WorldWideScience

Sample records for position reporting system

  1. Satellite Search and Rescue System Studies: Alarm and Position Reporting.

    Science.gov (United States)

    alarm and position reporting ( ALPR ) techniques, and the operational or planned spacecraft which might be available for piggybacking the ALPR payload...Several system concepts were then developed to perform the ALPR functions. The candidates were screened and the preferred system concepts were chosen

  2. Global Positioning Radiometric Scanner System. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    2001-01-01

    The US DOE continually seeks safer and more cost-effective technologies for use in decontamination and decommissioning (D and D) of nuclear facilities. To this end, the Deactivation and Decommissioning Focus Area (DDFA) of the DOE OST sponsors the Large Scale Demonstration and Deployment Projects (LSDDP). At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE projects and to others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased costs of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) LSDDP generated a list of statements defining specific needs or problems where improved technology could be incorporated into ongoing D and D tasks. One of the stated needs was for developing technologies that would reduce costs and shorten DDOE/EM--0552DOE/EM--0552 and D schedules by providing radiological characterizations to meet the free-release criteria. The Global Positioning Radiometric Scanner (GPRS system shown in Figure 1) utilizes a detection system; a portable computer, a differential global positioning system (d-gps), and a four wheel drive vehicle. Once the survey data has been collected, a software program called GeoSofttrademark generates a graphical representation of the radiological contamination extent. Baseline technology involves gridding the area and hand surveying each grid. This demonstration investigated the associated costs and the required time to evaluate the radiological characterization data from the GPRS with respect to the baseline technology. The GPRS system performs in-situ, real-time analyses to identify the extent of radiological contamination. Benefits expected from using the new innovative technology (GPRS) include: Reduced labor hours associated with performing the survey; Increased number of survey data points; Reduced

  3. Global Positioning System: Observations on Quarterly Reports from the Air Force

    Science.gov (United States)

    2016-10-17

    Positioning System : Observations on Quarterly Reports from the Air Force The satellite-based Global Positioning System (GPS) provides positioning , navigation...infrastructure, and transportation safety. The Department of Defense (DOD)—specifically, the Air Force—develops and operates the GPS system , which...programs, including the most recent detailed assessment of the next generation operational control system (OCX)

  4. Breast calcifications. A standardized mammographic reporting and data system to improve positive predictive value

    International Nuclear Information System (INIS)

    Perugini, G.; Bonzanini, B.; Valentino, C.

    1999-01-01

    The purpose of this work is to investigate the usefulness of a standardized reporting and data system in improving the positive predictive value of mammography in breast calcifications. Using the Breast Imaging Reporting and Data System lexicon developed by the American College of Radiology, it is defined 5 descriptive categories of breast calcifications and classified diagnostic suspicion of malignancy on a 3-grade scale (low, intermediate and high). Two radiologists reviewed 117 mammographic studies selected from those of the patients submitted to surgical biopsy for mammographically detected calcifications from January 1993 to December 1997, and classified them according to the above criteria. The positive predictive value was calculated for all examinations and for the stratified groups. Defining a standardized system for assessing and describing breast calcifications helps improve the diagnostic accuracy of mammography in clinical practice [it

  5. Report to Congress : recapitalization plan for the nationwide differential global positioning system (NDGPS).

    Science.gov (United States)

    2010-06-01

    The U.S. Department of Transportation (DOT) has developed a recpitlaization plan to reduce technical, cost, and programmatic risks of the DOT-funded inland segment of the Nationwide Differential Global Positioning System (NDGPS)

  6. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    Science.gov (United States)

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  7. Transitions in the Swedish school system and the impact on student's positive self-reported-health.

    Science.gov (United States)

    Holmström, Malin Rising; Olofsson, Niclas; Asplund, Kenneth; Kristiansen, Lisbeth

    2014-10-07

    To explore three school based transitions and their impact on positive self-reported-health (SRH), pre-school to elementary school (6-10 y), elementary school to junior high school (10-13 y), and junior high school to upper secondary school/high school (13-16 y), in a long-term longitudinal population based study. The study followed three cohorts through one school transition each. A longitudinal study with data from 6693 Health Dialogue questionnaires were used. Data were collected in the middle of Sweden during 2007-2012 with school children age 6-16 years old. Several significant factors were identified with an impact for a positive self-reported-health among children age 6-16 y; not feeling sad or depressed, afraid or worried, positive school environment (schoolyard and restrooms), not bullied, good sleep, daily physical activity and ability to concentrate. There was no single factor identified, the factors differed according to gender and age. The study have identified several gender and age specific factors for successful school transitions relevant for a positive SRH. This is valuable information for school staff, parents and school children and provides a possibility to provide support and assistance when needed.

  8. Position Ring System using Anger Type Detectors. Progress Report (1999-2002)

    International Nuclear Information System (INIS)

    Karp, Joel S.

    2004-01-01

    The overall objective of our project was to develop PET scanners and imaging techniques that achieve high performance and excellent image quality. Our approach was based upon 3-D imaging (no septa) with position-sensitive Anger-logic detectors, whereby the encoding ratio of resolution elements to number of photo-multiplier tube channels is very high. This design led to a series of PET systems that emphasized cost-effectiveness and practicality in a clinical environment.

  9. Adult systemic Epstein-Barr virus-positive T-cell lymphoproliferative disease: A case report.

    Science.gov (United States)

    Wang, Youping; Liu, Xinyue; Chen, Yan

    2015-09-01

    Systemic Epstein-Barr virus (EBV)-positive T-cell lymphoproliferative disease (EBV + T-LPD) occurs mainly in Asia and South America and is extremely rare in adults. The disease is characterized by a clonal proliferation of EBV-infected T cells with a cytotoxic immunophenotype and is associated with a poor clinical outcome and can be life-threatening. The majority of the patients have evidence of systemic disease, often with lymph node, liver and spleen involvement. The present study describes a case of adult systemic EBV + T-LPD with high fever, systemic lymphadenopathy, hepatosplenomegaly, nose-pharynx neoplasm, pancytopenia, EB virus infection and proliferative bone marrow, with the aim of improving the understanding of the condition.

  10. Position and Orientation Tracking System graphical user interface. CRADA final report

    International Nuclear Information System (INIS)

    Barry, R.E.; Armstrong, G.A.; Burks, B.L.

    1997-01-01

    Under the Department of Energy's Robotics Technology Development Program (RTDP) Tank Waste Retrieval (TWR) program, a major effort is under way to develop technology for remediating the waste in underground storage tanks that contain radioactive and hazardous waste. A large part of the program's effort has gone towards development of remotely operable robotics equipment, including the Houdini Vehicle and the Position and Orientation Tracking System (POTS). Since planned operation of this equipment is to be completely remote, a significant effort is needed to ensure that operators have sufficient system information to operate the equipment efficiently and safely. ORNL developed POTS and RedZone Robotics, Inc. developed Houdini which can be operated together to provide both position and orientation descriptions of the Houdini vehicle, relative to a world reference frame, while operating inside an underground storage tank. The Houdini vehicle has been outfitted with an optical detection system that houses infrared detectors. The infrared detectors are part of the POTS tracking system. The sensors provide a set of timing pulses to the POTS control computer whenever a laser beam from one of the four POTS laser scanners strikes a detector. Using the pointing angle information from each POTS laser scanners, the POTS control computer is able to compute the pose of the Houdini vehicle at a rate of approximately 25 Hz. This information, along with the orientation of the Houdini's Schilling Titan II robot arm, is used to present the pose information to the operator in a 3-D graphical user interface using software that has been developed by this Cooperative Research and Development Agreement (CRADA). The graphical display presents the data to the operator in a format that is readily understood. The equipment operators are able to use the information in real-time to enhance the operator's ability to safely and efficiently control the remotely-operated vehicle

  11. Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68

    International Nuclear Information System (INIS)

    Lightstone, A.W.; Benedict, Stanley H.; Bova, Frank J.; Solberg, Timothy D.; Stern, Robin L.

    2005-01-01

    Intracranial stereotactic positioning systems (ISPSs) are used to position patients prior to precise radiation treatment of localized lesions of the brain. Often, the lesion is located in close proximity to critical anatomic features whose functions should be maintained. Many types of ISPSs have been described in the literature and are commercially available. These are briefly reviewed. ISPS systems provide two critical functions. The first is to establish a coordinate system upon which a guided therapy can be applied. The second is to provide a method to reapply the coordinate system to the patient such that the coordinates assigned to the patient's anatomy are identical from application to application. Without limiting this study to any particular approach to ISPSs, this report introduces nomenclature and suggests performance tests to quantify both the stability of the ISPS to map diagnostic data to a coordinate system, as well as the ISPS's ability to be realigned to the patient's anatomy. For users who desire to develop a new ISPS system, it may be necessary for the clinical team to establish the accuracy and precision of each of these functions. For commercially available systems that have demonstrated an acceptable level of accuracy and precision, the clinical team may need to demonstrate local ability to apply the system in a manner consistent with that employed during the published testing. The level of accuracy and precision required of an individual ISPS system is dependent upon the clinical protocol (e.g., fractionation, margin, pathology, etc.). Each clinical team should provide routine quality assurance procedures that are sufficient to support the assumptions of accuracy and precision used during the planning process. The testing of ISPS systems can be grouped into two broad categories, type testing, which occurs prior to general commercialization, and site testing, performed when a commercial system is installed at a clinic. Guidelines to help select

  12. Triangulation positioning system network

    Directory of Open Access Journals (Sweden)

    Sfendourakis Marios

    2017-01-01

    Full Text Available This paper presents ongoing work on localization and positioning through triangulation procedure for a Fixed Sensors Network - FSN.The FSN has to work as a system.As the triangulation problem becomes high complicated in a case with large numbers of sensors and transmitters, an adequate grid topology is needed in order to tackle the detection complexity.For that reason a Network grid topology is presented and areas that are problematic and need further analysis are analyzed.The Network System in order to deal with problems of saturation and False Triangulations - FTRNs will have to find adequate methods in every sub-area of the Area Of Interest - AOI.Also, concepts like Sensor blindness and overall Network blindness, are presented. All these concepts affect the Network detection rate and its performance and ought to be considered in a way that the network overall performance won’t be degraded.Network performance should be monitored contentiously, with right algorithms and methods.It is also shown that as the number of TRNs and FTRNs is increased Detection Complexity - DC is increased.It is hoped that with further research all the characteristics of a triangulation system network for positioning will be gained and the system will be able to perform autonomously with a high detection rate.

  13. 5th International Symposium on Positive Systems

    CERN Document Server

    Farina, Lorenzo; Setola, Roberto; Germani, Alfredo

    2017-01-01

    This book presents high-quality original contributions on positive systems, including topics such as: monotone dynamical systems in mathematical biology and game theory; mathematical developments for networked systems in biology, chemistry and the social sciences; linear and nonlinear positive operators; dynamical analysis, observation and control of positive distributed parameter systems; stochastic realization theory; biological systems with positive variables and positive controls; iterated function systems; nonnegative dynamic processes; and dimensioning problems for collaborative systems. The book comprises a selection of the best papers presented at the POSTA 2016, the 5th International Symposium on Positive Systems, which was held in Rome, Italy, in September 2016. This conference series represents a targeted response to the growing need for research that reports on and critically discusses a wide range of topics concerning the theory and applications of positive systems.

  14. Indoor Positioning System using Bluetooth

    OpenAIRE

    Sahil Puri

    2015-01-01

    This Paper on Bluetooth Indoor Positioning System is the intersection of Bluetooth Technology and Indoor Positioning Systems. Almost every smartphone today is Bluetooth enabled, making the use of the technology more flexible. We aim at using the RSSI value of Bluetooth signals to track the location of a device.

  15. Transitions in the Swedish school system and the impact on student’s positive self-reported-health

    OpenAIRE

    Holmström, Malin Rising; Olofsson, Niclas; Asplund, Kenneth; Kristiansen, Lisbeth

    2014-01-01

    Background To explore three school based transitions and their impact on positive self- reported- health (SRH), pre-school to elementary school (6–10 y), elementary school to junior high school (10-13y), and junior high school to upper secondary school/high school (13-16y), in a long-term longitudinal population based study. Methods The study followed three cohorts through one school transition each. A longitudinal study with data from 6693 Health Dialogue questionnaires were used. Data were ...

  16. Antiproton source beam position system

    International Nuclear Information System (INIS)

    Bagwell, T.; Holmes, S.; McCarthy, J.; Webber, R.

    1984-05-01

    The TeV I Beam Position Monitor (BPM) system is designed to provide a useful diagnostic tool during the commissioning and operational phases of the antiproton source. Simply stated the design goal is to provide single turn position information for intensities of > 1x10 9 particles, and multi-turn (clocked orbit) information for beam intensities of > 1x10 7 particles, both with sub-millimeter resolution. It is anticipated that the system will be used during commissioning for establishing the first turn through the Debuncher and Accumulator, for aligning injection orbits, for providing information necessary to correct closed orbits, and for measuring various machine parameters (e.g. tunes, dispersion, aperture, chromaticity). During normal antiproton operation the system will be used to monitor the beam position throughout the accumulation process

  17. Comparison of global positioning system (GPS) tracking and parent-report diaries to characterize children's time-location patterns.

    Science.gov (United States)

    Elgethun, Kai; Yost, Michael G; Fitzpatrick, Cole T E; Nyerges, Timothy L; Fenske, Richard A

    2007-03-01

    Respondent error, low resolution, and study participant burden are known limitations of diary timelines used in exposure studies such as the National Human Exposure Assessment Survey (NHEXAS). Recent advances in global positioning system (GPS) technology have produced tracking devices sufficiently portable, functional and affordable to utilize in exposure assessment science. In this study, a differentially corrected GPS (dGPS) tracking device was compared to the NHEXAS diary timeline. The study also explored how GPS can be used to evaluate and improve such diary timelines by determining which location categories and which respondents are least likely to record "correct" time-location responses. A total of 31 children ages 3-5 years old wore a dGPS device for all waking hours on a weekend day while their parents completed the NHEXAS diary timeline to document the child's time-location pattern. Parents misclassified child time-location approximately 48% of the time using the NHEXAS timeline in comparison to dGPS. Overall concordance between methods was marginal (kappa=0.33-0.35). The dGPS device found that on average, children spent 76% of the 24-h study period in the home. The diary underestimated time the child spent in the home by 17%, while overestimating time spent inside other locations, outside at home, outside in other locations, and time spent in transit. Diary data for time spent outside at home and time in transit had the lowest response concordance with dGPS. The diaries of stay-at-home mothers and mothers working unskilled labor jobs had lower concordance with dGPS than did those of the other participants. The ability of dGPS tracking to collect continuous rather than categorical (ordinal) data was also demonstrated. It is concluded that automated GPS tracking measurements can improve the quality and collection efficiency of time-location data in exposure assessment studies, albeit for small cohorts.

  18. 14 CFR 99.15 - Position reports.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Position reports. 99.15 Section 99.15 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.15 Position reports. (a) The...

  19. Relativistic positioning systems: Numerical simulations

    Science.gov (United States)

    Puchades Colmenero, Neus

    The position of users located on the Earth's surface or near it may be found with the classic positioning systems (CPS). Certain information broadcast by satellites of global navigation systems, as GPS and GALILEO, may be used for positioning. The CPS are based on the Newtonian formalism, although relativistic post-Newtonian corrections are done when they are necessary. This thesis contributes to the development of a different positioning approach, which is fully relativistic from the beginning. In the relativistic positioning systems (RPS), the space-time position of any user (ship, spacecraft, and so on) can be calculated with the help of four satellites, which broadcast their proper times by means of codified electromagnetic signals. In this thesis, we have simulated satellite 4-tuples of the GPS and GALILEO constellations. If a user receives the signals from four satellites simultaneously, the emission proper times read -after decoding- are the user "emission coordinates". In order to find the user "positioning coordinates", in an appropriate almost inertial reference system, there are two possibilities: (a) the explicit relation between positioning and emission coordinates (broadcast by the satellites) is analytically found or (b) numerical codes are designed to calculate the positioning coordinates from the emission ones. Method (a) is only viable in simple ideal cases, whereas (b) allows us to consider realistic situations. In this thesis, we have designed numerical codes with the essential aim of studying two appropriate RPS, which may be generalized. Sometimes, there are two real users placed in different positions, which receive the same proper times from the same satellites; then, we say that there is bifurcation, and additional data are needed to choose the real user position. In this thesis, bifurcation is studied in detail. We have analyzed in depth two RPS models; in both, it is considered that the satellites move in the Schwarzschild's space

  20. Position and orientation tracking system

    International Nuclear Information System (INIS)

    Burks, B.L.; DePiero, F.W.; Armstrong, G.A.; Jansen, J.F.; Muller, R.C.; Gee, T.F.

    1998-01-01

    A position and orientation tracking system presents a laser scanning apparatus having two measurement pods, a control station, and a detector array. The measurement pods can be mounted in the dome of a radioactive waste storage silo. Each measurement pod includes dual orthogonal laser scanner subsystems. The first laser scanner subsystem is oriented to emit a first line laser in the pan direction. The second laser scanner is oriented to emit a second line laser in the tilt direction. Both emitted line lasers scan planes across the radioactive waste surface to encounter the detector array mounted on a target robotic vehicle. The angles of incidence of the planes with the detector array are recorded by the control station. Combining measurements describing each of the four planes provides data for a closed form solution of the algebraic transform describing the position and orientation of the target robotic vehicle. 14 figs

  1. The Global Positioning System: Theory and operation

    Science.gov (United States)

    Tucker, Lester Plunkett

    Scope and method of study. The purpose of this study is to document the theory, development, and training needs of the United States Global Positioning System for the United States Air Force. This subject area had very little information and to assess the United States Air Force training needs required an investigation into existing training accomplished on the Global Positioning System. The United States Air Force has only one place to obtain the data at Headquarters Air Education and Training Command. Findings and conclusion. The United States Air Force, at the time of this study, does not have a theory and operations course dealing with the newest technology advancement in world navigation. Although this new technology is being provided on aircraft in the form of new navigation hardware, no official course of study is provided by the United States Air Force to it's pilots and navigators dealing with theory and operation. Based on the latest reports dealing with the Global Positioning System, a course on the Global Positioning System was developed in the Instructional Systems Design format to provide background information and understanding of this new technology. Readers of this study must be aware that the information contained in this study is very dynamic. Technology is advancing so fast in this area that it might make this information obsolete in a short amount of time.

  2. Positioning performance of a maglev fine positioning system

    Energy Technology Data Exchange (ETDEWEB)

    Wronosky, J.B.; Smith, T.G.; Jordan, J.D.; Darnold, J.R.

    1996-12-01

    A wafer positioning system was recently developed by Sandia National Laboratories for an Extreme Ultraviolet Lithography (EUVL) research tool. The system, which utilizes a magnetically levitated fine stage to provide ultra-precise positioning in all six degrees of freedom, incorporates technological improvements resulting from four years of prototype development experience. System enhancements, implemented on a second generation design for an ARPA National Center for Advanced Information Component Manufacturing (NCAICM) project, introduced active structural control for the levitated structure of the system. Magnetic levitation (maglev) is emerging as an important technology for wafer positioning systems in advanced lithography applications. The advantages of maglev stem from the absence of physical contact. The resulting lack of friction enables accurate, fast positioning. Maglev systems are mechanically simple, accomplishing full six degree-of-freedom suspension and control with a minimum of moving parts. Power-efficient designs, which reduce the possibility of thermal distortion of the platen, are achievable. Manufacturing throughput will be improved in future systems with the addition of active structural control of the positioning stages. This paper describes the design, implementation, and functional capability of the maglev fine positioning system. Specifics regarding performance design goals and test results are presented.

  3. Item Banks for Substance Use from the Patient-Reported Outcomes Measurement Information System (PROMIS®): Severity of Use and Positive Appeal of Use*

    Science.gov (United States)

    Pilkonis, Paul A.; Yu, Lan; Dodds, Nathan E.; Johnston, Kelly L.; Lawrence, Suzanne; Hilton, Thomas F.; Daley, Dennis C.; Patkar, Ashwin A.; McCarty, Dennis

    2015-01-01

    Background Two item banks for substance use were developed as part of the Patient-Reported Outcomes Measurement Information System (PROMIS®): severity of substance use and positive appeal of substance use. Methods Qualitative item analysis (including focus groups, cognitive interviewing, expert review, and item revision) reduced an initial pool of more than 5,300 items for substance use to 119 items included in field testing. Items were written in a first-person, past-tense format, with 5 response options reflecting frequency or severity. Both 30-day and 3-month time frames were tested. The calibration sample of 1,336 respondents included 875 individuals from the general population (ascertained through an internet panel) and 461patients from addiction treatment centers participating in the National Drug Abuse Treatment Clinical Trials Network. Results Final banks of 37 and 18 items were calibrated for severity of substance use and positive appeal of substance use, respectively, using the two-parameter graded response model from item response theory (IRT). Initial calibrations were similar for the 30-day and 3-month time frames, and final calibrations used data combined across the time frames, making the items applicable with either interval. Seven-item static short forms were also developed from each item bank. Conclusions Test information curves showed that the PROMIS item banks provided substantial information in a broad range of severity, making them suitable for treatment, observational, and epidemiological research in both clinical and community settings. PMID:26423364

  4. Daresbury SRS Positional Feedback Systems

    CERN Document Server

    Smith, S L

    2000-01-01

    The Daresbury SRS is a second generation synchrotron radiation source which ramps from its injection energy of 600 MeV to 2.0 GeV. Beam orbit feedback systems have been in routine operation on the SRS since 1994 and are now an essential element in delivering stable photon beams to experimental stations. The most recent enhancements to these systems have included the introduction of a ramp servo system to provide the orbit control demanded by the installation of two new narrow gap insertion device and development of the vertical orbit feedback system to cope with an increasing number of photon beamlines. This paper summaries the current status of these systems and briefly discusses proposed developments.

  5. Positive real balancing for nonlinear systems

    NARCIS (Netherlands)

    Ionescu, Tudor C.; Scherpen, Jacquelien M.A.; Ciuprina, G; Ioan, D

    2007-01-01

    We extend the positive real balancing procedure for passive linear systems to the nonlinear systems case. We show that, just like in the linear case, model reduction based on this technique preserves passivity.

  6. a Continuous-Time Positive Linear System

    Directory of Open Access Journals (Sweden)

    Kyungsup Kim

    2013-01-01

    Full Text Available This paper discusses a computational method to construct positive realizations with sparse matrices for continuous-time positive linear systems with multiple complex poles. To construct a positive realization of a continuous-time system, we use a Markov sequence similar to the impulse response sequence that is used in the discrete-time case. The existence of the proposed positive realization can be analyzed with the concept of a polyhedral convex cone. We provide a constructive algorithm to compute positive realizations with sparse matrices of some positive systems under certain conditions. A sufficient condition for the existence of a positive realization, under which the proposed constructive algorithm works well, is analyzed.

  7. Platform Architecture for Decentralized Positioning Systems

    Directory of Open Access Journals (Sweden)

    Zakaria Kasmi

    2017-04-01

    Full Text Available A platform architecture for positioning systems is essential for the realization of a flexible localization system, which interacts with other systems and supports various positioning technologies and algorithms. The decentralized processing of a position enables pushing the application-level knowledge into a mobile station and avoids the communication with a central unit such as a server or a base station. In addition, the calculation of the position on low-cost and resource-constrained devices presents a challenge due to the limited computing, storage capacity, as well as power supply. Therefore, we propose a platform architecture that enables the design of a system with the reusability of the components, extensibility (e.g., with other positioning technologies and interoperability. Furthermore, the position is computed on a low-cost device such as a microcontroller, which simultaneously performs additional tasks such as data collecting or preprocessing based on an operating system. The platform architecture is designed, implemented and evaluated on the basis of two positioning systems: a field strength system and a time of arrival-based positioning system.

  8. Relativistic positioning systems: perspectives and prospects

    Science.gov (United States)

    Coll Bartolomé

    2013-11-01

    Relativistic positioning systems are interesting technical objects for applications around the Earth and in the Solar system. But above all else, they are basic scientific objects allowing developing relativity from its own concepts. Some past and future features of relativistic positioning sys- tems, with special attention to the developments that they suggest for an epistemic relativity (relativistic experimental approach to physics), are analyzed. This includes relativistic stereometry, which, together with relativistic positioning systems, allows to introduce the general relativistic notion of (finite) laboratory (space-time region able to perform experiments of finite size).

  9. Positional reference system for ultraprecision machining

    Science.gov (United States)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  10. Positional reference system for ultraprecision machining

    International Nuclear Information System (INIS)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1982-01-01

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlledmultiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base

  11. The Mathematics of the Global Positioning System.

    Science.gov (United States)

    Nord, Gail D.; Jabon, David; Nord, John

    1997-01-01

    Presents an activity that illustrates the application of mathematics to modern navigation and utilizes the Global Positioning System (GPS). GPS is a constellation of 24 satellites that enables receivers to compute their position anywhere on the earth with great accuracy. (DDR)

  12. Linear quadratic optimization for positive LTI system

    Science.gov (United States)

    Muhafzan, Yenti, Syafrida Wirma; Zulakmal

    2017-05-01

    Nowaday the linear quadratic optimization subject to positive linear time invariant (LTI) system constitute an interesting study considering it can become a mathematical model of variety of real problem whose variables have to nonnegative and trajectories generated by these variables must be nonnegative. In this paper we propose a method to generate an optimal control of linear quadratic optimization subject to positive linear time invariant (LTI) system. A sufficient condition that guarantee the existence of such optimal control is discussed.

  13. Exponential Stability of Switched Positive Homogeneous Systems

    Directory of Open Access Journals (Sweden)

    Dadong Tian

    2017-01-01

    Full Text Available This paper studies the exponential stability of switched positive nonlinear systems defined by cooperative and homogeneous vector fields. In order to capture the decay rate of such systems, we first consider the subsystems. A sufficient condition for exponential stability of subsystems with time-varying delays is derived. In particular, for the corresponding delay-free systems, we prove that this sufficient condition is also necessary. Then, we present a sufficient condition of exponential stability under minimum dwell time switching for the switched positive nonlinear systems. Some results in the previous literature are extended. Finally, a numerical example is given to demonstrate the effectiveness of the obtained results.

  14. Position and orientation determination system and method

    Science.gov (United States)

    Harpring, Lawrence J.; Farfan, Eduardo B.; Gordon, John R.; Jannik, Gerald T.; Foley, Trevor Q.

    2017-06-14

    A position determination system and method is provided that may be used for obtaining position and orientation information of a detector in a contaminated room. The system includes a detector, a sensor operably coupled to the detector, and a motor coupled to the sensor to move the sensor around the detector. A CPU controls the operation of the motor to move the sensor around the detector and determines distance and angle data from the sensor to an object. The method includes moving a sensor around the detector and measuring distance and angle data from the sensor to an object at incremental positions around the detector.

  15. Stabilization of discrete-time LTI positive systems

    Directory of Open Access Journals (Sweden)

    Krokavec Dušan

    2017-12-01

    Full Text Available The paper mitigates the existing conditions reported in the previous literature for control design of discrete-time linear positive systems. Incorporating an associated structure of linear matrix inequalities, combined with the Lyapunov inequality guaranteing asymptotic stability of discrete-time positive system structures, new conditions are presented with which the state-feedback controllers and the system state observers can be designed. Associated solutions of the proposed design conditions are illustrated by numerical illustrative examples.

  16. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  17. Marketing reporting system

    OpenAIRE

    Hanić Hasan M.

    2004-01-01

    The main components of a developed and good organized marketing information system are: internal reporting system, marketing reporting system, market research system and analytical marketing system. Marketing reporting system provides data and information about changes in business and micro marketing environment. This component of MIS ensures that marketing managers are up-to-date with what is going on, and to be informed about changes in company marketing environment.

  18. Marketing reporting system

    Directory of Open Access Journals (Sweden)

    Hanić Hasan M.

    2004-01-01

    Full Text Available The main components of a developed and good organized marketing information system are: internal reporting system, marketing reporting system, market research system and analytical marketing system. Marketing reporting system provides data and information about changes in business and micro marketing environment. This component of MIS ensures that marketing managers are up-to-date with what is going on, and to be informed about changes in company marketing environment.

  19. Modular Track System For Positioning Mobile Robots

    Science.gov (United States)

    Miller, Jeff

    1995-01-01

    Conceptual system for positioning mobile robotic manipulators on large main structure includes modular tracks and ancillary structures assembled easily along with main structure. System, called "tracked robotic location system" (TROLS), originally intended for application to platforms in outer space, but TROLS concept might also prove useful on Earth; for example, to position robots in factories and warehouses. T-cross-section rail keeps mobile robot on track. Bar codes mark locations along track. Each robot equipped with bar-code-recognizing circuitry so it quickly finds way to assigned location.

  20. The AGS Booster Beam Position Monitor system

    International Nuclear Information System (INIS)

    Ciardullo, D.J.; Abola, A.; Beadle, E.R.; Smith, G.A.; Thomas, R.; Van Zwienen, W.; Warkentien, R.; Witkover, R.L.

    1991-01-01

    To accelerate both protons and heavy ions, the AGS Booster requires a broadband (multi-octave) beam position monitoring system with a dynamic range spanning several orders of magnitude (2 x 10 10 to 1.5 x 10 13 particles per pulse). System requirements include the ability to acquire single turn trajectory and average orbit information with ± 0.1 mm resolution. The design goal of ± 0.5 mm corrected accuracy requires that the detectors have repeatable linear performance after periodic bakeout at 300 degree C. The system design and capabilities of the Booster Beam Position Monitor will be described, and initial results presented. 7 refs., 5 figs

  1. Airborne relay-based regional positioning system.

    Science.gov (United States)

    Lee, Kyuman; Noh, Hongjun; Lim, Jaesung

    2015-05-28

    Ground-based pseudolite systems have some limitations, such as low vertical accuracy, multipath effects and near-far problems. These problems are not significant in airborne-based pseudolite systems. However, the monitoring of pseudolite positions is required because of the mobility of the platforms on which the pseudolites are mounted, and this causes performance degradation. To address these pseudolite system limitations, we propose an airborne relay-based regional positioning system that consists of a master station, reference stations, airborne relays and a user. In the proposed system, navigation signals are generated from the reference stations located on the ground and are relayed via the airborne relays. Unlike in conventional airborne-based systems, the user in the proposed system sequentially estimates both the locations of airborne relays and his/her own position. Therefore, a delay due to monitoring does not occur, and the accuracy is not affected by the movement of airborne relays. We conducted several simulations to evaluate the performance of the proposed system. Based on the simulation results, we demonstrated that the proposed system guarantees a higher accuracy than airborne-based pseudolite systems, and it is feasible despite the existence of clock offsets among reference stations.

  2. PLS beam position measurement and feedback system

    International Nuclear Information System (INIS)

    Huang, J.Y.; Lee, J.; Park, M.K.; Kim, J.H.; Won, S.C.

    1992-01-01

    A real-time orbit correction system is proposed for the stabilization of beam orbit and photon beam positions in Pohang Light Source. PLS beam position monitoring system is designed to be VMEbus compatible to fit the real-time digital orbit feedback system. A VMEbus based subsystem control computer, Mil-1553B communication network and 12 BPM/PS machine interface units constitute digital part of the feedback system. With the super-stable PLS correction magnet power supply, power line frequency noise is almost filtered out and the dominant spectra of beam obtit fluctuations are expected to appear below 15 Hz. Using DSP board in SCC for the computation and using an appropriate compensation circuit for the phase delay by the vacuum chamber, PLS real-time orbit correction system is realizable without changing the basic structure of PLS computer control system. (author)

  3. Ad-Coop Positioning System (ACPS)

    DEFF Research Database (Denmark)

    Frattasi, Simone; Monti, Marco

    2008-01-01

    In this paper, we propose an innovative solution for positioning determination in 4G wireless networks by introducing the Ad-Coop Positioning System (ACPS). The ACPS is supported by a hybrid cellular ad-hoc architecture, where the cellular network has a centralized control over the ad-hoc connect......In this paper, we propose an innovative solution for positioning determination in 4G wireless networks by introducing the Ad-Coop Positioning System (ACPS). The ACPS is supported by a hybrid cellular ad-hoc architecture, where the cellular network has a centralized control over the ad...... method for the ACPS, which appropriately combines and weights the long- and short-range location information in a non-linear least square (NLLS) minimization procedure. The numerical results shown in the paper demonstrate that the ACPS enhances the location estimation accuracy with respect...

  4. PHYSICS UPDATE: The global positioning system

    Science.gov (United States)

    Walton, Alan J.; Black, Richard J.

    1999-01-01

    A hand-held global positioning system receiver displays the operator's latitude, longitude and velocity. Knowledge of GCSE-level physics will allow the basic principles of the system to be understood; knowledge of A-level physics will allow many important aspects of their implementation to be comprehended. A discussion of the system provides many simple numerical calculations relevant to school and first-year undergraduate syllabuses.

  5. Navigation and Positioning System Using High Altitude Platforms Systems (HAPS)

    Science.gov (United States)

    Tsujii, Toshiaki; Harigae, Masatoshi; Harada, Masashi

    Recently, some countries have begun conducting feasibility studies and R&D projects on High Altitude Platform Systems (HAPS). Japan has been investigating the use of an airship system that will function as a stratospheric platform for applications such as environmental monitoring, communications and broadcasting. If pseudolites were mounted on the airships, their GPS-like signals would be stable augmentations that would improve the accuracy, availability, and integrity of GPS-based positioning systems. Also, the sufficient number of HAPS can function as a positioning system independent of GPS. In this paper, a system design of the HAPS-based positioning system and its positioning error analyses are described.

  6. An interactive beam position monitor system simulator

    International Nuclear Information System (INIS)

    Ryan, W.A.; Shea, T.J.

    1993-03-01

    A system simulator has been implemented to aid the development of the RHIC position monitor system. Based on the LabVIEW software package by National Instruments, this simulator allows engineers and technicians to interactively explore the parameter space of a system during the design phase. Adjustable parameters are divided into three categories: beam, pickup, and electronics. The simulator uses these parameters in simple formulas to produce results in both time-domain and frequencydomain. During the prototyping phase, these simulated results can be compared to test data acquired with the same software package. The RHIC position monitor system is presented as an example, but the software is applicable to several other systems as well

  7. Application of the NAVSTAR/GLOBAL positioning system on instrumented ranges

    OpenAIRE

    Reinhart, William L.

    1981-01-01

    Approved for public release; distribution is unlimited This report treats the application of the NAVSTAR/Global Positioning System as the Position/Location System in Real Time Casualty Assessment experiments. The desirable characteristics of a position/location system are listed. A current position/location system, the Range Measuring System, is used as a comparison reference for the Global Positioning System. Operation and parameters of the Global Positioning System are presented. A d...

  8. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  9. Beam position monitor system for storage rings

    International Nuclear Information System (INIS)

    Nakamura, M.; Hinkson, J.A.

    1985-05-01

    Beam position monitors (BPM) for synchrotron light storage rings usually consist of beam pickup electrodes, coaxial relays and a narrowband receiver. While accurate, these systems are slow and of limited use in the commissioning of an accelerator. A beam position monitor is described which is intended to be a principal diagnostic during debug and routine running of a storage ring. It is capable of measuring the position of a single bunch on the first or nth orbit to an accuracy of a few percent. Stored beam position is more accurately measured with averaging techniques. Beam position changes can be studied in a bandwidth from DC to a few MHz. The beam monitor electronics consist of a separate amplification, detection, and sampling channel for each beam pickup electrode. Fast switches in each channel permit selection of the nth turn for measurement (single bunch mode). A calibration pulse is injected into each channel after beam measurement to permit gain offsets to be measured and removed from the final data. While initially more costly than the usual beam position monitor system, this sytem will pay for itself in reduced storage ring debug and trouble shooting time. 5 refs., 5 figs

  10. Position paper - primary ventilation system configuration

    International Nuclear Information System (INIS)

    Dalpiaz, E.L.

    1994-06-01

    The purpose of this paper is to develop and document a position on the configuration of the primary ventilation system. This configuration will be used on the waste storage tanks currently being designed for the Multi-Function Waste Tank Facility. The primary ventilation system provides a single treatment train and exhaust fan for each waste storage tank. The ventilation systems from each of two tanks are grouped with an additional treatment train and exhaust fan that function as backup to either of the two systems

  11. A Study of Vicon System Positioning Performance

    Directory of Open Access Journals (Sweden)

    Pierre Merriaux

    2017-07-01

    Full Text Available Motion capture setups are used in numerous fields. Studies based on motion capture data can be found in biomechanical, sport or animal science. Clinical science studies include gait analysis as well as balance, posture and motor control. Robotic applications encompass object tracking. Today’s life applications includes entertainment or augmented reality. Still, few studies investigate the positioning performance of motion capture setups. In this paper, we study the positioning performance of one player in the optoelectronic motion capture based on markers: Vicon system. Our protocol includes evaluations of static and dynamic performances. Mean error as well as positioning variabilities are studied with calibrated ground truth setups that are not based on other motion capture modalities. We introduce a new setup that enables directly estimating the absolute positioning accuracy for dynamic experiments contrary to state-of-the art works that rely on inter-marker distances. The system performs well on static experiments with a mean absolute error of 0.15 mm and a variability lower than 0.025 mm. Our dynamic experiments were carried out at speeds found in real applications. Our work suggests that the system error is less than 2 mm. We also found that marker size and Vicon sampling rate must be carefully chosen with respect to the speed encountered in the application in order to reach optimal positioning performance that can go to 0.3 mm for our dynamic study.

  12. 33 CFR 161.20 - Position Report (PR).

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Position Report (PR). 161.20 Section 161.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Report (PR). A vessel must report its name and position: (a) Upon point of entry into a VMRS area; (b) At...

  13. Towards a Decentralized Magnetic Indoor Positioning System

    Science.gov (United States)

    Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg

    2015-01-01

    Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters. PMID:26690145

  14. Towards a Decentralized Magnetic Indoor Positioning System

    Directory of Open Access Journals (Sweden)

    Zakaria Kasmi

    2015-12-01

    Full Text Available Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS, thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters.

  15. Impulse position control algorithms for nonlinear systems

    Energy Technology Data Exchange (ETDEWEB)

    Sesekin, A. N., E-mail: sesekin@list.ru [Ural Federal University, 19 S. Mira, Ekaterinburg, 620002 (Russian Federation); Institute of Mathematics and Mechanics, Ural Division of Russian Academy of Sciences, 16 S. Kovalevskaya, Ekaterinburg, 620990 (Russian Federation); Nepp, A. N., E-mail: anepp@urfu.ru [Ural Federal University, 19 S. Mira, Ekaterinburg, 620002 (Russian Federation)

    2015-11-30

    The article is devoted to the formalization and description of impulse-sliding regime in nonlinear dynamical systems that arise in the application of impulse position controls of a special kind. The concept of trajectory impulse-sliding regime formalized as some limiting network element Euler polygons generated by a discrete approximation of the impulse position control This paper differs from the previously published papers in that it uses a definition of solutions of systems with impulse controls, it based on the closure of the set of smooth solutions in the space of functions of bounded variation. The need for the study of such regimes is the fact that they often arise when parry disturbances acting on technical or economic control system.

  16. Impulse position control algorithms for nonlinear systems

    Science.gov (United States)

    Sesekin, A. N.; Nepp, A. N.

    2015-11-01

    The article is devoted to the formalization and description of impulse-sliding regime in nonlinear dynamical systems that arise in the application of impulse position controls of a special kind. The concept of trajectory impulse-sliding regime formalized as some limiting network element Euler polygons generated by a discrete approximation of the impulse position control This paper differs from the previously published papers in that it uses a definition of solutions of systems with impulse controls, it based on the closure of the set of smooth solutions in the space of functions of bounded variation. The need for the study of such regimes is the fact that they often arise when parry disturbances acting on technical or economic control system.

  17. Global Positioning System receiver evaluation results

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, R.H.

    1993-09-01

    A Sandia project currently uses an outdated Magnavox 6400 Global Positioning System (GPS) receiver as the core of its navigation system. The goal of this study was to analyze the performance of the current GPS receiver compared to newer, less expensive models and to make recommendations on how to improve the performance of the overall navigation system. This paper discusses the test methodology used to experimentally analyze the performance of different GPS receivers, the test results, and recommendations on how an upgrade should proceed. Appendices contain detailed information regarding the raw data, test hardware, and test software.

  18. National Outbreak Reporting System

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Outbreak Reporting System (NORS) is a web-based platform designed to support reporting to CDC by local, state, and territorial health departments in the...

  19. Bluetooth Indoor Positioning System using Fingerprinting

    DEFF Research Database (Denmark)

    Frost, Christian; Jensen, Casper Svenning; Luckow, Kasper Søe

    2011-01-01

    Indoor Positioning has been an active research area in the last decade, but so far, commercial Indoor Positioning Systems (IPSs) have been sparse. The main obstacle towards widely available IPSs has been the lack of appropriate, low cost technologies, that enable indoor positioning. While Wi-Fi...... infrastructures are ubiquitous, consumer-oriented Wi-Fi enabled mobile phones have been missing. Conversely, while Bluetooth technology is present in the vast majority of consumer mobile phones, Bluetooth infrastructures have been missing. Bluetooth infrastructures have typically been installed as part...... of complete hardware/software IPSs that often incur a substantial hardware cost. Furthermore, Bluetooth has low power consumption compared to Wi-Fi devices, which promotes longer battery life-time on mobile phones. In this paper, we present a Bluetooth IPS based entirely on commodity-grade products...

  20. Integrated Reporting Information System -

    Data.gov (United States)

    Department of Transportation — The Integrated Reporting Information System (IRIS) is a flexible and scalable web-based system that supports post operational analysis and evaluation of the National...

  1. Deceleration system for kinematic linkages of positioning

    Science.gov (United States)

    Stan, G.

    2017-08-01

    Flexible automation is used more and more in various production processes, so that both machining itself on CNC machine tools and workpiece handling means are performed through programming the needed working cycle. In order to obtain a successful precise positioning, each motion degree needs a certain deceleration before stopping at a programmed point. The increase of motion speed of moving elements within the manipulators structure depends directly on deceleration duty quality before the programmed stop. Proportional valves as well as servo-valves that can perform hydraulic decelerations are well known, but they feature several disadvantages, such as: high price, severe conditions for oil filtering and low reliability under industrial conditions. This work presents a new deceleration system that allows adjustment of deceleration slope according to actual conditions: inertial mass, speed etc. The new solution of hydraulic decelerator allows its integration to a position loop or its usage in case of positioning large elements that only perform fixed cycles. The results being obtained on the positioning accuracy of a linear axis using the new solution of the hydraulic decelerator are presented, too. The price of the new deceleration system is much lower compared to the price of proportional valves or servo-valves.

  2. a positive control plasmid for reporter gene assay

    African Journals Online (AJOL)

    STORAGESEVER

    2008-07-04

    Jul 4, 2008 ... qualification as a positive control for luciferase reporter gene assays. Key words: Reporter gene plasmid, luciferase assay, cytomegalovirus promoter/enhancer, human melanoma cell line. INTRODUCTION. Reporter genes, often called reporters, have become a precious tool in studies of gene expression ...

  3. Local Positioning Systems in (Game) Sports

    Science.gov (United States)

    Leser, Roland; Baca, Arnold; Ogris, Georg

    2011-01-01

    Position data of players and athletes are widely used in sports performance analysis for measuring the amounts of physical activities as well as for tactical assessments in game sports. However, positioning sensing systems are applied in sports as tools to gain objective information of sports behavior rather than as components of intelligent spaces (IS). The paper outlines the idea of IS for the sports context with special focus to game sports and how intelligent sports feedback systems can benefit from IS. Henceforth, the most common location sensing techniques used in sports and their practical application are reviewed, as location is among the most important enabling techniques for IS. Furthermore, the article exemplifies the idea of IS in sports on two applications. PMID:22163725

  4. Robust Solar Position Sensor for Tracking Systems

    DEFF Research Database (Denmark)

    Ritchie, Ewen; Argeseanu, Alin; Leban, Krisztina Monika

    2009-01-01

    The paper proposes a new solar position sensor used in tracking system control. The main advantages of the new solution are the robustness and the economical aspect. Positioning accuracy of the tracking system that uses the new sensor is better than 1°. The new sensor uses the ancient principle...... of the solar clock. The sensitive elements are eight ordinary photo-resistors. It is important to note that all the sensors are not selected simultaneously. It is not necessary for sensor operating characteristics to be quasi-identical because the sensor principle is based on extreme operating duty measurement...... (bright or dark). In addition, the proposed solar sensor significantly simplifies the operation of the tracking control device....

  5. Primary central nervous system plasmablastic lymphoma presenting in human immunodeficiency virus-negative but Epstein-Barr virus-positive patient: A case report

    Directory of Open Access Journals (Sweden)

    Zhang Li

    2012-05-01

    Full Text Available Abstract We report a 32-year-old Outer Mongolian man, with plasmablastic lymphoma (PBL primarily occured in the central nervous system and diagnosed by surgical resection. This patient appeared headache and Magnetic resonance imaging (MRI showed multiple lesions in the right cerebral hemisphere including the right frontal-parietal lobe and right basal ganglia and the left cerebellum, he was diagnosed as lymphoma by stereotactic biopsy in January 2009 in local hospital, and was given radiotherapy 33 times after the biopsy. The patient was admitted to The Military General Hospital of Beijing PLA., Beijing, P.R. China on March 9th, 2011, with chief complaints of right limbs convulsioned suddenly, then fell down and lose of his consciousness, then awoke after 4 to 5 minutes, with symptoms of angulus oris numbness and the right upper limb powerless ten days ago. MRI of the brain revealed a well-defined hyperdense and enhancing mass in the left frontal-parietal lobe, the meninges are closely related, there was extensive peritumoural edema noted with pressure effects, as evident by effacement of the left lateral ventricles and a 0.5 cm shift of the midline to the right side. Surgical resection showed markedly atypical, large singly dispersed or cohesive proliferation of plasmacytoid cells with frequent abnormal mitoses and binucleation, some neoplastic cells were large with round or oval nuclei and showed coarse chromatin and smaller or unapparent nucleoli, some neoplastic cells with prominent nucleoli, apoptosis and necrosis were often presented. Immunohistochemistry staining and gene rearrangement together with other supportive investigation confirmed the diagnosis of primary central nervous system plasmablastic lymphoma. A month later, he was started on chemotherapy with R-CHOP (rituximab, cyclophosphamide, doxorubicin, leurocristime and prednisone for a week. Other supportive treatment was provided for symptomatic epilepsy. The patient regained

  6. Position Ring System using Anger Type Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Joel S. Karp, principal investigator

    2004-12-14

    The overall objective of our project was to develop PET scanners and imaging techniques that achieve high performance and excellent image quality. Our approach was based upon 3-D imaging (no septa) with position-sensitive Anger-logic detectors, whereby the encoding ratio of resolution elements to number of photo-multiplier tube channels is very high. This design led to a series of PET systems that emphasized cost-effectiveness and practicality in a clinical environment.

  7. Long range position and orientation tracking system

    International Nuclear Information System (INIS)

    Armstrong, G.A.; Jansen, J.F.; Burks, B.L.; Bernacki, B.E.; Nypaver, D.J.

    1995-01-01

    The long range position and orientation tracking system (LRPOTS) will consist of two measurement pods, a VME-based computer system, and a detector array. The system is used to measure the position and orientation of a target that may be attached to a robotic arm, teleoperated manipulator, or autonomous vehicle. The pods have been designed to be mounted in the man-ways of the domes of the Fernald K-65 waste silos. Each pod has two laser scanner subsystems as well as lights and camera systems. One of the laser scanners will be oriented to scan in the pan direction, the other in the tilt direction. As the lasers scan across the detector array, the angles of incidence with each detector are recorded. Combining measurements from each of the four lasers yields sufficient data for a closed-form solution of the transform describing the location and orientation of the Content Mobilization System (CMS). Redundant detectors will be placed on the CMS to accommodate occlusions, to provide improved measurement accuracy, and to determine the CMS orientation

  8. Long range position and Orientation Tracking System

    International Nuclear Information System (INIS)

    Armstrong, G.A.; Jansen, J.F.; Burks, B.L.

    1996-01-01

    The long range Position and Orientation Tracking System is an active triangulation-based system that is being developed to track a target to a resolution of 6.35 mm (0.25 in.) and 0.009 degrees(32.4 arcseconds) over a range of 13.72 m (45 ft.). The system update rate is currently set at 20 Hz but can be increased to 100 Hz or more. The tracking is accomplished by sweeping two pairs of orthogonal line lasers over infrared (IR) sensors spaced with known geometry with respect to one another on the target (the target being a rigid body attached to either a remote vehicle or a remote manipulator arm). The synchronization and data acquisition electronics correlates the time that an IR sensor has been hit by one of the four lasers and the angle of the respective mirror at the time of the hit. This information is combined with the known geometry of the IR sensors on the target to determine position and orientation of the target. This method has the advantage of allowing the target to be momentarily lost due to occlusions and then reacquired without having to return the target to a known reference point. The system also contains a camera with operator controlled lighting in each pod that allows the target to be continuously viewed from either pod, assuming their are no occlusions

  9. Fast interpolation for Global Positioning System (GPS) satellite orbits

    OpenAIRE

    Clynch, James R.; Sagovac, Christopher Patrick; Danielson, D. A. (Donald A.); Neta, Beny

    1995-01-01

    In this report, we discuss and compare several methods for polynomial interpolation of Global Positioning Systems ephemeris data. We show that the use of difference tables is more efficient than the method currently in use to construct and evaluate the Lagrange polynomials.

  10. Development of an Automatic Identification System Autonomous Positioning System

    Directory of Open Access Journals (Sweden)

    Qing Hu

    2015-11-01

    Full Text Available In order to overcome the vulnerability of the global navigation satellite system (GNSS and provide robust position, navigation and time (PNT information in marine navigation, the autonomous positioning system based on ranging-mode Automatic Identification System (AIS is presented in the paper. The principle of the AIS autonomous positioning system (AAPS is investigated, including the position algorithm, the signal measurement technique, the geometric dilution of precision, the time synchronization technique and the additional secondary factor correction technique. In order to validate the proposed AAPS, a verification system has been established in the Xinghai sea region of Dalian (China. Static and dynamic positioning experiments are performed. The original function of the AIS in the AAPS is not influenced. The experimental results show that the positioning precision of the AAPS is better than 10 m in the area with good geometric dilution of precision (GDOP by the additional secondary factor correction technology. This is the most economical solution for a land-based positioning system to complement the GNSS for the navigation safety of vessels sailing along coasts.

  11. Influence able and Avoidable Risk Factors for Systemic Air Embolism due to Percutaneous CT-Guided Lung Biopsy: Patient Positioning and Coaxial Biopsy Technique-Case Report, Systematic Literature Review, and a Technical Note

    International Nuclear Information System (INIS)

    Rott, G.; Boecker, F.

    2014-01-01

    Following the first case of a systemic air embolism due to percutaneous CT-guided lung biopsy in our clinic we analysed the literature regarding this matter in view of influence able or avoidable risk factors. A systematic review of literature reporting cases of systemic air embolism due to CT-guided lung biopsy was performed to find out whether prone positioning might be a risk factor regarding this issue. In addition, a technical note concerning coaxial biopsy practice is presented. Prone position seems to have relevance for the development and/or clinical manifestation of air embolism due to CT-guided lung biopsy and should be considered a risk factor, at least as far as lesions in the lower parts of the lung are concerned. Biopsies of small or cavitary lesions in coaxial technique should be performed using a hemo static valve.

  12. A machine protection beam position monitor system

    International Nuclear Information System (INIS)

    Medvedko, E.; Smith, S.; Fisher, A.

    1998-01-01

    Loss of the stored beam in an uncontrolled manner can cause damage to the PEP-II B Factory. We describe here a device which detects large beam position excursions or unexpected beam loss and triggers the beam abort system to extract the stored beam safely. The bad-orbit abort trigger beam position monitor (BOAT BPM) generates a trigger when the beam orbit is far off the center (>20 mm), or rapid beam current loss (dI/dT) is detected. The BOAT BPM averages the input signal over one turn (136 kHz). AM demodulation is used to convert input signals at 476 MHz to baseband voltages. The detected signal goes to a filter section for suppression of the revolution frequency, then on to amplifiers, dividers, and comparators for position and current measurements and triggering. The derived current signal goes to a special filter, designed to perform dI/dT monitoring at fast, medium, and slow current loss rates. The BOAT BPM prototype test results confirm the design concepts. copyright 1998 American Institute of Physics

  13. Ambiguity resolution for satellite Doppler positioning systems

    Science.gov (United States)

    Argentiero, P.; Marini, J.

    1979-01-01

    The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

  14. Report: Management Alert - Salary Increases for Certain Administratively Determined Positions

    Science.gov (United States)

    Report #18-N-0154, April 16, 2018. The purpose of this alert is to notify the EPA of certain factual info while our audit of the Office of the Administrator's (present and prior administrations) use of administratively determined positions continues.

  15. Environmental radiation monitoring system with GPS (global positioning system)

    International Nuclear Information System (INIS)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  16. Auto-positioning ultrasonic transducer system

    Science.gov (United States)

    Buchanan, Randy K. (Inventor)

    2010-01-01

    An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer affixed to a conduit outer surface; a guide rail attached to a receiving transducer for guiding movement of a receiving transducer along the conduit outer surface, wherein the receiving transducer receives an ultrasonic signal from the transmitting transducer and sends a signal to a data acquisition system; and a motor for moving the receiving transducer along the guide rail, wherein the motor is controlled by a controller. The method includes affixing a transmitting transducer to an outer surface of a conduit; moving a receiving transducer on the conduit outer surface, wherein the receiving transducer is moved along a guide rail by a motor; transmitting an ultrasonic signal from the transmitting transducer that is received by the receiving transducer; communicating the signal received by the receiving transducer to a data acquisition and control system; and repeating the moving, transmitting, and communicating along a length of the conduit.

  17. Global Positioning System : significant challenges in sustaining and upgrading widely used capabilities : report to the Subcommittee on National Security and Foreign Affairs, Committee on Oversight and Government Reform, House of Representatives.

    Science.gov (United States)

    2009-04-01

    The Global Positioning System (GPS), which provides positioning, navigation, and timing data to users worldwide, has become essential to U.S. national security and a key tool in an expanding array of public service and commercial applications at home...

  18. Uranium price reporting systems

    International Nuclear Information System (INIS)

    1987-09-01

    This report describes the systems for uranium price reporting currently available to the uranium industry. The report restricts itself to prices for U 3 O 8 natural uranium concentrates. Most purchases of natural uranium by utilities, and sales by producers, are conducted in this form. The bulk of uranium in electricity generation is enriched before use, and is converted to uranium hexafluoride, UF 6 , prior to enrichment. Some uranium is traded as UF 6 or as enriched uranium, particularly in the 'secondary' market. Prices for UF 6 and enriched uranium are not considered directly in this report. However, where transactions in UF 6 influence the reported price of U 3 O 8 this influence is taken into account. Unless otherwise indicated, the terms uranium and natural uranium used here refer exclusively to U 3 O 8 . (author)

  19. High accuracy autonomous navigation using the global positioning system (GPS)

    Science.gov (United States)

    Truong, Son H.; Hart, Roger C.; Shoan, Wendy C.; Wood, Terri; Long, Anne C.; Oza, Dipak H.; Lee, Taesul

    1997-01-01

    The application of global positioning system (GPS) technology to the improvement of the accuracy and economy of spacecraft navigation, is reported. High-accuracy autonomous navigation algorithms are currently being qualified in conjunction with the GPS attitude determination flyer (GADFLY) experiment for the small satellite technology initiative Lewis spacecraft. Preflight performance assessments indicated that these algorithms are able to provide a real time total position accuracy of better than 10 m and a velocity accuracy of better than 0.01 m/s, with selective availability at typical levels. It is expected that the position accuracy will be increased to 2 m if corrections are provided by the GPS wide area augmentation system.

  20. Global positioning system theory and practice

    CERN Document Server

    Hofmann-Wellenhof, Bernhard; Collins, James

    2001-01-01

    This book is dedicated to Dr. Benjamin William Remondi for many reasons. The project of writing a Global Positioning System (GPS) book was con­ ceived in April 1988 at a GPS meeting in Darmstadt, Germany. Dr. Remondi discussed with me the need for an additional GPS textbook and suggested a possible joint effort. In 1989, I was willing to commit myself to such a project. Unfortunately, the timing was less than ideal for Dr. Remondi. Therefore, I decided to start the project with other coauthors. Dr. Remondi agreed and indicated his willingness to be a reviewer. I selected Dr. Herbert Lichtenegger, my colleague from the Technical University Graz, Austria, and Dr. James Collins from Rockville, Maryland, U.S.A. In my opinion, the knowledge ofthe three authors should cover the wide spectrum of GPS. Dr. Lichtenegger is a geodesist with broad experience in both theory and practice. He has specialized his research to geodetic astron­ omy including orbital theory and geodynamical phenomena. Since 1986, Dr. Lichteneg...

  1. Connect Global Positioning System RF Module

    Science.gov (United States)

    Franklin, Garth W.; Young, Lawrence E.; Ciminera, Michael A.; Tien, Jeffrey Y.; Gorelik, Jacob; Okihiro, Brian Bachman; Koelewyn, Cynthia L.

    2012-01-01

    The CoNNeCT Global Positioning System RF Module (GPSM) slice is part of the JPL CoNNeCT Software Defined Radio (SDR). CoNNeCT is the Communications, Navigation, and Net working reconfigurable Testbed project that is part of NASA's Space Communication and Nav igation (SCaN) Program. The CoNNeCT project is an experimental dem onstration that will lead to the advancement of SDRs and provide a path for new space communication and navigation systems for future NASA exploration missions. The JPL CoNNeCT SDR will be flying on the International Space Station (ISS) in 2012 in support of the SCaN CoNNeCT program. The GPSM is a radio-frequency sampler module (see Figure 1) that directly sub-harmonically samples the filtered GPS L-band signals at L1 (1575.42 MHz), L2 (1227.6 MHz), and L5 (1176.45 MHz). The JPL SDR receives GPS signals through a Dorne & Margolin antenna mounted onto a choke ring. The GPS signal is filtered against interference, amplified, split, and fed into three channels: L1, L2, and L5. In each of the L-band channels, there is a chain of bandpass filters and amplifiers, and the signal is fed through each of these channels to where the GPSM performs a one-bit analog-to-digital conversion (see Figure 2). The GPSM uses a sub-harmonic, single-bit L1, L2, and L5 sampler that samples at a clock rate of 38.656 MHz. The new capability is the down-conversion and sampling of the L5 signal when previous hardware did not provide this capability. The first GPS IIF Satellite was launched in 2010, providing the new L5 signal. With the JPL SDR flying on the ISS, it will be possible to demonstrate navigation solutions with 10-meter 3-D accuracy at 10-second intervals using a field-program mable gate array (FPGA)-based feedback loop running at 50 Hz. The GPS data bits will be decoded and used in the SDR. The GPSM will also allow other waveforms that are installed in the SDR to demonstrate various GNSS tracking techniques.

  2. Evaluation of a continuous-positive pressure generating system

    Directory of Open Access Journals (Sweden)

    Herrera N

    2016-03-01

    Full Text Available Nestor Herrera,1,2 Roberto Regnícoli,1,2 Mariel Murad1,2 1Neonatology Unit, Italian Hospital Garibaldi, Rosario, Argentina; 2Experimental Medicine and Surgery Unit, Italian University Institute of Rosario, Argentina Abstract: The use of systems that apply continuous-positive airway pressure by means of noninvasive methods is widespread in the neonatal care practice and has been associated with a decrease in the use of invasive mechanical ventilation, less administration of exogenous surfactant, and bronchopulmonary dysplasia. Few experimental studies on the functioning of the neonatology systems that generate continuous-positive airway pressure have been reported. A flow resistor system associated with an underwater seal resistor in a lung test model was described, and it was compared with an underwater seal threshold resistor system. Important differences in the pressures generated in the different systems studied were verified. The generation of pressure was associated with the immersion depth and the diameter of the bubble tubing. The flow resistor associated with an underwater seal, with small bubble tubing, showed no important differences in the evaluated pressures, exerting a stabilizing effect on the generated pressures. The importance of measuring the pressure generated by the different systems studied was verified, due to the differences between the working pressures set and the pressures measured. Keywords: continuous-positive pressure, flow and threshold resistor, BCPAP

  3. Ovarian pregnancy in an HIV positive patient: Case report ...

    African Journals Online (AJOL)

    Ovarian pregnancy in an HIV positive patient: Case report. A Mohammed, AG Adesiyun, AA Mayun, CA Ameh. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  4. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  5. System and method for acquisition management of subject position information

    Science.gov (United States)

    Carrender, Curt

    2005-12-13

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  6. System and method for acquisition management of subject position information

    Energy Technology Data Exchange (ETDEWEB)

    Carrender, Curt [Morgan Hill, CA

    2007-01-23

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  7. Downsizing of health-system pharmacist positions.

    Science.gov (United States)

    Kahaleh, A A; Siganga, W; Holiday-Goodman, M; Lively, B T

    1998-11-15

    The effects of downsizing on institutional pharmacists were studied. A national mail survey was sent to a random sample of 533 members of ASHP in January 1997. The questionnaire was designed to determine (1) the influence of selected factors on the downsizing of pharmacist positions and (2) pharmacists' attitudes about downsizing. A total of 256 usable questionnaires were received, for a net response rate of 48%. Forty-four pharmacists, or 17%, had personally been affected by downsizing. Sixty-one percent of the pharmacists affected by downsizing had had administrative positions. After downsizing, only 32% of the pharmacists had an administrative position. Most of the pharmacists were currently employed. Thirty-five (79%) described their current job responsibilities as substantially changed. Two thirds made the same salaries or higher salaries. Pharmacists who had been downsized rated mergers, the impact of managed care, and the profit motive as the most influential causes of downsizing of pharmacist positions. The three most common negative comments about the impact of downsizing cited reduction in the quality of patient care, increased stress, and lowered morale. Most of the pharmacists believed that communication skills, education, cross-training, and clinical skills are keys to surviving downsizing. Most pharmacists whose positions were downsized said they went on to jobs with similar or higher salaries and substantially different responsibilities.

  8. Accurate radiotherapy positioning system investigation based on video

    International Nuclear Information System (INIS)

    Tao Shengxiang; Wu Yican

    2006-01-01

    This paper introduces the newest research production on patient positioning method in accurate radiotherapy brought by Accurate Radiotherapy Treating System (ARTS) research team of Institute of Plasma Physics of Chinese Academy of Sciences, such as the positioning system based on binocular vision, the position-measuring system based on contour matching and the breath gate controlling system for positioning. Their basic principle, the application occasion and the prospects are briefly depicted. (authors)

  9. Integrated system checkout report

    International Nuclear Information System (INIS)

    1991-01-01

    The planning and preparation phase of the Integrated Systems Checkout Program (ISCP) was conducted from October 1989 to July 1991. A copy of the ISCP, DOE-WIPP 90--002, is included in this report as an appendix. The final phase of the Checkout was conducted from July 10, 1991, to July 23, 1991. This phase exercised all the procedures and equipment required to receive, emplace, and retrieve contact handled transuranium (CH TRU) waste filled dry bins. In addition, abnormal events were introduced to simulate various equipment failures, loose surface radioactive contamination events, and personnel injury. This report provides a detailed summary of each days activities during this period. Qualification of personnel to safely conduct the tasks identified in the procedures and the abnormal events were verified by observers familiar with the Bin-Scale CH TRU Waste Test requirements. These observers were members of the staffs of Westinghouse WID Engineering, QA, Training, Health Physics, Safety, and SNL. Observers representing a number of DOE departments, the state of new Mexico, and the Defense Nuclear Facilities Safety Board observed those Checkout activities conducted during the period from July 17, 1991, to July 23, 1991. Observer comments described in this report are those obtained from the staff member observers. 1 figs., 1 tab

  10. True self-alienation positively predicts reports of mindwandering.

    Science.gov (United States)

    Vess, Matthew; Leal, Stephanie A; Hoeldtke, Russell T; Schlegel, Rebecca J; Hicks, Joshua A

    2016-10-01

    Two studies assessed the relationship between feelings of uncertainty about who one truly is (i.e., true self-alienation) and self-reported task-unrelated thoughts (i.e., mindwandering) during performance tasks. Because true self-alienation is conceptualized as the subjective disconnect between conscious awareness and actual experience, we hypothesized that greater feelings of true self-alienation would positively relate to subjective reports of mindwandering. Two convergent studies supported this hypothesis. Moreover, this relationship could not consistently be accounted for by the independent influence of other aspects of authenticity, negative mood, mindfulness, or broad personality dimensions. These findings suggest that individual differences in true self-alienation are reliably associated with subjective reports of mindwandering. The implications of these findings for the true self-alienation construct, the ways that personality relates to mindwandering, and future research directions focused on curtailing mindwandering and improving performance and achievement are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. LGBTQ relationally based positive psychology: An inclusive and systemic framework.

    Science.gov (United States)

    Domínguez, Daniela G; Bobele, Monte; Coppock, Jacqueline; Peña, Ezequiel

    2015-05-01

    Positive psychologists have contributed to our understandings of how positive emotions and flexible cognition enhance resiliency. However, positive psychologists' research has been slow to address the relational resources and interactions that help nonheterosexual families overcome adversity. Addressing overlooked lesbian, gay, bisexual, transgender, or queer (LGBTQ) and systemic factors in positive psychology, this article draws on family resilience literature and LGBTQ literature to theorize a systemic positive psychology framework for working with nonheterosexual families. We developed the LGBTQ relationally based positive psychology framework that integrates positive psychology's strengths-based perspective with the systemic orientation of Walsh's (1996) family resilience framework along with the cultural considerations proposed by LGBTQ family literature. We theorize that the LGBTQ relationally based positive psychology framework takes into consideration the sociopolitical adversities impacting nonheterosexual families and sensitizes positive psychologists, including those working in organized care settings, to the systemic interactions of same-sex loving relationships. (c) 2015 APA, all rights reserved).

  12. Current Status of the Beam Position Monitoring System at TLS

    Science.gov (United States)

    Kuo, C. H.; Hu, K. H.; Chen, Jenny; Lee, Demi; Wang, C. J.; Hsu, S. Y.; Hsu, K. T.

    2006-11-01

    The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This report summarizes the system structure, the software environment and the preliminary beam test of the BPM system.

  13. Two-dimensional approach to relativistic positioning systems

    International Nuclear Information System (INIS)

    Coll, Bartolome; Ferrando, Joan Josep; Morales, Juan Antonio

    2006-01-01

    A relativistic positioning system is a physical realization of a coordinate system consisting in four clocks in arbitrary motion broadcasting their proper times. The basic elements of the relativistic positioning systems are presented in the two-dimensional case. This simplified approach allows to explain and to analyze the properties and interest of these new systems. The positioning system defined by geodesic emitters in flat metric is developed in detail. The information that the data generated by a relativistic positioning system give on the space-time metric interval is analyzed, and the interest of these results in gravimetry is pointed out

  14. ESRF synchrotron injector beam position monitor system

    International Nuclear Information System (INIS)

    Scheidt, K.; Loyer, F.

    1992-01-01

    The complete lay-out of the BPM system which comprises 75 individual stations is presented from electro-static button signals down to the user level of the computer interface. The design of the electrode button and the block geometry is presented. The timing and the data-acquisition electronics permit precisely timed measurements to be taken simultaneously on all 75 BPM stations at a rate of 1 KHz. The results of this BPM system, are summarised with the performance characteristics of resolution, precision and reproductibility. (author) 4 refs.; 4 figs

  15. Positive dynamical systems in discrete time theory, models, and applications

    CERN Document Server

    Krause, Ulrich

    2015-01-01

    This book provides a systematic, rigorous and self-contained treatment of positive dynamical systems. A dynamical system is positive when all relevant variables of a systemare nonnegative in a natural way. This is in biology, demography or economics, where the levels of populations or prices of goods are positive. The principle also finds application in electrical engineering, physics and computer sciences.

  16. Live birth pregnancy outcome after first in vitro fertilization treatment in a patient with Systemic Lupus Erythematosus and isolated high positive IgA anti-β2glycoprotein I antibodies: a case report

    Directory of Open Access Journals (Sweden)

    Andreeva Hristina

    2017-03-01

    Full Text Available IgA anti-β2glycoprotein I antibodies (IgA-anti-β2GPI seems to be the most prevalent isotype in patients with Systemic Lupus Erythematosus (SLE with a significant association to thrombotic events. Both SLE and antiphospholipid syndrome (APS can be associated with implantation failure, fetal loss and obstetric complications. Recent reports highlight the clinical value of IgA-anti-β2GPI determination in supporting in vitro fertilization (IVF treatment and IVF pregnancy outcomes. We report a 36-year-old female diagnosed with SLE, endometriosis and unexplained infertility. Conventional APS markers were consistently negative: anti-cardiolipin (aCL and anti-β2GPI: IgG/IgM. She was then tested with reports of repeatedly high IgA-anti-β2GPI and tested positive from 2014 after IgA (aCL; anti-β2GPI were established in our APS diagnostic panel. She underwent successful first IVF procedure with a 30 week live birth pregnancy outcome. During the follow up no lupus flare, thrombosis or ovarian hyperstimulation syndrome were registered. Serum IgA anti-β2GPI and anti-dsDNA levels declined statistically significant during the second and third trimester. Titres of IgA-anti-β2GPI remained lower postpartum as well. This case highlights the clinical importance of IgA-anti-β2GPI testing for family planning, assisted reproduction and pregnancy in women with SLE and/or APS.

  17. Free positioning for inductive wireless power system

    NARCIS (Netherlands)

    Waffenschmidt, E.

    2012-01-01

    In inductive wireless power transmission system a lateral displacement of the receiver coil to the transmitter coil leads to a change ofthe coupling factor and thus an unwanted variation of the power transfer. Here, an algorithm to determine the turn distribution to achieve homogeneous coupling

  18. Fuels Reporting System Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes compliance data (registrations and reports), including reports related to reformulated gasoline and conventional gasoline (anti-dumping),...

  19. A New Indoor Positioning System Architecture Using GPS Signals.

    Science.gov (United States)

    Xu, Rui; Chen, Wu; Xu, Ying; Ji, Shengyue

    2015-04-29

    The pseudolite system is a good alternative for indoor positioning systems due to its large coverage area and accurate positioning solution. However, for common Global Positioning System (GPS) receivers, the pseudolite system requires some modifications of the user terminals. To solve the problem, this paper proposes a new pseudolite-based indoor positioning system architecture. The main idea is to receive real-world GPS signals, repeat each satellite signal and transmit those using indoor transmitting antennas. The transmitted GPS-like signal can be processed (signal acquisition and tracking, navigation data decoding) by the general receiver and thus no hardware-level modification on the receiver is required. In addition, all Tx can be synchronized with each other since one single clock is used in Rx/Tx. The proposed system is simulated using a software GPS receiver. The simulation results show the indoor positioning system is able to provide high accurate horizontal positioning in both static and dynamic situations.

  20. A positioning and data logging system for surface geophysical surveys

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Blair, M.S.

    1988-01-01

    The Ultrasonic Ranging and Data System (USRADS) developed at ORNL is being adapted to work with two commercially available geophysical instruments: a magnetometer and an EM31 terrain conductivity meter. Geophysical surveys have proven an important preliminary step in investigating hazardous waste sites. Magnetometers and terrain conductivity meters are used to locate buried drums, trenches, conductive contaminant plumes and map regional changes in geology. About half the field time of a typical geophysical investigation is spent surveying the position of the grid points at which the measurements will be made. Additional time is lost and errors may be made recording instrument values in field notebooks and transcribing the data to a computer. Developed for gamma radiation surveys, the USRAD system keeps track of the surveyor's position automatically by triangulating on an ultrasonic transmitter carried in a backpack. The backpack also contains a radio transmitter that sends the instrument's reading coincident with the ultrasonic pulse. The surveyor's position and the instrument's reading are recorded by a portable computer which can plot the data to check the survey's progress. Electronic files are stored in a form compatible with AutoCAD to speed report writing. 7 refs., 3 figs

  1. A description of QUALCOMM Automatic Satellite Position Reporting (QASPR(R)) for mobile communications

    Science.gov (United States)

    Ames, William G.

    1990-01-01

    Two satellite position reporting has been introduced into the OmniTRACS mobile satellite communication system. This system significantly improves position reporting reliability and accuracy while simplifying the terminal's hardware. The positioning technique uses the original OmniTRACS TDMA timing signal formats in the forward and return link directions plus an auxiliary, low power forward link signal through a second satellite to derive distance values. The distances are then converted into the mobile terminal's latitude and longitude in real time. A minor augmentation of the spread spectrum profile of the return link allowed the resolution of periodic ambiguities. The system also locates the two satellites in real time with fixed platforms in known locations using identical mobile terminal hardware. Initial accuracies of 1/4 mile have been realized uniformly throughout the USA using a satellite separation of 22 degrees and there are no dead zones, skywaves, or cycle slips as found in terrestrial systems like LORAN-C.

  2. Physician Quality Reporting System

    Data.gov (United States)

    U.S. Department of Health & Human Services — PQRS is a reporting program that uses a combination of incentive payments and negative payment adjustments to promote reporting of quality information by eligible...

  3. The aviation safety reporting system

    Science.gov (United States)

    Reynard, W. D.

    1984-01-01

    The aviation safety reporting system, an accident reporting system, is presented. The system identifies deficiencies and discrepancies and the data it provides are used for long term identification of problems. Data for planning and policy making are provided. The system offers training in safety education to pilots. Data and information are drawn from the available data bases.

  4. Error Analysis of Determining Airplane Location by Global Positioning System

    OpenAIRE

    Hajiyev, Chingiz; Burat, Alper

    1999-01-01

    This paper studies the error analysis of determining airplane location by global positioning system (GPS) using statistical testing method. The Newton Rhapson method positions the airplane at the intersection point of four spheres. Absolute errors, relative errors and standard deviation have been calculated The results show that the positioning error of the airplane varies with the coordinates of GPS satellite and the airplane.

  5. Impact of emotion on consciousness: positive stimuli enhance conscious reportability.

    Directory of Open Access Journals (Sweden)

    Kristine Rømer Thomsen

    2011-04-01

    Full Text Available Emotion and reward have been proposed to be closely linked to conscious experience, but empirical data are lacking. The anterior cingulate cortex (ACC plays a central role in the hedonic dimension of conscious experience; thus potentially a key region in interactions between emotion and consciousness. Here we tested the impact of emotion on conscious experience, and directly investigated the role of the ACC. We used a masked paradigm that measures conscious reportability in terms of subjective confidence and objective accuracy in identifying the briefly presented stimulus in a forced-choice test. By manipulating the emotional valence (positive, neutral, negative and the presentation time (16 ms, 32 ms, 80 ms we measured the impact of these variables on conscious and subliminal (i.e. below threshold processing. First, we tested normal participants using face and word stimuli. Results showed that participants were more confident and accurate when consciously seeing happy versus sad/neutral faces and words. When stimuli were presented subliminally, we found no effect of emotion. To investigate the neural basis of this impact of emotion, we recorded local field potentials (LFPs directly in the ACC in a chronic pain patient. Behavioural findings were replicated: the patient was more confident and accurate when (consciously seeing happy versus sad faces, while no effect was seen in subliminal trials. Mirroring behavioural findings, we found significant differences in the LFPs after around 500 ms (lasting 30 ms in conscious trials between happy and sad faces, while no effect was found in subliminal trials. We thus demonstrate a striking impact of emotion on conscious experience, with positive emotional stimuli enhancing conscious reportability. In line with previous studies, the data indicate a key role of the ACC, but goes beyond earlier work by providing the first direct evidence of interaction between emotion and conscious experience in the human

  6. An intelligent operator support system for dynamic positioning

    NARCIS (Netherlands)

    Diggelen, J. van; Broek, J. van den; Schraagen, J.M.C.; Waa, J.S. van der

    2018-01-01

    This paper proposes a human-centered approach to Dynamic Position-ing systems which combines multiple technologies in an intelligent operator sup-port system (IOSS). IOSS allows the operator to be roaming and do other tasks in quiet conditions. When conditions become more demanding, the IOSS calls

  7. Revised licensee event report system

    International Nuclear Information System (INIS)

    Mays, G.T.; Poore, W.P.

    1985-01-01

    Licensee Event Reports (LERs) provide the basis for evaluating and assessing operating experience information from nuclear power plants. The reporting requirements for submitting LERs to the Nuclear Regulatory Commission have been revised. Effective Jan. 1, 1984, all events were to be submitted in accordance with 10 CFR 50.73 of the Code of Federal Regulations. Report NUREG-1022, Licensee Event Report System-Description of System and Guidelines for Reporting, describes the guidelines on reportability of events. This article summarizes the reporting requirements as presented in NUREG-1022, high-lights differences in data reported between the revised and previous LER systems, and presents results from a preliminary assessment of LERs submitted under the revised LER reporting system

  8. 78 FR 51078 - Reporting Requirements for Positive Train Control Expenses and Investments

    Science.gov (United States)

    2013-08-20

    ...] Reporting Requirements for Positive Train Control Expenses and Investments AGENCY: Surface Transportation... investments and expenses. PTC is an automated system designed to prevent train-to-train collisions and other..., PTC expenditures are incorporated into the R-1 under the category of ``capital investments and...

  9. Designing compensator of dual servo system for high precision positioning

    International Nuclear Information System (INIS)

    Choi, Hyeun Seok; Song, Chi Woo; Han, Chang Soo; Choi, Tae Hoon; Lee, Nak Kyu; Na, Kyung Hwan

    2003-01-01

    The high precision positioning mechanism is used in various industrial fields. It is used in semiconductor manufacturing line, test instrument, bioengineering, and MEMS and so on. This paper presents a positioning mechanism with dual servo system. Dual servo system consists of a coarse stage and a fine motion stage. The course stage is driven by VCM and the actuator of fine stage is the PZT. The purposes of dual servo system are stability, higher bandwidth, and robustness. Lead compensator is applied to this control system, and is designed by PQ method. Designed compensator can improve property of positioning mechanism

  10. Congestion Management System Process Report

    Science.gov (United States)

    1996-03-01

    In January 1995, the Indianapolis Metropolitan Planning Organization with the help of an interagency Study Review Committee began the process of developing a Congestion Management System (CMS) Plan resulting in this report. This report documents the ...

  11. Robust Position Control of Electro-mechanical Systems

    OpenAIRE

    Rong Mei; Mou Chen

    2013-01-01

    In this work, the robust position control scheme is proposed for the electro-mechanical system using the disturbance observer and backstepping control method. To the external unknown load of the electro-mechanical system, the nonlinear disturbance observer is given to estimate the external unknown load. Combining the output of the developed nonlinear disturbance observer with backstepping technology, the robust position control scheme is proposed for the electro-mechanical system. The stabili...

  12. Real-time precision pedestrian navigation solution using Inertial Navigation System and Global Positioning System

    OpenAIRE

    Yong-Jin Yoon; King Ho Holden Li; Jiahe Steven Lee; Woo-Tae Park

    2015-01-01

    Global Positioning System and Inertial Navigation System can be used to determine position and velocity. A Global Positioning System module is able to accurately determine position without sensor drift, but its usage is limited in heavily urbanized environments and heavy vegetation. While high-cost tactical-grade Inertial Navigation System can determine position accurately, low-cost micro-electro-mechanical system Inertial Navigation System sensors are plagued by significant errors. Global Po...

  13. Context Aware Handover Algorithms For Mobile Positioning Systems

    Directory of Open Access Journals (Sweden)

    Sazid Z. Khan

    2014-01-01

    Full Text Available Abstract: This work proposes context aware handover algorithms for mobile positioning systems. The algorithms perform handover among positioning systems based on important contextual factors related to position determination with efficient use of battery. The proposed solution which consists of the algorithms is implemented in the form of an Android application named Locate@nav6. The performance of the proposed solution was tested in selected experimental areas. The handover performance was compared with other existing location applications. The proposed solution performed correct handover among positioning systems in 95% of cases studied while two other applications performed correct handover in only 50% of cases studied. Battery usage of the proposed solution is less than one third of the battery usage of two other applications. The analysis of the positioning error of the applications demonstrated that, the proposed solution is able to reduce positioning error indirectly by handing over the task of positioning to an appropriate positioning system. This kept the average error of positioning below 42.1 meters for Locate@nav6 while the average error for two other applications namely Google Latitude and Malaysia maps was between 92.7 and 171.13 meters.

  14. Modelling and control of neutron and synchrotron beamline positioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nneji, S.O., E-mail: Stephen.nneji@open.ac.uk [The Open University, Materials Engineering, Walton Hall, Milton Keynes, Buckinghamshire MK7 6AA (United Kingdom); Science and Technology Facility Council , Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX110QX Oxfordshire (United Kingdom); Zhang, S.Y.; Kabra, S. [Science and Technology Facility Council , Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX110QX Oxfordshire (United Kingdom); Moat, R.J.; James, J.A. [The Open University, Materials Engineering, Walton Hall, Milton Keynes, Buckinghamshire MK7 6AA (United Kingdom)

    2016-03-21

    Measurement of residual stress using neutron or synchrotron diffraction relies on the accurate alignment of the sample in relation to the gauge volume of the instrument. Automatic sample alignment can be achieved using kinematic models of the positioning system provided the relevant kinematic parameters are known, or can be determined, to a suitable accuracy. In this paper, the use of techniques from robotic calibration theory to generate kinematic models of both off-the-shelf and custom-built positioning systems is demonstrated. The approach is illustrated using a positioning system in use on the ENGIN-X instrument at the UK's ISIS pulsed neutron source comprising a traditional XYZΩ table augmented with a triple axis manipulator. Accuracies better than 100 microns were achieved for this compound system. Discussed here in terms of sample positioning systems these methods are entirely applicable to other moving instrument components such as beam shaping jaws and detectors.

  15. Contractor Performance Assessment Reporting System

    Data.gov (United States)

    US Agency for International Development — CPARS is a web-based system used to input data on contractor performance. Reports from the system are used as an aid in awarding contracts to contractors that...

  16. Modeling and Positioning of a PZT Precision Drive System

    Directory of Open Access Journals (Sweden)

    Che Liu

    2017-11-01

    Full Text Available The fact that piezoelectric ceramic transducer (PZT precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.

  17. Modeling and Positioning of a PZT Precision Drive System.

    Science.gov (United States)

    Liu, Che; Guo, Yanling

    2017-11-08

    The fact that piezoelectric ceramic transducer (PZT) precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD) is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK) was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.

  18. Beam Position and Phase Monitor - Wire Mapping System

    International Nuclear Information System (INIS)

    Watkins, Heath A.; Shurter, Robert B.; Gilpatrick, John D.; Kutac, Vincent G.; Martinez, Derwin

    2012-01-01

    The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

  19. A radio vehicle position reporting technique that is protected from interception and directional fixes

    International Nuclear Information System (INIS)

    Kraft, C.

    1987-01-01

    Vehicles used to transport nuclear materials can determine their position with respect to an established grid by electronic means such as geosynchronous navigation satellite (GPS) or hyperbolic radio. It is frequently necessary to relay this position information via a radio link to a command center. This gives a potential adversary two means of determining the vehicle's location: first, by simply intercepting and reading out the transmitted position data, second, by making a radio directional fix on the mobile transmitter. If a modern data encryption technique is used, the usefulness of interception almost disappears. The DF threat can be countered by using a system that transmit at low power for very short intervals over a wide bandwidth. This is because the probability of a successful DF fix is related to the ability to lock a phase-locked loop in noise, and each of the above factors works against such locking. A robust system can be designed at reasonable cost to accomplish successful position data reporting with a very low probability of successful DF by an adversary because the DF problems is much more difficult technically then the data transmission problem, and a position reporting system does not need to spend much time actually transmitting. A hypothetical system is presented that is called burst mode frequency hopping (BMFH). The mobile transmitter sends very short modulated bursts that are hopped through a pseudo-random frequency map. Actual data are encrypted and then embedded in an interleaved error correcting code

  20. Point processes and the position distribution of infinite boson systems

    International Nuclear Information System (INIS)

    Fichtner, K.H.; Freudenberg, W.

    1987-01-01

    It is shown that to each locally normal state of a boson system one can associate a point process that can be interpreted as the position distribution of the state. The point process contains all information one can get by position measurements and is determined by the latter. On the other hand, to each so-called Σ/sup c/-point process Q they relate a locally normal state with position distribution Q

  1. A Survey of Indoor Positioning Systems for Wireless Personal Networks

    NARCIS (Netherlands)

    Gu, Y.; Lo, A.; Niemegeers, I.

    2009-01-01

    Recently, indoor positioning systems (IPSs) have been designed to provide location information of persons and devices. The position information enables location-based protocols for user applications. Personal networks (PNs) are designed to meet the users' needs and interconnect users' devices

  2. The Ether Wind and the Global Positioning System.

    Science.gov (United States)

    Muller, Rainer

    2000-01-01

    Explains how students can perform a refutation of the ether theory using information from the Global Positioning System (GPS). Discusses the functioning of the GPS, qualitatively describes how position determination would be affected by an ether wind, and illustrates the pertinent ideas with a simple quantitative model. (WRM)

  3. 78 FR 22554 - Nationwide Differential Global Positioning System (NDGPS)

    Science.gov (United States)

    2013-04-16

    ... accuracy and integrity of the Global Positioning System (GPS) derived positions for surface transportation..., contact LT Luke Byrd, Coast Guard, NDGPS Program Manager, telephone 202-372-1547 or email Robert.l.byrd... The NDGPS augments GPS with an additional differential correction signal. Differential GPS (DGPS...

  4. Communication-based positioning systems: past, present and prospects

    International Nuclear Information System (INIS)

    Ma Guanyi; Wan Qingtao; Gan Tong

    2012-01-01

    This paper reviews positioning systems in the context of communication systems. First, the basic positioning technique is described for location based service (LBS) in mobile communication systems. Then the high integrity global positioning system (iGPS) is introduced in terms of aspects of what it is and how the low Earth orbit (LEO) Iridium telecommunication satellites enhance the global positioning system (GPS). Emphasis is on the Chinese Area Positioning System (CAPS) which is mainly based on commercial geostationary (GEO) communication satellites, including decommissioned GEO and inclined geosynchronous communication satellites. Characterized by its low cost, high flexibility, wide-area coverage and ample frequency resources, a distinctive feature of CAPS is that its navigation messages are generated on the ground, then uploaded to and forwarded by the communication satellites. Fundamental principles and key technologies applied in the construction of CAPS are presented in detail from the CAPS validation phase to its experimental system setup. A prospective view of CAPS has concluded it to be a seamless, high accuracy, large capacity navigation and communication system which can be achieved by expanding it world wide and enhancing it with LEO satellites and mobile base stations. Hence, this system is a potential candidate for the next generation of radio navigation after GPS. (invited reviews)

  5. High precision relative position sensing system for formation flying spacecraft

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop and test an optical sensing system that provides high precision relative position sensing for formation flying spacecraft.  A high precision...

  6. total electron content derived from global positioning system during ...

    African Journals Online (AJOL)

    SULUNGU

    POSITIONING SYSTEM DURING SOLAR MAXIMUM OF 2012-2013. OVER THE ..... diffusion of the transported electrons from the equator (Panda et al. 2015). As the sun rises, the ..... Wang M and Christensen AB 2008 Features of annual and ...

  7. Coordinated joint motion control system with position error correction

    Science.gov (United States)

    Danko, George L.

    2016-04-05

    Disclosed are an articulated hydraulic machine supporting, control system and control method for same. The articulated hydraulic machine has an end effector for performing useful work. The control system is capable of controlling the end effector for automated movement along a preselected trajectory. The control system has a position error correction system to correct discrepancies between an actual end effector trajectory and a desired end effector trajectory. The correction system can employ one or more absolute position signals provided by one or more acceleration sensors supported by one or more movable machine elements. Good trajectory positioning and repeatability can be obtained. A two joystick controller system is enabled, which can in some cases facilitate the operator's task and enhance their work quality and productivity.

  8. 1 nA beam position monitoring system

    International Nuclear Information System (INIS)

    Ursic, R.; Flood, R.; Piller, C.

    1997-01-01

    A system has been developed at Jefferson Lab for measuring transverse position of very low current beams delivered to the Experimental Hall B of the Continuous Electron Beam Accelerator Facility (CEBAF). At the heart of the system is a position sensitive cavity operating at 1497 MHz. The cavity utilizes a unique design which achieves a high sensitivity to beam position at a relatively low cavity Q. The cavity output RF signal is processed using a down-converter and a commercial lock-in amplifier operating at 100 kHz. The system interfaces with a VME based EPICS control system using the IEEE, 488 bus. The main features of the system are simple and robust design, and wide dynamic range capable of handling beam currents from 1 nA to 1000 nA with an expected resolution better than 100 μm. This paper outlines the design of the system

  9. A new UHV micro positioning system for high load

    Energy Technology Data Exchange (ETDEWEB)

    Colldelram, Carles, E-mail: ccolldelram@cells.es; Nicolas, Josep, E-mail: jnicolas@cells.es; Nikitina, Liudmila, E-mail: lnikitina@cells.es [ALBA Synchrotron, Carretera BP 1413, de Cerdanyola del Vallès a Sant Cugat del Vallès, Km. 3,3, 08290 Cerdanyola del Vallès, Barcelona (Spain)

    2016-07-27

    have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.

  10. A new UHV micro positioning system for high load

    International Nuclear Information System (INIS)

    Colldelram, Carles; Nicolas, Josep; Nikitina, Liudmila

    2016-01-01

    have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.

  11. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    International Nuclear Information System (INIS)

    Branch, C.J.; Kearfott, K.J.

    1999-01-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design

  12. Advanced Pedestrian Positioning System to Smartphones and Smartwatches

    Directory of Open Access Journals (Sweden)

    Alejandro Correa

    2016-11-01

    Full Text Available In recent years, there has been an increasing interest in the development of pedestrian navigation systems for satellite-denied scenarios. The popularization of smartphones and smartwatches is an interesting opportunity for reducing the infrastructure cost of the positioning systems. Nowadays, smartphones include inertial sensors that can be used in pedestrian dead-reckoning (PDR algorithms for the estimation of the user’s position. Both smartphones and smartwatches include WiFi capabilities allowing the computation of the received signal strength (RSS. We develop a new method for the combination of RSS measurements from two different receivers using a Gaussian mixture model. We also analyze the implication of using a WiFi network designed for communication purposes in an indoor positioning system when the designer cannot control the network configuration. In this work, we design a hybrid positioning system that combines inertial measurements, from low-cost inertial sensors embedded in a smartphone, with RSS measurements through an extended Kalman filter. The system has been validated in a real scenario, and results show that our system improves the positioning accuracy of the PDR system thanks to the use of two WiFi receivers. The designed system obtains an accuracy up to 1.4 m in a scenario of 6000 m 2 .

  13. Indoor Positioning System Using Depth Maps and Wireless Networks

    Directory of Open Access Journals (Sweden)

    Jaime Duque Domingo

    2016-01-01

    Full Text Available This work presents a new Indoor Positioning System (IPS based on the combination of WiFi Positioning System (WPS and depth maps, for estimating the location of people. The combination of both technologies improves the efficiency of existing methods, based uniquely on wireless positioning techniques. While other positioning systems force users to wear special devices, the system proposed in this paper just requires the use of smartphones, besides the installation of RGB-D sensors in the sensing area. Furthermore, the system is not intrusive, being not necessary to know people’s identity. The paper exposes the method developed for putting together and exploiting both types of sensory information with positioning purposes: the measurements of the level of the signal received from different access points (APs of the wireless network and the depth maps provided by the RGB-D cameras. The obtained results show a significant improvement in terms of positioning with respect to common WiFi-based systems.

  14. Digitized video subject positioning and surveillance system for PET

    International Nuclear Information System (INIS)

    Picard, Y.; Thompson, C.J.

    1995-01-01

    Head motion is a significant contribution to the degradation of image quality of Positron Emission Tomography (PET) studies. Images from different studies must also be realigned digitally to be correlated when the subject position has changed. These constraints could be eliminated if the subject's head position could be monitored accurately. The authors have developed a video camera-based surveillance system to monitor the head position and motion of subjects undergoing PET studies. The system consists of two CCD (charge-coupled device) cameras placed orthogonally such that both face and profile views of the subject's head are displayed side by side on an RGB video monitor. Digitized images overlay the live images in contrasting colors on the monitor. Such a system can be used to (1) position the subject in the field of view (FOV) by displaying the position of the scanner's slices on the monitor along with the current subject position, (2) monitor head motion and alert the operator of any motion during the study and (3) reposition the subject accurately for subsequent studies by displaying the previous position along with the current position in a contrasting color

  15. Distributed magnetic field positioning system using code division multiple access

    Science.gov (United States)

    Prigge, Eric A. (Inventor)

    2003-01-01

    An apparatus and methods for a magnetic field positioning system use a fundamentally different, and advantageous, signal structure and multiple access method, known as Code Division Multiple Access (CDMA). This signal architecture, when combined with processing methods, leads to advantages over the existing technologies, especially when applied to a system with a large number of magnetic field generators (beacons). Beacons at known positions generate coded magnetic fields, and a magnetic sensor measures a sum field and decomposes it into component fields to determine the sensor position and orientation. The apparatus and methods can have a large `building-sized` coverage area. The system allows for numerous beacons to be distributed throughout an area at a number of different locations. A method to estimate position and attitude, with no prior knowledge, uses dipole fields produced by these beacons in different locations.

  16. Automatic multi-camera calibration for deployable positioning systems

    Science.gov (United States)

    Axelsson, Maria; Karlsson, Mikael; Rudner, Staffan

    2012-06-01

    Surveillance with automated positioning and tracking of subjects and vehicles in 3D is desired in many defence and security applications. Camera systems with stereo or multiple cameras are often used for 3D positioning. In such systems, accurate camera calibration is needed to obtain a reliable 3D position estimate. There is also a need for automated camera calibration to facilitate fast deployment of semi-mobile multi-camera 3D positioning systems. In this paper we investigate a method for automatic calibration of the extrinsic camera parameters (relative camera pose and orientation) of a multi-camera positioning system. It is based on estimation of the essential matrix between each camera pair using the 5-point method for intrinsically calibrated cameras. The method is compared to a manual calibration method using real HD video data from a field trial with a multicamera positioning system. The method is also evaluated on simulated data from a stereo camera model. The results show that the reprojection error of the automated camera calibration method is close to or smaller than the error for the manual calibration method and that the automated calibration method can replace the manual calibration.

  17. Water Fluoridation Reporting System (Public Water Systems)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Water Fluoridation Reporting System (WFRS) has been developed to provide tools to assist states in managing fluoridation programs. WFRS is designed to track all...

  18. The realization problem for positive and fractional systems

    CERN Document Server

    Kaczorek, Tadeusz

    2014-01-01

    This book addresses the realization problem of positive and fractional continuous-time and discrete-time linear systems. Roughly speaking the essence of the realization problem can be stated as follows: Find the matrices of the state space equations of linear systems for given their transfer matrices. This first book on this topic shows how many well-known classical approaches have been extended to the new classes of positive and fractional linear systems. The modified Gilbert method for multi-input multi-output linear systems, the method for determination of realizations in the controller canonical forms and in observer canonical forms are presented. The realization problem for linear systems described by differential operators, the realization problem in the Weierstrass canonical forms and of the descriptor linear systems for given Markov parameters are addressed. The book also presents a method for the determination of minimal realizations of descriptor linear systems and an extension for cone linear syste...

  19. Adults with an epilepsy history fare significantly worse on positive mental and physical health than adults with other common chronic conditions-Estimates from the 2010 National Health Interview Survey and Patient Reported Outcome Measurement System (PROMIS) Global Health Scale.

    Science.gov (United States)

    Kobau, Rosemarie; Cui, Wanjun; Zack, Matthew M

    2017-07-01

    Healthy People 2020, a national health promotion initiative, calls for increasing the proportion of U.S. adults who self-report good or better health. The Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health Scale (GHS) was identified as a reliable and valid set of items of self-reported physical and mental health to monitor these two domains across the decade. The purpose of this study was to examine the percentage of adults with an epilepsy history who met the Healthy People 2020 target for self-reported good or better health and to compare these percentages to adults with history of other common chronic conditions. Using the 2010 National Health Interview Survey, we compared and estimated the age-standardized prevalence of reporting good or better physical and mental health among adults with five selected chronic conditions including epilepsy, diabetes, heart disease, cancer, and hypertension. We examined response patterns for physical and mental health scale among adults with these five conditions. The percentages of adults with epilepsy who reported good or better physical health (52%) or mental health (54%) were significantly below the Healthy People 2020 target estimate of 80% for both outcomes. Significantly smaller percentages of adults with an epilepsy history reported good or better physical health than adults with heart disease, cancer, or hypertension. Significantly smaller percentages of adults with an epilepsy history reported good or better mental health than adults with all other four conditions. Health and social service providers can implement and enhance existing evidence-based clinical interventions and public health programs and strategies shown to improve outcomes in epilepsy. These estimates can be used to assess improvements in the Healthy People 2020 Health-Related Quality of Life and Well-Being Objective throughout the decade. Published by Elsevier Inc.

  20. A digital position-indication system for control rods

    International Nuclear Information System (INIS)

    Nishizawa, Yukio; Hayakawa, Toshifumi

    1979-01-01

    Systems that detect and indicate the position of the control rods that regulate the thermal output of a nuclear reactor play a particularly important role in monitoring its operational status. Conventionally, control rod position indication in pressurized water reactors has been of the analog type, utilizing the principle of the differential transformer. The present digital system was developed with the objective of achieving greater stability, greater accuracy, and higher reliability. The article gives a general description of the system and describes its advantages. (author)

  1. An electromechanical, patient positioning system for head and neck radiotherapy

    Science.gov (United States)

    Ostyn, Mark; Dwyer, Thomas; Miller, Matthew; King, Paden; Sacks, Rachel; Cruikshank, Ross; Rosario, Melvin; Martinez, Daniel; Kim, Siyong; Yeo, Woon-Hong

    2017-09-01

    In cancer treatment with radiation, accurate patient setup is critical for proper dose delivery. Improper arrangement can lead to disease recurrence, permanent organ damage, or lack of disease control. While current immobilization equipment often helps for patient positioning, manual adjustment is required, involving iterative, time-consuming steps. Here, we present an electromechanical robotic system for improving patient setup in radiotherapy, specifically targeting head and neck cancer. This positioning system offers six degrees of freedom for a variety of applications in radiation oncology. An analytical calculation of inverse kinematics serves as fundamental criteria to design the system. Computational mechanical modeling and experimental study of radiotherapy compatibility and x-ray-based imaging demonstrates the device feasibility and reliability to be used in radiotherapy. An absolute positioning accuracy test in a clinical treatment room supports the clinical feasibility of the system.

  2. Case report: a position to delineate pelvic radionuclide uptake

    International Nuclear Information System (INIS)

    Giga, J.H.L.; Jimenez, T.; Lobred, S.K.

    1981-01-01

    An innovative position is described for patients undergoing technetium 99m bone imaging in the pelvic area. The position, called Gaga squat, requires the patient to sit on the scintillation camera face. This allows recognition of metastatic disease in areas which may be masked by bladder activity. The view may also be used to complement conventional views for studies such as TcO 4 testicular scans or gallium-67 scans

  3. Global positioning method based on polarized light compass system

    Science.gov (United States)

    Liu, Jun; Yang, Jiangtao; Wang, Yubo; Tang, Jun; Shen, Chong

    2018-05-01

    This paper presents a global positioning method based on a polarized light compass system. A main limitation of polarization positioning is the environment such as weak and locally destroyed polarization environments, and the solution to the positioning problem is given in this paper which is polarization image de-noising and segmentation. Therefore, the pulse coupled neural network is employed for enhancing positioning performance. The prominent advantages of the present positioning technique are as follows: (i) compared to the existing position method based on polarized light, better sun tracking accuracy can be achieved and (ii) the robustness and accuracy of positioning under weak and locally destroyed polarization environments, such as cloudy or building shielding, are improved significantly. Finally, some field experiments are given to demonstrate the effectiveness and applicability of the proposed global positioning technique. The experiments have shown that our proposed method outperforms the conventional polarization positioning method, the real time longitude and latitude with accuracy up to 0.0461° and 0.0911°, respectively.

  4. Cam Mover Alignment System positioning with the Wire Positioning with the Wire Position Sensor Feedback for CLIC

    CERN Document Server

    AUTHOR|(CDS)2077936; Mainaud Durand, Helene; Kostka, Z.S.

    2016-01-01

    Compact Linear Collider (CLIC) is a study of an electron-positron collider with nominal energy of 3 TeV and luminosity of 2 ∙ 1034 cm-2s-1. The luminosity goal leads to stringent alignment requirements for single quadrupole magnets. Vertical and lateral offset deviations with regards to a given orbit reference in both ends of a quadrupole shall be below 1 μm and quadrupole roll deviation shall be below 100 μrad. Translation in the direction of particle beam is not controlled but mechanically locked. A parallel kinematic platform based on cam movers was chosen as system for detailed studies. Earlier studies have shown that cam movers can reach the CLIC requirements through an iterative process. The paper presents new modular off-the-shelf control electronics and software including three optional positioning algorithms based on iterations as well as a more advanced algorithm which can reach target position in one movement. The advanced algorithm reads wire position sensors (WPS), calculates quadrupole orien...

  5. Women's Status and World-System Position: An Exploratory Analysis

    Directory of Open Access Journals (Sweden)

    Richard York

    2015-08-01

    Full Text Available Our aim here is to strengthen the links between the world-systems perspective and research ongender inequality. Grounding our analysis in theories assessing the connections between genderrelationships and world-system processes, we empirically explore (] the extent to whichwomen's status in nations overlaps with the world-system position of those nations and (2 theinfluence of women's status within nations on a variety of national characteristics. We find thatwomen's status has a moderately strong association with world-system position, which suggeststhat macro-comparative research may confound the respective effects on a variety of socialcharacteristics of women's status and world-system position if indicators of both factors are notincluded in analyses. We also find that, controlling for world-system position, GDP per capita,and urbanization, in nations where women have higher status (variously measured, total fertilityrates, infant mortality rates, military expenditures, and inflows of foreign direct investinent arelower, and public health care expenditures and per capita meat consumption are higher. Theseresults suggest that women's status likely has social effects that can be seen on the macro-level,and that world-systems analysts should pay more attention to theories of gender in their research.

  6. Design of a positioning system for a holographic otoscope

    Science.gov (United States)

    Dobrev, I.; Flores Moreno, J. M.; Furlong, C.; Harrington, E. J.; Rosowski, J. J.; Scarpino, C.

    2010-08-01

    Current ear examination procedures provide mostly qualitative information which results in insufficient or erroneous description of the patient's hearing. Much more quantitative and accurate results can be achieved with a holographic otoscope system currently under development. Various ways of accurate positioning and stabilization of the system in real-life conditions are being investigated by this project in an attempt to bring this new technology to the hospitals and clinics, in order to improve the quality of the treatments and operations of the human ear. The project is focused at developing a mechatronic system capable of positioning the holographic otoscope to the patient's ear and maintaining its relative orientation during the examination. The system will be able to be guided by the examiner, but it will maintain the chosen position automatically. To achieve that, various trajectories are being measured for existing otoscopes being guided by doctors in real medical conditions. Based on that, various kinematic configurations are to be synthesized and their stability and accuracy will be simulated and optimized with FEA. For simplification, the mechanism will contain no actuators, but only adjustable friction elements in a haptic feedback control system. This renders the positioning system safe and easily applicable to current examination rooms. Other means of stabilization of the system are being investigated such as custom designed packaging of all of the otoscope subsystems, interferometrically compensating for the heartbeat induced vibration of the tympanic membrane as well as methods for monitoring and active response to the motion of the patient's head.

  7. An Autonomous Distributed Fault-Tolerant Local Positioning System

    Science.gov (United States)

    Malekpour, Mahyar R.

    2017-01-01

    We describe a fault-tolerant, GPS-independent (Global Positioning System) distributed autonomous positioning system for static/mobile objects and present solutions for providing highly-accurate geo-location data for the static/mobile objects in dynamic environments. The reliability and accuracy of a positioning system fundamentally depends on two factors; its timeliness in broadcasting signals and the knowledge of its geometry, i.e., locations and distances of the beacons. Existing distributed positioning systems either synchronize to a common external source like GPS or establish their own time synchrony using a scheme similar to a master-slave by designating a particular beacon as the master and other beacons synchronize to it, resulting in a single point of failure. Another drawback of existing positioning systems is their lack of addressing various fault manifestations, in particular, communication link failures, which, as in wireless networks, are increasingly dominating the process failures and are typically transient and mobile, in the sense that they typically affect different messages to/from different processes over time.

  8. Anti-Windup Scheme for Practical Control of Positioning Systems

    Directory of Open Access Journals (Sweden)

    Wahyudi Tarig Faisal and Abdulgani Albagul

    2012-10-01

    Full Text Available Positioning systems generally need a good controller to achieve high accuracy, fast response and robustness. In addition, ease of controller design and simplicity of controller structure are very important for practical application.  For satisfying these requirements, nominal characteristic trajectory following controller (NCTF has been proposed as a practical point-to-point (PTP positioning control. However, the effect of actuator saturation can not be completely compensated for due to the integrator windup as the plant parameters vary. This paper presents a method to improve the NCTF controller for overcoming the problem of integrator windup using simple and classical tracking anti-windup scheme. The improved NCTF controller is evaluated through simulation using a rotary positioning system. The results show that the improved NCTF controller is adequate to compensate for the effect of integrator windup. Keywords: Positioning, point-to-point, integrator windup, compensation, controller, robustness.

  9. Diffeomorphometry and geodesic positioning systems for human anatomy.

    Science.gov (United States)

    Miller, Michael I; Younes, Laurent; Trouvé, Alain

    2014-03-01

    The Computational Anatomy project has largely been a study of large deformations within a Riemannian framework as an efficient point of view for generating metrics between anatomical configurations. This approach turns D'Arcy Thompson's comparative morphology of human biological shape and form into a metrizable space. Since the metric is constructed based on the geodesic length of the flows of diffeomorphisms connecting the forms, we call it diffeomorphometry . Just as importantly, since the flows describe algebraic group action on anatomical submanifolds and associated functional measurements, they become the basis for positioning information, which we term geodesic positioning . As well the geodesic connections provide Riemannian coordinates for locating forms in the anatomical orbit, which we call geodesic coordinates . These three components taken together - the metric, geodesic positioning of information, and geodesic coordinates - we term the geodesic positioning system . We illustrate via several examples in human and biological coordinate systems and machine learning of the statistical representation of shape and form.

  10. Adverse Event Reporting System (AERS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Adverse Event Reporting System (AERS) is a computerized information database designed to support the FDA's post-marketing safety surveillance program for all...

  11. Vessel Electronic Reporting System (VERS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The VERS system is composed of a database and other related applications which facilitate the reporting of electronically collected research data via Fisheries...

  12. Positive periodic solutions of delayed periodic Lotka-Volterra systems

    International Nuclear Information System (INIS)

    Lin Wei; Chen Tianping

    2005-01-01

    In this Letter, for a general class of delayed periodic Lotka-Volterra systems, we prove some new results on the existence of positive periodic solutions by Schauder's fixed point theorem. The global asymptotical stability of positive periodic solutions is discussed further, and conditions for exponential convergence are given. The conditions we obtained are weaker than the previously known ones and can be easily reduced to several special cases

  13. Development of Precise Point Positioning Method Using Global Positioning System Measurements

    Directory of Open Access Journals (Sweden)

    Byung-Kyu Choi

    2011-09-01

    Full Text Available Precise point positioning (PPP is increasingly used in several parts such as monitoring of crustal movement and maintaining an international terrestrial reference frame using global positioning system (GPS measurements. An accuracy of PPP data processing has been increased due to the use of the more precise satellite orbit/clock products. In this study we developed PPP algorithm that utilizes data collected by a GPS receiver. The measurement error modelling including the tropospheric error and the tidal model in data processing was considered to improve the positioning accuracy. The extended Kalman filter has been also employed to estimate the state parameters such as positioning information and float ambiguities. For the verification, we compared our results to other of International GNSS Service analysis center. As a result, the mean errors of the estimated position on the East-West, North-South and Up-Down direction for the five days were 0.9 cm, 0.32 cm, and 1.14 cm in 95% confidence level.

  14. SPECTR System Operational Test Report

    International Nuclear Information System (INIS)

    Landman, W.H. Jr.

    2011-01-01

    This report overviews installation of the Small Pressure Cycling Test Rig (SPECTR) and documents the system operational testing performed to demonstrate that it meets the requirements for operations. The system operational testing involved operation of the furnace system to the design conditions and demonstration of the test article gas supply system using a simulated test article. The furnace and test article systems were demonstrated to meet the design requirements for the Next Generation Nuclear Plant. Therefore, the system is deemed acceptable and is ready for actual test article testing.

  15. The positioning system of the ANTARES Neutrino Telescope

    International Nuclear Information System (INIS)

    Adrián-Martínez, S; Ardid, M; Ageron, M; Samarai, I Al; Aubert, J-J; Bertin, V; Aguilar, J A; Albert, A; André, M; Anghinolfi, M; Anton, G; Anvar, S; Jesus, A C Assis; Astraatmadja, T; Baret, B; Basa, S; Biagi, S

    2012-01-01

    The ANTARES neutrino telescope, located 40 km off the coast of Toulon in the Mediterranean Sea at a mooring depth of about 2475 m, consists of twelve detection lines equipped typically with 25 storeys. Every storey carries three optical modules that detect Cherenkov light induced by charged secondary particles (typically muons) coming from neutrino interactions. As these lines are flexible structures fixed to the sea bed and held taut by a buoy, sea currents cause the lines to move and the storeys to rotate. The knowledge of the position of the optical modules with a precision better than 10 cm is essential for a good reconstruction of particle tracks. In this paper the ANTARES positioning system is described. It consists of an acoustic positioning system, for distance triangulation, and a compass-tiltmeter system, for the measurement of the orientation and inclination of the storeys. Necessary corrections are discussed and the results of the detector alignment procedure are described.

  16. The positioning system of the ANTARES Neutrino Telescope

    Science.gov (United States)

    Adrián-Martínez, S.; Ageron, M.; Aguilar, J. A.; Samarai, I. Al; Albert, A.; André, M.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Assis Jesus, A. C.; Astraatmadja, T.; Aubert, J.-J.; Baret, B.; Basa, S.; Bertin, V.; Biagi, S.; Bigi, A.; Bigongiari, C.; Bogazzi, C.; Bou-Cabo, M.; Bouhou, B.; Bouwhuis, M. C.; Brunner, J.; Busto, J.; Camarena, F.; Capone, A.; Cârloganu, C.; Carminati, G.; Carr, J.; Cecchini, S.; Charif, Z.; Charvis, Ph; Chiarusi, T.; Circella, M.; Coniglione, R.; Costantini, H.; Coyle, P.; Curtil, C.; De Bonis, G.; Decowski, M. P.; Dekeyser, I.; Deschamps, A.; Distefano, C.; Donzaud, C.; Dornic, D.; Dorosti, Q.; Drouhin, D.; Eberl, T.; Emanuele, U.; Enzenhöfer, A.; Ernenwein, J.-P.; Escoffier, S.; Fermani, P.; Ferri, M.; Flaminio, V.; Folger, F.; Fritsch, U.; Fuda, J.-L.; Galatà, S.; Gay, P.; Giacomelli, G.; Giordano, V.; Gómez-González, J. P.; Graf, K.; Guillard, G.; Halladjian, G.; Hallewell, G.; van Haren, H.; Hartman, J.; Heijboer, A. J.; Hello, Y.; Hernández-Rey, J. J.; Herold, B.; Hößl, J.; Hsu, C. C.; de Jong, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Katz, U.; Kavatsyuk, O.; Keller, P.; Kooijman, P.; Kopper, C.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lamare, P.; Larosa, G.; Lattuada, D.; Lefèvre, D.; Le Van Suu, A.; Lim, G.; Lo Presti, D.; Loehner, H.; Loucatos, S.; Mangano, S.; Marcelin, M.; Margiotta, A.; Martínez-Mora, J. A.; Meli, A.; Montaruli, T.; Moscoso, L.; Motz, H.; Neff, M.; Nezri, E.; Niess, V.; Palioselitis, D.; Păvălaş, G. E.; Payet, K.; Payre, P.; Petrovic, J.; Piattelli, P.; Picot-Clemente, N.; Popa, V.; Pradier, T.; Presani, E.; Racca, C.; Real, D.; Reed, C.; Riccobene, G.; Richardt, C.; Richter, R.; Rivière, C.; Robert, A.; Roensch, K.; Rostovtsev, A.; Ruiz-Rivas, J.; Rujoiu, M.; Russo, G. V.; Salesa, F.; Samtleben, D. F. E.; Schöck, F.; Schuller, J.-P.; Schüssler, F.; Seitz, T.; Shanidze, R.; Simeone, F.; Spies, A.; Spurio, M.; Steijger, J. J. M.; Stolarczyk, Th; Sánchez-Losa, A.; Taiuti, M.; Tamburini, C.; Toscano, S.; Vallage, B.; Van Elewyck, V.; Vannoni, G.; Vecchi, M.; Vernin, P.; Wagner, S.; Wijnker, G.; Wilms, J.; de Wolf, E.; Yepes, H.; Zaborov, D.; Zornoza, J. D.; Zúñiga, J.

    2012-08-01

    The ANTARES neutrino telescope, located 40 km off the coast of Toulon in the Mediterranean Sea at a mooring depth of about 2475 m, consists of twelve detection lines equipped typically with 25 storeys. Every storey carries three optical modules that detect Cherenkov light induced by charged secondary particles (typically muons) coming from neutrino interactions. As these lines are flexible structures fixed to the sea bed and held taut by a buoy, sea currents cause the lines to move and the storeys to rotate. The knowledge of the position of the optical modules with a precision better than 10 cm is essential for a good reconstruction of particle tracks. In this paper the ANTARES positioning system is described. It consists of an acoustic positioning system, for distance triangulation, and a compass-tiltmeter system, for the measurement of the orientation and inclination of the storeys. Necessary corrections are discussed and the results of the detector alignment procedure are described.

  17. Experimental Study on Position Control System Using Encoderless Magnetic Motion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Youn; Heo, Hoon [Korea Univ., Seoul (Korea, Republic of); Yun, Young Min; Shim, Ho Keun; Kwon, Young Mok [TPC Mechatronics, Daejeon (Korea, Republic of)

    2016-01-15

    A position control system composed of the PMLSM(Permanent Magnet Linear Synchronous Motor), unlike conventional linear permanent magnet synchronous motor is fixed to the permanent magnet moving coil rails (permanent magnet = stator, coil = mover), the coil is fixed, moving the permanent magnet, we propose a position control system (permanent magnet = mover, coil = stator) structure. Position is measured not using conventional encoder or resolver but by adopting vector control method using 2 hall sensors generating rectangular signal. This method estimate the velocity and position of mover by using the quadruple of two hall sensor signal instead of encoder signal. Vector control of PMLSM using 2 hall sensor generating rectangular wave is proved to control the system stable and efficiently through simulation. Also hardware experiment reveals that the position control performance is measured within the range of 30-50μ in the accuracy of 10-20μ, which is improved twice to the conventional method. The proposed method exhibits its economical efficiency and practical usefulness. The vector control technique using two hall sensors can be installed in narrow place, accordingly it can be implemented on the system where the conventional encoder or resolver cannot operate.

  18. Positive blood culture with Plasmodium falciparum : Case report

    NARCIS (Netherlands)

    De Vries, Jutte J. C.; Van Assen, Sander; Mulder, André B.; Kampinga, Greetje A.

    2007-01-01

    An adult traveler presented with fever and malaise after returning from Sierra Leone. Young trophozoites of Plasmodium falciparum were seen in a blood smear, with parasitemia being 10%. Moreover, blood cultures drawn on admission signaled as "positive" after 1 day of incubation, but no bacteria were

  19. A New Chaotic System with Positive Topological Entropy

    Directory of Open Access Journals (Sweden)

    Zhonglin Wang

    2015-08-01

    Full Text Available This paper introduces a new simple system with a butterfly chaotic attractor. This system has rich and complex dynamics. With some typical parameters, its Lyapunov dimension is greater than other known three dimensional chaotic systems. It exhibits chaotic behavior over a large range of parameters, and the divergence of flow of this system is not a constant. The dynamics of this new system are analyzed via Lyapunov exponent spectrum, bifurcation diagrams, phase portraits and the Poincaré map. The compound structures of this new system are also analyzed. By means of topological horseshoe theory and numerical computation, the Poincaré map defined for the system is proved to be semi-conjugate to 3-shift map, and thus the system has positive topological entropy.

  20. Discriminating between true-positive and false-positive clinical mastitis alerts from automatic milking systems

    NARCIS (Netherlands)

    Steeneveld, W.; Gaag, van der L.C.; Ouweltjes, W.; Mollenhorst, H.; Hogeveen, H.

    2010-01-01

    Automatic milking systems (AMS) generate alert lists reporting cows likely to have clinical mastitis (CM). Dutch farmers indicated that they use non-AMS cow information or the detailed alert information from the AMS to decide whether to check an alerted cow for CM. However, it is not yet known to

  1. Development of the 'JFT-2' tokamak plasma position control system

    International Nuclear Information System (INIS)

    Fujisawa, Noboru; Matsuzaki, Yoshimi; Suzuki, Norio; Murai, Katsuji; Suzuki, Satoshi.

    1980-01-01

    Digital control technique was applied to control the plasma position in the JFT-2 tokamak experiment device. The detail of the JFT-2 is described elsewhere. The plasma position control system consists of a Hitachi control computer, HIDIC 80, and a Hitachi micro-computer, HIDIC 08E. The plasma position is detected by the position control computer, and compared with a preset value. Then, a reference signal is supplied to the micro-computer controlling power source, and the phase control of the thyristor controlling power source is performed. Since the behavior of plasma is very fast, the fast control is required. The control of the thyristor controlling power source is made by direct digital control (DDC). The main component of the hardware of the present system is the micro-computer HIDIC 08E. The software is the direct task system without the operating system (OS). The results of experiments showed that the feedback control of the system worked well. (Kato, T.)

  2. Continuous, saturation, and discontinuous tokamak plasma vertical position control systems

    Energy Technology Data Exchange (ETDEWEB)

    Mitrishkin, Yuri V., E-mail: y_mitrishkin@hotmail.com [M. V. Lomonosov Moscow State University, Faculty of Physics, Moscow 119991 (Russian Federation); Pavlova, Evgeniia A., E-mail: janerigoler@mail.ru [M. V. Lomonosov Moscow State University, Faculty of Physics, Moscow 119991 (Russian Federation); Kuznetsov, Evgenii A., E-mail: ea.kuznetsov@mail.ru [Troitsk Institute for Innovation and Fusion Research, Moscow 142190 (Russian Federation); Gaydamaka, Kirill I., E-mail: k.gaydamaka@gmail.com [V. A. Trapeznikov Institute of Control Sciences of the Russian Academy of Sciences, Moscow 117997 (Russian Federation)

    2016-10-15

    Highlights: • Robust new linear state feedback control system for tokamak plasma vertical position. • Plasma vertical position relay control system with voltage inverter in sliding mode. • Design of full models of multiphase rectifier and voltage inverter. • First-order unit approximation of full multiphase rectifier model with high accuracy. • Wider range of unstable plant parameters of stable control system with multiphase rectifier. - Abstract: This paper is devoted to the design and comparison of unstable plasma vertical position control systems in the T-15 tokamak with the application of two types of actuators: a multiphase thyristor rectifier and a transistor voltage inverter. An unstable dynamic element obtained by the identification of plasma-physical DINA code was used as the plasma model. The simplest static feedback state space control law was synthesized as a linear combination of signals accessible to physical measurements, namely the plasma vertical displacement, the current, and the voltage in a horizontal field coil, to solve the pole placement problem for a closed-loop system. Only one system distinctive parameter was used to optimize the performance of the feedback system, viz., a multiple real pole. A first-order inertial unit was used as the rectifier model in the feedback. A system with a complete rectifier model was investigated as well. A system with the voltage inverter model and static linear controller was brought into a sliding mode. As this takes place, real time delays were taken into account in the discontinuous voltage inverter model. The comparison of the linear and sliding mode systems showed that the linear system enjoyed an essentially wider range of the plant model parameters where the feedback system was stable.

  3. Continuous, saturation, and discontinuous tokamak plasma vertical position control systems

    International Nuclear Information System (INIS)

    Mitrishkin, Yuri V.; Pavlova, Evgeniia A.; Kuznetsov, Evgenii A.; Gaydamaka, Kirill I.

    2016-01-01

    Highlights: • Robust new linear state feedback control system for tokamak plasma vertical position. • Plasma vertical position relay control system with voltage inverter in sliding mode. • Design of full models of multiphase rectifier and voltage inverter. • First-order unit approximation of full multiphase rectifier model with high accuracy. • Wider range of unstable plant parameters of stable control system with multiphase rectifier. - Abstract: This paper is devoted to the design and comparison of unstable plasma vertical position control systems in the T-15 tokamak with the application of two types of actuators: a multiphase thyristor rectifier and a transistor voltage inverter. An unstable dynamic element obtained by the identification of plasma-physical DINA code was used as the plasma model. The simplest static feedback state space control law was synthesized as a linear combination of signals accessible to physical measurements, namely the plasma vertical displacement, the current, and the voltage in a horizontal field coil, to solve the pole placement problem for a closed-loop system. Only one system distinctive parameter was used to optimize the performance of the feedback system, viz., a multiple real pole. A first-order inertial unit was used as the rectifier model in the feedback. A system with a complete rectifier model was investigated as well. A system with the voltage inverter model and static linear controller was brought into a sliding mode. As this takes place, real time delays were taken into account in the discontinuous voltage inverter model. The comparison of the linear and sliding mode systems showed that the linear system enjoyed an essentially wider range of the plant model parameters where the feedback system was stable.

  4. Augmentation of Quasi-Zenith Satellite Positioning System Using High Altitude Platforms Systems (HAPS)

    Science.gov (United States)

    Tsujii, Toshiaki; Harigae, Masatoshi

    Recently, some feasibility studies on a regional positioning system using the quasi-zenith satellites and the geostationary satellites have been conducted in Japan. However, the geometry of this system seems to be unsatisfactory in terms of the positioning accuracy in north-south direction. In this paper, an augmented satellite positioning system by the High Altitude Platform Systems (HAPS) is proposed since the flexibility of the HAPS location is effective to improve the geometry of satellite positioning system. The improved positioning performance of the augmented system is also demonstrated.

  5. Multistage position-stabilized vibration isolation system for neutron interferometry

    Science.gov (United States)

    Arif, Muhammad; Brown, Dennis E.; Greene, Geoffrey L.; Clothier, R.; Littrell, K.

    1994-10-01

    A two stage, position stabilized vibration isolation system has been constructed and is now in operation at the Cold Neutron Research Facility of the National Institute of Standards and Technology, Gaithersburg, MD. The system employs pneumatic isolators with a multiple input/multiple output pneumatic servo system based upon pulse width modulation control loops. The first stage consists of a 40,000 kg reinforced concrete table supported by pneumatic isolators. A large environmentally isolated laboratory enclosure rests on the concrete table. The second stage consists of a 3000 kg granite optical table located within the enclosure and supported by another set of pneumatic isolators. The position of the two stages is monitored by proximity sensors and inclinometers with 12 degrees of freedom. The system controls 12 independent pneumatic airsprings. The signals from these sensors are fed into a personal computer based control system. The control system has maintained the position of the two stages to better than 1 micrometers in translation and 5 (mu) rad in orientation for a period of a few months. A description of the system and its characteristics is given.

  6. Data analysis of inertial sensor for train positioning detection system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Jin; Park, Sung Soo; Lee, Jae Ho; Kang, Dong Hoon [Korea Railroad Research Institute, Uiwang (Korea, Republic of)

    2015-02-15

    Train positioning detection information is fundamental for high-speed railroad inspection, making it possible to simultaneously determine the status and evaluate the integrity of railroad equipment. This paper presents the results of measurements and an analysis of an inertial measurement unit (IMU) used as a positioning detection sensors. Acceleration and angular rate measurements from the IMU were analyzed in the amplitude and frequency domains, with a discussion on vibration and train motions. Using these results and GPS information, the positioning detection of a Korean tilting train express was performed from Naju station to Illo station on the Honam-line. The results of a synchronized analysis of sensor measurements and train motion can help in the design of a train location detection system and improve the positioning detection performance.

  7. Stability of position control system in JIPP T-II

    International Nuclear Information System (INIS)

    Sakurai, Keiichi; Tanahashi, Shygo

    1980-01-01

    Computations and experiments on the stability of a feedback control system for maintaining a plasma column in equilibrium are described. The time response of the displacement of the plasma to the desired position is examined by solving the equation of motion of the plasma column. We show that the stability of the feedback control system is improved by using an additional term which represents the shift velocity of the plasma column. (author)

  8. CAVITY BEAM POSITION MONITOR SYSTEM FOR ATF2

    CERN Document Server

    Boogert, S T; Boorman, G; Molloy, S; Ross, M; Aryshev, A; Honda, Y; Terunuma, N; Urakawa, J; Kim, E S; Kim, Y I; Heo, A E; Lyapin, A; Swinson, C J; Frisch, J; McCormick, D M; Nelson, J; Smith, T; White, G R

    2010-01-01

    The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance.

  9. Helicopter precision approach capability using the Global Positioning System

    Science.gov (United States)

    Kaufmann, David N.

    1992-01-01

    The period between 1 July and 31 December, 1992, was spent developing a research plan as well as a navigation system document and flight test plan to investigate helicopter precision approach capability using the Global Positioning System (GPS). In addition, all hardware and software required for the research was acquired, developed, installed, and verified on both the test aircraft and the ground-based reference station.

  10. Distributed stabilisation of spatially invariant systems: positive polynomial approach

    Czech Academy of Sciences Publication Activity Database

    Augusta, Petr; Hurák, Z.

    2013-01-01

    Roč. 24, Č. 1 (2013), s. 3-21 ISSN 1573-0824 R&D Projects: GA MŠk(CZ) 1M0567 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : Multidimensional systems * Algebraic approach * Control design * Positiveness Subject RIV: BC - Control Systems Theory http://library.utia.cas.cz/separaty/2013/TR/augusta-0382623.pdf

  11. Symmetric positive differential equations and first order hyperbolic systems

    International Nuclear Information System (INIS)

    Tangmanee, S.

    1981-12-01

    We prove that under some conditions the first order hyperbolic system and its associated mixed initial boundary conditions considered, for example, in Kreiss (Math. Comp. 22, 703-704 (1968)) and Kreiss and Gustafsson (Math. Comp. 26, 649-686 (1972)), can be transformed into a symmetric positive system of P.D.E.'s with admissible boundary conditions of Friedrich's type (Comm. Pure Appl. Math 11, 333-418 (1958)). (author)

  12. Indoor Positioning and Monitoring System Using Smartphone and WLAN (IPMS

    Directory of Open Access Journals (Sweden)

    Hamid Mohammed Ali

    2015-09-01

    Full Text Available Buildings such as malls, offices, airports and hospitals nowadays have become very complicated which increases the need for a solution that helps people to find their locations in these buildings. GPS or cell signals are commonly used for positioning in an outdoor environment and are not accurate in indoor environment. Smartphones are becoming a common presence in our daily life, also the existing infrastructure, the Wi-Fi access points, which is commonly available in most buildings, has motivated this work to build hybrid mechanism that combines the APs fingerprint together with smartphone barometer sensor readings, to accurately determine the user position inside building floor relative to well-known landmarks in the floor. Also the proposed system offers a monitoring activity which lets the administrator to watch and locate certain user inside the building.The system is tested in a big building indoor environment and achieved positioning accuracies of approximately 2.1 meters.

  13. 2014 Runtime Systems Summit. Runtime Systems Report

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, Vivek [US Dept. of Energy, Washington, DC (United States); Budimlic, Zoran [US Dept. of Energy, Washington, DC (United States); Kulkani, Milind [US Dept. of Energy, Washington, DC (United States)

    2016-09-19

    This report summarizes runtime system challenges for exascale computing, that follow from the fundamental challenges for exascale systems that have been well studied in past reports, e.g., [6, 33, 34, 32, 24]. Some of the key exascale challenges that pertain to runtime systems include parallelism, energy efficiency, memory hierarchies, data movement, heterogeneous processors and memories, resilience, performance variability, dynamic resource allocation, performance portability, and interoperability with legacy code. In addition to summarizing these challenges, the report also outlines different approaches to addressing these significant challenges that have been pursued by research projects in the DOE-sponsored X-Stack and OS/R programs. Since there is often confusion as to what exactly the term “runtime system” refers to in the software stack, we include a section on taxonomy to clarify the terminology used by participants in these research projects. In addition, we include a section on deployment opportunities for vendors and government labs to build on the research results from these projects. Finally, this report is also intended to provide a framework for discussing future research and development investments for exascale runtime systems, and for clarifying the role of runtime systems in exascale software.

  14. A Method for The Assessing of Reliability Characteristics Relevant to an Assumed Position-Fixing Accuracy in Navigational Positioning Systems

    Directory of Open Access Journals (Sweden)

    Specht Cezary

    2016-09-01

    Full Text Available This paper presents a method which makes it possible to determine reliability characteristics of navigational positioning systems, relevant to an assumed value of permissible error in position fixing. The method allows to calculate: availability , reliability as well as operation continuity of position fixing system for an assumed, determined on the basis of formal requirements - both worldwide and national, position-fixing accuracy. The proposed mathematical model allows to satisfy, by any navigational positioning system, not only requirements as to position-fixing accuracy of a given navigational application (for air , sea or land traffic but also the remaining characteristics associated with technical serviceability of a system.

  15. The Evolution of Global Positioning System (GPS) Technology.

    Science.gov (United States)

    Kumar, Sameer; Moore, Kevin B.

    2002-01-01

    Describes technological advances in the Global Positioning System (GPS), which is also known as the NAVSTAR GPS satellite constellation program developed in 1937, and changes in the nature of our world by GPS in the areas of agriculture, health, military, transportation, environment, wildlife biology, surveying and mapping, space applications, and…

  16. Algorithms for Indoor Positioning Systems Using Ultra-Wideband Signals

    NARCIS (Netherlands)

    Yan, J.

    2010-01-01

    Positioning systems and techniques have attracted more and more attention in recent years, in particular with satellite navigation technology as a tremendous enabler, and developments in indoor navigation. The work presented in this thesis has been conducted within the research project: \\HERE:

  17. Multiple applications of the Boussignac continuous positive airway pressure system

    NARCIS (Netherlands)

    Dieperink, Willem

    2008-01-01

    Continuous positive airway pressure, (CPAP) is a form of treatment to support patients with dyspnea. For the application of CPAP a mechanical ventilator or complex CPAP apparatus is mostly used. The Boussignac CPAP (BCPAP) system developed by George Boussignac does not need such apparatus. The BCPAP

  18. Structure of the automatic system for plasma equilibrium position control

    International Nuclear Information System (INIS)

    Gubarev, V.F.; Krivonos, Yu.G.; Samojlenko, Yu.I.; Snegur, A.A.

    1978-01-01

    Considered are the principles of construction of the automatic system for plasma filament equilibrium position control inside the discharge chamber for the installation of a tokamak type. The combined current control system in control winding is suggested. The most powerful subsystem creates current in the control winding according to the program calculated beforehand. This system provides plasma rough equilibrium along the ''big radius''. The subsystem performing the current change in small limits according to the principle of feed-back coupling is provided simultaneously. The stabilization of plasma position is achieved in the discharge chamber. The advantage of construction of such system is in decreasing of the automatic requlator power without lowering the requirements to the accuracy of equilibrium preservation. The subsystem of automatic control of plasma position over the vertical is put into the system. Such an approach to the construction of the automatic control system proves to be correct; it is based on the experience of application of similar devices for some existing thermonuclear plants

  19. Determination of global positioning system (GPS) receiver clock errors: impact on positioning accuracy

    International Nuclear Information System (INIS)

    Yeh, Ta-Kang; Hwang, Cheinway; Xu, Guochang; Wang, Chuan-Sheng; Lee, Chien-Chih

    2009-01-01

    Enhancing the positioning precision is the primary pursuit of global positioning system (GPS) users. To achieve this goal, most studies have focused on the relationship between GPS receiver clock errors and GPS positioning precision. This study utilizes undifferentiated phase data to calculate GPS clock errors and to compare with the frequency of cesium clock directly, to verify estimated clock errors by the method used in this paper. The frequency stability calculated from this paper (the indirect method) and measured from the National Standard Time and Frequency Laboratory (NSTFL) of Taiwan (the direct method) match to 1.5 × 10 −12 (the value from this study was smaller than that from NSTFL), suggesting that the proposed technique has reached a certain level of quality. The built-in quartz clocks in the GPS receivers yield relative frequency offsets that are 3–4 orders higher than those of rubidium clocks. The frequency stability of the quartz clocks is on average two orders worse than that of the rubidium clock. Using the rubidium clock instead of the quartz clock, the horizontal and vertical positioning accuracies were improved by 26–78% (0.6–3.6 mm) and 20–34% (1.3–3.0 mm), respectively, for a short baseline. These improvements are 7–25% (0.3–1.7 mm) and 11% (1.7 mm) for a long baseline. Our experiments show that the frequency stability of the clock, rather than relative frequency offset, is the governing factor of positioning accuracy

  20. Final report: U.S. competitive position in automotive technologies

    Energy Technology Data Exchange (ETDEWEB)

    Albert, Michael B.; Cheney, Margaret; Thomas, Patrick; Kroll, Peter

    2002-09-30

    Patent data are presented and analyzed to assess the U.S. competitive position in eleven advanced automotive technology categories, including automotive fuel cells, hydrogen storage, advanced batteries, hybrid electric vehicles and others. Inventive activity in most of the technologies is found to be growing at a rapid pace, particularly in advanced batteries, automotive fuel cells and ultracapacitors. The U.S. is the clear leader in automotive fuel cells, on-board hydrogen storage and light weight materials. Japan leads in advanced batteries, hybrid electric vehicles, ultracapacitors, and appears to be close to overtaking the U.S. in other areas of power electronics.

  1. Technique for Increasing Accuracy of Positioning System of Machine Tools

    Directory of Open Access Journals (Sweden)

    Sh. Ji

    2014-01-01

    Full Text Available The aim of research is to improve the accuracy of positioning and processing system using a technique for optimization of pressure diagrams of guides in machine tools. The machining quality is directly related to its accuracy, which characterizes an impact degree of various errors of machines. The accuracy of the positioning system is one of the most significant machining characteristics, which allow accuracy evaluation of processed parts.The literature describes that the working area of the machine layout is rather informative to characterize the effect of the positioning system on the macro-geometry of the part surfaces to be processed. To enhance the static accuracy of the studied machine, in principle, two groups of measures are possible. One of them points toward a decrease of the cutting force component, which overturns the slider moments. Another group of measures is related to the changing sizes of the guide facets, which may lead to their profile change.The study was based on mathematical modeling and optimization of the cutting zone coordinates. And we find the formula to determine the surface pressure of the guides. The selected parameters of optimization are vectors of the cutting force and values of slides and guides. Obtained results show that a technique for optimization of coordinates in the cutting zone was necessary to increase a processing accuracy.The research has established that to define the optimal coordinates of the cutting zone we have to change the sizes of slides, value and coordinates of applied forces, reaching the pressure equalization and improving the accuracy of positioning system of machine tools. In different points of the workspace a vector of forces is applied, pressure diagrams are found, which take into account the changes in the parameters of positioning system, and the pressure diagram equalization to provide the most accuracy of machine tools is achieved.

  2. Launch vehicle tracking enhancement through Global Positioning System Metric Tracking

    Science.gov (United States)

    Moore, T. C.; Li, Hanchu; Gray, T.; Doran, A.

    United Launch Alliance (ULA) initiated operational flights of both the Atlas V and Delta IV launch vehicle families in 2002. The Atlas V and Delta IV launch vehicles were developed jointly with the US Air Force (USAF) as part of the Evolved Expendable Launch Vehicle (EELV) program. Both Launch Vehicle (LV) families have provided 100% mission success since their respective inaugural launches and demonstrated launch capability from both Vandenberg Air Force Base (VAFB) on the Western Test Range and Cape Canaveral Air Force Station (CCAFS) on the Eastern Test Range. However, the current EELV fleet communications, tracking, & control architecture & technology, which date back to the origins of the space launch business, require support by a large and high cost ground footprint. The USAF has embarked on an initiative known as Future Flight Safety System (FFSS) that will significantly reduce Test Range Operations and Maintenance (O& M) cost by closing facilities and decommissioning ground assets. In support of the FFSS, a Global Positioning System Metric Tracking (GPS MT) System based on the Global Positioning System (GPS) satellite constellation has been developed for EELV which will allow both Ranges to divest some of their radar assets. The Air Force, ULA and Space Vector have flown the first 2 Atlas Certification vehicles demonstrating the successful operation of the GPS MT System. The first Atlas V certification flight was completed in February 2012 from CCAFS, the second Atlas V certification flight from VAFB was completed in September 2012 and the third certification flight on a Delta IV was completed October 2012 from CCAFS. The GPS MT System will provide precise LV position, velocity and timing information that can replace ground radar tracking resource functionality. The GPS MT system will provide an independent position/velocity S-Band telemetry downlink to support the current man-in-the-loop ground-based commanded destruct of an anomalous flight- The system

  3. Resolution of a High Performance Cavity Beam Position Monitor System

    International Nuclear Information System (INIS)

    Walston, S.; Chung, C.; Fitsos, P.; Gronberg, J.; Ross, M.; Khainovski, O.; Kolomensky, Y.; Loscutoff, P.; Slater, M.; Thomson, M.; Ward, D.; Boogert, S.; Vogel, V.; Meller, R.; Lyapin, A.; Malton, S.; Miller, D.; Frisch, J.; Hinton, S.; May, J.; McCormick, D.; Smith, S.; Smith, T.; White, G.; Orimoto, T.; Hayano, H.; Honda, Y.; Terunuma, N.; Urakawa, J.

    2005-01-01

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved - ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. A metrology system for the three BPMs was recently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame and has demonstrated that the three BPMs behave as a rigid-body to less than 5 nm. To date, we have demonstrated a BPM resolution of less than 20 nm over a dynamic range of +/- 20 microns

  4. Flat Top Barge 300 feet Using Portable Dynamic Positioning System

    Directory of Open Access Journals (Sweden)

    Agoes Santoso

    2017-03-01

    Full Text Available Portable Dynamic Positioning System has not commonly applied to the ship, especially on barge. Besides for Dynamic Positioning function, the system can be used as ship's main propulsion. By using this system, the ship able to not using anchors because the functions can be performed by the Portable Dynamic System. Therefore, research about the application of Portable Dynamic Positioning System on the ship is conducted. This research aims to design a Flat Top Barge 300feet ship, to determine the specifications of Portable Dynamic Positioning System which is used, and to find out the ship stability which is designed on the empty payload condition and maximum payload. This research designed the ships with main dimensions LWL 90.1 meters, 25 meters wide, 5.5 meters high and 4.2 meters draught. To generate the ship with a maximum speed of 8 knots, it takes four thruster supplied with power 225 kW each, so that the total generated power is 1100 kW. This study analyzes three conditions of the ship stability, there are the condition of full payload, empty payload, and maximum payload. Each payload conditions will be analyzed regarding the large payload and draught water produced. The first is full payload conditions resulting payload in the amount of 5650 ton with a draught on the LCF at 4,181 meters. The second is the large empty payload condition displacement is 2809 ton and water draught on the LCF at 1,591. And the last is maximum payload conditions, resulting payload in the amount of 7450 ton with a draught on the LCF at 4,994 meters.

  5. Lateral position detection and control for friction stir systems

    Science.gov (United States)

    Fleming, Paul; Lammlein, David; Cook, George E.; Wilkes, Don Mitchell; Strauss, Alvin M.; Delapp, David; Hartman, Daniel A.

    2010-12-14

    A friction stir system for processing at least a first workpiece includes a spindle actuator coupled to a rotary tool comprising a rotating member for contacting and processing the first workpiece. A detection system is provided for obtaining information related to a lateral alignment of the rotating member. The detection system comprises at least one sensor for measuring a force experienced by the rotary tool or a parameter related to the force experienced by the rotary tool during processing, wherein the sensor provides sensor signals. A signal processing system is coupled to receive and analyze the sensor signals and determine a lateral alignment of the rotating member relative to a selected lateral position, a selected path, or a direction to decrease a lateral distance relative to the selected lateral position or selected path. In one embodiment, the friction stir system can be embodied as a closed loop tracking system, such as a robot-based tracked friction stir welding (FSW) or friction stir processing (FSP) system.

  6. Position paper -- Tank ventilation system design air flow rates

    International Nuclear Information System (INIS)

    Goolsby, G.K.

    1995-01-01

    The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960 scfm and 4,400 scfm, respectively, per tank. These design flow rates were capable of removing 1,250,000 Btu/hr from each tank. However, recently completed and ongoing studies have resulted in a design change to reduce the extreme case heat load to 700,000 Btu/hr. This revision of the extreme case heat load, coupled with results of scale model evaporative testing performed by WHC Thermal Hydraulics, allow for a reduction of the design air flow rates for both primary and annulus ventilation systems. Based on the preceding discussion, ICF Kaiser Hanford Co. concludes that the design should incorporate the following design air flow rates: Primary ventilation system--500 scfm maximum and Annulus ventilation system--1,100 scfm maximum. In addition, the minimum air flow rates in the primary and annulus ventilation systems will be investigated during Title 2 design. The results of the Title 2 investigation will determine the range of available temperature control using variable air flows to both ventilation systems

  7. Experimental lithium system. Final report

    International Nuclear Information System (INIS)

    Kolowith, R.; Berg, J.D.; Miller, W.C.

    1985-04-01

    A full-scale mockup of the Fusion Materials Irradiation Test (FMIT) Facility lithium system was built at the Hanford Engineering Development Laboratory (HEDL). This isothermal mockup, called the Experimental Lithium System (ELS), was prototypic of FMIT, excluding the accelerator and dump heat exchanger. This 3.8 m 3 lithium test loop achieved over 16,000 hours of safe and reliable operation. An extensive test program demonstrated satisfactory performance of the system components, including the HEDL-supplied electromagnetic lithium pump, the lithium jet target, the purification and characterization hardware, as well as the auxiliary argon and vacuum systems. Experience with the test loop provided important information on system operation, performance, and reliability. This report presents a complete overview of the entire Experimental Lithium System test program and also includes a summary of such areas as instrumentation, coolant chemistry, vapor/aerosol transport, and corrosion

  8. Control system design for nano-positioning using piezoelectric actuators

    International Nuclear Information System (INIS)

    Shan, Jinjun; Liu, Yanfang; Cui, Naigang; Gabbert, Ulrich

    2016-01-01

    This paper presents a systematic control system design for nano-positioning of a piezoelectric actuator (PEA). PEAs exhibit hysteresis nonlinearity, which can dramatically limit the application and performance of linear feedback control theory. Thus the hysteresis is compensated for based on the Maxwell resistive capacitor (MRC) model first. Then a proportional plus integral (PI) controller and a proportional double integral plus lead compensation (PII and L) controller are designed for the hysteresis-compensated PEA to account for model uncertainty, disturbance, and noise. The robust stability of both controllers is proved. The effectiveness of the proposed control scheme is demonstrated experimentally. Both controllers achieve fast precise positioning. The 2% settling times for the PI controller and the PII and L controller are 1.5 ms and 4.7 ms, respectively. The positioning resolution is upto 1 nm for both controllers. (paper)

  9. A novel wireless local positioning system for airport (indoor) security

    Science.gov (United States)

    Zekavat, Seyed A.; Tong, Hui; Tan, Jindong

    2004-09-01

    A novel wireless local positioning system (WLPS) for airport (or indoor) security is introduced. This system is used by airport (indoor) security guards to locate all of, or a group of airport employees or passengers within the airport area. WLPS consists of two main parts: (1) a base station that is carried by security personnel; hence, introducing dynamic base station (DBS), and (2) a transponder (TRX) that is mounted on all people (including security personnel) present at the airport; thus, introducing them as active targets. In this paper, we (a) draw a futuristic view of the airport security systems, and the flow of information at the airports, (b) investigate the techniques of extending WLPS coverage area beyond the line-of-sight (LoS), and (c) study the performance of this system via standard transceivers, and direct sequence code division multiple access (DS-CDMA) systems with and without antenna arrays and conventional beamforming (BF).

  10. GPS-based satellite tracking system for precise positioning

    Science.gov (United States)

    Yunck, T. P.; Melbourne, W. G.; Thornton, C. L.

    1985-01-01

    NASA is developing a Global Positioning System (GPS) based measurement system to provide precise determination of earth satellite orbits, geodetic baselines, ionospheric electron content, and clock offsets between worldwide tracking sites. The system will employ variations on the differential GPS observing technique and will use a network of nine fixed ground terminals. Satellite applications will require either a GPS flight receiver or an on-board GPS beacon. Operation of the system for all but satellite tracking will begin by 1988. The first major satellite application will be a demonstration of decimeter accuracy in determining the altitude of TOPEX in the early 1990's. By then the system is expected to yield long-baseline accuracies of a few centimeters and instantaneous time synchronization to 1 ns.

  11. Beam position feedback system for the advanced photon source

    International Nuclear Information System (INIS)

    Chung, Y.

    1994-01-01

    The Advanced Photon Source (APS) will implement both global and local beam position feedback systems to stabilize the particle and x-ray beams for the storage ring. The systems consist of 20 VME crates distributed around the ring, each running multiple digital signal processors (DSP) running at 4 kHz sampling rate with a proportional, integral, and derivative (PID) control algorithm. The particle and x-ray beam position data is shared by the distributed processors through networked reflective memory. A theory of closed orbit correction using the technique of singular value decomposition (SVD) of the response matrix and simulation of its application to the APS storage ring will be discussed. This technique combines the global and local feedback systems and resolves the conflict among multiple local feedback systems due to local bump closure error. Maximum correction efficiency is achieved by feeding back to the global orbit data to the local feedback systems. The effect of the eddy current induced in the relatively thick (1/2 in.) vacuum chamber by the ac corrector magnet field for local feedback systems is compensated by digital filters. Results of experiments conducted on the x-ray ring of the National Synchrotron Light Source and the SPEAR at Stanford Synchrotron Radiation Laboratory will also be presented

  12. Beam position feedback system for the advanced photon source

    International Nuclear Information System (INIS)

    Chung, Y.

    1994-01-01

    The Advanced Photon Source (APS) will implement both global and local beam position feedback systems to stabilize the particle and X-ray beams for the storage ring. The systems consist of 20 VME crates distributed around the ring, each running multiple digital signal processors (DSP) running at 4 kHz sampling rate with a proportional, integral, and derivative (PID) control algorithm. The particle and X-ray beam position data is shared by the distributed processors through networked reflective memory. A theory of closed orbit correction using the technique of singular value decomposition (SVD) of the response matrix and simulation of its application to the APS storage ring will be discussed. This technique combines the global and local feedback systems and resolves the conflict among multiple local feedback systems due to local bump closure error. Maximum correction efficiency is achieved by feeding back the global orbit data to the local feedback systems. The effect of the vacuum chamber eddy current induced by the AC corrector magnet field for local feedback systems is compensated by digital filters. Results of experiments conducted on the X-ray ring of the National Synchrotron Light Source and the SPEAR at Stanford Synchrotron Radiation Laboratory will be presented. copyright 1994 American Institute of Physics

  13. Beam position feedback system for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Chung, Y.

    1993-01-01

    The Advanced Photon Source (APS) will implement both global and local beam position feedback systems to stabilize the particle and X-ray beams for the storage ring. The systems consist of 20 VME crates distributed around the ring, each running multiple digital signal processors (DSP) running at 4kHz sampling rate with a proportional, integral, and derivative (PID) control algorithm. The particle and X-ray beam position data is shared by the distributed processors through networked reflective memory. A theory of closed orbit correction using the technique of singular value decomposition (SVD) of the response matrix and simulation of its application to the APS storage ring will be discussed. This technique combines the global and local feedback systems and resolves the conflict among multiple local feedback systems due to local bump closure error. Maximum correction efficiency is achieved by feeding back the global orbit data to the local feedback systems. The effect of the vacuum chamber eddy current induced by the AC corrector magnet field for local feedback systems is compensated by digital filters. Results of experiments conducted on the X-ray ring of the National Synchrotron Light Source and the SPEAR at Stanford Synchrotron Radiation Laboratory will be presented

  14. Beam position feedback system for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Chung, Y.

    1993-01-01

    The Advanced Photon Source (APS) will implement both global and local beam position feedback systems to stabilize the particle and X-ray beams for the storage ring. The systems consist of 20 VME crates distributed around the ring, each running multiple digital signal processors (DSP) running at 4kHz sampling rate with a proportional, integral, and derivative (PID) control algorithm. The particle and X-ray beam position data is shared by the distributed processors through networked reflective memory. A theory of closed orbit correction using the technique of singular value decomposition (SVD) of the response matrix and simulation of its application to the APS storage ring will be discussed. This technique combines the global and local feedback systems and resolves the conflict among multiple local feedback systems due to local bump closure error. Maximum correction efficiency is achieved by feeding back the global orbit data to the local feedback systems. The effect of the eddy current induced in the relatively thick (1/2 inch) vacuum chamber by the AC corrector magnet field for local feedback systems is compensated by digital filters. Results of experiments conducted on the X-ray ring of the National Synchrotron Light Source and the SPEAR at Stanford Synchrotron Radiation Laboratory will also be presented

  15. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    Science.gov (United States)

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  16. Subscriber Response System. Progress Report.

    Science.gov (United States)

    Callais, Richard T.

    Results of preliminary tests made prior and subsequent to the installation of a two-way interactive communication system which involves a computer complex termed the Local Processing Center and subscriber terminals located in the home or business location are reported. This first phase of the overall test plan includes tests made at Theta-Com…

  17. NASA aviation safety reporting system

    Science.gov (United States)

    1981-01-01

    Aviation safety reports that relate to loss of control in flight, problems that occur as a result of similar sounding alphanumerics, and pilot incapacitation are presented. Problems related to the go around maneuver in air carrier operations, and bulletins (and FAA responses to them) that pertain to air traffic control systems and procedures are included.

  18. The NSTX Trouble Reporting System

    International Nuclear Information System (INIS)

    Sengupta, S.; Oliaro, G.

    2002-01-01

    An online Trouble Reporting System (TRS) has been introduced at the National Spherical Torus Experiment (NSTX). The TRS is used by NSTX operators to report problems that affect NSTX operations. The purpose of the TRS is to enhance NSTX reliability and maintainability by identifying components, occurrences, and trends that contribute to machine downtime. All NSTX personnel have access to the TRS. The user interface is via a web browser, such as Netscape or Internet Explorer. This web-based feature permits any X-terminal, PC, or MAC access to the TRS. The TRS is based upon a trouble reporting system developed at the DIII-D Tokamak, at General Atomics Technologies. This paper will provide a detailed description of the TRS software architecture, user interface, MS SQL server interface and operational experiences. In addition, sample data from the TRS database will be summarized and presented

  19. Current position on software for the automatic data acquisition system

    International Nuclear Information System (INIS)

    1988-01-01

    This report describes the current concepts for software to control the operation of the Automatic Data Acquisition System (ADAS) proposed for the Deaf Smith County, Texas, Exploratory Shaft Facility (ESF). The purpose of this report is to provide conceptual details of how the ADAS software will execute the data acquisition function, and how the software will make collected information available to the test personnel, the Data Management Group (DMG), and other authorized users. It is not intended that this report describe all of the ADAS functions in exact detail, but the concepts included herein will form the basis for the formal ADAS functional requirements definition document. 5 refs., 14 figs

  20. Intensity position modulation for free-space laser communication system

    Science.gov (United States)

    Jangjoo, Alireza; Faghihi, F.

    2004-12-01

    In this research a novel modulation technique for free-space laser communication system called Intensity Position Modulation (IPM) is carried out. According to TEM00 mode of a laser beam and by linear fitting on the Gaussian function as an approximation, the variation of linear part on the reverse biased pn photodiode produced alternating currents which contain the information. Here, no characteristic property of the beam as intensity or frequency is changed and only the beam position moves laterally. We demonstrated that in this method no bandwidth is required, so it is possible to reduce the background radiation noise by narrowband filtering of the carrier. The fidelity of the analog voice communication system which is made upon the IPM is satisfactory and we are able to transmit the audio signals up to 1Km.

  1. Advanced control of piezoelectric micro-nano-positioning systems

    CERN Document Server

    Xu, Qingsong

    2016-01-01

    This book explores emerging methods and algorithms that enable precise control of micro-/nano-positioning systems. The text describes three control strategies: hysteresis-model-based feedforward control and hysteresis-model-free feedback control based on and free from state observation. Each paradigm receives dedicated attention within a particular part of the text. Readers are shown how to design, validate and apply a variety of new control approaches in micromanipulation: hysteresis modelling, discrete-time sliding-mode control and model-reference adaptive control. Experimental results are provided throughout and build up to a detailed treatment of practical applications in the fourth part of the book. The applications focus on control of piezoelectric grippers. Advanced Control of Piezoelectric Micro-/Nano-Positioning Systems will assist academic researchers and practising control and mechatronics engineers interested in suppressing sources of nonlinearity such as hysteresis and drift when combining positi...

  2. Ambiguity resolution in systems using Omega for position location

    Science.gov (United States)

    Frenkel, G.; Gan, D. G.

    1974-01-01

    The lane ambiguity problem prevents the utilization of the Omega system for many applications such as locating buoys and balloons. The method of multiple lines of position introduced herein uses signals from four or more Omega stations for ambiguity resolution. The coordinates of the candidate points are determined first through the use of the Newton iterative procedure. Subsequently, a likelihood function is generated for each point, and the ambiguity is resolved by selecting the most likely point. The method was tested through simulation.

  3. Design of the AGS Booster beam position monitor system

    International Nuclear Information System (INIS)

    Beadle, E.; Brennan, J.M.; Ciardullo, D.J.; Savino, J.; Stanziani, V.; Thomas, R.; Van Zwienen, W.; Witkover, R.L.; Schulte, E.

    1989-01-01

    The AGS Booster beam position monitor system must cover a wide range of beam intensity and bunch length for proton and heavy ion acceleration. The detector is designed to maintain 0.1 mm local tolerance following 300 degree C bakeout. The electronics will be located in the tunnel, communicating via fiber optic links to avoid ground loops. The design will be described and test results for prototype units presented. 5 refs., 4 figs

  4. CAVITY BEAM POSITION MONITOR SYSTEM FOR ATF2

    CERN Document Server

    Boogert, S T; Cullinan, F; Joshi, N; Lyapin, A; Aryshev, A; Honda, Y; Naito, T; Terunuma, N; Urakara, J; Heo, A; Kim, E-S; Kim, Y I; McCormick, D; Frisch, J; Nelson, J; Smith, T; White, G R

    2011-01-01

    The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 41 high resolution C and S band resonant cavity beam position monitors (BPM) with associated mixer electronics and digitisers. In addition 4 high resolution BPMs have been recently installed at the interaction point, we briefly describe the first operational experience of these cavities in the ATF2 beam-line. The current status of the overall BPM system is also described, with a focus on operational techniques and performance.

  5. Six movements measurement system employed for GAIA secondary mirror positioning system vacuum tests at cryogenic temperatures

    Science.gov (United States)

    Ramos Zapata, Gonzalo; Sánchez Rodríguez, Antonio; Garranzo García-Ibarrola, Daniel; Belenguer Dávila, Tomás

    2008-07-01

    In this work, the optical measurement system employed to evaluate the performance of a 6 degrees of freedom (dof) positioning mechanism under cryogenic conditions is explored. The mechanism, the flight model of three translations and three rotations positioning mechanism, was developed by the Spanish company SENER (for ASTRIUM) to fulfil the high performance requirements from ESA technology preparatory program for the positioning of a secondary mirror within the GAIA Astrometric Mission. Its performance has been evaluated under vacuum and temperature controlled conditions (up to a 10-6mbar and 100K) at the facilities of the Space Instrumentation Laboratory (LINES) of the Aerospace Technical Nacional Institute of Spain (INTA). After the description of the 'alignment tool' developed to compare a fixed reference with the optical signal corresponding to the movement under evaluation, the optical system that allows measuring the displacements and the rotations in the three space directions is reported on. Two similar bread-boards were defined and mounted for the measurements purpose, one containing two distancemeters, in order to measure the displacements through the corresponding axis, and an autocollimator in order to obtain the rotations on the plane whose normal vector is the axis mentioned before, and other one containing one distancemeter and one autocollimator. Both distancemeter and autocollimator measurements have been combined in order to extract the information about the accuracy of the mechanism movements as well as their repeatability under adverse environmental conditions.

  6. Long-range position and orientation tracking system

    International Nuclear Information System (INIS)

    Armstrong, G.A.; Jansen, J.F.; Burks, B.L.

    1995-01-01

    The long-range position and orientation tracking system will consist of two measurement pods, a VME-based computer system, and a detector array. The system is used to measure the position and orientation of a target that may be attached to a robotic arm, teleoperated manipulator, or autonomous vehicle. The pods have been designed to be mounted in the manways of the domes of the Fernald K-65 waste silos. Each pod has two laser scanner subsystems as well as lights and camera systems. One of the laser scanners will be oriented to scan in the pan direction, the other in the tilt direction. As the lasers scan across the detector array, the angles of incidence with each detector are recorded. Combining measurements from each of the four lasers yields sufficient data for a closed-form solution of the transform describing the location and orientation of the content mobilization system (CMS). Redundant detectors will be placed on the CMS to accommodate occlusions, to provide improved measurement accuracy, and to determine the CMS orientation

  7. Global Positioning System: Political Support, Directions of Development, and Expectations

    Directory of Open Access Journals (Sweden)

    Krzysztof Czaplewski

    2015-06-01

    Full Text Available Over the last decade the Global Positioning System has become a global, multifunctional tool which provides services that are an integral part of U.S. national security as well as the security of other highly developed countries. Economic development, transport security as well as homeland security are important elements of the global economic infrastructure. In 2000 the United States acknowledged the growing significance of GPS for civilian users and stopped intentionally degrading accuracy for non-military signals that are known as “Selective Availability”. Since then, commercial applications of satellite systems have been proliferating even more rapidly, and therefore, their importance in everyday life has greatly increased. Currently, services that depend on information obtained from the Global Positioning System are the driving force behind economic growth, economic development and the improvement in life safety. This economic development would not be possible without the financial and political support of the US government to maintain the operation of the GPS system. Therefore it is important to have knowledge about the intentions of the US government how system GPS will be developed in the future. Decisions taken in the last 3 months are the subject of this article.

  8. Precise positional measurement system in transcranial magnetic stimulation

    International Nuclear Information System (INIS)

    Inoue, Tomonori; Mishima, Yukuo; Hiwaki, Osamu

    2006-01-01

    Transcranial magnetic stimulation (TMS) is a method for noninvasive stimulation of cerebral cortex, and it has contributed to clinical and basic researches of brain function. In order to estimate the accurate stimulating points of the cortex in TMS, precise measurement of the subject's head and the stimulating coil is necessary. In this study, we have developed the positioning TMS system with a three-dimensional (3-D) digitizer and a multi-articular system. We proposed a method for the accurate measurement of a subject's head and cortex, in which the location data of the subject's face surface captured by a 3-D digitizer were superimposed on the magnetic resonance imaging (MRI) data of the subject's face surface. Using this system, the precise estimation of the stimulated sites of the cortex in TMS was achieved. The validity of the system was verified by the experiment on the TMS of the motor cortex. (author)

  9. An indoor positioning technology in the BLE mobile payment system

    Science.gov (United States)

    Han, Tiantian; Ding, Lei

    2017-05-01

    Mobile payment system for large supermarkets, the core function is through the BLE low-power Bluetooth technology to achieve the amount of payment in the mobile payment system, can through an indoor positioning technology to achieve value-added services. The technology by collecting Bluetooth RSSI, the fingerprint database of sampling points corresponding is established. To get Bluetooth module RSSI by the AP. Then, to use k-Nearest Neighbor match the value of the fingerprint database. Thereby, to help businesses find customers through the mall location, combined settlement amount of the customer's purchase of goods, to analyze customer's behavior. When the system collect signal strength, the distribution of the sampling points of RSSI is analyzed and the value is filtered. The system, used in the laboratory is designed to demonstrate the feasibility.

  10. Weapon System Requirements: Detailed Systems Engineering Prior to Product Development Positions Programs for Success

    Science.gov (United States)

    2016-11-01

    modified, replaced, or sustained by consumers or different manufacturers in addition to the manufacturer that developed the system. It also allows...WEAPON SYSTEM REQUIREMENTS Detailed Systems Engineering Prior to Product Development Positions Programs for Success...Engineering Prior to Product Development Positions Programs for Success Why GAO Did This Study Cost and schedule growth in DOD major defense

  11. Behavior of the Position-Spread Tensor in Diatomic Systems.

    Science.gov (United States)

    Brea, Oriana; El Khatib, Muammar; Angeli, Celestino; Bendazzoli, Gian Luigi; Evangelisti, Stefano; Leininger, Thierry

    2013-12-10

    The behavior of the Position-Spread Tensor (Λ) in a series of light diatomic molecules (either neutral or negative ions) is investigated at a Full Configuration Interaction level. This tensor, which is the second moment cumulant of the total position operator, is invariant with respect to molecular translations, while its trace is also rotationally invariant. Moreover, the tensor is additive in the case of noninteracting subsystems and can be seen as an intrinsic property of a molecule. In the present work, it is shown that the longitudinal component of the tensor, Λ∥, which is small for internuclear distances close to the equilibrium, tends to grow if the bond is stretched. A maximum is reached in the region of the bond breaking, then Λ∥ decreases and converges toward the isolated-atom value. The degenerate transversal components, Λ⊥, on the other hand, usually have a monotonic growth toward the atomic value. The Position Spread is extremely sensitive to reorganization of the molecular wave function, and it becomes larger in the case of an increase of the electron mobility, as illustrated by the neutral-ionic avoided crossing in LiF. For these reasons, the Position Spread can be an extremely useful property that characterizes the nature of the wave function in a molecular system.

  12. Inertial Pocket Navigation System: Unaided 3D Positioning

    Directory of Open Access Journals (Sweden)

    Estefania Munoz Diaz

    2015-04-01

    Full Text Available Inertial navigation systems use dead-reckoning to estimate the pedestrian’s position. There are two types of pedestrian dead-reckoning, the strapdown algorithm and the step-and-heading approach. Unlike the strapdown algorithm, which consists of the double integration of the three orthogonal accelerometer readings, the step-and-heading approach lacks the vertical displacement estimation. We propose the first step-and-heading approach based on unaided inertial data solving 3D positioning. We present a step detector for steps up and down and a novel vertical displacement estimator. Our navigation system uses the sensor introduced in the front pocket of the trousers, a likely location of a smartphone. The proposed algorithms are based on the opening angle of the leg or pitch angle. We analyzed our step detector and compared it with the state-of-the-art, as well as our already proposed step length estimator. Lastly, we assessed our vertical displacement estimator in a real-world scenario. We found that our algorithms outperform the literature step and heading algorithms and solve 3D positioning using unaided inertial data. Additionally, we found that with the pitch angle, five activities are distinguishable: standing, sitting, walking, walking up stairs and walking down stairs. This information complements the pedestrian location and is of interest for applications, such as elderly care.

  13. Inertial Pocket Navigation System: Unaided 3D Positioning

    Science.gov (United States)

    Munoz Diaz, Estefania

    2015-01-01

    Inertial navigation systems use dead-reckoning to estimate the pedestrian's position. There are two types of pedestrian dead-reckoning, the strapdown algorithm and the step-and-heading approach. Unlike the strapdown algorithm, which consists of the double integration of the three orthogonal accelerometer readings, the step-and-heading approach lacks the vertical displacement estimation. We propose the first step-and-heading approach based on unaided inertial data solving 3D positioning. We present a step detector for steps up and down and a novel vertical displacement estimator. Our navigation system uses the sensor introduced in the front pocket of the trousers, a likely location of a smartphone. The proposed algorithms are based on the opening angle of the leg or pitch angle. We analyzed our step detector and compared it with the state-of-the-art, as well as our already proposed step length estimator. Lastly, we assessed our vertical displacement estimator in a real-world scenario. We found that our algorithms outperform the literature step and heading algorithms and solve 3D positioning using unaided inertial data. Additionally, we found that with the pitch angle, five activities are distinguishable: standing, sitting, walking, walking up stairs and walking down stairs. This information complements the pedestrian location and is of interest for applications, such as elderly care. PMID:25897501

  14. ABOUT COMPLEX OPERATIONS IN NON-POSITIONAL RESIDUE NUMBER SYSTEM

    Directory of Open Access Journals (Sweden)

    Yu. D. Polissky

    2016-04-01

    Full Text Available Purpose. The purpose of this work is the theoretical substantiation of methods for increased efficiency of execution of difficult, so-called not modular, operations in non-positional residue number system for which it is necessary to know operand digits for all grade levels. Methodology. To achieve the target the numbers are presented in odd module system, while the result of the operation is determined on the basis of establishing the operand parity. The parity is determined by finding the sum modulo for the values of the number positional characteristics for all of its modules. Algorithm of position characteristics includes two types of iteration. The first iteration is to move from this number to a smaller number, in which the remains of one or more modules are equal to zero. This is achieved by subtracting out of all the residues the value of one of them. The second iteration is to move from this number to a smaller number due to exclusion of modules, which residues are zero, by dividing this number by the product of these modules. Iterations are performed until the residues of one, some or all of the modules equal to zero and other modules are excluded. The proposed method is distinguished by its simplicity and allows you to obtain the result of the operation quickly. Findings. There are obtained rather simple solutions of not modular operations for definition of outputs beyond the range of the result of adding or subtracting pairs of numbers, comparing pairs of numbers, determining the number belonging to the specific half of the range, defining parity of numbers presented in non-positional residue number system. Originality. The work offered the new effective approaches to solve the non-modular operations of the non-positional residue number system. It seems appropriate to consider these approaches as research areas to enhance the effectiveness of the modular calculation. Practical value. The above solutions have high performance and can

  15. Beam position measurement system at the Fermilab main accelerator

    International Nuclear Information System (INIS)

    Kerns, Q.A.

    1975-01-01

    The beam position system of the Fermilab Main Ring contains one horizontal and one vertical Electrostatic Beam Pickup in each of the 96 cells of the machine. A pair of 75 ohm cables transmits the induced signal from the machine tunnel to the nearest service building. In each of the 24 service buildings, there is a solid-state multiplexer and a beam position detector which processes the A-B signal pairs to produce an intensity-normalized voltage proportional to beam displacement. This voltage is digitized, read into buffer of the Lockheed MAC A, and in turn transferred to the Xerox 530. Horizontal or vertical orbits can be obtained in 50 millisec. Orbits are obtained at injection and at a Main Ring Sample time, if requested, anywhere on the acceleration cycle. Injection orbits can be flattened automatically by a program that sets dipole trim magnets. (auth)

  16. Positioning navigation and timing service applications in cyber physical systems

    Science.gov (United States)

    Qu, Yi; Wu, Xiaojing; Zeng, Lingchuan

    2017-10-01

    The positioning navigation and timing (PNT) architecture was discussed in detail, whose history, evolvement, current status and future plan were presented, main technologies were listed, advantages and limitations of most technologies were compared, novel approaches were introduced, and future capacities were sketched. The concept of cyber-physical system (CPS) was described and their primary features were interpreted. Then the three-layer architecture of CPS was illustrated. Next CPS requirements on PNT services were analyzed, including requirements on position reference and time reference, requirements on temporal-spatial error monitor, requirements on dynamic services, real-time services, autonomous services, security services and standard services. Finally challenges faced by PNT applications in CPS were concluded. The conclusion was expected to facilitate PNT applications in CPS, and furthermore to provide references to the design and implementation of both architectures.

  17. Atmospheric pressure loading effects on Global Positioning System coordinate determinations

    Science.gov (United States)

    Vandam, Tonie M.; Blewitt, Geoffrey; Heflin, Michael B.

    1994-01-01

    Earth deformation signals caused by atmospheric pressure loading are detected in vertical position estimates at Global Positioning System (GPS) stations. Surface displacements due to changes in atmospheric pressure account for up to 24% of the total variance in the GPS height estimates. The detected loading signals are larger at higher latitudes where pressure variations are greatest; the largest effect is observed at Fairbanks, Alaska (latitude 65 deg), with a signal root mean square (RMS) of 5 mm. Out of 19 continuously operating GPS sites (with a mean of 281 daily solutions per site), 18 show a positive correlation between the GPS vertical estimates and the modeled loading displacements. Accounting for loading reduces the variance of the vertical station positions on 12 of the 19 sites investigated. Removing the modeled pressure loading from GPS determinations of baseline length for baselines longer than 6000 km reduces the variance on 73 of the 117 baselines investigated. The slight increase in variance for some of the sites and baselines is consistent with expected statistical fluctuations. The results from most stations are consistent with approximately 65% of the modeled pressure load being found in the GPS vertical position measurements. Removing an annual signal from both the measured heights and the modeled load time series leaves this value unchanged. The source of the remaining discrepancy between the modeled and observed loading signal may be the result of (1) anisotropic effects in the Earth's loading response, (2) errors in GPS estimates of tropospheric delay, (3) errors in the surface pressure data, or (4) annual signals in the time series of loading and station heights. In addition, we find that using site dependent coefficients, determined by fitting local pressure to the modeled radial displacements, reduces the variance of the measured station heights as well as or better than using the global convolution sum.

  18. 77 FR 37430 - BSEE Information Collection Activity: Global Positioning System for MODUs, Extension of a...

    Science.gov (United States)

    2012-06-21

    ... major weather event, like a hurricane, lessees and operators need to report new GPS information to BSEE...-0012; OMB Control Number 1014-0013] BSEE Information Collection Activity: Global Positioning System for... Paperwork Reduction Act of 1995 (PRA), BSEE is inviting comments on a collection of information pertaining...

  19. Novel electro-hydraulic position control system for primary mirror supporting system

    Directory of Open Access Journals (Sweden)

    Xiongbin Peng

    2016-05-01

    Full Text Available In the field of modern large-scale telescope, primary mirror supporting system technology faces the difficulties of theoretically uniform output force request and bias compensation. Therefore, a novel position control system combining hydraulic system with servo motor system is introduced. The novel system ensures uniform output force on supporting points without complicating the mechanical structure. The structures of both primary mirror supporting system and novel position system are described. Then, the mathematical model of novel position control system is derived for controller selection. A proportional–derivative controller is adopted for simulations and experiments of step response and triangle path tracking. The results show that proportional–derivative controller guarantees the system with micrometer-level positioning ability. A modified proportional–derivative controller is utilized to promote system behavior with faster response overshoot. The novel position control system is then applied on primary mirror supporting system. Coupling effect is observed among actuator partitions, and relocation of virtual pivot supporting point is chosen as the decoupling measurement. The position keeping ability of the primary mirror supporting system is verified by rotating the mirror cell at a considerably high rate. The experiment results show that the decoupled system performs better with smaller bias and shorter recovery time.

  20. Workshop Builds Strategies to Address Global Positioning System Vulnerabilities

    Science.gov (United States)

    Fisher, Genene

    2011-01-01

    When we examine the impacts of space weather on society, do we really understand the risks? Can past experiences reliably predict what will happen in the future? As the complexity of technology increases, there is the potential for it to become more fragile, allowing for a single point of failure to bring down the entire system. Take the Global Positioning System (GPS) as an example. GPS positioning, navigation, and timing have become an integral part of daily life, supporting transportation and communications systems vital to the aviation, merchant marine, cargo, cellular phone, surveying, and oil exploration industries. Everyday activities such as banking, mobile phone operations, and even the control of power grids are facilitated by the accurate timing provided by GPS. Understanding the risks of space weather to GPS and the many economic sectors reliant upon it, as well as how to build resilience, was the focus of a policy workshop organized by the American Meteorological Society (AMS) and held on 13-14 October 2010 in Washington, D. C. The workshop brought together a select group of policy makers, space weather scientists, and GPS experts and users.

  1. The global positioning system and ArcGIS

    CERN Document Server

    Kennedy, Michael

    2009-01-01

    Foreword to the First EditionForeword to the Second EditionPreface for the Instructor, Third EditionAcknowledgmentsAbout the AuthorIntroductionChapter 1: Basic Concepts OverviewWhere Are You?What Time Is It?GPS and GISAnatomy of the Term ""Global Positioning System""How We Know Where Something IsStep-by-StepDisclaimerFirst OffDifferent Receivers and Different SoftwarePreparationProject 1AUnderstanding the Screens and ControlsProject 1BProject 1CChapter 2: Automated Data CollectionOverviewHow'd They Do That?How It Works: Measuring Distance by Measuring TimeFactors Affecting When and How to Coll

  2. Local Geoid Determination Using the Global Positioning System

    Science.gov (United States)

    1988-09-01

    Positioning System by Ma, Wei-Ming September 1988 Co-Advisor: Kandiah Jeyapalan Co-Advisor: Stevens P. Tucker Approved for public release; distribution is... Jeyapalan and Stevens P. Tucker, my thesis advisors, for their dedicated assistance and guidance during the study. Without their encouragement...method of collocation is [ Jeyapalan , 1977]: x = A*X+S +n +O.S q q P where x the vector of the observation (x = Ah - N0(X,Y,Z) - H) A a given rectangular

  3. A patient positioning system in head and neck irradiation

    International Nuclear Information System (INIS)

    Bormann, U.; Strauch, B.; Schmitt, G.

    1986-01-01

    A holding system is presented which allows a good, easy, and reproducable positioning of the patient in percutanous head and neck radiotherapy. The patients are lying comfortably on a neck support and are fixed in such a way that they are not able to turn in a lateral or longitudinal direction. The distance chin-jugulum can be easily determined by an integrated measuring tape. Due to the use of UV ink and UV lamps, the field marking of the patient's skin cannot be seen in the spectrum of visible light. (orig.) [de

  4. Sustaining Air Force Space Systems: A Model for the Global Positioning System

    National Research Council Canada - National Science Library

    Snyder, Don; Mills, Patrick; Comanor, Katherine; Roll, Jr, Charles R

    2007-01-01

    ... and sustainment affect the performance of space systems. In this monograph, we develop a pilot framework for analyzing these and related questions in the ground segment of the Global Positioning System and recommend steps for implementing this framework...

  5. Response of Autonomic Nervous System to Body Positions:

    Science.gov (United States)

    Xu, Aiguo; Gonnella, G.; Federici, A.; Stramaglia, S.; Simone, F.; Zenzola, A.; Santostasi, R.

    Two mathematical methods, the Fourier and wavelet transforms, were used to study the short term cardiovascular control system. Time series, picked from electrocardiogram and arterial blood pressure lasting 6 minutes, were analyzed in supine position (SUP), during the first (HD1) and the second parts (HD2) of 90° head down tilt, and during recovery (REC). The wavelet transform was performed using the Haar function of period T=2j (j=1,2,...,6) to obtain wavelet coefficients. Power spectra components were analyzed within three bands, VLF (0.003-0.04), LF (0.04-0.15) and HF (0.15-0.4) with the frequency unit cycle/interval. Wavelet transform demonstrated a higher discrimination among all analyzed periods than the Fourier transform. For the Fourier analysis, the LF of R-R intervals and VLF of systolic blood pressure show more evident difference for different body positions. For the wavelet analysis, the systolic blood pressures show much more evident differences than the R-R intervals. This study suggests a difference in the response of the vessels and the heart to different body positions. The partial dissociation between VLF and LF results is a physiologically relevant finding of this work.

  6. Significance of Waterway Navigation Positioning Systems On Ship's Manoeuvring Safety

    Science.gov (United States)

    Galor, W.

    The main goal of navigation is to lead the ship to the point of destination safety and efficiently. Various factors may affect ship realisating this process. The ship movement on waterway are mainly limited by water area dimensions (surface and depth). These limitations cause the requirement to realise the proper of ship movement trajectory. In case when this re requirement cant't fulfil then marine accident may happend. This fact is unwanted event caused losses of human health and life, damage or loss of cargo and ship, pollution of natural environment, damage of port structures or blocking the port of its ports and lost of salvage operation. These losses in same cases can be catas- trophical especially while e.i. crude oil spilling could be place. To realise of safety navigation process is needed to embrace the ship's movement trajectory by waterways area. The ship's trajectory is described by manoeuvring lane as a surface of water area which is require to realise of safety ship movement. Many conditions affect to ship manoeuvring line. The main are following: positioning accuracy, ship's manoeuvring features and phenomena's of shore and ship's bulk common affecting. The accuracy of positioning system is most important. This system depends on coast navigation mark- ing which can range many kinds of technical realisation. Mainly used systems based on lights (line), radionavigation (local system or GPS, DGPS), or radars. If accuracy of positiong is higer, then safety of navigation is growing. This article presents these problems exemplifying with approaching channel to ports situated on West Pomera- nian water region.

  7. The Human Eye Position Control System in a Rehabilitation Setting

    Directory of Open Access Journals (Sweden)

    Yvonne Nolan

    2005-01-01

    Full Text Available Our work at Ireland’s National Rehabilitation Hospital involves designing communication systems for people suffering from profound physical disabilities. One such system uses the electro-oculogram, which is an (x,y system of voltages picked up by pairs of electrodes placed, respectively, above and below and on either side of the eyes. The eyeball has a dc polarisation between cornea and back, arising from the photoreceptor rods and cones in the retina. As the eye rotates, the varying voltages projected onto the electrodes drive a cursor over a mimic keyboard on a computer screen. Symbols are selected with a switching action derived, for example, from a blink. Experience in using this mode of communication has given us limited facilities to study the eye position control system. We present here a resulting new feedback model for rotation in either the vertical or the horizontal plane, which involves the eyeball controlled by an agonist-antagonist muscle pair, modelled by a single equivalent bidirectional muscle with torque falling off linearly with angular velocity. We have incorporated muscle spindles and have tuned them by pole assignment associated with an optimum stability criterion.

  8. The projective geometry of the spacetime yielded by relativistic positioning systems and relativistic location systems

    OpenAIRE

    Rubin , Jacques ,

    2014-01-01

    Version de travail de thèse d'habilitation à diriger des recherches; Preprint; Current positioning systems are not primary, relativistic systems. Nevertheless, genuine, relativistic and primary positioning systems have been proposed recently by Bahder, Coll et al. and Rovelli to remedy such prior defects. These new designs all have in common an equivariant conformal geometry featuring, as the most basic ingredient, the spacetime geometry. We show how this conformal aspect can be the four-dime...

  9. Position-dependent mass, finite-gap systems, and supersymmetry

    Science.gov (United States)

    Bravo, Rafael; Plyushchay, Mikhail S.

    2016-05-01

    The ordering problem in quantum systems with position-dependent mass (PDM) is treated by inclusion of the classically fictitious similarity transformation into the kinetic term. This provides a generation of supersymmetry with the first-order supercharges from the kinetic term alone, while inclusion of the potential term allows us also to generate nonlinear supersymmetry with higher-order supercharges. A broad class of finite-gap systems with PDM is obtained by different reduction procedures, and general results on supersymmetry generation are applied to them. We show that elliptic finite-gap systems of Lamé and Darboux-Treibich-Verdier types can be obtained by reduction to Seiffert's spherical spiral and Bernoulli lemniscate in the presence of Calogero-like or harmonic oscillator potentials, or by angular momentum reduction of a free motion on some AdS2 -related surfaces in the presence of Aharonov-Bohm flux. The limiting cases include the Higgs and Mathews-Lakshmanan oscillator models as well as a reflectionless model with PDM exploited recently in the discussion of cosmological inflationary scenarios.

  10. Helicopter Approach Capability Using the Differential Global Positioning System

    Science.gov (United States)

    Kaufmann, David N.

    1994-01-01

    The results of flight tests to determine the feasibility of using the Global Positioning System (GPS) in the Differential mode (DGPS) to provide high accuracy, precision navigation and guidance for helicopter approaches to landing are presented. The airborne DGPS receiver and associated equipment is installed in a NASA UH-60 Black Hawk helicopter. The ground-based DGPS reference receiver is located at a surveyed test site and is equipped with a real-time VHF data link to transmit correction information to the airborne DGPS receiver. The corrected airborne DGPS information, together with the preset approach geometry, is used to calculate guidance commands which are sent to the aircraft's approach guidance instruments. The use of DGPS derived guidance for helicopter approaches to landing is evaluated by comparing the DGPS data with the laser tracker truth data. The errors indicate that the helicopter position based on DGPS guidance satisfies the International Civil Aviation Organization (ICAO) Category 1 (CAT 1) lateral and vertical navigational accuracy requirements.

  11. Practical Fingerprinting Localization for Indoor Positioning System by Using Beacons

    Directory of Open Access Journals (Sweden)

    Santosh Subedi

    2017-01-01

    Full Text Available Recent developments in the fields of smartphones and wireless communication technologies such as beacons, Wi-Fi, and ultra-wideband have made it possible to realize indoor positioning system (IPS with a few meters of accuracy. In this paper, an improvement over traditional fingerprinting localization is proposed by combining it with weighted centroid localization (WCL. The proposed localization method reduces the total number of fingerprint reference points over the localization space, thus minimizing both the time required for reading radio frequency signals and the number of reference points needed during the fingerprinting learning process, which eventually makes the process less time-consuming. The proposed positioning has two major steps of operation. In the first step, we have realized fingerprinting that utilizes lightly populated reference points (RPs and WCL individually. Using the location estimated at the first step, WCL is run again for the final location estimation. The proposed localization technique reduces the number of required fingerprint RPs by more than 40% compared to normal fingerprinting localization method with a similar localization estimation error.

  12. Volcano monitoring using the Global Positioning System: Filtering strategies

    Science.gov (United States)

    Larson, K.M.; Cervelli, Peter; Lisowski, M.; Miklius, Asta; Segall, P.; Owen, S.

    2001-01-01

    Permanent Global Positioning System (GPS) networks are routinely used for producing improved orbits and monitoring secular tectonic deformation. For these applications, data are transferred to an analysis center each day and routinely processed in 24-hour segments. To use GPS for monitoring volcanic events, which may last only a few hours, real-time or near real-time data processing and subdaily position estimates are valuable. Strategies have been researched for obtaining station coordinates every 15 min using a Kalman filter; these strategies have been tested on data collected by a GPS network on Kilauea Volcano. Data from this network are tracked continuously, recorded every 30 s, and telemetered hourly to the Hawaiian Volcano Observatory. A white noise model is heavily impacted by data outages and poor satellite geometry, but a properly constrained random walk model fits the data well. Using a borehole tiltmeter at Kilauea's summit as ground-truth, solutions using different random walk constraints were compared. This study indicates that signals on the order of 5 mm/h are resolvable using a random walk standard deviation of 0.45 cm/???h. Values lower than this suppress small signals, and values greater than this have significantly higher noise at periods of 1-6 hours. Copyright 2001 by the American Geophysical Union.

  13. Synthesis report: System studies Bioenergy

    International Nuclear Information System (INIS)

    Berntsson, Thore

    2003-01-01

    The present report marks the end of the research program 'System studies Bioenergy' (1998-2002). The program comprised 17 projects performed at 9 universities or research institutes. All project results were studied in order to identify: contributions to our present knowledge; possible gaps of knowledge, methodology or systems perspective that still exist; and the needs for further research. The projects can be classified into the following groups: Resource potential of forest fuels; Industrial use of biofuels; Potential for synthetic fuels (pellets, bio-oils and transportation fuels); System analysis of efficient use of biofuels; and Socio-economic analyses. The total potential for available biofuel has been estimated to be 125-175 TWh/year (excl. black liquors of paper industry). The potential demand is estimated to about 123 TWh/year, or distributed into the different sectors: Industry: 26 TWh/year, Buildings and services: 35 TWh/year, District heating: 31 TWh/year, and electric power generation (incl. cogeneration in district heating): 31 TWh/year. Further research is needed in the following areas: Systems and methodology of more generic character on optimization of production, refining and use of biofuels in order to substitute fossil fuels directly or indirectly; Heat sinks/district heating in combination with cogeneration vs. other power production in a long term perspective (> 10 years), in the light of new technologies, open markets, economic and political incentives; Energy efficiency in industry, esp. paper and pulp with its unique possibility for process integration, biofuel processing and CO 2 separation; How far should the processing/refinement of biofuels go; Importance of factors of scale; New distributed (small-scale) energy technology; International trade in biofuels; Transport and handling costs for biofuel pellets in Europe; System aspects of implementation and incentives; How are biofuels affected if CO 2 from fossil fuels can be separated and

  14. Low-cost Antenna Positioning System Designed with Axiomatic Design

    Directory of Open Access Journals (Sweden)

    Timothy Foley Joseph

    2017-01-01

    Full Text Available The Engineering Optimization and Modeling Center at Reykjavik University has been carrying out research on antenna CAD, including the simulation-driven design of novel antenna topologies. However, simulation is not enough to validate a design: a custom RF anechoic chamber has been built to quantify antenna performance, particularly in terms of field properties such as radiation patterns. Such experiments require careful positioning of the antenna in the chamber accurately in 3-axis with a short development time, challenging material constraints, and minimal funding. Axiomatic Design Theory principles were applied to develop an automated 3-axis positioner system for a reference antenna and the antenna to be calibrated. Each axis can be individually controlled with a repeatability of 1 degree. This 3000 USD device can be fabricated using easily available components and rapid prototyping tools.

  15. Incomplete factorization technique for positive definite linear systems

    International Nuclear Information System (INIS)

    Manteuffel, T.A.

    1980-01-01

    This paper describes a technique for solving the large sparse symmetric linear systems that arise from the application of finite element methods. The technique combines an incomplete factorization method called the shifted incomplete Cholesky factorization with the method of generalized conjugate gradients. The shifted incomplete Cholesky factorization produces a splitting of the matrix A that is dependent upon a parameter α. It is shown that if A is positive definite, then there is some α for which this splitting is possible and that this splitting is at least as good as the Jacobi splitting. The method is shown to be more efficient on a set of test problems than either direct methods or explicit iteration schemes

  16. Partial Sleep Deprivation Attenuates the Positive Affective System: Effects Across Multiple Measurement Modalities.

    Science.gov (United States)

    Finan, Patrick H; Quartana, Phillip J; Remeniuk, Bethany; Garland, Eric L; Rhudy, Jamie L; Hand, Matthew; Irwin, Michael R; Smith, Michael T

    2017-01-01

    Ample behavioral and neurobiological evidence links sleep and affective functioning. Recent self-report evidence suggests that the affective problems associated with sleep loss may be stronger for positive versus negative affective state and that those effects may be mediated by changes in electroencepholographically measured slow wave sleep (SWS). In the present study, we extend those preliminary findings using multiple measures of affective functioning. In a within-subject randomized crossover experiment, we tested the effects of one night of sleep continuity disruption via forced awakenings (FA) compared to one night of uninterrupted sleep (US) on three measures of positive and negative affective functioning: self-reported affective state, affective pain modulation, and affect-biased attention. The study was set in an inpatient clinical research suite. Healthy, good sleeping adults (N = 45) were included. Results indicated that a single night of sleep continuity disruption attenuated positive affective state via FA-induced reductions in SWS. Additionally, sleep continuity disruption attenuated the inhibition of pain by positive affect as well as attention bias to positive affective stimuli. Negative affective state, negative affective pain facilitation, nor negative attention bias were altered by sleep continuity disruption. The present findings, observed across multiple measures of affective function, suggest that sleep continuity disruption has a stronger influence on the positive affective system relative to the negative affective affective system. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  17. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  18. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  19. Mandatory Reporting of Child Abuse and Neglect: Crafting a Positive Process for Health Professionals and Caregivers

    Science.gov (United States)

    Pietrantonio, Anna Marie; Wright, Elise; Gibson, Kathleen N.; Alldred, Tracy; Jacobson, Dustin; Niec, Anne

    2013-01-01

    Health professionals working with children and their families are often required by law to report to governmental authorities any reasonable suspicion of child abuse and/or neglect. Extant research has pointed toward various barriers to reporting, with scant attention to positive processes to support the reporting process. This paper focuses on…

  20. Electro-Pneumatic Control System with Hydraulically Positioning Actuator Motor

    Directory of Open Access Journals (Sweden)

    V. N. Pilgunov

    2016-01-01

    Full Text Available A compressibility of the actuating fluid of a pneumatic drive (compressed air leads to significant landing of the pneumatic cylinder piston at the time of stop and hold of the load, a constant component of which can fluctuate significantly for the holding period.There are a lot of factors, which have a significant impact on the landing value of piston. Those are: an initial position of the piston at its stop, which determines the volume of the an active area of the piston, a value of the constant load component at the time of stop and its variation for the holding period, a transfer coefficient of the position component of the load, an active area of the pneumatic cylinder piston, as well as reduction in atmospheric pressure, which can significantly affect the operation of the control systems of small aircrafts flying at high altitudes.To reduce the landing value of piston due to changing value of the constant load component for its holding period, it is proposed to use a hydraulic positioner, which comprises a hydraulic cylinder the rod of which is rigidly connected to the rod of the pneumatic cylinder through the traverse, a cross-feed valve of the hydro-cylinder cavities with discrete electro-magnetic control, and adjustable chokes.A programmable logic controller provides the hydraulic positioner control. At the moment the piston stops and the load is held the cross-feed valve overlaps the hydro-cylinder cavities thereby locking the pneumatic cylinder piston and preventing its landing. With available pneumatic cylinder-controlled signal the cross-feed valve connects the piston and rod cavities of the positioner hydro-cylinder, the pneumatic cylinder piston is released and becomes capable of moving.A numerical estimate of landing of the pneumatic cylinder piston and its positioning quality is of essential interest. For this purpose, a technique to calculate the landing of piston has been developed taking into consideration that different

  1. Position of the European Union in the Global Trade System

    Directory of Open Access Journals (Sweden)

    Jovićević Mladen

    2017-12-01

    Full Text Available Only a few decades ago, the main drivers of globalization were the exchange of goods and capital flows, while the global trading system of today, fuelled by rapid technological changes increasingly bases itself on knowledge. The Key events - such as the use of the Internet and the increasingly important role of the rising countries economies - have contributed to a faster global exchange, but to a new nature as well. In order to illustrate the scope of the increase, perhaps it would be the best to mention the fact that in the 1970’s the share of trade in the world GDP amounted to 20%, whereas today it makes about one half. On the other hand, modern products represent compounds of raw materials, components, technologies and services originating from different areas and different continents, which has globalized the products themselves. In such conditions of the market competition, imposed by globalization and liberalization, for the European Union to remain as a leader, it had to prepare a sound and well-founded foreign policy strategy. The aim of this paper is to analyse the current position of the European Union in the global trading system, instruments of foreign trade policy, goals, foreign trade and the main challenges placed before the Union.

  2. X-ray beam-position feedback system with easy-to-use beam-position monitor.

    Science.gov (United States)

    Park, Jae Yeon; Kim, Yesul; Lee, Sangsul; Lim, Jun

    2018-05-01

    X-ray beam-position stability is indispensable in cutting-edge experiments using synchrotron radiation. Here, for the first time, a beam-position feedback system is presented that utilizes an easy-to-use X-ray beam-position monitor incorporating a diamond-fluorescence screen. The acceptable range of the monitor is above 500 µm and the feedback system maintains the beam position within 3 µm. In addition to being inexpensive, the system has two key advantages: it works without a scale factor for position calibration, and it has no dependence on X-ray energy, X-ray intensity, beam size or beam shape.

  3. Performance of a video-image-subtraction-based patient positioning system

    International Nuclear Information System (INIS)

    Milliken, Barrett D.; Rubin, Steven J.; Hamilton, Russell J.; Johnson, L. Scott; Chen, George T.Y.

    1997-01-01

    Purpose: We have developed and tested an interactive video system that utilizes image subtraction techniques to enable high precision patient repositioning using surface features. We report quantitative measurements of system performance characteristics. Methods and Materials: Video images can provide a high precision, low cost measure of patient position. Image subtraction techniques enable one to incorporate detailed information contained in the image of a carefully verified reference position into real-time images. We have developed a system using video cameras providing orthogonal images of the treatment setup. The images are acquired, processed and viewed using an inexpensive frame grabber and a PC. The subtraction images provide the interactive guidance needed to quickly and accurately place a patient in the same position for each treatment session. We describe the design and implementation of our system, and its quantitative performance, using images both to measure changes in position, and to achieve accurate setup reproducibility. Results: Under clinical conditions (60 cm field of view, 3.6 m object distance), the position of static, high contrast objects could be measured with a resolution of 0.04 mm (rms) in each of two dimensions. The two-dimensional position could be reproduced using the real-time image display with a resolution of 0.15 mm (rms). Two-dimensional measurement resolution of the head of a patient undergoing treatment for head and neck cancer was 0.1 mm (rms), using a lateral view, measuring the variation in position of the nose and the ear over the course of a single radiation treatment. Three-dimensional repositioning accuracy of the head of a healthy volunteer using orthogonal camera views was less than 0.7 mm (systematic error) with an rms variation of 1.2 mm. Setup adjustments based on the video images were typically performed within a few minutes. The higher precision achieved using the system to measure objects than to reposition

  4. Detention and positioning system for patient Treatment with conventional radiotherapy

    International Nuclear Information System (INIS)

    Hueso Bernad, Nuria; Tirado Porcar, Miriam; Del Castillo Arres, M. Jose; Broseta Tormos, M. Mercedes; Franch Martinez, Silvia; Suarez Dieguez, Raquel; Roures Ramos, M.Teresa

    2009-01-01

    The first step in what we call in radiotherapy S imulation and Planning o f radiation, is the correct choice of patient position and methods to use for this position is maintained along both the simulation and planning as the radiation treatment. The choice of position is directly linked to the choice of immobilizer to be used. (Author)

  5. Predicting Positive Education Outcomes for Emerging Adults in Mental Health Systems of Care.

    Science.gov (United States)

    Brennan, Eileen M; Nygren, Peggy; Stephens, Robert L; Croskey, Adrienne

    2016-10-01

    Emerging adults who receive services based on positive youth development models have shown an ability to shape their own life course to achieve positive goals. This paper reports secondary data analysis from the Longitudinal Child and Family Outcome Study including 248 culturally diverse youth ages 17 through 22 receiving mental health services in systems of care. After 12 months of services, school performance was positively related to youth ratings of school functioning and service participation and satisfaction. Regression analysis revealed ratings of young peoples' perceptions of school functioning, and their experience in services added to the significant prediction of satisfactory school performance, even controlling for sex and attendance. Finally, in addition to expected predictors, participation in planning their own services significantly predicted enrollment in higher education for those who finished high school. Findings suggest that programs and practices based on positive youth development approaches can improve educational outcomes for emerging adults.

  6. [A case of anti-LKM 1 positive autoimmune hepatitis accompanied by systemic lupus erythematosus].

    Science.gov (United States)

    Choi, Dae Han; Kim, Hae Kyung; Park, Tae Il; John, Byung Min; Kang, Sung Hwan; Lee, Yoon Serk; Kim, Tae Hyun; Lee, Uh Joo; Lee, Tae Seung; Yoon, Gwi Ok

    2008-03-01

    Overlap of autoimmune hepatitis and systemic lupus erythematosus (SLE) is a comparatively rare condition. Although both autoimmune hepatitis and SLE can share common autoimmune features such as polyarthralgia, hypergammaglobulinemia and positive ANA, it has been considered as two different entities. We report a case of anti-LKM1 positive autoimmune hepatitis who developed SLE two years later. The presence of interface hepatitis with lymphoplasma cell infiltrates and rosette formation points to the autoimmune hepatitis rather than SLE hepatitis. Autoimmune hepatitis is infrequently accompanied by SLE, therefore, it could be recommended to investigate for SLE in patients with autoimmune hepatitis.

  7. Systems analysis department annual progress report 1986

    International Nuclear Information System (INIS)

    Grohnheit, P.E.; Larsen, H.; Vestergaard, N.K.

    1987-02-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1986. The activities may be classified as energy systems analysis and risk and reliability analysis. The report includes a list of staff members. (author)

  8. National Fire Incident Reporting System (NFIRS)

    Data.gov (United States)

    Department of Homeland Security — The National Fire Incident Reporting System (NFIRS) is a reporting standard that fire departments use to uniformly report on the full range of their activities, from...

  9. Phosphoenolpyruvate phosphotransferase system components positively regulate Klebsiella biofilm formation

    Directory of Open Access Journals (Sweden)

    Yu-Tze Horng

    2018-04-01

    Full Text Available Background/Purpose: Klebsiella pneumoniae is one of the leading causes of device-related infections (DRIs, which are associated with attachment of bacteria to these devices to form a biofilm. The latter is composed of not only bacteria but also extracellular polymeric substances (EPSes consisting of extracellular DNAs, polysaccharides, and other macromolecules. The phosphoenolpyruvate (PEP:carbohydrate phosphotransferase system (PTS regulates diverse processes of bacterial physiology. In the genome of K. pneumoniae MGH 78578, we found an uncharacterized enzyme II complex homolog of PTS: KPN00353 (EIIA homolog, KPN00352 (EIIB homolog, and KPN00351 (EIIC homolog. The aim of this study was to characterize the potential physiological role of KPN00353, KPN00352, and KPN00351 in biofilm formation by K. pneumoniae. Methods/Results: We constructed the PTS mutants and recombinant strains carrying the gene(s of PTS. The recombinant K. pneumoniae strain overexpressing KPN00353–KPN00352–KPN00351 produced more extracellular matrix than did the vector control according to transmission and scanning electron microscopy. Judging by quantification of biofilm formation, of extracellular DNA (eDNA, and of capsular polysaccharide, the recombinant strain overexpressing KPN00353-KPN00352-KPN00351 produced more biofilm and capsular polysaccharide after overnight culture and more eDNA in the log phase as compared to the vector control. Conclusion: The genes, KPN00353–KPN00352–KPN00351, encode a putative enzyme II complex in PTS and positively regulate biofilm formation by enhancing production of eDNA and capsular polysaccharide in K. pneumoniae. Five proteins related to chaperones, to the citric acid cycle, and to quorum sensing are upregulated by the KPN00353–KPN00352–KPN00351 system. Keywords: Klebsiella, PTS, Biofilm, eDNA, Polysaccharide

  10. Building resilience of the Global Positioning System to space weather

    Science.gov (United States)

    Fisher, Genene; Kunches, Joseph

    2011-12-01

    Almost every aspect of the global economy now depends on GPS. Worldwide, nations are working to create a robust Global Navigation Satellite System (GNSS), which will provide global positioning, navigation, and timing (PNT) services for applications such as aviation, electric power distribution, financial exchange, maritime navigation, and emergency management. The U.S. government is examining the vulnerabilities of GPS, and it is well known that space weather events, such as geomagnetic storms, contribute to errors in single-frequency GPS and are a significant factor for differential GPS. The GPS industry has lately begun to recognize that total electron content (TEC) signal delays, ionospheric scintillation, and solar radio bursts can also interfere with daily operations and that these threats grow with the approach of the next solar maximum, expected to occur in 2013. The key challenges raised by these circumstances are, first, to better understand the vulnerability of GPS technologies and services to space weather and, second, to develop policies that will build resilience and mitigate risk.

  11. AKDNR - DNR Business Reporting System (DBRS)

    Science.gov (United States)

    Skip to content State of Alaska myAlaska My Government Resident Business in Alaska Visiting Alaska Resources > IRM GPU > Main Menu DNR Business Reporting System (DBRS) The DNR Business Reporting System (DBRS) allows users to generate reports from the DNR Business databases and maps. The reports offered

  12. A metrology system for a high resolution cavity beam position monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Walston, Sean, E-mail: walston2@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Boogert, Stewart [Royal Holloway, University of London, Egham (United Kingdom); Chung, Carl; Fitsos, Pete [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Frisch, Joe [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Gronberg, Jeff [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Hayano, Hitoshi [High Energy Accelerator Research Organization (KEK), Tsukuba-shi, Ibaraki-ken (Japan); Hinton, Shantell [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Honda, Yosuke [High Energy Accelerator Research Organization (KEK), Tsukuba-shi, Ibaraki-ken (Japan); Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter [University of California and Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Lyapin, Alexey; Malton, Stephen [University College London, London (United Kingdom); May, Justin; McCormick, Douglas [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Meller, Robert [Cornell University, Ithaca, NY (United States); Miller, David [University College London, London (United Kingdom); Orimoto, Toyoko [University of California and Lawrence Berkeley National Laboratory, Berkeley, CA (United States); California Institute of Technology, Pasadena, CA (United States); Ross, Marc [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Fermi National Accelerator Laboratory, Batavia, IL (United States); and others

    2013-11-11

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved–ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  13. A metrology system for a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Hinton, Shantell; Honda, Yosuke; Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2013-11-01

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved-ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  14. Airport Economics: Management Control Financial Reporting Systems

    Science.gov (United States)

    Buchbinder, A.

    1972-01-01

    The development of management control financial reporting systems for airport operation is discussed. The operation of the system to provide the reports required for determining the specific revenue producing facilities of airports is described. The organization of the cost reporting centers to show the types of information provided by the system is analyzed.

  15. Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.

    Science.gov (United States)

    Morrison, Aileen P; Tanasijevic, Milenko J; Goonan, Ellen M; Lobo, Margaret M; Bates, Michael M; Lipsitz, Stuart R; Bates, David W; Melanson, Stacy E F

    2010-06-01

    Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.

  16. Indolent Systemic Mastocytosis – a Case Report

    Directory of Open Access Journals (Sweden)

    Vujanović Ljuba

    2017-09-01

    Full Text Available Indolent systemic mastocytosis is a benign form of systemic mastocytosis characterized by an abnormal proliferation of mast cells either in the bone marrow or in numerous tissues. Case Report: A 27-year-old female patient was admitted to our department due to urticaria which started a month ago. Before the skin changes appeared, our patient suffered from a toothache, so she took various painkillers (nimesulide, ibuprofen, acetylsalicylic acid, paracetamol. During skin examination, individual hyperpigmented macules on the trunk and lower limbs were observed as incidental findings. The patient reported having them for the last two years. Darier's sign was positive. Following the examination, she was admitted due to suspected urticaria pigmentosa. Laboratory Findings: erythrocyte sedimentation rate: 9 mm/h; complete blood count, urine, blood glucose, total and direct bilirubin, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, urea, creatinine, and uric acid were within normal ranges. Electrolytes: sodium, potassium, chlorine clearance, total calcium and calcium ionized, osteocalcin, and crosslaps were within normal ranges as well. Fibrinogen: 5.57 g/l; 5-Hydroxyindoleacetic acid: 49.8 umol/dU (10.4 - 31.2. Bone densitometry, chest x-ray and upper abdomen ultrasound findings were normal. The suspected clinical diagnosis of urticaria pigmentosa was confirmed by skin biopsy. Histopathological examination of the bone marrow showed moderately increased cellularity (60 - 70%. All three types of blood cells were slightly multiplied. Focal infiltrations were found in the perivascular area, consisting of elongated, oval cells with abundant eosinophilic granular cytoplasm. The nuclei were regular, oval shaped with finely granular chromatin and inconspicuous nucleoli. No nuclear atypia was found. These cells are highly CD117-positive. This finding strongly indicated bone marrow infiltration in systemic mastocytosis. The

  17. Asystole following positive pressure insufflation of right pleural cavity: a case report

    Directory of Open Access Journals (Sweden)

    Konia Mojca R

    2011-06-01

    Full Text Available Abstract Introduction Adverse hemodynamic effects with severe bradycardia have been previously reported during positive pressure insufflation of the right thoracic cavity in humans. To the best of our knowledge, this is the first report of asystole during thoracoscopic surgery with positive pressure insufflation. Case presentation A 63-year-old Caucasian woman developed asystole at the onset of positive pressure insufflation of her right hemithorax during a thoracoscopic single-lung ventilation procedure. Immediate deflation of pleural cavity, intravenous glycopyrrolate and atropine administration returned her heart rhythm to normal sinus rhythm. The surgery proceeded in the absence of positive pressure insufflation without any further complications. Conclusions We discuss the proposed mechanisms of hemodynamic instability with positive pressure thoracic insufflation, and anesthetic and insufflation techniques that decrease the likelihood of adverse hemodynamic events.

  18. Performance of a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  19. Global Plate Velocities from the Global Positioning System

    Science.gov (United States)

    Larson, Kristine M.; Freymueller, Jeffrey T.; Philipsen, Steven

    1997-01-01

    We have analyzed 204 days of Global Positioning System (GPS) data from the global GPS network spanning January 1991 through March 1996. On the basis of these GPS coordinate solutions, we have estimated velocities for 38 sites, mostly located on the interiors of the Africa, Antarctica, Australia, Eurasia, Nazca, North America, Pacific, and South America plates. The uncertainties of the horizontal velocity components range from 1.2 to 5.0 mm/yr. With the exception of sites on the Pacific and Nazca plates, the GPS velocities agree with absolute plate model predictions within 95% confidence. For most of the sites in North America, Antarctica, and Eurasia, the agreement is better than 2 mm/yr. We find no persuasive evidence for significant vertical motions (less than 3 standard deviations), except at four sites. Three of these four were sites constrained to geodetic reference frame velocities. The GPS velocities were then used to estimate angular velocities for eight tectonic plates. Absolute angular velocities derived from the GPS data agree with the no net rotation (NNR) NUVEL-1A model within 95% confidence except for the Pacific plate. Our pole of rotation for the Pacific plate lies 11.5 deg west of the NNR NUVEL-1A pole, with an angular speed 10% faster. Our relative angular velocities agree with NUVEL-1A except for some involving the Pacific plate. While our Pacific-North America angular velocity differs significantly from NUVEL-1A, our model and NUVEL-1A predict very small differences in relative motion along the Pacific-North America plate boundary itself. Our Pacific-Australia and Pacific- Eurasia angular velocities are significantly faster than NUVEL-1A, predicting more rapid convergence at these two plate boundaries. Along the East Pacific Pise, our Pacific-Nazca angular velocity agrees in both rate and azimuth with NUVFL-1A.

  20. Tank waste remediation system mission analysis report

    International Nuclear Information System (INIS)

    Acree, C.D.

    1998-01-01

    The Tank Waste Remediation System Mission Analysis Report identifies the initial states of the system and the desired final states of the system. The Mission Analysis Report identifies target measures of success appropriate to program-level accomplishments. It also identifies program-level requirements and major system boundaries and interfaces

  1. A Short Tutorial on Inertial Navigation System and Global Positioning System Integration

    Science.gov (United States)

    Smalling, Kyle M.; Eure, Kenneth W.

    2015-01-01

    The purpose of this document is to describe a simple method of integrating Inertial Navigation System (INS) information with Global Positioning System (GPS) information for an improved estimate of vehicle attitude and position. A simple two dimensional (2D) case is considered. The attitude estimates are derived from sensor data and used in the estimation of vehicle position and velocity through dead reckoning within the INS. The INS estimates are updated with GPS estimates using a Kalman filter. This tutorial is intended for the novice user with a focus on bringing the reader from raw sensor measurements to an integrated position and attitude estimate. An application is given using a remotely controlled ground vehicle operating in assumed 2D environment. The theory is developed first followed by an illustrative example.

  2. Modular Systems Of Fixation And Position Jigs In The Production Process For Products And Systems

    Science.gov (United States)

    Babík, Ondrej; Šajgalík, Michal; Zaušková, Lucia; Czán, Andrej

    2015-12-01

    The project deals with design and implementation of adjustment onto mounting tables in the automotive industry. Manual control system of the jigs is replaced by a pneumatic system. Advantages of the pneumatic system are eliminating service side-time, improving work flow and increasing safety and ergonomics at work. Thanks to higher effectivity of the work process, manpower can be used in other work positions.

  3. The effects of positive emotion priming on self-reported reckless driving.

    Science.gov (United States)

    Taubman-Ben-Ari, Orit

    2012-03-01

    Five studies examined the effects of positive emotion priming on the willingness to drive recklessly. In all five, young drivers were exposed to one of the following primes of positive affect: a positive mood story; happy memories; an exciting film; a relaxing film; or thoughts on the meaning in life. Following the prime, the participants were asked to report on their willingness to drive recklessly. The responses were compared to those of groups exposed either to neutral affect, another kind of positive affect, or negative affect priming. In two of the studies, participants were also asked to report on their driving styles (risky, anxious, angry, or careful) as a second dependent variable. Positive affect, especially in the form of arousal, was found to be related to higher willingness to drive recklessly. Although men tended to report higher intentions to drive recklessly, men and women did not react differently to the emotional induction. Most interestingly, positive emotions of a relaxing nature, as well as thinking about the meaning in life, lowered the willingness to engage in risky driving. The discussion emphasizes the importance of looking for new ways to use positive emotions effectively in road safety interventions, and considers the practical implications of the studies. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Numerical studies of entangled positive-partial-transpose states in composite quantum systems

    International Nuclear Information System (INIS)

    Leinaas, Jon Magne; Sollid, Per Oyvind; Myrheim, Jan

    2010-01-01

    We report here on the results of numerical searches for PPT states in a series of bipartite quantum systems of low dimensions. PPT states are represented by density matrices that remain positive semidefinite under partial transposition with respect to one of the subsystems, and our searches are for such states with specified ranks for the density matrix and its partial transpose. For a series of different ranks extremal PPT states and nonextremal entangled PPT states have been found. The results are listed in tables and charted in diagrams. Comparison of the results for systems of different dimensions reveals several regularities. We discuss lower and upper bounds on the ranks of extremal PPT states.

  5. An online x-ray based position validation system for prostate hypofractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, Sankar, E-mail: Sankar.Arumugam@sswahs.nsw.gov.au; Xing, Aitang [Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, New South Wales 2170 (Australia); Sidhom, Mark [Department of Radiation Oncology, Liverpool and Macarthur Cancer Therapy Centres, New South Wales 2170 (Australia); Holloway, Lois [Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, New South Wales 2170 (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2522 (Australia); South Western Clinical School, University of New South Wales, Sydney, New South Wales 2052 (Australia); Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales 2006 (Australia)

    2016-02-15

    Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and

  6. Position indicating systems and reed contact unit assemblies for such systems

    International Nuclear Information System (INIS)

    Foxworthy, M.K.

    1980-01-01

    Specifications are given for a position indicating system for determining the position of a movable member inside a sealed container such as the position of a control rod in a nuclear reactor. The system comprises a magnetic flux producing member mounted to the movable member so as to move with it, a series of magnetic reed contact units mounted along the outside of the sealed container to be individually actuated by the flux producer as the movable member moves within the sealed container to indicate the position of this member. Each of the reed contact units is connected to a source of alternating electric current to produce a magnetic flux field to minimize the flux differential between the actuated and unactuated reed contact positions. A second aspect of the invention provides for a low operating flux differential reed contact unit assembly for a position indicating system such that it is actuated by the magnetic member at one magnetic flux level and deactivated at a second level. There is a source of alternating current connected to a coil surrounding the reed contact unit so as to produce an alternating magnetic flux with amplitude less than the difference between the two levels. Variations are given, also diagrams and benefits. (U.K.)

  7. Precise mean sea level measurements using the Global Positioning System

    Science.gov (United States)

    Kelecy, Thomas M.; Born, George H.; Parke, Michael E.; Rocken, Christian

    1994-01-01

    This paper describes the results of a sea level measurement test conducted off La Jolla, California, in November of 1991. The purpose of this test was to determine accurate sea level measurements using a Global Positioning System (GPS) equipped buoy. These measurements were intended to be used as the sea level component for calibration of the ERS 1 satellite altimeter. Measurements were collected on November 25 and 28 when the ERS 1 satellite overflew the calibration area. Two different types of buoys were used. A waverider design was used on November 25 and a spar design on November 28. This provided the opportunity to examine how dynamic effects of the measurement platform might affect the sea level accuracy. The two buoys were deployed at locations approximately 1.2 km apart and about 15 km west of a reference GPS receiver located on the rooftop of the Institute of Geophysics and Planetary Physics at the Scripps Institute of Oceanography. GPS solutions were computed for 45 minutes on each day and used to produce two sea level time series. An estimate of the mean sea level at both locations was computed by subtracting tide gage data collected at the Scripps Pier from the GPS-determined sea level measurements and then filtering out the high-frequency components due to waves and buoy dynamics. In both cases the GPS estimate differed from Rapp's mean altimetric surface by 0.06 m. Thus, the gradient in the GPS measurements matched the gradient in Rapp's surface. These results suggest that accurate sea level can be determined using GPS on widely differing platforms as long as care is taken to determine the height of the GPS antenna phase center above water level. Application areas include measurement of absolute sea level, of temporal variations in sea level, and of sea level gradients (dominantly the geoid). Specific applications would include ocean altimeter calibration, monitoring of sea level in remote regions, and regional experiments requiring spatial and

  8. Using satellite technology (global positioning system) to teach the spherical polar coordinate system

    International Nuclear Information System (INIS)

    O'Brien, William P Jr

    2003-01-01

    Students discover the equivalence between plausible geographic variables (co-latitude and longitude) of the Earth and less-familiar geometric variables (polar and azimuthal angles) of spherical polar coordinates by collecting and analysing positional data recorded during field exercises with a handheld global positioning system (GPS) receiver. This pedagogical approach to teaching spherical geometry, based on field experience rather than classroom theory, uses GPS technology to capture the curiosity of contemporary students, technical or otherwise, who might not normally find the topic of the spherical polar coordinate system comprehensible, relevant or interesting

  9. Northeast Electronic Reporting System (NERS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA/NEFSC Study fleets are a subset of fishing vessels from which high quality, self-reported data on fishing effort, area fished, gear characteristics, catch,...

  10. NONLINEAR DYNAMICAL SYSTEMS - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Philip Holmes

    2005-12-31

    This document is the final report on the work completed on DE-FG02-95ER25238 since the start of the second renewal period: Jan 1, 2001. It supplements the annual reports submitted in 2001 and 2002. In the renewal proposal I envisaged work in three main areas: Analytical and topological tools for studying flows and maps Low dimensional models of fluid flow Models of animal locomotion and I describe the progess made on each project.

  11. Critical Incident Reporting Systems: Perceived Competing Social ...

    African Journals Online (AJOL)

    The safe operation of complex socio-technical systems is dependent upon the reporting of safety critical incidents by operators within a system. Through the action of reporting, systems develop the capability as a learning organisation to improve human and organisational performance. The aim of the study is therefore to ...

  12. Could positive affect help engineer robot control systems?

    Science.gov (United States)

    Quirin, Markus; Hertzberg, Joachim; Kuhl, Julius; Stephan, Achim

    2011-11-01

    Emotions have long been seen as counteracting rational thought, but over the last decades, they have been viewed as adaptive processes to optimize human (but also animal) behaviour. In particular, positive affect appears to be a functional aspect of emotions closely related to that. We argue that positive affect as understood in Kuhl's PSI model of the human cognitive architecture appears to have an interpretation in state-of-the-art hybrid robot control architectures, which might help tackle some open questions in the field.

  13. Stability Tests of Positive Fractional Continuous-time Linear Systems with Delays

    Directory of Open Access Journals (Sweden)

    Tadeusz Kaczorek

    2013-06-01

    Full Text Available Necessary and sufficient conditions for the asymptotic stability of positive fractional continuous-time linear systems with many delays are established. It is shown that: 1 the asymptotic stability of the positive fractional system is independent of their delays, 2 the checking of the asymptotic stability of the positive fractional systems with delays can be reduced to checking of the asymptotic stability of positive standard linear systems without delays.

  14. Medicares Physician Quality Reporting System (PQRS)...

    Data.gov (United States)

    U.S. Department of Health & Human Services — Medicares Physician Quality Reporting System (PQRS) allows providers to report measures of process quality and health outcomes. The authors of Medicares Physician...

  15. CDC Wonder Vaccine Adverse Event Reporting System

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Vaccine Adverse Event Reporting System (VAERS) online database on CDC WONDER provides counts and percentages of adverse event case reports after vaccination,...

  16. Further support for association between GWAS variant for positive emotion and reward systems.

    Science.gov (United States)

    Lancaster, T M; Ihssen, N; Brindley, L M; Linden, D E J

    2017-01-31

    A recent genome-wide association study (GWAS) identified a significant single-nucleotide polymorphism (SNP) for trait-positive emotion at rs322931 on chromosome 1, which was also associated with brain activation in the reward system of healthy individuals when observing positive stimuli in a functional magnetic resonance imaging (fMRI) study. In the current study, we aimed to further validate the role of variation at rs322931 in reward processing. Using a similar fMRI approach, we use two paradigms that elicit a strong ventral striatum (VS) blood oxygen-level dependency (BOLD) response in a sample of young, healthy individuals (N=82). In the first study we use a similar picture-viewing task to the discovery sample (positive>neutral stimuli) to replicate an effect of the variant on emotion processing. In the second study we use a probabilistic reversal learning procedure to identify reward processing during decision-making under uncertainly (reward>punishment). In a region of interest (ROI) analysis of the bilateral VS, we show that the rs322931 genotype was associated with BOLD in the left VS during the positive>neutral contrast (P ROI-CORRECTED =0.045) and during the reward>punishment contrast (P ROI-CORRECTED =0.018), although the effect of passive picture viewing was in the opposite direction from that reported in the discovery sample. These findings suggest that the recently identified GWAS hit may influence positive emotion via individual differences in activity in the key hubs of the brain's reward system. Furthermore, these effects may not be limited to the passive viewing of positive emotional scenes, but may also be observed during dynamic decision-making. This study suggests that future studies of this GWAS locus may yield further insight into the biological mechanisms of psychopathologies characterised by deficits in reward processing and positive emotion.

  17. Positioning in Groups: A New Development in Systemic Consultation

    Science.gov (United States)

    Matthews, Jeff W.; Singh, RajVinder

    2015-01-01

    This article describes a new approach, employing a combination of Positioning Theory and Semantic Polarities, that educational psychologists can use to develop and facilitate change in organisations and groups. Resistance to change can be seen as reflecting a lack of the language that the members of an organisation need to participate effectively…

  18. 78 FR 13396 - 90th Meeting: RTCA Special Committee 159, Global Positioning Systems (GPS)

    Science.gov (United States)

    2013-02-27

    ... 159, Global Positioning Systems (GPS) AGENCY: Federal Aviation Administration (FAA), U.S. Department... 159, Global Positioning Systems (GPS) SUMMARY: The FAA is issuing this notice to advise the public of the eighty-ninth meeting of the RTCA Special Committee 159, Global Positioning Systems (GPS). DATES...

  19. 78 FR 57672 - 91st Meeting: RTCA Special Committee 159, Global Positioning Systems (GPS)

    Science.gov (United States)

    2013-09-19

    ... 159, Global Positioning Systems (GPS) AGENCY: Federal Aviation Administration (FAA), U.S. Department... 159, Global Positioning Systems (GPS). SUMMARY: The FAA is issuing this notice to advise the public of the ninety-first meeting of the RTCA Special Committee 159, Global Positioning Systems (GPS) DATES...

  20. 77 FR 12106 - 88th Meeting: RTCA Special Committee 159, Global Positioning System (GPS)

    Science.gov (United States)

    2012-02-28

    ... 159, Global Positioning System (GPS) AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION: Notice of RTCA Special Committee 159, Global Positioning System (GPS). SUMMARY: The..., Global Positioning System (GPS). DATES: The meeting will be held March 13-16, 2012, from 9 a.m.-4:30 p.m...

  1. 5 CFR 9701.231 - Conversion of positions and employees to the DHS classification system.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Conversion of positions and employees to... Provisions § 9701.231 Conversion of positions and employees to the DHS classification system. (a) This... from the GS system, a prevailing rate system, the SL/ST system, or the SES system, as provided in...

  2. Reporting of Positive Results in Randomized Controlled Trials of Mindfulness-Based Mental Health Interventions.

    Directory of Open Access Journals (Sweden)

    Stephanie Coronado-Montoya

    Full Text Available A large proportion of mindfulness-based therapy trials report statistically significant results, even in the context of very low statistical power. The objective of the present study was to characterize the reporting of "positive" results in randomized controlled trials of mindfulness-based therapy. We also assessed mindfulness-based therapy trial registrations for indications of possible reporting bias and reviewed recent systematic reviews and meta-analyses to determine whether reporting biases were identified.CINAHL, Cochrane CENTRAL, EMBASE, ISI, MEDLINE, PsycInfo, and SCOPUS databases were searched for randomized controlled trials of mindfulness-based therapy. The number of positive trials was described and compared to the number that might be expected if mindfulness-based therapy were similarly effective compared to individual therapy for depression. Trial registries were searched for mindfulness-based therapy registrations. CINAHL, Cochrane CENTRAL, EMBASE, ISI, MEDLINE, PsycInfo, and SCOPUS were also searched for mindfulness-based therapy systematic reviews and meta-analyses.108 (87% of 124 published trials reported ≥1 positive outcome in the abstract, and 109 (88% concluded that mindfulness-based therapy was effective, 1.6 times greater than the expected number of positive trials based on effect size d = 0.55 (expected number positive trials = 65.7. Of 21 trial registrations, 13 (62% remained unpublished 30 months post-trial completion. No trial registrations adequately specified a single primary outcome measure with time of assessment. None of 36 systematic reviews and meta-analyses concluded that effect estimates were overestimated due to reporting biases.The proportion of mindfulness-based therapy trials with statistically significant results may overstate what would occur in practice.

  3. Status report on the positive ion injector (PII) for ATLAS at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Zinkann, G.P.; Added, N.; Billquist, P.; Bogaty, J.; Clifft, B.; Markovich, P.; Phillips, D.; Strickhorn, P.; Shepard, K.W.

    1991-01-01

    The Positive Ion Injector (PII) is part of the Uranuim upgrade for ATLAS accelerator at Argonne National Laboratory. This paper will include a technical discussion of the Positive Ion Injector (PII) accelerator with its superconducting, niobium, very low-velocity accelerating structures. It will also discuss the current construction schedule of PII, and review an upgrade of the fast- tuning system. 10 refs., 6 figs

  4. Status report on the positive ion injector (PII) for ATLAS at Argonne National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Zinkann, G.P.; Added, N.; Billquist, P.; Bogaty, J.; Clifft, B.; Markovich, P.; Phillips, D.; Strickhorn, P.; Shepard, K.W.

    1991-01-01

    The Positive Ion Injector (PII) is part of the Uranuim upgrade for ATLAS accelerator at Argonne National Laboratory. This paper will include a technical discussion of the Positive Ion Injector (PII) accelerator with its superconducting, niobium, very low-velocity accelerating structures. It will also discuss the current construction schedule of PII, and review an upgrade of the fast- tuning system. 10 refs., 6 figs.

  5. The temporolimbic system theory of positive schizophrenic symptoms.

    Science.gov (United States)

    Bogerts, B

    1997-01-01

    This article proposes that subtle structural and functional disturbance of limbic key structures in the medial temporal lobe-especially of the left hippocampal formation and parahippocampal gyrus-can explain the so-called positive symptoms of schizophrenia. After presenting pathophysiological considerations linking limbic dysfunction to schizophrenia, the article reviews evidence from structural, biochemical, and functional studies supporting the theory. Also discussed here are neurodevelopmental and laterality aspects, as well as predictions, questions, and future tasks derived from the theory.

  6. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  7. Anti-glomerular basement membrane glomerulonephritis in an HIV positive patient: case report

    Directory of Open Access Journals (Sweden)

    Eduardo José Bellotto Monteiro

    Full Text Available We report on a case of a patient with HIV infection, diagnosed 18 months prior to the development of an anti-glomerular basement membrane (anti-GBM rapidly progressive glomerulonephritis; this is probably the first report of such an association. A 30-year-old white man presented with elevation of serum creatinine (1.3 - 13.5 mg/dL within one month. At admission, the urinalysis showed proteinuria of 7.2 g/L and 8,000,000 erythrocytes/mL. Renal biopsy corresponded to a crescentic diffuse proliferative glomerulonephritis mediated by anti-GBM, and serum testing for anti-GBM antibodies was positive; antinuclear antibodies (ANA and anti-neutrophilic cytoplasmic antibodies (ANCA were also positive. The patient underwent hemodyalisis and was treated with plasmapheresis, cyclophosphamide and prednisone. The association described here is not casual, as crescentic glomerulonephritis is not common in HIV-positive patients, anti-GBM glomerulonephritis is rare and anti-GBM antibodies are frequently observed in HIV-positive subjects when compared to the overall population. Based on the current case and on the elevated frequency of the positivity for such antibodies in this group of patients, it is advisable to be aware of the eventual association between these two conditions and to promote an active search for anti-GBM antibodies and early diagnosis of eventual urinary abnormalities in HIV-positive subjects, considering the severity of anti-GBM glomerulonephritis.

  8. 17 CFR Appendix B to Part 420 - Sample Large Position Report

    Science.gov (United States)

    2010-04-01

    ..., and as collateral for financial derivatives and other securities transactions $ Total Memorandum 1... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Sample Large Position Report B Appendix B to Part 420 Commodity and Securities Exchanges DEPARTMENT OF THE TREASURY REGULATIONS UNDER...

  9. Epidemiological comparisons of problems and positive qualities reported by adolescents in 24 countries

    DEFF Research Database (Denmark)

    Rescorla, Leslie; Achenbach, Thomas M; Ivanova, Masha Y

    2007-01-01

    In this study, the authors compared ratings of behavioral and emotional problems and positive qualities on the Youth Self-Report (T. M. Achenbach & L. A. Rescorla, 2001) by adolescents in general population samples from 24 countries (N = 27,206). For problem scales, country effect sizes (ESs) ran...

  10. Epidemiological Comparisons of Problems and Positive Qualities Reported by Adolescents in 24 Countries

    Science.gov (United States)

    Rescorla, Leslie; Achenbach, Thomas M.; Ivanova, Masha Y.; Dumenci, Levent; Almqvist, Fredrik; Bilenberg, Niels; Bird, Hector; Broberg, Anders; Dobrean, Anca; Dopfner, Manfred; Erol, Nese; Forns, Maria; Hannesdottir, Helga; Kanbayashi, Yasuko; Lambert, Michael C.; Leung, Patrick; Minaei, Asghar; Mulatu, Mesfin S.; Novik, Torunn S.; Oh, Kyung-Ja; Roussos, Alexandra; Sawyer, Michael; Simsek, Zeynep; Steinhausen, Hans-Christoph; Weintraub, Sheila; Metzke, Christa Winkler; Wolanczyk, Tomasz; Zilber, Nelly; Zukauskiene, Rita; Verhulst, Frank

    2007-01-01

    In this study, the authors compared ratings of behavioral and emotional problems and positive qualities on the Youth Self-Report (T. M. Achenbach & L. A. Rescorla, 2001) by adolescents in general population samples from 24 countries (N = 27,206). For problem scales, country effect sizes (ESs) ranged from 3% to 9%, whereas those for gender and age…

  11. A deterministic - approach controller design for electrohydraulic position servo control system

    International Nuclear Information System (INIS)

    Johari Osman

    2000-01-01

    This paper is concerned with the design of a tracking controller for controlling electrohydraulic position servo system based on a deterministic approach. The system is treated as an uncertain system with bounded uncertainties where the bounds are assumed known. It will be shown that the electrohydraulic position servo systems with the proposed controller is practically stable and tracks the desired position in spite of the uncertainties and nonlinearities present in the system (author)

  12. A modern automatic Carriage-Trolley Position Control System for Dhruva fuelling machine

    International Nuclear Information System (INIS)

    Agrawal, Ankit; Hari Balakrishna; Narvekar, J.P.; Sanadhya, Vivek

    2014-01-01

    A fully automatic absolute encoder based position control system has been designed developed implemented and commissioned for the Dhruva Fuelling Machine A (FM/A). This supports both the coarse and fine positioning modes. Provision for fully manual positioning as a standby system has been retained. This system replaces the ageing peg counting based incremental positioner used briefly during the early period after the Dhruva FM/A was commissioned. The older system suffered from peg detection skipping problems; hence it was not being used. Only full manual positioning was being carried out. This paper describes the automatic Carriage Trolley Position Control System (CTPCS). (author)

  13. Positive thinking about the future in newspaper reports and presidential addresses predicts economic downturn.

    Science.gov (United States)

    Sevincer, A Timur; Wagner, Greta; Kalvelage, Johanna; Oettingen, Gabriele

    2014-04-01

    Previous research has shown that positive thinking, in the form of fantasies about an idealized future, predicts low effort and poor performance. In the studies reported here, we used computerized content analysis of historical documents to investigate the relation between positive thinking about the future and economic development. During the financial crisis from 2007 to 2009, the more weekly newspaper articles in the economy page of USA Today contained positive thinking about the future, the more the Dow Jones Industrial Average declined in the subsequent week and 1 month later. In addition, between the New Deal era and the present time, the more presidential inaugural addresses contained positive thinking about the future, the more the gross domestic product and the employment rate declined in the presidents' subsequent tenures. These counterintuitive findings may help reveal the psychological processes that contribute to an economic crisis.

  14. Apollo experience report: Food systems

    Science.gov (United States)

    Smith, M. C., Jr.; Rapp, R. M.; Huber, C. S.; Rambaut, P. C.; Heidelbaugh, N. D.

    1974-01-01

    Development, delivery, and use of food systems in support of the Apollo 7 to 14 missions are discussed. Changes in design criteria for this unique program as mission requirements varied are traced from the baseline system that was established before the completion of the Gemini Program. Problems and progress in subsystem management, material selection, food packaging, development of new food items, menu design, and food-consumption methods under zero-gravity conditions are described. The effectiveness of various approaches in meeting food system objectives of providing flight crews with safe, nutritious, easy to prepare, and highly acceptable foods is considered. Nutritional quality and adequacy in maintaining crew health are discussed in relation to the establishment of nutritional criteria for future missions. Technological advances that have resulted from the design of separate food systems for the command module, the lunar module, The Mobile Quarantine Facility, and the Lunar Receiving Laboratory are presented for application to future manned spacecraft and to unique populations in earthbound situations.

  15. Preoperational test report, primary ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  16. Preoperational test report, primary ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  17. Preoperational test report, vent building ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  18. Plastic scintillators utilization in position sensitive detection systems

    International Nuclear Information System (INIS)

    Garcia, Marcelo Bernardes; Soares, Adalberto Jose; Baptista Filho, Benedito Dias

    2002-01-01

    This paper shows the viability of using a plastic scintillator detector to determine the one dimension position of a radioactive source. The experiments were performed using collimated 99m Tc sources of several activities supplied by the Centro de Radiofarmacia (from IPEN), and a 15 cm long plastic scintillator with diameter 5,08 cm, produced by the Centro de Tecnologia das Radiacoes (also from IPEN). The spectrum was obtained using the Genie 2000 software, and the results processed using a neural network specially developed for the proposed application. The final results demonstrate the viability of the proposed application. (author)

  19. Electro-Pneumatic Control System with Hydraulically Positioning Actuator Motor

    OpenAIRE

    V. N. Pilgunov; K. D. Efremova

    2016-01-01

    A compressibility of the actuating fluid of a pneumatic drive (compressed air) leads to significant landing of the pneumatic cylinder piston at the time of stop and hold of the load, a constant component of which can fluctuate significantly for the holding period.There are a lot of factors, which have a significant impact on the landing value of piston. Those are: an initial position of the piston at its stop, which determines the volume of the an active area of the piston, a value of the con...

  20. An Indoor Positioning System Based on Wearables for Ambient-Assisted Living.

    Science.gov (United States)

    Belmonte-Fernández, Óscar; Puertas-Cabedo, Adrian; Torres-Sospedra, Joaquín; Montoliu-Colás, Raúl; Trilles-Oliver, Sergi

    2016-12-25

    The urban population is growing at such a rate that by 2050 it is estimated that 84% of the world's population will live in cities, with flats being the most common living place. Moreover, WiFi technology is present in most developed country urban areas, with a quick growth in developing countries. New Ambient-Assisted Living applications will be developed in the near future having user positioning as ground technology: elderly tele-care, energy consumption, security and the like are strongly based on indoor positioning information. We present an Indoor Positioning System for wearable devices based on WiFi fingerprinting. Smart-watch wearable devices are used to acquire the WiFi strength signals of the surrounding Wireless Access Points used to build an ensemble of Machine Learning classification algorithms. Once built, the ensemble algorithm is used to locate a user based on the WiFi strength signals provided by the wearable device. Experimental results for five different urban flats are reported, showing that the system is robust and reliable enough for locating a user at room level into his/her home. Another interesting characteristic of the presented system is that it does not require deployment of any infrastructure, and it is unobtrusive, the only device required for it to work is a smart-watch.

  1. An Indoor Positioning System Based on Wearables for Ambient-Assisted Living

    Directory of Open Access Journals (Sweden)

    Óscar Belmonte-Fernández

    2016-12-01

    Full Text Available The urban population is growing at such a rate that by 2050 it is estimated that 84% of the world’s population will live in cities, with flats being the most common living place. Moreover, WiFi technology is present in most developed country urban areas, with a quick growth in developing countries. New Ambient-Assisted Living applications will be developed in the near future having user positioning as ground technology: elderly tele-care, energy consumption, security and the like are strongly based on indoor positioning information. We present an Indoor Positioning System for wearable devices based on WiFi fingerprinting. Smart-watch wearable devices are used to acquire the WiFi strength signals of the surrounding Wireless Access Points used to build an ensemble of Machine Learning classification algorithms. Once built, the ensemble algorithm is used to locate a user based on the WiFi strength signals provided by the wearable device. Experimental results for five different urban flats are reported, showing that the system is robust and reliable enough for locating a user at room level into his/her home. Another interesting characteristic of the presented system is that it does not require deployment of any infrastructure, and it is unobtrusive, the only device required for it to work is a smart-watch.

  2. Positive/negative magnetostrictive GMR trilayer systems as strain gauges

    International Nuclear Information System (INIS)

    Dokupil, S.; Bootsmann, M.-T.; Stein, S.; Loehndorf, M.; Quandt, E.

    2005-01-01

    Recently, highly sensitive strain gauges were developed, which are based on tunnel magnetoresistance (TMR) or giant magnetoresistance (GMR) effects combined with the inverse magnetostriction. GMR and TMR structures generally possess a symmetrical characteristic, which reflects the switching fields of the soft and hard layers, respectively. This characteristic can be changed by a stress field if the soft layer is replaced by a suitable magnetostrictive layer leading to a stress-induced rotation of the magnetostrictive layer with respect to the reference layer. Alternatively, both magnetic layers can be soft magnetic, one being positive and the other negative magnetostrictive. In this case, a stress applied on the stack leads to a reverse rotation of both layers due to the different sign in magnetostriction. This new approach is especially attractive since no reference layer is required which allows multilayering for GMR effect enhancement. This paper presents the stress biased characteristics of (FeCo/Cu/Ni) GMR trilayers in which the positive magnetostrictive FeCo and the negative magnetostrictive Ni replace the sensing and reference layer of a conventional GMR stack. The results can be interpreted by a simple model taking into account the magnetization direction of the individual layers and their response to mechanical strain in the range of 0.1-1%o

  3. Systemic assessment framework of a learning organization's competitive positioning

    Directory of Open Access Journals (Sweden)

    Wissam EL Hachem

    2014-09-01

    Full Text Available Purpose: The purpose of this paper is to devise an innovative feasible, replicable and comprehensive assessment framework of a learning organization's competitive positioning. Design/methodology/approach: The three characteristics listed above are approached as follows. Feasible refers to being easy and not in need of much resources (time, personnel,.... This is done through early elimination of non-important variables. Replicable is having a well structured methodology based on scientific proven methods. Following this methodology would result in good results that can be explained if needed and replicated if deemed necessary. Comprehensive translates into a holistic set of indices that measure performance as well as organizational learning. Findings and Originality/value: The three attributes (feasible, replicable and comprehensive have become crucial for ensuring any kind of added value for such a methodology that hopes to tackle the modern dynamic business environment and gaining a sustainable competitive advantage. Research limitations/implications: Such a methodology would require several full contextual applications to be able to set its final design. It entails thorough internal revision of a company's structure. Therefore a great deal of transparency and self-transcendence from the individual involved is a pre-requisite for any chance of success. Originality/value: It offers a systematic way to assess a company's performance/competitive positioning while accounting for the crucial attribute of organizational learning in its makeup.

  4. Case report 561: Systemic mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Schweitzer, M.E.; Irwin, G.A.L. (Nassau County Medical Center, East Meadow, NY (USA). Dept. of Radiology)

    1989-08-01

    A case is presented of a 55-year-old man with systemic mastocytosis. CT studies showed mesenteric and retroperetoneal lymphadenopathy, hepatosplenomegaly and sclerotic lesions of lumbar vertebrae. Lesions of the skin were absent. Pathological studies of lymph nodes indicated the presence of mastocytosis. The clinical, radiological and pathological features of this disorder and its five forms were discussed. Prognosis and treatment were also considered. (orig./GDG).

  5. Case report 369: Systemic mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodenberg, J.C.; Maegaard, K.K.; Svanholm, H.

    1986-05-01

    In summary, the case of a 58-year-old woman with upper gastrointestinal symptoms and a reddish-brown skin rash over a number of years has been presented. Biopsies from various sites, including bone marrow, were negative initially. A repeat cutaneous biopsy demonstrated the presence of systemic mastocytis. The characteristic clinical and radiological aspects of mastocytosis were described and the pathological features also were considered. A relevant differential diagnosis of the sclerotic form of mastocytosis was presented.

  6. Systems Analysis Department annual progress report 1998

    DEFF Research Database (Denmark)

    1999-01-01

    The report describes the work of the Systems Analysis Department at Risø National Laboratory during 1998. The department undertakes research within Energy Systems Analysis, Integrated Energy, Environment and Development Planning - UNEP Centre, IndustrialSafety and Reliability, Man/Machine Interac....../Machine Interaction, and Technology Scenarios. The report includes lists of publications, lectures, committees and staff members....

  7. Systems Analysis Department. Annual Report 2003

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, H.; Olsson, C. (eds.)

    2004-04-01

    This report describes the work of the Systems Analysis Department at Risoe National Laboratory during 2003. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning UNEP Centre, Safety, Reliability and Human Factors, and Technology Scenarios. The report includes summary statistics and list of staff members. (au)

  8. Systems Analysis Department. Annual Report 2001

    Energy Technology Data Exchange (ETDEWEB)

    Duijm, N J; Jensen, E; Larsen, H; Skipper, S [eds.

    2002-04-01

    This report describes the work of the Systems Analysis Department at Risoe National Laboratory during 2001. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning - UNEP Centre, Safety, Reliability and Human Factors, and Technology Scenarios. The report includes summary statistics and lists of publications, committees and staff members. (au)

  9. Systems Analysis Department annual report 2003

    DEFF Research Database (Denmark)

    2004-01-01

    This report describes the work of the Systems Analysis Department at Risø National Laboratory during 2003. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning – UNEP Centre, Safety,Reliability and Human Factors, and Technology...... Scenarios. The report includes summary statistics and list of staff members....

  10. Systems Analysis Department. Annual Progress Report 1999

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Hans; Olsson, Charlotte; Loevborg, Leif [eds.

    2000-03-01

    This report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1999. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning-UNEP Centre, Safety, Reliability and Human Factors, and Technology Scenarios. The report includes summary statistics and lists of publications, committees and staff members. (au)

  11. Systems Analysis department. Annual progress report 1997

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Hans; Olsson, Charlotte; Petersen, Kurt E

    1998-03-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1997. The department is undertaking research within Energy systems Analysis, Integrated Energy, Environment and Development Planning - UNEP Centre, Industrial Safety and Reliability and Man/Machine Interaction. The report includes lists of publications lectures, committees and staff members. (au) 110 refs.

  12. Systems Analysis Department. Annual progress report 1996

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, H; Olsson, C; Petersen, K E [eds.

    1997-03-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1996. The department is undertaking research within Simulation and Optimisation of Energy Systems, Energy and Environment in Developing Countries - UNEP Centre, Integrated Environmental and Risk Management and Man/Machine Interaction. The report includes lists of publications, lectures, committees and staff members. (au) 131 refs.

  13. Energy Systems Group. Annual Progress Report 1984

    DEFF Research Database (Denmark)

    Grohnheit, Poul Erik; Larsen, Hans Hvidtfeldt; Villadsen, B.

    The report describes the work of the Energy Systems Group at Risø National Laboratory during 1984. The activities may be roughly classified as development and use of energy-economy models, energy systems analysis, energy technology assessment and energy planning. The report includes a list of staff...

  14. System Analysis Department. Annual Report 2002

    Energy Technology Data Exchange (ETDEWEB)

    Duijm, N J; Jensen, E; Larsen, H; Skipper, S [eds.

    2002-04-01

    This report describes the work of the Systems Analysis Department at Risoe National Laboratory during 2001. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning - UNEP Centre, Safety, Reliability and Human Factors, and Technology Scenarios. The report includes summary statistics and lists of publications, committees and staff members. (au)

  15. Systems Analysis Department. Annual Report 2000

    Energy Technology Data Exchange (ETDEWEB)

    Duijm, N J; Jensen, E; Larsen, H; Olsson, C

    2001-05-01

    This report describes the work of the Systems Analysis Department at Risoe National Laboratory during 2000. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning - UNEP Centre, Safety, Reliability and Human Factors, and Technology Scenarios. The report includes summary statistics and lists of publications, committees and staff members. (au)

  16. Systems Analysis Department annual progress report 1998

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Hans; Olsson, Charlotte; Loevborg, Leif [eds.

    1999-03-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1998. The department undertakes research within Energy Systems Analysis, Integrated Energy, Environment and Development Planning - UNEP Centre, Industrial Safety and Reliability, Man/Machine Interaction and Technology Scenarios. The report includes lists of publications, lectures, committees and staff members. (au) 111 refs.

  17. Energy Systems Group annual progress report 1984

    International Nuclear Information System (INIS)

    Grohnheit, P.E.; Larsen, H.; Villadsen, B.

    1985-02-01

    The report describes the work of the Energy Systems Group at Risoe National Laboratory during 1984. The activities may be roughly classified as development and use of energy-economy models, energy systems analysis, energy technology assessment and energy planning. The report includes a list of staff members. (author)

  18. A Doppler Radar System for Sensing Physiological Parameters in Walking and Standing Positions

    Directory of Open Access Journals (Sweden)

    Malikeh Pour Ebrahim

    2017-03-01

    Full Text Available Doppler radar can be implemented for sensing physiological parameters wirelessly at a distance. Detecting respiration rate, an important human body parameter, is essential in a range of applications like emergency and military healthcare environments, and Doppler radar records actual chest motion. One challenge in using Doppler radar is being able to monitor several patients simultaneously and in different situations like standing, walking, or lying. This paper presents a complete transmitter-receiver Doppler radar system, which uses a 4 GHz continuous wave radar signal transmission and receiving system, to extract base-band data from a phase-shifted signal. This work reports experimental evaluations of the system for one and two subjects in various standing and walking positions. It provides a detailed signal analysis of various breathing rates of these two subjects simultaneously. These results will be useful in future medical monitoring applications.

  19. Self-reported oral and general health in relation to socioeconomic position.

    Science.gov (United States)

    Hakeberg, Magnus; Wide Boman, Ulla

    2017-07-26

    During the past two decades, several scientific publications from different countries have shown how oral health in the population varies with social determinants. The aim of the present study was to explore the relationship between self-reported oral and general health in relation to different measures of socioeconomic position. Data were collected from a randomly selected sample of the adult population in Sweden (n = 3500, mean age 53.4 years, 53.1% women). The response rate was 49.7%. Subjects were interviewed by telephone, using a questionnaire including items on self-reported oral and general health, socioeconomic position and lifestyle. A significant gradient was found for both oral and general health: the lower the socioeconomic position, the poorer the health. Socioeconomic position and, above all, economic measures were strongly associated with general health (OR 3.95) and with oral health (OR 1.76) if having an income below SEK 200,000 per year. Similar results were found in multivariate analyses controlling for age, gender and lifestyle variables. For adults, there are clear socioeconomic gradients in self-reported oral and general health, irrespective of different socioeconomic measures. Action is needed to ensure greater equity of oral and general health.

  20. Is position of solar system in the Galaxy anything exceptional

    International Nuclear Information System (INIS)

    Marochnik, L.

    1984-01-01

    The latest astrophysical knowledge shows that the solar system is in the vicinity of the so-called corotation circle. It rotates around the nucleus of the galaxy almost synchronously with the density wave, i.e., with the spiral structure, which has created specific conditions for the development of the pre-solar cloud from which has evolved our solar system. This development took place between the arms of the galaxy, i.e., in a relatively calm area which probably made possible the origin of life. (Ha)

  1. Method and apparatus for animal positioning in imaging systems

    Science.gov (United States)

    Hadjioannou, Arion-Xenofon; Stout, David B.; Silverman, Robert W.

    2013-01-01

    An apparatus for imaging an animal includes a first mounting surface, a bed sized to support the animal and releasably secured to or integral with the first mounting surface. The apparatus also includes a plurality of straps, each having a first end in a fixed position relative to the bed and a second end for tightening around a limb of the animal. A method for in-vivo imaging of an animal includes providing an animal that has limbs, providing a first mounting surface, and providing a bed removably secured to or integral with the mounting surface and sized to support the animal as well as being coupled to a plurality of straps. The method also includes placing the animal on the bed between the plurality of straps and tightening at least two of the plurality of straps around at least two of the limbs such that the animal is substantially secured in place relative to the bed.

  2. A state variable approach to the BESSY II local beam-position-feedback system

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Khan, S.; Kraemer, D.

    1996-01-01

    At the BESSY II facility, stability of the electron beam position and angle near insertion devices (IDs) is of utmost importance. Disturbances due to ground motion could result in unwanted broad-bandwidth beam-jitter which decreases the electron (and resultant photon) beam's effective brightness. Therefore, feedback techniques must be used. Operating over a frequency range of 100-Hz, a local feedback system will correct these beam-trajectory errors using the four bumps around IDs. This paper reviews how the state-variable feedback approach can be applied to real-time correction of these beam position and angle errors. A frequency-domain solution showing beam jitter reduction is presented. Finally, this paper reports results of a beam-feedback test at BESSY I

  3. Osteoarticular tuberculosis in an HIV-positive patient: a case report

    Directory of Open Access Journals (Sweden)

    Gabriela de Moraes Rêgo Guedes

    2014-06-01

    Full Text Available The authors report a case of a 38-year-old HIV-positive woman, with subcutaneous nodules on the thoracic region with 3 months of evolution. Clinical, laboratory, and epidemiological features were evaluated and associated with apparent damage to the T11-T12 vertebrae, identification by imaging tests, positivity in a polymerase chain reaction-based test, and reactivity to the Mantoux tuberculin skin test (PPD-RT 23. The patient was diagnosed with osteoarticular tuberculosis and received treatment for a year, and clinical cure was achieved.

  4. Insights into horizontal canal benign paroxysmal positional vertigo from a human case report.

    Science.gov (United States)

    Aron, Margaret; Bance, Manohar

    2013-12-01

    For horizontal canal benign paroxysmal positional vertigo, determination of the pathologic side is difficult and based on many physiological assumptions. This article reports findings on a patient who had one dysfunctional inner ear and who presented with horizontal canal benign paroxysmal positional vertigo, giving us a relatively pure model for observing nystagmus arising in a subject in whom the affected side is known a priori. It is an interesting human model corroborating theories of nystagmus generation in this pathology and also serves to validate Ewald's second law in a living human subject. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Benign lymphoepithelial cysts of the parotid glands in HIV-positive patients. A case report

    International Nuclear Information System (INIS)

    Piqueras, R.M.; Marco, S.F.; Lazaro, S.; Gonzlez, M.

    1997-01-01

    Benign parotid lymphoepithelial cysts (BPLEC) with cervical lymph node involvement are a recently reported radiological sign of HIV infection in head and neck in patients ar risk for developing AIDS. These cysts lesions present in the parotid glands of HIV-positive individuals and are associated with cervical lymph node involvement. We present a case of BPLEC in a HIV-positive patients that was studied by ultrasound and computerized tomography. The diagnosis was confirmed by ultrasound-guided percutaneous biopsy. We describe the radiological signs of this lesion as detected by the imaging techniques employed and we establish the differential diagnosis. (Author) 14 refs

  6. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  7. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  8. 78 FR 5767 - Positive Train Control Systems (RRR)

    Science.gov (United States)

    2013-01-28

    ..., modify the default procedures for handling the en route failure of PTC systems, and allow automatic... seeks information sufficient to make a reasoned determination that benefits justify costs and therefore... practicability of the waiver process as an acceptable method of handling such operations. In the Petition, AAR...

  9. Canister positioning. Influence of fracture system on deposition hole stability

    International Nuclear Information System (INIS)

    Hoekmark, Harald

    2003-11-01

    The study concerns the mechanical behaviour of rock surrounding tunnels and deposition holes in a nuclear waste repository. The mechanical effects of tunnel excavation and deposition hole excavation are investigated by use of a tunnel scale numerical model representing a part of a KBS-3 type repository. The excavation geometry, the initial pre-mining state of stress, and the geometrical features of the fracture system are defined according to conditions that prevail in the TBM tunnel rock mass in Aespoe HRL. Comparisons are made between results obtained without consideration of fractures and results obtained with inclusion of the fracture system. The focus is on the region around the intersection of a tunnel and a deposition hole. A general conclusion is that a fracture system of the type found in the TBM rock mass does not have a decisive influence on the stability of the deposition holes. To estimate the expected extent of spalling, information about other conditions, e.g. the orientation of the initial stresses and the strength properties of the intact rock, is more important than detailed information about the fracture system

  10. 77 FR 28285 - Positive Train Control Systems (RRR)

    Science.gov (United States)

    2012-05-14

    ... Privacy Act heading in the SUPPLEMENTARY INFORMATION section of this document for Privacy Act information.... Environmental Impact F. Unfunded Mandates Reform Act of 1995 G. Energy Impact H. Privacy Act I. Executive... possible. However, reducing the probability of future controversies over future installation of PTC systems...

  11. Medication incidents reported to an online incident reporting system.

    LENUS (Irish Health Repository)

    Alrwisan, Adel

    2011-01-15

    AIMS: Approximately 20% of deaths from adverse events are related to medication incidents, costing the NHS an additional £500 million annually. Less than 5% of adverse events are reported. This study aims to assess the reporting rate of medication incidents in NHS facilities in the north east of Scotland, and to describe the types and outcomes of reported incidents among different services. Furthermore, we wished to quantify the proportion of reported incidents according to the reporters\\' profession. METHODS: A retrospective description was made of medication incidents reported to an online reporting system (DATIX) over a 46-month-period (July 2005 to April 2009). Reports originated from acute and community hospitals, mental health, and primary care facilities. RESULTS: Over the study period there were 2,666 incidents reported with a mean monthly reporting rate of 78.2\\/month (SD±16.9). 6.1% of all incidents resulted in harm, with insulin being the most commonly implicated medication. Nearly three-quarters (74.2%, n=1,978) of total incidents originated from acute hospitals. Administration incidents were implicated in the majority of the reported medication incidents (59%), followed by prescribing (10.8%) and dispensing (9.9%), while the nondescript "other medication incidents" accounted for 20.3% of total incidents. The majority of reports were made by nursing and midwifery staff (80%), with medical and dental professionals reporting the lowest number of incidents (n=56, 2%). CONCLUSIONS: The majority of medication incidents in this study were reported by nursing and midwifery staff, and were due to administration incidents. There is a clear need to elucidate the reasons for the limited contribution of the medical and dental professionals to reporting medication incidents.

  12. NNWSI project information management system concepts evaluation report. Final report

    International Nuclear Information System (INIS)

    1986-08-01

    This report is intended as a first step in developing detailed information management system specifications for the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. The current state of information management at the NNWSI Project level is investigated and an information management system (IMS) is proposed. The IMS as it relates to aspects of Project and records management is discussed. Information management concepts and prospective IMS system components are investigated. Concepts and system components include: indexing, searching, retrieval, data base management system technology, computers, storage media, computer-assisted retrieval (CAR) of microfilm, electronic imaging-based systems, optical character recognition, and communications. Performance criteria and desirable system attributes applicable to the IMS are discussed. Six conceptual system approaches capable of satisfying the performance criteria are defined. System approaches include: fully centralized microfilm system based on CAR retrieval (Approach 1), partially distributed microfilm system based on CAR retrieval (Approach 2), fully distributed microfilm system based on CAR retrieval (Approach 3), fully centralized optical disk system based on electronic image and full-text retrieval (Approach 4), partially distributed optical system based on electron image and full-text retrieval (Approach 5), and fully distributed optical disk system based on electronic image and full-text retrieval (Approach 6). Technical and cost considerations associated with the six conceptual approaches are evaluated. Technical evaluation results indicate Approach 4 is the best conceptual approach, and cost evaluation results show no significant differences among approaches. On the basis of the evaluation, Approach 4 is recommended

  13. Pamela tracking system status report

    CERN Document Server

    Taccetti, F; Bonechi, L; Bongi, M; Boscherini, M; Castellini, G; D'Alessandro, R; Gabbanini, A; Grandi, M; Papini, P; Piccardi, S; Ricciarini, S; Spillantini, P; Straulino, S; Tesi, M; Vannuccini, E

    2002-01-01

    The Pamela apparatus will be launched at the end of 2002 on board of the Resurs DK Russian satellite. The tracking system, composed of six planes of silicon sensors inserted inside a permanent magnetic field was intensively tested during these last years. Results of tests have shown a good signal-to-noise ratio and an excellent spatial resolution, which should allow to measure the antiproton flux in an energy range from 80 MeV up to 190 GeV. The production of the final detector modules is about to start and mechanical and thermal tests on the tracking tower are being performed according to the specifications of the Russian launcher and satellite.

  14. Brief Report: Assessing Attitudes toward Culturally and Contextually Relevant Schoolwide Positive Behavior Support Strategies

    Science.gov (United States)

    Fallon, Lindsay M.; O'Keeffe, Breda V.; Gage, Nicholas A.; Sugai, George

    2015-01-01

    Given the increased interest and implementation of Schoolwide Positive Behavior Support (SWPBS) systems in schools in the United States, practitioners and researchers have become interested in how to improve implementation with students and staff from a wide range of cultural backgrounds. Fallon, O'Keeffe, and Sugai (2012) reviewed the literature…

  15. Error Analysis System for Spacecraft Navigation Using the Global Positioning System (GPS)

    Science.gov (United States)

    Truong, S. H.; Hart, R. C.; Hartman, K. R.; Tomcsik, T. L.; Searl, J. E.; Bernstein, A.

    1997-01-01

    The Flight Dynamics Division (FDD) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) is currently developing improved space-navigation filtering algorithms to use the Global Positioning System (GPS) for autonomous real-time onboard orbit determination. In connection with a GPS technology demonstration on the Small Satellite Technology Initiative (SSTI)/Lewis spacecraft, FDD analysts and programmers have teamed with the GSFC Guidance, Navigation, and Control Branch to develop the GPS Enhanced Orbit Determination Experiment (GEODE) system. The GEODE system consists of a Kalman filter operating as a navigation tool for estimating the position, velocity, and additional states required to accurately navigate the orbiting Lewis spacecraft by using astrodynamic modeling and GPS measurements from the receiver. A parallel effort at the FDD is the development of a GPS Error Analysis System (GEAS) that will be used to analyze and improve navigation filtering algorithms during development phases and during in-flight calibration. For GEAS, the Kalman filter theory is extended to estimate the errors in position, velocity, and other error states of interest. The estimation of errors in physical variables at regular intervals will allow the time, cause, and effect of navigation system weaknesses to be identified. In addition, by modeling a sufficient set of navigation system errors, a system failure that causes an observed error anomaly can be traced and accounted for. The GEAS software is formulated using Object Oriented Design (OOD) techniques implemented in the C++ programming language on a Sun SPARC workstation. The Phase 1 of this effort is the development of a basic system to be used to evaluate navigation algorithms implemented in the GEODE system. This paper presents the GEAS mathematical methodology, systems and operations concepts, and software design and implementation. Results from the use of the basic system to evaluate

  16. Innovative optical power detection array system for relative positioning of inner-formation flying system

    Science.gov (United States)

    Hou, Zhendong; Wang, Zhaokui; Zhang, Yulin

    2016-09-01

    The Inner-formation flying system (IFFS) is conceived to feature a spherical proof mass falling freely within a large cavity for space gravity detection, of which first application focuses on the Earth's gravity field recovery. For the IFFS, it is the relative position of the proof mass to its surrounding cavity that is feedback into thrusters for tracking control, even as part of data to detect gravity. Since the demonstration and verification of demanding technologies using small satellite platforms is a very sensible choice prior to detection mission, an optical power detection array system (OPDAS) is proposed to measure the relative position with advantages of low cost and high adaptability. Besides that, its large dynamic range can reduce the requirement for satellite platform and releasing mechanism, which is also an attracting trait for small satellite application. The concept of the OPDAS is firstly presented, followed by the algorithm to position the proof mass. Then the radiation pressure caused by the measuring beam is modeled, and its disturbance on the proof mass is simulated. The experimental system to test the performance of a prototype of the OPDAS is established, and the preliminary results show that a precision of less than 0.4 mm across a dynamic range of several centimeters can be reached by the prototype of the OPDAS.

  17. The ALTA global positioning satellite based timing system

    CERN Document Server

    Brouwer, W; Caron, B; Hewlett, J C; Holm, L; Hamilton, A H; McDonald, W J; Pinfold, J L; Schaapman, J R; Soluk, R A; Wampler, L J

    2002-01-01

    The Alberta Large-area Time-coincidence Array (ALTA) experiment uses a number of scintillation detector systems to form a sparse very large area cosmic air-shower detection array. An important scientific goal of the ALTA collaboration is to search for coincidences in the ALTA array due to large area cosmic ray phenomena. A local cosmic ray event, determined by a coincidence of the triplet of cosmic ray detectors forming a local detector system, is time stamped with a temporal coordinate obtained from a GPS receiver. The readout of the data, the local coincidence and the GPS time stamp are all performed in the local readout crate. This time stamp, along with the local shower direction is used to search for coincidences within the large area array. Using two GPS receivers and duplicate sets of ALTA electronics the timing resolution of the GPS time difference between sites was estimated to be 16 ns.

  18. Lunar power systems. Final report

    International Nuclear Information System (INIS)

    1986-12-01

    The findings of a study on the feasibility of several methods of providing electrical power for a permanently manned lunar base are provided. Two fundamentally different methods for lunar electrical power generation are considered. One is the use of a small nuclear reactor and the other is the conversion of solar energy to electricity. The baseline goal was to initially provide 300 kW of power with growth capability to one megawatt and eventually to 10 megawatts. A detailed, day by day scenario for the establishment, build-up, and operational activity of the lunar base is presented. Also presented is a conceptual approach to a supporting transportation system which identifies the number, type, and deployment of transportation vehicles required to support the base. An approach to the use of solar cells in the lunar environment was developed. There are a number of heat engines which are applicable to solar/electric conversions, and these are examined. Several approaches to energy storage which were used by the electric power utilities were examined and those which could be used at a lunar base were identified

  19. Estimation of Subdaily Polar Motion with the Global Positioning System During the Spoch '92 Campaign

    Science.gov (United States)

    Ibanez-Meier, R.; Freedman, A. P.; Herring, T. A.; Gross, R. S.; Lichten, S. M.; Lindqwister, U. J.

    1994-01-01

    Data collected over six days from a worldwide Global Positioning System (GPS) tracking network during the Epoch '92 campaign are used to estimate variations of the Earth's pole position every 30 minutes.

  20. Accuracy of position measurement method using Arago spot for inertial fusion energy target tracking system

    International Nuclear Information System (INIS)

    Saruta, Koichi; Tsuji, Ryusuke

    2007-01-01

    The accuracy of a position measurement method using the Arago spot is reported for an inertial fusion energy (IFE) target tracking system, where the position of the target is determined by the position of the Arago spot, which is a bright spot appearing in the central portion of the diffraction pattern of a spherical obstacle. We use a He-Ne laser as the light source and a charge-coupled device (CCD) camera with a microscope objective lens to magnify and record the diffraction pattern of a spherical target. We examine two different algorithms to determine the center of the Arago spot in order to compare the measurement performances. The experimental results show that the position of a 5-mm-diameter target can be obtained with a measurement resolution of 1 μm and an rms measurement error of less than 0.2μm for both algorithms when the distance between the target and the microscope objective lens is 5 cm. (author)

  1. HER2-positive male breast cancer with thyroid cancer: an institutional report and review of literature.

    Science.gov (United States)

    Bardhan, Pooja; Bui, Marilyn M; Minton, Susan; Loftus, Loretta; Carter, W Bradford; Laronga, Christine; Ismail-Khan, Roohi

    2012-01-01

    We report a rare finding of two male breast cancer patients with HER2-positive breast cancer who also developed thyroid cancer. We reviewed 45 male breast cancer patients treated in our institution from 2003 to 2008. Only five male breast cancer patients were HER2-positive. In reviewing the published data, we found no cases of thyroid cancer and concurrent breast cancer in men. However, breast cancer and thyroid cancer have shown close association in women. This finding therefore provokes speculation as to whether we should investigate whether women with HER2-positive breast cancer are at a higher risk for thyroid cancer. Although this observation seems to be clinically prevalent, publications are sparse in clinical research areas linking thyroid cancer to breast cancer.

  2. DIFFICULTIES RELATED TO THE FINANCIAL POSITION REPORTING INTO THE PUBLIC SECTOR IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Aurelia ŞTEFĂNESCU

    2014-11-01

    Full Text Available Within the context of a turbulent economic environment with impact on the vulnerability of the public sector entities, the stakeholders’ needs of information are focussed on the assessment of liquidities and their solvency, on the sustenability of service offerring, as well as on the capacity of the entities to answer a dynamic environment in terms of cost, quality and continuity. In this respect, the current study has as objective to identify the difficulties of reporting the financial position into the public sector in Romania. In order to reach the proposed objective, an interpretative research methodology was used. The results of this study has pointed out that the prevalence of divergences between the national view versus IPSAS in terms of reporting the financial position into the public sector limits the informational value and its relevance both for the management of the entities and their stakeholders.

  3. First report of sasX-positive methicillin-resistant Staphylococcus aureus in Japan.

    Science.gov (United States)

    Nakaminami, Hidemasa; Ito, Teruyo; Han, Xiao; Ito, Ayumu; Matsuo, Miki; Uehara, Yuki; Baba, Tadashi; Hiramatsu, Keiichi; Noguchi, Norihisa

    2017-09-01

    SasX is a known virulence factor of Staphylococcus aureus involved in colonisation and immune evasion of the bacterium. The sasX gene, which is located on the ϕSPβ prophage, is frequently found in the sequence type (ST) 239 S. aureus lineage, which is the predominant healthcare-associated clone in Asian countries. In Japan, ST239 clones have rarely been identified, and sasX-positive strains have not been reported to date. Here, we report the first identification of 18 sasX-positive methicillin-resistant S. aureus (MRSA) strains in Japanese hospitals between 2009 and 2011. All sasX-positive isolates belonged to an ST239-staphylococcal cassette chromosome mec type III (ST239-III) lineage. However, we were unable to identify additional sasX-positive MRSA strains from 2012 to 2016, indicating that the small epidemic of sasX-positive isolates observed in this study was temporary. The sequence surrounding sasX in the strain TOHH628 lacked 51 genes that encode phage packaging and structural proteins, and no bacteriophage was induced by mitomycin C. Additionally, in the TOHH628 strain, the region (64.6 kb) containing sasX showed high identity to the ϕSPβ-like element (71.3 kb) of the Taiwanese MRSA strain Z172. The data strongly suggest that the present sasX-positive isolates found in Japanese hospitals were transmitted incidentally from other countries. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. 31 CFR 356.13 - When must I report my net long position and how do I calculate it?

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false When must I report my net long position and how do I calculate it? 356.13 Section 356.13 Money and Finance: Treasury Regulations Relating... net long position and how do I calculate it? (a) Net long position reporting threshold. (1) If you are...

  5. DIFFICULTIES RELATED TO THE FINANCIAL POSITION REPORTING INTO THE PUBLIC SECTOR IN ROMANIA

    OpenAIRE

    Aurelia ŞTEFĂNESCU

    2014-01-01

    Within the context of a turbulent economic environment with impact on the vulnerability of the public sector entities, the stakeholders’ needs of information are focussed on the assessment of liquidities and their solvency, on the sustenability of service offerring, as well as on the capacity of the entities to answer a dynamic environment in terms of cost, quality and continuity. In this respect, the current study has as objective to identify the difficulties of reporting the financial posit...

  6. Autonomous Car Parking System through a Cooperative Vehicular Positioning Network.

    Science.gov (United States)

    Correa, Alejandro; Boquet, Guillem; Morell, Antoni; Lopez Vicario, Jose

    2017-04-13

    The increasing development of the automotive industry towards a fully autonomous car has motivated the design of new value-added services in Vehicular Sensor Networks (VSNs). Within the context of VSNs, the autonomous car, with an increasing number of on-board sensors, is a mobile node that exchanges sensed and state information within the VSN. Among all the value added services for VSNs, the design of new intelligent parking management architectures where the autonomous car will coexist with traditional cars is mandatory in order to profit from all the opportunities associated with the increasing intelligence of the new generation of cars. In this work, we design a new smart parking system on top of a VSN that takes into account the heterogeneity of cars and provides guidance to the best parking place for the autonomous car based on a collaborative approach that searches for the common good of all of them measured by the accessibility rate, which is the ratio of the free parking places accessible for an autonomous car. Then, we simulate a real parking lot and the results show that the performance of our system is close to the optimum considering different communication ranges and penetration rates for the autonomous car.

  7. Autonomous Car Parking System through a Cooperative Vehicular Positioning Network

    Science.gov (United States)

    Correa, Alejandro; Boquet, Guillem; Morell, Antoni; Lopez Vicario, Jose

    2017-01-01

    The increasing development of the automotive industry towards a fully autonomous car has motivated the design of new value-added services in Vehicular Sensor Networks (VSNs). Within the context of VSNs, the autonomous car, with an increasing number of on-board sensors, is a mobile node that exchanges sensed and state information within the VSN. Among all the value added services for VSNs, the design of new intelligent parking management architectures where the autonomous car will coexist with traditional cars is mandatory in order to profit from all the opportunities associated with the increasing intelligence of the new generation of cars. In this work, we design a new smart parking system on top of a VSN that takes into account the heterogeneity of cars and provides guidance to the best parking place for the autonomous car based on a collaborative approach that searches for the common good of all of them measured by the accessibility rate, which is the ratio of the free parking places accessible for an autonomous car. Then, we simulate a real parking lot and the results show that the performance of our system is close to the optimum considering different communication ranges and penetration rates for the autonomous car. PMID:28406426

  8. Energy Innovation Systems Indicator Report 2012

    DEFF Research Database (Denmark)

    Klitkou, Antje; Borup, Mads; Iversen, Eric

    This report is the first report in a series of reports on energy innovation system indicators produced as part of the activities in the “EIS Strategic research alliance for Energy Innovation Systems and their dynamics – Denmark in global competition”. The work is based on a number of existing......). The report received also valuable input from a project commissioned by IPTS. This project addressed co-operation patterns and knowledge flows in patent documents in the fields of wind energy, photovoltaic energy and concentrating solar power (Iversen and Patel, 2010). The results relevant for this project...

  9. Positive impact of hormone replacement therapy on the fibrinolytic system

    DEFF Research Database (Denmark)

    Madsen, J S; Kristensen, S R; Gram, J

    2003-01-01

    be of importance. OBJECTIVES: To investigate the prolonged effect of HRT on the fibrinolytic system and to determine whether two common polymorphisms in the plasminogen activator inhibitor-1 (PAI-1) and tissue-type plasminogen activator (t-PA) genes modulate this effect. Methods: Healthy postmenopausal women (n...... = 248) were randomized to HRT (n = 122) or no substitution (n = 126) 5 years prior to investigation. RESULTS: Significantly higher values of t-PA activity and lower values of PAI-1 activity and PAI-1 antigen were found in the HRT group compared with the control group. This effect was independent...... of smoking and without influence from the two common polymorphisms PAI-1 -675(4G/5G) and t-PA intron8ins311. Furthermore, no difference between opposed estrogen (with norethisterone acetate as the gestagen component) and unopposed estrogen therapy was found. Both an intention-to-treat and a per...

  10. Severe bronchopulmonary dysplasia improved by noninvasive positive pressure ventilation: a case report

    Directory of Open Access Journals (Sweden)

    Mann Christian

    2011-09-01

    Full Text Available Abstract Introduction This is the first report to describe the feasibility and effectiveness of noninvasive positive pressure ventilation in the secondary treatment of bronchopulmonary dysplasia. Case presentation A former male preterm of Caucasian ethnicity delivered at 29 weeks gestation developed severe bronchopulmonary dysplasia. At the age of six months he was in permanent tachypnea and dyspnea and in need of 100% oxygen with a flow of 2.0 L/minute via a nasal cannula. Intermittent nocturnal noninvasive positive pressure ventilation was then administered for seven hours daily. The ventilator was set at a positive end-expiratory pressure of 6 cmH2O, with pressure support of 4 cmH2O, trigger at 1.4 mL/second, and a maximum inspiratory time of 0.7 seconds. Over the course of seven weeks, the patient's maximum daytime fraction of inspired oxygen via nasal cannula decreased from 1.0 to 0.75, his respiratory rate from 64 breaths/minute to 50 breaths/minute and carbon dioxide from 58 mmHg to 44 mmHg. Conclusion Noninvasive positive pressure ventilation may be a novel therapeutic option for established severe bronchopulmonary dysplasia. In the case presented, noninvasive positive pressure ventilation achieved sustained improvement in ventilation and thus prepared our patient for safe home oxygen therapy.

  11. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.

    Science.gov (United States)

    Polley, John W; Figueroa, Alvaro A

    2013-05-01

    To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. 75 FR 2581 - Eighty-First Meeting: RTCA Special Committee 159: Global Positioning System (GPS)

    Science.gov (United States)

    2010-01-15

    ... Committee 159: Global Positioning System (GPS) AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 159 meeting: Global Positioning System (GPS). SUMMARY: The FAA is... System (GPS). DATES: The meeting will be held February 2-5, 2010, from 9 a.m. to 4:30 p.m. (unless stated...

  13. 76 FR 27744 - Eighty-Fifth Meeting: RTCA Special Committee 159: Global Positioning System (GPS)

    Science.gov (United States)

    2011-05-12

    ... Committee 159: Global Positioning System (GPS) AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 159 meeting: Global Positioning System (GPS). SUMMARY: The FAA is... System (GPS). DATES: The meeting will be held May 26, 2011, from 9 a.m. to 11:45 a.m. ADDRESSES: The...

  14. 76 FR 67019 - Eighty-Seventh: RTCA Special Committee 159: Global Positioning System (GPS)

    Science.gov (United States)

    2011-10-28

    ... Committee 159: Global Positioning System (GPS) AGENCY: Federal Aviation Administration (FAA), U.S... System (GPS). SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 159: Global Positioning System (GPS) 87th meeting. DATES: The meeting will be held November 14-18...

  15. 76 FR 33022 - Eighty-Sixth Meeting: RTCA Special Committee 159: Global Positioning System (GPS)

    Science.gov (United States)

    2011-06-07

    ... Committee 159: Global Positioning System (GPS) AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 159 meeting: Global Positioning System (GPS). SUMMARY: The FAA is... System (GPS). DATES: The meeting will be held June 13-17, 2011, from 9 a.m. to 4:30 p.m. ADDRESSES: The...

  16. 78 FR 979 - Petition for Positive Train Control Safety Plan Approval and System Certification of the...

    Science.gov (United States)

    2013-01-07

    ...] Petition for Positive Train Control Safety Plan Approval and System Certification of the Electronic Train... the Federal Railroad Administration (FRA) for Positive Train Control (PTC) Safety Plan (PTCSP) approval and system certification of the Electronic Train Management System (ETMS) as required by 49 U.S.C...

  17. Army Energy and Water Reporting System Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Deprez, Peggy C.; Giardinelli, Michael J.; Burke, John S.; Connell, Linda M.

    2011-09-01

    There are many areas of desired improvement for the Army Energy and Water Reporting System. The purpose of system is to serve as a data repository for collecting information from energy managers, which is then compiled into an annual energy report. This document summarizes reported shortcomings of the system and provides several alternative approaches for improving application usability and adding functionality. The U.S. Army has been using Army Energy and Water Reporting System (AEWRS) for many years to collect and compile energy data from installations for facilitating compliance with Federal and Department of Defense energy management program reporting requirements. In this analysis, staff from Pacific Northwest National Laboratory found that substantial opportunities exist to expand AEWRS functions to better assist the Army to effectively manage energy programs. Army leadership must decide if it wants to invest in expanding AEWRS capabilities as a web-based, enterprise-wide tool for improving the Army Energy and Water Management Program or simply maintaining a bottom-up reporting tool. This report looks at both improving system functionality from an operational perspective and increasing user-friendliness, but also as a tool for potential improvements to increase program effectiveness. The authors of this report recommend focusing on making the system easier for energy managers to input accurate data as the top priority for improving AEWRS. The next major focus of improvement would be improved reporting. The AEWRS user interface is dated and not user friendly, and a new system is recommended. While there are relatively minor improvements that could be made to the existing system to make it easier to use, significant improvements will be achieved with a user-friendly interface, new architecture, and a design that permits scalability and reliability. An expanded data set would naturally have need of additional requirements gathering and a focus on integrating

  18. Factors associated with false-positive self-reported adherence to antihypertensive drugs.

    Science.gov (United States)

    Tedla, Y G; Bautista, L E

    2017-05-01

    Self-reported medication adherence is known to overestimate true adherence. However, little is known about patient factors that may contribute to the upward bias in self-reported medication adherence. The objective of this study is to examine whether demographic, behavioral, medication and mood factors are associated with being a false-positive self-reported adherer (FPA) to antihypertensive drug treatment. We studied 175 patients (mean age: 50 years; 57% men) from primary-care clinics starting antihypertensive drug treatment. Self-reported adherence (SRA) was measured with the Medication Adherence Report Scale (MARS) and by the number of drug doses missed in the previous week/month, and compared with pill count adherence ratio (PCAR) as gold standard. Data on adherence, demographic, behavioral, medication and mood factors were collected at baseline and every 3 months up to 1 year. FPA was defined as being a non-adherer by PCAR and an adherer by self-report. Mixed effect logistic regression was used for the analysis. Twenty percent of participants were FPA. Anxiety increased (odds ratio (OR): 3.00; P=0.01), whereas smoking (OR: 0.40; P=0.03) and drug side effects (OR: 0.46, P=0.03) decreased the probability for FPA by MARS. Education below high-school completion increased the probability of being an FPA as measured by missing doses in the last month (OR: 1.66; P=0.04) and last week (OR: 1.88; P=0.02). The validity of SRA varies significantly according to drug side effects, behavioral factors and patient's mood. Careful consideration should be given to the use of self-reported measures of adherence among patients likely to be false-positive adherers.

  19. Precision position control of servo systems using adaptive back-stepping and recurrent fuzzy neural networks

    International Nuclear Information System (INIS)

    Kim, Han Me; Kim, Jong Shik; Han, Seong Ik

    2009-01-01

    To improve position tracking performance of servo systems, a position tracking control using adaptive back-stepping control(ABSC) scheme and recurrent fuzzy neural networks(RFNN) is proposed. An adaptive rule of the ABSC based on system dynamics and dynamic friction model is also suggested to compensate nonlinear dynamic friction characteristics. However, it is difficult to reduce the position tracking error of servo systems by using only the ABSC scheme because of the system uncertainties which cannot be exactly identified during the modeling of servo systems. Therefore, in order to overcome system uncertainties and then to improve position tracking performance of servo systems, the RFNN technique is additionally applied to the servo system. The feasibility of the proposed control scheme for a servo system is validated through experiments. Experimental results show that the servo system with ABS controller based on the dual friction observer and RFNN including the reconstruction error estimator can achieve desired tracking performance and robustness

  20. Position Paper: Designing Complex Systems to Support Interdisciplinary Cognitive Work

    Science.gov (United States)

    Greene, Melissa T.; Papalambros, Panos Y.; Mcgowan, Anna-Maria R.

    2016-01-01

    The paper argues that the field we can call cognitive science of interdisciplinary collaboration is an important area of study for improving design of Large-Scale Complex Systems (LaCES) and supporting cognitive work. The paper mostly raised questions that have been documented in earlier qualitative analysis studies, and provided possible avenues of exploration for addressing them. There are likely further contributions from additional disciplines beyond those mentioned in this paper that should be considered and integrated into such a cognitive science framework. Knowledge and awareness of various perspectives will help to inform the types of interventions available for improving LaCES design and functionality. For example, a cognitive interpretation of interdisciplinary collaborations in LaCES elucidated the need for a "translator" or "mediator" in helping subject matter experts to transcend language boundaries, mitigate single discipline bias, support integrative activities, and correct misaligned objectives. Additional research in this direction is likely to uncover similar gaps and opportunities for improvements in practice.

  1. Real Time Decoding of Color Symbol for Optical Positioning System

    Directory of Open Access Journals (Sweden)

    Abdul Waheed Malik

    2015-01-01

    Full Text Available This paper presents the design and real-time decoding of a color symbol that can be used as a reference marker for optical navigation. The designed symbol has a circular shape and is printed on paper using two distinct colors. This pair of colors is selected based on the highest achievable signal to noise ratio. The symbol is designed to carry eight bit information. Real time decoding of this symbol is performed using a heterogeneous combination of Field Programmable Gate Array (FPGA and a microcontroller. An image sensor having a resolution of 1600 by 1200 pixels is used to capture images of symbols in complex backgrounds. Dynamic image segmentation, component labeling and feature extraction was performed on the FPGA. The region of interest was further computed from the extracted features. Feature data belonging to the symbol was sent from the FPGA to the microcontroller. Image processing tasks are partitioned between the FPGA and microcontroller based on data intensity. Experiments were performed to verify the rotational independence of the symbols. The maximum distance between camera and symbol allowing for correct detection and decoding was analyzed. Experiments were also performed to analyze the number of generated image components and sub-pixel precision versus different light sources and intensities. The proposed hardware architecture can process up to 55 frames per second for accurate detection and decoding of symbols at two Megapixels resolution. The power consumption of the complete system is 342mw.

  2. A COMPARATIVE ANALYSIS OF GLOBAL POSITIONING SYSTEM SCHEMES BASED ON BLOCK CODES

    OpenAIRE

    Prasad Janga; Dr. R. L. Sharma

    2017-01-01

    Global Positioning System (GPS) is a satellite based positioning system based on radio ranging technique. The GPS will provide very accurate three-dimensional position, velocity and timing information to users anywhere in the world. GPS can also be used in other applications such as vehicle monitoring for traffic management in urban areas, Geographical Information System (GIS), 4G Communications, marine navigation, search and rescue and military applications. As GPS accuracy is limited by ion...

  3. The NASA Aviation Safety Reporting System

    Science.gov (United States)

    1983-01-01

    This is the fourteenth in a series of reports based on safety-related incidents submitted to the NASA Aviation Safety Reporting System by pilots, controllers, and, occasionally, other participants in the National Aviation System (refs. 1-13). ASRS operates under a memorandum of agreement between the National Aviation and Space Administration and the Federal Aviation Administration. The report contains, first, a special study prepared by the ASRS Office Staff, of pilot- and controller-submitted reports related to the perceived operation of the ATC system since the 1981 walkout of the controllers' labor organization. Next is a research paper analyzing incidents occurring while single-pilot crews were conducting IFR flights. A third section presents a selection of Alert Bulletins issued by ASRS, with the responses they have elicited from FAA and others concerned. Finally, the report contains a list of publications produced by ASRS with instructions for obtaining them.

  4. Intelligent Transportation Systems statewide architecture : final report.

    Science.gov (United States)

    2003-06-01

    This report describes the development of Kentuckys Statewide Intelligent Transportation Systems (ITS) Architecture. The process began with the development of an ITS Strategic Plan in 1997-2000. A Business Plan, developed in 2000-2001, translated t...

  5. Traffic Management Systems Performance Measurement: Final Report

    OpenAIRE

    Banks, James H.; Kelly, Gregory

    1997-01-01

    This report documents a study of performance measurement for Transportation Management Centers (TMCs). Performance measurement requirements were analyzed, data collection and management techniques were investigated, and case study traffic data system improvement plans were prepared for two Caltrans districts.

  6. Grants Reporting and Tracking System (GRTS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Grants Reporting and Tracking System (GRTS) is the primary tool for management and oversight of EPA's Nonpoint Source (NPS) Pollution Control Program. GRTS pulls...

  7. National Violent Death Reporting System (NVDRS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Violent Death Reporting System (NVDRS) provides states and communities with a clearer understanding of violent deaths to guide local decisions about...

  8. FOXP3 positive regulatory T-cells in cutaneous and systemic CD30 positive T-cell lymphoproliferations

    DEFF Research Database (Denmark)

    Gjerdrum, Lise Mette; Woetmann, Anders; Ødum, Niels

    2008-01-01

    for FOXP3 expression in tumour cells and tumour infiltrating Tregs. Labelling of a majority of the neoplastic cells was seen in one case of C-ALCL. Another three cases (one LyP and two C-ALCL) displayed weak labelling of very occasional atypical T-cells. In the remaining 38 cases the atypical lymphoid...... infiltrate was FOXP3 negative. By contrast, all biopsies contained tumour infiltrating FOXP3-positive Tregs. Significant higher numbers were recorded in ALK negative S-ALCL and LyP than in C-ALCL and S-ALCL positive for ALK. In conclusion, it is shown that FOXP3 expression in cutaneous and systemic CD30...

  9. Research on correction algorithm of laser positioning system based on four quadrant detector

    Science.gov (United States)

    Gao, Qingsong; Meng, Xiangyong; Qian, Weixian; Cai, Guixia

    2018-02-01

    This paper first introduces the basic principle of the four quadrant detector, and a set of laser positioning experiment system is built based on the four quadrant detector. Four quadrant laser positioning system in the actual application, not only exist interference of background light and detector dark current noise, and the influence of random noise, system stability, spot equivalent error can't be ignored, so it is very important to system calibration and correction. This paper analyzes the various factors of system positioning error, and then propose an algorithm for correcting the system error, the results of simulation and experiment show that the modified algorithm can improve the effect of system error on positioning and improve the positioning accuracy.

  10. BDS/GPS Dual Systems Positioning Based on the Modified SR-UKF Algorithm

    Directory of Open Access Journals (Sweden)

    JaeHyok Kong

    2016-05-01

    Full Text Available The Global Navigation Satellite System can provide all-day three-dimensional position and speed information. Currently, only using the single navigation system cannot satisfy the requirements of the system’s reliability and integrity. In order to improve the reliability and stability of the satellite navigation system, the positioning method by BDS and GPS navigation system is presented, the measurement model and the state model are described. Furthermore, the modified square-root Unscented Kalman Filter (SR-UKF algorithm is employed in BDS and GPS conditions, and analysis of single system/multi-system positioning has been carried out, respectively. The experimental results are compared with the traditional estimation results, which show that the proposed method can perform highly-precise positioning. Especially when the number of satellites is not adequate enough, the proposed method combine BDS and GPS systems to achieve a higher positioning precision.

  11. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    Science.gov (United States)

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Preoperational test report, primary ventilation condensate system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-01-29

    Preoperational test report for Primary Ventilation Condensate System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides a collection point for condensate generated by the W-030 primary vent offgas cooling system serving tanks AYIOI, AY102, AZIOI, AZI02. The system is located inside a shielded ventilation equipment cell and consists of a condensate seal pot, sampling features, a drain line to existing Catch Tank 241-AZ-151, and a cell sump jet pump. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  13. Traceability of biopharmaceuticals in spontaneous reporting systems

    DEFF Research Database (Denmark)

    Vermeer, Niels S; Straus, Sabine M J M; Mantel-Teeuwisse, Aukje K

    2013-01-01

    the period 2004-2010, including ADR reports from two major SRSs: the FDA Adverse Event Reporting System (FAERS) in the US and EudraVigilance (EV) in the EU. MAIN OUTCOME MEASURES: The availability of batch numbers was determined for biopharmaceuticals, and compared with small molecule drugs...

  14. The Retinal Readout System: a status report A Status Report

    CERN Document Server

    Litke, A M

    1999-01-01

    The 'Retinal Readout System' is being developed to study the language the eye uses to send information about the visual world to the brain. Its architecture is based on that of silicon microstrip detectors. An array of 512 microscopic electrodes picks up the signals generated by the output neurons of live retinal tissue in response to a dynamic image focused on the input neurons. These signals are amplified, filtered and multiplexed by a set of eight custom-designed VLSI readout chips, and digitized and recorded by a data acquisition system. This report describes the goals, design, and status of the system. (author)

  15. NEA incident reporting system: Three years' experience

    International Nuclear Information System (INIS)

    Otsuka, Y.; Haeussermann, W.

    1984-01-01

    The paper presents an overview of the NEA Incident Reporting System (IRS) which was set up to collect, assess and disseminate on safety-related incidents in nuclear power plants. The IRS information exchange is significant in two senses. First, it enables regulatory authorities and utilities in participating countries to take appropriate action to prevent the reported mishaps occurring again elsewhere. Secondly, the continuous collection and systematic analysis of such information allows identification of areas of concern where safety research should be strengthened. There are two stages in the IRS information exchange. First, the national IRS Co-ordinator selects information on significant incidents, in accordance with a common reporting threshold, from the abnormal occurrences reported to the regulatory body, to be distributed through the NEA Secretariat. This screening is intended to exclude minor events, so that only significant information is sent to participating countries. Secondly, a group of experts periodically reviews the incidents reported during the preceding twelve months to identify major areas of concern. To assist this process, a computer-based data retrieval system is being developed for IRS incident reports. The paper gives some details of the IRS mechanism and discusses reporting criteria and the information included in a report. Areas of concern derived from reported incidents, an outline of the data retrieval system, and examples of feedback of lessons learned and possibilities for international co-operation are also discussed. (author)

  16. Aviation Safety Reporting System: Process and Procedures

    Science.gov (United States)

    Connell, Linda J.

    1997-01-01

    The Aviation Safety Reporting System (ASRS) was established in 1976 under an agreement between the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA). This cooperative safety program invites pilots, air traffic controllers, flight attendants, maintenance personnel, and others to voluntarily report to NASA any aviation incident or safety hazard. The FAA provides most of the program funding. NASA administers the program, sets its policies in consultation with the FAA and aviation community, and receives the reports submitted to the program. The FAA offers those who use the ASRS program two important reporting guarantees: confidentiality and limited immunity. Reports sent to ASRS are held in strict confidence. More than 350,000 reports have been submitted since the program's beginning without a single reporter's identity being revealed. ASRS removes all personal names and other potentially identifying information before entering reports into its database. This system is a very successful, proof-of-concept for gathering safety data in order to provide timely information about safety issues. The ASRS information is crucial to aviation safety efforts both nationally and internationally. It can be utilized as the first step in safety by providing the direction and content to informed policies, procedures, and research, especially human factors. The ASRS process and procedures will be presented as one model of safety reporting feedback systems.

  17. Tension - Type - Headache treated by Positional Release Therapy: a case report.

    Science.gov (United States)

    Mohamadi, Marzieh; Ghanbari, Ali; Rahimi Jaberi, Abbas

    2012-10-01

    Tension Type Headache (T.T.H) is the most prevalent headache. Myofascial abnormalities & trigger points are important in this type of headache which can be managed by Positional Release Therapy (PRT). This is a report of a 47 years old female patient with Tension Type Headache treated by Positional Release Therapy for her trigger points. She had a constant dull headache, which continued all the day for 9 months. A physiotherapist evaluated the patient and found active trigger points in her cervical muscles. Then, she received Positional Release Therapy for her trigger points. After 3 treatment sessions, the patient's headache stopped completely. During the 8 months following the treatment she was without pain, and did not use any medication. Positional Release Therapy was effective in treating Tension Type Headache. This suggests that PRT could be an alternative treatment to medication in patients with T.T.H if the effectiveness of that can be confirmed by further studies. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Molecular Imaging with Activatable Reporter Systems

    Directory of Open Access Journals (Sweden)

    Gang Niu, Xiaoyuan Chen

    2012-01-01

    Full Text Available Molecular imaging is a newly emerged multiple disciplinary field that aims to visualize, characterize and quantitatively measure biological processes at cellular and molecular levels in humans and other living systems. A reporter gene is a piece of DNA encoding reporter protein, which presents as a readily measurable phenotype that can be distinguished easily from the background of endogenous protein. After being transferred into cells of organ systems (transgenes, the reporter gene can be utilized to visualize transcriptional and posttranscriptional regulation of gene expression, protein-protein interactions, or trafficking of proteins or cells in living subjects. Herein, we review previous classification of reporter genes and regroup the reporter gene based imaging as basic, inducible and activatable, based on the regulation of reporter gene transcription and post-translational modification of reporter proteins. We then focus on activatable reporters, in which the signal can be activated at the posttranslational level for visualizing protein-protein interactions, protein phosphorylation or tertiary structure changes. The applications of several types of activatable reporters will also be summarized. We conclude that activatable reporter imaging can benefit both basic biomedical research and drug development.

  19. Consultation system for image diagnosis: Report formation support system

    International Nuclear Information System (INIS)

    Ikeda, M.; Sakuma, S.; Ishigaki, T.; Suzuki, K.; Oikawa, K.

    1987-01-01

    The authors developed a consultation system for image diagnosis, involving artificial intelligence ideas. In this system, the authors proposed a new report formation support system and implemented it in lymphangiography. This support system starts with the input of image interpretation. The input process is made mainly by selecting items. This system encodes the input findings into the semantic network, which is represented as a directed graph, and it reserves them into the knowledge database in the above structure. Finally, the output (report) is made in the near natural language, which corresponds to the input findings

  20. Cedar Avenue driver assist system evaluation report.

    Science.gov (United States)

    2011-12-01

    This paper summarizes an evaluation of the Driver Assist System (DAS) used by the Minnesota Valley Transit Authority (MTVA) for bus shoulder operations. The DAS is a GPS-based technology suite that provides lane-position feedback to the driver via a ...

  1. Systems Analysis Department annual progress report 1999

    DEFF Research Database (Denmark)

    2000-01-01

    This report describes the work of the Systems Analysis Department at Risø National Laboratory during 1999. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning - UNEP Centre, Safety,Realiability and Human Factors, and Technology...

  2. Affirmative Action Data Collection and Reporting System.

    Science.gov (United States)

    McLean, Marquita; And Others

    A computerized Affirmative Action Data Collection and Reporting System was implemented at the University of Cincinnati to assist in monitoring the progress of the University's Affirmative Action program. The benefits derived from the system were definitely a contributing factor in the University's successful attempt to have its Affirmative Action…

  3. 1998 FFTF annual system assessment reports

    International Nuclear Information System (INIS)

    Guttenberg, S.

    1998-01-01

    The health of FFTF systems was assessed assuming a continued facility standby condition. The review was accomplished in accordance with the guidelines of FFTF-EI-083, Plant Evaluation Program. The attached document includes an executive summary of the significant conclusions and assessment reports for each system evaluated

  4. 1998 FFTF annual system assessment reports

    Energy Technology Data Exchange (ETDEWEB)

    Guttenberg, S.

    1998-03-19

    The health of FFTF systems was assessed assuming a continued facility standby condition. The review was accomplished in accordance with the guidelines of FFTF-EI-083, Plant Evaluation Program. The attached document includes an executive summary of the significant conclusions and assessment reports for each system evaluated.

  5. New approach for control rod position indication system for light water power reactor

    International Nuclear Information System (INIS)

    Bahuguna, Sushil; Dhage, Sangeeta; Nawaj, S.; Salek, C.; Lahiri, S.K.; Marathe, P.P.; Mukhopadhyay, S.; Taly, Y.K.

    2015-01-01

    Control rod position indication system is an important system in a nuclear power plant to monitor and display control rod position in all regimes of reactor operation. A new approach to design a control rod position indication system for sensing absolute position of control rod in Light Water Power Reactor has been undertaken. The proposed system employs an inductive type, hybrid measurement strategy providing both analog position as well as digital zone indication with built-in temperature compensation. The new design approach meets single failure criterion through redundancy in design without sacrificing measurement resolution. It also provides diversity in measurement technique by indirect position sensing based on analysis of drive coil current signature. Prototype development and qualification at room temperature of the control rod position indication system (CRPIS) has been demonstrated. The article presents the design philosophy of control rod position indication system, the new measurement strategy for sensing absolute position of control rod, position estimation algorithm for both direct and indirect sensing and a brief account associated processing electronics. (author)

  6. An automated online positioning system and simulation environment for multi-electrodes in extracellular recordings

    DEFF Research Database (Denmark)

    Franke, Felix; Natora, Michal; Meier, Philipp

    2010-01-01

    to tissue drifts and other sources of variability in the recording setup, the position of the electrodes with respect to the recorded neurons can change causing low recording quality. The contributions of this work are threefold. We introduce a quality measure for the recording position of the electrode...... which should be maximized during recordings and is especially suitable for the use of multi-electrodes. An automated positioning system based on this quality measure is proposed. The system is able to find favorable recording positions and adapts the electrode position smoothly to changes of the neuron...

  7. Integrating remote sensing, geographic information systems and global positioning system techniques with hydrological modeling

    Science.gov (United States)

    Thakur, Jay Krishna; Singh, Sudhir Kumar; Ekanthalu, Vicky Shettigondahalli

    2017-07-01

    Integration of remote sensing (RS), geographic information systems (GIS) and global positioning system (GPS) are emerging research areas in the field of groundwater hydrology, resource management, environmental monitoring and during emergency response. Recent advancements in the fields of RS, GIS, GPS and higher level of computation will help in providing and handling a range of data simultaneously in a time- and cost-efficient manner. This review paper deals with hydrological modeling, uses of remote sensing and GIS in hydrological modeling, models of integrations and their need and in last the conclusion. After dealing with these issues conceptually and technically, we can develop better methods and novel approaches to handle large data sets and in a better way to communicate information related with rapidly decreasing societal resources, i.e. groundwater.

  8. NASA Aviation Safety Reporting System (ASRS)

    Science.gov (United States)

    Connell, Linda J.

    2017-01-01

    The NASA Aviation Safety Reporting System (ASRS) collects, analyzes, and distributes de-identified safety information provided through confidentially submitted reports from frontline aviation personnel. Since its inception in 1976, the ASRS has collected over 1.4 million reports and has never breached the identity of the people sharing their information about events or safety issues. From this volume of data, the ASRS has released over 6,000 aviation safety alerts concerning potential hazards and safety concerns. The ASRS processes these reports, evaluates the information, and provides selected de-identified report information through the online ASRS Database at http:asrs.arc.nasa.gov. The NASA ASRS is also a founding member of the International Confidential Aviation Safety Systems (ICASS) group which is a collection of other national aviation reporting systems throughout the world. The ASRS model has also been replicated for application to improving safety in railroad, medical, fire fighting, and other domains. This presentation will discuss confidential, voluntary, and non-punitive reporting systems and their advantages in providing information for safety improvements.

  9. Positioning e-skills within an organisation: An information systems management viewpoint

    Directory of Open Access Journals (Sweden)

    Zoran Mitrovic

    2010-10-01

    Full Text Available The intersection of business and IT in an organisation requires people with diverse business- and technology-related competences and skills, commonly referred to as ‘e-competences’ and ‘e-skills’. The positioning of these competences within an IT function in an organisation is (arguably well defined, but their place in other areas of business managerial concern in an organisation, such as business processes or organisational strategy, is still not sufficiently clear. As e-skills and e-competences are inevitably associated with the use of organisational information systems (IS, this paper reports an initial study aimed at positioning these competences and skills within an organisation from an IS perspective. The positioning was done by examining models of IS, e-competences and e-skills and identifying their possible areas of intersection, which resulted in mapping these competences and skills to the areas of managerial concern in an organisation – as seen from an IS perspective. This mapping has revealed an initial understanding of how business value, here seen as business benefits, is created by using the e-skills and e-competences (supposedly possessed by employees throughout an organisation.

  10. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  11. Transplantation of infant kidneys - the surgical technique en bloc and transplant position variation: A case report

    Directory of Open Access Journals (Sweden)

    Popović Vladan

    2015-01-01

    Full Text Available Introduction. Due to the ever-present lack of kidney transplant grafts, more and more organs obtained from the so-called “marginal donors” group are accepted, which can provide suboptimal effect of transplantation, depending on their characteristics and/or implantation techniques. Case report. We presented a case with successful variation of kidney position with modified approach of kidney transplantation from an infant to an adult female patient with normal postoperative recovery. Urethral anastomosis was performed without antireflux procedure and this has not led to the development of reflux disease at an early stage. Conclusion. The position of a pair of kidneys proved to be satisfactory despite the growth of the kidney to the expected size and relatively small pelvis. There were no problems with venous stasis and kidney function from the very beginning was good.

  12. Consumer response to a report card comparing healthcare systems.

    Science.gov (United States)

    Braun, Barbara L; Kind, Elizabeth A; Fowles, Jinnet B; Suarez, Walter G

    2002-06-01

    Report cards to date have focused on quality of care in health plans rather than within healthcare delivery systems. The purpose of this study was to evaluate consumer response to the first healthcare system-level report card. Qualitative assessment of consumer response. We conducted 5 focus groups of community members to evaluate consumer response to the report card; 2 included community club members, 3 included community-dwelling retired persons. Discussions were audiotaped and transcribed; comments were categorized by topic area from the script, and common themes identified. Focus group participants, in general, were unaware of the current emphasis on medical quality improvement initiatives. However, they believed that the opinion that the descriptive clinic information and patient survey data contained in the report card would be most useful mainly for choosing a healthcare system if they were dissatisfied with current medical care, if their healthcare options changed, or if they were in poor health. Personal experience was considered a more trustworthy measure of healthcare quality than were patient survey results. Trustworthiness was perceived to be higher if the report card sponsor was not affiliated with the healthcare systems being evaluated. Participants also believed care system administrators should use the data to enact positive clinic-level and physician-level changes. Healthcare consumers appreciated the attention to patient experiences and supported healthcare quality improvement initiatives. Report cards were considered important for choosing a healthcare system in certain circumstances and for guiding quality improvement efforts at all levels.

  13. UNITED STATES DEPARTMENT OF TRANSPORTATION GLOBAL POSITIONING SYSTEM (GPS) ADJACENT BAND COMPATIBILITY ASSESSMENT

    Science.gov (United States)

    2018-04-01

    The goal of the U.S. Department of Transportation (DOT) Global Positioning System (GPS) Adjacent Band Compatibility Assessment is to evaluate the maximum transmitted power levels of adjacent band radiofrequency (RF) systems that can be tolerated by G...

  14. Systematic Review of Studies Reporting Positive Surgical Margins After Bladder Neck Sparing Radical Prostatectomy.

    Science.gov (United States)

    Bellangino, Mariangela; Verrill, Clare; Leslie, Tom; Bell, Richard W; Hamdy, Freddie C; Lamb, Alastair D

    2017-11-07

    Bladder neck preservation (BNP) during radical prostatectomy (RP) has been proposed as a method to improve early recovery of urinary continence after radical prostatectomy. However, there is concern over a possible increase in the risk of positive surgical margins and prostate cancer recurrence rate. A recent systematic review and meta-analysis reported improved early recovery and overall long-term urinary continence without compromising oncologic control. The aim of our study was to perform a critical review of the literature to assess the impact on bladder neck and base margins after bladder neck sparing radical prostatectomy. We carried out a systematic review of the literature using Pubmed, Scopus and Cochrane library databases in May 2017 using medical subject headings and free-text protocol according to PRISMA guidelines. We used the following search terms: bladder neck preservation, prostate cancer, radical prostatectomy and surgical margins. Studies focusing on positive surgical margins (PSM) in bladder neck sparing RP pertinent to the objective of this review were included. Overall, we found 15 relevant studies reporting overall and site-specific positive surgical margins rate after bladder neck sparing radical prostatectomy. This included two RCTs, seven prospective comparative studies, two retrospective comparative studies and four case series. All studies were published between 1993 and 2015 with sample sizes ranging between 50 and 1067. Surgical approaches included open, laparoscopic and robot-assisted radical prostatectomy. The overall and base-specific PSM rates ranged between 7-36% and 0-16.3%, respectively. Mean base PSM was 4.9% in those patients where bladder neck sparing was performed, but only 1.85% in those without sparing. Bladder neck preservation during radical prostatectomy may increase base-positive margins. Further studies are needed to better investigate the impact of this technique on oncological outcomes. A future paradigm could

  15. Operating experience feedback report - Air systems problems

    International Nuclear Information System (INIS)

    Ornstein, H.L.

    1987-12-01

    This report highlights significant operating events involving observed or potential failures of safety-related systems in U.S. plants that resulted from degraded or malfunctioning non-safety grade air systems. Based upon the evaluation of these events, the Office for Analysis and Evaluation of Operational Data (AEOD) concludes that the issue of air systems problems is an important one which requires additional NRC and industry attention. This report also provides AEOD's recommendations for corrective actions to deal with the issue. (author)

  16. Problem reporting management system performance simulation

    Science.gov (United States)

    Vannatta, David S.

    1993-01-01

    This paper proposes the Problem Reporting Management System (PRMS) model as an effective discrete simulation tool that determines the risks involved during the development phase of a Trouble Tracking Reporting Data Base replacement system. The model considers the type of equipment and networks which will be used in the replacement system as well as varying user loads, size of the database, and expected operational availability. The paper discusses the dynamics, stability, and application of the PRMS and addresses suggested concepts to enhance the service performance and enrich them.

  17. Preoperational test report, recirculation ventilation systems

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  18. Preoperational test report, recirculation ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  19. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  20. Apollo experience report: Earth landing system

    Science.gov (United States)

    West, R. B.

    1973-01-01

    A brief discussion of the development of the Apollo earth landing system and a functional description of the system are presented in this report. The more significant problems that were encountered during the program, the solutions, and, in general, the knowledge that was gained are discussed in detail. Two appendixes presenting a detailed description of the various system components and a summary of the development and the qualification test programs are included.

  1. Changing Social and Environmental Reporting Systems

    DEFF Research Database (Denmark)

    Kaspersen, Mia; Riise Johansen, Thomas

    2016-01-01

    Based on a case study of a large multinational group, this paper addresses the way in which social and environmental reporting (SER) systems were changed and the consequences and controversies associated with this change. Drawing on Power's work on the processes by which things are made auditable...... via underlying systems, we focus on how and why a specific programme with auditability as its ultimate aim changed the basis on which the external social and environmental report was prepared. Our analysis demonstrates that the perceived alignment with the financial report preparation and the explicit...... pursuit of auditability legitimized SER and paved the way for data systems to be changed. The programme borrowed authority from financial accounting technologies not only to make a system change but also to push SER internally, as we suggest that an intraorganizational group used the programme to ensure...

  2. A beam position monitor system for electron cooler in HIRFL-CSR

    International Nuclear Information System (INIS)

    Li Guohong; Li Jie; Yang Xiaodong; Yan Tailai; Ma Xiaoming

    2010-01-01

    The efficient electron cooling requires that the ion beam and electron beam are parallel and overlapped. In order to measure the positions of ion beam and electron beam simultaneously, a beam position monitor system is developed for the HIRFL-CSR electron cooler device, which probe consists of four capacitive cylinder linear-cut poles. One can get the both beam positions from the picking up signals of four poles by using Fourier transform (FFT) method. The measurement results show that the beam position monitor system is accurate. This system is suitable for investigating the relation between electron cooling processing and the angle of ion beam and electron beam. (authors)

  3. Physical Demands of Top-Class Soccer Friendly Matches in Relation to a Playing Position Using Global Positioning System Technology.

    Science.gov (United States)

    Mallo, Javier; Mena, Esteban; Nevado, Fabio; Paredes, Víctor

    2015-09-29

    The aim of this study was to examine the physical demands imposed on professional soccer players during 11-a-side friendly matches in relation to their playing position, using global positioning system (GPS) technology. One hundred and eleven match performances of a Spanish "La Liga" team during the 2010-11 and 2011-12 pre-seasons were selected for analysis. The activities of the players were monitored using GPS technology with a sampling frequency of 1 Hz. Total distance covered, distance in different speed categories, accelerations, and heart rate responses were analyzed in relation to five different playing positions: central defenders (n=23), full-backs (n=20), central midfielders (n=22), wide midfielders (n=26), and forwards (n=20). Distance covered during a match averaged 10.8 km, with wide and central midfielders covering the greatest total distance. Specifically, wide midfielders covered the greatest distances by very high-intensity running (>19.8 km·h-1) and central midfielders by jogging and running (7.2-19.7 km·h-1). On the other hand, central defenders covered the least total distance and at high intensity, although carried out more (pwork rate profile of the players obtained with the GPS was very similar to that obtained with semi-automatic image technologies. However, when comparing results from this study with data available in the literature, important differences were detected in the amount of distance covered by sprinting, which suggests that caution should be taken when comparing data obtained with the GPS with other motion analysis systems, especially regarding high-intensity activities.

  4. Physical Demands of Top-Class Soccer Friendly Matches in Relation to a Playing Position Using Global Positioning System Technology

    Directory of Open Access Journals (Sweden)

    Mallo Javier

    2015-09-01

    Full Text Available The aim of this study was to examine the physical demands imposed on professional soccer players during 11-a-side friendly matches in relation to their playing position, using global positioning system (GPS technology. One hundred and eleven match performances of a Spanish “La Liga” team during the 2010-11 and 2011-12 pre-seasons were selected for analysis. The activities of the players were monitored using GPS technology with a sampling frequency of 1 Hz. Total distance covered, distance in different speed categories, accelerations, and heart rate responses were analyzed in relation to five different playing positions: central defenders (n=23, full-backs (n=20, central midfielders (n=22, wide midfielders (n=26, and forwards (n=20. Distance covered during a match averaged 10.8 km, with wide and central midfielders covering the greatest total distance. Specifically, wide midfielders covered the greatest distances by very high-intensity running (>19.8 km·h-1 and central midfielders by jogging and running (7.2-19.7 km·h-1. On the other hand, central defenders covered the least total distance and at high intensity, although carried out more (p<0.05-0.01 accelerations than forwards, wide midfielders, and fullbacks. The work rate profile of the players obtained with the GPS was very similar to that obtained with semi-automatic image technologies. However, when comparing results from this study with data available in the literature, important differences were detected in the amount of distance covered by sprinting, which suggests that caution should be taken when comparing data obtained with the GPS with other motion analysis systems, especially regarding high-intensity activities.

  5. Unerupted Primary Molar Teeth Positioned Inferior to the Permanent Premolar: A Case Report

    Directory of Open Access Journals (Sweden)

    A. Bagheri

    2012-01-01

    Full Text Available Primary tooth impaction is a rare finding during the development of primary dentition. Several factors contribute to the impaction of a deciduous tooth. This report describes the diagnosis and treatment of a 10-year-old boy who presented an impacted second primary mandibular molar. This tooth, located inferior to the second premolar together with an odontoma, was positioned superior to the premolar teeth. Treatment consisted of surgical removal of the impacted deciduoustooth and odontoma and placement of a passive lower lingual holdingarch. Periodic examination was indicated for follow- up. Early intervention was recommended to manage orofacial disfigurement and to avoid consequent problems.

  6. Self-reported oral and general health in relation to socioeconomic position

    OpenAIRE

    Hakeberg, Magnus; Wide Boman, Ulla

    2017-01-01

    Abstract Background During the past two decades, several scientific publications from different countries have shown how oral health in the population varies with social determinants. The aim of the present study was to explore the relationship between self-reported oral and general health in relation to different measures of socioeconomic position. Methods Data were collected from a randomly selected sample of the adult population in Sweden (n = 3500, mean age 53.4 years, 53.1% women). The r...

  7. The Global Positioning System and Its Integration into College Geography Curricula.

    Science.gov (United States)

    Wikle, Thomas A.; Lambert, Dean P.

    1996-01-01

    Introduces global positioning system (GPS) technology to nonspecialist geographers and recommends a framework for implementing GPS instructional modules in college geography courses. GPS was developed as a worldwide satellite-based system by the U.S. Department of Defense to simplify and improve military and civilian navigation and positioning.…

  8. The Global Positioning System--Direction for the Future [and] GPS Technology and Agriculture.

    Science.gov (United States)

    Edmondson, Paul R.; Ginsburg, Alan

    1996-01-01

    Edmondson introduces a satellite-based radio navigation, positioning, and timing system that can be integrated into a variety of curriculum areas. Ginsburg describes how the global positioning system brings far-reaching benefits for crop growers and the environment. (Author)

  9. 75 FR 14658 - Invitation for Public Comment on Mitigation Options for Global Positioning System Satellite...

    Science.gov (United States)

    2010-03-26

    ... Public Comment on Mitigation Options for Global Positioning System Satellite Vehicle Number 49 AGENCY... options prior to changing the health status of Global Positioning System (GPS) satellite IIR-20M (satellite vehicle number 49--SVN 49) from unhealthy to healthy. The potential mitigations are each designed...

  10. Increasing the bit rate in OCDMA systems using pulse position modulation techniques.

    Science.gov (United States)

    Arbab, Vahid R; Saghari, Poorya; Haghi, Mahta; Ebrahimi, Paniz; Willner, Alan E

    2007-09-17

    We have experimentally demonstrated two novel pulse position modulation techniques, namely Double Pulse Position Modulation (2-PPM) and Differential Pulse Position Modulation (DPPM) in Time-Wavelength OCDMA systems that will operate at a higher bit rate compared to traditional OOK-OCDMA systems with the same bandwidth. With 2-PPM technique, the number of active users will be more than DPPM while their bit rate is almost the same. Both techniques provide variable quality of service in OCDMA networks.

  11. A customizable, scalable scheduling and reporting system.

    Science.gov (United States)

    Wood, Jody L; Whitman, Beverly J; Mackley, Lisa A; Armstrong, Robert; Shotto, Robert T

    2014-06-01

    Scheduling is essential for running a facility smoothly and for summarizing activities in use reports. The Penn State Hershey Clinical Simulation Center has developed a scheduling interface that uses off-the-shelf components, with customizations that adapt to each institution's data collection and reporting needs. The system is designed using programs within the Microsoft Office 2010 suite. Outlook provides the scheduling component, while the reporting is performed using Access or Excel. An account with a calendar is created for the main schedule, with separate resource accounts created for each room within the center. The Outlook appointment form's 2 default tabs are used, in addition to a customized third tab. The data are then copied from the calendar into either a database table or a spreadsheet, where the reports are generated.Incorporating this system into an institution-wide structure allows integration of personnel lists and potentially enables all users to check the schedule from their desktop. Outlook also has a Web-based application for viewing the basic schedule from outside the institution, although customized data cannot be accessed. The scheduling and reporting functions have been used for a year at the Penn State Hershey Clinical Simulation Center. The schedule has increased workflow efficiency, improved the quality of recorded information, and provided more accurate reporting. The Penn State Hershey Clinical Simulation Center's scheduling and reporting system can be adapted easily to most simulation centers and can expand and change to meet future growth with little or no expense to the center.

  12. Objective-lens-free Fiber-based Position Detection with Nanometer Resolution in a Fiber Optical Trapping System.

    Science.gov (United States)

    Ti, Chaoyang; Ho-Thanh, Minh-Tri; Wen, Qi; Liu, Yuxiang

    2017-10-13

    Position detection with high accuracy is crucial for force calibration of optical trapping systems. Most existing position detection methods require high-numerical-aperture objective lenses, which are bulky, expensive, and difficult to miniaturize. Here, we report an affordable objective-lens-free, fiber-based position detection scheme with 2 nm spatial resolution and 150 MHz bandwidth. This fiber based detection mechanism enables simultaneous trapping and force measurements in a compact fiber optical tweezers system. In addition, we achieved more reliable signal acquisition with less distortion compared with objective based position detection methods, thanks to the light guiding in optical fibers and small distance between the fiber tips and trapped particle. As a demonstration of the fiber based detection, we used the fiber optical tweezers to apply a force on a cell membrane and simultaneously measure the cellular response.

  13. Orofacial manifestations of histoplasmosis in HIV-positive patients: a case report.

    Science.gov (United States)

    Gomes Ferreira, O; Vieira Fernandes, A; Sebastião Borges, A; Simão Ferreira, M; Mota Loyola, A

    2001-01-01

    Amongst the main opportunistic diseases that affect the HIV-positive patient, histoplasmosis is found. This systemic mycosis caused by the fungus Histoplasma capsulatum has the capacity to disseminate from the lung to the skin and oral mucosa. Oral lesions of histoplasmosis can be found with ulcerated or nodular aspect, being always very painful and infiltrating the mucosa. When they are present in the mouth, they strongly indicate the presence of some kind of immunosuppression. This study shows the disease's evolution in an HIV-positive patient, who presented several ulcerated lesions in the oral cavity and facial skin. The symptomatology and clinical aspects of the lesions were not specific for the disease, and due to this, the diagnosis was obtained by cytological smear and oral biopsy. The results of the exams defined the disseminated picture of the infection. The treatment plan involved the use of amphotericin B for the lesions' remission, and, following this, itraconazole was administered in the maintenance phase.

  14. Sleeping position and reported night-time asthma symptoms and medication.

    Science.gov (United States)

    Kalolella, Admirabilis Beno

    2016-01-01

    A 49 years old man, known case of bronchial asthma for 43 years, with history of frequent asthmatic attacks, usually responding to double dose of intravenous Aminophylline and double dose of Hydrocortisone was received at medical emergency care unit at midnight with night-time asthma attack. The attack did not settle with Aminophylline single Intravenous injection. He was then admitted and put in supine sleep position for re-evaluation while his asthma symptoms were monitored while waiting for the medical officer's evaluation of his asthma status. After 3 hours of observation, asthma symptoms were relieved, and patient was discharged home and advised to sleep in supine position throughout every night to prevent asthma symptoms. The patient was followed up through nighttime sleep diary for one month. After one month period of monitoring, the patient had significance reduction in asthma symptoms and reduced night time medication, reduced episodes of night awakening due to asthma symptoms, and improved capability for normal works. This case report describes a novel approach of management and prophylaxis of asthmatic episodes through sleeping position that reduces and control asthma symptoms resulting in reduced drug consumption.

  15. Vibratory response of a mirror support/positioning system for the Advanced Photon Source project at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Basdogan, I.; Shu, Deming; Kuzay, T.M.; Royston, T.J.; Shabana, A.A.

    1996-01-01

    The vibratory response of a typical mirror support/positioning system used at the experimental station of the Advanced Photon Source (APS) project at Argonne National Laboratory is investigated. Positioning precision and stability are especially critical when the supported mirror directs a high-intensity beam aimed at a distant target. Stability may be compromised by low level, low frequency seismic and facility-originated vibrations traveling through the ground and/or vibrations caused by flow-structure interactions in the mirror cooling system. The example case system has five positioning degrees of freedom through the use of precision actuators and rotary and linear bearings. These linkage devices result in complex, multi-dimensional vibratory behavior that is a function of the range of positioning configurations. A rigorous multibody dynamical approach is used for the development of the system equations. Initial results of the study, including estimates of natural frequencies and mode shapes, as well as limited parametric design studies, are presented. While the results reported here are for a particular system, the developed vibratory analysis approach is applicable to the wide range of high-precision optical positioning systems encountered at the APS and at other comparable facilities

  16. A beam position feedback system for beam lines at the photon factory

    International Nuclear Information System (INIS)

    Katsura, T.; Kamiya, Y.; Haga, K.; Mitsuhashi, T.

    1987-01-01

    The beam position of the synchrotron radiation produced from the Storage Ring was stabilized by a twofold position feedback system. A digital feedback system was developed to suppress the diurnal beam movement (one cycle of sin-like drifting motion per day) which became a serious problem in low-emittance operation. The feedback was applied to the closed-orbit-distortion (COD) correction system in order to cancel the position variation at all the beam lines proportionately to the variation monitored at one beam line. An analog feedback system is also used to suppress frequency components faster than the slow diurnal movement

  17. Comparison of CPR1000 and AP1000 rod position indication systems

    International Nuclear Information System (INIS)

    Lei Qing

    2009-01-01

    This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication. (authors)

  18. Systems analysis of stress and positive perceptions in mothers and fathers of pre-school children with autism.

    Science.gov (United States)

    Hastings, Richard P; Kovshoff, Hanna; Ward, Nicholas J; degli Espinosa, Francesca; Brown, Tony; Remington, Bob

    2005-10-01

    Systemic analyses of psychological functioning in families of children with autism have typically shown that parents report different experiences (e.g., stress) and that siblings may also be affected. The purpose of the present research was more explicitly to address relationships between child, partner, and parent variables. Parents of 48 children with autism (41 mother-father pairs) reported on child characteristics, and their own stress and mental health. Mothers were found to report both more depression and more positive perceptions than fathers. Regression analyses revealed that paternal stress and positive perceptions were predicted by maternal depression; maternal stress was predicted by their children's behavior problems (not adaptive behavior or autism symptoms) and by their partner's depression. The future testing of the mechanisms underlying these results is discussed. In addition, the need is emphasized for more systemic analyses to understand the psychological functioning of children with autism and their siblings and parents.

  19. Socio-economic position, family demands and reported health in working men and women.

    Science.gov (United States)

    Regidor, Enrique; Pascual, Cruz; de la Fuente, Luis; Santos, Juana M; Astasio, Paloma; Ortega, Paloma

    2011-02-01

    This study evaluates the extent to which domestic workload explains socio-economic differences in poor self-reported health in women and men. In total, 6284 men and women who were employed and living with a partner were selected from the 2003 Spanish Health Interview Survey. The indicators of family demands investigated were person responsible for housework, number of persons in the household and the presence of at least one child under 15 years of age in the household. The measures of socio-economic position were educational level and household income, and the measures of health status were poor perceived health and limitation of activity due to disease. Household size and presence of a child under 15 in the home were not related with the measures of health status. The indicator about the person who does the housework was related with poor perceived health and with activity limitation. Specifically, the worst health status was seen in respondents who lived in homes where the partner or other family members did the housework. In general, the relation between indicators of socio-economic position and measures of health status was not modified after taking into account the person who does the housework. Among working people with a partner, persons who work and do their own housework do not have poorer perceived health than those living in homes where other people do the housework. This indicator of family demands does not explain the socio-economic differences in self-reported health.

  20. Development of a Hemispherical Metal Diaphragm for Single-Cycle Liquid-Metal Positive Expulsion Systems

    National Research Council Canada - National Science Library

    Gorland, Sol

    1965-01-01

    This report presents experimental results pertaining to the design and development of a metallic expulsion diaphragm for single-cycle positive expulsion of high-temperature liquid in an agravity condition...

  1. Preoperational test report, raw water system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Raw Water System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system supplies makeup water to the W-030 recirculation evaporative cooling towers for tanks AY1O1, AY102, AZ1O1, AZ102. The Raw Water pipe riser and associated strainer and valving is located in the W-030 diesel generator building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  2. Report on analysis of HERBE system

    International Nuclear Information System (INIS)

    1989-07-01

    The objective of this report is the choice of HERBE system configuration and detailed analysis of neutronic characteristics of the chosen configuration. The system is planned to be built at the RB reactor. Neutronic parameters were calculated by computer code VESNA based on transmission probability method using 44 group nuclear data for 28 nuclides. In the first phase, it has been proposed to achieve HERBE system by using fuel elements existing at the RB reactor. It is suggested to build new hybrid system in the RB reactor using new fuel elements that would be produced

  3. Preoperational test report, raw water system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents the preoperational test report for the Raw Water System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system supplies makeup water to the W-030 recirculation evaporative cooling towers for tanks AY1O1, AY102, AZ1O1, AZ102. The Raw Water pipe riser and associated strainer and valving is located in the W-030 diesel generator building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  4. Data acquisition system for linear position sensitive detector based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, A.; Prafulla, S.; Srivastava, V.D.; Mukhopadhyaya, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2003-03-01

    This data acquisition system is developed to serve the requirements of various linear 1PSD based neutron diffractometers. A neutron diffractometer uses a neutron beam as a probe to study the crystallographic properties of materials. Presently two multi-PSD and two single-PSD diffractometers are commissioned and a few more are being installed in Dhruva. This data acquisition system is installed at each of these - diffractometers. Different requirements of individual diffractometers were studied and reconciled to design a single data acquisition system, which can be easily configured or customized for individual setups. The charge division in a linear PSD is converted to a position output with the help of an RDC (Ratio ADC). The ftont-end electronics, which consist of preamplifiers and shaping amplifiers, provide an interface between a PSD and an RDC. A PC add-on card is designed around a Transputer. It can interface 16 RDCs, a few motor controls and on/off controls. Data acquisition and other controls are implemented in the Transputer program. A front-end Windows98 application merges the raw data of different RDCs to obtain the equiangular data. Through software the data acquisition system can be configured for diffetent diffractometers. Commercially available hardware is also integrated as,a part of the data acquisition system in some of the setups. The data acquisition system is working reliably as a part of two single PSD and two multi-PSD diffractometers. It can handle data rates upto 15 K/Sec without any loss of counts. It has played a significant role in providing improved throughput and utilization ofvarious diffractometers. The'data acquisition system and its different applications are presented in this report. (author)

  5. Global Positioning System Use in the Community to Evaluate Improvements in Walking After Revascularization

    Science.gov (United States)

    Gernigon, Marie; Le Faucheur, Alexis; Fradin, Dominique; Noury-Desvaux, Bénédicte; Landron, Cédric; Mahe, Guillaume; Abraham, Pierre

    2015-01-01

    Abstract Revascularization aims at improving walking ability in patients with arterial claudication. The highest measured distance between 2 stops (highest-MDCW), the average walking speed (average-WSCW), and the average stop duration (average-DSCW) can be measured by global positioning system, but their evolution after revascularization is unknown. We included 251 peripheral artery diseased patients with self-reported limiting claudication. The patients performed a 1-hour stroll, recorded by a global positioning system receiver. Patients (n = 172) with confirmed limitation (highest-MDCW the follow-up period were compared with reference patients (ie, with unchanged lifestyle medical or surgical status). Other patients (lost to follow-up or treatment change) were excluded (n = 89). We studied 44 revascularized and 39 reference patients. Changes in highest-MDCW (+442 vs. +13 m) and average-WSCW (+0.3 vs. −0.2 km h−1) were greater in revascularized than in reference patients (both P the groups. Among the revascularized patients, 13 (29.5%) had a change in average-WSCW, but not in highest-MDCW, greater than the mean + 1 standard deviation of the change observed for reference patients. Revascularization may improve highest-MDCW and/or average-WSCW. This first report of changes in community walking ability in revascularized patients suggests that, beyond measuring walking distances, average-WSCW measurement is essential to monitor these changes. Applicability to other surgical populations remains to be evaluated. Registration: http://www.clinicaltrials.gov/ct2/show/NCT01141361 PMID:25950694

  6. Risk analysis of Leksell Gamma Knife Model C with automatic positioning system

    International Nuclear Information System (INIS)

    Goetsch, Steven J.

    2002-01-01

    Purpose: This study was conducted to evaluate the decrease in risk from misadministration of the new Leksell Gamma Knife Model C with Automatic Positioning System compared with previous models. Methods and Materials: Elekta Instruments, A.B. of Stockholm has introduced a new computer-controlled Leksell Gamma Knife Model C which uses motor-driven trunnions to reposition the patient between isocenters (shots) without human intervention. Previous models required the operators to manually set coordinates from a printed list, permitting opportunities for coordinate transposition, incorrect helmet size, incorrect treatment times, missing shots, or repeated shots. Results: A risk analysis was conducted between craniotomy involving hospital admission and outpatient Gamma Knife radiosurgery. A report of the Institute of Medicine of the National Academies dated November 29, 1999 estimated that medical errors kill between 44,000 and 98,000 people each year in the United States. Another report from the National Nosocomial Infections Surveillance System estimates that 2.1 million nosocomial infections occur annually in the United States in acute care hospitals alone, with 31 million total admissions. Conclusions: All medical procedures have attendant risks of morbidity and possibly mortality. Each patient should be counseled as to the risk of adverse effects as well as the likelihood of good results for alternative treatment strategies. This paper seeks to fill a gap in the existing medical literature, which has a paucity of data involving risk estimates for stereotactic radiosurgery

  7. The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements

    Directory of Open Access Journals (Sweden)

    Naus Krzysztof

    2016-08-01

    Full Text Available The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle by the extended Kalman filter (EKF method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy—PNA are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning.

  8. A positioning system for forest diseases and pests based on GIS and PTZ camera

    International Nuclear Information System (INIS)

    Wang, Z B; Zhao, F F; Wang, C B; Wang, L L

    2014-01-01

    Forest diseases and pests cause enormous economic losses and ecological damage every year in China. To prevent and control forest diseases and pests, the key is to get accurate information timely. In order to improve monitoring coverage rate and economize on manpower, a cooperative investigation model for forest diseases and pests is put forward. It is composed of video positioning system and manual labor reconnaissance with mobile GIS embedded in PDA. Video system is used to scan the disaster area, and is particularly effective on where trees are withered. Forest diseases prevention and control workers can check disaster area with PDA system. To support this investigation model, we developed a positioning algorithm and a positioning system. The positioning algorithm is based on DEM and PTZ camera. Moreover, the algorithm accuracy is validated. The software consists of 3D GIS subsystem, 2D GIS subsystem, video control subsystem and disaster positioning subsystem. 3D GIS subsystem makes positioning visual, and practically easy to operate. 2D GIS subsystem can output disaster thematic map. Video control subsystem can change Pan/Tilt/Zoom of a digital camera remotely, to focus on the suspected area. Disaster positioning subsystem implements the positioning algorithm. It is proved that the positioning system can observe forest diseases and pests in practical application for forest departments

  9. The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements.

    Science.gov (United States)

    Krzysztof, Naus; Aleksander, Nowak

    2016-08-15

    The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line) system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy-PNA) are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning.

  10. Methodological Considerations When Quantifying High-Intensity Efforts in Team Sport Using Global Positioning System Technology.

    Science.gov (United States)

    Varley, Matthew C; Jaspers, Arne; Helsen, Werner F; Malone, James J

    2017-09-01

    Sprints and accelerations are popular performance indicators in applied sport. The methods used to define these efforts using athlete-tracking technology could affect the number of efforts reported. This study aimed to determine the influence of different techniques and settings for detecting high-intensity efforts using global positioning system (GPS) data. Velocity and acceleration data from a professional soccer match were recorded via 10-Hz GPS. Velocity data were filtered using either a median or an exponential filter. Acceleration data were derived from velocity data over a 0.2-s time interval (with and without an exponential filter applied) and a 0.3-second time interval. High-speed-running (≥4.17 m/s 2 ), sprint (≥7.00 m/s 2 ), and acceleration (≥2.78 m/s 2 ) efforts were then identified using minimum-effort durations (0.1-0.9 s) to assess differences in the total number of efforts reported. Different velocity-filtering methods resulted in small to moderate differences (effect size [ES] 0.28-1.09) in the number of high-speed-running and sprint efforts detected when minimum duration was GPS. Changes to how high-intensity efforts are defined affect reported data. Therefore, consistency in data processing is advised.

  11. Development of Spreadsheet-Based Integrated Transaction Processing Systems and Financial Reporting Systems

    Science.gov (United States)

    Ariana, I. M.; Bagiada, I. M.

    2018-01-01

    Development of spreadsheet-based integrated transaction processing systems and financial reporting systems is intended to optimize the capabilities of spreadsheet in accounting data processing. The purpose of this study are: 1) to describe the spreadsheet-based integrated transaction processing systems and financial reporting systems; 2) to test its technical and operational feasibility. This study type is research and development. The main steps of study are: 1) needs analysis (need assessment); 2) developing spreadsheet-based integrated transaction processing systems and financial reporting systems; and 3) testing the feasibility of spreadsheet-based integrated transaction processing systems and financial reporting systems. The technical feasibility include the ability of hardware and operating systems to respond the application of accounting, simplicity and ease of use. Operational feasibility include the ability of users using accounting applications, the ability of accounting applications to produce information, and control applications of the accounting applications. The instrument used to assess the technical and operational feasibility of the systems is the expert perception questionnaire. The instrument uses 4 Likert scale, from 1 (strongly disagree) to 4 (strongly agree). Data were analyzed using percentage analysis by comparing the number of answers within one (1) item by the number of ideal answer within one (1) item. Spreadsheet-based integrated transaction processing systems and financial reporting systems integrate sales, purchases, and cash transaction processing systems to produce financial reports (statement of profit or loss and other comprehensive income, statement of changes in equity, statement of financial position, and statement of cash flows) and other reports. Spreadsheet-based integrated transaction processing systems and financial reporting systems is feasible from the technical aspects (87.50%) and operational aspects (84.17%).

  12. [A case of primary central nervous system anaplastic lymphoma kinase positive anaplastic large cell lymphoma manifested as a unilateral pachymeningits].

    Science.gov (United States)

    Fujisawa, Etsuco; Shibayama, Hidehiro; Mitobe, Fumi; Katada, Fumiaki; Sato, Susumu; Fukutake, Toshio

    2017-11-25

    There have been 23 reports of primary central nervous system anaplastic lymphoma kinase (ALK)-positive anaplastic large cell lymphoma in the literature. Here we report the 24th case of a 40-year-old man who presented with occipital headache for one month. His contrast-enhanced brain MRI showed enhancement around the right temporal lobe, which suggested a diagnosis of hypertrophic pachymeningitis. He improved with steroid therapy. After discharge, however, he was readmitted with generalized convulsive seizures. Finally, he was diagnosed as primary central nervous system ALK-positive anaplastic large cell lymphoma by brain biopsy. Primary central nervous system lymphoma invading dura matter can rarely manifests as a unilateral pachymeningitis. Therefore, in case of pachymeningitis, we should pay attention to the possibility of infiltration of lymophoma with meticulous clinical follow-up.

  13. Hydrostatic control system for the height position of the JINR synchrotron

    International Nuclear Information System (INIS)

    Vasyutinskij, I.Yu.; Zinov'ev, L.P.; Karpov, I.I.

    1978-01-01

    Hydrostatic system with remote read-out is created for a more operative control of height position of synchrocyclotrone electromagnet. 3 hydrostatic heads with electrocontact registration of liquid level position were mounted on every electromagnet quadrant. The heads are placed under the magnet in centers of survey channel of the foundation and are switched on in series. Teh schemes of the main system units are given. The order of assembling and adjustment of hydrostatic system elements of the accelerator is described

  14. Individual Public Transportation Accessibility is Positively Associated with Self-Reported Active Commuting.

    Science.gov (United States)

    Djurhuus, Sune; Hansen, Henning Sten; Aadahl, Mette; Glümer, Charlotte

    2014-01-01

    Active commuters have lower risk of chronic disease. Understanding which of the, to some extent, modifiable characteristics of public transportation that facilitate its use is thus important in a public health perspective. The aim of the study was to examine the association between individual public transportation accessibility and self-reported active commuting, and whether the associations varied with commute distance, age, and gender. Twenty-eight thousand nine hundred twenty-eight commuters in The Capital Region of Denmark reported self-reported time spent either walking or cycling to work or study each day and the distance to work or study. Data were obtained from the Danish National Health Survey collected in February to April 2010. Individual accessibility by public transportation was calculated using a multi-modal network in a GIS. Multilevel logistic regression was used to analyze the association between accessibility, expressed as access area, and being an active commuter. Public transport accessibility area based on all stops within walking and cycling distance was positively associated with being an active commuter. Distance to work, age, and gender modified the associations. Residing within 10 km commute distance and in areas of high accessibility was associated with being an active commuter and meeting the recommendations of physical activity. For the respondents above 29 years, individual public transportation accessibility was positively associated with being an active commuter. Women having high accessibility had significantly higher odds of being an active commuter compared to having a low accessibility. For men, the associations were insignificant. This study extends the knowledge about the driving forces of using public transportation for commuting by examining the individual public transportation accessibility. Findings suggest that transportation accessibility supports active commuting and planning of improved public transit accessibility

  15. Multiple positive solutions to a coupled systems of nonlinear fractional differential equations.

    Science.gov (United States)

    Shah, Kamal; Khan, Rahmat Ali

    2016-01-01

    In this article, we study existence, uniqueness and nonexistence of positive solution to a highly nonlinear coupled system of fractional order differential equations. Necessary and sufficient conditions for the existence and uniqueness of positive solution are developed by using Perov's fixed point theorem for the considered problem. Further, we also established sufficient conditions for existence of multiplicity results for positive solutions. Also, we developed some conditions under which the considered coupled system of fractional order differential equations has no positive solution. Appropriate examples are also provided which demonstrate our results.

  16. Analysis of Hybrid Hydrogen Systems: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Dean, J.; Braun, R.; Munoz, D.; Penev, M.; Kinchin, C.

    2010-01-01

    Report on biomass pathways for hydrogen production and how they can be hybridized to support renewable electricity generation. Two hybrid systems were studied in detail for process feasibility and economic performance. The best-performing system was estimated to produce hydrogen at costs ($1.67/kg) within Department of Energy targets ($2.10/kg) for central biomass-derived hydrogen production while also providing value-added energy services to the electric grid.

  17. Global positioning systems (GPS) and microtechnology sensors in team sports: a systematic review.

    Science.gov (United States)

    Cummins, Cloe; Orr, Rhonda; O'Connor, Helen; West, Cameron

    2013-10-01

    Use of Global positioning system (GPS) technology in team sport permits measurement of player position, velocity, and movement patterns. GPS provides scope for better understanding of the specific and positional physiological demands of team sport and can be used to design training programs that adequately prepare athletes for competition with the aim of optimizing on-field performance. The objective of this study was to conduct a systematic review of the depth and scope of reported GPS and microtechnology measures used within individual sports in order to present the contemporary and emerging themes of GPS application within team sports. A systematic review of the application of GPS technology in team sports was conducted. We systematically searched electronic databases from earliest record to June 2012. Permutations of key words included GPS; male and female; age 12-50 years; able-bodied; and recreational to elite competitive team sports. The 35 manuscripts meeting the eligibility criteria included 1,276 participants (age 11.2-31.5 years; 95 % males; 53.8 % elite adult athletes). The majority of manuscripts reported on GPS use in various football codes: Australian football league (AFL; n = 8), soccer (n = 7), rugby union (n = 6), and rugby league (n = 6), with limited representation in other team sports: cricket (n = 3), hockey (n = 3), lacrosse (n = 1), and netball (n = 1). Of the included manuscripts, 34 (97 %) detailed work rate patterns such as distance, relative distance, speed, and accelerations, with only five (14.3 %) reporting on impact variables. Activity profiles characterizing positional play and competitive levels were also described. Work rate patterns were typically categorized into six speed zones, ranging from 0 to 36.0 km·h⁻¹, with descriptors ranging from walking to sprinting used to identify the type of activity mainly performed in each zone. With the exception of cricket, no standardized speed zones or definitions were observed within or

  18. Plan of Time Management of Satellite Positioning System using Quasi-zenith Satellite

    Science.gov (United States)

    Takahashi, Yasuhiro; Fujieda, Miho; Amagai, Jun; Yokota, Shoichiro; Kimura, Kazuhiro; Ito, Hiroyuki; Hama, Shin'ichi; Morikawa, Takao; Kawano, Isao; Kogure, Satoshi

    The Quasi-Zenith satellites System (QZSS) is developed as an integrated satellite service system of communication, broadcasting and positioning for mobile users in specified regions of Japan from high elevation angle. Purposes of the satellite positioning system using Quasi-Zenith satellite (QZS) are to complement and augment the GPS. The national institutes concerned have been developing the positioning system using QZS since 2003 and will carry out experiments and researches in three years after the launch. In this system, National Institute of Information and Communications Technology (NICT) is mainly in charge of timing system for the satellite positioning system using QZS, such as onboard hydrogen maser atomic clock and precise time management system of the QZSS. We started to develop the engineering model of the time management system for the QZSS. The time management system for the QZSS will be used to compare time differences between QZS and earth station as well as to compare between three onboard atomic clocks. This paper introduces time management of satellite positioning system using the QZSS.

  19. LumiCal alignment system - Status report

    CERN Document Server

    Daniluk, W.; Lesiak, T.; Moszczyński, A.; Pawlik, B.; Wojtoń, T.; Zawiejski, L.

    2015-01-01

    The paper describes the status of the laser-based alignment-system for the luminosity detector, LumiCal, taking into considerations the conditions of the International Large Detector in the International Linear Collider project. The design of the system comprises two parts: the first one containing semi-transparent silicon sensors used to deliver simultaneous position measurements in the X,Y directions of the monitored object, and the second one in which the interferometric technique, i.e. the Frequency Scanning Interferometry (FSI), is proposed. Two laboratory prototypes for both components of the system were built and the preliminary measurements of the DUT displacements demonstrated their utility in the design of the final alignment system. The alignment of the LumiCal detector will allow us to monitor the detector displacements and possible deformations in its internal structure. Lack of information of the displacements will introduce a systematic effect which will have an impact on the accuracy of the fi...

  20. Travel patterns during pregnancy: comparison between Global Positioning System (GPS) tracking and questionnaire data.

    Science.gov (United States)

    Wu, Jun; Jiang, Chengsheng; Jaimes, Guillermo; Bartell, Scott; Dang, Andy; Baker, Dean; Delfino, Ralph J

    2013-10-09

    Maternal exposures to traffic-related air pollution have been associated with adverse pregnancy outcomes. Exposures to traffic-related air pollutants are strongly influenced by time spent near traffic. However, little is known about women's travel activities during pregnancy and whether questionnaire-based data can provide reliable information on travel patterns during pregnancy. Examine women's in-vehicle travel behavior during pregnancy and examine the difference in travel data collected by questionnaire and global positioning system (GPS) and their potential for exposure error. We measured work-related travel patterns in 56 pregnant women using a questionnaire and one-week GPS tracking three times during pregnancy (30 weeks of gestation). We compared self-reported activities with GPS-derived trip distance and duration, and examined potentially influential factors that may contribute to differences. We also described in-vehicle travel behavior by pregnancy periods and influences of demographic and personal factors on daily travel times. Finally, we estimated personal exposure to particle-bound polycyclic aromatic hydrocarbon (PB-PAH) and examined the magnitude of exposure misclassification using self-reported vs. GPS travel data. Subjects overestimated both trip duration and trip distance compared to the GPS data. We observed moderately high correlations between self-reported and GPS-recorded travel distance (home to work trips: r = 0.88; work to home trips: r = 0.80). Better agreement was observed between the GPS and the self-reported travel time for home to work trips (r = 0.77) than work to home trips (r = 0.64). The subjects on average spent 69 and 93 minutes traveling in vehicles daily based on the GPS and self-reported data, respectively. Longer daily travel time was observed among participants in early pregnancy, and during certain pregnancy periods in women with higher education attainment, higher income, and no children. When comparing

  1. High angle of attack position sensing for the Southampton University magnetic suspension and balance system

    Science.gov (United States)

    Parker, David H.

    1987-01-01

    An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

  2. Isolated systems with wind power. Main report

    Energy Technology Data Exchange (ETDEWEB)

    Lundsager, P.; Bindner, H.; Clausen, N.E.; Frandsen, S.; Hansen, L.H.; Hansen, J.C.

    2001-06-01

    The overall objective of this research project is to study the development of methods and guidelines rather than 'universal solutions' for the use of wind energy in isolated communities. The main specific objective of the project is to develop and present a more unified and generally applicable approach for assessing the technical and economical feasibility of isolated power supply systems with wind energy. As a part of the project the following tasks were carried out: Review of literature, field measurements in Egypt, development of an inventory of small isolated systems, overview of end-user demands, analysis of findings and development of proposed guidelines. The project is reported in one main report and four topical reports, all of them issued as Risoe reports. This is the Main Report Risoe-R-1256, summing up the activities and findings of the project and outlining an Implementation Strategy for Isolated Systems with Wind Power, applicable for international organisations such as donor agencies and development banks. (au)

  3. Acceptance test report: Backup power system

    International Nuclear Information System (INIS)

    Cole, D.B.

    1996-01-01

    Acceptance Test Report for construction functional testing of Project W-030 Backup Power System. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. Backup power includes a single 125 KW diesel generator, three 10-kva uninterruptible power supply units, and all necessary control

  4. Energy Innovation Systems Indicator Report 2016

    DEFF Research Database (Denmark)

    Borup, Mads; Klitkou, Antje; Iversen, Eric

    This report collates a set of indicators, figures and tables for the energy innovation system in Denmark. Emphasis is on renewable energy and other technologies for moving towards sustainability. The purpose is to provide an overview of indicators available for illuminating dynamics and character...... in “EIS – Strategic research alliance for Energy Innovation Systems and their dynamics – Denmark in global competition”. EIS is funded by the Danish Council for Strategic Research (Innovation Fund Denmark) and by the involved research organisations.......This report collates a set of indicators, figures and tables for the energy innovation system in Denmark. Emphasis is on renewable energy and other technologies for moving towards sustainability. The purpose is to provide an overview of indicators available for illuminating dynamics...... and characteristics of energy innovation systems and to the extent possible offer figures of the developments in the individual indicators. The report is an update of a report published in 2012. Graphs and numbers are updated with the most recent data available. The text is updated where needed in connection...

  5. Railcar waste transfer system hydrostatic test report

    International Nuclear Information System (INIS)

    Ellingson, S.D.

    1997-01-01

    This Acceptance Test Report (ATR) documents for record purposes the field results, acceptance, and approvals of the completed acceptance test per HNF-SD-W417-ATP-001, ''Rail car Waste Transfer System Hydrostatic Test''. The test was completed and approved without any problems or exceptions

  6. The NSTX Trouble Reporting System; TOPICAL

    International Nuclear Information System (INIS)

    S. Sengupta; G. Oliaro

    2002-01-01

    An online Trouble Reporting System (TRS) has been introduced at the National Spherical Torus Experiment (NSTX). The TRS is used by NSTX operators to report problems that affect NSTX operations. The purpose of the TRS is to enhance NSTX reliability and maintainability by identifying components, occurrences, and trends that contribute to machine downtime. All NSTX personnel have access to the TRS. The user interface is via a web browser, such as Netscape or Internet Explorer. This web-based feature permits any X-terminal, PC, or MAC access to the TRS. The TRS is based upon a trouble reporting system developed at the DIII-D Tokamak, at General Atomics Technologies. This paper will provide a detailed description of the TRS software architecture, user interface, MS SQL server interface and operational experiences. In addition, sample data from the TRS database will be summarized and presented

  7. BMFT-UPTF densitometer system test report

    International Nuclear Information System (INIS)

    Menkhaus, D.E.

    1985-11-01

    This report documents acceptance test results performed on the five Upper Plenum Test Facility (UPTF) three-beam densitometer systems and spare parts. The five densitometer systems are used on the UPTF four hot legs and broken cold leg to measure average chordal-beam densities. The primary objectives of the tests performed were: to verify all assemblies fit as designed (mechanical fitup); to ensure radiation levels met the criteria (<2.5 mR/h); to verify that design accuracy requirements were met (performance tests); and to verify proper operation of the densitometer systems (functional checks). 15 figs., 11 tabs

  8. Innovative directional and position specific sampling technique. Phase 3: Final report, July 1992--September 1994

    International Nuclear Information System (INIS)

    Hutzel, W.J.; Hill, J.L. III; Foster, E.L.

    1994-09-01

    The POLO System is a major enhancement to the state of the art for subsurface environmental restoration equipment. The system locate s the tip position of penetrometer probes as they are placed underground while meeting the rigid constraints of environmental restoration applications. POLO is applicable to small diameter probes, does not obstruct the center of the probe, is rugged, is unaffected by the presence of steel or other magnetic material, and is capable of remote operation beneath underground tanks or foundations. The development and adaptation of the POLO System for use with penetrometers has progressed through three development phases prior to commercialization. Phases I and II of the contract included the design, testing, and integration of all components of the POLO device. Efforts were made to simulate field conditions in terms of the scale of the components as well as the operating environment. The preestablished success criterion, which has been maintained throughout the research, was to demonstrate path tracking with a total error of less than 0.50% of the distance traveled for distances less than 70 meters. The results tests on individual POLO components showed that the equipment met or exceeded the success criterion. Phase II laboratory scale path tracking experiments also met the success criterion. Phase III moved the POLO System into the field. The full-scale field demonstration tested the ability of the new POLO Module to track the path of a small diameter probe as it moved underground

  9. The Message Reporting System of the ATLAS DAQ System

    CERN Document Server

    Caprini, M; Kolos, S; 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications

    2008-01-01

    The Message Reporting System (MRS) in the ATLAS data acquisition system (DAQ) is one package of the Online Software which acts as a glue of various elements of DAQ, High Level Trigger (HLT) and Detector Control System (DCS). The aim of the MRS is to provide a facility which allows all software components in ATLAS to report messages to other components of the distributed DAQ system. The processes requiring a MRS are on one hand applications that report error conditions or information and on the other hand message processors that receive reported messages. A message reporting application can inject one or more messages into the MRS at any time. An application wishing to receive messages can subscribe to a message group according to defined criteria. The application receives messages that fulfill the subscription criteria when they are reported to MRS. The receiver message processing can consist of anything from simply logging the messages in a file/terminal to performing message analysis. The inter-process comm...

  10. A classification system for plasmids from Enterococci and other Gram-positive bacteria

    DEFF Research Database (Denmark)

    Jensen, Lars Bogø; Garcia-Migura, Lourdes; Valenzuela, Antonio Jesus Sanchez

    2010-01-01

    A classification system for plasmids isolated from enterococci and other Gram-positive bacteria was developed based on 111 published plasmid sequences from enterococci and other Gram-positive bacteria; mostly staphylococci. Based on PCR amplification of conserved areas of the replication initiating....... Furthermore, conjugation experiments were performed obtaining 30 transconjugants when selecting for antimicrobial resistance. Among them 19 gave no positive amplicons indicating presence of rep-families not tested for in this experimental setup....

  11. Study of a new source for positive and negative ions. Final report

    International Nuclear Information System (INIS)

    Freedman, A.; Davidovits, P.

    1985-05-01

    This study has focused on the feasibility of a novel ion source based on the technique of photodissociation, which could provide both positive and negative ions at considerably higher intensities (potentially 10 15 cm -3 ) than are currently available. Ions are produced by irradiating a sample of a gaseous thallium halide salt with an argon fluoride excimer laser operating at 193 nm. At this wavelength, both thallium bromide and iodide will produce atomic ion pairs in a single photon process and molecular positive ions and an electron in a two-photon induced process. The potential traits of such an excimer-laser pumped thallium salt ion source include the following: high intensity and pulse rate, good spatial and temporal resolution, low temperature, good focusing properties, and production of heavy ions. This report describes a Phase I effort investigating the efficacy of this approach. A review of the relevant photophysics pertaining to laser excitation of thallium halide salts is presented, followed by a description of both experimental and theoretical efforts involving thallium bromide in particular. The last section will summarize the basic conclusions derived from these studies, as well as discuss potential advantages of an ion source derived from photolyzing thallium halide salts

  12. Reliability design of the continuous monitoring system software for an position radiation

    International Nuclear Information System (INIS)

    Kang Yuebing; Li Tiantuo; Di Yuming; Zhang Yanhong

    2004-01-01

    The reliability and stabilization is an important technical target for a continuous monitoring system. After analyzing the position's environment and the system's structure, we put forward some methods of the software's reliability design and put these into the application. The practice shows that it is important to improve the system's stability and reliability. (authors)

  13. Space reactor electric systems: system integration studies, Phase 1 report

    International Nuclear Information System (INIS)

    Anderson, R.V.; Bost, D.; Determan, W.R.; Harty, R.B.; Katz, B.; Keshishian, V.; Lillie, A.F.; Thomson, W.B.

    1983-01-01

    This report presents the results of preliminary space reactor electric system integration studies performed by Rockwell International's Energy Systems Group (ESG). The preliminary studies investigated a broad range of reactor electric system concepts for powers of 25 and 100 KWe. The purpose of the studies was to provide timely system information of suitable accuracy to support ongoing mission planning activities. The preliminary system studies were performed by assembling the five different subsystems that are used in a system: the reactor, the shielding, the primary heat transport, the power conversion-processing, and the heat rejection subsystems. The subsystem data in this report were largely based on Rockwell's recently prepared Subsystem Technology Assessment Report. Nine generic types of reactor subsystems were used in these system studies. Several levels of technology were used for each type of reactor subsystem. Seven generic types of power conversion-processing subsystems were used, and several levels of technology were again used for each type. In addition, various types and levels of technology were used for the shielding, primary heat transport, and heat rejection subsystems. A total of 60 systems were studied

  14. Preoperational test report, recirculation condenser cooling systems

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  15. Preoperational test report, recirculation condenser cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  16. A State-of-the-Art Survey of Indoor Positioning and Navigation Systems and Technologies

    Directory of Open Access Journals (Sweden)

    Wilson Sakpere

    2017-12-01

    Full Text Available The research and use of positioning and navigation technologies outdoors has seen a steady and exponential growth. Based on this success, there have been attempts to implement these technologies indoors, leading to numerous studies. Most of the algorithms, techniques and technologies used have been implemented outdoors. However, how they fare indoors is different altogether. Thus, several technologies have been proposed and implemented to improve positioning and navigation indoors. Among them are Infrared (IR, Ultrasound, Audible Sound, Magnetic, Optical and Vision, Radio Frequency (RF, Visible Light, Pedestrian Dead Reckoning (PDR/Inertial Navigation System (INS and Hybrid. The RF technologies include Bluetooth, Ultra-wideband (UWB, Wireless Sensor Network (WSN, Wireless Local Area Network (WLAN, Radio-Frequency Identification (RFID and Near Field Communication (NFC. In addition, positioning techniques applied in indoor positioning systems include the signal properties and positioning algorithms. The prevalent signal properties are Angle of Arrival (AOA, Time of Arrival (TOA, Time Difference of Arrival (TDOA and Received Signal Strength Indication (RSSI, while the positioning algorithms are Triangulation, Trilateration, Proximity and Scene Analysis/ Fingerprinting. This paper presents a state-of-the-art survey of indoor positioning and navigation systems and technologies, and their use in various scenarios. It analyses distinct positioning technology metrics such as accuracy, complexity, cost, privacy, scalability and usability. This paper has profound implications for future studies of positioning and navigation.

  17. Using The Global Positioning System For Earth Orbiter and Deep Space Network

    Science.gov (United States)

    Lichten, Stephen M.; Haines, Bruce J.; Young, Lawrence E.; Dunn, Charles; Srinivasan, Jeff; Sweeney, Dennis; Nandi, Sumita; Spitzmesser, Don

    1994-01-01

    The Global Positioning System (GPS) can play a major role in supporting orbit and trajectory determination for spacecraft in a wide range of applications, including low-Earth, high-earth, and even deep space (interplanetary) tracking.

  18. Ground-Based Global Positioning System (GPS) Meteorology Integrated Precipitable Water Vapor (IPW)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Ground-Based Global Positioning System (GPS) Meteorology Integrated Precipitable Water Vapor (IPW) data set measures atmospheric water vapor using ground-based...

  19. Development of Mission Enabling Infrastructure — Cislunar Autonomous Positioning System (CAPS)

    Science.gov (United States)

    Cheetham, B. W.

    2017-10-01

    Advanced Space, LLC is developing the Cislunar Autonomous Positioning System (CAPS) which would provide a scalable and evolvable architecture for navigation to reduce ground congestion and improve operations for missions throughout cislunar space.

  20. Existence of positive solutions for the system of higher order two ...

    Indian Academy of Sciences (India)

    2Department of Mathematics, Gayatri Vidya Parishad College of Engineering ... In these applied settings, positive solutions are meaningful [1,9,13,21]. Due to ... In this paper, we shall consider the nonlinear system of differential equations,. ⎧.

  1. A new system to quantify uncertainties in LEO satellite position determination due to space weather events

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a new system for quantitative assessment of uncertainties in LEO satellite position caused by storm time changes in space environmental...

  2. MDOT implementation plan for global positioning systems (GPS) technology in planning, design, and construction delivery.

    Science.gov (United States)

    2010-09-13

    Global Positioning System (GPS) technology offers advantages to transportation agencies in the planning, design and construction stages of project delivery. This research study will develop a guide for Mississippi Department of Transportation (MDOT) ...

  3. Hyperchaos of four state autonomous system with three positive Lyapunov exponents

    International Nuclear Information System (INIS)

    Ge Zhengming; Yang, C-H.

    2009-01-01

    This Letter gives the results of numerical simulations of Quantum Cellular Neural Network (Quantum-CNN) autonomous system with four state variables. Three positive Lyapunov exponents confirm hyperchaotic nature of its dynamics

  4. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  5. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  6. Multicentric Castleman's Disease in a Hepatitis C-Positive Intravenous Drug User: A Case Report

    Directory of Open Access Journals (Sweden)

    D. Y. Talukder

    2011-01-01

    Full Text Available Introduction. We report a rare presentation of Castleman's disease in a hepatitis C-positive patient and present a short review of treatments described in other similar case reports and studies. Case Presentation. A 46-year-old male with untreated hepatitis C and a 16-year history of intravenous drug use presented with pleuritic chest pain and bony pain in the knee, hip, and lower back, on a background of unexplained weight loss of 40 kilograms, fevers, night sweats, and repeated infections over the last two years. Examination discovered tender hepatomegaly, a warm right knee effusion, and painless lymphadenopathy. The patient was reactive to Epstein Barr virus and cytomegalovirus; however, HIV and HHV-8 viral testing was negative. Osteomyelitis of vertebrae T8–T11 and septic arthritis of the knee were found on investigation. A lymph node biopsy revealed histology suggestive of plasmacytic Castleman's disease. The patient is to commence rituximab treatment. Conclusion. Castleman's disease continues to present in novel ways, which may lead to difficulties in clinicopathologic diagnosis. A growing body of evidence suggests larger studies are required to determine the best treatment for multicentric Castleman's disease, particularly in patients with a concomitant disease, including hepatitis C.

  7. A Case Report of Positive HTLV-I Infection with Bilateral Facial Weakness and Myelitis

    Directory of Open Access Journals (Sweden)

    M. Mazdeh

    2005-04-01

    Full Text Available Infection with human T cell lymphotropic virus type I (HTLV-I causes multiple neurologic disorder , due to the retroviruses.Spinal cord disease of this type is named TSP (tropical spastic paraparesis that were drawn to the attention of neurologists 45 years ago. The clinical picture is one of the slowly progressive paraparesis with increased tendon reflexes & Babinski signs ; disorder of sphincteric control is usually an early change. Paresthesia , reduced vibratory & position senses, & ataxia have been described. The diagnosis is confirmed by the detection the antibodies to the virus in serum . There are anecdotal reports of improvement with IV-administration of gammaglobulin. But HTLV1-infection has other clinical manifestations. This report presents a rare case with bilateral facial weakness as primary manifestation. This case is related to a 41 years old woman. The clinical picture was bilateral facial weekness and approximately after 2 months, she referred to hospital with myelitis. In primary exams and evaluation, the diagnose was HTLV-I infection. The diagnosis was confirmed by the detection of the antibodies against the virus in her serum. She dead after 2.5 months of the first sign due to disease severity and bulbar palsy. Possible transmission routes and the risk of encountering the disease outside endemic areas must be attended , and it is recommended to evaluate antibodies in the children of the patients.

  8. Adopting the international financial reporting standards: a positive impact on 2004 income and consolidated equity

    International Nuclear Information System (INIS)

    Mallet, O.

    2005-03-01

    This document provides preliminary information on the quantitative impact of transition to the International Financial Reporting Standards (IFRS) on AREVA 2004 financial position, in accordance with AMF recommendations regarding financial communications during the transition period.The basis for preparing 2004 information on transition to the IFRS comes from: the International Accounting Standards (IAS)/IFRS, as approved by the European Union. The impact of IAS 32/39 and IFRS 4 will not be recognized in shareholders equity until January 1, 2005; AREVA anticipation of the resolution of technical issues and ongoing projects under discussion by the International Accounting Standards Board (IASB) and the International Financial Reporting Interpretations Committee (IFRIC). Uncertainty factors on practical methods for applying certain standards and ongoing interpretations by IFRIC and regulatory organizations could impact the exactness of restatements identified at this stage. For all of these reasons, it is conceivable that the opening balance sheet at January 1, 2004, as presented in this document, will not be the balance sheet actually used to establish the consolidated financial statements for 2005. (author)

  9. PRINCIPLES OF REGIONAL COMPLEXES’ POSITIONING IN THE SYSTEM OF SPATIAL DEVELOPMENT

    OpenAIRE

    Головня, Юлія Ігорівна

    2016-01-01

    The article is devoted to the peculiarities of region’s positioning in the system of spatial development. The approaches to the study of this issue in terms of marketing (the area is market’s goods), economics (the area is environment) and social and economic geography (the area is territorial and social system) are analyzed. The attention is paid to the process of positioning which allows to strengthen competitive advantages of the region and to identify strategic priorities of its developme...

  10. Global Positioning Systems (GPS) Technology to Study Vector-Pathogen-Host Interactions

    Science.gov (United States)

    2016-12-01

    Award Number: W81XWH-11-2-0175 TITLE: Global Positioning Systems (GPS) Technology to Study Vector-Pathogen-Host Interactions PRINCIPAL...Positioning Systems (GPS) Technology to Study Vector-Pathogen-Host Interactions 5b. GRANT NUMBER W81XWH-11-2-0175 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...genetic diversity in the population, in hospitalized children with severe dengue illness and cluster investigation of their neighborhoods, and by using

  11. Absence of positive solutions to the system of differential inequalities on manifolds

    Science.gov (United States)

    Sun, Yuhua

    2018-01-01

    We investigate the nonexistence of positive solutions to a certain system of differential inequalities on a complete connected non-compact Riemannian manifold. We show that if for some reference point x0, the volume of geodesic ball μ(B(x0, r)) ≤ Crp ln q r holds for all large enough r and for some constant C, then there exists no positive solution to the system. Here the exponents p and q are sharp and cannot be relaxed.

  12. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    Science.gov (United States)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  13. Fault tolerant, multiplexed control rod position detection and indication system for nuclear power plants

    International Nuclear Information System (INIS)

    Dufek, W.L.; Jelovich, J.J.; Neuner, J.A.

    1977-01-01

    The majority of Westinghouse nuclear plants placed in service thus far have incorporated a Rod Position Indication system based upon an analog design philosophy. This system, while meeting all functional and accuracy requirements, has proven somewhat cumbersome, particularly in the area of initial field calibration and maintenance. This paper describes a new Digital Rod Position Indication system (DRPI) developed for use with pressurized water reactors. The system is based upon a digital design philosophy and meets all previous design constraints and environmental requirements. Further, fault tolerance, improved accuracy, interference from adjacent rods and the elimination of adjustments and calibration has been provided

  14. Equilibrium positions due to different cooling processes in superconducting levitation systems

    International Nuclear Information System (INIS)

    Navau, C; Sanchez, A; Pardo, E; Chen, D-X

    2004-01-01

    The equilibrium position of a superconducting levitation device is determined not only by the geometry and electromagnetic properties of its components, but also by the cooling process of the superconductor. In this work we study the dependence of the equilibrium positions upon the cooling process by introducing diagrams of a new kind which display the different possibilities for a given levitation system. Using the critical state model and the principle of magnetic energy, we calculate different diagrams of this type for the case of a cylindrically symmetric permanent magnet-superconductor system. The results allow us to find out, for a given levitation system, which cooling process improves the capabilities of the system

  15. Received Signal Strength Database Interpolation by Kriging for a Wi-Fi Indoor Positioning System.

    Science.gov (United States)

    Jan, Shau-Shiun; Yeh, Shuo-Ju; Liu, Ya-Wen

    2015-08-28

    The main approach for a Wi-Fi indoor positioning system is based on the received signal strength (RSS) measurements, and the fingerprinting method is utilized to determine the user position by matching the RSS values with the pre-surveyed RSS database. To build a RSS fingerprint database is essential for an RSS based indoor positioning system, and building such a RSS fingerprint database requires lots of time and effort. As the range of the indoor environment becomes larger, labor is increased. To provide better indoor positioning services and to reduce the labor required for the establishment of the positioning system at the same time, an indoor positioning system with an appropriate spatial interpolation method is needed. In addition, the advantage of the RSS approach is that the signal strength decays as the transmission distance increases, and this signal propagation characteristic is applied to an interpolated database with the Kriging algorithm in this paper. Using the distribution of reference points (RPs) at measured points, the signal propagation model of the Wi-Fi access point (AP) in the building can be built and expressed as a function. The function, as the spatial structure of the environment, can create the RSS database quickly in different indoor environments. Thus, in this paper, a Wi-Fi indoor positioning system based on the Kriging fingerprinting method is developed. As shown in the experiment results, with a 72.2% probability, the error of the extended RSS database with Kriging is less than 3 dBm compared to the surveyed RSS database. Importantly, the positioning error of the developed Wi-Fi indoor positioning system with Kriging is reduced by 17.9% in average than that without Kriging.

  16. University of California, San Diego (UCSD) Sky Imager Cloud Position Study Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Kleissl, J. [Univ. of California, San Diego, CA (United States); Urquhart, B. [Univ. of California, San Diego, CA (United States); Ghonima, M. [Univ. of California, San Diego, CA (United States); Dahlin, E. [Univ. of California, San Diego, CA (United States); Nguyen, A. [Univ. of California, San Diego, CA (United States); Kurtz, B. [Univ. of California, San Diego, CA (United States); Chow, C. W. [Univ. of California, San Diego, CA (United States); Mejia, F. A. [Univ. of California, San Diego, CA (United States)

    2016-04-01

    During the University of California, San Diego (UCSD) Sky Imager Cloud Position Study, two University of California, San Diego Sky Imagers (USI) (Figure 1) were deployed the U.S. Department of Energy(DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains SGP) research facility. The UCSD Sky Imagers were placed 1.7 km apart to allow for stereographic determination of the cloud height for clouds over approximately 1.5 km. Images with a 180-degree field of view were captured from both systems during daylight hours every 30 seconds beginning on March 11, 2013 and ending on November 4, 2013. The spatial resolution of the images was 1,748 × 1,748, and the intensity resolution was 16 bits using a high-dynamic-range capture process. The cameras use a fisheye lens, so the images are distorted following an equisolid angle projection.

  17. Energy innovation systems indicator report 2012

    Energy Technology Data Exchange (ETDEWEB)

    Borup, M. [Technical Univ. of Denmark. DTU Management Engineering, Kgs. Lyngby (Denmark); Klitkou, A.; Iversen, E. [Nordic Institute for Studies in Innovation, Research and Education, Oslo (Norway)

    2012-12-15

    Knowledge about the innovation systems with respect to new energy solutions and technologies is of central importance for understanding the dynamics of change in the energy sector and assessment of opportunities for moving towards more climate-friendly and sustainable energy systems and for socio-economic development in the field, creation of new businesses, work places, etc.. This is the topic that in general is addressed in the research activities of the ''EIS - Strategic research alliance for Energy Innovation Systems and their dynamics - Denmark in global competition''. As part of this, the present report gives an overview of the available indicators of energy innovation systems and points out some of the limitations and potentials there currently are in this connection. Focus is on Denmark. Figures for other countries, primarily Nordic or European, are in some cases showed as well, offering a comparative perspective. (Author)

  18. Demonstrating EnTracked a System for Energy-Efficient Position Tracking for Mobile Devices

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Jensen, Jakob Langdal; Godsk, Torben

    An important feature of a modern mobile device is that it can position itself. Not only for use on the device but also for remote applications that require tracking of the device. To be useful, such position tracking has to be energy-efficient to avoid having a major impact on the battery life...... of the mobile device. To address this challenge we have build a system named EnTracked that, based on the estimation and prediction of system conditions and mobility, schedules position updates to both minimize energy consumption and optimize robustness. In this demonstration we would like to show how...

  19. Application of robot kinematics methods to the simulation and control of neutron beam line positioning systems

    Energy Technology Data Exchange (ETDEWEB)

    James, Jonathan A. [Open University, Materials Engineering, Walton Hall, Milton Keynes, Buckinghamshire MK7 6AA (United Kingdom)]. E-mail: j.a.j.james@open.ac.uk; Edwards, Lyndon [Open University, Materials Engineering, Walton Hall, Milton Keynes, Buckinghamshire MK7 6AA (United Kingdom)

    2007-02-11

    Neutron stress measurements require specimens of complex geometry to be speedily and accurately positioned and oriented with respect to the neutron beam. Recognition that a majority of the specimen positioning systems in use at strain scanning facilities are effectively serial robot manipulators, suggests that the methods of serial robot kinematic modelling may be applied to advantage. The adoption of robotics methods provides a simple and reliable framework for controlling positioning systems of arbitrary geometry and complexity. In addition the numerical solution of the inverse kinematic problem is facilitated, allowing specimens to be automatically positioned and orientated so that pre-determined strain components are measured. It is also shown that, given sufficient degrees of freedom, a secondary characteristic of the measurement position such as the measurement count time may be simultaneously optimised.

  20. Critical/non-critical system methodology report

    International Nuclear Information System (INIS)

    1989-01-01

    The method used to determine how the waste Isolation Pilot Plant (WIPP) facilities/systems were classified as critical or non-critical to the receipt of CH waste is described within this report. All WIPP critical facilities/systems are listed in the Operational Readiness Review Dictionary. Using the Final Safety Analysis Report (FSAR) as a guide to define the boundaries of the facilities/systems, a direct correlation of the ORR Dictionary to the FSAR can be obtained. The critical facilities/systems are those which are directly related to or have a critical support role in the receipt of CH waste. The facility/systems must meet one of the following requirements to be considered critical: (a) confinement or measure of the release of radioactive materials; (b) continued receipt and/or storage of transuranic waste (TRU) without an interruption greater than one month according to the shipping plan schedule; (c) the environmental and occupational safety of personnel meets the established site programs; and (d) the physical security of the WIPP facilities

  1. High-precision positioning system of four-quadrant detector based on the database query

    Science.gov (United States)

    Zhang, Xin; Deng, Xiao-guo; Su, Xiu-qin; Zheng, Xiao-qiang

    2015-02-01

    The fine pointing mechanism of the Acquisition, Pointing and Tracking (APT) system in free space laser communication usually use four-quadrant detector (QD) to point and track the laser beam accurately. The positioning precision of QD is one of the key factors of the pointing accuracy to APT system. A positioning system is designed based on FPGA and DSP in this paper, which can realize the sampling of AD, the positioning algorithm and the control of the fast swing mirror. We analyze the positioning error of facular center calculated by universal algorithm when the facular energy obeys Gauss distribution from the working principle of QD. A database is built by calculation and simulation with MatLab software, in which the facular center calculated by universal algorithm is corresponded with the facular center of Gaussian beam, and the database is stored in two pieces of E2PROM as the external memory of DSP. The facular center of Gaussian beam is inquiry in the database on the basis of the facular center calculated by universal algorithm in DSP. The experiment results show that the positioning accuracy of the high-precision positioning system is much better than the positioning accuracy calculated by universal algorithm.

  2. Tehachapi solar thermal system first annual report

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, A. [Southwest Technology Development Inst., Las Cruces, NM (US)

    1993-05-01

    The staff of the Southwest Technology Development Institute (SWTDI), in conjunction with the staff of Industrial Solar Technology (IST), have analyzed the performance, operation, and maintenance of a large solar process heat system in use at the 5,000 inmate California Correctional Institution (CCI) in Tehachapi, CA. This report summarizes the key design features of the solar plant, its construction and maintenance histories through the end of 1991, and the performance data collected at the plant by a dedicated on-site data acquisition system (DAS).

  3. PUREX exhaust ventilation system installation test report

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Report validates the testing performed, the exceptions logged and resolved and certifies this portion of the SAMCONS has met all design and test criteria to perform as an operational system. The proper installation of the PUREX exhaust ventilation system components and wiring was systematically evaluated by performance of this procedure. Proper operation of PUREX exhaust fan inlet, outlet, and vortex damper actuators and limit switches were verified, using special test equipment, to be correct and installed wiring connections were verified by operation of this equipment

  4. Secure stand alone positive personnel identity verification system (SSA-PPIV)

    International Nuclear Information System (INIS)

    Merillat, P.D.

    1979-03-01

    The properties of a secure stand-alone positive personnel identity verification system are detailed. The system is designed to operate without the aid of a central computing facility and the verification function is performed in the absence of security personnel. Security is primarily achieved by means of data encryption on a magnetic stripe badge. Several operational configurations are discussed. Advantages and disadvantages of this system compared to a central computer driven system are detailed

  5. IMPELEMENTASI SISTEM PEMANTAUAN OBJEK BERGERAK DENGAN MEMANFAATKAN FREKUENSI RADIO MENGGUNAKAN GPS (GLOBAL POSITIONING SYSTEM)

    OpenAIRE

    Budi Triandi

    2010-01-01

    GPS was developed by the United States Department of Defense as a reliable means for accurate navigation. The system provides highly accurate position and velocity information and precise time on a continuous global basis to an unlimited number of properly equipped users. By using combined GPS receiver and microcontroller together with radio system, we can design a monitoring system for our vehicles and display the result on the computer. This system consists of a master module that transmits...

  6. A critical incident reporting system in anaesthesia.

    Science.gov (United States)

    Madzimbamuto, F D; Chiware, R

    2001-01-01

    To audit the recently established Critical Incident Reporting System in the Department of Anaesthesia and Critical Care Medicine, University of Zimbabwe Medical School. The system was set up with the purpose of improving the quality of care delivered by the department. Cross sectional study. A critical incident was defined as 'any adverse and reversible event in theatre, during or immediately after surgery that if it persisted without correction would cause harm to the patient'. The anaesthetic or recovery room staff filled a critical incident form anonymously. Data was collected from critical incident reporting forms for analysis. The anaesthetic service in the two teaching hospitals of Harare Central and Parirenyatwa General Hospitals. Between May and October 2000, 62 completed critical incident forms were collected. The nature of the incident and the monitoring used were recorded, the cause was classified as human, equipment or monitoring failure and the outcome for each patient reported. There was no formal system for reminding staff to fill in their critical incident forms. A total of 14,165 operations were performed over the reporting period: 62 critical incident forms were collected, reporting 130 incidents, giving a rate of 0.92% (130/14,165). Of these, 42 patients were emergencies and 20 elective. The incidents were hypotension, hypoxia, bradycardia, ECG changes, aspiration, laryngospasm, high spinal, and cardiac arrest. Monitoring present on patients who had critical incidents was: capnography 57%, oxymetry 90% and ECG 100%. Other monitors are not reported. Human error contributed in 32/62 of patients and equipment failure in 31/62 of patients. Patient outcome showed 15% died, 23% were unplanned admissions to HDU while 62% were discharged to the ward with little or no adverse outcome. Despite some under reporting, the critical incident rate was within the range reported in the literature. Supervision of juniors is not adequate, especially on call. The

  7. The Accuracy and Precision of Position and Orientation Tracking in the HTC Vive Virtual Reality System for Scientific Research

    Directory of Open Access Journals (Sweden)

    Diederick C. Niehorster

    2017-05-01

    Full Text Available The advent of inexpensive consumer virtual reality equipment enables many more researchers to study perception with naturally moving observers. One such system, the HTC Vive, offers a large field-of-view, high-resolution head mounted display together with a room-scale tracking system for less than a thousand U.S. dollars. If the position and orientation tracking of this system is of sufficient accuracy and precision, it could be suitable for much research that is currently done with far more expensive systems. Here we present a quantitative test of the HTC Vive’s position and orientation tracking as well as its end-to-end system latency. We report that while the precision of the Vive’s tracking measurements is high and its system latency (22 ms is low, its position and orientation measurements are provided in a coordinate system that is tilted with respect to the physical ground plane. Because large changes in offset were found whenever tracking was briefly lost, it cannot be corrected for with a one-time calibration procedure. We conclude that the varying offset between the virtual and the physical tracking space makes the HTC Vive at present unsuitable for scientific experiments that require accurate visual stimulation of self-motion through a virtual world. It may however be suited for other experiments that do not have this requirement.

  8. Progressive systemic scleroderma (A case report)

    International Nuclear Information System (INIS)

    Han, Jung Suh; Kwon, Chung Sik

    1974-01-01

    This is a report of a rare case of progressive systemic scleroderma involving the skin, lungs, bones, esophagus, duodenum, and colon in a 27 year old Korean female whose chief complaints were generalized edema, knee joint pain, hard and indurated skin lesions on the anterior chest, neck, both upper and lower extremities with loss of pain and touch sensation for one year. A review of literature is submitted

  9. Progressive systemic scleroderma (A case report)

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jung Suh; Kwon, Chung Sik [Chonnam University College of Medicine, Kwangju (Korea, Republic of)

    1974-10-15

    This is a report of a rare case of progressive systemic scleroderma involving the skin, lungs, bones, esophagus, duodenum, and colon in a 27 year old Korean female whose chief complaints were generalized edema, knee joint pain, hard and indurated skin lesions on the anterior chest, neck, both upper and lower extremities with loss of pain and touch sensation for one year. A review of literature is submitted.

  10. Using Surgeon-Specific Outcome Reports and Positive Deviance for Continuous Quality Improvement.

    Science.gov (United States)

    Ivanovic, Jelena; Anstee, Caitlin; Ramsay, Tim; Gilbert, Sebastien; Maziak, Donna E; Shamji, Farid M; Sundaresan, R Sudhir; Villeneuve, P James; Seely, Andrew J E

    2015-10-01

    Using the thoracic morbidity and mortality classification to document all postoperative adverse events between October 2012 and February 2014, we created surgeon-specific outcome reports (SSORs) to promote self-assessment and to implement a divisional continuous quality improvement (CQI) program, on the construct of positive deviance, to improve individual surgeon's clinical performance. Mixed-methods study within a division of six thoracic surgeons, involving (1) development of real-time, Web-based, risk-adjusted SSORs; (2) implementation of CQI seminars (n = 6; September 2013 to June 2014) for evaluation of results, collegial discussion on quality improvement based on identification of positive outliers, and selection of quality indicators for future discussion; and (3) in-person interviews to identify facilitators and barriers to using SSORs and CQI. Interview transcripts were analyzed using thematic analysis. Interviews revealed enthusiastic support for SSORs as a means to improve patient care through awareness of personal outcomes with blinded divisional comparison for similar operations and diseases, and apply the learning objectives to continuous professional development and maintenance of certification. Perceived limitations of SSORs included difficulty measuring surgeon expertise, limited understanding of risk adjustment, resistance to change, and belief that knowledge of sensitive data could lead to punitive actions. All surgeons believed CQI seminars led to collegial discussions, whereas perceived limitations included quorum participation and failing to circle back on actionable items. Real-time performance feedback using SSORs can motivate surgeons to improve their practice, and CQI seminars offer the opportunity to review and interpret results and address issues in a supportive environment. Whether SSORs and CQI can lead to improvements in rates of postoperative adverse events is a matter of ongoing research. Copyright © 2015 The Society of Thoracic

  11. Mobile Robot Positioning by using Low-Cost Visual Tracking System

    Directory of Open Access Journals (Sweden)

    Ruangpayoongsak Niramon

    2017-01-01

    Full Text Available This paper presents an application of visual tracking system on mobile robot positioning. The proposed method is verified on a constructed low-cost tracking system consisting of 2 DOF pan-tilt unit, web camera and distance sensor. The motion of pan-tilt joints is realized and controlled by using LQR controller running on microcontroller. Without needs of camera calibration, robot trajectory is tracked by Kalman filter integrating distance information and joint positions. The experimental results demonstrate validity of the proposed positioning technique and the obtained mobile robot trajectory is benchmarked against laser rangefinder positioning. The implemented system can successfully track a mobile robot driving at 14 cm/s.

  12. Infrared Sensor System for Mobile-Robot Positioning in Intelligent Spaces

    Directory of Open Access Journals (Sweden)

    Luis Pallarés Puerto

    2011-05-01

    Full Text Available The aim of this work was to position a Mobile Robot in an Intelligent Space, and this paper presents a sensorial system for measuring differential phase-shifts in a sinusoidally modulated infrared signal transmitted from the robot. Differential distances were obtained from these phase-shifts, and the position of the robot was estimated by hyperbolic trilateration. Due to the extremely severe trade-off between SNR, angle (coverage and real-time response, a very accurate design and device selection was required to achieve good precision with wide coverage and acceptable robot speed. An I/Q demodulator was used to measure phases with one-stage synchronous demodulation to DC. A complete set of results from real measurements, both for distance and position estimations, is provided to demonstrate the validity of the system proposed, comparing it with other similar indoor positioning systems.

  13. Design and measurement of signal processing system for cavity beam position monitor

    International Nuclear Information System (INIS)

    Wang Baopeng; Leng Yongbin; Yu Luyang; Zhou Weimin; Yuan Renxian; Chen Zhichu

    2013-01-01

    In this paper, in order to achieve the output signal processing of cavity beam position monitor (CBPM), we develop a digital intermediate frequency receiver architecture based signal processing system, which consists of radio frequency (RF) front end and high speed data acquisition board. The beam position resolution in the CBPM signal processing system is superior to 1 μm. Two signal processing algorithms, fast Fourier transform (FFT) and digital down converter (DDC), are evaluated offline using MATLAB platform, and both can be used to achieve, the CW input signal, position resolutions of 0.31 μm and 0.10 μm at -16 dBm. The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement, reaching the position resolution of 0.49 μm due to truncation error. The whole system works well and the performance meets design target. (authors)

  14. Positioning and tracking control system analysis for mobile free space optical network

    Science.gov (United States)

    Li, Yushan; Refai, Hazem; Sluss, , James J., Jr.; Verma, Pramode; LoPresti, Peter

    2005-08-01

    Free Space Optical (FSO) communication has evolved to be applied to the mobile network, because it can provide up to 2.5Gbps or higher data rate wireless communication. One of the key challenges with FSO systems is to maintain the Line of Sight (LOS) between transmitter and receiver. In this paper, the feasibility and performance of applying the FSO technology to the mobile network is explored, and the design plan of the attitude positioning and tracking control system of the FSO transceiver is investigated. First, the system architecture is introduced, the requirements for the control system are analyzed, the involved reference frames and frame transformation are presented. Second, the control system bandwidth is used to evaluate the system performance in controlling a positioning system consisting of a gimbal and a steering mirror, some definitions to describe the positioning accuracy and tracking capacity are given. The attitude control of a FSO transceiver is split into 2 similar channels: pitch and yaw. Using an equivalent linear control system model, the simulations are carried out, with and without the presence of uncertainties that includes GPS data errors and sensor measurement errors. Finally, based on the simulation results in the pitch channel, the quantitative evaluation on the performance of the control system is given, including positioning accuracy, tracking capability and uncertainty tolerance.

  15. Residual energy applications program systems analysis report

    Energy Technology Data Exchange (ETDEWEB)

    Yngve, P.W.

    1980-10-01

    Current DOE plans call for building an Energy Applied Systems Test (EAST) Facility at the Savannah River Plant in close proximity to the 140 to 150/sup 0/F waste heat from one of several operating nuclear reactors. The waste water flow from each reactor, approximately 165,000 gpm, provides a unique opportunity to test the performance and operating characteristics of large-scale waste heat power generation and heat pump system concepts. This report provides a preliminary description of the potential end-use market, parametric data on heat pump and the power generation system technology, a preliminary listing of EAST Facility requirements, and an example of an integrated industrial park utilizing the technology to maximize economic pay back. The parametric heat pump analysis concluded that dual-fluid Rankine cycle heat pumps with capacities as high as 400 x 10/sup 6/ Btu/h, can utilize large sources of low temperature residual heat to provide 300/sup 0/F saturatd steam for an industrial park. The before tax return on investment for this concept is 36.2%. The analysis also concluded that smaller modular heat pumps could fulfill the same objective while sacrificing only a moderate rate of return. The parametric power generation analysis concluded that multi-pressure Rankine cycle systems not only are superior to single pressure systems, but can also be developed for large systems (approx. = 17 MW/sub e/). This same technology is applicable to smaller systems at the sacrifice of higher investment per unit output.

  16. French power system reliability report 2008

    International Nuclear Information System (INIS)

    Tesseron, J.M.

    2009-06-01

    The reliability of the French power system was fully under control in 2008, despite the power outage in the eastern part of the Provence-Alpes-Cote d'Azur region on November 3, which had been dreaded for several years, since it had not been possible to set up a structurally adequate network. Pursuant to a consultation meeting, the reinforcement solution proposed by RTE was approved by the Minister of Energy, boding well for greater reliability in future. Based on the observations presented in this 2008 Report, RTE's Power System Reliability Audit Mission considers that no new recommendations are needed beyond those expressed in previous reliability reports and during reliability audits. The publication of this yearly report is in keeping with RTE's goal to promote the follow-up over time of the evolution of reliability in its various aspects. RTE thus aims to contribute to the development of reliability culture, by encouraging an improved assessment by the different players (both RTE and network users) of the role they play in building reliability, and by advocating the taking into account of reliability and benchmarking in the European organisations of Transmission System Operators. Contents: 1 - Brief overview of the evolution of the internal and external environment; 2 - Operating situations encountered: climatic conditions, supply / demand balance management, operation of interconnections, management of internal congestion, contingencies affecting the transmission facilities; 3 - Evolution of the reliability reference guide: external reference guide: directives, laws, decrees, etc, ETSO, UCTE, ENTSO-E, contracting contributing to reliability, RTE internal reference guide; 4 - Evolution of measures contributing to reliability in the equipment field: intrinsic performances of components (generating sets, protection systems, operation PLC's, instrumentation and control, automatic frequency and voltage controls, transmission facilities, control systems, load

  17. Sensory systems for a control rod position using reed switches for the integral reactor

    International Nuclear Information System (INIS)

    Yu, J. Y.; Choi, S.; Kim, J. H.; Lee, D. J.

    2007-01-01

    The system-integrated modular advanced reactor (SMART) currently under development at the Korea Atomic Energy Research Institute is being designed with a soluble boron free operation and the use of nuclear heating for the reactor start-up. These design features require a Control Element Drive Mechanism (CEDM) for the SMART to have a fine-step movement capability as well as a high reliability for a fine reactivity control. Also the reliability and accuracy of the information for the control rod position is very important to the reactor safety as well as the design of the core protection system. The position indicator is classified as a Class 1E component because the rod position signal of the position indicator is used in the safety related systems. Therefore it will be separated from the control systems to the extent that a failure of any single control system component of a channel and shall have sufficient independence, redundancy, and testability to perform its safety functions assuming a single failure. The position indicator is composed of a permanent magnet, reed switches and a voltage divider. Four independent position indicators around the upper pressure housing provide an indication of the position of a control rod comprising of a permanent magnet with a magnetic field concentrator which moves with the extension shaft connected to the control rod. The zigzag arranged reed switches are positioned along a line parallel to the path of the movement of the permanent magnet and it is activated selectively when the permanent magnet passes by. A voltage divider electrically connected to the reed switches provides a signal commensurate with the position of the control rod. The signal may then be transmitted to a position indicating device. In order to monitor the operating condition of the rotary step motor of CEDM, the angular position detector was installed at the top of the rotary step motor by means of connecting between the planetary gear and the rotating

  18. Preliminary Systems Design Study assessment report

    International Nuclear Information System (INIS)

    Mayberry, J.L.; Feizollahi, F.; Del Signore, J.C.

    1992-01-01

    The System Design Study (SDS), part of the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examined techniques available for the remediation of hazardous and transuranic waste stored at the Radioactive Waste Management Complex's Subsurface Disposal Area at the INEL. Using specific technologies, system concepts for treating the buried waste and the surrounding contaminated soil were evaluated. Evaluation included implementability, effectiveness, and cost. The SDS resulted in the development of technology requirements including demonstration, testing, and evaluation activities needed for implementing each concept. This volume of the Systems Design Study contain four Appendixes that were part of the study. Appendix A is an EG ampersand G Idaho, Inc., report that represents a review and compilation of previous reports describing the wastes and quantities disposed in the Subsurface Disposal Area of the Idaho National Engineering Laboratory. Appendix B contains the process flowsheets considered in this study, but not selected for detailed analysis. Appendix C is a historical tabulation of radioactive waste incinerators. Appendix D lists Department of Energy facilities where cementation stabilization systems have been used

  19. Final Report: Hydrogen Storage System Cost Analysis

    Energy Technology Data Exchange (ETDEWEB)

    James, Brian David [Strategic Analysis Inc., Arlington, VA (United States); Houchins, Cassidy [Strategic Analysis Inc., Arlington, VA (United States); Huya-Kouadio, Jennie Moton [Strategic Analysis Inc., Arlington, VA (United States); DeSantis, Daniel A. [Strategic Analysis Inc., Arlington, VA (United States)

    2016-09-30

    The Fuel Cell Technologies Office (FCTO) has identified hydrogen storage as a key enabling technology for advancing hydrogen and fuel cell power technologies in transportation, stationary, and portable applications. Consequently, FCTO has established targets to chart the progress of developing and demonstrating viable hydrogen storage technologies for transportation and stationary applications. This cost assessment project supports the overall FCTO goals by identifying the current technology system components, performance levels, and manufacturing/assembly techniques most likely to lead to the lowest system storage cost. Furthermore, the project forecasts the cost of these systems at a variety of annual manufacturing rates to allow comparison to the overall 2017 and “Ultimate” DOE cost targets. The cost breakdown of the system components and manufacturing steps can then be used to guide future research and development (R&D) decisions. The project was led by Strategic Analysis Inc. (SA) and aided by Rajesh Ahluwalia and Thanh Hua from Argonne National Laboratory (ANL) and Lin Simpson at the National Renewable Energy Laboratory (NREL). Since SA coordinated the project activities of all three organizations, this report includes a technical description of all project activity. This report represents a summary of contract activities and findings under SA’s five year contract to the US Department of Energy (Award No. DE-EE0005253) and constitutes the “Final Scientific Report” deliverable. Project publications and presentations are listed in the Appendix.

  20. Dynamic tracking performance of indoor global positioning system: An experimental and theoretical study

    Directory of Open Access Journals (Sweden)

    Gang Zhao

    2015-10-01

    Full Text Available The automation level has been improved rapidly with the introduction of large-scale measurement technologies, such as indoor global positioning system, into the production process among the fields of car, ship, and aerospace due to their excellent measurement characteristics. In fact, the objects are usually in motion during the real measurement process; however, the dynamic measurement characteristics of indoor global positioning system are much limited and still in exploration. In this research, we focused on the dynamic tracking performance of indoor global positioning system and then successfully built a mathematical model based on its measurement principles. We first built single and double station system models with the consideration of measurement objects’ movement. Using MATLAB simulation, we realized the dynamic measurement characteristics of indoor global positioning system. In the real measurement process, the experimental results also support the mathematical model that we built, which proves a great success in dynamic measurement characteristics. We envision that this dynamic tracking performance of indoor global positioning system would shed light on the dynamic measurement of a motion object and therefore make contribution to the automation production.