient concentration (MGC) on the detection performance. A total of 144 data sets, representing prone and supine views of 72 patients that included 14 patients with 21 colorectal polyps 5-25 mm in diameter, were used in the evaluation. At a 100% by-patient (95% by-polyp) detection sensitivity, the FP rate of our CAD scheme with feature-guided analysis based on round-robin evaluation was 1.3 (1.5) FP detections per patient. This corresponds to a 70-75 % reduction in the number of FPs obtained by use of fuzzy clustering at the same sensitivity levels. Application of the MGC feature instead of our previously used gradient concentration feature did not improve the detection result. The results indicate that feature-guided analysis is useful for achieving high sensitivity and a low FP rate in our CAD scheme

  7. Evaluation of concordance between CAD/CAM and clinical positions of abutment shoulder against mucosal margin: an observational study.

    Science.gov (United States)

    Pietruski, Jan K; Skurska, Anna; Bernaczyk, Anna; Milewski, Robert; Pietruska, Maria Julia; Gehrke, Peter; Pietruska, Małgorzata D

    2018-05-02

    While working on CAD/CAM-customized abutments, the use of standard impression copings with a circular diameter produces inconsistency within the emergence profile. It may begin with a collapse of the supra-implant mucosa during impression taking, then lead to a computer-generated mismatch of the position and outline of the abutment shoulder, and consequently result in a compromised outcome of anticipated treatment. The aim of the study was to compare the virtual and clinical positions of the abutment shoulder in relation to the mucosal margin after the abutment delivery. Conventional open-tray impression takings followed uncovering surgery. Master casts were scanned with a desktop scanner. Clinical examinations took place after abutment's insertion and temporization (T1) and prior to cementation of the definitive crown (T2). The distances between the abutment shoulder and marginal soft tissue were measured intraorally in four aspects and juxtaposed with those on the virtual model. The study evaluated 257 dental implants and CAD/CAM-customized abutments. As T1 and T2 showed, there was a positive correlation between the virtually designed abutment shoulder position and matching clinical location relative to the mucosal margin. In 42.1% of cases, the distance between the mucosal margin and the abutment shoulder did not change. It increased in 36.3% of cases while a decrease occurred in 21.6% of them. Computer-set position of the abutment shoulder in relation to the mucosal margin can be predictably implemented in clinical practice.

  8. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  9. Improvement of CD-SEM mark position measurement accuracy

    Science.gov (United States)

    Kasa, Kentaro; Fukuhara, Kazuya

    2014-04-01

    CD-SEM is now attracting attention as a tool that can accurately measure positional error of device patterns. However, the measurement accuracy can get worse due to pattern asymmetry as in the case of image based overlay (IBO) and diffraction based overlay (DBO). For IBO and DBO, a way of correcting the inaccuracy arising from measurement patterns was suggested. For CD-SEM, although a way of correcting CD bias was proposed, it has not been argued how to correct the inaccuracy arising from pattern asymmetry using CD-SEM. In this study we will propose how to quantify and correct the measurement inaccuracy affected by pattern asymmetry.

  10. Reproducibility of Computer-Aided Detection Marks in Digital Mammography

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Kim, Sun Mi; Im, Jung Gi; Cha, Joo Hee

    2007-01-01

    To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. A CAD system was applied preoperatively to the fulfilled digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33 83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications

  11. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    Science.gov (United States)

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  12. The effect of altered road markings on speed and lateral position : a meta-analysis.

    NARCIS (Netherlands)

    Davidse, R.J. Driel, C.J.G. van & Goldenbeld, C.

    2004-01-01

    This report describes the results of a meta-analysis of a number of small-scale studies into the effects of changed road markings on the speed and lateral position of motor vehicles. It was examined whether predictions can be made about the general effects of altered road markings. Several kinds of

  13. ULTOR(Registered TradeMark) Passive Pose and Position Engine For Spacecraft Relative Navigation

    Science.gov (United States)

    Hannah, S. Joel

    2008-01-01

    The ULTOR(Registered TradeMark) Passive Pose and Position Engine (P3E) technology, developed by Advanced Optical Systems, Inc (AOS), uses real-time image correlation to provide relative position and pose data for spacecraft guidance, navigation, and control. Potential data sources include a wide variety of sensors, including visible and infrared cameras. ULTOR(Registered TradeMark) P3E has been demonstrated on a number of host processing platforms. NASA is integrating ULTOR(Registerd TradeMark) P3E into its Relative Navigation System (RNS), which is being developed for the upcoming Hubble Space Telescope (HST) Servicing Mission 4 (SM4). During SM4 ULTOR(Registered TradeMark) P3E will perform realtime pose and position measurements during both the approach and departure phases of the mission. This paper describes the RNS implementation of ULTOR(Registered TradeMark) P3E, and presents results from NASA's hardware-in-the-loop simulation testing against the HST mockup.

  14. Bomb CAD

    International Nuclear Information System (INIS)

    Massa, R.J.; Howard, J.W.

    1989-01-01

    This paper describes BombCAD a computer-aided analysis technique for assessing the damage to diverse structures which results from specific high explosive detonations within or near the structure. BombCAD analyzes the vulnerability of specific facilities to bomb attach, and evaluates siting, screening and hardening/softening aspects of comprehensive bomb defense programs. The paper describes BombCAD's architectural models of specific structures, computations of blastwave effects and the paradigms which relate blast wave effects to both structural damage and human injury. The use of BombCAD in bomb attack vulnerability assessment, facility design, bomb threat response planning and post-incident analyses is described and field examples are presented

  15. An NF-Y-dependent switch of positive and negative histone methyl marks on CCAAT promoters.

    Directory of Open Access Journals (Sweden)

    Giacomo Donati

    Full Text Available BACKGROUND: Histone tails have a plethora of different post-translational modifications, which are located differently in "open" and "closed" parts of genomes. H3K4me3/H3K79me2 and H4K20me3 are among the histone marks associated with the early establishment of active and inactive chromatin, respectively. One of the most widespread promoter elements is the CCAAT box, bound by the NF-Y trimer. Two of NF-Y subunits have an H2A-H2B-like structure. PRINCIPAL FINDINGS: We established the causal relationship between NF-Y binding and positioning of methyl marks, by ChIP analysis of mouse and human cells infected with a dominant negative NF-YA: a parallel decrease in NF-Y binding, H3K4me3, H3K79me2 and transcription was observed in promoters that are dependent upon NF-Y. On the contrary, changes in the levels of H3K9-14ac were more subtle. Components of the H3K4 methylating MLL complex are not recruited in the absence of NF-Y. As for repressed promoters, NF-Y removal leads to a decrease in the H4K20me3 mark and deposition of H3K4me3. CONCLUSIONS: Two relevant findings are reported: (i NF-Y gains access to its genomic locations independently from the presence of methyl histone marks, either positive or negative; (ii NF-Y binding has profound positive or negative consequences on the deposition of histone methyl marks. Therefore NF-Y is a fundamental switch at the heart of decision between gene activation and repression in CCAAT regulated genes.

  16. A wheat cinnamyl alcohol dehydrogenase TaCAD12 contributes to host resistance to the sharp eyespot disease

    Directory of Open Access Journals (Sweden)

    Wei Rong

    2016-11-01

    Full Text Available Sharp eyespot, caused mainly by the necrotrophic fungus Rhizoctonia cerealis, is a destructive disease in hexaploid wheat (Triticum aestivum L.. In Arabidopsis, certain cinnamyl alcohol dehydrogenases (CADs have been implicated in monolignol biosynthesis and in defense response to bacterial pathogen infection. However, little is known about CADs in wheat defense responses to necrotrophic or soil-borne pathogens. In this study, we isolate a wheat CAD gene TaCAD12 in response to R. cerealis infection through microarray-based comparative transcriptomics, and study the enzyme activity and defense role of TaCAD12 in wheat. The transcriptional levels of TaCAD12 in sharp eyespot-resistant wheat lines were significantly higher compared with those in susceptible wheat lines. The sequence and phylogenetic analyses revealed that TaCAD12 belongs to IV group in CAD family. The biochemical assay proved that TaCAD12 protein is an authentic CAD enzyme and possesses catalytic efficiencies towards both coniferyl aldehyde and sinapyl aldehyde. Knock-down of TaCAD12 transcript significantly repressed resistance of the gene-silenced wheat plants to sharp eyespot caused by R. cerealis, whereas TaCAD12 overexpression markedly enhanced resistance of the transgenic wheat lines to sharp eyespot. Furthermore, certain defense genes (Defensin, PR10, PR17c, and Chitinase1 and monolignol biosynthesis-related genes (TaCAD1, TaCCR, and TaCOMT1 were up-regulated in the TaCAD12-overexpressing wheat plants but down-regulated in TaCAD12-silencing plants. These results suggest that TaCAD12 positively contributes to resistance against sharp eyespot through regulation of the expression of certain defense genes and monolignol biosynthesis-related genes in wheat.

  17. WOCN Society and AUA Position Statement on Preoperative Stoma Site Marking for Patients Undergoing Urostomy Surgery.

    Science.gov (United States)

    Salvadalena, Ginger; Hendren, Samantha; McKenna, Linda; Muldoon, Roberta; Netsch, Debra; Paquette, Ian; Pittman, Joyce; Ramundo, Janet; Steinberg, Gary

    2015-01-01

    Marking the optimal location for a stoma preoperatively enhances the likelihood of a patient's independence in stoma care, predictable pouching system wear times, and resumption of normal activities. Urologists and certified ostomy nurses are the optimal clinicians to select and mark stoma sites, as this skill is a part of their education, practice, and training. However, these providers are not always available, particularly in emergency situations. The purpose of this position statement, developed by the Wound, Ostomy and Continence Nurses Society in collaboration with the American Urological Association and the American Society of Colon and Rectal Surgeons, is to provide a guideline to assist clinicians (especially those who are not surgeons or WOC nurses) in selecting an effective stoma site.

  18. Sockets Manufactured by CAD/CAM Method Have Positive Effects on the Quality of Life of Patients With Transtibial Amputation.

    Science.gov (United States)

    Karakoç, Mehmet; Batmaz, İbrahim; Sariyildiz, Mustafa Akif; Yazmalar, Levent; Aydin, Abdülkadir; Em, Serda

    2017-08-01

    Patients with amputation need prosthesis to comfortably move around. One of the most important parts of a good prosthesis is the socket. Currently, the most commonly used method is the traditional socket manufacturing method, which involves manual work; however, computer-aided design/computer-aided manufacturing (CAD/CAM) is also being used in the recent years. The present study aimed to investigate the effects of sockets manufactured by traditional and CAD/CAM method on clinical characteristics and quality of life of patients with transtibial amputation. The study included 72 patients with transtibial amputation using prosthesis, 36 of whom had CAD/CAM prosthetic sockets (group 1) and 36 had traditional prosthetic sockets (group 2). Amputation reason, prosthesis lifetime, walking time and distance with prosthesis, pain-free walking time with prosthesis, production time of the prosthesis, and adaptation time to the prosthesis were questioned. Quality of life was assessed using the 36-item Short Form Health Survey questionnaire and the Trinity Amputation and Prosthesis Experience Scales. Walking time and distance and pain-free walking time with prosthesis were significantly better in group 1 than those in group 2. Furthermore, the prosthesis was applied in a significantly shorter time, and socket adaptation time was significantly shorter in group 1. Except emotional role limitation, all 36-item Short Form Healthy Survey questionnaire parameters were significantly better in group 1 than in group 2. Trinity Amputation and Prosthesis Experience Scales activity limitation scores of group 1 were lower, and Trinity Amputation and Prosthesis Experience Scales satisfaction with the prosthesis scores were higher than those in group 2. Our study demonstrated that the sockets manufactured by CAD/CAM methods yield better outcomes in quality of life of patients with transtibial amputation than the sockets manufactured by the traditional method.

  19. Comprehensive Auto CAD

    International Nuclear Information System (INIS)

    Jang, Taekju

    1993-06-01

    This book starts introduction of conception, application system, software for CAD, function of Auto CAD, kinds and function of Auto CAD files. It deals with starting of Auto CAD, dialogue box and Auto CAD interface, utility command, 2D drawing command, check command, control system, dimension, hatching command, layer command, block, 3D drawing, plotting and printing, auto CAD and application of data, supply program of auto CAD, AME and region modeler, EDLIN, script optimization of Auto CAD and composition on demand.

  20. The interplay of attention economics and computer-aided detection marks in screening mammography

    Science.gov (United States)

    Schwartz, Tayler M.; Sridharan, Radhika; Wei, Wei; Lukyanchenko, Olga; Geiser, William; Whitman, Gary J.; Haygood, Tamara Miner

    2016-03-01

    Introduction: According to attention economists, overabundant information leads to decreased attention for individual pieces of information. Computer-aided detection (CAD) alerts radiologists to findings potentially associated with breast cancer but is notorious for creating an abundance of false-positive marks. We suspected that increased CAD marks do not lengthen mammogram interpretation time, as radiologists will selectively disregard these marks when present in larger numbers. We explore the relevance of attention economics in mammography by examining how the number of CAD marks affects interpretation time. Methods: We performed a retrospective review of bilateral digital screening mammograms obtained between January 1, 2011 and February 28, 2014, using only weekend interpretations to decrease distractions and the likelihood of trainee participation. We stratified data according to reader and used ANOVA to assess the relationship between number of CAD marks and interpretation time. Results: Ten radiologists, with median experience after residency of 12.5 years (range 6 to 24,) interpreted 1849 mammograms. When accounting for number of images, Breast Imaging Reporting and Data System category, and breast density, increasing numbers of CAD marks was correlated with longer interpretation time only for the three radiologists with the fewest years of experience (median 7 years.) Conclusion: For the 7 most experienced readers, increasing CAD marks did not lengthen interpretation time. We surmise that as CAD marks increase, the attention given to individual marks decreases. Experienced radiologists may rapidly dismiss larger numbers of CAD marks as false-positive, having learned that devoting extra attention to such marks does not improve clinical detection.

  1. Immersive CAD

    Energy Technology Data Exchange (ETDEWEB)

    Ames, A.L.

    1999-02-01

    This paper documents development of a capability for performing shape-changing editing operations on solid model representations in an immersive environment. The capability includes part- and assembly-level operations, with part modeling supporting topology-invariant and topology-changing modifications. A discussion of various design considerations in developing an immersive capability is included, along with discussion of a prototype implementation we have developed and explored. The project investigated approaches to providing both topology-invariant and topology-changing editing. A prototype environment was developed to test the approaches and determine the usefulness of immersive editing. The prototype showed exciting potential in redefining the CAD interface. It is fun to use. Editing is much faster and friendlier than traditional feature-based CAD software. The prototype algorithms did not reliably provide a sufficient frame rate for complex geometries, but has provided the necessary roadmap for development of a production capability.

  2. Utterance-final position and pitch marking aid word learning in school-age children.

    Science.gov (United States)

    Filippi, Piera; Laaha, Sabine; Fitch, W Tecumseh

    2017-08-01

    We investigated the effects of word order and prosody on word learning in school-age children. Third graders viewed photographs belonging to one of three semantic categories while hearing four-word nonsense utterances containing a target word. In the control condition, all words had the same pitch and, across trials, the position of the target word was varied systematically within each utterance. The only cue to word-meaning mapping was the co-occurrence of target words and referents. This cue was present in all conditions. In the Utterance-final condition, the target word always occurred in utterance-final position, and at the same fundamental frequency as all the other words of the utterance. In the Pitch peak condition, the position of the target word was varied systematically within each utterance across trials, and produced with pitch contrasts typical of infant-directed speech (IDS). In the Pitch peak + Utterance-final condition, the target word always occurred in utterance-final position, and was marked with a pitch contrast typical of IDS. Word learning occurred in all conditions except the control condition. Moreover, learning performance was significantly higher than that observed with simple co-occurrence ( control condition) only for the Pitch peak + Utterance-final condition. We conclude that, for school-age children, the combination of words' utterance-final alignment and pitch enhancement boosts word learning.

  3. Clusterless Decoding of Position From Multiunit Activity Using A Marked Point Process Filter

    Science.gov (United States)

    Deng, Xinyi; Liu, Daniel F.; Kay, Kenneth; Frank, Loren M.; Eden, Uri T.

    2016-01-01

    Point process filters have been applied successfully to decode neural signals and track neural dynamics. Traditionally, these methods assume that multiunit spiking activity has already been correctly spike-sorted. As a result, these methods are not appropriate for situations where sorting cannot be performed with high precision such as real-time decoding for brain-computer interfaces. As the unsupervised spike-sorting problem remains unsolved, we took an alternative approach that takes advantage of recent insights about clusterless decoding. Here we present a new point process decoding algorithm that does not require multiunit signals to be sorted into individual units. We use the theory of marked point processes to construct a function that characterizes the relationship between a covariate of interest (in this case, the location of a rat on a track) and features of the spike waveforms. In our example, we use tetrode recordings, and the marks represent a four-dimensional vector of the maximum amplitudes of the spike waveform on each of the four electrodes. In general, the marks may represent any features of the spike waveform. We then use Bayes’ rule to estimate spatial location from hippocampal neural activity. We validate our approach with a simulation study and with experimental data recorded in the hippocampus of a rat moving through a linear environment. Our decoding algorithm accurately reconstructs the rat’s position from unsorted multiunit spiking activity. We then compare the quality of our decoding algorithm to that of a traditional spike-sorting and decoding algorithm. Our analyses show that the proposed decoding algorithm performs equivalently or better than algorithms based on sorted single-unit activity. These results provide a path toward accurate real-time decoding of spiking patterns that could be used to carry out content-specific manipulations of population activity in hippocampus or elsewhere in the brain. PMID:25973549

  4. An analytical approach to the positive reactivity void coefficient of TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Edgue, Erdinc; Yarman, Tolga

    1988-01-01

    Previous calculations of reactivity void coefficient of I.T.U. TRIGA Mark-II Reactor was done by the second author et al. The theoretical predictions were afterwards, checked in this reactor experimentally. In this work an analytical approach is developed to evaluate rather quickly the reactivity void coefficient of I.T.U. TRIGA Mark-II, versus the size of the void inserted into the reactor. It is thus assumed that the reactor is a cylindrical, bare nuclear system. Next a belt of water of 2πrΔrH is introduced axially at a distance r from the center line of the system. r here, is the thickness of the belt, and H is the height of the reactor. The void is described by decreasing the water density in the belt region. A two group diffusion theory is adopted to determine the criticality of our configuration. The space dependency of the group fluxes are, thereby, assumed to be J 0 (2.405 r / R) cos (π Z / H), the same as that associated with the original bare reactor uniformly loaded prior to the change. A perturbation type of approach, thence, furnishes the effect of introducing a void in the belt region. The reactivity void coefficient can, rather surprisingly, be indeed positive. To our knowledge, this fact had not been established, by the supplier. The agreement of our predictions with the experimental results is good. (author)

  5. Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.

    Science.gov (United States)

    Buhmann, Sonja; Herzog, Peter; Liang, Jin; Wolf, Mathias; Salganicoff, Marcos; Kirchhoff, Chlodwig; Reiser, Maximilian; Becker, Christoph H

    2007-06-01

    To evaluate the performance of a prototype computer-aided diagnosis (CAD) tool using artificial intelligence techniques for the detection of pulmonary embolism (PE) and the possible benefit for general radiologists. Forty multidetector row computed tomography datasets (16/64- channel scanner) using 100 kVp, 100 mAs effective/slice, and 1-mm axial reformats in a low-frequency reconstruction kernel were evaluated. A total of 80 mL iodinated contrast material was injected at a flow rate of 5 mL/seconds. Primarily, six general radiologists marked any PE using a commercially available lung evaluation software with simultaneous, automatic processing by CAD in the background. An expert panel consisting of two chest radiologists analyzed all PE marks from the readers and CAD, also searching for additional finding primarily missed by both, forming the ground truth. The ground truth consisted of 212 emboli. Of these, 65 (31%) were centrally and 147 (69%) were peripherally located. The readers detected 157/212 emboli (74%) leading to a sensitivity of 97% (63/65) for central and 70% (103/147) for peripheral emboli with 9 false-positive findings. CAD detected 168/212 emboli (79%), reaching a sensitivity of 74% for central (48/65) and 82%(120/147) for peripheral emboli. A total of 154 CAD candidates were considered as false positives, yielding an average of 3.85 false positives/case. The CAD software showed a sensitivity comparable to that of the general radiologists, but with more false positives. CAD detection of findings incremental to the radiologists suggests benefit when used as a second reader. Future versions of CAD have the potential to further increase clinical benefit by improving sensitivity and reducing false marks.

  6. Computer aided design (CAD) for electronics improvement of the nuclear channels of TRIGA Mark III reactor of the ININ; Diseno asistido por computadora (DAC) para mejorar la electronica de los canales nucleares del reactor TRIGA Mark III del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, J.L.; Rivero G, T.; Aguilar H, F. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: jlgm@nuclear.inin.mx

    2007-07-01

    The 4 neutron measurement channels of the digital control console (CCD) of the TRIGA Mark III reactor (RTMIII) of the ININ, its were designed and built with the corresponding Quality Guarantee program, being achieved the one licensing to replace the old console. With the time they were carried out some changes to improve and to not solve some problems detected in the tests, verification and validation, requiring to modify the circuits originally designed. In this work the corrective actions carried out to eliminate the Non Conformity generated by these problems, being mentioned the advantages of using modern tools, as the software applied to the Attended Engineering by Computer, and those obtained results are presented. (Author)

  7. Radiological assessment of the position of the tibial tuberosity by means of a marking wire in knees with patellofemoral arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nagamine, R.; Miura, H.; Urabe, K.; Matsuda, S.; Chen, W.J.; Matsunobu, T.; Iwamoto, Y. [Department of Orthopaedic Surgery, Faculty of Medicine, Kyushu University, Fukuoka (Japan)

    1999-01-01

    Objective. To assess the usefulness of a new axial radiographic technique in knees with patellofemoral arthritis (PF-OA). Design and patients. After a marking wire had been attached to the skin on the tibial tuberosity so that the wire matched the width of the patellar tendon, an axial radiograph was taken at 30 of flexion in 16 normal knees and 14 PF-OA knees in which computed tomographic analysis had revealed a laterally positioned tibial tuberosity at 30 of flexion. The distance of the marking wire from the lateral condyle and from the patellar groove was compared between the two groups. Results. The marking wire was located significantly laterally in PF-OA knees compared with normal knees. Conclusion. An axial radiograph with a marking wire on the tibial tuberosity is useful for assessing the position of the tibial tuberosity in PF-OA knees. (orig.) With 8 figs., 1 tab., 6 refs.

  8. Radiological assessment of the position of the tibial tuberosity by means of a marking wire in knees with patellofemoral arthritis

    International Nuclear Information System (INIS)

    Nagamine, R.; Miura, H.; Urabe, K.; Matsuda, S.; Chen, W.J.; Matsunobu, T.; Iwamoto, Y.

    1999-01-01

    Objective. To assess the usefulness of a new axial radiographic technique in knees with patellofemoral arthritis (PF-OA). Design and patients. After a marking wire had been attached to the skin on the tibial tuberosity so that the wire matched the width of the patellar tendon, an axial radiograph was taken at 30 of flexion in 16 normal knees and 14 PF-OA knees in which computed tomographic analysis had revealed a laterally positioned tibial tuberosity at 30 of flexion. The distance of the marking wire from the lateral condyle and from the patellar groove was compared between the two groups. Results. The marking wire was located significantly laterally in PF-OA knees compared with normal knees. Conclusion. An axial radiograph with a marking wire on the tibial tuberosity is useful for assessing the position of the tibial tuberosity in PF-OA knees. (orig.)

  9. Modeling of the positioning system and visual mark-up of historical cadastral maps

    Directory of Open Access Journals (Sweden)

    Tomislav Jakopec

    2013-03-01

    Full Text Available The aim of the paper is to present of the possibilities of positioning and visual markup of historical cadastral maps onto Google maps using open source software. The corpus is stored in the Croatian State Archives in Zagreb, in the Maps Archive for Croatia and Slavonia. It is part of cadastral documentation that consists of cadastral material from the period of first cadastral survey conducted in the Kingdom of Croatia and Slavonia from 1847 to 1877, and which is used extensively according to the data provided by the customer service of the Croatian State Archives. User needs on the one side and the possibilities of innovative implementation of ICT on the other have motivated the development of the system which would use digital copies of original cadastral maps and connect them with systems like Google maps, and thus both protect the original materials and open up new avenues of research related to the use of originals. With this aim in mind, two cadastral map presentation models have been created. Firstly, there is a detailed display of the original, which enables its viewing using dynamic zooming. Secondly, the interactive display is facilitated through blending the cadastral maps with Google maps, which resulted in establishing links between the coordinates of the digital and original plans through transformation. The transparency of the original can be changed, and the user can intensify the visibility of the underlying layer (Google map or the top layer (cadastral map, which enables direct insight into parcel dynamics over a longer time-span. The system also allows for the mark-up of cadastral maps, which can lead to the development of the cumulative index of all terms found on cadastral maps. The paper is an example of the implementation of ICT for providing new services, strengthening cooperation with the interested public and related institutions, familiarizing the public with the archival material, and offering new possibilities for

  10. AutoCAD

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1998-01-01

    I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium.......I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium....

  11. CAD-guidelines

    International Nuclear Information System (INIS)

    Schlechtendahl, E.G.; Lang-Lendorff, G.

    1982-10-01

    The CAD-guidelines (CAD = Computer Aided Design) contain rules for programming, structuring and documentation of programs. The standard deals with the structure of CAD-programs, their components, the programming-methods, the language etc. It describes what documents and references are necessary for a CAD-program. In order to gain a broad application of CAD criteria like portability and completeness of the documentation for an effective maintenance are as important as a transparent way of producing CAD-software. (orig.) [de

  12. Echidna Mark II: one giant leap for 'tilting spine' fibre positioning technology

    Science.gov (United States)

    Gilbert, James; Dalton, Gavin

    2016-07-01

    The Australian Astronomical Observatory's 'tilting spine' fibre positioning technology has been redeveloped to provide superior performance in a smaller package. The new design offers demonstrated closed-loop positioning errors of control electronics design, reducing the system's overall size, and improving modularity. Every spine is now a truly independent unit with a dedicated drive circuit and no restrictions on the timing or direction of fibre motion.

  13. Learning Auto CAD 2004

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-15

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  14. Learning Auto CAD 2004

    International Nuclear Information System (INIS)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-01

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  15. 'Land-marks of the universe': John Herschel against the background of positional astronomy.

    Science.gov (United States)

    Case, Stephen

    2015-01-01

    John Herschel (1792-1871) was the leading British natural philosopher of the nineteenth century, widely known and regarded for his work in philosophy, optics and chemistry as well as his important research and popular publications on astronomy. To date, however, there exists no extended treatment of his astronomical career. This paper, part of a larger study exploring Herschel's contributions to astronomy, examines his work in the context of positional astronomy, the dominant form of astronomical practice throughout his lifetime. Herschel, who did not himself practice positional astronomy and who was known for his non-meridional observations of specific stellar objects, was nonetheless a strong advocate for positional astronomy-but for very different reasons than the terrestrial applications to which it was most often put. For Herschel, the star catalogues of positional astronomy were the necessary observational foundation upon which information about the stars as physical objects could be constructed. Positional astronomy practiced in the great national observatories was not about navigation or timekeeping; it was a way to standardize stellar observations and make them useful data for constructing theories of the stars themselves. For Herschel, the seeds of the new astronomy emerged from the practices of the old.

  16. Irradiation positions for fission-track dating in the University of Pavia TRIGA Mark II nuclear reactor

    International Nuclear Information System (INIS)

    Oddone, Massimo; Meloni, Sandro; Balestrieri, Maria Laura; Bigazzi, Giulio

    2002-01-01

    An irradiation position arranged is described in the present paper for fission-track dating in the Triga Mark II reactor of the University of Pavia. Fluence values determined using the NIST glass standard SRM 962a for fission-track dating and the traditional metal foils are compared. Relatively good neutron thermalization (φ th /φ f = 0.956) and lack of significant fluence spatial gradients are good factors for fission-track dating. Finally, international age standards (or putative age standards) irradiated in this new position yielded results consistent with independent reference ages. (author)

  17. WOCN Society and ASCRS Position Statement on Preoperative Stoma Site Marking for Patients Undergoing Colostomy or Ileostomy Surgery.

    Science.gov (United States)

    Salvadalena, Ginger; Hendren, Samantha; McKenna, Linda; Muldoon, Roberta; Netsch, Debra; Paquette, Ian; Pittman, Joyce; Ramundo, Janet; Steinberg, Gary

    2015-01-01

    Marking the optimal location for a stoma preoperatively enhances the likelihood of a patient's independence in stoma care, predictable pouching system wear times, and resumption of normal activities. Colon and rectal surgeons and certified ostomy nurses are the optimal clinicians to select and mark stoma sites, as this skill is a part of their education, practice, and training. However, these providers are not always available, particularly in emergency situations. The purpose of this position statement, developed by the Wound, Ostomy and Continence Nurses Society in collaboration with the American Society of Colon and Rectal Surgeons and the American Urological Association, is to provide a guideline to assist clinicians (especially those who are not surgeons or WOC nurses) in selecting an effective stoma site.

  18. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Obenauer, S.; Hermann, K.P.

    2012-01-01

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  19. CAD on personal computers

    International Nuclear Information System (INIS)

    Lee, Seong U; Cho, Cheol Ho; Ko, Il Du

    1990-02-01

    This book contains four studies of CAD on personal computers. The first thing is computer graphics in computer-aided design by Seong U Lee. The second thing is graphics primer and programming with Fortran by Seong U Lee. The third thing is application of Auto cad by Il Do Ko. The last thing is application of CAD in building construction design by Cheol Ho Cho.

  20. Easy Auto CAD

    International Nuclear Information System (INIS)

    Lee, Hyeon Jun

    1996-02-01

    This book explains Auto CAD easily, which introduces improved function in Auto CAD R 13, such as direct import and export of 3 DS pile, revised render order structure, and explanations of assist, view Draw, construct and modify. Next it gives descriptions of Auto CAD conception, application and system. The last part deals with line, arc, circle, ellipse, erase, undo, redo, redraw, line type, multi line, limits, zoom, move, copy, rotate, array, mirror, grid, snap, units, offset and poly line.

  1. CAD: Designs on Business.

    Science.gov (United States)

    Milburn, Ken

    1988-01-01

    Provides a general review of the field of Computer-Aided Design Software including specific reviews of "Autosketch,""Generic CADD,""Drafix 1 Plus,""FastCAD," and "Autocad Release 9." Brief articles include "Blueprint for Generation,""CAD for Every Department,""Ideas…

  2. AutoCAD workbook

    CERN Document Server

    Metherell, Phil

    1989-01-01

    AutoCAD Workbook helps new users learn the basics of AutoCad, providing guidance on most of the commonly used functions in which the program operates.This book discusses loading AutoCad and starting a drawing; drawing and erasing lines, circles, and arcs; and setting up the drawing environment. The topics on drawing and editing polylines; entering text and text styles; and layers, linetype, and color are also considered. This publication likewise covers creating and using blocks, hatching and extracting information, dimensioning drawings, 3D visualization, and plotting a drawing. Other

  3. MS AutoCad

    DEFF Research Database (Denmark)

    Andersen, Michael Rye; Heinicke, Hugo

    1996-01-01

    Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund for praktiskprojekter......Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund...

  4. CAD/CAM/CNC.

    Science.gov (United States)

    Domermuth, Dave; And Others

    1996-01-01

    Includes "Quick Start CNC (computer numerical control) with a Vacuum Filter and Laminated Plastic" (Domermuth); "School and Industry Cooperate for Mutual Benefit" (Buckler); and "CAD (computer-assisted drafting) Careers--What Professionals Have to Say" (Skinner). (JOW)

  5. Combining photogrammetry and CAD

    International Nuclear Information System (INIS)

    Borowsky, V.

    1993-01-01

    In nuclear power plants photogrammetry is being used to supply the data needed for setting up 3D CAD models. At Siemens, project handling has been made more economical by using photogrammetry and 3D CAD as a single process. Photogrammetry can be used for modelling extensive sections of the plant or small areas. Areas which particularly lend themselves to the use of photogrammetry are those with a high level of radiation or those yielding a large volume of data. (author)

  6. Application of Auto CAD

    International Nuclear Information System (INIS)

    Park, Yong Un; Kim, Geun Ho

    1989-05-01

    This book has introduction to use this book and explanation of application on Auto CAD, which includes, sub directories, batch files, robot wrist, design of standard paper, title block, robort weld room, robert wrist joint, PC board, plant sym, electro, PID, machines, robots, bubbles, plant, schema, Pid, plant assembly, robots, dim plant, PL-ASSM, plotting line weight control, symbol drawing joint, Auto CAD using script file, set up of workout · MNU, workout MNU, ACAD, LSP and workout · MNU.

  7. Identification of Drivers in Traffic Accidents and Determination of Passenger Position in a Vehicle by Finger Marks

    Directory of Open Access Journals (Sweden)

    Matej Trapečar

    2012-01-01

    Full Text Available The following paper aims to illustrate certain investigative activities in the forensic analysis and examination of the scene of traffic accidents. When a traffic accident occurs, the scene must be secured as soon as possible to enable professional and proper forensic investigation. Failure to secure the accident scene might result in losing or contaminating the traces, which makes it more difficult to prove or explain trace evidence in further procedure or even makes such evidence inadmissible. The topic is discussed from the viewpoint of crime scene examination, since analysing and investigating traffic accidents requires a great deal of expertise and attention of the investigators. Complex traffic accidents include feigned accidents, hit-and-run accidents as well as accidents in which the driver and passengers, dead or alive, need to be identified. In identifying the passengers, standard criminal investigation methods as well as police forensic and forensic medicine methods are followed. Such methods include confirming the identities with identity documents, other documents and vehicle ownership, fingerprints, biological traces, fibre traces, contact traces, traces of physical injuries on the driver and passengers, etc. According to the results obtained in fingerprint detection on human skin surfaces, this method can also be applied in confirming physical contact between the driver and the passengers in the accident, e.g. in the event of moving the victims and changing the scene of the accident.   Key words: traffic accidents, accident analysis, driver's identity, passengers' position, finger marks, human skin

  8. Application of Auto CAD 2000

    International Nuclear Information System (INIS)

    Kim, Hyeong Jun

    1999-11-01

    This book deals with basic of AutoCAD, beginning AutoCAD 2000, using design center of AutoCAD 2000, adding drawing element with design center, drawing lines, using 2D edit command, making layer, hatching, dimensioning, entering letters on the floor plan, making 3D object, practice of 3D command, edition of 3D object, making solid, rendering object, and using internet in AutoCAD 2000. This book is introduction of AutoCAD 2000 for beginner.

  9. Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.

    Science.gov (United States)

    Stawarczyk, Bogna; Özcan, Mutlu; Trottmann, Albert; Schmutz, Felix; Roos, Malgorzata; Hämmerle, Christoph

    2013-05-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown. The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks. Wear specimens (N=42, n=6) were made from 5 CAD/CAM resins: ZENO PMMA (ZP), artBloc Temp (AT), Telio CAD (TC), Blanc High-class (HC), CAD-Temp (CT); 1 manually polymerized resin: Integral esthetic press (negative control group, IEP); and 1 glass-ceramic: VITA Mark II (positive control group, VM2). The specimens for the wear resistance were aged in a thermomechanical loading machine (49 N, 1.67 Hz, 5/50°C) with human enamel antagonists. The material loss of all specimens before, during, and after aging was evaluated with a 3DS profilometer. The measured material loss data of all tested groups were statistically evaluated with linear mixed model analysis (a=.05). Manually polymerized resin showed significantly higher material wear (P<.001) than all other tested groups. Glass-ceramic showed significantly lower wear values (P<.001) than CAD/CAM resins ZP, AT, HC, CT, and IES. CAD/CAM resin TC was not significantly different from the positive control group. Glass-ceramic showed the highest enamel wear values (P<.001) of all tested resins. No differences were found in the enamel wear among all resins. The glass-ceramic group showed damage in the form of cracks on the worn enamel surface in 50% of specimens. CAD/CAM resins showed lower wear rates than those conventionally polymerized. Only one CAD/CAM resin, TC, presented material wear values comparable with glass-ceramic. The tested glass-ceramic developed cracks in the enamel antagonist and showed the highest enamel wear values of all other tested groups. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Modelled seasonal influenza mortality shows marked differences in risk by age, sex, ethnicity and socioeconomic position in New Zealand.

    Science.gov (United States)

    Khieu, Trang Q T; Pierse, Nevil; Telfar-Barnard, Lucy Frances; Zhang, Jane; Huang, Q Sue; Baker, Michael G

    2017-09-01

    Influenza is responsible for a large number of deaths which can only be estimated using modelling methods. Such methods have rarely been applied to describe the major socio-demographic characteristics of this disease burden. We used quasi Poisson regression models with weekly counts of deaths and isolates of influenza A, B and respiratory syncytial virus for the period 1994 to 2008. The estimated average mortality rate was 13.5 per 100,000 people which was 1.8% of all deaths in New Zealand. Influenza mortality differed markedly by age, sex, ethnicity and socioeconomic position. Relatively vulnerable groups were males aged 65-79 years (Rate ratio (RR) = 1.9, 95% CI: 1.9, 1.9 compared with females), Māori (RR = 3.6, 95% CI: 3.6, 3.7 compared with European/Others aged 65-79 years), Pacific (RR = 2.4, 95% CI: 2.4, 2.4 compared with European/Others aged 65-79 years) and those living in the most deprived areas (RR = 1.8, 95% CI: 1.3, 2.4) for New Zealand Deprivation (NZDep) 9&10 (the most deprived) compared with NZDep 1&2 (the least deprived). These results support targeting influenza vaccination and other interventions to the most vulnerable groups, in particular Māori and Pacific people and men aged 65-79 years and those living in the most deprived areas. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  11. Suunnitteluautomaatio CAD-ohjelmissa

    OpenAIRE

    Anttila, Juho

    2010-01-01

    Tässä työssä tutkittiin suunnitteluautomaation mahdollisuuksia cad-ohjelmissa. Työtä varten perehdyttiin useampaan cad-ohjelmaan ja tehtiin suurehko automaatti Vertex G4 alustalle, jonka kokemuksiin työn pohdinta pitkälti perustuu. Työ etenee yleisestä työkalujen esittelystä automatisoinnin teoriaan. Teoriassa pohditaan erilaisia tapoja ja tasoja miten automatisointia voidaan toteuttaa. Työn aihe oli kiinnostava, koska aiheesta on tehty melko vähän teoksia. Teoriapohdiskelun ohella esitettii...

  12. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  13. The VE/CAD synergism

    International Nuclear Information System (INIS)

    Sperling, R.B.

    1993-01-01

    Value Engineering (VE) and Computer-Aided Design (CAD) can be used synergistically to reduce costs and improve facilities designs. The cost and schedule impacts of implementing alternative design ideas developed by VE teams can be greatly reduced when the drawings have been produced with interactive CAD systems. To better understand the interrelationship between VE and CAD, the fundamentals of the VE process are explained; and example of a VE proposal is described and the way CAD drawings facilitated its implementation is illustrated

  14. AutoCAD 2014 and AutoCAD LT 2014

    CERN Document Server

    Gladfelter, Donnie

    2013-01-01

    A step-by-step tutorial introduction to AutoCAD As the only book to teach AutoCAD using a continuous tutorial which allows you to follow along sequentially or jump in at any exercise by downloading the drawing files, this Autodesk Official Press book is ideal for the AutoCAD novice. Industry expert and AutoCAD guru Donnie Gladfelter walks you through the powerful features of AutoCAD, provides you with a solid foundation of the basics, and shares the latest industry standards and techniques. The hands-on tutorial project inspired by real-world workflows that runs throughout the book

  15. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  16. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    International Nuclear Information System (INIS)

    Benzakoun, Joseph; Bommart, Sébastien; Coste, Joël; Chassagnon, Guillaume; Lederlin, Mathieu; Boussouar, Samia

    2016-01-01

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  17. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    Energy Technology Data Exchange (ETDEWEB)

    Benzakoun, Joseph, E-mail: benzakoun.joseph@gmail.com [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Bommart, Sébastien, E-mail: s-bommart@chu-montpellier.fr [CHU de Montpellier, 191 avenue du Doyen Gaston Giraud, 34000 Montpellier (France); INSERM U 1046, 371 avenue du Doyen G. Giraud, 34000 Montpellier (France); Coste, Joël, E-mail: joel.coste@htd.aphp.fr [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Chassagnon, Guillaume, E-mail: gchassagnon@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Cochin, Radiologie, 27 rue du Faubourg Saint Jacques, 75014 Paris (France); Lederlin, Mathieu, E-mail: mathieu.lederlin@chu-rennes.fr [CHU de Rennes, Radiologie, 2 Rue Henri le Guilloux, 35000 Rennes (France); Université de Rennes 1, 9 Rue Jean Macé, 35000 Rennes (France); Boussouar, Samia, E-mail: samiaboussouar@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Européen Georges Pompidou, 20 Rue Leblanc, 75015 Paris (France); and others

    2016-10-15

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  18. Structural design by CAD system

    International Nuclear Information System (INIS)

    Kim, Jhin Wung; Shim, Jae Ku; Kim, Sun Hoon; Kim, Dae Hong; Lee, Kyung Jin; Choi, Kyu Sup; Choi, In Kil; Lee, Dong Yong

    1988-12-01

    CAD systems are now widely used for the design of many engineering problems involving static, dynamic and thermal stress analyses of structures. In order to apply CAD systems to the structural analysis and design, the function of hardwares and softwares necessary for the CAD systems must be understood. The purpose of this study is to introduce the basic elements that are indispensible in the application of CAD systems to the analysis and design of structures and to give a thorough understanding of CAD systems to design engineers, so as to participate in the further technological developments of CAD systems. Due to the complexity and variety of the shape and size of the nowa-days structures, the need of new design technologies is growing for more efficient, accurate and economical design of structures. The application of CAD systems to structural engineering fields enables to improve structural engineering analysis and design technologies and also to obtain the standardization of the design process. An active introduction of rapidly developing CAD technologies will contribute to analyzing and designing structures more efficiently and reliably. Based on this report of the current status of the application of CAD systems to the structural analysis and design, the next goal is to develop the expert system which enables to perform the design of structures by CAD systems from the preliminary conceptual design to the final detail drawings automatically. (Author)

  19. AutoCAD / AutoCAD LT 2014 fundamentals metric

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The objective of AutoCAD/AutoCAD LT 2014 Fundamentals is to enable students to create a basic 2D drawing in the AutoCAD software. Even at this fundamental level, the AutoCAD software is one of the most sophisticated computer applications that you are likely to encounter. Therefore learning to use it can be challenging. To make the process easier and provide flexibility for instructors and students, the training guide is divided into two parts that can be taken independently.

  20. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  1. Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader

    International Nuclear Information System (INIS)

    Beyer, F.; Zierott, L.; Juergens, K.U.; Heindel, W.; Fallenberg, E.M.; Stoeckel, J.; Wormanns, D.

    2007-01-01

    The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR. (orig.)

  2. Easy Korean Auto CAD 14

    International Nuclear Information System (INIS)

    Lee, Jae Cheol

    1997-10-01

    This book introduces Auto CAD 14, which includes summary of basic things of Auto CAD 14, user interface for Auto CAD, basic drawing and advice, layer and set-up drawing, drawing with Auto CAD tools exactly, basic drawing of every thing, edit command, control of display, modeling and view ports of drawing space, various things drawing, writing letters, modification of floor plan, and check, block, X ref, lines and hatch, writing measurement, floor plan and OLE exchange of data, 3D floor plan, and rendering and presentation.

  3. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    International Nuclear Information System (INIS)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.; Napel, Sandy; Roos, Justus; Rubin, Geoffrey D.

    2010-01-01

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range of operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.

  4. 64006 CAD i Byggesektoren. Grundkursus

    DEFF Research Database (Denmark)

    Borchersen, Egil

    1998-01-01

    Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes.......Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes....

  5. Initial CAD investigations for NET

    International Nuclear Information System (INIS)

    Katz, F.; Leinemann, K.; Ludwig, A.; Marek, U.; Olbrich, W.; Schlechtendahl, E.G.

    1985-11-01

    This report summarizes the work done under contract no. 164/84-7/FU-D-/NET between the Commission of the European Communities and KfK during the period from June 1, 1984, through May 31, 1985. The following topics are covered in this report: Initial modelling of NET version NET2A, CAD system extension for remote handling studies, analysis of the CAD information structure, work related to the transfer of CAD information between KfK and the NET team. (orig.) [de

  6. AutoCAD 2014 essentials

    CERN Document Server

    Onstott, Scott

    2013-01-01

    Learn crucial AutoCAD tools and techniques with this Autodesk Official Press Book Quickly become productive using AutoCAD 2014 and AutoCAD LT 2014 with this full color Autodesk Official Press guide. This unique learning resource features concise, straightforward explanations and real-world, hands-on exercises and tutorials. Following a quick discussion of concepts and goals, each chapter moves on to an approachable hands-on exercise designed to reinforce real-world tactics and techniques. Compelling, full-color screenshots illustrate tutorial steps, and chapters conclude with relat

  7. Computer-aided pulmonary nodule detection. Performance of two CAD systems at different CT dose levels

    International Nuclear Information System (INIS)

    Hein, Patrick Alexander; Rogalla, P.; Klessen, C.; Lembcke, A.; Romano, V.C.

    2009-01-01

    Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median also positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p>0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems. (orig.)

  8. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    International Nuclear Information System (INIS)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    2009-01-01

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks

  9. Vragenlijst ter beoordeling van beeldschermtekenfuncties (CAD)

    NARCIS (Netherlands)

    Berndsen, M.B.; Vaas, F.

    1990-01-01

    Deze vragenlijst is een hulpmiddel om beeldscherm-tekenfuncties (CAD) waarbij gebruik wordt gemaakt van CAD-apparatuur, te beoordelen. Het gaat hierbij om functies waarin bij de hoofdtaken intensief met een beeldscherm wordt gewerkt, zoals het geval is bij de CAD-tekenaar, de CAD-instructeur en de

  10. Evaluation of Five Microcomputer CAD Packages.

    Science.gov (United States)

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…

  11. AutoCAD 2014 for dummies

    CERN Document Server

    Fane, Bill

    2013-01-01

    Find your way around AutoCAD 2014 with this full-color, For Dummies guide!Put away that pencil and paper and start putting the power of AutoCAD 2014 to work in your CAD projects and designs. From setting up your drawing environment to using text, dimensions, hatching, and more, this guide walks you through AutoCAD basics and provides you with a solid understanding of the latest CAD tools and techniques. You'll also benefit from the full-color illustrations that mirror exactly what you'll see on your AutoCAD 2014 screen and highlight the importance of AutoCAD's Mode

  12. When and why might a Computer Aided Detection (CAD) system interfere with visual search? An eye-tracking study

    Science.gov (United States)

    Drew, Trafton; Cunningham, Corbin; Wolfe, Jeremy

    2012-01-01

    Rational and Objectives Computer Aided Detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. Methods 47 naïve observers in two studies were asked to search for a target, embedded in 1/f2.4 noise while we monitored their eye-movements. For some observers, a CAD system marked 75% of targets and 10% of distractors while other observers completed the study without CAD. In Experiment 1, the CAD system’s primary function was to tell observers where the target might be. In Experiment 2, CAD provided information about target identity. Results In Experiment 1, there was a significant enhancement of observer sensitivity in the presence of CAD (t(22)=4.74, pCAD system were missed more frequently than equivalent targets in No CAD blocks of the experiment (t(22)=7.02, pCAD, but also no significant cost on sensitivity to unmarked targets (t(22)=0.6, p=n.s.). Finally, in both experiments, CAD produced reliable changes in eye-movements: CAD observers examined a lower total percentage of the search area than the No CAD observers (Ex 1: t(48)=3.05, pCAD signals do not combine with observers’ unaided performance in a straight-forward manner. CAD can engender a sense of certainty that can lead to incomplete search and elevated chances of missing unmarked stimuli. PMID:22958720

  13. TGeoCad: an Interface between ROOT and CAD Systems

    International Nuclear Information System (INIS)

    Luzzi, C; Carminati, F

    2014-01-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems

  14. TGeoCad: an Interface between ROOT and CAD Systems

    Science.gov (United States)

    Luzzi, C.; Carminati, F.

    2014-06-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems.

  15. Stretch Marks

    Science.gov (United States)

    ... completely without the help of a dermatologist or plastic surgeon. These doctors may use one of many types of treatments — from actual surgery to techniques like microdermabrasion and laser treatment — to reduce the appearance of stretch marks. These techniques are ...

  16. AutoCAD 2015 and AutoCAD LT 2015

    CERN Document Server

    Gladfelter, Donnie

    2014-01-01

    Learn AutoCAD by example with this tutorial-based guide from Autodesk Official Press Whether you are just starting out or an experienced user wanting to brush up on your skills, this Autodesk Official Press book provides you with concise explanations, focused examples, and step-by-step instructions through a hands-on tutorial project that runs throughout the book. As you progress through the project, the book introduces you to the Microsoft Windows-based AutoCAD interface and then guides you through basic commands and creating drawings. A downloadable file is available from the website so that

  17. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer

    International Nuclear Information System (INIS)

    Serago, Christopher F.; Buskirk, Steven J.; Igel, Todd C.; Gale, Ashley A.; Serago, Nicole E.; Earle, John D.

    2006-01-01

    Purpose: To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. Methods and Materials: Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. Results: With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 ± 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 ± 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 ± 3.1 mm, and the average intrafraction movement during treatment is 3.4 ± 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 ± 1.5 mm, and the average intrafraction movement during treatment is 2.1 ± 1.5 mm. Conclusions: Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization

  18. AutoCAD 2010 For Dummies

    CERN Document Server

    Byrnes, David

    2009-01-01

    AutoCAD is the hot computer-aided design software known for both its powerful tools and its complexity. AutoCAD 2010 for Dummies is the bestselling guide that walks you through this complicated program so you can build complex 3D technical drawings, edit like a pro, enter new dimensions, and plot with style. AutoCAD 2010 for Dummies helps you navigate the program, use the AutoCAD Design Center, create a basic layout and work with dimension, and put your drawings on the Internet. You'll soon be setting up the AutoCAD environment, using the AutoCAD Ribbon, creating annotation and dimension drawi

  19. AutoCAD 2008 for dummies

    CERN Document Server

    Byrnes, David

    2007-01-01

    A gentle, humorous introduction to this fearsomely complex software that helps new users start creating 2D and 3D technical drawings right awayCovers the new features and enhancements in the latest AutoCAD version and provides coverage of AutoCAD LT, AutoCAD''s lower-cost siblingTopics covered include creating a basic layout, using AutoCAD DesignCenter, drawing and editing, working with dimensions, plotting, using blocks, adding text to drawings, and drawing on the InternetAutoCAD is the leading CAD software for architects, engineers, and draftspeople who need to create detailed 2D and 3D tech

  20. Or CAD 9.1

    International Nuclear Information System (INIS)

    Lee, Seung Mu

    2000-02-01

    This book gives descriptions of Or CAD 9.1 with before drawing plan such as gaining Or CAD Demo CD, capture tools, making new design file, drawing structure, and setting design template, Drawings like making new drawing, finding parts, drawing lines, connecting line among the pages, and connecting parts using drawing structure, unstable multivibrator circle such as management of design file, power and ground connection, utility, beginning layout, single drawing, flat drawing, latch circuit, making a library, making a footprint, smart route and flash window.

  1. Computer-aided detection (CAD) in mammography: Does it help the junior or the senior radiologist?

    International Nuclear Information System (INIS)

    Balleyguier, Corinne; Kinkel, Karen; Fermanian, Jacques; Malan, Sebastien; Djen, Germaine; Taourel, Patrice; Helenon, Olivier

    2005-01-01

    Objectives: To evaluate the impact of a computer-aided detection (CAD) system on the ability of a junior and senior radiologist to detect breast cancers on mammograms, and to determine the potential of CAD as a teaching tool in mammography. Methods: Hundred biopsy-proven cancers and 100 normal mammograms were randomly analyzed by a CAD system. The sensitivity (Se) and specificity (Sp) of the CAD system were calculated. In the second phase, to simulate daily practice, 110 mammograms (97 normal or with benign lesions, and 13 cancers) were examined independently by a junior and a senior radiologist, with and without CAD. Interpretations were standardized according to BI-RADS classification. Sensitivity, Specificity, positive and negative predictive values (PPV, NPV) were calculated for each session. Results: For the senior radiologist, Se slightly improved from 76.9 to 84.6% after CAD analysis (NS) (one case of clustered microcalcifications case overlooked by the senior radiologist was detected by CAD). Sp, PPV and PNV did not change significantly. For the junior radiologist, Se improved from 61.9 to 84.6% (significant change). Three cancers overlooked by the junior radiologist were detected by CAD. Sp was unchanged. Conclusion: CAD mammography proved more useful for the junior than for the senior radiologist, improving sensitivity. The CAD system may represent a useful educational tool for mammography

  2. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    Science.gov (United States)

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p CAD (p = 0.0115), and Lava Ultimate (p CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the

  3. Lung nodule detection on chest CT: evaluation of a computer-aided detection (CAD) system

    International Nuclear Information System (INIS)

    Lee, In Jae; Gamsu, Gordon; Czum, Julianna; Johnson, Rebecca; Chakrapani, Sanjay; Wu, Ning

    2005-01-01

    To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results

  4. Cool-and Unusual-CAD Applications

    Science.gov (United States)

    Calhoun, Ken

    2004-01-01

    This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)

  5. CAD Skills Increased through Multicultural Design Project

    Science.gov (United States)

    Clemons, Stephanie

    2006-01-01

    This article discusses how students in a college-entry-level CAD course researched four generations of their family histories and documented cultural and symbolic influences within their family backgrounds. AutoCAD software was then used to manipulate those cultural and symbolic images to create the design for a multicultural area rug. AutoCAD was…

  6. CAD for CT colonography: toward a preparation-independent scheme

    International Nuclear Information System (INIS)

    Naeppi, J.

    2007-01-01

    Computer-aided detection (CAD) systems can be used to automatically detect and display the locations of polyps and masses in computed tomographic colonography (CTC) data for assisting radiologists' image interpretation. Rapid technical advancements over the last few years have established a fundamental CAD scheme for CTC that includes the steps of colon extraction, polyp detection, and false-positive (FP) reduction. Several CAD prototype systems have demonstrated clinically acceptable high polyp detection sensitivity with relatively few FP detections in cathartic CTC, and observer studies have demonstrated the potential benefit of such systems in improving the accuracy and consistency of radiologists' detection performance. Some CAD prototype systems have also demonstrated promising performance in reduced cathartic and non-cathartic CTC. Recent advancements suggest that CAD systems can soon be expected to provide a preparation-independent scheme that can yield consistently high detection sensitivity with moderately low FP rate not only with cathartic CTC protocols but over a wide range of cathartic, reduced cathartic, and non-cathartic CTC protocols. (orig.)

  7. AutoCAD platform customization VBA

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Boost productivity and streamline your workflow with expert AutoCAD: VBA programming instruction AutoCAD Platform Customization: VBA is the definitive guide to personalizing AutoCAD and the various programs that run on the AutoCAD platform, including AutoCAD Architecture, Civil 3D, Plant 3D, and more. Written by an Autodesk insider with years of customization and programming experience, this book features detailed discussions backed by real-world examples and easy-to-follow tutorials that illustrate each step in the personalization process. Readers gain expert guidance toward managing layout

  8. Prayer marks.

    Science.gov (United States)

    Abanmi, Abdullah A; Al Zouman, Abdulrahman Y; Al Hussaini, Husa; Al-Asmari, Abdulrahman

    2002-07-01

    Prayer marks (PMs) are asymptomatic, chronic skin changes that consist mainly of thickening, lichenification, and hyperpigmentation, and develop over a long period of time as a consequence of repeated, extended pressure on bony prominences during prayer. Three hundred and forty-nine Muslims and 24 non-Muslims were examined for the appearance of PMs at different body sites. The prospective study of 349 Muslims (both males and females) with regular praying habits showed the occurrence of PMs on specific locations, such as the forehead, knees, ankles, and dorsa of the feet, leading to dermatologic changes consisting of lichenification and hyperpigmentation. The incidence of PMs was significantly higher in males than in females. Older subjects (over 50 years of age) demonstrated a significantly higher frequency of lichenification and hyperpigmentation, suggesting that repeated pressure and friction for prolonged periods are the causative factors for the development of PMs. Histologic examination of skin biopsies from the affected sites showed compact orthokeratosis, hypergranulosis, dermal papillary fibrosis, and dermal vascularization. PMs were not associated with any risk of secondary complications, such as erythema, bullous formation, and infections. PMs are commonly occurring dermatologic changes in Muslims who pray for prolonged periods.

  9. Optical properties of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E

    2014-09-01

    To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network.

    Science.gov (United States)

    Albero, Alberto; Pascual, Agustín; Camps, Isabel; Grau-Benitez, María

    2015-10-01

    The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems. In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured. IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials. The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness.

  11. Performance and value of CAD-deficient pine- Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Bailian Li; Houmin Chang; Hasan Jameel

    2007-02-28

    x treatment interactions was found for any of the traits studied, in the fertilized plots, the effect of the cad-n1 allele on wood density was reduced. The study indicates that the cad-n1 allele could be a valuable gene to the pulp and paper industry for the purpose of enhancing pulp yields through increasing wood density. Stem growth and wood density associated with a mutant null (cad-n1) allele were examined in three 15-year-old loblolly pine diallel tests, established on two sites in the southern United States. In each diallel test, one or two cad-n1 heterozygous parents were crossed with five unrelated wild-type parents, to produce five or ten full-sib families. In all, 839 trees from 20 full-sib families in four genetic backgrounds (a cad-n1 heterozygote x 5 unrelated trees) were sampled, genotyped at the cad locus, and assessed for growth and wood density traits. In a combined analysis of all four genetic backgrounds, we found evidence for effects of increased wood density associated with the cad-n1 allele at age 15 (p=0.03) years and height growth at ages 6 (p=0.03) and 15 (p=0.005). There were large differences in the cad-n1 effects for the various growth and wood traits among the diallel tests. This variation may be due to either different genetic backgrounds among the parents of the different diallel tests, or for different growing environments at the field sites. Even though the cad-n1 effect on growth and wood density was significant across genetic backgrounds, the effect was variable among full-sib families within backgrounds. We speculate that certain wild-type alleles from second parents specifically interact with cad-n1 producing large positive effects. In addition, pleiotropic effects on growth and wood density appear to be associated with the cad-n1 allele. While substantial gains are possible through deployment of trees carrying cad-n1, these gains may be family-specific and should be verified for each cross through field testing.

  12. AutoCAD 2015 and AutoCAD LT 2015 bible

    CERN Document Server

    Finkelstein, Ellen

    2014-01-01

    The perfect reference for all AutoCAD users AutoCAD 2015 and AutoCAD LT 2015 Bible is the book you want to have close at hand to answer those day-to-day questions about this industry-leading software. Author and Autodesk University instructor Ellen Finkelstein guides readers through AutoCAD 2015 and AutoCAD LT 2015 with clear, easy-to-understand instruction and hands-on tutorials that allow even total beginners to create a design on their very first day. Although simple and fundamental enough to be used by those new to CAD, the book is so comprehensive that even Autodesk power u

  13. Use of McCad for the conversion of ITER CAD data to MCNP geometry

    International Nuclear Information System (INIS)

    Tsige-Tamirat, H.; Fischer, U.; Serikov, A.; Stickel, S.

    2008-01-01

    The program McCad provides a CAD interface for the Monte Carlo transport code MCNP. It is able to convert CAD data into MCNP input geometry description and provides GUI components for modeling, visualization, and data exchange. It performs sequences of tests on CAD data to check its validity and neutronics appropriateness including completion of the final MCNP model by void geometries. McCad has been used to convert a 40 deg. ITER torus sector CAD model to a suitable MCNP geometry model. Results of MCNP calculations performed to validate the converted geometry are presented

  14. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    Science.gov (United States)

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  15. WEBSITE EXECUTION OF CAD MODULES

    Directory of Open Access Journals (Sweden)

    A. A. Lyalinsky

    2013-01-01

    Full Text Available Web-based interface of modules that are part of the computer-aided design system in microelectronics is considered. The influence of several factors (available computer  memory, maximum allowed run time, degree of homogeneity of the software on the structure of the created system is investigated. Synchronous and asynchronous variants of interaction between control and executive parts are described. References on the systems that allow an access to applications in CAD microelectronics and are based on the principles discussed in this article are given.

  16. Viewing CAD Drawings on the Internet

    Science.gov (United States)

    Schwendau, Mark

    2004-01-01

    Computer aided design (CAD) has been producing 3-D models for years. AutoCAD software is frequently used to create sophisticated 3-D models. These CAD files can be exported as 3DS files for import into Autodesk's 3-D Studio Viz. In this program, the user can render and modify the 3-D model before exporting it out as a WRL (world file hyperlinked)…

  17. Computing Mass Properties From AutoCAD

    Science.gov (United States)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  18. BUILDING A PERGOLA IN CAD SYSTEMS

    Directory of Open Access Journals (Sweden)

    PRUNA Liviu

    2017-05-01

    Full Text Available In this paper the authors present a study and the conclusions they reached, regarding the possibility to automatically representing a pergola, when a CAD system is used. Also, a computer program, made by the authors is presented. This software was named Pergola and it offer the opportunity to sketch a pergola which cover a rectangular or circular area, when using the AutoCAD Architecture or AutoCAD computer program.

  19. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  20. Progress of computer-aided detection/diagnosis (CAD in dentistryCAD in dentistry

    Directory of Open Access Journals (Sweden)

    Akitoshi Katsumata

    2014-08-01

    CAD is also useful in the detection and evaluation of dental and maxillofacial lesions. Identifying alveolar bone resorption due to periodontitis and radiolucent jaw lesions (such as radicular and dentigerous cysts are important goals for CAD. CAD can be applied not only to panoramic radiography but also to dental cone-beam computed tomography (CBCT images. Linking of CAD and teleradiology will be an important issue.

  1. 3D CAD ON Qinshan CANDU project

    International Nuclear Information System (INIS)

    Goland, D.

    2000-01-01

    This paper briefly describe AECL's work in applying computer-aided engineering tools to the Qinshan CANDU project. The main thrust of this paper is to introduce the major CAD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CAD tools and their applications are also briefly introduced. (author)

  2. Sharing the learning activity using intelligent CAD

    DEFF Research Database (Denmark)

    Duffy, S. M.; Duffy, Alex

    1996-01-01

    In this paper the need for Intelligent Computer Aided Design (Int.CAD) to jointly support design and learning assistance is introduced. The paper focuses on presenting and exploring the possibility of realizing ''learning'' assistance in Int.CAD by introducing a new concept called Shared Learning...

  3. Positioning of the new trademark HEIN GAS in the liberalized gas market; Die Neupositionierung der Marke HEIN GAS im liberalisierten Gasmarkt

    Energy Technology Data Exchange (ETDEWEB)

    Unbehaun, C. [HEIN GAS Hamburger Gaswerke GmbH, Hamburg (Germany)

    2000-10-01

    Trademarks are getting increasingly important as a marketing factor in natural gas supply. The HEIN GAS company aims at becoming one of the top utilities in northern Germany. The contribution shows how marketing research and strategies are employed to achieve this. [German] Die kommunikativen Aktivitaeten aller Gasunternehmen werden zukuenftig einen entscheidenden Marktfaktor darstellen, um Geschaefts- und Privatkunden zu halten bzw. weitere zu gewinnen. Gerade im deutschen Gasmarkt, der durch austauschbare Produkte gekennzeichnet ist, kommt der Marke besondere Bedeutung zu. Der Preis ist zwar ein wichtiger, aber nicht immer allein entscheidendeer Wettbewerbsfaktor. Fuer das Unternehmen HEIN GAS heisst dies, auch im kommunikativen Wettbewerb zu bestehen. Es wird der Weg beschrieben, HEIN GAS zu einer Fuehrungsmarke im norddeutschen Waermemarkt zu etablieren. Dabei wird aufgezeigt, wie die Ergebnisse durch Marktforschung ueberprueft werden.

  4. Spatial dependence of the void coefficient in the interstitial coolant channel positions of a stainless steel-clad TRIGA Mark I core

    International Nuclear Information System (INIS)

    Spriggs, Gregory D.; Nelson, George W.; Doane, Harry J.

    1982-01-01

    A new top grid plate was manufactured and installed in the U of A TRIGA. The new grid plate was identical to the old grid plate with respect to the fuel element array, but included two minor modifications; 1) 3/8'' holes were drilled in six interstitial positions between fuel element rings to allow for insertion of a small diameter void rod for void coefficient measurements in the coolant channels, and 2) flux wire holes were drilled in all remaining interstitial positions. The purpose of this report is to update the previously reported void coefficient measurements with data taken in one of the coolant channel positions

  5. Grinding damage assessment for CAD-CAM restorative materials.

    Science.gov (United States)

    Curran, Philippe; Cattani-Lorente, Maria; Anselm Wiskott, H W; Durual, Stéphane; Scherrer, Susanne S

    2017-03-01

    To assess surface/subsurface damage after grinding with diamond discs on five CAD-CAM restorative materials and to estimate potential losses in strength based on crack size measurements of the generated damage. The materials tested were: Lithium disilicate (LIT) glass-ceramic (e.max CAD), leucite glass-ceramic (LEU) (Empress CAD), feldspar ceramic (VM2) (Vita Mark II), feldspar ceramic-resin infiltrated (EN) (Enamic) and a composite reinforced with nano ceramics (LU) (Lava Ultimate). Specimens were cut from CAD-CAM blocs and pair-wise mirror polished for the bonded interface technique. Top surfaces were ground with diamond discs of respectively 75, 54 and 18μm. Chip damage was measured on the bonded interface using SEM. Fracture mechanics relationships were used to estimate fracture stresses based on average and maximum chip depths assuming these to represent strength limiting flaws subjected to tension and to calculate potential losses in strength compared to manufacturer's data. Grinding with a 75μm diamond disc induced on a bonded interface critical chips averaging 100μm with a potential strength loss estimated between 33% and 54% for all three glass-ceramics (LIT, LEU, VM2). The softer materials EN and LU were little damage susceptible with chips averaging respectively 26μm and 17μm with no loss in strength. Grinding with 18μm diamond discs was still quite detrimental for LIT with average chip sizes of 43μm and a potential strength loss of 42%. It is essential to understand that when grinding glass-ceramics or feldspar ceramics with diamond discs surface and subsurface damage are induced which have the potential of lowering the strength of the ceramic. Careful polishing steps should be carried out after grinding especially when dealing with glass-ceramics. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. The effect of milling and postmilling procedures on the surface roughness of CAD/CAM materials.

    Science.gov (United States)

    Mota, Eduardo Gonçalves; Smidt, Laura Nunes; Fracasso, Lisiane Martins; Burnett, Luiz Henrique; Spohr, Ana Maria

    2017-11-12

    The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures. Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL. Ten flat samples of each material were obtained. The surface roughness (Ra) test was performed before and after milling, crystallization, polishing, and glaze when indicated, followed by SEM and AFM analysis. Data were submitted to one-way ANOVA with repeated measures and the Tukey HSD test (α = 0.05). The milling step significantly increased the roughness of all the tested materials (P CAD and Suprinity) were more suitable to roughness than the other tested materials (P CAD/CAM materials, that is, fully sintered, should be only hand polished. The glaze step can be suppressed resulting in time saving. However, the glaze step in soft-milling lithium disilicate is imperative. © 2017 Wiley Periodicals, Inc.

  7. Functional characterization of a cadmium resistance operon in Staphylococcus aureus ATCC12600: CadC does not function as a repressor.

    Science.gov (United States)

    Hoogewerf, Arlene J; Dyk, Lisa A Van; Buit, Tyler S; Roukema, David; Resseguie, Emily; Plaisier, Christina; Le, Nga; Heeringa, Lee; Griend, Douglas A Vander

    2015-02-01

    Sequencing of a cadmium resistance operon from a Staphylococcus aureus ATCC12600 plasmid revealed that it is identical to a cadCA operon found in MRSA strains. Compared to plasmid-cured and cadC-mutant strains, cadC-positive ATCC12600 cells had increased resistance to cadmium (1 mg ml(-1) cadmium sulfate) and zinc (4 mg ml(-1) zinc sulfate), but not to other metal ions. After growth in media containing 20 µg ml(-1) cadmium sulfate, cadC-mutant cells contained more intracellular cadmium than cadC-positive ATCC12600 cells, suggesting that cadC absence results in impaired cadmium efflux. Electrophoretic mobility shift assays were performed with CadC proteins encoded by the S. aureus ATCC12600 plasmid and by the cadC gene of pI258, which is known to act as a transcriptional repressor and shares only 47% protein sequence identity with ATCC12600 CadC. Mobility shifts occurred when pI258 CadC protein was incubated with the promoter DNA-regions from the pI258 and S. aureus ATCC12600 cadCA operons, but did not occur with S. aureus ATCC12600 CadC protein, indicating that the ATCC12600 CadC protein does not interact with promoter region DNA. This cadCA operon, found in MRSA strains and previously functionally uncharacterized, increases resistance to cadmium and zinc by an efflux mechanism, and CadC does not function as a transcriptional repressor. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Successfully converting mine maps to CAD

    Energy Technology Data Exchange (ETDEWEB)

    Munn, M.D. (Image Conversion Services, Inc., Salt Lake City, UT (USA))

    1991-03-01

    Procedures followed by computer service bureaus to convert paper drawing to digital files that can be used by CAD systems are described. The conversion involves laser scanning of original drawings to produce an 'inactive image' (a form suitable for many drawings that do not need to be changed). Using optical character recognition software the image is then vectorized or converted from raster format to geometric elements usable in a CAD system. The vectorized image can then be cleaned up corrected and changed at the CAD workstation. 4 figs.

  9. Dataudveksling mellem CAD og CAE programmer

    DEFF Research Database (Denmark)

    Sørensen, Torben; Conrad, Finn

    2001-01-01

    Når mange forskelligartede programmer benyttes til beregninger og anden databehandling på samme modeller er det nødvendig at udveksle modellerne mellem disse forskellige programmer. Biler og skibe bliver f.eks. typisk designet i 3D CAD systemer, mens CAD modellerne herefter anvendes i andre...... dedikerede IT-systemer i forbindelse montageplanlægningen, svejseplanlægningen, robotprogrammeringen mm. der således her et behov for at udveksle CAD modellen mellem de forskellige programmer. Udveksling af information mellem forskellige programmer og systemer kræver såvel en fælles specifikation af det...

  10. AutoCAD platform customization autolisp

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Customize and personalize programs built on the AutoCAD platform AutoLISP is the key to unlocking the secrets of a more streamlined experience using industry leading software programs like AutoCAD, Civil 3D, Plant 3D, and more. AutoCAD Platform Customization: AutoLISP provides real-world examples that show you how to do everything from modifying graphical objects and reading and setting system variables to communicating with external programs. It also features a resources appendix and downloadable datasets and customization examples-tools that ensure swift and easy adoption. Find out how to r

  11. The Role of CAD in Enterprise Integration Process

    Directory of Open Access Journals (Sweden)

    M. Ota

    2004-01-01

    Full Text Available This article deals with the problem of the mutual influence between software systems used in enterprise environment and enterprise integration processes. The position of CAD data and CAx systems in the integrated environment of manufacturing enterprises is clarified. As a consequence, the key role of CAx systems used in those companies is emphasized. It is noted that the integration of CAD data is nowadays only on a secondary level, via primarily integrated PDM systems. This limitation is a reason why we are developing a unified communication model focused on product-oriented data. Our approach is based on Internet technologies, so we believe that is independent enough. The proposed system of communication is based on a simple request-replay dialogue. The structure of this model is open and extensible, but we assume supervision supported by an Internet portal.

  12. Triple vessel coronary artery disease presenting as a markedly positive stress electrocardiographic test and a negative SPECT-TL scintigram: a case of balanced Ischemia

    Directory of Open Access Journals (Sweden)

    Eyal Herzog

    2011-09-01

    Full Text Available The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. We present a case of an 81- year old post-menopausal female who presented to her primary care physician for evaluation of a 6-week dyspnea on exertion and was referred to our institution for exercise stress test with Thallium SPECT with the objective of ruling out coronary artery disease and identifying possible areas of myocardial ischemia. The resting electrocardiogram was unremarkable and stress test evaluation was made. The patient was admitted to the cardiac care unit and coronary artery bypass grafting was successfully performed. The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. Patients undergoing stress tests with these characteristics should undergo careful evaluation and a high level of suspicion should be adopted for further diagnostic assessment of coronary artery disease.

  13. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    Science.gov (United States)

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  14. AutoCAD 2008 and AutoCAD LT 2008 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    "Whether you're new to AutoCAD or a veteran, you will undoubtedly find this book to be an excellent resource."-- Abhi Singh, AutoCAD Product Manager, Autodesk, Inc.Here's the book that makes AutoCAD approachableEven the people at Autodesk look to Ellen Finkelstein for AutoCAD training, so who better to teach you about AutoCAD 2008? This comprehensive guide brings veterans up to speed on AutoCAD updates and takes novices from the basics to programming in AutoLISP(r) and VBA. Every feature is covered in a logical order, and with the Quick Start chapter, you'll be creating drawings on your very f

  15. Line Generalization and AutoCAD Map

    Directory of Open Access Journals (Sweden)

    Nada Vučetić

    2001-01-01

    Full Text Available The paper offers the results of original research made on the application of AutoCAD Map in line generalisation. The differences and similarities have been found out between the Douglas-Peucker method and the method of line simplification that is incorporated in AutoCAD Map. There have been also the inaccuracies found out in AutoCAD Map manual relating to the issues of buffer width and tolerance, and the line width before and after simplification. The paper gives recommendations about pseudo nodes dissolving. It has been noticed that AutoCAD Map simplification method is not independent of the order of points. The application of the method is illustrated by an example of coastal line of Istria.

  16. Microcomputer Simulated CAD for Engineering Graphics.

    Science.gov (United States)

    Huggins, David L.; Myers, Roy E.

    1983-01-01

    Describes a simulated computer-aided-graphics (CAD) program at The Pennsylvania State University. Rationale for the program, facilities, microcomputer equipment (Apple) used, and development of a software package for simulating applied engineering graphics are considered. (JN)

  17. AutoCAD-To-NASTRAN Translator Program

    Science.gov (United States)

    Jones, A.

    1989-01-01

    Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).

  18. A Virtual CAD Model of the LHC

    CERN Document Server

    Chemli, S; Messerli, R; Muttoni, Y; Prin, H; Van Uytvinck, E

    2000-01-01

    Integrating the large and complex LHC machine into the existing LEP tunnel is a major challenge. Space was not really a problem to fit the LEP machine into its tunnel, but LHC cryostats are much larger than the LEP quadrupoles and the external cryogenic line fills even more the tunnel. Space problems lead to small clearances. Possible conflicts, or at least the most penalising ones, between installed equipment or with transport, must be solved beforehand in order to avoid unacceptable delays and extra costs during the installation. Experience gained with LEP has already shown the help that Computer-Aided Engineering tools could provide for the integration. A virtual model of the LHC is presently prepared. The actual LEP tunnel, known with a quite good accuracy (centimetre level), has been modelled and all the elements of the machine constructed as 3D objects with the CAD system are positioned accurately on the basis of data generated from the theoretical definition. These layouts are used to generate the refe...

  19. Toothbrushing alters the surface roughness and gloss of composite resin CAD/CAM blocks.

    Science.gov (United States)

    Kamonkhantikul, Krid; Arksornnukit, Mansuang; Lauvahutanon, Sasipin; Takahashi, Hidekazu

    2016-01-01

    This study investigated the surface roughness and gloss of composite resin CAD/CAM blocks after toothbrushing. Five composite resin blocks (Block HC, Cerasmart, Gradia Block, KZR-CAD Hybrid Resin Block, and Lava Ultimate), one hybrid ceramic (Vita Enamic), one feldspar ceramic (Vitablocs Mark II), one PMMA block (Telio CAD), and one conventional composite resin (Filtek Z350 XT) were evaluated. Surface roughness (Ra) and gloss were determined for each group of materials (n=6) after silicon carbide paper (P4000) grinding, 10k, 20k, and 40k toothbrushing cycles. One-way repeated measures ANOVA indicated significant differences in the Ra and gloss of each material except for the Ra of GRA. After 40k toothbrushing cycles, the Ra of BLO and TEL showed significant increases, while CER, KZR, ULT, and Z350 showed significant decreases. GRA, ENA, and VIT maintained their Ra. All of the materials tested, except CER, demonstrated significant decreases in gloss after 40k toothbrushing cycles.

  20. Virtual colonoscopy: effect of computer-assisted detection (CAD) on radiographer performance

    International Nuclear Information System (INIS)

    Burling, D.; Moore, A.; Marshall, M.; Weldon, J.; Gillen, C.; Baldwin, R.; Smith, K.; Pickhardt, P.; Honeyfield, L.; Taylor, S.

    2008-01-01

    Aim: To investigate the effect of a virtual colonoscopy (VC) computed-assisted detection (CAD) system on polyp detection by trained radiographers. Materials and methods: Four radiographers trained in VC interpretation and utilization of CAD systems read a total of 62 endoscopically validated VC examinations containing 150 polyps (size range 5-50 mm) in four sessions, recording any polyps found and the examination interpretation time, first without and then with the addition of CAD as a 'second reader'. After a temporal separation of 6 weeks to reduce recall bias, VC examinations were re-read using 'concurrent reader' CAD. Interpretation times, polyp detection, and number of false-positives were compared between the different reader paradigms using paired t and paired exact tests. Results: Overall, use of 'second reader' CAD significantly improved polyp detection by 12% (p < 0.001, CI 6%,17%)) from 48 to 60%. There was no significant improvement using CAD as a concurrent reader (p = 0.20; difference of 7%, CI -3%, 16%) and no significant overall difference in recorded false-positives with second reader or concurrent CAD paradigms compared with unassisted reading (p = 0.25 and 0.65, respectively). The mean interpretation time was 21.7 min for unassisted reading, 29.6 (p < 0.001) min for second reader and 19.1 min (p = 0.12) for concurrent reading paradigms. Conclusion: CAD, when used as a second reader, can significantly improve radiographer reading performance with only a moderate increase in interpretation times

  1. Chairside CAD/CAM materials. Part 3: Cyclic fatigue parameters and lifetime predictions.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Valladares, Diana; Petschelt, Anselm; Lohbauer, Ulrich

    2018-06-01

    Chemical and mechanical degradation play a key role on the lifetime of dental restorative materials. Therefore, prediction of their long-term performance in the oral environment should base on fatigue, rather than inert strength data, as commonly observed in the dental material's field. The objective of the present study was to provide mechanistic fatigue parameters of current dental CAD/CAM materials under cyclic biaxial flexure and assess their suitability in predicting clinical fracture behaviors. Eight CAD/CAM materials, including polycrystalline zirconia (IPS e.max ZirCAD), reinforced glasses (Vitablocs Mark II, IPS Empress CAD), glass-ceramics (IPS e.max CAD, Suprinity PC, Celtra Duo), as well as hybrid materials (Enamic, Lava Ultimate) were evaluated. Rectangular plates (12×12×1.2mm 3 ) with highly polished surfaces were prepared and tested in biaxial cyclic fatigue in water until fracture using the Ball-on-Three-Balls (B3B) test. Cyclic fatigue parameters n and A* were obtained from the lifetime data for each material and further used to build SPT diagrams. The latter were used to compare in-vitro with in-vivo fracture distributions for IPS e.max CAD and IPS Empress CAD. Susceptibility to subcritical crack growth under cyclic loading was observed for all materials, being more severe (n≤20) in lithium-based glass-ceramics and Vitablocs Mark II. Strength degradations of 40% up to 60% were predicted after only 1 year of service. Threshold stress intensity factors (K th ) representing the onset of subcritical crack growth (SCG), were estimated to lie in the range of 0.37-0.44 of K Ic for the lithium-based glass-ceramics and Vitablocs Mark II and between 0.51-0.59 of K Ic for the other materials. Failure distributions associated with mechanistic estimations of strength degradation in-vitro showed to be useful in interpreting failure behavior in-vivo. The parameter K th stood out as a better predictor of clinical performance in detriment to the SCG n

  2. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement.

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin; Tulga, Ayça

    2017-12-01

    To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) ( P CAD/CAM restorative materials was modified after treatments. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

  3. Influence of CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes.

    Science.gov (United States)

    Pabst, A M; Walter, C; Grassmann, L; Weyhrauch, M; Brüllmann, D D; Ziebart, T; Scheller, H; Lehmann, K M

    2014-05-01

    The aim of this study was to analyze the influence of four CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase (ADK) release of human gingival fibroblasts (HGF) and oral keratinocytes (HOK). HGF and HOK were cultured on disc-shaped CAD/CAM all-ceramic materials (e.max CAD LT, e.max CAD HT, Empress CAD and Mark II) and on discs made of tissue culture polystyrene surface (TCPS) serving as control. Cell viability was analyzed by using an MTT assay, and migration ability was investigated by a scratch assay. A ToxiLight assay has been performed to analyze the effect of all-ceramic materials on ADK release and cell apoptosis. At MTT assay for HGF, no significant decrease of cell viability could be detected at all points of measurement (p each > 0.05), while HOK demonstrated a significant decrease in cell viability especially on Empress CAD and Mark II at each point of measurement (p each materials at all points of measurement (between -36 % and -71 %; p each ceramic materials could be investigated. This study disclosed significant differences in cell viability and migration ability of HGF and HOK on CAD/CAM all-ceramic materials. CAD/CAM all-ceramic materials can influence oral cell lines responsible for soft tissue creation which may affect the esthetic outcome.

  4. Sophistication and integration of plant engineering CAD-CAE systems

    International Nuclear Information System (INIS)

    Yoshinaga, Toshiaki; Hanyu, Masaharu; Ota, Yoshimi; Kobayashi, Yasuhiro.

    1995-01-01

    In respective departments in charge of basic planning, design, manufacture, inspection and construction of nuclear power plants, by the positive utilization of CAD/CAE system, efficient workings have been advanced. This time, the plant integrated CAE system wich heightens the function of these individual systems, and can make workings efficient and advanced by unifying and integrating them was developed. This system is composed of the newly developed application system and the data base system which enables the unified management of engineering data and high speed data conversion in addition to the CAD system for three-dimensional plant layout planning. On the basis of the rich experience and the proposal of improvement of designers by the application of the CAD system for three-dimensional plant layout planning to actual machines, the automation, speed increase and the visualization of input and output by graphical user interface (GUI) in the processing of respective applications were made feasible. As the advancement of plant CAE system, scenic engineering system, integrated layout CAE system, electric instrumentation design CAE system and construction planning CAE system are described. As for the integration of plant CAE systems, the integrated engineering data base, the combination of plant CAE systems, and the operation management in the dispersed environment of networks are reported. At present, Hitachi Ltd. exerts efforts for the construction of atomic energy product in formation integrated management system as the second stage of integration. (K.I.)

  5. Adaptação do Bird Mark 7 para oferta de pressão positiva contínua nas vias aéreas em ventilação não-invasiva: estudo em modelo mecânico Adapting the Bird Mark 7 to deliver noninvasive continuous positive airway pressure: a bench study

    Directory of Open Access Journals (Sweden)

    Beatriz Mayumi Kikuti

    2008-03-01

    Full Text Available OBJETIVO: Testar a eficiência da adaptação do ventilador Bird Mark 7 para oferecer pressão positiva contínua nas vias aéreas, conhecida como continuous positive airway pressure (CPAP em inglês, em ventilação não-invasiva. MÉTODOS: Estudo experimental utilizando um modelo mecânico do sistema respiratório. O Bird Mark 7 foi alimentado com 400 e 500 kPa e foi testado em CPAP de 5, 10 e 15 cmH2O. Para avaliar a eficiência da adaptação foram analisados os seguintes variáveis: diferença entre a CPAP pré-determinada e a CPAP realmente atingida (CPAPreal; área da pressão da via aérea sob o nível de CPAP ajustado (ÁREA CPAP; e volume corrente gerado. RESULTADOS: A adaptação do Bird Mark 7 para oferecer CPAP em ventilação não-invasiva conseguiu atingir o volume corrente esperado em todas as situações de esforço inspiratório (normal ou elevado, pressão de alimentação (400 ou 500 kPa e valor de CPAP (5, 10 ou 15 cmH2O. Para os CPAPs de 5 e 10 cmH2O, o CPAPreal foi muito próximo do pré-determinado, e a ÁREA CPAP teve valor próximo de zero. Para o CPAP de 15 cmH2O, o CPAPreal ficou abaixo do pré-determinado, e a ÁREA CPAP teve valor elevado. CONCLUSÃO: A eficiência da adaptação do Bird Mark 7 para oferecer CPAP em ventilação não-invasiva foi boa para os valores de CPAP de 5 e 10 cmH2O e insuficiente para CPAP de 15 cmH2O. Se adaptado como em nosso estudo, o Bird Mark 7 pode ser uma opção para oferta de CPAP até 10 cmH2O em locais onde equipamentos de ventilação não-invasiva são escassos ou inexistentes.OBJECTIVE: To test the efficiency of the Bird Mark 7 ventilator adapted to deliver continuous positive airway pressure (CPAP in noninvasive positive pressure ventilation. METHODS: This was an experimental study using a mechanical model of the respiratory system. A Bird Mark 7 ventilator was supplied with 400 and 500 kPa and tested at CPAP of 5, 10 and 15 cmH2O. The following variables were analyzed

  6. Improved algorithms and advanced features of the CAD to MC conversion tool McCad

    International Nuclear Information System (INIS)

    Lu, L.; Fischer, U.; Pereslavtsev, P.

    2014-01-01

    Highlights: •The latest improvements of the McCad conversion approach including decomposition and void filling algorithms is presented. •An advanced interface for the materials editing and assignment has been developed and added to the McCAD GUI. •These improvements have been tested and successfully applied to DEMO and ITER NBI (Neutral Beam Injector) applications. •The performance of the CAD model conversion process is shown to be significantly improved. -- Abstract: McCad is a geometry conversion tool developed at KIT to enable the automatic bi-directional conversions of CAD models into the Monte Carlo (MC) geometries utilized for neutronics calculations (CAD to MC) and, reversed (MC to CAD), for visualization purposes. The paper presents the latest improvements of the conversion algorithms including improved decomposition, void filling and an advanced interface for the materials editing and assignment. The new implementations and features were tested on fusion neutronics applications to the DEMO and ITER NBI (Neutral Beam Injector) models. The results demonstrate greater stability and enhanced efficiency of McCad conversion process

  7. AutoCAD 2012 and AutoCAD LT 2012 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    The latest version of this perennial favorite, in-depth, reference-tutorial This top-selling book has been updated by AutoCAD guru and author Ellen Finkelstein to provide you with the very latest coverage of both AutoCAD 2012 and AutoCAD LT 2012. It begins with a Quick Start tutorial, so you start creating right away. From there, the book covers so much in-depth material on AutoCAD that it is said that even Autodesk employees keep this comprehensive book at their desks. A DVD is included that features before-and-after drawings of all the tutorials and plenty of great examples from AutoCAD prof

  8. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    Science.gov (United States)

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane

  9. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    -CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Improving the radiologist–CAD interaction: designing for appropriate trust

    International Nuclear Information System (INIS)

    Jorritsma, W.; Cnossen, F.; Ooijen, P.M.A. van

    2015-01-01

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist–CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the interaction between radiologists and the CAD system is not optimal. An important factor in the interaction between humans and automated aids (such as CAD) is trust. Suboptimal performance of the human–automation team is often caused by an inappropriate level of trust in the automation. In this review, we examine the role of trust in the radiologist–CAD interaction and suggest ways to improve the output of the CAD system so that it allows radiologists to calibrate their trust in the CAD system more effectively. Observer studies of the CAD systems show that radiologists often have an inappropriate level of trust in the CAD system. They sometimes under-trust CAD, thereby reducing its potential benefits, and sometimes over-trust it, leading to diagnostic errors they would not have made without CAD. Based on the literature on trust in human–automation interaction and the results of CAD observer studies, we have identified four ways to improve the output of CAD so that it allows radiologists to form a more appropriate level of trust in CAD. Designing CAD systems for appropriate trust is important and can improve the performance of the radiologist–CAD team. Future CAD research and development should acknowledge the importance of the radiologist–CAD interaction, and specifically the role of trust therein, in order to create the perfect artificial partner for the radiologist. This review focuses on the role of trust in the radiologist–CAD interaction. The aim of the review is to encourage CAD developers to design for appropriate trust and thereby improve the performance of the radiologist–CAD team. - Highlights: • Radiologists often have an inappropriate

  11. Development of integrated CAD system PV-1

    International Nuclear Information System (INIS)

    Miyamoto, Hitoshi; Ogawa, Kazuya; Shibata, Masayoshi.

    1997-01-01

    An integrated CAD system for pressure vessels, such as heat exchangers, drums, towers, jacketed vessels, and tanks, has been developed. The system is operated by MS-DOS personal computers combined in a LAN. Pressure vessel designers can work watching using the computer display because the system automatically manages design work, on a common data base. The project team members in other sections, such as production, cost control, and design, have the same data concurrently. Personal computers unite the 3D CAD system, and the generated design with detail dimensions and shapes is stored in the 3D CAD system automatically. The system has promoted higher design quality and greatly reduced design cost. (author)

  12. Absorbing CAD system geometries into GEANT

    International Nuclear Information System (INIS)

    Womersley, J.; Dragovitsch, P.; Youssef, S.

    1991-01-01

    The simulation community has for many years discussed the possibility of direct conversion of geometrical detector models from computer- aided design and engineering systems (CAD systems) to the simulation packages (which we shall assume means GEANT). This would allow fast and simultaneous optimization of the physics performance and structural integrity of detector designs. The benefit that this would offer is the avoidance of such problems as the late discovery of the rather thick cryostats in the D-Zero detector. Recent progress in the absorption of CAD geometries into GEANT models is reviewed, including descriptions of the additions to the I-DEAS solid modeller package developed for the EMPACT SSC proposal, the COGENT CAD-to-GEANT interpreter developed by Quantum Research Services, and the OCTAGON package for representing arbitrary shapes in GEANT. Likely future directions of development are described. 2 refs., 7 figs

  13. AutoCAD platform customization user interface and beyond

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Make AutoCAD your own with powerful personalization options Options for AutoCAD customization are typically the domain of administrators, but savvy users can perform their own customizations to personalize AutoCAD. Until recently, most users never thought to customize the AutoCAD platform to meet their specific needs, instead leaving it to administrators. If you are an AutoCAD user who wants to ramp up personalization options in your favorite software, AutoCAD Platform Customization: User Interface and Beyond is the perfect resource for you. Author Lee Ambrosius is recognized as a leader in Au

  14. MEBT design for C-ADS

    International Nuclear Information System (INIS)

    Geng Huiping; Tang Jingyu; Li Zhihui; Yan Fang; Ouyang Huafu

    2012-01-01

    In proton accelerators, the Medium Energy Beam Transport (MEBT) line is an essential part for transporting and matching the beam from the RFQ to the next type of accelerating structure. The MEBT is also very important in machine commissioning and tuning. The design of the China Accelerator Driven System is making great progress. The C-ADS project is composed of two independent injectors; therefore, two MEBT lines will be designed independently. In this paper, we will give a detailed description of the MEBT design (including parameter selection and beam dynamics calculation) for the injector I of the C-ADS project. (authors)

  15. A comparison of computer-assisted detection (CAD) programs for the identification of colorectal polyps: performance and sensitivity analysis, current limitations and practical tips for radiologists.

    Science.gov (United States)

    Bell, L T O; Gandhi, S

    2018-06-01

    To directly compare the accuracy and speed of analysis of two commercially available computer-assisted detection (CAD) programs in detecting colorectal polyps. In this retrospective single-centre study, patients who had colorectal polyps identified on computed tomography colonography (CTC) and subsequent lower gastrointestinal endoscopy, were analysed using two commercially available CAD programs (CAD1 and CAD2). Results were compared against endoscopy to ascertain sensitivity and positive predictive value (PPV) for colorectal polyps. Time taken for CAD analysis was also calculated. CAD1 demonstrated a sensitivity of 89.8%, PPV of 17.6% and mean analysis time of 125.8 seconds. CAD2 demonstrated a sensitivity of 75.5%, PPV of 44.0% and mean analysis time of 84.6 seconds. The sensitivity and PPV for colorectal polyps and CAD analysis times can vary widely between current commercially available CAD programs. There is still room for improvement. Generally, there is a trade-off between sensitivity and PPV, and so further developments should aim to optimise both. Information on these factors should be made routinely available, so that an informed choice on their use can be made. This information could also potentially influence the radiologist's use of CAD results. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. SU-G-JeP3-02: Comparison of Magnitude and Frequency of Patient Positioning Errors in Breast Irradiation Using AlignRT 3D Optical Surface Imaging and Skin Mark Techniques

    International Nuclear Information System (INIS)

    Yao, R; Chisela, W; Dorbu, G

    2016-01-01

    Purpose: To evaluate clinical usefulness of AlignRT (Vision RT Ltd., London, UK) in reducing patient positioning errors in breast irradiation. Methods: 60 patients undergoing whole breast irradiation were selected for this study. Patients were treated to the left or right breast lying on Qfix Access breast board (Qfix, Avondale, PA) in supine position for 28 fractions using tangential fields. 30 patients were aligned using AlignRT by aligning a breast surface region of interest (ROI) to the same area from a reference surface image extracted from planning CT. When the patient’s surface image deviated from the reference by more than 3mm on one or more translational and rotational directions, a new reference was acquired using AlignRT in-room cameras. The other 30 patients were aligned to the skin marks with room lasers. On-Board MV portal images of medial field were taken daily and matched to the DRRs. The magnitude and frequency of positioning errors were determined from measured translational shifts. Kolmogorov-Smirnov test was used to evaluate statistical differences of positional accuracy and precision between AlignRT and non-AlignRT patients. Results: The percentage of port images with no shift required was 46.5% and 27.0% in vertical, 49.8% and 25.8% in longitudinal, 47.6% and 28.5% in lateral for AlignRT and non-AlignRT patients, respectively. The percentage of port images requiring more than 3mm shifts was 18.1% and 35.1% in vertical, 28.6% and 50.8% in longitudinal, 11.3% and 24.2% in lateral for AlignRT and non-AlignRT patients, respectively. Kolmogorov-Smirnov test showed that there were significant differences between the frequency distributions of AlignRT and non-AlignRT in vertical, longitudinal, and lateral shifts. Conclusion: As confirmed by port images, AlignRT-assisted patient positioning can significantly reduce the frequency and magnitude of patient setup errors in breast irradiation compared to the use of lasers and skin marks.

  17. Role of Computer Aided Diagnosis (CAD in the detection of pulmonary nodules on 64 row multi detector computed tomography

    Directory of Open Access Journals (Sweden)

    K Prakashini

    2016-01-01

    Full Text Available Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2% and 202 (91.4% by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4% and nodules in hilar (100% and central (96.5% location when compared to RAD′s performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD′s performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  18. AutoCAD 2015 and AutoCAD LT 2015 essentials

    CERN Document Server

    Onstott, Scott

    2014-01-01

    Step-by-step instructions for the AutoCAD fundamentals AutoCAD 2015 Essentials contains 400 pages of full-color, comprehensive instruction on the world's top drafting and architecture software. This 2015 edition features architectural, manufacturing, and landscape architecture examples. And like previous editions, the detailed guide introduces core concepts using interactive tutorials and open-ended projects, which can be completed in any order, thanks to downloadable data sets (an especially useful feature for students and professionals studying for Autodesk AutoCAD certification). Unlike man

  19. AutoCAD 2012 and AutoCAD LT 2012 No Experience Required

    CERN Document Server

    Gladfelter, Donnie

    2011-01-01

    The perfect step-by-step introduction to Autodesk's powerful architectural design software With this essential guide, you'll learn how to plan, develop, document, and present a complete AutoCAD project by building a summer cabin from start to finish. You can follow each step sequentially or jump in at any point by downloading the drawing files from the book's companion web site. You'll also master all essential AutoCAD features, get a thorough grounding in the basics, learn the very latest industry standards and techniques, and quickly become productive with AutoCAD 2012.Features concise expla

  20. Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD).

    Science.gov (United States)

    Balleyguier, Corinne; Arfi-Rouche, Julia; Levy, Laurent; Toubiana, Patrick R; Cohen-Scali, Franck; Toledano, Alicia Y; Boyer, Bruno

    2017-12-01

    Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0

  1. Reconfiguring trade mark law

    DEFF Research Database (Denmark)

    Elsmore, Matthew James

    2013-01-01

    -border setting, with a particular focus on small business and consumers. The article's overall message is to call for a rethink of received wisdom suggesting that trade marks are effective trade-enabling devices. The case is made for reassessing how we think about European trade mark law.......First, this article argues that trade mark law should be approached in a supplementary way, called reconfiguration. Second, the article investigates such a reconfiguration of trade mark law by exploring the interplay of trade marks and service transactions in the Single Market, in the cross...

  2. Toward clinically usable CAD for lung cancer screening with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R. [David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, CA (United States)

    2014-11-15

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  3. Toward clinically usable CAD for lung cancer screening with computed tomography

    International Nuclear Information System (INIS)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R.

    2014-01-01

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  4. Displacement of cryomodule in CADS injector II

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Jiandong; Zhang, Bin; Wang, Fengfeng; Wan, Yuqin; Sun, Guozhen; Yao, Junjie; Zhang, Juihui; He, Yuan [Chinese Academy of Sciences, Lanzhou (China). Inst. of Modern Physics

    2017-06-15

    As Cryomodule can easily reduce higher power consumption and length of an accelerator and the accelerator can be operated more continuously. The Chinese academy of sciences institute of modern physics is developing an accelerator driven subcritical system (CADS) Injector II. Cryomodules are extremely complex systems, and their design optimization is strongly dependent on the accelerator application for which they are intended.

  5. A Case Study in CAD Design Automation

    Science.gov (United States)

    Lowe, Andrew G.; Hartman, Nathan W.

    2011-01-01

    Computer-aided design (CAD) software and other product life-cycle management (PLM) tools have become ubiquitous in industry during the past 20 years. Over this time they have continuously evolved, becoming programs with enormous capabilities, but the companies that use them have not evolved their design practices at the same rate. Due to the…

  6. A Knowledge Based Approach to VLSI CAD

    Science.gov (United States)

    1983-09-01

    Avail-and/or Dist ISpecial L| OI. SEICURITY CLASIIrCATION OP THIS IPA.lErllm S Daene." A KNOwLEDE BASED APPROACH TO VLSI CAD’ Louis L Steinberg and...major issues lies in building up and managing the knowledge base of oesign expertise. We expect that, as with many recent expert systems, in order to

  7. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin

    2017-01-01

    PURPOSE To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (Pcementation of the novel CAD/CAM restorative materials. PMID:29279763

  8. Theory and practice of Auto CAD, computer graphics

    International Nuclear Information System (INIS)

    Hwang, Si Won; Choe, Hong Yeong; Shin, Jae Yeon; Lee, Ryong Cheol

    1990-08-01

    This book describes theory and practice of Auto CAD, computer graphics, which deals with peripheral of computer, occurrence of digital line by DDA, BRM, theory of conversion, data base and display and shape modeling. This book gives descriptions of outline of CAD system, Auto CAD, basic function practice, simple figure practice, the third angle projection drawing a little complex single object, machine drawing I, function practice of improved Auto CAD, edit, set up layer, and 3D, and 3D display function.

  9. Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study.

    Science.gov (United States)

    Sonmez, Nesrin; Gultekin, Pinar; Turp, Volkan; Akgungor, Gokhan; Sen, Deniz; Mijiritsky, Eitan

    2018-01-08

    Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey's HSD, and Student's t tests (α = .05). Fractured specimens were evaluated using SEM. The highest Vickers microhardness value was found for VITA Mark II (p CAD was found to have the highest flexural strength (p CAD was also higher than other tested block materials (p CAD groups. It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics.

  10. [The CAD-S, an instrument for the assessment of adaptation to divorce - separation].

    Science.gov (United States)

    Yárnoz Yaben, Sagrario; Comino González, Priscila

    2010-02-01

    The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.

  11. A CAD (Classroom Assessment Design) of a Computer Programming Course

    Science.gov (United States)

    Hawi, Nazir S.

    2012-01-01

    This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified…

  12. Improving the radiologist-CAD interaction : designing for appropriate trust

    NARCIS (Netherlands)

    Jorritsma, W.; Cnossen, F.; van Ooijen, P. M. A.

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist-CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the

  13. Fra form-Z til AutoCad

    DEFF Research Database (Denmark)

    Jensen, Henrik

    2003-01-01

    Dette kursus er lavet for at forberede de studerende til deres tegnestuepraktik, og dets indhold er planlagt i samarbejde med tegnestuerne. I 2003 var form-Z Arkitektskolens grundlæggende CAD-program; men på tegnestuerne arbejde man med AutoCad. Kurset er opbygget over CAD Clasic skabelonen (se min...

  14. The review of CAD for simulation of microwave devices

    Directory of Open Access Journals (Sweden)

    Drach V.E.

    2017-01-01

    Full Text Available the article is devoted to a brief review of modern CAD for electromagnetic modeling of microwave devices. Five major CAD systems are described in the article: FEKO, μWave Wizard, Sonnet, AWR Microwave Office, HFSS. The main methods are given for each CAD system used for simulation of microwave structures and the main advantages that distinguish its use.

  15. Mark Tompkins Canaccord

    OpenAIRE

    Mark Tompkins Canaccord

    2018-01-01

    Mark Tompkins Canaccord is a senior technologist for ecosystem and water resources management in SEC SAID Oakland, California office. In his career which lasts over fifteen years Mark has worked on project involving lake restorations, clean water engineering, ecological engineering and management, hydrology, hydraulics, sediment transport and other projects for environmental planning all over the country. Mark Tompkins Canaccord tries to blend his skills of planning and engineering with s...

  16. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    International Nuclear Information System (INIS)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo; Pitocco, Dario; Di Stasio, Enrico; Trani, Carlo

    2016-01-01

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  17. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Radiological Sciences - Institute of Radiology, Rome (Italy); Pitocco, Dario [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Internal Medicine, Rome (Italy); Di Stasio, Enrico [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Clinical Biochemistry, Rome (Italy); Trani, Carlo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Cardiovascular Medicine - Institute of Cardiology, Rome (Italy)

    2016-03-15

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  18. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. 28th International Conference on CAD/CAM, Robotics and Factories of the Future

    CERN Document Server

    Syan, Chanan

    2016-01-01

    This volume is based on the proceedings of the 28th International Conference on CAD/CAM, Robotics and Factories of the Future. This book specially focuses on the positive changes made in the field of robotics, CAD/CAM and future outlook for emerging manufacturing units. Some of the important topics discussed in the conference are product development and sustainability, modeling and simulation, automation, robotics and handling systems, supply chain management and logistics, advanced manufacturing processes, human aspects in engineering activities, emerging scenarios in engineering education and training. The contents of this set of proceedings will prove useful to both researchers and practitioners.

  20. AutoCAD 2014 review for certification official certification preparation

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The AutoCAD® 2014 Review for Certification book is intended for users of AutoCAD® preparing to complete the AutoCAD 2014 Certified Professional exam. This book contains a collection of relevant instructional topics, practice exercises, and review questions from the Autodesk Official Training Guides (AOTG) from ASCENT - Center for Technical Knowledge pertaining specifically to the Certified Professional exam topics and objectives. This book is intended for experienced users of AutoCAD in preparation for certification. New users of AutoCAD should refer to the AOTG training guides from ASCENT, such as AutoCAD/AutoCAD LT 2014 Fundamentals, for more comprehensive instruction.

  1. Evaluation of the specificity of radionuclide myocardial imaging for detecting CAD

    International Nuclear Information System (INIS)

    Liu Xiujie

    1992-01-01

    In order to evaluate the specificity of radionuclide myocardial perfusion imaging for detecting coronary artery disease (CAD), 50 patients with normal coronary arteriography and radionuclide myocardial perfusion scintigraphy were analysed. The results from 201 T1 (20 cases) and 99m Tc-MIBI (30 cases) studies showed that out of 33 patients with no organic cardiovascular disease, 29 had normal myocardial imaging, and the specificity of radionuclide myocardial imaging for detecting CAD was 87.8%. 4 normal young women had false positive myocardial imaging. Out of 17 patients with cardiovascular disease and normal coronary arteriography, 15 patients had abnormal myocardial imaging. The final clinical diagnoses of these 15 patients were: 4 patients with hypertrophic cardiomyopathy, 3 with old myocardial infarction, 2 with myocarditis, 3 with small coronary vessel disease, 1 with congestive cardiomyopathy, and 2 with other cardiac disorder. The points of differentiation between CAD and other cardiovascular disease using radionuclide techniques were discussed

  2. A CAD model for energy efficient offshore structures for desalination and energy generation

    Directory of Open Access Journals (Sweden)

    R. Rahul Dev,

    2016-09-01

    Full Text Available This paper presents a ‘Computer Aided Design (CAD’ model for energy efficient design of offshore structures. In the CAD model preliminary dimensions and geometric details of an offshore structure (i.e. semi-submersible are optimized to achieve a favorable range of motion to reduce the energy consumed by the ‘Dynamic Position System (DPS’. The presented model allows the designer to select the configuration satisfying the user requirements and integration of Computer Aided Design (CAD and Computational Fluid Dynamics (CFD. The integration of CAD with CFD computes a hydrodynamically and energy efficient hull form. Our results show that the implementation of the present model results into an design that can serve the user specified requirements with less cost and energy consumption.

  3. Analysis on the workspace of palletizing robot based on AutoCAD

    Science.gov (United States)

    Li, Jin-quan; Zhang, Rui; Guan, Qi; Cui, Fang; Chen, Kuan

    2017-10-01

    In this paper, a four-degree-of-freedom articulated palletizing robot is used as the object of research. Based on the analysis of the overall configuration of the robot, the kinematic mathematical model is established by D-H method to figure out the workspace of the robot. In order to meet the needs of design and analysis, using AutoCAD secondary development technology and AutoLisp language to develop AutoCAD-based 2D and 3D workspace simulation interface program of palletizing robot. At last, using AutoCAD plugin, the influence of structural parameters on the shape and position of the working space is analyzed when the structure parameters of the robot are changed separately. This study laid the foundation for the design, control and planning of palletizing robots.

  4. Lujan Mark-4

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michael Jeffrey [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zavorka, Lukas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Koehler, Paul E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-13

    This is a review of Mark-IV target neutronics design. It involved the major redesign of the upper tier, offering harder neutron spectra for upper-tier FPs; a redesign of the high-resolution (HR) moderator; and a preservation of the rest of Mark-III features.

  5. Mark Stock | NREL

    Science.gov (United States)

    Stock Mark Stock Scientific Visualization Specialist Mark.Stock@nrel.gov | 303-275-4174 Dr. Stock , virtual reality, parallel computing, and manipulation of large spatial data sets. As an artist, he creates . Stock built the SUNLIGHT artwork that is installed on the Webb Building in downtown Denver. In addition

  6. CAD/CAM-assisted breast reconstruction

    International Nuclear Information System (INIS)

    Melchels, Ferry; Hutmacher, Dietmar Werner; Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten; Warne, David; Barry, Mark; Ong, Fook Rhu; Chong, Woon Shin

    2011-01-01

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  7. AutoCAD-To-GIFTS Translator Program

    Science.gov (United States)

    Jones, Andrew

    1989-01-01

    AutoCAD-to-GIFTS translator program, ACTOG, developed to facilitate quick generation of small finite-element models using CASA/GIFTS finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Geometric entities recognized by ACTOG include points, lines, arcs, solids, three-dimensional lines, and three-dimensional faces. From this information, ACTOG creates GIFTS SRC file, which then reads into GIFTS preprocessor BULKM or modified and reads into EDITM to create finite-element model. SRC file used as is or edited for any number of uses. Written in Microsoft Quick-Basic (Version 2.0).

  8. CAD for cutting head exchange of roadheader

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Z.; Wu, Z.; Qian, P. [China Coal Research Institute (China). Shanghai Branch

    1999-08-01

    Improving the cutting method according to the actual operating conditions is an effective way to raise production efficiency. A cutting head designed by means of computer and CAD software is characterized by short design cycle but high design quality. Taking the AM-50 road header as an example, this paper shows that it is feasible to design an interchangeable cutting head for the machine without interfering with the main technical parameters. 2 refs., 5 figs., 1 tab.

  9. KiCad challenges the big ones

    CERN Document Server

    Antonella Del Rosso

    2015-01-01

    Printed Circuit Boards (PCB) are the heart of any electronic device, including your toaster and your smartphone. Designing PCBs is the job of electronic engineers who, so far, have often had no option but to use proprietary tools to design complex circuits. Thanks to the efforts that CERN experts have put in to improve the free KiCad software, that situation is about to change.   KiCad's development started in 1992 as a way to design PCBs, the units that control how an electronic device works. Since 2013, experts in the Beams department have made important contributions to KiCad as part of the Open Hardware Initiative (OHI), which provides a framework to facilitate knowledge exchange across the electronic design community. “Our vision is to allow the hardware developers to share as easily as their software colleagues,” says Javier Serrano, head of the BE-CO-HT section and OHI initiator. “Software sources are easily shared online because they are text ...

  10. TEACHING CAD PROGRAMMING TO ARCHITECTURE STUDENTS

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Caffarena CELANI

    2008-11-01

    Full Text Available The objective of this paper is to discuss the relevance of including the discipline of computer programming in the architectural curriculum. To do so I start by explaining how computer programming has been applied in other educational contexts with pedagogical success, describing Seymour Papert's principles. After that, I summarize the historical development of CAD and provide three historical examples of educational applications of computer programming in architecture, followed by a contemporary case that I find of particular relevance. Next, I propose a methodology for teaching programming for architects that aims at improving the quality of designs by making their concepts more explicit. This methodology is based on my own experience teaching computer programming for architecture students at undergraduate and graduate levels at the State University of Campinas, Brazil. The paper ends with a discussion about the role of programming nowadays, when most CAD software are user-friendly and do not require any knowledge of programming for improving performance. I conclude that the introduction of programming in the CAD curriculum within a proper conceptual framework may transform the concept of architectural education. Key-words: Computer programming; computer-aided design; architectural education.

  11. Continuous Surface Rendering, Passing from CAD to Physical Representation

    Directory of Open Access Journals (Sweden)

    Mario Covarrubias

    2013-06-01

    Full Text Available This paper describes a desktop-mechatronic interface that has been conceived to support designers in the evaluation of aesthetic virtual shapes. This device allows a continuous and smooth free hand contact interaction on a real and developable plastic tape actuated by a servo-controlled mechanism. The objective in designing this device is to reproduce a virtual surface with a consistent physical rendering well adapted to designers' needs. The desktop-mechatronic interface consists in a servo-actuated plastic strip that has been devised and implemented using seven interpolation points. In fact, by using the MEC (Minimal Energy Curve Spline approach, a developable real surface is rendered taking into account the CAD geometry of the virtual shapes. In this paper, we describe the working principles of the interface by using both absolute and relative approaches to control the position on each single control point on the MEC spline. Then, we describe the methodology that has been implemented, passing from the CAD geometry, linked to VisualNastran in order to maintain the parametric properties of the virtual shape. Then, we present the co-simulation between VisualNastran and MATLAB/Simulink used for achieving this goal and controlling the system and finally, we present the results of the subsequent testing session specifically carried out to evaluate the accuracy and the effectiveness of the mechatronic device.

  12. Multifunctional facades - design optimisation with CAD; Multifunktionale Fassaden - Effektive Auslegung durch CAD-Einsatz

    Energy Technology Data Exchange (ETDEWEB)

    Viotto, M. [Institut fuer Solare Energieversorgungstechnik (ISET), Kassel (Germany). Abt. fuer Anlagen- und Messtechnik

    1998-02-01

    The energetically optimal design of PV facades requires the consideration of many technical conditions (different elevations/orientations of modules; shading possibility; high and different module temperatures). It also requires the interface with architecture, civil and electrical engineering. To support this planning process, the software program PV-CAD was developed which rapidly calculates energy yield under conditions of inhomogeneous irradiance, shading, thermal behaviour of modules and electrical layout. PV-CAD is compatible with other civil and electrical engineering CAD programs and incorporates extensive databases (weather data; modules and inverter types). (orig.) [Deutsch] Fuer optimalen Energieertrag sind zahlreiche technische Randbedingungen bei der Auslegung einer Photovoltaik (PV)-Fassade zu beruecksichtigen (unterschiedliche Ausrichtungen/Neigungen der Module; moegliche Teilabschattung; hoehere und unterschiedliche Betriebstemperaturen). Installation und Betrieb einer PV-Fassade erfordern die Abstimmung zwischen Architektur, Bauwesen und Elektrotechnik. Zur Unterstuetzung der Planer wurde das Programm PV-CAD entwickelt, das den Energieertrag unter Beruecksichtigung von inhomogener Einstrahlung und Abschattung, Temperaturverhalten der Fassadenmodule sowie unterschiedlichen elektrischen Anlagenkonzepten schnell ermittelt; es fuegt sich nahtlos in CAD-Arbeitsumgebungen ein. (orig.)

  13. Different Routes for Conifer- and Sinapaldehyde and Higher Saccharification upon Deficiency in the Dehydrogenase CAD1.

    Science.gov (United States)

    Van Acker, Rebecca; Déjardin, Annabelle; Desmet, Sandrien; Hoengenaert, Lennart; Vanholme, Ruben; Morreel, Kris; Laurans, Françoise; Kim, Hoon; Santoro, Nicholas; Foster, Cliff; Goeminne, Geert; Légée, Frédéric; Lapierre, Catherine; Pilate, Gilles; Ralph, John; Boerjan, Wout

    2017-11-01

    In the search for renewable energy sources, genetic engineering is a promising strategy to improve plant cell wall composition for biofuel and bioproducts generation. Lignin is a major factor determining saccharification efficiency and, therefore, is a prime target to engineer. Here, lignin content and composition were modified in poplar ( Populus tremula × Populus alba ) by specifically down-regulating CINNAMYL ALCOHOL DEHYDROGENASE1 ( CAD1 ) by a hairpin-RNA-mediated silencing approach, which resulted in only 5% residual CAD1 transcript abundance. These transgenic lines showed no biomass penalty despite a 10% reduction in Klason lignin content and severe shifts in lignin composition. Nuclear magnetic resonance spectroscopy and thioacidolysis revealed a strong increase (up to 20-fold) in sinapaldehyde incorporation into lignin, whereas coniferaldehyde was not increased markedly. Accordingly, ultra-high-performance liquid chromatography-mass spectrometry-based phenolic profiling revealed a more than 24,000-fold accumulation of a newly identified compound made from 8-8 coupling of two sinapaldehyde radicals. However, no additional cinnamaldehyde coupling products could be detected in the CAD1-deficient poplars. Instead, the transgenic lines accumulated a range of hydroxycinnamate-derived metabolites, of which the most prominent accumulation (over 8,500-fold) was observed for a compound that was identified by purification and nuclear magnetic resonance as syringyl lactic acid hexoside. Our data suggest that, upon down-regulation of CAD1 , coniferaldehyde is converted into ferulic acid and derivatives, whereas sinapaldehyde is either oxidatively coupled into S'(8-8)S' and lignin or converted to sinapic acid and derivatives. The most prominent sink of the increased flux to hydroxycinnamates is syringyl lactic acid hexoside. Furthermore, low-extent saccharification assays, under different pretreatment conditions, showed strongly increased glucose (up to +81%) and

  14. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  15. Mark 1 Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Mark I Test Facility is a state-of-the-art space environment simulation test chamber for full-scale space systems testing. A $1.5M dollar upgrade in fiscal year...

  16. Mark Raidpere portreefotod Kielis

    Index Scriptorium Estoniae

    1999-01-01

    Kieli Linnagaleriis avatud 2. Ars Baltica fototriennaalil 'Can You Hear Me?' esindab Eestit Mark Raidpere seeriaga 'Portreed 1998'. Näituse Eesti-poolne kuraator Anu Liivak, kataloogiteksti kirjutas Anders Härm. Tuntumaid osalejaid triennaalil Wolfgang Tillmans

  17. Marks of Metal Copenhell

    DEFF Research Database (Denmark)

    2015-01-01

    Planchebaseret udendørs udstilling på musikfestivalen Copenhell 18-20/6 2015. En mindre udgave af udstillingen Marks of Metal - Logodesign og visualitet i heavy metal. Udarbejdet i samarbejde med Mediemuseet.......Planchebaseret udendørs udstilling på musikfestivalen Copenhell 18-20/6 2015. En mindre udgave af udstillingen Marks of Metal - Logodesign og visualitet i heavy metal. Udarbejdet i samarbejde med Mediemuseet....

  18. COMPUTER HARDWARE MARKING

    CERN Multimedia

    Groupe de protection des biens

    2000-01-01

    As part of the campaign to protect CERN property and for insurance reasons, all computer hardware belonging to the Organization must be marked with the words 'PROPRIETE CERN'.IT Division has recently introduced a new marking system that is both economical and easy to use. From now on all desktop hardware (PCs, Macintoshes, printers) issued by IT Division with a value equal to or exceeding 500 CHF will be marked using this new system.For equipment that is already installed but not yet marked, including UNIX workstations and X terminals, IT Division's Desktop Support Service offers the following services free of charge:Equipment-marking wherever the Service is called out to perform other work (please submit all work requests to the IT Helpdesk on 78888 or helpdesk@cern.ch; for unavoidable operational reasons, the Desktop Support Service will only respond to marking requests when these coincide with requests for other work such as repairs, system upgrades, etc.);Training of personnel designated by Division Leade...

  19. Implications of unchanged detection criteria with CAD as second reader of mammograms

    International Nuclear Information System (INIS)

    Bornefalk, Hans

    2006-01-01

    In this paper we address the use of computer-aided detection (CAD) systems as second readers in mammography. The approach is based on Bayesian decision theory and its implication for the choice of optimal operating points. The choice of a certain operating point along an ROC curve corresponds to a particular tradeoff between false positives and missed cancers. By minimizing a total risk function given this tradeoff, we determine optimal decision thresholds for the radiologist and CAD system when CAD is used as a second reader. We show that under very general circumstances, the performance of the sequential system is improved if the decision threshold of the latent human decision variable is increased compared to what it would have been in the absence of the CAD system. This means that an initial stricter decision criterion should be applied by the radiologist when CAD is used as a second reader than otherwise. First and foremost, the results in this paper should be interpreted qualitatively, but an attempt is made at quantifying the effect by tuning the model to a prospective study evaluating the use of CAD as a second reader. By making some necessary and plausible assumptions, we are able to estimate the effect of the resulting suboptimal operating point. In this study of 12 860 women, we estimate that a 15% reduction in callbacks for masses could have been achieved with only about a 1.5% relative decrease in sensitivity compared to that without using a stricter initial criterion by the radiologist. For microcalcifications the corresponding values are 7% and 0.2%

  20. Laser marking method and device

    International Nuclear Information System (INIS)

    Okazaki, Yuki; Aoki, Nobutada; Mukai, Narihiko; Sano, Yuji; Yamamoto, Seiji.

    1997-01-01

    An object is disposed in laser beam permeating liquid or gaseous medium. Laser beams such as CW laser or pulse laser oscillated from a laser device are emitted to the object to apply laser markings with less degradation of identification and excellent corrosion resistance on the surface of the object simply and easily. Upon applying the laser markings, a liquid or gas as a laser beam permeating medium is blown onto the surface of the object, or the liquid or gas in the vicinity of the object is sucked, the laser beam-irradiated portion on the surface can be cooled positively. Accordingly, the laser marking can be formed on the surface of the object with less heat affection to the object. In addition, if the content of a nitrogen gas in the laser beam permeating liquid medium is reduced by degassing to lower than a predetermined value, or the laser beam permeating gaseous medium is formed by an inert gas, a laser marking having high corrosion resistance and reliability can be formed on the surface of the objective member. (N.H.)

  1. An analysis of hospital brand mark clusters.

    Science.gov (United States)

    Vollmers, Stacy M; Miller, Darryl W; Kilic, Ozcan

    2010-07-01

    This study analyzed brand mark clusters (i.e., various types of brand marks displayed in combination) used by hospitals in the United States. The brand marks were assessed against several normative criteria for creating brand marks that are memorable and that elicit positive affect. Overall, results show a reasonably high level of adherence to many of these normative criteria. Many of the clusters exhibited pictorial elements that reflected benefits and that were conceptually consistent with the verbal content of the cluster. Also, many clusters featured icons that were balanced and moderately complex. However, only a few contained interactive imagery or taglines communicating benefits.

  2. Evaluation of effectiveness of a computer system (CAD) in the identification of lung nodules with low-dose MSCT: scanning technique and preliminary results

    International Nuclear Information System (INIS)

    Fraioli, Francesco; Catalano, Carlo; Almberger, Maria; Bertoletti, Linda; Cantisani, Vito; Danti, Massimiliano; Pediconi, Federica; Passariello, Roberto

    2005-01-01

    Purpose: Evaluation of the effectiveness of a computer-aided diagnosis (CAD) in the identification of pulmonary nodules. Materials and methods: Two observers (A1, A2) with different levels of experience independently evaluated 20 chest MSCT studies with and without the aid of a CAD system (LungCheck, R2 Technology, Inc.). The study parameters were as follows: 140 kVs, 40 mAs, collimation 4x1 mm, slice thickness 1.25 mm, reconstruction interval 1.0 mm. The observers analysed the images with and without CAD and evaluated: 1) nodule size (longer axis); 2) number and location of nodules; 3) reading time for each observer. The gold standard was represented by the evaluation of both readers in consensus with the aid of the CAD system. Results: Without CAD support the two readers identified 77 (A1) and 79 (A2) nodules and with CAD 81 (A1) and 82 (A2) nodules. Working in consensus the two observers identified 81 nodules without the aid of CAD and 84 nodules with the aid of CAD. Total number of nodules identified by CAD was 104, 25 of which were false positive and 5 false negative. The average reading time with the aid of CAD decreased by as much as 40% for both the observers. Conclusions: The preliminary results of our study suggest that the CAD technique is an accurate automatic support tool in the identification of pulmonary nodules. It reduces reading time and automatically supplies the size, volume, density and number of nodules, thus being useful both in screening programmes and in the follow-up of cancer patients, in whom comparison of the images is particularly difficult [it

  3. Molecular aspects of zygotic embryogenesis in sunflower (Helianthus annuus L.): correlation of positive histone marks with HaWUS expression and putative link HaWUS/HaL1L.

    Science.gov (United States)

    Salvini, Mariangela; Fambrini, Marco; Giorgetti, Lucia; Pugliesi, Claudio

    2016-01-01

    The link HaWUS/ HaL1L , the opposite transcriptional behavior, and the decrease/increase in positive histone marks bond to both genes suggest an inhibitory effect of WUS on HaL1L in sunflower zygotic embryos. In Arabidopsis, a group of transcription factors implicated in the earliest events of embryogenesis is the WUSCHEL-RELATED HOMEOBOX (WOX) protein family including WUSCHEL (WUS) and other 14 WOX protein, some of which contain a conserved WUS-box domain in addition to the homeodomain. WUS transcripts appear very early in embryogenesis, at the 16-cell embryo stage, but gradually become restricted to the center of the developing shoot apical meristem (SAM) primordium and continues to be expressed in cells of the niche/organizing center of SAM and floral meristems to maintain stem cell population. Moreover, WUS has decisive roles in the embryonic program presumably promoting the vegetative-to-embryonic transition and/or maintaining the identity of the embryonic stem cells. However, data on the direct interaction between WUS and key genes for seed development (as LEC1 and L1L) are not collected. The novelty of this report consists in the characterization of Helianthus annuus WUS (HaWUS) gene and in its analysis regarding the pattern of the methylated lysine 4 (K4) of the Histone H3 and of the acetylated histone H3 during the zygotic embryo development. Also, a parallel investigation was performed for HaL1L gene since two copies of the WUS-binding site (WUSATA), previously identified on HaL1L nucleotide sequence, were able to be bound by the HaWUS recombinant protein suggesting a not described effect of HaWUS on HaL1L transcription.

  4. Computer-aided detection (CAD) of lung nodules and small tumours on chest radiographs

    International Nuclear Information System (INIS)

    De Boo, D.W.; Prokop, M.; Uffmann, M.; Ginneken, B. van; Schaefer-Prokop, C.M.

    2009-01-01

    Detection of focal pulmonary lesions is limited by quantum and anatomic noise and highly influenced by variable perception capacity of the reader. Multiple studies have proven that lesions - missed at time of primary interpretation - were visible on the chest radiographs in retrospect. Computer-aided diagnosis (CAD) schemes do not alter the anatomic noise but aim at decreasing the intrinsic limitations and variations of human perception by alerting the reader to suspicious areas in a chest radiograph when used as a 'second reader'. Multiple studies have shown that the detection performance can be improved using CAD especially for less experienced readers at a variable amount of decreased specificity. There seem to be a substantial learning process for both, experienced and inexperienced readers, to be able to optimally differentiate between false positive and true positive lesions and to build up sufficient trust in the capabilities of these systems to be able to use them at their full advantage. Studies so far focussed on stand-alone performance of the CAD schemes to reveal the magnitude of potential impact or on retrospective evaluation of CAD as a second reader for selected study groups. Further research is needed to assess the performance of these systems in clinical routine and to determine the trade-off between performance increase in terms of increased sensitivity and decreased inter-reader variability and loss of specificity and secondary indicated follow-up examinations for further diagnostic workup.

  5. Importing CAD models into MONK and MCBEND

    International Nuclear Information System (INIS)

    Searson, K.; Fleurot, F.; Cooper, A. J.; Cowan, P.

    2009-01-01

    The direct use of Computer Aided Design (CAD) models in criticality and shielding codes has been a long standing goal for Sellafield Ltd. Such functionality could offer several advantages over the traditional method of text based modelling systems. Analysts would be able to take advantage of the advanced Graphical User Interface based modelling features provided by solid modelers, potentially reducing the costs associated with creating models in a format suitable for the analyst's criticality and shielding code. A prototype system has been developed that allows CAD models created in Autodesk Inventor or Solidworks to be used in criticality and shielding calculations. The system is based on the ANSI Initial Graphics Exchange Specification 5.3 standard and models are exported from the CAD software in Trimmed NURBS format. The format retains much more of the model's geometrical information than a format based on solid meshing techniques and avoids many of the associated problems such as large memory costs, surface approximations and void spaces. The time consuming and complex meshing process is also avoided. Runtime intersection calculations are performed using either a Bezier clipping process for NURBS based surface definitions, or by transforming the coordinate system through which the ray tracks for Surface of Revolution calculations. NURBS surfaces are therefore converted to Bezier form as the model is imported. In addition, the SR generatrix is, in general, converted to a 'strip tree' representation, allowing the SR intersection calculations to be performed with arbitrary generatrix shapes. Details of recent improvements to the Bezier clipping process are provided. Reduction in runtime of SR based Solidworks models over equivalent NURBS based Autodesk Inventor models is also demonstrated. (authors)

  6. Edge strength of CAD/CAM materials.

    Science.gov (United States)

    Pfeilschifter, Maria; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-05-16

    To investigate the edge force of CAD/CAM materials as a function of (a) material, (b) thickness, and (c) distance from the margin. Materials intended for processing with CAD/CAM were investigated: eight resin composites, one resin-infiltrated ceramic, and a clinically proven lithiumdisilicate ceramic (reference). To measure edge force (that is, load to failure/crack), plates (d = 1 mm) were fixed and loaded with a Vickers diamond indenter (1 mm/min, Zwick 1446) at a distance of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm from the edge. Edge force was defined as a loading force at a distance of 0.5 mm. The type of failure was determined. To investigate the influence of the thickness, all data were determined on 1-mm and 2-mm plates. To test the influence of bonding and an underlying dentin, individual 1-mm plates were bonded to a 1-mm-thick dentin-like (concerning modulus of elasticity) resin composite. For the 1-mm plates, edge force varied between 64.4 ± 24.2 N (Shofu Block HC) and 183.2 ± 63.3 N (ceramic reference), with significant (p ≤ 0.001) differences between the materials. For the 2-mm plates, values between 129.2 ± 32.5 N (Lava Ultimate) and 230.3 ± 67.5 N (Cerasmart) were found. Statistical comparison revealed no significant differences (p > 0.109) between the materials. Brilliant Crios (p = 0.023), Enamic (p = 0.000), Shofu Blocks HC (p = 0.009), and Grandio Bloc (p = 0.002) showed significantly different edge force between the 1-mm- and 2-mm-thick plates. The failure pattern was either cracking, (severe) chipping, or fracture. Material, material thickness, and distance from the edge impact the edge force of CAD/CAM materials. CAD/CAM materials should be carefully selected on the basis of their individual edge force and performance during milling. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. DESIGNING AN EFFECTIVE INTERSECTION USING CAD ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    CRISAN George-Horea

    2017-05-01

    Full Text Available Ensuring the safety and streamline in road traffic are very important aims, with regard to the nowadays people mobility level. Road infrastructure is an essential element that can meet these requirements. Thus, it is proposed to develop an effective model of intersection by using CAD software tools. This type of intersection can be successfully used on almost any category of roads, increasing road traffic safety, reducing passing times through the intersection and in the same time, reducing conflict points and increase the intersection capacity.

  8. Manipulating cinnamyl alcohol dehydrogenase (CAD) expression in flax affects fibre composition and properties

    Science.gov (United States)

    2014-01-01

    Background In recent decades cultivation of flax and its application have dramatically decreased. One of the reasons for this is unpredictable quality and properties of flax fibre, because they depend on environmental factors, retting duration and growing conditions. These factors have contribution to the fibre composition, which consists of cellulose, hemicelluloses, lignin and pectin. By far, it is largely established that in flax, lignin reduces an accessibility of enzymes either to pectin, hemicelluloses or cellulose (during retting or in biofuel synthesis and paper production). Therefore, in this study we evaluated composition and properties of flax fibre from plants with silenced CAD (cinnamyl alcohol dehydrogenase) gene, which is key in the lignin biosynthesis. There is evidence that CAD is a useful tool to improve lignin digestibility and/or to lower the lignin levels in plants. Results Two studied lines responded differentially to the introduced modification due to the efficiency of the CAD silencing. Phylogenetic analysis revealed that flax CAD belongs to the “bona-fide” CAD family. CAD down-regulation had an effect in the reduced lignin amount in the flax fibre cell wall and as FT-IR results suggests, disturbed lignin composition and structure. Moreover introduced modification activated a compensatory mechanism which was manifested in the accumulation of cellulose and/or pectin. These changes had putative correlation with observed improved fiber’s tensile strength. Moreover, CAD down-regulation did not disturb at all or has only slight effect on flax plants’ development in vivo, however, the resistance against flax major pathogen Fusarium oxysporum decreased slightly. The modification positively affected fibre possessing; it resulted in more uniform retting. Conclusion The major finding of our paper is that the modification targeted directly to block lignin synthesis caused not only reduced lignin level in fibre, but also affected amount and

  9. Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo

    2017-08-15

    Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Augmented marked graphs

    CERN Document Server

    Cheung, King Sing

    2014-01-01

    Petri nets are a formal and theoretically rich model for the modelling and analysis of systems. A subclass of Petri nets, augmented marked graphs possess a structure that is especially desirable for the modelling and analysis of systems with concurrent processes and shared resources.This monograph consists of three parts: Part I provides the conceptual background for readers who have no prior knowledge on Petri nets; Part II elaborates the theory of augmented marked graphs; finally, Part III discusses the application to system integration. The book is suitable as a first self-contained volume

  11. Mammogram CAD, hybrid registration and iconic analysis

    Science.gov (United States)

    Boucher, A.; Cloppet, F.; Vincent, N.

    2013-03-01

    This paper aims to develop a computer aided diagnosis (CAD) based on a two-step methodology to register and analyze pairs of temporal mammograms. The concept of "medical file", including all the previous medical information on a patient, enables joint analysis of different acquisitions taken at different times, and the detection of significant modifications. The developed registration method aims to superimpose at best the different anatomical structures of the breast. The registration is designed in order to get rid of deformation undergone by the acquisition process while preserving those due to breast changes indicative of malignancy. In order to reach this goal, a referent image is computed from control points based on anatomical features that are extracted automatically. Then the second image of the couple is realigned on the referent image, using a coarse-to-fine approach according to expert knowledge that allows both rigid and non-rigid transforms. The joint analysis detects the evolution between two images representing the same scene. In order to achieve this, it is important to know the registration error limits in order to adapt the observation scale. The approach used in this paper is based on an image sparse representation. Decomposed in regular patterns, the images are analyzed under a new angle. The evolution detection problem has many practical applications, especially in medical images. The CAD is evaluated using recall and precision of differences in mammograms.

  12. Identification markings for gemstones

    International Nuclear Information System (INIS)

    Dreschhoff, G.A.M.; Zeller, E.J.

    1980-01-01

    A method is described of providing permanent identification markings to gemstones such as diamond crystals by irradiating the cooled gemstone with protons in the desired pattern. The proton bombardment results in a reaction limited to a defined plane and converting the bombarded area of the plane into a different crystal lattice from that of the preirradiated stone. (author)

  13. Applying a CAD-generated imaging marker to assess short-term breast cancer risk

    Science.gov (United States)

    Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin

    2018-02-01

    Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (pbreast cancer risk.

  14. DEVELOPMENT OF EDIFICATION’S PROJECT – A COMPARATIVE STUDY ODF CAD AND BIM PLATAFORMS

    Directory of Open Access Journals (Sweden)

    Lúcio Campos Neto

    2017-12-01

    Full Text Available Several technologies are used to simplify the process and creation of design, highlighting the CAD and the BIM. At CAD, the elements are represented by lines, while at BIM the objects are ruled by attributes and parametric information, allowing the virtual simulation of the edification. Although the BIM is a novelty in design’s process, the largest part of professionals still makes use of CAD. In front of these facts, the objective of this research is to evaluate the difference of using each plataform. The research was guided by the hypothesis that BIM concept presents pros and cons to the process of projects development once it is compared to CAD software. For this, one same project has been developed in both plataforms in order to demonstrate which plataform has the best characteristics at the development process and final result, indicating its difficulties, facilies, esthetics, reading, handling, interface and tools. With the proposed methodology execution, it has been noticed that each plataform possesses positive and negative characteristics, influencing each professional’s choice for a software. This choice will vary according to the situation, to what plataform the professional gets better used to and according to the investment potential.

  15. A visual LISP program for voxelizing AutoCAD solid models

    Science.gov (United States)

    Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz

    2015-01-01

    AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.

  16. 3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION.

    Science.gov (United States)

    Petersen, Richard; Liu, Perng-Ru

    2016-05-01

    Three-dimensional (3D)-woven noncrimp fiber-reinforced composite (FRC) was tested for mechanical properties in the two principal directions of the main XY plane and compared to different Computer-Aided-Design/Computer-Aided-Machining (CAD/CAM) Dental Materials. The Dental Materials included ceramic with Vitablock Mark II®, ProCAD®, InCeram® Spinel, InCeram® Alumina and InCeram® Zirconia in addition to a resin-based 3M Corp. Paradigm® particulate-filled composite. Alternate material controls included Coors 300 Alumina Ceramic and a tungsten carbide 22% cobalt cermet. The 3D-woven FRC was vacuum assisted resin transfer molding processed as a one-depth-thickness ~19-mm preform with a vinyl-ester resin and cut into blocks similar to the commercial CAD/CAM Dental Materials. Mechanical test samples prepared for a flexural three-point span length of 10.0 mm were sectioned for minimum-depth cuts to compare machinability and fracture resistance between groups. 3D-woven FRC improved mechanical properties with significant statistical differences over all CAD/CAM Dental Materials and Coors Alumina Ceramic for flexural strength (p<0.001), resilience (p<0.05), work of fracture (p<0.001), strain energy release (p<0.05), critical stress intensity factor (p<0.001) and strain (p<0.001).

  17. The CAD concept for stellarator-type magnetic systems

    International Nuclear Information System (INIS)

    Vorobyova, V.P.; Martynov, S.A.; Khazhmuradov, M.A.

    2002-01-01

    The paper describes the computer-aided design (CAD) concept for stellarator-type magnetic systems. Consideration is given to the main peculiarities, principles, and dialog organization and design stages of the CAD. The practical realization of the concept is illustrated by specific examples

  18. Teach CAD and Measuring Skills through Reverse Engineering

    Science.gov (United States)

    Board, Keith

    2012-01-01

    This article describes a reverse engineering activity that gives students hands-on, minds-on experience with measuring tools, machine parts, and CAD. The author developed this activity to give students an abundance of practical experience with measuring tools. Equally important, it provides a good interface between the virtual world of CAD 3D…

  19. An Instructional Method for the AutoCAD Modeling Environment.

    Science.gov (United States)

    Mohler, James L.

    1997-01-01

    Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)

  20. Control console conceptual design for sheet type fuels of Triga Mark-II reactor

    International Nuclear Information System (INIS)

    Eko Priyono; Kurnia Wibowo; Anang Susanto

    2016-01-01

    The control console conceptual design for sheet type fuel of TRIGA Mark-II reactor has been made. The control console conceptual design was made with refer study result of instrument and control system which is used in BATAN'S reactor i.e TRIGA-2000 Bandung, TRIGA Yogyakarta and MPR-30 Serpong. The control console conceptual design was made by using AutoCad software. The control console conceptual design reactor for sheet type fuel of TRIGA Mark-II reactor consist of 5 segments that is 3 segments for placing the computer monitors, 1 segment for placing bargraph displays and recorders and 1 segment for placing panel meters. There are the door on front and back position at each segment for enter and out devices in the console. The control console conceptual design is also equipped by the table along in front of console for placing reactor panel control and for writing, 3 drawers for 3 keyboards. The dimension of console will refer control room size and the components will be placed on console which will be detailed in detail design if this conceptual design has been approved. (author)

  1. Interview with Mark Watson

    Directory of Open Access Journals (Sweden)

    Katy Shaw

    2016-04-01

    Full Text Available Mark Watson is a British comedian and novelist. His five novels to date – 'Bullet Points' (2004, 'A Light-Hearted Look At Murder' (2007, 'Eleven' (2010, 'The Knot' (2012 and 'Hotel Alpha' (2014 – explore human relationships and communities in contemporary society. His latest novel Hotel Alpha tells the story of an extraordinary hotel in London and two mysterious disappearances that raise questions no one seems willing to answer. External to the novel, readers can also discover more about the hotel and its inhabitants in one hundred extra stories that expand the world of the novel and can be found at http://www.hotelalphastories.com. In conversation here with Dr Katy Shaw, Mark offers some reflections on his writing process, the field of contemporary literature, and the vitality of the novel form in the twenty-first century.

  2. Technology CAD for germanium CMOS circuit

    Energy Technology Data Exchange (ETDEWEB)

    Saha, A.R. [Department of Electronics and ECE, IIT Kharagpur, Kharagpur-721302 (India)]. E-mail: ars.iitkgp@gmail.com; Maiti, C.K. [Department of Electronics and ECE, IIT Kharagpur, Kharagpur-721302 (India)

    2006-12-15

    Process simulation for germanium MOSFETs (Ge-MOSFETs) has been performed in 2D SILVACO virtual wafer fabrication (VWF) suite towards the technology CAD for Ge-CMOS process development. Material parameters and mobility models for Germanium were incorporated in simulation via C-interpreter function. We also report on the device design issues along with the DC and RF characterization of the bulk Ge-MOSFETs, AC parameter extraction and circuit simulation of Ge-CMOS. Simulation results are compared with bulk-Si devices. Simulations predict a cut-off frequency, f {sub T} of about 175 GHz for Ge-MOSFETs compared to 70 GHz for a similar gate-length Si MOSFET. For a single stage Ge-CMOS inverter circuit, a GATE delay of 0.6 ns is predicted.

  3. Technology CAD for germanium CMOS circuit

    International Nuclear Information System (INIS)

    Saha, A.R.; Maiti, C.K.

    2006-01-01

    Process simulation for germanium MOSFETs (Ge-MOSFETs) has been performed in 2D SILVACO virtual wafer fabrication (VWF) suite towards the technology CAD for Ge-CMOS process development. Material parameters and mobility models for Germanium were incorporated in simulation via C-interpreter function. We also report on the device design issues along with the DC and RF characterization of the bulk Ge-MOSFETs, AC parameter extraction and circuit simulation of Ge-CMOS. Simulation results are compared with bulk-Si devices. Simulations predict a cut-off frequency, f T of about 175 GHz for Ge-MOSFETs compared to 70 GHz for a similar gate-length Si MOSFET. For a single stage Ge-CMOS inverter circuit, a GATE delay of 0.6 ns is predicted

  4. CAD-CAM printed circuit board design

    Science.gov (United States)

    Agy, W. E.

    A step-by-step procedure for a printed circuit design achieved by CAD is presented. The operator at the interactive CRT station moves a stylus across a graphics tablet and intersperses commands which result in computer-generated pictorial forms on the screen that were drawn on the pad. Standard symbols are used for commands allowing, for instance, connections to be made of specific types in certain locations, which can be automatically edited from a materials list. An entire network of drawn lines can be referenced by a signal name for recall, and a finished circuit schematic can be checked for designs rules compliance, including fault reporting in terms of designator/pin number. A map may be present delineating the boundaries of the circuitry area, and previously completed circuitry segments can be recalled for piece-by-piece assembly of the circuit board.

  5. Myocardial perfusion scintigraphy - possibilities of diagnosing CAD

    International Nuclear Information System (INIS)

    Tsonevska, A.

    1998-01-01

    A reviewing the diagnostic methods used in the intricate process of evaluating CAD patients in a attempt to establish the role played by radionuclide methods in the diagnostic strategy is done. The perfusion cardiotropic radiopharmaceuticals used and the various methods of evaluating myocardial are discussed. Although 210 Tl-chloride is the most widely used myocardial perfusion agent, recently 99m Tc-MIBI is proposed as an alternative because of its advantages. Myocardial perfusion assessment is done by various techniques depending on the specific aim, each of them having its proper advantages and shortcomings. The inference is reached that regardless of the routine practical implementation of myocardial perfusion scintigraphy and comprehensive studies along this line in course, there are problems still not well enough clarified awaiting solution

  6. The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM).

    Science.gov (United States)

    Goryainova, Kristina E; Morokov, Egor S; Retinskaja, Marina V; Rusanov, Fedor S; Apresyan, Samvel V; Lebedenko, Igor Yu

    2018-01-01

    The aim of the present work was to compare the elastic properties and internal structure of 4 different CAD/CAM chairside materials, by the method of Scanning Impulse Acoustic Microscopy (SIAM). Four chairside CAD/CAM materials with different structures from hybrid ceramic (VITA Enamic, VITA Zahnfabrik), feldspatic ceramic (VITABlocs Mark II, VITA Zahnfabrik), leucite glass-ceramic (IPS Empress CAD, Ivoclar Vivadent) and PMMA (Telio CAD, Ivoclar Vivadent) were examined by Scanning Impulse Acoustic Microscope (SIAM). The results of micromorphological research of CAD/CAM chairside materials using SIAM method showed differences between the internal structures of these materials. The internal structure of feldspatic and glass-ceramic samples revealed the presence of pores with different sizes, from 10 to 100 microns; the structure of polymer materials rendered some isolated defects, while in the structure of hybrid material, defects were not found. Based on the results obtained from the present study, in cases of chairside production of dental crowns, it would be advisable to give preference to the blocks of hybrid ceramics. Such ceramics devoid of quite large porosity, glazing for CAD/CAM crowns made from leucite glass-ceramic and feldspatic ceramic may be an option. For these purposes, commercially available special muffle furnace for clinical and laboratory individualization and glazing of ceramic prostheses were provided. Further studies are needed to confirm the evidence emerging from the present research.

  7. The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)

    Science.gov (United States)

    Goryainova, Kristina E.; Morokov, Egor S.; Retinskaja, Marina V.; Rusanov, Fedor S.; Apresyan, Samvel V.; Lebedenko, Igor Yu.

    2018-01-01

    Aim: The aim of the present work was to compare the elastic properties and internal structure of 4 different CAD/CAM chairside materials, by the method of Scanning Impulse Acoustic Microscopy (SIAM). Methods: Four chairside CAD/CAM materials with different structures from hybrid ceramic (VITA Enamic, VITA Zahnfabrik), feldspatic ceramic (VITABlocs Mark II, VITA Zahnfabrik), leucite glass-ceramic (IPS Empress CAD, Ivoclar Vivadent) and PMMA (Telio CAD, Ivoclar Vivadent) were examined by Scanning Impulse Acoustic Microscope (SIAM). Results: The results of micromorphological research of CAD/CAM chairside materials using SIAM method showed differences between the internal structures of these materials. The internal structure of feldspatic and glass-ceramic samples revealed the presence of pores with different sizes, from 10 to 100 microns; the structure of polymer materials rendered some isolated defects, while in the structure of hybrid material, defects were not found. Conclusion: Based on the results obtained from the present study, in cases of chairside production of dental crowns, it would be advisable to give preference to the blocks of hybrid ceramics. Such ceramics devoid of quite large porosity, glazing for CAD/CAM crowns made from leucite glass-ceramic and feldspatic ceramic may be an option. For these purposes, commercially available special muffle furnace for clinical and laboratory individualization and glazing of ceramic prostheses were provided. Further studies are needed to confirm the evidence emerging from the present research. PMID:29492178

  8. Isotopic marking and tracers

    International Nuclear Information System (INIS)

    Morel, F.

    1997-01-01

    The use of radioactive isotopes as tracers in biology has been developed thanks to the economic generation of the required isotopes in accelerators and nuclear reactors, and to the multiple applications of tracers in the life domain; the most usual isotopes employed in biology are carbon, hydrogen, phosphorus and sulfur isotopes, because these elements are present in most of organic molecules. Most of the life science knowledge appears to be dependent to the extensive use of nuclear tools and radioactive tracers; the example of the utilization of radioactive phosphorus marked ATP to study the multiple reactions with proteins, nucleic acids, etc., is given

  9. Ceremony marking Einstein Year

    CERN Multimedia

    2005-01-01

    Sunday 13th November at 10:00amat Geneva's St. Peter's Cathedral To mark Einstein Year and the importance of the intercultural dialogue of which it forms a part, a religious service will take place on Sunday 13 November at 10 a.m. in St. Peter's Cathedral, to which CERN members and colleagues are warmly welcomed. Pastor Henry Babel, senior minister at the Cathedral, will speak on the theme: 'God in Einstein's Universe'. Diether Blechschmidt will convey a message on behalf of the scientific community.

  10. Minimal Marking: A Success Story

    Science.gov (United States)

    McNeilly, Anne

    2014-01-01

    The minimal-marking project conducted in Ryerson's School of Journalism throughout 2012 and early 2013 resulted in significantly higher grammar scores in two first-year classes of minimally marked university students when compared to two traditionally marked classes. The "minimal-marking" concept (Haswell, 1983), which requires…

  11. CAD-centric Computation Management System for a Virtual TBM

    Energy Technology Data Exchange (ETDEWEB)

    Ramakanth Munipalli; K.Y. Szema; P.Y. Huang; C.M. Rowell; A.Ying; M. Abdou

    2011-05-03

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  12. CAD: How it works, how to use it, performance

    International Nuclear Information System (INIS)

    Regge, Daniele; Halligan, Steve

    2013-01-01

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence

  13. CAD: How it works, how to use it, performance

    Energy Technology Data Exchange (ETDEWEB)

    Regge, Daniele, E-mail: daniele.regge@ircc.it [Institute for Cancer Research and Treatment, Candiolo-Torino (Italy); Halligan, Steve, E-mail: s.halligan@ucl.ac.uk [University College Hospital London, London (United Kingdom)

    2013-08-15

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence.

  14. Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

    International Nuclear Information System (INIS)

    Choi, Eun Jung; Jin, Gong Yong; Han, Young Min; Lee, Young Sun; Kweon, Keun Sang

    2008-01-01

    We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within ± 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. The CAD system was a useful tool for diagnosing malignant SPNs

  15. Engineering drawing from first principles using AutoCAD

    CERN Document Server

    Maguire, Dennis E

    1998-01-01

    Engineering Drawing From First Principles is a guide to good draughting for students of engineering who need to learn how to produce technically accurate and detailed designs to British and International Standards. Written by Dennis Maguire, an experienced author and City and Guilds chief examiner, this text is designed for use on Further Education and University courses where a basic understanding of draughtsmanship and CAD is necessary. Although not written as an AutoCAD tutor, the book will be a useful introduction to good CAD practice.Part of the Revision and Self-Assessmen

  16. Complete PCB design using OrCAD capture and layout

    CERN Document Server

    Mitzner, Kraig

    2011-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The book is written for both students and practicing engineers who need a quick tutorial on how to use the software and who need in-depth knowledge of the capabilities and limitations of the software package. There are two goals the book aims to reach:The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Layout. Capture is used to build the schematic diagram of the circuit, and Layout is used to design the circuit board so that

  17. A computer-aided detection (CAD) system with a 3D algorithm for small acute intracranial hemorrhage

    Science.gov (United States)

    Wang, Ximing; Fernandez, James; Deshpande, Ruchi; Lee, Joon K.; Chan, Tao; Liu, Brent

    2012-02-01

    Acute Intracranial hemorrhage (AIH) requires urgent diagnosis in the emergency setting to mitigate eventual sequelae. However, experienced radiologists may not always be available to make a timely diagnosis. This is especially true for small AIH, defined as lesion smaller than 10 mm in size. A computer-aided detection (CAD) system for the detection of small AIH would facilitate timely diagnosis. A previously developed 2D algorithm shows high false positive rates in the evaluation based on LAC/USC cases, due to the limitation of setting up correct coordinate system for the knowledge-based classification system. To achieve a higher sensitivity and specificity, a new 3D algorithm is developed. The algorithm utilizes a top-hat transformation and dynamic threshold map to detect small AIH lesions. Several key structures of brain are detected and are used to set up a 3D anatomical coordinate system. A rule-based classification of the lesion detected is applied based on the anatomical coordinate system. For convenient evaluation in clinical environment, the CAD module is integrated with a stand-alone system. The CAD is evaluated by small AIH cases and matched normal collected in LAC/USC. The result of 3D CAD and the previous 2D CAD has been compared.

  18. Colour parameters and shade correspondence of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Pecho, Oscar E; Ghinea, Razvan; Cardona, Juan C; Pérez, María M

    2015-06-01

    To evaluate colour differences between (1) CAD-CAM ceramic systems considering shades A1, A2 and A3 and the corresponding nominal shade of VC (Vita Classical shade guide) and (2) shades A1-A2, A2-A3 and A1, A2 and A3 within the same ceramic system. Samples of shades A1, A2 and A3 were fabricated (n=5) from CAD-CAM ceramic blocks (IPS e.max(®) CAD LT and HT, IPS Empress(®) CAD LT and HT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. Spectral reflectance and colour coordinates were measured using a spectroradiometer inside a viewing booth using the CIE D65 illuminant and the d/0° geometry. Spectral reflectance curves were compared using VAF coefficient and were statistically analyzed using Kruskal-Wallis and the Mann-Whitney U test (α=0.05). Colour coordinates were statistically analyzed using one-way ANOVA, Tukey's test with Bonferroni correction (α=0.001). All colour differences (ΔEab(*) and ΔE00) were analyzed through comparisons with the PT - perceptibility and AT - acceptability thresholds for dental ceramics. ΔE between ceramic systems and its corresponding shade ranged from 6.32 to 13.42 (ΔEab(*)) and 4.48 to 9.30 (ΔE00). ΔE between shades A1-A2, A2-A3 and A1, A2 and A3 ranged, respectively, 1.93-4.82, 1.22-5.59 and 3.63-8.84 (ΔEab(*)); 1.54-3.87, 1.03-3.90 and 2.95-6.51 (ΔE00). Considering the corresponding nominal shade from VC, none of the ceramic systems showed colour differences below the AT. In addition, some ceramic systems showed colour differences below AT (shades A1-A2 and A2-A3) and below PT (shades A2-A3). Careful adjustments should be made to the final shade of CAD-CAM ceramic restorations to reach a clinically acceptable shade match. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Dialectica Interpretation with Marked Counterexamples

    Directory of Open Access Journals (Sweden)

    Trifon Trifonov

    2011-01-01

    Full Text Available Goedel's functional "Dialectica" interpretation can be used to extract functional programs from non-constructive proofs in arithmetic by employing two sorts of higher-order witnessing terms: positive realisers and negative counterexamples. In the original interpretation decidability of atoms is required to compute the correct counterexample from a set of candidates. When combined with recursion, this choice needs to be made for every step in the extracted program, however, in some special cases the decision on negative witnesses can be calculated only once. We present a variant of the interpretation in which the time complexity of extracted programs can be improved by marking the chosen witness and thus avoiding recomputation. The achieved effect is similar to using an abortive control operator to interpret computational content of non-constructive principles.

  20. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations.

    Science.gov (United States)

    Quaas, Sebastian; Rudolph, Heike; Luthardt, Ralph G

    2007-12-01

    The basic prerequisite for the production of dental restorations by means of CAD/CAM technologies is the data acquisition (digitization). Currently, two methods are available, i.e. the extraoral digitization of master casts and the direct intraoral data acquisition. However, it seems to be beneficial to immediately digitize impressions directly at the dental office in order to combine the high precision of mechanical digitizing methods and to shorten the production process. The aim of this study was to investigate the measurement uncertainty (+/-2sigma) and the three-dimensional accuracy of the immediate tactile in-office digitization of dental impressions and of the mechanical digitizing of ceramic master dies using a high-precision touch-probe digitizer. The experimental set-up consisted of ceramic master dies representing tooth 13 and 36 as well as their identical virtual models (CAD models). Fifteen one-step putty-wash impressions were taken from each tooth. The impressions as well as the ceramic master dies were digitized applying a standardized procedure. The datasets were aligned to the corresponding CAD models; then, a computer-aided three-dimensional analysis was performed. The digitizing of the dental impressions showed a measurement uncertainty of 5.8, mean positive deviations between 27 and 28microm, and mean negative deviations between -21 and -31microm. The digitizing of the ceramic master dies showed a measurement uncertainty of 2.8, mean positive deviations between 7.7 and 9.1microm, and mean negative deviations between -8.5 and -8.8microm. Mechanical digitizers show a very low measurement uncertainty and a high precision. The immediate tactile in-office digitization of impressions cannot be recommended as adequate data acquisition method for CAD/CAM restorations. It is recommendable to digitize clinical sites extraorally, i.e. after taking an impression and fabricating a model cast thereof.

  1. Solid modeling and applications rapid prototyping, CAD and CAE theory

    CERN Document Server

    Um, Dugan

    2016-01-01

    The lessons in this fundamental text equip students with the theory of Computer Assisted Design (CAD), Computer Assisted Engineering (CAE), the essentials of Rapid Prototyping, as well as practical skills needed to apply this understanding in real world design and manufacturing settings. The book includes three main areas: CAD, CAE, and Rapid Prototyping, each enriched with numerous examples and exercises. In the CAD section, Professor Um outlines the basic concept of geometric modeling, Hermite and Bezier Spline curves theory, and 3-dimensional surface theories as well as rendering theory. The CAE section explores mesh generation theory, matrix notion for FEM, the stiffness method, and truss Equations. And in Rapid Prototyping, the author illustrates stereo lithographic theory and introduces popular modern RP technologies. Solid Modeling and Applications: Rapid Prototyping, CAD and CAE Theory is ideal for university students in various engineering disciplines as well as design engineers involved in product...

  2. Harmonizing interoperability - Emergent Serious Gaming in Playful Stochastic CAD Environments

    NARCIS (Netherlands)

    Kosmadoudi, Z.; Lim, T.; Ritchie, J.M.; Liu, Y.; Sung, R.; Hauge, J.B.; Garbaya, S.; Wendrich, Robert E.; Stanescu, I.A.; De Gloria, Alessandro

    2014-01-01

    Computer-Aided Design (CAD) applications often promote memorable experiences for the wrong reasons. Coupled with complex functionality and poor user experience the learning curve is often steep and overwhelming. Invoking design creativity remains limited to conveying established geometry. Gameplay

  3. Geometric data transfer between CAD systems: solid models

    DEFF Research Database (Denmark)

    Kroszynski, Uri; Palstroem, Bjarne; Trostmann, Erik

    1989-01-01

    The first phase of the ESPRIT project CAD*I resulted in a specification for the exchange of solid models as well as in some pilot implementations of processors based on this specification. The authors summarize the CAD*I approach, addressing the structure of neutral files for solids, entities......, and attributes supporting three kinds of representations: facilities for the transfer of parametric designs; referencing library components; and other general mechanisms. They also describe the current state of the specification and processor implementations and include an example of a CAD*I neutral file....... Results from cycle and intersystem solid model transfer tests are presented, showing the practicality of the CAD*I proposal. B-rep model transfer results are discussed in some detail. The relationship of this work to standardization efforts is outlined...

  4. Resin-composite blocks for dental CAD/CAM applications.

    Science.gov (United States)

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  5. CAD-CAE in Electrical Machines and Drives Teaching.

    Science.gov (United States)

    Belmans, R.; Geysen, W.

    1988-01-01

    Describes the use of computer-aided design (CAD) techniques in teaching the design of electrical motors. Approaches described include three technical viewpoints, such as electromagnetics, thermal, and mechanical aspects. Provides three diagrams, a table, and conclusions. (YP)

  6. Structured reporting platform improves CAD-RADS assessment.

    Science.gov (United States)

    Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; Jermendy, Ádám L; Károlyi, Mihály; Panajotu, Alexisz; Bagyura, Zsolt; Vecsey-Nagy, Milán; Cury, Ricardo C; Leipsic, Jonathon A; Merkely, Béla; Maurovich-Horvat, Pál

    2017-11-01

    Structured reporting in cardiac imaging is strongly encouraged to improve quality through consistency. The Coronary Artery Disease - Reporting and Data System (CAD-RADS) was recently introduced to facilitate interdisciplinary communication of coronary CT angiography (CTA) results. We aimed to assess the agreement between manual and automated CAD-RADS classification using a structured reporting platform. Five readers prospectively interpreted 500 coronary CT angiographies using a structured reporting platform that automatically calculates the CAD-RADS score based on stenosis and plaque parameters manually entered by the reader. In addition, all readers manually assessed CAD-RADS blinded to the automatically derived results, which was used as the reference standard. We evaluated factors influencing reader performance including CAD-RADS training, clinical load, time of the day and level of expertise. Total agreement between manual and automated classification was 80.2%. Agreement in stenosis categories was 86.7%, whereas the agreement in modifiers was 95.8% for "N", 96.8% for "S", 95.6% for "V" and 99.4% for "G". Agreement for V improved after CAD-RADS training (p = 0.047). Time of the day and clinical load did not influence reader performance (p > 0.05 both). Less experienced readers had a higher total agreement as compared to more experienced readers (87.0% vs 78.0%, respectively; p = 0.011). Even though automated CAD-RADS classification uses data filled in by the readers, it outperforms manual classification by preventing human errors. Structured reporting platforms with automated calculation of the CAD-RADS score might improve data quality and support standardization of clinical decision making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Trends in CAD education in interior design programs

    OpenAIRE

    Ko, Hye Mi

    1990-01-01

    This research investigated Computer Aided Design (CAD) education in the interior design. program focusing on educators' opinions about creativity aspects including computer application, teaching materials and teaching methods as well as other trends in CAD education. A questionnaire was sent to one hundred eighty-two members of the Interior Design Educators Council (IDEC). A frequency distribution was used on 69 usable returned surveys to describe the sample characteristi...

  8. Trend and application of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-09-01

    This report is about trend and application of CAD/CAM system, giving descriptions of computer aided design which helps construction, engineering and drafting tasks. It also tells of computer aided manufacturing related general design of manufactures, which includes process design, production management, decision of work technology, processing. The need and application of CAD/CAM system is increasing more and more for industry each area.

  9. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    Science.gov (United States)

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...this time by allowing for rapid scanning, designing , development, and production of dental restorations. Using this technology gives dentists the

  10. Refining a brief decision aid in stable CAD: cognitive interviews

    OpenAIRE

    Kelly-Blake, Karen; Clark, Stacie; Dontje, Katherine; Olomu, Adesuwa; Henry, Rebecca C; Rovner, David R; Rothert, Marilyn L; Holmes-Rovner, Margaret

    2014-01-01

    Background We describe the results of cognitive interviews to refine the “Making Choices©” Decision Aid (DA) for shared decision-making (SDM) about stress testing in patients with stable coronary artery disease (CAD). Methods We conducted a systematic development process to design a DA consistent with International Patient Decision Aid Standards (IPDAS) focused on Alpha testing criteria. Cognitive interviews were conducted with ten stable CAD patients using the “think aloud” interview techniq...

  11. Customizing CAD system and its application for engineering design

    International Nuclear Information System (INIS)

    Shin, Jeong Ho; Kwak, Byung Man

    2003-01-01

    The computer is an important tool to design an engineering system and CAD systems are widely used for various design practice. To meet the market requirements, the old mass production system is being changed into the mass customization system. As for CAD systems, it is increasingly required to extend, automate, and customize a wide range of functionality. This article describes the state-of-the-art of the principal technologies for customizing CAD systems. And we have implemented an application that enables the parametric design by directly inputting numerical values of parameters for a CAD model. Based on this application, we have developed another system that makes it possible sharing of part family data between SolidEdge and Pro/Engineer. Through customization of CAD systems, it is possible to improve the product quality using external knowledge-based systems or to integrate with external system such as CAE tools. This paper can be a guide for engineering designers who want to customize CAD systems

  12. SLARette Mark 2 system

    International Nuclear Information System (INIS)

    Burnett, D.J.

    1992-01-01

    The SLAR (Spacer Location and Repositioning) program has developed the technology and tooling necessary to locate and reposition the fuel channel spacers that separate the pressure tube from the calandria tube in a CANDU reactor. The in-channel SLAR tool contains all the inspection probes, and is capable of moving spacers under remote control. The SLAR inspection computer system translates all eddy currents and ultrasonic signals from the in-channel tool into various graphic displays. The in-channel SLAR tool can be delivered and manipulated in a fuel channel by either a SLAR delivery machine or a SLARette delivery machine. The SLAR delivery machine consists of a modified fuelling machine, and is capable of operating under totally remote control in automatic or semi-automatic mode. The SLARette delivery machine is a smaller less automated version, which was designed to be quickly installed, operated, and removed from a limited number of fuel channels during regular annual maintenance outages. This paper describes the design and operation of the SLARette Mark 2 system. 5 figs

  13. Front panel engineering with CAD simulation tool

    Science.gov (United States)

    Delacour, Jacques; Ungar, Serge; Mathieu, Gilles; Hasna, Guenther; Martinez, Pascal; Roche, Jean-Christophe

    1999-04-01

    THe progress made recently in display technology covers many fields of application. The specification of radiance, colorimetry and lighting efficiency creates some new challenges for designers. Photometric design is limited by the capability of correctly predicting the result of a lighting system, to save on the costs and time taken to build multiple prototypes or bread board benches. The second step of the research carried out by company OPTIS is to propose an optimization method to be applied to the lighting system, developed in the software SPEOS. The main features of the tool requires include the CAD interface, to enable fast and efficient transfer between mechanical and light design software, the source modeling, the light transfer model and an optimization tool. The CAD interface is mainly a prototype of transfer, which is not the subjects here. Photometric simulation is efficiently achieved by using the measured source encoding and a simulation by the Monte Carlo method. Today, the advantages and the limitations of the Monte Carlo method are well known. The noise reduction requires a long calculation time, which increases with the complexity of the display panel. A successful optimization is difficult to achieve, due to the long calculation time required for each optimization pass including a Monte Carlo simulation. The problem was initially defined as an engineering method of study. The experience shows that good understanding and mastering of the phenomenon of light transfer is limited by the complexity of non sequential propagation. The engineer must call for the help of a simulation and optimization tool. The main point needed to be able to perform an efficient optimization is a quick method for simulating light transfer. Much work has been done in this area and some interesting results can be observed. It must be said that the Monte Carlo method wastes time calculating some results and information which are not required for the needs of the simulation

  14. The cinnamyl alcohol dehydrogenase (CAD gene family in flax (Linum usitatissimum L.: Insight from expression profiling of cads induced by elicitors in cultured flax cells

    Directory of Open Access Journals (Sweden)

    Eom Hee Seung

    2016-01-01

    Full Text Available Cinnamyl alcohol dehydrogenase (CAD is a key enzyme in the biosynthesis of lignin and lignans as it catalyzes the final step of monolignol biosynthesis, using NADPH as a cofactor. In higher plants, CAD is encoded by a multigene family consisting of three major classes. Based on the recently released flax (Linum usitatissimum L. whole-genome sequences, in this study we identified six CAD family genes that contain an ADH_N domain and an ADH_zinc_N domain, which suggests that the putative flax CADs (LuCADs are zinc-dependent alcohol dehydrogenases and members of the plant CAD family. In addition, expression analysis using quantitative real-time PCR revealed spatial variations in the expression of LuCADs in different organs. Comparative analysis between LuCAD enzymatic activity and LuCAD transcripts indicates that the variation of LuCAD enzymatic activities by elicitors is reflected by transcription of LuCADs in flax suspension-cultured cells. Taken together, our genome-wide analysis of CAD genes and the expression profiling of these genes provide valuable information for understanding the function of CADs, and will assist future studies on the physiological role of monolignols associated with plant defense.

  15. Different Routes for Conifer- and Sinapaldehyde and Higher Saccharification upon Deficiency in the Dehydrogenase CAD11[OPEN

    Science.gov (United States)

    Laurans, Françoise; Foster, Cliff; Légée, Frédéric

    2017-01-01

    In the search for renewable energy sources, genetic engineering is a promising strategy to improve plant cell wall composition for biofuel and bioproducts generation. Lignin is a major factor determining saccharification efficiency and, therefore, is a prime target to engineer. Here, lignin content and composition were modified in poplar (Populus tremula × Populus alba) by specifically down-regulating CINNAMYL ALCOHOL DEHYDROGENASE1 (CAD1) by a hairpin-RNA-mediated silencing approach, which resulted in only 5% residual CAD1 transcript abundance. These transgenic lines showed no biomass penalty despite a 10% reduction in Klason lignin content and severe shifts in lignin composition. Nuclear magnetic resonance spectroscopy and thioacidolysis revealed a strong increase (up to 20-fold) in sinapaldehyde incorporation into lignin, whereas coniferaldehyde was not increased markedly. Accordingly, ultra-high-performance liquid chromatography-mass spectrometry-based phenolic profiling revealed a more than 24,000-fold accumulation of a newly identified compound made from 8-8 coupling of two sinapaldehyde radicals. However, no additional cinnamaldehyde coupling products could be detected in the CAD1-deficient poplars. Instead, the transgenic lines accumulated a range of hydroxycinnamate-derived metabolites, of which the most prominent accumulation (over 8,500-fold) was observed for a compound that was identified by purification and nuclear magnetic resonance as syringyl lactic acid hexoside. Our data suggest that, upon down-regulation of CAD1, coniferaldehyde is converted into ferulic acid and derivatives, whereas sinapaldehyde is either oxidatively coupled into S′(8-8)S′ and lignin or converted to sinapic acid and derivatives. The most prominent sink of the increased flux to hydroxycinnamates is syringyl lactic acid hexoside. Furthermore, low-extent saccharification assays, under different pretreatment conditions, showed strongly increased glucose (up to +81%) and xylose

  16. Retrospective analysis of a Computer-Aided Detection (CAD) system in full-field digital mammography in correlation to tumor histology

    International Nuclear Information System (INIS)

    Obenauer, S.; Sohns, C.; Grabbe, E.; Werner, C.

    2005-01-01

    Purpose: to evaluate the usefulness of a computer-aided detection (CAD) system in full-field digital mammography in correlation to tumor histology. Material and methods: a total of 476 patients (226 patients with histologically proven malignant tumors, 250 healthy women) took part in this study. The mammograms were studied retrospectively, using the CAD system Image Checker. For 226 patients digital mammograms in MLO-projection were available. For 186 of these patients the CC-projection was also available. CAD markers that correlated with histologically proven carcinomas were considered to be true-positive markers. All other CAD markers were considered to be false-positive. Histologically proven carcinomas without markers were false-negative results. The dependence of the CAD markers placement upon the different carcinoma histologies was studied using the Chi-square test. Results: no significant difference could be proven for the detectability of malignant breast lesions of different histologic types. For the detectability of ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), lobular carcinoma in situ (LCIS), tubular carcinoma and ductulo-lobular carcinoma, the true positives were 71.1%, 75%, 70.7%, 70%, 60% and 80%, respectively, in the MLO projection and 83.9%, 75.9%, 81.8%, 77.8%, 87.5% and 33.3%, respectively, in the CC projection. There was an average of 0.5 false-positive markers per mammographic image. Conclusion: The histologic type of carcinoma seems to have no influence on detectability when using the CAD system. The high rate of false-positive markers shows, however, the limited specificity of the CAD system and that improvements are necessary. (orig.)

  17. XML-based assembly visualization for a multi-CAD digital mock-up system

    International Nuclear Information System (INIS)

    Song, In Ho; Chung, Sung Chong

    2007-01-01

    Using a virtual assembly tool, engineers are able to design accurate and interference free parts without making physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product in a distributed design environment. In this paper, a multi-CAD assembly method is proposed through an XML and the lightweight CAD file. XML data contains a hierarchy of the multi-CAD assembly. The lightweight CAD file produced from various CAD files through the ACIS kemel and InterOp includes not only mesh and B-Rep data, but also topological data. It is used to visualize CAD data and to verify dimensions of the parts. The developed system is executed on desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Multi-CAD models have been assembled to verify the effectiveness of the developed DMU system on the Internet

  18. Reproducibility of prompts in computer-aided detection (CAD) of breast cancer

    International Nuclear Information System (INIS)

    Taylor, C.G.; Champness, J.; Reddy, M.; Taylor, P.; Potts, H.W.W.; Given-Wilson, R.

    2003-01-01

    AIM: We evaluated the reproducibility of prompts using the R2 ImageChecker M2000 computer-aided detection (CAD) system. MATERIALS AND METHODS: Forty selected two-view mammograms of women with breast cancer were digitized and analysed using the ImageChecker on 10 separate occasions. The mammograms were chosen to provide both straightforward and subtle signs of malignancy. Data analysed included mammographic abnormality, pathology, and whether the cancer was prompted or given an emphasized prompt. RESULTS: Correct prompts were generated in 86 out of 100 occasions for screen-detected cancers. Reproducibility was less in the other categories of more subtle cancers: 21% for cancers previously missed by CAD, a group that contained more grade 1 and small (<10 mm) tumours. Prompts for calcifications were more reproducible than those for masses (76% versus 53%) and these cancers were more likely to have an emphasized prompt. CONCLUSIONS: Probably the most important cause of variability of prompts is shifts in film position between sequential digitizations. Consequently subtle lesions that are only just above the threshold for display may not be prompted on repeat scanning. However, users of CAD should be aware that even emphasized prompts are not consistently reproducible

  19. CAD/CAM glass ceramics for single-tooth implant crowns: a finite element analysis.

    Science.gov (United States)

    Akça, Kvanç; Cavusoglu, Yeliz; Sagirkaya, Elcin; Aybar, Buket; Cehreli, Murat Cavit

    2013-12-01

    To evaluate the load distribution of CAD/CAM mono-ceramic crowns supported with single-tooth implants in functional area. A 3-dimensional numerical model of a soft tissue-level implant was constructed with cement-retained abutment to support glass ceramic machinable crown. Implant-abutment complex and the retained crown were embedded in a Ø 1.5 × 1.5 cm geometric matrix for evaluation of mechanical behavior of mono-ceramic CAD/CAM aluminosilicate and leucite glass crown materials. Laterally positioned axial load of 300 N was applied on the crowns. Resulting principal stresses in the mono-ceramic crowns were evaluated in relation to different glass ceramic materials. The highest compressive stresses were observed at the cervical region of the buccal aspect of the crowns and were 89.98 and 89.99 MPa, for aluminosilicate and leucite glass ceramics, respectively. The highest tensile stresses were observed at the collar of the lingual part of the crowns and were 24.54 and 25.39 MPa, respectively. Stresses induced upon 300 N static loading of CAD/CAM aluminosalicate and leucite glass ceramics are below the compressive strength of the materials. Impact loads may actuate the progress to end failure of mono-ceramic crowns supported by metallic implant abutments.

  20. The application of CAD, CAE & CAM in development of butterfly valve’s disc

    Science.gov (United States)

    Asiff Razif Shah Ranjit, Muhammad; Hanie Abdullah, Nazlin

    2017-06-01

    The improved design of a butterfly valve disc is based on the concept of sandwich theory. Butterfly valves are mostly used in various industries such as oil and gas plant. The primary failure modes for valves are indented disc, keyways and shaft failure and the cavitation damage. Emphasis on the application of CAD, a new model of the butterfly valve’s disc structure was designed. The structure analysis was analysed using the finite element analysis. Butterfly valve performance factors can be obtained is by using Computational Fluid Dynamics (CFD) software to simulate the physics of fluid flow in a piping system around a butterfly valve. A comparison analysis was done using the finite element to justify the performance of the structure. The second application of CAE is the computational fluid flow analysis. The upstream pressure and the downstream pressure was analysed to calculate the cavitation index and determine the performance throughout each opening position of the valve. The CAM process was done using 3D printer to produce a prototype and analysed the structure in form of prototype. The structure was downscale fabricated based on the model designed initially through the application of CAD. This study is utilized the application of CAD, CAE and CAM for a better improvement of the butterfly valve’s disc components.

  1. Improving performance of breast cancer risk prediction using a new CAD-based region segmentation scheme

    Science.gov (United States)

    Heidari, Morteza; Zargari Khuzani, Abolfazl; Danala, Gopichandh; Qiu, Yuchen; Zheng, Bin

    2018-02-01

    Objective of this study is to develop and test a new computer-aided detection (CAD) scheme with improved region of interest (ROI) segmentation combined with an image feature extraction framework to improve performance in predicting short-term breast cancer risk. A dataset involving 570 sets of "prior" negative mammography screening cases was retrospectively assembled. In the next sequential "current" screening, 285 cases were positive and 285 cases remained negative. A CAD scheme was applied to all 570 "prior" negative images to stratify cases into the high and low risk case group of having cancer detected in the "current" screening. First, a new ROI segmentation algorithm was used to automatically remove useless area of mammograms. Second, from the matched bilateral craniocaudal view images, a set of 43 image features related to frequency characteristics of ROIs were initially computed from the discrete cosine transform and spatial domain of the images. Third, a support vector machine model based machine learning classifier was used to optimally classify the selected optimal image features to build a CAD-based risk prediction model. The classifier was trained using a leave-one-case-out based cross-validation method. Applying this improved CAD scheme to the testing dataset, an area under ROC curve, AUC = 0.70+/-0.04, which was significantly higher than using the extracting features directly from the dataset without the improved ROI segmentation step (AUC = 0.63+/-0.04). This study demonstrated that the proposed approach could improve accuracy on predicting short-term breast cancer risk, which may play an important role in helping eventually establish an optimal personalized breast cancer paradigm.

  2. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  3. [Tailored cranioplasty using CAD-CAM technology].

    Science.gov (United States)

    Vitanovics, Dusán; Major, Ottó; Lovas, László; Banczerowski, Péter

    2014-11-30

    cranioplasty. Combined with 3D CAD- CAM method excellent aesthetic and functional result was achieved. In our study no case of infection occured. Proper preoperative preparation is important.

  4. Mark Kostabi soovib muuta inimesi õnnelikumaks / Kalev Mark Kostabi

    Index Scriptorium Estoniae

    Kostabi, Kalev Mark, 1960-

    2008-01-01

    Kalev Mark Kostabi oma sisekujunduslikest eelistustest, ameeriklaste ja itaallaste kodude sisekujunduse erinevustest, kunstist kui ruumikujunduse ühest osast, oma New Yorgi ja Rooma korterite kujundusest

  5. Soft tissues stability of cad-cam and stock abutments in anterior regions: 2-year prospective multicentric cohort study.

    Science.gov (United States)

    Lops, Diego; Bressan, Eriberto; Parpaiola, Andrea; Sbricoli, Luca; Cecchinato, Denis; Romeo, Eugenio

    2015-12-01

    Aim of this study was to verify if the type of implant abutment manufacturing, stock or cad-cam, could influence the maintenance of stable gingival margins around single restorations in anterior areas. After 16 weeks of healing, implants (Osseospeed, Astra Tech Dental Implant) were positioned. Depending on the different fixture inclination and the thickness of buccal peri-implant soft tissue, abutment selection resulted in four groups: Group 1 (patients with zirconia ZirDesign(®) stock abutments), Group 2 (titanium stock TiDesign(®) abutments), Group 3 (zirconia cad-cam abutments), and Group 4 (titanium cad-cam abutments). The following parameters were assessed: buccal gingival margin modification (BGM). The modification of the implant gingival margin was followed at 1 and 2 years of follow-up. A computerized analysis was performed for measurements. Differences between soft tissue margin at baseline and after 2 years measured the gingival margin recession. A general linear model was used to evaluate each group in relation to gingival recession after two years. Tukey's post hoc test was used to compare the mean REC indexes of each group of abutments. Seventy-two healthy patients (39 males and 33 females; mean age of 46 years) scheduled for single gap rehabilitation in anterior areas were enrolled. A 100% of implant survival rate was observed after 24 months of function. One failure occurred due to fracture of a Zirconia cad-cam abutment. Moreover, two abutment screw unscrewing were observed. Both for zirconia and titanium stock abutments (Group 1 and 2), the mean recession of implant buccal soft tissue was of 0.3 mm (SD of 0.3 and 0.4 mm, respectively). Soft tissue mean recession of zirconia and titanium cad-cam abutments (Group 3 and 4) was of 0.1 and -0.3 mm, respectively (SD of 0.3 and 0.4 mm, respectively). REC values of cad-cam titanium abutments (Group 4) were significantly lower than that of Group 1 (-0.57 mm), Group 2 (-0.61 mm), and Group 3 (-0.40 mm

  6. Interferon-α induces marked alterations in circulating regulatory T cells, NK cell subsets, and dendritic cells in patients with JAK2V617F-positive essential thrombocythemia and polycythemia vera

    DEFF Research Database (Denmark)

    Riley, Caroline H; Brimnes, Marie K; Hansen, Morten

    2016-01-01

    Long-term therapy with IFN-α2 is associated with sustained major molecular remissions in JAK2-positive ET and PV. The efficacy of IFN-α2 may be partly mediated by modulation of immune cells, which was investigated in twenty patients with ET (n = 6) and PV (n = 14). The frequency of CD4+CD25+Foxp3...

  7. A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

    Science.gov (United States)

    Park, Ji-Man; Lee, Jai-Bong; Heo, Seong-Joo

    2014-01-01

    PURPOSE The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ±0.1 µm at 50 points. RESULTS Initial detorque values of milled abutment were significantly higher than those of cast abutment (P.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (Pabutment group and the cast abutment group after cyclic loading. CONCLUSION In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment. PMID:24605206

  8. Role of radiologists in CAD life-cycle

    International Nuclear Information System (INIS)

    Pietka, Ewa; Kawa, Jacek; Spinczyk, Dominik; Badura, Pawel; Wieclawek, Wojciech; Czajkowska, Joanna; Rudzki, Marcin

    2011-01-01

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  9. Role of radiologists in CAD life-cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pietka, Ewa, E-mail: ewa.pietka@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Kawa, Jacek, E-mail: jacek.kawa@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Spinczyk, Dominik, E-mail: dominik.spinczyk@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Badura, Pawel, E-mail: pawel.badura@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Wieclawek, Wojciech, E-mail: wojciech.wieclawek@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Czajkowska, Joanna, E-mail: joanna.czajkowska@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Rudzki, Marcin, E-mail: marcin.rudzki@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland)

    2011-05-15

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  10. The Enzyme Activity and Substrate Specificity of Two Major Cinnamyl Alcohol Dehydrogenases in Sorghum (Sorghum bicolor), SbCAD2 and SbCAD4.

    Science.gov (United States)

    Jun, Se-Young; Walker, Alexander M; Kim, Hoon; Ralph, John; Vermerris, Wilfred; Sattler, Scott E; Kang, ChulHee

    2017-08-01

    Cinnamyl alcohol dehydrogenase (CAD) catalyzes the final step in monolignol biosynthesis, reducing sinapaldehyde, coniferaldehyde, and p -coumaraldehyde to their corresponding alcohols in an NADPH-dependent manner. Because of its terminal location in monolignol biosynthesis, the variation in substrate specificity and activity of CAD can result in significant changes in overall composition and amount of lignin. Our in-depth characterization of two major CAD isoforms, SbCAD2 (Brown midrib 6 [bmr6]) and SbCAD4, in lignifying tissues of sorghum ( Sorghum bicolor ), a strategic plant for generating renewable chemicals and fuels, indicates their similarity in both structure and activity to Arabidopsis ( Arabidopsis thaliana ) CAD5 and Populus tremuloides sinapyl alcohol dehydrogenase, respectively. This first crystal structure of a monocot CAD combined with enzyme kinetic data and a catalytic model supported by site-directed mutagenesis allows full comparison with dicot CADs and elucidates the potential signature sequence for their substrate specificity and activity. The L119W/G301F-SbCAD4 double mutant displayed its substrate preference in the order coniferaldehyde > p -coumaraldehyde > sinapaldehyde, with higher catalytic efficiency than that of both wild-type SbCAD4 and SbCAD2. As SbCAD4 is the only major CAD isoform in bmr6 mutants, replacing SbCAD4 with L119W/G301F-SbCAD4 in bmr6 plants could produce a phenotype that is more amenable to biomass processing. © 2017 American Society of Plant Biologists. All Rights Reserved.

  11. NotaMark industrial laser marking system: a new security marking technology

    Science.gov (United States)

    Moreau, Vincent G.

    2004-06-01

    Up until now, the only variable alphanumeric data which could be added to banknotes was the number, applied by means of impact typographical numbering boxes. As an additional process or an alternative to this mechanical method, a non-contact laser marking process can be used offering high quality and greater levels of flexibility. For this purpose KBA-GIORI propose an exclusive laser marking solution called NotaMark. The laser marking process NotaMark is the ideal solution for applying variable data and personalizing banknotes (or any other security documents) with a very high resolution, for extremely large production volumes. A completely integrated solution has been developed comprised of laser light sources, marking head units, and covers and extraction systems. NotaMark allows the marking of variable data by removing locally and selectively, specific printed materials leaving the substrate itself untouched. A wide range of materials has already been tested extensively. NotaMark is a new security feature which is easy to identify and difficult to counterfeit, and which complies with the standard mechanical and chemical resistance tests in the security printing industry as well as with other major soiling tests. The laser marking process opens up a whole new range of design possibilities and can be used to create a primary security feature such as numbering, or to enhance the value of existing features.

  12. AutoCAD electrical 2013 for electrical control designers

    CERN Document Server

    Tickoo, Sham; CADCIM Technologies

    2013-01-01

    The AutoCAD Electrical 2013 for Electrical Control Designers textbook has been written to assist the engineering students and the practicing designers learn the application of various AutoCAD Electrical tools and options for creating electrical control designs. After reading this textbook, the users will be able to create professional electrical-control drawings easily and effectively. Moreover, the users will be able to automate various control engineering tasks such as building circuits, numbering wires, creating bills of materials, and many more. The textbook takes the users across a wide spectrum of electrical control drawings through progressive examples and numerous illustrations and exercises, thereby making it an ideal guide for both the novice and the advanced users. Salient Features of the Textbook Consists of 14 chapters that are organized in a pedagogical sequence covering various tools and features of AutoCAD Electrical such as schematic drawings, parametric and non-parametric PLC modules, Circu...

  13. Characterization analysis database system (CADS). A system overview

    International Nuclear Information System (INIS)

    1997-12-01

    The CADS database is a standardized, quality-assured, and configuration-controlled data management system developed to assist in the task of characterizing the DOE surplus HEU material. Characterization of the surplus HEU inventory includes identifying the specific material; gathering existing data about the inventory; defining the processing steps that may be necessary to prepare the material for transfer to a blending site; and, ultimately, developing a range of the preliminary cost estimates for those processing steps. Characterization focuses on producing commercial reactor fuel as the final step in material disposition. Based on the project analysis results, the final determination will be made as to the viability of the disposition path for each particular item of HEU. The purpose of this document is to provide an informational overview of the CADS database, its evolution, and its current capabilities. This document describes the purpose of CADS, the system requirements it fulfills, the database structure, and the operational guidelines of the system

  14. Integrated CAD/CAE for nuclear power plants

    International Nuclear Information System (INIS)

    Lecoq, P.; Lachat, J.C.

    1987-01-01

    The size of the French nuclear power program has led both EDF and Framatome to equip themselves progressively with management software, computer-assisted design (CAD) systems, and computer-assisted engineering (CAE) systems. The nature of the projects and of the respective activities of EDF and Framatome determined the essential specifications of these computerized systems. EDF and Framatome have pooled their CAD/CAE efforts in a joint venture (Groupement d'Interet Economique) called GIAO, set up in 1985 by EDF and Aquitaine Systeme (a subsidiary of Framatome and Elf Aquitaine). GIAO's ambition is to become a pole of French CAD/CAE efforts and to foster progress in integrated computer-assisted engineering, by enlarging the synergy of EDF and Framatome in this field to other enterprises that participate in design and construction of complex industrial plants

  15. The application of CAD / CAM technology in Dentistry

    Science.gov (United States)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  16. Mark 4A project training evaluation

    Science.gov (United States)

    Stephenson, S. N.

    1985-11-01

    A participant evaluation of a Deep Space Network (DSN) is described. The Mark IVA project is an implementation to upgrade the tracking and data acquisition systems of the dSN. Approximately six hundred DSN operations and engineering maintenance personnel were surveyed. The survey obtained a convenience sample including trained people within the population in order to learn what training had taken place and to what effect. The survey questionnaire used modifications of standard rating scales to evaluate over one hundred items in four training dimensions. The scope of the evaluation included Mark IVA vendor training, a systems familiarization training seminar, engineering training classes, a on-the-job training. Measures of central tendency were made from participant rating responses. Chi square tests of statistical significance were performed on the data. The evaluation results indicated that the effects of different Mark INA training methods could be measured according to certain ratings of technical training effectiveness, and that the Mark IVA technical training has exhibited positive effects on the abilities of DSN personnel to operate and maintain new Mark IVA equipment systems.

  17. Mark 4A project training evaluation

    Science.gov (United States)

    Stephenson, S. N.

    1985-01-01

    A participant evaluation of a Deep Space Network (DSN) is described. The Mark IVA project is an implementation to upgrade the tracking and data acquisition systems of the dSN. Approximately six hundred DSN operations and engineering maintenance personnel were surveyed. The survey obtained a convenience sample including trained people within the population in order to learn what training had taken place and to what effect. The survey questionnaire used modifications of standard rating scales to evaluate over one hundred items in four training dimensions. The scope of the evaluation included Mark IVA vendor training, a systems familiarization training seminar, engineering training classes, a on-the-job training. Measures of central tendency were made from participant rating responses. Chi square tests of statistical significance were performed on the data. The evaluation results indicated that the effects of different Mark INA training methods could be measured according to certain ratings of technical training effectiveness, and that the Mark IVA technical training has exhibited positive effects on the abilities of DSN personnel to operate and maintain new Mark IVA equipment systems.

  18. Marginal adaptation, fracture load and macroscopic failure mode of adhesively luted PMMA-based CAD/CAM inlays.

    Science.gov (United States)

    Ender, Andreas; Bienz, Stefan; Mörmann, Werner; Mehl, Albert; Attin, Thomas; Stawarczyk, Bogna

    2016-02-01

    To evaluate marginal adaptation, fracture load and failure types of CAD/CAM polymeric inlays. Standardized prepared human molars (48) were divided into four groups (n=12): (A) PCG (positive control group); adhesively luted glass-ceramic inlays, (B) TRX; CAD/CAM polymeric inlays luted using a self-adhesive resin cement, (C) TAC; CAD/CAM polymeric inlays luted using a conventional resin cement, and (D) NCG (negative control group); direct-filled resin-based composite restorations. All specimens were subjected to a chewing simulator. Before and after chewing fatigue, marginal adaptation was assessed at two interfaces: (1) between dental hard tissues and luting cement and (2) between luting cement and restoration. Thereafter, the specimens were loaded and the fracture loads, as well as the failure types, were determined. The data were analysed using three- and one-way ANOVA with post hoc Scheffé test, two sample Student's t-test (pmarginal adaptation for interface 1 showed significantly better results for TRX and PCG than for TAC (p=0.001-0.02) and NCG (p=0.001-0.047). For interface 2, marginal adaptation for TAC was significantly inferior to TRX (pmarginal adaptation of TAC and NCG. No significant differences in fracture load were found between all tested groups. Self-adhesive luted polymeric CAD/CAM inlays showed similar marginal adaptation and fracture load values compared to adhesively luted glass-ceramic inlays. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. AutoCAD platform customization user interface, AutoLISP, VBA, and beyond

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Take control of AutoCAD to boost the speed, quality, and precision of your work Senior drafters and savvy users are increasingly taking AutoCAD customization out of the hands of system administrators, and taking control of their own workflow. In AutoCAD Platform Customization, Autodesk customization guru Lee Ambrosius walks you through a multitude of customization options using detailed tutorials and real-world examples applicable to AutoCAD, AutoCAD LT, Civil 3D, Plant 3D, and other programs built on the AutoCAD platform. By unleashing the full power of the software, you'll simplify and str

  20. MEASURING INFORMATION INTEGR-ATION MODEL FOR CAD/CMM

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A CAD/CMM workpiece modeling system based on IGES file is proposed. The modeling system is implemented by using a new method for labelling the tolerance items of 3D workpiece. The concept-"feature face" is used in the method. First the CAD data of workpiece are extracted and recognized automatically. Then a workpiece model is generated, which is the integration of pure 3D geometry form with its corresponding inspection items. The principle of workpiece modeling is also presented. At last, the experiment results are shown and correctness of the model is certified.

  1. CAD system applications to the nuclear fuel reprocessing facilities

    International Nuclear Information System (INIS)

    Morita, Eiji; Matsumoto, Tadakuni; Shikakura, Sakae; Furuya, Kousei; Sakurai, Shin-ichi.

    1994-01-01

    Effective supporting techniques of design, operation, and maintenance of the reprocessing facility have been developed using the Intergraph CAD system. Two and three dimensional views of the process cells were utilized to rationalize the equipment layout and material handling flows, and to check the piping interference. Interferences of the remote maintenance equipment with the process equipments were also evaluated by the pictures on the CAD display. The newest virtual reality technology will help our future development of the more natural simulation for the remote maintenance operator training. (author)

  2. Particle tracking in sophisticated CAD models for simulation purposes

    International Nuclear Information System (INIS)

    Sulkimo, J.; Vuoskoski, J.

    1995-01-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT. (orig.)

  3. Particle tracking in sophisticated CAD models for simulation purposes

    Science.gov (United States)

    Sulkimo, J.; Vuoskoski, J.

    1996-02-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT.

  4. CAD/CAM: improved design quality, increased productivity

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D. E.; England, J.

    1980-01-01

    Maintaining productivity levels while assuring the quality of engineering products grows increasingly more difficult and costly for industries such as the energy industry which are heavily committed to product design. The man/machine interface made possible through the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology can be applied to the design process as a tool for increased control to assure the quality of the final engineering product. The quality-control aspects of CAD/CAM technology are addressed in this presentation.

  5. Instant Autodesk AutoCAD 2014 customization with .NET

    CERN Document Server

    Nelson, Tom

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. An instruction-based guide with examples written in the C# programming language. VB.NET programmers can also take advantage of these examples by using one of the free conversion websites to convert the examples to VB.NET.Clear, step-by-step instructions and complete code examples illustrate the processes, making it easy to develop your own custom AutoCAD tools.This book is perfect if you are interested in customizing AutoCAD 2014 using the .NET API. You should have a basic familiari

  6. Transcriptome-wide identification and characterization of CAD isoforms specific for podophyllotoxin biosynthesis from Podophyllum hexandrum.

    Science.gov (United States)

    Bhattacharyya, Dipto; Hazra, Saptarshi; Banerjee, Anindyajit; Datta, Riddhi; Kumar, Deepak; Chakrabarti, Saikat; Chattopadhyay, Sharmila

    2016-09-01

    Podophyllotoxin (ptox) is a therapeutically important lignan derived from Podophyllum hexandrum and is used as a precursor for the synthesis of anticancer drugs etoposide, teniposide and etopophose. In spite of its enormous economic significance, genomic information on this endangered medicinal herb is scarce. We have performed de novo transcriptome analysis of methyl jasmonate (MeJA)-treated P. hexandrum cell cultures exhibiting enhanced ptox accumulation. The results revealed the maximum up-regulation of several isoforms of cinnamyl alcohol dehydrogenase (CAD). CAD catalyzes the synthesis of coniferyl alcohol and sinapyl alcohol from coniferaldehyde (CAld) and sinapaldehyde respectively. Coniferyl alcohol can produce both lignin and lignan while sinapyl alcohol produces only lignin. To isolate the CAD isoforms favoring ptox, we deduced full length cDNA sequences of four CAD isoforms: PhCAD1, PhCAD2, PhCAD3 and PhCAD4 from the contigs of the transcriptome data. In vitro enzyme assays indicated a higher affinity for CAld over sinapaldehyde for each isoform. In silico molecular docking analyses also suggested that PhCAD3 has a higher binding preference with CAld over sinapaldehyde, followed by PhCAD4, PhCAD2, and PhCAD1, respectively. The transgenic cell cultures overexpressing these isoforms independently revealed that PhCAD3 favored the maximum accumulation of ptox as compared to lignin followed by PhCAD4 and PhCAD2, whereas, PhCAD1 favored both equally. Together, our study reveals transcriptome-wide identification and characterization of ptox specific CAD isoforms from P. hexandrum. It provides a useful resource for future research not only on the ptox biosynthetic pathway but on overall P. hexandrum, an endangered medicinal herb with immense therapeutic importance.

  7. Annotation and retrieval system of CAD models based on functional semantics

    Science.gov (United States)

    Wang, Zhansong; Tian, Ling; Duan, Wenrui

    2014-11-01

    CAD model retrieval based on functional semantics is more significant than content-based 3D model retrieval during the mechanical conceptual design phase. However, relevant research is still not fully discussed. Therefore, a functional semantic-based CAD model annotation and retrieval method is proposed to support mechanical conceptual design and design reuse, inspire designer creativity through existing CAD models, shorten design cycle, and reduce costs. Firstly, the CAD model functional semantic ontology is constructed to formally represent the functional semantics of CAD models and describe the mechanical conceptual design space comprehensively and consistently. Secondly, an approach to represent CAD models as attributed adjacency graphs(AAG) is proposed. In this method, the geometry and topology data are extracted from STEP models. On the basis of AAG, the functional semantics of CAD models are annotated semi-automatically by matching CAD models that contain the partial features of which functional semantics have been annotated manually, thereby constructing CAD Model Repository that supports model retrieval based on functional semantics. Thirdly, a CAD model retrieval algorithm that supports multi-function extended retrieval is proposed to explore more potential creative design knowledge in the semantic level. Finally, a prototype system, called Functional Semantic-based CAD Model Annotation and Retrieval System(FSMARS), is implemented. A case demonstrates that FSMARS can successfully botain multiple potential CAD models that conform to the desired function. The proposed research addresses actual needs and presents a new way to acquire CAD models in the mechanical conceptual design phase.

  8. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    Energy Technology Data Exchange (ETDEWEB)

    Messerli, Michael, E-mail: Michael.Messerli@usz.ch [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Kluckert, Thomas; Knitel, Meinhard [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Rengier, Fabian [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg (Germany); Warschkow, René [Department of Surgery, Cantonal Hospital St. Gallen (Switzerland); Alkadhi, Hatem [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Leschka, Sebastian [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Wildermuth, Simon; Bauer, Ralf W. [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland)

    2016-12-15

    Highlights: • Computer-aided detection (CAD) of solid pulmonary nodules was compared in 202 patients in standard dose and ultralow dose CT. • The per–nodule sensitivity of CAD was 70% in standard dose CT and 68% in ultralow dose CT. • The per–nodule sensitivity of CAD in standard dose CT was similar to ultralow dose CT in all size subgroups (all p > 0.05). • Adding CAD markings in ultralow dose CT significantly improved the sensitivity of two radiologists from 77% to 88% and from 66% to 79%, respectively. • CAD can serve as an excellent second reader for nodule detection in CT even at dose levels similar to chest X-ray. - Abstract: Objectives: To determine the value of computer-aided detection (CAD) for solid pulmonary nodules in ultralow radiation dose single-energy computed tomography (CT) of the chest using third-generation dual-source CT at 100 kV and fixed tube current at 70 mAs with tin filtration. Methods: 202 consecutive patients undergoing clinically indicated standard dose chest CT (1.8 ± 0.7 mSv) were prospectively included and scanned with an additional ultralow dose CT (0.13 ± 0.01 mSv) in the same session. Standard of reference (SOR) was established by consensus reading of standard dose CT by two radiologists. CAD was performed in standard dose and ultralow dose CT with two different reconstruction kernels. CAD detection rate of nodules was evaluated including subgroups of different nodule sizes (<5, 5–7, >7 mm). Sensitivity was further analysed in multivariable mixed effects logistic regression. Results: The SOR included 279 solid nodules (mean diameter 4.3 ± 3.4 mm, range 1–24 mm). There was no significant difference in per–nodule sensitivity of CAD in standard dose with 70% compared to 68% in ultralow dose CT both overall and in different size subgroups (all p > 0.05). CAD led to a significant increase of sensitivity for both radiologists reading the ultralow dose CT scans (all p < 0.001). In multivariable analysis, the use

  9. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    International Nuclear Information System (INIS)

    Messerli, Michael; Kluckert, Thomas; Knitel, Meinhard; Rengier, Fabian; Warschkow, René; Alkadhi, Hatem; Leschka, Sebastian; Wildermuth, Simon; Bauer, Ralf W.

    2016-01-01

    Highlights: • Computer-aided detection (CAD) of solid pulmonary nodules was compared in 202 patients in standard dose and ultralow dose CT. • The per–nodule sensitivity of CAD was 70% in standard dose CT and 68% in ultralow dose CT. • The per–nodule sensitivity of CAD in standard dose CT was similar to ultralow dose CT in all size subgroups (all p > 0.05). • Adding CAD markings in ultralow dose CT significantly improved the sensitivity of two radiologists from 77% to 88% and from 66% to 79%, respectively. • CAD can serve as an excellent second reader for nodule detection in CT even at dose levels similar to chest X-ray. - Abstract: Objectives: To determine the value of computer-aided detection (CAD) for solid pulmonary nodules in ultralow radiation dose single-energy computed tomography (CT) of the chest using third-generation dual-source CT at 100 kV and fixed tube current at 70 mAs with tin filtration. Methods: 202 consecutive patients undergoing clinically indicated standard dose chest CT (1.8 ± 0.7 mSv) were prospectively included and scanned with an additional ultralow dose CT (0.13 ± 0.01 mSv) in the same session. Standard of reference (SOR) was established by consensus reading of standard dose CT by two radiologists. CAD was performed in standard dose and ultralow dose CT with two different reconstruction kernels. CAD detection rate of nodules was evaluated including subgroups of different nodule sizes (<5, 5–7, >7 mm). Sensitivity was further analysed in multivariable mixed effects logistic regression. Results: The SOR included 279 solid nodules (mean diameter 4.3 ± 3.4 mm, range 1–24 mm). There was no significant difference in per–nodule sensitivity of CAD in standard dose with 70% compared to 68% in ultralow dose CT both overall and in different size subgroups (all p > 0.05). CAD led to a significant increase of sensitivity for both radiologists reading the ultralow dose CT scans (all p < 0.001). In multivariable analysis, the use

  10. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Im, Jong Pil; Kim, Sang Gyun [Department of Internal Medicine, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2015-04-15

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  11. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    International Nuclear Information System (INIS)

    Lee, Eun Sun; Kim, Se Hyung; Im, Jong Pil; Kim, Sang Gyun; Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn

    2015-01-01

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  12. Reconstruction of Consistent 3d CAD Models from Point Cloud Data Using a Priori CAD Models

    Science.gov (United States)

    Bey, A.; Chaine, R.; Marc, R.; Thibault, G.; Akkouche, S.

    2011-09-01

    We address the reconstruction of 3D CAD models from point cloud data acquired in industrial environments, using a pre-existing 3D model as an initial estimate of the scene to be processed. Indeed, this prior knowledge can be used to drive the reconstruction so as to generate an accurate 3D model matching the point cloud. We more particularly focus our work on the cylindrical parts of the 3D models. We propose to state the problem in a probabilistic framework: we have to search for the 3D model which maximizes some probability taking several constraints into account, such as the relevancy with respect to the point cloud and the a priori 3D model, and the consistency of the reconstructed model. The resulting optimization problem can then be handled using a stochastic exploration of the solution space, based on the random insertion of elements in the configuration under construction, coupled with a greedy management of the conflicts which efficiently improves the configuration at each step. We show that this approach provides reliable reconstructed 3D models by presenting some results on industrial data sets.

  13. In-office bleaching efficacy on stain removal from CAD/CAM and direct resin composite materials.

    Science.gov (United States)

    Alharbi, Amal; Ardu, Stefano; Bortolotto, Tissiana; Krejci, Ivo

    2018-01-01

    To evaluate the efficacy of in-office bleaching on stain removal from stained resin composite and ceramic computer-assisted design/computer-assisted manufacturing (CAD/CAM) blocks and direct resin composites. Forty disk-shaped samples were fabricated from each of nine materials: six CAD/CAM (VITABLOCS Mark II, Paradigm MZ100, Exp Vita Hybrid Ceramic, VITA ENAMIC, Exp Kerr, and LAVA Ultimate) and three direct resin composites (Filtek Supreme, Venus Diamond, and Filtek Silorane). Samples were randomly divided into five groups (n = 8), each stained with a particular staining solution. Using a calibrated spectrophotometer and a black background, L*a*b* values were assessed before and after 120 days of staining. Samples were subjected to in-office bleaching using 40% hydrogen peroxide gel for one hour. At subsequent assessment, color change (ΔE) was calculated as the difference between L*a*b* values. Both ANOVA and the Duncan test were used to identify differences between groups (α = 0.05). Bleaching resulted in significant differences in ΔE values for all materials (P Bleaching efficacy was highly influenced by material composition and staining solution. Residual color values after bleaching for ceramic and hybrid ceramics ranged from -0.49 to 2.35, within the clinically acceptable maximum of 3.3. Values after bleaching for resin-based CAD/CAM ranged from -0.7 to 7.08 while direct resin composites values ranged from -1.47 to 25.13. Coffee left the greatest residual color on all materials. Based on material nature, 40% hydrogen peroxide bleaching can remove staining. The new resin-based CAD/CAM blocks showed promising results in terms of color stability. Bleaching using 40% hydrogen peroxide can be an effective method to remove stains from dental restorations. In this way, restoration replacement as a result of discoloration may no longer be necessary. © 2017 Wiley Periodicals, Inc.

  14. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  15. On CAD-integrated Structural Topology and Design Optimization

    DEFF Research Database (Denmark)

    Olhoff, Niels; Bendsøe, M.P.; Rasmussen, John

    1991-01-01

    Concepts underlying an interactive CAD-based engineering design optimization system are developed, and methods of optimizing the topology, shape and sizing of mechanical components are presented. These methods are integrated in the system, and the method for determining the optimal topology is used...

  16. Individualized Human CAD Models: Anthropmetric Morphing and Body Tissue Layering

    Science.gov (United States)

    2014-07-31

    fat thickness may not be uniform and an estimation of this inhomogeneity is integrated into the sub-assemblies of the CAD model. For example, the...Xu X, Endrusick T, Santee W and Kokla M. Simulation of toe thermal responses to cold exposure while wearing protective footwear . SAE 2005

  17. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  18. Correlating Trainee Attributes to Performance in 3D CAD Training

    Science.gov (United States)

    Hamade, Ramsey F.; Artail, Hassan A.; Sikstrom, Sverker

    2007-01-01

    Purpose: The purpose of this exploratory study is to identify trainee attributes relevant for development of skills in 3D computer-aided design (CAD). Design/methodology/approach: Participants were trained to perform cognitive tasks of comparable complexity over time. Performance data were collected on the time needed to construct test models, and…

  19. Present State of CAD Teaching in Spanish Universities

    Science.gov (United States)

    Garcia, Ramon Rubio; Santos, Ramon Gallego; Quiros, Javier Suarez; Penin, Pedro I. Alvarez

    2005-01-01

    During the 1990s, all Spanish Universities updated the syllabuses of their courses as a result of the entry into force of the new Organic Law of Universities ("Ley Organica de Universidades") and, for the first time, "Computer Assisted Design" (CAD) appears in the list of core subjects (compulsory teaching content set by the…

  20. Program Evolves from Basic CAD to Total Manufacturing Experience

    Science.gov (United States)

    Cassola, Joel

    2011-01-01

    Close to a decade ago, John Hersey High School (JHHS) in Arlington Heights, Illinois, made a transition from a traditional classroom-based pre-engineering program. The new program is geared towards helping students understand the entire manufacturing process. Previously, a JHHS student would design a project in computer-aided design (CAD) software…

  1. Alternatives for Saving and Viewing CAD Graphics for the Web.

    Science.gov (United States)

    Harris, La Verne Abe; Sadowski, Mary A.

    2001-01-01

    Introduces some alternatives for preparing and viewing computer aided design (CAD) graphics for Internet output on a budget, without the fear of copyright infringement, and without having to go back to college to learn a complex graphic application. (Author/YDS)

  2. Fatigue resistance of CAD/CAM resin composite molar crowns.

    NARCIS (Netherlands)

    Shembish, F.A.; Tong, H.; Kaizer, M.; Janal, M.N.; Thompson, V.P.; Opdam, N.J.M.; Zhang, Y.

    2016-01-01

    OBJECTIVE: To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. METHODS: Fully anatomically shaped monolithic resin composite molar crowns (Lava

  3. Schools (Students) Exchanging CAD/CAM Files over the Internet.

    Science.gov (United States)

    Mahoney, Gary S.; Smallwood, James E.

    This document discusses how students and schools can benefit from exchanging computer-aided design/computer-aided manufacturing (CAD/CAM) files over the Internet, explains how files are exchanged, and examines the problem of selected hardware/software incompatibility. Key terms associated with information search services are defined, and several…

  4. Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

    Directory of Open Access Journals (Sweden)

    Suk-Ho Kang

    2013-08-01

    Full Text Available Objectives There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent and Rosetta SM (Hass, and to observe their crystalline structures. Materials and Methods Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi and x-ray diffraction (XRD, Rigaku analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05. The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.

  5. User interface issues in radiotherapy CAD software. 116

    International Nuclear Information System (INIS)

    Sherouse, G.W.; Mosher, C.E. Jr.

    1987-01-01

    A major growth area in computerized planning of radiotherapy over the last five years has been the development of programs for treatment design based on the interactive graphic display of three dimensional patient models. This word has been recognized as being a close relative of Computer-Aided Design (CAD) software which is used in industry for a broad spectrum of engineering and design applications. A CAD system for radiotherapy has been constructed which combines some of the more attractive aspects of other institutions' treatment design systems with CAD technology and a user interface which is designed for use by clinicians. The importance of an appropriate user interface cannot be overemphasized and is often sadly neglected in radiotherapy software. In order to realize the potential of this new treatment design technology it is essential that clinicians, particularly physicians, perceive RT CAD systems as tools rather than as obstacles. It is felt that thhe best way to achieve that perception is for the software to implement a superset of the functions used in conventional practice while retaining the ambiance of the traditional methods. It is the aim to construct a system which an experienced physician or dosimetrist can use with essentially no retraining. The model for this CAD tool is that of a virtual simulator. It is meant to faithfully reproduce both the function and the feel of a physical simulator. A number of techniques has been identified for realizing this goal. These include simple intuitive input devices, natural coordinate systems graphic interaction, good interactive responsiveness, and high-quality 3D display modalities. Here a description of these techniques and some details of their implementation is presented. 10 refs.; 2 figs

  6. Assessment of the Use of AutoCAD in Mechanical Engineering Technical Drawing Education

    OpenAIRE

    Akyürek, Turgut

    2018-01-01

    AutoCAD is one of the widely used software tools in engineering education. In this study, ageneral assessment of AutoCAD for the usage in the mechanical engineering technical drawing educationis made. AutoCAD is assessed in terms of the fulfilment of the requirements defined for the main twotechnical drawing courses. AutoCAD is assessed in terms of its capability in meeting the requirements ofthe technical drawing courses.

  7. Longevity of Single-Tooth All-Ceramic CAD/CAM Restorations: A Meta-Analysis

    Science.gov (United States)

    2013-07-01

    to the application of CAD/CAM technology in dentistry . The initial monetary investment for the equipment is significant. Systems currently on the...CURRENT DENTAL CAD/CAM SYSTEMS Current CAD/CAM systems in dentistry include: CEREC (CEramic REConstruction) and CEREC Acquisition Center (AC) with...of Adhesive Dentistry , 1 (3), 255- 265. 42     Bindl A, & Mörmann W. (2002). An up to 5-year clinical evaluation of posterior In- Ceram CAD

  8. Research on remote sensing image pixel attribute data acquisition method in AutoCAD

    Science.gov (United States)

    Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui

    2013-07-01

    The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.

  9. The dynamic interaction of order flows and the CAD/USD exchange rate

    OpenAIRE

    Nikola Gradojevic; Christopher J. Neely

    2008-01-01

    We explore the relationship between disaggregated order flow, the Canada/U.S. dollar (CAD/USD) market and U.S. macroeconomic announcements. Three types of CAD order flow and the CAD/USD are cointegrated. Financial order flow appears to contemporaneously drive the CAD/USD while commercial order flow seems to contemporaneously respond to exchange rate movements. Past order flow and lagged exchange rates strongly explain most types of order flow. Despite this predictability and the contemporaneo...

  10. Civilsamfundets ABC: M for Marked

    DEFF Research Database (Denmark)

    Lund, Anker Brink; Meyer, Gitte

    2016-01-01

    Bogstaveligt talt: Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til M for Marked.......Bogstaveligt talt: Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til M for Marked....

  11. Marks on the petroleum fiscality

    International Nuclear Information System (INIS)

    2007-02-01

    This document offers some marks on the petroleum fiscality in France: the taxes as the 'accises' and the 'TVA', the part of the taxes in the sale price at the service station, the comparison with other countries of Europe, the tax revenues and the Government budget. It provides also marks on the fuels prices formation (margins), the world petroleum markets (supply and demand) and the part of the petroleum companies on the petroleum market. (A.L.B.)

  12. Automation in the Teaching of Descriptive Geometry and CAD. High-Level CAD Templates Using Script Languages

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study improvements to the learning method of technical drawing and descriptive geometry through exercises with traditional techniques that are usually solved manually by applying automated processes assisted by high-level CAD templates (HLCts). Given that an exercise with traditional procedures can be solved, detailed step by step in technical drawing and descriptive geometry manuals, CAD applications allow us to do the same and generalize it later, incorporating references. Traditional teachings have become obsolete and current curricula have been relegated. However, they can be applied in certain automation processes. The use of geometric references (using variables in script languages) and their incorporation into HLCts allows the automation of drawing processes. Instead of repeatedly creating similar exercises or modifying data in the same exercises, users should be able to use HLCts to generate future modifications of these exercises. This paper introduces the automation process when generating exercises based on CAD script files, aided by parametric geometry calculation tools. The proposed method allows us to design new exercises without user intervention. The integration of CAD, mathematics, and descriptive geometry facilitates their joint learning. Automation in the generation of exercises not only saves time but also increases the quality of the statements and reduces the possibility of human error.

  13. Cam Design Projects in an Advanced CAD Course for Mechanical Engineers

    Science.gov (United States)

    Ault, H. K.

    2009-01-01

    The objective of this paper is to present applications of solid modeling aimed at modeling of complex geometries such as splines and blended surfaces in advanced CAD courses. These projects, in CAD-based Mechanical Engineering courses, are focused on the use of the CAD system to solve design problems for applications in machine design, namely the…

  14. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    Science.gov (United States)

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  15. Cause or effect of arteriogenesis: compositional alterations of microparticles from CAD patients undergoing external counterpulsation therapy.

    Science.gov (United States)

    Al Kaabi, Ali; Traupe, Tobias; Stutz, Monika; Buchs, Natasha; Heller, Manfred

    2012-01-01

    Recently, a clinical study on patients with stable coronary artery disease (CAD) showed that external counterpulsation therapy (ECP) at high (300 mmHg) but not at low inflation pressure (80 mmHg) promoted coronary collateral growth, most likely due to shear stress-induced arteriogenesis. The exact molecular mechanisms behind shear stress-induced arteriogenesis are still obscure. We therefore characterized plasma levels of circulating microparticles (MPs) from these CAD patients because of their ambivalent nature as a known cardiovascular risk factor and as a promoter of neovascularization in the case of platelet-derived MPs. MPs positive for Annexin V and CD31CD41 were increased, albeit statistically significant (Pcollateral flow index (CFI), a measure for collateral growth. MPs from the high inflation pressure group had a more sustained pro-angiogenic effect than the ones from the low inflation pressure group, with the exception of one patient showing also an increased CFI after treatment. A total of 1005 proteins were identified by a label-free proteomics approach from MPs of three patients of each group applying stringent acceptance criteria. Based on semi-quantitative protein abundance measurements, MPs after ECP therapy contained more cellular proteins and increased CD31, corroborating the increase in MPs. Furthermore, we show that MP-associated factors of the innate immune system were decreased, many membrane-associated signaling proteins, and the known arteriogenesis stimulating protein transforming growth factor beta-1 were increased after ECP therapy. In conclusion, our data show that ECP therapy increases platelet-derived MPs in patients with CAD and that the change in protein cargo of MPs is likely in favor of a pro angiogenic/arteriogenic property. ClinicalTrials.gov NCT00414297.

  16. Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.

  17. BWR Mark I pressure suppression study: bench mark experiments

    International Nuclear Information System (INIS)

    Lai, W.; McCauley, E.W.

    1977-01-01

    Computer simulations representative of the wetwell of Mark I BWR's have predicted pressures and related phenomena. However, calculational predictions for purposes of engineering decision will be possible only if the code can be verified, i.e., shown to compute in accord with measured values. Described in the report is a set of single downcomer spherical flask bench mark experiments designed to produce quantitative data to validate various air-water dynamic computations; the experiments were performed since relevant bench mark data were not available from outside sources. Secondary purposes of the study were to provide a test bed for the instrumentation and post-experiment data processing techniques to be used in the Laboratory's reactor safety research program and to provide additional masurements for the air-water scaling study

  18. Electrode position markedly affects knee torque in tetanic, stimulated contractions.

    Science.gov (United States)

    Vieira, Taian M; Potenza, Paolo; Gastaldi, Laura; Botter, Alberto

    2016-02-01

    The purpose of this study was to investigate how much the distance between stimulation electrodes affects the knee extension torque in tetanic, electrically elicited contractions. Current pulses of progressively larger amplitude, from 0 mA to maximally tolerated intensities, were delivered at 20 pps to the vastus medialis, rectus femoris and vastus lateralis muscles of ten, healthy male subjects. Four inter-electrode distances were tested: 32.5% (L1), 45.0% (L2), 57.5% (L3) and 70% (L4) of the distance between the patella apex and the anterior superior iliac spine. The maximal knee extension torque and the current leading to the maximal torque were measured and compared between electrode configurations. The maximal current tolerated by each participant ranged from 60 to 100 mA and did not depend on the inter-electrode distance. The maximal knee extension torque elicited did not differ between L3 and L4 (P = 0.15) but, for both conditions, knee torque was significantly greater than for L1 and L2 (P torque elicited for L3 and L4 was two to three times greater than that obtained for L1 and L2. The current leading to maximal torque was not as sensitive to inter-electrode distance. Except for L1 current intensity did not change with electrode configuration (P > 0.16). Key results presented here revealed that for a given stimulation intensity, knee extension torque increased dramatically with the distance between electrodes. The distance between electrodes seems therefore to critically affect knee torque, with potential implication for optimising exercise protocols based on electrical stimulation.

  19. Accurate lateral positioning from map data and road marking detection

    OpenAIRE

    GRUYER, Dominique; BELAROUSSI, Rachid; REVILLOUD, Marc

    2015-01-01

    We are witnessing the clash of two industries and the remaking of in-car market order, as the world of digital knowledge recently made a significant move toward the automotive industry. Mobile operating system providers are battling between each other to take over the in-vehicle entertainment and information systems, while car makers either line up behind their technology or try to keep control over the in-car experience. What is at stake is the map content and location-based services, two ke...

  20. CAD/CAM for Double Woven Fabric

    Directory of Open Access Journals (Sweden)

    Moussa Alali

    2014-02-01

    Full Text Available To bond the two layers in double fabrics, various types of stitching can be distinguished such as self-stitching, double stitching, center warp stitching, center weft stitching, and so on. In this article, a mathematic model based on a software program has been developed to automatically generate a double fabric stitched by additional warp called center warp. Each layer has been represented in a 2D binary matrix, and a new matrix called warps order matrix has been defined to demonstrate the modality of position of the center warps in relating to the top and bottom fabrics’ warps. After insertion of all warps in the extended weave matrix, the lifter conditions has been discussed and the stitching points have been determined.

  1. Software planning and analysis for automated design system AutoCAD

    OpenAIRE

    Koskutė, Lina

    2007-01-01

    AutoCAD sistemos papildymas sukurtas tam, kad būtų lengviau ir paprasčiau dirbti su AutoCAD grafine sistema. Funkcijos sukurtos naudojant AutoLisp ir VisualLISP programavimo kalbas. Sistemos papildymą galima įdiegti į bet kurią AutoCAD versiją. Sukurtas papildymas lankstus naujų funkcijų prijungimui, lengvai eksploatuojamas. Funkcijos suskirstytos į keletą grupių pagal jų formatą. AutoCAD system complement is created to make more easy working with AutoCAD graphic system. Functions are crea...

  2. Revised Mark 22 coolant temperature coefficients

    International Nuclear Information System (INIS)

    Graves, W.E.

    1987-01-01

    Coolant temperature coefficients for the Mark 22 charge published previously are non-conservative because of the neglect of a significant mechanism which has a positive contribution to reactivity. Even after correcting for this effect, dynamic tests made on a Mark VIB charge in the early 60's suggest the results are still non-conservative. This memorandum takes both of these sources of information into account in making a best estimate of the prompt (coolant plus metal) temperature coefficient. Although no safety issues arise from this work (the overall temperature coefficient still strongly contributes to reactor stability), it is obviously desirable to use best estimates for prompt coefficients in limits and other calculations

  3. Mark Napier / Mark Napier ; interv. Tilman Baumgärtel

    Index Scriptorium Estoniae

    Napier, Mark

    2006-01-01

    Ameerika kunstnikust Mark Napierist (sünd. 1961) ja tema loomingust, 2001. a. tehtud meiliintervjuu kunstnikuga. Võrguteosest "The Digital Landfill" (1998), koos Andy Deckiga loodud tööst "GrafficJam" (1999), töödest "Shredder" (1998), "Feed", "Riot", "P-Soup" (2000), võrgukunstist ja muust

  4. Detection of a putative virulence cadF gene of Campylobacter jejuni obtained from different sources using a microfabricated PCR chip

    DEFF Research Database (Denmark)

    Poulsen, Claus Riber; El-Ali, Jamil; Perch-Nielsen, Ivan R.

    2005-01-01

    A microfabricated polymerase chain reaction (PCR) chip made of epoxy-based photoresist (SU-8) was recently designed and developed. In this study, we tested whether the PCR chip could be used for rapid detection of a potential virulence determinant, the cadF gene of Campylobacter jejuni. PCR...... was performed using published PCR conditions and primers for the C. jejuni cadF gene. DNA isolated from a C. jejuni reference strain CCUG 11284, C. jejuni isolates obtained from different sources (chicken and human), and Campylobacter whole cells were used as templates in the PCR tests. Conventional PCR in tube...... was used as the control. After optimization of the PCR chip, PCR positives on the chip were obtained from 91.0% (10/11) of the tested chips. A fast transition time was achieved with the PCR chip, and therefore a faster cycling time and a shorter PCR program were obtained. Using the PCR chip, the cadF gene...

  5. Minimal Marking: A Success Story

    Directory of Open Access Journals (Sweden)

    Anne McNeilly

    2014-11-01

    Full Text Available The minimal-marking project conducted in Ryerson’s School of Journalism throughout 2012 and early 2013 resulted in significantly higher grammar scores in two first-year classes of minimally marked university students when compared to two traditionally marked classes. The “minimal-marking” concept (Haswell, 1983, which requires dramatically more student engagement, resulted in more successful learning outcomes for surface-level knowledge acquisition than the more traditional approach of “teacher-corrects-all.” Results suggest it would be effective, not just for grammar, punctuation, and word usage, the objective here, but for any material that requires rote-memory learning, such as the Associated Press or Canadian Press style rules used by news publications across North America.

  6. The evaluation of multi-structure, multi-atlas pelvic anatomy features in a prostate MR lymphography CAD system

    Science.gov (United States)

    Meijs, M.; Debats, O.; Huisman, H.

    2015-03-01

    In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.

  7. Mechanical properties of resin-ceramic CAD/CAM restorative materials.

    Science.gov (United States)

    Awada, Abdallah; Nathanson, Dan

    2015-10-01

    The recent development of polymer-based computer-aided design and computer-aided manufactured (CAD/CAM) milling blocks and the limited availability of independent studies on these materials make it pertinent to evaluate their properties and identify potential strengths and limitations. The purpose of this in vitro study was to determine and compare mechanical properties (flexural strength, flexural modulus, modulus of resilience) and compare the margin edge quality of recently introduced polymer-based CAD/CAM materials with some of their commercially available composite resin and ceramic counterparts. The materials studied were Lava Ultimate Restorative (LVU; 3M ESPE), Enamic (ENA; Vita Zahnfabrik), Cerasmart (CES; GC Dental Products), IPS Empress CAD (EMP; Ivoclar Vivadent AG), Vitablocs Mark II (VM2; Vita Zahnfabrik), and Paradigm MZ100 Block (MZ1; 3M ESPE). Polished 4×1×13.5 mm bars (n=25) were prepared from standard-sized milling blocks of each tested material. The bars were subjected to a 3-point flexural test on a 10-mm span with a crosshead speed of 0.5 mm/min. In addition, 42 conventional monolithic crowns (7 per material) were milled. Margin edge quality was observed by means of macrophotography and optical microscopy, providing a qualitative visual assessment and a measurement of existing roughness. The results were analyzed by ANOVA followed by the Tukey HSD test (α=.05). The mean flexural strength of the tested materials ranged from 105 ±9 MPa (VM2) to 219 ±20 MPa (CES). The mean flexural modulus ranged from 8 ±0.25 GPa (CES) to 32 ±1.9 GPa (EMP). The mean modulus of resilience ranged from 0.21 ±0.02 MPa (VM2) to 3.07 ±0.45 MPa (CES). The qualitative assessment of margin edge roughness revealed visible differences among the tested materials, with mean roughness measurements ranging from 60 ±16 μm (CES) to 190 ±15 μm (EMP). The material factor had a significant effect on the mean flexural strength (Pmaterials tested in this study exhibited

  8. CDMS: CAD data set system design description. Revision 1

    International Nuclear Information System (INIS)

    Gray, E.L.

    1994-01-01

    This document is intended to formalize the program design of the CAD Data Set Management System (CDMS) and to be the vehicle to communicate the design to the Engineering, Design Services, and Configuration Management organizations and the WHC IRM Analysts/Programmers. The SDD shows how the software system will be structured to satisfy the requirements identified in the WHC-SD-GN-CSRS-30005 CDMS Software Requirement Specification (SRS). It is a description of the software structure, software components, interfaces, and data that make up the CDMS System. The design descriptions contained within this document will describe in detail the software product that will be developed to assist the aforementioned organizations for the express purpose of managing CAD data sets associated with released drawings, replacing the existing locally developed system and laying the foundation for automating the configuration management

  9. Productivity increase through implementation of CAD/CAE workstation

    Science.gov (United States)

    Bromley, L. K.

    1985-01-01

    The tracking and communication division computer aided design/computer aided engineering system is now operational. The system is utilized in an effort to automate certain tasks that were previously performed manually. These tasks include detailed test configuration diagrams of systems under certification test in the ESTL, floorplan layouts of future planned laboratory reconfigurations, and other graphical documentation of division activities. The significant time savings achieved with this CAD/CAE system are examined: (1) input of drawings and diagrams; (2) editing of initial drawings; (3) accessibility of the data; and (4) added versatility. It is shown that the Applicon CAD/CAE system, with its ease of input and editing, the accessibility of data, and its added versatility, has made more efficient many of the necessary but often time-consuming tasks associated with engineering design and testing.

  10. Application of 3-dimensional CAD modeling system in nuclear plants

    International Nuclear Information System (INIS)

    Suwa, Minoru; Saito, Shunji; Nobuhiro, Minoru

    1990-01-01

    Until now, the preliminary work for mutual components in nuclear plant were readied by using plastic models. Recently with the development of computer graphic techniques, we can display the components on the graphics terminal, better than with use of plastic model and actual plants. The computer model can be handled, both telescopically and microscopically. A computer technique called 3-dimensional CAD modeling system was used as the preliminary work and design system. Through application of this system, database for nuclear plants was completed in arrangement step. The data can be used for piping design, stress analysis, shop production, testing and site construction, in all steps. In addition, the data can be used for various planning works, even after starting operation of plant. This paper describes the outline of the 3-dimensional CAD modeling system. (author)

  11. Percentage Retail Mark-Ups

    OpenAIRE

    Thomas von Ungern-Sternberg

    1999-01-01

    A common assumption in the literature on the double marginalization problem is that the retailer can set his mark-up only in the second stage of the game after the producer has moved. To the extent that the sequence of moves is designed to reflect the relative bargaining power of the two parties it is just as plausible to let the retailer move first. Furthermore, retailers frequently calculate their selling prices by adding a percentage mark-up to their wholesale prices. This allows a retaile...

  12. The microcomputer-based expert system in CAD-PV

    International Nuclear Information System (INIS)

    Wang, Y.; Qin, S.

    1987-01-01

    As a branch of artificial intelligence, expert system has been revealed day after day in more and more engineering scopes since the successful applications of MYCIN in diagnosis and DENDRAL in the molecular structure of organic compounds etc.. But in the design scope of pressure vessel, as we know, only a few papers have so far been published with respect to the expert system. The necessity and feasibility of accompanying CAD-PV with expert system attracted more scholars to engage in. Although many countries, including China, have regularized the design standards or codes for pressure vessel, but of which no one can solve all of the problems concerning the various practical occasions and experiences. In general, the more domain knowledges a design engineer possesses of, the better decision will be made by him. By virtue of the expert system any less experienced engineer could make the optimum decision in design as well as a skilled senior engineer in addition to the application of design code. It is the due significance for developing high level expert system as an intelligence assistant in the plan option of CAD-PV. In this paper we attempt to introduce a specified software JACKPV used in the design procedure of jacketed pressure vessel as an intelligence front in CAD-PV. JACKPV consists of the function of expert system based on the personal computer IBM-PC/XT with the language PASCAL in its program. It was proved that an ordinary CAD software could be effectively improved while equipped with expert system. (orig.)

  13. From CAD to BIM: A New Way to Understand Architecture

    OpenAIRE

    Pérez Sánchez, Juan Carlos; Mora García, Raúl Tomás; Pérez Sánchez, Vicente Raúl; Piedecausa-García, Beatriz

    2017-01-01

    In recent years, and despite the effects of the economic crisis in the building sector, technicians involved in the architectural process had to adapt themselves to many changes, in search of new job opportunities. In this situation, traditional methods imposed by computer-aided design (CAD) in the development of new projects have evolved towards the use of Building Information Modelling (BIM) methodologies, enabling the control of different aspects such as the design, construction and monito...

  14. Converting Geometry from Creo Parametric to BRL-CAD

    Science.gov (United States)

    2017-06-28

    SUPPLEMENTARY NOTES 14. ABSTRACT There exists in vulnerability /lethality analysis an ongoing need to convert target geometries from commercial systems...Contents List of Figures iv 1. Using Commercially Produced Models in Vulnerability /Lethality Analysis 1 2. Installing the Creo to BRL-CAD Converter...distribution is unlimited. 1 1. Using Commercially Produced Models in Vulnerability / Lethality Analysis Vulnerability /lethality (V/L) analysis

  15. CAD And Distributed Manufacturing Solutions for Pellet Boiler Producers

    Directory of Open Access Journals (Sweden)

    Timur Mamut

    2016-12-01

    Full Text Available The paper is summarizing the research activities that had been carried out for defining an appropriate manufacturing concept and the system architecture for a manufacturing plant of pellet boilers. The concept has been validated through the implementation of a solution of computer integrated manufacturing that includes a CAD platform and a CAM facility including laser cutting machines, rolling and welding machines and advanced technologies for assembly, quality control and testing.

  16. The Z-cad dual fluorescent sensor detects dynamic changes between the epithelial and mesenchymal cellular states.

    Science.gov (United States)

    Toneff, M J; Sreekumar, A; Tinnirello, A; Hollander, P Den; Habib, S; Li, S; Ellis, M J; Xin, L; Mani, S A; Rosen, J M

    2016-06-17

    The epithelial to mesenchymal transition (EMT) has been implicated in metastasis and therapy resistance of carcinomas and can endow cancer cells with cancer stem cell (CSC) properties. The ability to detect cancer cells that are undergoing or have completed EMT has typically relied on the expression of cell surface antigens that correlate with an EMT/CSC phenotype. Alternatively these cells may be permanently marked through Cre-mediated recombination or through immunostaining of fixed cells. The EMT process is dynamic, and these existing methods cannot reveal such changes within live cells. The development of fluorescent sensors that mirror the dynamic EMT state by following the expression of bona fide EMT regulators in live cells would provide a valuable new tool for characterizing EMT. In addition, these sensors will allow direct observation of cellular plasticity with respect to the epithelial/mesenchymal state to enable more effective studies of EMT in cancer and development. We generated a lentiviral-based, dual fluorescent reporter system, designated as the Z-cad dual sensor, comprising destabilized green fluorescent protein containing the ZEB1 3' UTR and red fluorescent protein driven by the E-cadherin (CDH1) promoter. Using this sensor, we robustly detected EMT and mesenchymal to epithelial transition (MET) in breast cancer cells by flow cytometry and fluorescence microscopy. Importantly, we observed dynamic changes in cellular populations undergoing MET. Additionally, we used the Z-cad sensor to identify and isolate minor subpopulations of cells displaying mesenchymal properties within a population comprising predominately epithelial-like cells. The Z-cad dual sensor identified cells with CSC-like properties more effectively than either the ZEB1 3' UTR or E-cadherin sensor alone. The Z-cad dual sensor effectively reports the activities of two factors critical in determining the epithelial/mesenchymal state of carcinoma cells. The ability of this stably

  17. Use of Existing CAD Models for Radiation Shielding Analysis

    Science.gov (United States)

    Lee, K. T.; Barzilla, J. E.; Wilson, P.; Davis, A.; Zachman, J.

    2015-01-01

    The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

  18. AutoCAD electrical 2016 for electrical control designers

    CERN Document Server

    Tickoo, Sham

    2016-01-01

    The AutoCAD Electrical 2016 for Electrical Control Designers textbook has been written to assist the engineering students and the practicing designers who are new to AutoCAD Electrical. Using this textbook, the readers can learn the application of basic tools required for creating professional electrical control drawings with the help of AutoCAD Electrical. Keeping in view the varied requirements of the users, this textbook covers a wide range of tools and features such as schematic drawings, Circuit Builder, panel drawings, parametric and nonparametric PLC modules, stand-alone PLC I/O points, ladder diagrams, point-to-point wiring diagrams, report generation, creation of symbols, and so on. This will help the readers to create electrical drawings easily and effectively. Special emphasis has been laid on the introduction of concepts, which have been explained using text and supported with graphical examples. The examples and tutorials used in this book ensure that the users can relate the information provided...

  19. Interoperability of CAD Standards and Robotics in CIME

    DEFF Research Database (Denmark)

    Sørensen, Torben

    The research presented in this dissertation concerns the identification of problems and provision of solutions for increasing the degree of interoperability between CAD, CACSD (Computer Aided Control Systems Design) and CAR (Computer Aided Robotics) in Computer Integrated Manufacturing and Engine......The research presented in this dissertation concerns the identification of problems and provision of solutions for increasing the degree of interoperability between CAD, CACSD (Computer Aided Control Systems Design) and CAR (Computer Aided Robotics) in Computer Integrated Manufacturing......· The development of a STEP based interface for general control system data and functions, especially related to robot motion control for interoperability of CAD, CACSD, and CAR systems for the extension of the inter-system communication capabilities beyond the stage achieved up to now.This interface development...... comprehends the following work:· The definition of the concepts of 'information' and 'information model', and the selection of a proper information modeling methodology within the STEP methodologies.· The elaboration of a general function model of a generic robot motion controller in IDEF0 for interface...

  20. ROCK-CAD - computer aided geological modelling system

    International Nuclear Information System (INIS)

    Saksa, P.

    1995-12-01

    The study discusses surface and solid modelling methods, their use and interfacing with geodata. Application software named ROCK-CAD suitable for geological bedrock modelling has been developed with support from Teollisuuden Voima Oy (TVO). It has been utilized in the Finnish site characterization programme for spent nuclear fuel waste disposal during the 1980s and 1990s. The system is based on the solid modelling technique. It comprises also rich functionality for the particular geological modelling scheme. The ROCK-CAD system provides, among other things, varying graphical vertical and horizontal intersections and perspective illustrations. The specially developed features are the application of the boundary representation modelling method, parametric object generation language and the discipline approach. The ROCK-CAD system has been utilized in modelling spatial distribution of rock types and fracturing structures in TVO's site characterization. The Olkiluoto site at Eurajoki serves as an example case. The study comprises the description of the modelling process, models and illustration examples. The utilization of bedrock models in site characterization, in tentative repository siting as well as in groundwater flow simulation is depicted. The application software has improved the assessment of the sites studied, given a new basis for the documentation of interpretation and modelling work, substituted hand-drawing and enabled digital transfer to numerical analysis. Finally, aspects of presentation graphics in geological modelling are considered. (84 refs., 30 figs., 11 tabs.)

  1. Strategies for the Curation of CAD Engineering Models

    Directory of Open Access Journals (Sweden)

    Manjula Patel

    2009-06-01

    Full Text Available Normal 0 Product Lifecycle Management (PLM has become increasingly important in the engineering community over the last decade or so, due to the globalisation of markets and the rising popularity of products provided as services. It demands the efficient capture, representation, organisation, retrieval and reuse of product data over its entire life. Simultaneously, there is now a much greater reliance on CAD models for communicating designs to manufacturers, builders, maintenance crews and regulators, and for definitively expressing designs. Creating the engineering record digitally, however, presents problems not only for its long-term maintenance and accessibility - due in part to the rapid obsolescence of the hardware, software and file formats involved - but also for recording the evolution of designs, artefacts and products. We examine the curation and preservation requirements in PLM and suggest ways of alleviating the problems of sustaining CAD engineering models through the use of lightweight formats, layered annotation and the collection of Representation Information as defined in the Open Archival Information System (OAIS Reference Model.  We describe two tools which have been specifically developed to aid in the curation of CAD engineering models in the context of PLM: Lightweight Models with Multilayered Annotation (LiMMA and a Registry/Repository of Representation Information for Engineering (RRoRIfE.

  2. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  3. Ovulation leads women to perceive sexy cads as good dads.

    Science.gov (United States)

    Durante, Kristina M; Griskevicius, Vladas; Simpson, Jeffry A; Cantú, Stephanie M; Li, Norman P

    2012-08-01

    Why do some women pursue relationships with men who are attractive, dominant, and charming but who do not want to be in relationships--the prototypical sexy cad? Previous research shows that women have an increased desire for such men when they are ovulating, but it is unclear why ovulating women would think it is wise to pursue men who may be unfaithful and could desert them. Using both college-age and community-based samples, in 3 studies we show that ovulating women perceive charismatic and physically attractive men, but not reliable and nice men, as more committed partners and more devoted future fathers. Ovulating women perceive that sexy cads would be good fathers to their own children but not to the children of other women. This ovulatory-induced perceptual shift is driven by women who experienced early onset of puberty. Taken together, the current research identifies a novel proximate reason why ovulating women pursue relationships with sexy cads, complementing existing research that identifies the ultimate, evolutionary reasons for this behavior.

  4. An approach to biomimetics: the natural CAD/CAM restoration: a clinical report.

    Science.gov (United States)

    Schlichting, Luís Henrique; Schlichting, Kathryn Klemz; Stanley, Kyle; Magne, Michel; Magne, Pascal

    2014-02-01

    Those in the dental field have always pursued the perfect dental material for the treatment of compromised teeth. Gold, amalgam, composite resin, glass ionomer, and porcelain have been used. Tooth-like restorative materials (composite resin and porcelain) combined with an effective hard tissue bond have met the growing demand for esthetic or metal-free restorations in the past 15 to 20 years. However, none of those materials can fully mimic the unique properties of dentin (compliance and crack-stopping behavior) and enamel (wear resistance, function). The aim of this article is to report the restoration of an extensively damaged tooth with a natural restoration obtained by milling an extracted third molar tooth with a computer-aided design and computer-aided manufacturing (CAD/CAM) system. The main benefit of this novel technique is the replacement of lost tissues by actual enamel and dentin, with the potential to recover mechanical, esthetic, and biologic properties. The indication for extracting third molars and premolars because of impaction or for orthodontic reasons makes these posterior teeth readily available. The innovation of the method presented here is the optimal use of the extracted tooth substrate thanks to its positioning technique in the CAD/CAM milling chamber. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  5. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites.

    Science.gov (United States)

    Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik

    2015-03-01

    To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (pCAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (pCAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (pcurry>cress>distilled water) exerted the highest influence on DR (pCAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (pCAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Development of CAD-Based Geometry Processing Module for a Monte Carlo Particle Transport Analysis Code

    International Nuclear Information System (INIS)

    Choi, Sung Hoon; Kwark, Min Su; Shim, Hyung Jin

    2012-01-01

    As The Monte Carlo (MC) particle transport analysis for a complex system such as research reactor, accelerator, and fusion facility may require accurate modeling of the complicated geometry. Its manual modeling by using the text interface of a MC code to define the geometrical objects is tedious, lengthy and error-prone. This problem can be overcome by taking advantage of modeling capability of the computer aided design (CAD) system. There have been two kinds of approaches to develop MC code systems utilizing the CAD data: the external format conversion and the CAD kernel imbedded MC simulation. The first approach includes several interfacing programs such as McCAD, MCAM, GEOMIT etc. which were developed to automatically convert the CAD data into the MCNP geometry input data. This approach makes the most of the existing MC codes without any modifications, but implies latent data inconsistency due to the difference of the geometry modeling system. In the second approach, a MC code utilizes the CAD data for the direct particle tracking or the conversion to an internal data structure of the constructive solid geometry (CSG) and/or boundary representation (B-rep) modeling with help of a CAD kernel. MCNP-BRL and OiNC have demonstrated their capabilities of the CAD-based MC simulations. Recently we have developed a CAD-based geometry processing module for the MC particle simulation by using the OpenCASCADE (OCC) library. In the developed module, CAD data can be used for the particle tracking through primitive CAD surfaces (hereafter the CAD-based tracking) or the internal conversion to the CSG data structure. In this paper, the performances of the text-based model, the CAD-based tracking, and the internal CSG conversion are compared by using an in-house MC code, McSIM, equipped with the developed CAD-based geometry processing module

  7. Prosodic Focus Marking in Bai.

    NARCIS (Netherlands)

    Liu, Zenghui; Chen, A.; Van de Velde, Hans

    2014-01-01

    This study investigates prosodic marking of focus in Bai, a Sino-Tibetan language spoken in the Southwest of China, by adopting a semi-spontaneous experimental approach. Our data show that Bai speakers increase the duration of the focused constituent and reduce the duration of the post-focus

  8. Better marking means cheaper pruning.

    Science.gov (United States)

    Kenneth R. Eversole

    1953-01-01

    Careful selection of trees to be pruned can make the difference between profit and loss on the pruning investment, especially in stands where no thinning is contemplated. Expert marking is required to make sure that the pruned trees will grow rapidly. The most important variable influencing the cost of clear wood produced by pruning is growth rate. For example, at 3...

  9. Peningkatan Prestasi Belajar CAD Mahasiswa Teknik Otomotif Non-Reguler FT UNY melalui Pembuatan “Pohon Kata” Perintah dalam Program AutoCAD

    Directory of Open Access Journals (Sweden)

    Martubi Martubi

    2010-05-01

    Full Text Available Penelitian ini bertujuan meningkatkan prestasi belajar mata kuliah Computer Aided Design (CAD mahasiswa prodi Teknik Otomotif Non-Reguler yang dinyatakan dalam bentuk rerata nilai akhir semester yang berasal dari komponen nilai tugas harian, nilai ujian tengah semester dan nilai ujian akhir semester. Penelitian quasi-eksperimen ini terdiri dari tahapan penelitian diawali dengan penyusunan materi pembelajaran sejumlah pokok bahasan tertentu dalam satu job sheet (lembar kerja, dilanjutkan dengan pembuatan bantuan “Pohon Kata” perintah dalam Auto CAD kepada kelas eksperimen yang ditentukan secara random dari dua kelas peserta kuliah Auto CAD pada Semester Genap 2008/2009. Kedua kelas diamati prestasinya, baik kecepatan penyelesaiannya maupun kualitas kebenaran gambarnya. Prestasi belajar kedua kelas juga diukur melalui pemberian ujian tengah semester dan ujian akhir semester. Setelah data prestasi kedua kelas terkumpul dilanjutkan dengan analisis statistik melalui uji beda (t-test setelah sebelumnya dilakukan uji persyaratan analisis yang ternyata dapat dipenuhi. Hasil penelitian ini disimpulkan bahwa: prestasi belajar CAD mahasiswa pada kelas yang diberi perlakuan strategi pembelajaran menggunakan “Pohon Kata” perintah dalam Program Auto CAD lebih baik dibanding prestasi belajar CAD mahasiswa pada kelas yang tidak diberi perlakuan (75,41>70,89, dengan demikian pembelajaran CAD menggunakan media “Pohon Kata” perintah dalam Program Auto CAD dapat meningkatkan prestasi belajar mahasiswa Teknik Otomotif Program Non-Reguler.

  10. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    International Nuclear Information System (INIS)

    Weinhorst, Bastian; Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng; Wilson, Paul

    2015-01-01

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  11. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Wilson, Paul [University of Wisconsin-Madison, Computational Nuclear Engineering Research Group, Madison, WI (United States)

    2015-10-15

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  12. Are unnecessary follow-up procedures induced by computer-aided diagnosis (CAD) in mammography? Comparison of mammographic diagnosis with and without use of CAD

    International Nuclear Information System (INIS)

    Marx, Christiane; Malich, Ansgar; Facius, Mirjam; Grebenstein, Uta; Sauner, Dieter; Pfleiderer, Stefan O.R.; Kaiser, Werner A.

    2004-01-01

    Objective: To evaluate the rate of unnecessary follow-up procedures recommended by radiologists using a CAD-system. Materials and methods: 185 patients (740 images) were consecutively selected from three groups (36 histologically proven cancers=group 1; 49 histologically proven benign lesions=group 2 and 100 screening cases (4 years-follow up=group 3). Mammograms were evaluated by a CAD system (Second Look [reg] , CADx, Canada). Five blinded radiologists assessed the images without/with CAD outputs. Diagnostic decisions were ranked from surely benign to surely malignant according to BIRADS classification, follow-up procedures were recommended for each observed lesion (a, screening; b, short interval follow-up examination in 6 months; c, pathologic clarification). Results: CAD-system detected 32/36 cancers (88.9%) (FP-rate: 1.04 massmarks and 0.27 calcmarks/image). The following values were reached by all observers without/with CAD in the mean: Sensitivity 80.6/80.0%, specificity 83.2/86.4%, PPV 53.1/58.1%, and NPV 94.6/94.7%. Observers described a similar number of additional lesions without/with the use of CAD (325/326). Whereas the number of unnecessary short-time follow up recommendations increased in all case-subgroups with CAD: 40.8/42.9% (group 1), 35.6/38.1% (group 2), 44.7/46.8% (group 3), respectively, the number of recommended biopsies decreased in all subgroups: group 1: 34.7/27.1%; group 2: 47.4/41.5%, group 3: 33.3/22.0%, respectively. Conclusion: In this rather small population additional usage of CAD led to a lower rate of unnecessary biopsies. The observed decrease of recommended unnecessary biopsies due to the usage of CAD in the screening group suggests a potential financial benefit by using CAD as diagnostic aid

  13. Automated road marking recognition system

    Science.gov (United States)

    Ziyatdinov, R. R.; Shigabiev, R. R.; Talipov, D. N.

    2017-09-01

    Development of the automated road marking recognition systems in existing and future vehicles control systems is an urgent task. One way to implement such systems is the use of neural networks. To test the possibility of using neural network software has been developed with the use of a single-layer perceptron. The resulting system based on neural network has successfully coped with the task both when driving in the daytime and at night.

  14. [Werkgartner's muzzle imprint mark--a literature study].

    Science.gov (United States)

    Geserick, Gunther; Vendura, Klaus; Wirth, Ingo

    2009-01-01

    Since Werkgartner described and correctly interpreted the muzzle imprint mark around the gunshot entrance wound in 1922, this finding has been generally accepted as a sign of a contact shot. In further studies, it could finally be clarified that the muzzle imprint mark is caused by the expansive power of the powder gases with pressure on and abrasion of the skin at the muzzle (weapon imprint). Its shape depends on the firearm, the ammunition and the anatomical conditions, but does not require a bullet. Examinations under a magnifying glass microscope and histological investigations can complete the macroscopic findings. Occasionally, the muzzle imprint mark requires a certain "drying period" in order to become clearly visible. In rare cases, muzzle imprint marks also form on textiles perforated by the projectile. Characteristically shaped muzzled imprint marks can provide clues to the type of the firearm and its position at the time of discharge.

  15. Mark Twain: inocente ou pecador? = Mark Twain: innocent or sinner?

    Directory of Open Access Journals (Sweden)

    Heloisa Helou Doca

    2009-01-01

    Full Text Available A leitura cuidadosa do texto do “Tratado de Paris”, em 1900, leva Mark Twain a concluir que a intenção política norte-americana era, claramente, a de subjugação. Declara-se, abertamente, antiimperialista, nesse momento, apesar das inúmeras críticasrecebidas por antagonistas políticos que defendiam o establishment dos Estados Unidos. Após viajar para a Europa e Oriente, em 1867, como correspondente do jornal Daily Alta Califórnia, Mark Twain publica, em 1869, seu relato de viagem, The Innocents Abroad or TheNew Pilgrim’s Progress. Nosso estudo demonstra que o autor, apesar das diversas máscaras usadas em seus relatos, narra histórias, culturas e tradições, tanto da Europa quanto do Oriente, já com os olhos bem abertos pelo viés antiimperialista. Faz uso da paródia, sátira, ironia e humor para dessacralizar impérios, monarcas e a Igreja que subjugavam os mais fracos, iluminando, desde então, os estudos sobre culturas. Nosso estudo, outrossim, faz uma reflexão sobre cultura, tradição e o olhar do viajante, justificando o “olhar inocente” do narrador em seu relato.After carefully reading the Treaty of Paris in 1900, Mark Twain concluded that the goal of U.S. policy was clearly one ofsubjugation. He openly declared himself an anti-imperialist at that time, in spite of the numerous criticisms he received from political opponents who supported the United States status quo. After traveling to Europe and the East in 1867 as a correspondent for The DailyAlta California newspaper, Mark Twain published his travel report, The Innocents Abroad or The New Pilgrim’s Progress in 1869. Our study demonstrates that the author, in spite of using different guises in his reports, narrated histories, cultures and traditions – from both Europe and the East – with a viewpoint already imbued by his anti-imperialistic ideals. Twain made use of parody, satire, irony and humor within his texts in order to desecrate empires,monarchs and

  16. CAD/CAM and scientific data management at Dassault

    Science.gov (United States)

    Bohn, P.

    1984-01-01

    The history of CAD/CAM and scientific data management at Dassault are presented. Emphasis is put on the targets of the now commercially available software CATIA. The links with scientific computations such as aerodynamics and structural analysis are presented. Comments are made on the principles followed within the company. The consequences of the approximative nature of scientific data are examined. Consequence of the new history function is mainly its protection against copy or alteration. Future plans at Dassault for scientific data appear to be in opposite directions compared to some general tendencies.

  17. TinkerCell: modular CAD tool for synthetic biology

    Science.gov (United States)

    Chandran, Deepak; Bergmann, Frank T; Sauro, Herbert M

    2009-01-01

    Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD) is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API). TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at . Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled and analyzed computationally. TinkerCell can readily

  18. Automated knowledge base development from CAD/CAE databases

    Science.gov (United States)

    Wright, R. Glenn; Blanchard, Mary

    1988-01-01

    Knowledge base development requires a substantial investment in time, money, and resources in order to capture the knowledge and information necessary for anything other than trivial applications. This paper addresses a means to integrate the design and knowledge base development process through automated knowledge base development from CAD/CAE databases and files. Benefits of this approach include the development of a more efficient means of knowledge engineering, resulting in the timely creation of large knowledge based systems that are inherently free of error.

  19. TinkerCell: modular CAD tool for synthetic biology

    Directory of Open Access Journals (Sweden)

    Bergmann Frank T

    2009-10-01

    Full Text Available Abstract Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API. TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at http://www.tinkercell.com. Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled

  20. AutoCAD Civil 3D 2014 essentials

    CERN Document Server

    Chappell, Eric

    2013-01-01

    Quickly learn essential Civil 3D tools and techniques Get a thorough introduction to AutoCAD Civil 3D, the industry-leading engineering software used to design roads, highways, subdivisions, drainage and sewer systems, and more. This Autodesk Official Press book is a unique learning resource that features concise, straightforward explanations and real-world, hands-on exercises and tutorials. With compelling full-color screenshots and approachable exercises that demonstrate core features and functions, the book helps you gain understanding and confidence as you master this premiere

  1. How successful is secondary prevention for coronary artery disease (CAD) in the real world

    International Nuclear Information System (INIS)

    Rauf, M.A.; Khan, N.; Khan, N.; Khan, I.; Hafizullah, M.; Mahmood, N.

    2012-01-01

    Objective: To document the effects of secondary prevention on different risk factors in the real world situation. Methodology: It was a cross sectional comparative study carried out at a referral cardiac clinic in Peshawar from January 2010 to December 2010. Study subjects presenting with at least 6 months follow up were included from different parts of Khyber Pukhtunkhawa. All patients with positive history or objective evidence of CAD were enrolled. Study subjects were divided in two groups based on the fact that either taking or had stopped medication for the duration of the study period. Study variables were levels of lipids, glucose, blood pressure (BP), smoking and obesity. Results: A total of 843 patients were included in the study. Males were 70.4 % (593). Mean age was 58.74 +- 10.6 years. Patients taking regular medicine were 69.03% while 30.97% had stopped their medicine for at least three months. Diabetics, hypertensive and positive family history for CAD were 33.4%, 50.25% and 24% respectively. When compared to patient who had stopped medicine, mean systolic BP (p= 0.014), diastolic BP (p= 0.05), mean Cholesterol (p=0.000), mean LDL (p=0.000), mean HDL (p=0.000) and HbA1c% (p=0.049), was well controlled in patients who were taking medicine regularly. Mean BMI (p=0.786), triglycerides and smoking (p=0.761) had no significant difference between the two groups. Conclusion: Blood pressure, serum cholesterol, LDL, HDL, as well as HbA1c% were reduced with little effect on serum TGs, BMI and smoking in those who were taking medicine regularly compared to those who had stopped. (author)

  2. Innovation problems of new technologies - the introduction of CAD to mechnical engineering

    Energy Technology Data Exchange (ETDEWEB)

    Riehm, U; Rader, M

    1982-01-01

    The introduction of CAD (computer aided design) is accompanied by uncertainties in the estimation of the needs, the effectivity and the consequence of the application of CAD. Similar uncertainties have also been observed in the past during the introduction of NC-tooling machines. These problems can be solved by a parallel scientific evaluation of the experience made. This is the main purpose of a social science study accomaniing the introduction of CAD, which is presented here.

  3. Introduction of effect and consideration of the introduction of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-12-01

    This reports introduction of effect and consideration of the introduction of computer-aided design and computer aided manufacturing system. It includes outline of CAD/CAM system like definition, classification, system kinds, and development process of CAD/CAM system, technology, market trend development prospect, and value on introduction of this system, and current application of CAD/CAM system in major application area, development countries and Korea.

  4. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006 - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collabora- tion avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  5. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006

    - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium, Bât 593 Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collaboration avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  6. Recent results for Mark III

    International Nuclear Information System (INIS)

    Brient, J.C.

    1987-12-01

    This paper presents recent results from the Mark III detector at SPEAR, in the open charm sector. The first topic discussed is the reanalysis of the direct measurement of the D hadronic branching fractions, where a detailed study has been made of the Cabibbo suppressed and multi-π 0 's D decays backgrounds in the double tag sample. Next, the Dalitz plot analysis of the D decays to Kππ is presented, leading to the relative fractions of three-body versus pseudoscalarvector decays. 7 refs., 5 figs

  7. The Mark III vertex chamber

    International Nuclear Information System (INIS)

    Adler, J.; Bolton, T.; Bunnell, K.

    1987-07-01

    The design and construction of the new Mark III vertex chamber is described. Initial tests with cosmic rays prove the ability of track reconstruction and yield triplet resolutions below 50 μm at 3 atm using argon/ethane (50:50). Also performed are studies using a prototype of a pressurized wire vertex chamber with 8 mm diameter straw geometry. Spatial resolution of 35mm was obtained using dimethyl ether (DME) at 1 atm and 30 μm using argon/ethane (50/50 mixture) at 4 atm. Preliminary studies indicate the DME to adversely affect such materials as aluminized Mylar and Delrin

  8. 46 CFR 185.602 - Hull markings.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Hull markings. 185.602 Section 185.602 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Markings Required § 185.602 Hull markings. (a) Each vessel must be marked as required by part 67...

  9. 27 CFR 28.193 - Export marks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Export marks. 28.193... Drawback Filing of Notice and Removal § 28.193 Export marks. In addition to the marks and brands required... chapter, the exporter shall mark the word “Export” on the Government side of each case or Government head...

  10. 27 CFR 28.103 - Export marks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Export marks. 28.103... Manufacturing Bonded Warehouse § 28.103 Export marks. (a) General. In addition to the marks and brands required... provisions of part 19 of this chapter, the proprietor shall mark the word “Export” on the Government side of...

  11. 27 CFR 28.144 - Export marks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Export marks. 28.144... § 28.144 Export marks. (a) General Requirement. In addition to the marks and brands required to be... brewer shall mark the word “Export” on each container or case of beer, or the words “Beer concentrate for...

  12. 27 CFR 28.154 - Export marks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Export marks. 28.154..., for Exportation or Transfer to a Foreign-Trade Zone § 28.154 Export marks. In addition to the marks... provisions of part 19 of this chapter, the proprietor shall mark the word “Export” on the Government side of...

  13. CAD-based Monte Carlo automatic modeling method based on primitive solid

    International Nuclear Information System (INIS)

    Wang, Dong; Song, Jing; Yu, Shengpeng; Long, Pengcheng; Wang, Yongliang

    2016-01-01

    Highlights: • We develop a method which bi-convert between CAD model and primitive solid. • This method was improved from convert method between CAD model and half space. • This method was test by ITER model and validated the correctness and efficiency. • This method was integrated in SuperMC which could model for SuperMC and Geant4. - Abstract: Monte Carlo method has been widely used in nuclear design and analysis, where geometries are described with primitive solids. However, it is time consuming and error prone to describe a primitive solid geometry, especially for a complicated model. To reuse the abundant existed CAD models and conveniently model with CAD modeling tools, an automatic modeling method for accurate prompt modeling between CAD model and primitive solid is needed. An automatic modeling method for Monte Carlo geometry described by primitive solid was developed which could bi-convert between CAD model and Monte Carlo geometry represented by primitive solids. While converting from CAD model to primitive solid model, the CAD model was decomposed into several convex solid sets, and then corresponding primitive solids were generated and exported. While converting from primitive solid model to the CAD model, the basic primitive solids were created and related operation was done. This method was integrated in the SuperMC and was benchmarked with ITER benchmark model. The correctness and efficiency of this method were demonstrated.

  14. Association of rs662799 in APOA5 with CAD in Chinese Han population.

    Science.gov (United States)

    Chen, Hua; Ding, Shifang; Zhou, Mi; Wu, Xiayin; Liu, Xi; Wu, Yun; Liu, Dechao

    2018-01-08

    CAD (Coronary Artery Disease) is a complex disease that influenced by various environmental and genetic factors. Previous studies have found many single nucleotide polymorphisms (SNPs) associated with the risk of CAD occurrence. However, the results are inconsistent. In this study, we aim to investigate genetic etiology in Chinese Han population by analysis of 7 SNPs in lipid metabolism pathway that previously has been reported to be associated with CAD. A total of 631 samples were used in this study, including 435 CAD cases and 196 normal healthy controls. SNP genotyping were conducted via multiplex PCR amplifying followed by NGS (next-generation sequencing). Rs662799 in APOA5 (Apolipoprotein A5) gene was associated with CAD in Chinese Han population (Odds-ratio = 1.374, P-value = 0.03). No significant association was observed between the rest of SNPs and CAD. Stratified association analysis revealed rs5882 was associated with CAD in non-hypertension group (Odds-ratio = 1.593, P-value = 0.023). Rs1800588 was associated with CAD in smoking group (Odds-ratio = 1.603, P-value = 0.035). The minor allele of rs662799 was the risk factor of CAD occurrences in Chinese Han population.

  15. Up and running with AutoCAD 2013 2D and 3D drawing and modeling

    CERN Document Server

    Gindis, Elliot

    2012-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains support

  16. BombCAD - A new tool for bomb defense in nuclear facilities

    International Nuclear Information System (INIS)

    Massa, D.J.; Howard, J.W.; Sturm, S.R.

    1988-01-01

    This paper describes a new tool for analysis of the specific vulnerability of diverse facilites to bomb attack and for computer-aided-design (CAD) of siting, screening and hardening/softening aspects of comprehensive bomb defense programs. BombCAD combines the extensive architectural and engineering data base and graphics capabilities of modern architectural CAD systems with the bomb effects computational capability of the ''SECUREPLAN'' BOMB UTILITY. BombCAD permits architects/engineers, security professionals and facility managers to analytically estimate and graphically display facility vulnerability and changes (reductions) in vulnerability which result from the adoption of various bomb defense measures

  17. Deactivation of the E. coli pH stress sensor CadC by cadaverine.

    Science.gov (United States)

    Haneburger, Ina; Fritz, Georg; Jurkschat, Nicole; Tetsch, Larissa; Eichinger, Andreas; Skerra, Arne; Gerland, Ulrich; Jung, Kirsten

    2012-11-23

    At acidic pH and in the presence of lysine, the pH sensor CadC activates transcription of the cadBA operon encoding the lysine/cadaverine antiporter CadB and the lysine decarboxylase CadA. In effect, these proteins contribute to acid stress adaptation in Escherichia coli. cadBA expression is feedback inhibited by cadaverine, and a cadaverine binding site is predicted within the central cavity of the periplasmic domain of CadC on the basis of its crystallographic analysis. Our present study demonstrates that this site only partially accounts for the cadaverine response in vivo. Instead, evidence for a second, pivotal binding site was collected, which overlaps with the pH-responsive patch of amino acids located at the dimer interface of the periplasmic domain. The temporal response of the E. coli Cad module upon acid shock was measured and modeled for two CadC variants with mutated cadaverine binding sites. These studies supported a cascade-like binding and deactivation model for the CadC dimer: binding of cadaverine within the pair of central cavities triggers a conformational transition that exposes two further binding sites at the dimer interface, and the occupation of those stabilizes the inactive conformation. Altogether, these data represent a striking example for the deactivation of a pH sensor. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Preparation of CAD infrastructure for ITER procurement packages allocated to Korea

    International Nuclear Information System (INIS)

    Kim, G.H.; Hwang, H.S.; Choi, J.H.; Lee, H.G.; Thomas, E.; Redon, F.; Wilhelm, B.

    2013-01-01

    Highlights: ► It is necessary to use the same CAD platform between project partners for efficient design collaboration. ► Several unexpected problems were found during preparation of the CAD infrastructure. ► The problems have resulted in a waste of time and cost. ► The approach using the same configurations is effective to avoid IT-related problems. ► The design activities are steadily being performed on the prepared ITER CAD platform. -- Abstract: It is necessary to use the same CAD platform for standardization and efficient design collaboration between project partners. ITER has selected CATIA with ENOVIA as the primary CAD and integration tool. During the preparation of the CAD infrastructure, there were several difficulties with respect to information technology (IT). ITER design is classified as mechanical and plant. The procurement arrangement is divided into three types; functional specification, detailed design, and build to print. Therefore, it is important to prepare the suitable prerequisites according to the design type, and to comply with CAD methodologies to avoid trial and error. This paper presents how to overcome the difficulties and how to perform the CAD activities for ITER Korea procurement packages including important matters on a CAD infrastructure in a big project

  19. Up and Running with AutoCAD 2011 2D and 3D Drawing and Modeling

    CERN Document Server

    Gindis, Elliot

    2010-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains supporting graphics (screen shot

  20. Up and Running with AutoCAD 2012 2D and 3D Drawing and Modeling

    CERN Document Server

    Gindis, Elliot

    2011-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains supporting graphics (screen shot

  1. Integrating CAD modules in a PACS environment using a wide computing infrastructure.

    Science.gov (United States)

    Suárez-Cuenca, Jorge J; Tilve, Amara; López, Ricardo; Ferro, Gonzalo; Quiles, Javier; Souto, Miguel

    2017-04-01

    The aim of this paper is to describe a project designed to achieve a total integration of different CAD algorithms into the PACS environment by using a wide computing infrastructure. The aim is to build a system for the entire region of Galicia, Spain, to make CAD accessible to multiple hospitals by employing different PACSs and clinical workstations. The new CAD model seeks to connect different devices (CAD systems, acquisition modalities, workstations and PACS) by means of networking based on a platform that will offer different CAD services. This paper describes some aspects related to the health services of the region where the project was developed, CAD algorithms that were either employed or selected for inclusion in the project, and several technical aspects and results. We have built a standard-based platform with which users can request a CAD service and receive the results in their local PACS. The process runs through a web interface that allows sending data to the different CAD services. A DICOM SR object is received with the results of the algorithms stored inside the original study in the proper folder with the original images. As a result, a homogeneous service to the different hospitals of the region will be offered. End users will benefit from a homogeneous workflow and a standardised integration model to request and obtain results from CAD systems in any modality, not dependant on commercial integration models. This new solution will foster the deployment of these technologies in the entire region of Galicia.

  2. Implementasi Penggunaan Aplikasi AutoCAD dalam Meningkatkan Kompetensi Dasar Menggambar teknik bagi Masyarakat

    Directory of Open Access Journals (Sweden)

    Risma Dwi Atmajayani

    2018-05-01

    Full Text Available Dengan berkembangnya teknologi, maka gambarpun ikut mengalami kemajuan dalam penggunaannya. Dengan kecanggihan dan kemajuan teknologi dapat melahirkan suatu cara menggambar dengan media komputer. Teknologi dapat membantu mempercepat menyelesaikan suatu pekerjaan, tidak terkecuali aplikasi CAD (Computer Aided Design. Program yang sering digunakan untuk pengajaran CAD adalah AutoCAD yang merupakan sebuah aplikasi (software yang digunakan untuk menggambar, mendesain gambar, menguji material dimana program tersebut mempunyai kemudahan dan keunggulan untuk membuat gambar secara tepat dan akurat. Berdasarkan temuan dilapangan yang didasari tinjauan langsung, didapatkan informasi bahwa materi AutoCAD yang diperoleh dari jenjang sebelumnya masih banyak yang jauh dari kondisi ideal. Materi AutoCAD yang didapatkan masih banyak tentang teori sedikit praktek, perangkat hardware yang terbatas sampai pada ketersediaan sumber daya manusia yang kurang adalah permasalahan umum yang terjadi. Adapun tujuan yang ingin dicapai adalah (1 Meningkatkan mutu peserta pelatihan melalui workshop pemanfaatan aplikasi AutoCAD (2 Meningkatkan ketrampilan peserta pelatihan dengan membuat suatu proyek desain gambar bangun berbasis aplikasi AutoCAD. Manfaat kegiatan pelatihan adalah: (1 Peserta pelatihan dapat meningkatkan pemahaman tentang program AutoCAD; (2 Peserta pelatihan dapat menyalurkan pengetahuan dan ketrampilan yang didapatkan nantinya kepada yang membutuhkan dan terutama akan sangat membantu para calon civil engineer dalam menyelesaikan pekerjaan yang berkaitan dengan desain rancang bangun; (3 Peserta pelatihan dapat mendesain gambar menggunakan program AutoCAD.

  3. Up and running with AutoCAD 2014 2D and 3D drawing and modeling

    CERN Document Server

    Gindis, Elliot

    2013-01-01

    Get ""Up and Running"" with AutoCAD using Gindis's combination of step-by-step instruction, examples, and insightful explanations. The emphasis from the beginning is on core concepts and practical application of AutoCAD in architecture, engineering and design. Equally useful in instructor-led classroom training, self-study, or as a professional reference, the book is written with the user in mind by a long-time AutoCAD professional and instructor based on what works in the industry and the classroom. Strips away complexities, both real and perceived, and reduces AutoCAD t

  4. Interview with Professor Mark Wilcox.

    Science.gov (United States)

    Wilcox, Mark

    2016-08-01

    Mark Wilcox speaks to Georgia Patey, Commissioning Editor: Professor Mark Wilcox is a Consultant Microbiologist and Head of Microbiology at the Leeds Teaching Hospitals (Leeds, UK), the Professor of Medical Microbiology at the University of Leeds (Leeds, UK), and is the Lead on Clostridium difficile and the Head of the UK C. difficile Reference Laboratory for Public Health England (PHE). He was the Director of Infection Prevention (4 years), Infection Control Doctor (8 years) and Clinical Director of Pathology (6 years) at the Leeds Teaching Hospitals. He is Chair of PHE's Rapid Review Panel (reviews utility of infection prevention and control products for National Health Service), Deputy Chair of the UK Department of Health's Antimicrobial Resistance and Healthcare Associated Infection Committee and a member of PHE's HCAI/AR Programme Board. He is a member of UK/European/US working groups on C. difficile infection. He has provided clinical advice as part of the FDA/EMA submissions for the approval of multiple novel antimicrobial agents. He heads a healthcare-associated infection research team at University of Leeds, comprising approximately 30 doctors, scientists and nurses; projects include multiple aspects of C. difficile infection, diagnostics, antimicrobial resistance and the clinical development of new antimicrobial agents. He has authored more than 400 publications, and is the coeditor of Antimicrobial Chemotherapy (5th/6th/7th Editions, 15 December 2007).

  5. Tools for building Breast Cancer CAD methods; Herramientas para elaborar metodos de CAD del cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Herrero, G.; Franco-Valiente, J. M.; Suarez-Ortega, C.; Rubio del Solar, M.; Ramos-Pollam, R.; Guevara-Lopez, M. A.; Gonzalez de Posada, N.; Ramos, I.; Loureiro, J.

    2011-07-01

    This paper describes the main results of the collaboration currently ongoing between CETA-CIEMAT and the Faculty of Engineering at the University of Porto. It introduces the Mammography image Workstation for Analysis and Diagnosis (MIWAD) and the data analysis processes through which Grid infrastructures are used to develop Breast Cancer Computer-Aided Diagnosis (CAD) methods.MIWAD is a novel integrated software framework that integrates a specialized graphical user interface combining digital image processing, pattern recognition and artificial intelligence techniques. This paper describes its successful application in a pilot experience, on the first Portuguese Breast Cancer Digital Repository. (Author)

  6. Structure of ganglioside with CAD blood group antigen activity

    International Nuclear Information System (INIS)

    Gillard, B.K.; Blanchard, D.; Cartron, J.P.; van Kuik, G.A.; Vliegenthart, J.F.G.; Marcus, D.M.

    1986-01-01

    The novel erythrocyte ganglioside which carries the blood group Cad determinant has been isolated, and its structure has been determined. The ganglioside contained Glu:Gal:GalNAc:GlcNAc in a molar ratio of 1.00:1.94:0.93:0.95. The ganglioside binds Helix pomatia lectin and its chromatographic mobility is similar to G/sub D3/. After treatment with β-hexosaminidase (human placenta HexA) the product migrated with sialosylparagloboside (SPG), no longer binds Helix lectin, and binds a human anti-SPG antibody. Treatment of this material with neuraminidase (V. cholera) yielded a product with the mobility of paragloboside that bound monoclonal antibody 1B2. NMR analysis revealed that the terminal GalNAc is linked β1-4 to Gal, and confirms the structure proposed previously: GalNAcβ1-4(NeuAcα2-3)Galβ1-4GlcNAcβ1-3Galβ1-4Glc-Cer. This structure is consistent with the previous demonstration that a compound with the same chromatographic mobility as the Cad ganglioside could be synthesized by enzymatic transfer of GalNAc to sialosylparagloboside

  7. Refining a brief decision aid in stable CAD: cognitive interviews.

    Science.gov (United States)

    Kelly-Blake, Karen; Clark, Stacie; Dontje, Katherine; Olomu, Adesuwa; Henry, Rebecca C; Rovner, David R; Rothert, Marilyn L; Holmes-Rovner, Margaret

    2014-02-13

    We describe the results of cognitive interviews to refine the "Making Choices©" Decision Aid (DA) for shared decision-making (SDM) about stress testing in patients with stable coronary artery disease (CAD). We conducted a systematic development process to design a DA consistent with International Patient Decision Aid Standards (IPDAS) focused on Alpha testing criteria. Cognitive interviews were conducted with ten stable CAD patients using the "think aloud" interview technique to assess the clarity, usefulness, and design of each page of the DA. Participants identified three main messages: 1) patients have multiple options based on stress tests and they should be discussed with a physician, 2) take care of yourself, 3) the stress test is the gold standard for determining the severity of your heart disease. Revisions corrected the inaccurate assumption of item number three. Cognitive interviews proved critical for engaging patients in the development process and highlighted the necessity of clear message development and use of design principles that make decision materials easy to read and easy to use. Cognitive interviews appear to contribute critical information from the patient perspective to the overall systematic development process for designing decision aids.

  8. Engineering applications using CAD based application programming interface

    Directory of Open Access Journals (Sweden)

    Tzotzis Anastasios

    2017-01-01

    Full Text Available Automating the design process of a product or a system can provide engineers and designers with many benefits. As such, repeatable tasks that are time consuming can be handled automatically and with minimal human attention. This is achieved by using the API (Application Programmable Interface of CAD systems in order to create macros or even develop software applications. The present paper deals with an application that has been developed with the API of a general purposes CAD system. This application automates the design process of a standard pneumatic double acting cylinder based on the appropriate inserted parameters (ISO 15552.The design process begins with the creation of a series of components developed as solids, and extends to the extraction of basic attributes and properties from the complete mechanical assembly. Finally, the assembled models and the extracted data can be used to further study the design of the pneumatic double acting cylinder. It is expected in the future to expand the features of the presented application in order to automate the design process of other related mechanical systems.

  9. Is the application of CAD useful for radiologists for passing the official tests required for outpatient breast imaging?

    International Nuclear Information System (INIS)

    Malich, A.; Beier, A.; Gorna, R.; Bank, P.

    2007-01-01

    Purpose: to analyze whether currently available CAD systems meet the diagnostic requirements for passing screening tests (first reader CAD) and to analyze whether the additional usage of CAD systems provides significant support for the diagnosing radiologist on the basis of official screening test cases (second reading by CAD). Material and methods: 200 images of 100 mammographies of 50 patients of an official screening test case collection were analyzed double-blind with and without CAD printouts (iCAD, U.S.A.) by three radiologists: one experienced in breast analysis and CAD application, one experienced in mammography analysis but inexperienced in CAD usage, one with minimal experience with breast analysis and CAD application. All radiologists measured the largest diameter of any malignant mass. The mean value of these calculations was correlated to the largest diameter given by CAD prompts. Results: the mean sensitivity and specificity increased slightly as a result of the additional usage of CAD (1 and 0.6%, resp.). Both values are not statistically significant. The highest effect was measured for the radiologist with CAD experience, while no effect was measured for the inexperienced radiologist. CAD met the sensitivity requirements but not the specificity criteria (96 and 20.3%, resp.). The sizes given by CAD prompts corresponded significantly with the real sizes (r = 0.45, p < 0.05). (orig.)

  10. Bonding to CAD-CAM Composites: An Interfacial Fracture Toughness Approach.

    Science.gov (United States)

    Eldafrawy, M; Ebroin, M G; Gailly, P A; Nguyen, J-F; Sadoun, M J; Mainjot, A K

    2018-01-01

    The objective of this study was to evaluate the interfacial fracture toughness (IFT) of composite cement with dispersed filler (DF) versus polymer-infiltrated ceramic network (PICN) computer-aided design and computer-aided manufacturing (CAD-CAM) composite blocks after 2 different surface pretreatments using the notchless triangular prism (NTP) test. Two DFs (Cerasmart [CRT] and Lava Ultimate [LVA]), 2 PICNs (Enamic [ENA] and experimental PICN [EXP]), and e.max CAD lithium disilicate glass-ceramic (EMX, control) prism samples were bonded to their counterparts with Variolink Esthetic DC composite cement after either hydrofluoric acid etching (HF) or gritblasting (GR). Both procedures were followed by silanization. All samples ( n = 30 per group) were thermocycled (10,000 cycles) and tested for their IFT in a water bath at 36°C. Moreover, representative samples from each group were subjected to a developed interfacial area ratio (Sdr) measurement by profilometry and scanning electron microscopy (SEM) characterization. EXP-HF gave the highest IFT (1.85 ± 0.39 MPa·m 1/2 ), followed by EMX-HF and ENA-HF, while CRT-HF gave the lowest (0.15 ± 0.22 MPa·m 1/2 ). PICNs gave significantly better results with HF, and DF showed better results with GR. A 2-way analysis of variance indicated that there were significantly higher IFT and Sdr for PICNs than for DF. A positive correlation ( r² = 0.872) was found between IFT and Sdr. SEM characterization showed the specific microstructure of the surface of etched PICNs, indicating the presence of a retentive polymer-based honeycomb structure. Etching of the typical double-network microstructure of PICNs causes an important increase in the Sdr and IFT, while DF should be gritblasted. DF exhibited significantly lower Sdr and IFT values than PICNs. The present results show the important influence of the material class and surface texture, and consequently the micromechanical bond, on the adhesive interface performance of CAD

  11. An 8-year evaluation of sintered ceramic and glass ceramic inlays processed by the Cerec CAD/CAM system

    DEFF Research Database (Denmark)

    Pallesen, U.; Dijken van, J.W.V.

    2000-01-01

    The purpose of this study was to evaluate Cerec CAD/CAM inlays processed of two industrially made machinable ceramics during an 8-yr follow-up period. Each of 16 patients received two similar ceramic inlays. Half the number of the inlays were made of a feldspathic (Vita Mark II) and the other...... of a glass ceramic (Dicor MGC) block. The inlays were luted with a dual resin composite and evaluated clinically using modified USPHS criteria at baseline, 8 months, 2, 3, 5, 6 and 8 yr, and indirectly using models. At baseline, 84% of the inlays were estimated as optimal and 16% as acceptable. Postoperative...... sensitivity was reported by one patient for 8 months. Of the 32 inlays evaluated during the 8 yr, 3 failed due to fracture of the material. No secondary caries was found adjacent to the inlays. No significant differences in the clinical performance were found between inlays made of the two ceramics. It can...

  12. Depressed mood, positive affect, and heart rate variability in patients with suspected coronary artery disease.

    Science.gov (United States)

    Bhattacharyya, Mimi R; Whitehead, Daisy L; Rakhit, Roby; Steptoe, Andrew

    2008-11-01

    To test associations between heart rate variability (HRV), depressed mood, and positive affect in patients with suspected coronary artery disease (CAD). Depression is associated with impaired HRV post acute cardiac events, but evidence in patients with stable coronary artery disease (CAD) is inconsistent. Seventy-six patients (52 men, 24 women; mean age = 61.1 years) being investigated for suspected CAD on the basis of symptomatology and positive noninvasive tests, completed 24-hour electrocardiograms. The Beck Depression Inventory (BDI) was administered, and positive and depressed affect was measured over the study period with the Day Reconstruction Method (DRM). A total of 46 (60.5%) patients were later found to have definite CAD. HRV was analyzed, using spectral analysis. Typical diurnal profiles of HRV were observed, with greater normalized high frequency (HF) and lower normalized low frequency (LF) power in the night compared with the day. BDI depression scores were not consistently associated with HRV. But positive affect was associated with greater normalized HF power (p = .039) and reduced normalized LF power (p = .007) independently of age, gender, medication with beta blockers, CAD status, body mass index, smoking, and habitual physical activity level. In patients with definite CAD, depressed affect assessed using the DRM was associated with reduced normalized HF power and heightened normalized LF power (p = .007) independently of covariates. Relationships between depression and HRV in patients with CAD may depend on affective experience over the monitoring period. Enhanced parasympathetic cardiac control may be a process through which positive affect protects against cardiovascular disease.

  13. Use of three-dimensional, CAD/CAM-assisted, virtual surgical simulation and planning in the pediatric craniofacial population.

    Science.gov (United States)

    Gray, Rachel; Gougoutas, Alexander; Nguyen, Vinh; Taylor, Jesse; Bastidas, Nicholas

    2017-06-01

    Virtual Surgical Planning (VSP) and computer-aided design/computer-aided manufacturing (CAD/CAM) have recently helped improve efficiency and accuracy in many different craniofacial surgeries. Research has mainly focused on the use in the adult population with the exception of the use for mandibular distractions and cranial vault remodeling in the pediatric population. This study aims to elucidate the role of VSP and CAD/CAM in complex pediatric craniofacial cases by exploring its use in the correction of midface hypoplasia, orbital dystopia, mandibular reconstruction, and posterior cranial vault expansion. A retrospective analysis of thirteen patients who underwent 3d, CAD/CAM- assisted preoperative surgical planning between 2012 and 2016 was performed. All CAD/CAM assisted surgical planning was done in conjunction with a third party vendor (either 3D Systems or Materialise). Cutting and positioning guides as well as models were produced based on the virtual plan. Surgeries included free fibula mandible reconstruction (n = 4), lefort I osteotomy and distraction (n = 2), lefort II osteotomy with monobloc distraction (n = 1), expansion of the posterior vault for correction of chiari malformation (n = 3), and secondary orbital and midface reconstruction for facial trauma (n = 3). The patient's age, diagnosis, previous surgeries, length of operating time, complications, and post-surgery satisfaction were determined. In all cases we found presurgical planning was helpful to improve accuracy and significantly decrease intra-operative time. In cases where distraction was used, the planned and actual vectors were found to be accurate with excellent clinical outcomes. There were no complications except for one patient who experienced a wound infection post-operatively which did not alter the ultimate reconstruction. All patients experienced high satisfaction with their outcomes and excellent subjective aesthetic results were achieved. Preoperative planning using

  14. The Nucleotide Synthesis Enzyme CAD Inhibits NOD2 Antibacterial Function in Human Intestinal Epithelial Cells

    Science.gov (United States)

    Richmond, Amy L.; Kabi, Amrita; Homer, Craig R.; García, Noemí Marina; Nickerson, Kourtney P.; NesvizhskiI, Alexey I.; Sreekumar, Arun; Chinnaiyan, Arul M.; Nuñez, Gabriel; McDonald, Christine

    2013-01-01

    BACKGROUND & AIMS Polymorphisms that reduce the function of nucleotide-binding oligomerization domain (NOD)2, a bacterial sensor, have been associated with Crohn’s disease (CD). No proteins that regulate NOD2 activity have been identified as selective pharmacologic targets. We sought to discover regulators of NOD2 that might be pharmacologic targets for CD therapies. METHODS Carbamoyl phosphate synthetase/ aspartate transcarbamylase/dihydroorotase (CAD) is an enzyme required for de novo pyrimidine nucleotide synthesis; it was identified as a NOD2-interacting protein by immunoprecipitation-coupled mass spectrometry. CAD expression was assessed in colon tissues from individuals with and without inflammatory bowel disease by immunohistochemistry. The interaction between CAD and NOD2 was assessed in human HCT116 intestinal epithelial cells by immunoprecipitation, immunoblot, reporter gene, and gentamicin protection assays. We also analyzed human cell lines that express variants of NOD2 and the effects of RNA interference, overexpression and CAD inhibitors. RESULTS CAD was identified as a NOD2-interacting protein expressed at increased levels in the intestinal epithelium of patients with CD compared with controls. Overexpression of CAD inhibited NOD2-dependent activation of nuclear factor κB and p38 mitogen-activated protein kinase, as well as intracellular killing of Salmonella. Reduction of CAD expression or administration of CAD inhibitors increased NOD2-dependent signaling and antibacterial functions of NOD2 variants that are and are not associated with CD. CONCLUSIONS The nucleotide synthesis enzyme CAD is a negative regulator of NOD2. The antibacterial function of NOD2 variants that have been associated with CD increased in response to pharmacologic inhibition of CAD. CAD is a potential therapeutic target for CD. PMID:22387394

  15. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  16. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Determinación del centro de esfuerzo en un troquel de corte utilizando un programa CAD

    OpenAIRE

    BALDI DE COSTA, CLARA

    2006-01-01

    Se discute la importancia de la correcta ubicación del centro de esfuerzo en un troquel de corte para minimizar las cargas laterales sobre los , elementos de guía. Se describe el proceso matemático para determinar el centro de esfuerzo a través del cálculo del centroide de una curva, y sucesivamente se proporciona un método de aproximación que utiliza la capacidad de AutoCAD de calcular el centroide de una región plana bidimensional. The importance of a correct positioning of the force cen...

  18. Association of homocysteine and methylene tetrahydrofolate reductase (MTHFR C677T) gene polymorphism with coronary artery disease (CAD) in the population of North India

    Science.gov (United States)

    2010-01-01

    The implications of the methylene tetrahydrofolate reductase (MTHFR) gene and the level of homocysteine in the pathogenesis of coronary artery disease (CAD) have been extensively studied in various ethnic groups. Our aim was to discover the association of MTHFR (C677T) polymorphism and homocysteine level with CAD in north Indian subjects. The study group consisted of 329 angiographically proven CAD patients, and 331 age and sex matched healthy individuals as controls. MTHFR (C677T) gene polymorphism was detected based on the polymerase chain reaction and restriction digestion with HinfI. Total homocysteine plasma concentration was measured using immunoassay. T allele frequency was found to be significantly higher in patients than in the control group. We found significantly elevated levels of mean homocysteine in the patient group when compared to the control group (p = 0.00). Traditional risk factors such as diabetes, hypertension, smoking habits, a positive family history and lipid profiles (triglyceride, total cholesterol, HDL-cholesterol, LDL-cholesterol, VLDL-cholesterol), were found significantly associated through univariate analysis. Furthermore, multivariable logistics regression analysis revealed that CAD is significantly and variably associated with diabetes, hypertension, smoking, triglycerides and HDL-cholesterol. Our findings showed that MTHFR C677T polymorphism and homocysteine levels were associated with coronary artery disease in the selected population. PMID:21637473

  19. Cavernous hemangioma presenting marked hyperostosis

    International Nuclear Information System (INIS)

    Kobata, Hitoshi; Miyake, Hiroji; Kitamura, Junji; Kajikawa, Hiroshi; Ohta, Tomio

    1988-01-01

    The authors report here a case of hemangioma of the left parietal bone which presented headache and papilledema. This patient is a 37-year-old female who had, prior to admission, complained of increasing headache for one year and blurred vision for three months. She had no history of head injury. Local physical examinations revealed a slight bulging in her left parietal region which was insensitive to palpation and not adherent to the overlying scalp. Neurological examinations revealed bilateral papilledema and an incongruous bitemporal upper quadrant defect in the visual field. All the other neurological and laboratory data were normal. A plain skull roentogenogram showed a 9 x 9 cm osteolytic and characteristic honeycomb lesion in the parietal region. Systemic bone survey revealed a similar lesion in the right tibia which was not histologically examined. A marked accumulation of isotopes was detected on the bone scintigrams at both lesions. Selective external carotid angiograms demonstrated a tumor stain fed by the superficial temporal, occipital, and middle meningial arteries. CT scans of the brain and skull clearly showed a local thickening of and structural changes in the skull bone and also a mass effect on the brain and lateral ventricle. The lesioned bone was removed en bloc and replaced by an artificial bone. It was highly vascular, but not adherent to the overlying dura. The post-operative course was uneventful, and the headache and papilledema disappeared. Hemangioma of the skull presenting marked hyperostosis, as reported above, seems to be rare. In addition, in this case, skeletal angioma without any clinical manifestation was detected. Clinical and radiological pictures of the hemangioma of the skull and other bones were briefly discussed. (author)

  20. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  1. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  2. Detection and recognition of road markings in panoramic images

    Science.gov (United States)

    Li, Cheng; Creusen, Ivo; Hazelhoff, Lykele; de With, Peter H. N.

    2015-03-01

    Detection of road lane markings is attractive for practical applications such as advanced driver assistance systems and road maintenance. This paper proposes a system to detect and recognize road lane markings in panoramic images. The system can be divided into four stages. First, an inverse perspective mapping is applied to the original panoramic image to generate a top-view road view, in which the potential road markings are segmented based on their intensity difference compared to the surrounding pixels. Second, a feature vector of each potential road marking segment is extracted by calculating the Euclidean distance between the center and the boundary at regular angular steps. Third, the shape of each segment is classified using a Support Vector Machine (SVM). Finally, by modeling the lane markings, previous falsely detected segments can be rejected based on their orientation and position relative to the lane markings. Our experiments show that the system is promising and is capable of recognizing 93%, 95% and 91% of striped line segments, blocks and arrows respectively, as well as 94% of the lane markings.

  3. Large scale validation of the M5L lung CAD on heterogeneous CT datasets

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Torres, E., E-mail: Ernesto.Lopez.Torres@cern.ch, E-mail: cerello@to.infn.it [CEADEN, Havana 11300, Cuba and INFN, Sezione di Torino, Torino 10125 (Italy); Fiorina, E.; Pennazio, F.; Peroni, C. [Department of Physics, University of Torino, Torino 10125, Italy and INFN, Sezione di Torino, Torino 10125 (Italy); Saletta, M.; Cerello, P., E-mail: Ernesto.Lopez.Torres@cern.ch, E-mail: cerello@to.infn.it [INFN, Sezione di Torino, Torino 10125 (Italy); Camarlinghi, N.; Fantacci, M. E. [Department of Physics, University of Pisa, Pisa 56127, Italy and INFN, Sezione di Pisa, Pisa 56127 (Italy)

    2015-04-15

    Purpose: M5L, a fully automated computer-aided detection (CAD) system for the detection and segmentation of lung nodules in thoracic computed tomography (CT), is presented and validated on several image datasets. Methods: M5L is the combination of two independent subsystems, based on the Channeler Ant Model as a segmentation tool [lung channeler ant model (lungCAM)] and on the voxel-based neural approach. The lungCAM was upgraded with a scan equalization module and a new procedure to recover the nodules connected to other lung structures; its classification module, which makes use of a feed-forward neural network, is based of a small number of features (13), so as to minimize the risk of lacking generalization, which could be possible given the large difference between the size of the training and testing datasets, which contain 94 and 1019 CTs, respectively. The lungCAM (standalone) and M5L (combined) performance was extensively tested on 1043 CT scans from three independent datasets, including a detailed analysis of the full Lung Image Database Consortium/Image Database Resource Initiative database, which is not yet found in literature. Results: The lungCAM and M5L performance is consistent across the databases, with a sensitivity of about 70% and 80%, respectively, at eight false positive findings per scan, despite the variable annotation criteria and acquisition and reconstruction conditions. A reduced sensitivity is found for subtle nodules and ground glass opacities (GGO) structures. A comparison with other CAD systems is also presented. Conclusions: The M5L performance on a large and heterogeneous dataset is stable and satisfactory, although the development of a dedicated module for GGOs detection could further improve it, as well as an iterative optimization of the training procedure. The main aim of the present study was accomplished: M5L results do not deteriorate when increasing the dataset size, making it a candidate for supporting radiologists on large

  4. Accuracy of CAD-CAM-fabricated removable partial dentures.

    Science.gov (United States)

    Arnold, Christin; Hey, Jeremias; Schweyen, Ramona; Setz, Jürgen M

    2018-04-01

    The conventional fabrication of removable partial dentures (RPDs) is a complex, error-prone, time-consuming, and expensive process. The use of computer-aided design and computer-aided manufacturing (CAD-CAM) techniques, especially rapid prototyping, promises a more effective method for fabricating RPD frameworks. The purpose of this in vitro study was to evaluate the fit of RPD clasps fabricated by means of 4 different CAD-CAM-systems and to compare those fittings with that of the conventional lost-wax casting technique (LWT). A master model of a partially edentulous maxilla with the canines and second molars as the remaining teeth was fabricated. After the model was optically scanned, we designed a quadrangularly supported RPD with 4 clasps and a palatal strap major connector. A standard tessellation language data set was used to fabricate 12 identical RPDs by using 4 different CAD-CAM techniques: indirect rapid prototyping (wax inject printing combined with LWT), direct rapid prototyping (selective laser melting), indirect milling (wax milling with LWT), and direct milling (resin milling [polyetheretherketone]). Three conventionally cast RPDs (LWT) served as the control group. The fit accuracy of the clasps (n=12 for each group) was determined in both the horizontal and vertical dimensions by using light microscopy. Indirectly milled RPDs (117 ±34 μm horizontal and 45 ±21 μm vertical) and directly milled RPDs (43 ±23 μm horizontal, and 38 ±21 μm vertical) showed significantly better (P<.05) fit than did conventionally fabricated LWT RPDs (133 ±59 μm horizontal; 73 ±25 μm vertical). The worst fit was found for RPDs fabricated using indirect rapid prototyping (323 ±188 μm horizontal and 112 ±60 μm vertical) or direct rapid prototyping (365 ±205 μm horizontal and 363 ±133 μm vertical), which were unstable on the master model, making them unsuitable for clinical use. Most RPDs exhibited smaller vertical measuring distances. Compared with the LWT

  5. PV-CAD: an integrated tool for designing PV facades; PV-CAD - Ein integriertes Werkzeug zur Auslegung von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Giese, H.; Viotto, M. [Inst. fuer Solare Energieversorgungstechnik (ISET) e.V., Kassel (Germany); Esser, M.; Pukrop, D. [Univ. Oldenburg (Germany). Abt. Energie- und Halbleiterforschung; Stellbogen, D. [Zentrum fuer Sonnenergie- und Wasserstoff-Forschung, Stuttgart (Germany)

    1997-12-31

    PV-CAD provides PV system planners with a practice-oriented tool for an efficient design of PV facades. Being compatible with the standard programmes of the architects` and electrical engineering sectors it can be used on already existing systems and allows the user to draw on previously acquired knowedge. Its open interfaces permit the integration of further design tools. PV CAD works under Microsoft Windows for which it has the necessary graphic user interface. Its compliance to PC standards opens up a wide range of applications and permits its use also on inexpensive computers. Thanks to its promotion by the Federal Ministry for Education, Science, Research, and Technology under the research project ``Computer programmes for the design of photovoltaic facades`` PV-CAD is available at a moderate price. PV-CAD permits an efficient planning of solar facades and therefore has the potential to stimulate the use of PV on buildings. (orig.) [Deutsch] Mit PV-CAD steht dem Anlagenplaner ein anwendungsorientiertes Werkzeug zur Verfuegung, das eine rationelle Auslegung von PV-Fassaden ermoeglicht. Die Kompatibilitaet zu Standardprogrammen aus dem Architektur- und Elektrosektor erlaubt die Nutzung bereits vorhandener Systeme und damit erworbener Kenntnisse. Offene Schnittstellen gestatten die Einbindung weiterer Entwurfswerkzeuge. PV-CAD arbeitet unter Microsoft-Windows und verfuegt ueber die entsprechende grafische Benutzerschnittstelle. Die Kompatibilitaet zum PC-Standard eroeffnet eine sehr breite Anwenderbasis und ermoeglicht den Einsatz des Programms auch auf preiswerten Rechnern. Aufgrund der Foerderung durch das Bundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie im Rahmen des Forschungsprojekts `Rechnerprogramm zur Auslegung von Photovoltaik-Fassaden` steht PV-CAD preiswert zur Verfuegung. PV-CAD ermoeglicht eine effiziente Planung von Solarfassaden und kann daher dem PV-Einsatz in Gebaeuden weitere Impulse geben. (orig.)

  6. Oxygen binding to nitric oxide marked hemoglobin

    International Nuclear Information System (INIS)

    Louro, S.R.W.; Ribeiro, P.C.; Bemski, G.

    1979-04-01

    Electron spin resonance spectra of organic phosphate free human hemoglobin marked with nitric oxide at the sixth coordination position of one of the four hemes allow to observe the transition from the tense (T) to the relaxed (R) conformation, as a function of parcial oxygen pressure. The spectra are composites of contributions from α sub(T), α sub(R) and β chains spectra, showing the presence of only two conformations: T and R. In the absence of organic phosphates NO binds to α and β chains with the same probability, but in the presence of phosphates NO combines preferentially with α chains. The dissociation of NO proceeds at least an order of magnitude faster in T than in R configuration. (author) [pt

  7. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    Science.gov (United States)

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  8. Mobile Technology and CAD Technology Integration in Teaching Architectural Design Process for Producing Creative Product

    Science.gov (United States)

    Bin Hassan, Isham Shah; Ismail, Mohd Arif; Mustafa, Ramlee

    2011-01-01

    The purpose of this research is to examine the effect of integrating the mobile and CAD technology on teaching architectural design process for Malaysian polytechnic architectural students in producing a creative product. The website is set up based on Caroll's minimal theory, while mobile and CAD technology integration is based on Brown and…

  9. Usefulness of the CAD System for Detecting Pulmonary Nodule in Real Clinical Practice

    International Nuclear Information System (INIS)

    Song, Kyoung Doo; Chung, Myung Jin; Kim, Hee Cheol; Lee, Kyung Soo; Jeong, Sun Young

    2011-01-01

    We wanted to evaluate the usefulness of the computer-aided detection (CAD) system for detecting pulmonary nodules in real clinical practice by using the CT images. Our Institutional Review Board approved our retrospective study with a waiver of informed consent. This study included 166 CT examinations that were performed for the evaluation of pulmonary metastasis in 166 patients with colorectal cancer. All the CT examinations were interpreted by radiologists and they were also evaluated by the CAD system. All the nodules detected by the CAD system were evaluated with regard to whether or not they were true nodules, and they were classified into micro nodules (MN, diameter < 4 mm) and significant nodules (SN, 4 ≤ diameter ≤ 10 mm). The radiologic reports and CAD results were compared. The CAD system helped detect 426 nodules: 115 (27%) of the 426 nodules were classified as true nodules and 35 (30%) of the 115 nodules were SNs, and 83 (72%) of the 115 were not mentioned in the radiologists' reports and three (4%) of the 83 nodules were non-calcified SNs. One of three non-calcified SNs was confirmed as a metastatic nodule. According to the radiologists' reports, 60 true nodules were detected, and 28 of the 60 were not detected by the CAD system. Although the CAD system missed many SNs that are detected by radiologists, it helps detect additional nodules that are missed by the radiologists in real clinical practice. Therefore, the CAD system can be useful to support a radiologist's detection performance

  10. 3D-CAD Effects on Creative Design Performance of Different Spatial Abilities Students

    Science.gov (United States)

    Chang, Y.

    2014-01-01

    Students' creativity is an important focus globally and is interrelated with students' spatial abilities. Additionally, three-dimensional computer-assisted drawing (3D-CAD) overcomes barriers to spatial expression during the creative design process. Does 3D-CAD affect students' creative abilities? The purpose of this study was to explore the…

  11. The Use of a Parametric Feature Based CAD System to Teach Introductory Engineering Graphics.

    Science.gov (United States)

    Howell, Steven K.

    1995-01-01

    Describes the use of a parametric-feature-based computer-aided design (CAD) System, AutoCAD Designer, in teaching concepts of three dimensional geometrical modeling and design. Allows engineering graphics to go beyond the role of documentation and communication and allows an engineer to actually build a virtual prototype of a design idea and…

  12. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  13. Integration of computer-aided diagnosis/detection (CAD) results in a PACS environment using CAD-PACS toolkit and DICOM SR

    International Nuclear Information System (INIS)

    Le, Anh H.T.; Liu, Brent; Huang, H.K.

    2009-01-01

    Picture Archiving and Communication System (PACS) is a mature technology in health care delivery for daily clinical imaging service and data management. Computer-aided detection and diagnosis (CAD) utilizes computer methods to obtain quantitative measurements from medical images and clinical information to assist clinicians to assess a patient's clinical state more objectively. CAD needs image input and related information from PACS to improve its accuracy; and PACS benefits from CAD results online and available at the PACS workstation as a second reader to assist physicians in the decision making process. Currently, these two technologies remain as two separate independent systems with only minimal system integration. This paper describes a universal method to integrate CAD results with PACS in its daily clinical environment. The method is based on Health Level 7 (HL7) and Digital imaging and communications in medicine (DICOM) standards, and Integrating the Healthcare Enterprise (IHE) workflow profiles. In addition, the integration method is Health Insurance Portability and Accountability Act (HIPAA) compliant. The paper presents (1) the clinical value and advantages of integrating CAD results in a PACS environment, (2) DICOM Structured Reporting formats and some important IHE workflow profiles utilized in the system integration, (3) the methodology using the CAD-PACS integration toolkit, and (4) clinical examples with step-by-step workflows of this integration. (orig.)

  14. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  15. Design of the new couplers for C-ADS RFQ

    Science.gov (United States)

    Shi, Ai-Min; Sun, Lie-Peng; Zhang, Zhou-Li; Xu, Xian-Bo; Shi, Long-Bo; Li, Chen-Xing; Wang, Wen-Bin

    2015-04-01

    A new special coupler with a kind of bowl-shaped ceramic window for a proton linear accelerator named the Chinese Accelerator Driven System (C-ADS) at the Institute of Modern Physics (IMP) has been simulated and constructed and a continuous wave (CW) beam commissioning through a four-meter long radio frequency quadruple (RFQ) was completed by the end of July 2014. In the experiments of conditioning and beam, some problems were promoted gradually such as sparking and thermal issues. Finally, two new couplers were passed with almost 110 kW CW power and 120 kW pulsed mode, respectively. The 10 mA intensity beam experiments have now been completed, and the couplers during the operation had no thermal or electro-magnetic problems. The detailed design and results are presented in the paper. Supported by Strategic Priority Research Program of Chinese Academy of Sciences (XDA03020500)

  16. Integrated electric circuit CAD system in Minolta Camera Co. Ltd

    Energy Technology Data Exchange (ETDEWEB)

    Nakagami, Tsuyoshi; Hirata, Sumiaki; Matsumura, Fumihiko

    1988-08-26

    Development background, fundamental concept, details and future plan of the integrated electric circuit CAD system for OA equipment are presented. The central integrated database is basically intended to store experiences or know-hows, to cover the wide range of data required for designs, and to provide a friendly interface. This easy-to-use integrated database covers the drawing data, parts information, design standards, know-hows and system data. The system contains the circuit design function to support drawing circuit diagrams, the wiring design function to support the wiring and arrangement of printed circuit boards and various parts integratedly, and the function to verify designs, to make full use of parts or technical information, to maintain the system security. In the future, as the system will be wholly in operation, the design period reduction, quality improvement and cost saving will be attained by this integrated design system. (19 figs, 2 tabs)

  17. VLSI Design with Alliance Free CAD Tools: an Implementation Example

    Directory of Open Access Journals (Sweden)

    Chávez-Bracamontes Ramón

    2015-07-01

    Full Text Available This paper presents the methodology used for a digital integrated circuit design that implements the communication protocol known as Serial Peripheral Interface, using the Alliance CAD System. The aim of this paper is to show how the work of VLSI design can be done by graduate and undergraduate students with minimal resources and experience. The physical design was sent to be fabricated using the CMOS AMI C5 process that features 0.5 micrometer in transistor size, sponsored by the MOSIS Educational Program. Tests were made on a platform that transfers data from inertial sensor measurements to the designed SPI chip, which in turn sends the data back on a parallel bus to a common microcontroller. The results show the efficiency of the employed methodology in VLSI design, as well as the feasibility of ICs manufacturing from school projects that have insufficient or no source of funding

  18. Paper-Less CAD/CAM For Accelerator Components

    International Nuclear Information System (INIS)

    Franks, R M; Alford, O; Bertolini, L R

    2001-01-01

    Computer-aided design and manufacture (CAD/CAM) have enabled advances in the design and manufacture of many accelerator components, though government procurement rules tend to inhibit its use. We developed and executed a method that provides adequate documentation for the procurement process, industrial vendor manufacturing processes, and laboratory installation activities. We detail our experiences in the design and manufacture of 60 separate and unique PEP-II Low Energy Ring Interaction Region vacuum chambers totaling ∼ 140m in length as an example of how we used this technique, reducing design effort and manufacturing risk while streamlining the production process. We provide ''lessons learned'' to better implement and execute the process in subsequent iterations. We present our study to determine the estimated savings in the design and production of the Spallation Neutron Source room temperature linac if this process were utilized

  19. Characteristics study of the gears by the CAD/CAE

    Science.gov (United States)

    Wang, P. Y.; Chang, S. L.; Lee, B. Y.; Nguyen, D. H.; Cao, C. W.

    2017-09-01

    Gears are the most important transmission component in machines. The rapid development of the machines in industry requires a shorter time of the analysis process. In traditional, the gears are analyzed by setting up the complete mathematical model firstly, considering the profile of cutter and coordinate systems relationship between the machine and the cutter. It is a really complex and time-consuming process. Recently, the CAD/CAE software is well developed and useful in the mechanical design. In this paper, the Autodesk Inventor® software is introduced to model the spherical gears firstly, and then the models can also be transferred into ANSYS Workbench for the finite element analysis. The proposed process in this paper is helpful to the engineers to speed up the analyzing process of gears in the design stage.

  20. Numerical Analysis of Turbulent Flow around Tube Bundle by Applying CAD Best Practice Guideline

    International Nuclear Information System (INIS)

    Lee, Gong Hee; Bang, Young Seok; Woo, Sweng Woong; Cheng, Ae Ju

    2013-01-01

    In this study, the numerical analysis of a turbulent flow around both a staggered and an incline tube bundle was conducted using Annoys Cfx V. 13, a commercial CAD software. The flow was assumed to be steady, incompressible, and isothermal. According to the CAD Best Practice Guideline, the sensitivity study for grid size, accuracy of the discretization scheme for convection term, and turbulence model was conducted, and its result was compared with the experimental data to estimate the applicability of the CAD Best Practice Guideline. It was concluded that the CAD Best Practice Guideline did not always guarantee an improvement in the prediction performance of the commercial CAD software in the field of tube bundle flow

  1. User productivity as a function of AutoCAD interface design.

    Science.gov (United States)

    Mitta, D A; Flores, P L

    1995-12-01

    Increased operator productivity is a desired outcome of user-CAD interaction scenarios. Two objectives of this research were to (1) define a measure of operator productivity and (2) empirically investigate the potential effects of CAD interface design on operator productivity, where productivity is defined as the percentage of a drawing session correctly completed per unit time. Here, AutoCAD provides the CAD environment of interest. Productivity with respect to two AutoCAD interface designs (menu, template) and three task types (draw, dimension, display) was investigated. Analysis of user productivity data revealed significantly higher productivity under the menu interface condition than under the template interface condition. A significant effect of task type was also discovered, where user productivity under display tasks was higher than productivity under the draw and dimension tasks. Implications of these results are presented.

  2. The efficacy of using CAD for detection of breast cancer in mammography screening A systematic review

    DEFF Research Database (Denmark)

    Henriksen, Emilie; Lauridsen, Carsten Ammitzbøl

    Abstract Purpose: The aim of this systematic review is to present an overview of the available studies concerning the use of computer-aided detection (CAD) systems in screening mammography for early detection of breast cancer and compare the diagnostic accuracy and recall rates of single reading....... The literature search resulted in 1522 records after duplicates were removed. 1491 records were excluded by abstract and 18 were excluded after assessing the eligibility by full text reading. A total of 13 articles were included in this study. Results: The results for the single reading vs. single reading...... with CAD group indicate that the addition of CAD increases sensitivity and cancer detection rate (CDR). For the double reading vs. single reading with CAD group none of the studies reported significant differences in sensitivity and CDR. Adding CAD to single reading increased the recall rates and decreased...

  3. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    Science.gov (United States)

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Geographical variations in the prevalence and management of cardiovascular risk factors in outpatients with CAD: Data from the contemporary CLARIFY registry.

    Science.gov (United States)

    Ferrari, Roberto; Ford, Ian; Greenlaw, Nicola; Tardif, Jean-Claude; Tendera, Michal; Abergel, Hélène; Fox, Kim; Hu, Dayi; Shalnova, Svetlana; Steg, Ph Gabriel

    2015-08-01

    To determine the current prevalence and control of major cardiovascular risk factors in stable CAD outpatients worldwide. We analysed variations in cardiovascular risk factors in stable CAD outpatients from CLARIFY, a 5-year observational longitudinal cohort study, in seven geographical zones (Western/Central Europe; Canada/South Africa/Australia/UK; Eastern Europe; Central/South America; Middle East; East Asia; and India). Patient presentation (N=32,954, mean age 64.2 years, 78% male) varied between zones, as did prevalence of risk factors (all p Asia) to 42% (Middle East), raised blood pressure from 28% (Central/South America and East Asia) to 48% (Eastern Europe), raised LDL cholesterol from 24% (Canada/South Africa/Australia/UK) to 65% (Eastern Europe), elevated heart rate (≥70 bpm) from 38% (Western/Central Europe) to 78% (India), diabetes from 17% (Eastern Europe) to 60% (Middle East), and smoking from 6% (Central/South America) to 19% (Eastern Europe). Aspirin and lipid-lowering drugs were widely used everywhere (≥84% and ≥88%, respectively). Rates of risk factor control varied geographically (all p Asia), controlled LDL cholesterol and dyslipidaemia from 32% (Eastern Europe) to 75% (Canada/South Africa/Australia/UK), heart rate <70 bpm from 22% (India) to 62% (Western/Central Europe), and heart rate ≤60 bpm in angina patients from 2% (India) to 29% (Canada/South Africa/Australia/UK and Central/South America). Prevalence and control of major cardiovascular risk factors in stable CAD vary markedly worldwide. Many stable CAD outpatients are being treated suboptimally. © The European Society of Cardiology 2014.

  5. Cooperative Shark Mark Recapture Database (MRDBS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Shark Mark Recapture Database is a Cooperative Research Program database system used to keep multispecies mark-recapture information in a common format for...

  6. On-road Bicycle Pavement Markings

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — A mile by mile breakdown of the on-street bicycle pavement markings installed within the City of Pittsburgh. These include bike lanes, shared lane markings...

  7. Serviceable pavement marking retroreflectivity levels : technical report.

    Science.gov (United States)

    2009-03-01

    This research addressed an array of issues related to measuring pavement markings retroreflectivity, factors : related to pavement marking performance, subjective evaluation process, best practices for using mobile : retroreflectometers, sampling pav...

  8. CAD Design of Human Male Body for Mass–Inertial Characteristics Studies

    Directory of Open Access Journals (Sweden)

    Nikolova Gergana

    2018-01-01

    Full Text Available The aim of the present research is to present a 16-segmental biomechanical model of the Bulgarian male to determine the mass-inertial characteristics of the body of the Bulgarian male based on parameters available in the literature and its 3D generation within SolidWorks software. The motivation of the research is to support mainly sport, rehabilitation, wearable robots and furniture design users. The proposed CAD model of the human body of men is verified against the analytical results from our previous investigation, as well as through comparison with data available in the provided references. In this paper we model two basic human body positions: standing position and sitting with thighs elevated. The comparison performed between our model results and data reported in literature gives us confidence that this model can be reliably used to calculate the mass-inertial characteristics of male body at any postures of the body that is of interest. Therefore, our model can be used to obtain data for positions which the human body has to take in everyday live, in sport, leisure, including space exploration, for investigating criminology cases – body fall, car crash, etc. The model is suitable for performing computer simulation in robotics, medicine, sport and other areas.

  9. [Marked hemosiderosis in myelodysplastic syndrome].

    Science.gov (United States)

    Klinz, C

    1999-01-29

    A 68-year-old man was admitted because of symptoms of lumbar pain. He was known to have chronic anemia with ring sideroblasts and diabetes melitus and to be in heart failure. Three months before he had been given 7 units of red cell concentrate. On admission the outstanding features were brown discoloration of the skin, absent body hair, tachycardia, hepatomegaly and small testicles. He had a normocytic anemia, hyperglycemia and raised transaminases, hypogonadism and vitamin D3 deficiency. The serum levels of iron, transferrin saturation and feritin were markedly elevated. Liver iron content/g dried liver was 4.2 g (by biomagnetometer). Radiology of the lumbar vertebrae showed osteoporosis and sonography confirmed hepatomegaly. The known myelodysplastic syndrome (MDS) had fed to secondary hemosiderosis with heart failure, liver involvement, diabetes mellitus, hypogonadism and osteoporosis. Symptomatic treatment was unsuccessfully complemented by desferoxamine (up to 4 g/12 h) to release iron. But very good iron excretion was then achieved with deferiprone (3 x 1 g/d). The patient later died of the sequelae of hemosiderosis. Even when they have not required transfusions, patients with long-standing MDS should be examined regularly for the possible development of secondary hemosiderosis so that iron-chelating agents can be administered as needed.

  10. EDMS - Reaching the Million Mark

    CERN Multimedia

    2009-01-01

    When Christophe Seith from the company Cegelec sat down to work on 14 May 2009 at 10:09 a.m. to create the EDMS document entitled "Rapport tournée PH semaine 20", little did he know that he would be the proud creator of the millionth EDMS document and the happy prize winner of a celebratory bottle of champagne to mark the occasion. In the run up to the creation of the millionth EDMS document the EDMS team had been closely monitoring the steady rise in the EDMS number generator, so as to ensure the switch from the six figured i.d. to seven figures would run smoothly and of course, to be able to congratulate the creator of the millionth EDMS document. From left to right: Stephan Petit (GS-ASE- EDS Section Leader), Christophe Delamare (GS- ASE Group Leader), Christophe Seith, creator of the millionth EDMS document, David Widegren, (GS-ASE- EPS Section Leader). The millionth EDMS document. For t...

  11. GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries

    Science.gov (United States)

    Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh

    2018-04-01

    Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.

  12. Predicting Long-term Ischemic Events Using Routine Clinical Parameters in Patients with Coronary Artery Disease: The OPT-CAD Risk Score.

    Science.gov (United States)

    Han, Yaling; Chen, Jiyan; Qiu, Miaohan; Li, Yi; Li, Jing; Feng, Yingqing; Qiu, Jian; Meng, Liang; Sun, Yihong; Tao, Guizhou; Wu, Zhaohui; Yang, Chunyu; Guo, Jincheng; Pu, Kui; Chen, Shaoliang; Wang, Xiaozeng

    2018-06-05

    The prognosis of patients with coronary artery disease (CAD) at hospital discharge was constantly varying, and post-discharge risk of ischemic events remain a concern. However, risk prediction tools to identify risk of ischemia for these patients has not yet been reported. We sought to develop a scoring system for predicting long-term ischemic events in CAD patients receiving antiplatelet therapy that would be beneficial in appropriate personalized decision-making for these patients. In this prospective Optimal antiPlatelet Therapy for Chinese patients with Coronary Artery Disease (OPT-CAD, NCT01735305) registry, a total of 14,032 patients with CAD receiving at least one kind of antiplatelet agent were enrolled from 107 centers across China, from January 2012 to March 2014. The risk scoring system was developed in a derivation cohort (enrolled initially 10,000 patients in the database) using a logistic regression model and was subsequently tested in a validation cohort (the last 4,032 patients). Points in risk score was assigned based on the multivariable odds ratio of each factor. Ischemic events were defined as the composite of cardiac death, myocardial infarction or stroke. Ischemic events occurred in 342 (3.4%) patients in the derivation cohort and 160 (4.0%) patients in the validation cohort during 1-year follow-up. The OPT-CAD score, ranging from 0-257 points, consist of 10 independent risk factors, including age (0-71 points), heart rates (0-36 points), hypertension (0-20 points), prior myocardial infarction (16 points), prior stroke (16 points), renal insufficient (21 points), anemia (19 points), low ejection fraction (22 points), positive cardiac troponin (23 points) and ST-segment deviation (13 points). In predicting 1-year ischemic events, the area under receiver operating characteristics curve were 0.73 and 0.72 in derivation and validation cohort, respectively. The incidences of ischemic events in low- (0-90 points), medium- (91-150 points) and

  13. 46 CFR 122.602 - Hull markings.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hull markings. 122.602 Section 122.602 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150....602 Hull markings. (a) Each vessel must be marked as required by part 67, subpart I, of this chapter...

  14. 7 CFR 160.32 - Marking containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Marking containers. 160.32 Section 160.32 Agriculture... STANDARDS FOR NAVAL STORES Analysis, Inspection, and Grading on Request § 160.32 Marking containers. The interested person shall provide any labor necessary for marking the containers, after the contents have been...

  15. 46 CFR 160.176-23 - Marking.

    Science.gov (United States)

    2010-10-01

    ... of the vessel. (2) The type of vessel. (3) Specific purpose or limitation approved by the Coast Guard...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-23 Marking. (a) General. Each inflatable lifejacket must be marked with the information required by this section. Each marking must be...

  16. 27 CFR 28.123 - Export marks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Export marks. 28.123..., or Transportation to a Manufacturing Bonded Warehouse § 28.123 Export marks. (a) General. In addition... filled under the provisions of part 24 of this chapter, the proprietor shall mark the word “Export” on...

  17. 27 CFR 28.223 - Export marks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Export marks. 28.223... Export marks. In addition to the marks and brands required to be placed on kegs, barrels, cases, crates... “Export” on each container or case before removal for export, for use on vessels or aircraft, or for...

  18. TU-G-204-09: The Effects of Reduced- Dose Lung Cancer Screening CT On Lung Nodule Detection Using a CAD Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Kim, G; Hsu, W; Hoffman, J; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2015-06-15

    Purpose: While Lung Cancer Screening CT is being performed at low doses, the purpose of this study was to investigate the effects of further reducing dose on the performance of a CAD nodule-detection algorithm. Methods: We selected 50 cases from our local database of National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data from the original scans. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. 10 of the cases had at least one nodule reported on the NLST reader forms. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, the CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST reports. Subject-level mean sensitivities and false-positive rates were calculated for each dose level. Results: The mean sensitivities of the CAD algorithm were 35% at the original dose, 20% at 50% dose, and 42.5% at 25% dose. The false-positive rates, in decreasing-dose order, were 3.7, 2.9, and 10 per case. In certain cases, particularly in larger patients, there were severe photon-starvation artifacts, especially in the apical region due to the high-attenuating shoulders. Conclusion: The detection task was challenging for the CAD algorithm at all dose levels, including the original NLST dose. However, the false-positive rate at 25% dose approximately tripled, suggesting a loss of CAD robustness somewhere between 0.5 and 1.0 mGy. NCI grant U01 CA181156 (Quantitative Imaging Network); Tobacco Related Disease Research Project grant 22RT-0131.

  19. TU-G-204-09: The Effects of Reduced- Dose Lung Cancer Screening CT On Lung Nodule Detection Using a CAD Algorithm

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Kim, G; Hsu, W; Hoffman, J; Brown, M; McNitt-Gray, M

    2015-01-01

    Purpose: While Lung Cancer Screening CT is being performed at low doses, the purpose of this study was to investigate the effects of further reducing dose on the performance of a CAD nodule-detection algorithm. Methods: We selected 50 cases from our local database of National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data from the original scans. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. 10 of the cases had at least one nodule reported on the NLST reader forms. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, the CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST reports. Subject-level mean sensitivities and false-positive rates were calculated for each dose level. Results: The mean sensitivities of the CAD algorithm were 35% at the original dose, 20% at 50% dose, and 42.5% at 25% dose. The false-positive rates, in decreasing-dose order, were 3.7, 2.9, and 10 per case. In certain cases, particularly in larger patients, there were severe photon-starvation artifacts, especially in the apical region due to the high-attenuating shoulders. Conclusion: The detection task was challenging for the CAD algorithm at all dose levels, including the original NLST dose. However, the false-positive rate at 25% dose approximately tripled, suggesting a loss of CAD robustness somewhere between 0.5 and 1.0 mGy. NCI grant U01 CA181156 (Quantitative Imaging Network); Tobacco Related Disease Research Project grant 22RT-0131

  20. Transition-Marking Behaviors of Adolescent Males at First Intercourse.

    Science.gov (United States)

    McLean, Ann L.; Flanigan, Beverly J.

    1993-01-01

    Examined male transition-marking behaviors from adolescence into adulthood at first intercourse. Findings from 80 adolescent males revealed that alcohol use at first intercourse was unrelated to use of contraceptives at that time but was inversely related to whether first intercourse was planned. Planning was positively related to contraceptive…

  1. The Mark III vertex chamber and prototype test results

    International Nuclear Information System (INIS)

    Grab, C.

    1987-07-01

    A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype

  2. Digital Sketch Modelling: Integrating Digital Sketching as a Transition between Sketching and CAD in Industrial Design Education

    Science.gov (United States)

    Ranscombe, Charlie; Bissett-Johnson, Katherine

    2017-01-01

    Literature on the use of design tools in educational settings notes an uneasy relationship between student use of traditional hand sketching and digital modelling tools (CAD) during the industrial design process. This is often manifested in the transition from sketching to CAD and exacerbated by a preference of current students to use CAD. In this…

  3. Computer Aided Design in FE. Some Suggestions on the Inclusion of CAD Topics in Mechanical Engineering Courses. An Occasional Paper.

    Science.gov (United States)

    Ingham, P. C.

    This report investigates the feasibility of including computer aided design (CAD) materials in engineering courses. Section 1 briefly discusses the inevitability of CAD being adopted widely by British industry and the consequent need for its inclusion in engineering syllabi at all levels. A short description of what is meant by CAD follows in…

  4. The mismatch repair protein MLH1 marks a subset of strongly interfering crossovers in tomato

    NARCIS (Netherlands)

    Lhuissier, F.G.P.; Offenberg, H.H.; Wittich, P.E.; Vischer, N.O.E.; Heyting, C.

    2007-01-01

    In most eukaryotes, the prospective chromosomal positions of meiotic crossovers are marked during meiotic prophase by protein complexes called late recombination nodules (LNs). In tomato (Solanum lycopersicum), a cytological recombination map has been constructed based on LN positions. We

  5. The Association between Androgenic Hormone Levels and the Risk of Developing Coronary Artery Disease (CAD).

    Science.gov (United States)

    Allameh, Farzad; Pourmand, Gholamreza; Bozorgi, Ali; Nekuie, Sepideh; Namdari, Farshad

    2016-01-01

    The aim of the study was to evaluate the relationship between the serum levels of androgens and Coronary Artery Disease (CAD) in an Iranian population. Male individuals admitted to Tehran Heart Center and Sina Hospital, Tehran, Iran from 2011-2012 were categorized into CAD and control groups based on selective coronary angiography. Baseline demographic data, including age, BMI, diabetes, and a history of hypertension were recorded. Patients were also assessed for their serum levels of total testosterone, free testosterone, estradiol, dehydroepi and rosterone sulfate (DHEA-S), and Sex Hormone Binding Globulin (SHBG). Data analysis was carried out chi-square and ANOVA tests as well as logistic regression analysis. Two hundred patients were in the CAD group and 135 individuals in control group. In the CAD group, 69 had single-vessel disease, 49 had two-vessel diseases, and 82 had three-vessel diseases. Statistically significant differences were observed between the individuals in the two groups with respect to age (PCAD group; however, the serum level of SHBG was higher in the CAD group than in the control group (P=0.007). Results of the logistic regression analysis indicated that only age (P=0.042) and diabetes (P=0.003) had significant relationships with CAD. Although the serum levels of some of the androgens were significantly different between the two groups, no association was found between androgenic hormone levels and the risk of CAD, due mainly to the effect of age and diabetes.

  6. A multi-user selective undo/redo approach for collaborative CAD systems

    Directory of Open Access Journals (Sweden)

    Yuan Cheng

    2014-04-01

    Full Text Available The engineering design process is a creative process, and the designers must repeatedly apply Undo/Redo operations to modify CAD models to explore new solutions. Undo/Redo has become one of most important functions in interactive graphics and CAD systems. Undo/Redo in a collaborative CAD system is also very helpful for collaborative awareness among a group of cooperative designers to eliminate misunderstanding and to recover from design error. However, Undo/Redo in a collaborative CAD system is much more complicated. This is because a single erroneous operation is propagated to other remote sites, and operations are interleaved at different sites. This paper presents a multi-user selective Undo/Redo approach in full distributed collaborative CAD systems. We use site ID and State Vectors to locate the Undo/Redo target at each site. By analyzing the composition of the complex CAD model, a tree-like structure called Feature Combination Hierarchy is presented to describe the decomposition of a CAD model. Based on this structure, the dependency relationship among features is clarified. B-Rep re-evaluation is simplified with the assistance of the Feature Combination Hierarchy. It can be proven that the proposed Undo/Redo approach satisfies the intention preservation and consistency maintenance correctness criteria for collaborative systems.

  7. CAD-centric Computation Management System for a Virtual TBM. Final Report

    International Nuclear Information System (INIS)

    Munipalli, Ramakanth; Szema, K.Y.; Huang, P.Y.; Rowell, C.M.; Ying, A.; Abdou, M.

    2011-01-01

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  8. Model-Based Engineering and Manufacturing CAD/CAM Benchmark

    International Nuclear Information System (INIS)

    Domm, T.D.; Underwood, R.S.

    1999-01-01

    The Benehmark Project was created from a desire to identify best practices and improve the overall efficiency and performance of the Y-12 Plant's systems and personnel supporting the manufacturing mission. The mission of the benchmark team was to search out industry leaders in manufacturing and evaluate their engineering practices and processes to determine direction and focus fm Y-12 modmizadon efforts. The companies visited included several large established companies and anew, small, high-tech machining firm. As a result of this effort changes are recommended that will enable Y-12 to become a more responsive cost-effective manufacturing facility capable of suppording the needs of the Nuclear Weapons Complex (NW at sign) and Work Fw Others into the 21' century. The benchmark team identified key areas of interest, both focused and gencml. The focus arm included Human Resources, Information Management, Manufacturing Software Tools, and Standarda/ Policies and Practices. Areas of general interest included Inhstructure, Computer Platforms and Networking, and Organizational Structure. The method for obtaining the desired information in these areas centered on the creation of a benchmark questionnaire. The questionnaire was used throughout each of the visits as the basis for information gathering. The results of this benchmark showed that all companies are moving in the direction of model-based engineering and manufacturing. There was evidence that many companies are trying to grasp how to manage current and legacy data. In terms of engineering design software tools, the companies contacted were using both 3-D solid modeling and surfaced Wire-frame models. The manufacturing computer tools were varie4 with most companies using more than one software product to generate machining data and none currently performing model-based manufacturing (MBM) ftom a common medel. The majority of companies were closer to identifying or using a single computer-aided design (CAD) system

  9. High contrast laser marking of alumina

    International Nuclear Information System (INIS)

    Penide, J.; Quintero, F.; Riveiro, A.; Fernández, A.; Val, J. del; Comesaña, R.; Lusquiños, F.; Pou, J.

    2015-01-01

    Highlights: • Laser marking of alumina using near infrared (NIR) lasers was experimentally analyzed. • Color change produced by NIR lasers is due to thermally induced oxygen vacancies. • Laser marking results obtained using NIR lasers and green laser are compared. • High contrast marks on alumina were achieved. - Abstract: Alumina serves as raw material for a broad range of advanced ceramic products. These elements should usually be identified by some characters or symbols printed directly on them. In this sense, laser marking is an efficient, reliable and widely implemented process in industry. However, laser marking of alumina still leads to poor results since the process is not able to produce a dark mark, yielding bad contrast. In this paper, we present an experimental study on the process of marking alumina by three different lasers working in two wavelengths: 1064 nm (Near-infrared) and 532 nm (visible, green radiation). A colorimetric analysis has been carried out in order to compare the resulting marks and its contrast. The most suitable laser operating conditions were also defined and are reported here. Moreover, the physical process of marking by NIR lasers is discussed in detail. Field Emission Scanning Electron Microscopy, High Resolution Transmission Electron Microscopy and X-ray Photoelectron Spectroscopy were also employed to analyze the results. Finally, we propose an explanation for the differences of the coloration induced under different atmospheres and laser parameters. We concluded that the atmosphere is the key parameter, being the inert one the best choice to produce the darkest marks

  10. METABOLIC AND AUTOIMMUNE RISK FACTORS FOR CORONARY ARTERY DISEASE (CAD IN HEART TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    T. A. Khalilulin

    2010-01-01

    Full Text Available One of the most essential autoimmunity risk factors for development of CAD are increasing level of anticardiolipin antibodies and homocystein. This report presents retrospective analyses of 39 heart transplant recipients with maximal follow up over 16 years. Our results showed that hyperhomocystenemia and high levels of anticardiolipin antibodies play great value in development of CAD. Thus relative risks for development of CAD in presence both high levels of anticardiolipin antibodies and homocysteine are higher, than in traditional nonimmune risk factors. 

  11. A Step-by-Step Conservative Approach for CAD-CAM Laminate Veneers

    Directory of Open Access Journals (Sweden)

    Gerardo Durán Ojeda

    2017-01-01

    Full Text Available The use of CAD/CAM technology has allowed the fabrication of ceramic restorations efficiently and with predictable results. Lithium disilicate is a type of glass ceramic material that can be used for the elaboration of laminate veneers, being monolithic restorations which require characterization through a covering ceramic in order to achieve acceptable esthetic results. The next case report shows a predictable clinical protocol for the rehabilitation of the anterior teeth through the preparation of CAD/CAM veneers (e.max CAD, Ivoclar Vivadent, Liechtenstein which have been characterized by a nanofluorapatite ceramic (e.max Ceram, Ivoclar Vivadent, Liechtenstein through the layering technique.

  12. Integrating 3D CAD data for manufacturing and fabrication the core model of reactor TRIGA PUSPATI

    International Nuclear Information System (INIS)

    Abu Bakar Harun

    2005-01-01

    This paper describe the intrigue integration of digital 3 Dimensional Computer Aided Design (3D CAD) data manipulation for the Core Model fabrication of REAKTOR TRIGA PUSPATI and ready for mass manufacturing. 3 Dimensional CAD data from Computer Aided Design program will be used as an interpreter in the fabrication of this project. The Core Model of REAKTOR TRIGA PUSPATI will be fabricated with the aid of 3D CAD drawings and digital files. The components will be segregated and divided into 2 categories namely Conventional d Rapid Fabrication. (Author)

  13. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  14. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    International Nuclear Information System (INIS)

    MORRIS, J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-01-01

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods

  15. CT Colonography: Role of a second reader CAD paradigm in the initial training of radiologists

    International Nuclear Information System (INIS)

    Neri, Emanuele; Faggioni, Lorenzo; Regge, Daniele; Vagli, Paola; Turini, Francesca; Cerri, Francesca; Picano, Eugenia; Giusti, Sabina; Bartolozzi, Carlo

    2011-01-01

    Purpose: To evaluate the influence of CAD for the evaluation of CT colonography (CTC) datasets by inexperienced readers during the attendance of a dedicated hands-on training course. Method and materials: Twenty-seven radiologists inexperienced in CTC (11 with no CTC training at all, 16 having previously reviewed no more than 10 CTC cases overall) attended a hands-on training course based on direct teaching on fifteen workstations (four Advantage Windows 4.4 with Colon VCAR software, GE; six CADCOLON, Im3D; five ColonScreen (Toshiba/Voxar) with ColonCAD TM API, Medicsight). During the course, readers were instructed to analyze 26 CTC cases including 38 colonic lesions obtained through low-dose MDCT acquisitions, consisting of 12 polyps sized less than 6 mm, 9 polyps sized between 6 and 10 mm, 12 polyps sized between 11 mm and 30 mm, and 5 colonic masses sized >3 cm. CTC images were reviewed by each reader both in 2D and 3D mode, respectively by direct evaluation of native axial images and MPR reconstructions, and virtual endoscopy or dissected views. Each reader had 15 min time for assessing each dataset without CAD, after which results were compared with those provided by CAD software. Global rater sensitivity for each lesion size before and after CAD usage was compared by means of two-tailed Student's t test, while sensitivity of each single reader before and after CAD usage was assessed with the McNemar test. Results: For lesions sized 30 mm, sensitivity before CAD-assisted reading was 0.3556 ± 0.3105 and did not change after CAD usage (p = 1). Sensitivity of each single rater did not significantly differ before and after CAD for any lesion size category (McNemar test, p > 0.05). Specificity was not significantly different before and after CAD for any lesion size (>96% for all size categories). Conclusion: CAD usage led to increased overall sensitivity of inexperienced readers for all polyps sizes, except for lesions >30 mm, but sensitivity of individual raters

  16. Introduction to AutoCAD 2013 2D and 3D design

    CERN Document Server

    Yarwood, Alf

    2013-01-01

    Master the complexities of the world's bestselling 2D and 3D software with Alf Yarwood's Introduction to AutoCAD 2013. Ideally suited to new users of AutoCAD, this book will be a useful resource for drawing modules in both vocational and introductory undergraduate courses in engineering and construction.Alf Yarwood has once again produced a comprehensive, step-by-step introduction to the latest release of AutoCAD. Covering all the basic principles and acting as an introduction to 2D drawing, it also contains extensive coverage of all 3D topics, including 3D solid modelling a

  17. Building of a CAD system for I and C system of nuclear power plant

    International Nuclear Information System (INIS)

    Ma Zhicai; Zhang Dongsheng

    2013-01-01

    An I and C database was developed based on the design objects and properties presented in I and C design documents of nuclear power plant. With the database, a rapid-implemented CAD system for I and C engineering was designed and implemented with popular CAD software, AutoCAD and Visio, and desktop database management system, Access, to manage the design data and to automate the composing task for listings, forms and drawings. This system was applied in an engineering project for data management, document generation and drawing aid, and demonstrated its usability and efficiency. (authors)

  18. Complete PCB design using OrCAD capture and PCB editor

    CERN Document Server

    Mitzner, Kraig

    2009-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Editor. Capture is used to build the schematic diagram of the circuit, and Editor is used to design the circuit board so that it can be manufactured. The book is written for both students and practicing engineers who need in-depth instruction on how to use the software, and who need background knowledge of the PCB design process. KEY FEATURES:* Beginning to end cove

  19. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    MORRIS,J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-10-15

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods.

  20. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns.

    Science.gov (United States)

    Kassem, Amr S; Atta, Osama; El-Mowafy, Omar

    2012-01-01

    The aim of this study was to determine effect of compressive cyclic loading on fatigue resistance and microleakage of monolithic CAD/CAM molar ceramic and composite crowns. Thirty-two extracted molars were prepared to receive CEREC crowns according to manufacturer's guidelines using a special paralleling device (Parallel-A-Prep). Sixteen feldspathic ceramic crowns (VITABLOCS Mark II) (VMII) and 16 resin-composite crowns (Paradigm-MZ100 blocks) (PMZ) were milled using a CEREC-3D machine. Eight crowns of each group were cemented to their respective teeth using self-etching resin cement (Panavia-F-2.0) (PAN), and eight were cemented using self-adhesive resin cement (RelyX-Unicem-Clicker) (RXU). Following storage for 1 week in water, specimens were subjected to uniaxial compressive cyclic loading in an Instron testing machine at 12 Hz for 1,000,000 cycles. Load was applied at the central fossa, and the cycle range was 60-600 N. Specimens were then subjected to microleakage testing. Data were statistically analyzed using factorial ANOVA and Post Hoc (Tukey HSD) tests. All composite crowns survived compressive cyclic loading without fracture, while three ceramic crowns from the subgroup cemented with RXU developed surface cracks at the center of occlusal surfaces, extending laterally. Microleakage scores of ceramic crowns cemented with PAN were significantly lower than those of the other three subgroups (p < 0.05). After 1,000,000 cycles of compressive cyclic loading, PMZ composite molar crowns were more fatigue-resistant than VMII ceramic crowns. Cement type had a significant effect on fatigue resistance of the ceramic crowns but not the composite ones. Microleakage scores of ceramic crowns cemented with PAN were significantly lower than those of the other subgroups (p < 0.05). © 2011 by The American College of Prosthodontists.

  1. Contribution of genetic background, traditional risk factors, and HIV-related factors to coronary artery disease events in HIV-positive persons

    DEFF Research Database (Denmark)

    Rotger, Margalida; Glass, Tracy R; Junier, Thomas

    2013-01-01

    in the setting of HIV infection. METHODS: In the general population, 23 common single-nucleotide polymorphisms (SNPs) were shown to be associated with CAD through genome-wide association analysis. Using the Metabochip, we genotyped 1875 HIV-positive, white individuals enrolled in 24 HIV observational studies......, including 571 participants with a first CAD event during the 9-year study period and 1304 controls matched on sex and cohort. RESULTS: A genetic risk score built from 23 CAD-associated SNPs contributed significantly to CAD (P = 2.9 × 10(-4)). In the final multivariable model, participants...

  2. The value of radionuclide phase analysis and parameters of cardial function for diagnosis CAD at rest and during exercise

    International Nuclear Information System (INIS)

    Huang Gang

    1990-01-01

    27 patients and 5 normal were studied with ECG-gated cardial blood pool images and radionuclide phase analysis at rest and during exercise. The results showed that the sensitivity of LVEF in CAD at rest and during exercise were 57% and 71% respectively, and the sensitivity of the ventricular phase in CAD were 79% at rest and 90% during exercise, and the sensitivity of phase angle in CAD were higher than of LVEF. This suggested that the ventricular phase angle was important for diagnosing early CAD. In addition, regional EF, phase image and ventricular wall motion were useful to detect the lesion of ischemia in CAD

  3. The prediction of breast cancer biopsy outcomes using two CAD approaches that both emphasize an intelligible decision process

    International Nuclear Information System (INIS)

    Elter, M.; Schulz-Wendtland, R.; Wittenberg, T.

    2007-01-01

    Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, several computer-aided diagnosis (CAD) systems have been proposed in the last several years. These systems help physicians in their decision to perform a breast biopsy on a suspicious lesion seen in a mammogram or to perform a short term follow-up examination instead. We present two novel CAD approaches that both emphasize an intelligible decision process to predict breast biopsy outcomes from BI-RADS findings. An intelligible reasoning process is an important requirement for the acceptance of CAD systems by physicians. The first approach induces a global model based on decison-tree learning. The second approach is based on case-based reasoning and applies an entropic similarity measure. We have evaluated the performance of both CAD approaches on two large publicly available mammography reference databases using receiver operating characteristic (ROC) analysis, bootstrap sampling, and the ANOVA statistical significance test. Both approaches outperform the diagnosis decisions of the physicians. Hence, both systems have the potential to reduce the number of unnecessary breast biopsies in clinical practice. A comparison of the performance of the proposed decision tree and CBR approaches with a state of the art approach based on artificial neural networks (ANN) shows that the CBR approach performs slightly better than the ANN approach, which in turn results in slightly better performance than the decision-tree approach. The differences are statistically significant (p value <0.001). On 2100 masses extracted from the DDSM database, the CRB approach for example resulted in an area under the ROC curve of A(z)=0.89±0.01, the decision-tree approach in A(z)=0.87±0

  4. TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Hoffman, J; Kim, H; Hsu, W; Flores, C; Lee, G; Brown, M; McNitt-Gray, M

    2016-01-01

    Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens

  5. TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Hoffman, J; Kim, H; Hsu, W; Flores, C; Lee, G; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens

  6. Mark II magnetic detector for SPEAR

    International Nuclear Information System (INIS)

    Larsen, R.R.

    1975-01-01

    The Mark II Detector, presently in the design stage, is a SLAC/LBL detector project to replace the Mark I now in operation at SPEAR. While similar in concept to the Mark I it will have improved momentum resolution, shower detection, solid angle coverage for both triggering and tracking and a magnet design providing easier access to those particles transmitted through the aluminum coil

  7. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening

    DEFF Research Database (Denmark)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR......) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were...... excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences...

  8. Fatigue resistance of 2 different CAD/CAM glass-ceramic materials used for single-tooth implant crowns.

    Science.gov (United States)

    Çavuşoğlu, Yeliz; Sahin, Erdal; Gürbüz, Riza; Akça, Kivanç

    2011-10-01

    To evaluate the fatigue resistance of 2 different CAD/CAM in-office monoceramic materials with single-tooth implant-supported crowns in functional area. A metal experimental model with a dental implant was designed to receive in-office CAD/CAM-generated monoceramic crowns. Laterally positioned axial dynamic loading of 300 N at 2 Hz was applied to implant-supported crowns machined from 2 different glass materials for 100,000 cycle. Failures in terms of fracture, crack formation, and chipping were macroscopically recorded and microscopically evaluated. Four of 10 aluminasilicate glass-ceramic crowns fractured at early loading cycles, the rest completed loading with a visible crack formation. Crack formation was recorded for 2 of 10 leucite glass-ceramic crowns. Others completed test without visible damage but fractured upon removal. Lack in chemical adhesion between titanium abutment and dental cement likely reduces the fatigue resistance of machinable glass-ceramic materials. However, relatively better fractural strength of leucite glass-ceramics could be taken into consideration. Accordingly, progress on developmental changes in filler composition of glass-ceramics may be promising. Machinable glass-ceramics do not possess sufficient fatigue resistance for single-tooth implant crowns in functional area.

  9. Process and Tool Innovation for CAD Integration with OLTARIS, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA uses computer aided design (CAD) capabilities to produce space vehicle designs. One aspect of the vehicle design is utilizing enough shielding to minimize dose...

  10. Process and Tool Innovation for CAD Integration with OLTARIS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA uses computer aided design (CAD) capabilities to produce space vehicle designs. One aspect of the vehicle design is utilizing enough shielding to minimize dose...

  11. rCAD: A Novel Database Schema for the Comparative Analysis of RNA.

    Science.gov (United States)

    Ozer, Stuart; Doshi, Kishore J; Xu, Weijia; Gutell, Robin R

    2011-12-31

    Beyond its direct involvement in protein synthesis with mRNA, tRNA, and rRNA, RNA is now being appreciated for its significance in the overall metabolism and regulation of the cell. Comparative analysis has been very effective in the identification and characterization of RNA molecules, including the accurate prediction of their secondary structure. We are developing an integrative scalable data management and analysis system, the RNA Comparative Analysis Database (rCAD), implemented with SQL Server to support RNA comparative analysis. The platformagnostic database schema of rCAD captures the essential relationships between the different dimensions of information for RNA comparative analysis datasets. The rCAD implementation enables a variety of comparative analysis manipulations with multiple integrated data dimensions for advanced RNA comparative analysis workflows. In this paper, we describe details of the rCAD schema design and illustrate its usefulness with two usage scenarios.

  12. CAD/CAM/CAI Application for High-Precision Machining of Internal Combustion Engine Pistons

    Directory of Open Access Journals (Sweden)

    V. V. Postnov

    2014-07-01

    Full Text Available CAD/CAM/CAI application solutions for internal combustion engine pistons machining was analyzed. Low-volume technology of internal combustion engine pistons production was proposed. Fixture for CNC turning center was designed.

  13. Building of a CAD system for instrumentation and control system of nuclear power plant

    International Nuclear Information System (INIS)

    Ma Zhicai; Hu Chunping; Zhang Dongsheng

    2012-01-01

    Base on the analysis of deign documents and process, a database for instrumentation and control system design can be developed with a popular desktop relational database management system (RDBMS). With the RDBMS, an instrumentation and control system CAD system can be built unitizing database link feature of popular CAD software, with the function of management of design data, output of list and forms. and design of drawings. A CAD system of this kind has been used in the design practice of nuclear power plant. With this system, it is shown that, the consistency of information has been controlled and the load on the engineer has been significantly reduced. The methodology used here can also be used in the CAD system for CAP1000 and CAP1400 plant. (authors) series

  14. DESIGN REVIEW OF CAD MODELS USING A NUI LEAP MOTION SENSOR

    Directory of Open Access Journals (Sweden)

    GÎRBACIA Florin

    2015-06-01

    Full Text Available Natural User Interfaces (NUI is a relatively new area of research that aims to develop humancomputer interfaces, natural and intuitive, using voice commands, hand movements and gesture recognition, similar to communication between people which also implies body language and gestures. In this paper is presented a natural designed workspace which acquires the user's motion using a Leap Motion sensor and visualizes the CAD models using a CAVE-like 3D visualisation system. The user can modify complex CAD models using bimanual gesture commands in a 3D virtual environment. The developed bimanual gestures for rotate, pan, zoom and explode are presented. From the conducted experiments is established that Leap Motion NUI sensor provides an intuitive tool for design review of CAD models, performed even by users with no experience in CAD systems and virtual environments.

  15. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  16. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  17. Evaluation of Shipbuilding CAD/CAM/CIM Systems - Phase II (Requirements for Future Systems)

    National Research Council Canada - National Science Library

    Horvath, John; Ross, Jonathan M

    1997-01-01

    .... The purpose of the analysis was two fold: 1. To describe the requirements of a competitive, future-oriented computer-aided design/computer-aided manufacturing/computer-integrated management (CAD/CAMYCIM...

  18. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  19. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    Science.gov (United States)

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p CAD/CAM PMMA-based M (p CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  20. The building and application of a flexible CAD model for the DTU ECOCAR

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    A flexible surface model is required for CFD-optimization of the DTU ECOCAR. The report exemplifies the creation of such a model using the 3D CAD system Creo 3.0 Parametric.......A flexible surface model is required for CFD-optimization of the DTU ECOCAR. The report exemplifies the creation of such a model using the 3D CAD system Creo 3.0 Parametric....

  1. Evolution of facility layout requirements and CAD [computer-aided design] system development

    International Nuclear Information System (INIS)

    Jones, M.

    1990-06-01

    The overall configuration of the Superconducting Super Collider (SSC) including the infrastructure and land boundary requirements were developed using a computer-aided design (CAD) system. The evolution of the facility layout requirements and the use of the CAD system are discussed. The emphasis has been on minimizing the amount of input required and maximizing the speed by which the output may be obtained. The computer system used to store the data is also described

  2. Analysis of HOM Problems in the C-ADS Main Linac

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Burn [Chinese Academy of Sciences (CAS), Lanzhou (China). Inst. of Modern Physics; Ng, King Yuen [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-05-18

    Excitation of higher-order modes (HOMs) in superconducting cavities may severely affect the operation of the main linac in the Chinese Accelerator Driven System (CADS). Preliminary analysis is made on the effects of beam dynamic, which includes possible longitudinal and transverse emittance enlargements, as well as the possibility of beam breakup. Suggestions are given for further investigation. Comparison is made between the C-ADS and the Fermilab Project X.

  3. CAD-based automatic modeling method for Geant4 geometry model through MCAM

    International Nuclear Information System (INIS)

    Wang, D.; Nie, F.; Wang, G.; Long, P.; LV, Z.

    2013-01-01

    The full text of publication follows. Geant4 is a widely used Monte Carlo transport simulation package. Before calculating using Geant4, the calculation model need be established which could be described by using Geometry Description Markup Language (GDML) or C++ language. However, it is time-consuming and error-prone to manually describe the models by GDML. Automatic modeling methods have been developed recently, but there are some problems that exist in most present modeling programs, specially some of them were not accurate or adapted to specifically CAD format. To convert the GDML format models to CAD format accurately, a Geant4 Computer Aided Design (CAD) based modeling method was developed for automatically converting complex CAD geometry model into GDML geometry model. The essence of this method was dealing with CAD model represented with boundary representation (B-REP) and GDML model represented with constructive solid geometry (CSG). At first, CAD model was decomposed to several simple solids which had only one close shell. And then the simple solid was decomposed to convex shell set. Then corresponding GDML convex basic solids were generated by the boundary surfaces getting from the topological characteristic of a convex shell. After the generation of these solids, GDML model was accomplished with series boolean operations. This method was adopted in CAD/Image-based Automatic Modeling Program for Neutronics and Radiation Transport (MCAM), and tested with several models including the examples in Geant4 install package. The results showed that this method could convert standard CAD model accurately, and can be used for Geant4 automatic modeling. (authors)

  4. CADS: a FORTRAN subroutine package to aid symbolic dataflow in FORTRAN programs

    International Nuclear Information System (INIS)

    Richards, L.R.P.; Butland, A.T.D.; Symonds, A.G.

    1982-07-01

    The Core Allocation and Dataflow System, CADS, consists of two parts, VARY and VARYIO. VARY provides a means of organising the use of data store in a program by allowing the programmer to reference and manipulate areas of data store by names of the programmer's subprogram, and therefore the complete program, to be independent of its data sources or the destination of its results. CADS therefore provides a system of symbolic dataflow. (author)

  5. The modular technology of development of the CAD expansions: protection of the buildings from the lightning

    OpenAIRE

    Migunov, Vladimir V.; Kafiyatullov, Rustem R.; Safin, Ilsur T.

    2004-01-01

    The modular technology of development of the problem-oriented CAD expansions is applied to a task of designing of protection of the buildings from the lightning with realization in program system TechnoCAD GlassX. The system model of the drawings of lightning protection is developed including the structured parametric representation (properties of objects and their interdependence, general settings and default settings) and operations with it, which efficiently automate designing

  6. Recognition in context: Implications for trade mark law.

    Science.gov (United States)

    Humphreys, Michael S; McFarlane, Kimberley A; Burt, Jennifer S; Kelly, Sarah J; Weatherall, Kimberlee G; Burrell, Robert G

    2017-10-01

    Context effects in recognition have played a major role in evaluating theories of recognition. Understanding how context impacts recognition is also important for making sound trade mark law. Consumers attempting to discriminate between the brand they are looking for and a look-alike product often have to differentiate products which share a great deal of common context: positioning on the supermarket shelf, the type of store, aspects of the packaging, or brand claims. Trade mark and related laws aim to protect brands and reduce consumer confusion, but courts assessing allegations of trade mark infringement often lack careful empirical evidence concerning the impact of brand and context similarity, and, in the absence of such evidence, make assumptions about how consumers respond to brands that downplay the importance of context and focus on the similarity of registered marks. The experiments reported in this paper aimed to test certain common assumptions in trade mark law, providing evidence that shared context can cause mistakes even where brand similarity is low.

  7. Geological modeling of a stratified deposit with CAD-Based solid model automation

    Directory of Open Access Journals (Sweden)

    Ayten Eser

    Full Text Available Abstract The planning stages of mining activities require many comprehensive and detailed analyses. Determining the correct orebody model is the first stage and one of the most important. Three-dimensional solid modeling is one of the significant methods that can examine the position and shape of the ore deposit. Although there are many different types of mining software for determining a solid model, many users try to build geological models in the computer without knowing how these software packages work. As researchers on the subject, we wanted to answer the question "How would we do it". For this purpose, a system was developed for generating solid models using data obtained from boreholes. Obtaining this model in an AutoCAD environment will be important for geologists and engineers. Developed programs were first tested with virtual borehole data belonging to a virtual deposit. Then the real borehole data of a cement raw material site were successfully applied. This article allows readers not only to see a clear example of the programming approach to layered deposits but also to produce more complicated software in this context. Our study serves as a window to understanding the geological modeling process.

  8. INTEGRATION OF VIDEO IMAGES AND CAD WIREFRAMES FOR 3D OBJECT LOCALIZATION

    Directory of Open Access Journals (Sweden)

    R. A. Persad

    2012-07-01

    Full Text Available The tracking of moving objects from single images has received widespread attention in photogrammetric computer vision and considered to be at a state of maturity. This paper presents a model-driven solution for localizing moving objects detected from monocular, rotating and zooming video images in a 3D reference frame. To realize such a system, the recovery of 2D to 3D projection parameters is essential. Automatic estimation of these parameters is critical, particularly for pan-tilt-zoom (PTZ surveillance cameras where parameters change spontaneously upon camera motion. In this work, an algorithm for automated parameter retrieval is proposed. This is achieved by matching linear features between incoming images from video sequences and simple geometric 3D CAD wireframe models of man-made structures. The feature matching schema uses a hypothesis-verify optimization framework referred to as LR-RANSAC. This novel method improves the computational efficiency of the matching process in comparison to the standard RANSAC robust estimator. To demonstrate the applicability and performance of the method, experiments have been performed on indoor and outdoor image sequences under varying conditions with lighting changes and occlusions. Reliability of the matching algorithm has been analyzed by comparing the automatically determined camera parameters with ground truth (GT. Dependability of the retrieved parameters for 3D localization has also been assessed by comparing the difference between 3D positions of moving image objects estimated using the LR-RANSAC-derived parameters and those computed using GT parameters.

  9. Structural Insight into the Core of CAD, the Multifunctional Protein Leading De Novo Pyrimidine Biosynthesis.

    Science.gov (United States)

    Moreno-Morcillo, María; Grande-García, Araceli; Ruiz-Ramos, Alba; Del Caño-Ochoa, Francisco; Boskovic, Jasminka; Ramón-Maiques, Santiago

    2017-06-06

    CAD, the multifunctional protein initiating and controlling de novo biosynthesis of pyrimidines in animals, self-assembles into ∼1.5 MDa hexamers. The structures of the dihydroorotase (DHO) and aspartate transcarbamoylase (ATC) domains of human CAD have been previously determined, but we lack information on how these domains associate and interact with the rest of CAD forming a multienzymatic unit. Here, we prove that a construct covering human DHO and ATC oligomerizes as a dimer of trimers and that this arrangement is conserved in CAD-like from fungi, which holds an inactive DHO-like domain. The crystal structures of the ATC trimer and DHO-like dimer from the fungus Chaetomium thermophilum confirm the similarity with the human CAD homologs. These results demonstrate that, despite being inactive, the fungal DHO-like domain has a conserved structural function. We propose a model that sets the DHO and ATC complex as the central element in the architecture of CAD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  11. Design Automation Using Script Languages. High-Level CAD Templates in Non-Parametric Programs

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study the advantages offered by the application of traditional techniques of technical drawing in processes for automation of the design, with non-parametric CAD programs, provided with scripting languages. Given that an example drawing can be solved with traditional step-by-step detailed procedures, is possible to do the same with CAD applications and to generalize it later, incorporating references. In today’s modern CAD applications, there are striking absences of solutions for building engineering: oblique projections (military and cavalier), 3D modelling of complex stairs, roofs, furniture, and so on. The use of geometric references (using variables in script languages) and their incorporation into high-level CAD templates allows the automation of processes. Instead of repeatedly creating similar designs or modifying their data, users should be able to use these templates to generate future variations of the same design. This paper presents the automation process of several complex drawing examples based on CAD script files aided with parametric geometry calculation tools. The proposed method allows us to solve complex geometry designs not currently incorporated in the current CAD applications and to subsequently create other new derivatives without user intervention. Automation in the generation of complex designs not only saves time but also increases the quality of the presentations and reduces the possibility of human errors.

  12. Format conversion between CAD data and GIS data based on ArcGIS

    Science.gov (United States)

    Xie, Qingqing; Wei, Bo; Zhang, Kailin; Wang, Zhichao

    2015-12-01

    To make full use of the data resources and realize a sharing for the different types of data in different industries, a method of format conversion between CAD data and GIS data based on ArcGIS was proposed. To keep the integrity of the converted data, some key steps to process CAD data before conversion were made in AutoCAD. For examples, deleting unnecessary elements such as title, border and legend avoided the appearance of unnecessary elements after conversion, as layering data again by a national standard avoided the different types of elements to appear in a same layer after conversion. In ArcGIS, converting CAD data to GIS data was executed by the correspondence of graphic element classification between AutoCAD and ArcGIS. In addition, an empty geographic database and feature set was required to create in ArcGIS for storing the text data of CAD data. The experimental results show that the proposed method avoids a large amount of editing work in data conversion and maintains the integrity of spatial data and attribute data between before and after conversion.

  13. Progress of conversion system from CAD data to MCNP geometry data in Japan

    International Nuclear Information System (INIS)

    Sato, S.; Nashif, H.; Masuda, F.; Morota, H.; Iida, H.; Konno, C.

    2010-01-01

    Automatic conversion systems from CAD data to MCNP geometry input data have been developed to convert the CAD data of the fusion reactor with very complicated structure. So far, two conversion systems (GEOMIT-1 and ARCMCP) have been developed and the third system (GEOMIT-2) is under developing. The void data can be created in these systems. GEOMIT-1 was developed in 2007, but a lot of manual shape splitting work for the CAD data was required to convert the complicated geometry. ARCMCP was developed in 2008. The algorithm has been drastically improved on automatic creation of ambiguous surface in ARCMCP, but it still required a little manual shape splitting work. The latest system, GEOMIT-2, does not require additional commercial software packages, though the previous systems require them. It also has functions of the CAD data healing and the automatic shape splitting. Geometrical errors of CAD data can be automatically revised by the healing function, and complicated geometries can be automatically split into simple geometries by the shape splitting function. Any manual works for CAD data are not required in GEOMIT-2. GEOMIT-2 is very useful for nuclear analyses of fusion reactors.

  14. A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas

    Science.gov (United States)

    Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.

    2007-03-01

    Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.

  15. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  16. 49 CFR 1520.13 - Marking SSI.

    Science.gov (United States)

    2010-10-01

    ... SECURITY INFORMATION § 1520.13 Marking SSI. (a) Marking of paper records. In the case of paper records... back cover, including a binder cover or folder, if the document has a front and back cover; (2) Any.... 552 and 49 CFR parts 15 and 1520. (d) Other types of records. In the case of non-paper records that...

  17. Lessons learned : pavement marking warranty contract.

    Science.gov (United States)

    2013-12-01

    In 2012, UDOT implemented a performance-based warranty on a portion of an I-15 pavement marking : project. The awarded contract requested a contractor warranty on the implemented markings for a total : duration of six years. This is the first time th...

  18. 49 CFR 178.338-18 - Marking.

    Science.gov (United States)

    2010-10-01

    ... pounds. (7) Maximum design density of lading (Max. Lading density), in pounds per gallon. (8) Material... cryogenic liquid, in hours, and the name of that cryogenic liquid (MRHT __ hrs, name of cryogenic liquid). Marked rated holding marking for additional cryogenic liquids may be displayed on or adjacent to the...

  19. 25 CFR 141.16 - Price marking.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Price marking. 141.16 Section 141.16 Indians BUREAU OF... AND ZUNI RESERVATIONS General Business Practices § 141.16 Price marking. The price of each article... visible to the customer and that affords the customer a reasonable opportunity to learn the price of the...

  20. Do employers prefer Mark over Mohammed?

    NARCIS (Netherlands)

    Iris Andriessen; Eline Nievers; Laila Faulk; Jaco Dagevos

    2010-01-01

    Original title: Liever Mark dan Mohammed? Does Mohammed have less chance of succeeding on the Dutch labour market than Mark, even though they both have the same qualifications and work experience? And are employers less friendly towards Sonaya than Paula? This study investigates the

  1. 7 CFR 956.162 - Container markings.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Container markings. 956.162 Section 956.162... WALLA VALLEY OF SOUTHEAST WASHINGTON AND NORTHEAST OREGON Rules and Regulations § 956.162 Container markings. Effective April 15, 1997, no handler shall ship any container of Walla Walla Sweet Onions except...

  2. Cadências escolares, ritmos docentes School cadences, teaching rhythms

    Directory of Open Access Journals (Sweden)

    Inês Assunção de Castro Teixeira

    1999-07-01

    Full Text Available O artigo analisa alguns dos eixos que estruturam os ritmos cotidianos dos professores, próprios às temporalidades da vida social na escola. Parte do pressuposto de que o tempo é uma "categoria do pensamento lógico", originada no ritmo da vida social (Dukheim, e que essa rítmica é uma "modalidade concreta do tempo social" (Lefebvre e Régulier. O estudo é parte de uma pesquisa que busca tematizar a experiência do tempo de sujeitos que se encontram na condição de professores - docentes de quinta à oitava séries do ensino fundamental e do ensino médio -, levando em conta seus vínculos com a construção de identidades docentes. O texto se desenvolve em torno de três eixos: as cadências das interações entre educandos e educadores, os ritmos dos calendários e os compassos dos horários escolares. Conclui-se que os ritmos docentes, embora circunscritos à rítmica da vida moderna, têm particularidades associadas às cadências da escola, aos processos pedagógicos e àqueles relacionados à formação humana. Trata-se, pois, de analisar a polirritmia dos tempos da escola em sua complexidade e peculiaridades, de forma a se compreenderem as modulações e significações da experiência do tempo na condição de professor, vivência constitutiva das identidades docentes.This paper analyzes some of the concepts peculiar to the temporality of the school social life that structure the everyday rhythm of teachers. It assumes that time is a "category of logical thinking" originated in the rhythm of social life (Durkheim, and that such rhythmic character is a "concrete modality of social time" (Lefebvre and Régulier. This study is part of a research that seeks to discuss the experience of time for teachers of the 5th to 8th grades of the Primary Education and of the Secondary Education, taking into account the teachers’ links with the construction of their own teaching identities. The text is developed around three themes: the cadences

  3. Advances in computer-aided engineering : CAD/CAM-research at Delft University of Technology. Report of the VF-project CAD/CAM 1989-1994

    NARCIS (Netherlands)

    Undetermined, U.

    1994-01-01

    This book contains a collection of articles describing on-going CAD/CAM-research at several engineering faculties at Delft University of Technology. Two main themes covered in this book are 'Conceptual design of complex products' and 'Product modelling and product data exchange'.

  4. High contrast laser marking of alumina

    Science.gov (United States)

    Penide, J.; Quintero, F.; Riveiro, A.; Fernández, A.; del Val, J.; Comesaña, R.; Lusquiños, F.; Pou, J.

    2015-05-01

    Alumina serves as raw material for a broad range of advanced ceramic products. These elements should usually be identified by some characters or symbols printed directly on them. In this sense, laser marking is an efficient, reliable and widely implemented process in industry. However, laser marking of alumina still leads to poor results since the process is not able to produce a dark mark, yielding bad contrast. In this paper, we present an experimental study on the process of marking alumina by three different lasers working in two wavelengths: 1064 nm (Near-infrared) and 532 nm (visible, green radiation). A colorimetric analysis has been carried out in order to compare the resulting marks and its contrast. The most suitable laser operating conditions were also defined and are reported here. Moreover, the physical process of marking by NIR lasers is discussed in detail. Field Emission Scanning Electron Microscopy, High Resolution Transmission Electron Microscopy and X-ray Photoelectron Spectroscopy were also employed to analyze the results. Finally, we propose an explanation for the differences of the coloration induced under different atmospheres and laser parameters. We concluded that the atmosphere is the key parameter, being the inert one the best choice to produce the darkest marks.

  5. Court presentation of bite mark evidence.

    Science.gov (United States)

    Drinnan, A J; Melton, M J

    1985-12-01

    The uniqueness of an individual's bite mark is generally accepted. The use of bite mark analysis to identify or exclude those suspected of crimes is now a well established activity in forensic dentistry. Although the techniques for evaluating bite mark evidence are extremely sophisticated, it is important that the courtroom presentation of such evidence should be as simple as possible and be directed towards those who must judge it. Dentists likely to be involved in the courtroom presentation of bite mark evidence should: be certain that their local law enforcement personnel are frequently updated on the techniques to be used for producing the optimum evidence needed to evaluate bite marks; become acquainted with the current techniques of evaluating bite mark evidence and understand their difficulties and pitfalls; meet with the lawyers (prosecution or defence) before a courtroom appearance, briefing them on the significance of the particular findings; prepare clear and easily understandable visual aids to present to the court the techniques used in the analysis and the bases for the conclusion reached; and offer conclusions derived from the bite mark investigation.

  6. Changing Context of Trade Mark Protection in India: A Review of the Trade Marks Act, 1999

    OpenAIRE

    Pathak, Akhileshwar

    2004-01-01

    With liberalisation and globalisation of the Indian economy, it has become possible for anyone to get into production and services in most of the sectors. This has led to rampant misuse and appropriation of trade marks. In an insulated economy, with monopoly markets, law protecting trade marks had a limited role. In the changed context, however, trade mark law will be a field of much interest for academics and practitioners. Towards this, the paper explores the formation of trade mark law in ...

  7. Elemental marking of arthropod pests in agricultural systems: single and multigenerational marking

    Science.gov (United States)

    Jane Leslie Hayes

    1991-01-01

    Use of elemental markers to study movement of arthropod pests of field crops is reviewed. Trace elements, rubidium (Rb) and cesium (Cs), have provided a nondisruptive method of marking natural adult populations via developmental stage consumption of treated host plants. Multigenerational marking occurs with the transfer of elemental markers from marked adults to...

  8. Comparison of the reference mark azimuth determination methods

    Directory of Open Access Journals (Sweden)

    Danijel Šugar

    2013-03-01

    Full Text Available The knowledge of the azimuth of the reference mark is of crucial importance in the determination of the declination which is defined as the ellipsoidal (geodetic azimuth of the geomagnetic meridian. The accuracy of the azimuth determination has direct impact on the accuracy of the declination. The orientation of the Declination-Inclination Magnetometer is usually carried out by sighting the reference mark in two telescope faces in order to improve the reliability of the observations and eliminate some instrumental errors. In this paper, different coordinate as well as azimuth determination methods using GNSS (Global Navigation Satellite System observation techniques within VPPS (High-Precision Positioning Service and GPPS (Geodetic-Precision Positioning Service services of the CROPOS (CROatian POsitioning System system were explained. The azimuth determination by the observation of the Polaris was exposed and it was subsequently compared with the observation of the Sun using hour-angle and zenith-distance method. The procedure of the calculation of the geodetic azimuth from the astronomic azimuth was explained. The azimuth results obtained by different methods were compared and the recommendations on the minimal distance between repeat station and azimuth mark were given. The results shown in this paper were based on the observations taken on the POKU_SV repeat station.

  9. Variation in CAD Secondary Prevention Prescription among Outpatient Cardiology Practices: Insights from the NCDR®

    Science.gov (United States)

    Maddox, Thomas M.; Chan, Paul S.; Spertus, John A.; Tang, Fengming; Jones, Phil; Ho, P. Michael; Bradley, Steven M.; Tsai, Thomas T.; Bhatt, Deepak L.; Peterson, Pamela N.

    2014-01-01

    Objectives This study assesses practice variation of secondary prevention medication prescription among coronary artery disease (CAD) patients treated in outpatient practices participating in the NCDR® PINNACLE Registry®. Background Among patients with CAD, secondary prevention with a combination of beta-blockers, angiotensin converting enzyme inhibitors/angiotensin receptor blockers, and statins reduces cardiac mortality and myocardial infarction (MI). Accordingly, every CAD patient should receive the combination of these medications for which they are eligible. However, little is known about current prescription patterns of these medications and the variation in use among outpatient cardiology clinics. Methods Using data from NCDR® PINNACLE Registry®, a national outpatient cardiology practice registry, we assessed medication prescription patterns among eligible CAD patients between July 2008 and December 2010. Overall rates of prescription and variation by practice were calculated, adjusting for patient characteristics. Results Among 156,145 CAD patients in 58 practices, 103,830 (66.5%) were prescribed the optimal combination of medications for which they were eligible. The median rate of optimal combined prescription by practice was 73.5% and varied from 28.8% to 100%. After adjustment for patient factors, the practice median rate ratio for prescription was 1.25 (95% CI 1.2,1.32), indicating a 25% likelihood that 2 random practices would differ in treating identical CAD patients. Conclusions Among a national registry of CAD patients treated in outpatient cardiology practices, over one-third of patients failed to receive their optimal combination of secondary prevention medications. Significant variation was observed across practices, even after adjusting for patient characteristics, suggesting that quality improvement efforts may be needed to support more uniform practice. PMID:24184238

  10. Quantitative assessment of multiple sclerosis lesion load using CAD and expert input

    Science.gov (United States)

    Gertych, Arkadiusz; Wong, Alexis; Sangnil, Alan; Liu, Brent J.

    2008-03-01

    Multiple sclerosis (MS) is a frequently encountered neurological disease with a progressive but variable course affecting the central nervous system. Outline-based lesion quantification in the assessment of lesion load (LL) performed on magnetic resonance (MR) images is clinically useful and provides information about the development and change reflecting overall disease burden. Methods of LL assessment that rely on human input are tedious, have higher intra- and inter-observer variability and are more time-consuming than computerized automatic (CAD) techniques. At present it seems that methods based on human lesion identification preceded by non-interactive outlining by CAD are the best LL quantification strategies. We have developed a CAD that automatically quantifies MS lesions, displays 3-D lesion map and appends radiological findings to original images according to current DICOM standard. CAD is also capable to display and track changes and make comparison between patient's separate MRI studies to determine disease progression. The findings are exported to a separate imaging tool for review and final approval by expert. Capturing and standardized archiving of manual contours is also implemented. Similarity coefficients calculated from quantities of LL in collected exams show a good correlation of CAD-derived results vs. those incorporated as expert's reading. Combining the CAD approach with an expert interaction may impact to the diagnostic work-up of MS patients because of improved reproducibility in LL assessment and reduced time for single MR or comparative exams reading. Inclusion of CAD-generated outlines as DICOM-compliant overlays into the image data can serve as a better reference in MS progression tracking.

  11. First results from Mark III at SPEAR

    International Nuclear Information System (INIS)

    Einsweiler, K.F.

    The paper presents data on meson decays obtained using the MARK III detector operating at SPEAR. Results on hadronic decays; decays of the etasub(e); and results on radiative decays; are all described. (U.K.)

  12. User's guide : pavement marking management system database.

    Science.gov (United States)

    2011-12-01

    Pavement markings play a critical role in maintaining a safe and efficient driving environment for road users, especially during nighttime conditions. The Texas Department of Transportation (TxDOT) spends millions of dollars each year for installatio...

  13. Mark Twain, Fenimore Cooper, and Batman.

    Science.gov (United States)

    Crick, Robert Alan

    1992-01-01

    Describes how Mark Twain's essay "Fenimore Cooper's Literary Offenses" helped students to get interested in writing and inspired them to write a similar essay critiquing the movie "Batman." Provides excerpts from students' essays. (PRA)

  14. 46 CFR 160.054-6 - Marking.

    Science.gov (United States)

    2010-10-01

    ... “To Close, Press Together Full Length”. The marking may be applied to the container by the silk screen process, using a suitable ink or paint, or may be applied by other means shown to be acceptable. (b...

  15. 49 CFR 180.213 - Requalification markings.

    Science.gov (United States)

    2010-10-01

    ... eddy current examination combined with a visual inspection, the marking is as illustrated in paragraph..., securely affixed in a manner prescribed by the cylinder manufacturer, near the original manufacturer's...

  16. Microscopic saw mark analysis: an empirical approach.

    Science.gov (United States)

    Love, Jennifer C; Derrick, Sharon M; Wiersema, Jason M; Peters, Charles

    2015-01-01

    Microscopic saw mark analysis is a well published and generally accepted qualitative analytical method. However, little research has focused on identifying and mitigating potential sources of error associated with the method. The presented study proposes the use of classification trees and random forest classifiers as an optimal, statistically sound approach to mitigate the potential for error of variability and outcome error in microscopic saw mark analysis. The statistical model was applied to 58 experimental saw marks created with four types of saws. The saw marks were made in fresh human femurs obtained through anatomical gift and were analyzed using a Keyence digital microscope. The statistical approach weighed the variables based on discriminatory value and produced decision trees with an associated outcome error rate of 8.62-17.82%. © 2014 American Academy of Forensic Sciences.

  17. Enamel-based mark performance for marking Chinese mystery snail Bellamya chinensis

    Science.gov (United States)

    Wong, Alec; Allen, Craig R.; Hart, Noelle M.; Haak, Danielle M.; Pope, Kevin L.; Smeenk, Nicholas A.; Stephen, Bruce J.; Uden, Daniel R.

    2013-01-01

    The exoskeleton of gastropods provides a convenient surface for carrying marks, and i the interest of improving future marking methods our laboratory assessed the performance of an enamel paint. The endurance of the paint was also compared to other marking methods assessed in the past. We marked the shells of 30 adult Chinese mystery snails Bellamya chinensis and held them in an aquarium for 181 days. We observed no complete degradation of any enamel-paint mark during the 181 days. The enamel-paint mark was superior to a nai;-polish mark, which lasted a median of 100 days. Enamel-paint marks also have a lower rate of loss (0.00 month-1 181 days) than plastic bee tags (0.01 month-1, 57 days), gouache paint (0.07 month-1, 18.5 days), or car body paint from studies found in scientific literature. Legibility of enamel-paint marks had a median lifetime of 102 days. The use of enamel paint on the shells of gastropods is a viable option for studies lasting up to 6 months. Furthermore, visits to capture-mark-recapture site 1 year after application of enamel-paint marks on B. chinesnis shells produced several individuals on which the enamel paint was still visible, although further testing is required to clarify durability over longer periods.

  18. PREOPERATIVE ENDOSCOPIC MARKING OF UNPALPABLE COLONIC TUMORS

    Directory of Open Access Journals (Sweden)

    A. L. Goncharov

    2013-01-01

    Full Text Available The identification of small colon lesions is one of the major problems in laparoscopic colonic resection.Research objective: to develop a technique of visualization of small tumors of a colon by preoperative endoscopic marking of a tumor.Materials and methods. In one day prior to operation to the patient after bowel preparation the colonoscopy is carried out. In the planned point near tumor on antimesentery edge the submucous infiltration of marking solution (Micky Sharpz blue tattoo pigment, UK is made. The volume of entered solution of 1–3 ml. In only 5 months of use of a technique preoperative marking to 14 patients with small (the size of 1–3 cm malignant tumors of the left colon is performed.Results. The tattoo mark was well visualized by during operation at 13 of 14 patients. In all cases we recorded no complications. Time of operation with preoperative marking averaged 108 min, that is significantly less in comparison with average time of operation with an intra-operative colonoscopy – 155 min (р < 0.001.Conclusions. The first experience of preoperative endoscopic marking of non palpable small tumors of a colon is encouraging. Performance of a technique wasn't accompanied by complications and allowed to reduce significantly time of operation and to simplify conditions of performance of operation.

  19. Detection and function of an intramolecular disulfide bond in the pH-responsive CadC of Escherichia coli

    Directory of Open Access Journals (Sweden)

    Dönhöfer Alexandra

    2011-04-01

    Full Text Available Abstract Background In an acidic and lysine-rich environment Escherichia coli induces expression of the cadBA operon which encodes CadA, the lysine decarboxylase, and CadB, the lysine/cadaverine antiporter. cadBA expression is dependent on CadC, a membrane-integrated transcriptional activator which belongs to the ToxR-like protein family. Activation of CadC requires two stimuli, lysine and low pH. Whereas lysine is detected by an interplay between CadC and the lysine-specific transporter LysP, pH alterations are sensed by CadC directly. Crystal structural analyses revealed a close proximity between two periplasmic cysteines, Cys208 and Cys272. Results Substitution of Cys208 and/or Cys272 by alanine resulted in CadC derivatives that were active in response to only one stimulus, either lysine or pH 5.8. Differential in vivo thiol trapping revealed a disulfide bond between these two residues at pH 7.6, but not at pH 5.8. When Cys208 and Cys272 were replaced by aspartate and lysine, respectively, virtually wild-type behavior was restored indicating that the disulfide bond could be mimicked by a salt bridge. Conclusion A disulfide bond was found in the periplasmic domain of CadC that supports an inactive state of CadC at pH 7.6. At pH 5.8 disulfide bond formation is prevented which transforms CadC into a semi-active state. These results provide new insights into the function of a pH sensor.

  20. An Analysis of Computer Aided Design (CAD) Packages Used at MSFC for the Recent Initiative to Integrate Engineering Activities

    Science.gov (United States)

    Smith, Leigh M.; Parker, Nelson C. (Technical Monitor)

    2002-01-01

    This paper analyzes the use of Computer Aided Design (CAD) packages at NASA's Marshall Space Flight Center (MSFC). It examines the effectiveness of recent efforts to standardize CAD practices across MSFC engineering activities. An assessment of the roles played by management, designers, analysts, and manufacturers in this initiative will be explored. Finally, solutions are presented for better integration of CAD across MSFC in the future.