WorldWideScience

Sample records for positioned unpolarized high

  1. Unpolarized state of light revisited

    International Nuclear Information System (INIS)

    Prakash, H.; Chandra, N.

    1981-04-01

    The general form of probability distribution function of analytic signal for unpolarized light is found using simple classical arguments. It is shown that the concepts of unpolarized light given in some common standard books are, strictly speaking, not correct. It is proved that if any two orthogonally polarized components of unpolarized light are statistically independent of each other, the light is of chaotic nature. (author)

  2. Unpolarized Structure Functions

    International Nuclear Information System (INIS)

    Christy, M.E.; Melnitchouk, W.

    2011-01-01

    Over the past decade measurements of unpolarized structure functions with unprecedented precision have significantly advanced our knowledge of nucleon structure. These have for the first time allowed quantitative tests of the phenomenon of quark-hadron duality, and provided a deeper understanding of the transition from hadron to quark degrees of freedom in inclusive scattering. Dedicated Rosenbluth-separation experiments have yielded high-precision transverse and longitudinal structure functions in regions previously unexplored, and new techniques have enabled the first glimpses of the structure of the free neutron, without contamination from nuclear effects.

  3. Spin physics through unpolarized processes

    Science.gov (United States)

    Lu, Zhun

    2016-02-01

    This article presents a review of our present understanding of the spin structure of the unpolarized hadron. Particular attention is paid to the quark sector at leading twist, namely, the quark Boer-Mulders function, which describes the transverse polarization of the quark inside an unpolarized hadron. After introducing the operator definition of the Boer-Mulders function, a detailed treatment of different non-perturbative calculations of the Boer-Mulders functions is provided. The phenomenology in Drell-Yan processes and semi-inclusive leptoproduction, including the extraction of the quark and antiquark Boer-Mulders functions from experimental data, is presented comprehensively. Finally, prospects for future theoretical studies and experimental measurements are presented in brief.

  4. A high throughput liquid crystal light shutter for unpolarized light using polymer polarization gratings

    Science.gov (United States)

    Komanduri, Ravi K.; Lawler, Kris F.; Escuti, Michael J.

    2011-05-01

    We report on a broadband, diffractive, light shutter with the ability to modulate unpolarized light. This polarizer-free approach employs a conventional liquid crystal (LC) switch, combined with broadband Polarization Gratings (PGs) formed with polymer LC materials. The thin-film PGs act as diffractive polarizing beam-splitters, while the LC switch operates on both orthogonal polarization states simultaneously. As an initial experimental proof-of- concept for unpolarized light with +/-7° aperture, we utilize a commercial twisted-nematic LC switch and our own polymer PGs to achieve a peak transmittance of 80% and peak contrast ratio of 230:1. We characterize the optoelectronic performance, discuss the limitations, and evaluate its use in potential nonmechanical shutter applications (imaging and non-imaging).

  5. Definition and density operator for unpolarized fermion state

    International Nuclear Information System (INIS)

    Prakash, H.

    1981-04-01

    The unpolarized state of fermions is defined as one which does not change in rotations in the spin space. It is shown that, for a fermion field with a specified value of momentum of particles, the density operator is of the form, rho = (1-2a-b)|0,0> 1 , n 2 > is the occupation number state having occupancies n 1 and n 2 in the two spin modes, and a and b are positive quantities which are less than one and give 1-2a-b>=0. (author)

  6. A first determination of the unpolarized quark TMDs from a global analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bacchetta, Alessandro [INFN, Pavia; Delcarro, Filippo [INFN, Pavia; Pisano, Cristian [INFN Pavia; INFN Cagliari; Radici, Marco [INFN Pavia; Signori, Andrea [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2018-04-01

    Transverse momentum dependent distribution and fragmentation functions of unpolarized quarks inside unpolarized protons are extracted, for the first time, through a simultaneous analysis of semi-inclusive deep-inelastic scattering, Drell-Yan and Z boson hadroproduction processes. This study is performed at leading order in perturbative QCD, with energy scale evolution at the next-to-leading logarithmic accuracy. Moreover, some specific choices are made to deal with low scale evolution around 1 GeV2. Since only data in the low transverse momentum region are considered, no matching to fixed-order calculations at high transverse momentum is needed.

  7. Lepton-pair production and the modified Drell-Yan mechanism in high-energy unpolarized and polarized pp and p anti p collisions

    International Nuclear Information System (INIS)

    Chen, C.K.

    1977-01-01

    A modified Drell-Yan mechanism for inclusive dilepton pair production in hadronic reactions is studied, and the significance of comparing high-energy unpolarized and polarized pp and p anti p collisions is discussed. The required beams are currently proposed at Fermilab and CERN

  8. Second Harmonic Generation of Unpolarized Light

    Science.gov (United States)

    Ding, Changqin; Ulcickas, James R. W.; Deng, Fengyuan; Simpson, Garth J.

    2017-11-01

    A Mueller tensor mathematical framework was applied for predicting and interpreting the second harmonic generation (SHG) produced with an unpolarized fundamental beam. In deep tissue imaging through SHG and multiphoton fluorescence, partial or complete depolarization of the incident light complicates polarization analysis. The proposed framework has the distinct advantage of seamlessly merging the purely polarized theory based on the Jones or Cartesian susceptibility tensors with a more general Mueller tensor framework capable of handling partial depolarized fundamental and/or SHG produced. The predictions of the model are in excellent agreement with experimental measurements of z -cut quartz and mouse tail tendon obtained with polarized and depolarized incident light. The polarization-dependent SHG produced with unpolarized fundamental allowed determination of collagen fiber orientation in agreement with orthogonal methods based on image analysis. This method has the distinct advantage of being immune to birefringence or depolarization of the fundamental beam for structural analysis of tissues.

  9. Measurable distributions of unpolarized neutron decay

    International Nuclear Information System (INIS)

    Glueck, F.

    1992-05-01

    Several two- and one-dimensional distributions of unpolarized free neutron decay are calculated. The results of the order-α model independent radiative correction calculations are tabulated numerically. With these corrections the theoretical distributions become precise enough to make possible the determination of the ratio of the axial-vector to the vector weak coupling constants to a precision of ∼0.001. (author) 39 refs.; 7 tabs

  10. Symmetry breaking effect on determination of polarized and unpolarized parton distributions

    International Nuclear Information System (INIS)

    Arbabifar, F.; Khorramian, Ali N.; Khanpour, H.; Atashbar Tehrani, S.

    2013-01-01

    We perform a new extraction for unpolarized and polarized parton distribution functions considering a flavor decompositions for sea quarks and applying very recent deep inelastic scattering (DIS) and semi inclusive deep inelastic scattering (SIDIS) data in the fixed flavor number scheme (FFNS) framework. In the new symmetry breaking scenario the light quark and antiquark densities are extracted separately and new parametrization forms are determined for them. The heavy flavors contribution, including charm and bottom quarks, are also taken to be account for unpolarized distributions

  11. Generation of 46 W green-light by frequency doubling of 96 W picosecond unpolarized Yb-doped fiber amplifier

    Science.gov (United States)

    Qi, Yaoyao; Yu, Haijuan; Zhang, Jingyuan; Zhang, Ling; He, Chaojian; Lin, Xuechun

    2018-05-01

    We demonstrated a high efficiency and high average power picosecond green light source based on SHG (second harmonic generation) of an unpolarized ytterbium-doped fiber amplifier chain. Using single-pass frequency doubling in two temperature-tuned type-I phase-matching LBO crystals, we were able to generate 46 W, >70 ps pulses at 532 nm from a fundamental beam at 1064 nm, whose output is 96 W, 4.8 μJ, with a repetition frequency of 20 MHz and nearly diffraction limited. The optical conversion efficiency was ∼48% in a highly compact design. To the best of our knowledge, this is the first reported on ps green source through SHG of an unpolarized fiber laser with such a high output and high efficiency.

  12. Partonic transverse motion in unpolarized semi-inclusive deep inelastic scattering processes

    International Nuclear Information System (INIS)

    Boglione, M.; Melis, S.; Prokudin, A.

    2011-01-01

    We analyze the role of partonic transverse motion in unpolarized semi-inclusive deep inelastic scattering processes. Imposing appropriate kinematical conditions, we find some constraints which fix an upper limit to the range of allowed k perpendicular values. We show that, applying these additional requirements on the partonic kinematics, we obtain different results with respect to the usual phenomenological approach based on the Gaussian smearing with analytical integration over an unlimited range of k perpendicular values. These variations are particularly interesting for some observables, like the h > azimuthal modulation of the unpolarized semi-inclusive deep inelastic scattering cross section or the average transverse momentum of the final, detected hadron.

  13. SPIN EFFECTS IN THE FRAGMENTATION OF TRANSVERSELY POLARIZED AND UNPOLARIZED QUARKS

    International Nuclear Information System (INIS)

    ANSELMINO, M.; BOER, D.; DALESIO, U.; MURGIA, F.

    2001-01-01

    We study the fragmentation of a transversely polarized quark into a non-collinear (kperpendicular ≠ 0) spinless hadron and the fragmentation of an unpolarized quark into a non collinear transversely polarized spin 1/2 baryon. These nonperturbative properties are described by spin and kperpendicular dependent fragmentation functions and are revealed in the observation of single spin asymmetries. Recent data on the production of pions in polarized semi-inclusive DIS and long known data on A polarization in unpolarized p-N processes are considered: these new fragmentation functions can describe the experimental results and the single spin effects in the quark fragmentation turn out to be surprisingly large

  14. Direct Probes of Linearly Polarized Gluons inside Unpolarized Hadrons

    NARCIS (Netherlands)

    Boer, D.; Brodsky, S. J.; Mulders, P.J.G.; Pisano, C.

    2011-01-01

    We show that linearly polarized gluons inside unpolarized hadrons can be directly probed in jet or heavy quark pair production in electron-hadron collisions. We discuss the simplest cos2 asymmetries and estimate their maximal value, concluding that measurements of the unknown linearly polarized

  15. Spectroscopic information from different theoretical descriptions of (un)polarized (e,e sup ' p) reactions

    CERN Document Server

    Radici, M; Dickhoff, W H

    2003-01-01

    We analyze the unpolarized and polarized electron-induced proton knockout reactions on sup 1 sup 6 O in different kinematical settings using two theoretical approaches. The first one is based on a relativistic mean-field distorted-wave description of the bound and scattering states of the proton, including a fully relativistic electromagnetic current operator. The second approach adopts the same current operator, but describes the proton properties on the basis of microscopic calculations of the self-energy in sup 1 sup 6 O below the Fermi energy and final-state damping in nuclear matter above the Fermi energy, using the same realistic short-range and tensor correlations. Good agreement with all unpolarized data is obtained at low and high Q sup 2 by using the same spectroscopic factors fixed by the low-Q sup 2 analysis. A reasonable agreement is achieved for polarization observables. (orig.)

  16. Moments of unpolarized nucleon structure functions in chirally improved lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Goeckeler, Meinulf; Maurer, Thilo; Schaefer, Andreas [University of Regensburg (Germany); Lang, Christian B.; Limmer, Markus [University of Graz (Austria)

    2008-07-01

    We present our results for the lowest moments of unpolarized nucleon structure functions at leading twist. We employ lattice quantum chromodynamics using chirally improved fermions in quenched as well as dynamical simulations.

  17. Accessing the distribution of linearly polarized gluons in unpolarized hadrons

    NARCIS (Netherlands)

    Boer, Daniël; Brodsky, Stanley J.; Mulders, Piet J.; Pisano, Cristian

    2011-01-01

    Gluons inside unpolarized hadrons can be linearly polarized provided they have a nonzero transverse momentum. The simplest and theoretically safest way to probe this distribution of linearly polarized gluons is through cos(2 phi) asymmetries in heavy quark pair or dijet production in electron-hadron

  18. 2D scattering of unpolarized beams of electrons by charged nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Senbeta, Teshome, E-mail: teshearada@yahoo.com [Department of Physics, Addis Ababa University, P.O. Box 1176, Addis Ababa (Ethiopia); Mal' nev, V.N., E-mail: vnmalnev@aau.edu.et [Department of Physics, Addis Ababa University, P.O. Box 1176, Addis Ababa (Ethiopia)

    2012-07-15

    2D spin-dependent scattering of slow unpolarized beams of electrons by charged nanomagnets is analyzed in the Born approximation. The obtained scattering lengths are larger than those from the neutral nanomagnets approximately by one order. It is shown that for particular parameters of the system it is possible to polarize completely the scattered electrons in a narrow range of scattering angles. The most suitable system for realization of these effects is 2D Si electron gas with immersed nanomagnets. - Highlights: Black-Right-Pointing-Pointer We study 2D spin dependent electron scattering by charged nanomagnets. Black-Right-Pointing-Pointer The applicability of the Born approximation to the problem is discussed. Black-Right-Pointing-Pointer Unpolarized incident beams used to obtain completely polarized scattered electrons. Black-Right-Pointing-Pointer The study shows peculiarities of 2D spin dependent scattering enhanced by Coulomb potential. Black-Right-Pointing-Pointer The result obtained can be used as one method of controlling spin currents.

  19. COSY Juelich - a cooler synchrotron for unpolarized and polarized medium-energy studies

    International Nuclear Information System (INIS)

    Seyfarth, H.

    2001-01-01

    Full text: The Forschungszentrum Juelich (Research Center Juelich) is one of the sixteen national research institutions in the 'Hermann von Helmholtz Association of German Research Centers'. It is dedicated to fundamental and applied research and development which can be summarized under five priorities: (i) structure of matter and materials research, (ii) information technology, (iii) life sciences, (iv) environment precaution research, and (v) energy technology. As one of the institutes within (i). the Institut fur Kernphysik (Institute for Nuclear Research) operates the COSY cooler synchrotron which allows to accelerate unpolarized and polarized protons and deuterons to the maximum momentum of 3450 MeV/c (2640 MeV and 2050 MeV kinetic energy for protons and deuterons, respectively). At low energy electron cooling can be used for beam preparation, whereas stochastic cooling can be applied to the accelerated beam. In the first years of operation since 1993 the experiments have been performed with the unpolarized proton beam. Since 1997 the polarized proton beam is available with increasing intensity and a typical degree of polarization of about 75 % up to the maximum beam energy. In 2000 the first unpolarized deuteron beam could be accelerated and stored at the maximum energy. Four target places exist for the internal experiments PISA. EDDA, COSY-II, and ANKE which use the circulating beam with thin solid strip or fiber targets and gas targets. The four experiments TOF, MOMO, GEM, NESSI, and JESSICA are using external beams. The programs of the experiments JESSICA (Juelich Experimental Spallation Setup in the COSY Area), NESSI (Neutron Scintillator and Silicon), and PISA (Proton Induced Spallation) aim at the measurement of data needed or the design of the target station of the planned European Spallation neutron Source (ESS). The set-up of PISA is replacing the earlier experiment COSY-13 which successfully completed its investigations on the production of

  20. QCD evolution of (un)polarized gluon TMDPDFs and the Higgs q(T)-distribution

    NARCIS (Netherlands)

    Garcia, M.; Kasemets, T.; Mulders, P.J.G.; Pisano, C.

    2015-01-01

    Abstract: We provide the proper definition of all the leading-twist (un)polarized gluon transverse momentum dependent parton distribution functions (TMDPDFs), by considering the Higgs boson transverse momentum distribution in hadron-hadron collisions and deriving the factorization theorem in terms

  1. Two-loop massive operator matrix elements for polarized and unpolarized deep-inelastic scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bierenbaum, I.; Bluemlein, J.; Klein, S.

    2007-06-15

    The O({alpha}{sup 2}{sub s}) massive operator matrix elements for unpolarized and polarized heavy flavor production at asymptotic values Q{sup 2} >> m{sup 2} are calculated in Mellin space without applying the integration-by-parts method. (orig.)

  2. Azimuthal distributions of charged hadrons, pions, and kaons produced in deep-inelastic scattering off unpolarized protons and deuterons

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Laboratory of Physics; Akopov, N. [Yerevan Physics Institute (Armenia); Akopov, Z. [DESY Hamburg (DE)] (and others)

    2012-04-15

    The azimuthal cos {phi} and cos 2{phi} modulations of the distribution of hadrons produced in unpolarized semi-inclusive deep-inelastic scattering of electrons and positrons off hydrogen and deuterium targets have been measured in the Hermes experiment. For the first time these modulations were determined in a four-dimensional kinematic space for positively and negatively charged pions and kaons separately, as well as for unidentified hadrons. These azimuthal dependences are sensitive to the transverse motion and polarization of the quarks within the nucleon via, e.g., the Cahn, Boer-Mulders and Collins effects.

  3. J/ψ production in polarized and unpolarized ep collision and Sivers and cos 2φ asymmetries

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, Asmita; Rajesh, Sangem [Indian Institute of Technology Bombay, Department of Physics, Mumbai (India)

    2017-12-15

    We calculate the Sivers and cos 2φ azimuthal asymmetries in J/ψ production in the polarized and unpolarized semi-inclusive ep collision, respectively, using the formalism based on the transverse momentum-dependent parton distributions (TMDs). The non-relativistic QCD-based color octet model is employed in calculating the J/ψ production rate. The Sivers asymmetry in this process directly probes the gluon Sivers function. The estimated Sivers asymmetry at z = 1 is negative, which is in good agreement with the COMPASS data. The effect of TMD evolution on the Sivers asymmetry is also investigated. The cos 2φ asymmetry is sizable and probes the linearly polarized gluon distribution in an unpolarized proton. (orig.)

  4. QCD evolution of (un)polarized gluon TMDPDFs and the Higgs q T -distribution

    Science.gov (United States)

    Echevarria, Miguel G.; Kasemets, Tomas; Mulders, Piet J.; Pisano, Cristian

    2015-07-01

    We provide the proper definition of all the leading-twist (un)polarized gluon transverse momentum dependent parton distribution functions (TMDPDFs), by considering the Higgs boson transverse momentum distribution in hadron-hadron collisions and deriving the factorization theorem in terms of them. We show that the evolution of all the (un)polarized gluon TMDPDFs is driven by a universal evolution kernel, which can be resummed up to next-to-next-to-leading-logarithmic accuracy. Considering the proper definition of gluon TMDPDFs, we perform an explicit next-to-leading-order calculation of the unpolarized ( f {1/ g }), linearly polarized ( h {1/⊥ g }) and helicity ( g {1/L g }) gluon TMDPDFs, and show that, as expected, they are free from rapidity divergences. As a byproduct, we obtain the Wilson coefficients of the refactorization of these TMDPDFs at large transverse momentum. In particular, the coefficient of g {1/L g }, which has never been calculated before, constitutes a new and necessary ingredient for a reliable phenomenological extraction of this quantity, for instance at RHIC or the future AFTER@LHC or Electron-Ion Collider. The coefficients of f {1/ g } and h {1/⊥ g } have never been calculated in the present formalism, although they could be obtained by carefully collecting and recasting previous results in the new TMD formalism. We apply these results to analyze the contribution of linearly polarized gluons at different scales, relevant, for instance, for the inclusive production of the Higgs boson and the C-even pseudoscalar bottomonium state η b . Applying our resummation scheme we finally provide predictions for the Higgs boson q T -distribution at the LHC.

  5. Laser resolution of unpolarized-electron scattering cross sections into spin-conserved and spin-flip components

    International Nuclear Information System (INIS)

    Ritchie, B.

    1981-01-01

    The theory is presented for one-photon free-free absorption by electrons scattering from high-Z atoms. The absorption cross section provides sufficient information to resolve the unpolarized-electron total cross section, Vertical Barf(theta)Vertical Bar 2 +Vertical Barg(theta)Vertical Bar 2 , into its individual components for spin-nonflip, Vertical Barf(theta)Vertical Bar 2 , and spin-flip, Vertical Barg(theta)Vertical Bar 2 , scattering. The observation of a spin-polarization effect for a spin-independent process (free-free absorption) is analogous to the Fano effect for bound-free absorption

  6. The cos2φ azimuthal asymmetry of unpolarized dilepton production at the Z pole

    International Nuclear Information System (INIS)

    Lu Zhun; Schmidt, Ivan

    2011-01-01

    We calculate the Boer-Mulders effect contribution to the cos2φ azimuthal asymmetry of unpolarized dilepton production near the Z-pole. Based on the tree-level expression in the transverse momentum dependent factorization framework, we show that the corresponding asymmetry near the Z-pole is negative, which is opposite to the asymmetry in the low Q 2 region, dominated by the production via a virtual photon. We calculate the asymmetry generated by the Boer-Mulders effect near the Z-pole at the Relativistic Heavy Ion Collider (RHIC), with √(s)=500 GeV. We find that the magnitude of the asymmetry is several percent, and therefore it is measurable. The experimental confirmation of this sign change of the asymmetry from the low Q 2 region to the Z-pole provides direct evidence of the chiral-odd structure of quarks inside an unpolarized nucleon.

  7. Bounds on Time Reversal Violation From Polarized Neutron Capture With Unpolarized Targets.

    Science.gov (United States)

    Davis, E D; Gould, C R; Mitchell, G E; Sharapov, E I

    2005-01-01

    We have analyzed constraints on parity-odd time-reversal noninvariant interactions derived from measurements of the energy dependence of parity-violating polarized neutron capture on unpolarized targets. As previous authors found, a perturbation in energy dependence due to a parity (P)-odd time (T)-odd interaction is present. However, the perturbation competes with T-even terms which can obscure the T-odd signature. We estimate the magnitudes of these competing terms and suggest strategies for a practicable experiment.

  8. Spin-resolved unpolarized neutron off-specular scattering for magnetic multilayer studies

    CERN Document Server

    Lauter, H J; Toperverg, B P; Romashev, L; Ustinov, V; Kravtsov, E; Vorobiev, A; Major, J; Nikonov, O A

    2002-01-01

    The capabilities of the method of using unpolarized neutron off-specular scattering for investigation of magnetic structures in exchange-coupled magnetic multilayers are thoroughly examined. It is demonstrated that strong anomalies in spin-flip selective scattering processes originating from magnetic fluctuations enables a straightforward determination of the coupling angle between the magnetization direction of successive Fe layers in Fe/Cr multilayers. A complete quantitative 2-dimensional data analysis of specular and off-specular scattering has been employed to provide detailed information on the lateral and transverse magnetization arrangement in the multilayer. (orig.)

  9. Infrared renormalons and the relations between the Gross-Llewellyn Smith and the Bjorken polarized and unpolarized sum rules

    International Nuclear Information System (INIS)

    Kataev, A.L.

    2005-01-01

    It is demonstrated that the infrared renormalon calculus indicates that the QCD theoretical expressions for the Gross-Llewellyn Smith sum rule and for the Bjorken polarized and unpolarized ones contain an identical negative twist-4 1/Q 2 correction. This observation is supported by the consideration of the results of calculations of the corresponding twist-4 matrix elements. Together with the indication of the similarity of perturbative QCD contributions to these three sum rules, this observation leads to simple new theoretical relations between the Gross-Llewellyn Smith and Bjorken polarized and unpolarized sum rules in the energy region Q 2 ≥ 1 GeV 2 . The validity of this relation is checked using concrete experimental data for the Gross-Llewellyn Smith and Bjorken polarized sum rules [ru

  10. The ratio R = dσL/dσT in heavy-quark pair leptoproduction as a probe of linearly polarized gluons in unpolarized proton

    Science.gov (United States)

    Efremov, A. V.; Ivanov, N. Ya.; Teryaev, O. V.

    2018-05-01

    We study the Callan-Gross ratio R = dσL / dσT in heavy-quark pair leptoproduction, lN →l‧ Q Q bar X, as a probe of linearly polarized gluons inside unpolarized proton, where dσT (dσL) is the differential cross section of the γ* N → Q Q bar X process initiated by a transverse (longitudinal) virtual photon. Note first that the maximal value for the quantity R allowed by the photon-gluon fusion with unpolarized gluons is large, about 2. We calculate the contribution of the transverse-momentum dependent gluonic counterpart of the Boer-Mulders function, h1 ⊥g , describing the linear polarization of gluons inside unpolarized proton. Our analysis shows that the maximum value of the ratio R depends strongly on the gluon polarization; it varies from 0 to Q2/4m2 depending on h1⊥g . We conclude that the Callan-Gross ratio in heavy-quark pair leptoproduction is predicted to be large and very sensitive to the contribution of linearly polarized gluons. For this reason, future measurements of the longitudinal and transverse components of the charm and bottom production cross sections at the proposed EIC and LHeC colliders seem to be very promising for determination of the linear polarization of gluons inside unpolarized proton.

  11. Sum rules across the unpolarized Compton processes involving generalized polarizabilities and moments of nucleon structure functions

    Science.gov (United States)

    Lensky, Vadim; Hagelstein, Franziska; Pascalutsa, Vladimir; Vanderhaeghen, Marc

    2018-04-01

    We derive two new sum rules for the unpolarized doubly virtual Compton scattering process on a nucleon, which establish novel low-Q2 relations involving the nucleon's generalized polarizabilities and moments of the nucleon's unpolarized structure functions F1(x ,Q2) and F2(x ,Q2). These relations facilitate the determination of some structure constants which can only be accessed in off-forward doubly virtual Compton scattering, not experimentally accessible at present. We perform an empirical determination for the proton and compare our results with a next-to-leading-order chiral perturbation theory prediction. We also show how these relations may be useful for a model-independent determination of the low-Q2 subtraction function in the Compton amplitude, which enters the two-photon-exchange contribution to the Lamb shift of (muonic) hydrogen. An explicit calculation of the Δ (1232 )-resonance contribution to the muonic-hydrogen 2 P -2 S Lamb shift yields -1 ±1 μ eV , confirming the previously conjectured smallness of this effect.

  12. Unpolarized and polarized parton densities in term of Fermi-Dirac distributions

    International Nuclear Information System (INIS)

    Bourrely, C.

    1996-01-01

    A description of quark parton densities of the proton in terms of Fermi-Dirac distributions parametrized with very few parameters is given. It allows a fair description of the NMC, BCDMS, SLAC and HERA data on F 2 p (x,Q 2 ) in a broad range of x and Q 2 . With some simple assumptions unpolarized and polarized quark parton distributions are related which lead to a fair description of the spin-dependent structure functions xg 1 p (x,Q 2 ) and xg 1 n (x,Q 2 ). Finally, several predictions are presented for lepton pair and gauge boson production in pp collisions at energies accessible in the future at RHIC. (author)

  13. QCD effects to Bjorken unpolarized sum rule for νN deep-inelastic scattering

    International Nuclear Information System (INIS)

    Alekhin, S I; Kataev, A L

    2003-01-01

    The possibility of the first measurement of Bjorken unpolarized sum rule for F 1 structure function of νN deep-inelastic scattering at neutrino factories is commented. The brief summary of various theoretical contributions to this sum rule is given. Using the next-to-leading set of parton distributions functions, we simulate the expected Q 2 -behaviour and emphasize that its measurement can allow us to determine the value of the QCD strong coupling constant α s with reasonable theoretical uncertainty, dominated by the ambiguity in the existing estimates of the twist-4 non-perturbative 1/Q 2 -effect

  14. Notes on T-invariance and polarization effects in the elastic scattering of a particle with spin 1/2 on the unpolarized target

    International Nuclear Information System (INIS)

    Lyuboshits, V.V.; Lyuboshits, V.L.

    1998-01-01

    In the frames of T-invariance the analysis of the general dependence of the elastic scattering effective cross section of a particle with spin 1/2 on the unpolarized target with arbitrary spin upon the initial and final polarizations of the particle has been performed. On the base of the T-symmetry of the differential scattering cross section only, without traditional consideration of the spin structure of scattering amplitudes, a simple proof of the Wolfenstein theorem is obtained (this theorem states that the degree of transverse polarization, arising in the elastic scattering of an unpolarized particle on the unpolarized target, is equal to the coefficient of left-right asymmetry in the elastic scattering of the same but transversally polarized particle on the same target). Meantime, it is ascertained that in the case of P-parity violation (conserving T-invariance) there exists no analogous universal relation between the degree of longitudinal polarization and the coefficient of P-odd spin asymmetry in the scattering of longitudinally polarized particles. It is shown, further, that under T-invariance the amplitude and cross section of 'backward' scattering of neutrons on zero-spin nuclei do not depend on spin, and the observation of such a dependence would testify unambiguously to the T-invariance violation. However, according to the fulfilled estimates, the T-noninvariant spin asymmetry in the 'backward' scattering is very small (about 10 -8 - 10 -7 )

  15. Unpolarized release of vaccinia virus and HIV antigen by colchicine treatment enhances intranasal HIV antigen expression and mucosal humoral responses.

    Directory of Open Access Journals (Sweden)

    Yan Zhang

    Full Text Available The induction of a strong mucosal immune response is essential to building successful HIV vaccines. Highly attenuated recombinant HIV vaccinia virus can be administered mucosally, but even high doses of immunization have been found unable to induce strong mucosal antibody responses. In order to solve this problem, we studied the interactions of recombinant HIV vaccinia virus Tiantan strain (rVTT-gagpol in mucosal epithelial cells (specifically Caco-2 cell layers and in BALB/c mice. We evaluated the impact of this virus on HIV antigen delivery and specific immune responses. The results demonstrated that rVTT-gagpol was able to infect Caco-2 cell layers and both the nasal and lung epithelia in BALB/c mice. The progeny viruses and expressed p24 were released mainly from apical surfaces. In BALB/c mice, the infection was limited to the respiratory system and was not observed in the blood. This showed that polarized distribution limited antigen delivery into the whole body and thus limited immune response. To see if this could be improved upon, we stimulated unpolarized budding of the virus and HIV antigens by treating both Caco-2 cells and BALB/c mice with colchicine. We found that, in BALB/c mice, the degree of infection and antigen expression in the epithelia went up. As a result, specific immune responses increased correspondingly. Together, these data suggest that polarized budding limits antigen delivery and immune responses, but unpolarized distribution can increase antigen expression and delivery and thus enhance specific immune responses. This conclusion can be used to optimize mucosal HIV vaccine strategies.

  16. Moeller scattering with unpolarized electrons for the development of a Moeller polarimeter at ELSA

    International Nuclear Information System (INIS)

    Hueffer, C.

    1992-07-01

    In future experiments with polarized electrons are planned at ELSA, so it is necessary to measure the polarisation of the extracted electron beam. One possibility is to use the method of Moeller-scattering. A suitable arrangement with two lucite Cerenkov-detectors has been investigated and Moeller-scattering with unpolarized electrons has been studied. A low noise-to-signal-ratio in the time spectra allowed to separate Moeller events from background. Therefore it was possible to observe the linear dependence of Moeller-scattering-events on the atomic number of the target foil and on the current of the extracted electron beam. With regard to planned experiments it was important to show that the separation of the Moeller-electrons from the primary beam by the use of one single dipole magnet has been succesful. (orig.) [de

  17. Two-loop massive operator matrix elements for unpolarized heavy flavor production to O({epsilon})

    Energy Technology Data Exchange (ETDEWEB)

    Bierenbaum, I.; Bluemlein, J.; Klein, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Schneider, C. [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation

    2008-02-15

    We calculate the O({alpha}{sup 2}{sub s}) massive operator matrix elements for the twist-2 operators, which contribute to the heavy flavor Wilson coefficients in unpolarized deeply inelastic scattering in the region Q{sup 2}>>m{sup 2}, up to the O({epsilon}) contributions. These terms contribute through the renormalization of the O({alpha}{sup 3}{sub s}) heavy flavor Wilson coefficients of the structure function F{sub 2}(x,Q{sup 2}). The calculation has been performed using light-cone expansion techniques without using the integration-by-parts method. We represent the individual Feynman diagrams by generalized hypergeometric structures, the {epsilon}-expansion of which leads to infinite sums depending on the Mellin variable N. These sums are finally expressed in terms of nested harmonic sums using the general summation techniques implemented in the Sigma package. (orig.)

  18. Unpolarized structure functions and the parton distributions for nucleon in an independent quark model

    International Nuclear Information System (INIS)

    Barik, N.; Mishra, R.N.

    2001-01-01

    Considering the nucleon as consisting entirely of its valence quarks confined independently in a scalar-vector harmonic potential; unpolarized structure functions F 1 (x, μ 2 ) and F 2 (x, μ 2 ) are derived in the Bjorken limit under certain simplifying assumptions; from which valence quark distribution functions u v (x, μ 2 ) and d v (x, μ 2 ) are appropriately extracted satisfying the normalization constraints. QCD-evolution of these input distributions from a model scale of μ 2 = 0.07 GeV 2 to a higher Q 2 scale of Q 0 2 = 15 GeV 2 yields xu v (x, Q 0 2 ) and xd v (x, Q 0 2 ) in good agreement with experimental data. The gluon and sea-quark distributions such as G (x, Q 0 2 ) and q s (x, Q 0 2 ) are dynamically generated with a reasonable qualitative agreement with the available data; using the leading order renormalization group equations with appropriate valence-quark distributions as the input. (author)

  19. Unpolarized neutral current e{sup {+-}}p cross section measurements at the H1 experiment, HERA

    Energy Technology Data Exchange (ETDEWEB)

    Habib, Shiraz Z.

    2009-11-15

    Measurements of the unpolarized inclusive neutral current reduced cross section in e{sup {+-}}p scattering at a center of mass energy {radical}(s) {approx_equal} 319 GeV are presented. The data was collected by the H1 detector during the HERA II running phase, after the 2000 luminosity upgrade, and corresponds to an integrated luminosity of 145 pb{sup -1} and 167 pb{sup -1} for the e{sup -}p and e{sup +}p periods respectively. The cross section measurements were made for the negative four-momentum transfer squared range 65{<=} Q{sup 2}{<=}30000 GeV{sup 2} and Bjorken-x range 0.00085{<=}x{<=}0.65. Dedicated measurements at inelasticity y=0.75 and Q{sup 2}{<=}800 GeV{sup 2} are also made. The details of the analysis are presented here. The cross section measurements presented here are found to agree with previously published data as well as predictions determined from various NLO QCD fits. Scaling violation of the F{sub 2} structure function as well differences between the e{sup -} and e{sup +} cross sections at high Q{sup 2} due to the xF{sub 3} structure function have been observed. The cross sections in the range Q{sup 2}{<=}800 GeV{sup 2} at inelasticity y=0.75 suggest non-zero values of the longitudinal structure function F{sub L}. (orig.)

  20. The Probiotic Mixture VSL#3 Alters the Morphology and Secretion Profile of Both Polarized and Unpolarized Human Macrophages in a Polarization-Dependent Manner

    Science.gov (United States)

    Isidro, Raymond A.; Bonilla, Fernando J.; Pagan, Hendrick; Cruz, Myrella L.; Lopez, Pablo; Godoy, Lenin; Hernandez, Siomara; Loucil-Alicea, Raisa Y.; Rivera-Amill, Vanessa; Yamamura, Yasuhiro; Isidro, Angel A.; Appleyard, Caroline B.

    2014-01-01

    Background Patients with Inflammatory Bowel Disease (IBD), most commonly Crohn’s disease (CD) or ulcerative colitis (UC), suffer from chronic intestinal inflammation of unknown etiology. Increased proinflammatory macrophages (M1) have been documented in tissue from patients with CD. Anti-inflammatory macrophages (M2) may play a role in UC given the preponderance of Th2 cytokines in this variant of IBD. Animal and clinical studies have shown that the probiotic VSL#3 can ameliorate signs and symptoms of IBD. Although animal data suggests a modulatory effect on macrophage phenotype, the effect of VSL#3 on human macrophages remains unknown. Objective To determine the effect of the probiotic VSL#3 on the phenotype of polarized (M1/M2) and unpolarized (MΦ) human macrophages. Methods Human monocyte-derived macrophages, generated by culturing monocytes with M-CSF, were left unpolarized or were polarized towards an M1 or an M2 phenotype by culture with LPS and IFN-γ or IL-4, respectively, and were then cultured in the presence or absence of VSL#3 for 3 days. Changes in macrophage morphology were assessed. Cytokine and chemokine levels in supernatants were determined by multiplex assay. Results VSL#3 decreased the granuloma-like aggregates of M1 macrophages, increased fibroblast-like M2 macrophages, and decreased fibroblast-like MΦ macrophages. VSL#3 increased the secretion of IL-1β, IL-6, IL-10, and G-CSF by M1, M2, and MΦ macrophages. VSL#3 exposure maintained the proinflammatory phenotype of M1 macrophages, sustaining IL-12 secretion, increasing IL-23 secretion, and decreasing MDC secretion. Both VSL#3-treated M2 and MΦ macrophages secreted higher levels of anti-inflammatory and pro-healing factors such as IL-1Ra, IL-13, EGF, FGF-2, TGF-α, and VEGF, as well as proinflammatory cytokines, including IL-12 and TNF-α. Conclusion Under our experimental conditions VSL#3 induced a mixed proinflammatory and anti-inflammatory phenotype in polarized and unpolarized

  1. Bidirectional reflectance distribution function of Spectralon white reflectance standard illuminated by incoherent unpolarized and plane-polarized light.

    Science.gov (United States)

    Bhandari, Anak; Hamre, Børge; Frette, Øvynd; Zhao, Lu; Stamnes, Jakob J; Kildemo, Morten

    2011-06-01

    A Lambert surface would appear equally bright from all observation directions regardless of the illumination direction. However, the reflection from a randomly scattering object generally has directional variation, which can be described in terms of the bidirectional reflectance distribution function (BRDF). We measured the BRDF of a Spectralon white reflectance standard for incoherent illumination at 405 and 680 nm with unpolarized and plane-polarized light from different directions of incidence. Our measurements show deviations of the BRDF for the Spectralon white reflectance standard from that of a Lambertian reflector that depend both on the angle of incidence and the polarization states of the incident light and detected light. The non-Lambertian reflection characteristics were found to increase more toward the direction of specular reflection as the angle of incidence gets larger.

  2. Lamp-lit bridges as dual light-traps for the night-swarming mayfly, Ephoron virgo: interaction of polarized and unpolarized light pollution.

    Directory of Open Access Journals (Sweden)

    Denes Szaz

    Full Text Available Ecological photopollution created by artificial night lighting can alter animal behavior and lead to population declines and biodiversity loss. Polarized light pollution is a second type of photopollution that triggers water-seeking insects to ovisposit on smooth and dark man-made objects, because they simulate the polarization signatures of natural water bodies. We document a case study of the interaction of these two forms of photopollution by conducting observations and experiments near a lamp-lit bridge over the river Danube that attracts mass swarms of the mayfly Ephoron virgo away from the river to oviposit on the asphalt road of the bridge. Millions of mayflies swarmed near bridge-lights for two weeks. We found these swarms to be composed of 99% adult females performing their upstream compensatory flight and were attracted upward toward unpolarized bridge-lamp light, and away from the horizontally polarized light trail of the river. Imaging polarimetry confirmed that the asphalt surface of the bridge was strongly and horizontally polarized, providing a supernormal ovipositional cue to Ephoron virgo, while other parts of the bridge were poor polarizers of lamplight. Collectively, we confirm that Ephoron virgo is independently attracted to both unpolarized and polarized light sources, that both types of photopollution are being produced at the bridge, and that spatial patterns of swarming and oviposition are consistent with evolved behaviors being triggered maladaptively by these two types of light pollution. We suggest solutions to bridge and lighting design that should prevent or mitigate the impacts of such scenarios in the future. The detrimental impacts of such scenarios may extend beyond Ephoron virgo.

  3. Lamp-lit bridges as dual light-traps for the night-swarming mayfly, Ephoron virgo: interaction of polarized and unpolarized light pollution.

    Science.gov (United States)

    Szaz, Denes; Horvath, Gabor; Barta, Andras; Robertson, Bruce A; Farkas, Alexandra; Egri, Adam; Tarjanyi, Nikolett; Racz, Gergely; Kriska, Gyorgy

    2015-01-01

    Ecological photopollution created by artificial night lighting can alter animal behavior and lead to population declines and biodiversity loss. Polarized light pollution is a second type of photopollution that triggers water-seeking insects to ovisposit on smooth and dark man-made objects, because they simulate the polarization signatures of natural water bodies. We document a case study of the interaction of these two forms of photopollution by conducting observations and experiments near a lamp-lit bridge over the river Danube that attracts mass swarms of the mayfly Ephoron virgo away from the river to oviposit on the asphalt road of the bridge. Millions of mayflies swarmed near bridge-lights for two weeks. We found these swarms to be composed of 99% adult females performing their upstream compensatory flight and were attracted upward toward unpolarized bridge-lamp light, and away from the horizontally polarized light trail of the river. Imaging polarimetry confirmed that the asphalt surface of the bridge was strongly and horizontally polarized, providing a supernormal ovipositional cue to Ephoron virgo, while other parts of the bridge were poor polarizers of lamplight. Collectively, we confirm that Ephoron virgo is independently attracted to both unpolarized and polarized light sources, that both types of photopollution are being produced at the bridge, and that spatial patterns of swarming and oviposition are consistent with evolved behaviors being triggered maladaptively by these two types of light pollution. We suggest solutions to bridge and lighting design that should prevent or mitigate the impacts of such scenarios in the future. The detrimental impacts of such scenarios may extend beyond Ephoron virgo.

  4. Unpolarized structure functions and the parton distributions for nucleon in an independent quark model

    Energy Technology Data Exchange (ETDEWEB)

    Barik, N [Dept. of Physics, Utkal Univ., Bhubaneswar (India); Mishra, R N [Dept. of Physics, Dhenkanal College, Dhenkanal (India)

    2001-04-01

    Considering the nucleon as consisting entirely of its valence quarks confined independently in a scalar-vector harmonic potential; unpolarized structure functions F{sub 1} (x, {mu}{sup 2}) and F{sub 2} (x, {mu}{sup 2}) are derived in the Bjorken limit under certain simplifying assumptions; from which valence quark distribution functions u{sub v} (x, {mu}{sup 2}) and d{sub v} (x, {mu}{sup 2}) are appropriately extracted satisfying the normalization constraints. QCD-evolution of these input distributions from a model scale of {mu}{sup 2} = 0.07 GeV{sup 2} to a higher Q{sup 2} scale of Q{sub 0}{sup 2} = 15 GeV{sup 2} yields xu{sub v} (x, Q{sub 0}{sup 2}) and xd{sub v} (x, Q{sub 0}{sup 2}) in good agreement with experimental data. The gluon and sea-quark distributions such as G (x, Q{sub 0}{sup 2}) and q{sub s} (x, Q{sub 0}{sup 2}) are dynamically generated with a reasonable qualitative agreement with the available data; using the leading order renormalization group equations with appropriate valence-quark distributions as the input. (author)

  5. Fusion with highly spin polarized HD and D2

    International Nuclear Information System (INIS)

    Honig, A.; Letzring, S.; Skupsky, S.

    1993-01-01

    The experimental efforts over the past 5 years have been aimed at carrying out ICF shots with spin-polarized D fuel. The authors successfully prepared polarized D in HD, and solved the problems of loading target shells with their carefully prepared isotopic mixtures, polarizing them so that the D polarization remains metastably frozen-in for about half a day, and carrying out the various cold transfer requirements at Syracuse, where the target is prepared, and at Rochester, where the cold target is inserted into the OMEGA fusion chamber. A principal concern during this past year was overcoming difficulties encountered in maintaining the integrity of the fragile cold target during the multitude of cold-transfers required for the experiment. These difficulties arose from insufficient rigidity of the cold transfer systems, which were constrained to be of small diameter by the narrow central access bore of the dilution refrigerator, and were exacerbated by the multitude of required target shell manipulations between different environments, each with different coupling geometry, including target shell permeation, polarization, storage, transport, retrieval and insertion into OMEGA. The authors did solve all of these problems, and were able to position a cold, high density but unpolarized target with required precision in OMEGA. Upon shooting the accurately positioned unpolarized high density cold target, no neutron yield was observed. Inspection inside the OMEGA tank after the shot indicated the absence of neutron yield was due to mal-timing or insufficient retraction rate of OMEGA's fast shroud mechanism, resulting in interception of at least 20 of the 24 laser beams by the faulty shroud. In spite of this, all elements of the complex experiment the authors originally undertook have been successfully demonstrated, and the cold retrieval concepts and methods they developed are being utilized on the ICF upgrades at Rochester and at Livermore

  6. Design and optimization of a volume-phase holographic grating for simultaneous use with red, green, and blue light using unpolarized light.

    Science.gov (United States)

    Mahamat, Adoum H; Narducci, Frank A; Schwiegerling, James

    2016-03-01

    Volume-phase holographic (VPH) gratings have been designed for use in many areas of science and technology, such as optical communication, optical imaging, and astronomy. In this paper, the design of a volume-phase holographic grating, simultaneously optimized to operate in the red, green, and blue wavelengths, is presented along with a study of its fabrication tolerances. The grating is optimized to produce 98% efficiency at λ=532  nm and at least 75% efficiency in the region between 400 and 700 nm, when the incident light is unpolarized. The optimization is done for recording in dichromated gelatin with a thickness of 12 μm, an average refractive index of 1.5, and a refractive index modulation of 0.022.

  7. Charge independence restrictions on some high energy two-body processes

    CERN Document Server

    Dass, G V

    1972-01-01

    Bounds due to isospin invariance have been considered for spin effects and for the unpolarized cross sections in some situations of experimental interest. Dynamical consequences like possible structure in the near- forward direction and some knowledge of the strength of the real part of the forward scattering amplitude follow in a model- independent way from these isospin bounds for the unpolarized differential cross sections for np to np scattering and K/sup +or-/n to K/sup +or-/n scattering at high energies. Useful bounds for the differential cross sections for high energy pn to pn scattering and for the high-energy reactions pi N to rho N and KN to K*(890)N (and also bounds for the full observed density matrix of the vector meson) have been illustrated. Some simple implications of the rotation of the reference axes (about the normal to the production plane) for the resonance density matrix bounds are pointed out. Some other applications are discussed. (38 refs).

  8. Total cross section of highly excited strings

    International Nuclear Information System (INIS)

    Lizzi, F.; Senda, I.

    1990-01-01

    The unpolarized total cross section for the joining of two highly excited strings is calculated. The calculation is performed by taking the average overall states in the given excitation levels of the initial strings. We find that the total cross section grows with the energy and momentum of the initial states. (author). 8 refs, 1 fig

  9. Magnetic structure of the swedenborgite CaBa (Co3Fe ) O7 derived by unpolarized neutron diffraction and spherical neutron polarimetry

    Science.gov (United States)

    Qureshi, N.; Díaz, M. T. Fernández; Chapon, L. C.; Senyshyn, A.; Schweika, W.; Valldor, M.

    2018-02-01

    We present a study that combines polarized and unpolarized neutrons to derive the magnetic structure of the swedenborgite compound CaBa (Co3Fe ) O7. Integrated intensities from a standard neutron diffraction experiment and polarization matrices from spherical neutron polarimetry have been simultaneously analyzed revealing a complex order, which differs from the usual spin configurations on a kagome lattice. We find that the magnetic structure is well described by a combination of two one-dimensional representations corresponding to the magnetic superspace symmetry P 21' , and it consists of spins rotating around an axis close to the [110] direction. Due to the propagation vector q =(1/3 00 ) , this modulation has cycloidal and helicoidal character rendering this system a potential multiferroic. The resulting spin configuration can be mapped onto the classical √{3 }×√{3 } structure of a kagome lattice, and it indicates an important interplay between the kagome and the triangular layers of the crystal structure.

  10. A feasibility study of high intensity positron sources for the S-band and TESLA linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Glantz, R.

    1997-10-01

    Future high energy linear colliders require luminosities above 10{sup 33} cm{sup -2}s{sup -1}. Therefore beam intensities have to be provided up to two orders of magnitude higher than achieved at present. It is comparably simple to reach high electron intensities. Positron intensities in this range, however, are difficult to realize with conventional positron sources. A new method of positron production was proposed in 1979 by V.E. Balakin and A.A. Mikhailichenko. The photons, necessary for pair production, are not generated by bremsstrahlung but by high energy electrons passing through an undulator. Based on this principle, a high intensity, unpolarized and polarized positron source for linear colliders was developed by K.Floettmann. In the present work, the requirements derived by K.Floettmann are used to study the feasibility of both the polarized and the unpolarized positron source. For economical reasons it is advantageous to use the beam after the interaction for positron production. In the main part of the present work a beam line is developed which guarantees a stable operation of the unpolarized wiggler-based positron source for the S-Band and TESLA linear collider. The requirements on the electron beam emittances are much higher for the polarized undulator-based source. For TESLA it is shown, that an operation of the polarized source is possible for design interactions. For a stable operation, taking into account perturbations at the interaction point, further investigations are necessary. For the SBLC, an operation of the polarized source is not possible with the present design.

  11. Parity nonconservation in polarized electron scattering at high energies

    International Nuclear Information System (INIS)

    Prescott, C.Y.

    1979-10-01

    Recent observations of parity violation in inelastic scattering of electrons at high energy is discussed with reference to the process e(polarized) + D(unpolarized) → e + X. The kinetics of this process, the idealized case of scattering from free quark targets, experimental techniques and results, and relations to atomic physics of parity violation in bismuth and thallium atoms with a model independent analysis. 17 references

  12. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  13. Positivity bounds on double parton distributions

    International Nuclear Information System (INIS)

    Diehl, Markus; Kasemets, Tomas

    2013-03-01

    Double hard scattering in proton-proton collisions is described in terms of double parton distributions. We derive bounds on these distributions that follow from their interpretation as probability densities, taking into account all possible spin correlations between two partons in an unpolarized proton. These bounds constrain the size of the polarized distributions and can for instance be used to set upper limits on the effects of spin correlations in double hard scattering. We show that the bounds are stable under leading-order DGLAP evolution to higher scales.

  14. High-energy electroweak neutrino-nucleon deeply virtual Compton scattering

    International Nuclear Information System (INIS)

    Machado, Magno V. T.

    2007-01-01

    In this work we estimate the differential and total cross sections for the high-energy deeply virtual Compton scattering in the weak sector. In the weak neutral sector one considers neutrino scattering off an unpolarized proton target through the exchange of Z 0 . We numerically compute the process Z*p→γp within the QCD color dipole formalism, which successfully describes the current high-energy electromagnetic DVCS experimental data. We also discuss possible applications for the weak charged sector and perform predictions for scattering on nuclear targets

  15. High voltage disconnect switch position monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Crampton, S W

    1983-08-01

    Unreliable position indication on high-voltage (HV) disconnect switches can result in equipment damage worth many times the cost of a disconnect switch. The benefits and limitations of a number of possible methods of reliably monitoring HV disconnect switches are assessed. Several methods of powering active devices at HV are noted. It is concluded that the most reliable way of monitoring switch position at reasonable cost would use a passive hermetically-sealed blade-position sensor located at HV, with a fibre-optic link between HV and ground. Separate sensors would be used for open and closed position indication. For maximum reliability the fibre-optic link would continue into the relay building. A passive magnetically actuated fibre-optic sensor has been built which demonstrates the feasibility of the concept. The sensor monitors blade position relative to the jaws in three dimensions with high resolution. A design for an improved passive magneto-optic sensor has significantly lower optical losses, allowing a single fibre-optic loop and 3 sensors to monitor closure of all phases of a disconnect switch. A similar loop would monitor switch opening. The improved sensor has a solid copper housing to provide greater immunity to fault currents, and to protect it from the environment and from physical damage. Two methods of providing a protected path for fibre-optics passing from HV to ground are proposed, one using a hollow porcelain switch-support insulator and the other using an additional small-diameter polymer insulator with optical fibres imbedded in its fibreglass core. A number of improvements are recommended which can be made to existing switches to increase their reliability. 16 refs., 13 figs., 1 tab.

  16. Thinking positively: The genetics of high intelligence

    Science.gov (United States)

    Shakeshaft, Nicholas G.; Trzaskowski, Maciej; McMillan, Andrew; Krapohl, Eva; Simpson, Michael A.; Reichenberg, Avi; Cederlöf, Martin; Larsson, Henrik; Lichtenstein, Paul; Plomin, Robert

    2015-01-01

    High intelligence (general cognitive ability) is fundamental to the human capital that drives societies in the information age. Understanding the origins of this intellectual capital is important for government policy, for neuroscience, and for genetics. For genetics, a key question is whether the genetic causes of high intelligence are qualitatively or quantitatively different from the normal distribution of intelligence. We report results from a sibling and twin study of high intelligence and its links with the normal distribution. We identified 360,000 sibling pairs and 9000 twin pairs from 3 million 18-year-old males with cognitive assessments administered as part of conscription to military service in Sweden between 1968 and 2010. We found that high intelligence is familial, heritable, and caused by the same genetic and environmental factors responsible for the normal distribution of intelligence. High intelligence is a good candidate for “positive genetics” — going beyond the negative effects of DNA sequence variation on disease and disorders to consider the positive end of the distribution of genetic effects. PMID:25593376

  17. Transverse momentum at work in high-energy scattering experiments

    Science.gov (United States)

    Signori, Andrea

    2017-01-01

    I will review some aspects of the definition and the phenomenology of Transverse-Momentum-Dependent distributions (TMDs) which are potentially interesting for the physics program at several current and future experimental facilities. First of all, I will review the definition of quark, gluon and Wilson loop TMDs based on gauge invariant hadronic matrix elements. Looking at the phenomenology of quarks, I will address the flavor dependence of the intrinsic transverse momentum in unpolarized TMDs, focusing on its extraction from Semi-Inclusive Deep-Inelastic Scattering. I will also present an estimate of its impact on the transverse momentum spectrum of W and Z bosons produced in unpolarized hadronic collisions and on the determination of the W boson mass. Moreover, the combined effect of the flavor dependence and the evolution of TMDs with the energy scale will be discussed for electron-positron annihilation. Concerning gluons, I will present from an effective theory point of view the TMD factorization theorem for the transverse momentum spectrum of pseudoscalar quarkonium produced in hadronic collisions. Relying on this, I will discuss the possibility of extracting precise information on (un)polarized gluon TMDs at a future Fixed Target Experiment at the LHC (AFTER@LHC).

  18. On positivity of parton distributions

    International Nuclear Information System (INIS)

    Altarelli, G.; Forte, S.; Ridolfi, G.

    1998-01-01

    We discuss the bounds on polarized parton distributions which follow from their definition in terms of cross section asymmetries. We spell out how the bounds obtained in the naive parton model can be derived within perturbative QCD at leading order when all quark and gluon distributions are defined in terms of suitable physical processes. We specify a convenient physical definition for the polarized and unpolarized gluon distributions in terms of Higgs production from gluon fusion. We show that these bounds are modified by subleading corrections, and we determine them up to NLO. We examine the ensuing phenomenological implications, in particular in view of the determination of the polarized gluon distribution. (orig.)

  19. On positivity of parton distributions

    CERN Document Server

    Altarelli, Guido; Ridolfi, G; Altarelli, Guido; Forte, Stefano; Ridolfi, Giovanni

    1998-01-01

    We discuss the bounds on polarized parton distributions which follow from their definition in terms of cross section asymmetries. We spell out how the bounds obtained in the naive parton model can be derived within perturbative QCD at leading order when all quark and gluon distributions are defined in terms of suitable physical processes. We specify a convenient physical definition for the polarized and unpolarized gluon distributions in terms of Higgs production from gluon fusion. We show that these bounds are modified by subleading corrections, and we determine them up to NLO. We examine the ensuing phenomenological implications, in particular in view of the determination of the polarized gluon distribution.

  20. Ultra-high vacuum photoelectron linear accelerator

    Science.gov (United States)

    Yu, David U.L.; Luo, Yan

    2013-07-16

    An rf linear accelerator for producing an electron beam. The outer wall of the rf cavity of said linear accelerator being perforated to allow gas inside said rf cavity to flow to a pressure chamber surrounding said rf cavity and having means of ultra high vacuum pumping of the cathode of said rf linear accelerator. Said rf linear accelerator is used to accelerate polarized or unpolarized electrons produced by a photocathode, or to accelerate thermally heated electrons produced by a thermionic cathode, or to accelerate rf heated field emission electrons produced by a field emission cathode.

  1. Deeply virtual compton scattering on the nucleon with the Clas Detector of Jefferson Lab: measurement of the polarized and unpolarized cross sections

    International Nuclear Information System (INIS)

    Jo, H.S.

    2007-03-01

    The Generalized Parton Distributions (GPDs), introduced in the 1990's, provide the most complete description of the structure (in quarks and gluons) of the nucleon. The Deeply Virtual Compton Scattering (DVCS), which corresponds to the 'hard' exclusive electroproduction of photons on the nucleon, is a key process among the reactions allowing access to the GPDs. A DVCS-dedicated experiment was carried out in 2005 with the CLAS detector of Jefferson Lab, using a polarized electron beam of 5.776 GeV and a hydrogen target. For this experiment, we built and used a dedicated electromagnetic calorimeter capable of detecting the final-state photon. The collected data allowed us to study the DVCS in the widest kinematic range ever accessed for this reaction: 1 2 2 , 0.1 B 2 . The work performed during this PhD includes simulation work done for the preparation of the experiment, timing calibration of one of the CLAS subsystems, and data analysis. The aim of the data analysis was the extraction of the unpolarized cross sections of the studied reaction and of the difference of the polarized cross sections, this latter observable being linearly proportional to the GPDs. The obtained results were compared to DVCS theoretical calculations based on one of the most up-to-date GPD parametrizations. (author)

  2. Positioning device for MRI-guided high intensity focused ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Damianou, Christakis [Frederick Institute of Technology (FIT), Limassol (Cyprus); MEDSONIC, LTD, Limassol (Cyprus); Ioannides, Kleanthis [Polikliniki Igia, Limassol (Cyprus); Milonas, Nicos [Frederick Institute of Technology (FIT), Limassol (Cyprus)

    2008-04-15

    A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. (orig.)

  3. Effect of Positive Training on Positive Psychological States (Character Strengths of Female High School Students

    Directory of Open Access Journals (Sweden)

    Ali Farnam

    2017-05-01

    Full Text Available psychological states of female students in second and third grades of high school. The research method was quasi-experimental with pre-test, post-test and follow-up. The sample consisted of forty students selected randomly in two groups (twenty students in each group. To collect data, Positive Psychological State Inventory (Rajaei, Khuy Nzhad and Nesaei was used. The experimental group received ninety minute positive training sessions (for two months and the control group did not receive treatment. The results of analysis  of covariance showed that positive training had positive effects on positive psychological states (trust in God, optimism, self-efficacy, duty, sense of control, targeted, hope, satisfaction with life, meaningful life, pleasant, sociability, self-esteem and self-worth, sense of peace, gratitude, and forgiveness among adolescents  both in the post  and follow-up tests

  4. The πNN coupling from high precision np charge exchange at 162 MeV

    International Nuclear Information System (INIS)

    Nilsson, J.; Blomgren, J.; Conde, H.; Elmgren, K.; Olsson, N.; Ericson, T.E.O.; Uppsala Univ.; Jonsson, O.; Nilsson, L.; Loiseau, B.; Ringbom, A.

    1995-02-01

    Differential cross sections for unpolarized neutrons of 162 MeV have been measured to high precision with particular attention to the absolute normalisation. These data can be extrapolated precisely and model-independently to the pion pole and give a πNN coupling constant g 2 =14.6±0.3 or f 2 =0.0808±0.0017. This is higher than recently suggested values. (author) 24 refs.; 3 figs.; 1 tab

  5. Performance of a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  6. Exploring the positional identities of high school science teachers

    Science.gov (United States)

    Blackwell, Edith Lavonne

    The identity of the teacher has been determined to influence classroom practices. Positional identity is defined as one's perception of self relative to others. This qualitative research study investigates the positional identity of five high school science teachers of different ethnicities and how their positional identities influence their classroom practices. Positional identity is thought to be determined by one's perception of how one's race, ethnicity, gender, age, religion and socioeconomic status position one relative to others. The methods of data collection included classroom observations, structured and semi-structured interviews, book club meetings, teacher journals, and researcher journals, demographic and online questionnaires. The teachers that overcame stereotypes based on race/ethnicity, gender and socioeconomic status felt empowered in their positional identities and were able to empower their students. The data also identified those teachers that struggle the most with finding their power within their positional identities were the immigrants that were not able to merge their personal identities within the pre-determined social positions they encountered in this society. The empowerment or powerlessness of the science teachers' positional identities impacted instruction and practices within the science classroom.

  7. High precision relative position sensing system for formation flying spacecraft

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop and test an optical sensing system that provides high precision relative position sensing for formation flying spacecraft.  A high precision...

  8. Overview of HERMES results

    Directory of Open Access Journals (Sweden)

    Van Hulse Charlotte

    2016-01-01

    Full Text Available The HERMES experiment has collected a wealth of deep-inelastic scattering data using the 27.6 GeV polarized lepton beam at HERA and various pure gas targets, both unpolarized and polarized. This allowed for a series of diverse and unique measurements. Among them are measurements that provide information on the threedimensional structure of the nucleon, both in momentum space and in position space. Results of measurements of exclusive ω production on an unpolarized and transversely polarized nucleon target, sensitive to the distribution in transverse-position and longitudinalmomentum space, are discussed as well as the three-dimensional extraction of azimuthal asymmetries measured in semi-inclusive deep-inelastic scattering, sensitive to twist-2 and twist-3 distributions in three-dimensional momentum space.

  9. Performance of high-resolution position-sensitive detectors developed for storage-ring decay experiments

    International Nuclear Information System (INIS)

    Yamaguchi, T.; Suzaki, F.; Izumikawa, T.; Miyazawa, S.; Morimoto, K.; Suzuki, T.; Tokanai, F.; Furuki, H.; Ichihashi, N.; Ichikawa, C.; Kitagawa, A.; Kuboki, T.; Momota, S.; Nagae, D.; Nagashima, M.; Nakamura, Y.; Nishikiori, R.; Niwa, T.; Ohtsubo, T.; Ozawa, A.

    2013-01-01

    Highlights: • Position-sensitive detectors were developed for storage-ring decay spectroscopy. • Fiber scintillation and silicon strip detectors were tested with heavy ion beams. • A new fiber scintillation detector showed an excellent position resolution. • Position and energy detection by silicon strip detectors enable full identification. -- Abstract: As next generation spectroscopic tools, heavy-ion cooler storage rings will be a unique application of highly charged RI beam experiments. Decay spectroscopy of highly charged rare isotopes provides us important information relevant to the stellar conditions, such as for the s- and r-process nucleosynthesis. In-ring decay products of highly charged RI will be momentum-analyzed and reach a position-sensitive detector set-up located outside of the storage orbit. To realize such in-ring decay experiments, we have developed and tested two types of high-resolution position-sensitive detectors: silicon strips and scintillating fibers. The beam test experiments resulted in excellent position resolutions for both detectors, which will be available for future storage-ring experiments

  10. High risk pregnancy in the workplace. Influencing positive outcomes.

    Science.gov (United States)

    Cannon, R B; Schmidt, J V; Cambardella, B; Browne, S E

    2000-09-01

    Childbearing employees are well served by the occupational health nurse who promotes optimal preconceptual and pregnancy health practices, uses community resources, and maintains current knowledge about high risk pregnancy prevention and care. These broad goals of care can lead to decreased absenteeism, healthier and happier employees, and more positive outcomes of pregnancy. For employees with high risk pregnancies, the role of the occupational health nurse includes, but is not limited to, facilitating awareness with the employer, making suggestions for adjusting working conditions, making frequent assessments of the employee's needs, and communicating with prenatal health care providers. Occupational health nurses should never underestimate their role and potential influence on the mother, and on her significant other, for a positive outcome of her pregnancy.

  11. An in vitro-identified high-affinity nucleosome-positioning signal is capable of transiently positioning a nucleosome in vivo

    Directory of Open Access Journals (Sweden)

    Gracey Lia E

    2010-07-01

    Full Text Available Abstract Background The physiological function of eukaryotic DNA occurs in the context of nucleosomal arrays that can expose or obscure defined segments of the genome. Certain DNA sequences are capable of strongly positioning a nucleosome in vitro, suggesting the possibility that favorable intrinsic signals might reproducibly structure chromatin segments. As high-throughput sequencing analyses of nucleosome coverage in vitro and in vivo have become possible, a vigorous debate has arisen over the degree to which intrinsic DNA:nucleosome affinities orchestrate the in vivo positions of nucleosomes, thereby controlling physical accessibility of specific sequences in DNA. Results We describe here the in vivo consequences of placing a synthetic high-affinity nucleosome-positioning signal, the 601 sequence, into a DNA plasmid vector in mice. Strikingly, the 601 sequence was sufficient to position nucleosomes during an early phase after introduction of the DNA into the mice (when the plasmid vector transgene was active. This positioning capability was transient, with a loss of strong positioning at a later time point when the transgenes had become silent. Conclusions These results demonstrate an ability of DNA sequences selected solely for nucleosome affinity to organize chromatin in vivo, and the ability of other mechanisms to overcome these interactions in a dynamic nuclear environment.

  12. Reference satellite selection method for GNSS high-precision relative positioning

    Directory of Open Access Journals (Sweden)

    Xiao Gao

    2017-03-01

    Full Text Available Selecting the optimal reference satellite is an important component of high-precision relative positioning because the reference satellite directly influences the strength of the normal equation. The reference satellite selection methods based on elevation and positional dilution of precision (PDOP value were compared. Results show that all the above methods cannot select the optimal reference satellite. We introduce condition number of the design matrix in the reference satellite selection method to improve structure of the normal equation, because condition number can indicate the ill condition of the normal equation. The experimental results show that the new method can improve positioning accuracy and reliability in precise relative positioning.

  13. Navigation and Positioning System Using High Altitude Platforms Systems (HAPS)

    Science.gov (United States)

    Tsujii, Toshiaki; Harigae, Masatoshi; Harada, Masashi

    Recently, some countries have begun conducting feasibility studies and R&D projects on High Altitude Platform Systems (HAPS). Japan has been investigating the use of an airship system that will function as a stratospheric platform for applications such as environmental monitoring, communications and broadcasting. If pseudolites were mounted on the airships, their GPS-like signals would be stable augmentations that would improve the accuracy, availability, and integrity of GPS-based positioning systems. Also, the sufficient number of HAPS can function as a positioning system independent of GPS. In this paper, a system design of the HAPS-based positioning system and its positioning error analyses are described.

  14. CD34-positive cells as stem cell support after high dose therapy

    International Nuclear Information System (INIS)

    Kvalheim, G.; Pharo, A.; Holte, H.

    1996-01-01

    Six patients, five with breast cancer and one with non-Hodgkin's lymphoma, were mobilized by chemotherapy and G-CSF. CD34-positive cells were isolated by means of immunomagnetic beads and Isolex 300 Cell Separator. Mean purity of isolated CD34-positive cells was 97% and mean yield was 54%. Three patients were treated with high dose therapy followed by reinfusion of CD34-positive cells as stem cell support. Recovery of neutrophils occurred at day 8, 11 and 13 and of platelets at day 9, 14 and 32. It is concluded that immunomagnetic isolated CD34-positive cells give high purity and yield. Although use of CD34-positive cells reduces the content of contaminating tumours cells in the graft, breast cancer cells were still detectable in two out of five CD34-positive cell products. 20 refs., 2 figs., 1 tab

  15. Nonimaging speckle interferometry for high-speed nanometer-scale position detection.

    Science.gov (United States)

    van Putten, E G; Lagendijk, A; Mosk, A P

    2012-03-15

    We experimentally demonstrate a nonimaging approach to displacement measurement for complex scattering materials. By spatially controlling the wavefront of the light that incidents on the material, we concentrate the scattered light in a focus on a designated position. This wavefront acts as a unique optical fingerprint that enables precise position detection of the illuminated material by simply measuring the intensity in the focus. By combining two fingerprints we demonstrate position detection along one in-plane dimension with a displacement resolution of 2.1 nm. As our approach does not require an image of the scattered field, it is possible to employ fast nonimaging detectors to enable high-speed position detection of scattering materials.

  16. Polarization effects in radiative recombination of an electron with a highly charged ion

    International Nuclear Information System (INIS)

    Klasnikov, A.E.; Shabaev, V.M.; Artemyev, A.N.; Kovtun, A.V.; Stoehlker, T.

    2005-01-01

    The radiative recombination of an unpolarized electron with a polarized highly charged H-like ion in its ground state is studied. The absolute and relative values of the electron spin-flip contribution to the cross section of the process for various scattering angles and photon polarizations are calculated. It is shown that, in addition to the forward and backward directions, there are some other scattering angles of the emitted photon, where, at a fixed linear photon polarization, the spin-flip transition gives a dominant contribution to the differential cross section

  17. A Study of the use of a Crystal as a `Quarter-Wave Plate' to Produce High Energy Circularly Polarized Photons

    CERN Multimedia

    Kononets, I

    2002-01-01

    %NA59 %title\\\\ \\\\We present a proposal to study the use of a crystal as a `quarter-wave plate' to produce high energy circularly polarized photons, starting from unpolarized electrons. The intention is to generate linearly polarized photons by letting electrons pass a crystalline target, where they interact coherently with the lattice nuclei. The photon polarization is subsequently turned into circular polarization after passing another crystal, which acts as a `quarter-wave plate'.

  18. Determination of UAV position using high accuracy navigation platform

    Directory of Open Access Journals (Sweden)

    Ireneusz Kubicki

    2016-07-01

    Full Text Available The choice of navigation system for mini UAV is very important because of its application and exploitation, particularly when the installed on it a synthetic aperture radar requires highly precise information about an object’s position. The presented exemplary solution of such a system draws attention to the possible problems associated with the use of appropriate technology, sensors, and devices or with a complete navigation system. The position and spatial orientation errors of the measurement platform influence on the obtained SAR imaging. Both, turbulences and maneuvers performed during flight cause the changes in the position of the airborne object resulting in deterioration or lack of images from SAR. Consequently, it is necessary to perform operations for reducing or eliminating the impact of the sensors’ errors on the UAV position accuracy. You need to look for compromise solutions between newer better technologies and in the field of software. Keywords: navigation systems, unmanned aerial vehicles, sensors integration

  19. Prototype of high resolution PET using resistive electrode position sensitive CdTe detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Matsuyama, Shigeo; Yamazaki, Hiromichi

    2008-01-01

    Downsizing detector elements makes it possible that spatial resolutions of positron emission tomography (PET) cameras are improved very much. From this point of view, semiconductor detectors are preferable. To obtain high resolution, the pixel type or the multi strip type of semiconductor detectors can be used. However, in this case, there is a low packing ratio problem, because a dead area between detector arrays cannot be neglected. Here, we propose the use of position sensitive semiconductor detectors with resistive electrode. The CdTe detector is promising as a detector for PET camera because of its high sensitivity. In this paper, we report development of prototype of high resolution PET using resistive electrode position sensitive CdTe detectors. We made 1-dimensional position sensitive CdTe detectors experimentally by changing the electrode thickness. We obtained 750 A as an appropriate thickness of position sensitive detectors, and evaluated the performance of the detector using a collimated 241 Am source. A good position resolution of 1.2 mm full width half maximum (FWHM) was obtained. On the basis of the fundamental development of resistive electrode position sensitive detectors, we constructed a prototype of high resolution PET which was a dual head type and was consisted of thirty-two 1-dimensional position sensitive detectors. In conclusion, we obtained high resolutions which are 0.75 mm (FWHM) in transaxial, and 1.5 mm (FWHM) in axial. (author)

  20. Polarized and unpolarized lepton pair forward-backward asymmetries in B → K{sub 0}{sup *}(1430)l{sup +}l{sup -} and B → Kl{sup +}l{sup -} decays in two-Higgs-doublet model

    Energy Technology Data Exchange (ETDEWEB)

    Falahati, F.; Abbasi, H. [Shiraz University, Physics Department and Biruni Observatory, College of Sciences, Shiraz (Iran, Islamic Republic of)

    2016-08-15

    In this paper we shall focus on the effects of concrete models such as the SM and 2HDM of type III on the polarized and unpolarized forward.backward asymmetries of B → K{sub 0}{sup *}(1430)l{sup +}l{sup -} and B → Kl{sup +}l{sup -} decays. The obtained results of these decay modes are compared to each other. Also, we obtain the minimum required number of events for detecting each asymmetry and compare it with the number of produced B anti B pairs at the LHC or supposed to be produced at the Super-LHC. At the end, we conclude that the study of these asymmetries for B → K{sub 0}{sup *}(1430)l{sup +}l{sup -} and B → Kl{sup +}l{sup -} processes are very effective tools for establishing new physics in the future B-physics experiments. (orig.)

  1. Designing compensator of dual servo system for high precision positioning

    International Nuclear Information System (INIS)

    Choi, Hyeun Seok; Song, Chi Woo; Han, Chang Soo; Choi, Tae Hoon; Lee, Nak Kyu; Na, Kyung Hwan

    2003-01-01

    The high precision positioning mechanism is used in various industrial fields. It is used in semiconductor manufacturing line, test instrument, bioengineering, and MEMS and so on. This paper presents a positioning mechanism with dual servo system. Dual servo system consists of a coarse stage and a fine motion stage. The course stage is driven by VCM and the actuator of fine stage is the PZT. The purposes of dual servo system are stability, higher bandwidth, and robustness. Lead compensator is applied to this control system, and is designed by PQ method. Designed compensator can improve property of positioning mechanism

  2. High luminosity electron-hadron collider eRHIC

    Energy Technology Data Exchange (ETDEWEB)

    Ptitsyn, V.; Aschenauer, E.; Bai, M.; Beebe-Wang, J.; Belomestnykh, S.; Ben-Zvi, I.; Blaskiewicz, M..; Calaga, R.; Chang, X.; Fedotov, A.; Gassner, D.; Hammons, L.; Hahn, H.; Hammons, L.; He, P.; Hao, Y.; Jackson, W.; Jain, A.; Johnson, E.C.; Kayran, D.; Kewisch, J.; Litvinenko, V.N.; Luo, Y.; Mahler, G.; McIntyre, G.; Meng, W.; Minty, M.; Parker, B.; Pikin, A.; Rao, T.; Roser, T.; Skaritka, J.; Sheehy, B.; Skaritka, J.; Tepikian, S.; Than, Y.; Trbojevic, D.; Tsoupas, N.; Tuozzolo, J.; Wang, G.; Webb, S.; Wu, Q.; Xu, W.; Pozdeyev, E.; Tsentalovich, E.

    2011-03-28

    We present the design of a future high-energy high-luminosity electron-hadron collider at RHIC called eRHIC. We plan on adding 20 (potentially 30) GeV energy recovery linacs to accelerate and to collide polarized and unpolarized electrons with hadrons in RHIC. The center-of-mass energy of eRHIC will range from 30 to 200 GeV. The luminosity exceeding 10{sup 34} cm{sup -2} s{sup -1} can be achieved in eRHIC using the low-beta interaction region with a 10 mrad crab crossing. We report on the progress of important eRHIC R&D such as the high-current polarized electron source, the coherent electron cooling, ERL test facility and the compact magnets for recirculation passes. A natural staging scenario of step-by-step increases of the electron beam energy by building-up of eRHIC's SRF linacs is presented.

  3. IBFA description of high-spin positive-parity states in Rh isotopes

    International Nuclear Information System (INIS)

    Bucurescu, D.; Cata, G.; Cutoiu, D.; Constantinescu, G.; Ivascu, M.; Zamfir, N.V.

    1985-01-01

    Properties of the odd-mass Rh isotopes are investigated in the framework of the interacting boson-fermion approximation (IBFA) model in which the odd proton moves in the 1gsub(9/2) and 2dsub(5/2) orbitals. Lifetimes of some high-spin positive-parity states in 99 Rh obtained by the recoil-distance method with the 88 Sr( 14 N,3n) reaction are also reported. Calculated excitation energies and electromagnetic properties of the high-spin positive-parity states are compared with experiment and an acceptable agreement is obtained. (orig.)

  4. High accuracy autonomous navigation using the global positioning system (GPS)

    Science.gov (United States)

    Truong, Son H.; Hart, Roger C.; Shoan, Wendy C.; Wood, Terri; Long, Anne C.; Oza, Dipak H.; Lee, Taesul

    1997-01-01

    The application of global positioning system (GPS) technology to the improvement of the accuracy and economy of spacecraft navigation, is reported. High-accuracy autonomous navigation algorithms are currently being qualified in conjunction with the GPS attitude determination flyer (GADFLY) experiment for the small satellite technology initiative Lewis spacecraft. Preflight performance assessments indicated that these algorithms are able to provide a real time total position accuracy of better than 10 m and a velocity accuracy of better than 0.01 m/s, with selective availability at typical levels. It is expected that the position accuracy will be increased to 2 m if corrections are provided by the GPS wide area augmentation system.

  5. Development of a high-resolution cavity-beam position monitor

    Directory of Open Access Journals (Sweden)

    Yoichi Inoue

    2008-06-01

    Full Text Available We have developed a high-resolution cavity-beam position monitor (BPM to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ∼nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5  μm.

  6. Development of a high-resolution cavity-beam position monitor

    Science.gov (United States)

    Inoue, Yoichi; Hayano, Hitoshi; Honda, Yosuke; Takatomi, Toshikazu; Tauchi, Toshiaki; Urakawa, Junji; Komamiya, Sachio; Nakamura, Tomoya; Sanuki, Tomoyuki; Kim, Eun-San; Shin, Seung-Hwan; Vogel, Vladimir

    2008-06-01

    We have developed a high-resolution cavity-beam position monitor (BPM) to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ˜nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF) beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5μm.

  7. High accuracy positioning using carrier-phases with the opensource GPSTK software

    OpenAIRE

    Salazar Hernández, Dagoberto José; Hernández Pajares, Manuel; Juan Zornoza, José Miguel; Sanz Subirana, Jaume

    2008-01-01

    The objective of this work is to show how using a proper GNSS data management strategy, combined with the flexibility provided by the open source "GPS Toolkit" (GPSTk), it is possible to easily develop both simple code-based processing strategies as well as basic high accuracy carrier-phase positioning techniques like Precise Point Positioning (PPP

  8. Employing Tropospheric Numerical Weather Prediction Model for High-Precision GNSS Positioning

    Science.gov (United States)

    Alves, Daniele; Gouveia, Tayna; Abreu, Pedro; Magário, Jackes

    2014-05-01

    In the past few years is increasing the necessity of realizing high accuracy positioning. In this sense, the spatial technologies have being widely used. The GNSS (Global Navigation Satellite System) has revolutionized the geodetic positioning activities. Among the existent methods one can emphasize the Precise Point Positioning (PPP) and network-based positioning. But, to get high accuracy employing these methods, mainly in real time, is indispensable to realize the atmospheric modeling (ionosphere and troposphere) accordingly. Related to troposphere, there are the empirical models (for example Saastamoinen and Hopfield). But when highly accuracy results (error of few centimeters) are desired, maybe these models are not appropriated to the Brazilian reality. In order to minimize this limitation arises the NWP (Numerical Weather Prediction) models. In Brazil the CPTEC/INPE (Center for Weather Prediction and Climate Studies / Brazilian Institute for Spatial Researches) provides a regional NWP model, currently used to produce Zenithal Tropospheric Delay (ZTD) predictions (http://satelite.cptec.inpe.br/zenital/). The actual version, called eta15km model, has a spatial resolution of 15 km and temporal resolution of 3 hours. In this paper the main goal is to accomplish experiments and analysis concerning the use of troposphere NWP model (eta15km model) in PPP and network-based positioning. Concerning PPP it was used data from dozens of stations over the Brazilian territory, including Amazon forest. The results obtained with NWP model were compared with Hopfield one. NWP model presented the best results in all experiments. Related to network-based positioning it was used data from GNSS/SP Network in São Paulo State, Brazil. This network presents the best configuration in the country to realize this kind of positioning. Actually the network is composed by twenty stations (http://www.fct.unesp.br/#!/pesquisa/grupos-de-estudo-e-pesquisa/gege//gnss-sp-network2789/). The

  9. Positivity-preserving space-time CE/SE scheme for high speed flows

    KAUST Repository

    Shen, Hua

    2017-03-02

    We develop a space-time conservation element and solution element (CE/SE) scheme using a simple slope limiter to preserve the positivity of the density and pressure in computations of inviscid and viscous high-speed flows. In general, the limiter works with all existing CE/SE schemes. Here, we test the limiter on a central Courant number insensitive (CNI) CE/SE scheme implemented on hybrid unstructured meshes. Numerical examples show that the proposed limiter preserves the positivity of the density and pressure without disrupting the conservation law; it also improves robustness without losing accuracy in solving high-speed flows.

  10. Positivity-preserving space-time CE/SE scheme for high speed flows

    KAUST Repository

    Shen, Hua; Parsani, Matteo

    2017-01-01

    We develop a space-time conservation element and solution element (CE/SE) scheme using a simple slope limiter to preserve the positivity of the density and pressure in computations of inviscid and viscous high-speed flows. In general, the limiter works with all existing CE/SE schemes. Here, we test the limiter on a central Courant number insensitive (CNI) CE/SE scheme implemented on hybrid unstructured meshes. Numerical examples show that the proposed limiter preserves the positivity of the density and pressure without disrupting the conservation law; it also improves robustness without losing accuracy in solving high-speed flows.

  11. High speed USB data logger for position sensitive detector data acquisition

    International Nuclear Information System (INIS)

    Poudel, S.K.; Kulkarni, V.B.; Kumar, Santosh; Chandak, R.M.; Krishna, P.S.R.; Mukhopadhyay, R.

    2010-01-01

    Ratio ADC (RDC) module used in neutron Position Sensitive Detector (PSD) data acquisition, gives digital code signifying the position of neutron event. A High Speed USB based RDC Data Logger card has been made for logging data from multiple RDCs to PC. A CPLD on the card continuously polls the RDCs for data, and fills it in the FIFO memory of a high speed USB microcontroller. A VC++ program for neutron scattering experiments reads event codes from FIFO of microcontroller and builds spectrum on PC. This program sweeps physical parameters of sample and collects PSD data for pre-determined monitor counts. (author)

  12. Study on the performance of large area MRPC with high position resolution

    Energy Technology Data Exchange (ETDEWEB)

    Yue Qian, E-mail: yueq@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China); Wu Yucheng; Li Yuanjing; Ye Jin; Cheng Jianping; Wang Yi; Li Jin [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China)

    2012-01-01

    Multi-gap resistive plate chamber (MRPC), which is mostly developed in high energy physics domain with excellent time resolution, is also highlighted in imaging applications. A set of 50 cm Multiplication-Sign 50 cm large area MRPC with high position resolution was successfully developed by our group and different experiments have been done to test its performances. Cosmic ray muons were used to do the test and proper high voltage and working gas were chosen. Data analysis indicates its good detection efficiency and good position resolution, which encourages further study of its application in RPC-PET and muon tomography.

  13. High current polarized electron source

    Science.gov (United States)

    Suleiman, R.; Adderley, P.; Grames, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.

    2018-05-01

    Jefferson Lab operates two DC high voltage GaAs photoguns with compact inverted insulators. One photogun provides the polarized electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) up to 200 µA. The other gun is used for high average current photocathode lifetime studies at a dedicated test facility up to 4 mA of polarized beam and 10 mA of un-polarized beam. GaAs-based photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. This contribution describes techniques to maintain good vacuum while delivering high beam currents, and techniques that minimize damage due to ion bombardment, the dominant mechanism that reduces photocathode yield. Advantages of higher DC voltage include reduced space-charge emittance growth and the potential for better photocathode lifetime. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

  14. Beam position monitors for the high brightness lattice

    International Nuclear Information System (INIS)

    Ring, T.

    1985-06-01

    Engineering developments associated with the high brightness lattice and the projected change in machine operating parameters will inherently affect the diagnostics systems and devices installed at present in the storage ring. This is particularly true of the beam position monitoring (BPI) system. The new sixteen unit cell lattice with its higher betatron tune values and the limited space available in the redesigned machine straights for fitting standard BPI vessels forces a fundamental re-evaluation of the beam position monitor system. The design aims for the new system are based on accepting the space limitations imposed while still providing the monitor points required to give good radial and vertical closed orbit plots. The locations of BPI's in the redesigned machine straights is illustrated. A description of the new BPI assemblies and their calibration is given. The BPI's use capacitance button type pick-ups; their response is described. (U.K.)

  15. Test of right-handed currents in baryon semileptonic decays

    International Nuclear Information System (INIS)

    Garcia, A.; Huerta, R.; Maya, M.; Perez Marcial, R.

    1985-01-01

    The effect of a right-handed boson on baryon semileptonic decay is considered. The analysis of polarized and unpolarized decays is carried out and it is shown that the best place to look for a right-handed current (RHC) signature is in polarized baryon decay. However, our results are useful for high statistics experiments. In order to see the contribution of the right-handed currents in the case of unpolarized hyperon decay, the Cabibbo theory should be assumed. (orig.)

  16. Compton imaging with a highly-segmented, position-sensitive HPGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Steinbach, T.; Hirsch, R.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Eberth, J.; Hess, H.; Lewandowski, L. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Gernhaeuser, R.; Maier, L.; Schlarb, M.; Weiler, B.; Winkel, M. [Technische Universitaet Muenchen, Physik Department, Garching (Germany)

    2017-02-15

    A Compton camera based on a highly-segmented high-purity germanium (HPGe) detector and a double-sided silicon-strip detector (DSSD) was developed, tested, and put into operation; the origin of γ radiation was determined successfully. The Compton camera is operated in two different modes. Coincidences from Compton-scattered γ-ray events between DSSD and HPGe detector allow for best angular resolution; while the high-efficiency mode takes advantage of the position sensitivity of the highly-segmented HPGe detector. In this mode the setup is sensitive to the whole 4π solid angle. The interaction-point positions in the 36-fold segmented large-volume HPGe detector are determined by pulse-shape analysis (PSA) of all HPGe detector signals. Imaging algorithms were developed for each mode and successfully implemented. The angular resolution sensitively depends on parameters such as geometry, selected multiplicity and interaction-point distances. Best results were obtained taking into account the crosstalk properties, the time alignment of the signals and the distance metric for the PSA for both operation modes. An angular resolution between 13.8 {sup circle} and 19.1 {sup circle}, depending on the minimal interaction-point distance for the high-efficiency mode at an energy of 1275 keV, was achieved. In the coincidence mode, an increased angular resolution of 4.6 {sup circle} was determined for the same γ-ray energy. (orig.)

  17. Curious Case of Positive Current Collectors: Corrosion and Passivation at High Temperature.

    Science.gov (United States)

    Sayed, Farheen N; Rodrigues, Marco-Tulio F; Kalaga, Kaushik; Gullapalli, Hemtej; Ajayan, P M

    2017-12-20

    In the evaluation of compatibility of different components of cell for high-energy and extreme-conditions applications, the highly focused are positive and negative electrodes and their interaction with electrolyte. However, for high-temperature application, the other components are also of significant influence and contribute toward the total health of battery. In present study, we have investigated the behavior of aluminum, the most common current collector for positive electrode materials for its electrochemical and temperature stability. For electrochemical stability, different electrolytes, organic and room temperature ionic liquids with varying Li salts (LiTFSI, LiFSI), are investigated. The combination of electrochemical and spectroscopic investigations reflects the varying mechanism of passivation at room and high temperature, as different compositions of decomposed complexes are found at the surface of metals.

  18. The Use of Industrial Robot Arms for High Precision Patient Positioning

    International Nuclear Information System (INIS)

    Katuin, J.E.; Schreuder, A.N.; Starks, W.M.; Doskow, J.

    2003-01-01

    The Indiana University Cyclotron Facility (IUCF) is in the process of designing and building the Midwest Proton Radiation Institute (MPRI) [1]. The design process includes the development of several patient treatment systems. This paper discusses the use of two such systems that provide for the high precision positioning of a patient. They are the Patient Positioner System and the X-ray system. The Patient Positioner System positions an immobilized patient on a support device to a treatment position based on a prescribed Treatment Plan. The X-ray system uses an industrial robot arm to position a Digital Radiography Panel to acquire an X-ray image to verify the location of the prescribed treatment volume in a patient by comparing the acquired images with reference images obtained from the patient's Treatment plan

  19. Augmentation of Quasi-Zenith Satellite Positioning System Using High Altitude Platforms Systems (HAPS)

    Science.gov (United States)

    Tsujii, Toshiaki; Harigae, Masatoshi

    Recently, some feasibility studies on a regional positioning system using the quasi-zenith satellites and the geostationary satellites have been conducted in Japan. However, the geometry of this system seems to be unsatisfactory in terms of the positioning accuracy in north-south direction. In this paper, an augmented satellite positioning system by the High Altitude Platform Systems (HAPS) is proposed since the flexibility of the HAPS location is effective to improve the geometry of satellite positioning system. The improved positioning performance of the augmented system is also demonstrated.

  20. Resolution of a High Performance Cavity Beam Position Monitor System

    International Nuclear Information System (INIS)

    Walston, S.; Chung, C.; Fitsos, P.; Gronberg, J.; Ross, M.; Khainovski, O.; Kolomensky, Y.; Loscutoff, P.; Slater, M.; Thomson, M.; Ward, D.; Boogert, S.; Vogel, V.; Meller, R.; Lyapin, A.; Malton, S.; Miller, D.; Frisch, J.; Hinton, S.; May, J.; McCormick, D.; Smith, S.; Smith, T.; White, G.; Orimoto, T.; Hayano, H.; Honda, Y.; Terunuma, N.; Urakawa, J.

    2005-01-01

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved - ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. A metrology system for the three BPMs was recently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame and has demonstrated that the three BPMs behave as a rigid-body to less than 5 nm. To date, we have demonstrated a BPM resolution of less than 20 nm over a dynamic range of +/- 20 microns

  1. Mellin moments of the O(αs3) heavy flavor contributions to unpolarized deep-inelastic scattering at Q2 >> m2 and anomalous dimensions

    International Nuclear Information System (INIS)

    Bierenbaum, I.; Bluemlein, J.; Klein, S.

    2009-04-01

    We calculate the O(α s 3 ) heavy flavor contributions to theWilson coefficients of the structure function F 2 (x,Q 2 ) and the massive operator matrix elements (OMEs) for the twist-2 operators of unpolarized deeply inelastic scattering in the region Q 2 >>m 2 . The massive Wilson coefficients are obtained as convolutions of massive OMEs and the known light flavor Wilson coefficients. We also compute the massive OMEs which are needed to evaluate heavy flavor parton distributions in the variable flavor number scheme (VFNS) to 3-loop order. All contributions to the Wilson coefficients and operator matrix elements but the genuine constant terms at O(α s 3 ) of the OMEs are derived in terms of quantities, which are known for general values in the Mellin variable N. For the operator matrix elements A (3) Qg , A (3) gq,Q and A (3) gg,Q the moments N=2 to 10, for A (3),PS Qq to N=12, and for A (3),NS qq,Q , A (3),PS qq,Q , A (3),PS gq,Q to N=14 are computed. These terms contribute to the light flavor +-combinations. For the flavor non-singlet terms, we calculate as well the odd moments N=1 to 13, corresponding to the light flavor --combinations. We also obtain the moments of the 3-loop anomalous dimensions, their color projections for the present processes respectively, in an independent calculation, which agree with the results given in the literature. (orig.)

  2. High-precision positioning of radar scatterers

    NARCIS (Netherlands)

    Dheenathayalan, P.; Small, D.; Schubert, A.; Hanssen, R.F.

    2016-01-01

    Remote sensing radar satellites cover wide areas and provide spatially dense measurements, with millions of scatterers. Knowledge of the precise position of each radar scatterer is essential to identify the corresponding object and interpret the estimated deformation. The absolute position accuracy

  3. Studies on the apple trees grafted on high-position for cold-resistance and high yield by using radioactive isotope

    International Nuclear Information System (INIS)

    Yuan Zengyu

    1985-01-01

    The effect of high-position grafting of apple trees on cold-resistance and high yield was significant. The yields of varieties 'Huantaiping' etc. grafted on high posotion after 7 years were increased by up to 100 kg per plant in comparing with that grafted on low position. The photosynthetic products synthesized by high grafting trees and 32 P absorbed by roots were studied by measuring the radioactivity of 32 P and 14 C, and by autoradiograph. The distribution of nutrient in various organs was affected by graft union, and the accumulation of photosynthetic produts in fruit bearing portions was in favour of the differentiation of flowers and the formation of fruits

  4. Combination Immunotherapy for the Treatment of High-Risk HER2-Positive Breast Cancer

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-14-1-0109 TITLE: Combination Immunotherapy for the Treatment of High-Risk HER2-Positive Breast Cancer PRINCIPAL INVESTIGATOR...Elizabeth A. Mittendorf, MD, PhD CONTRACTING ORGANIZATION: University of Texas MD Anderson Cancer Center Houston, TX 77030 REPORT DATE: October...CONTRACT NUMBER Combination Immunotherapy for the Treatment of High-Risk HER2-Positive Breast Cancer 5b. GRANT NUMBER W81XWH-14-1-0109 5c. PROGRAM

  5. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  6. A fast high-precision six-degree-of-freedom relative position sensor

    Science.gov (United States)

    Hughes, Gary B.; Macasaet, Van P.; Griswold, Janelle; Sison, Claudia A.; Lubin, Philip; Meinhold, Peter; Suen, Jonathan; Brashears, Travis; Zhang, Qicheng; Madajian, Jonathan

    2016-03-01

    Lasers are commonly used in high-precision measurement and profiling systems. Some laser measurement systems are based on interferometry principles, and others are based on active triangulation, depending on requirements of the application. This paper describes an active triangulation laser measurement system for a specific application wherein the relative position of two fixed, rigid mechanical components is to be measured dynamically with high precision in six degrees of freedom (DOF). Potential applications include optical systems with feedback to control for mechanical vibration, such as target acquisition devices with multiple focal planes. The method uses an array of several laser emitters mounted on one component. The lasers are directed at a reflective surface on the second component. The reflective surface consists of a piecewise-planar pattern such as a pyramid, or more generally a curved reflective surface such as a hyperbolic paraboloid. The reflected spots are sensed at 2-dimensional photodiode arrays on the emitter component. Changes in the relative position of the emitter component and reflective surface will shift the location of the reflected spots within photodiode arrays. Relative motion in any degree of freedom produces independent shifts in the reflected spot locations, allowing full six-DOF relative position determination between the two component positions. Response time of the sensor is limited by the read-out rate of the photodiode arrays. Algorithms are given for position determination with limits on uncertainty and sensitivity, based on laser and spot-sensor characteristics, and assuming regular surfaces. Additional uncertainty analysis is achievable for surface irregularities based on calibration data.

  7. A METHOD TO CALIBRATE THE HIGH-RESOLUTION CATANIA ASTROPHYSICAL OBSERVATORY SPECTROPOLARIMETER

    Energy Technology Data Exchange (ETDEWEB)

    Leone, F.; Gangi, M.; Giarrusso, M.; Scalia, C. [Università di Catania, Dipartimento di Fisica e Astronomia, Sezione Astrofisica, Via S. Sofia 78, I-95123 Catania (Italy); Avila, G. [ESO, Karl-Schwarzschild-Straße 2, D-85748, Garching bei München (Germany); Bellassai, G.; Bruno, P.; Catalano, S.; Benedetto, R. Di; Stefano, A. Di; Greco, V.; Martinetti, E.; Miraglia, M.; Munari, M.; Pontoni, C.; Scuderi, S.; Spanó, P. [INAF—Osservatorio Astrofisico di Catania, Via S. Sofia 78, I-95123 Catania (Italy)

    2016-05-01

    The Catania Astrophysical Observatory Spectropolarimeter (CAOS) is a white-pupil cross-dispersed échelle spectrograph with a spectral resolution of up to R  = 55,000 in the 375–1100 nm range in a single exposure, with complete coverage up to 856 nm. CAOS is linked to the 36-inch telescope, at Mount Etna Observatory, with a couple of 100 μ m optical fibers and it achieves a signal-to-noise ratio better than 60 for a V  = 10 mag star in one hour. CAOS is thermally stabilized in temperature within a 0.01 K rms, so that radial velocities are measured with a precision better than 100 m s{sup −1} from a single spectral line. Linear and circular spectropolarimetric observations are possible by means of a Savart plate working in series with a half-wave and a quarter-wave retarder plate in the 376–850 nm range. As is usual for high-resolution spectropolarimeters, CAOS is suitable to measure all Stokes parameters across spectral lines and it cannot measure the absolute degree of polarization. Observations of unpolarized standard stars show that instrumental polarization is generally zero at 550 nm and can increase up to 3% at the other wavelengths. Since polarized and unpolarized standard stars are useless, we suggest a method to calibrate a high-resolution spectropolarimeter on the basis of the polarimetric properties of spectral lines formed in the presence of a magnetic field. As applied to CAOS, observations of magnetic chemically peculiar stars of the main sequence show that the cross-talk from linear to circular polarization is smaller than 0.4% and that conversion from circular to linear is less than 2.7%. Strength and wavelength dependences of cross-talk can be entirely ascribed, via numerical simulations, to the incorrect retardance of achromatic wave plates.

  8. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  9. The role of smoking and alcohol intake in the development of high-grade squamous intraepithelial lesions among high-risk HPV-positive women

    DEFF Research Database (Denmark)

    Tolstrup, Janne; Munk, Christian; Thomsen, Birthe Lykke

    2006-01-01

    BACKGROUND: Infection with human papillomavirus is considered a necessary factor in developing high-grade squamous intraepithelial lesions of the cervix. However, most human papillomavirus positive women do not develop high-grade squamous intraepithelial lesions and other factors may be important...... for this transition. The objective of the present study was to examine if smoking and alcohol intake are associated with the risk of developing high-grade squamous intraepithelial lesions in women positive for high-risk human papillomavirus types. METHODS: We used baseline information on exposures on 548 high......-risk human papillomavirus positive women with normal cytology, comparing 94 women who developed high-grade squamous intraepithelial lesions with 454 women who remained cytologically normal. Logistic regression was applied for statistical analysis. RESULTS: Compared with never smokers, the odds ratio for high...

  10. A Lane-Level LBS System for Vehicle Network with High-Precision BDS/GPS Positioning

    Science.gov (United States)

    Guo, Chi; Guo, Wenfei; Cao, Guangyi; Dong, Hongbo

    2015-01-01

    In recent years, research on vehicle network location service has begun to focus on its intelligence and precision. The accuracy of space-time information has become a core factor for vehicle network systems in a mobile environment. However, difficulties persist in vehicle satellite positioning since deficiencies in the provision of high-quality space-time references greatly limit the development and application of vehicle networks. In this paper, we propose a high-precision-based vehicle network location service to solve this problem. The major components of this study include the following: (1) application of wide-area precise positioning technology to the vehicle network system. An adaptive correction message broadcast protocol is designed to satisfy the requirements for large-scale target precise positioning in the mobile Internet environment; (2) development of a concurrence service system with a flexible virtual expansion architecture to guarantee reliable data interaction between vehicles and the background; (3) verification of the positioning precision and service quality in the urban environment. Based on this high-precision positioning service platform, a lane-level location service is designed to solve a typical traffic safety problem. PMID:25755665

  11. High-performance HR practices, positive affect and employee outcomes

    OpenAIRE

    Mostafa, Ahmed

    2017-01-01

    Purpose – The purpose of this paper is to provide insight into the affective or emotional mechanisms that underlie the relationship between high-performance HR practices (HPHRP) and employee attitudes and behaviours. Drawing on affective events theory (AET), this paper examines a mediation model in which HPHRP influence positive affect which in turn affects job satisfaction and organizational citizenship behaviours (OCBs). Design/methodology/approach – Two-wave data was collected from a sampl...

  12. Design of a high-resolution high-stability positioning mechanism for crystal optics

    International Nuclear Information System (INIS)

    Shu, D.; Toellner, T. S.; Alp, E. E.

    1999-01-01

    The authors present a novel miniature multi-axis driving structure that will allow positioning of two crystals with better than 50-nrad angular resolution and nanometer linear driving sensitivity.The precision and stability of this structure allow the user to align or adjust an assembly of crystals to achieve the same performance as does a single channel-cut crystal, so they call it an artificial channel-cut crystal. In this paper, the particular designs and specifications, as well as the test results,for a two-axis driving structure for a high-energy-resolution artificial channel-cut crystal monochromator are presented

  13. In-beam measurement of the position resolution of a highly segmented coaxial germanium detector

    International Nuclear Information System (INIS)

    Descovich, M.; Lee, I.Y.; Fallon, P.; Cromaz, M.; Macchiavelli, A.O.; Radford, D.C.; Vetter, K.; Clark, R.M.; Deleplanque, M.A.; Stephens, F.S.; Ward, D.

    2005-01-01

    The position resolution of a highly segmented coaxial germanium detector was determined by analyzing the 2055keV γ-ray transition of Zr90 excited in a fusion-evaporation reaction. The high velocity of the Zr90 nuclei imparted large Doppler shifts. Digital analysis of the detector signals recovered the energy and position of individual γ-ray interactions. The location of the first interaction in the crystal was used to correct the Doppler energy shift. Comparison of the measured energy resolution with simulations implied a position resolution (root mean square) of 2mm in three-dimensions

  14. Dosimetry of x-rays from high-temperature plasmas

    International Nuclear Information System (INIS)

    Yamamoto, Takayoshi; Abe, Nobuyuki; Kawanishi, Masaharu

    1980-01-01

    Study on the dosimetry of ionizing radiations, especially of X-rays, emitted from high-temperature plasms has been made. As to the unpolarized Bremsstrahlung, a brief method to estimate electron temperatures with TLD is described and evaluation of average energy and current of the run-away electrons in the turbulent heating Tokamak is made by observing the half-value layer of the emitted X-rays and the total exposure per one shot of the Tokamak discharge. As to the polarized one, it is shown that the anisotropic electron temperature is related to the degree of polarization of the X-rays. Furthermore, reference is made to the possibility of developing such X-ray generators as can emit nearly monochromatic X-rays (characteristic X-rays) or polarized ones arbitrarily. (author)

  15. Intrinsic polarization of the high energy W-boson structure functions

    International Nuclear Information System (INIS)

    Ralston, J.P.; Olness, F.

    1986-01-01

    Several new issues are presented that are to be incorporated into a consistent treatment of high-energy transverse effective-W boson structure functions. The issues included the numerical importance of the proper choice of scale, and the q 2 evolution of the boson structure functions in an Altarelli-Parisi framework. We investigate a novel effect of the V-A coupling which produces a sizable intrinsic polarization of the W distributions. A preliminary estimate yields a left- to right-helicity structure function ratio W/sub L// + W/sub R/ + ≅ 1 - 21/(1 - x) + 21/(1 - x) 2 . For x ≥ 0.06, there are two lift-handed W + 's for every right-handed one in an unpolarized proton. 11 refs., 2 figs

  16. Degrees of polarization for a quantum field

    International Nuclear Information System (INIS)

    Sanchez-Soto, L L; Soederholm, J; Yustas, E C; Klimov, A B; Bjoerk, G

    2006-01-01

    Unpolarized light is invariant with respect to any SU(2) polarization transformation. Since this fully characterizes the set of density matrices representing unpolarized states, we introduce the degree of polarization of a quantum state as its distance to the set of unpolarized states. We discuss different candidates of distance, and show that they induce fundamentally different degrees of polarization

  17. Measurement of the vector np → dπ{sup 0}π{sup 0} reaction with polarized beam in the region of the d*(2380) resonance

    Energy Technology Data Exchange (ETDEWEB)

    Adlarson, P.; Calen, H.; Fransson, K.; Gullstroem, C.O.; Heijkenskjoeld, L.; Johansson, T.; Marciniewski, P.; Wolke, M.; Zlomanczuk, J. [Uppsala University, Division of Nuclear Physics, Department of Physics and Astronomy, Box 516, Uppsala (Sweden); Augustyniak, W.; Marianski, B.; Morsch, H.P.; Trzcinski, A.; Zupranski, P. [National Centre for Nuclear Research, Department of Nuclear Physics, Warsaw (Poland); Bardan, W.; Ciepal, I.; Czerwinski, E.; Jarczyk, L.; Kamys, B.; Khatri, G.; Kistryn, S.; Krzemien, W.; Magiera, A.; Moskal, P.; Rudy, Z.; Rundel, O.; Schaetti-Ozerianska, I.; Skurzok, M.; Smyrski, J.; Wronska, A.; Zielinski, M.J. [Jagiellonian University, Institute of Physics, Krakow (Poland); Bashkanov, M. [University of Edinburgh, James Clerk Maxwell Building, School of Physics and Astronomy, Edinburgh (United Kingdom); Eberhard-Karls-Universitaet Tuebingen, Physikalisches Institut, Tuebingen (Germany); Bergmann, F.S.; Demmich, K.; Huesken, N.; Khoukaz, A.; Sitterberg, K.; Taeschner, A. [Westfaelische Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Berlowski, M.; Stepaniak, J. [National Centre for Nuclear Research, High Energy Physics Department, Warsaw (Poland); Bhatt, H.; Varma, R. [Indian Institute of Technology Bombay, Department of Physics, Powai, Maharashtra (India); Bondar, A.; Kuzmin, A.; Shwartz, B. [Budker Institute of Nuclear Physics of SB RAS, Novosibirsk (Russian Federation); Novosibirsk State University, Novosibirsk (Russian Federation); Buescher, M.; Engels, R.; Goldenbaum, F.; Hejny, V.; Khan, F.A.; Lersch, D.; Lorentz, B.; Ohm, H.; Prasuhn, D.; Schadmand, S.; Sefzick, T.; Serdyuk, V.; Stassen, R.; Sterzenbach, G.; Stockhorst, H.; Zurek, M. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Clement, H. [Eberhard-Karls-Universitaet Tuebingen, Physikalisches Institut, Tuebingen (Germany); University of Tuebingen, Kepler Center for Astro- and Particle Physics, Tuebingen (Germany); Erven, A.; Erven, W.; Kemmerling, G.; Kleines, H.; Wuestner, P. [Forschungszentrum Juelich, Zentralinstitut fuer Engineering, Elektronik und Analytik, Juelich (Germany); Eyrich, W.; Zink, A. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); Fedorets, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); State Scientific Center of the Russian Federation, Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Foehl, K. [Justus-Liebig-Universitaet Giessen, II. Physikalisches Institut, Giessen (Germany); Goswami, A.; Roy, A. [Indian Institute of Technology Indore, Department of Physics, Indore, Madhya Pradesh (India); Grigoryev, K. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Petersburg Nuclear Physics Institute, High Energy Physics Division, Gatchina, Leningrad district (Russian Federation); Kirillov, D.A.; Piskunov, N.M. [Joint Institute for Nuclear Physics, Veksler and Baldin Laboratory of High Energiy Physics, Dubna, Moscow region (Russian Federation); Klos, B.; Stephan, E. [University of Silesia, August Chelkowski Institute of Physics, Katowice (Poland); Kulessa, P.; Pysz, K.; Siudak, R.; Szczurek, A. [Polish Academy of Sciences, The Henryk Niewodniczanski Institute of Nuclear Physics, Krakow (Poland); Kupsc, A.; Pszczel, D. [Uppsala University, Division of Nuclear Physics, Department of Physics and Astronomy, Box 516, Uppsala (Sweden); National Centre for Nuclear Research, High Energy Physics Department, Warsaw (Poland); Lalwani, K. [Malaviya National Institute of Technology Jaipur, JLN Marg, Department of Physics, Jaipur, Rajasthan (India); Maier, R.; Stroeher, H. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forschungszentrum Juelich, JARA-FAME, Juelich Aachen Research Alliance, Juelich (Germany); RWTH Aachen, Aachen (Germany); Perez del Rio, E. [Eberhard-Karls-Universitaet Tuebingen, Physikalisches Institut, Tuebingen (Germany); Pyszniak, A. [Uppsala University, Division of Nuclear Physics, Department of Physics and Astronomy, Box 516, Uppsala (Sweden); Jagiellonian University, Institute of Physics, Krakow (PL); Ritman, J. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (DE); Forschungszentrum Juelich, JARA-FAME, Juelich Aachen Research Alliance, Juelich (DE); RWTH Aachen, Aachen (DE); Ruhr-Universitaet Bochum, Institut fuer Experimentalphysik I, Bochum (DE); Sawant, S. [Indian Institute of Technology Bombay, Department of Physics, Powai, Maharashtra (IN); Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (DE); Skorodko, T. [Eberhard-Karls-Universitaet Tuebingen, Physikalisches Institut, Tuebingen (DE); University of Tuebingen, Kepler Center for Astro- and Particle Physics, Tuebingen (DE); Tomsk State University, Department of Physics, Tomsk (RU); Sopov, V. [State Scientific Center of the Russian Federation, Institute for Theoretical and Experimental Physics, Moscow (RU); Yamamoto, A. [High Energy Accelerator Research Organisation KEK, Tsukuba, Ibaraki (JP); Zabierowski, J. [National Centre for Nuclear Research, Department of Astrophysics, Lodz (PL); Collaboration: WASA-at-COSY Collaboration

    2016-05-15

    We report on a high-statistics measurement of the most basic double-pionic fusion reaction vector np→dπ{sup 0}π{sup 0} over the energy region of the d*(2380) resonance by use of a polarized deuteron beam and observing the double fusion reaction in the quasifree scattering mode. The measurements were performed with the WASA detector setup at COSY. The data reveal substantial analyzing powers and confirm conclusions about the d* resonance obtained from unpolarized measurements. We also confirm the previous unpolarized data obtained under complementary kinematic conditions. (orig.)

  18. The polarized neutron small-angle scattering instrument at BENSC Berlin

    International Nuclear Information System (INIS)

    Keller, T.; Krist, T.; Danzig, A.; Keiderling, U.; Mezei, F.; Wiedenmann, A.

    2000-01-01

    A polarized neutron beam has been installed at the small-angle neutron-scattering instrument V4 at BENSC Berlin. The main component of this new option is a 1.8 m long cavity transmission polarizer. The advantages of this device compared to the conventional bender polarizers are: (i) high transmission (35% of unpolarized beam at λ=6 A); (ii) the polarization is better than 93% in the wavelength band 4 A 3 O 4 particles embedded in a glass matrix) are presented and compared to a measurement with unpolarized neutrons

  19. Recent progress on HYSPEC, and its polarization analysis capabilities

    Directory of Open Access Journals (Sweden)

    Winn Barry

    2015-01-01

    Full Text Available HYSPEC is a high-intensity, direct-geometry time-of-flight spectrometer at the Spallation Neutron Source, optimized for measurement of excitations in small single-crystal specimens with optional polarization analysis capabilities. The incident neutron beam is monochromated using a Fermi chopper with short, straight blades, and is then vertically focused by Bragg scattering onto the sample position by either a highly oriented pyrolitic graphite (unpolarized or a Heusler (polarized crystal array. Neutrons are detected by a bank of 3He tubes that can be positioned over a wide range of scattering angles about the sample axis. HYSPEC entered the user program in February 2013 for unpolarized experiments, and is already experiencing a vibrant research program. Polarization analysis will be accomplished by using the Heusler crystal array to polarize the incident beam, and either a 3He spin filter or a supermirror wide-angle polarization analyser to analyse the scattered beam. The 3He spin filter employs the spin-exchange optical pumping technique. A 60∘ wide angle 3He cell that matches the detector coverage will be used for polarization analysis. The polarized gas in the post-sample wide angle cell is designed to be periodically and automatically refreshed with an adjustable pressure of polarized gas, optically pumped in a separate cell and then transferred to the wide angle cell. The supermirror analyser has 960 supermirror polarizers distributed over 60∘, and has been characterized at the Swiss Spallation Neutron Source. The current status of the instrument and the development of its polarization analysis capabilities are presented.

  20. A metrology system for a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Hinton, Shantell; Honda, Yosuke; Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2013-11-01

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved-ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  1. High sensitivity optical measurement of skin gloss

    OpenAIRE

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F.; Urbach, H. Paul; Varghese, Babu

    2017-01-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the...

  2. Three-dimensional high-precision indoor positioning strategy using Tabu search based on visible light communication

    Science.gov (United States)

    Peng, Qi; Guan, Weipeng; Wu, Yuxiang; Cai, Ye; Xie, Canyu; Wang, Pengfei

    2018-01-01

    This paper proposes a three-dimensional (3-D) high-precision indoor positioning strategy using Tabu search based on visible light communication. Tabu search is a powerful global optimization algorithm, and the 3-D indoor positioning can be transformed into an optimal solution problem. Therefore, in the 3-D indoor positioning, the optimal receiver coordinate can be obtained by the Tabu search algorithm. For all we know, this is the first time the Tabu search algorithm is applied to visible light positioning. Each light-emitting diode (LED) in the system broadcasts a unique identity (ID) and transmits the ID information. When the receiver detects optical signals with ID information from different LEDs, using the global optimization of the Tabu search algorithm, the 3-D high-precision indoor positioning can be realized when the fitness value meets certain conditions. Simulation results show that the average positioning error is 0.79 cm, and the maximum error is 5.88 cm. The extended experiment of trajectory tracking also shows that 95.05% positioning errors are below 1.428 cm. It can be concluded from the data that the 3-D indoor positioning based on the Tabu search algorithm achieves the requirements of centimeter level indoor positioning. The algorithm used in indoor positioning is very effective and practical and is superior to other existing methods for visible light indoor positioning.

  3. High-level fluorescence labeling of gram-positive pathogens.

    Directory of Open Access Journals (Sweden)

    Simone Aymanns

    Full Text Available Fluorescence labeling of bacterial pathogens has a broad range of interesting applications including the observation of living bacteria within host cells. We constructed a novel vector based on the E. coli streptococcal shuttle plasmid pAT28 that can propagate in numerous bacterial species from different genera. The plasmid harbors a promoterless copy of the green fluorescent variant gene egfp under the control of the CAMP-factor gene (cfb promoter of Streptococcus agalactiae and was designated pBSU101. Upon transfer of the plasmid into streptococci, the bacteria show a distinct and easily detectable fluorescence using a standard fluorescence microscope and quantification by FACS-analysis demonstrated values that were 10-50 times increased over the respective controls. To assess the suitability of the construct for high efficiency fluorescence labeling in different gram-positive pathogens, numerous species were transformed. We successfully labeled Streptococcus pyogenes, Streptococcus agalactiae, Streptococcus dysgalactiae subsp. equisimilis, Enterococcus faecalis, Enterococcus faecium, Streptococcus mutans, Streptococcus anginosus and Staphylococcus aureus strains utilizing the EGFP reporter plasmid pBSU101. In all of these species the presence of the cfb promoter construct resulted in high-level EGFP expression that could be further increased by growing the streptococcal and enterococcal cultures under high oxygen conditions through continuous aeration.

  4. A metrology system for a high resolution cavity beam position monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Walston, Sean, E-mail: walston2@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Boogert, Stewart [Royal Holloway, University of London, Egham (United Kingdom); Chung, Carl; Fitsos, Pete [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Frisch, Joe [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Gronberg, Jeff [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Hayano, Hitoshi [High Energy Accelerator Research Organization (KEK), Tsukuba-shi, Ibaraki-ken (Japan); Hinton, Shantell [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Honda, Yosuke [High Energy Accelerator Research Organization (KEK), Tsukuba-shi, Ibaraki-ken (Japan); Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter [University of California and Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Lyapin, Alexey; Malton, Stephen [University College London, London (United Kingdom); May, Justin; McCormick, Douglas [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Meller, Robert [Cornell University, Ithaca, NY (United States); Miller, David [University College London, London (United Kingdom); Orimoto, Toyoko [University of California and Lawrence Berkeley National Laboratory, Berkeley, CA (United States); California Institute of Technology, Pasadena, CA (United States); Ross, Marc [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Fermi National Accelerator Laboratory, Batavia, IL (United States); and others

    2013-11-11

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved–ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  5. Development of a Causal Framework linking High Perofrmance HRM Practices, Positive Psychological Capital, Creative Behaviours

    OpenAIRE

    Gupta, Vishal

    2013-01-01

    Synthesizing the ideas of high-performance Human Resource Management (HRM), positive psychological capital, and componential theory of creativity, the present study develops a multi-level causal framework linking high-performance work practices (HPWP), positive psychological capital, employee creative performance behaviors and creative performance. The paper argues that to provide a convincing explanation of the association between HRM practices and creativity, we need to improve our theoreti...

  6. A Police and Insurance Joint Management System Based on High Precision BDS/GPS Positioning

    Directory of Open Access Journals (Sweden)

    Wenwei Zuo

    2018-01-01

    Full Text Available Car ownership in China reached 194 million vehicles at the end of 2016. The traffic congestion index (TCI exceeds 2.0 during rush hour in some cities. Inefficient processing for minor traffic accidents is considered to be one of the leading causes for road traffic jams. Meanwhile, the process after an accident is quite troublesome. The main reason is that it is almost always impossible to get the complete chain of evidence when the accident happens. Accordingly, a police and insurance joint management system is developed which is based on high precision BeiDou Navigation Satellite System (BDS/Global Positioning System (GPS positioning to process traffic accidents. First of all, an intelligent vehicle rearview mirror terminal is developed. The terminal applies a commonly used consumer electronic device with single frequency navigation. Based on the high precision BDS/GPS positioning algorithm, its accuracy can reach sub-meter level in the urban areas. More specifically, a kernel driver is built to realize the high precision positioning algorithm in an Android HAL layer. Thus the third-party application developers can call the general location Application Programming Interface (API of the original standard Global Navigation Satellite System (GNSS to get high precision positioning results. Therefore, the terminal can provide lane level positioning service for car users. Next, a remote traffic accident processing platform is built to provide big data analysis and management. According to the big data analysis of information collected by BDS high precision intelligent sense service, vehicle behaviors can be obtained. The platform can also automatically match and screen the data that uploads after an accident to achieve accurate reproduction of the scene. Thus, it helps traffic police and insurance personnel to complete remote responsibility identification and survey for the accident. Thirdly, a rapid processing flow is established in this article to

  7. A Police and Insurance Joint Management System Based on High Precision BDS/GPS Positioning

    Science.gov (United States)

    Zuo, Wenwei; Guo, Chi; Liu, Jingnan; Peng, Xuan; Yang, Min

    2018-01-01

    Car ownership in China reached 194 million vehicles at the end of 2016. The traffic congestion index (TCI) exceeds 2.0 during rush hour in some cities. Inefficient processing for minor traffic accidents is considered to be one of the leading causes for road traffic jams. Meanwhile, the process after an accident is quite troublesome. The main reason is that it is almost always impossible to get the complete chain of evidence when the accident happens. Accordingly, a police and insurance joint management system is developed which is based on high precision BeiDou Navigation Satellite System (BDS)/Global Positioning System (GPS) positioning to process traffic accidents. First of all, an intelligent vehicle rearview mirror terminal is developed. The terminal applies a commonly used consumer electronic device with single frequency navigation. Based on the high precision BDS/GPS positioning algorithm, its accuracy can reach sub-meter level in the urban areas. More specifically, a kernel driver is built to realize the high precision positioning algorithm in an Android HAL layer. Thus the third-party application developers can call the general location Application Programming Interface (API) of the original standard Global Navigation Satellite System (GNSS) to get high precision positioning results. Therefore, the terminal can provide lane level positioning service for car users. Next, a remote traffic accident processing platform is built to provide big data analysis and management. According to the big data analysis of information collected by BDS high precision intelligent sense service, vehicle behaviors can be obtained. The platform can also automatically match and screen the data that uploads after an accident to achieve accurate reproduction of the scene. Thus, it helps traffic police and insurance personnel to complete remote responsibility identification and survey for the accident. Thirdly, a rapid processing flow is established in this article to meet the

  8. A Police and Insurance Joint Management System Based on High Precision BDS/GPS Positioning.

    Science.gov (United States)

    Zuo, Wenwei; Guo, Chi; Liu, Jingnan; Peng, Xuan; Yang, Min

    2018-01-10

    Car ownership in China reached 194 million vehicles at the end of 2016. The traffic congestion index (TCI) exceeds 2.0 during rush hour in some cities. Inefficient processing for minor traffic accidents is considered to be one of the leading causes for road traffic jams. Meanwhile, the process after an accident is quite troublesome. The main reason is that it is almost always impossible to get the complete chain of evidence when the accident happens. Accordingly, a police and insurance joint management system is developed which is based on high precision BeiDou Navigation Satellite System (BDS)/Global Positioning System (GPS) positioning to process traffic accidents. First of all, an intelligent vehicle rearview mirror terminal is developed. The terminal applies a commonly used consumer electronic device with single frequency navigation. Based on the high precision BDS/GPS positioning algorithm, its accuracy can reach sub-meter level in the urban areas. More specifically, a kernel driver is built to realize the high precision positioning algorithm in an Android HAL layer. Thus the third-party application developers can call the general location Application Programming Interface (API) of the original standard Global Navigation Satellite System (GNSS) to get high precision positioning results. Therefore, the terminal can provide lane level positioning service for car users. Next, a remote traffic accident processing platform is built to provide big data analysis and management. According to the big data analysis of information collected by BDS high precision intelligent sense service, vehicle behaviors can be obtained. The platform can also automatically match and screen the data that uploads after an accident to achieve accurate reproduction of the scene. Thus, it helps traffic police and insurance personnel to complete remote responsibility identification and survey for the accident. Thirdly, a rapid processing flow is established in this article to meet the

  9. A large, high performance, curved 2D position-sensitive neutron detector

    CERN Document Server

    Fried, J W; Mahler, G J; Makowiecki, D S; Mead, J A; Radeka, V; Schaknowski, N A; Smith, G C; Yu, B

    2002-01-01

    A new position-sensitive neutron detector has been designed and constructed for a protein crystallography station at LANL's pulsed neutron source. This station will be one of the most advanced instruments at a major neutron user facility for protein crystallography, fiber and membrane diffraction. The detector, based on neutron absorption in sup 3 He, has a large sensitive area of 3000 cm sup 2 , angular coverage of 120 deg. , timing resolution of 1 mu s, rate capability in excess of 10 sup 6 s sup - sup 1 , position resolution of about 1.5 mm FWHM, and efficiency >50% for neutrons of interest in the range 1-10 A. Features that are key to these remarkable specifications are the utilization of eight independently operating segments within a single gas volume, fabrication of the detector vessel and internal segments with a radius of curvature of about 70 cm, optimized position readout based on charge division and signal shaping with gated baseline restoration, and engineering design with high-strength aluminum ...

  10. Large palpable ductal carcinoma in situ is Her-2 positive with high nuclear grade.

    Science.gov (United States)

    Monabati, Ahmad; Sokouti, Ali-Reza; Noori, Sadat Noori; Safaei, Akbar; Talei, Abd-Rasul; Omidvari, Shapoor; Azarpira, Negar

    2015-01-01

    Ductal carcinoma in situ (DCIS) of the breast is a heterogeneous group with variable clinical presentation. The exact molecular mechanism is not known why some ductal carcinomas may reach to such a large size but still remains in situ. Although, molecular classification of DCIS lesions and nuclear grading are important for identification of more aggressive lesions but it is not sufficient. Our aim was to examine the expression pattern of immunohistochemical (IHC) markers of ER, PR, HER-2 in palpable DCIS lesions and compare with clinicopathological findings. Our center is referral hospital from South of Iran. Samples were obtained from fifty four patients with a diagnosis of palpable DCIS. Equivocal (2+) case in HER-2 IHC testing was more characterized by chromogenic in situ hybridization. The positive frequency of HER2, ER, and PR was 92%, 48%, and 37% respectively. Palpable DCIS lesions were significantly more HER-2 positive (92%). The DCIS cases were more likely to be of high nuclear grade (grade III) and Her-2 positive cases were more likely to be of high nuclear grade than intermediate grade. All ER negative tumors had high nuclear grade. The Her-2 positivity is suggested as the most important factor responsible for marked in situ proliferation and production of palpable mass.

  11. Predicting the Noise of High Power Fluid Targets Using Computational Fluid Dynamics

    Science.gov (United States)

    Moore, Michael; Covrig Dusa, Silviu

    The 2.5 kW liquid hydrogen (LH2) target used in the Qweak parity violation experiment is the highest power LH2 target in the world and the first to be designed with Computational Fluid Dynamics (CFD) at Jefferson Lab. The Qweak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from unpolarized liquid hydrogen at small momentum transfer (Q2 = 0 . 025 GeV2). This target satisfied the design goals of bench-marked with the Qweak target data. This work is an essential component in future designs of very high power low noise targets like MOLLER (5 kW, target noise asymmetry contribution < 25 ppm) and MESA (4.5 kW).

  12. The upgrade of the cold neutron three-axis spectrometer IN12 at the ILL

    Energy Technology Data Exchange (ETDEWEB)

    Schmalzl, K., E-mail: schmalzl@ill.fr [Jülich Centre for Neutron Science JCNS, Forschungszentrum Jülich GmbH, Outstation at ILL, BP 156, 38042 Grenoble (France); Schmidt, W. [Jülich Centre for Neutron Science JCNS, Forschungszentrum Jülich GmbH, Outstation at ILL, BP 156, 38042 Grenoble (France); Raymond, S. [Université Grenoble Alpes and CEA Grenoble, INAC MEM, 38054 Grenoble (France); Feilbach, H. [Forschungszentrum Jülich, Peter Grünberg Institut PGI 6, D-52425 Jülich (Germany); Mounier, C. [Institut Laue-Langevin, 71 Avenue des Martyrs, 38042 Grenoble Cedex 9 (France); Vettard, B. [Université Grenoble Alpes and CEA Grenoble, INAC MEM, 38054 Grenoble (France); Brückel, T. [Jülich Centre for Neutron Science JCNS and Peter Grünberg Institut PGI, JARA-FIT, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany)

    2016-05-21

    After nearly 40 years of successful operation the cold three-axis spectrometer IN12 at the Institut Laue-Langevin, Grenoble, France, has been relocated to a new position and the primary spectrometer has been upgraded. Latest modern optical components are employed. A new guide in combination with a virtual source concept and a double focusing monochromator guarantee highest flux. With its high unpolarized and polarized neutron flux IN12 allows for demanding experiments. A velocity selector in the guide ensures a clean beam and a very low background. A gain in flux of about an order of magnitude at the sample position has been achieved compared to the previous instrument and IN12's wavelength range now extends far into the warmish region.

  13. A highly accurate positioning and orientation system based on the usage of four-cluster fibre optic gyros

    International Nuclear Information System (INIS)

    Zhang, Xiaoyue; Lin, Zhili; Zhang, Chunxi

    2013-01-01

    A highly accurate positioning and orientation technique based on four-cluster fibre optic gyros (FOGs) is presented. The four-cluster FOG inertial measurement unit (IMU) comprises three low-precision FOGs, one static high-precision FOG and three accelerometers. To realize high-precision positioning and orientation, the static alignment (north-seeking) before vehicle manoeuvre was divided into a low-precision self-alignment phase and a high-precision north-seeking (online calibration) phase. The high-precision FOG measurement information was introduced to obtain high-precision azimuth alignment (north-seeking) result and achieve online calibration of the low-precision three-cluster FOG. The results of semi-physical simulation were presented to validate the availability and utility of the highly accurate positioning and orientation technique based on the four-cluster FOGs. (paper)

  14. Fincher-Burke excitations in single-Q chromium

    CERN Document Server

    Böni, P; Stadler, C; Roessli, B; Shirane, G; Werner, S A

    2002-01-01

    The low-energy excitations of incommensurate antiferromagnetic Cr have been investigated by means of high-resolution, inelastic neutron scattering with unpolarized, cold neutrons within an energy range E<9 meV. In agreement with previous measurements we observe Fincher-Burke excitations in the transverse spin density wave phase that appear between the unresolved spin-wave peaks at the incommensurate positions Q sup+-=(1+- delta,0,0). In contrast to the previous measurements, our high-resolution data shows that the Fincher-Burke modes do not follow a linear dispersion. Therefore, they have nothing in common with the acoustic phonon branch. The major part of the scattering is concentrated in the range 4 meV

  15. Probing WWγ and WWγγ couplings with high energy photon beams

    International Nuclear Information System (INIS)

    Choi, S.Y.; Schrempp, F.

    1992-01-01

    The potential of a 500 GeV 'Next Linear e + e - Collider' (NLC) for probing anomalous WWγ and WWγγ couplings in the γ(γ) mode is investigated. The γe - →W - ν and the γγ→W + W - processes are studied. Differential cross sections are given for polarized and unpolarized beams. CP violating couplings are also discussed. (K.A.) 13 refs., 6 figs

  16. High diffraction efficiency polarization gratings recorded by biphotonic holography in an azobenzene liquid crystalline polyester

    International Nuclear Information System (INIS)

    Sanchez, C.; Alcala, R.; Hvilsted, S.; Ramanujam, P. S.

    2001-01-01

    High diffraction efficiencies have been achieved with polarization gratings recorded in thin films of an azobenzene side-chain liquid crystalline polyester by means of biphotonic processes. Efficiency values up to 30% have been reached after an induction period of 300 s and subsequent evolution with the sample in darkness. These values are at least two orders of magnitude higher than those previously reported for biphotonic recording. The gratings can be erased with unpolarized blue light and partial recovery of the diffraction efficiency has been observed after the erasure process when the sample is kept in darkness. Red light illumination of the erased film increases the recovered efficiency value and the recovery rate. [copyright] 2001 American Institute of Physics

  17. High-effective position time spectrometer in actual measurements of low intensity region of electron spectra

    International Nuclear Information System (INIS)

    Babenkov, M.I.; Zhdanov, V.S.

    2002-01-01

    Magnetic position-time spectrometer was proposed in previous work, where not only electron coordinates in focal plane are measured by position sensitive detector (PSD) but places of their birth in beta source plane of a large area are fixed using another PSD, situated behind it, by quick effects, accompanying radioactive decay. PSD on the basis of macro-channel plates are used. It is succeeded in position-time spectrometer to combine beta sources of a large area with multichannel registration for a wide energy interval, that efficiency of measurements was two orders of magnitude increase d in comparison magnetic apparatus having PSD only in focal plane. Owing to two detectors' switching on coincidence the relation effect/background in increased minimum on two orders of magnitude in comparison with the same apparatus. At some complication of mathematical analysis it was obtained, that high characteristics of position-time spectrometer are kept during the use the magnetic field, providing double focusing. Owning to this focusing the gain the efficiency of measurements will make one more order of magnitude. Presented high-effective position-time spectrometer is supposed to use in the measurements of low-intensity region of electron spectra, which are important for development of fundamental physics. This is the first of all estimation of electron anti-neutrino mass by the form of beta spectrum of tritium in the region of boundary energy. Recently here there was problem of non physical negative values. This problem can be solved by using in measurement of different in principle high-effective spectrometers, which possess improved background properties. A position-time spectrometers belongs to these apparatus, which provides the best background conditions at very large effectiveness of the measurements of tritium beta spectrum in the region of boundary energy with acceptable high resolution. An important advantage of position-time spectrometer is the possibility of

  18. HIV Serosorting, Status Disclosure, and Strategic Positioning Among Highly Sexually Active Gay and Bisexual Men.

    Science.gov (United States)

    Grov, Christian; Rendina, H Jonathon; Moody, Raymond L; Ventuneac, Ana; Parsons, Jeffrey T

    2015-10-01

    Researchers have identified harm reduction strategies that gay, bisexual, and other men who have sex with men (GBMSM) use to reduce HIV transmission--including serosorting, status disclosure, and strategic positioning. We report on patterns of these behaviors among 376 highly sexually active (i.e., 9+partners, positioning; however, rates varied based on the participant's HIV status. HIV-positive and HIV-negative men both engaged in sex with men of similar status more often than they engaged in sex with men known to be a different HIV status (i.e., serosorting). However, HIV-negative men disclosed their HIV-status with about half of their partners, whereas HIV-positive participants disclosed with only about one-third. With regard to strategic positioning, HIV-positive participants were the receptive partner about half the time with their HIV-negative partners and with their HIV-positive partners. In contrast, strategic positioning was very common among HIV-negative participants-they rarely bottomed with HIV-positive partners, bottomed about one-third of the time with status-unknown partners, and 42% of the time (on average) with HIV-negative partners. Highly sexually active GBMSM are a critical population in which to both investigate HIV prevention strategies as well as develop effective intervention programs. Providers and clinicians might be well served to include a wide range of behavioral harm reduction strategies in addition to condom use and biomedical approaches to reduce onward HIV transmission.

  19. Implementation of a sliding-mode-based position sensorless drive for high-speed micro permanent-magnet synchronous motors.

    Science.gov (United States)

    Chi, Wen-Chun; Cheng, Ming-Yang

    2014-03-01

    Due to issues such as limited space, it is difficult if it is not impossible to employ a position sensor in the drive control of high-speed micro PMSMs. In order to alleviate this problem, this paper analyzes and implements a simple and robust position sensorless field-oriented control method of high-speed micro PMSMs based on the sliding-mode observer. In particular, the angular position and velocity of the rotor of the high-speed micro PMSM are estimated using the sliding-mode observer. This observer is able to accurately estimate rotor position in the low speed region and guarantee fast convergence of the observer in the high speed region. The proposed position sensorless control method is suitable for electric dental handpiece motor drives where a wide speed range operation is essential. The proposed sensorless FOC method is implemented using a cost-effective 16-bit microcontroller and tested in a prototype electric dental handpiece motor. Several experiments are performed to verify the effectiveness of the proposed method. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  20. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  1. Risk score predicts high-grade prostate cancer in DNA-methylation positive, histopathologically negative biopsies.

    Science.gov (United States)

    Van Neste, Leander; Partin, Alan W; Stewart, Grant D; Epstein, Jonathan I; Harrison, David J; Van Criekinge, Wim

    2016-09-01

    Prostate cancer (PCa) diagnosis is challenging because efforts for effective, timely treatment of men with significant cancer typically result in over-diagnosis and repeat biopsies. The presence or absence of epigenetic aberrations, more specifically DNA-methylation of GSTP1, RASSF1, and APC in histopathologically negative prostate core biopsies has resulted in an increased negative predictive value (NPV) of ∼90% and thus could lead to a reduction of unnecessary repeat biopsies. Here, it is investigated whether, in methylation-positive men, DNA-methylation intensities could help to identify those men harboring high-grade (Gleason score ≥7) PCa, resulting in an improved positive predictive value. Two cohorts, consisting of men with histopathologically negative index biopsies, followed by a positive or negative repeat biopsy, were combined. EpiScore, a methylation intensity algorithm was developed in methylation-positive men, using area under the curve of the receiver operating characteristic as metric for performance. Next, a risk score was developed combining EpiScore with traditional clinical risk factors to further improve the identification of high-grade (Gleason Score ≥7) cancer. Compared to other risk factors, detection of DNA-methylation in histopathologically negative biopsies was the most significant and important predictor of high-grade cancer, resulting in a NPV of 96%. In methylation-positive men, EpiScore was significantly higher for those with high-grade cancer detected upon repeat biopsy, compared to those with either no or low-grade cancer. The risk score resulted in further improvement of patient risk stratification and was a significantly better predictor compared to currently used metrics as PSA and the prostate cancer prevention trial (PCPT) risk calculator (RC). A decision curve analysis indicated strong clinical utility for the risk score as decision-making tool for repeat biopsy. Low DNA-methylation levels in PCa-negative biopsies led

  2. Position sensitive detection of neutrons in high radiation background field.

    Science.gov (United States)

    Vavrik, D; Jakubek, J; Pospisil, S; Vacik, J

    2014-01-01

    We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e(-) radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm(2)) spectroscopic Timepix detector adapted for neutron detection utilizing very thin (10)B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10(-4).

  3. Proposed method to produce a highly polarized e+ beam for future linear colliders

    International Nuclear Information System (INIS)

    Okugi, Toshiyuki; Chiba, Masami; Kurihara, Yoshimasa

    1996-01-01

    We propose a method to produce a spin-polarized e + beam using e + e - pair-creation by circularly polarized photons. Assuming Compton scattering of an unpolarized e - beam and circularly polarized laser light, scattered γ-rays at the high end of the energy spectrum are also circularly polarized. If those γ-rays are utilized to create e ± pairs on a thin target, the spin-polarization is preserved for e + 's at the high end of their energy spectrum. By using the injector linac of Accelerator Test Facility at KEK and a commercially available Nd:YAG pulse laser, we can expect about 10 5 polarized e + 's per second with a degree of polarization of 80% and a kinetic energy of 35-80 MeV. The apparatus for creation and measurement of polarized e + 's is being constructed. We present new idea for possible application of our method to future linear colliders by utilizing a high-power CO 2 laser. (author)

  4. Large-size high-performance transparent amorphous silicon sensors for laser beam position detection

    Energy Technology Data Exchange (ETDEWEB)

    Calderon, A. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Martinez-Rivero, C. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Matorras, F. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Rodrigo, T. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Sobron, M. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Vila, I. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Virto, A.L. [Instituto de Fisica de Cantabria. CSIC-University of Cantabria, Santander (Spain); Alberdi, J. [CIEMAT, Madrid (Spain); Arce, P. [CIEMAT, Madrid (Spain); Barcala, J.M. [CIEMAT, Madrid (Spain); Calvo, E. [CIEMAT, Madrid (Spain); Ferrando, A. [CIEMAT, Madrid (Spain)]. E-mail: antonio.ferrando@ciemat.es; Josa, M.I. [CIEMAT, Madrid (Spain); Luque, J.M. [CIEMAT, Madrid (Spain); Molinero, A. [CIEMAT, Madrid (Spain); Navarrete, J. [CIEMAT, Madrid (Spain); Oller, J.C. [CIEMAT, Madrid (Spain); Yuste, C. [CIEMAT, Madrid (Spain); Koehler, C. [Steinbeis-Transferzentrum fuer Angewandte Photovoltaik und Duennschichttechnik, Stuttgart (Germany); Lutz, B. [Steinbeis-Transferzentrum fuer Angewandte Photovoltaik und Duennschichttechnik, Stuttgart (Germany); Schubert, M.B. [Steinbeis-Transferzentrum fuer Angewandte Photovoltaik und Duennschichttechnik, Stuttgart (Germany); Werner, J.H. [Steinbeis-Transferzentrum fuer Angewandte Photovoltaik und Duennschichttechnik, Stuttgart (Germany)

    2006-09-15

    We present the measured performance of a new generation of semitransparent amorphous silicon position detectors. They have a large sensitive area (30x30mm{sup 2}) and show good properties such as a high response (about 20mA/W), an intrinsic position resolution better than 3{mu}m, a spatial-point reconstruction precision better than 10{mu}m, deflection angles smaller than 10{mu}rad and a transmission power in the visible and NIR higher than 70%.

  5. Large-size high-performance transparent amorphous silicon sensors for laser beam position detection

    International Nuclear Information System (INIS)

    Calderon, A.; Martinez-Rivero, C.; Matorras, F.; Rodrigo, T.; Sobron, M.; Vila, I.; Virto, A.L.; Alberdi, J.; Arce, P.; Barcala, J.M.; Calvo, E.; Ferrando, A.; Josa, M.I.; Luque, J.M.; Molinero, A.; Navarrete, J.; Oller, J.C.; Yuste, C.; Koehler, C.; Lutz, B.; Schubert, M.B.; Werner, J.H.

    2006-01-01

    We present the measured performance of a new generation of semitransparent amorphous silicon position detectors. They have a large sensitive area (30x30mm 2 ) and show good properties such as a high response (about 20mA/W), an intrinsic position resolution better than 3μm, a spatial-point reconstruction precision better than 10μm, deflection angles smaller than 10μrad and a transmission power in the visible and NIR higher than 70%

  6. High-precision relative position and attitude measurement for on-orbit maintenance of spacecraft

    Science.gov (United States)

    Zhu, Bing; Chen, Feng; Li, Dongdong; Wang, Ying

    2018-02-01

    In order to realize long-term on-orbit running of satellites, space stations, etc spacecrafts, in addition to the long life design of devices, The life of the spacecraft can also be extended by the on-orbit servicing and maintenance. Therefore, it is necessary to keep precise and detailed maintenance of key components. In this paper, a high-precision relative position and attitude measurement method used in the maintenance of key components is given. This method mainly considers the design of the passive cooperative marker, light-emitting device and high resolution camera in the presence of spatial stray light and noise. By using a series of algorithms, such as background elimination, feature extraction, position and attitude calculation, and so on, the high precision relative pose parameters as the input to the control system between key operation parts and maintenance equipment are obtained. The simulation results show that the algorithm is accurate and effective, satisfying the requirements of the precision operation technique.

  7. High-precision positioning system of four-quadrant detector based on the database query

    Science.gov (United States)

    Zhang, Xin; Deng, Xiao-guo; Su, Xiu-qin; Zheng, Xiao-qiang

    2015-02-01

    The fine pointing mechanism of the Acquisition, Pointing and Tracking (APT) system in free space laser communication usually use four-quadrant detector (QD) to point and track the laser beam accurately. The positioning precision of QD is one of the key factors of the pointing accuracy to APT system. A positioning system is designed based on FPGA and DSP in this paper, which can realize the sampling of AD, the positioning algorithm and the control of the fast swing mirror. We analyze the positioning error of facular center calculated by universal algorithm when the facular energy obeys Gauss distribution from the working principle of QD. A database is built by calculation and simulation with MatLab software, in which the facular center calculated by universal algorithm is corresponded with the facular center of Gaussian beam, and the database is stored in two pieces of E2PROM as the external memory of DSP. The facular center of Gaussian beam is inquiry in the database on the basis of the facular center calculated by universal algorithm in DSP. The experiment results show that the positioning accuracy of the high-precision positioning system is much better than the positioning accuracy calculated by universal algorithm.

  8. A high precision position sensor design and its signal processing algorithm for a maglev train.

    Science.gov (United States)

    Xue, Song; Long, Zhiqiang; He, Ning; Chang, Wensen

    2012-01-01

    High precision positioning technology for a kind of high speed maglev train with an electromagnetic suspension (EMS) system is studied. At first, the basic structure and functions of the position sensor are introduced and some key techniques to enhance the positioning precision are designed. Then, in order to further improve the positioning signal quality and the fault-tolerant ability of the sensor, a new kind of discrete-time tracking differentiator (TD) is proposed based on nonlinear optimal control theory. This new TD has good filtering and differentiating performances and a small calculation load. It is suitable for real-time signal processing. The stability, convergence property and frequency characteristics of the TD are studied and analyzed thoroughly. The delay constant of the TD is figured out and an effective time delay compensation algorithm is proposed. Based on the TD technology, a filtering process is introduced in to improve the positioning signal waveform when the sensor is under bad working conditions, and a two-sensor switching algorithm is designed to eliminate the positioning errors caused by the joint gaps of the long stator. The effectiveness and stability of the sensor and its signal processing algorithms are proved by the experiments on a test train during a long-term test run.

  9. A High Precision Position Sensor Design and Its Signal Processing Algorithm for a Maglev Train

    Directory of Open Access Journals (Sweden)

    Wensen Chang

    2012-04-01

    Full Text Available High precision positioning technology for a kind of high speed maglev train with an electromagnetic suspension (EMS system is studied. At first, the basic structure and functions of the position sensor are introduced and some key techniques to enhance the positioning precision are designed. Then, in order to further improve the positioning signal quality and the fault-tolerant ability of the sensor, a new kind of discrete-time tracking differentiator (TD is proposed based on nonlinear optimal control theory. This new TD has good filtering and differentiating performances and a small calculation load. It is suitable for real-time signal processing. The stability, convergence property and frequency characteristics of the TD are studied and analyzed thoroughly. The delay constant of the TD is figured out and an effective time delay compensation algorithm is proposed. Based on the TD technology, a filtering process is introduced in to improve the positioning signal waveform when the sensor is under bad working conditions, and a two-sensor switching algorithm is designed to eliminate the positioning errors caused by the joint gaps of the long stator. The effectiveness and stability of the sensor and its signal processing algorithms are proved by the experiments on a test train during a long-term test run.

  10. Simultaneous fabrication of very high aspect ratio positive nano- to milliscale structures.

    Science.gov (United States)

    Chen, Long Qing; Chan-Park, Mary B; Zhang, Qing; Chen, Peng; Li, Chang Ming; Li, Sai

    2009-05-01

    A simple and inexpensive technique for the simultaneous fabrication of positive (i.e., protruding), very high aspect (>10) ratio nanostructures together with micro- or millistructures is developed. The method involves using residual patterns of thin-film over-etching (RPTO) to produce sub-micro-/nanoscale features. The residual thin-film nanopattern is used as an etching mask for Si deep reactive ion etching. The etched Si structures are further reduced in size by Si thermal oxidation to produce amorphous SiO(2), which is subsequently etched away by HF. Two arrays of positive Si nanowalls are demonstrated with this combined RPTO-SiO(2)-HF technique. One array has a feature size of 150 nm and an aspect ratio of 26.7 and another has a feature size of 50 nm and an aspect ratio of 15. No other parallel reduction technique can achieve such a very high aspect ratio for 50-nm-wide nanowalls. As a demonstration of the technique to simultaneously achieve nano- and milliscale features, a simple Si nanofluidic master mold with positive features with dimensions varying continuously from 1 mm to 200 nm and a highest aspect ratio of 6.75 is fabricated; the narrow 200-nm section is 4.5 mm long. This Si master mold is then used as a mold for UV embossing. The embossed open channels are then closed by a cover with glue bonding. A high aspect ratio is necessary to produce unblocked closed channels after the cover bonding process of the nanofluidic chip. The combined method of RPTO, Si thermal oxidation, and HF etching can be used to make complex nanofluidic systems and nano-/micro-/millistructures for diverse applications.

  11. Subfamily logos: visualization of sequence deviations at alignment positions with high information content

    Directory of Open Access Journals (Sweden)

    Beitz Eric

    2006-06-01

    Full Text Available Abstract Background Recognition of relevant sequence deviations can be valuable for elucidating functional differences between protein subfamilies. Interesting residues at highly conserved positions can then be mutated and experimentally analyzed. However, identification of such sites is tedious because automated approaches are scarce. Results Subfamily logos visualize subfamily-specific sequence deviations. The display is similar to classical sequence logos but extends into the negative range. Positive, upright characters correspond to residues which are characteristic for the subfamily, negative, upside-down characters to residues typical for the remaining sequences. The symbol height is adjusted to the information content of the alignment position. Residues which are conserved throughout do not appear. Conclusion Subfamily logos provide an intuitive display of relevant sequence deviations. The method has proven to be valid using a set of 135 aligned aquaporin sequences in which established subfamily-specific positions were readily identified by the algorithm.

  12. Automated novel high-accuracy miniaturized positioning system for use in analytical instrumentation

    Science.gov (United States)

    Siomos, Konstadinos; Kaliakatsos, John; Apostolakis, Manolis; Lianakis, John; Duenow, Peter

    1996-01-01

    The development of three-dimensional automotive devices (micro-robots) for applications in analytical instrumentation, clinical chemical diagnostics and advanced laser optics, depends strongly on the ability of such a device: firstly to be positioned with high accuracy, reliability, and automatically, by means of user friendly interface techniques; secondly to be compact; and thirdly to operate under vacuum conditions, free of most of the problems connected with conventional micropositioners using stepping-motor gear techniques. The objective of this paper is to develop and construct a mechanically compact computer-based micropositioning system for coordinated motion in the X-Y-Z directions with: (1) a positioning accuracy of less than 1 micrometer, (the accuracy of the end-position of the system is controlled by a hard/software assembly using a self-constructed optical encoder); (2) a heat-free propulsion mechanism for vacuum operation; and (3) synchronized X-Y motion.

  13. Integrated hybrid vibration isolator with feedforward compensation for fast high-precision positioning X/Y tables

    International Nuclear Information System (INIS)

    Yan, T H; Li, Q; Xu, C; Pu, H Y; Chen, X D

    2010-01-01

    The design, realization and control technologies of a high-performance hybrid microvibration isolator for ultra-high-precision high-speed moving X/Y tables are presented in this paper—the novel isolator with integrated passive–active high level of damping. The passive damping was implemented using air-springs in both vertical and horizontal directions, with parallel linear motors in two directions to realize the active damping and the positioning functions. It is an actual hybrid isolation system because its air-spring can also be controlled through the pneumatic loop. The isolation servo system also has fast positioning capability via the feedforward compensation for the moving tables. Compared with the conventional filtered reference type control algorithms that rely on the assumption for the adaptive filter and the controlled system, in which the disturbance is estimated from the residual signal, the feedforward compensation here shows high effectiveness of vibration isolation and high-precision positioning performance for its platform. The performance of feedforward compensation has been enhanced via an efficient state estimation adaptive algorithm, the fast Kalman filter. Finally, experimental demonstration has been shown for the prototype system and the results have verified the effectiveness of the proposed isolator system design and the adaptive control algorithm for substantially enhanced damping of the platform system with the moving X/Y tables

  14. Sleep position and the ocular surface in a high airflow environment

    Directory of Open Access Journals (Sweden)

    Vinod Gauba, FRCOphth

    2014-01-01

    Full Text Available Purpose: To study the relationship between sleep position and ocular surface symptoms and signs in an high air flow environment. Methods: Prospective observational study of new patients attending the dry eye clinic was performed. Patients with pre-existing ocular history, relevant systemic history (e.g. Sjogren’s syndrome or who were using topical or systemic therapy for dry eye were not included. Data were collected from the patient to document their dry eye symptoms; preferred dependent sleeping side and their bedroom airflow. All patients were examined by a clinician blind to the patient’s responses where Schirmer’s test and slit lamp examination were performed looking for the presence of lagophthalmos and corneal epitheliopathy. Results: 48 patients enrolled into the study of which 23 were males and 25 were females with a normal and comparable age distribution. The study found a strong association between patients’ preferred sleeping side and the incidence of corneal epitheliopathy in the contralateral eye particularly in patients with evidence of lagophthalmos. Dry eye symptoms were found to be worse and tear production lower on the contralateral side to the preferred sleeping side particularly in patients who sleep in a high airflow environment. Conclusion: In patients sleeping in a high airflow environment with nocturnal lagophthalmos, this study observed an association between preferred dependent sleep position and increased dry eye symptoms, lower Schirmer’s scores and increased corneal epitheliopathy in the contralateral eye. Keywords: Sleep, Dry eyes, Lagophthalmos, Epiphora

  15. Position sensitive detection coupled to high-resolution time-of-flight mass spectrometry: Imaging for molecular beam deflection experiments

    International Nuclear Information System (INIS)

    Abd El Rahim, M.; Antoine, R.; Arnaud, L.; Barbaire, M.; Broyer, M.; Clavier, Ch.; Compagnon, I.; Dugourd, Ph.; Maurelli, J.; Rayane, D.

    2004-01-01

    We have developed and tested a high-resolution time-of-flight mass spectrometer coupled to a position sensitive detector for molecular beam deflection experiments. The major achievement of this new spectrometer is to provide a three-dimensional imaging (X and Y positions and time-of-flight) of the ion packet on the detector, with a high acquisition rate and a high resolution on both the mass and the position. The calibration of the experimental setup and its application to molecular beam deflection experiments are discussed

  16. Comparison between conventional protective mechanical ventilation and high-frequency oscillatory ventilation associated with the prone position.

    Science.gov (United States)

    Fioretto, José Roberto; Klefens, Susiane Oliveira; Pires, Rafaelle Fernandes; Kurokawa, Cilmery Suemi; Carpi, Mario Ferreira; Bonatto, Rossano César; Moraes, Marcos Aurélio; Ronchi, Carlos Fernando

    2017-01-01

    To compare the effects of high-frequency oscillatory ventilation and conventional protective mechanical ventilation associated with the prone position on oxygenation, histology and pulmonary oxidative damage in an experimental model of acute lung injury. Forty-five rabbits with tracheostomy and vascular access were underwent mechanical ventilation. Acute lung injury was induced by tracheal infusion of warm saline. Three experimental groups were formed: healthy animals + conventional protective mechanical ventilation, supine position (Control Group; n = 15); animals with acute lung injury + conventional protective mechanical ventilation, prone position (CMVG; n = 15); and animals with acute lung injury + high-frequency oscillatory ventilation, prone position (HFOG; n = 15). Ten minutes after the beginning of the specific ventilation of each group, arterial gasometry was collected, with this timepoint being called time zero, after which the animal was placed in prone position and remained in this position for 4 hours. Oxidative stress was evaluated by the total antioxidant performance assay. Pulmonary tissue injury was determined by histopathological score. The level of significance was 5%. Both groups with acute lung injury showed worsening of oxygenation after induction of injury compared with the Control Group. After 4 hours, there was a significant improvement in oxygenation in the HFOG group compared with CMVG. Analysis of total antioxidant performance in plasma showed greater protection in HFOG. HFOG had a lower histopathological lesion score in lung tissue than CMVG. High-frequency oscillatory ventilation, associated with prone position, improves oxygenation and attenuates oxidative damage and histopathological lung injury compared with conventional protective mechanical ventilation.

  17. A synbio approach for selection of highly expressed gene variants in Gram-positive bacteria

    DEFF Research Database (Denmark)

    Ferro, Roberto; Rennig, Maja; Hernández Rollán, Cristina

    2018-01-01

    with a long history in food fermentation. We have developed a synbio approach for increasing gene expression in two Gram-positive bacteria. First of all, the gene of interest was coupled to an antibiotic resistance gene to create a growth-based selection system. We then randomised the translation initiation...... region (TIR) preceding the gene of interest and selected clones that produced high protein titres, as judged by their ability to survive on high concentrations of antibiotic. Using this approach, we were able to significantly increase production of two industrially relevant proteins; sialidase in B....... subtilis and tyrosine ammonia lyase in L. lactis. Gram-positive bacteria are widely used to produce industrial enzymes. High titres are necessary to make the production economically feasible. The synbio approach presented here is a simple and inexpensive way to increase protein titres, which can be carried...

  18. Experiment study on four button electrode used to monitor position of high current electron-beam

    International Nuclear Information System (INIS)

    Xu Tiezheng; Wang Huacen; Xie Yutong; Zhang Wenwei

    2004-01-01

    The button electrode is one that widely used in high energy accelerators, such as storage ring, and the button electrode has many merit like high accuracy, high resolution, resisting magnetic field, simple machinery, without magnetic core and low cost, etc. It's helpful that the button electrode is used as the beam position monitor in the linear induction accelerator. The experimental facilities have been designed and set up and it can simulate the beam of linear induction accelerator. The button electrode beam position monitor experiment have been done on the experimental facilities. The result of the experiment prove that the button electrode has an accuracy of 0.5 mm, and can reflect the wave of electron-beam accurately

  19. Cervical cancer screening by high risk HPV testing in routine practice: results at one year recall of high risk HPV-positive and cytology-negative women.

    Science.gov (United States)

    Del Mistro, Annarosa; Frayle, Helena; Ferro, Antonio; Callegaro, Susanna; Del Sole, Annamaria; Stomeo, Anna; Cirillo, Emanuela; Fedato, Chiara; Pagni, Silvana; Barzon, Luisa; Zorzi, Manuel

    2014-03-01

    Cervical cancer screening by human papillomavirus (HPV) testing requires the use of additional triage and follow-up analyses. We evaluated women's compliance with and the performance of this strategy in a routine setting. Five cervical service screening programmes in North-East Italy. Eligible women aged 25-64 invited for a new screening episode underwent HPV testing for high risk types (hrHPV by Hybrid Capture 2) and cytology triage. Women with positive HPV and cytology results were referred for colposcopy; women with positive HPV but negative cytology results were referred to 1-year repeat hrHPV testing. Of 46,694 women screened by HPV testing up to December 2011, 3,211 (6.9%) tested hrHPV positive; 45% of these had a positive triage cytology. Those with negative cytology were invited for 1-yr repeat testing. Compliance with invitation was 61.6% at baseline and 85.3% at 1-yr repeat. Rate of persistent hrHPV positivity was 58% (830/1,435). Colposcopy performed in women with a positive hrHPV test at 1-yr repeat accounted for 36% of all colposcopies performed within the screening programmes. Cumulatively, a histological high-grade lesion was detected in 276 women (5.9‰ detection rate), 234 at baseline (85%), and 42 (15%) at 1-yr repeat. Compliance with hrHPV-based screening programmes was high both at baseline and at 1-yr repeat. Compared with the randomized trials, a higher proportion of triage cytology was read as positive, and only a small number of high-grade lesions were detected among the group of hrHPV positive cytology negative women who repeated testing 1-yr after baseline.

  20. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.

    Science.gov (United States)

    Teeter, Matthew G; Goyal, Prateek; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-01-01

    The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. Anteversion significantly increased (P cup orientation and wear rate in either position. Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Polarization of protons produced in diffractive disintegration of deuterons by high-energy pions

    International Nuclear Information System (INIS)

    Gakh, G.Yi.; Rekalo, M.P.

    1996-01-01

    For the process of diffractive disintegration of unpolarized deuterons by the high-energy pions, π + d → π + p + n, the polarization characteristics of produced protons are calculated. Using the vector nature of the Pomeron exchange, the general structure of all components of proton polarization vector is found for d (π, π p) n. By the Pomeron-photon analogy, the amplitude of the process P + d → n + p is approximated by the isoscalar contribution of four Born diagrams similar to the case of deuteron electrodisintegration. Unitarization of the amplitude is achieved by introducing in multipole amplitudes the corresponding phases of np-scattering. The numerical calculation of all components of the polarization vector of protons, produced in the case of noncomplanar kinematics of the reaction π + d → π + p + n, is realized

  2. Positive Correlation Between Academic Library Services and High-Impact Practices for

    Directory of Open Access Journals (Sweden)

    Saori Wendy Herman, MLIS, AHIP

    2016-03-01

    Full Text Available Objective – To investigate the perceived alignment between academic library services and high-impact practices (HIPs that affect student retention. Design – Survey questionnaire. Setting – Public comprehensive universities in the United States of America with a Carnegie classification of master’s level as of January 2013. Subjects – 68 library deans or directors out of the 271 who were originally contacted. Methods – The author used Qualtrics software to create a survey based on the HIPs, tested the survey for reliability, and then distributed it to 271 universities. Library services were grouped into 1 of 3 library scales: library collection, library instruction, or library facilities. The survey consisted of a matrix of 10 Likert-style questions addressing the perceived level of alignment between the library scales and the HIPs. Each question provided an opportunity for the respondent to enter a “brief description of support practices” (p 477. Additional demographic questions addressed the years of experience of the respondent, undergraduate student enrollment of the university, and whether librarians held faculty rank. Main Results – The author measured Pearson correlation coefficients and found a positive correlation between the library scales and the HIPs. All three library scales displayed a moderately strong positive correlation between first-year seminars and experiences (HIP 1, common intellectual experiences (HIP 2, writing-intensive courses (HIP 4, undergraduate research (HIP 6, diversity and global learning (HIP 7, service learning and community-based learning (HIP 8, internships (HIP 9, and capstone courses and projects (HIP 10. The library collections scale and library facilities scale displayed a moderately strong correlation with learning communities (HIP 3 and collaborative assignments and projects (HIP 5. The library instruction scale displayed a strong positive correlation with HIP 3 and a very strong

  3. Using constructivist teaching strategies in high school science classrooms to cultivate positive attitudes toward science

    Science.gov (United States)

    Heron, Lory Elen

    This study investigated the premise that the use of constructivist teaching strategies (independent variable) in high school science classrooms can cultivate positive attitudes toward science (dependent variable) in high school students. Data regarding the relationship between the use of constructivist strategies and change in student attitude toward science were collected using the Science Attitude Assessment Tool (SAAT) (Heron & Beauchamp, 1996). The format of this study used the pre-test, post-test, control group-experimental group design. The subjects in the study were high school students enrolled in biology, chemistry, or environmental science courses in two high schools in the western United States. Ten teachers and twenty-eight classes, involving a total of 249 students participated in the study. Six experimental group teachers and four control group teachers were each observed an average of six times using the Science Observation Guide (Chapman, 1995) to measure the frequency of observed constructivist behaviors. The mean for the control group teachers was 12.89 and the mean for experimental group teachers was 20.67; F(1, 8) = 16.2, p =.004, revealing teaching behaviors differed significantly between the two groups. After a four month experimental period, the pre-test and post-test SAAT scores were analyzed. Students received a score for their difference in positive attitude toward science. The null hypothesis stating there would be no change in attitude toward science as a subject, between students exposed to constructivist strategies, and students not exposed to constructivist strategies was rejected F(1, 247) = 8.04, p =.005. The control group had a generally higher reported grade in their last science class than the experimental group, yet the control group attitude toward science became more negative (-1.18) while attitude toward science in the experimental group became more positive (+1.34) after the four-month period. An analysis of positive

  4. Dependence of high order harmonics intensity on laser focal spot position in preformed plasma plumes

    International Nuclear Information System (INIS)

    Singhal, H.; Ganeev, R.; Naik, P. A.; Arora, V.; Chakravarty, U.; Gupta, P. D.

    2008-01-01

    The dependence of the high-order harmonic intensity on the laser focal spot position in laser produced plasma plumes is experimentally studied. High order harmonics up to the 59th order (λ∼13.5 nm) were generated by focusing 48 fs laser pulses from a Ti:sapphire laser system in silver plasma plume produced using 300 ps uncompressed laser radiation as the prepulse. The intensity of harmonics nearly vanished when the best focus was located in the plume center, whereas it peaked on either side with unequal intensity. The focal spot position corresponding to the peak harmonic intensity moved away from the plume center for higher order harmonics. The results are explained in terms of the variation of phase mismatch between the driving laser beam and harmonics radiation produced, relativistic drift of electrons, and defocusing effect due to radial ionization gradient in the plasma for different focal spot positions

  5. Observational study of differences in head position for high notes in famous classical and non-classical male singers.

    Science.gov (United States)

    Amarante Andrade, Pedro; Švec, Jan G

    2016-07-01

    Differences in classical and non-classical singing are due primarily to aesthetic style requirements. The head position can affect the sound quality. This study aimed at comparing the head position for famous classical and non-classical male singers performing high notes. Images of 39 Western classical and 34 non-classical male singers during live performances were obtained from YouTube. Ten raters evaluated the frontal rotational head position (depression versus elevation) and transverse head position (retraction versus protraction) visually using a visual analogue scale. The results showed a significant difference for frontal rotational head position. Most non-classical singers in the sample elevated their heads for high notes while the classical singers were observed to keep it around the neutral position. This difference may be attributed to different singing techniques and phonatory system adjustments utilized by each group.

  6. A synbio approach for selection of highly expressed gene variants in Gram-positive bacteria.

    Science.gov (United States)

    Ferro, Roberto; Rennig, Maja; Hernández-Rollán, Cristina; Daley, Daniel O; Nørholm, Morten H H

    2018-03-08

    The market for recombinant proteins is on the rise, and Gram-positive strains are widely exploited for this purpose. Bacillus subtilis is a profitable host for protein production thanks to its ability to secrete large amounts of proteins, and Lactococcus lactis is an attractive production organism with a long history in food fermentation. We have developed a synbio approach for increasing gene expression in two Gram-positive bacteria. First of all, the gene of interest was coupled to an antibiotic resistance gene to create a growth-based selection system. We then randomised the translation initiation region (TIR) preceding the gene of interest and selected clones that produced high protein titres, as judged by their ability to survive on high concentrations of antibiotic. Using this approach, we were able to significantly increase production of two industrially relevant proteins; sialidase in B. subtilis and tyrosine ammonia lyase in L. lactis. Gram-positive bacteria are widely used to produce industrial enzymes. High titres are necessary to make the production economically feasible. The synbio approach presented here is a simple and inexpensive way to increase protein titres, which can be carried out in any laboratory within a few days. It could also be implemented as a tool for applications beyond TIR libraries, such as screening of synthetic, homologous or domain-shuffled genes.

  7. High-intensity positive beams extracted from a compact double-chamber ion source

    International Nuclear Information System (INIS)

    Huck, H.; Somacal, H.; Di Gregorio, D.E.; Fernandez Niello, J.O.; Igarzabal, M.; Di Paolo, H.; Reinoso, M.

    2005-01-01

    This work presents the design and development of a simple ion source, the associated ion extraction optics, and the beam transport of a low-energy and high-current proton accelerator. In its actual version, the ion source can deliver positive proton currents up to 100 mA. This rather high beam current is achieved by adding a small ionization chamber between the discharge chamber containing the filament and the extraction electrode of the ion source. Different parameters of the ion source and the injection beam line are evaluated by means of computer simulations to optimize the beam production and transmission

  8. Mellin moments of the O({alpha}{sub s}{sup 3}) heavy flavor contributions to unpolarized deep-inelastic scattering at Q{sup 2} >> m{sup 2} and anomalous dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Bierenbaum, I.; Bluemlein, J.; Klein, S.

    2009-04-15

    We calculate the O({alpha}{sub s}{sup 3}) heavy flavor contributions to theWilson coefficients of the structure function F{sub 2}(x,Q{sup 2}) and the massive operator matrix elements (OMEs) for the twist-2 operators of unpolarized deeply inelastic scattering in the region Q{sup 2}>>m{sup 2}. The massive Wilson coefficients are obtained as convolutions of massive OMEs and the known light flavor Wilson coefficients. We also compute the massive OMEs which are needed to evaluate heavy flavor parton distributions in the variable flavor number scheme (VFNS) to 3-loop order. All contributions to the Wilson coefficients and operator matrix elements but the genuine constant terms at O({alpha}{sub s}{sup 3}) of the OMEs are derived in terms of quantities, which are known for general values in the Mellin variable N. For the operator matrix elements A{sup (3)}{sub Qg}, A{sup (3)}{sub gq,Q} and A{sup (3)}{sub gg,Q} the moments N=2 to 10, for A{sup (3),PS}{sub Qq} to N=12, and for A{sup (3),NS}{sub qq,Q}, A{sup (3),PS}{sub qq,Q}, A{sup (3),PS}{sub gq,Q} to N=14 are computed. These terms contribute to the light flavor +-combinations. For the flavor non-singlet terms, we calculate as well the odd moments N=1 to 13, corresponding to the light flavor --combinations. We also obtain the moments of the 3-loop anomalous dimensions, their color projections for the present processes respectively, in an independent calculation, which agree with the results given in the literature. (orig.)

  9. VERY LARGE ARRAY OBSERVATIONS OF DG TAU'S RADIO JET: A HIGHLY COLLIMATED THERMAL OUTFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, C.; Mutel, R. L.; Gayley, K. G. [Department of Physics and Astronomy, University of Iowa, Iowa City, Iowa 52240 (United States); Guedel, M. [Department of Astrophysics, University of Vienna, A-1180 Vienna (Austria); Ray, T. [Astronomy and Astrophysics Section, Dublin Institute for Advanced Studies, 31 Fitzwilliam Place, Dublin 2 (Ireland); Skinner, S. L. [Center for Astrophysics and Space Astronomy, University of Colorado, Boulder, CO 80309 (United States); Schneider, P. C. [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany)

    2013-03-20

    The active young protostar DG Tau has an extended jet that has been well studied at radio, optical, and X-ray wavelengths. We report sensitive new Very Large Array (VLA) full-polarization observations of the core and jet between 5 GHz and 8 GHz. Our high angular resolution observation at 8 GHz clearly shows an unpolarized inner jet with a size of 42 AU (0.''35) extending along a position angle similar to the optical-X ray outer jet. Using our nearly coeval 2012 VLA observations, we find a spectral index {alpha} = +0.46 {+-} 0.05, which combined with the lack of polarization is consistent with bremsstrahlung (free-free) emission, with no evidence for a non-thermal coronal component. By identifying the end of the radio jet as the optical depth unity surface, and calculating the resulting emission measure, we find that our radio results are in agreement with previous optical line studies of electron density and consequent mass-loss rate. We also detect a weak radio knot at 5 GHz located 7'' from the base of the jet, coincident with the inner radio knot detected by Rodriguez et al. in 2009 but at lower surface brightness. We interpret this as due to expansion of post-shock ionized gas in the three years between observations.

  10. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  11. Modelling and Control of Stepper Motors for High Accuracy Positioning Systems Used in Radioactive Environments

    CERN Document Server

    Picatoste Ruilope, Ricardo; Masi, Alessandro

    Hybrid Stepper Motors are widely used in open-loop position applications. They are the choice of actuation for the collimators in the Large Hadron Collider, the largest particle accelerator at CERN. In this case the positioning requirements and the highly radioactive operating environment are unique. The latter forces both the use of long cables to connect the motors to the drives which act as transmission lines and also prevents the use of standard position sensors. However, reliable and precise operation of the collimators is critical for the machine, requiring the prevention of step loss in the motors and maintenance to be foreseen in case of mechanical degradation. In order to make the above possible, an approach is proposed for the application of an Extended Kalman Filter to a sensorless stepper motor drive, when the motor is separated from its drive by long cables. When the long cables and high frequency pulse width modulated control voltage signals are used together, the electrical signals difer greatl...

  12. Polarized and unpolarized nucleon structure functions from lattice QCD

    International Nuclear Information System (INIS)

    Goeckeler, M.; Technische Hochschule Aachen; Horsley, R.; Humboldt-Universitaet, Berlin; Ilgenfritz, E.M.; Perlt, H.; Rakow, P.; Schierholz, G.; Forschungszentrum Juelich GmbH; Schiller, A.

    1995-06-01

    We report on a high statistics quenched lattice QCD calculation of the deep-inelastic structure functions F 1 , F 2 , g 1 and g 2 of the proton and neutron. The theoretical basis for the calculation is the operator product expansion. We consider the moments of the leading twist operators up to spin four. Using Wilson fermions the calculation is done for three values of K, and we perform the extrapolation to the chiral limit. The renormalization constants, which lead us from lattice to continuum operators, are calculated in perturbation theory to one loop order. (orig.)

  13. A high-efficiency positive (negative) surface ionization source for radioactive ion beam (abstract)a

    International Nuclear Information System (INIS)

    Alton, G.D.; Mills, G.D.

    1996-01-01

    A versatile, new concept, spherical-geometry, positive (negative) surface-ionization source has been designed and fabricated which will have the capability of generating both positive- and negative-ion beams without mechanical changes to the source. The source utilizes a highly permeable, high-work-function Ir ionizer (φ≡5.29 eV) for ionizing highly electropositive atoms/molecules; while for negative-surface ionization, the work function is lowered to φ≡1.43 eV by continually feeding cesium vapor through the ionizer matrix. The use of this technique for negative ion beam generation has the potential of overcoming the chronic poisoning effects experienced with LaB 6 while enhancing considerably the efficiency for negative surface ionization of atoms and molecules with intermediate electron affinities. The flexibility of operation in either mode makes it especially attractive for radioactive ion beam applications and, therefore, the source will be used as a complementary replacement for the high-temperature electron impact ionization sources presently in use at the Holifield radioactive beam facility. The design features and operational principles of the source will be described in this report. copyright 1996 American Institute of Physics

  14. A Novel, Aqueous Surface Treatment To Thermally Stabilize High Resolution Positive Photoresist Images*

    Science.gov (United States)

    Grunwald, John J.; Spencer, Allen C.

    1986-07-01

    The paper describes a new approach to thermally stabilize the already imaged profile of high resolution positive photoresists such as ULTRAMAC" PR-914. ***XD-4000, an aqueous emulsion of a blend of fluorine-bearing compounds is spun on top of the developed, positive photoresist-imaged wafer, and baked. This allows the photoresist to withstand temperatures up to at least 175 deg. C. while essentially maintaining vertical edge profiles. Also, adverse effects of "outgassing" in harsh environments, ie., plasma and ion implant are greatly minimized by allowing the high resolution imaged photoresist to be post-baked at "elevated" temperatures. Another type of product that accomplishes the same effect is ***XD-4005, an aqueous emulsion of a high temperature-resistant polymer. While the exact mechanism is yet to be identified, it is postulated that absorption of the "polymeric" species into the "skin" of the imaged resist forms a temperature resistant "envelope", thereby allowing high resolution photoresists to also serve in a "high temperature" mode, without reticulation, or other adverse effects due to thermal degradation. SEM's are presented showing imaged ULTRAMAC" PR-914 and ULTRAMAC" **EPA-914 geometries coated with XD-4000 or XD-4005 and followed by plasma etched oxide,polysilicon and aluminum. Selectivity ratios are compared with and without the novel treatment and are shown to be significantly better with the treatment. The surface-treated photoresist for thermal resistance remains easily strippable in solvent-based or plasma media, unlike photoresists that have undergone "PRIST" or other gaseous thermal stabilization methods.

  15. Development of a Sweetness Sensor for Aspartame, a Positively Charged High-Potency Sweetener

    Directory of Open Access Journals (Sweden)

    Masato Yasuura

    2014-04-01

    Full Text Available Taste evaluation technology has been developed by several methods, such as sensory tests, electronic tongues and a taste sensor based on lipid/polymer membranes. In particular, the taste sensor can individually quantify five basic tastes without multivariate analysis. However, it has proven difficult to develop a sweetness sensor, because sweeteners are classified into three types according to the electric charges in an aqueous solution; that is, no charge, negative charge and positive charge. Using membrane potential measurements, the taste-sensing system needs three types of sensor membrane for each electric charge type of sweetener. Since the commercially available sweetness sensor was only intended for uncharged sweeteners, a sweetness sensor for positively charged high-potency sweeteners such as aspartame was developed in this study. Using a lipid and plasticizers, we fabricated various lipid/polymer membranes for the sweetness sensor to identify the suitable components of the sensor membranes. As a result, one of the developed sensors showed responses of more than 20 mV to 10 mM aspartame and less than 5 mV to any other taste. The responses of the sensor depended on the concentration of aspartame. These results suggested that the developed sweetness sensor had high sensitivity to and high selectivity for aspartame.

  16. Development of a sweetness sensor for aspartame, a positively charged high-potency sweetener.

    Science.gov (United States)

    Yasuura, Masato; Tahara, Yusuke; Ikezaki, Hidekazu; Toko, Kiyoshi

    2014-04-23

    Taste evaluation technology has been developed by several methods, such as sensory tests, electronic tongues and a taste sensor based on lipid/polymer membranes. In particular, the taste sensor can individually quantify five basic tastes without multivariate analysis. However, it has proven difficult to develop a sweetness sensor, because sweeteners are classified into three types according to the electric charges in an aqueous solution; that is, no charge, negative charge and positive charge. Using membrane potential measurements, the taste-sensing system needs three types of sensor membrane for each electric charge type of sweetener. Since the commercially available sweetness sensor was only intended for uncharged sweeteners, a sweetness sensor for positively charged high-potency sweeteners such as aspartame was developed in this study. Using a lipid and plasticizers, we fabricated various lipid/polymer membranes for the sweetness sensor to identify the suitable components of the sensor membranes. As a result, one of the developed sensors showed responses of more than 20 mV to 10 mM aspartame and less than 5 mV to any other taste. The responses of the sensor depended on the concentration of aspartame. These results suggested that the developed sweetness sensor had high sensitivity to and high selectivity for aspartame.

  17. Drell-Yan lepton pair production at high energies in the k{sub T}-factorization approach

    Energy Technology Data Exchange (ETDEWEB)

    Lipatov, A.V.; Malyshev, M.A.; Zotov, N.P. [M.V. Lomonosov Moscow State Univ. (Russian Federation). D.V. Skobeltsyn Inst. of Nuclear Physics

    2011-11-15

    In the framework of the k{sub T}-factorization approach, the production of unpolarized Drell-Yan lepton pair at high energies is studied. The consideration is based on the O({alpha}) and O({alpha}{alpha}{sub s}) off-shell partonic matrix elements with virtual photon {gamma}{sup *} and Z boson exchange. The calculations include leptonic decays of Z bosons with full spin correlations as well as {gamma}{sup *}-Z interference. The unintegrated parton densities in a proton are determined by the Kimber-Martin-Ryskin prescription. Our numerical predictions are compared with the data taken by the D diameter, CDF and CMS collaborations at the Tevatron and LHC energies. Special attention is put on the specific angular distributions measured very recently by the CDF collaboration for the first time. (orig.)

  18. Highly Educated Taiwanese Women Seeking a Self-Acceptable Social Position in Finland

    OpenAIRE

    Chang, Chia-Chien

    2014-01-01

    The main purpose of the study was to investigate how highly educated (university-educated) Taiwanese women acquire, transfer and transform their cultural capital through their middle-class habitus to seek a self-acceptable social position in Finnish society. The study s theoretical frameworks have drawn on Bourdieu s concept of habitus, capital, field, and practice, and incorporate an intersectionality perspective into the data analysis. This study employed a feminist standpoint epistemo...

  19. High resolution, position sensitive detector for energetic particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, E P [Charles Evans and Associates, Redwood City, CA (United States); Strathman, M D [Charles Evans and Associates, Redwood City, CA (United States); Reed, D A [Charles Evans and Associates, Redwood City, CA (United States); Odom, R W [Charles Evans and Associates, Redwood City, CA (United States); Morse, D H [Sandia National Labs., Livermore, CA (United States); Pontau, A E [Sandia National Labs., Livermore, CA (United States)

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10[sup 10]), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 [mu]m for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 [mu]m) with an image resolution of better than 0.5 [mu]m has since been developed and its design is presented. (orig.)

  20. Linearly Polarized Gluons and the Higgs Transverse Momentum Distribution

    NARCIS (Netherlands)

    Boer, Daniel; den Dunnen, Wilco J.; Pisano, Cristian; Schlegel, Marc; Vogelsang, Werner

    2012-01-01

    We study how gluons carrying linear polarization inside an unpolarized hadron contribute to the transverse momentum distribution of Higgs bosons produced in hadronic collisions. They modify the distribution produced by unpolarized gluons in a characteristic way that could be used to determine

  1. High dose-rate brachytherapy source position quality assurance using radiochromic film

    International Nuclear Information System (INIS)

    Evans, M.D.C.; Devic, S.; Podgorsak, E.B.

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance

  2. High dose-rate brachytherapy source localization: positional resolution using a diamond detector

    International Nuclear Information System (INIS)

    Nakano, T; Suchowerska, N; Bilek, M M; McKenzie, D R; Ng, N; Kron, T

    2003-01-01

    A potential real-time source position verification process for high dose-rate (HDR) brachytherapy treatment is described. This process is intended to provide immediate confirmation that a treatment is proceeding according to plan, so that corrective action can be taken if necessary. We show that three dosimeters are in principle sufficient and demonstrate the feasibility of the process using a diamond detector and an Ir-192 source. An error analysis including all identified sources of error shows that this detector is capable of locating the distance to the source to within 2 mm for distances up to 12 cm. This positional accuracy is less than the diameter of typical HDR catheters indicating that a diamond detector can be used to accurately determine the distance to the source. The uncertainty in the distance is found to increase with distance

  3. High Accuracy Positioning using Jet Thrusters for Quadcopter

    Directory of Open Access Journals (Sweden)

    Pi ChenHuan

    2018-01-01

    Full Text Available A quadcopter is equipped with four additional jet thrusters on its horizontal plane and vertical to each other in order to improve the maneuverability and positioning accuracy of quadcopter. A dynamic model of the quadcopter with jet thrusters is derived and two controllers are implemented in simulation, one is a dual loop state feedback controller for pose control and another is an auxiliary jet thruster controller for accurate positioning. Step response simulations showed that the jet thruster can control the quadcopter with less overshoot compared to the conventional one. Over 10s loiter simulation with disturbance, the quadcopter with jet thruster decrease 85% of RMS error of horizontal disturbance compared to a conventional quadcopter with only a dual loop state feedback controller. The jet thruster controller shows the possibility for further accurate in the field of quadcopter positioning.

  4. Crash safety concerns for out-of-position occupant postures: A look toward safety in highly automated vehicles.

    Science.gov (United States)

    McMurry, Timothy L; Poplin, Gerald S; Shaw, Greg; Panzer, Matthew B

    2018-04-09

    Highly automated vehicle occupants will all be passengers and may be free to ride while in postures for which existing occupant safety systems such as seat belts and airbags were not originally designed. These occupants could therefore face increased risk of injury when a crash occurs. Given that current vehicles are capable of supporting a variety of occupant postures outside of the normal design position, such as reclined or turned passengers, an evaluation of current field data was performed to better understand the risks of being out of position. We investigated the frequency, demographics, and injury outcomes for out-of-position occupants using NASS-CDS. A matched analysis was performed to compare injury outcomes for out-of-position passengers with in-position drivers involved in similar crashes. Finally, case studies for out-of-position occupants were examined in the Crash Injury Research (CIREN) database. Only 0.5% of occupants in NASS-CDS with a coded posture were out of position at the time of crash. Of the out-of-position occupants, being turned or seated sideways was almost as likely as being reclined. Out-of-position occupants were younger and less likely to be belted than their in-position counterparts. Analysis of the injury data indicated a trend that being out of position was associated with an elevated risk for serious injury. However, the number of out-of-position occupants was too small to provide a definitive or statistically significant conclusion on injury outcome. Though highly automated vehicles may eventually reduce the number of crashes and traffic fatalities in the future, there will be a transition period when these vehicles remain at risk from collisions with human-driven vehicles. These crashes could cause higher than anticipated rates of injury if occupants are less likely to be belted or tend to be in positions for which restraints are not optimized. This study highlights the need for future research on occupant response and

  5. Presence of High-Risk HPV mRNA in Relation to Future High-Grade Lesions among High-Risk HPV DNA Positive Women with Minor Cytological Abnormalities.

    Directory of Open Access Journals (Sweden)

    Hanna Johansson

    Full Text Available Continuous expression of E6- and E7-oncogenes of high-risk human papillomavirus (HPV types is necessary for the development and maintenance of the dysplastic phenotype. The aim of the study was to determine the sensitivity and specificity of the APTIMA HPV mRNA assay (Hologic in predicting future development of high-grade cervical intraepithelial neoplasia (CIN among high-risk HPV-DNA-positive women with atypical squamous cells of undetermined significance (ASCUS or low-grade squamous epithelial lesion (LSIL cytology.Archived SurePath cervical samples of women ≥ 35 years of age with high-risk HPV DNA-positive ASCUS (n = 211 or LSIL, (n = 131 were tested for the presence of high-risk HPV E6/E7 mRNA using the APTIMA HPV assay, and the women were monitored for development of histopathologically verified CIN2+.Twenty-nine percent (61/211 of the women in the ASCUS group, and 34.3% (45/131 in the LSIL group developed CIN2+ within 4.5 years of follow-up. The prevalence of HPV mRNA was 90.0% (95% CI 85.9-94.0 among women with ASCUS and 95.4% (95% CI 91.8-99.0 among women with LSIL. The presence of HPV E6/E7 mRNA was associated with future development of CIN2+ among women with ASCUS and LSIL (p=0.02. The mRNA assay demonstrated high sensitivity in predicting future CIN2+ and CIN3 for index ASCUS (96.7%; 95% CI 87.6-99.4 and 100%; 95% CI 82.2-100, respectively and LSIL (97.8%, 95% CI 86.8-99.9 and 100%, 95% CI 79.9-100, respectively. The corresponding specificity was low, 12.7% (95% CI 7.9-19.3 and 5.8% (95% CI 2.2-13.6, for future CIN2+, respectively. The negative predictive value of the HPV mRNA assay for detecting future CIN3 was 100%, since no mRNA-negative woman developed CIN3 (0/27 as compared to 13.6% (43/315 of the mRNA-positive women (p = 0.03.The APTIMA mRNA assay demonstrated high sensitivity but low specificity in predicting future CIN2+ among women with minor cytological abnormalities. The assay had high negative predictive value for future

  6. Presence of High-Risk HPV mRNA in Relation to Future High-Grade Lesions among High-Risk HPV DNA Positive Women with Minor Cytological Abnormalities

    Science.gov (United States)

    Johansson, Hanna; Bjelkenkrantz, Kaj; Darlin, Lotten; Dilllner, Joakim; Forslund, Ola

    2015-01-01

    Objective Continuous expression of E6- and E7-oncogenes of high-risk human papillomavirus (HPV) types is necessary for the development and maintenance of the dysplastic phenotype. The aim of the study was to determine the sensitivity and specificity of the APTIMA HPV mRNA assay (Hologic) in predicting future development of high-grade cervical intraepithelial neoplasia (CIN) among high-risk HPV-DNA-positive women with atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous epithelial lesion (LSIL) cytology. Methods Archived SurePath cervical samples of women ≥ 35 years of age with high-risk HPV DNA-positive ASCUS (n = 211) or LSIL, (n = 131) were tested for the presence of high-risk HPV E6/E7 mRNA using the APTIMA HPV assay, and the women were monitored for development of histopathologically verified CIN2+. Results Twenty-nine percent (61/211) of the women in the ASCUS group, and 34.3% (45/131) in the LSIL group developed CIN2+ within 4.5 years of follow-up. The prevalence of HPV mRNA was 90.0% (95% CI 85.9-94.0) among women with ASCUS and 95.4% (95% CI 91.8-99.0) among women with LSIL. The presence of HPV E6/E7 mRNA was associated with future development of CIN2+ among women with ASCUS and LSIL (p=0.02). The mRNA assay demonstrated high sensitivity in predicting future CIN2+ and CIN3 for index ASCUS (96.7%; 95% CI 87.6-99.4 and 100%; 95% CI 82.2-100, respectively) and LSIL (97.8%, 95% CI 86.8-99.9 and 100%, 95% CI 79.9-100, respectively). The corresponding specificity was low, 12.7% (95% CI 7.9-19.3) and 5.8% (95% CI 2.2-13.6), for future CIN2+, respectively. The negative predictive value of the HPV mRNA assay for detecting future CIN3 was 100%, since no mRNA-negative woman developed CIN3 (0/27) as compared to 13.6% (43/315) of the mRNA-positive women (p = 0.03). Conclusion The APTIMA mRNA assay demonstrated high sensitivity but low specificity in predicting future CIN2+ among women with minor cytological abnormalities. The assay had

  7. High amino acid diversity and positive selection at a putative coral immunity gene (tachylectin-2

    Directory of Open Access Journals (Sweden)

    Hellberg Michael E

    2010-05-01

    Full Text Available Abstract Background Genes involved in immune functions, including pathogen recognition and the activation of innate defense pathways, are among the most genetically variable known, and the proteins that they encode are often characterized by high rates of amino acid substitutions, a hallmark of positive selection. The high levels of variation characteristic of immunity genes make them useful tools for conservation genetics. To date, highly variable immunity genes have yet to be found in corals, keystone organisms of the world's most diverse marine ecosystem, the coral reef. Here, we examine variation in and selection on a putative innate immunity gene from Oculina, a coral genus previously used as a model for studies of coral disease and bleaching. Results In a survey of 244 Oculina alleles, we find high nonsynonymous variation and a signature of positive selection, consistent with a putative role in immunity. Using computational protein structure prediction, we generate a structural model of the Oculina protein that closely matches the known structure of tachylectin-2 from the Japanese horseshoe crab (Tachypleus tridentatus, a protein with demonstrated function in microbial recognition and agglutination. We also demonstrate that at least three other genera of anthozoan cnidarians (Acropora, Montastrea and Nematostella possess proteins structurally similar to tachylectin-2. Conclusions Taken together, the evidence of high amino acid diversity, positive selection and structural correspondence to the horseshoe crab tachylectin-2 suggests that this protein is 1 part of Oculina's innate immunity repertoire, and 2 evolving adaptively, possibly under selective pressure from coral-associated microorganisms. Tachylectin-2 may serve as a candidate locus to screen coral populations for their capacity to respond adaptively to future environmental change.

  8. Right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch

    International Nuclear Information System (INIS)

    Ahn, Kyung-Sik; Yong, Hwan Seok; Woo, Ok Hee; Kang, Eun-Young; Lee, Joo-Won

    2007-01-01

    We present a rare case of right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch. A 7-month-old boy presented with a cardiac murmur. Cardiac situs was normal and there was no evidence of an intracardiac shunt or patent ductus arteriosus. MR aortography revealed a right aortic arch that was high-positioned, tortuous and narrowed. This right aortic arch crossed the midline behind the oesophagus and continued as a left-sided descending aorta. The left common carotid and subclavian arteries arose from a large branching vascular structure that derived from the top of the left-sided descending aorta. The right common carotid artery arose from the ascending aorta. The proximal portion of the right common carotid artery showed very severe stenosis and poststenotic dilatation. The right subclavian artery originated distal to the narrowed and tortuous segment of the aortic arch. (orig.)

  9. Design and performance of a high resolution, low latency stripline beam position monitor system

    Science.gov (United States)

    Apsimon, R. J.; Bett, D. R.; Blaskovic Kraljevic, N.; Burrows, P. N.; Christian, G. B.; Clarke, C. I.; Constance, B. D.; Dabiri Khah, H.; Davis, M. R.; Perry, C.; Resta López, J.; Swinson, C. J.

    2015-03-01

    A high-resolution, low-latency beam position monitor (BPM) system has been developed for use in particle accelerators and beam lines that operate with trains of particle bunches with bunch separations as low as several tens of nanoseconds, such as future linear electron-positron colliders and free-electron lasers. The system was tested with electron beams in the extraction line of the Accelerator Test Facility at the High Energy Accelerator Research Organization (KEK) in Japan. It consists of three stripline BPMs instrumented with analogue signal-processing electronics and a custom digitizer for logging the data. The design of the analogue processor units is presented in detail, along with measurements of the system performance. The processor latency is 15.6 ±0.1 ns . A single-pass beam position resolution of 291 ±10 nm has been achieved, using a beam with a bunch charge of approximately 1 nC.

  10. Chlamydia positivity in New Orleans public high schools, 1996-2005: implications for clinical and public health practices.

    Science.gov (United States)

    Nsuami, M Jacques; Nsa, Musheni; Brennan, Christine; Cammarata, Catherine L; Martin, David H; Taylor, Stephanie N

    2013-01-01

    To describe the trends in chlamydia positivity among New Orleans high school students tested in a schoolwide screening between 1996 and 2005, and to determine factors associated with chlamydia positivity among students during the 10-year period. Between school years 1995-1996 and 2004-2005, students in New Orleans public high schools were tested for chlamydia using nucleic acid amplification tests (NAAT) in urine specimens (LCx assay until 1999-2000; BD assay from 2000-2001 to 2004-2005). For each year, we calculated chlamydia positivity by dividing the number of students testing positive by the total number of students tested. Data were analyzed separately by gender. Logistic regressions were performed to determine independent predictors of chlamydia positivity during the 10-year period. Between 1996 and 2005, the average chlamydia positivity was 7.0% (95% confidence interval 6.6-7.4) in boys and 13.1% (95% confidence interval 12.6-13.7) in girls (P New Orleans school-age adolescent population. Any benefit of screening on individuals tested was likely to be mitigated by participants' uninterrupted social interactions with the dynamic forces that sustain the sexual transmission of chlamydia in the population. Copyright © 2013 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  11. A Highly Reliable and Cost-Efficient Multi-Sensor System for Land Vehicle Positioning

    Directory of Open Access Journals (Sweden)

    Xu Li

    2016-05-01

    Full Text Available In this paper, we propose a novel positioning solution for land vehicles which is highly reliable and cost-efficient. The proposed positioning system fuses information from the MEMS-based reduced inertial sensor system (RISS which consists of one vertical gyroscope and two horizontal accelerometers, low-cost GPS, and supplementary sensors and sources. First, pitch and roll angle are accurately estimated based on a vehicle kinematic model. Meanwhile, the negative effect of the uncertain nonlinear drift of MEMS inertial sensors is eliminated by an H∞ filter. Further, a distributed-dual-H∞ filtering (DDHF mechanism is adopted to address the uncertain nonlinear drift of the MEMS-RISS and make full use of the supplementary sensors and sources. The DDHF is composed of a main H∞ filter (MHF and an auxiliary H∞ filter (AHF. Finally, a generalized regression neural network (GRNN module with good approximation capability is specially designed for the MEMS-RISS. A hybrid methodology which combines the GRNN module and the AHF is utilized to compensate for RISS position errors during GPS outages. To verify the effectiveness of the proposed solution, road-test experiments with various scenarios were performed. The experimental results illustrate that the proposed system can achieve accurate and reliable positioning for land vehicles.

  12. A novel diamond-based beam position monitoring system for the High Radiation to Materials facility at CERN SPS

    CERN Document Server

    AUTHOR|(CDS)2092886; Höglund, Carina

    The High Radiation to Materials facility employs a high intensity pulsed beam imposing several challenges on the beam position monitors. Diamond has been shown to be a resilient material with its radiation hardness and mechanical strength, while it is also simple due to its wide bandgap removing the need for doping. A new type of diamond based beam position monitor has been constructed, which includes a hole in the center of the diamond where the majority of the beam is intended to pass through. This increases the longevity of the detectors as well as allowing them to be used for high intensity beams. The purpose of this thesis is to evaluate the performance of the detectors in the High Radiation to Materials facility for various beam parameters, involving differences in position, size, bunch intensity and bunch number. A prestudy consisting of calibration of the detectors using single incident particles is also presented. The detectors are shown to work as intended after a recalibration of the algorithm, alb...

  13. Nanoscale Soldering of Positioned Carbon Nanotubes using Highly Conductive Electron Beam Induced Gold Deposition

    DEFF Research Database (Denmark)

    Madsen, Dorte Nørgaard; Mølhave, Kristian; Mateiu, Ramona Valentina

    2003-01-01

    We have developed an in-situ method for controlled positioning of carbon nanotubes followed by highly conductive contacting of the nanotubes, using electron beam assisted deposition of gold. The positioning and soldering process takes place inside an Environmental Scanning Electron Microscope (E...... in a carbon matrix. Nanoscale soldering of multi-walled carbon nanotubes (MWNT) onto microelectrodes was achieved by deposition of a conducting gold line across a contact point between nanotube and electrode. The solderings were found to be mechanically stronger than the carbon nanotubes. We have positioned...... MWNTs to bridge the gap between two electrodes, and formed soldering bonds between the tube and each of the electrodes. All nanotube bridges showed ohmic resistances in the range 10-30 kΩ. We observed no increase in resistance after exposing the MWNT bridge to air for days....

  14. Indoor high precision three-dimensional positioning system based on visible light communication using modified genetic algorithm

    Science.gov (United States)

    Chen, Hao; Guan, Weipeng; Li, Simin; Wu, Yuxiang

    2018-04-01

    To improve the precision of indoor positioning and actualize three-dimensional positioning, a reversed indoor positioning system based on visible light communication (VLC) using genetic algorithm (GA) is proposed. In order to solve the problem of interference between signal sources, CDMA modulation is used. Each light-emitting diode (LED) in the system broadcasts a unique identity (ID) code using CDMA modulation. Receiver receives mixed signal from every LED reference point, by the orthogonality of spreading code in CDMA modulation, ID information and intensity attenuation information from every LED can be obtained. According to positioning principle of received signal strength (RSS), the coordinate of the receiver can be determined. Due to system noise and imperfection of device utilized in the system, distance between receiver and transmitters will deviate from the real value resulting in positioning error. By introducing error correction factors to global parallel search of genetic algorithm, coordinates of the receiver in three-dimensional space can be determined precisely. Both simulation results and experimental results show that in practical application scenarios, the proposed positioning system can realize high precision positioning service.

  15. Design and performance of a high resolution, low latency stripline beam position monitor system

    Directory of Open Access Journals (Sweden)

    R. J. Apsimon

    2015-03-01

    Full Text Available A high-resolution, low-latency beam position monitor (BPM system has been developed for use in particle accelerators and beam lines that operate with trains of particle bunches with bunch separations as low as several tens of nanoseconds, such as future linear electron-positron colliders and free-electron lasers. The system was tested with electron beams in the extraction line of the Accelerator Test Facility at the High Energy Accelerator Research Organization (KEK in Japan. It consists of three stripline BPMs instrumented with analogue signal-processing electronics and a custom digitizer for logging the data. The design of the analogue processor units is presented in detail, along with measurements of the system performance. The processor latency is 15.6±0.1  ns. A single-pass beam position resolution of 291±10  nm has been achieved, using a beam with a bunch charge of approximately 1 nC.

  16. Heavy-light fermion mixtures at unitarity

    Energy Technology Data Exchange (ETDEWEB)

    Gezerlis, Alexandros [Los Alamos National Laboratory; Carlson, Joseph [Los Alamos National Laboratory; Gandol, S [UNIV. ILL; Schmidt, E [ITALY

    2009-01-01

    We investigate fermion pairing in the unitary regime for a mass ratio corresponding to a {sup 6}Li-{sup 40}K mixture using quantum Monte Carlo methods. The ground-state energy and the average light- and heavy-particle excitation spectrum for the unpolarized superfluid state are nearly independent of the mass ratio. In the majority light system, the polarized superfluid is close to the energy of a phase separated mixture of nearly fully polarized normal and unpolarized superfluid. For a majority of heavy particles, we find an energy minimum for a normal state with a ratio of {approx}3:1 heavy to light particles. A slight increase in attraction to k{sub F}a{approx}2.5 yields a ground state energy of nearly zero for this ratio. A cold unpolarized system in a harmonic trap at unitarity should phase separate into three regions, with a shell of unpolarized superfluid in the middle.

  17. Some developments in polarized ion sources

    International Nuclear Information System (INIS)

    Witteveen, G.J.

    1979-01-01

    Investigations concerning an atomic beam source are presented and a new polarized ion source of a more universal type is introduced. Polarized and unpolarized beams of positively or negatively charged ions can be produced with this new version and the theoretical limits are a polarized negative hydrogen ion beam with an intensity of about 1 mH and a polarized proton beam with an intensity of 10 mH. (C.F.)

  18. Anti-ATLA (antibody to adult T-cell leukemia virus-associated antigen), highly positive in OKT4-positive mature T-cell malignancies.

    Science.gov (United States)

    Tobinai, K; Nagai, M; Setoya, T; Shibata, T; Minato, K; Shimoyama, M

    1983-01-01

    Serum or plasma specimens from 252 patients with lymphoid malignancies were screened for reactivity with adult T-cell leukemia virus-associated antigen (ATLA), and the relationship between the immunologic phenotype of the tumor cells and ATLA reactivity was determined. Anti-ATLA antibodies were found in 24 (29.3%) of 82 patients with T-cell malignancy. In contrast, the antibodies were found in none of the 106 patients with B-cell malignancy and only rarely in patients with other lymphoid malignancies without blood transfusions. Among the patients with T-cell malignancy, anti-ATLA antibodies were found in 23 (45.1%) of the 51 patients with OKT4-positive mature T-cell (inducer/helper T-cell) malignancy, but in none of the patients with T-cell malignancy of pre-T, thymic T-cell or OKT8-positive mature T-cell (suppressor/cytotoxic T-cell) phenotype. Furthermore, among the OKT4-positive mature T-cell malignancies, the antibodies were found in 16 (84.2%) of 19 patients with ATL and in 5 (27.8%) of 18 patients with mature (peripheral) T-cell lymphoma, in none of four with typical T-chronic lymphocytic leukemia, in one of nine with mycosis fungoides and in the one patient with small-cell variant of Sézary's syndrome. These results suggest that anti-ATLA positive T-cell malignancies with OKT4-positive mature T-cell phenotype must be the same disease, because it is highly possible that they have the same etiology and the same cellular origin. In the atypical cases, it seems necessary to demonstrate monoclonal integration of proviral DNA of ATLV or HTLV into the tumor cells in order to establish the final diagnosis of ATL.

  19. Fusion with highly spin polarized HD and D2

    International Nuclear Information System (INIS)

    Honig, A.; Letzring, S.; Skupsky, S.

    1993-01-01

    Our experimental efforts over the past 5 years have been aimed at cazrying out ICF shots with spin-polarized 0 fuel. We successfully prepared polarized 0 in HD, and solved the problems of loading target shells with our carefully prepared isotopic -rnixt.l.l?-es, polarizing them so that the 0 polarization remains metastably frozen-in for about half a day, and carrying out the various cold transfer requirements at Syracuse, where the target is prepared, and at Rochester, where the cold target is inserted fusion chamber. Upon shooting the accurately positioned unpolarized high density cold target, no neutron yield was observed. Inspection inside the OMEGA tank after the shot indicated the absence of neutron yield was dus to mal-timing or insufficient retraction rate of OMEGA'S fast shroud mechanism, resulting in interception of at least 20 of the 24 laser beams by the faulty shroud. In spits of this, all alements of the complex experiment we originally undertook have been successfully demonstrated, and the cold retrieval concepts and methods we developed are being utilized on the ICF upgrades at Rochester and at Livermore. In addition to the solution of the interface problems, we obtained novel results on polymer shell characteristics at low temperatures, and continuation of these experiments is c = ently supported by KLUP. Extensive additional mappings were ca=ied out of nuclear spin relaxation rates of H and D in solid HD in the temperature-magnetic field rangs of 0.01 to 4.2K and 0 - 13 Tesla. New phenomena were discovered, such as association of impurity clustering with very low temperature motion, and inequality of the growth-rate and decay-rate of the magnetization

  20. An Integrated GNSS/INS/LiDAR-SLAM Positioning Method for Highly Accurate Forest Stem Mapping

    Directory of Open Access Journals (Sweden)

    Chuang Qian

    2016-12-01

    Full Text Available Forest mapping, one of the main components of performing a forest inventory, is an important driving force in the development of laser scanning. Mobile laser scanning (MLS, in which laser scanners are installed on moving platforms, has been studied as a convenient measurement method for forest mapping in the past several years. Positioning and attitude accuracies are important for forest mapping using MLS systems. Inertial Navigation Systems (INSs and Global Navigation Satellite Systems (GNSSs are typical and popular positioning and attitude sensors used in MLS systems. In forest environments, because of the loss of signal due to occlusion and severe multipath effects, the positioning accuracy of GNSS is severely degraded, and even that of GNSS/INS decreases considerably. Light Detection and Ranging (LiDAR-based Simultaneous Localization and Mapping (SLAM can achieve higher positioning accuracy in environments containing many features and is commonly implemented in GNSS-denied indoor environments. Forests are different from an indoor environment in that the GNSS signal is available to some extent in a forest. Although the positioning accuracy of GNSS/INS is reduced, estimates of heading angle and velocity can maintain high accurate even with fewer satellites. GNSS/INS and the LiDAR-based SLAM technique can be effectively integrated to form a sustainable, highly accurate positioning and mapping solution for use in forests without additional hardware costs. In this study, information such as heading angles and velocities extracted from a GNSS/INS is utilized to improve the positioning accuracy of the SLAM solution, and two information-aided SLAM methods are proposed. First, a heading angle-aided SLAM (H-aided SLAM method is proposed that supplies the heading angle from GNSS/INS to SLAM. Field test results show that the horizontal positioning accuracy of an entire trajectory of 800 m is 0.13 m and is significantly improved (by 70% compared to that

  1. A high accuracy algorithm of displacement measurement for a micro-positioning stage

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2017-05-01

    Full Text Available A high accuracy displacement measurement algorithm for a two degrees of freedom compliant precision micro-positioning stage is proposed based on the computer micro-vision technique. The algorithm consists of an integer-pixel and a subpixel matching procedure. Series of simulations are conducted to verify the proposed method. The results show that the proposed algorithm possesses the advantages of high precision and stability, the resolution can attain to 0.01 pixel theoretically. In addition, the consuming time is reduced about 6.7 times compared with the classical normalized cross correlation algorithm. To validate the practical performance of the proposed algorithm, a laser interferometer measurement system (LIMS is built up. The experimental results demonstrate that the algorithm has better adaptability than that of the LIMS.

  2. Time-course of attentional bias for positive social words in individuals with high and low social anxiety.

    Science.gov (United States)

    Yu, Hongyu; Li, Songwei; Qian, Mingyi; Yang, Peng; Wang, Xiaoling; Lin, Muyu; Yao, Nisha

    2014-07-01

    Although accumulating research demonstrates the association between attentional bias and social anxiety, the bias for positive stimuli has so far not been adequately studied. The aim is to investigate the time-course of attentional bias for positive social words in participants with high and low social anxiety. In a modified dot-probe task, word-pairs of neutral and positive social words were randomly presented for 100, 500, and 1250 milliseconds in a nonclinical sample of students to test their attentional bias. Non-significant interaction of Group × Exposure Duration was found. However, there was a significant main effect of group, with significantly different response latencies between the high social anxiety (HSA) and low social anxiety (LSA) groups in the 100 ms condition, without for 500 or 1250 ms. With respect to attentional bias, the LSA group showed enhanced preferential attention for positive social words to which the HSA group showed avoidance in the 100 ms condition. In the 500 ms condition, preferential attention to positive social words was at trend in the LSA group, relative to the HSA group. Neither group showed attentional bias in the 1250 ms condition. These findings extend recent research about the attention training program and add to the empirical literature suggesting that the initial avoidance of positive stimuli may contribute to maintaining social anxiety.

  3. Evaluation of the relationship between smear positivity and high-resolution CT findings in children with pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Bolursaz, Mohammad Reza; Mehrian, Payam; Aghahosseini, Farahnaz; Lotfian, Ferial; Khalilzadeh, Soheila; Baghaie, Nooshin; Hassanzad, Maryam; Velayati, Ali Akbar

    2014-01-01

    The aim of this study is to find a relationship between the radiological manifestations of childhood tuberculosis on a high-resolution computed tomography (HRCT) and the results of sputum smear. This study aims to propose an alternative indicator of infectivity in terms of prevention of disease transmission through selective isolation policy in children whose clinical condition is highly suggestive of tuberculosis. This retrospective comparative study was performed on 95 children under 15 years of age diagnosed with tuberculosis based on both WHO criteria and positive sputum culture for mycobacterium Tuberculosis. The children were admitted for TB screening in the pediatric department of national research institute of tuberculosis and lung disease (NRITLD) between 2008–2012. Direct smear collected from sputum or gastric lavage, as well as HRCT were performed in all children prior to administration of medical therapy. Children were divided into 2 groups based on positive and negative smear results. HRCT abnormalities, as well as their anatomical distribution were compared between these 2 groups using multivariate analytic model. The most prevalent abnormalities in the positive smear group were consolidation, tree-in-bud pattern, upper lobe nodular infiltration and cavitation. The negative smear group featured lymphadenopathy, consolidation, collapse and nodular infiltration in the upper lobe. Cavity, tree- in-bud pattern and upper lobe nodular infiltration were highly associated with smear positivity in children. Conversely, lymphadenopathy and collapse had significant association with a negative smear. This study revealed that cavity, tree-in-bud and upper lobe nodular infiltration has significant association with smear positivity in childhood tuberculosis. On the other hand, lymphadenopathy and collapse were closely associated with smear negativity in this age group. It was also demonstrated that children with a positive smear most likely presented with

  4. Anticipation of high arousal aversive and positive movie clips engages common and distinct neural substrates.

    Science.gov (United States)

    Greenberg, Tsafrir; Carlson, Joshua M; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne

    2015-04-01

    The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, 'uncertain' (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of 'uncertain' clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  5. The method to evaluate the position error in graphic positioning technology

    Institute of Scientific and Technical Information of China (English)

    Huiqing Lu(卢慧卿); Baoguang Wang(王宝光); Lishuang Liu(刘力双); Yabiao Li(李亚标)

    2004-01-01

    In the measurement of automobile body-in-white, it has been widely studied to position the two dimensional(2D)visual sensors with high precision. In this paper a graphic positioning method is proposed,a hollow tetrahedron is used for a positioning target to replace all the edges of a standard automobile body.A 2D visual sensor can be positioned through adjusting two triangles to be superposed on a screen of the computer, so it is very important to evaluate the superposition precision of the two triangles. Several methods are discussed and the least square method is adopted at last, it makes the adjustment more easy and intuitive with high precision.

  6. Ultra high-speed (508 MHz) beam position digital feedback system

    International Nuclear Information System (INIS)

    Kurokawa, Shin-ichi; Kametani, Masatsugu; Nakayama, Takahide; Moriyama, Kunio.

    1997-01-01

    The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters for specific bunch in the real time operation device have become feasible. The signal transmission characteristics of this system are shown. As the result of the action test of this system, it was confirmed to work normally. (K.I.)

  7. Position automatic determination technology

    International Nuclear Information System (INIS)

    1985-10-01

    This book tells of method of position determination and characteristic, control method of position determination and point of design, point of sensor choice for position detector, position determination of digital control system, application of clutch break in high frequency position determination, automation technique of position determination, position determination by electromagnetic clutch and break, air cylinder, cam and solenoid, stop position control of automatic guide vehicle, stacker crane and automatic transfer control.

  8. Optical polarization of high-energy BL Lacertae objects

    Science.gov (United States)

    Hovatta, T.; Lindfors, E.; Blinov, D.; Pavlidou, V.; Nilsson, K.; Kiehlmann, S.; Angelakis, E.; Fallah Ramazani, V.; Liodakis, I.; Myserlis, I.; Panopoulou, G. V.; Pursimo, T.

    2016-12-01

    Context. We investigate the optical polarization properties of high-energy BL Lac objects using data from the RoboPol blazar monitoring program and the Nordic Optical Telescope. Aims: We wish to understand if there are differences between the BL Lac objects that have been detected with the current-generation TeV instruments and those objects that have not yet been detected. Methods: We used a maximum-likelihood method to investigate the optical polarization fraction and its variability in these sources. In order to study the polarization position angle variability, we calculated the time derivative of the electric vector position angle (EVPA) change. We also studied the spread in the Stokes Q/I-U/I plane and rotations in the polarization plane. Results: The mean polarization fraction of the TeV-detected BL Lacs is 5%, while the non-TeV sources show a higher mean polarization fraction of 7%. This difference in polarization fraction disappears when the dilution by the unpolarized light of the host galaxy is accounted for. The TeV sources show somewhat lower fractional polarization variability amplitudes than the non-TeV sources. Also the fraction of sources with a smaller spread in the Q/I-U/I plane and a clumped distribution of points away from the origin, possibly indicating a preferred polarization angle, is larger in the TeV than in the non-TeV sources. These differences between TeV and non-TeV samples seem to arise from differences between intermediate and high spectral peaking sources instead of the TeV detection. When the EVPA variations are studied, the rate of EVPA change is similar in both samples. We detect significant EVPA rotations in both TeV and non-TeV sources, showing that rotations can occur in high spectral peaking BL Lac objects when the monitoring cadence is dense enough. Our simulations show that we cannot exclude a random walk origin for these rotations. Conclusions: These results indicate that there are no intrinsic differences in the

  9. Square-Wave Voltage Injection Algorithm for PMSM Position Sensorless Control With High Robustness to Voltage Errors

    DEFF Research Database (Denmark)

    Ni, Ronggang; Xu, Dianguo; Blaabjerg, Frede

    2017-01-01

    relationship with the magnetic field distortion. Position estimation errors caused by higher order harmonic inductances and voltage harmonics generated by the SVPWM are also discussed. Both simulations and experiments are carried out based on a commercial PMSM to verify the superiority of the proposed method......Rotor position estimated with high-frequency (HF) voltage injection methods can be distorted by voltage errors due to inverter nonlinearities, motor resistance, and rotational voltage drops, etc. This paper proposes an improved HF square-wave voltage injection algorithm, which is robust to voltage...... errors without any compensations meanwhile has less fluctuation in the position estimation error. The average position estimation error is investigated based on the analysis of phase harmonic inductances, and deduced in the form of the phase shift of the second-order harmonic inductances to derive its...

  10. Application of high-brightness LEDs in aircraft position lights

    Science.gov (United States)

    Machi, Nicolo; Mangum, Scott; Singer, Jeffrey M.

    2004-10-01

    Solid state lighting devices have made their way into a number of niche markets and continue to make inroads into other markets as their price / performance ratios improve. One of these markets is aviation lighting. Although this paper will focus on the use of LEDs for aircraft position lights, much of the discussion is applicable to other installations on the interior and exterior of the aircraft. The color, light distribution and intensity levels for a position light are all closely regulated through Code of Federal Regulation (CFR; formerly Federal Aviation Regulation (FAR)) documents. These lighting requirements, along with harsh thermal and environmental requirements, drive the design. In this paper, we will look at these requirements and discuss what is required in order to use LEDs for this type of application. We will explore the optical, thermal and electrical issues associated with the use of LEDs for position lights and examine the specific case study of the Astreon forward position lights. Finally, we will discuss some of the challenges that we see with solid state lighting in current and future aircraft applications.

  11. [Renal biopsy in the lateral position in high risk patients: an opportunity to take advantage of].

    Science.gov (United States)

    Dugo, Mauro; Brisotto, Elisa; Vitturi, Nicola; Pasi, Alessandra; Mastrosimone, Stefania; Farneti, Fabrizio; Mangino, Margherita; Virgilio, Bice; Brunello, Anna; Pastori, Giordano; Mazzoli, Matteo; Laurino, Licia; Cova, Giandavide; Beniamin, Francesco; Maresca, Maria Cristina

    2015-01-01

    Percutaneous ultrasound-guided renal biopsy (RB) is the gold standard for diagnosis of renal diseases. The standard procedure involves biopsy in the prone position (PP) for the native kidneys. In high risk patients, transjugular and laparoscopic RB have been proposed. In patients suffering from obesity or respiratory diseases, the RB of the native kidney in the supine anterolateral position (SALP) represents an alternative to these invasive and expensive methods. We illustrate the technique of execution of RB in the lateral position (LP) on native kidneys. The procedure is safe, effective and has reduced the path travelled by the needle biopsy compared with PP and SALP.

  12. Diode-laser-pumped high efficiency continuous-wave operation at 912 nm laser in Nd:GdVO4 crystal

    International Nuclear Information System (INIS)

    Yu, X; Chen, F; Gao, J; Li, X D; Yan, R P; Zhang, K; Yu, J H; Zhang, Z H

    2009-01-01

    High efficiency operation on continuous-wave (cw) 912 nm laser at room temperature in Nd:GdVO 4 crystal pumped by 808 nm diode-laser is reported in this letter. The maximum output power of 8.0 W was obtained at the incident un-polarized pump power of 47.0 W, giving the corresponding optical-to-optical conversion efficiency of 17.0% and the average slope efficiency of 22.9%. Further tests show that the lasing threshold is reduced and the efficiency is increased evidently when using the π-polarized 808 nm pump source. 4.8 W 912 nm laser was achieved at the polarized pump power of 21.8 W, optical-to-optical conversion efficiency is increased to 22.0% and average slope efficiency is up to 33.6%

  13. Position detector

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi.

    1985-01-01

    Purpose: To enable to detect the position of an moving object in a control rod position detector, stably in a digital manner at a high accuracy and free from the undesired effects of circumstantial conditions such as the reactor temperature. Constitution: Coils connected in parallel with each other are disposed along the passage of a moving object and variable resistors and relays are connected in series with each of the coils respectively. Light emitting diodes is connected in series with the contacts of the respective relays. The resistance value of the variable resistors are adjusted depending on the changes in the circumstantial conditions and temperature distribution upon carrying out the positional detection. When the object is inserted into a coils, the relevant relay is deenergized, by which the relay contacts are closed to light up the diode. In the same manner, as the object is successively inserted into the coils, the diodes are lighted-up successively thereby enabling highly accurate and stable positional detection in a digital manner, free from the undesired effects of the circumstantial conditions. (Horiuchi, T.)

  14. A high-order positivity-preserving single-stage single-step method for the ideal magnetohydrodynamic equations

    Science.gov (United States)

    Christlieb, Andrew J.; Feng, Xiao; Seal, David C.; Tang, Qi

    2016-07-01

    We propose a high-order finite difference weighted ENO (WENO) method for the ideal magnetohydrodynamics (MHD) equations. The proposed method is single-stage (i.e., it has no internal stages to store), single-step (i.e., it has no time history that needs to be stored), maintains a discrete divergence-free condition on the magnetic field, and has the capacity to preserve the positivity of the density and pressure. To accomplish this, we use a Taylor discretization of the Picard integral formulation (PIF) of the finite difference WENO method proposed in Christlieb et al. (2015) [23], where the focus is on a high-order discretization of the fluxes (as opposed to the conserved variables). We use the version where fluxes are expanded to third-order accuracy in time, and for the fluid variables space is discretized using the classical fifth-order finite difference WENO discretization. We use constrained transport in order to obtain divergence-free magnetic fields, which means that we simultaneously evolve the magnetohydrodynamic (that has an evolution equation for the magnetic field) and magnetic potential equations alongside each other, and set the magnetic field to be the (discrete) curl of the magnetic potential after each time step. In this work, we compute these derivatives to fourth-order accuracy. In order to retain a single-stage, single-step method, we develop a novel Lax-Wendroff discretization for the evolution of the magnetic potential, where we start with technology used for Hamilton-Jacobi equations in order to construct a non-oscillatory magnetic field. The end result is an algorithm that is similar to our previous work Christlieb et al. (2014) [8], but this time the time stepping is replaced through a Taylor method with the addition of a positivity-preserving limiter. Finally, positivity preservation is realized by introducing a parameterized flux limiter that considers a linear combination of high and low-order numerical fluxes. The choice of the free

  15. A double-reprocessing high-level disinfection protocol does not eliminate positive cultures from the elevators of duodenoscopes.

    Science.gov (United States)

    Rex, Douglas K; Sieber, Marnie; Lehman, Glen A; Webb, Douglas; Schmitt, Bryan; Kressel, Amy Beth; Bang, Ji Young; Easler, Jeffery; McHenry, Lee; El-Hajj, Ihab; Fogel, Evan; Watkins, James; Sherman, Stuart

    2017-12-13

    Background and study aim  Duodenoscopes have been the source of serious infection, despite correct performance of high-level disinfection (HLD). This study aimed to observe the impact of performing HLD twice on the rate of positive cultures from duodenoscope elevators. Methods  We performed double HLD (DHLD; i. e. complete manual cleaning followed by automated reprocessing, with the entire process repeated) and then randomly cultured the elevators of our duodenoscopes on about 30 % of occasions. Results  DHLD was associated with positive elevator cultures for any microorganism in 9.4 % of cases, with a 0.8 % rate of known pathogens (627 cultures) between May 2015 and February 2016. After February 2016, and in association with changing the precleaning fluid, as well as use of a new FDA-recommended cleaning brush, the rate of positive cultures for any microorganism after DHLD was 4.8 % and 0.2 % for known pathogens (420 cultures). In a third phase, characterized by a change in personnel performing DHLD and retirement of a duodenoscope with a high rate of positive cultures, the rate of positive cultures for any microorganism was 4.9 % (783 cultures) and the rate of positive culture for known pathogens was 0.3 %. To our knowledge, no duodenoscope transmission of infection occurred during the study interval. Conclusions  DHLD resulted in a low rate of positive cultures for known pathogens and for organisms of low pathogenic potential, but did not eliminate these, from duodenoscope elevators. Additional improvements in HLD protocols and/or duodenoscope design are needed. © Georg Thieme Verlag KG Stuttgart · New York.

  16. A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization.

    Science.gov (United States)

    Zhao, Yinzhi; Zhang, Peng; Guo, Jiming; Li, Xin; Wang, Jinling; Yang, Fei; Wang, Xinzhe

    2018-06-20

    Due to the great influence of multipath effect, noise, clock and error on pseudorange, the carrier phase double difference equation is widely used in high-precision indoor pseudolite positioning. The initial position is determined mostly by the known point initialization (KPI) method, and then the ambiguities can be fixed with the LAMBDA method. In this paper, a new method without using the KPI to achieve high-precision indoor pseudolite positioning is proposed. The initial coordinates can be quickly obtained to meet the accuracy requirement of the indoor LAMBDA method. The detailed processes of the method follows: Aiming at the low-cost single-frequency pseudolite system, the static differential pseudolite system (DPL) method is used to obtain the low-accuracy positioning coordinates of the rover station quickly. Then, the ambiguity function method (AFM) is used to search for the coordinates in the corresponding epoch. The real coordinates obtained by AFM can meet the initial accuracy requirement of the LAMBDA method, so that the double difference carrier phase ambiguities can be correctly fixed. Following the above steps, high-precision indoor pseudolite positioning can be realized. Several experiments, including static and dynamic tests, are conducted to verify the feasibility of the new method. According to the results of the experiments, the initial coordinates with the accuracy of decimeter level through the DPL can be obtained. For the AFM part, both a one-meter search scope and two-centimeter or four-centimeter search steps are used to ensure the precision at the centimeter level and high search efficiency. After dealing with the problem of multiple peaks caused by the ambiguity cosine function, the coordinate information of the maximum ambiguity function value (AFV) is taken as the initial value of the LAMBDA, and the ambiguities can be fixed quickly. The new method provides accuracies at the centimeter level for dynamic experiments and at the millimeter

  17. Spin Transfer in Inclusive Λ0 Production by Transversely Polarized Protons at 200GeV/c

    International Nuclear Information System (INIS)

    Grosnick, D.P.; Hill, D.A.; Laghai, M.; Lopiano, D.; Ohashi, Y.; Spinka, H.; Stanek, R.W.; Underwood, D.G.; Yokosawa, A.; Bystricky, J.; Lehar, F.; Lesquen, A. de; Rossum, L. van; Cossairt, J.D.; Read, A.L.; Iwatani, K.; Belikov, N.I.; Derevschikov, A.A.; Grachov, O.A.; Matulenko, Y.A.; Meschanin, A.P.; Nurushev, S.B.; Patalakha, D.I.; Rykov, V.L.; Solovyanov, V.L.; Vasiliev, A.N.; Akchurin, N.; Onel, Y.; Maki, T.; Enyo, H.; Funahashi, H.; Goto, Y.; Iijima, T.; Imai, K.; Itow, Y.; Makino, S.; Masaike, A.; Miyake, K.; Nagamine, T.; Saito, N.; Yamashita, S.; Takashima, R.; Takeutchi, F.; Kuroda, K.; Michalowicz, A.; Rappazzo, G.F.; Salvato, G.; Luehring, F.C.; Miller, D.H.; Tamura, N.; Yoshida, T.; Adams, D.L.; Bonner, B.E.; Corcoran, M.D.; Cranshaw, J.; Nessi-Tedaldi, F.; Nessi, M.; Nguyen, C.; Roberts, J.B.; Skeens, J.; White, J.L.; Bravar, A.

    1997-01-01

    Surprisingly large polarizations in hyperon production by unpolarized protons have been known for a long time. The spin dynamics of the production process can be further investigated with polarized beams. Recently, a negative asymmetry A N was found in inclusive Λ 0 production with a 200GeV/c transversely polarized proton beam. The depolarization D NN in p↑+p→Λ 0 +X has been measured with the same beam over a wide x F range and at moderate p T . D NN reaches positive values of about 30% at high x F and p T ∼1.0GeV/c . This result shows a sizable spin transfer from the incident polarized proton to the outgoing Λ 0 . copyright 1997 The American Physical Society

  18. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  19. High-speed ultrafast laser machining with tertiary beam positioning (Conference Presentation)

    Science.gov (United States)

    Yang, Chuan; Zhang, Haibin

    2017-03-01

    For an industrial laser application, high process throughput and low average cost of ownership are critical to commercial success. Benefiting from high peak power, nonlinear absorption and small-achievable spot size, ultrafast lasers offer advantages of minimal heat affected zone, great taper and sidewall quality, and small via capability that exceeds the limits of their predecessors in via drilling for electronic packaging. In the past decade, ultrafast lasers have both grown in power and reduced in cost. For example, recently, disk and fiber technology have both shown stable operation in the 50W to 200W range, mostly at high repetition rate (beyond 500 kHz) that helps avoid detrimental nonlinear effects. However, to effectively and efficiently scale the throughput with the fast-growing power capability of the ultrafast lasers while keeping the beneficial laser-material interactions is very challenging, mainly because of the bottleneck imposed by the inertia-related acceleration limit and servo gain bandwidth when only stages and galvanometers are being used. On the other side, inertia-free scanning solutions like acoustic optics and electronic optical deflectors have small scan field, and therefore not suitable for large-panel processing. Our recent system developments combine stages, galvanometers, and AODs into a coordinated tertiary architecture for high bandwidth and meanwhile large field beam positioning. Synchronized three-level movements allow extremely fast local speed and continuous motion over the whole stage travel range. We present the via drilling results from such ultrafast system with up to 3MHz pulse to pulse random access, enabling high quality low cost ultrafast machining with emerging high average power laser sources.

  20. ECL-IAA and ECL-GADA Can Identify High-Risk Single Autoantibody-Positive Relatives in the TrialNet Pathway to Prevention Study.

    Science.gov (United States)

    Steck, Andrea K; Fouts, Alexandra; Miao, Dongmei; Zhao, Zhiyuan; Dong, Fran; Sosenko, Jay; Gottlieb, Peter; Rewers, Marian J; Yu, Liping

    2016-07-01

    Relatives with single positive islet autoantibodies have a much lower risk of progression to diabetes than those with multiple autoantibodies. TrialNet subjects positive for single autoantibody to insulin (mIAA) (n = 50) or single autoantibody to glutamic acid decarboxylase (GADA) (n = 50) were analyzed using new electrochemiluminescence (ECL) assays (ECL-IAA and ECL-GADA, respectively) at their initial visit and longitudinally over time. Affinity assays were performed on a subset of single autoantibody-positive subjects at initial and most recent visits. After a mean follow-up of 5.3 years, 20 subjects developed type 1 diabetes. Among either single GADA or single mIAA subjects, those who were positive in the ECL assay showed higher affinity at the initial visit, and affinity results stayed consistent over time. No converting events from low to high or high to low affinity were seen over time. Confirmed positivity for ECL is associated with high affinity and can help staging of risk for type 1 diabetes in single autoantibody-positive subjects.

  1. Output pulse-shapes of position-sensitive proportional counters using high resistance single wire

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Nishiyama, Fumitaka; Hasai, Hiromi

    1980-01-01

    The measurements and model analysis of the output pulse-shapes from a single wire proportional counter (SWPC) which has a high resistance anode are described. The characteristics of the observed pulse-shapes are determined by only one parameter which is a function of anode resistance and load resistance and they are reproduced by a simple model. Using this model, the methods for position read-out are discussed in a systematical way. (author)

  2. Effects of angling and manual handling on pike behaviour investigated by high-resolution positional telemetry

    DEFF Research Database (Denmark)

    Baktoft, Henrik; Aarestrup, Kim; Berg, Søren

    2013-01-01

    Human disturbances such as angling and manual handling may have long-term effects on the behaviour of pike, Esox lucius L., an ecologically important species. Using continuous high-resolution positional telemetry, this study compared the swimming activity of handled and unhandled pike in a small...

  3. Ocean color remote sensing using polarization properties of reflected sunlight

    Science.gov (United States)

    Frouin, R.; Pouliquen, E.; Breon, F.-M.

    1994-01-01

    The effects of the atmosphere and surface on sunlight backscattered to space by the ocean may be substantially reduced by using the unpolarized component of reflectance instead of total reflectance. At 450 nm, a wavelength of interest in ocean color remote sensing, and for typical conditions, 45% of the unpolarized reflectance may originate from the water body instead of 20% of the total reflectance, which represents a gain of a factor 2.2 in useful signal for water composition retrieval. The best viewing geometries are adjacent to the glitter region; they correspond to scattering angles around 100 deg, but they may change slightly depending on the polarization characteristics of the aerosols. As aerosol optical thickness increases, the atmosphere becomes less efficient at polarizing sunlight, and the enhancement of the water body contribution to unpolarized reflectance is reduced. Since the perturbing effects are smaller on unpolarized reflectance, at least for some viewing geometries, they may be more easily corrected, leading to a more accurate water-leaving signal and, therefore, more accurate estimates of phytoplankton pigment concentration.

  4. The effect of low versus high approach-motivated positive affect on memory for peripherally versus centrally presented information.

    Science.gov (United States)

    Gable, Philip A; Harmon-Jones, Eddie

    2010-08-01

    Emotions influence attention and processes involved in memory. Although some research has suggested that positive affect categorically influences these processes differently than neutral affect, recent research suggests that motivational intensity of positive affective states influences these processes. The present experiments examined memory for centrally or peripherally presented information after the evocation of approach-motivated positive affect. Experiment 1 found that, relative to neutral conditions, pregoal, approach-motivated positive affect (caused by a monetary incentives task) enhanced memory for centrally presented information, whereas postgoal, low approach-motivated positive affect enhanced memory for peripherally presented information. Experiment 2 found that, relative to a neutral condition, high approach-motivated positive affect (caused by appetitive pictures) enhanced memory for centrally presented information but hindered memory for peripheral information. These results suggest a more complex relationship between positive affect and memory processes and highlight the importance of considering the motivational intensity of positive affects in cognitive processes. Copyright 2010 APA

  5. Contact high: Mania proneness and positive perception of emotional touches.

    Science.gov (United States)

    Piff, Paul K; Purcell, Amanda; Gruber, June; Hertenstein, Matthew J; Keltner, Dacher

    2012-01-01

    How do extreme degrees of positive emotion-such as those characteristic of mania-influence emotion perception? The present study investigated how mania proneness, assessed using the Hypomanic Personality Scale, influences the perception of emotion via touch. Using a validated dyadic interaction paradigm for communicating emotion through touch (Hertenstein, Keltner, App, Bulleit, & Jaskolka, 2006), participants (N=53) received eight different touches to their forearm from a stranger and then identified the emotion via forced-choice methodology. Mania proneness predicted increased overall accuracy in touch perception, particularly for positive emotion touches, as well as the over-attribution of positive and under-attribution of negative emotions across all touches. These findings highlight the effects of positive emotion extremes on the perception of emotion in social interactions.

  6. Developmental Trajectories of Positive and Negative Affect in Children at High and Low Familial Risk for Depressive Disorder

    Science.gov (United States)

    Olino, Thomas M.; Lopez-Duran, Nestor L.; Kovacs, Maria; George, Charles J.; Gentzler, Amy L.; Shaw, Daniel S.

    2011-01-01

    Background: Although low positive affect (PA) and high negative affect (NA) have been posited to predispose to depressive disorders, little is known about the developmental trajectories of these affects in children at familial risk for mood disorders. Methods: We examined 202 offspring of mothers who had a history of juvenile-onset unipolar…

  7. Maximum likelihood positioning algorithm for high-resolution PET scanners

    International Nuclear Information System (INIS)

    Gross-Weege, Nicolas; Schug, David; Hallen, Patrick; Schulz, Volkmar

    2016-01-01

    Purpose: In high-resolution positron emission tomography (PET), lightsharing elements are incorporated into typical detector stacks to read out scintillator arrays in which one scintillator element (crystal) is smaller than the size of the readout channel. In order to identify the hit crystal by means of the measured light distribution, a positioning algorithm is required. One commonly applied positioning algorithm uses the center of gravity (COG) of the measured light distribution. The COG algorithm is limited in spatial resolution by noise and intercrystal Compton scatter. The purpose of this work is to develop a positioning algorithm which overcomes this limitation. Methods: The authors present a maximum likelihood (ML) algorithm which compares a set of expected light distributions given by probability density functions (PDFs) with the measured light distribution. Instead of modeling the PDFs by using an analytical model, the PDFs of the proposed ML algorithm are generated assuming a single-gamma-interaction model from measured data. The algorithm was evaluated with a hot-rod phantom measurement acquired with the preclinical HYPERION II D PET scanner. In order to assess the performance with respect to sensitivity, energy resolution, and image quality, the ML algorithm was compared to a COG algorithm which calculates the COG from a restricted set of channels. The authors studied the energy resolution of the ML and the COG algorithm regarding incomplete light distributions (missing channel information caused by detector dead time). Furthermore, the authors investigated the effects of using a filter based on the likelihood values on sensitivity, energy resolution, and image quality. Results: A sensitivity gain of up to 19% was demonstrated in comparison to the COG algorithm for the selected operation parameters. Energy resolution and image quality were on a similar level for both algorithms. Additionally, the authors demonstrated that the performance of the ML

  8. Positive Peer Support or Negative Peer Influence? the Role of Peers among Adolescents in Recovery High Schools

    Science.gov (United States)

    Karakos, Holly L.

    2014-01-01

    Evidence from previous research suggests that peers at times exert negative influence and at other times exert positive influence on drug and alcohol use among adolescents in recovery. This study explores recovery high school staff members' perceptions of peer support among students in recovery high schools using qualitative interview data. Themes…

  9. Optimal design of the absolute positioning sensor for a high-speed maglev train and research on its fault diagnosis.

    Science.gov (United States)

    Zhang, Dapeng; Long, Zhiqiang; Xue, Song; Zhang, Junge

    2012-01-01

    This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project.

  10. Optimal Design of the Absolute Positioning Sensor for a High-Speed Maglev Train and Research on Its Fault Diagnosis

    Directory of Open Access Journals (Sweden)

    Junge Zhang

    2012-08-01

    Full Text Available This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project.

  11. Self-appraisal of hockey players of high class of different playing position

    Directory of Open Access Journals (Sweden)

    Oleksiy Mikhnov

    2014-12-01

    Full Text Available Purpose: to expose the features of display of self-appraisal for the hockey players of high class of different playing position. Material and Methods: for the exposure of level of self-appraisal for hockey players, information of sportsmen of high class, taking part in the matches of the Kontinental hockey league (KHL in a season 2013–2014 was probed sixteen hockey players, having a sporting digit MS and MSWC, took part in researches. Methods were used: pedagogical supervision, pedagogical analysis and generalization of front-rank experience, psychological testing, analysis of data of the special scientific-methodical literature, expert questioning, an analysis of data is the Internet. Results: findings allowed to set that the players of line of attack (central and extreme forward have more high level of self-appraisal for certain, than players of defence and hockey goalkeepers. This tendency is looked over both on the separate constituents of self-appraisal and on the whole on all spectrums of the studied indexes. The got results of researches rotined that the hockey players of high class had or middle or high level of self-appraisal. Among testable hockey players, players were not exposed with the low level of self-appraisal. Conclusions: the exposed distinctions in the level of self-appraisal of hockey players of high class can be used for diagnostics of playing predisposition and choice of playing line of business in a command.

  12. Breast-Conservative Surgery With Close or Positive Margins: Can the Breast Be Preserved With High-Dose-Rate Brachytherapy Boost?

    International Nuclear Information System (INIS)

    Guinot, Jose Luis; Roldan, Susana; Maronas, Maria; Tortajada, Isabel; Carrascosa, Maria; Chust, Maria Luisa; Estornell, Marian; Mengual, Jose Luis; Arribas, Leoncio

    2007-01-01

    Purpose: To evaluate the likelihood of preserving the breast in women who show close or positive margins after conservative surgery for early breast carcinoma. Methods and Materials: Since 1996, 125 women with less than 5 mm or positive margins and positive separate cavity margin sampling were entered in a prospective trial with high-dose radiotherapy. A standard dose of 50 Gy to the whole breast was followed by a high-dose-rate brachytherapy application delivering 3 fractions of 4.4 Gy in 24 hours. The median follow-up was 84 months. Results: There were only seven local recurrences, with an actuarial local control rate of 95.8% at 5 years and 91.1% at 9 years. Actuarial overall and cause-specific survival rates were 92.6% and 95% at 5 years and 86.7% and 90.4% at 9 years, respectively. Late fibrosis was the most common complication, in 30% of patients, with good or excellent cosmetic results in 77%. The final result was that 95.2% of breasts were preserved. Conclusions: Close or positive-margin breast cancer can be well managed with a high-dose boost in a wide tumor bed by means of high-dose-rate brachytherapy. This technique can avoid mastectomy or poor cosmetic resection, with minimal risk of local or general failure

  13. Large Size High Performance Transparent Amorphous Silicon Sensors for Laser Beam Position Detection and Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Calderon, A.; Martinez Rivero, C.; Matorras, F.; Rodrigo, T.; Sobron, M.; Vila, I.; Virto; Alberdi, J.; Arce, P.; Barcala, J. M.; Calvo, E.; Ferrando, A.; Josa, M. I.; Luque, J. M.; Molinero, A.; Navarrete, J.; Oller, J. C.; Kohler, C.; Lutz, B.; Schubert, M. B.

    2006-09-04

    We present the measured performance of a new generation of semitransparente amorphous silicon position detectors. They have a large sensitive area (30 x 30 mm2) and show good properties such as a high response (about 20 mA/W), an intinsic position resolution better than 3 m, a spatial point reconstruction precision better than 10 m, deflection angles smaller than 10 rad and a transmission power in the visible and NIR higher than 70%. In addition, multipoint alignment monitoring, using up to five sensors lined along a light path of about 5 meters, can be achieved with a resolution better than 20m. (Author)

  14. Large Size High Performance Transparent Amorphous Silicon Sensors for Laser Beam Position Detection and Monitoring

    International Nuclear Information System (INIS)

    Calderon, A.; Martinez Rivero, C.; Matorras, F.; Rodrigo, T.; Sobron, M.; Vila, I.; Virto; Alberdi, J.; Arce, P.; Barcala, J. M.; Calvo, E.; Ferrando, A.; Josa, M. I.; Luque, J. M.; Molinero, A.; Navarrete, J.; Oller, J. C.; Kohler, C.; Lutz, B.; Schubert, M. B.

    2006-01-01

    We present the measured performance of a new generation of semitransparente amorphous silicon position detectors. They have a large sensitive area (30 x 30 mm2) and show good properties such as a high response (about 20 mA/W), an intinsic position resolution better than 3 m, a spatial point reconstruction precision better than 10 m, deflection angles smaller than 10 rad and a transmission power in the visible and NIR higher than 70%. In addition, multipoint alignment monitoring, using up to five sensors lined along a light path of about 5 meters, can be achieved with a resolution better than 20m. (Author)

  15. Influence of a high vacuum on the precise positioning using an ultrasonic linear motor.

    Science.gov (United States)

    Kim, Wan-Soo; Lee, Dong-Jin; Lee, Sun-Kyu

    2011-01-01

    This paper presents an investigation of the ultrasonic linear motor stage for use in a high vacuum environment. The slider table is driven by the hybrid bolt-clamped Langevin-type ultrasonic linear motor, which is excited with its different modes of natural frequencies in both lateral and longitudinal directions. In general, the friction behavior in a vacuum environment becomes different from that in an environment of atmospheric pressure and this difference significantly affects the performance of the ultrasonic linear motor. In this paper, to consistently provide stable and high power of output in a high vacuum, frequency matching was conducted. Moreover, to achieve the fine control performance in the vacuum environment, a modified nominal characteristic trajectory following control method was adopted. Finally, the stage was operated under high vacuum condition, and the operating performances were investigated compared with that of a conventional PI compensator. As a result, robustness of positioning was accomplished in a high vacuum condition with nanometer-level accuracy.

  16. Influence of a high vacuum on the precise positioning using an ultrasonic linear motor

    International Nuclear Information System (INIS)

    Kim, Wan-Soo; Lee, Dong-Jin; Lee, Sun-Kyu

    2011-01-01

    This paper presents an investigation of the ultrasonic linear motor stage for use in a high vacuum environment. The slider table is driven by the hybrid bolt-clamped Langevin-type ultrasonic linear motor, which is excited with its different modes of natural frequencies in both lateral and longitudinal directions. In general, the friction behavior in a vacuum environment becomes different from that in an environment of atmospheric pressure and this difference significantly affects the performance of the ultrasonic linear motor. In this paper, to consistently provide stable and high power of output in a high vacuum, frequency matching was conducted. Moreover, to achieve the fine control performance in the vacuum environment, a modified nominal characteristic trajectory following control method was adopted. Finally, the stage was operated under high vacuum condition, and the operating performances were investigated compared with that of a conventional PI compensator. As a result, robustness of positioning was accomplished in a high vacuum condition with nanometer-level accuracy.

  17. A Precision-Positioning Method for a High-Acceleration Low-Load Mechanism Based on Optimal Spatial and Temporal Distribution of Inertial Energy

    Directory of Open Access Journals (Sweden)

    Xin Chen

    2015-09-01

    Full Text Available High-speed and precision positioning are fundamental requirements for high-acceleration low-load mechanisms in integrated circuit (IC packaging equipment. In this paper, we derive the transient nonlinear dynamicresponse equations of high-acceleration mechanisms, which reveal that stiffness, frequency, damping, and driving frequency are the primary factors. Therefore, we propose a new structural optimization and velocity-planning method for the precision positioning of a high-acceleration mechanism based on optimal spatial and temporal distribution of inertial energy. For structural optimization, we first reviewed the commonly flexible multibody dynamic optimization using equivalent static loads method (ESLM, and then we selected the modified ESLM for optimal spatial distribution of inertial energy; hence, not only the stiffness but also the inertia and frequency of the real modal shapes are considered. For velocity planning, we developed a new velocity-planning method based on nonlinear dynamic-response optimization with varying motion conditions. Our method was verified on a high-acceleration die bonder. The amplitude of residual vibration could be decreased by more than 20% via structural optimization and the positioning time could be reduced by more than 40% via asymmetric variable velocity planning. This method provides an effective theoretical support for the precision positioning of high-acceleration low-load mechanisms.

  18. Anthropometric and Athletic Performance Combine Test Results Among Positions Within Grade Levels of High School-Aged American Football Players.

    Science.gov (United States)

    Leutzinger, Todd J; Gillen, Zachary M; Miramonti, Amelia M; McKay, Brianna D; Mendez, Alegra I; Cramer, Joel T

    2018-05-01

    Leutzinger, TJ, Gillen, ZM, Miramonti, AM, McKay, BD, Mendez, AI, and Cramer, JT. Anthropometric and athletic performance combine test results among positions within grade levels of high school-aged American football players. J Strength Cond Res 32(5): 1288-1296, 2018-The purpose of this study was to investigate differences among player positions at 3 grade levels in elite, collegiate-prospective American football players. Participants' data (n = 7,160) were analyzed for this study (mean height [Ht] ± SD = 178 ± 7 cm, mass [Bm] = 86 ± 19 kg). Data were obtained from 12 different high school American football recruiting combines hosted by Zybek Sports (Boulder, Colorado). Eight 2-way (9 × 3) mixed factorial analysis of variances {position (defensive back [DB], defensive end, defensive lineman, linebacker, offensive lineman [OL], quarterback, running back, tight end, and wide receiver [WR]) × grade (freshmen, sophomores, and juniors)} were used to test for differences among the mean test scores for each combine measure (Ht, Bm, 40-yard [40 yd] dash, proagility [PA] drill, L-cone [LC] drill, vertical jump [VJ], and broad jump [BJ]). There were position-related differences (p ≤ 0.05) for Ht, 40 yd dash, and BJ, within each grade level and for Bm, PA, LC, and VJ independent of grade level. Generally, the results showed that OL were the tallest, weighed the most, and exhibited the lowest performance scores among positions. Running backs were the shortest, whereas DBs and WRs weighed the least and exhibited the highest performance scores among positions. These results demonstrate the value of classifying high school-aged American football players according to their specific position rather than categorical groupings such as "line" vs. "skill" vs. "big skill" when evaluating anthropometric and athletic performance combine test results.

  19. Antiferromagnetic ordering in superconducting YBa2Cu3O6.5

    DEFF Research Database (Denmark)

    Sidis, Y.; Ulrich, C.; Bourges, P.

    2001-01-01

    Commensurate antiferromagnetic ordering has been observed in the superconducting high-T-c. cuprate YBa2Cu3O6.5 (T-c = 55 K) by polarized and unpolarized elastic neutron scattering. The magnetic peak intensity exhibits a marked enhancement at T-c. Zero-field muon-spin-resonance experiments...

  20. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial

    NARCIS (Netherlands)

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S.; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N. T.; Schultz, Marcus J.; Pelosi, Paolo; Kaczka, David W.; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications

  1. Angle resolved mass spectrometry of positive ions transmitted through high aspect ratio channels in a radio frequency discharge

    NARCIS (Netherlands)

    Stoffels - Adamowicz, E.; Stoffels, W.W.; Tachibana, K.; Imai, S.

    1997-01-01

    The behavior of positive ions in high aspect ratio structures, relevant to the reactive ion etching of deep trenches, has been studied by means of energy resolved mass spectrometry. High aspect ratio trenches are simulated by capillary plates with various aspect ratios. Angle resolved measurements

  2. Frequent EGFR Positivity and Overexpression in High-Grade Areas of Human MPNSTs

    Directory of Open Access Journals (Sweden)

    Séverine Tabone-Eglinger

    2008-01-01

    Full Text Available Malignant peripheral nerve sheath tumours (MPNSTs are highly malignant and resistant. Transformation might implicate up regulation of epidermal growth factor receptor (EGFR. Fifty-two MPNST samples were studied for EGFR, Ki-67, p53, and survivin expression by immunohistochemistry and for EGFR amplification by in situ hybridization. Results were correlated with clinical data. EGFR RNA was also quantified by RT-PCR in 20 other MPNSTs and 14 dermal neurofibromas. Half of the patients had a neurofibromatosis type 1 (NF1. EGFR expression, detected in 86% of MPNSTs, was more frequent in NF1 specimens and closely associated with high-grade and p53-positive areas. MPNSTs expressed more EGFR transcripts than neurofibromas. No amplification of EGFR locus was observed. NF1 status was the only prognostic factor in multivariate analysis, with median survivals of 18 and 43 months for patients with or without NF1. Finally, EGFR might become a new target for MPNSTs treatment, especially in NF1-associated MPNSTs.

  3. High resolution multiple sampling ionization chamber (MUSIC) sensitive to position coordinates

    International Nuclear Information System (INIS)

    Petrascu, H.; Kumagai, H.; Tanihata, I.; Petrascu, M.

    1999-01-01

    A new type of MUSIC sensitive to position coordinates is reported. The development of the first version of this type of chamber is based on the principles presented by Badhwar in 1973. The present detector will be used in experiments on fusion by using radioactive beams. This chamber due to the high resolution is suitable to identification and tracking of low Z particles. One of our goals, when we started this work, was to reduce as much as possible the Z value of particles that can be 'seen' by an ionization chamber. The resolution of the chamber was significantly improved by connecting the preamplifiers directly to the MUSIC's pads. These preamplifiers are able to work in vacuum and very low gas pressure. In this way the value of signal to noise ratio was increased by a factor of ∼10. The detector is of Frisch grid type, with the anode split into 10 active pads. It is the first model of a MUSIC with the field shared between the position grid and the anode pads. The Frisch grid was necessary because the detector is originally designed for very accurate energy measurements and particle identification. A drawing of this detector is shown. The detector itself consists of four main parts. The first one is the constant field-gradient cage, sandwiched in between the cathode and the Frisch grid. The second is the Frisch grid. The third is the position grid located under the Frisch grid. The last one is the plate with the anode pads. The cage is made of 100 μm Cu-Be wires. Every wire was tensioned with a weight representing half of its breaking limit. The Frisch grid was done on an aluminium frame, on which 20 μm W wires spaced 0.3 mm, were wound. For the position grid, 10 groups of 20 μm gold plated W wires have been used. Each group consisted of 5 wires spaced 0.9 mm and connected in parallel. The anode pads 7.8 x 60 mm 2 were perpendicular to the beam direction. Each pad and each of the position wire groups were connected to a preamplifier. The energy resolution

  4. How Young Children Learn To Read in High/Scope Programs: A Series of Position Papers.

    Science.gov (United States)

    High/Scope Educational Research Foundation, Ypsilanti, MI.

    Current debates regarding teaching children to read are centered around the most effective way to establish a foundation for literacy in the early years. This document is comprised of a set of three position papers on how the High/Scope Educational Research Foundation teaches young children to read in its infant-toddler, preschool, and early…

  5. The EDDA experiment at COSY

    Science.gov (United States)

    Rohdjess, H.

    1998-01-01

    Polarized and unpolarized proton-proton elastic scattering is investigated with the EDDA-experiment at the Cooler Synchrotron COSY at Jülich to significantly improve the world data base in the beam energy range 500-2500 MeV. Measurements during beam acceleration with thin internal targets and a large acceptance detector produce excitation functions over a broad angular and energy range with unprecedented internal consistency. Data taking with an unpolarized CH2 fiber target and an unpolarized beam have been completed and the derived differential cross sections demonstrate the benefit of this technique. With a polarized atomic beam target recently installed in COSY and a polarized COSY beam—currently under development—the measurements will be extended to analyzing powers and spin correlation parameters.

  6. The EDDA experiment at COSY

    International Nuclear Information System (INIS)

    Rohdjess, H.

    1998-01-01

    Polarized and unpolarized proton-proton elastic scattering is investigated with the EDDA-experiment at the Cooler Synchrotron COSY at Juelich to significantly improve the world data base in the beam energy range 500-2500 MeV. Measurements during beam acceleration with thin internal targets and a large acceptance detector produce excitation functions over a broad angular and energy range with unprecedented internal consistency. Data taking with an unpolarized CH 2 fiber target and an unpolarized beam have been completed and the derived differential cross sections demonstrate the benefit of this technique. With a polarized atomic beam target recently installed in COSY and a polarized COSY beam--currently under development--the measurements will be extended to analyzing powers and spin correlation parameters

  7. High prevalence of oral colonization by Candida dubliniensis in HIV-positive patients in Argentina.

    Science.gov (United States)

    Binolfi, Andrés; Biasoli, Marisa S; Luque, Alicia G; Tosello, María E; Magaró, Hortensia M

    2005-08-01

    Candida dubliniensis is a recently described yeast species, closely related to Candida albicans. This work represents the first general survey of the carriage of C. dubliniensis in the oral cavities of HIV-positive patients in Argentina. We studied 133 strains isolated from 162 HIV-positive patients, using the following identification tests: chlamydospore production on corn meal agar with Tween 80; colony color on CHROMagar Candida media; differential growth at 45 degrees C on potato dextrose agar; D-xylose assimilation; chlamydospore formation on sunflower seed agar (SSA); carbohydrate assimilation profiles using the API 20 C Aux commercial kit and PCR using primers that hybridize to the class IV intron of the ACT1 gene. Out of the 133 strains, 21 were identified as C. dubliniensis, representing approximately 13% of the 162 patients in this study. From these data, we conclude that although the PCR assay is the most reliable method, clamydospore formation on SSA is an easier and less expensive test for the screening of C. dubliniensis in the routine laboratory. Our results show that C. dubliniensis has a high prevalence among HIV-positive patients in Argentina.

  8. Identifying Relationships between High-Risk Sexual Behaviors and Screening Positive for Chlamydia and Gonorrhea in School-Wide Screening Events

    Science.gov (United States)

    Salerno, Jennifer; Darling-Fisher, Cindy; Hawkins, Nicole M.; Fraker, Elizabeth

    2013-01-01

    Background: This article describes a school-wide sexually transmitted infection (STI) screening to identify adolescent high-risk sexual behaviors, STI history/incidence, and presence of chlamydia and gonorrhea, and examines relationships between high-risk behaviors and screening positive for chlamydia and gonorrhea in an alternative high school…

  9. Maintenance of energy expenditure on high-protein vs. high-carbohydrate diets at a constant body weight may prevent a positive energy balance.

    Science.gov (United States)

    Martens, E A; Gonnissen, H K; Gatta-Cherifi, B; Janssens, P L; Westerterp-Plantenga, M S

    2015-10-01

    Relatively high-protein diets are effective for body weight loss, and subsequent weight maintenance, yet it remains to be shown whether these diets would prevent a positive energy balance. Therefore, high-protein diet studies at a constant body weight are necessary. The objective was to determine fullness, energy expenditure, and macronutrient balances on a high-protein low-carbohydrate (HPLC) diet compared with a high-carbohydrate low-protein (HCLP) diet at a constant body weight, and to assess whether effects are transient or sustained after 12 weeks. A randomized parallel study was performed in 14 men and 18 women [mean ± SD age: 24 ± 5 y; BMI (in kg/m(2)): 22.8 ± 2.0] on diets containing 30/35/35 (HPLC) or 5/60/35 (HCLP) % of energy from protein/carbohydrate/fat. Significant interactions between dietary intervention and time on total energy expenditure (TEE) (P = 0.013), sleeping metabolic rate (SMR) (P = 0.040), and diet-induced thermogenesis (DIT) (P = 0.027) appeared from baseline to wk 12. TEE was maintained in the HPLC diet group, while it significantly decreased throughout the intervention period in the HCLP diet group (wk 1: P = 0.002; wk 12: P = 0.001). Energy balance was maintained in the HPLC diet group, and became positive in the HCLP diet group at wk 12 (P = 0.008). Protein balance varied directly according to the amount of protein in the diet, and diverged significantly between the diets (P = 0.001). Fullness ratings were significantly higher in the HPLC vs. the HCLP diet group at wk 1 (P = 0.034), but not at wk 12. Maintenance of energy expenditure on HPLC vs. HCLP diets at a constant body weight may prevent development of a positive energy balance, despite transiently higher fullness. The study was registered on clinicaltrials.gov with Identifier: NCT01551238. Copyright © 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  10. Highly preserved consensus gene modules in human papilloma virus 16 positive cervical cancer and head and neck cancers.

    Science.gov (United States)

    Zhang, Xianglan; Cha, In-Ho; Kim, Ki-Yeol

    2017-12-26

    In this study, we investigated the consensus gene modules in head and neck cancer (HNC) and cervical cancer (CC). We used a publicly available gene expression dataset, GSE6791, which included 42 HNC, 14 normal head and neck, 20 CC and 8 normal cervical tissue samples. To exclude bias because of different human papilloma virus (HPV) types, we analyzed HPV16-positive samples only. We identified 3824 genes common to HNC and CC samples. Among these, 977 genes showed high connectivity and were used to construct consensus modules. We demonstrated eight consensus gene modules for HNC and CC using the dissimilarity measure and average linkage hierarchical clustering methods. These consensus modules included genes with significant biological functions, including ATP binding and extracellular exosome. Eigengen network analysis revealed the consensus modules were highly preserved with high connectivity. These findings demonstrate that HPV16-positive head and neck and cervical cancers share highly preserved consensus gene modules with common potentially therapeutic targets.

  11. A phantom for verification of dwell position and time of a high dose rate brachytherapy source

    International Nuclear Information System (INIS)

    Madebo, M.; Kron, T.; Pillainayagam, J.; Franich, R.

    2012-01-01

    Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternating strips of lead and acrylic, was used to measure dwell positions. The outer part of the phantom features recesses containing different absorber materials (lead, aluminium, acrylic and polystyrene foam), and was used for determining reproducibility of dwell times. Dwell position errors of <1 mm were easily detectable using the phantom. The effect of bending a transfer tube was studied with this phantom and no change of clinical significance was observed when varying the curvature of the transfer tube in typical clinical scenarios. Changes of dwell time as low as 0.1 s, the minimum dwell time of the treatment unit, could be detected by choosing dwell times over the four materials that produce identical exposure at the CR detector.

  12. Improving Positioning in High-Dose Radiotherapy for Prostate Cancer: Safety and Visibility of Frequently Used Gold Fiducial Markers

    Energy Technology Data Exchange (ETDEWEB)

    Fonteyne, Valerie, E-mail: valerie.fonteyne@uzgent.be [Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium); Ost, Piet [Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium); Villeirs, Geert [Department of Radiology, Ghent University Hospital, Ghent (Belgium); Oosterlinck, Willem [Department of Urology, Ghent University Hospital, Ghent (Belgium); Impens, Aline; De Gersem, Werner; De Wagter, Carlos; De Meerleer, Gert [Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium)

    2012-05-01

    Purpose: The use of gold fiducial markers (GFMs) for prostate positioning in high-dose radiotherapy is gaining interest. The purpose of this study was to compare five GFMs regarding feasibility of ultrasound-based implantation in the prostate and intraprostatic lesion (IPL); toxicity; visibility on transabdominal ultrasound (TU) and cone-beam CT (CBCT); reliability of automatic, soft tissue, and GFM-based CBCT patient positioning by comparing manual and automatic fusion CBCT. Methods and Materials: Twenty-five patients were included. Pain and toxicity were scored after implantation and high-dose radiotherapy. Fisher exact test was used to evaluate the correlation of patients' characteristics and prostatitis. Positioning was evaluated on TU and kilovoltage CBCT images. CBCT fusion was performed automatically (Elekta XVI technology, release 3.5.1 b27, based on grey values) and manually on soft tissue and GFMs. Pearson correlation statistics and Bland-Altman evaluation were used. Five GFMs were compared. Results: Twenty percent of the patients developed prostatitis despite antibiotic prophylaxis. Cigarette smoking was significantly correlated with prostatitis. The visualization of all GFMs on TU was disappointing. Consequently we cannot recommend the use of these GFMs for TU-based prostate positioning. For all GFMs, there was only fair to poor linear correlation between automatic and manual CBCT images, indicating that even when GFMs are used, an operator evaluation is imperative. However, when GFMs were analyzed individually, a moderate to very strong correlation between automatic and manual positioning was found for larger GFMs in all directions. Conclusion: The incidence of prostatitis in our series was high. Further research is imperative to define the ideal preparation protocol preimplantation and to select patients. Automatic fusion is more reliable with larger GFMs at the cost of more scatter. The stability of all GFMs was proven.

  13. High technology revisited: definition and position

    NARCIS (Netherlands)

    Steenhuis, H.J.; de Bruijn, E.J.

    2006-01-01

    This paper proposes a new approach to defining high technology by distinguishing two different aspects. First, complexity, which is a more or less a `static' view on high technology and is applied to both the final product as well as the production process. Second, the newness, relates to a

  14. Contact wire positions and contact forces. Measurements at high-speed lines in China; Fahrdrahtlage und Kontaktkraefte. Messungen an Hochgeschwindigkeitsstrecken in China

    Energy Technology Data Exchange (ETDEWEB)

    Heland, Joerg; Rick, Frank; Sarnes, Bernhard [DB Systemtechnik GmbH, Muenchen (Germany); Puschmann, Rainer [Siemens AG, Erlangen (Germany). Infrastructure and Cities

    2012-07-15

    The reliable energy transmission from overhead contact line to pantograph of traction units without interruption decides on the successful operation of high-speed railway lines. Measurements of contact wire position and contact forces are suited to assess interaction of overhead contact line and pantograph. Chinese Railways actually implement the biggest electrification program for high-speed lines worldwide. For these projects contact wire position and contact forces are monitored by procedures developed in Germany. The experience confirms that keeping the contact wire position within the specified limits lead to a superior energy transmission up to 350 km/h. (orig.)

  15. Mixed-mode distribution systems for high average power electron cyclotron heating

    International Nuclear Information System (INIS)

    White, T.L.; Kimrey, H.D.; Bigelow, T.S.

    1984-01-01

    The ELMO Bumpy Torus-Scale (EBT-S) experiment consists of 24 simple magnetic mirrors joined end-to-end to form a torus of closed magnetic field lines. In this paper, we first describe an 80% efficient mixed-mode unpolarized heating system which couples 28-GHz microwave power to the midplane of the 24 EBT-S cavities. The system consists of two radiused bends feeding a quasi-optical mixed-mode toroidal distribution manifold. Balancing power to the 24 cavities is determined by detailed computer ray tracing. A second 28-GHz electron cyclotron heating (ECH) system using a polarized grid high field launcher is described. The launcher penetrates the fundamental ECH resonant surface without a vacuum window with no observable breakdown up to 1 kW/cm 2 (source limited) with 24 kW delivered to the plasma. This system uses the same mixed-mode output as the first system but polarizes the launched power by using a grid of WR42 apertures. The efficiency of this system is 32%, but can be improved by feeding multiple launchers from a separate distribution manifold

  16. High positive computed tomography yields in the emergency ...

    African Journals Online (AJOL)

    when the diagnosis is uncertain.[1,2] It is therefore ... Methods. This was a retrospective record review of all patients who received CT ... period. Primary outcomes were to establish CT scan usage and positive yield rates. ... scans performed in the hospital. ... considered for surgical intervention may have a negative scan and.

  17. Positive Correlation between Serum Osteocalcin and Testosterone in Male Hyperthyroidism Patients with High Bone Turnover.

    Science.gov (United States)

    Zhong, N; Xu, B; Cui, R; Xu, M; Su, J; Zhang, Z; Liu, Y; Li, L; Sheng, C; Sheng, H; Qu, S

    2016-07-01

    Animal studies suggested that there is an independent bone-osteocalcin-gonadal axis, except of the hypothalamic-pituitary-gonadal axis. Based on this hypothesis, the higher osteocalcin during the high bone turnover should be followed by higher testosterone formation. Yet such clinical evidence is limited. The patients with uncontrolled hyperthyroidism are proper model with high bone turnover. If this hypothesis is true, there should be high testosterone level in patients with uncontrolled hyperthyroidism. Therefore, Graves' disease patients were recruited to study the correlation between osteocalcin and testosterone. 50 male hyperthyroidism patients with Graves' disease and 50 health persons matched by age and gender were enrolled in our cross-section study. Serum markers for thyroid hormone, sex hormone and bone metabolic markers including free triiodothyronine (FT3), free thyroxine (FT4), thyroid-stimulating hormone (TSH), testosterone, luteinizing hormone (LH), follicle-stimulating hormone (FSH) and osteocalcin (OC), C-terminal telopeptide fragments of type I collagen (CTX) were examined. The demographic parameters such as duration of disease were also collected. All data was analyzed by SPSS 20.0. High testosterone and osteocalcin level was observed in the hyperthyroidism patients (T 36.35±10.72 nmol/l and OC 46.79±26.83 ng/ml). In simple Pearson correlation, testosterone was positively associated with OC (r=0.486, Phyperthyroidism patients, osteocalcin was positively correlated with serum testosterone, which indirectly supports the hypothesis that serum osteocalcin participates in the regulation of sex hormone. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Nano-sized structured layered positive electrode materials to enable high energy density and high rate capability lithium batteries

    Science.gov (United States)

    Deng, Haixia; Belharouak, Ilias; Amine, Khalil

    2012-10-02

    Nano-sized structured dense and spherical layered positive active materials provide high energy density and high rate capability electrodes in lithium-ion batteries. Such materials are spherical second particles made from agglomerated primary particles that are Li.sub.1+.alpha.(Ni.sub.xCo.sub.yMn.sub.z).sub.1-tM.sub.tO.sub.2-dR.sub.d- , where M is selected from can be Al, Mg, Fe, Cu, Zn, Cr, Ag, Ca, Na, K, In, Ga, Ge, V, Mo, Nb, Si, Ti, Zr, or a mixture of any two or more thereof, R is selected from F, Cl, Br, I, H, S, N, or a mixture of any two or more thereof, and 0.ltoreq..alpha..ltoreq.0.50; 0

  19. Inflammatory myofibroblastic tumor of the mesentery associated with high fever and positive Widal test

    International Nuclear Information System (INIS)

    Chouairy, Camil J.; Bechara, Elie A.; Ghabril, Ramy H.; Gebran, Sleiman J.

    2008-01-01

    Inflammatory myofibroblastic tumor (IMT) is associated in 15-30% of cases with systemic symptomatology , such as prolonged fever, weight loss, elevated erythrocyte sedimentation rate (ESR) , anemia, thrombocytosis and leukocytosis. We report the case of a 4-year-old Lebanese boy who presented with high-grade fever of long duration and a single (unpaired) positive Widal agglutination test. Blood culture was negative. A diagnosis of typhoid fever was made. An abdominal (mesenteric) IMT was incidentally discovered, 30 days after the fever had appeared. After surgery, the fever disappeared immediately, and the ESR returned. We strongly favor the possibility of a false positive Widal test, due to polyclonal increase in serum immunoglobulins, which often occurs in IMT. We also think that IMT might be a mimicker of typhoid fever, both clinically and serologically. Physicians, especially pediatricians practicing in endemic areas, should probably be aware of this mimicry. (author)

  20. Inflammatory myofibroblastic tumor of the mesentery associated with high fever and positive Widal test

    Energy Technology Data Exchange (ETDEWEB)

    Chouairy, Camil J [Dept. of Pathology, Saint George Hospital, Beirut (Lebanon); Bechara, Elie A; Ghabril, Ramy H [Dept. of Pediatrics, Saint George Hospital, Beirut (Lebanon); Gebran, Sleiman J [Dept. of Pediatric Surgery, AlHada Armed Forces Hospital, Taif (Saudi Arabia)

    2008-07-01

    Inflammatory myofibroblastic tumor (IMT) is associated in 15-30% of cases with systemic symptomatology , such as prolonged fever, weight loss, elevated erythrocyte sedimentation rate (ESR) , anemia, thrombocytosis and leukocytosis. We report the case of a 4-year-old Lebanese boy who presented with high-grade fever of long duration and a single (unpaired) positive Widal agglutination test. Blood culture was negative. A diagnosis of typhoid fever was made. An abdominal (mesenteric) IMT was incidentally discovered, 30 days after the fever had appeared. After surgery, the fever disappeared immediately, and the ESR returned. We strongly favor the possibility of a false positive Widal test, due to polyclonal increase in serum immunoglobulins, which often occurs in IMT. We also think that IMT might be a mimicker of typhoid fever, both clinically and serologically. Physicians, especially pediatricians practicing in endemic areas, should probably be aware of this mimicry. (author)

  1. Effects of High Intensity White Noise on Short-Term Memory for Position in a List and Sequence

    Science.gov (United States)

    Daee, Safar; Wilding, J. M.

    1977-01-01

    Seven experiments are described investigating the effecy of high intensity white noise during the visual presentation of words on a number of short-term memory tasks. Examines results relative to position learning and sequence learning. (Editor/RK)

  2. Measurement of unpolarized semi-inclusive pi+ electroproduction off the proton

    Energy Technology Data Exchange (ETDEWEB)

    Osipenko, Mikhail; Ripani, Marco; Ricco, Giovanni; Avagyan, Harutyun; De Vita, Raffaella; Adams, Gary; Amaryan, Moscov; Amaryan, Moskov; Ambrozewicz, Pawel; Anghinolfi, Marco; Asryan, Gegham; Audit, Gerard; Bagdasaryan, H.; Baillie, Nathan; Ball, J.P.; Ball, Jacques; Baltzell, Nathan; Barrow, Steve; Battaglieri, Marco; Bedlinskiy, Ivan; Bektasoglu, Mehmet; Bellis, Matthew; Benmouna, Nawal; Berman, Barry; Biselli, Angela; Blaszczyk, Lukasz; Bonner, Billy; Bouchigny, Sylvain; Boyarinov, Sergey; Bradford, Robert; Branford, Derek; Briscoe, Wilbert; Brooks, William; Bultmann, S.; Bueltmann, Stephen; Burkert, Volker; Butuceanu, Cornel; Calarco, John; Careccia, Sharon; Carman, Daniel; Cazes, Antoine; Ceccopieri, Federico; Chen, Shifeng; Cole, Philip; Collins, Patrick; Coltharp, Philip; Corvisiero, Pietro; Crabb, Donald; Crede, Volker; Cummings, John; Dashyan, Natalya; De Masi, Rita; De Sanctis, Enzo; Degtiarenko, Pavel; Denizli, Haluk; Dennis, Lawrence; Deur, Alexandre; Dharmawardane, Kahanawita; Dhuga, Kalvir; Dickson, Richard; Djalali, Chaden; Dodge, Gail; Donnelly, J.; Doughty, David; Drozdov, V.; Dugger, Michael; Dytman, Steven; Dzyubak, Oleksandr; Egiyan, Hovanes; Egiyan, Kim; Elfassi, Lamiaa; Elouadrhiri, Latifa; Eugenio, Paul; Fatemi, Renee; Fedotov, Gleb; Feldman, Gerald; Feuerbach, Robert; Funsten, Herbert; Garcon, Michel; Gavalian, Gagik; Gilfoyle, Gerard; Giovanetti, Kevin; Girod, Francois-Xavier; Goetz, John; Golovach, Evgeny; Gonenc, Atilla; Gordon, Christopher; Gothe, Ralf; Griffioen, Keith; Guidal, Michel; Guillo, Matthieu; Guler, Nevzat; Guo, Lei; Gyurjyan, Vardan; Hadjidakis, Cynthia; Hafidi, Kawtar; Hakobyan, Hayk; Hakobyan, Rafael; Hanretty, Charles; Hardie, John; Hassall, Neil; Heddle, David; Hersman, F.; Hicks, Kenneth; Hleiqawi, Ishaq; Holtrop, Maurik; Hyde, Charles; Ilieva, Yordanka; Ilyichev, Alexander; Ireland, David; Ishkhanov, Boris; Isupov, Evgeny; Ito, Mark; Jenkins, David; Jo, Hyon-Suk; Joo, Kyungseon; Juengst, Henry; Kalantarians, Narbe; Kellie, James; Khandaker, Mahbubul; Kim, Wooyoung; Klein, Andreas; Klein, Franz; Klimenko, Alexei; Kossov, Mikhail; Krahn, Zebulun; Kramer, Laird; Kubarovsky, Valery; Kuhn, Joachim; Kuhn, Sebastian; Kuleshov, Sergey; Lachniet, Jeff; Laget, Jean; Langheinrich, Jorn; Lawrence, David; Li, Ji; Livingston, Kenneth; Lu, Haiyun; MacCormick, Marion; Marchand, Claude; Markov, Nikolai; Mattione, Paul; McAleer, Simeon; McCracken, Michael; McKinnon, Bryan; McNabb, John; Mecking, Bernhard; Mehrabyan, Surik; Melone, Joseph; Mestayer, Mac; Meyer, Curtis; Mibe, Tsutomu; Mikhaylov, Konstantin; Minehart, Ralph; Mirazita, Marco; Miskimen, Rory; Mokeev, Viktor; Morand, Ludyvine; Moriya, Kei; Morrow, Steven; Moteabbed, Maryam; Mueller, James; Munevar Espitia, Edwin; Mutchler, Gordon; Nadel-Turonski, Pawel; Napolitano, James; Nasseripour, Rakhsha; Niccolai, Silvia; Niculescu, Gabriel; Niculescu, Maria-Ioana; Niczyporuk, Bogdan; Niroula, Megh; Niyazov, Rustam; Nozar, Mina; O' Rielly, Grant; Ostrovidov, Alexander; Park, Kijun; Pasyuk, Evgueni; Paterson, Craig; Pereira, Sergio; Philips, Sasha; Pierce, Joshua; Pivnyuk, Nikolay; Pocanic, Dinko; Pogorelko, Oleg; Polli, Ermanno; Popa, Iulian; Pozdnyakov, Sergey; Preedom, Barry; Price, John; Prok, Yelena; Protopopescu, Dan; Qin, Liming; Raue, Brian; Riccardi, Gregory; Ritchie, Barry; Rosner, Guenther; Rossi, Patrizia; Rubin, Philip; Sabatie, Franck; Salamanca, Julian; Salgado, Carlos; Santoro, Joseph; Sapunenko, Vladimir; Schumacher, Reinhard; Serov, Vladimir; Sharabian, Youri; Shvedunov, Nikolay; Skabelin, Alexander; Smith, Elton; Smith, Lee; Sober, Daniel; Sokhan, Daria; Stavinskiy, Aleksey; Stepanyan, Samuel; Stepanyan, Stepan; Stokes, Burnham; Stoler, Paul; Strakovski, Igor; Strauch, Steffen; Taiuti, Mauro; Tedeschi, David; Thoma, Ulrike; Tkabladze, Avtandil; Tkachenko, Svyatoslav; Todor, Luminita; Trentadue, L.; Tur, Clarisse; Ungaro, Maurizio; Vineyard, Michael; Vlassov, Alexander; Watts, Daniel; Weinstein, Lawrence; Weygand, Dennis; Williams,

    2008-01-01

    Semi-inclusive pi+ electroproduction on protons has been measured with the CLAS detector at Jefferson Lab. The measurement was performed on a liquid-hydrogen target using a 5.75 GeV electron beam. The complete five-fold differential cross sections were measured over a wide kinematic range in Q2, x, z, and pT and over the complete range of azimuthal angles, phi, enabling us to separate the different structure functions, H2+eps*H1, H3 and H4. Our measurements of H2 at low-x were found to be in fairly good agreement with pQCD calculations, suggesting a precocious factorization of the process. Indeed, the conventional f(x)*D(z) term can account for almost all of the observed cross section, even at small z. The measured xF-distributions are in qualitative agreement with high energy data, which suggests a surprising numerical similarity between the spectator diquark fragmentation in the present reaction and the anti-quark fragmentation measured in e+e- collisions. We have observed that the p

  3. High-precision position estimation in PET using artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Mateo, F. [Digital Systems Design Group (DSD), Instituto de las Tecnologias de la Informacion y de las Comunicaciones Avanzadas (ITACA), Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)], E-mail: fermaji@upvnet.upv.es; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Lerche, Ch.W.; Colom, R.J.; Monzo, J.M.; Sebastia, A.; Gadea, R. [Digital Systems Design Group (DSD), Instituto de las Tecnologias de la Informacion y de las Comunicaciones Avanzadas (ITACA), Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2009-06-01

    Traditionally, the most popular technique to predict the impact position of gamma photons on a PET detector has been Anger's logic. However, it introduces nonlinearities that compress the light distribution, reducing the useful field of view and the spatial resolution, especially at the edges of the scintillator crystal. In this work, we make use of neural networks to address a bias-corrected position estimation from real stimulus obtained from a 2D PET system setup. The preprocessing and data acquisition were performed by separate custom boards, especially designed for this application. The results show that neural networks yield a more uniform field of view while improving the systematic error and the spatial resolution. Therefore, they stand as a better performing and readily available alternative to classic positioning methods.

  4. High-precision position estimation in PET using artificial neural networks

    International Nuclear Information System (INIS)

    Mateo, F.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Lerche, Ch.W.; Colom, R.J.; Monzo, J.M.; Sebastia, A.; Gadea, R.

    2009-01-01

    Traditionally, the most popular technique to predict the impact position of gamma photons on a PET detector has been Anger's logic. However, it introduces nonlinearities that compress the light distribution, reducing the useful field of view and the spatial resolution, especially at the edges of the scintillator crystal. In this work, we make use of neural networks to address a bias-corrected position estimation from real stimulus obtained from a 2D PET system setup. The preprocessing and data acquisition were performed by separate custom boards, especially designed for this application. The results show that neural networks yield a more uniform field of view while improving the systematic error and the spatial resolution. Therefore, they stand as a better performing and readily available alternative to classic positioning methods.

  5. A time resolving data acquisition system for multiple high-resolution position sensitive detectors

    International Nuclear Information System (INIS)

    Dimmler, D.G.

    1988-01-01

    An advanced time resolving data collection system for use in neutron and x-ray spectrometry has been implemented and put into routine operation. The system collects data from high-resolution position-sensitive area detectors with a maximum cumulative rate of 10/sup 6/ events per second. The events are sorted, in real-time, into many time-slice arrays. A programmable timing control unit allows for a wide choice of time sequences and time-slice array sizes. The shortest dwell time on a slice may be below 1 ms and the delay to switch between slices is zero

  6. Isolation of highly active monoclonal antibodies against multiresistant gram-positive bacteria.

    Directory of Open Access Journals (Sweden)

    Friederike S Rossmann

    Full Text Available Multiresistant nosocomial pathogens often cause life-threatening infections that are sometimes untreatable with currently available antibiotics. Staphylococci and enterococci are the predominant Gram-positive species associated with hospital-acquired infections. These infections often lead to extended hospital stay and excess mortality. In this study, a panel of fully human monoclonal antibodies was isolated from a healthy individual by selection of B-cells producing antibodies with high opsonic killing against E. faecalis 12030. Variable domains (VH and VL of these immunoglobulin genes were amplified by PCR and cloned into an eukaryotic expression vector containing the constant domains of a human IgG1 molecule and the human lambda constant domain. These constructs were transfected into CHO cells and culture supernatants were collected and tested by opsonophagocytic assay against E. faecalis and S. aureus strains (including MRSA. At concentrations of 600 pg/ml, opsonic killing was between 40% and 70% against all strains tested. Monoclonal antibodies were also evaluated in a mouse sepsis model (using S. aureus LAC and E. faecium, a mouse peritonitis model (using S. aureus Newman and LAC and a rat endocarditis model (using E. faecalis 12030 and were shown to provide protection in all models at a concentration of 4 μg/kg per animal. Here we present a method to produce fully human IgG1 monoclonal antibodies that are opsonic in vitro and protective in vivo against several multiresistant Gram-positive bacteria. The monoclonal antibodies presented in this study are significantly more effective compared to another monoclonal antibody currently in clinical trials.

  7. Affective processing within 1/10th of a second: High arousal is necessary for early facilitative processing of negative but not positive words.

    Science.gov (United States)

    Hofmann, Markus J; Kuchinke, Lars; Tamm, Sascha; Võ, Melissa L-H; Jacobs, Arthur M

    2009-12-01

    Lexical decisions to high- and low-arousal negative words and to low-arousal neutral and positive words were examined in an event-related potentials (ERP) study. Reaction times to positive and high-arousal negative words were shorter than those to neutral (low-arousal) words, whereas those to low-arousal negative words were longer. A similar pattern was observed in an early time window of the ERP response: Both positive and high-arousal negative words elicited greater negative potentials in a time frame of 80 to 120 msec after stimulus onset. This result suggests that arousal has a differential impact on early lexical processing of positive and negative words. Source localization in the relevant time frame revealed that the arousal effect in negative words is likely to be localized in a left occipito-temporal region including the middle temporal and fusiform gyri. The ERP arousal effect appears to result from early lexico-semantic processing in high-arousal negative words.

  8. A Vision/Inertia Integrated Positioning Method Using Position and Orientation Matching

    Directory of Open Access Journals (Sweden)

    Xiaoyue Zhang

    2017-01-01

    Full Text Available A vision/inertia integrated positioning method using position and orientation matching which can be adopted on intelligent vehicle such as automated guided vehicle (AGV and mobile robot is proposed in this work. The method is introduced firstly. Landmarks are placed into the navigation field and camera and inertial measurement unit (IMU are installed on the vehicle. Vision processor calculates the azimuth and position information from the pictures which include artificial landmarks with the known direction and position. Inertial navigation system (INS calculates the azimuth and position of vehicle in real time and the calculated pixel position of landmark can be computed from the INS output position. Then the needed mathematical models are established and integrated navigation is implemented by Kalman filter with the observation of azimuth and the calculated pixel position of landmark. Navigation errors and IMU errors are estimated and compensated in real time so that high precision navigation results can be got. Finally, simulation and test are performed, respectively. Both simulation and test results prove that this vision/inertia integrated positioning method using position and orientation matching has feasibility and it can achieve centimeter-level autonomic continuous navigation.

  9. Probing Transverse Momentum Dependent Parton Distributions in Charmonium and Bottomonium Production

    OpenAIRE

    Mukherjee, Asmita; Rajesh, Sangem

    2015-01-01

    We propose the study of unpolarized transverse momentum dependent gluon parton distributions as well as the effect of linearly polarized gluons on transverse momentum and rapidity distributions of $J/\\psi$ and $\\Upsilon$ production within the framework of transverse momentum dependent factorization employing color evaporation model (CEM) in unpolarized proton-proton collision. We estimate the transverse momentum and rapidity distributions of $J/\\psi$ and $\\Upsilon$ at LHCb, RHIC and AFTER ene...

  10. High E6 Gene Expression Predicts for Distant Metastasis and Poor Survival in Patients With HPV-Positive Oropharyngeal Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Khwaja, Shariq S.; Baker, Callie; Haynes, Wesley; Spencer, Christopher R.; Gay, Hiram; Thorstad, Wade [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States); Adkins, Douglas R. [Division of Medical Oncology, Department of Internal Medicine, Washington University School of Medicine, St. Louis, Missouri (United States); Nussenbaum, Brian [Department of Otolaryngology – Head and Neck Surgery, Washington University School of Medicine, St. Louis, Missouri (United States); Chernock, Rebecca D. [Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, Missouri (United States); Lewis, James S. [Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee (United States); Wang, Xiaowei, E-mail: xwang@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States)

    2016-07-15

    Purpose: Patients with human papillomavirus (HPV)–positive oropharyngeal squamous cell carcinoma (OPSCC) have a favorable prognosis. As a result, de-escalation clinical trials are under way. However, approximately 10% of patients will experience distant recurrence even with standard-of-care treatment. Here, we sought to identify novel biomarkers to better risk-stratify HPV-positive patients with OPSCC. Methods and Materials: Gene expression profiling by RNA sequencing (RNA-seq) and quantitative polymerase chain reaction was performed on HPV-positive OPSCC primary tumor specimens from patients with and without distant metastasis (DM). Results: RNA-seq analysis of 39 HPV-positive OPSCC specimens revealed that patients with DM had 2-fold higher E6 gene expression levels than did patients without DM (P=.029). This observation was confirmed in a validation cohort comprising 93 patients with HPV-positive OPSCC. The mean normalized E6 expression level in the 17 recurring primary specimens was 13 ± 2 compared with 8 ± 1 in the remaining 76 nonrecurring primaries (P=.001). Receiver operating characteristic analysis established an E6 expression level of 7.3 as a cutoff for worse recurrence-free survival (RFS). Patients from this cohort with high E6 gene expression (E6-high) (n=51, 55%) had more cancer-related deaths (23% vs 2%, P<.001) and DM (26% vs 5%, P<.001) than did patients with low E6 gene expression (E6-low) (n=42, 45%). Kaplan-Meier survival analysis revealed that E6-high had worse RFS (95% vs 69%, P=.004) and cancer-specific survival (97% vs 79%, P=.007). E6-high maintained statistical significance in multivariate regression models balancing surgery, chemotherapy, nodal stage, and smoking status. Gene set enrichment analysis demonstrated that tumors with high E6 expression were associated with P53, epidermal growth factor receptor, activating transcription factor-2, and transforming growth factor-β signaling pathways. Conclusion: High E6 gene expression

  11. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network.

    Science.gov (United States)

    Qi, Jun; Liu, Guo-Ping

    2017-11-06

    This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS). The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN) node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF) module, which is only used for time synchronization between different nodes, with accuracy up to 1 μ s. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF) for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM). The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS) signal.

  12. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Jun Qi

    2017-11-01

    Full Text Available This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS. The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF module, which is only used for time synchronization between different nodes, with accuracy up to 1 μs. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM. The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS signal.

  13. Sensorless SPMSM Position Estimation Using Position Estimation Error Suppression Control and EKF in Wide Speed Range

    Directory of Open Access Journals (Sweden)

    Zhanshan Wang

    2014-01-01

    Full Text Available The control of a high performance alternative current (AC motor drive under sensorless operation needs the accurate estimation of rotor position. In this paper, one method of accurately estimating rotor position by using both motor complex number model based position estimation and position estimation error suppression proportion integral (PI controller is proposed for the sensorless control of the surface permanent magnet synchronous motor (SPMSM. In order to guarantee the accuracy of rotor position estimation in the flux-weakening region, one scheme of identifying the permanent magnet flux of SPMSM by extended Kalman filter (EKF is also proposed, which formed the effective combination method to realize the sensorless control of SPMSM with high accuracy. The simulation results demonstrated the validity and feasibility of the proposed position/speed estimation system.

  14. High But Not Low Probability of Gain Elicits a Positive Feeling Leading to the Framing Effect

    Science.gov (United States)

    Gosling, Corentin J.; Moutier, Sylvain

    2017-01-01

    Human risky decision-making is known to be highly susceptible to profit-motivated responses elicited by the way in which options are framed. In fact, studies investigating the framing effect have shown that the choice between sure and risky options depends on how these options are presented. Interestingly, the probability of gain of the risky option has been highlighted as one of the main factors causing variations in susceptibility to the framing effect. However, while it has been shown that high probabilities of gain of the risky option systematically lead to framing bias, questions remain about the influence of low probabilities of gain. Therefore, the first aim of this paper was to clarify the respective roles of high and low probabilities of gain in the framing effect. Due to the difference between studies using a within- or between-subjects design, we conducted a first study investigating the respective roles of these designs. For both designs, we showed that trials with a high probability of gain led to the framing effect whereas those with a low probability did not. Second, as emotions are known to play a key role in the framing effect, we sought to determine whether they are responsible for such a debiasing effect of the low probability of gain. Our second study thus investigated the relationship between emotion and the framing effect depending on high and low probabilities. Our results revealed that positive emotion was related to risk-seeking in the loss frame, but only for trials with a high probability of gain. Taken together, these results support the interpretation that low probabilities of gain suppress the framing effect because they prevent the positive emotion of gain anticipation. PMID:28232808

  15. High But Not Low Probability of Gain Elicits a Positive Feeling Leading to the Framing Effect.

    Science.gov (United States)

    Gosling, Corentin J; Moutier, Sylvain

    2017-01-01

    Human risky decision-making is known to be highly susceptible to profit-motivated responses elicited by the way in which options are framed. In fact, studies investigating the framing effect have shown that the choice between sure and risky options depends on how these options are presented. Interestingly, the probability of gain of the risky option has been highlighted as one of the main factors causing variations in susceptibility to the framing effect. However, while it has been shown that high probabilities of gain of the risky option systematically lead to framing bias, questions remain about the influence of low probabilities of gain. Therefore, the first aim of this paper was to clarify the respective roles of high and low probabilities of gain in the framing effect. Due to the difference between studies using a within- or between-subjects design, we conducted a first study investigating the respective roles of these designs. For both designs, we showed that trials with a high probability of gain led to the framing effect whereas those with a low probability did not. Second, as emotions are known to play a key role in the framing effect, we sought to determine whether they are responsible for such a debiasing effect of the low probability of gain. Our second study thus investigated the relationship between emotion and the framing effect depending on high and low probabilities. Our results revealed that positive emotion was related to risk-seeking in the loss frame, but only for trials with a high probability of gain. Taken together, these results support the interpretation that low probabilities of gain suppress the framing effect because they prevent the positive emotion of gain anticipation.

  16. A Study of Polarization in Hyperon Production Processes

    Energy Technology Data Exchange (ETDEWEB)

    Woods, David McDill [Minnesota U.

    1995-01-01

    The polarization of $\\Xi^-$ and $\\Omega^-$ hyperons produced from both polarized and unpolarized neutral particle beams has been studied. The unpolarized neutral beam production studies are the first measurements made using this production technique. The neutral beam consisted of neutrons, $\\Lambda^0$s, $\\Xi^0$s, $K^0$s, and photons. No polarization was observed in the sample of 1.4 x $10^7 \\Xi^-$s produced by an unpolarized neutral beam. For n-s produced by an unpolarized neutral beam, a sample of 1.7 x $10^5$ events with an average momentum of 394. GeV/c had a polarization of +0.044 $\\pm$ 0.008 and a sample of 5 x 104 events with an average momentum of 304. GeV /c had a polarization of +0.036 $\\pm$ 0.015. The polarization of 7.1 x $10^5 \\Xi^- s$ produced by a polarized neutral beam was -0.118±0.004 at an average momentum of 393. GeV/c. 1.8 x $10^4 \\Omega^- s$ produced by the polarized neutral beam had a polarization of -0.069 $\\pm$ 0.023 at an average momentum of 394. GeV /c. The measurements for production from a polarized neutral beam are in agreement with a previous measurement.

  17. A new UHV micro positioning system for high load

    Energy Technology Data Exchange (ETDEWEB)

    Colldelram, Carles, E-mail: ccolldelram@cells.es; Nicolas, Josep, E-mail: jnicolas@cells.es; Nikitina, Liudmila, E-mail: lnikitina@cells.es [ALBA Synchrotron, Carretera BP 1413, de Cerdanyola del Vallès a Sant Cugat del Vallès, Km. 3,3, 08290 Cerdanyola del Vallès, Barcelona (Spain)

    2016-07-27

    have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.

  18. A new UHV micro positioning system for high load

    International Nuclear Information System (INIS)

    Colldelram, Carles; Nicolas, Josep; Nikitina, Liudmila

    2016-01-01

    have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.

  19. Polarized antiquark flavor asymmetry DELTA anti u(x)-DELTA anti d(x) and the pion cloud

    CERN Document Server

    Fries, R J; Weiss, C

    2003-01-01

    The flavor asymmetry of the unpolarized antiquark distributions in the proton, anti u(x)- anti d(x)0. Using a simple chiral linear sigma model as an example, we demonstrate that in the meson cloud picture a large positive DELTA anti u(x)-DELTA anti d(x) can be obtained from pi-sigma interference contributions. This calls into question previous estimates based on rho-meson contributions alone, and indicates how the results of the meson cloud picture may be reconciled with those of quark-based models. (orig.)

  20. The Role of Positive Psychological Capital and the Family Function in Prediction of Happiness in high school students

    Directory of Open Access Journals (Sweden)

    F rashidi kochi

    2016-11-01

    Full Text Available The aim of this study was to determine the role of positive psychological capital and family functioning in predicting happiness among adolescence. Correlational research method was recruited to analyze the data. The sample comprised of 290 high Scholl students that selected by the convenience sampling method. In this research Snyder’s hope, Nezami and Colleagues self-efficacy, Scheier and Carver's optimism, McMaster's family functioning and Connor and Davidson's Resiliency and Oxford happiness questionnaire used to collect data. Pearson correlation and stepwise regression were used to analyze data. The finding showed that there was a significant positive relationship between family function components and positive psychological capital with happiness. The results of stepwise regression showed that roles, Resiliency, self-efficacy, optimism and emotion expression had significant and important role in predicting happiness. Totally, explained 35% of the variance happiness. In conclusion, these findings indicate the importance roles of family and positive psychological capital in adolescence's happiness.

  1. An Upper Bound on High Speed Satellite Collision Probability When Only One Object has Position Uncertainty Information

    Science.gov (United States)

    Frisbee, Joseph H., Jr.

    2015-01-01

    Upper bounds on high speed satellite collision probability, PC †, have been investigated. Previous methods assume an individual position error covariance matrix is available for each object. The two matrices being combined into a single, relative position error covariance matrix. Components of the combined error covariance are then varied to obtain a maximum PC. If error covariance information for only one of the two objects was available, either some default shape has been used or nothing could be done. An alternative is presented that uses the known covariance information along with a critical value of the missing covariance to obtain an approximate but potentially useful Pc upper bound.

  2. Development of a high average current polarized electron source with long cathode operational lifetime

    Energy Technology Data Exchange (ETDEWEB)

    C. K. Sinclair; P. A. Adderley; B. M. Dunham; J. C. Hansknecht; P. Hartmann; M. Poelker; J. S. Price; P. M. Rutt; W. J. Schneider; M. Steigerwald

    2007-02-01

    Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2?105???C/cm2 and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  3. Secretory leukocyte protease inhibitor expression and high-risk HPV infection in anal lesions of HIV positive patients

    Science.gov (United States)

    NUOVO, Gerard J.; GRINSZTEJN, Beatriz; FRIEDMAN, Ruth K.; VELOSO, Valdiléa G.; CUNHA, Cynthia B.; COUTINHO, José R.; VIANNA-ANDRADE, Cecilia; OLIVEIRA, Nathalia S.; WOODHAM, Andrew W.; DA SILVA, Diane M.; KAST, W. Martin

    2016-01-01

    Objective The aim of the current study was to evaluate secretory leukocyte protease inhibitor (SLPI) expression in anal biopsies from HIV-positive (HIV+) individuals, and compare that to anal intraepithelial neoplasia (AIN) diagnoses and human papillomavirus (HPV) status. Design This is a cross-sectional study of a cohort of 54 HIV+ (31 males and 23 females) from an AIDS clinic in Rio de Janeiro, Brazil. Methods The study material consisted of anorectal tissue biopsies obtained from HIV+ subjects, which were used to construct tissue microarray paraffin blocks for immunohistochemical analysis of SLPI expression. Biopsies were evaluated by an expert pathologist and classified as low-grade anal intraepithelial neoplasia (AIN1), high-grade anal intraepithelial neoplasia (AIN2/3), or normal squamous epithelium. Additionally, DNA from the biopsies was extracted and analyzed for the presence of low- or high-risk HPV DNA. Results Histologically normal squamous epithelium from the anorectal region showed strong positive SLPI staining in 17/20 (85%) samples. In comparison, 9/17 (53%) dysplastic squamous epithelial samples from AIN1 patients showed strong SLPI staining, and only 5/17 (29%) samples from AIN2-3 patients exhibited strong SPLI staining, which both were significantly fewer than those from normal tissue (p=0.005). Furthermore, there was a significantly higher proportion of samples in which oncogenic high-risk HPV genotypes were detected in low SLPI expressing tissues than that in tissues with high SLPI expression (p=0.040). Conclusion Taken together these results suggest that low SLPI expression is associated with high-risk HPV infections in the development of AIN. PMID:27149102

  4. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  5. Electric current arising from unpolarized polyvinyl formal

    Indian Academy of Sciences (India)

    Unknown

    An appreciable electric current is observed in a system consisting of a polyvinyl formal (PVF) film in a sandwich ... Electric current; open circuit voltage; water activated phenomenon; plasticization effect. 1. Introduction ... either the trapping parameters or the distribution of the ..... For this reason contact potential drop between.

  6. Improved Limits on Spin-Mass Interactions

    Science.gov (United States)

    Lee, Junyi; Almasi, Attaallah; Romalis, Michael

    2018-04-01

    Very light particles with C P -violating couplings to ordinary matter, such as axions or axionlike particles, can mediate long-range forces between polarized and unpolarized fermions. We describe a new experimental search for such forces between unpolarized nucleons in two 250 kg Pb weights and polarized neutrons and electrons in a 3He -K comagnetometer located about 15 cm away. We place improved constraints on the products of scalar and pseudoscalar coupling constants, gpngsNneutron laboratory limit.

  7. Comparison of Conductor-Temperature Calculations Based on Different Radial-Position-Temperature Detections for High-Voltage Power Cable

    Directory of Open Access Journals (Sweden)

    Lin Yang

    2018-01-01

    Full Text Available In this paper, the calculation of the conductor temperature is related to the temperature sensor position in high-voltage power cables and four thermal circuits—based on the temperatures of insulation shield, the center of waterproof compound, the aluminum sheath, and the jacket surface are established to calculate the conductor temperature. To examine the effectiveness of conductor temperature calculations, simulation models based on flow characteristics of the air gap between the waterproof compound and the aluminum are built up, and thermocouples are placed at the four radial positions in a 110 kV cross-linked polyethylene (XLPE insulated power cable to measure the temperatures of four positions. In measurements, six cases of current heating test under three laying environments, such as duct, water, and backfilled soil were carried out. Both errors of the conductor temperature calculation and the simulation based on the temperature of insulation shield were significantly smaller than others under all laying environments. It is the uncertainty of the thermal resistivity, together with the difference of the initial temperature of each radial position by the solar radiation, which led to the above results. The thermal capacitance of the air has little impact on errors. The thermal resistance of the air gap is the largest error source. Compromising the temperature-estimation accuracy and the insulation-damage risk, the waterproof compound is the recommended sensor position to improve the accuracy of conductor-temperature calculation. When the thermal resistances were calculated correctly, the aluminum sheath is also the recommended sensor position besides the waterproof compound.

  8. Microporous nano-MgO/diatomite ceramic membrane with high positive surface charge for tetracycline removal.

    Science.gov (United States)

    Meng, Xian; Liu, Zhimeng; Deng, Cheng; Zhu, Mengfu; Wang, Deyin; Li, Kui; Deng, Yu; Jiang, Mingming

    2016-12-15

    A novel microporous nano-MgO/diatomite ceramic membrane with high positive surface charge was prepared, including synthesis of precursor colloid, dip-coating and thermal decomposition. Combined SEM, EDS, XRD and XPS studies show the nano-MgO is irregularly distributed on the membrane surface or pore walls and forms a positively charged nano coating. And the nano-MgO coating is firmly attached to the diatomite membrane via SiO chemical bond. Thus the nano-MgO/diatomite membrane behaves strong electropositivity with the isoelectric point of 10.8. Preliminary filtration tests indicate that the as-prepared nano-MgO/diatomite membrane could remove approximately 99.7% of tetracycline in water through electrostatic adsorption effect. The desirable electrostatic property enables the nano-MgO/diatomite membrane to be a candidate for removal of organic pollutants from water. And it is convinced that there will be a great application prospect of charged ceramic membrane in water treatment field. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Self-imagery in individuals with high body dissatisfaction: the effect of positive and negative self-imagery on aspects of the self-concept.

    Science.gov (United States)

    Farrar, Stephanie; Stopa, Lusia; Turner, Hannah

    2015-03-01

    Cognitive behavioural models of eating disorders highlight low self-esteem as a maintaining factor. This study explored the impact of positive and negative self-imagery on aspects of the working self (implicit and explicit self-esteem and self-concept clarity) in individuals with high body dissatisfaction (an important aspect of eating disorders). The impact of these images on state body satisfaction and affect was also explored. A group of participants with high body dissatisfaction completed measures of explicit self-esteem, self-concept clarity, state body satisfaction and affect prior to completing a negative (n = 33) or positive (n = 33) self-imagery retrieval task. Following this they completed the baseline measures and a measure of implicit self-esteem. Holding a negative self-image in mind had a negative effect on explicit self-esteem, whilst holding a positive self-image had a beneficial effect. There were no effects of imagery on implicit self-esteem. Holding a negative image in mind led to a significant reduction in self-concept clarity; however, positive self-imagery did not affect self-concept clarity. Holding a negative self-image in mind led to a decrease in body satisfaction and state affect. The opposite was found for the positive self-imagery group. Implicit self-esteem was not measured at baseline. Imagery techniques which promote positive self-images may help improve aspects of the working self, body satisfaction and affect in individuals with high levels of body dissatisfaction. As such, these imagery techniques warrant further investigation in a clinical population. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. An ecological paradox: high species diversity and low position of the upper forest line in the Andean Depression.

    Science.gov (United States)

    Peters, Thorsten; Braeuning, Achim; Muenchow, Jannes; Richter, Michael

    2014-06-01

    Systematic investigations of the upper forest line (UFL) primarily concentrate on mid and high latitudes of the Northern Hemisphere, whereas studies of Neotropical UFLs are still fragmentary. This article outlines the extraordinary high tree diversity at the UFL within the Andean Depression and unravels the links between the comparatively low position of the local UFL, high tree-species diversity, and climate. On the basis of Gentry's rapid inventory methodology for the tropics, vegetation sampling was conducted at 12 UFL sites, and local climate (temperature, wind, precipitation, and soil moisture) was investigated at six sites. Monotypic forests dominated by Polylepis were only found at the higher located margins of the Andean Depression while the lower situated core areas were characterized by a species-rich forest, which lacked the elsewhere dominant tree-species Polylepis. In total, a remarkably high tree-species number of 255 tree species of 40 different plant families was found. Beta-diversity was also high with more than two complete species turnovers. A non-linear relationship between the floristic similarity of the investigated study sites and elevation was detected. Temperatures at the investigated study sites clearly exceeded 5.5°C, the postulated threshold value for the upper tree growth limit in the tropics. Instead, quasi-permanent trade winds, high precipitation amounts, and high soil water contents affect the local position of the UFL in a negative way. Interestingly, most of the above-mentioned factors are also contributing to the high species richness. The result is a combination of a clearly marked upper forest line depression combined with an extraordinary forest line complexity, which was an almost unknown paradox.

  11. Validation of the Factor Structure of the Positive Life Assets Scale for High School Students in Thailand

    Science.gov (United States)

    Tripathi, Suriyadeo

    2018-01-01

    The aim of the present study was to determine the factor structure of the Positive Life Assets Scale (PLAS), a new measure to identify both internal and external life assets among high school students in Thailand, and to further examine the usefulness of the PLAS for a comprehensive, developmental, and strengths-based school and community…

  12. High incidence of oxacillin-susceptible mecA-positive Staphylococcus aureus (OS-MRSA associated with bovine mastitis in China.

    Directory of Open Access Journals (Sweden)

    WanXia Pu

    Full Text Available Staphylococcus aureus is a main cause of bovine mastitis and a major pathogen affecting human health. The emergence and spread of methicillin-resistant Staphylococcus aureus (MRSA has become a significant concern for both animal health and public health. This study investigated the incidence of MRSA in milk samples collected from dairy cows with clinical mastitis and characterized the MRSA isolates using antimicrobial susceptibility tests and genetic typing methods. In total, 103 S. aureus isolates were obtained from dairy farms in 4 different provinces in China, including Gansu, Shanghai, Sichuan, and Guizhou. Antimicrobial susceptibility testing of these isolates revealed that the resistance rates to penicillin and sulfamethoxazole were high, while the resistance rates to ciprofloxacin and vancomycin were low. Among the 103 isolates, 49 (47.6% were found to be mecA-positive, indicating the high incidence of MRSA. However, 37 of the 49 mecA-positive isolates were susceptible to oxacillin as determined by antimicrobial susceptibility assays and were thus classified as oxacillin-susceptible mecA-positive S. aureus (OS-MRSA. These isolates could be misclassified as methicillin susceptible Staphylococcus aureus (MSSA if genetic detection of mecA was not performed. Molecular characterization of selected mecA-positive isolates showed that they were all negative with Panton-Valentine leukocidin (PVL, but belonged to different spa types and SCCmec types. These results indicate that OS-MRSA is common in bovine mastitis in China and underscore the need for genetic methods (in addition to phenotypic tests to accurately identify MRSA.

  13. High serum coenzyme Q10, positively correlated with age, selenium and cholesterol in Inuit of Greenland

    DEFF Research Database (Denmark)

    Pedersen, Henning Sloth; Mortensen, S.A.; Rhode, M.

    1999-01-01

    impact. From a health survey we chose the subpopulation from the most remote area, where the traditional Greenlandic diet with high intake of sea mammals and fish predominates. The mean (SD) of S-CoQ10 in males was 1.495 (0.529) nmol/ml and 1.421 (0.629) nmol/ml in females, significantly higher (p ....001) compared to a Danish population. In a linear multiple regression model the S-CoQ10 level is significantly positively associated with age and S-selenium in males, and S-total cholesterol in females. The high level of CoQ10 in Greenlanders probably reflects diet, since no bioaccumulation takes place...

  14. Non-perturbative inputs for gluon distributions in the hadrons

    International Nuclear Information System (INIS)

    Ermolaev, B.I.; Troyan, S.I.

    2017-01-01

    Description of hadronic reactions at high energies is conventionally done in the framework of QCD factorization. All factorization convolutions comprise non-perturbative inputs mimicking non-perturbative contributions and perturbative evolution of those inputs. We construct inputs for the gluon-hadron scattering amplitudes in the forward kinematics and, using the optical theorem, convert them into inputs for gluon distributions in the hadrons, embracing the cases of polarized and unpolarized hadrons. In the first place, we formulate mathematical criteria which any model for the inputs should obey and then suggest a model satisfying those criteria. This model is based on a simple reasoning: after emitting an active parton off the hadron, the remaining set of spectators becomes unstable and therefore it can be described through factors of the resonance type, so we call it the resonance model. We use it to obtain non-perturbative inputs for gluon distributions in unpolarized and polarized hadrons for all available types of QCD factorization: basic, K_T-and collinear factorizations. (orig.)

  15. Non-perturbative inputs for gluon distributions in the hadrons

    Energy Technology Data Exchange (ETDEWEB)

    Ermolaev, B.I. [Ioffe Physico-Technical Institute, Saint Petersburg (Russian Federation); Troyan, S.I. [St. Petersburg Institute of Nuclear Physics, Gatchina (Russian Federation)

    2017-03-15

    Description of hadronic reactions at high energies is conventionally done in the framework of QCD factorization. All factorization convolutions comprise non-perturbative inputs mimicking non-perturbative contributions and perturbative evolution of those inputs. We construct inputs for the gluon-hadron scattering amplitudes in the forward kinematics and, using the optical theorem, convert them into inputs for gluon distributions in the hadrons, embracing the cases of polarized and unpolarized hadrons. In the first place, we formulate mathematical criteria which any model for the inputs should obey and then suggest a model satisfying those criteria. This model is based on a simple reasoning: after emitting an active parton off the hadron, the remaining set of spectators becomes unstable and therefore it can be described through factors of the resonance type, so we call it the resonance model. We use it to obtain non-perturbative inputs for gluon distributions in unpolarized and polarized hadrons for all available types of QCD factorization: basic, K{sub T}-and collinear factorizations. (orig.)

  16. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  17. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  18. Photodiode array for position-sensitive detection using high X-ray flux provided by synchrotron radiation

    Science.gov (United States)

    Jucha, A.; Bonin, D.; Dartyge, E.; Flank, A. M.; Fontaine, A.; Raoux, D.

    1984-09-01

    Synchrotron radiation provides a high intensity source over a large range of wavelengths. This is the prominent quality that has laid the foundations of the EXAFS development (Extended X-ray Absorption Fine Structure). EXAFS data can be collected in different ways. A full scan requires 5 to 10 min, compared to the one-day data collection of a conventional Bremsstrahlung X-ray tube. Recently, by using the new photodiode array (R 1024 SFX) manufactured by Reticon, it has been possible to reduce the data collection time to less than 100 ms. The key elements of this new EXAFS method are a dispersive optics combined with a position sensitive detector able to work under very high flux conditions. The total aperture of 2500 μm × 25 μm for each pixel is well suited to spectroscopic applications. Besides its high dynamic range (> 10 4) and its linearity, the rapidity of the readout allows a flux of 10 9-10 10 photons/s over the 1024 sensing elements.

  19. Nucleon Compton Scattering with Two Space-Like Photons

    International Nuclear Information System (INIS)

    Andrei Afanasev; I. Akushevich; N.P. Merenkov

    2002-01-01

    We calculate two-photon exchange effects for elastic electron-proton scattering at high momentum transfers. The corresponding nucleon Compton amplitude is defined by two space-like virtual photons that appear to have significant virtualities. We make predictions for (a) a single-spin beam asymmetry, and (b) a single-spin target asymmetry or recoil proton polarization caused by an unpolarized electron beam

  20. STANFORD (SLAC): Precision electroweak result

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Precision testing of the electroweak sector of the Standard Model has intensified with the recent publication* of results from the SLD collaboration's 1993 run on the Stanford Linear Collider, SLC. Using a highly polarized electron beam colliding with an unpolarized positron beam, SLD physicists measured the left-right asymmetry at the Z boson resonance with dramatically improved accuracy over 1992

  1. Accuracy and repeatability positioning of high-performancel athe for non-circular turning

    Directory of Open Access Journals (Sweden)

    Majda Paweł

    2017-11-01

    Full Text Available This paper presents research on the accuracy and repeatability of CNC axis positioning in an innovative lathe with an additional Xs axis. This axis is used to perform movements synchronized with the angular position of the main drive, i.e. the spindle, and with the axial feed along the Z axis. This enables the one-pass turning of non-circular surfaces, rope and trapezoidal threads, as well as the surfaces of rotary tools such as a gear cutting hob, etc. The paper presents and discusses the interpretation of results and the calibration effects of positioning errors in the lathe’s numerical control system. Finally, it shows the geometric characteristics of the rope thread turned at various spindle speeds, including before and after-correction of the positioning error of the Xs axis.

  2. Accuracy and repeatability positioning of high-performancel athe for non-circular turning

    Science.gov (United States)

    Majda, Paweł; Powałka, Bartosz

    2017-11-01

    This paper presents research on the accuracy and repeatability of CNC axis positioning in an innovative lathe with an additional Xs axis. This axis is used to perform movements synchronized with the angular position of the main drive, i.e. the spindle, and with the axial feed along the Z axis. This enables the one-pass turning of non-circular surfaces, rope and trapezoidal threads, as well as the surfaces of rotary tools such as a gear cutting hob, etc. The paper presents and discusses the interpretation of results and the calibration effects of positioning errors in the lathe's numerical control system. Finally, it shows the geometric characteristics of the rope thread turned at various spindle speeds, including before and after-correction of the positioning error of the Xs axis.

  3. Co(OH)2/RGO/NiO sandwich-structured nanotube arrays with special surface and synergistic effects as high-performance positive electrodes for asymmetric supercapacitors

    Science.gov (United States)

    Xu, Han; Zhang, Chi; Zhou, Wen; Li, Gao-Ren

    2015-10-01

    High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (~1470 F g-1 at 5 mV s-1) and excellent cycling stability with ~98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg-1), a high power density (27.5 kW kg-1) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs.High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (~1470 F g-1 at 5 mV s-1) and excellent cycling stability with ~98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and

  4. Guided-mode resonant filters and reflectors: Principles, design, and fabrication

    Science.gov (United States)

    Niraula, Manoj

    In this dissertation, we overview the operational principles of these resonant periodic structures, discuss the methods of their design and fabrication, and propose and demonstrate novel functionalities for spatial and spectral filtering, and unpolarized wideband reflection. Fashioned with materially sparse gratings, these optical devices are easy to fabricate and integration friendly compared to their traditional multi-layer counterparts making their research and development critical for practical applications. We study, theoretically, modal properties and parametric dependence of resonant periodic bandpass filters operating in the mid- and near-infrared spectral domains. We investigate three different device architectures consisting of single, double, and triple layers based on all-transparent dielectric and semiconductor thin films. We present three modal coupling configurations forming complex mixtures of two or three distinct leaky modes coupling at different evanescent diffraction orders. Our modal analysis demonstrates key attributes of subwavelength periodic thin-film structures in multiple-modal blending to achieve desired transmission spectra. We provide the first experimental demonstration of high-efficiency and narrow-linewidth resonant bandpass filter applying a single patterned silicon layer on a quartz substrate. Its performance corresponds to bandpass filters requiring 15 traditional Si/SiO2 thin-film layers. The feasibility of sparse narrowband, high-efficiency bandpass filters with extremely wide, flat, and low sidebands is thereby demonstrated. The proposed technology is integration-friendly and opens doors for further development in various disciplines and spectral regions where thin-film solutions are traditionally applied. We demonstrate concurrent spatial and spectral filtering as a new outstanding attribute of resonant periodic devices. This functionality is enabled by a unique, near-complete, reflection state that is discrete in both

  5. Non-Imaging Speckle Interferometry forHigh Speed Nanometer-Scale Position Detection

    OpenAIRE

    van Putten, E. G.; Lagendijk, A.; Mosk, A. P.

    2011-01-01

    We experimentally demonstrate a non-imaging approach to displacement measurement for complex scattering materials. By spatially controlling the wave front of the light that incidents on the material we concentrate the scattered light in a focus on a designated position. This wave front acts as an unique optical fingerprint that enables precise position detection of the illuminated material by simply measuring the intensity in the focus. By combining two optical fingerprints we demonstrate pos...

  6. Selective anti-proliferation of HER2-positive breast cancer cells by anthocyanins identified by high-throughput screening.

    Directory of Open Access Journals (Sweden)

    Weihua Liu

    Full Text Available Overexpressed Human epidermal growth factor receptor 2 (HER2 drives the biology of 20% breast cancer and is a prediction of a poor prognosis for patients. HER2-targeted therapies significantly improve outcomes for HER2-positive patients. Traditional Chinese herbs/medicines have been used to treat breast cancer patients including HER2-positive patients in Asia for decades. Although the traditional medicines demonstrate efficacy in clinics for HER2-positive patients, the mechanism is largely unknown. In this article, we screened a 10,000 natural product library in 6 different cell lines representing breast cancer, and assessed the ability of each drug to cause cytotoxicity through a high-throughput screening approach. We have identified eight natural compounds that selectively inhibit the proliferation of HER2-positive cells. Two of the hit compounds, peonidin-3-glucoside and cyaniding-3-glucoside, are both extracts from black rice. They inhibit the phospho-HER2 and phospho-AKT and were confirmed to induce HER2-psotive breast cancer cells apoptosis both in vitro and in vivo. Peonidin-3-glucoside and cyaniding-3-glucoside treatments significantly reduced the tumor size and volume in vivo compared to the control group. There is no significant difference of antitumorgenic effects between peonidin-3-glucoside and cyaniding-3-glucoside treatments.

  7. Accuracy of Administrative Codes for Distinguishing Positive Pressure Ventilation from High-Flow Nasal Cannula.

    Science.gov (United States)

    Good, Ryan J; Leroue, Matthew K; Czaja, Angela S

    2018-06-07

    Noninvasive positive pressure ventilation (NIPPV) is increasingly used in critically ill pediatric patients, despite limited data on safety and efficacy. Administrative data may be a good resource for observational studies. Therefore, we sought to assess the performance of the International Classification of Diseases, Ninth Revision procedure code for NIPPV. Patients admitted to the PICU requiring NIPPV or heated high-flow nasal cannula (HHFNC) over the 11-month study period were identified from the Virtual PICU System database. The gold standard was manual review of the electronic health record to verify the use of NIPPV or HHFNC among the cohort. The presence or absence of a NIPPV procedure code was determined by using administrative data. Test characteristics with 95% confidence intervals (CIs) were generated, comparing administrative data with the gold standard. Among the cohort ( n = 562), the majority were younger than 5 years, and the most common primary diagnosis was bronchiolitis. Most (82%) required NIPPV, whereas 18% required only HHFNC. The NIPPV code had a sensitivity of 91.1% (95% CI: 88.2%-93.6%) and a specificity of 57.6% (95% CI: 47.2%-67.5%), with a positive likelihood ratio of 2.15 (95% CI: 1.70-2.71) and negative likelihood ratio of 0.15 (95% CI: 0.11-0.22). Among our critically ill pediatric cohort, NIPPV procedure codes had high sensitivity but only moderate specificity. On the basis of our study results, there is a risk of misclassification, specifically failure to identify children who require NIPPV, when using administrative data to study the use of NIPPV in this population. Copyright © 2018 by the American Academy of Pediatrics.

  8. Position statement: start middle and high schools at 8:30 am or later to promote student health and learning.

    Science.gov (United States)

    Trevorrow, Tracy; Zhou, Eric S; Dietch, Jessica R; Gonzalez, Brian D

    2018-03-13

    The Society of Behavioral Medicine recommends school officials start middle and high school classes at 8:30 am or later. Such a schedule promotes students' sleep health, resulting in improvements in physical health, psychological well-being, attention and concentration, academic performance, and driving safety. In this position statement, we propose a four-tiered approach to promote later school start times for middle and high schools.

  9. A Positive Deviance Approach to Early Childhood Obesity: Cross-Sectional Characterization of Positive Outliers

    OpenAIRE

    Foster, Byron Alexander; Farragher, Jill; Parker, Paige; Hale, Daniel E.

    2015-01-01

    Objective: Positive deviance methodology has been applied in the developing world to address childhood malnutrition and has potential for application to childhood obesity in the United States. We hypothesized that among children at high-risk for obesity, evaluating normal weight children will enable identification of positive outlier behaviors and practices.

  10. Take a look at the bright side: Effects of positive body exposure on selective visual attention in women with high body dissatisfaction.

    Science.gov (United States)

    Glashouwer, Klaske A; Jonker, Nienke C; Thomassen, Karen; de Jong, Peter J

    2016-08-01

    Women with high body dissatisfaction look less at their 'beautiful' body parts than their 'ugly' body parts. This study tested the robustness of this selective viewing pattern and examined the influence of positive body exposure on body-dissatisfied women's attention for 'ugly' and 'beautiful' body parts. In women with high body dissatisfaction (N = 28) and women with low body dissatisfaction (N = 14) eye-tracking was used to assess visual attention towards pictures of their own and other women's bodies. Participants with high body dissatisfaction were randomly assigned to 5 weeks positive body exposure (n = 15) or a no-treatment condition (n = 13). Attention bias was assessed again after 5 weeks. Body-dissatisfied women looked longer at 'ugly' than 'beautiful' body parts of themselves and others, while participants with low body dissatisfaction attended equally long to own/others' 'beautiful' and 'ugly' body parts. Although positive body exposure was very effective in improving participants' body satisfaction, it did not systematically change participants' viewing pattern. The tendency to preferentially allocate attention towards one's 'ugly' body parts seems a robust phenomenon in women with body dissatisfaction. Yet, modifying this selective viewing pattern seems not a prerequisite for successfully improving body satisfaction via positive body exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Local SAR in High Pass Birdcage and TEM Body Coils for Multiple Human Body Models in Clinical Landmark Positions at 3T

    Science.gov (United States)

    Yeo, Desmond TB; Wang, Zhangwei; Loew, Wolfgang; Vogel, Mika W; Hancu, Ileana

    2011-01-01

    Purpose To use EM simulations to study the effects of body type, landmark position, and RF body coil type on peak local SAR in 3T MRI. Materials and Methods Numerically computed peak local SAR for four human body models (HBMs) in three landmark positions (head, heart, pelvic) were compared for a high-pass birdcage and a transverse electromagnetic 3T body coil. Local SAR values were normalized to the IEC whole-body average SAR limit of 2.0 W/kg for normal scan mode. Results Local SAR distributions were highly variable. Consistent with previous reports, the peak local SAR values generally occurred in the neck-shoulder area, near rungs, or between tissues of greatly differing electrical properties. The HBM type significantly influenced the peak local SAR, with stockier HBMs, extending extremities towards rungs, displaying the highest SAR. There was also a trend for higher peak SAR in the head-centric and heart-centric positions. The impact of the coil-types studied was not statistically significant. Conclusion The large variability in peak local SAR indicates the need to include more than one HBM or landmark position when evaluating safety of body coils. It is recommended that a HBM with arms near the rungs be included, to create physically realizable high-SAR scenarios. PMID:21509880

  12. Endotoxin levels correlate positively with a sedentary lifestyle and negatively with highly trained subjects.

    Science.gov (United States)

    Lira, Fabio S; Rosa, Jose C; Pimentel, Gustavo D; Souza, Hélio A; Caperuto, Erico C; Carnevali, Luiz C; Seelaender, Marília; Damaso, Ana R; Oyama, Lila M; de Mello, Marco T; Santos, Ronaldo V

    2010-08-04

    A sedentary lifestyle increases the risk of developing cardiovascular disease, obesity, and diabetes. This phenomenon is supported by recent studies suggesting a chronic, low-grade inflammation status. Endotoxin derived from gut flora may be key to the development of inflammation by stimulating the secretion of inflammatory factors. This study aimed to examine plasma inflammatory markers and endotoxin levels in individuals with a sedentary lifestyle and/or in highly trained subjects at rest. Fourteen male subjects (sedentary lifestyle n = 7; highly trained subjects n = 7) were recruited. Blood samples were collected after an overnight fast (approximately 12 h). The plasmatic endotoxin, plasminogen activator inhibitor type-1 (PAI-1), monocyte chemotactic protein-1 (MCP1), ICAM/CD54, VCAM/CD106 and lipid profile levels were determined. Endotoxinemia was lower in the highly trained subject group relative to the sedentary subjects (p < 0.002). In addition, we observed a positive correlation between endotoxin and PAI-1 (r = 0.85, p < 0.0001), endotoxin and total cholesterol (r = 0.65; p < 0.01), endotoxin and LDL-c (r = 0.55; p < 0.049) and endotoxin and TG levels (r = 0.90; p < 0.0001). The plasma levels of MCP-1, ICAM/CD54 and VCAM/CD106 did not differ. These results indicate that a lifestyle associated with high-intensity and high-volume exercise induces favorable changes in chronic low-grade inflammation markers and may reduce the risk for diseases such as obesity, diabetes and cardiovascular diseases.

  13. Risk of persistent high-grade squamous intraepithelial lesion after electrosurgical excisional treatment with positive margins: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Caroline Alves de Oliveira

    Full Text Available CONTEXT AND OBJECTIVE: Even if precursor lesions of cervical cancer are properly treated, there is a risk of persistence or recurrence. The aim here was to quantify the risks of persistence of high-grade intraepithelial squamous lesions, one and two years after cervical electrosurgical excisional treatment with positive margins. DESIGN AND SETTING: Systematic review of the literature and meta-analysis at Instituto Fernandes Figueira. METHODS: This meta-analysis was on studies published between January 1989 and July 2009 that were identified in Medline, Scopus, Embase, Cochrane, SciELO, Lilacs, Adolec, Medcarib, Paho, Wholis, Popline, ISI Web of Science and Sigle. Articles were selected if they were cohort studies on electrosurgical excisional treatment of high-grade squamous intraepithelial lesions with a minimum follow-up of one year, a histopathological outcome of persistence of these lesions and a small risk of bias. RESULTS: The search identified 7,066 articles and another 21 in the reference lists of these papers. After applying the selection and exclusion criteria, only four articles were found to have extractable data. The risk of persistence of high-grade intraepithelial lesions after one year was 11.36 times greater (95% confidence interval, CI: 5.529-23.379, P < 0.0001 in patients with positive margins and after two years, was four times greater (95% CI: 0.996-16.164, although without statistical significance. CONCLUSION: This meta-analysis confirms the importance of positive margins as an indicator of incomplete treatment after the first year of follow-up and highlights the need for appropriately chosen electrosurgical techniques based on disease location and extent, with close surveillance of these patients.

  14. One lesion, one virus: individual components of high-grade anal intraepithelial neoplasia in HIV-positive men contain a single HPV type

    NARCIS (Netherlands)

    Richel, Olivier; Quint, Koen D.; Lindeman, Jan; van Noesel, Carel J. M.; de Koning, Maurits N. C.; van den Munckhof, Henk A. M.; de Vries, Henry J. C.; Prins, Jan M.; Quint, Wim G. V.

    2014-01-01

    High-grade anal intraepithelial neoplasia (AIN) is present in many human immunodeficiency virus (HIV)-positive men who have sex with men. The major etiologic factor is infection with an oncogenic human papillomavirus (HPV) genotype. We investigated whether individual components of high-grade AIN are

  15. Positive association between high-sensitivity C-reactive protein level and diabetes mellitus among US non-Hispanic black adults.

    Science.gov (United States)

    Shankar, A; Li, J

    2008-08-01

    Previous epidemiologic studies have demonstrated a positive association between serum C-reactive protein (CRP) level and diabetes mellitus. However among US race-ethnicities, the putative association between CRP and diabetes mellitus in non-Hispanic Blacks is not clear. We specifically examined the association between high-sensitivity CRP level and diabetes mellitus in a representative sample of US non-Hispanic blacks. Cross-sectional study among 1,479 National Health and Nutrition Examination Survey 1999-2002 non-Hispanic black participants aged > or = 20 years. Main outcome-of-interest was the presence of diabetes mellitus (fasting plasma glucose > or = 126 mg/dL, non-fasting plasma glucose > or = 200 mg/dL, or self-reported current use of oral hypoglycemic medication or insulin) (n=204). Higher CRP levels were positively associated with diabetes mellitus, independent of smoking, waist circumference, hypertension, and other confounders. Multivariable odds ratio (OR) [95% confidence intervals (CI)] comparing elevated CRP level (>3 mg/L) to low CRP level (diabetes mellitus appeared to be present across the full range of CRP, without any threshold effect. Higher serum high-sensitivity CRP levels are positively associated with diabetes mellitus in a sample of US non-Hispanic blacks. Inflammatory processes previously shown to be related to diabetes mellitus in other race-ethnicities may be involved in non-Hispanic blacks also.

  16. Audiological manifestations in HIV-positive adults

    Directory of Open Access Journals (Sweden)

    Carla Gentile Matas

    2014-07-01

    Full Text Available OBJECTIVE:To characterize the findings of behavioral hearing assessment in HIV-positive individuals who received and did not receive antiretroviral treatment.METHODS:This research was a cross-sectional study. The participants were 45 HIV-positive individuals (18 not exposed and 27 exposed to antiretroviral treatment and 30 control-group individuals. All subjects completed an audiological evaluation through pure-tone audiometry, speech audiometry, and high-frequency audiometry.RESULTS:The hearing thresholds obtained by pure-tone audiometry were different between groups. The group that had received antiretroviral treatment had higher thresholds for the frequencies ranging from 250 to 3000 Hz compared with the control group and the group not exposed to treatment. In the range of frequencies from 4000 through 8000 Hz, the HIV-positive groups presented with higher thresholds than did the control group. The hearing thresholds determined by high-frequency audiometry were different between groups, with higher thresholds in the HIV-positive groups.CONCLUSION:HIV-positive individuals presented poorer results in pure-tone and high-frequency audiometry, suggesting impairment of the peripheral auditory pathway. Individuals who received antiretroviral treatment presented poorer results on both tests compared with individuals not exposed to antiretroviral treatment.

  17. Audiological manifestations in HIV-positive adults.

    Science.gov (United States)

    Matas, Carla Gentile; Angrisani, Rosanna Giaffredo; Magliaro, Fernanda Cristina Leite; Segurado, Aluisio Augusto Cotrim

    2014-07-01

    To characterize the findings of behavioral hearing assessment in HIV-positive individuals who received and did not receive antiretroviral treatment. This research was a cross-sectional study. The participants were 45 HIV-positive individuals (18 not exposed and 27 exposed to antiretroviral treatment) and 30 control-group individuals. All subjects completed an audiological evaluation through pure-tone audiometry, speech audiometry, and high-frequency audiometry. The hearing thresholds obtained by pure-tone audiometry were different between groups. The group that had received antiretroviral treatment had higher thresholds for the frequencies ranging from 250 to 3000 Hz compared with the control group and the group not exposed to treatment. In the range of frequencies from 4000 through 8000 Hz, the HIV-positive groups presented with higher thresholds than did the control group. The hearing thresholds determined by high-frequency audiometry were different between groups, with higher thresholds in the HIV-positive groups. HIV-positive individuals presented poorer results in pure-tone and high-frequency audiometry, suggesting impairment of the peripheral auditory pathway. Individuals who received antiretroviral treatment presented poorer results on both tests compared with individuals not exposed to antiretroviral treatment.

  18. Streamer knotwilg branching: sudden transition in morphology of positive streamers in high-purity nitrogen

    International Nuclear Information System (INIS)

    Heijmans, L C J; Clevis, T T J; Nijdam, S; Van Veldhuizen, E M; Ebert, U

    2015-01-01

    We describe a peculiar branching phenomenon in positive repetitive streamer discharges in high purity nitrogen. We name it knotwilg branching after the Dutch word for a pollard willow tree. In a knotwilg branching a thick streamer suddenly splits into many thin streamers. Under some conditions this happens for all streamers in a discharge at about the same distance from the high-voltage electrode tip. At this distance, the thick streamers suddenly bend sharply and appear to propagate over a virtual surface surrounding the high-voltage electrode, rather than following the background electric field lines. From these bent thick streamers many, much thinner, streamers emerge that roughly follow the background electric field lines, creating the characteristic knotwilg branching. We have only found this particular morphology in high purity nitrogen at pressures in the range 50 to 200 mbar and for pulse repetition rates above 1 Hz; the experiments were performed for an electrode distance of 16 cm and for fast voltage pulses of 20 or 30 kV. These observations clearly disagree with common knowledge on streamer propagation. We have analyzed the data of several tens of thousands of discharges to clarify the phenomena. We also present some thoughts on how the ionization of the previous discharges could concentrate into some pre-ionization region near the needle electrode and create the knotwilg morphology, but we present no final explanation. (paper)

  19. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Seon Yeong; Kim, Eun-San, E-mail: eskim1@knu.ac.kr; Hwang, Ji-Gwang; Heo, A.; Won, Jang Si [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Vinokurov, Nikolay A.; Jeong, Young UK, E-mail: yujung@kaeri.re.kr; Hee Park, Seong; Jang, Kyu-Ha [WCI Center for Quantum-Beam-based Radiation Research, Korea Atomic Energy Research Institute, 989-111 Daedeok-Daero, Yuseong-gu, Daejeon (Korea, Republic of)

    2015-01-15

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  20. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    Science.gov (United States)

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A.; won Jang, Si; Vinokurov, Nikolay A.; Jeong, Young UK; Hee Park, Seong; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  1. Implementing Schoolwide Positive Behavior Support in High School Settings: Analysis of Eight High Schools

    Science.gov (United States)

    Flannery, K. Brigid; Frank, Jennifer L.; Kato, Mimi McGrath; Doren, Bonnie; Fenning, Pamela

    2013-01-01

    Schoolwide positive behavior support (SWPBS) is a systems-level intervention designed to prevent the occurrence of problem behavior and increase social competence. A growing body of research documents that SWPBS reduces problem behavior and improves academics (e.g., McIntosh, Chard, Boland, & Horner, 2006), yet documentation of the feasibility…

  2. Angular Positioning Sensor for Space Mechanisms

    Science.gov (United States)

    Steiner, Nicolas; Chapuis, Dominique

    2013-09-01

    Angular position sensors are used on various rotating mechanisms such as solar array drive mechanisms, antenna pointing mechanisms, scientific instruments, motors or actuators.Now a days, potentiometers and encoders are mainly used for angular measurement purposes. Both of them have their own pros and cons.As alternative, Ruag Space Switzerland Nyon (RSSN) is developing and qualifying two innovative technologies of angular position sensors which offer easy implementation, medium to very high lifetime and high flexibility with regards to the output signal shape/type.The Brushed angular position sensor uses space qualified processes which are already flying on RSSN's sliprings for many years. A large variety of output signal shape can be implemented to fulfill customer requirements (digital, analog, customized, etc.).The contactless angular position sensor consists in a new radiation hard Application Specific Integrated Circuit (ASIC) based on the Hall effect and providing the angular position without complex processing algorithm.

  3. Favorable Local Control From Consolidative Radiation Therapy in High-Risk Neuroblastoma Despite Gross Residual Disease, Positive Margins, or Nodal Involvement

    Energy Technology Data Exchange (ETDEWEB)

    Ferris, Matthew J., E-mail: mjferri@emory.edu [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Danish, Hasan [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Switchenko, Jeffrey M. [Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Department of Biostatistics and Bioinformatics, Emory University, Atlanta, Georgia (United States); Deng, Claudia [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); George, Bradley A.; Goldsmith, Kelly C.; Wasilewski, Karen J.; Cash, W. Thomas [Aflac Cancer and Blood Disorders Center, Children' s Healthcare of Atlanta, Atlanta, Georgia (United States); Khan, Mohammad K.; Eaton, Bree R.; Esiashvili, Natia [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2017-03-15

    Purpose: To report the influence of radiation therapy (RT) dose and surgical pathology variables on disease control and overall survival (OS) in patients treated for high-risk neuroblastoma at a single institution. Methods and Materials: We conducted a retrospective study of 67 high-risk neuroblastoma patients who received RT as part of definitive management from January 2003 until May 2014. Results: At a median follow-up of 4.5 years, 26 patients (38.8%) failed distantly; 4 of these patients also failed locally. One patient progressed locally without distant failure. Local control was 92.5%, and total disease control was 59.5%. No benefit was demonstrated for RT doses over 21.6 Gy with respect to local relapse–free survival (P=.55), disease-free survival (P=.22), or OS (P=.72). With respect to local relapse–free survival, disease-free survival, and OS, no disadvantage was seen for positive lymph nodes on surgical pathology, positive surgical margins, or gross residual disease. Of the patients with gross residual disease, 75% (6 of 8) went on to have no evidence of disease at time of last follow-up, and the 2 patients who failed did so distantly. Conclusions: Patients with high-risk neuroblastoma in this series maintained excellent local control, with no benefit demonstrated for radiation doses over 21.6 Gy, and no disadvantage demonstrated for gross residual disease after surgery, positive surgical margins, or pathologic lymph node positivity. Though the limitations of a retrospective review for an uncommon disease must be kept in mind, with small numbers in some of the subgroups, it seems that dose escalation should be considered only in exceptional circumstances.

  4. High-dose Extended-Field Irradiation and High-Dose-Rate Brachytherapy With Concurrent Chemotherapy for Cervical Cancer With Positive Para-Aortic Lymph Nodes

    International Nuclear Information System (INIS)

    Kim, Young Seok; Kim, Jong Hoon; Ahn, Seung Do; Lee, Sang-wook; Shin, Seong Soo; Nam, Joo-Hyun; Kim, Young-Tak; Kim, Yong-Man; Kim, Jong-Hyeok; Choi, Eun Kyung

    2009-01-01

    Purpose: To determine the efficacy and toxicity of extended-field radiotherapy (RT) with concurrent platinum-based chemotherapy in patients with uterine cervical carcinoma and positive para-aortic nodes. Methods and Materials: We retrospectively reviewed the results for 33 women with Stage IB-IVB cervical cancer. Each patient had received 59.4 Gy, including a three-dimensional conformal boost to the para-aortic lymph nodes and 41.4-50.4 Gy of external beam radiotherapy to the pelvis. Each patient also underwent six or seven applications of high-dose-rate brachytherapy (median, 5 Gy to point A at each session). Results: The median follow-up period of surviving patients was 39 months. The most common acute toxicity was hematologic, observed in 23 women. Severe acute and late gastrointestinal toxicity was observed in 3 and 4 patients, respectively. More than three-quarters of patients showed a complete response, encompassing the primary mass, metastatic pelvic, and para-aortic lymph nodes. Of the 33 women, 15 had no evidence of disease, 6 had persistent disease, 4 developed in-field failures, and 6 developed distant failures. The 5-year overall and disease-free survival rate was 47% and 42%, respectively. Conclusion: Concurrent chemoradiotherapy with extended-field radiotherapy is feasible in women with uterine cervical carcinoma and positive para-aortic lymph nodes, with acceptable late morbidity and a high survival rate, although it was accompanied by substantial acute toxicity.

  5. Cadastral Database Positional Accuracy Improvement

    Science.gov (United States)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  6. Cryotherapy for Intra- and Perianal High-Grade Squamous Intraepithelial Lesions in HIV-Positive Men who have Sex with Men

    NARCIS (Netherlands)

    Siegenbeek van Heukelom, Matthijs L.; Gosens, Karien C. M.; Prins, Jan M.; de Vries, Henry J. C.

    2018-01-01

    Background Available treatment options for anal high-grade squamous intraepithelial lesions (HSIL) in HIV-positive men who have sex with men (MSM) are limited by low response rates and frequent recurrences. Cryotherapy is an established therapeutic option for several pre-malignant skin disorders.

  7. High Hopes: Organizational Position, Employment Experiences, and Women's and Men's Promotion Aspirations.

    Science.gov (United States)

    Cassirer, Naomi; Reskin, Barbara

    2000-01-01

    Analysis of General Social Survey data (n=733) indicated that men attached greater importance to promotion than women because they were more likely in positions with promotion potential. Results support Kanter's thesis that men's and women's positions in the workplace opportunity structure, not gender, shape career attitudes. (Contains 66…

  8. Development of a high average current polarized electron source with long cathode operational lifetime

    Directory of Open Access Journals (Sweden)

    C. K. Sinclair

    2007-02-01

    Full Text Available Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2×10^{5}   C/cm^{2} and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  9. Acute hepatitis B virus infection with simultaneous high HBsAg and high anti-HBs signals in a previously HBV vaccinated HIV-1 positive patient.

    Science.gov (United States)

    van Dommelen, Laura; Verbon, Annelies; van Doorn, H Rogier; Goossens, Valère J

    2010-03-01

    We present a case of a clinical manifest hepatitis B virus infection and a potentially misleading HBV serological profile in an HIV-1 positive patient despite previous HBV vaccination. The patient presented with an acute hepatitis B and there was no indication of chronic HBV infection or the presence of a mutation in the 'a' determinant. Remarkably, simultaneously with high HBV surface antigen and HBV viral load, high anti-HBs antibodies were present. If, due to previous HBV vaccination only anti-HBs was tested in this patient, the result of the high anti-HBs antibodies could be very misleading and offering a false sense of security. Our findings contribute to the ongoing discussion on how to assess HBV specific immunological memory and determining the role of HBV booster vaccinations in immunocompromised individuals.

  10. Co(OH)2/RGO/NiO sandwich-structured nanotube arrays with special surface and synergistic effects as high-performance positive electrodes for asymmetric supercapacitors.

    Science.gov (United States)

    Xu, Han; Zhang, Chi; Zhou, Wen; Li, Gao-Ren

    2015-10-28

    High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (∼1470 F g(-1) at 5 mV s(-1)) and excellent cycling stability with ∼98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg(-1)), a high power density (27.5 kW kg(-1)) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs.

  11. Anti-cooperative supramolecular polymerization: a new K2-K model applied to the self-assembly of perylene bisimide dye proceeding via well-defined hydrogen-bonded dimers.

    Science.gov (United States)

    Gershberg, Jana; Fennel, Franziska; Rehm, Thomas H; Lochbrunner, Stefan; Würthner, Frank

    2016-03-01

    A perylene bisimide dye bearing amide functionalities at the imide positions derived from amino acid l-alanine and a dialkoxy-substituted benzyl amine self-assembles into tightly bound dimers by π-π-stacking and hydrogen bonding in chloroform. In less polar or unpolar solvents like toluene and methylcyclohexane, and in their mixtures, these dimers further self-assemble into extended oligomeric aggregates in an anti-cooperative process in which even numbered aggregates are highly favoured. The stepwise transition from dimers into oligomers can not be properly described by conventional K 2 - K model, and thus a new K 2 - K aggregation model has been developed, which interpretes the present anti-cooperative supramolecular polymerization more appropriately. The newly developed K 2 - K model will be useful to describe self-assembly processes of a plethora of other π-conjugated molecules that are characterized by a favored dimer species.

  12. High Classification Rates for Continuous Cow Activity Recognition using Low-cost GPS Positioning Sensors and Standard Machine Learning Techniques

    DEFF Research Database (Denmark)

    Godsk, Torben; Kjærgaard, Mikkel Baun

    2011-01-01

    activities. By preprocessing the raw cow position data, we obtain high classification rates using standard machine learning techniques to recognize cow activities. Our objectives were to (i) determine to what degree it is possible to robustly recognize cow activities from GPS positioning data, using low...... and their activities manually logged to serve as ground truth. For our dataset we managed to obtain an average classification success rate of 86.2% of the four activities: eating/seeking (90.0%), walking (100%), lying (76.5%), and standing (75.8%) by optimizing both the preprocessing of the raw GPS data...

  13. Electromagnetic Design and Optimization of Directivity of Stripline Beam Position Monitors for the High Luminosity Large Hadron Collider

    CERN Document Server

    Draskovic, Drasko; Jones, Owain Rhodri; Lefèvre, Thibaut; Wendt, Manfred

    2015-01-01

    This paper presents the preliminary electromagnetic design of a stripline Beam Position Monitor (BPM) for the High Luminosity program of the Large Hadron Collider (HL-LHC) at CERN. The design is fitted into a new octagonal shielded Beam Screen for the low-beta triplets and is optimized for high directivity. It also includes internal Tungsten absorbers, required to reduce the energy deposition in the superconducting magnets. The achieved broadband directivity in wakefield solver simulations presents significant improvement over the directivity of the current stripline BPMs installed in the LHC.

  14. Mothering, fathering, and the regulation of negative and positive emotions in high-functioning preschoolers with autism spectrum disorder.

    Science.gov (United States)

    Hirschler-Guttenberg, Yael; Golan, Ofer; Ostfeld-Etzion, Sharon; Feldman, Ruth

    2015-05-01

    Children with autism spectrum disorder (ASD) exhibit difficulties in regulating emotions and authors have called to study the specific processes underpinning emotion regulation (ER) in ASD. Yet, little observational research examined the strategies preschoolers with ASD use to regulate negative and positive emotions in the presence of their mothers and fathers. Forty preschoolers with ASD and 40 matched typically developing children and their mothers and fathers participated. Families were visited twice for identical battery of paradigms with mother or father. Parent-child interactions were coded for parent and child behaviors and children engaged in ER paradigms eliciting negative (fear) and positive (joy) emotions with each parent. ER paradigms were microcoded for negative and positive emotionality, ER strategies, and parent regulation facilitation. During free play, mothers' and fathers' sensitivity and warm discipline were comparable across groups; however, children with ASD displayed lower positive engagement and higher withdrawal. During ER paradigms, children with ASD expressed less positive emotionality overall and more negative emotionality during fear with father. Children with ASD used more simple self-regulatory strategies, particularly during fear, but expressed comparable levels of assistance seeking behavior toward mother and father in negative and positive contexts. Parents of children with ASD used less complex regulation facilitation strategies, including cognitive reappraisal and emotional reframing, and employed simple tactics, such as physical comforting to manage fear and social gaze to maintain joy. Findings describe general and parent- and emotion-specific processes of child ER and parent regulation facilitation in preschoolers with ASD. Results underscore the ability of such children to seek parental assistance during moments of high arousal and the parents' sensitive adaptation to their children's needs. Reduced positive emotionality

  15. Tenofovir treatment in an unselected cohort of highly antiretroviral experienced HIV positive patients

    DEFF Research Database (Denmark)

    Lerbaek, A; Kristiansen, Thomas Birk; Katzenstein, TL

    2004-01-01

    Tenofovir treatment in an unselected cohort of highly antiretroviral experienced HIV positive patients.Lerbaek A, Kristiansen TB, Katzenstein TL, Mathiesen L, Gerstoft J, Nielsen C, Larsen K, Nielsen JO, Obel N, Laursen AL, Nielsen SD. Department of Infectious Diseases, Hvidovre Hospital......, HIV-RNA levels and genotypic resistance were determined at baseline and after 3 and 6 months. After initiation of tenofovir treatment, a mean decrease in HIV-RNA for all 34 patients was observed (-0.43 log1o copies/ml (+/- 1.22) and -0.49 log10 copies/ml (+/- 1.36) after 3 and 6 months, respectively......, respectively). After initiation of tenofovir treatment, no significant increases in CD4 count were observed. All new NRTI-associated mutations could be explained by the background treatment. In conclusion, we observed a significant decrease in HIV-RNA only when tenofovir was prescribed, in conjunction...

  16. Nonimaging speckle interferometry for high-speed nanometer-scale position detection

    NARCIS (Netherlands)

    van Putten, E.G.; Lagendijk, Aart; Mosk, Allard

    2012-01-01

    We experimentally demonstrate a nonimaging approach to displacement measurement for complex scattering materials. By spatially controlling the wavefront of the light that incidents on the material, we concentrate the scattered light in a focus on a designated position. This wavefront acts as a

  17. Methodological Considerations When Quantifying High-Intensity Efforts in Team Sport Using Global Positioning System Technology.

    Science.gov (United States)

    Varley, Matthew C; Jaspers, Arne; Helsen, Werner F; Malone, James J

    2017-09-01

    Sprints and accelerations are popular performance indicators in applied sport. The methods used to define these efforts using athlete-tracking technology could affect the number of efforts reported. This study aimed to determine the influence of different techniques and settings for detecting high-intensity efforts using global positioning system (GPS) data. Velocity and acceleration data from a professional soccer match were recorded via 10-Hz GPS. Velocity data were filtered using either a median or an exponential filter. Acceleration data were derived from velocity data over a 0.2-s time interval (with and without an exponential filter applied) and a 0.3-second time interval. High-speed-running (≥4.17 m/s 2 ), sprint (≥7.00 m/s 2 ), and acceleration (≥2.78 m/s 2 ) efforts were then identified using minimum-effort durations (0.1-0.9 s) to assess differences in the total number of efforts reported. Different velocity-filtering methods resulted in small to moderate differences (effect size [ES] 0.28-1.09) in the number of high-speed-running and sprint efforts detected when minimum duration was GPS. Changes to how high-intensity efforts are defined affect reported data. Therefore, consistency in data processing is advised.

  18. Current models of positive mental health

    Directory of Open Access Journals (Sweden)

    Stanojević Dragana Z.

    2012-01-01

    Full Text Available The concept of positive mental health represents not merely the absence of mental disease but presence of high level of happiness and well-being. In this paper we mentioned shortly the earliest concept of mental health, presented by Marie Jahoda in the mid-twentieth century. After that, we described two traditions in understanding and researching of subjective well-being: hedonic and eudaimonic approach. First approach focuses on investigation of positive affects and happiness as emotional and life satisfaction as cognitive component of subjective well-being. Second tradition emphasizes potentials and competences that person develops to the highest level, in personal and social area. Both psychological and social well-being are core concept of positive mental health psychology, designated together as positive functioning. The psychological well-being comprises six dimensions: self-acceptance, positive relations with others, environmental mastery, autonomy, purpose of life and personal growth. Social well-being consists of five dimensions: social integration, social acceptance, social contribution, social actualization and social coherence. By integrating hedonic and eudaimonic well-being as well as absence of mental disease, Corey Keyes introduced concept of complete mental health. People with complete mental health have reported absence of disease during past year and presence of high level of emotional, psychological and social well-being (flourishing. People with incomplete mental health have also reported absence of mental disease but low level of positive functioning (languishing. Keyes thought there are people with complete and incomplete mental illness; both groups report presence of mental disease, but second group has high level of positive functioning. Models of positive mental health are widely used in research studies as well as in programs for prevention and promotion of mental health. .

  19. High-intensity interval training has positive effects on performance in ice hockey players.

    Science.gov (United States)

    Naimo, M A; de Souza, E O; Wilson, J M; Carpenter, A L; Gilchrist, P; Lowery, R P; Averbuch, B; White, T M; Joy, J

    2015-01-01

    In spite of the well-known benefits that have been shown, few studies have looked at the practical applications of high-intensity interval training (HIIT) on athletic performance. This study investigated the effects of a HIIT program compared to traditional continuous endurance exercise training. 24 hockey players were randomly assigned to either a continuous or high-intensity interval group during a 4-week training program. The interval group (IG) was involved in a periodized HIIT program. The continuous group (CG) performed moderate intensity cycling for 45-60 min at an intensity that was 65% of their calculated heart rate reserve. Body composition, muscle thickness, anaerobic power, and on-ice measures were assessed pre- and post-training. Muscle thickness was significantly greater in IG (p=0.01) when compared to CG. The IG had greater values for both ∆ peak power (p<0.003) and ∆ mean power (p<0.02). Additionally, IG demonstrated a faster ∆ sprint (p<0.02) and a trend (p=0.08) for faster ∆ endurance test time to completion for IG. These results indicate that hockey players may utilize short-term HIIT to elicit positive effects in muscle thickness, power and on-ice performance. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Unambiguous determination of H-atom positions: comparing results from neutron and high-resolution X-ray crystallography.

    Science.gov (United States)

    Gardberg, Anna S; Del Castillo, Alexis Rae; Weiss, Kevin L; Meilleur, Flora; Blakeley, Matthew P; Myles, Dean A A

    2010-05-01

    The locations of H atoms in biological structures can be difficult to determine using X-ray diffraction methods. Neutron diffraction offers a relatively greater scattering magnitude from H and D atoms. Here, 1.65 A resolution neutron diffraction studies of fully perdeuterated and selectively CH(3)-protonated perdeuterated crystals of Pyrococcus furiosus rubredoxin (D-rubredoxin and HD-rubredoxin, respectively) at room temperature (RT) are described, as well as 1.1 A resolution X-ray diffraction studies of the same protein at both RT and 100 K. The two techniques are quantitatively compared in terms of their power to directly provide atomic positions for D atoms and analyze the role played by atomic thermal motion by computing the sigma level at the D-atom coordinate in simulated-annealing composite D-OMIT maps. It is shown that 1.65 A resolution RT neutron data for perdeuterated rubredoxin are approximately 8 times more likely overall to provide high-confidence positions for D atoms than 1.1 A resolution X-ray data at 100 K or RT. At or above the 1.0sigma level, the joint X-ray/neutron (XN) structures define 342/378 (90%) and 291/365 (80%) of the D-atom positions for D-rubredoxin and HD-rubredoxin, respectively. The X-ray-only 1.1 A resolution 100 K structures determine only 19/388 (5%) and 8/388 (2%) of the D-atom positions above the 1.0sigma level for D-rubredoxin and HD-rubredoxin, respectively. Furthermore, the improved model obtained from joint XN refinement yielded improved electron-density maps, permitting the location of more D atoms than electron-density maps from models refined against X-ray data only.

  1. HAMS: High-Affinity Mass Spectrometry Screening. A High-Throughput Screening Method for Identifying the Tightest-Binding Lead Compounds for Target Proteins with No False Positive Identifications.

    Science.gov (United States)

    Imaduwage, Kasun P; Go, Eden P; Zhu, Zhikai; Desaire, Heather

    2016-11-01

    A major challenge in drug discovery is the identification of high affinity lead compounds that bind a particular target protein; these leads are typically identified by high throughput screens. Mass spectrometry has become a detection method of choice in drug screening assays because the target and the ligand need not be modified. Label-free assays are advantageous because they can be developed more rapidly than assays requiring labels, and they eliminate the risk of the label interfering with the binding event. However, in commonly used MS-based screening methods, detection of false positives is a major challenge. Here, we describe a detection strategy designed to eliminate false positives. In this approach, the protein and the ligands are incubated together, and the non-binders are separated for detection. Hits (protein binders) are not detectable by MS after incubation with the protein, but readily identifiable by MS when the target protein is not present in the incubation media. The assay was demonstrated using three different proteins and hundreds of non-inhibitors; no false positive hits were identified in any experiment. The assay can be tuned to select for ligands of a particular binding affinity by varying the quantity of protein used and the immobilization method. As examples, the method selectively detected inhibitors that have K i values of 0.2 μM, 50 pM, and 700 pM. These findings demonstrate that the approach described here compares favorably with traditional MS-based screening methods. Graphical Abstract ᅟ.

  2. MMPI-based employment decisions for high-risk positions in nuclear power settings

    Energy Technology Data Exchange (ETDEWEB)

    Wilikofsky, A.S.

    1986-01-01

    To asses the feasibility of using the Minnesota Multiphasic Personality Inventory (MMPI) as a personnel screening device for high-risk occupations, the test protocols of 735 applicants to and employees of the nuclear facilities owned by a southeastern utility were obtained. Institutional information on initial screening, hiring, and follow-up status was provided. MMPI data were processed to yield pass-and-fail screening decisions using a commercially available computer-based test interpretation system and a locally developed (NC) clerical interpretive system. The latter method was applied both with and without K corrections to component scores. The clerical system using K-corrected scores produced the largest number of true and false positives. The same rules, using uncorrected scores, produced the greatest number of false negatives. The computer-based system produced the most-acceptable set of decisions overall, striking a balance between these two kinds of errors. It was concluded that, when assessed against the available criterion information, the MMPI could not be recommended as a screening device. However, due to serious limitations inherent in these data, further study is needed.

  3. MMPI-based employment decisions for high-risk positions in nuclear power settings

    International Nuclear Information System (INIS)

    Wilikofsky, A.S.

    1986-01-01

    To asses the feasibility of using the Minnesota Multiphasic Personality Inventory (MMPI) as a personnel screening device for high-risk occupations, the test protocols of 735 applicants to and employees of the nuclear facilities owned by a southeastern utility were obtained. Institutional information on initial screening, hiring, and follow-up status was provided. MMPI data were processed to yield pass-and-fail screening decisions using a commercially available computer-based test interpretation system and a locally developed (NC) clerical interpretive system. The latter method was applied both with and without K corrections to component scores. The clerical system using K-corrected scores produced the largest number of true and false positives. The same rules, using uncorrected scores, produced the greatest number of false negatives. The computer-based system produced the most-acceptable set of decisions overall, striking a balance between these two kinds of errors. It was concluded that, when assessed against the available criterion information, the MMPI could not be recommended as a screening device. However, due to serious limitations inherent in these data, further study is needed

  4. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    International Nuclear Information System (INIS)

    Wilbert, Jürgen; Guckenberger, Matthias; Polat, Bülent; Sauer, Otto; Vogele, Michael; Flentje, Michael; Sweeney, Reinhart A

    2010-01-01

    To introduce a novel method of patient positioning for high precision intracranial radiotherapy. An infrared(IR)-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP) and connected to the table via a 6 degree-of-freedom(DoF) mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT) is performed. A robotic 6 DoF treatment couch (HexaPOD™) then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD) of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102) was 1.6 ± 0.8 mm while intra-fraction movement (n = 110) was 0.6 ± 0.4 mm. This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient comfort

  5. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    Directory of Open Access Journals (Sweden)

    Flentje Michael

    2010-05-01

    Full Text Available Abstract Background To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods An infrared(IR-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP and connected to the table via a 6 degree-of-freedom(DoF mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT is performed. A robotic 6 DoF treatment couch (HexaPOD™ then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102 was 1.6 ± 0.8 mm while intra-fraction movement (n = 110 was 0.6 ± 0.4 mm. Conclusions This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient

  6. Gas Pixel Detectors for low energy X-ray polarimetry

    International Nuclear Information System (INIS)

    Spandre, Gloria

    2007-01-01

    Gas Pixel Detectors are position-sensitive proportional counters in which a complete integration between the gas amplification structure and the read-out electronics has been reached. Various generation of Application-Specific Integrated Circuit (ASIC) have been designed in deep submicron CMOS technology to realize a monolithic device which is at the same time the charge collecting electrode and the analog amplifying and charge measuring front-end electronics. The experimental response of a detector with 22060 pixels at 80 μm pitch to polarized and un-polarized X-ray radiation is shown and the application of this device for Astronomical X-ray Polarimetry discussed

  7. Indoor Positioning using Wi-Fi

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Krarup, Mads Vering; Stisen, Allan

    The past decade has witnessed substantial research on methods for indoor Wi-Fi positioning. While much effort has gone into achieving high positioning accuracy and easing fingerprint collection, it is our contention that the general problem is not sufficiently well understood, thus preventing...... deployments and their usage by applications to become more widespread. Based on our own and published experiences on indoor Wi-Fi positioning deployments, we hypothesize the following: Current indoor Wi-Fi positioning systems and their utilization in applications are hampered by the lack of understanding...... of the requirements present in the real-world deployments. In this paper, we report findings from qualitatively studying organisational requirements for indoor Wi-Fi positioning. The studied cases and deployments cover both company and public-sector settings and the deployment and evaluation of several types...

  8. Position detectors, methods of detecting position, and methods of providing positional detectors

    Science.gov (United States)

    Weinberg, David M.; Harding, L. Dean; Larsen, Eric D.

    2002-01-01

    Position detectors, welding system position detectors, methods of detecting various positions, and methods of providing position detectors are described. In one embodiment, a welding system positional detector includes a base that is configured to engage and be moved along a curved surface of a welding work piece. At least one position detection apparatus is provided and is connected with the base and configured to measure angular position of the detector relative to a reference vector. In another embodiment, a welding system positional detector includes a weld head and at least one inclinometer mounted on the weld head. The one inclinometer is configured to develop positional data relative to a reference vector and the position of the weld head on a non-planar weldable work piece.

  9. Changes in balance and joint position sense during a 12-day high altitude trek: The British Services Dhaulagiri medical research expedition.

    Directory of Open Access Journals (Sweden)

    Sarah B Clarke

    Full Text Available Postural control and joint position sense are essential for safely undertaking leisure and professional activities, particularly at high altitude. We tested whether exposure to a 12-day trek with a gradual ascent to high altitude impairs postural control and joint position sense. This was a repeated measures observational study of 12 military service personnel (28±4 years. Postural control (sway velocity measured by a portable force platform during standing balance, a Sharpened Romberg Test and knee joint position sense were measured, in England (113m elevation and at 3 research camps (3619m, 4600m and 5140m on a 12-day high altitude trek in the Dhaulagiri region of Nepal. Pulse oximetry, and Lake Louise scores were also recorded on the morning and evening of each trek day. Data were compared between altitudes and relationships between pulse oximetry, Lake Louise score, and sway velocity were explored. Total sway velocity during standing balance with eyes open (p = 0.003, d = 1.9 and during Sharpened Romberg test with eyes open (p = 0.007, d = 1.6 was significantly greater at altitudes of 3619m and 5140m when compared with sea level. Anterior-posterior sway velocity during standing balance with eyes open was also significantly greater at altitudes of 3619m and 5140m when compared with sea level (p = 0.001, d = 1.9. Knee joint position sense was not altered at higher altitudes. There were no significant correlations between Lake Louise scores, pulse oximetry and postural sway. Despite a gradual ascent profile, exposure to 3619 m was associated with impairments in postural control without impairment in knee joint position sense. Importantly, these impairments did not worsen at higher altitudes of 4600 m or 5140 m. The present findings should be considered during future trekking expeditions when developing training strategies targeted to manage impairments in postural control that occur with increasing altitude.

  10. Changes in balance and joint position sense during a 12-day high altitude trek: The British Services Dhaulagiri medical research expedition.

    Science.gov (United States)

    Clarke, Sarah B; Deighton, Kevin; Newman, Caroline; Nicholson, Gareth; Gallagher, Liam; Boos, Christopher J; Mellor, Adrian; Woods, David R; O'Hara, John P

    2018-01-01

    Postural control and joint position sense are essential for safely undertaking leisure and professional activities, particularly at high altitude. We tested whether exposure to a 12-day trek with a gradual ascent to high altitude impairs postural control and joint position sense. This was a repeated measures observational study of 12 military service personnel (28±4 years). Postural control (sway velocity measured by a portable force platform) during standing balance, a Sharpened Romberg Test and knee joint position sense were measured, in England (113m elevation) and at 3 research camps (3619m, 4600m and 5140m) on a 12-day high altitude trek in the Dhaulagiri region of Nepal. Pulse oximetry, and Lake Louise scores were also recorded on the morning and evening of each trek day. Data were compared between altitudes and relationships between pulse oximetry, Lake Louise score, and sway velocity were explored. Total sway velocity during standing balance with eyes open (p = 0.003, d = 1.9) and during Sharpened Romberg test with eyes open (p = 0.007, d = 1.6) was significantly greater at altitudes of 3619m and 5140m when compared with sea level. Anterior-posterior sway velocity during standing balance with eyes open was also significantly greater at altitudes of 3619m and 5140m when compared with sea level (p = 0.001, d = 1.9). Knee joint position sense was not altered at higher altitudes. There were no significant correlations between Lake Louise scores, pulse oximetry and postural sway. Despite a gradual ascent profile, exposure to 3619 m was associated with impairments in postural control without impairment in knee joint position sense. Importantly, these impairments did not worsen at higher altitudes of 4600 m or 5140 m. The present findings should be considered during future trekking expeditions when developing training strategies targeted to manage impairments in postural control that occur with increasing altitude.

  11. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  12. Polarized neutron reflectometry in high magnetic fields

    International Nuclear Information System (INIS)

    Fritzsche, H.

    2005-01-01

    A simple method is described to maintain the polarization of a neutron beam on its way through the large magnetic stray fields produced by a vertical field of a cryomagnet with a split-coil geometry. The two key issues are the proper shielding of the neutron spin flippers and an additional radial field component in order to guide the neutron spin through the region of the null point (i.e., point of reversal for the vertical field component). Calculations of the neutron's spin rotation as well as polarized neutron reflectometry experiments on an ErFe 2 /DyFe 2 multilayer show the perfect performance of the used setup. The recently commissioned cryomagnet M5 with a maximum vertical field of up to 7.2 T in asymmetric mode for polarized neutrons and 9 T in symmetric mode for unpolarized neutrons was used on the C5 spectrometer in reflectometry mode, at the NRU reactor in Chalk River, Canada

  13. High altitude pulmonary edema and exercise at 4,400 meters on Mount McKinley. Effect of expiratory positive airway pressure.

    Science.gov (United States)

    Schoene, R B; Roach, R C; Hackett, P H; Harrison, G; Mills, W J

    1985-03-01

    Breathing against positive expiratory pressure has been used to improve gas exchange in many forms of pulmonary edema, and forced expiration against resistance during exercise has been advocated for climbing at high altitude as a method to optimize performance. To evaluate the effect of expiratory positive airway pressure (EPAP) on climbers with high altitude pulmonary edema (HAPE) and on exercise at high altitude, we studied four climbers with HAPE at rest and 13 healthy climbers during exercise on a bicycle ergometer at 4400 m. We measured minute ventilation (VI, L/min), arterial oxygen saturation (SaO2 percent), end-tidal carbon dioxide (PACO2, mm Hg), respiratory rate (RR), and heart rate (HR) during the last minute of a five minute interval at rest in the climbers with HAPE, and at rest, 300, and 600 kpm/minute workloads on a bicycle ergometer in the healthy subjects. The HAPE subjects demonstrated an increased SaO2 percent, no change in HR or VI, and a decrease in RR on EPAP as compared to control. In normal subjects, SaO2 percent, VI, and heart rate were significantly higher on EPAP 10 cm H2O than 0 cm H2O control (p less than 0.01, 0.01, and 0.05, respectively). The RR and PaCO2 were not significantly different. In summary, EPAP improves gas exchange in HAPE subjects at rest. The EPAP in normal subjects at high altitude resulted in a higher SaO2 percent at the expense of a higher VI and higher HR. These results suggest that the work of breathing is higher and the stroke volume lower on EPAP. The positive pressure mask may be an effective temporizing measure for victims of HAPE who cannot immediately go to a lower altitude.

  14. High serum coenzyme Q10, positively correlated with age, selenium and cholesterol, in Inuit of Greenland. A pilot study

    DEFF Research Database (Denmark)

    Pedersen, H S; Mortensen, S A; Rohde, M

    1999-01-01

    .001) compared to a Danish population. In a linear multiple regression model the S-CoQ10 level is significantly positively associated with age and S-selenium in males, and S-total cholesterol in females. The high level of CoQ10 in Greenlanders probably reflects diet, since no bioaccumulation takes place...

  15. A Vector Printing Method for High-Speed Electrohydrodynamic (EHD Jet Printing Based on Encoder Position Sensors

    Directory of Open Access Journals (Sweden)

    Thanh Huy Phung

    2018-02-01

    Full Text Available Electrohyrodynamic (EHD jet printing has been widely used in the field of direct micro-nano patterning applications, due to its high resolution printing capability. So far, vector line printing using a single nozzle has been widely used for most EHD printing applications. However, the application has been limited to low-speed printing, to avoid non-uniform line width near the end points where line printing starts and ends. At end points of line vector printing, the deposited drop amount is likely to be significantly large compared to the rest of the printed lines, due to unavoidable acceleration and deceleration. In this study, we proposed a method to solve the printing quality problems by producing droplets at an equally spaced distance, irrespective of the printing speed. For this purpose, an encoder processing unit (EPU was developed, so that the jetting trigger could be generated according to user-defined spacing by using encoder position signals, which are used for the positioning control of the two linear stages.

  16. Calculating TMDs of a large nucleus: Quasi-classical approximation and quantum evolution

    Directory of Open Access Journals (Sweden)

    Yuri V. Kovchegov

    2016-02-01

    Full Text Available We set up a formalism for calculating transverse-momentum-dependent parton distribution functions (TMDs of a large nucleus using the tools of saturation physics. By generalizing the quasi-classical Glauber–Gribov–Mueller/McLerran–Venugopalan approximation to allow for the possibility of spin–orbit coupling, we show how any TMD can be calculated in the saturation framework. This can also be applied to the TMDs of a proton by modeling it as a large “nucleus.” To illustrate our technique, we calculate the quark TMDs of an unpolarized nucleus at large-x: the unpolarized quark distribution and the quark Boer–Mulders distribution. We observe that spin–orbit coupling leads to mixing between different TMDs of the nucleus and of the nucleons. We then consider the evolution of TMDs: at large-x, in the double-logarithmic approximation, we obtain the Sudakov form factor. At small-x the evolution of unpolarized-target quark TMDs is governed by BK/JIMWLK evolution, while the small-x evolution of polarized-target quark TMDs appears to be dominated by the QCD Reggeon.

  17. Polarization of sky light from a canopy atmosphere

    International Nuclear Information System (INIS)

    Hannay, J H

    2004-01-01

    Light from the clear sky is produced by the scattering of unpolarized sunlight by molecules of the atmosphere and is partially linearly polarized in the process. Singly scattered light, for instance, is fully polarized in viewing directions perpendicular to the sun direction and less and less so towards the parallel and antiparallel directions, where it is unpolarized. The true, multiple, scattering is much less tractable, but importantly different, changing the polarization pattern's topology by splitting the unpolarized directions into pairs. The underlying cause of this 'symmetry breaking' is that the atmosphere is 'wider' than it is deep. Simplifying as much as possible while retaining this feature leads to the caricature atmosphere analysed here: a flattened sheet atmosphere in the sky, a canopy. The multiple scattering is fully tractable and leads to a simple polarization pattern in the sky: the ellipses and hyperbolas of standard confocal ellipsoidal coordinates. The model realizes physically a mathematical pattern of polarization in terms of a complex function proposed by Berry, Dennis and Lee (2004 New J. Phys.6 162) as the simplest one which captures the topology

  18. Horizontal Positional Accuracy of Google Earth’s High-Resolution Imagery Archive

    Directory of Open Access Journals (Sweden)

    David Potere

    2008-12-01

    Full Text Available Google Earth now hosts high-resolution imagery that spans twenty percent of the Earth’s landmass and more than a third of the human population. This contemporary highresolution archive represents a significant, rapidly expanding, cost-free and largely unexploited resource for scientific inquiry. To increase the scientific utility of this archive, we address horizontal positional accuracy (georegistration by comparing Google Earth with Landsat GeoCover scenes over a global sample of 436 control points located in 109 cities worldwide. Landsat GeoCover is an orthorectified product with known absolute positional accuracy of less than 50 meters root-mean-squared error (RMSE. Relative to Landsat GeoCover, the 436 Google Earth control points have a positional accuracy of 39.7 meters RMSE (error magnitudes range from 0.4 to 171.6 meters. The control points derived from satellite imagery have an accuracy of 22.8 meters RMSE, which is significantly more accurate than the 48 control-points based on aerial photography (41.3 meters RMSE; t-test p-value < 0.01. The accuracy of control points in more-developed countries is 24.1 meters RMSE, which is significantly more accurate than the control points in developing countries (44.4 meters RMSE; t-test p-value < 0.01. These findings indicate that Google Earth highresolution imagery has a horizontal positional accuracy that is sufficient for assessing moderate-resolution remote sensing products across most of the world’s peri-urban areas.

  19. Optimal design of a double-sided linear motor with a multi-segmented trapezoidal magnet array for a high precision positioning system

    International Nuclear Information System (INIS)

    Lee, Moon G.; Gweon, Dae-Gab

    2004-01-01

    A comparative analysis is performed for linear motors adopting conventional and multi-segmented trapezoidal (MST) magnet arrays, respectively, for a high-precision positioning system. The proposed MST magnet array is a modified version of a Halbach magnet array. The MST array has trapezoidal magnets with variable shape and dimensions while the Halbach magnet array generally has a rectangular magnet with identical dimensions. We propose a new model that can describe the magnetic field resulting from the complex-shaped magnets. The model can be applied to both MST and conventional magnet arrays. Using the model, a design optimization of the two types of linear motors is performed and compared. The magnet array with trapezoidal magnets can produce more force than one with rectangular magnets when they are arrayed in a linear motor where there is a yoke with high permeability. After the optimization and comparison, we conclude that the linear motor with the MST magnet array can generate more actuating force per volume than the motor with the conventional array. In order to satisfy the requirements of next generation systems such as high resolution, high speed, and long stroke, the use of a linear motor with a MST array as an actuator in a high precision positioning system is recommended from the results obtained here

  20. Analysis of tag-position bias in MPSS technology

    Directory of Open Access Journals (Sweden)

    Rattray Magnus

    2006-04-01

    Full Text Available Abstract Background Massively Parallel Signature Sequencing (MPSS technology was recently developed as a high-throughput technology for measuring the concentration of mRNA transcripts in a sample. It has previously been observed that the position of the signature tag in a transcript (distance from 3' end can affect the measurement, but this effect has not been studied in detail. Results We quantify the effect of tag-position bias in Classic and Signature MPSS technology using published data from Arabidopsis, rice and human. We investigate the relationship between measured concentration and tag-position using nonlinear regression methods. The observed relationship is shown to be broadly consistent across different data sets. We find that there exist different and significant biases in both Classic and Signature MPSS data. For Classic MPSS data, genes with tag-position in the middle-range have highest measured abundance on average while genes with tag-position in the high-range, far from the 3' end, show a significant decrease. For Signature MPSS data, high-range tag-position genes tend to have a flatter relationship between tag-position and measured abundance. Thus, our results confirm that the Signature MPSS method fixes a substantial problem with the Classic MPSS method. For both Classic and Signature MPSS data there is a positive correlation between measured abundance and tag-position for low-range tag-position genes. Compared with the effects of mRNA length and number of exons, tag-position bias seems to be more significant in Arabadopsis. The tag-position bias is reflected both in the measured abundance of genes with a significant tag count and in the proportion of unexpressed genes identified. Conclusion Tag-position bias should be taken into consideration when measuring mRNA transcript abundance using MPSS technology, both in Classic and Signature MPSS methods.

  1. A microprogrammable high-speed data collection system for position sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hashizume, H.

    1984-01-01

    A high-speed data acquisition system has been designed which collects digital data from one- and two-dimensional position sensitive X-ray detectors at a maximum average data rate of 1 MHz. The system consists of two separate fast buffer memories, a 64 K word by 20-bit main storage, two timers, a display controller, a computer interface and a keyboard, controlled by a specially designed microprogrammable microprocessor. Data collection is performed by executing a microprogram stored in the control storage; data coming from a detector are first accumulated in a small but fast buffer memory by hardware and transferred to the main storage under control of the microprogram. This design not only permits time-resolved data collections but also provides maximum speed, flexibility and cost-effectiveness simultaneously. The system also accepts data from integrated detectors such as TV cameras. The system has been designed for use in experiments at conventional and synchrotron X-ray sources. (orig.)

  2. Sub-15 nm nano-pattern generation by spacer width control for high density precisely positioned self-assembled device nanomanufacturing

    KAUST Repository

    Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2012-01-01

    We present a conventional micro-fabrication based thin film vertical sidewall (spacer) width controlled nano-gap fabrication process to create arrays of nanopatterns for high density precisely positioned self-assembled nanoelectronics device integration. We have used conventional optical lithography to create base structures and then silicon nitride (Si 3N4) based spacer formation via reactive ion etching. Control of Si3N4 thickness provides accurate control of vertical sidewall (spacer) besides the base structures. Nano-gaps are fabricated between two adjacent spacers whereas the width of the gap depends on the gap between two adjacent base structures minus width of adjacent spacers. We demonstrate the process using a 32 nm node complementary metal oxide semiconductor (CMOS) platform to show its compatibility for very large scale heterogeneous integration of top-down and bottom-up fabrication as well as conventional and selfassembled nanodevices. This process opens up clear opportunity to overcome the decade long challenge of high density integration of self-assembled devices with precise position control. © 2012 IEEE.

  3. Sub-15 nm nano-pattern generation by spacer width control for high density precisely positioned self-assembled device nanomanufacturing

    KAUST Repository

    Rojas, Jhonathan Prieto

    2012-08-01

    We present a conventional micro-fabrication based thin film vertical sidewall (spacer) width controlled nano-gap fabrication process to create arrays of nanopatterns for high density precisely positioned self-assembled nanoelectronics device integration. We have used conventional optical lithography to create base structures and then silicon nitride (Si 3N4) based spacer formation via reactive ion etching. Control of Si3N4 thickness provides accurate control of vertical sidewall (spacer) besides the base structures. Nano-gaps are fabricated between two adjacent spacers whereas the width of the gap depends on the gap between two adjacent base structures minus width of adjacent spacers. We demonstrate the process using a 32 nm node complementary metal oxide semiconductor (CMOS) platform to show its compatibility for very large scale heterogeneous integration of top-down and bottom-up fabrication as well as conventional and selfassembled nanodevices. This process opens up clear opportunity to overcome the decade long challenge of high density integration of self-assembled devices with precise position control. © 2012 IEEE.

  4. High Prevalence and Significance of Hepatitis D Virus Infection among Treatment-Naïve HBsAg-Positive Patients in Northern Vietnam

    Science.gov (United States)

    Sy, Bui Tien; Ratsch, Boris A.; Toan, Nguyen Linh; Song, Le Huu; Wollboldt, Christian; Bryniok, Agnes; Nguyen, Hung Minh; Luong, Hoang Van; Velavan, Thirumalaisamy P.; Wedemeyer, Heiner; Kremsner, Peter G.; Bock, C.-Thomas

    2013-01-01

    Background Hepatitis D virus (HDV) infection is considered to cause more severe hepatitis than hepatitis B virus (HBV) monoinfection. With more than 9.5 million HBV-infected people, Vietnam will face an enormous health burden. The prevalence of HDV in Vietnamese HBsAg-positive patients is speculative. Therefore, we assessed the prevalence of HDV in Vietnamese patients, determined the HDV-genotype distribution and compared the findings with the clinical outcome. Methods 266 sera of well-characterized HBsAg-positive patients in Northern Vietnam were analysed for the presence of HDV using newly developed HDV-specific RT-PCRs. Sequencing and phylogenetic analysis were performed for HDV-genotyping. Results The HDV-genome prevalence observed in the Vietnamese HBsAg-positive patients was high with 15.4% while patients with acute hepatitis showed 43.3%. Phylogenetic analysis demonstrated a predominance of HDV-genotype 1 clustering in an Asian clade while HDV-genotype 2 could be also detected. The serum aminotransferase levels (AST, ALT) as well as total and direct bilirubin were significantly elevated in HDV-positive individuals (p<0.05). HDV loads were mainly low (<300 to 4.108 HDV-copies/ml). Of note, higher HDV loads were mainly found in HBV-genotype mix samples in contrast to single HBV-infections. In HBV/HDV-coinfections, HBV loads were significantly higher in HBV-genotype C in comparison to HBV-genotype A samples (p<0.05). Conclusion HDV prevalence is high in Vietnamese individuals, especially in patients with acute hepatitis B. HDV replication activity showed a HBV-genotype dependency and could be associated with elevated liver parameters. Besides serological assays molecular tests are recommended for diagnosis of HDV. Finally, the high prevalence of HBV and HDV prompts the urgent need for HBV-vaccination coverage. PMID:24205106

  5. A highly restricted T-cell receptor dominates the CD8+ T-cell response to parvovirus B19 infection in HLA-A*2402-positive individuals

    DEFF Research Database (Denmark)

    Kasprowicz, V; Isa, Adiba; Jeffery, K

    2006-01-01

    Six of seven HLA-A*2402-positive individuals with acute parvovirus B19 infections made vigorous CD8-positive cytotoxic T-cell (CTL) responses to the viral epitope FYTPLADQF. All responders showed highly focused T-cell receptor (TCR) usage, using almost exclusively BV5.1. The BV5.1 TCR dominated...

  6. Final Technical Report Project: Low-Energy Photonuclear Studies at HIGS and Lund

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, Gerald [George Washington Univ., Washington, DC (United States)

    2017-06-15

    This report summarizes a program of low-energy photonuclear studies at MAX-Lab in Lund (Sweden) and at the High Intensity Gamma Source (HIGS) at Duke University. A major emphasis has been on Compton scattering from deuterium in order to determine the electric and magnetic polarizabilities of the neutron. The studies at Lund utilized unpolarized photons at Egamma = 62-115 MeV to measure differential cross sections. The studies at HIGS utilized polarized and unpolarized photon beams (both linear and circular) at Egamma < 90 MeV. Polarization observables will be exploited to improve our understanding of the electric and magnetic polarizabilities, and in particular, double-polarization observables (using polarized targets) will be measured in the future to provide new information about the spin polarizabilities of the nucleon. The MAX-Lab experiments (using unpolarized photons) focused on an approved PAC proposal for Compton scattering on the deuteron aimed at making a precise determination of the electromagnetic polarizabilities of the neutron. At MAX-Lab we had three of the largest NaI detectors in the world, each capable of ~2% energy resolution. We have completed our measurements in two separate tagged photon energy ranges which overlap each other (62-97 MeV and 90-115 MeV) and the results of these experiments have been published. The photon beam at the High Intensity Gamma Source (HIGS) has several distinct advantages that make it unique: (1) ultra-high photon flux, ultimately reaching 100 MHz, (2) 100% linearly polarized photon beam, as well as circular polarization, (3) monoenergetic beam, with ~2% energy resolution, and (4) extremely low-background beam environment. Exploiting the high flux and polarization capabilities of the HIGS photon beam is central in the series of experiments being performed at this facility. Very little data exist on Compton scattering using polarized photons. We will exploit clear sensitivities in the polarization observables to the

  7. Long-term use of first-line highly active antiretroviral therapy is not associated with carotid artery stiffness in human immunodeficiency virus-positive patients

    Directory of Open Access Journals (Sweden)

    Haohui Zhu

    2014-09-01

    Conclusion: The first-line highly active antiretroviral therapy currently used in China is not associated with carotid artery stiffness in human immunodeficiency virus-positive patients with good highly active antiretroviral therapy compliance. Human immunodeficiency virus may play a role in the development of atherosclerosis.

  8. Unpolarized structure functions and the parton distributions for ...

    Indian Academy of Sciences (India)

    The predictive power of the model to be adopted here has been am- ply demonstrated in wide ranging low energy hadronic phenomena which include the ... integral from m = 1 to ½; analytic evaluation of the integral yields the exact normaliza- tions, demonstrating the minimal effects of the support problem. Therefore we ...

  9. Unpolarized coupled DGLAP evolution equation at small-x

    Indian Academy of Sciences (India)

    Department of Physics, Tezpur University, Napaam 784 028, India; Department of Physics, J.N. College, Boko 781 123, India ... The domain part of the email address of all email addresses used by the office of Indian Academy of Sciences, including those of the staff, the journals, various ... Please take note of this change.

  10. Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

    International Nuclear Information System (INIS)

    Yoon, Phil S.; Siddons, D. Peter

    2010-01-01

    We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

  11. High energy electron radiography system design and simulation study of beam angle-position correlation and aperture effect on the images

    International Nuclear Information System (INIS)

    Zhao, Quantang; Cao, S.C.; Liu, M.; Sheng, X.K.; Wang, Y.R.; Zong, Y.; Zhang, X.M.; Jing, Y.; Cheng, R.; Zhao, Y.T.; Zhang, Z.M.; Du, Y.C.; Gai, W.

    2016-01-01

    A beam line dedicated to high-energy electron radiography experimental research with linear achromat and imaging lens systems has been designed. The field of view requirement on the target and the beam angle-position correlation correction can be achieved by fine-tuning the fields of the quadrupoles used in the achromat in combination with already existing six quadrupoles before the achromat. The radiography system is designed by fully considering the space limitation of the laboratory and the beam diagnostics devices. Two kinds of imaging lens system, a quadruplet and an octuplet system are integrated into one beam line with the same object plane and image plane but with different magnification factor. The beam angle-position correlation on the target required by the imaging lens system and the aperture effect on the images are studied with particle tracking simulation. It is shown that the aperture position is also correlated to the beam angle-position on the target. With matched beam on the target, corresponding aperture position and suitable aperture radius, clear pictures can be imaged by both lens systems. The aperture is very important for the imaging. The details of the beam optical requirements, optimized parameters and the simulation results are presented.

  12. The positive impact of radiologic imaging on high-stage cutaneous squamous cell carcinoma management.

    Science.gov (United States)

    Ruiz, Emily Stamell; Karia, Pritesh S; Morgan, Frederick C; Schmults, Chrysalyne D

    2017-02-01

    There is limited evidence on the utility of radiologic imaging for prognostic staging of cutaneous squamous cell carcinoma (CSCC). Review utilization of radiologic imaging of high-stage CSCCs to evaluate whether imaging impacted management and outcomes. Tumors classified as Brigham and Women's Hospital (BWH) tumor (T) stage T2B or T3 over a 13-year period were reviewed to identify whether imaging was performed and whether results affected treatment. Disease-related outcomes (DRO: local recurrence, nodal metastasis, death from disease) were compared between patients by type of imaging used. 108 high-stage CSCCs in 98 patients were included. Imaging (mostly computed tomography, 79%) was utilized in 45 (46%) patients and management was altered in 16 (33%) patients who underwent imaging. Patients that received no imaging were at higher risk of developing nodal metastases (nonimaging, 30%; imaging, 13%; P = .041) and any DRO (nonimaging, 42%; imaging, 20%; P = .028) compared to the imaging group. Imaging was associated with a lower risk for DRO (subhazard ratio, 0.5; 95% CI 0.2-0.9; P = .046) adjusted for BWH T stage, sex, and location. Single institution retrospective design and changes in technology overtime. Radiologic imaging of high-stage CSCC may influence management and appears to positively impact outcomes. Further prospective studies are needed to establish which patients benefit from imaging. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  13. [Radiotherapy in node-positive prostate cancer].

    Science.gov (United States)

    Bottke, D; Bartkowiak, D; Bolenz, C; Wiegel, T

    2016-03-01

    There are numerous randomized trials to guide the management of patients with localized (and metastatic) prostate cancer, but only a few (mostly retrospective) studies have specifically addressed node-positive patients. Therefore, there is uncertainty regarding optimal treatment in this situation. Current guidelines recommend long-term androgen deprivation therapy (ADT) alone or radiotherapy plus long-term ADT as treatment options. This overview summarizes the existing literature on the use of radiotherapy for node-positive prostate cancer as definitive treatment and as adjuvant or salvage therapy after radical prostatectomy. In this context, we also discuss several PET tracers in the imaging evaluation of patients with biochemical recurrence of prostate cancer after radical prostatectomy. As for definitive treatment, retrospective studies suggest that ADT plus radiotherapy improves overall survival compared with ADT alone. These studies also consistently demonstrated that many patients with node-positive prostate cancer can achieve long-term survival - and are likely curable - with aggressive therapy. The beneficial impact of adjuvant radiotherapy on survival in patients with pN1 prostate cancer seems to be highly influenced by tumor characteristics. Men with ≤ 2 positive lymph nodes in the presence of intermediate- to high-grade disease, or positive margins, and those with 3 or 4 positive lymph nodes are the ideal candidates for adjuvant radiotherapy (plus long-term ADT) after surgery. There is a need for randomized trials to further examine the potential role of radiotherapy as either definitive or adjuvant treatment, for patients with node-positive prostate cancer.

  14. High HIV Prevalence, Suboptimal HIV Testing, and Low Knowledge of HIV-Positive Serostatus Among Injection Drug Users in St. Petersburg, Russia

    Science.gov (United States)

    Toussova, Olga V.; Verevochkin, Sergei V.; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P.

    2011-01-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting. PMID:18843531

  15. Heavy Flavour Production as Probe of Gluon Sivers Function

    International Nuclear Information System (INIS)

    Godbole, Rohini M.; Kaushik, Abhiram; Misra, Anuradha; Rawoot, Vaibhav; Sonawane, Bipin

    2017-01-01

    Heavy flavour production like J/ψ and D-meson production in scattering of electrons/unpolarized protons off polarized proton target offer promising probes to investigate gluon Sivers function. In this talk, I will summarize our recent work on transverse single spin asymmetry in J/ψ-production and D-meson production in pp↑ scattering using a generalized parton model approach. We compare predictions obtained using different models of gluon Sivers function within this approach and then, taking into account the transverse momentum dependent evolution of the unpolarized parton distribution functions and gluon Sivers function, we study the effect of evolution on asymmetry. (author)

  16. In Vitro Polarized Resonance Raman Study of N719 and N719-TBP in Dye Sensitized Solar Cells

    DEFF Research Database (Denmark)

    Hassing, Søren; Jernshøj, Kit Drescher; Nguyen, Phuong Tuyet

    2016-01-01

    Abstract: The working efficiency of dye-sensitized solar cells (DSCs) depends on the long-term stability of the dye itself and on the microscopic structure of the dye-semiconductor interface. Previous experimental studies of DSCs based on ruthenium dye with bipyridine ligands (N719) adsorbed...... to the TiO2substrate applied FTIR,un-polarized Raman (RS) and un-polarized resonance Raman (RRS) spectroscopy. In the un-polarized RRS studies of N719/TiO2 – DSCs the discussion of the adsorption of N719 was based on the rather weak carbonyl or carboxyl group stretching vibrations and on minor spectral...

  17. Molecular anisotropy effects in carbon K-edge scattering: depolarized diffuse scattering and optical anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Kevin H.

    2014-07-14

    Some polymer properties, such as conductivity, are very sensitive to short- and intermediate-range orientational and positional ordering of anisotropic molecular functional groups, and yet means to characterize orientational order in disordered systems are very limited. We demonstrate that resonant scattering at the carbon K-edge is uniquely sensitive to short-range orientation correlations in polymers through depolarized scattering at high momentum transfers, using atactic polystyrene as a well-characterized test system. Depolarized scattering is found to coexist with unpolarized fluorescence, and to exhibit pronounced anisotropy. We also quantify the spatially averaged optical anisotropy from low-angle reflectivity measurements, finding anisotropy consistent with prior visible, x-ray absorption, and theoretical studies. The average anisotropy is much smaller than that in the depolarized scattering and the two have different character. Both measurements exhibit clear spectral signatures from the phenyl rings and the polyethylene-like backbone. Discussion focuses on analysis considerations and prospects for using this depolarized scattering for studies of disorder in soft condensed matter.

  18. Measurement and stabilization of the longitudinal and transversal tune on the fast energy ramp at ELSA

    Energy Technology Data Exchange (ETDEWEB)

    Eberhardt, Maren [Electron Stretcher Accelerator ELSA, Physikalisches Institut, Universitaet Bonn (Germany)

    2008-07-01

    At the electron stretcher accelerator ELSA, an external beam of unpolarized or polarized electrons is supplied to experimental set-ups. In order to correct for dynamic effects caused by eddy currents induced on the fast energy ramp, the accelerator tunes have to measured in situ with high precision. The measurements of betatron tunes during the fast energy ramp are based on the excitation of coherent betatron oscillations generated by a pulsed kicker magnet. The betatron frequency is determined by a Fourier analysis of the measured oscillations of the beam position. This technique was successfully applied to measure the horizontal tune on the fast energy ramp. During the fast energy ramp shifts of the betatron tune caused by eddy currents are induced. These tune shifts are measured and corrected when operating the accelerator with polarized beam. Measurements of coherent synchrotron oscillations will also be presented. These are excited by a phase modulation of the acceleration voltage using an electrical phase shifter in the reference RF signal path.

  19. Atypical squamous cells, cannot exclude high grade squamous intraepithelial (ASC-H in HIV-positive women

    Directory of Open Access Journals (Sweden)

    Michelow Pam

    2010-01-01

    Full Text Available Objective: South Africa has very high rates of both HIV infection and cervical pathology. The management of ASC-H is colposcopy and directed biopsy, but with so many women diagnosed with HSIL and a dearth of colposcopy centres in South Africa, women with cytologic diagnosis of ASC-H may not be prioritized for colposcopy. The aim of this study was to determine if HIV-positive women with a cytologic diagnosis of ASC-H should undergo immediate colposcopy or whether colposcopy can be delayed, within the context of an underfunded health care setting with so many competing health needs. Materials and Methods: A computer database search was performed from the archives of an NGO-administered clinic that offers comprehensive HIV care. All women with a cytologic diagnosis of ASC-H on cervical smears from September 2005 until August 2009 were identified. Histologic follow up was sought in all patients. Results: A total of 2111 cervical smears were performed and 41 diagnosed as ASC-H (1.94%. No histologic follow up data was available in 15 cases. Follow up histologic results were as follows: three negative (11.5%, five koilocytosis and/ or CIN1 (19.2%, ten CIN2 (38.5% and eight CIN3 (30.8%. There were no cases of invasive carcinoma on follow up. Conclusion: The current appropriate management of HIV-positive women in low-resource settings with a diagnosis of ASC-H on cervical smear is colposcopy, despite the costs involved. In the future and if cost-effective in developing nations, use of novel markers may help select which HIV-positive women can be managed conservatively and which ones referred for more active treatment. More research in this regard is warranted.

  20. Comparison of laser welds in thick section S700 high-strength steel manufactured in flat (1G) and horizontal (2G) positions

    OpenAIRE

    Guo, Wei; Liu, Qiang; Francis, John Anthony; Crowther, Dave; Thompson, Alan; Liu, Zhu; Li, Lin

    2015-01-01

    Lack of penetration, undercut and melt sagging are common welding defects for single-pass laser welds in thick plates, particularly when using a traditional 1G welding position (laser directed towards ground). This investigation shows, for the first time, that welding 13 mm thick high-strength S700 steel plates in the 2G position (laser beam perpendicular to the direction of gravity) can mitigate some of the common welding defects including undercut and sagging. A computational fluid dynamic ...

  1. Development of X-Y servo pneumatic-piezoelectric hybrid actuators for position control with high response, large stroke and nanometer accuracy.

    Science.gov (United States)

    Chiang, Mao-Hsiung

    2010-01-01

    This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.

  2. Development of X-Y Servo Pneumatic-Piezoelectric Hybrid Actuators for Position Control with High Response, Large Stroke and Nanometer Accuracy

    Directory of Open Access Journals (Sweden)

    Mao-Hsiung Chiang

    2010-03-01

    Full Text Available This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm and nanometer accuracy (20 nm. In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.

  3. Arterial spin labeling-based Z-maps have high specificity and positive predictive value for neurodegenerative dementia compared to FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Faellmar, David; Larsson, Elna-Marie [Uppsala University, Department of Surgical Sciences, Radiology, Uppsala (Sweden); Haller, Sven [Uppsala University, Department of Surgical Sciences, Radiology, Uppsala (Sweden); University Medical Center Freiburg, Department of Neuroradiology, Freiburg (Germany); University of Geneva, Faculty of Medicine, Geneva (Switzerland); Affidea CDRC - Centre Diagnostique Radiologique de Carouge, Carouge (Switzerland); Lilja, Johan [Uppsala University, Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala (Sweden); Hermes Medical Solutions, Stockholm (Sweden); Danfors, Torsten [Uppsala University, Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala (Sweden); Kilander, Lena [Uppsala University, Department of Public Health and Caring Sciences, Geriatrics, Uppsala (Sweden); Tolboom, Nelleke; Croon, Philip M.; Berckel, Bart N.M. van [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Egger, Karl [University Medical Center Freiburg, Department of Neuroradiology, Freiburg (Germany); Kellner, Elias [Medical Center University of Freiburg, Department of Radiology, Medical Physics, Faculty of Medicine, Freiburg (Germany); Verfaillie, Sander C.J.; Ossenkoppele, Rik [VU University Medical Center, Department of Neurology, Alzheimer Center Amsterdam, Amsterdam (Netherlands); Barkhof, Frederik [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); UCL, Institutes of Neurology and Healthcare Engineering, London (United Kingdom)

    2017-10-15

    Cerebral perfusion analysis based on arterial spin labeling (ASL) MRI has been proposed as an alternative to FDG-PET in patients with neurodegenerative disease. Z-maps show normal distribution values relating an image to a database of controls. They are routinely used for FDG-PET to demonstrate disease-specific patterns of hypometabolism at the individual level. This study aimed to compare the performance of Z-maps based on ASL to FDG-PET. Data were combined from two separate sites, each cohort consisting of patients with Alzheimer's disease (n = 18 + 7), frontotemporal dementia (n = 12 + 8) and controls (n = 9 + 29). Subjects underwent pseudocontinuous ASL and FDG-PET. Z-maps were created for each subject and modality. Four experienced physicians visually assessed the 166 Z-maps in random order, blinded to modality and diagnosis. Discrimination of patients versus controls using ASL-based Z-maps yielded high specificity (84%) and positive predictive value (80%), but significantly lower sensitivity compared to FDG-PET-based Z-maps (53% vs. 96%, p < 0.001). Among true-positive cases, correct diagnoses were made in 76% (ASL) and 84% (FDG-PET) (p = 0.168). ASL-based Z-maps can be used for visual assessment of neurodegenerative dementia with high specificity and positive predictive value, but with inferior sensitivity compared to FDG-PET. (orig.)

  4. A Bridge to the Stars: A Model High School-to-College Pipeline for Encouraging Positive STEM Identities

    Science.gov (United States)

    McIntosh, Daniel H.; Jennings, Derrick H.

    2018-01-01

    The need to grow and diversify the STEM workforce remains a critical national challenge. Research shows that STEM identity (how one views herself/himself with respect to STEM) is an important factor for success or failure. A Bridge to the Stars (ABttS) offers URM and low-income high-school students a high impact exposure to science through innovative experiential learning with a professional scientist in freshmen astronomy at UMKC, an urban research university. Showing students who traditionally do not self-identify with high-tech careers that they can succeed in a university science course is a promising way to help build positive STEM identities and aspirations during the critical bridge between high school and college. In five years, we have awarded 45 ABttS scholarships; 93% of these 15-17 year-old students have passed the course satisfactorily with an average grade of 80%. Remarkably, the ABttS scholar performance is on par with that of 600 UMKC students enrolled in the same courses over 8 semesters. Long-term tracking of former scholars shows positive attitudes regarding ABttS and persistence in STEM aspirations at promising rates based on small-number statistics. I will describe the implementation of this unique STEM immersion program offering extended and inclusive engagement in astronomy, arguably the most accessible window to science. I will share classroom and near-peer mentoring innovations, and a new third ABttS tier in which previous scholars can enroll in a freshmen science laboratory experience for UMKC credit. This novel course introduces novices to scientific research and Big Data science through authentic hands-on experiences centered on their own exploration of data from McIntosh's actual research. The long-term mission of ABttS is to see urban educational institutions across the U.S. adopt similar pipelines in all STEM disciplines built on the ABttS model. Adopting programs like ABttS for freshmen STEM majors, especially in urban colleges and

  5. Improved spring model-based collaborative indoor visible light positioning

    Science.gov (United States)

    Luo, Zhijie; Zhang, WeiNan; Zhou, GuoFu

    2016-06-01

    Gaining accuracy with indoor positioning of individuals is important as many location-based services rely on the user's current position to provide them with useful services. Many researchers have studied indoor positioning techniques based on WiFi and Bluetooth. However, they have disadvantages such as low accuracy or high cost. In this paper, we propose an indoor positioning system in which visible light radiated from light-emitting diodes is used to locate the position of receivers. Compared with existing methods using light-emitting diode light, we present a high-precision and simple implementation collaborative indoor visible light positioning system based on an improved spring model. We first estimate coordinate position information using the visible light positioning system, and then use the spring model to correct positioning errors. The system can be employed easily because it does not require additional sensors and the occlusion problem of visible light would be alleviated. We also describe simulation experiments, which confirm the feasibility of our proposed method.

  6. Neutron spectral modulation as a new thermal neutron scattering technique. Pt. 1

    International Nuclear Information System (INIS)

    Ito, Y.; Nishi, M.; Motoya, K.

    1982-01-01

    A thermal neutron scattering technique is presented based on a new idea of labelling each neutron in its spectral position as well as in time through the scattering process. The method makes possible the simultaneous determination of both the accurate dispersion relation and its broadening by utilizing the resolution cancellation property of zero-crossing points in the cross-correlated time spectrum together with the Fourier transform scheme of the neutron spin echo without resorting to the echoing. The channel Fourier transform applied to the present method also makes possible the determination of the accurate direct energy scan profile of the scattering function with a rather broad incident neutron wavelength distribution. Therefore the intensity sacrifice for attaining high accurarcy is minimized. The technique is used with either a polarized or unpolarized beam at the sample position with no precautions against beam depolarization at the sample for the latter case. Relative time accurarcy of the order of 10 -3 to 10 -4 may be obtained for the general dispersion relation and for the quasi-elastic energy transfers using correspondingly the relative incident neutron wavelength spread of 10 to 1% around an incident neutron energy of a few meV. (orig.)

  7. Do positive children become positive adults? Evidence from a longitudinal birth cohort study.

    Science.gov (United States)

    Richards, Marcus; Huppert, Felicia A

    2011-02-10

    BACKGROUND: Little is known about the long-term consequences of positive wellbeing in childhood in the general population. We used the MRC National Survey of Health and Development (the British 1946 birth cohort) to test associations between adolescent positive wellbeing and social functioning in midlife. METHOD: Temperament and behaviour at ages 13 and 15 years were rated by school teachers on a range of criteria. These mostly referred to absence or presence of conduct and emotional problems, but four items allowed positive ratings: 'very popular with other children', 'unusually happy and contented', 'makes friends extremely easily' and 'extremely energetic, never tired'. In addition, at age 16 years survey members self-completed the Maudsley Personality Inventory, from which a summary measure of extraversion was derived, as this was previously found to be associated with midlife positive wellbeing in this cohort. RESULTS: Being a happy child, defined as receiving at least two of the above teacher ratings, was positively associated with midlife functioning and wellbeing, specifically a low probability of lifetime emotional problems, a high frequency of contact with friends or relatives, engagement in social activities, and to a lesser extent feeling satisfied with accomplishments in working life. These associations were independent of father's social class, childhood cognition, educational attainment, and midlife occupational social class. There were no independent associations between being a happy child and educational or occupational attainment, being married, engagement in prosocial activities, taking leadership in community activities, and with life satisfaction in general or with family life. Extraversion was associated with a low probability of lifetime emotional problems, high engagement in social activities, being married, general midlife life satisfaction, and satisfaction with family life, but not with social contact, prosocial activity, leadership

  8. Development of a multiplexed readout with high position resolution for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sangwon; Choi, Yong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of); Kang, Jihoon [Department of Biomedical Engineering, Chonnam National University, Yeosu 550-749 (Korea, Republic of); Jung, Jin Ho [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of)

    2017-04-01

    Detector signals for positron emission tomography (PET) are commonly multiplexed to reduce the number of digital processing channels so that the system can remain cost effective while also maintaining imaging performance. In this work, a multiplexed readout combining Anger position estimation algorithm and position decoder circuit (PDC) was developed to reduce the number of readout channels by a factor of 24, 96-to-4. The data acquisition module consisted of a TDC (50 ps resolution), 4-channel ADCs (12 bit, 105 MHz sampling rate), 2 GB SDRAM and USB3.0. The performance of the multiplexed readout was assessed with a high-resolution PET detector block composed of 2×3 detector modules, each consisting of an 8×8 array of 1.52×1.52×6 mm{sup 3} LYSO, a 4×4 array of 3×3 mm{sup 2} silicon photomultiplier (SiPM) and 13.4×13.4 mm{sup 2} light guide with 0.7 mm thickness. The acquired flood histogram showed that all 384 crystals could be resolved. The average energy resolution at 511 keV was 13.7±1.6% full-width-at-half-maximum (FWHM) and the peak-to-valley ratios of the flood histogram on the horizontal and vertical lines were 18.8±0.8 and 22.8±1.3, respectively. The coincidence resolving time of a pair of detector blocks was 6.2 ns FWHM. The reconstructed phantom image showed that rods down to a diameter of 1.6 mm could be resolved. The results of this study indicate that the multiplexed readout would be useful in developing a PET with a spatial resolution less than the pixel size of the photosensor, such as a SiPM array.

  9. Systematic analysis of immune infiltrates in high-grade serous ovarian cancer reveals CD20, FoxP3 and TIA-1 as positive prognostic factors.

    Directory of Open Access Journals (Sweden)

    Katy Milne

    Full Text Available BACKGROUND: Tumor-infiltrating T cells are associated with survival in epithelial ovarian cancer (EOC, but their functional status is poorly understood, especially relative to the different risk categories and histological subtypes of EOC. METHODOLOGY/PRINCIPAL FINDINGS: Tissue microarrays containing high-grade serous, endometrioid, mucinous and clear cell tumors were analyzed immunohistochemically for the presence of lymphocytes, dendritic cells, neutrophils, macrophages, MHC class I and II, and various markers of activation and inflammation. In high-grade serous tumors from optimally debulked patients, positive associations were seen between intraepithelial cells expressing CD3, CD4, CD8, CD45RO, CD25, TIA-1, Granzyme B, FoxP3, CD20, and CD68, as well as expression of MHC class I and II by tumor cells. Disease-specific survival was positively associated with the markers CD8, CD3, FoxP3, TIA-1, CD20, MHC class I and class II. In other histological subtypes, immune infiltrates were less prevalent, and the only markers associated with survival were MHC class II (positive association in endometrioid cases and myeloperoxidase (negative association in clear cell cases. CONCLUSIONS/SIGNIFICANCE: Host immune responses to EOC vary widely according to histological subtype and the extent of residual disease. TIA-1, FoxP3 and CD20 emerge as new positive prognostic factors in high-grade serous EOC from optimally debulked patients.

  10. Study of a high-resolution, 3-D positioning cadmium zinc telluride detector for PET

    Science.gov (United States)

    Gu, Y; Matteson, J L; Skelton, R T; Deal, A C; Stephan, E A; Duttweiler, F; Gasaway, T M; Levin, C S

    2011-01-01

    This paper investigates the performance of 1 mm resolution Cadmium Zinc Telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3-D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06±0.39% at 511 keV throughout most the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44±0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78±0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes – as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system. PMID:21335649

  11. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

    Science.gov (United States)

    Gu, Y; Matteson, J L; Skelton, R T; Deal, A C; Stephan, E A; Duttweiler, F; Gasaway, T M; Levin, C S

    2011-03-21

    This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06 ± 0.39% at 511 keV throughout most of the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44 ± 0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78 ± 0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes-as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system.

  12. The value of high-resolution anoscopy in the diagnosis of anal cancer precursor lesions in hiv-positive patients

    Directory of Open Access Journals (Sweden)

    Felicidad Gimenez

    2011-06-01

    Full Text Available CONTEXT: Anal cancer, although a still rare disease, is being observed in ascending rates among some population segments known to be at risk for the development of the disease. Human papillomavirus (HPV infection, immunodepression and anal intercourse are some factors associated with the development of the malignancy. Its similarities to cervical cancer have led to many studies aiming to establish guidelines for detecting and treating precursor lesions of anal cancer, with the goal of prevention. High-resolution anoscopy is routinely used for the diagnosis of anal cancer precursor lesions in many centers but the medical literature is still deficient concerning the role of this diagnostic modality. OBJECTIVES: To evaluate diagnostic validation and precision measures of high-resolution anoscopy in comparison to histopathological results of anal biopsies performed in HIV-positive patients treated at the Tropical Medicine Foundation of Amazonas, AM, Brazil. To observe any possible association between some risk factors for the development of anal cancer and the presence of anal squamous intraepithelial lesions. METHODS: A hundred and twenty-eight HIV-positive patients were submitted to anal canal cytological sampling for the detection of HPV infection by a PCR based method. High-resolution anoscopy was then performed after topical application of acetic acid 3% in the anal canal for 2 minutes. Eventual acetowhite lesions that were detected were recorded in respect to location, and classified by their tinctorial pattern, distribution aspect, relief, surface and vascular pattern. Biopsies of acetowhite lesions were performed under local anesthesia and the specimens sent to histopathological analysis. The patients were interviewed for the presence of anal cancer risk factors. RESULTS: The prevalences of anal HPV infection and of anal squamous intraepithelial lesions in the studied population were, respectively, 79% and 39.1%. High-resolution anoscopy

  13. Dependence of Arctic climate on the latitudinal position of stationary waves and to high-latitudes surface warming

    Science.gov (United States)

    Shin, Yechul; Kang, Sarah M.; Watanabe, Masahiro

    2017-12-01

    Previous studies suggest large uncertainties in the stationary wave response under global warming. Here, we investigate how the Arctic climate responds to changes in the latitudinal position of stationary waves, and to high-latitudes surface warming that mimics the effect of Arctic sea ice loss under global warming. To generate stationary waves in an atmospheric model coupled to slab ocean, a series of experiments is performed where the thermal forcing with a zonal wavenumber-2 (with zero zonal-mean) is prescribed at the surface at different latitude bands in the Northern Hemisphere. When the stationary waves are generated in the subtropics, the cooling response dominates over the warming response in the lower troposphere due to cloud radiative effects. Then, the low-level baroclinicity is reduced in the subtropics, which gives rise to a poleward shift of the eddy driven jet, thereby inducing substantial cooling in the northern high latitudes. As the stationary waves are progressively generated at higher latitudes, the zonal-mean climate state gradually becomes more similar to the integration with no stationary waves. These differences in the mean climate affect the Arctic climate response to high-latitudes surface warming. Additional surface heating over the Arctic is imposed to the reference climates in which the stationary waves are located at different latitude bands. When the stationary waves are positioned at lower latitudes, the eddy driven jet is located at higher latitude, closer to the prescribed Arctic heating. As baroclinicity is more effectively perturbed, the jet shifts more equatorward that accompanies a larger reduction in the poleward eddy transport of heat and momentum. A stronger eddy-induced descending motion creates greater warming over the Arctic. Our study calls for a more accurate simulation of the present-day stationary wave pattern to enhance the predictability of the Arctic warming response in a changing climate.

  14. Hadron beams and accelerators

    International Nuclear Information System (INIS)

    Roser, T.

    1994-01-01

    There were four sessions on Hadron Beams and Accelerators with 7 talks on Siberian Snakes and spin rotators, 3 talks on polarization build-up of unpolarized beams in storage rings and 5. 9, and 3 talks on low, medium, and high energy polarimeters, respectively. In this paper I will briefly describe a few highlights from these sessions, giving emphasis to topics which I think will play an important role in the future

  15. Step-by-step guide to building an inexpensive 3D printed motorized positioning stage for automated high-content screening microscopy.

    Science.gov (United States)

    Schneidereit, Dominik; Kraus, Larissa; Meier, Jochen C; Friedrich, Oliver; Gilbert, Daniel F

    2017-06-15

    High-content screening microscopy relies on automation infrastructure that is typically proprietary, non-customizable, costly and requires a high level of skill to use and maintain. The increasing availability of rapid prototyping technology makes it possible to quickly engineer alternatives to conventional automation infrastructure that are low-cost and user-friendly. Here, we describe a 3D printed inexpensive open source and scalable motorized positioning stage for automated high-content screening microscopy and provide detailed step-by-step instructions to re-building the device, including a comprehensive parts list, 3D design files in STEP (Standard for the Exchange of Product model data) and STL (Standard Tessellation Language) format, electronic circuits and wiring diagrams as well as software code. System assembly including 3D printing requires approx. 30h. The fully assembled device is light-weight (1.1kg), small (33×20×8cm) and extremely low-cost (approx. EUR 250). We describe positioning characteristics of the stage, including spatial resolution, accuracy and repeatability, compare imaging data generated with our device to data obtained using a commercially available microplate reader, demonstrate its suitability to high-content microscopy in 96-well high-throughput screening format and validate its applicability to automated functional Cl - - and Ca 2+ -imaging with recombinant HEK293 cells as a model system. A time-lapse video of the stage during operation and as part of a custom assembled screening robot can be found at https://vimeo.com/158813199. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Automation of Aditya tokamak plasma position control DC power supply

    Energy Technology Data Exchange (ETDEWEB)

    Arambhadiya, Bharat, E-mail: bharat@ipr.res.in; Raj, Harshita; Tanna, R.L.; Edappala, Praveenlal; Rajpal, Rachana; Ghosh, Joydeep; Chattopadhyay, P.K.; Kalal, M.B.

    2016-11-15

    Highlights: • Plasma position control is very essential for obtaining repeatable high temperature, high-density discharges of longer durations in tokomak. • The present capacitor bank has limitations of maximum current capacity and position control beyond 200 ms. • The installation of a separate set of coils and a DC power supply can control the plasma position beyond 200 ms. • A high power thyristor (T588N1200) triggers for DC current pulse of 300 A fires precisely at required positions to modify plasma position. • The commissioning is done for the automated in-house, quick and reliable solution. - Abstract: Plasma position control is essential for obtaining repeatable high temperature, high-density discharges of longer duration in tokamaks. Recently, a set of external coils is installed in the vertical field mode configuration to control the radial plasma position in ADITYA tokamak. The existing capacitor bank cannot provide the required current pulse beyond 200 ms for position control. This motivated to have a DC power supply of 500 A to provide current pulse beyond 200 ms for the position control. The automatization of the DC power supply mandated interfaces with the plasma control system, Aditya Pulse Power supply, and Data acquisition system for coordinated discharge operation. A high current thyristor circuit and a timer circuit have been developed for controlling the power supply automatically for charging vertical field coils of Aditya tokamak. Key protection interlocks implemented in the development ensure machine and occupational safety. Fiber-optic trans-receiver isolates the power supply with other subsystems, while analog channel is optically isolated. Commissioning and testing established proper synchronization of the power supply with tokamak operation. The paper discusses the automation of the DC power supply with main circuit components, timing control, and testing results.

  17. GINA--a polarized neutron reflectometer at the Budapest Neutron Centre.

    Science.gov (United States)

    Bottyán, L; Merkel, D G; Nagy, B; Füzi, J; Sajti, Sz; Deák, L; Endrőczi, G; Petrenko, A V; Major, J

    2013-01-01

    The setup, capabilities, and operation parameters of the neutron reflectometer GINA, the recently installed "Grazing Incidence Neutron Apparatus" at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 Å are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by a five-element pyrolytic graphite monochromator, the reflected intensity from a 20 × 20 mm(2) sample has been doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes, and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3 × 10(-5) have been measured by the instrument. The instrument capabilities are demonstrated by a non-polarized and a polarized reflectivity experiment on a Si wafer and on a magnetic film of [(62)Ni/(nat)Ni](5) isotope-periodic layer composition. The facility is now open for the international user community. Its further development is underway establishing new sample environment options and spin analysis of off-specularly scattered radiation as well as further decreasing the background.

  18. GINA-A polarized neutron reflectometer at the Budapest Neutron Centre

    Energy Technology Data Exchange (ETDEWEB)

    Bottyan, L.; Merkel, D. G.; Nagy, B.; Sajti, Sz.; Deak, L.; Endroczi, G. [Wigner RCP, RMKI, H-1525 Budapest, P.O. Box 49 (Hungary); Fuezi, J. [Wigner RCP, SZFKI, H-1525 Budapest, P.O. Box 49 (Hungary); University of Pecs, Pollack Mihaly Faculty of Engineering and Information Technology, H-7602 Pecs, P.O. Box 219 (Hungary); Petrenko, A. V. [Frank Laboratory of Neutron Physics, JINR, Joliot-Curie 6, Dubna, 141980 (Russian Federation); Major, J. [Wigner RCP, RMKI, H-1525 Budapest, P.O. Box 49 (Hungary); Max-Planck-Institut fuer Intelligente Systeme (formerly Max-Planck-Institut fuer Metallforschung), Heisenbergstr. 3, D-70569 Stuttgart (Germany)

    2013-01-15

    The setup, capabilities, and operation parameters of the neutron reflectometer GINA, the recently installed 'Grazing Incidence Neutron Apparatus' at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 A are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by a five-element pyrolytic graphite monochromator, the reflected intensity from a 20 Multiplication-Sign 20 mm{sup 2} sample has been doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes, and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3 Multiplication-Sign 10{sup -5} have been measured by the instrument. The instrument capabilities are demonstrated by a non-polarized and a polarized reflectivity experiment on a Si wafer and on a magnetic film of [{sup 62}Ni/{sup nat}Ni]{sub 5} isotope-periodic layer composition. The facility is now open for the international user community. Its further development is underway establishing new sample environment options and spin analysis of off-specularly scattered radiation as well as further decreasing the background.

  19. Study of generalized parton distributions and deeply virtual Compton scattering on the nucleon with the CLAS and CLAS12 detectors at the Jefferson Laboratory (Virginia, US)

    International Nuclear Information System (INIS)

    Guegan, B.

    2012-11-01

    The Generalized Parton Distributions (GPDs) provide a new description of the nucleon structure in terms of its elementary constituents, the quarks and the gluons. The GPDs give access to a unified picture of the nucleon, correlating the information obtained from the measurements of the Form Factors and the Parton Distribution Functions. They describe the correlation between the transverse position and the longitudinal momentum fraction of the partons in the nucleon. Deeply Virtual Compton Scattering (DVCS), the electroproduction of a real photon on a single quark of the nucleon eN → e'N'γ, is the most straightforward exclusive process allowing access to the GPDs. A dedicated experiment to study DVCS with the CLAS detector of Jefferson Lab has been carried out using a 5.883 GeV polarized electron beam and an unpolarized hydrogen target, allowing to collect DVCS events in the widest kinematic range ever explored in the valence region: 1 2 2 , 0.1 B 2 . In this work, we present the extraction of three different DVCS observables: the unpolarized cross section, the difference of polarized cross sections and the beam spin asymmetry. We present comparisons with GPD model. We show a preliminary extraction of the GPDs using the latest fitting code procedure on our data, and a preliminary interpretation of the results in terms of parton density. (author)

  20. Deeply virtual compton scattering on the nucleon with the Clas Detector of Jefferson Lab: measurement of the polarized and unpolarized cross sections; Etude de la diffusion compton profondement virtuelle sur le nucleon avec le detecteur Clas de Jefferson Lab: mesure des sections efficaces polarisees et non polarisees

    Energy Technology Data Exchange (ETDEWEB)

    Jo, H.S

    2007-03-15

    The Generalized Parton Distributions (GPDs), introduced in the 1990's, provide the most complete description of the structure (in quarks and gluons) of the nucleon. The Deeply Virtual Compton Scattering (DVCS), which corresponds to the 'hard' exclusive electroproduction of photons on the nucleon, is a key process among the reactions allowing access to the GPDs. A DVCS-dedicated experiment was carried out in 2005 with the CLAS detector of Jefferson Lab, using a polarized electron beam of 5.776 GeV and a hydrogen target. For this experiment, we built and used a dedicated electromagnetic calorimeter capable of detecting the final-state photon. The collected data allowed us to study the DVCS in the widest kinematic range ever accessed for this reaction: 1 < Q{sup 2} < 4.6 GeV{sup 2}, 0.1 < x{sub B} < 0.58, 0.09 < -t < 2 GeV{sup 2}. The work performed during this PhD includes simulation work done for the preparation of the experiment, timing calibration of one of the CLAS subsystems, and data analysis. The aim of the data analysis was the extraction of the unpolarized cross sections of the studied reaction and of the difference of the polarized cross sections, this latter observable being linearly proportional to the GPDs. The obtained results were compared to DVCS theoretical calculations based on one of the most up-to-date GPD parametrizations. (author)

  1. Development of a highly sensitive current and position monitor with HTS squids and an HTS magnetic shield

    International Nuclear Information System (INIS)

    Watanabe, T.; Ikeda, T.; Kase, M.; Yano, Y.; Watanabe, S.; Sasaki, Y.; Kawaguchi, T.

    2005-01-01

    A highly sensitive current and position monitor with HTS (High-Temperature Superconducting) SQUIDs (Superconducting QUantum Interference Device) and an HTS magnetic shield for the measurement of the intensity of faint beams, such as a radioisotope beam, has been developed for the RIKEN RI beam factory project. The HTS magnetic shield and the HTS current sensor including the HTS SQUID are cooled by a low-vibration pulse-tube refrigerator. Both the HTS magnetic shield and the HTS current sensor were fabricated by dip-coating a thin Bi 2 -Sr 2 -Ca 2 -Cu 3 -O x (Bi-2223) layer on 99.9% MgO ceramic substrates. The HTS technology enables us to develop a system equipped with a downsized and highly sensitive current monitor. Recently, a prototype system was completed and installed in the beam transport line of the RIKEN Ring Cyclotron to measure the DC-current of high-energy heavy-ion beams. As a result, we succeeded in measuring the intensity of the 600 nA 40 Ar 17+ beam (95 MeV/u). We describe the present status of the monitor system and the results of the beam measurements. (author)

  2. The Effects of L2C Signal Tracking on High-Precision Carrier Phase GPS Positioning

    Science.gov (United States)

    Berglund, H.; Blume, F.; Estey, L. H.; Borsa, A. A.

    2010-12-01

    In 2005, the L2C signal was introduced to improve the accuracy, tracking and redundancy of the GPS system for civilian users. The L2C signal also provides improved SNR data when compared with the L2P(Y) legacy signal, comparable to that of the L1 C/A-code, which allows for better tracking at lower elevations. With the recent launch of the first block II-F satellite (SVN62/PRN25), there are 8 healthy satellites broadcasting L2C signals, or 25% of the constellation. However, GNSS network operators such as the UNAVCO Plate Boundary Observatory (PBO) have been hesitant to use the new signal as it is not well determined how tracking and logging L2C could affect the positions derived from L2 carrier phase measurements for a given receiver. The L2C carrier phase is in quadrature (90° out of phase) with the L2P(Y) phase that has been used by high-precision positioning software since the beginning of GPS. To complicate matters further, some receiver manufacturers (e.g. Trimble) correct for this when logging L2C phase while others (e.g. Topcon) do not. The L2C capability of receivers currently in widespread use in permanent networks can depend on firmware as well as hardware; in some cases receivers can simultaneously track L2C and L2P(Y) phases and some can track only one or the other, and the resulting observation files can depend on how individual operators configure the devices. In cases where both L2C and L2P(Y) are logged simultaneously, translation software (such as UNAVCO’s teqc) must be used carefully in order to select which L2 observation is written to RINEX (2.11) and used in positioning. Modifications were recently made to teqc to eliminate potential confusion in that part of the process; if L2C code observations appear in a RINEX (2.11) file produced by teqc, the L2 phase and S2 SNR observations were from the L2C carrier for those satellites. To date L2C analyses have been restricted to special applications such as snow depth and soil moisture using SNR data

  3. Ranking low, feeling high: How hierarchical position and experienced power promote prosocial behavior in response to procedural justice.

    Science.gov (United States)

    van Dijke, Marius; De Cremer, David; Langendijk, Gerben; Anderson, Cameron

    2018-02-01

    Research shows that power can lead to prosocial behavior by facilitating the behavioral expression of dispositional prosocial motivation. However, it is not clear how power may facilitate responses to contextual factors that promote prosocial motivation. Integrating fairness heuristic theory and the situated focus theory of power, we argue that in particular, organization members in lower (vs. higher) hierarchical positions who simultaneously experience a high (vs. low) sense of power respond with prosocial behavior to 1 important antecedent of prosocial motivation, that is, the enactment of procedural justice. The results from a multisource survey among employees and their leaders from various organizations (Study 1) and an experiment using a public goods dilemma (Study 2) support this prediction. Three subsequent experiments (Studies 3-5) show that this effect is mediated by perceptions of authority trustworthiness. Taken together, this research (a) helps resolve the debate regarding whether power promotes or undermines prosocial behavior, (b) demonstrates that hierarchical position and the sense of power can have very different effects on processes that are vital to the functioning of an organization, and (c) helps solve ambiguity regarding the roles of hierarchical position and power in fairness heuristic theory. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. Ozone-induced dissociation on a traveling wave high-resolution mass spectrometer for determination of double-bond position in lipids.

    Science.gov (United States)

    Vu, Ngoc; Brown, Jeffery; Giles, Kevin; Zhang, Qibin

    2017-09-15

    The position of C=C within fatty acyl chains affects the biological function of lipids. Ozone-induced dissociation mass spectrometry (OzID-MS) has great potential in determination of lipid double-bond position, but has generally been implemented on low-resolution ion trap mass spectrometers. In addition, most of the OzID-MS experiments carried out so far were focused on the sodiated adducts of lipids; fragmentation of the most commonly observed protonated ions generated in LC/MS-based lipidomics workflow has been less explored. Ozone generated in line from an ozone generator was connected to the trap and transfer gas supply line of a Synapt G2 high-resolution mass spectrometer. Protonated ions of different phosphatidylcholines (PC) were generated by electrospray ionization through direct infusion. Different parameters, including traveling wave height and velocity, trap entrance and DC potential, were adjusted to maximize the OzID efficiency. sn-positional isomers and cis/trans isomers of lipids were compared for their reactivity with ozone. Traveling wave height and velocity were tuned to prolong the encounter time between lipid ions and ozone, and resulted in improved OzID efficiency, as did increasing trapping region DC and entrance potential. Under optimized settings, at least 1000 times enhancement in OzID efficiency was achieved compared to that under default settings for monounsaturated PC standards. Monounsaturated C=C in the sn-2 PC isomer reacted faster with ozone than the sn-1 isomer. Similarly, the C=C in trans PC reacted faster than in cis PC. This is the first implementation of OzID in the trap and transfer region of a traveling wave enabled high-resolution mass spectrometer. The OzID reaction efficiency is significantly improved by slowing down ions in the trap region for their prolonged interaction with ozone. This will facilitate application of high-resolution OzID-MS in lipidomics. Copyright © 2017 John Wiley & Sons, Ltd.

  5. The Effects of a Positive Mindset Trigger Word Pre-Performance Routine on the Expressive Performance of Junior High Age Singers

    Science.gov (United States)

    Broomhead, Paul; Skidmore, Jon B.; Eggett, Dennis L.; Mills, Melissa M.

    2012-01-01

    The effects of a positive mindset trigger word intervention on the expressive performance of individual junior high singers were tested in this study. Participants (N = 155) were assigned randomly to a control group or an experimental group. Members of the experimental group participated in a 40-min intervention while members of the control group…

  6. Spin-filtering junctions with double ferroelectric barriers

    International Nuclear Information System (INIS)

    Yan, Ju; Ding-Yu, Xing

    2009-01-01

    An FS/FE/NS/FE/FS double tunnel junction is suggested to have the ability to inject, modulate and detect the spin-polarized current electrically in a single device, where FS is the ferromagnetic semiconductor electrode, NS is the nonmagnetic semiconductor, and FE the ferroelectric barrier. The spin polarization of the current injected into the NS region can be switched between a highly spin-polarized state and a spin unpolarized state. The high spin polarization may be detected by measuring the tunneling magnetoresistance ratio of the double tunnel junction

  7. Investigation of the Pygmy Dipole Resonance in {sup 60}Ni

    Energy Technology Data Exchange (ETDEWEB)

    Fritzsche, Matthias; Pietralla, Norbert; Romig, Christopher; Savran, Deniz; Sonnabend, Kerstin [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner; Weller, Henry R. [Triangle Universities Nuclear Laboratory, Duke University, Durham, NC (United States); Zilges, Andreas [Institut fuer Kernphysik, Universitaet Koeln (Germany)

    2009-07-01

    At the High Intensity Photon Setup (HIPS) at S-DALINAC in Darmstadt {sup 60}Ni was investigated with unpolarized bremsstrahlung with energies up to 8.0 MeV and 9.9 MeV, respectively. Determination of spin and parity quantum numbers and absolute transition strengths was possible, using HPGe detectors placed under different angles. To assign also parity quantum numbers, the polarized photon beam of the High Intensity Gamma Source (HI{gamma}S) at Duke University was used. With the combined results, evidence of the Pygmy Dipole Resonance in {sup 60}Ni was found.

  8. [Research in elementary particles and interactions

    International Nuclear Information System (INIS)

    Adair, R.; Sandweiss, J.; Schmidt, M.

    1992-05-01

    Research of the Yale University groups in the areas of elementary particles and their interactions are outlined. Work on the following topics is reported: development of CDF trigger system; SSC detector development; study of heavy flavors at TPL; search for composite objects produced in relativistic heavy-ion collisions; high-energy polarized lepton-nucleon scattering; rare K + decays; unpolarized high-energy muon scattering; muon anomalous magnetic moment; theoretical high-energy physics including gauge theories, symmetry breaking, string theory, and gravitation theory; study of e + e - interactions with the SLD detector at SLAC; and the production and decay of particles containing charm and beauty quarks

  9. Subsets of Women With Close or Positive Margins After Breast-Conserving Surgery With High Local Recurrence Risk Despite Breast Plus Boost Radiotherapy

    International Nuclear Information System (INIS)

    Lupe, Krystine; Truong, Pauline T.; Alexander, Cheryl; Lesperance, Mary; Speers, Caroline; Tyldesley, Scott

    2011-01-01

    Purpose: (1) To examine the effect of surgical margin status on local recurrence (LR) and survival following breast-conserving therapy; (2) To identify subsets with close or positive margins with high LR risk despite whole breast radiotherapy (RT) plus boost. Methods and Materials: Subjects were 2,264 women with pT1–3, any N, M0 invasive breast cancer, treated with breast-conserving surgery and whole breast ± boost RT. Five-year Kaplan-Meier (KM) LR, breast cancer–specific and overall survival (BCSS and OS) were compared between cohorts with negative (n = 1,980), close (n = 222), and positive (n = 62) margins. LR rates were analyzed according to clinicopathologic characteristics. Multivariable Cox regression modeling and matched analysis of close/positive margin cases and negative margin controls were performed. Results: Median follow-up was 5.2 years. Boost RT was used in 92% of patients with close or positive margins. Five-year KM LR rates in the negative, close and positive margin cohorts were 1.3%, 4.0%, and 5.2%, respectively (p = 0.001). BCSS and OS were similar in the three margin subgroups. In the close/positive margin cohort, LR rates were 10.2% with age 10% despite whole breast plus boost RT. These patients should be considered for more definitive surgery.

  10. Family Caregivers' Patterns of Positive and Negative Affect

    Science.gov (United States)

    Robertson, Suzanne M.; Zarit, Steven H.; Duncan, Larissa G.; Rovine, Michael J.; Femia, Elia E.

    2007-01-01

    Stressful and positive family caregiving experiences were examined as predictors of caregivers' patterns of positive and negative affect in a sample of families providing care for a relative with dementia (N = 234). Four affect pattern groups were identified: (a) Well Adjusted (i.e., high positive affect, low negative affect); (b) Ambiguous (i.e.,…

  11. High frequency of multiresistant coagulase-positive Staphylococcus aureus found in slaughter pigs in Uruguay.

    Science.gov (United States)

    Meyer, Cornelia; Fredriksson-Ahomaa, Maria; Stüber, Elisabeth; Thiel, Susanne; Märtlbauer, Erwin

    2012-01-01

    Staphylococcus aureus are a hazard to human health since they can cause infections and food poisoning. Antimicrobial resistant strains render the treatment of infections problematic and contribute to the spread of antimicrobial resistance. They are therefore of great public concern. This study determined the resistance pattern of coagulase-positive S. aureus (CPSA) isolated from nasal swabs of 100 slaughter pigs from one farm in Uruguay. Out of 69 animals, 71 CPSA were collected. Minimum inhibitory concentrations of 20 antimicrobials were determined using the broth microdilution method in accordance with CLSI recommendations. No methicillin-resistant S. aureus were detected. All CPSA were resistant to three or more classes of antimicrobials (i.e., multiresistant), whereby all CPSA were resistant to spectinomycin. Most of the isolates (46%) were resistant to six classes of antimicrobials. Almost all isolates were resistant to penicillin (99%), ampicillin (99%), gentamicin (96%), tetracycline (90%), and tilmicosin (87%). Very high resistance rates were observed against erythromycin (77%) and clindamycin (70%). High resistance was observed against tiamulin (40%), enrofloxacin (31%), and florfenicol (23%) and low resistance was observed against amoxicillin/clavulanic acid (4%). All CPSA isolates were mecA negative. The results of the present study could be related to an overuse of antimicrobials in pig production and should encourage veterinarians and pig holders to practice a controlled administration of chemotherapeutics in pig husbandry.

  12. A statistical assessment of zero-polarization catalogues

    Science.gov (United States)

    Clarke, D.; Naghizadeh-Khouei, J.; Simmons, J. F. L.; Stewart, B. G.

    1993-03-01

    The statistical behavior associated with polarization measurements is presented. The cumulative distribution function for measurements of unpolarized sources normalized by the measurement error is considered and Kolmogorov tests have been applied to data which might be considered as being representative of assemblies of unpolarized stars. Tinbergen's (1979, 1982) and Piirola's I (1977) catalogs have been examined and reveal shortcomings, the former indicating the presence of uncorrected instrumental polarization in part of the data and both suggesting that the quoted errors are in general slightly underestimated. Citings of these catalogs as providing evidence that middle-type stars in general exhibit weak intrinsic polarizations are shown to be invalid.

  13. High-accuracy local positioning network for the alignment of the Mu2e experiment.

    Energy Technology Data Exchange (ETDEWEB)

    Hejdukova, Jana B. [Czech Technical Univ., Prague (Czech Republic)

    2017-06-01

    This Diploma thesis describes the establishment of a high-precision local positioning network and accelerator alignment for the Mu2e physics experiment. The process of establishing new network consists of few steps: design of the network, pre-analysis, installation works, measurements of the network and making adjustments. Adjustments were performed using two approaches. First is a geodetic approach of taking into account the Earth’s curvature and the metrological approach of a pure 3D Cartesian system on the other side. The comparison of those two approaches is performed and evaluated in the results and compared with expected differences. The effect of the Earth’s curvature was found to be significant for this kind of network and should not be neglected. The measurements were obtained with Absolute Tracker AT401, leveling instrument Leica DNA03 and gyrotheodolite DMT Gyromat 2000. The coordinates of the points of the reference network were determined by the Least Square Meth od and the overall view is attached as Annexes.

  14. Socioeconomic position and participation in colorectal cancer screening

    DEFF Research Database (Denmark)

    Frederiksen, B L; Jørgensen, Torben; Brasso, K

    2010-01-01

    Colorectal cancer (CRC) screening with faecal occult blood test (FOBT) has the potential to reduce the incidence and mortality of CRC. Screening uptake is known to be inferior in people with low socioeconomic position (SEP) when compared with those with high position; however, the results of most...... information on education, employment, and income to encompass different but related aspects of socioeconomic stratification. Also, the impact of ethnicity and cohabiting status was analysed.......Colorectal cancer (CRC) screening with faecal occult blood test (FOBT) has the potential to reduce the incidence and mortality of CRC. Screening uptake is known to be inferior in people with low socioeconomic position (SEP) when compared with those with high position; however, the results of most...... previous studies have limited value because they are based on recall or area-based measures of socioeconomic position, and might thus be subject to selective participation and misclassification. In this study we investigated differences in CRC screening participation using register-based individual...

  15. Using high resolution aridity and drainage position data to better predict rainfall-runoff relationships in complex upland topography

    Science.gov (United States)

    Metzen, D.; Sheridan, G. J.; Benyon, R. G.; Lane, P. N. J.

    2015-12-01

    In topographically complex terrain, the interaction of aspect-dependent solar exposure and drainage-position-dependent flow accumulation results in energy and water partitioning that is highly spatially variable. Catchment scale rainfall-runoff relationships are dependent on these smaller scale spatial patterns. However, there remains considerable uncertainty as to how to represent this smaller scale variability within lumped parameter, catchment scale rainfall-runoff models. In this study we aim to measure and represent the key interactions between aridity and drainage position in complex terrain to inform the development of simple catchment-scale hydrologic model parameters. Six measurement plots were setup on opposing slopes in an east-west facing eucalypt forest headwater catchment. The field sites are spanning three drainage positions with two contrasting aridity indices each, while minimizing variations in other factors, e.g. geology and weather patterns. Sapflow, soil water content (SWC) and throughfall were continuously monitored on two convergent hillslopes with similar size (1.3 and 1.6ha) but contrasting aspects (north and south). Soil depth varied from 0.6m at the topslope to >2m at the bottomslope positions. Maximum tree heights ranged from 16.2m to 36.9m on the equator-facing slope and from 30.1m to 45.5m on the pole-facing slope, with height decreasing upslope on both aspects. Two evapotranspiration (ET) patterns emerged in relation to aridity and drainage position. On the equator-facing slope (AI~ 2.1), seasonal understorey and overstorey ET patterns were in sync, whereas on the pole-facing slope (AI~1.5) understorey ET showed larger seasonal fluctuations than overstorey ET. Seasonal ET patterns and competition between soil evaporation and root water uptake lead to distinct differences in profile SWC across the sites, likely caused by depletion from different depths. Topsoil water content on equator-facing slopes was generally lower and responded

  16. 5th International Symposium on Positive Systems

    CERN Document Server

    Farina, Lorenzo; Setola, Roberto; Germani, Alfredo

    2017-01-01

    This book presents high-quality original contributions on positive systems, including topics such as: monotone dynamical systems in mathematical biology and game theory; mathematical developments for networked systems in biology, chemistry and the social sciences; linear and nonlinear positive operators; dynamical analysis, observation and control of positive distributed parameter systems; stochastic realization theory; biological systems with positive variables and positive controls; iterated function systems; nonnegative dynamic processes; and dimensioning problems for collaborative systems. The book comprises a selection of the best papers presented at the POSTA 2016, the 5th International Symposium on Positive Systems, which was held in Rome, Italy, in September 2016. This conference series represents a targeted response to the growing need for research that reports on and critically discusses a wide range of topics concerning the theory and applications of positive systems.

  17. Communication-based positioning systems: past, present and prospects

    International Nuclear Information System (INIS)

    Ma Guanyi; Wan Qingtao; Gan Tong

    2012-01-01

    This paper reviews positioning systems in the context of communication systems. First, the basic positioning technique is described for location based service (LBS) in mobile communication systems. Then the high integrity global positioning system (iGPS) is introduced in terms of aspects of what it is and how the low Earth orbit (LEO) Iridium telecommunication satellites enhance the global positioning system (GPS). Emphasis is on the Chinese Area Positioning System (CAPS) which is mainly based on commercial geostationary (GEO) communication satellites, including decommissioned GEO and inclined geosynchronous communication satellites. Characterized by its low cost, high flexibility, wide-area coverage and ample frequency resources, a distinctive feature of CAPS is that its navigation messages are generated on the ground, then uploaded to and forwarded by the communication satellites. Fundamental principles and key technologies applied in the construction of CAPS are presented in detail from the CAPS validation phase to its experimental system setup. A prospective view of CAPS has concluded it to be a seamless, high accuracy, large capacity navigation and communication system which can be achieved by expanding it world wide and enhancing it with LEO satellites and mobile base stations. Hence, this system is a potential candidate for the next generation of radio navigation after GPS. (invited reviews)

  18. The High Five: Associations of the Five Positive Factors with the Big Five and Well-being

    Directory of Open Access Journals (Sweden)

    Alejandro C. Cosentino

    2017-07-01

    Full Text Available The study of individual differences in positive characteristics has mainly focused on moral traits. The objectives of this research were to study individual differences in positive characteristics from the point of view of the layperson, including non-moral individual characteristics, and to generate a replicable model of positive factors. Three studies based on a lexical approach were conducted. The first study generated a corpus of words which resulted in a refined list of socially shared positive characteristics. The second study produced a five-factor model of positive characteristics: erudition, peace, cheerfulness, honesty, and tenacity. The third study confirmed the model with a different sample. The five-positive-factor model not only showed positive associations with emotional, psychological and social well-being, but it also accounted for the variance beyond that accounted for by the Big Five factors in predicting these well-being dimensions. In addition, the presence of convergent and divergent validity of the five positive factors is shown with relation to the Values-in-Action (VIA classification of character strengths proposed by Peterson and Seligman (2004.

  19. Hybrid integrated sensor for position measurement

    International Nuclear Information System (INIS)

    Schmidt, B.; Schott, H.; Just, H.-J.

    1986-01-01

    The design, fabrication and performance of an integrated two-dimensional position sensitive photodetector are presented. The optoelectronic device used as sensitive element in the circuit is a full area position sensitive photodiode (PPD) with high linearity over the full sensitive area. The PPD is integrated with the analog electronics in a hybrid circuit using thick film technology. The analog electronics includes the signal amplification and the signal conditioning to form the output signals proportional to the light beam center position at the sensor surface and an output signal proportional to the light beam intensity. Using hybrid integration a new position sensitive transducer is developed giving output signals, transmiting in large distances without problems and driving directly actuators in any control system

  20. Daily fluctuations in positive affect positively co-vary with working memory performance.

    Science.gov (United States)

    Brose, Annette; Lövdén, Martin; Schmiedek, Florian

    2014-02-01

    Positive affect is related to cognitive performance in multiple ways. It is associated with motivational aspects of performance, affective states capture attention, and information processing modes are a function of affect. In this study, we examined whether these links are relevant within individuals across time when they experience minor ups and downs of positive affect and work on cognitive tasks in the laboratory on a day-to-day basis. Using a microlongitudinal design, 101 younger adults (20-31 years of age) worked on 3 working memory tasks on about 100 occasions. Every day, they also reported on their momentary affect and their motivation to work on the tasks. In 2 of the 3 tasks, performance was enhanced on days when positive affect was above average. This performance enhancement was also associated with more motivation. Importantly, increases in task performance on days with above-average positive affect were mainly unrelated to variations in negative affect. This study's results are in line with between-person findings suggesting that high levels of well-being are associated with successful outcomes. They imply that success on cognitively demanding tasks is more likely on days when feeling happier. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  1. A novel method for estimating the initial rotor position of PM motors without the position sensor

    International Nuclear Information System (INIS)

    Rostami, Alireza; Asaei, Behzad

    2009-01-01

    Permanent magnet (PM) motors have been used widely in the industrial applications. However, a need of the position sensor is a drawback of their control system. The sensorless methods using the back-EMF (electromotive force) cannot detect the rotor position at a standstill; recently, a few methods proposed to detect the initial rotor position, but they have high estimation error which reduces starting torque of the motor. Therefore, in this paper, a novel method to detect the initial rotor position of the PM motors is proposed, first, by using a space vector model, response of the stator current space vector to the saturation of the stator core is analyzed; then a novel method based on the saturation effect is presented that estimates the initial rotor position and the maximum estimation error is less than 3.8 deg. Simulation results confirm this method is effective and precise, and variation of the motor parameters does not affect its precision.

  2. A novel method for estimating the initial rotor position of PM motors without the position sensor

    Energy Technology Data Exchange (ETDEWEB)

    Rostami, Alireza; Asaei, Behzad [School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, Tehran (Iran)

    2009-08-15

    Permanent magnet (PM) motors have been used widely in the industrial applications. However, a need of the position sensor is a drawback of their control system. The sensorless methods using the back-EMF (electromotive force) cannot detect the rotor position at a standstill; recently, a few methods proposed to detect the initial rotor position, but they have high estimation error which reduces starting torque of the motor. Therefore, in this paper, a novel method to detect the initial rotor position of the PM motors is proposed, first, by using a space vector model, response of the stator current space vector to the saturation of the stator core is analyzed; then a novel method based on the saturation effect is presented that estimates the initial rotor position and the maximum estimation error is less than 3.8. Simulation results confirm this method is effective and precise, and variation of the motor parameters does not affect its precision. (author)

  3. Development of polarized {sup 3}He filter for polarized neutron experiment

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, K.; Sato, H.; Yoshimi, A.; Asahi, K. [Tokyo Inst. of Tech. (Japan). Faculty of Science; Masuda, Y.; Muto, S.; Ishimoto, S.; Morimoto, K.

    1996-08-01

    A high-pressure polarized {sup 3}He gas cell, pumped with two diode lasers, has been developed at KEK for use as a polarizer and a spin analyzer for low energy neutrons. The polarization attained of {sup 3}He was determined through the measurement of the transmission of the unpolarized neutrons through the {sup 3}He cell. So far we obtained P{sub He}=18% at 10 atm and P{sub He}=12% at 20 atm. (author)

  4. Hadron beams and accelerators

    International Nuclear Information System (INIS)

    Roser, T.

    1995-01-01

    There were four sessions on Hadron Beams and Accelerators with 7 talks on Siberian Snakes and spin rotators, 3 talks on polarization build-up of unpolarized beams in storage rings and 5, 9, and 3 talks on low, medium, and high energy polarimeters, respectively. In this paper I will briefly describe a few highlights from these sessions, giving emphasis to topics which I think will play an important role in the future. copyright 1995 American Institute of Physics

  5. High sensitivity optical measurement of skin gloss.

    Science.gov (United States)

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F; Urbach, H Paul; Varghese, Babu

    2017-09-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the improved sensitivity of the two proposed methods using Monte Carlo simulations and experiments performed on ISO gloss calibration standards with an optical prototype. The performance and linearity of the method was compared with different professional gloss measurement devices based on the ratio of specular to diffuse intensity. We demonstrate the feasibility for in-vivo skin gloss measurements by quantifying the temporal evolution of skin gloss after application of standard paraffin cream bases on skin. The presented method opens new possibilities in the fields of cosmetology and dermatopharmacology for measuring the skin gloss and resorption kinetics and the pharmacodynamics of various external agents.

  6. High-Temperature Creep Behaviour and Positive Effect on Straightening Deformation of Q345c Continuous Casting Slab

    Science.gov (United States)

    Guo, Long; Zhang, Xingzhong

    2018-03-01

    Mechanical and creep properties of Q345c continuous casting slab subjected to uniaxial tensile tests at high temperature were considered in this paper. The minimum creep strain rate and creep rupture life equations whose parameters are calculated by inverse-estimation using the regression analysis were derived based on experimental data. The minimum creep strain rate under constant stress increases with the increase of the temperature from 1000 °C to 1200 °C. A new casting machine curve with the aim of fully using high-temperature creep behaviour is proposed in this paper. The basic arc segment is cancelled in the new curve so that length of the straightening area can be extended and time of creep behaviour can be increased significantly. For the new casting machine curve, the maximum straightening strain rate at the slab surface is less than the minimum creep strain rate. So slab straightening deformation based on the steel creep behaviour at high temperature can be carried out in the process of Q345c steel continuous casting. The effect of creep property at high temperature on slab straightening deformation is positive. It is helpful for the design of new casting machine and improvement of old casting machine.

  7. Does Positivity Operate When the Stakes are High?: Health Status and Decision-Making Among Older Adults

    Science.gov (United States)

    English, Tammy; Carstensen, Laura L.

    2015-01-01

    Research and theory suggest that emotional goals are increasingly prioritized with age. Related empirical work has shown that, compared to younger adults, older adults attend to and remember positive information more than negative information. This age-related positivity effect has been eliminated in experiments that have explicitly demanded processing of both positive and negative information. In the present study, we explored whether a reduction of the preference for positive information over negative information appears when the material being reviewed holds personal relevance for the individual. Older participants whose health varied from poor to very good reviewed written material prior to making decisions about health related and non-health related issues. As predicted, older adults in relatively poor health (compared with those in relatively good health) showed less positivity in review of information while making health-related decisions. In contrast, positivity emerged regardless of health status for decisions that were unrelated to health. Across decision contexts, those individuals who focused more on positive information than negative information reported better post-decisional mood and greater decision satisfaction. Results are consistent with the theoretical argument that the age-related positivity effect reflects goal-directed cognitive processing and, furthermore, suggests that personal relevance and contextual factors determine whether or not positivity emerges. PMID:25894484

  8. Positional Match Running Performance in Elite Gaelic Football.

    Science.gov (United States)

    Malone, Shane; Solan, Barry; Collins, Kieran D; Doran, Dominic A

    2016-08-01

    Malone, S, Solan, B, Collins, KD, and Doran, DA. Positional match running performance in elite Gaelic football. J Strength Cond Res 30(8): 2292-2298, 2016-There is currently limited information available on match running performance in Gaelic football. The objective of the current study was to report on the match running profile of elite male Gaelic football and assess positional running performance. In this observational study, 50 elite male Gaelic football players wore 4-Hz global positioning systems units (VX Sports) across 30 competitive games with a total of 215 full game data sets collected. Activity was classed according to total distance, high-speed distance (≥17 km·h), sprint distance (≥22 km·h), mean velocity (km·h), peak velocity (km·h), and number of accelerations. The average match distance was 8,160 ± 1,482 m, reflective of a relative distance of 116 ± 21 m·min, with 1,731 ± 659 m covered at high speed, which is reflective of a relative high-speed distance of 25 ± 9 m·min. The observed sprint distance was 445 ± 169 m distributed across 44 sprint actions. The peak velocity was 30.3 ± 1.8 km·h with a mean velocity of 6.5 ± 1.2 km·h. Players completed 184 ± 40 accelerations, which represent 2.6 ± 0.5 accelerations per minute. There were significant differences between positional groups for both total running distance, high-speed running distance, and sprint distance, with midfielders covering more total and high-speed running distance, compared with other positions (p football match play.

  9. High Level of Tregs Is a Positive Prognostic Marker in Patients with HPV-Positive Oral and Oropharyngeal Squamous Cell Carcinomas

    Czech Academy of Sciences Publication Activity Database

    Lukešová, E.; Bouček, J.; Rotnáglová, E.; Salaková, M.; Koslabová, E.; Grega, M.; Eckschlager, T.; Říhová, Blanka; Procházka, B.; Klozar, J.; Tachezy, R.

    2014-01-01

    Roč. 2, č. 303929 (2014), 1-4 ISSN 2314-6141 R&D Projects: GA MZd(CZ) NT11542 Grant - others:GA UK(CZ) SVV 266513 Institutional support: RVO:61388971 Keywords : HPV positivity * Tregs * Infection Subject RIV: EE - Microbiology, Virology

  10. Comparative effectiveness of immediate antiretroviral therapy versus CD4-based initiation in HIV-positive individuals in high-income countries: observational cohort study

    NARCIS (Netherlands)

    Lodi, Sara; Phillips, Andrew; Logan, Roger; Olson, Ashley; Costagliola, Dominique; Abgrall, Sophie; van Sighem, Ard; Reiss, Peter; Miró, José M.; Ferrer, Elena; Justice, Amy; Gandhi, Neel; Bucher, Heiner C.; Furrer, Hansjakob; Moreno, Santiago; Monge, Susana; Touloumi, Giota; Pantazis, Nikos; Sterne, Jonathan; Young, Jessica G.; Meyer, Laurence; Seng, Rémonie; Dabis, Francois; Vandehende, Marie-Anne; Pérez-Hoyos, Santiago; Jarrín, Inma; Jose, Sophie; Sabin, Caroline; Hernán, Miguel A.; Ainsworth, J.; Anderson, J.; Babiker, A.; Delpech, V.; Dunn, D.; Easterbrook, P.; Fisher, M.; Gazzard, B.; Gilson, R.; Gompels, M.; Hill, T.; Johnson, M.; Leen, C.; Orkin, C.; Phillips, A.; Pillay, D.; Porter, K.; Sabin, C.; Walsh, J.; Glabay, A.; Thomas, R.; Jones, K.; Perry, N.; Pullin, A.; Churchill, D.; Bulbeck, S.; Mandalia, S.; Clarke, J.; Munshi, S.; Post, F.; Khan, Y.; Patel, P.; Karim, F.; Duffell, S.; Williams, I.; Dooley, D.; Schwenk, A.; Youle, M.; Lampe, F.; Chaloner, C.; Puradiredja, D. Ismajani; Bansi, L.; Weber, J.; Kemble, C.; Mackie, N.; Winston, A.; Wilson, A.; Bezemer, D. O.; Kesselring, A. M.; van Sighem, A. I.; Smit, C.; Zaheri, S.; Kortmann, W.; Prins, J. M.; Kuijpers, T. W.; Godfried, M. H.; Pajkrt, D.; Bos, J. C.; van der Valk, M.; Grijsen, M. L.; Wiersinga, W. J.; Vrouwe, Lieve; Brinkman, K.; Blok, W. L.; Ziekenhuis, Andreas; Veenstra, J.; Lettinga, K. D.; Mulder, J. W.; Lauw, F. N.; van Agtmael, M. A.; Perenboom, R. M.; Bomers, M.; Richter, C.; van der Berg, J. P.; Gisolf, E. H.; Schippers, E. F.; van Elzakker, E. P.; Bravenboer, B.; Kootstra, G. J.; Sprenger, H. G.; Doedens, R.; van Assen, S.; Gasthuis, Kennemer; Soetekouw, R.; Kroon, F. P.; van Dissel, J. T.; Arend, S. M.; Jolink, H.; Bauer, M. P.; Weijer, S.; Lowe, S.; Lashof, A. Oude; Posthouwer, D.; Koopmans, P. P.; Warris, A.; van Crevel, R.; Nouwen, J. L.; Nispen, M. H.; Verbon, A.; Hassing, R. J.; Hartwig, N. G.; Ziekenhuis, Maasstad; Pogany, K.; Ziekenhuis, Sint Elisabeth; Juttmann, J. R.; van Kasteren, M. E. E.; Mudrikova, T.; Ellerbroek, P. M.; Oosterheert, J. J.; Barth, R. E.; Kinderziekenhuis, Wilhelmina; Bont, L. J.; de Ruyter Ziekenhuis, Admiraal; Stegeman, A.; Alleman, M. A.; Bouwhuis, J. W.; Abgrall, S.; Barin, F.; Bentata, M.; Billaud, E.; Boué, F.; Burty, C.; Cabié, A.; de Truchis, P.; Duval, X.; Duvivier, C.; Enel, P.; Fredouille-Heripret, L.; Gasnault, J.; Gaud, C.; Katlama, C.; Khuong, M. A.; Lang, J. M.; Lascaux, A. S.; Launay, O.; Mahamat, A.; Mary-Krause, M.; Meynard, J. L.; Pavie, J.; Pialoux, G.; Pilorgé, F.; Poizot-Martin, I.; Pradier, C.; Reynes, J.; Rouveix, E.; Simon, A.; Tissot-Dupont, H.; Viard, J. P.; Viget, N.; Jacquemet, N.; Costagliola, D.; Grabar, S.; Guiguet, M.; Lanoy, E.; Lièvre, L.; Lacombe, J. M.; Potard, V.; Pitié, G. H.; Bricaire, F.; Herson, S.; Desplanque, N.; Meyohas, M. C.; Picard, O.; Cadranel, J.; Mayaud, C.; Clauvel, J. P.; Decazes, J. M.; Gerard, L.; Molina, J. M.; Lariboisière-Fernand, G. H.; Honoré, P.; Jeantils, V.; Tassi, S.; Mechali, D.; Taverne, B.; Bouvet, E.; Ecobichon, J. L.; Matheron, S.; Picard-Dahan, C.; Yeni, P.; Dupont, C.; Chandemerle, C.; Mortier, E.; Tisne-Dessus, D.; Weiss, L.; Tarnier-Cochin, G. H.; Auperin, I.; Gilquin, J.; Roudière, L.; Fior, R.; Delfraissy, J. F.; Goujard, C.; Jung, C.; Vittecoq, D.; Fraisse, P.; Beck-Wirth, G.; Stahl, J. P.; Lecercq, P.; Gourdon, F.; Laurichesse, H.; Fresard, A.; Basse-Normandie, Corevih; Bazin, C.; Verdon, R.; Bourgogne, Corevih; Bretagne, Corevih; Arvieux, C.; Michelet, C.; Goudeau, A.; Maître, M. F.; Hoen, B.; Faller, J. P.; Haute-Normandie, Corevih; Borsa-Lebas, F.; Caron, F.; Daures, J. P.; Lorraine, Corevih; May, T.; Rabaud, C.; Berger, J. L.; Rémy, G.; Arlet-Suau, E.; Cuzin, L.; Massip, P.; Legrand, M. F. Thiercelin; Pontonnier, G.; de Calais, Corevih Nord-Pas; Yasdanpanah, Y.; Dellamonica, P.; Pugliese, P.; Quinsat, D.; Ravaux, I.; Tissot, H.; Delmont, J. P.; Moreau, J.; Gastaut, J. A.; Retornaz, F.; Soubeyrand, J.; Galinier, A.; Ruiz, J. M.; Allegre, T.; Blanc, P. A.; Bonnet, D.; Lepeu, G.; Granet-Brunello, P.; Esterni, J. P.; Cohen-Valensi, R.; Nezri, M.; Chadapaud, S.; Laffeuillade, A.; Raffi, F.; Boibieux, A.; Peyramond, D.; Livrozet, J. M.; Touraine, J. L.; Strobel, M.; Saint-Martin, C. H.; Bissuel, F.; Pradinaud, R.; Sobesky, M.; Martinique, Corevih; Guyon, Félix; Contant, M.; HC, Bucher; CA, Fux; HH, Hirsch; de Tejada B, Martinez; Casabona, J.; Miró, Jose M.; de Barcelona-Idibaps, Clínic; Gallois, A.; Esteve, A.; Podzamczer, D.; Murillas, J.; Gatell, J. M.; Manzardo, C.; Tural, C.; Clotet, B.; Ferrer, E.; Riera, M.; Segura, F.; Navarro, G.; Vilaró, J.; Masabeu, A.; García, I.; Guadarrama, M.; Cifuentes, C.; Dalmau, D.; Agustí, C.; Montoliu, A.; Pérez, I.; Gargoulas, Freyra; Blanco, J. L.; Garcia-Alcaide, F.; Martínez, E.; García-Goez, J. F.; Sirera, G.; Negredo, E.; Miranda, C.; Capitan, M. C.; Saumoy, M.; Imaz, A.; Tiraboschi, J. M.; Murillo, O.; Bolao, F.; Peña, C.; Cabellos, C.; Vila, A.; Sala, M.; Cervantes, M.; Amengual, Jose; Navarro, M.; Barrufet, P.; Molina, J.; Alvaro, M.; Mercadal, J.; Fernández, Juanse; Ospina, Jesús E.; Berenguer, J.; García, F.; Gutiérrez, F.; Labarga, P.; Moreno, S.; Caro-Murillo, A. M.; Sobrino, P.; Jarrín, I.; Sirvent, J. L. Gómez; Rodríguez, P.; Alemán, M. R.; Alonso, M. M.; López, A. M.; Hernández, M. I.; Soriano, V.; Barreiro, P.; Medrano, J.; Rivas, P.; Herrero, D.; Blanco, F.; Vispo, M. E.; Martín, L.; Ramírez, G.; Rubio, R.; Pulido, F.; Moreno, V.; Cepeda, C.; Iribarren, J. A.; Camino, X.; Rodríguez-Arrondo, F.; von Wichmann, M. A.; Pascual, L.; Goenaga, M. A.; Masiá, M.; Ramos, J. M.; Padilla, S.; Sánchez-Hellín, V.; Bernal, E.; Montolio, F.; Peral, Y.; Marañón, Gregorio; López, J. C.; Miralles, P.; Cosín, J.; Sánchez, M.; Gutiérrez, I.; Ramírez, M.; Padilla, B.; Vidal, F.; Veloso, S.; Viladés, C.; López-Dupla, M.; Olona, M.; Vargas, M.; Lacruz, J.; Salavert, M.; Montero, M.; Cuéllar, S.; Sanz, J.; Oteo, J. A.; Blanco, J. R.; Ibarra, V.; Metola, L.; Sanz, M.; Pérez-Martínez, L.; Sola, J.; Uriz, J.; Castiello, J.; Reparaz, J.; Arriaza, M. J.; Irigoyen, C.; Antela, A.; Casado, J. L.; Dronda, F.; Moreno, A.; Pérez, M. J.; López, D.; Gutiérrez, C.; Martí, P.; García, L.; Page, C.; Hernández, J.; Peña, A.; Muñoz, L.; Parra, J.; Viciana, P.; Leal, M.; López-Cortés, L. F.; Mata, R.; Justice, A. C.; Rimland, D.; Jones-Taylor, C.; Oursler, K. A.; Brown, S.; Garrison, S.; Rodriguez-Barradas, M.; Masozera, N.; Goetz, M.; Leaf, D.; Simberkoff, M.; Blumenthal, D.; Leung, J.; Peck, R.; Mattocks, K.; Braithwaite, S.; Cook, R.; Conigliaro, J.; Crothers, K.; Chang, J.; Crystal, S.; Day, N.; Erdos, J.; Freiberg, M.; Kozal, M.; Gerschenson, M.; Good, B.; Gordon, A.; Goulet, J. L.; Hernán, M. A.; Kraemer, K.; Lim, J.; Maisto, S.; O'Connor, P.; Papas, R.; Robins, J. M.; Rinaldo, C.; Roberts, M.; Samet, J.; Tierney, B.; Whittle, J.; Brettle, R.; Fidler, S.; Goldberg, D.; Hawkins, D.; Jaffe, H.; Johnson, A.; McLean, K.; Porter, Kholoud; Ewings, Fiona; Fairbrother, Keith; Gnatiuc, Louisa; Murphy, Brendan; Douglas, G.; Kennedy, N.; Pritchard, J.; Andrady, U.; Gwynedd, Ysbyty; Rajda, N.; Maw, R.; McKernan, S.; Drake, S.; Gilleran, G.; White, D.; Ross, J.; Toomer, S.; Hewart, R.; Wilding, H.; Woodward, R.; Dean, G.; Heald, L.; Horner, P.; Glover, S.; Bansaal, D.; Carne, C.; Browing, M.; Stanley, B.; O'Mahony, C.; Fraser, P.; Hayman, B.; Joshi, U.; Ralph, S.; Wade, A.; Mette, R.; Lalik, J.; Summerfield, H.; El-Dalil, A.; France, A. J.; White, C.; Robertson, R.; Gordon, S.; Lean, C.; Morris, S.; Vithayathil, K.; McLean, L.; Winter, A.; Gale, D.; Jacobs, S.; Tayal, S.; Short, L.; Williams, G.; Minton, J.; Dhar, J.; Nye, F.; DeSouza, C. B.; Isaksen, A.; McDonald, L.; Franca, A.; William, L.; Peters, B.; El, S.; Easterbrook, P. J.; Mazhude, C.; Johnstone, R.; Fakoya, A.; Mchale, J.; Waters, A.; Kegg, S.; Mitchell, S.; Byrne, P.; Rice, P.; Mullaney, S. A.; McCormack, S.; David, D.; Melville, R.; Phillip, K.; Balachandran, T.; Mabey, S.; Sukthankar, A.; Murphy, C.; Wilkins, E.; Ahmad, S.; Cook, James; Haynes, J.; Keynes, Milton; Evans, E.; Ong, E.; Das, R.; Grey, R.; Meaden, J.; Bignell, C.; Loay, D.; Peacock, K.; Eliot, George; Girgis, M. R.; Morgan, B.; Palfreeman, A.; Wilcox, J.; Tobin, J.; Tucker, L.; Saeed, A. M.; Williams, O.; Clwyd, Glan; Lacey, H.; Herman, S.; Kinghorn, D.; Devendra, S. V.; Wither, J.; Dawson, S.; Rowen, D.; Harvey, J.; Chauhan, M.; Kellock, D.; Young, S.; Dannino, S.; Kathir, Y.; Rooney, G.; Currie, J.; Fitzgerald, M.; Devendra, S.; Keane, F.; Booth, G.; Arumainayyagam, J.; Chandramani, S.; Robinson, T.; Curless, E.; Gokhale, R.; Tariq, A.; Luzzi, G.; Fairley, I.; Wallis, F.; Smit, E.; Ward, F.; Loze, B.; Morlat, P.; Bonarek, M.; Bonnet, F.; Nouts, C.; Louis, I.; Reliquet, V.; Sauser, F.; Biron, C.; Mounoury, O.; Hue, H.; Brosseau, D.; Ghosn, J.; Rannou, M. T.; Bergmann, J. F.; Badsi, E.; Rami, A.; Girard, P. M.; Samanon-Bollens, D.; Campa, P.; Tourneur, M.; Desplanques, N.; Jeanblanc, F.; Chiarello, P.; Makhloufi, D.; Herriot, E.; Blanc, A. P.; Allègre, T.; Baillat, V.; Lemoing, V.; de Boever, C. Merle; Tramoni, C.; Sobesky, G.; Abel, S.; Beaujolais, V.; Slama, L.; Fournier, I.; Gerbe, J.; Trepo, C.; Koffi, K.; Miailhes, P.; Thoirain, V.; Brochier, C.; Souala, F.; Ratajczak, M.; Beytoux, J.; Jacomet, C.; Montpied, G.; Olivier, C.; Paré, A.; Lortholary, O.; Dupont, B.; Maignan, A.; Raymond, I.; Leport, C.; Jadand, C.; Jestin, C.; Longuet, P.; Boucherit, S.; Sereni, D.; Lascoux, C.; Prevoteau, F.; Sobel, A.; Levy, Y.; Lelièvre, J. D.; Mondor, H.; Aumaître, H.; Delmas, B.; Saada, M.; Medus, M.; Salmon, D.; Tahi, T.; Yazdanpanah, Y.; Pavel, S.; Marien, M. C.; Dron, C. H.; Beck, C.; Benomar, M.; Muller, E.; Tubiana, R.; Mohand, H. Ait; Touam, F.; Folzer, A.; Obadia, M.; Prudhomme, L.; Bonnet, E.; Balzarin, F.; Pichard, E.; Chennebault, J. M.; Fialaire, P.; Loison, J.; Galanaud, P.; Bornarel, D.; Six, M.; Ferret, P.; Batisse, D.; Devidas, A.; Chevojon, P.; Turpault, I.; Philip, G.; Morel, P.; Timsit, J.; Amirat, N.; Cabane, J.; Tredup, J.; Chavanet, C.; Buisson, M.; Treuvetot, S.; Choutet, P.; Bastides, F.; Boyer, L.; Wassoumbou, S.; Oksenhendeler, E.; Gérard, L.; Bernard, L.; Berthé, H.; Poincaré, R.; Domart, Y.; Merrien, D.; Belan, A. Greder; Mignot, A.; Gayraud, M.; Bodard, L.; Meudec, A.; Pape, E.; Vinceneux, P.; Simonpoli, A. M.; Zeng, A.; Mourier, L.; Fournier, L.; Jacquet, M.; Fuzibet, J. G.; Sohn, C.; Rosenthal, E.; Quaranta, M.; Sabah, M.; Audhuy, B.; Schieber, A.; Pasteur, L.; Moreau, P.; Vaillant, O.; Huchon, G.; Compagnucci, A.; de Lacroix Szmania, I.; Lamaury, I.; Saint-Dizier, F.; Garipuy, D.; Drogoul, M. P.; Martin, I. Poizot; Fabre, G.; Lambert, G.; Lagarde, P.; David, F.; Roche-Sicot, J.; Saraux, J. L.; Leprêtre, A.; Veil, S.; Fampin, B.; Uludag, A.; Morin, A. S.; Bletry, O.; Zucman, D.; Regnier, A.; Girard, J. J.; Quinsat, D. T.; Heripret, L.; Grihon, F.; Houlbert, D.; Ruel, M.; Chemlal, K.; Debab, Y.; Nicolle, C.; Perronne, V.; Quesnay, F.; Slama, B.; Duffaut, H.; Perré, P.; Miodovski, C.; Guermonprez, G.; Dulioust, A.; Ballanger, R.; Patey, O.; Semaille, C.; Deville, J.; Beclere, Antoine; Boue, F.; Chambrin, V.; Pignon, C.; Estocq, G. A.; Levy, A.; Bicetre, Le Kremlin; Duracinsky, M.; Bras, P. Le; Ngussan, M. S.; Lambert, T.; Segeral, O.; Lezeau, P.; Laurian, Y.; Piketty, C.; Karmochkine, M.; Eliaszewitch, M.; Jayle, D.; Tisne, D.; Colasante, U.; Vilde, J. L.; Bollens, D.; Binet, D.; Diallo, B.; Lagneau, J. L.; Pietrie, M. P.; Sicard, D.; Stieltjes, N.; Michot, J.; Bourdillon, F.; Obenga, G.; Escaut, L.; Bolliot, C.; Schneider, L.; Iguertsira, M.; Stein, A.; Tomei, C.; Dhiver, C.; Gallais, J.; Gallais, H.; Durant, J.; Mondain, V.; Perbost, I.; Cassuto, J. P.; Karsenti, J. M.; Ceppi, C.; Krivitsky, J. A.; Honore, P.; Delgado, J.; Rouzioux, C.; Burgard, M.; Boufassa, L.; Peynet, J.; Pérez-Hoyos, S.; Schiaffino, A.; Monge, D. Alvarez S.; Pujol, I.; Muga, R.; Sanvisens, A.; Tor, J.; Rivas, I.; Vallecillo, G.; del Romero, J.; Raposo, P.; Rodríguez, C.; Vera, M.; Alastrue, E. Fernandez I.; Tasa, C. Santos T.; Juan, A.; Trullen, J.; de Olalla, P. Garcia; Cayla, J.; Sambeat, M. A.; Guerrero, R.; Rivera, E.; Marco, A.; Quintana, M.; Gonzalez, C.; Castilla, J.; Guevara, M.; de Mendoza, C.; Zahonero, N.; Ortíz, M.; G, Daikos; T, Kordossis; G, Panos; H, Sambatakou; M, Chini; Nelson, M.; Asboe, D.; Man, S.-L.; Smith, C.; Grabowska, H.; Gras, L. A. J.; Branger, J.; Scherpbier, H. J.; van der Meer, J. T. M.; Wit, F. W. M. N.; van der Poll, T.; Nellen, F. J. B.; Lange, J. M. A.; Geerlings, S. E.; van Vugt, M.; Frissen, P. H. J.; Schouten, W. E. M.; van den Berk, G. E. L.; Vrouenraets, S. M. E.; van Eeden, A.; Verhagen, D. W. M.; Claessen, F. A. P.; Peters, E. J. G.; van Nieuwkoop, C.; Leyten, E. M. S.; Gelinck, L. B. S.; Ziekenhuis, Catharina; Pronk, M. J. H.; Delsing, C. E.; Scholvinck, E. H.; Bierman, W. F. W.; ten Kate, R. W.; de Boer, M. G. J.; ter Vollaard, H. J. M.; Zuiderzee, M. C.; Schreij, G.; Keuter, M.; van der Ven, A. J. A. M.; ter Hofstede, H. J. M.; Dofferhoff, A. S. M.; van der Ende, M. E.; de Vries-Sluijs, T. E. M. S.; Schurink, C. A. M.; Rijnders, B. J. A.; van Gorp, E. C. M.; Smeulders, A. W. M.; den Hollander, J. G.; Hoepelman, A. I. M.; Schneider, M. M. E.; Jaspers, C. A. J. J.; Arends, J. E.; Wassenberg, M. W. M.; Geelen, S. P. M.; Wolfs, T. F. W.; Cotte, L.; Tattevin, P.; Selinger-Leneman, H.; Diemer, M.; Sellier, P.; Crickx, B.; Lesprit, Ph; Rey, D.; Lucht, F.; Chavanet, P.; Eglinger, P.; Aleksandrowicz, K.; Pelissier, L.; Aubert, V.; Barth, J.; Battegay, M.; Bernasconi, E.; Böni, J.; Burton-Jeangros, C.; Calmy, A.; Cavassini, M.; Egger, M.; Elzi, L.; Fehr, J.; Fellay, J.; Furrer, H.; Gorgievski, M.; Günthard, H.; Hasse, B.; Hösli, I.; Kahlert, C.; Kaiser, L.; Keiser, O.; Klimkait, T.; Kovari, H.; Ledergerber, B.; Martinetti, G.; Metzner, K.; Müller, N.; Nadal, D.; Pantaleo, G.; Rauch, A.; Regenass, S.; Rickenbach, M.; Rudin, C.; Schmid, P.; Schultze, D.; Schöni-Affolter, F.; Schüpbach, J.; Speck, R.; Taffé, P.; Tarr, P.; Telenti, A.; Trkola, A.; Vernazza, P.; Weber, R.; Yerly, S.; Force, L.; Mallolas, J.; López-Dieguez, M.; Romeu, J.; Jou, A.; Masó, M.; Bejarano, G.; del Amo, J.; Muñoz, M. A.; Arrizabalaga, A. J.; Aramburu, M. J.; Escolano, C.; Sanjuan, M.; Peraire, J.; Aldeguer, J. L.; Blanes, M.; de los Santos, I.; Hernández, B.; Pumares, M.; Trastoy, M.; Fiellin, D. A.; Titanji, R.; Butt, A.; Brandt, C.; Bryant, K.; Gandhi, N.; Gaziano, M.; Miller, P.; Mole, L.; Darbyshire, J.; Cursley, Adam; Eduards, S.; Estreich, S.; Magdy, A.; Jebakumar, S. P. R.; McMillan, S.; Green, S.; Sivakumar, K.; Monteiro, E.; Jendrulek, I.; Deheragada, A.; Rajamanoharan, S.; Parrinello, M.; Chakvetadze, C.; Berrebi, V.; Augustin-Normand, C.; Morelon, S.; Ragnaud, J. M.; Dominguez, S.; Dumont, C.; Drenou, B.; Drobacheff, C.; Gonzales-Canali, A.; Cheret, A.; Brancion, C.; Ravault, I.; Nau, P.; Beuscart, C.; Daniel, C.; Chaillou, S.; Niault, M.; Richier, L.; Abraham, B.; Perino, C.; Tremollieres, F.; Boudon, P.; Malbec, D.; Remy, G.; Béguinot, I.; Peretti, D.; Medintzeff, N.; Kazatchkine, M.; Fonquernie, L.; Lelievre, J. D.; Tissot Dupont, H.; Vallon, A.; Venti, H.; Bouchaud, O.; Hurtado, I.; Belda, J.; Gargalianos-Kakolyris, P.; Katsarou, O.; Lazanas, M.; Paparizos, V.; Paraskevis, D.; Skoutelis, A.; Touloumi, G.; Pantazis, N.; Bakoyannis, G.; Gioukari, V.; Antoniadou, A.; Papadopoulos, A.; Petrikkos, G.; Daikos, G.; Psichogiou, M.; Xylomenos, G.; Kouramba, A.; Ioannidou, P.; Kordossis, T.; Kontos, A.; Tsogas, N.; Leuow, K.; Kourkounti, S.; Sambatakou, H.; Mariolis, I.; Papastamopoulos, V.; Baraboutis, I.

    2015-01-01

    Recommendations have differed nationally and internationally with respect to the best time to start antiretroviral therapy (ART). We compared effectiveness of three strategies for initiation of ART in high-income countries for HIV-positive individuals who do not have AIDS: immediate initiation,

  11. POSITION-SPECIFIC DEFICIT OF JOINT POSITION SENSE IN ANKLES WITH CHRONIC FUNCTIONAL INSTABILITY

    Directory of Open Access Journals (Sweden)

    Shigeki Yokoyama

    2008-12-01

    Full Text Available The present study was aimed to test a hypothesis that individuals with functional ankle instability (FAI underestimate the joint angle at greater plantarflexion and inversion. Seventeen males with unilateral FAI and 17 controls (males without FAI consented for participation in this IRB-approved, case-control study. Using a passive reproduction test, we assessed ankle joint position sense (JPS for test positions between 30 and -10 degrees plantarflexion with an inclement of 10 degrees with or without 20° inversion at each plantarflexion angle. The constant error (CE was defined as the value obtained by subtracting the true angle of a test position from the corresponding perceived angle. At plantarflexed and inverted test positions, the CE values were smaller in negative with greater in the FAI group than in the control group. That is, in the FAI group, the FAI group underestimated the true plantarflexion angle at combined 30° plantarflexion and 20° inversion. We conclude that the ankle with FAI underestimate the amount of plantarflexion, which increases the chance of reaching greater planterflexion and inversion than patients' intention at high risk situations of spraining such as landing

  12. Differential ultrasonic indices of separation distress in the presence and absence of maternal cues in infant rats bred for high and low positive social affect.

    Science.gov (United States)

    Iacobucci, Paolo; Colonnello, Valentina; Fuchs, Thomas; D'Antuono, Laura; Panksepp, Jaak

    2013-10-01

    Preclinical models of human mood disorders commonly focus on the study of negative affectivity, without comparably stressing the role of positive affects and their ability to promote resilient coping styles. We evaluated the role of background constitutional affect of rats by studying the separation and reunion responses of infants from low and high positive affect genetic lines (i.e., differentially selected for High and Low 50 kHz ultrasonic vocalisations (USVs). Infants from Low and High 50 kHz USV breeding lines were isolated from mothers and exposed to either social (familiar or unfamiliar bedding) or neutral (clean bedding) odour cues between two short isolation periods, and tested in homeothermic and hypothermic ambient temperatures. Negative affect was estimated by monitoring separation distress calls (35-45 kHz USVs). Low Line pups called at higher rates than High Line, and their rates were stable regardless of odour cue. In contrast, High Line pups increased vocalisations during the second compared with the first isolation periods and during exposure to both familiar and unfamiliar odour cues, but not to neutral odour. Furthermore, the greatest increase in USV emission was seen in the second isolation period following exposure to the unfamiliar odour. However, both lines showed comparable elevated distress USVs to the thermal stressor. High Line animals, selected for a positive affective phenotype (50 kHz USVs), exhibited reduced separation anxiety responses in infancy, making this a promising animal model for the role of constitutional affective states in emotional responsivity and potential resilience against emotional disorders.

  13. Positive Technologies for Understanding and Promoting Positive Emotions.

    Science.gov (United States)

    Baños, Rosa María; Carrillo, Alba; Etchemendy, Ernestina; Botella, Cristina

    2017-10-26

    Information and Communication Technologies (ICTs) have become increasingly present in our lives, and their use has spread considerably. This paper presents a review of the way ICTs can help practitioners and researchers to study, promote, and train positive emotions. It is framed within the field of Positive Technologies: the applied scientific approach to the study of the use of technology to improve the quality of personal experience, with the goal of increasing wellbeing. First, the article presents an introduction to the topic of technologies and positive emotions. Then, it describes how ICTs can aid in monitoring, assessing, promoting, modifying, and training positive emotions. Finally, implications and future directions of the role of Positive Technologies in positive emotions are discussed. The authors conclude that, in the near future, Positive Technologies and the field of positive emotions will interact synergistically, producing an exponential growth in the understanding and promotion of positive emotions.

  14. Static Analysis of High-Performance Fixed Fluid Power Drive with a Single Positive-Displacement Hydraulic Motor

    Directory of Open Access Journals (Sweden)

    O. F. Nikitin

    2015-01-01

    Full Text Available The article deals with the static calculations in designing a high-performance fixed fluid power drive with a single positive-displacement hydraulic motor. Designing is aimed at using a drive that is under development and yet unavailable to find and record the minimum of calculations and maximum of existing hydraulic units that enable clear and unambiguous performance, taking into consideration an available assortment of hydraulic units of hydraulic drives, to have the best efficiency.The specified power (power, moment and kinematics (linear velocity or angular velocity of rotation parameters of the output element of hydraulic motor determine the main output parameters of the hydraulic drive and the useful power of the hydraulic drive under development. The value of the overall efficiency of the hydraulic drive enables us to judge the efficiency of high-performance fixed fluid power drive.The energy analysis of a diagram of the high-performance fixed fluid power drive shows that its high efficiency is achieved when the flow rate of fluid flowing into each cylinder and the magnitude of the feed pump unit (pump are as nearly as possible.The paper considers the ways of determining the geometric parameters of working hydromotors (effective working area or working volume, which allow a selection of the pumping unit parameters. It discusses the ways to improve hydraulic drive efficiency. Using the principle of holding constant conductivity allows us to specify the values of the pressure losses in the hydraulic units used in noncatalog modes. In case of no exact matching between the parameters of existing hydraulic power modes and a proposed characteristics of the pump unit, the nearest to the expected characteristics is taken as a working version.All of the steps allow us to create the high-performance fixed fluid power drive capable of operating at the required power and kinematic parameters with high efficiency.

  15. Persistent Low-Risk and High-Risk Human Papillomavirus Infections of the Uterine Cervix in HIV-Negative and HIV-Positive Women

    Directory of Open Access Journals (Sweden)

    Sally N. Adebamowo

    2017-07-01

    Full Text Available BackgroundThe prevalence, persistence, and multiplicity of human papillomavirus (HPV infection appears different comparing HIV-positive to HIV-negative women. In this study, we examined prevalent, persistent, and multiple low- and high-risk cervical HPV infections in HIV-negative and HIV-positive women.MethodsWe studied 1,020 women involved in a study of HPV infection using SPF25/LiPA10. Two study visits were scheduled, at enrollment and 6 months afterward. At each study visit, research nurses used a cervical brush to collect samples of exfoliated cervical cells from the cervical os, from all the study participants. Exact logistic regression models were used to estimate associations between HIV and HPV infections.ResultsThe mean (SD age of the study participants was 38 (8 years, 56% were HIV-negative and 44% were HIV-positive. Among HIV-negative women at baseline, single low-risk HPV (lrHPV infections occurred in 12%; multiple lrHPV in 2%; single high-risk human papillomavirus (hrHPV infections in 9%, and multiple hrHPV infections in 2%. Single lrHPV infections were persistent in 6%, but there was no persistent multiple lrHPV infections. Single hrHPV infections were persistent in 4% while multiple hrHPV infections were persistent in 0.3%. Among HIV-positive women at baseline, single lrHPV infections occurred in 19%, multiple lrHPV in 6%, single hrHPV infections in 17%, and multiple hrHPV infections occurred in 12%. Single lrHPV infections were persistent in 9%, multiple lrHPV infections in 0.6%, single hrHPV infections in 13%, while multiple hrHPV were persistent in 3%. Prevalent, persistent, and multiple infections were more common in HIV-positive women, compared to HIV-negative women. In multivariate models adjusted for age, marital status, socioeconomic status, age at sexual initiation, and douching, the odds ratios comparing HIV-positive to HIV-negative women, were 2.09 (95% CI 1.47–2.97, p < 0.001 for prevalent lrHPV, 1.26 (95% CI

  16. Isoniazid-resistant Mycobacterium kansasii in an HIV-positive patient, and possible development of immune reconstitution inflammatory syndrome after initiation of highly active antiretroviral therapy: case report

    Directory of Open Access Journals (Sweden)

    A. Despotovic

    2016-01-01

    Full Text Available Non-tuberculous mycobacteria are rare but important causes of infection in HIV-positive individuals. A 28-year-old HIV-positive male presented with a high fever, non-productive cough, right subcostal pain, splenomegaly, a very low CD4 count, elevated C-reactive protein and erythrocyte sedimentation rate, and a normal white blood cell count. The suspicion of tuberculosis (TB was very high, and sputum samples were positive for acid-fast bacilli. Standard quadruple anti-TB therapy was initiated, but once culture of the sample revealed Mycobacterium kansasii, pyrazinamide was withdrawn. Highly active antiretroviral therapy (HAART was initiated soon after, consisting of abacavir/lamivudine and efavirenz. The patient's general condition deteriorated 2 weeks after HAART initiation, which could have been due to the development of immune reconstitution inflammatory syndrome (IRIS. The patient recovered and was discharged in good condition. However, the results of resistance testing of the isolated organism arrived after discharge, and showed isoniazid and streptomycin resistance. This is the first case report of M. kansasii infection from Serbia and shows the difficulties encountered during the course of treatment.

  17. Predictors of positive health in disability pensioners: a population-based questionnaire study using Positive Odds Ratio

    Directory of Open Access Journals (Sweden)

    Edén Lena

    2002-09-01

    Full Text Available Abstract Background Determinants of ill-health have been studied far more than determinants of good and improving health. Health promotion measures are important even among individuals with chronic diseases. The aim of this study was to find predictors of positive subjective health among disability pensioners (DPs with musculoskeletal disorders. Methods Two questionnaire surveys were performed among 352 DPs with musculoskeletal disorders. Two groups were defined: DPs with positive health and negative health, respectively. In consequence with the health perspective in this study the conception Positive Odds Ratio was defined and used in the logistic regression analyses instead of the commonly used odds ratio. Results Positive health was associated with age ≥ 55 years, not being an immigrant, not having fibromyalgia as the main diagnosis for granting an early retirement, no regular use of analgesics, a high ADL capacity, a positive subjective health preceding the study period, and good quality of life. Conclusion Positive odds ratio is a concept well adapted to theories of health promotion. It can be used in relation to positive outcomes instead of risks. Suggested health promotion and secondary prevention efforts among individuals with musculoskeletal disorders are 1 to avoid a disability pension for individuals

  18. The Family Liaison Position in High-Poverty, Urban Schools

    Science.gov (United States)

    Dretzke, Beverly J.; Rickers, Susan R.

    2016-01-01

    This study examined the roles and responsibilities of family liaisons working in urban schools with enrollments characterized by high poverty, high mobility, and ethnic diversity. Results indicated that the major responsibilities of the liaisons were creating a trusting and welcoming environment, facilitating parent involvement in the school,…

  19. cMiCE a high resolution animal PET using continuous LSO with a statistics based positioning scheme

    CERN Document Server

    Joung Jin Hun; Lewellen, T K

    2002-01-01

    Objective: Detector designs for small animal scanners are currently dominated by discrete crystal implementations. However, given the small crystal cross-sections required to obtain very high resolution, discrete designs are typically expensive, have low packing fraction, reduced light collection, and are labor intensive to build. To overcome these limitations we have investigated the feasibility of using a continuous miniature crystal element (cMiCE) detector module for high resolution small animal PET applications. Methods: The detector module consists of a single continuous slab of LSO, 25x25 mm sup 2 in exposed cross-section and 4 mm thick, coupled directly to a PS-PMT (Hamamatsu R5900-00-C12). The large area surfaces of the crystal were polished and painted with TiO sub 2 and the short surfaces were left unpolished and painted black. Further, a new statistics based positioning (SBP) algorithm has been implemented to address linearity and edge effect artifacts that are inherent with conventional Anger sty...

  20. High Performance Motion-Planner Architecture for Hardware-In-the-Loop System Based on Position-Based-Admittance-Control

    Directory of Open Access Journals (Sweden)

    Francesco La Mura

    2018-02-01

    Full Text Available This article focuses on a Hardware-In-the-Loop application developed from the advanced energy field project LIFES50+. The aim is to replicate, inside a wind gallery test facility, the combined effect of aerodynamic and hydrodynamic loads on a floating wind turbine model for offshore energy production, using a force controlled robotic device, emulating floating substructure’s behaviour. In addition to well known real-time Hardware-In-the-Loop (HIL issues, the particular application presented has stringent safety requirements of the HIL equipment and difficult to predict operating conditions, so that extra computational efforts have to be spent running specific safety algorithms and achieving desired performance. To meet project requirements, a high performance software architecture based on Position-Based-Admittance-Control (PBAC is presented, combining low level motion interpolation techniques, efficient motion planning, based on buffer management and Time-base control, and advanced high level safety algorithms, implemented in a rapid real-time control architecture.

  1. GPS Software Packages Deliver Positioning Solutions

    Science.gov (United States)

    2010-01-01

    "To determine a spacecraft s position, the Jet Propulsion Laboratory (JPL) developed an innovative software program called the GPS (global positioning system)-Inferred Positioning System and Orbit Analysis Simulation Software, abbreviated as GIPSY-OASIS, and also developed Real-Time GIPSY (RTG) for certain time-critical applications. First featured in Spinoff 1999, JPL has released hundreds of licenses for GIPSY and RTG, including to Longmont, Colorado-based DigitalGlobe. Using the technology, DigitalGlobe produces satellite imagery with highly precise latitude and longitude coordinates and then supplies it for uses within defense and intelligence, civil agencies, mapping and analysis, environmental monitoring, oil and gas exploration, infrastructure management, Internet portals, and navigation technology."

  2. An investigation of airborne GPS/INS for high accuracy position and velocity determination

    Energy Technology Data Exchange (ETDEWEB)

    Sun, H.; Cannon, M.E. [Calgary Univ., AB (Canada). Dept. of Geomatics Engineering; Owen, T.E.; Meindl, M.A. [Sandia National Labs., Albuquerque, NM (United States)

    1993-12-31

    An airborne test using a differential GPS-INS system in a Twin Otter was conducted by Sandia National Laboratories to assess the feasibility of using the integrated system for cm-level position and cm/s velocity. The INS is a miniaturized ring-laser gyro IMU jointly developed by Sandia and Honeywell while the GPS system consists of the NovAtel GPSCard{trademark}. INS position, velocity and attitude data were computed using Sandia`s SANDAC flight computer system and logged at 4 Hz and GPS data was acquired at a 1 Hz rate. The mission was approximately 2.5 hours in duration and the aircraft reached separations of up to 19 km from the base station. The data was post-processed using a centralized Kalman filter approach in which the double differenced carrier phase measurements are used to update the INS data. The INS position is in turn used to detect and correct GPS carrier phase cycle slips and also to bridge GPS outages. Results are presented for the GPS-only case and also for integrated GPS/INS.

  3. High angle of attack position sensing for the Southampton University magnetic suspension and balance system

    Science.gov (United States)

    Parker, David H.

    1987-01-01

    An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

  4. Positive Emotional Engagement and Autism Risk

    Science.gov (United States)

    Lambert-Brown, Brittany L.; McDonald, Nicole M.; Mattson, Whitney I.; Martin, Katherine B.; Ibañez, Lisa V.; Stone, Wendy L.; Messinger, Daniel S.

    2015-01-01

    Positive emotional engagement develops in the context of face-to-face interactions during the first 6 months of life. Deficits in emotional engagement are characteristic of autism spectrum disorder (ASD) and may characterize the younger siblings of children with ASD (high-risk siblings). High-risk siblings are likely to exhibit a broad range of…

  5. Head and neck position sense.

    Science.gov (United States)

    Armstrong, Bridget; McNair, Peter; Taylor, Denise

    2008-01-01

    Traumatic minor cervical strains are common place in high-impact sports (e.g. tackling) and premature degenerative changes have been documented in sports people exposed to recurrent impact trauma (e.g. scrummaging in rugby) or repetitive forces (e.g. Formula 1 racing drivers, jockeys). While proprioceptive exercises have been an integral part of rehabilitation of injuries in the lower limb, they have not featured as prominently in the treatment of cervical injuries. However, head and neck position sense (HNPS) testing and re-training may have relevance in the management of minor sports-related neck injuries, and play a role in reducing the incidence of ongoing pain and problems with function. For efficacious programmes to be developed and tested, fundamental principles associated with proprioception in the cervical spine should be considered. Hence, this article highlights the importance of anatomical structures in the cervical spine responsible for position sense, and how their interaction with the CNS affects our ability to plan and execute effective purposeful movements. This article includes a review of studies examining position sense in subjects with and without pathology and describes the effects of rehabilitation programmes that have sought to improve position sense. In respect to the receptors providing proprioceptive information for the CNS, the high densities and complex arrays of spindles found in cervical muscles suggest that these receptors play a key role. There is some evidence suggesting that ensemble encoding of discharge patterns from muscle spindles is relayed to the CNS and that a pattern recognition system is used to establish joint position and movement. Sensory information from neck proprioceptive receptors is processed in tandem with information from the vestibular system. There are extensive anatomical connections between neck proprioceptive inputs and vestibular inputs. If positional information from the vestibular system is inaccurate or

  6. Low profile, high load vertical rolling positioning stage

    Science.gov (United States)

    Shu, Deming; Barraza, Juan

    1996-01-01

    A stage or support platform assembly for use in a synchrotron accurately positions equipment to be used in the beam line of the synchrotron. The support platform assembly includes an outer housing in which is disposed a lifting mechanism having a lifting platform or stage at its upper extremity on which the equipment is mounted. A worm gear assembly is located in the housing and is adapted to raise and lower a lifting shaft that is fixed to the lifting platform by an anti-binding connection. The lifting platform is moved vertically as the lifting shaft is moved vertically. The anti-binding connection prevents the shaft from rotating with respect to the platform, but does permit slight canting of the shaft with respect to the lifting platform so as to eliminate binding and wear due to possible tolerance mismatches. In order to ensure that the lifting mechanism does not move in a horizontal direction as it is moved vertically, at least three linear roller bearing assemblies are arranged around the outer-periphery of the lifting mechanism. One of the linear roller bearing assemblies can be adjusted so that the roller bearings apply a loading force against the lifting mechanism. Alternatively, a cam mechanism can be used to provide such a loading force.

  7. Positive technology–A powerful partnership between positive psychology and interactive technology. A discussion of potential and challenges.

    Directory of Open Access Journals (Sweden)

    Sarah Diefenbach

    2017-11-01

    Full Text Available Under the umbrella term "positive computing" concepts of positive psychology are transferred to the domain of human-computer interaction (HCI. In an interdisciplinary community psychologist, computer scientists, designers and others are exploring promising ways how to utilize interactive technology to support wellbeing and human flourishing. Along with this, the recent popularity of smartphone apps aiming at the improvement of health behavior, mindfulness and positive routines, suggests the general acceptance of technology as a facilitator of personal development. Given this, there generally seems a high potential for a technology mediated trigger of positive behavior change, especially in context of positive psychology and resource oriented approaches such as solution-focused coaching. At the same time, there is still a lack of well-founded approaches to design such technology which consider its responsible role as an "interactive coach" and systematically integrate the needed expertise of different disciplines. The present article discusses the general potential and particular challenges to support the goals of positive psychology and human desire for self-improvement through interactive technology and highlights critical steps for a successful partnership between both.

  8. Positive psychiatry: its time has come.

    Science.gov (United States)

    Jeste, Dilip V; Palmer, Barton W; Rettew, David C; Boardman, Samantha

    2015-06-01

    Traditionally, psychiatry has been defined and practiced as a branch of medicine focused on the diagnosis and treatment of mental illnesses. Based on growing empirical evidence, we believe that this definition warrants expansion to include the concept of positive psychiatry. In the present article, we provide a critical overview of this emerging field and a select review of relevant scientific literature. Positive psychiatry may be defined as the science and practice of psychiatry that seeks to understand and promote well-being through assessment and interventions involving positive psychosocial characteristics (PPCs) in people who suffer from or are at high risk of developing mental or physical illnesses. It can also benefit nonclinical populations. Positive psychiatry has 4 main components: (1) positive mental health outcomes (eg, well-being), (2) PPCs that comprise psychological traits (resilience, optimism, personal mastery and coping self-efficacy, social engagement, spirituality and religiosity, and wisdom-including compassion) and environmental factors (family dynamics, social support, and other environmental determinants of overall health), (3) biology of positive psychiatry constructs, and (4) positive psychiatry interventions including preventive ones. There are promising empirical data to suggest that positive traits may be improved through psychosocial and biological interventions. As a branch of medicine rooted in biology, psychiatry, especially with the proposed conceptualization of positive psychiatry, is well poised to provide major contributions to the positive mental health movement, thereby impacting the overall health care of the population. © Copyright 2015 Physicians Postgraduate Press, Inc.

  9. Positive Psychiatry: Its Time Has Come

    Science.gov (United States)

    Jeste, Dilip V.; Palmer, Barton W.; Rettew, David C.; Boardman, Samantha

    2017-01-01

    Traditionally, psychiatry has been defined and practiced as a branch of medicine focused on the diagnosis and treatment of mental illnesses. Based on growing empirical evidence, we believe that this definition warrants expansion to include the concept of positive psychiatry. In the present article we provide a critical overview of this emerging field and a select review of relevant scientific literature. Positive psychiatry may be defined as the science and practice of psychiatry that seeks to understand and promote well-being through assessment and interventions involving positive psychosocial characteristics (PPCs) in people who suffer from or are at high risk of developing mental or physical illnesses. It can also benefit non-clinical populations. Positive psychiatry has 4 main components: (1) positive mental health outcomes (e.g., well-being), (2) PPCs that comprise psychological traits (resilience, optimism, personal mastery and coping self-efficacy, social engagement, spirituality and religiosity, and wisdom - including compassion) and environmental factors (family dynamics, social support, and other environmental determinants of overall health), (3) biology of positive psychiatry constructs, and (4) positive psychiatry Interventions including preventive ones. There are promising empirical data to suggest that positive traits may be improved through psychosocial and biological interventions. As a branch of medicine, rooted in biology, psychiatry, especially with the proposed conceptualization of positive psychiatry, is well poised to provide major contributions to the positive mental health movement, thereby impacting the overall healthcare of the population. PMID:26132670

  10. Are positive emotions just as "positive" across cultures?

    Science.gov (United States)

    Leu, Janxin; Wang, Jennifer; Koo, Kelly

    2011-08-01

    Whereas positive emotions and feeling unequivocally good may be at the heart of well-being among Westerners, positive emotions often carry negative associations within many Asian cultures. Based on a review of East-West cultural differences in dialectical emotions, or co-occurring positive and negative feelings, we predicted culture to influence the association between positive emotions and depression, but not the association between negative emotions and depression. As predicted, in a survey of over 600 European-, immigrant Asian-, and Asian American college students, positive emotions were associated with depression symptoms among European Americans and Asian Americans, but not immigrant Asians. Negative emotions were associated with depression symptoms among all three groups. We also found initial evidence that acculturation (i.e., nativity) may influence the role of positive emotions in depression: Asian Americans fell "in between" the two other groups. These findings suggest the importance of studying the role of culture in positive emotions and in positive psychology. The use of interventions based on promoting positive emotions in clinical psychology among Asian clients is briefly discussed. 2011 APA, all rights reserved

  11. Performance of a position sensitive Si(Li) x-ray detector dedicated to Compton polarimetry of stored and trapped highly-charged ions

    International Nuclear Information System (INIS)

    Weber, G; Braeuning, H; Hess, S; Maertin, R; Spillmann, U; Stoehlker, Th

    2010-01-01

    We report on a novel two-dimensional position sensitive Si(Li) detector dedicated to Compton polarimetry of x-ray radiation arising from highly-charged ions. The performance of the detector system was evaluated in ion-atom collision experiments at the ESR storage ringe at GSI, Darmstadt. Based on the data obtained, the polarimeter efficiency is estimated in this work.

  12. Contraception in HIV-positive female adolescents

    Directory of Open Access Journals (Sweden)

    Ananworanich Jintanat

    2011-06-01

    Full Text Available Abstract Sexual behavior of HIV-positive youths, whether infected perinatally, through risky behavior or other ways, is not substantially different from that of HIV-uninfected peers. Because of highly active antiretroviral therapy, increasing number of children, infected perinatally, are surviving into adolescence and are becoming sexually active and need reproductive health services. The objective of this article is to review the methods of contraception appropriate for HIV-positive adolescents with a special focus on hormonal contraceptives. Delaying the start of sexual life and the use of two methods thereafter, one of which is the male condom and the other a highly effective contraceptive method such as hormonal contraception or an intrauterine device, is currently the most effective option for those who desire simultaneous protection from both pregnancy and sexually transmitted diseases. Health care providers should be aware of the possible pharmacokinetic interactions between hormonal contraception and antiretrovirals. There is an urgent need for more information regarding metabolic outcomes of hormonal contraceptives, especially the effect of injectable progestins on bone metabolism, in HIV-positive adolescent girls.

  13. Detecting positive quadrant dependence and positive function dependence

    NARCIS (Netherlands)

    Janic-Wróblewska, A.; Kallenberg, W.C.M.; Ledwina, T.

    2004-01-01

    There is a lot of interest in positive dependence going beyond linear correlation. In this paper three new rank tests for testing independence against positive dependence are introduced. The first one is directed on positive quadrant dependence, the second and third one concentrate on positive

  14. Detecting positive quadrant dependence and positive function dependence

    NARCIS (Netherlands)

    Janic-Wróblewska, A.; Kallenberg, W.C.M.; Ledwina, T.

    2003-01-01

    There is a lot of interest in positive dependence going beyond linear correlation. In this paper three new rank tests for testing independence against positive dependence are introduced. The first one is directed on positive quadrant dependence, the second and third one concentrate on positive

  15. High positive end-expiratory pressure levels promote bacterial translocation in experimental pneumonia

    NARCIS (Netherlands)

    Lachmann, Robert A.; van Kaam, Anton H.; Haitsma, Jack J.; Lachmann, Burkhard

    2007-01-01

    A previous study in piglets with experimental pneumonia showed that reducing atelectasis by means of open lung ventilation attenuated bacterial translocation compared to conventional ventilation settings. This study examined the effect of open lung ventilation with higher than necessary positive

  16. Perceived parenting, school climate and positive youth development ...

    African Journals Online (AJOL)

    For this purpose, 400 female high school students of Kerman responded to the scale of parenting style perception, school climate perception, and positive youth development. The results of correlation analysis indicated a positive and significant correlation between school climate dimensions (teacher support, autonomy ...

  17. Technique for positioning hologram for balancing large data capacity with fast readout

    Science.gov (United States)

    Shimada, Ken-ichi; Hosaka, Makoto; Yamazaki, Kazuyoshi; Onoe, Shinsuke; Ide, Tatsuro

    2017-09-01

    The technical difficulty of balancing large data capacity with a high data transfer rate in holographic data storage systems (HDSSs) is significantly high because of tight tolerances for physical perturbation. From a system margin perspective in terabyte-class HDSSs, the positioning error of a holographic disc should be within about 10 µm to ensure high readout quality. Furthermore, fine control of the positioning should be accomplished within a time frame of about 10 ms for a high data transfer rate of the Gbps class, while a conventional method based on servo control of spindle or sled motors can rarely satisfy the requirement. In this study, a new compensation method for the effect of positioning error, which precisely controls the positioning of a Nyquist aperture instead of a holographic disc, has been developed. The method relaxes the markedly low positional tolerance of a holographic disc. Moreover, owing to the markedly light weight of the aperture, positioning control within the required time frame becomes feasible.

  18. Development of a high-count-rate neutron detector with position sensitivity and high efficiency

    International Nuclear Information System (INIS)

    Nelson, R.; Sandoval, J.

    1996-01-01

    While the neutron scattering community is bombarded with hints of new technologies that may deliver detectors with high-count-rate capability, high efficiency, gamma-ray insensitivity, and high resolution across large areas, only the time-tested, gas-filled 3 He and scintillation detectors are in widespread use. Future spallation sources with higher fluxes simply must exploit some of the advanced detector schemes that are as yet unproved as production systems. Technologies indicating promise as neutron detectors include pixel arrays of amorphous silicon, silicon microstrips, microstrips with gas, and new scintillation materials. This project sought to study the competing neutron detector technologies and determine which or what combination will lead to a production detector system well suited for use at a high-intensity neutron scattering source

  19. Singularity in the positive Hall coeffcient near pre-onset temperatures in high-Tc superconductors

    Science.gov (United States)

    Vezzoli, G. C.; Chen, M. F.; Craver, F.; Moon, B. M.; Safari, A.; Burke, T.; Stanley, W.

    1990-10-01

    Hall measurements using continuous extremely slow cooling and reheating rates as well as employing eqiulibrium point-by-point conventional techniques reveals a clear anomally in RH at pre-onset temperatures near Tc in polycrystalline samples Y1Ba2Cu3O7 and Bi2Sr2Ca2Cu3O10. The anomaly has the appearance of a singularity of Dirac-delta function which parallels earlier work on La1-xSrxCuO4. Recent single crystal work on the Bi-containing high-Tc superconductor is in accord with a clearcut anomaly. The singularity is tentatively interpreted to be associated (upon cooling) with initially the removal of positive holes from the hopping conduction system of the normal state such as from the increased concentration of bound virtual excitons due to increased exciton and hole lifetimes at low temperature. Subsequently the formation of Cooper pairs by mediation from these centers (bound-holes) and/or bound excitons) may cause an ionization of these bound virtual excitons thereby re-introducing holes and electrons into the conduction system at Tc.

  20. Positive School and Classroom Environment: Precursors of Successful Implementation of Positive Youth Development Programs

    Directory of Open Access Journals (Sweden)

    Rachel C. F. Sun

    2008-01-01

    Full Text Available This case study was based on a school where the Tier 1 Program of the Project P.A.T.H.S. was integrated into the formal curriculum. In this case study, an interview with the school principal, vice-principal, and social worker was conducted in order to understand their perceptions of administrative arrangements and issues in the school, implementation characteristics, program effectiveness, program success, and overall impression. Results showed that several positive school and classroom attributes were conducive to program success, including positive school culture and belief in students' potentials, an inviting school environment, an encouraging classroom environment, high involvement of school administrative personnel, and systematic program arrangement.

  1. Design of the digitizing beam position limit detector

    International Nuclear Information System (INIS)

    Merl, R.

    1998-01-01

    The Digitizing Beam Position Limit Detector (DBPLD) is designed to identify and react to beam missteering conditions in the Advanced Photon Source (APS) storage ring. The high power of the insertion devices requires these missteering conditions to result in a beam abort in less than 2 milliseconds. Commercially available beam position monitors provide a voltage proportional to beam position immediately upstream and downstream of insertion devices. The DBPLD is a custom VME board that digitizes these voltages and interrupts the heartbeat of the APS machine protection system when the beam position exceeds its trip limits

  2. Spin effects in nonlinear Compton scattering in a plane-wave laser pulse

    International Nuclear Information System (INIS)

    Boca, Madalina; Dinu, Victor; Florescu, Viorica

    2012-01-01

    We study theoretically the electron angular and energy distribution in the non-linear Compton effect in a finite plane-wave laser pulse. We first present analytical and numerical results for unpolarized electrons (described by a Volkov solution of the Dirac equation), in comparison with those corresponding to a spinless particle (obeying the Klein–Gordon equation). Then, in the spin 1/2 case, we include results for the spin flip probability. The regime in which the spin effects are negligible, i.e. the results for the unpolarized spin 1/2 particle coincide practically with those for the spinless particle, is the same as the regime in which the emitted radiation is well described by classical electrodynamics.

  3. Position sensitive x-ray detector

    International Nuclear Information System (INIS)

    Macchione, E.L.A.

    1990-01-01

    A multi ware position sensitive gas counter for X-ray detection was developed in our laboratory, making use of commercial delay-lines for position sensing. Six delay-line chips (50 ns delay each, 40 Mhz cut-off frequency) cover a total sensitive length of 150 mm leading to a delay-risetime ratio that allows for a high-resolution position detection. Tests using the 5,9 keV X-ray line from a 55 Fe source and integral linearity better than 0,1% and a maximal differential linearity of ±4,0% were obtained operating the detector with an Ar-C H 4 (90%-10%) gas mixture at 700 torr. Similar tests were performed, using the 8,04 keV line from a Cu x-ray tube. A total resolution of 330 μm, and the same integral and differential linearities were obtained. (author)

  4. Investigation of the paramagnetic phase of bcc iron using polarized neutron scattering

    International Nuclear Information System (INIS)

    Wicksted, J.P.; Shirane, G.; Steinsvoll, O.

    1983-01-01

    Recent neutron scattering experiments on Ni and Fe (4%-Si) above T/sub c/ have demonstrated that a simple paramagnetic scattering function S(Qω) proportional to 1/(kappa 1 2 + q 2 ).GAMMA/(GAMMA 2 + ω 2 ) can explain the persistent spin wave ridges previously reported by Lynn and Mook. We present our new polarized beam results on pure Fe and describe in some detail the special problems associated with the unpolarized beam studies of magnetic cross sections at high temperatures

  5. ELSA

    International Nuclear Information System (INIS)

    Husmann, D.; Althoff, K.H.; von Drachenfels, W.; Driest, A.; Ebeling, H.; Kaul, O.; Lippert, C.; Neckenig, M.; Nuhn, H.D.; Schauerte, W.; Schillo, M.; Schittko, F.J.; Wermelskirchen, C.

    1988-01-01

    This paper reports on the Electron Stretcher Accelerator ELSA that provides unpolarized and polarized electron beams at energies between 0.5 and 3.5 GeV at high duty factor up to 99%. ELSA partly will also serve as a synchrotron radiation source in the vacuum ultra violet and x-ray region. ELSA is a circular accelerator of 165 m circumference. The Bonn 2.5 GeV Electron Synchrotron which came into operation in 1967 is used as the injector

  6. How social position of origin relates to intelligence and level of education when adjusting for attained social position.

    Science.gov (United States)

    Sorjonen, Kimmo; Hemmingsson, Tomas; Lundin, Andreas; Melin, Bo

    2011-06-01

    Intelligence and its relationship to achievement is a classical question within psychology. In accordance with earlier British studies, the present study, based on conscription data and follow-ups for Swedish men born 1949-51 (N = 36,156), found that when adjusting for attained social position, people with a high social position of origin tend to have higher intelligence and level of education than people with a lower social position of origin. These results could be seen to contradict the claim that more merit, at least when operationalized as intelligence or education, is required from people with a low social position of origin in order to attain a certain social level. © 2011 The Authors. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.

  7. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  8. When it hurts, a positive attitude may help: association of positive affect with daily walking in knee osteoarthritis. Results from a multicenter longitudinal cohort study.

    Science.gov (United States)

    White, Daniel K; Keysor, Julie J; Neogi, Tuhina; Felson, David T; LaValley, Michael; Gross, K Doug; Niu, Jingbo; Nevitt, Michael; Lewis, Cora E; Torner, Jim; Fredman, Lisa

    2012-09-01

    While depressive symptoms and knee pain are independently known to impede daily walking in older adults, it is unknown whether positive affect promotes daily walking. This study investigated this association among adults with knee osteoarthritis (OA) and examined whether knee pain modified this association. This study is a cross-sectional analysis of the Multicenter Osteoarthritis Study. We included 1,018 participants (mean ± SD age 63.1 ± 7.8 years, 60% women) who had radiographic knee OA and had worn a StepWatch monitor to record their number of steps per day. High and low positive affect and depressive symptoms were based on the Center for Epidemiologic Studies Depression Scale. Knee pain was categorized as present in respondents who reported pain on most days at both a clinic visit and a telephone screening. Compared to respondents with low positive affect (27% of all respondents), those with high positive affect (63%) walked a similar number of steps per day, while those with depressive symptoms (10%) walked less (adjusted β -32.6 [95% confidence interval (95% CI) -458.9, 393.8] and -579.1 [95% CI -1,274.9, 116.7], respectively). There was a statistically significant interaction of positive affect by knee pain (P = 0.0045). Among the respondents with knee pain (39%), those with high positive affect walked significantly more steps per day (adjusted β 711.0 [95% CI 55.1, 1,366.9]) than those with low positive affect. High positive affect was associated with more daily walking among adults with painful knee OA. Positive affect may be an important psychological factor to consider for promoting physical activity among people with painful knee OA. Copyright © 2012 by the American College of Rheumatology.

  9. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  10. Postmastectomy radiotherapy improves disease-free survival of high risk of locoregional recurrence breast cancer patients with T1-2 and 1 to 3 positive nodes.

    Directory of Open Access Journals (Sweden)

    Zhen-Yu He

    Full Text Available The indications for post-mastectomy radiotherapy (PMRT with T1-2 breast cancer and 1-3 positive axillary lymph nodes is still controversial. The purpose of this study was to investigate the role of PMRT in T1-2 breast cancer with 1-3 positive axillary lymph node.We retrospectively reviewed the file records of 79 patients receiving PMRT and not receiving PMRT (618 patients.The median follow-up was 65 months. Multivariate analysis showed that PMRT was an independent prognostic factor of locoregional recurrence-free survival (LRFS (P = 0.010. Subgroup analysis of patients who did not undergo PMRT showed that pT stage, number of positive axillary lymph nodes, and molecular subtype were independent prognostic factors of LRFS. PMRT improved LRFS in the entire group (P = 0.005, but did not affect distant metastasis-free survival (DMFS (P = 0.494, disease-free survival (DFS (P = 0.215, and overall survival (OS (P = 0.645. For patients without PMRT, the 5-year LRFS of low-risk patients (0-1 risk factor for locoregional recurrence of 94.5% was significantly higher than that of high-risk patients (2-3 risk factors for locoregional recurrence (80.9%, P < 0.001. PMRT improved LRFS (P = 0.001 and DFS (P = 0.027 in high-risk patients, but did not improve LRFS, DMFS, DFS, and OS in low-risk patients.PMRT is beneficial in patients with high risk of locoregional recurrence breast cancer patients with T1-2 and 1 to 3 positive nodes.

  11. Relationship of condylar position to disc position and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Incesu, L.; Taskaya-Yilmaz, N. E-mail: nergizy@omu.edu.tr; Oeguetcen-Toller, M.; Uzun, E

    2004-09-01

    Introduction/objective: The purpose of this study was to assess whether condylar position, as depicted by magnetic resonance imaging, was an indicator of disc morphology and position. Methods and material: One hundred and twenty two TMJs of 61 patients with temporomandibular joint disorder were examined. Condylar position, disc deformity and degree of anterior disc displacement were evaluated by using magnetic resonance imaging. Results and discussion: Posterior condyle position was found to be the main feature of temporomandibular joints with slight and moderate anterior disc displacement. No statistical significance was found between the condylar position, and reducing and nonreducing disc positions. On the other hand, superior disc position was found to be statistically significant for centric condylar position. Conclusion: It was concluded that posterior condyle position could indicate anterior disc displacement whereas there was no relation between the position of condyle and the disc deformity.

  12. CLIC Drive Beam Position Monitor

    CERN Document Server

    Smith, S; Gudkov, D; Soby, L; Syratchev, I

    2011-01-01

    CLIC, an electron-positron linear collider proposed to probe the TeV energy scale, is based on a two-beam scheme where RF power to accelerate a high energy luminosity beam is extracted from a high current drive beam. The drive beam is efficiently generated in a long train at modest frequency and current then compressed in length and multiplied in frequency via bunch interleaving. The drive beam decelerator requires >40000 quadrupoles, each holding a beam position monitor (BPM). Though resolution requirements are modest (2 microns) these BPMs face several challenges. They must be compact and inexpensive. They must operate below waveguide cutoff to insure locality of position signals, ruling out processing at the natural 12 GHz bunch spacing frequency. Wakefields must be kept low. We find compact conventional stripline BPM with signals processed below 40 MHz can meet requirements. Choices of mechanical design, operating frequency, bandwidth, calibration and processing algorithm are presented. Calculations of wa...

  13. Spectral Stokes singularities of partially coherent radially polarized beams focused by a high numerical aperture objective

    International Nuclear Information System (INIS)

    Luo, Yamei; Lü, Baida

    2010-01-01

    The dynamic behavior of spectral Stokes singularities of partially coherent radially polarized beams focused by a high numerical aperture (NA) objective is studied by using the vectorial Debye diffraction theory and complex spectral Stokes fields. It is shown that there exist s 12 , s 23 , and s 31 singularities, as well as P (completely polarized) and U (unpolarized) singularities. The motion, pair creation and annihilation, and changes in the degree of polarization of s 12 , s 23 , and s 31 singularities, and the handedness reversal of s 12 singularities (C-points) may appear by varying a controlling parameter, such as the truncation parameter, NA, or spatial correlation length. The creation and annihilation occur for a pair of s 12 singularities with opposite topological charge but the same handedness, and for a pair of oppositely charged s 23 or s 31 singularities. The critical value of the truncation parameter, at which the pair annihilation takes place, increases as the semi-angle of the aperture lens (or, equivalently, NA) or spatial correlation length increases. The collision of an s 12 singularity with an L-line (s 3 = 0 contour) leads to a V-point, which is located at the intersection of contours of s 12 = 0 and s 23 = 0 (or s 31 = 0) and is unstable

  14. MAGIX. Progressing towards a new experiment

    Energy Technology Data Exchange (ETDEWEB)

    Caiazza, Sabato Stefano [Institut fuer Kernphysik, JGU Mainz (Germany); Collaboration: Magix/MESA-Collaboration

    2016-07-01

    In the next years, the Institut fuer Kernphysik at the Johannes Gutenberg-Universitaet Mainz, will build a new high-intensity accelerator for low-energy polarized electron beams. The MAGIX experiment will be one of the two exploiting this new machine. This experiment is designed to perform high precision measurement on the intense beam provided by the accelerator with polarized an unpolarized gas targets. This report will present an overview of the experiment and of its objectives, focussing on the development of the first prototypes of the experimental components and the first simulations of the experimental performances with an outlook on the future perspectives.

  15. Intrapartum Ultrasound Assessment of Fetal Spine Position

    Directory of Open Access Journals (Sweden)

    Salvatore Gizzo

    2014-01-01

    Full Text Available We investigated the role of foetal spine position in the first and second labour stages to determine the probability of OPP detection at birth and the related obstetrical implications. We conducted an observational-longitudinal cohort study on uncomplicated cephalic single foetus pregnant women at term. We evaluated the accuracy of ultrasound in predicting occiput position at birth, influence of fetal spine in occiput position during labour, labour trend, analgesia request, type of delivery, and indication to CS. The accuracy of the foetal spinal position to predict the occiput position at birth was high at the first labour stage. At the second labour stage, CS (40.3% and operative vaginal deliveries (23.9% occurred more frequently in OPP than in occiput anterior position (7% and 15.2%, resp., especially in cases of the posterior spine. In concordant posterior positions labour length was greater than other ones, and analgesia request rate was 64.1% versus 14.7% for all the others. The assessment of spinal position could be useful in obstetrical management and counselling, both before and during labour. The detection of spinal position, more than OPP, is predictive of successful delivery. In concordant posterior positions, the labour length, analgesia request, operative delivery, and caesarean section rate are higher than in the other combination.

  16. A High Dynamic-Range Beam Position Measurement System for ELSA-2

    CERN Document Server

    Balleyguier, P; Guimbal, P; Borrion, H

    2003-01-01

    New beamlines are presently under construction for ELSA, a 20 MeV electron linac located at Bruyères-le-Châtel. These lines need a beam position measurement system filling the following requirements: small footprint, wide dynamic range, single-bunch/multi-bunch capability, simple design. We designed a compact 4-stripline sensor and an electronic treatment chain based on logarithmic amplifiers. This paper presents the design, cold and hot test results.

  17. High Efficiency, Low EMI and Positioning Tolerant Wireless Charging of EVs

    Energy Technology Data Exchange (ETDEWEB)

    Chabaan, Rakan [Hyundai American Technical Center Inc. (HATCI), Superior Twp, MI (United States)

    2017-12-01

    The objective of this project is to develop, implement, and demonstrate a wireless power transfer (WPT) system that is capable of the following metrics: Total system efficiencies of more than 85 percent with minimum 20 cm coil-to-coil gap; System output power at least 6.6 kW; but design system up to 19.2 kW for future higher power study; Maximum lateral positioning tolerance achievable while meeting regulatory emission guidelines.

  18. A high count rate position decoding and energy measuring method for nuclear cameras using Anger logic detectors

    International Nuclear Information System (INIS)

    Wong, W.H.; Li, H.; Uribe, J.

    1998-01-01

    A new method for processing signals from Anger position-sensitive detectors used in gamma cameras and PET is proposed for very high count-rate imaging where multiple-event pileups are the norm. This method is designed to sort out and recover every impinging event from multiple-event pileups while maximizing the collection of scintillation signal for every event to achieve optimal accuracy in the measurement of energy and position. For every detected event, this method cancels the remnant signals from previous events, and excludes the pileup of signals from following events. The remnant subtraction is exact even for multiple pileup events. A prototype circuit for energy recovery demonstrated that the maximum count rates can be increased by more than 10 times comparing to the pulse-shaping method, and the energy resolution is as good as pulse shaping (or fixed integration) at low count rates. At 2 x 10 6 events/sec on NaI(Tl), the true counts acquired with this method is 3.3 times more than the delay-line clipping method (256 ns clipping) due to events recovered from pileups. Pulse-height spectra up to 3.5 x 10 6 events/sec have been studied. Monte Carlo simulation studies have been performed for image-quality comparisons between different processing methods

  19. Long-term neuromuscular training and ankle joint position sense.

    Science.gov (United States)

    Kynsburg, A; Pánics, G; Halasi, T

    2010-06-01

    Preventive effect of proprioceptive training is proven by decreasing injury incidence, but its proprioceptive mechanism is not. Major hypothesis: the training has a positive long-term effect on ankle joint position sense in athletes of a high-risk sport (handball). Ten elite-level female handball-players represented the intervention group (training-group), 10 healthy athletes of other sports formed the control-group. Proprioceptive training was incorporated into the regular training regimen of the training-group. Ankle joint position sense function was measured with the "slope-box" test, first described by Robbins et al. Testing was performed one day before the intervention and 20 months later. Mean absolute estimate errors were processed for statistical analysis. Proprioceptive sensory function improved regarding all four directions with a high significance (pneuromuscular training has improved ankle joint position sense function in the investigated athletes. This joint position sense improvement can be one of the explanations for injury rate reduction effect of neuromuscular training.

  20. Battery effect in 'electric current arising from unpolarized polyvinyl ...

    Indian Academy of Sciences (India)

    Unknown

    metal systems are ... The system would thus approach a primary battery, with the generation of. 'spontaneous' current, albeit low. In such a situation, to invoke work functions of pure, film-free (as ... ctrodes embedded in low resistance electrolytes.

  1. Risk for mania and positive emotional responding: too much of a good thing?

    Science.gov (United States)

    Gruber, June; Johnson, Sheri L; Oveis, Christopher; Keltner, Dacher

    2008-02-01

    Although positive emotion research has begun to flourish, the extremes of positive emotion remain understudied. The present research used a multimethod approach to examine positive emotional disturbance by comparing participants at high and low risk for episodes of mania, which involves elevations in positive emotionality. Ninety participants were recruited into a high or low mania risk group according to responses on the Hypomanic Personality Scale. Participants' subjective, expressive, and physiological emotional responses were gathered while they watched two positive, two negative, and one neutral film clip. Results suggested that participants at high risk for mania reported elevated positive emotion and irritability and also exhibited elevated cardiac vagal tone across positive, negative, and neutral films. Discussion focuses on the implications these findings have for the diagnosis and prevention of bipolar disorder, as well as for the general study of positive emotion.

  2. Development of a positive column pulsed capillary discharge source for use with high resolution Fourier transform spectrometer

    International Nuclear Information System (INIS)

    Syed, W A A

    2002-01-01

    We report the designing and application of a positive column pulsed capillary discharge with the Fourier transform spectrometer (FTS). The pulsed light source has been used for the first time with the ultraviolet FTS. The experiment has been carried out with the high energy pulsed discharge with energy of 2-3 J lasting about 300 ns. A system has been developed to trigger the discharge at about 600 Hz with the pulses directly taken from the FTS sampling system. The spectrum of Ar III has been recorded in the 19 000-50 000 cm -1 region with good signal to noise ratio. The results have opened a wide range of applications in spectroscopy of multiply ionized species

  3. Signal processors for position-sensitive detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Ken-ichi [Hosei Univ., Koganei, Tokyo (Japan). Coll. of Engineering

    1996-07-01

    Position-sensitive detectors (PSD) are widely used in following various fields: condensed matter studies, material engineering, medical radiology particle physics, astrophysics and industrial applications. X-ray diffraction analysis is one of the field where PSDs are the most important instruments. In this field, many types of PSAs are employed: position-sensitive proportional counters (PSPC), multi-wire proportional chambers (MWPC), imaging plates, image intensifiers combined CCD cameras and semiconductor array devices. Two readout systems used for PSDs, where one is a charge-division type with high stability and the other is an encoder with multiple delay, line readout circuits useful for fast counting, were reported in this paper. The multiple delay line encoding system can be applicable to high counting rate 1D and 2D gas proportional detectors. (G.K.)

  4. Prioritizing Positivity: An Effective Approach to Pursuing Happiness?

    Science.gov (United States)

    Catalino, Lahnna I.; Algoe, Sara B.; Fredrickson, Barbara L.

    2017-01-01

    A decade of research reveals the benefits of positive emotions for mental and physical health; however, recent empirical work suggests the explicit pursuit of happiness may backfire. The present study hypothesized that the pursuit of happiness is not inherently self-defeating; in particular, individuals who seek positivity, as exemplified by how they make decisions about how to organize their day-to-day lives, may be happier. This individual difference is labeled prioritizing positivity. In a community sample of young to older adults (N = 233), prioritizing positivity predicted a host of well-being outcomes (positive emotions, depressive symptomology). In addition, people high in prioritizing positivity have greater resources, and these links are explained by more frequent experiences of positive emotions. In sum, the present study suggests that seeking happiness, although a delicate art, may be a worthwhile pursuit. PMID:25401290

  5. The Highly Conserved Proline at Position 438 in Pseudorabies Virus gH Is Important for Regulation of Membrane Fusion

    OpenAIRE

    Schröter, Christina; Klupp, Barbara G.; Fuchs, Walter; Gerhard, Marika; Backovic, Marija; Rey, Felix A.; Mettenleiter, Thomas C.

    2014-01-01

    Membrane fusion in herpesviruses requires viral glycoproteins (g) gB and gH/gL. While gB is considered the actual fusion protein but is nonfusogenic per se, the function of gH/gL remains enigmatic. Crystal structures for different gH homologs are strikingly similar despite only moderate amino acid sequence conservation. A highly conserved sequence motif comprises the residues serine-proline-cysteine corresponding to positions 437 to 439 in pseudorabies virus (PrV) gH. The PrV-gH structure sho...

  6. cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme

    International Nuclear Information System (INIS)

    Joung Jinhun; Miyaoka, R.S.; Lewellen, T.K.

    2002-01-01

    Objective: Detector designs for small animal scanners are currently dominated by discrete crystal implementations. However, given the small crystal cross-sections required to obtain very high resolution, discrete designs are typically expensive, have low packing fraction, reduced light collection, and are labor intensive to build. To overcome these limitations we have investigated the feasibility of using a continuous miniature crystal element (cMiCE) detector module for high resolution small animal PET applications. Methods: The detector module consists of a single continuous slab of LSO, 25x25 mm 2 in exposed cross-section and 4 mm thick, coupled directly to a PS-PMT (Hamamatsu R5900-00-C12). The large area surfaces of the crystal were polished and painted with TiO 2 and the short surfaces were left unpolished and painted black. Further, a new statistics based positioning (SBP) algorithm has been implemented to address linearity and edge effect artifacts that are inherent with conventional Anger style positioning schemes. To characterize the light response function (LRF) of the detector, data were collected on a coarse grid using a highly collimated coincidence setup. The LRF was then estimated using cubic spline interpolation. Detector performance has been evaluated for both SBP and Anger based decoding using measured data and Monte Carlo simulations. Results: Using the SBP scheme, edge artifacts were successfully handled. Simulation results show that the useful field of view (UFOV) was extended to ∼22x22 mm 2 with an average point spread function of ∼0.5 mm full width of half maximum (FWHM PSF ). For the same detector with Anger decoding the UFOV of the detector was ∼16x16 mm 2 with an average FWHM PSP of ∼0.9 mm. Experimental results yielded similar differences between FOV and resolution performance. FWHM PSF for the SBP and Anger based method was 1.4 and 2.0 mm, uncorrected for source size, with a 1 mm diameter point source, respectively. Conclusion

  7. A new measurement method of actual focal spot position of an x-ray tube using a high-precision carbon-interspaced grid

    Science.gov (United States)

    Lee, H. W.; Lim, H. W.; Jeon, D. H.; Park, C. K.; Cho, H. S.; Seo, C. W.; Lee, D. Y.; Kim, K. S.; Kim, G. A.; Park, S. Y.; Kang, S. Y.; Park, J. E.; Kim, W. S.; Woo, T. H.; Oh, J. E.

    2018-06-01

    This study investigated the effectiveness of a new method for measuring the actual focal spot position of a diagnostic x-ray tube using a high-precision antiscatter grid and a digital x-ray detector in which grid magnification, which is directly related to the focal spot position, was determined from the Fourier spectrum of the acquired x-ray grid’s image. A systematic experiment was performed to demonstrate the viability of the proposed measurement method. The hardware system used in the experiment consisted of an x-ray tube run at 50 kVp and 1 mA, a flat-panel detector with a pixel size of 49.5 µm, and a high-precision carbon-interspaced grid with a strip density of 200 lines/inch. The results indicated that the focal spot of the x-ray tube (Jupiter 5000, Oxford Instruments) used in the experiment was located approximately 31.10 mm inside from the exit flange, well agreed with the nominal value of 31.05 mm, which demonstrates the viability of the proposed measurement method. Thus, the proposed method can be utilized for system’s performance optimization in many x-ray imaging applications.

  8. Thermal Stability of Magnetic Compass Sensor for High Accuracy Positioning Applications

    OpenAIRE

    Van-Tang PHAM; Dinh-Chinh NGUYEN; Quang-Huy TRAN; Duc-Trinh CHU; Duc-Tan TRAN

    2015-01-01

    Using magnetic compass sensors in angle measurements have a wide area of application such as positioning, robot, landslide, etc. However, one of the most phenomenal that affects to the accuracy of the magnetic compass sensor is the temperature. This paper presents two thermal stability schemes for improving performance of a magnetic compass sensor. The first scheme uses the feedforward structure to adjust the angle output of the compass sensor adapt to the variation of the temperature. The se...

  9. Highly potent analogues of luteinizing hormone-releasing hormone containing D-phenylalanine nitrogen mustard in position 6.

    Science.gov (United States)

    Bajusz, S; Janaky, T; Csernus, V J; Bokser, L; Fekete, M; Srkalovic, G; Redding, T W; Schally, A V

    1989-08-01

    The nitrogen mustard derivatives of 4-phenylbutyric acid and L-phenylalanine, called chlorambucil (Chl) and melphalan (Mel), respectively, have been incorporated into several peptide hormones, including luteinizing hormone-releasing hormone (LH-RH). The alkylating analogues of LH-RH were prepared by linking Chl, as an N-acyl moiety, to the complete amino acid sequence of agonistic and antagonistic analogues. These compounds, in particular the antagonistic analogues, showed much lower potency than their congeners carrying other acyl groups. To obtain highly potent alkylating analogues of LH-RH, the D enantiomer of Mel was incorporated into position 6 of the native hormone and some of its antagonistic analogues. Of the peptides prepared, [D-Mel6]LH-RH (SB-05) and [Ac-D-Nal(2)1,D-Phe(pCl)2,D-Pal(3)3,Arg5,D-Mel6,D-Ala10++ +]LH-RH [SB-86, where Nal(2) is 3-(2-naphthyl)alanine and Pal(3) is 3-(3-pyridyl)alanine] possessed the expected high agonistic and antagonistic activities, respectively, and also showed high affinities for the membrane receptors of rat pituitary cells, human breast cancer cells, human prostate cancer cells, and rat Dunning R-3327 prostate tumor cells. These two analogues exerted cytotoxic effects on human and rat mammary cancer cells in vitro. Thus these two D-Mel6 analogues seem to be particularly suitable for the study of how alkylating analogues of LH-RH could interfere with intracellular events in certain cancer cells.

  10. Highly potent analogues of luteinizing hormone-releasing hormone containing D-phenylalanine nitrogen mustard in position 6

    International Nuclear Information System (INIS)

    Bajusz, S.; Janaky, T.; Csernus, V.J.; Bokser, L.; Fekete, M.; Srkalovic, G.; Redding, T.W.; Schally, A.V.

    1989-01-01

    The nitrogen mustard derivatives of 4-phenylbutyric acid and L-phenylalanine, called chlorambucil (Chl) and melphalan (Mel), respectively, have been incorporated into several peptide hormones, including luteinizing hormone-releasing hormone (LH-RH). The alkylating analogues of LH-RH were prepared by linking Chl, as an N-acyl moiety, to the complete amino acid sequence of agonistic and antagonistic analogues. These compounds, in particular the antagonistic analogues, showed much lower potency than their congeners carrying other acyl groups. To obtain highly potent alkylating analogues of LH-RH, the D enantiomer of Mel was incorporated into position 6 of the native hormone and some of its antagonistic analogues. Of the peptides prepared, [D-Mel 6 ]LH-RH (SB-05) and [Ac-D-Nal(2) 1 ,D-Phe(pCl) 2 ,D-Pal(3) 3 ,Arg 5 ,D-Mel 6 ,D-Ala 10 ]LH-RH [SB-86, where Nal(2) is 3-(2-naphthyl)alanine and Pal(3) is 3-(3-pyridyl)alanine] possessed the expected high agonistic and antagonistic activities, respectively, and also showed high affinities for the membrane receptors of rat pituitary cells, human breast cancer cells, human prostate cancer cells, and rat Dunning R-3327 prostate tumor cells. These two analogues exerted cytotoxic effects on human and rat mammary cancer cells in vitro. Thus these two D-Mel 6 analogues seem to be particularly suitable for the study of how alkylating analogues of LH-RH could interfere with intracellular events in certain cancer cells

  11. High Precision Positioning at Field Camp: Using GNSS as the primary data source to answer geologic questions

    Science.gov (United States)

    Crosby, B. T.; Lauer, I. H.; Pratt-Sitaula, B.

    2017-12-01

    Thanks to the availability and accessibility of GPS/GNSS enabled consumer grade positioning devices, GNSS are nearly ubiquitous in both geologic field research and education. Though the devices offer sufficient precision to geotag images, digital field book entries or measurements, positions themselves are not precise enough to accomplish independent geodetic analysis. As a consequence, most students learn about GNSS at a tool that aids other forms of geologic data acquisition rather serving as the primary source itself. To resolve this, we developed and tested a three-unit teaching module within the GETSI - SERC curriculum framework that reinforces high precision positioning as a primary source of geologic data. Units focus on three core topics: GNSS Fundamentals, Kinematic GNSS and Static GNSS Methods. Module goals enable students to (a) design and conduct a GNSS survey to answer a geologic question, (b) justify why their GNSS technique is appropriate to their question and (c) to articulate how answering their question benefits society. Skill building is via quantitative and qualitative analysis, concept sketches, and both field and office based data acquisition and interrogation. Exercises are site-independent and include example datasets for those unable to travel. In the summer of 2017, we tested the module with 20 undergraduate students over two days at the ISU field geology course. Located in the Lost River Range of Idaho, positioned among active normal faults, we not only explored the use of static GNSS data for active tectonics but visited a station in person. For a summative assessment, we focused on kinematic GNSS, using RTK rovers to reoccupy leveling monuments spanning the active Lost River fault that ruptured in 1983 (M 7.0). The data collected by our class quantified aseismic deformation occurring in the 30+ years since that event. Displacements were significantly larger than the instrumental uncertainty, confirming that RTK was an appropriate tool

  12. Group identity and positive deviance in work groups.

    Science.gov (United States)

    Kim, Moon Joung; Choi, Jin Nam

    2017-12-05

    This study examines why and how identity cognitions, including group identification and individual differentiation, influence the positive deviance of employees. We identify the risk-taking intention of employees as a critical psychological mechanism to overcome stigma-induced identity threat of positive deviance. The analysis of data collected from 293 members comprising 66 work teams reveals that the relationship between individual differentiation and positive deviance is partially mediated by risk-taking intention. The indirect effect of group identification on positive deviance through risk-taking intention is also significant and positive in groups with low conformity pressure, whereas the same indirect effect is neutralized in groups with high conformity pressure. The current analysis offers new insights into the way the group context and the identity cognition of members explain the development of positive deviance and workplace creativity.

  13. On Shocks Driven by High-mass Planets in Radiatively Inefficient Disks. II. Three-dimensional Global Disk Simulations

    Science.gov (United States)

    Lyra, Wladimir; Richert, Alexander J. W.; Boley, Aaron; Turner, Neal; Mac Low, Mordecai-Mark; Okuzumi, Satoshi; Flock, Mario

    2016-02-01

    Recent high-resolution, near-infrared images of protoplanetary disks have shown that these disks often present spiral features. Spiral arms are among the structures predicted by models of disk-planet interaction and thus it is tempting to suspect that planetary perturbers are responsible for these signatures. However, such interpretation is not free of problems. The observed spirals have large pitch angles, and in at least one case (HD 100546) it appears effectively unpolarized, implying thermal emission of the order of 1000 K (465 ± 40 K at closer inspection). We have recently shown in two-dimensional models that shock dissipation in the supersonic wake of high-mass planets can lead to significant heating if the disk is sufficiently adiabatic. Here we extend this analysis to three dimensions in thermodynamically evolving disks. We use the Pencil Code in spherical coordinates for our models, with a prescription for thermal cooling based on the optical depth of the local vertical gas column. We use a 5MJ planet, and show that shocks in the region around the planet where the Lindblad resonances occur heat the gas to substantially higher temperatures than the ambient gas. The gas is accelerated vertically away from the midplane to form shock bores, and the gas falling back toward the midplane breaks up into a turbulent surf. This turbulence, although localized, has high α values, reaching 0.05 in the inner Lindblad resonance, and 0.1 in the outer one. We find evidence that the disk regions heated up by the shocks become superadiabatic, generating convection far from the planet’s orbit.

  14. Green positive guidance and green positive life counseling for decent work and decent lives:Some empirical results

    Directory of Open Access Journals (Sweden)

    Annamaria eDi Fabio

    2016-03-01

    Full Text Available This article discusses green positive guidance and green positive life counseling for decent work and decent lives. From a green guidance perspective, the connectedness to nature construct is important both in terms of the meaning of work and life construction. The study discussed in this article analyzed the relationship between empathy and connectedness to nature, controlling for the effects of fluid intelligence and personality traits. In this connection, the Advanced Progressive Matrices (APM, the Big Five Questionnaire (BFQ, and the Interpersonal Reactivity Index (IRI were administered to 144 Italian high school students. The study revealed that connecteness to nature was not associated with fluid intelligence and was only moderately associated with personality traits. It was empathy that showed the highest association with connectedness to nature. The results open new opportunities for future research and interventions in green positive guidance/life counseling and green positive decent work.

  15. A re-assessment of high elevation treeline positions and their explanation.

    Science.gov (United States)

    Körner, Christian

    1998-07-01

    In this review I first compile data for the worldwide position of climate-driven alpine treelines. Causes for treeline formation are then discussed with a global perspective. Available evidence suggests a combination of a general thermal boundary for tree growth, with regionally variable "modulatory" forces, including the presence of certain taxa. Much of the explanatory evidence found in the literature relates to these modulatory aspects at regional scales, whereas no good explanations emerged for the more fundamental global pattern related to temperature per se, on which this review is focused. I hypothesize that the life form "tree" is limited at treeline altitudes by the potential investment, rather than production, of assimilates (growth as such, rather than photosynthesis or the carbon balance, being limited). In shoots coupled to a cold atmosphere, meristem activity is suggested to be limited for much of the time, especially at night. By reducing soil heat flux during the growing season the forest canopy negatively affects root zone temperature. The lower threshold temperature for tissue growth and development appears to be higher than 3°C and lower than 10°C, possibly in the 5.5-7.5°C range, most commonly associated with seasonal means of air temperature at treeline positions. The physiological and developmental mechanisms responsible have yet to be analyzed. Root zone temperature, though largely unknown, is likely to be most critical.

  16. Automated high-throughput quantification of mitotic spindle positioning from DIC movies of Caenorhabditis embryos.

    Directory of Open Access Journals (Sweden)

    David Cluet

    Full Text Available The mitotic spindle is a microtubule-based structure that elongates to accurately segregate chromosomes during anaphase. Its position within the cell also dictates the future cell cleavage plan, thereby determining daughter cell orientation within a tissue or cell fate adoption for polarized cells. Therefore, the mitotic spindle ensures at the same time proper cell division and developmental precision. Consequently, spindle dynamics is the matter of intensive research. Among the different cellular models that have been explored, the one-cell stage C. elegans embryo has been an essential and powerful system to dissect the molecular and biophysical basis of spindle elongation and positioning. Indeed, in this large and transparent cell, spindle poles (or centrosomes can be easily detected from simple DIC microscopy by human eyes. To perform quantitative and high-throughput analysis of spindle motion, we developed a computer program ACT for Automated-Centrosome-Tracking from DIC movies of C. elegans embryos. We therefore offer an alternative to the image acquisition and processing of transgenic lines expressing fluorescent spindle markers. Consequently, experiments on large sets of cells can be performed with a simple setup using inexpensive microscopes. Moreover, analysis of any mutant or wild-type backgrounds is accessible because laborious rounds of crosses with transgenic lines become unnecessary. Last, our program allows spindle detection in other nematode species, offering the same quality of DIC images but for which techniques of transgenesis are not accessible. Thus, our program also opens the way towards a quantitative evolutionary approach of spindle dynamics. Overall, our computer program is a unique macro for the image- and movie-processing platform ImageJ. It is user-friendly and freely available under an open-source licence. ACT allows batch-wise analysis of large sets of mitosis events. Within 2 minutes, a single movie is processed

  17. Positioning consumption

    DEFF Research Database (Denmark)

    Halkier, Bente; Keller, Margit

    2014-01-01

    positionings emerges based on empirical examples of research in parent–children consumption. Positionings are flexible discursive fixations of the relationship between the performances of the practitioner, other practitioners, media discourse and consumption activities. The basic positioning types...... are the practice maintenance and the practice change position, with different sorts of adapting in between. Media discourse can become a resource for a resistant position against social control or for an appropriating position in favour of space for action. Regardless of the current relation to a particular media......This article analyses the ways in which media discourses become a part of contested consumption activities. We apply a positioning perspective with practice theory to focus on how practitioners relate to media discourse as a symbolic resource in their everyday practices. A typology of performance...

  18. Positional plagiocephaly and excessive folic acid intake during pregnancy

    NARCIS (Netherlands)

    A.C. Michels (Alice); M.E.P. van den Elzen (Marijke); J.S.H. Vles (Johannes); R. van der Hulst (Rene)

    2012-01-01

    textabstractObjective: To assess the relationship between high intake of folic acid and positional plagiocephaly. Design: Retrospective case-control study with questionnaires administered in the clinic to biological mothers of children with positional plagiocephaly (PP group) and mothers of children

  19. Positive Psychotherapy for Smoking Cessation: Treatment Development, Feasibility and Preliminary Results.

    Science.gov (United States)

    Kahler, Christopher W; Spillane, Nichea S; Day, Anne; Clerkin, Elise; Parks, Acacia; Leventhal, Adam M; Brown, Richard A

    2014-01-01

    Low positive and high negative affect predict low rates of smoking abstinence among smokers making a quit attempt. Positive Psychotherapy can both increase positive affect and decrease negative affect and therefore may be a useful adjunct to behavioral smoking counseling. The purpose of the present study was to assess the feasibility and acceptability of a Positive Psychotherapy for Smoking Cessation (PPT-S) intervention that integrates standard smoking cessation counseling with nicotine patch and a package of positive psychology interventions. We delivered PPT-S to 19 smokers who were low in positive affect at baseline. Rates of session attendance and satisfaction with treatment were high, and most participants reported using and benefiting from the positive psychology interventions. Almost one-third of participants (31.6%) sustained smoking abstinence for 6 months after their quit date. Future studies to assess the relative efficacy of PPT-S compared to standard smoking cessation treatment are warranted.

  20. Strategies for high-precision Global Positioning System orbit determination

    Science.gov (United States)

    Lichten, Stephen M.; Border, James S.

    1987-01-01

    Various strategies for the high-precision orbit determination of the GPS satellites are explored using data from the 1985 GPS field test. Several refinements to the orbit determination strategies were found to be crucial for achieving high levels of repeatability and accuracy. These include the fine tuning of the GPS solar radiation coefficients and the ground station zenith tropospheric delays. Multiday arcs of 3-6 days provided better orbits and baselines than the 8-hr arcs from single-day passes. Highest-quality orbits and baselines were obtained with combined carrier phase and pseudorange solutions.