WorldWideScience

Sample records for position measurement mechanism

  1. Filtering for distributed mechanical systems using position measurements: perspectives in medical imaging

    International Nuclear Information System (INIS)

    Moireau, Philippe; Chapelle, Dominique; Tallec, Patrick Le

    2009-01-01

    We propose an effective filtering methodology designed to perform estimation in a distributed mechanical system using position measurements. As in a previously introduced method, the filter is inspired by robust control feedback, but here we take full advantage of the estimation specificity to choose a feedback law that can act on displacements instead of velocities and still retain the same kind of dissipativity property which guarantees robustness. This is very valuable in many applications for which positions are more readily available than velocities, as in medical imaging. We provide an in-depth analysis of the proposed procedure, as well as detailed numerical assessments using a test problem inspired by cardiac biomechanics, as medical diagnosis assistance is an important perspective for this approach. The method is formulated first for measurements based on Lagrangian displacements, but we then derive a nonlinear extension allowing us to instead consider segmented images, which of course is even more relevant in medical applications

  2. Angular Positioning Sensor for Space Mechanisms

    Science.gov (United States)

    Steiner, Nicolas; Chapuis, Dominique

    2013-09-01

    Angular position sensors are used on various rotating mechanisms such as solar array drive mechanisms, antenna pointing mechanisms, scientific instruments, motors or actuators.Now a days, potentiometers and encoders are mainly used for angular measurement purposes. Both of them have their own pros and cons.As alternative, Ruag Space Switzerland Nyon (RSSN) is developing and qualifying two innovative technologies of angular position sensors which offer easy implementation, medium to very high lifetime and high flexibility with regards to the output signal shape/type.The Brushed angular position sensor uses space qualified processes which are already flying on RSSN's sliprings for many years. A large variety of output signal shape can be implemented to fulfill customer requirements (digital, analog, customized, etc.).The contactless angular position sensor consists in a new radiation hard Application Specific Integrated Circuit (ASIC) based on the Hall effect and providing the angular position without complex processing algorithm.

  3. Sequential Modular Position and Momentum Measurements of a Trapped Ion Mechanical Oscillator

    Science.gov (United States)

    Flühmann, C.; Negnevitsky, V.; Marinelli, M.; Home, J. P.

    2018-04-01

    The noncommutativity of position and momentum observables is a hallmark feature of quantum physics. However, this incompatibility does not extend to observables that are periodic in these base variables. Such modular-variable observables have been suggested as tools for fault-tolerant quantum computing and enhanced quantum sensing. Here, we implement sequential measurements of modular variables in the oscillatory motion of a single trapped ion, using state-dependent displacements and a heralded nondestructive readout. We investigate the commutative nature of modular variable observables by demonstrating no-signaling in time between successive measurements, using a variety of input states. Employing a different periodicity, we observe signaling in time. This also requires wave-packet overlap, resulting in quantum interference that we enhance using squeezed input states. The sequential measurements allow us to extract two-time correlators for modular variables, which we use to violate a Leggett-Garg inequality. Signaling in time and Leggett-Garg inequalities serve as efficient quantum witnesses, which we probe here with a mechanical oscillator, a system that has a natural crossover from the quantum to the classical regime.

  4. Measurement of LHCD antenna position in Aditya tokamak

    International Nuclear Information System (INIS)

    Ambulkar, K K; Sharma, P K; Virani, C G; Parmar, P R; Thakur, A L; Kulkarni, S V

    2010-01-01

    To drive plasma current non-inductively in ADITYA tokamak, 120 kW pulsed Lower Hybrid Current Drive (LHCD) system at 3.7 GHz has been designed, fabricated and installed on ADITYA tokamak. In this system, the antenna consists of a grill structure, having two rows, each row comprising of four sub-waveguides. The coupling of LHCD power to the plasma strongly depends on the plasma density near the mouth of grill antenna. Thus the grill antenna has to be precisely positioned for efficient coupling. The movement of mechanical bellow, which contracts or expands up to 50mm, governs the movement of antenna. In order to monitor the position of the antenna precisely, the reference position of the antenna with respect to the machine/plasma position has to be accurately determined. Further a mechanical system or an electronic system to measure the relative movement of the antenna with respect to the reference position is also desired. Also due to poor accessibility inside the ADITYA machine, it is impossible to measure physically the reference position of the grill antenna with respect to machine wall, taken as reference position and hence an alternative method has to be adopted to establish these measurements reliably. In this paper we report the design and development of a mechanism, using which the antenna position measurements are made. It also describes a unique method employing which the measurements of the reference position of the antenna with respect to the inner edge of the tokamak wall is carried out, which otherwise was impossible due to poor accessibility and physical constraints. The position of the antenna is monitored using an electronic scale, which is developed and installed on the bellow. Once the reference position is derived, the linear potentiometer, attached to the bellow, measures the linear distance using position transmitter. The accuracy of measurement obtained in our setup is within +/- 0.5 % and the linearity, along with repeatability is excellent.

  5. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  6. Quantum Backaction Evading Measurement of Collective Mechanical Modes.

    Science.gov (United States)

    Ockeloen-Korppi, C F; Damskägg, E; Pirkkalainen, J-M; Clerk, A A; Woolley, M J; Sillanpää, M A

    2016-09-30

    The standard quantum limit constrains the precision of an oscillator position measurement. It arises from a balance between the imprecision and the quantum backaction of the measurement. However, a measurement of only a single quadrature of the oscillator can evade the backaction and be made with arbitrary precision. Here we demonstrate quantum backaction evading measurements of a collective quadrature of two mechanical oscillators, both coupled to a common microwave cavity. The work allows for quantum state tomography of two mechanical oscillators, and provides a foundation for macroscopic mechanical entanglement and force sensing beyond conventional quantum limits.

  7. The 1 Repetition Maximum Mechanics of a High-Handle Hexagonal Bar Deadlift Compared With a Conventional Deadlift as Measured by a Linear Position Transducer.

    Science.gov (United States)

    Lockie, Robert G; Moreno, Matthew R; Lazar, Adrina; Risso, Fabrice G; Liu, Tricia M; Stage, Alyssa A; Birmingham-Babauta, Samantha A; Torne, Ibett A; Stokes, John J; Giuliano, Dominic V; Davis, DeShaun L; Orjalo, Ashley J; Callaghan, Samuel J

    2018-01-01

    Lockie, RG, Moreno, MR, Lazar, A, Risso, FG, Liu, TM, Stage, AA, Birmingham-Babauta, SA, Torne, IA, Stokes, JJ, Giuliano, DV, Davis, DL, Orjalo, AJ, and Callaghan, SJ. The 1 repetition maximum mechanics of a high-handle hexagonal bar deadlift compared with a conventional deadlift as measured by a linear position transducer. J Strength Cond Res 32(1): 150-161, 2018-The high-handle hexagonal bar deadlift (HHBD), a variation of the conventional deadlift (CD), is said to reduce the lift range of motion, which may change the mechanics of the lift. However, no research has investigated this. This study compared the mechanics between a 1 repetition maximum (1RM) CD and HHBD. Thirty-one strength-trained subjects (21 men, 10 women) completed a 1RM CD and HHBD. A linear position transducer measured lift distance, duration, and work; and peak and mean power, velocity, and force. The presence of a sticking region (SR) was determined for each lift. A repeated-measures analysis of variance (ANOVA) calculated differences between 1RM CD and HHBD mechanics. A one-way ANOVA compared the mechanics of each lift between subjects who exhibited an SR or not, and the SR between the CD and HHBD. Significance was set at p mechanics between subjects with or without an SR, and no differences in SR region distance or duration between the CD and HHBD. Greater force can be generated in the HHBD, which could have implications for strength-training adaptations over time.

  8. Robust Position Control of Electro-mechanical Systems

    OpenAIRE

    Rong Mei; Mou Chen

    2013-01-01

    In this work, the robust position control scheme is proposed for the electro-mechanical system using the disturbance observer and backstepping control method. To the external unknown load of the electro-mechanical system, the nonlinear disturbance observer is given to estimate the external unknown load. Combining the output of the developed nonlinear disturbance observer with backstepping technology, the robust position control scheme is proposed for the electro-mechanical system. The stabili...

  9. Mechanical measurements in RFX-mod experiment

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, M., E-mail: mauro.dallapalma@igi.cnr.it [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, 35127 Padova (Italy); Ravarotto, D.; Dal Bello, S.; Fincato, M.; Ghiraldelli, R.; Marchiori, G.; Taliercio, C.; Zaccaria, P. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, 35127 Padova (Italy)

    2010-12-15

    The ongoing experimental campaigns of RFX-mod are performed setting operational parameters at the nominal or exceeding design values of the experiment. Compressive forces up to 11 MN are produced by high magnetizing currents that reach values up to 50 kA. These forces heavily load the mechanical structure of RFX-mod and their effects are measured and monitored in order to assess the expected structural response and machine reliability during operation. Mechanical strains and relative displacements are real time measured during each experimental pulse by 48 strain gauges located on 12 mechanical struts and 16 potentiometers positioned between the toroidal assembly and the support mechanical structure. The strains in the most stressed components are measured by means of 24 half bridge gauges preliminarily calibrated. Particular care has been given to sensor choices and installation in order to minimize signal noises induced by the electrical and magnetic fields. The residual noises have been further reduced by proper sampling frequency and averaging techniques. The strains measured on the struts are then post-processed to calculate the resultant forces and bending moments, while the displacement measurements give an estimate of the overall stiffness of the mechanical structure. The measured forces and displacements are shown per toroidal locations and as a function of the current intensity, so verifying the uniform sharing of forces among the different struts and the proper square law correlation with the magnetizing current intensity.

  10. Measurement of Gamma Radiation in an Automobile Mechanic ...

    African Journals Online (AJOL)

    Environmental radiation measurement was carried out in an automobile mechanic village, Apo, Abuja, Nigeria. An in-situ measurement approach was adopted using RDS-200 Universal Survey Meter and a handheld Global Positioning System (Garmin GPS 76S) equipment. It was observed that the dose equivalent varied ...

  11. Analysis of Links Positions in Landing Gear Mechanism

    Science.gov (United States)

    Brewczyński, D.; Tora, G.

    2014-08-01

    This article contains a kinematic analysis of an aircraft chassis mechanism in a range of positions. The mechanism of the chassis is made up of several smaller subsystems with different functions. The first mechanism is used to eject the chassis before landing (touchdown) and fold it to hatchway after the lift off. The second mechanism is designed to perform rotation of the crossover with the wheel, in order to adjust the position of the wheel to fit it in the limited space in the hold. The third mechanism allows movement of the chassis resulting from the change in length of the damper. To determine the position of the following links of the mechanism calculus of vectors was applied in which unit vectors were used to represent the angular position of the links. The aim of the analysis is to determine the angle of convergence and the angle of heel wheels as a function of the variable length of hydraulic cylinder, length of the shock absorber, length of the regulations rods

  12. Position sensor without any mechanical contact

    International Nuclear Information System (INIS)

    Ambier, Jean.

    1976-01-01

    The invention concerns a system for detecting, without any mechanical contact, the position of a mobile element according to a pre-determined path. The sensor includes a primary winding fed by an AC source and a secondary winding inductively coupled with the primary winding and subdivided into elementary coils, spaced out along this path and electrically inter-connected in couples. The mobile element has a magnetic part capable of modifying the inductive coupling between the windings, a secondary coil couple delivering a differential signal of zero values for all positions of the mobile element generating the same inductive coupling of each coil of the couple to the said primary winding. The main patent describes a system making it possible to detect the position of the rods in a nuclear reactor. The need was felt to improved the measuring accuracy of the sensor and to have a rigid front signal for easy electronic processing. The purpose of this invention is to improve the standard sensor to this end and it is characterised by the fact that the primary winding is subdivided into the same number of elementary coils as the secondary winding and that a primary coil is associated to each secondary coil, the two associated coils being coiled one on the other. The saving in space enables the coils to be brought closer together and affords an increase in measurement accuracy. A magnetic screen isolates each pair of coils and channels the leakage flux, the screen sharing in the localisation of the magnetic field under each pair of coils to achieve a sudden variation and a rigid front of the signal during the displacement of the mobile element [fr

  13. Enhancement of control rod drive mechanism seating position detector for JRR-3

    International Nuclear Information System (INIS)

    Ohuchi, Satoshi; Kurumada, Osamu; Kamiishi, Eigo; Sato, Masayuki; Ikekame, Yoshinori; Wada, Shigeru

    2016-06-01

    The purpose of the control rod drive mechanism seating position detector for JRR-3 is one of methods for confirming the shutdown condition of the reactor and sending out the seat position signal to other systems. The detector has been utilizing more than 25 years with maintenance regularly. However, some troubles occurred recently. Moreover, the detector has already been discontinued, and it is confirmed that the successor detector is unsuitable for the control rod drive mechanism of JRR-3. Therefore, it was necessary to select the adequate detector to the control rod drive mechanism of JRR-3. Accordingly, we built a test device with the aim of verifying several detectors for integrity and function. At the time of the test for performance confirmation, it was occurred unexpected problems. Nevertheless, we devise improvement of the problems and took measures. Thus we were able to make adequate detector for JRR-3 and replace to enhanced detector. This paper reports the Enhanced of Control rod drive mechanism seating position detector. (author)

  14. Quantum measurement with a positive operator-valued measure

    International Nuclear Information System (INIS)

    Brandt, Howard E

    2003-01-01

    In the quantum theory of measurement, the positive operator-valued measure (POVM) is an important concept, and its implementation can be useful. A POVM consists of a set of non-negative quantum-mechanical Hermitian operators that add up to the identity. The probability that a quantum system is in a particular state is given by the expectation value of the POVM operator corresponding to that state. Following a brief review of the mathematics and mention of the history of POVMs in quantum theory, a particular implementation of a POVM for use in the measurement of nonorthogonal photon polarization states is reviewed. The implementation consists simply of a Wollaston prism, a mirror, two beam splitters, a polarization rotator and three phototubes arranged in an interferometric configuration, and it is shown analytically that the device faithfully represents the POVM. Based on Neumark's extension theorem, the two-dimensional Hilbert space of the POVM implementation can be embedded in the three-dimensional Hilbert space of an ordinary projective-valued measure. Also, analytical expressions are given for the maximum Renyi information loss from the device to a disturbing probe, and for the error and inconclusive rates induced by the probe. Various aspects of the problem of probe optimization are elaborated

  15. Position measurement of the direct drive motor of Large Aperture Telescope

    Science.gov (United States)

    Li, Ying; Wang, Daxing

    2010-07-01

    Along with the development of space and astronomy science, production of large aperture telescope and super large aperture telescope will definitely become the trend. It's one of methods to solve precise drive of large aperture telescope using direct drive technology unified designed of electricity and magnetism structure. A direct drive precise rotary table with diameter of 2.5 meters researched and produced by us is a typical mechanical & electrical integration design. This paper mainly introduces position measurement control system of direct drive motor. In design of this motor, position measurement control system requires having high resolution, and precisely aligning the position of rotor shaft and making measurement, meanwhile transferring position information to position reversing information corresponding to needed motor pole number. This system has chosen high precision metal band coder and absolute type coder, processing information of coders, and has sent 32-bit RISC CPU making software processing, and gained high resolution composite coder. The paper gives relevant laboratory test results at the end, indicating the position measurement can apply to large aperture telescope control system. This project is subsidized by Chinese National Natural Science Funds (10833004).

  16. Physical Limits on the Precision of Mitotic Spindle Positioning by Microtubule Pushing forces: Mechanics of mitotic spindle positioning.

    Science.gov (United States)

    Howard, Jonathon; Garzon-Coral, Carlos

    2017-11-01

    Tissues are shaped and patterned by mechanical and chemical processes. A key mechanical process is the positioning of the mitotic spindle, which determines the size and location of the daughter cells within the tissue. Recent force and position-fluctuation measurements indicate that pushing forces, mediated by the polymerization of astral microtubules against- the cell cortex, maintain the mitotic spindle at the cell center in Caenorhabditis elegans embryos. The magnitude of the centering forces suggests that the physical limit on the accuracy and precision of this centering mechanism is determined by the number of pushing microtubules rather than by thermally driven fluctuations. In cells that divide asymmetrically, anti-centering, pulling forces generated by cortically located dyneins, in conjunction with microtubule depolymerization, oppose the pushing forces to drive spindle displacements away from the center. Thus, a balance of centering pushing forces and anti-centering pulling forces localize the mitotic spindles within dividing C. elegans cells. © 2017 The Authors. BioEssays published by Wiley Periodicals, Inc.

  17. Interconnection and Damping Assignment Passivity-Based Control for Port-Hamiltonian mechanical systems with only position measurements

    NARCIS (Netherlands)

    Dirksz, D. A.; Scherpen, J. M. A.; Ortega, R.

    2008-01-01

    A dynamic extension for position feedback of port-Hamiltonian mechanical systems is studied. First we look at the consequences for the matching equations when applying Interconnection and Damping Assignment Passivity-Based Control (IDA-PBC). Then we look at the possibilities of asymptotically

  18. Support force measures of midsized men in seated positions.

    Science.gov (United States)

    Bush, Tamara Reid; Hubbard, Robert P

    2007-02-01

    Two areas not well researched in the field of seating mechanics are the distribution of normal and shear forces, and how those forces change with seat position. The availability of these data would be beneficial for the design and development of office, automotive and medical seats. To increase our knowledge in the area of seating mechanics, this study sought to measure the normal and shear loads applied to segmental supports in 12 seated positions, utilizing three inclination angles and four levels of seat back articulation that were associated with automotive driving positions. Force data from six regions, including the thorax, sacral region, buttocks, thighs, feet, and hand support were gathered using multi-axis load cells. The sample contained 23 midsized subjects with an average weight of 76.7 kg and a standard deviation of 4.2 kg, and an average height of 1745 mm with a standard deviation of 19 mm. Results were examined in terms of seat back inclination and in terms of torso articulation for relationships between seat positions and support forces. Using a repeated measures analysis, significant differences (p<0.05) were identified for normal forces relative to all inclination angles except for forces occurring at the hand support. Other significant differences were observed between normal forces behind the buttocks, pelvis, and feet for torso articulations. Significant differences in the shear forces occurred under the buttocks and posterior pelvis during changes in seat back inclination. Significant differences in shear forces were also identified for torso articulations. These data suggest that as seat back inclination or torso articulation change, significant shifts in force distribution occur.

  19. Improvement of the thermo-mechanical position stability of the beam position monitor in the PLS-II

    Science.gov (United States)

    Ha, Taekyun; Hong, Mansu; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-09-01

    In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.

  20. Positive-Operator Valued Measure (POVM Quantization

    Directory of Open Access Journals (Sweden)

    Jean Pierre Gazeau

    2014-12-01

    Full Text Available We present a general formalism for giving a measure space paired with a separable Hilbert space a quantum version based on a normalized positive operator-valued measure. The latter are built from families of density operators labeled by points of the measure space. We especially focus on various probabilistic aspects of these constructions. Simple ormore elaborate examples illustrate the procedure: circle, two-sphere, plane and half-plane. Links with Positive-Operator Valued Measure (POVM quantum measurement and quantum statistical inference are sketched.

  1. Detuned mechanical parametric amplification as a quantum non-demolition measurement

    International Nuclear Information System (INIS)

    Szorkovszky, A; Bowen, W P; Clerk, A A; Doherty, A C

    2014-01-01

    Recently it has been demonstrated that the combination of continuous position detection with detuned parametric driving can lead to significant steady-state mechanical squeezing, far beyond the 3 dB limit normally associated with parametric driving. In this work, we show the close connection between this detuned scheme and quantum non-demolition (QND) measurement of a single mechanical quadrature. In particular, we show that applying an experimentally realistic detuned parametric drive to a cavity optomechanical system allows one to effectively realize a QND measurement despite being in the bad-cavity limit. In the limit of strong squeezing, we show that this scheme offers significant advantages over standard backaction evasion, not only by allowing operation in the weak measurement and low efficiency regimes, but also in terms of the purity of the mechanical state

  2. Incentive-Rewarding Mechanism for User-position Control in Mobile Services

    Science.gov (United States)

    Yoshino, Makoto; Sato, Kenichiro; Shinkuma, Ryoichi; Takahashi, Tatsuro

    When the number of users in a service area increases in mobile multimedia services, no individual user can obtain satisfactory radio resources such as bandwidth and signal power because the resources are limited and shared. A solution for such a problem is user-position control. In the user-position control, the operator informs users of better communication areas (or spots) and navigates them to these positions. However, because of subjective costs caused by subjects moving from their original to a new position, they do not always attempt to move. To motivate users to contribute their resources in network services that require resource contributions for users, incentive-rewarding mechanisms have been proposed. However, there are no mechanisms that distribute rewards appropriately according to various subjective factors involving users. Furthermore, since the conventional mechanisms limit how rewards are paid, they are applicable only for the network service they targeted. In this paper, we propose a novel incentive-rewarding mechanism to solve these problems, using an external evaluator and interactive learning agents. We also investigated ways of appropriately controlling rewards based on user contributions and system service quality. We applied the proposed mechanism and reward control to the user-position control, and demonstrated its validity.

  3. Six movements measurement system employed for GAIA secondary mirror positioning system vacuum tests at cryogenic temperatures

    Science.gov (United States)

    Ramos Zapata, Gonzalo; Sánchez Rodríguez, Antonio; Garranzo García-Ibarrola, Daniel; Belenguer Dávila, Tomás

    2008-07-01

    In this work, the optical measurement system employed to evaluate the performance of a 6 degrees of freedom (dof) positioning mechanism under cryogenic conditions is explored. The mechanism, the flight model of three translations and three rotations positioning mechanism, was developed by the Spanish company SENER (for ASTRIUM) to fulfil the high performance requirements from ESA technology preparatory program for the positioning of a secondary mirror within the GAIA Astrometric Mission. Its performance has been evaluated under vacuum and temperature controlled conditions (up to a 10-6mbar and 100K) at the facilities of the Space Instrumentation Laboratory (LINES) of the Aerospace Technical Nacional Institute of Spain (INTA). After the description of the 'alignment tool' developed to compare a fixed reference with the optical signal corresponding to the movement under evaluation, the optical system that allows measuring the displacements and the rotations in the three space directions is reported on. Two similar bread-boards were defined and mounted for the measurements purpose, one containing two distancemeters, in order to measure the displacements through the corresponding axis, and an autocollimator in order to obtain the rotations on the plane whose normal vector is the axis mentioned before, and other one containing one distancemeter and one autocollimator. Both distancemeter and autocollimator measurements have been combined in order to extract the information about the accuracy of the mechanism movements as well as their repeatability under adverse environmental conditions.

  4. Research on position and orientation measurement method for roadheader based on vision/INS

    Science.gov (United States)

    Yang, Jinyong; Zhang, Guanqin; Huang, Zhe; Ye, Yaozhong; Ma, Bowen; Wang, Yizhong

    2018-01-01

    Roadheader which is a kind of special equipment for large tunnel excavation has been widely used in Coal Mine. It is one of the main mechanical-electrical equipment for mine production and also has been regarded as the core equipment for underground tunnel driving construction. With the deep application of the rapid driving system, underground tunnel driving methods with higher automation level are required. In this respect, the real-time position and orientation measurement technique for roadheader is one of the most important research contents. For solving the problem of position and orientation measurement automatically in real time for roadheaders, this paper analyses and compares the features of several existing measuring methods. Then a new method based on the combination of monocular vision and strap down inertial navigation system (SINS) would be proposed. By realizing five degree-of-freedom (DOF) measurement of real-time position and orientation of roadheader, this method has been verified by the rapid excavation equipment in Daliuta coal mine. Experiment results show that the accuracy of orientation measurement is better than 0.1°, the standard deviation of static drift is better than 0.25° and the accuracy of position measurement is better than 1cm. It is proved that this method can be used in real-time position and orientation measurement application for roadheader which has a broad prospect in coal mine engineering.

  5. A Connection Model between the Positioning Mechanism and Ultrasonic Measurement System via a Web Browser to Assess Acoustic Target Strength

    Science.gov (United States)

    Ishii, Ken; Imaizumi, Tomohito; Abe, Koki; Takao, Yoshimi; Tamura, Shuko

    This paper details a network-controlled measurement system for use in fisheries engineering. The target strength (TS) of fish is important in order to convert acoustic integration values obtained during acoustic surveys into estimates of fish abundance. The target strength pattern is measured with the combination of the rotation system for the aspect of the sample and the echo data acquisition system using the underwater supersonic wave. The user interface of the network architecture is designed for collaborative use with researchers in other organizations. The flexible network architecture is based on the web direct-access model for the rotation mechanism. The user interface is available for monitoring and controlling via a web browser that is installed in any terminal PC (personal computer). Previously the combination of two applications was performed not by a web browser but by the exclusive interface program. So a connection model is proposed between two applications by indirect communication via the DCOM (Distributed Component Object Model) server and added in the web direct-access model. A prompt report system in the TS measurement system and a positioning and measurement system using an electric flatcar via a web browser are developed. By a secure network architecture, DCOM communications via both Intranet and LAN are successfully certificated.

  6. Precision Measurement of the Position-Space Wave Functions of Gravitationally Bound Ultracold Neutrons

    Directory of Open Access Journals (Sweden)

    Y. Kamiya

    2014-01-01

    Full Text Available Gravity is the most familiar force at our natural length scale. However, it is still exotic from the view point of particle physics. The first experimental study of quantum effects under gravity was performed using a cold neutron beam in 1975. Following this, an investigation of gravitationally bound quantum states using ultracold neutrons was started in 2002. This quantum bound system is now well understood, and one can use it as a tunable tool to probe gravity. In this paper, we review a recent measurement of position-space wave functions of such gravitationally bound states and discuss issues related to this analysis, such as neutron loss models in a thin neutron guide, the formulation of phase space quantum mechanics, and UCN position sensitive detectors. The quantum modulation of neutron bound states measured in this experiment shows good agreement with the prediction from quantum mechanics.

  7. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  8. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  9. Tracking control mechanisms for positioning automatic CRD exchanger

    International Nuclear Information System (INIS)

    Koizumi, Akira; Takada, Satoshi.

    1984-01-01

    Purpose: To enable completely automatic positioning for the automatic CRD (control rod drives) exchanger, as well as shorten the time for the exchanging operation and save the operator's labour. Constitution: Images of a target attached to the lower flange face of CRD are picked up by a fiber scope mounted to a mounting head. The images are converted through I.T.V. into electrical signals, passed through a cable and then sent to a pattern recognition mechanism. The position for the images of the target is calculated and the calculated position is sent to a drive control section, where the position for the images of the target is compared with a reference position for the images (exactly aligned position) and the moving amount of the mounting head is calculated to move the driving section and thereby complete the positioning. (Kawakami, Y.)

  10. Development of Precise Point Positioning Method Using Global Positioning System Measurements

    Directory of Open Access Journals (Sweden)

    Byung-Kyu Choi

    2011-09-01

    Full Text Available Precise point positioning (PPP is increasingly used in several parts such as monitoring of crustal movement and maintaining an international terrestrial reference frame using global positioning system (GPS measurements. An accuracy of PPP data processing has been increased due to the use of the more precise satellite orbit/clock products. In this study we developed PPP algorithm that utilizes data collected by a GPS receiver. The measurement error modelling including the tropospheric error and the tidal model in data processing was considered to improve the positioning accuracy. The extended Kalman filter has been also employed to estimate the state parameters such as positioning information and float ambiguities. For the verification, we compared our results to other of International GNSS Service analysis center. As a result, the mean errors of the estimated position on the East-West, North-South and Up-Down direction for the five days were 0.9 cm, 0.32 cm, and 1.14 cm in 95% confidence level.

  11. Multiple Iterations of Bundle Adjustment for the Position Measurement of Fiber Tips on LAMOST

    Directory of Open Access Journals (Sweden)

    Feng Mingchi

    2014-08-01

    Full Text Available In the astronomical observation process of multi-object fiber spectroscopic telescope, the position measurement of fiber tips on the focal plane is difficult and critical, and is directly related to subsequent observation and ultimate data quality. The fibers should precisely align with the celestial target. Hence, the precise coordinates of the fiber tips are obligatory for tracking the celestial target. The accurate movement trajectories of the fiber tips on the focal surface of the telescope are the critical problem for the control of the fiber positioning mechanism. According to the special structure of the LAMOST telescope and the composition of the initial position error, this paper aims at developing a high precision and robust measurement method based on multiple iterations of bundle adjustment with a few control points. The measurement theory of the proposed methodology has been analyzed, and the measurement accuracy has been evaluated. The experimental results indicate that the new method is more accurate and more reliable than the polynomial fitting method. The maximum position error of the novel measurement algorithm of fiber tips with simulated and real data is 65.3 μm, and most of the position errors conform to the accuracy requirement (40 μm.

  12. The effect of mechanical stress on lateral-effect position-sensitive detector characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, H.A. [Department of Information Technology and Media, Mid-Sweden University, SE-85170 Sundsvall (Sweden)]. E-mail: Henrik.Andersson@miun.se; Mattsson, C.G. [Department of Information Technology and Media, Mid-Sweden University, SE-85170 Sundsvall (Sweden); Thungstroem, G. [Department of Information Technology and Media, Mid-Sweden University, SE-85170 Sundsvall (Sweden); Lundgren, A. [SiTek Electro Optics, Ogaerdesvaegen 13A 433 30 Partille (Sweden); Nilsson, H.-E. [Department of Information Technology and Media, Mid-Sweden University, SE-85170 Sundsvall (Sweden)

    2006-07-01

    Position-sensitive detectors (PSDs) are widely used in noncontact measurement systems. In order to minimize the size of such systems, interest has increased in mounting the PSD chip directly onto printed circuit boards (PCBs). Stress may be induced in the PSD because of the large differences in thermal expansion coefficients, as well as the long-term geometrical stability of the chip packaging. Mechanical stress has previously been shown to have an effect on the performance of semiconductors. The accuracy, or linearity, of a lateral effect PSD is largely dependent on the homogeneity of the resistive layer. Variations of the resistivity over the active area of the PSD will result in an uneven distribution of photo-generated current, and hence an error in the readout position. In this work experiments were performed to investigate the influence of anisotropic mechanical stress in terms of nonlinearity. PSD chips of 60x3 mm active area were subjected, respectively, to different amounts of compressive and tensile stress to determine the influence on the linearity.

  13. Prolonged lateral steep position impairs respiratory mechanics during continuous lateral rotation therapy in respiratory failure.

    Science.gov (United States)

    Schellongowski, Peter; Losert, Heidrun; Locker, Gottfried J; Laczika, Klaus; Frass, Michael; Holzinger, Ulrike; Bojic, Andja; Staudinger, Thomas

    2007-04-01

    To establish whether prolonged lateral steep position during continuous rotation therapy leads to improvement on pulmonary gas exchange, respiratory mechanics and hemodynamics. Prospective observational study. Intensive care unit of a university hospital. Twelve consecutive patients suffering from acute lung injury or adult respiratory distress syndrome undergoing continuous rotation therapy. Blood gas analysis, static lung compliance, blood pressure, cardiac index and pulmonary shunt fraction were measured in supine as well as in left and right lateral steep position at 62 degrees during continuous rotation therapy (phase I). Rotation was then stopped for 30 min with the patients in supine position, left and right lateral steep position, and the same measurements were performed every 10 min (phase II). Phase I and II revealed no significant changes in PaO(2)/FiO(2) ratio, mean arterial blood pressure, pulmonary shunt fraction, or cardiac index. Significantly lower static compliance was observed in lateral steep position than in supine position (pposition than in left and right lateral steep position (ppositioning impairs the compliance of the respiratory system. Prolonged lateral steep position does not lead to benefits with respect to oxygenation or hemodynamics. Individual response to the different positions is unpredictable. The pauses in "extreme" positions should be as short as possible.

  14. Mechanical Measurements Laboratory

    CERN Multimedia

    Maximilien Brice

    2007-01-01

    The CERN mechanical measurements team check the sensors on one of the ATLAS inner detector end-caps using high precision measurement equipment. Remote checks like this must be made on these sensitive detector components before they can be transported to make sure that all systems are working correctly.

  15. Simulation and measurement of short infrared pulses on silicon position sensitive device

    International Nuclear Information System (INIS)

    Krapohl, D; Esebamen, O X; Nilsson, H E; Thungstroem, G

    2011-01-01

    Lateral position sensitive devices (PSD) are important for triangulation, alignment and surface measurements as well as for angle measurements. Large PSDs show a delay on rising and falling edges when irradiated with near infra-red light. This delay is also dependent on the spot position relative to the electrodes. It is however desirable in most applications to have a fast response. We investigated the responsiveness of a Sitek PSD in a mixed mode simulation of a two dimensional full sized detector. For simulation and measurement purposes focused light pulses with a wavelength of 850 nm, duration of 1μs and spot size of 280μm were used. The cause for the slopes of rise and fall time is due to time constants of the device capacitance as well as the photo-generation mechanism itself. To support the simulated results, we conducted measurements of rise and fall times on a physical device. Additionally, we quantified the homogeneity of the device by repositioning a spot of light from a pulsed ir-laser diode on the surface area.

  16. Short-term effects of positive expiratory airway pressure in patients being weaned from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Marcelo de Mello Rieder

    2009-05-01

    Full Text Available OBJECTIVE: To investigate the feasibility and the cardiorespiratory effects of using positive expiratory airway pressure, a physiotherapeutic tool, in comparison with a T-tube, to wean patients from mechanical ventilation. METHODS/DESIGN: A prospective, randomized, cross-over study. SETTING: Two intensive care units. PATIENTS AND INTERVENTIONS: We evaluated forty patients who met weaning criteria and had been mechanically-ventilated for more than 48 hours, mean age 59 years, including 23 males. All patients were submitted to the T-tube and Expiratory Positive Airway Pressure devices, at 7 cm H2O, during a 30-minute period. Cardiorespiratory variables including work of breathing, respiratory rate (rr, peripheral oxygen saturation (SpO2, heart rate (hr, systolic, diastolic and mean arterial pressures (SAP, DAP, MAP were measured in the first and thirtieth minutes. The condition was analyzed as an entire sample set (n=40 and was also divided into subconditions: chronic obstructive pulmonary disease (n=14 and non-chronic obstructive pulmonary disease (non- chronic obstructive pulmonary disease (n=26 categories. Comparisons were made using a t-test and Analysis of Variance. The level of significance was p < 0.05. RESULTS: Our data showed an increase in work of breathing in the first and thirtieth minutes in the EPAP condition (0.86+ 0.43 and 1.02+1.3 as compared with the T-tube condition (0.25+0.26 and 0.26+0.35 (p<0.05, verified by the flow-sensor monitor (values in J/L. No statistical differences were observed when comparing the Expiratory Positive Airway Pressure and T-tube conditions with regard to cardiorespiratory measurements. The same result was observed for both chronic obstructive pulmonary disease and non- chronic obstructive pulmonary disease subconditions. CONCLUSIONS: Our study demonstrated that, in weaning patients from mechanical ventilation, the use of a fixed level of Expiratory Positive Airway Pressure caused an increase in work of

  17. Influence of standing position on mechanical and energy costs in uphill cycling.

    Science.gov (United States)

    Bouillod, Anthony; Pinot, Julien; Valade, Aurélien; Cassirame, Johan; Soto-Romero, Georges; Grappe, Frédéric

    2018-04-27

    This study was designed to examine the influence of standing position (vs. seated) during uphill cycling on both mechanical cost (MC) and energy cost (EC) in elite cyclists. For the study, thirteen elite cyclists (VO 2max : 71.4 ± 8.0 ml·min -1 ·kg -1 ) performed, in a randomised order, three sets of exercises. Each set comprised 2 min of exercise, alternating every 30 s between seated and standing postures, using different slopes and intensity levels on a motorised treadmill. MC was calculated from the measurement of power output and speed, whereas EC was calculated from the measurement of oxygen consumption and speed. MC was significantly higher (+4.3%, p tire manufacturers to reduce the increase in rolling resistance between the two positions. Considering the relationship observed between the MC and bicycle sways, cyclists would be well advised to decrease the bicycle sways in order to reduce the MC of locomotion. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Mechanical effects of strong measurement: back-action noise and cooling

    Science.gov (United States)

    Schwab, Keith

    2007-03-01

    Our recent experiments show that it is now possible to prepare and measure mechanical systems with thermal occupation factors of N˜25 and perform continuous position measurements close to the limits required by the Heisenberg Uncertainty Principle (1). I will discuss our back-action measurements with nanomechanical structures strongly coupled to single electron transistors. We have been able to observe the stochastic back-action forces exerted by the SET as well as a cooling effect which has analogies to cooling in optical cavities. Furthermore, I will discuss progress using optical fields coupled to mechanical modes which show substantial cooling using the pondermotive effects of the photons impacting a flexible dielectric mirror (2). Both of these techniques pave the way to demonstrating the true quantum properties of a mechanical device: squeezed states, superposition states, and entangled states. (1) ``Quantum Measurement Backaction and Cooling Observed with a Nanomechanical Resonator,'' A. Naik, O. Buu, M.D. LaHaye, M.P. Blencowe, A.D. Armour, A.A. Clerk, K.C. Schwab, Nature 443, 193 (2006). (2) ``Self-cooling of a micro-mirror by radiation pressure,'' S. Gigan, H.R. Boehm, M. Patemostro, F. Blaser, G. Langer, J. Hertzberg, K. Schwab, D. Baeuerle, M. Aspelmeyer, A. Zeilinger, Nature 444, 67 (2006).

  19. Electro-mechanical probe positioning system for large volume plasma device

    Science.gov (United States)

    Sanyasi, A. K.; Sugandhi, R.; Srivastava, P. K.; Srivastav, Prabhakar; Awasthi, L. M.

    2018-05-01

    An automated electro-mechanical system for the positioning of plasma diagnostics has been designed and implemented in a Large Volume Plasma Device (LVPD). The system consists of 12 electro-mechanical assemblies, which are orchestrated using the Modbus communication protocol on 4-wire RS485 communications to meet the experimental requirements. Each assembly has a lead screw-based mechanical structure, Wilson feed-through-based vacuum interface, bipolar stepper motor, micro-controller-based stepper drive, and optical encoder for online positioning correction of probes. The novelty of the system lies in the orchestration of multiple drives on a single interface, fabrication and installation of the system for a large experimental device like the LVPD, in-house developed software, and adopted architectural practices. The paper discusses the design, description of hardware and software interfaces, and performance results in LVPD.

  20. All-mechanical quantum noise cancellation for accelerometry: broadband with momentum measurements, narrow band without

    International Nuclear Information System (INIS)

    Jacobs, Kurt; Balu, Radhakrishnan; Tezak, Nikolas; Mabuchi, Hideo

    2016-01-01

    We show that the ability to make direct measurements of momentum, in addition to the usual direct measurements of position, allows a simple configuration of two identical mechanical oscillators to be used for broadband back-action-free force metrology. This would eliminate the need for an optical reference oscillator in the scheme of Tsang and Caves (2010 Phys. Rev. Lett.  105 123601), along with its associated disadvantages. We also show that if one is restricted to position measurements alone then two copies of the same two-oscillator configuration can be used for narrow-band back-action-free force metrology. (paper)

  1. Technical accuracy of a neuronavigation system measured with a high-precision mechanical micromanipulator.

    Science.gov (United States)

    Kaus, M; Steinmeier, R; Sporer, T; Ganslandt, O; Fahlbusch, R

    1997-12-01

    This study was designed to determine and evaluate the different system-inherent sources of erroneous target localization of a light-emitting diode (LED)-based neuronavigation system (StealthStation, Stealth Technologies, Boulder, CO). The localization accuracy was estimated by applying a high-precision mechanical micromanipulator to move and exactly locate (+/- 0.1 micron) the pointer at multiple positions in the physical three-dimensional space. The localization error was evaluated by calculating the spatial distance between the (known) LED positions and the LED coordinates measured by the neuronavigator. The results are based on a study of approximately 280,000 independent coordinate measurements. The maximum localization error detected was 0.55 +/- 0.29 mm, with the z direction (distance to the camera array) being the most erroneous coordinate. Minimum localization error was found at a distance of 1400 mm from the central camera (optimal measurement position). Additional error due to 1) mechanical vibrations of the camera tripod (+/- 0.15 mm) and the reference frame (+/- 0.08 mm) and 2) extrapolation of the pointer tip position from the LED coordinates of at least +/- 0.12 mm were detected, leading to a total technical error of 0.55 +/- 0.64 mm. Based on this technical accuracy analysis, a set of handling recommendations is proposed, leading to an improved localization accuracy. The localization error could be reduced by 0.3 +/- 0.15 mm by correct camera positioning (1400 mm distance) plus 0.15 mm by vibration-eliminating fixation of the camera. Correct handling of the probe during the operation may improve the accuracy by up to 0.1 mm.

  2. Positive Attitude Toward Math Supports Early Academic Success: Behavioral Evidence and Neurocognitive Mechanisms.

    Science.gov (United States)

    Chen, Lang; Bae, Se Ri; Battista, Christian; Qin, Shaozheng; Chen, Tianwen; Evans, Tanya M; Menon, Vinod

    2018-03-01

    Positive attitude is thought to impact academic achievement and learning in children, but little is known about its underlying neurocognitive mechanisms. Using a large behavioral sample of 240 children, we found that positive attitude toward math uniquely predicted math achievement, even after we accounted for multiple other cognitive-affective factors. We then investigated the neural mechanisms underlying the link between positive attitude and academic achievement in two independent cohorts of children (discovery cohort: n = 47; replication cohort: n = 28) and tested competing hypotheses regarding the differential roles of affective-motivational and learning-memory systems. In both cohorts, we found that positive attitude was associated with increased engagement of the hippocampal learning-memory system. Structural equation modeling further revealed that, in both cohorts, increased hippocampal activity and more frequent use of efficient memory-based strategies mediated the relation between positive attitude and higher math achievement. Our study is the first to elucidate the neurocognitive mechanisms by which positive attitude influences learning and academic achievement.

  3. Optimal leaf positions for chlorophyll meter measurement in rice

    Directory of Open Access Journals (Sweden)

    Zhaofeng eYuan

    2016-05-01

    Full Text Available The Soil Plant Analysis Development (SPAD chlorophyll meter is one of the most commonly used diagnostic tools to measure crop nitrogen status. However, the measurement method of the meter could significantly affect the accuracy of the final estimation. Thus, this research was undertaken to develop a new methodology to optimize SPAD meter measurements in rice (Oryza sativa L.. A flatbed color scanner was used to map the dynamic chlorophyll distribution and irregular leaf shapes. Calculus algorithm was adopted to estimate the potential positions for SPAD meter measurement along the leaf blade. Data generated by the flatbed color scanner and SPAD meter were analysed simultaneously. The results suggested that a position 2/3 of the distance from the leaf base to the apex (2/3 position could represent the chlorophyll content of the entire leaf blade, as indicated by the relatively low variance of measurements at that positon. SPAD values based on di-positional leaves and the extracted chlorophyll a and b contents were compared. This comparison showed that the 2/3 position on the lower leaves tended to be more sensitive to changes in chlorophyll content. Finally, the 2/3 position and average SPAD values of the fourth fully expanded leaf from the top were compared with leaf nitrogen concentration. The results showed the 2/3 position on that leaf was most suitable for predicting the nitrogen status of rice. Based on these results, we recommend making SPAD measurements at the 2/3 position on the fourth fully expanded leaf from the top. The coupling of dynamic chlorophyll distribution and irregular leaf shapes information can provide a promising approach for the calibration of SPAD meter measurement, which can further benefit the in situ nitrogen management by providing reliable estimation of crops nitrogen nutrition status.

  4. Aliasing errors in measurements of beam position and ellipticity

    International Nuclear Information System (INIS)

    Ekdahl, Carl

    2005-01-01

    Beam position monitors (BPMs) are used in accelerators and ion experiments to measure currents, position, and azimuthal asymmetry. These usually consist of discrete arrays of electromagnetic field detectors, with detectors located at several equally spaced azimuthal positions at the beam tube wall. The discrete nature of these arrays introduces systematic errors into the data, independent of uncertainties resulting from signal noise, lack of recording dynamic range, etc. Computer simulations were used to understand and quantify these aliasing errors. If required, aliasing errors can be significantly reduced by employing more than the usual four detectors in the BPMs. These simulations show that the error in measurements of the centroid position of a large beam is indistinguishable from the error in the position of a filament. The simulations also show that aliasing errors in the measurement of beam ellipticity are very large unless the beam is accurately centered. The simulations were used to quantify the aliasing errors in beam parameter measurements during early experiments on the DARHT-II accelerator, demonstrating that they affected the measurements only slightly, if at all

  5. Aliasing errors in measurements of beam position and ellipticity

    Science.gov (United States)

    Ekdahl, Carl

    2005-09-01

    Beam position monitors (BPMs) are used in accelerators and ion experiments to measure currents, position, and azimuthal asymmetry. These usually consist of discrete arrays of electromagnetic field detectors, with detectors located at several equally spaced azimuthal positions at the beam tube wall. The discrete nature of these arrays introduces systematic errors into the data, independent of uncertainties resulting from signal noise, lack of recording dynamic range, etc. Computer simulations were used to understand and quantify these aliasing errors. If required, aliasing errors can be significantly reduced by employing more than the usual four detectors in the BPMs. These simulations show that the error in measurements of the centroid position of a large beam is indistinguishable from the error in the position of a filament. The simulations also show that aliasing errors in the measurement of beam ellipticity are very large unless the beam is accurately centered. The simulations were used to quantify the aliasing errors in beam parameter measurements during early experiments on the DARHT-II accelerator, demonstrating that they affected the measurements only slightly, if at all.

  6. Instrumented Glove Measures Positions Of Fingers

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1993-01-01

    Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.

  7. Applying dual-laser spot positions measurement technology on a two-dimensional tracking measurement system

    International Nuclear Information System (INIS)

    Lee, Hau-Wei; Chen, Chieh-Li

    2009-01-01

    This paper presents a two-dimensional tracking measurement system with a tracking module, which consists of two stepping motors, two laser diodes and a four separated active areas segmented position sensitive detector (PSD). The PSD was placed on a two-dimensional moving stage and used as a tracking target. The two laser diodes in the tracking module were directly rotated to keep the laser spots on the origin of the PSD. The two-dimensional position of the target PSD on the moving stage is determined from the distance between the two motors and the tracking angles of the two laser diodes, which are rotated by the two stepping motors, respectively. In order to separate the four positional values of the two laser spots on one PSD, the laser diodes were modulated by two distinct frequencies. Multiple-laser spot position measurement technology was used to separate the four positional values of the two laser spots on the PSD. The experimental results show that the steady-state voltage shift rate is about 0.2% and dynamic cross-talk rate is smaller than 2% when the two laser spots are projected on one PSD at the same time. The measurement errors of the x and y axial positions of the two-dimensional tracking system were less than 1% in the measuring range of 20 mm. The results demonstrate that multiple-laser spot position measurement technology can be employed in a two-dimensional tracking measurement system

  8. Channel Measurements and Characteristics for Cooperative Positioning Applications

    DEFF Research Database (Denmark)

    Wang, Wei; Steinböck, Gerhard; Jost, Thomas

    2012-01-01

    We have conducted an indoor channel measurement campaign to characterize the propagation channel for the development of cooperative positioning algorithms. The campaign focused particularly on the characteristics of multi-link channels with applications to positioning. In this contribution we...... present the measurement campaign and preliminary results on correlation characteristics of the received power. It is observed that the link-pair log power is uncorrelated. Moreover, the received log power can be modeled by realizations of independent Gaussian distributions for each link, based...... on the measured results....

  9. The role of scalar product and Wigner distribution in optical and quantum mechanical measurements

    International Nuclear Information System (INIS)

    Wodkiewicz, K.

    1984-01-01

    In this paper we present a unified approach to the phase-space description of optical and quantum measurements. We find that from the operational point of view the notion of a time dependent spectrum of light and a joint measurement of position and momentum in quantum mechanics can be formulated in one common approach in which the scalar product, the Wigner function and the phase-space proximity are closely related to a realistic measuring process

  10. The effect of motivation and positive affect on ego depletion: Replenishment versus release mechanism.

    Science.gov (United States)

    Zhu, Ze; Li, Jian; Zhang, Bo; Li, Ye; Zhang, Houcan

    2017-12-01

    In this study, 2 experiments were conducted to investigate whether motivation and positive affect can alleviate ego depletion and to elucidate their possible mechanisms. In Experiment 1, a crossing-out-letter task was adapted to reach an ego depletion state for Chinese participants. Participants were then randomly assigned to the extrinsic motivation group, the positive affect group or the depletion control group. After the experimental treatment, a dumbbell task was used to measure participants' remaining self-regulatory resources. The results showed that participants in the motivation and positive affect groups performed better on the dumbbell task than participants in the depletion control group. Experiment 2 was similar to Experiment 1 except that participants were asked to perform an additional unexpected dumbbell task after a neutral video following the above procedure. The results of Experiment 1 were replicated; however, participants' performance on the additional dumbbell task differed. The positive affect group performed better than the depletion control group, indicating an increase in self-regulatory resources and thus supporting the replenishment effect of positive affect. No significant difference was found between the motivation group and the depletion control group. © 2015 International Union of Psychological Science.

  11. Measuring Mechanical Properties Of Optical Glasses

    Science.gov (United States)

    Tucker, Dennis S.; Nichols, Ronald L.

    1989-01-01

    Report discusses mechanical tests measuring parameters of strength and fracture mechanics of optical glasses. To obtain required tables of mechanical properties of each glass of interest, both initial-strength and delayed-fracture techniques used. Modulus of rupture measured by well-known four-point bending method. Initial bending strength measured by lesser-known double-ring method, in which disk of glass supported on one face near edge by larger ring and pressed on its other face by smaller concentric ring. Method maximizes stress near center, making it more likely specimen fractures there, and thereby suppresses edge effects. Data from tests used to predict reliabilities and lifetimes of glass optical components of several proposed spaceborne instruments.

  12. Nonlinear optomechanical measurement of mechanical motion

    DEFF Research Database (Denmark)

    Brawley, G.A.; Vanner, M R; Larsen, Peter Emil

    2016-01-01

    Precision measurement of nonlinear observables is an important goal in all facets of quantum optics. This allows measurement-based non-classical state preparation, which has been applied to great success in various physical systems, and provides a route for quantum information processing with oth......Precision measurement of nonlinear observables is an important goal in all facets of quantum optics. This allows measurement-based non-classical state preparation, which has been applied to great success in various physical systems, and provides a route for quantum information processing...... with otherwise linear interactions. In cavity optomechanics much progress has been made using linear interactions and measurement, but observation of nonlinear mechanical degrees-of-freedom remains outstanding. Here we report the observation of displacement-squared thermal motion of a micro-mechanical resonator...... by exploiting the intrinsic nonlinearity of the radiation-pressure interaction. Using this measurement we generate bimodal mechanical states of motion with separations and feature sizes well below 100 pm. Future improvements to this approach will allow the preparation of quantum superposition states, which can...

  13. Measures to prevent nosocomial infections during mechanical ventilation.

    Science.gov (United States)

    Ramirez, Paula; Bassi, Gianluigi L; Torres, Antonio

    2012-02-01

    Endotracheal intubation and mechanical ventilation are lifesaving measures in critically ill patients. However, these interventions increase the risk of respiratory infections, particularly ventilator-associated pneumonia (VAP). VAP constitutes a serious burden for the healthcare system and worsens the patient's outcomes; thus, several preventive strategies have been implemented. This communication reviews the current knowledge on VAP pathogenesis and the latest preventive measures. Pathogen-laden oropharyngeal secretions leak across the endotracheal tube (ETT) cuff; thus, a continuous control of the internal cuff pressure and cuffs made of polyurethane improve sealing effectiveness and associated risks of infections. Subglottic secretions aspiration prevents VAP, and the latest evidence demonstrated a reduction in the incidence of late-onset VAP. The role of ETT biofilm in the pathogenesis of VAP is not fully elucidated. Nevertheless, antimicrobial-coated ETTs have showed beneficial effects in VAP incidence. Recent experimental evidence has challenged the benefits associated with the use of the semirecumbent position; yet, these findings need to be corroborated in clinical trials. The latest results from trials testing the effects of selective digestive decontamination (SDD) showed beneficial effects on patients' outcomes, but concerns remain regarding the emergence of bacterial resistance, specifically upon digestive tract re-colonization. The use of oropharyngeal decontamination with antiseptics and the use of probiotics are potential alternatives to SDD. There is consistent evidence that strategies affecting the primary mechanisms of VAP pathogenesis efficiently reduce the occurrence of the disease. Preventive measures should be implemented grouped into bundles to improve overall efficacy.

  14. Quantum mechanics and precision measurements

    International Nuclear Information System (INIS)

    Ramsey, N.F.

    1995-01-01

    The accuracies of measurements of almost all fundamental physical constants have increased by factors of about 10000 during the past 60 years. Although some of the improvements are due to greater care, most are due to new techniques based on quantum mechanics. Although the Heisenberg Uncertainty Principle often limits measurement accuracies, in many cases the validity of quantum mechanics makes possible the vastly improved measurement accuracies. Seven quantum features that have a profound influence on the science of measurements are: 1) Existence of discrete quantum states of energy. 2) Energy conservation in transitions between two states. 3) Electromagnetic radiation of frequency v is quantized with energy hv per quantum. 4) The identity principle. 5) The Heisenberg Uncertainty Principle. 6) Addition of probability amplitudes (not probabilities). 7) Wave and coherent phase phenomena. Of these seven quantum features, only the Heisenberg Uncertainty Principle limits the accuracy of measurements, and its effect is often negligibly small. The other six features make possible much more accurate measurements of quantum systems than with almost all classical systems. These effects are discussed and illustrated

  15. Mechanisms and functions of lysosome positioning

    Science.gov (United States)

    Pu, Jing; Guardia, Carlos M.; Keren-Kaplan, Tal

    2016-01-01

    ABSTRACT Lysosomes have been classically considered terminal degradative organelles, but in recent years they have been found to participate in many other cellular processes, including killing of intracellular pathogens, antigen presentation, plasma membrane repair, cell adhesion and migration, tumor invasion and metastasis, apoptotic cell death, metabolic signaling and gene regulation. In addition, lysosome dysfunction has been shown to underlie not only rare lysosome storage disorders but also more common diseases, such as cancer and neurodegeneration. The involvement of lysosomes in most of these processes is now known to depend on the ability of lysosomes to move throughout the cytoplasm. Here, we review recent findings on the mechanisms that mediate the motility and positioning of lysosomes, and the importance of lysosome dynamics for cell physiology and pathology. PMID:27799357

  16. On-Chip Method to Measure Mechanical Characteristics of a Single Cell by Using Moiré Fringe

    Directory of Open Access Journals (Sweden)

    Hirotaka Sugiura

    2015-06-01

    Full Text Available We propose a method to characterize the mechanical properties of cells using a robot-integrated microfluidic chip (robochip and microscopy. The microfluidic chip is designed to apply the specified deformations to a single detached cell using an on-chip actuator probe. The reaction force is simultaneously measured using an on-chip force sensor composed of a hollow folded beam and probe structure. In order to measure the cellular characteristics in further detail, a sub-pixel level of resolution of probe position is required. Therefore, we utilize the phase detection of moiré fringe. Using this method, the experimental resolution of the probe position reaches 42 nm. This is approximately ten times smaller than the optical wavelength, which is the limit of sharp imaging with a microscope. Calibration of the force sensor is also important in accurately measuring cellular reaction forces. We calibrated the spring constant from the frequency response, by the proposed sensing method of the probe position. As a representative of mechanical characteristics, we measured the elastic modulus of Madin-Darby Cannie Kidney (MDCK cells. In spite of the rigid spring constant, the resolution and sensitivity were twice that achieved in our previous study. Unique cellular characteristics can be elucidated by the improvements in sensing resolution and accuracy.

  17. Subwavelength position measurements with running-wave driving fields

    Energy Technology Data Exchange (ETDEWEB)

    Evers, Joerg [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany); Qamar, Sajid [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany); Centre for Quantum Physics, COMSATS Institute of Information Technology, Islamabad (Pakistan)

    2011-08-15

    Subwavelength position measurement of quantum particles is discussed. Our setup is based on a closed-loop driving-field configuration, which enforces a sensitivity of the particle dynamics to the phases of the applied fields. Thus, running wave fields are sufficient, avoiding limitations associated with standing-wave-based localization schemes. Reversing the directions of the driving laser fields switches between different magnification levels for the position determination. This allows us to optimize the localization, and at the same time eliminates the need for additional classical measurements common to all previous localization schemes based on spatial periodicity.

  18. Noise in position measurement by centroid calculation

    International Nuclear Information System (INIS)

    Volkov, P.

    1996-01-01

    The position of a particle trajectory in a gaseous (or semiconductor) detector can be measured by calculating the centroid of the induced charge on the cathode plane. The charge amplifiers attached to each cathode strip introduce noise which is added to the signal. This noise broadens the position resolution line. Our article gives an analytical tool to estimate the resolution broadening due to the noise per strip and the number of strips involved in the centroid calculation. It is shown that the position resolution increases faster than the square root of the number of strips involved. We also consider the consequence of added interstrip capacitors, intended to diminish the differential nonlinearity. It is shown that the position error increases slower than linearly with the interstrip capacities, due to the cancellation of correlated noise. The estimation we give, can be applied to calculations of position broadening other than the centroid finding. (orig.)

  19. Influence of Marker Movement Errors on Measuring 3 Dimentional Scapular Position and Orientation

    Directory of Open Access Journals (Sweden)

    Afsoun Nodehi-Moghaddam

    2003-12-01

    Full Text Available Objective: Scapulothoracic muscles weakness or fatique can result in abnormal scapular positioning and compromising scapulo-humeral rhythm and shoulder dysfunction .The scapula moves in a -3 Dimentional fashion so the use of 2-Dimentional Techniques cannot fully capture scapular motion . One of approaches to positioining markers of kinematic systems is to mount each marker directly on the skin generally over a bony anatomical landmarks . Howerer skin movement and Motion of underlying bony structures are not Necessaritly identical and substantial errors may be introduced in the description of bone movement when using skin –mounted markers. evaluation of Influence of marker movement errors on 3-Dimentional scapular position and orientation. Materials & Methods: 10 Healthy subjects with a mean age 30.50 participated in the study . They were tested in three sessions A 3-dimentiional electro mechanical digitizer was used to measure scapular position and orientation measures were obtained while arm placed at the side of the body and elevated 45٫90٫120 and full Rang of motion in the scapular plane . At each test positions six bony landmarks were palpated and skin markers were mounted on them . This procedure repeated in the second test session in third session Removal of markers was not performed through obtaining entire Range of motion after mounting the markers . Results: The intraclass correlation coefficients (ICC for scapulor variables were higher (0.92-0.84 when markers were replaced and re-mounted on bony landmarks with Increasing the angle of elevation. Conclusion: our findings suggested significant markers movement error on measuring the upward Rotation and posterior tilt angle of scapula.

  20. Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm

    Directory of Open Access Journals (Sweden)

    Chien-Lun Hou

    2011-02-01

    Full Text Available In this paper, a stereo vision 3D position measurement system for a three-axial pneumatic parallel mechanism robot arm is presented. The stereo vision 3D position measurement system aims to measure the 3D trajectories of the end-effector of the robot arm. To track the end-effector of the robot arm, the circle detection algorithm is used to detect the desired target and the SAD algorithm is used to track the moving target and to search the corresponding target location along the conjugate epipolar line in the stereo pair. After camera calibration, both intrinsic and extrinsic parameters of the stereo rig can be obtained, so images can be rectified according to the camera parameters. Thus, through the epipolar rectification, the stereo matching process is reduced to a horizontal search along the conjugate epipolar line. Finally, 3D trajectories of the end-effector are computed by stereo triangulation. The experimental results show that the stereo vision 3D position measurement system proposed in this paper can successfully track and measure the fifth-order polynomial trajectory and sinusoidal trajectory of the end-effector of the three- axial pneumatic parallel mechanism robot arm.

  1. Responses and mechanisms of positive electron affinity molecules in the N2 mode of the thermionic ionization detector and the electron-capture detector

    International Nuclear Information System (INIS)

    Jones, C.S.

    1989-01-01

    Very little knowledge has been acquired in the past on the mechanistic pathway by which molecules respond in the N 2 mode of the thermionic ionization detector. An attempt is made here to elucidate the response mechanism of the detector. The basic response mechanisms are known for the electron capture detector, and an attempt is made to identify the certain mechanism by which selected molecules respond. The resonance electron capture rate constant has been believed to be temperature independent, and investigations of the temperature dependence of electron capture responses are presented. Mechanisms for the N 2 mode of the thermionic ionization detector have been proposed by examining the detector response to positive electron affinity molecules and by measurement of the ions produced by the detector. Electron capture mechanisms for selected molecules have been proposed by examining their temperature dependent responses in the electron capture detector and negative ion mass spectra of the samples. In studies of the resonance electron capture rate constant, the relative responses of selected positive electron affinity molecules and their temperature dependent responses were investigated. Positive electron affinity did not guarantee large responses in the N 2 mode thermionic ionization detector. High mass ions were measured following ionization of samples in the detector. Responses in the electron capture detector varied with temperature and electron affinity

  2. Development of a mechanical model to analysis motion of standing up from the sitting position

    Directory of Open Access Journals (Sweden)

    Kasım Serbest

    2013-08-01

    Full Text Available In this study, a human body has been composed as a 6 rigid-open loop-body model which is consisted of a leg, a foot, a thigh, a trunk, an arm and a fore arm. To determine the anthropometric characteristics of the bodies has been benefited from anthropometric models and the computer software. The movements of the subject markers placed on body was viewed with a video camera in order to get location data of joints and the digitization process was made. It was computed the angular displacement, angular velocity and angular acceleration of the joints using by MATLAB (7.6.0. The obtained data was used to actuate inverse dynamics model which is created by SimMechanics (2.7.1.Motion of standing up from the sitting position was simulated by using SimMechanics software. It was compared ground reaction force calculated by SimMechanics with ground reaction force measured by force platform. This study was also shown that SimMechanics software which is developed to analyse mechanical systems in real dimensions dynamically can be used for human motion analysis. Furthermore, the simulating process has been useful to explain kinetic behaviour of the human movement.

  3. A setup for measurement of beam stability and position using position sensitive detector for Indus-1

    International Nuclear Information System (INIS)

    Nathwani, R.K.; Joshi, D.K.; Tyagi, Y.; Soni, R.S.; Puntambekar, T.A.; Pithawa, C.K.

    2009-01-01

    The 450 MeV electron synchrotron radiation source Indus-1 is operational at RRCAT. A set-up has been developed to measure the relative transverse positional stability of the electron beam and its position with microns resolution using position sensitive photodiodes. The set-up has been installed at the diagnostics beam line of Indus-1. Synchrotron light from photo physics beamline was reflected out by inserting a Ni coated mirror and was focused onto a duo-lateral position sensitive photodiode by using two mirrors of 1.25 meter focal length to obtain unity magnification. The set-up consists of a duo-lateral position sensitive detector (PSD), precision processing electronics and a PC based data acquisition system. A computer program captures the processed signals on to a PC using GPIB interface and displays vertical position of the beam in real time. The paper describes the salient features of the setup developed for measurement of beam stability. (author)

  4. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  5. Application of digital beam position processor Libera on tune measurement

    International Nuclear Information System (INIS)

    Zhang Chunhui; Sun Baogen; Cao Yong; Lu Ping; Li Jihao

    2006-01-01

    Digital signal processing (DSP) is widely used in the field of beam diagnostics. Especially, DSP achieves very good performance in beam position signal analysis and betatron tune measurement. In Hefei light source, when beam was excited by narrow-band Gaussian white nose, Libera, a digital beam position processor, was used to process the signals from beam position monitor (BPM), which contained betatron oscillation. Fast Fourier transform (FFT) was applied to finding out betatron resonance frequency, from which the decimal part of betatron oscillation tune was calculated. By this means, the measure of horizontal tune was 3.5352 and the measure of vertical tune is 2.6299. (authors)

  6. Control of Pan-tilt Mechanism Angle using Position Matrix Method

    Directory of Open Access Journals (Sweden)

    Hendri Maja Saputra

    2013-12-01

    Full Text Available Control of a Pan-Tilt Mechanism (PTM angle for the bomb disposal robot Morolipi-V2 using inertial sensor measurement unit, x-IMU, has been done. The PTM has to be able to be actively controlled both manually and automatically in order to correct the orientation of the moving Morolipi-V2 platform. The x-IMU detects the platform orientation and sends the result in order to automatically control the PTM. The orientation is calculated using the quaternion combined with Madwick and Mahony filter methods. The orientation data that consists of angles of roll (α, pitch (β, and yaw (γ from the x-IMU are then being sent to the camera for controlling the PTM motion (pan & tilt angles after calculating the reverse angle using position matrix method. Experiment results using Madwick and Mahony methods show that the x-IMU can be used to find the robot platform orientation. Acceleration data from accelerometer and flux from magnetometer produce noise with standard deviation of 0.015 g and 0.006 G, respectively. Maximum absolute errors caused by Madgwick and Mahony method with respect to Xaxis are 48.45º and 33.91º, respectively. The x-IMU implementation as inertia sensor to control the Pan-Tilt Mechanism shows a good result, which the probability of pan angle tends to be the same with yaw and tilt angle equal to the pitch angle, except a very small angle shift due to the influence of roll angle..

  7. Compensation for positioning error of industrial robot for flexible vision measuring system

    Science.gov (United States)

    Guo, Lei; Liang, Yajun; Song, Jincheng; Sun, Zengyu; Zhu, Jigui

    2013-01-01

    Positioning error of robot is a main factor of accuracy of flexible coordinate measuring system which consists of universal industrial robot and visual sensor. Present compensation methods for positioning error based on kinematic model of robot have a significant limitation that it isn't effective in the whole measuring space. A new compensation method for positioning error of robot based on vision measuring technique is presented. One approach is setting global control points in measured field and attaching an orientation camera to vision sensor. Then global control points are measured by orientation camera to calculate the transformation relation from the current position of sensor system to global coordinate system and positioning error of robot is compensated. Another approach is setting control points on vision sensor and two large field cameras behind the sensor. Then the three dimensional coordinates of control points are measured and the pose and position of sensor is calculated real-timely. Experiment result shows the RMS of spatial positioning is 3.422mm by single camera and 0.031mm by dual cameras. Conclusion is arithmetic of single camera method needs to be improved for higher accuracy and accuracy of dual cameras method is applicable.

  8. Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.

    Science.gov (United States)

    Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther

    2017-07-01

    Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.

  9. Compact very low temperature scanning tunneling microscope with mechanically driven horizontal linear positioning stage.

    Science.gov (United States)

    Suderow, H; Guillamon, I; Vieira, S

    2011-03-01

    We describe a scanning tunneling microscope for operation in a dilution refrigerator with a sample stage which can be moved macroscopically in a range up to a cm and with an accuracy down to the tens of nm. The position of the tip over the sample as set at room temperature does not change more than a few micrometers when cooling down. This feature is particularly interesting for work on micrometer sized samples. Nanostructures can be also localized and studied, provided they are repeated over micrometer sized areas. The same stage can be used to approach a hard single crystalline sample to a knife and cleave it, or break it, in situ. In situ positioning is demonstrated with measurements at 0.1 K in nanofabricated samples. Atomic resolution down to 0.1 K and in magnetic fields of 8 T is demonstrated in NbSe(2). No heat dissipation nor an increase in mechanical noise has been observed at 0.1 K when operating the slider.

  10. From joint implementation to a clean development mechanism : Have the African positions changed?

    International Nuclear Information System (INIS)

    Thomas, J.P.

    1998-01-01

    The economic and political implications of the applications of the Kyoto United Nations Framework Conference on Climate Change for African developing nations were discussed. The concepts of joint implementation, clean development mechanism, and ecological implications were presented. Also discussed were the African positions on these matters, and on the mechanism of Article 12 of the Kyoto protocol (the Clean Development Mechanism). 19 refs., 1 tab

  11. Quantum mechanics and the science of measurements

    International Nuclear Information System (INIS)

    Ramsey, N.F.

    1992-01-01

    The accuracies of measurements of almost all fundamental physical constants have increased by factors of about 10,000 during the past 60 years. Although some of the improvements are due to greater care, most are due to new techniques based on quantum mechanics. In popular accounts of quantum mechanics, such great emphases is placed on the Heisenberg Uncertainty Principle that it often appears that the primary effect of quantum mechanics should be to diminish measurement accuracy whereas in most cases it is the validity of quantum mechanics that makes possible the vastly improved measurement accuracies. Seven quantum features that have a profound influence on the science of measurements are: (1) Existence of discrete quantum states of energy W i . (2) Energy conservation in transitions between two states. (3) Electromagnetic radiation of frequency ν is quantized with energy hν per quantum. (4) The identity principle. (5) The Heisenberg Uncertainty Principle. (6) Addition of probability amplitudes (not probabilities) so P=vertical strokeψ 1 +ψ 2 vertical stroke 2 ≠vertical strokeψ 1 vertical stroke 2 +vertical strokeψ 2 vertical stroke 2 . (7) Wave and coherent phase phenomena. Of these seven quantum features, only the Heisenberg Uncertainty Principle limits the accuracy of measurements, and its affect is often negligibly small. The other six features make possible much more accurate measurements of quantum systems than with almost all classical systems and the identity principle provides meaning and significance to highly precise measurements with quantized systems. These effects are discussed and illustrated. (orig.)

  12. Measurement theory in quantum mechanics

    International Nuclear Information System (INIS)

    Klein, G.

    1980-01-01

    It is assumed that consciousness, memory and liberty (within the limits of the quantum mechanics indeterminism) are fundamental properties of elementary particles. Then, using this assumption it is shown how measurements and observers may be introduced in a natural way in the quantum mechanics theory. There are no longer fundamental differences between macroscopic and microscopic objects, between classical and quantum objects, between observer and object. Thus, discrepancies and paradoxes have disappeared from the conventional quantum mechanics theory. One consequence of the cumulative memory of the particles is that the sum of negentropy plus information is a constant. Using this theory it is also possible to explain the 'paranormal' phenomena and what is their difference from the 'normal' ones [fr

  13. Comparison between conventional protective mechanical ventilation and high-frequency oscillatory ventilation associated with the prone position.

    Science.gov (United States)

    Fioretto, José Roberto; Klefens, Susiane Oliveira; Pires, Rafaelle Fernandes; Kurokawa, Cilmery Suemi; Carpi, Mario Ferreira; Bonatto, Rossano César; Moraes, Marcos Aurélio; Ronchi, Carlos Fernando

    2017-01-01

    To compare the effects of high-frequency oscillatory ventilation and conventional protective mechanical ventilation associated with the prone position on oxygenation, histology and pulmonary oxidative damage in an experimental model of acute lung injury. Forty-five rabbits with tracheostomy and vascular access were underwent mechanical ventilation. Acute lung injury was induced by tracheal infusion of warm saline. Three experimental groups were formed: healthy animals + conventional protective mechanical ventilation, supine position (Control Group; n = 15); animals with acute lung injury + conventional protective mechanical ventilation, prone position (CMVG; n = 15); and animals with acute lung injury + high-frequency oscillatory ventilation, prone position (HFOG; n = 15). Ten minutes after the beginning of the specific ventilation of each group, arterial gasometry was collected, with this timepoint being called time zero, after which the animal was placed in prone position and remained in this position for 4 hours. Oxidative stress was evaluated by the total antioxidant performance assay. Pulmonary tissue injury was determined by histopathological score. The level of significance was 5%. Both groups with acute lung injury showed worsening of oxygenation after induction of injury compared with the Control Group. After 4 hours, there was a significant improvement in oxygenation in the HFOG group compared with CMVG. Analysis of total antioxidant performance in plasma showed greater protection in HFOG. HFOG had a lower histopathological lesion score in lung tissue than CMVG. High-frequency oscillatory ventilation, associated with prone position, improves oxygenation and attenuates oxidative damage and histopathological lung injury compared with conventional protective mechanical ventilation.

  14. Effects of recruitment maneuver and positive end-expiratory pressure on respiratory mechanics and transpulmonary pressure during laparoscopic surgery.

    Science.gov (United States)

    Cinnella, Gilda; Grasso, Salvatore; Spadaro, Savino; Rauseo, Michela; Mirabella, Lucia; Salatto, Potito; De Capraris, Antonella; Nappi, Luigi; Greco, Pantaleo; Dambrosio, Michele

    2013-01-01

    The authors tested the hypothesis that during laparoscopic surgery, Trendelenburg position and pneumoperitoneum may worsen chest wall elastance, concomitantly decreasing transpulmonary pressure, and that a protective ventilator strategy applied after pneumoperitoneum induction, by increasing transpulmonary pressure, would result in alveolar recruitment and improvement in respiratory mechanics and gas exchange. In 29 consecutive patients, a recruiting maneuver followed by positive end-expiratory pressure 5 cm H(2)O maintained until the end of surgery was applied after pneumoperitoneum induction. Respiratory mechanics, gas exchange, blood pressure, and cardiac index were measured before (T(BSL)) and after pneumoperitoneum with zero positive end-expiratory pressure (T(preOLS)), after recruitment with positive end-expiratory pressure (T(postOLS)), and after peritoneum desufflation with positive end-expiratory pressure (T(end)). Esophageal pressure was used for partitioning respiratory mechanics between lung and chest wall (data are mean ± SD): on T(preOLS), chest wall elastance (E(cw)) and elastance of the lung (E(L)) increased (8.2 ± 0.9 vs. 6.2 ± 1.2 cm H(2)O/L, respectively, on T(BSL); P = 0.00016; and 11.69 ± 1.68 vs. 9.61 ± 1.52 cm H(2)O/L on T(BSL); P = 0.0007). On T(postOLS), both chest wall elastance and E(L) decreased (5.2 ± 1.2 and 8.62 ± 1.03 cm H(2)O/L, respectively; P = 0.00015 vs. T(preOLS)), and Pao(2)/inspiratory oxygen fraction improved (491 ± 107 vs. 425 ± 97 on T(preOLS); P = 0.008) remaining stable thereafter. Recruited volume (the difference in lung volume for the same static airway pressure) was 194 ± 80 ml. Pplat(RS) remained stable while inspiratory transpulmonary pressure increased (11.65 + 1.37 cm H(2)O vs. 9.21 + 2.03 on T(preOLS); P = 0.007). All respiratory mechanics parameters remained stable after abdominal desufflation. Hemodynamic parameters remained stable throughout the study. In patients submitted to laparoscopic surgery in

  15. Development of position measuring technology by GPS; GPS ni yoru sokui gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Ishizaki, T [Ministry of Transportation, Tokyo (Japan)

    1994-07-25

    With regard to the GPS (global positioning system) which uses the satellites launched and administered by the U.S.A. and has been utilized worldwide for ships, automobiles and geodetic surveys in recent years, Ministry of Transport started investigation and research on the application of its position measuring system from FY 1989. In this fiscal year, a study on position measuring methods and selection of the position measuring system to be developed were made, in FY 1991, the real-time functioning and track display were developed, in FY 1992, the initialization aboard the ship, the measure to prevent cycle slip, and the radio data communication technology were developed, and in FY 1993, a long term demonstration experiment presuming its practical use was conducted attaining the expected purpose. In this article, the developed real-time kinematic position measuring system is introduced. Regarding the position measuring methods by the GPS, there are the one point position measuring method and the relative position measuring method. Regarding this newly developed position measuring device, its application to work ships and structures can be considered in various ways. 4 figs.

  16. LHC Collimators with Embedded Beam Position Monitors: a New Adbanced Mechanical Design

    CERN Document Server

    Dallocchio, A; Boccard, C; Carra, F; Gasior, M; Gentini, L; Timmins, M

    2011-01-01

    The LHC collimation system, ensuring both functions of beam cleaning and machine protection, is potentially submitted to high-energy beam impacts. Currently the collimators setup is performed by monitoring beam losses generated by the collimator jaws when approaching the particle beam. This procedure is applied to all LHC collimators (almost one hundred), taking several hours, and needs to be repeated if beam settings change significantly. Furthermore, during the beam-based alignment, the LHC tertiary collimators are potentially exposed to abnormal losses entailing possible damage to their tungsten jaws. To improve the efficiency of the machine operation and better control the particle beam a new advanced design embedding Beam Position Monitors (BPM) into the movable collimator jaws has been developed. This paper describes the mechanical design of various types of future collimators with embedded BPMs. Experimental measurements performed on a simplified functional prototype installed in the CERN SPS showed th...

  17. LHC Collimators with Embedded Beam Position Monitors: A New Advanced Mechanical Design

    CERN Document Server

    Dallocchio, A; Boccard, C; Carra, F; Gasior, M; Gentini, L; Timmins, M A

    2011-01-01

    The LHC collimation system, ensuring both functions of beam cleaning and machine protection, is potentially submitted to high-energy beam impacts. Currently the collimators setup is performed by monitoring beam losses generated by the collimator jaws when approaching the particle beam. This procedure is applied to all LHC collimators (almost one hundred), taking several hours, and needs to be repeated if beam settings change significantly. Furthermore, during the beam-based alignment, the LHC tertiary collimators are potentially exposed to abnormal losses entailing possible damage to their tungsten jaws. To improve the efficiency of the machine operation and better control the particle beam a new advanced design embedding Beam Position Monitors (BPM) into the movable collimator jaws has been developed. This paper describes the mechanical design of various types of future collimators with embedded BPMs. Experimental measurements performed on a simplified functional prototype installed in the CERN SPS showed th...

  18. A position-sensitive start detector for time-of-flight measurement

    International Nuclear Information System (INIS)

    Ikezoe, Hiroshi; Shikazono, Naomoto; Isoyama, Goro.

    1978-08-01

    A position-sensitive start detector for a time-of-flight measurement is described. In this detector microchannel plates were used to obtain time and position signals simultaneously. A time resolution of 121 psec FWHM and a position resolution of 0.28 mm FWHM were obtained for α-particles from an 241 Am source. (auth.)

  19. Focused-laser interferometric position sensor

    International Nuclear Information System (INIS)

    Friedman, Stephen J.; Barwick, Brett; Batelaan, Herman

    2005-01-01

    We describe a simple method to measure the position shifts of an object with a range of tens of micrometers using a focused-laser (FL) interferometric position sensor. In this article we examine the effects of mechanical vibration on FL and Michelson interferometers. We tested both interferometers using vibration amplitudes ranging from 0 to 20 μm. Our FL interferometer has a resolution much better than the diffraction grating periodicities of 10 and 14 μm used in our experiments. A FL interferometer provides improved mechanical stability at the expense of spatial resolution. Our experimental results show that Michelson interferometers cannot be used when the vibration amplitude is more than an optical wavelength. The main purpose of this article is to demonstrate that a focused-laser interferometric position sensor can be used to measure the position shifts of an object on a less sensitive, micrometer scale when the vibration amplitude is too large to use a Michelson interferometer

  20. Design and operation of a button-probe, beam-position measurements

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Power, J.F.; Meyer, R.E.; Rose, C.R.

    1993-01-01

    Beam position measurement systems have been installed on the Advanced Free Electron Laser (AFEL) facility at Los Alamos National Laboratory. The position measurement uses a capacitive- or button-style probe that differentiates the beam-bunch charge distribution induced on each of the four probe lobes. These induced signals are fed to amplitude-to-phase processing electronics that provide output signals proportional to the arc tangent of the probe's opposite-lobe, signal-voltage ratios. An associated computer system then digitizes and linearizes these processed signals based on theoretical models and measured responses. This paper will review the processing electronics and capacitive probe responses by deriving simple theoretical models and comparing these models to actual measured responses

  1. Effect of non-identity of beam position monitors manufacturing on measurement accuracy of the reference orbit coordinates

    International Nuclear Information System (INIS)

    Ivashchenko, V.E.; Karnaukhov, I.M.; Trotsenko, V.I.; Shcherbakov, A.A.

    2007-01-01

    Effect of geometrical and electrical non-identity of monitors manufacturing on accuracy of measurement of beam position has been studied. It has been shown, that even providing mechanical accuracy of monitor manufacturing of about ±100 μm and deviation of electric capacity of electrodes equal to ±2%, their operating characteristics near the monitor center may differ from each other more than on ±300 μm

  2. Noninvasive Positive Pressure Ventilation or Conventional Mechanical Ventilation for Neonatal Continuous Positive Airway Pressure Failure

    Directory of Open Access Journals (Sweden)

    Zohreh Badiee

    2014-01-01

    Full Text Available Background: The aim of this study was to assess the success rate of nasal intermittent positive pressure ventilation (NIPPV for treatment of continuous positive airway pressure (CPAP failure and prevention of conventional ventilation (CV in preterm neonates. Methods: Since November 2012 to April 2013, a total number of 55 consecutive newborns with gestational ages of 26-35 weeks who had CPAP failure were randomly assigned to one of the two groups. The NIPPV group received NIPPV with the initial peak inspiratory pressure (PIP of 16-20 cmH 2 O and frequency of 40-60 breaths/min. The CV group received PIP of 12-20 cmH 2 O and frequency of 40-60 breaths/min. Results: About 74% of newborns who received NIPPV for management of CPAP failure responded to NIPPV and did not need intubation and mechanical ventilation. Newborns with lower postnatal age at entry to the study and lower 5 min Apgar score more likely had NIPPV failure. In addition, treatment failure was higher in newborns who needed more frequent doses of surfactant. Duration of oxygen therapy was 9.28 days in CV group and 7.77 days in NIPPV group (P = 0.050. Length of hospital stay in CV group and NIPPV groups were 48.7 and 41.7 days, respectively (P = 0.097. Conclusions: NIPPV could decrease the need for intubation and mechanical ventilation in preterm infants with CPAP failure.

  3. Development of position measurement unit for flying inertial fusion energy target

    International Nuclear Information System (INIS)

    Tsuji, R; Endo, T; Yoshida, H; Norimatsu, T

    2016-01-01

    We have reported the present status in the development of a position measurement unit (PMU) for a flying inertial fusion energy (IFE) target. The PMU, which uses Arago spot phenomena, is designed to have a measurement accuracy smaller than 1 μm. By employing divergent, pulsed orthogonal laser beam illumination, we can measure the time and the target position at the pulsed illumination. The two-dimensional Arago spot image is compressed into one-dimensional image by a cylindrical lens for real-time processing. The PMU are set along the injection path of the flying target. The local positions of the target in each PMU are transferred to the controller and analysed to calculate the target trajectory. Two methods are presented to calculate the arrival time and the arrival position of the target at the reactor centre. (paper)

  4. Development of position measurement unit for flying inertial fusion energy target

    Science.gov (United States)

    Tsuji, R.; Endo, T.; Yoshida, H.; Norimatsu, T.

    2016-03-01

    We have reported the present status in the development of a position measurement unit (PMU) for a flying inertial fusion energy (IFE) target. The PMU, which uses Arago spot phenomena, is designed to have a measurement accuracy smaller than 1 μm. By employing divergent, pulsed orthogonal laser beam illumination, we can measure the time and the target position at the pulsed illumination. The two-dimensional Arago spot image is compressed into one-dimensional image by a cylindrical lens for real-time processing. The PMU are set along the injection path of the flying target. The local positions of the target in each PMU are transferred to the controller and analysed to calculate the target trajectory. Two methods are presented to calculate the arrival time and the arrival position of the target at the reactor centre.

  5. Reproducibility analysis of measurements with a mechanical semiautomatic eye model for evaluation of intraocular lenses

    Science.gov (United States)

    Rank, Elisabet; Traxler, Lukas; Bayer, Natascha; Reutterer, Bernd; Lux, Kirsten; Drauschke, Andreas

    2014-03-01

    Mechanical eye models are used to validate ex vivo the optical quality of intraocular lenses (IOLs). The quality measurement and test instructions for IOLs are defined in the ISO 11979-2. However, it was mentioned in literature that these test instructions could lead to inaccurate measurements in case of some modern IOL designs. Reproducibility of alignment and measurement processes are presented, performed with a semiautomatic mechanical ex vivo eye model based on optical properties published by Liou and Brennan in the scale 1:1. The cornea, the iris aperture and the IOL itself are separately changeable within the eye model. The adjustment of the IOL can be manipulated by automatic decentration and tilt of the IOL in reference to the optical axis of the whole system, which is defined by the connection line of the central point of the artificial cornea and the iris aperture. With the presented measurement setup two quality criteria are measurable: the modulation transfer function (MTF) and the Strehl ratio. First the reproducibility of the alignment process for definition of initial conditions of the lateral position and tilt in reference to the optical axis of the system is investigated. Furthermore, different IOL holders are tested related to the stable holding of the IOL. The measurement is performed by a before-after comparison of the lens position using a typical decentration and tilt tolerance analysis path. Modulation transfer function MTF and Strehl ratio S before and after this tolerance analysis are compared and requirements for lens holder construction are deduced from the presented results.

  6. A method for measuring plasma position in the rectangular tokamak TJ-I

    International Nuclear Information System (INIS)

    Qin, J.; Ascasibar, E.; Pastor, I.; Navarro, A.P.; Ochando, M.A.; Pedrosa, M.A.; Rodriguez, L.; Sanchez, J.

    1993-01-01

    Determinations of plasma position in tokamaks are based on measuring the external magnetic field of the plasma current. Usually, the measurements are performed with magnetic coils along a closed contour around the plasma column, or with small magnetic probes in pairs positioned diametrically. However, such measurements are constrained in TJ-I because of a severe restriction on installing the magnetic probes. It is only possible to install some small magnetic probes inside the vacuum vessel near its top and bottom walls where the limiters stand. In this paper an alternative method of measuring plasma position in TJ-I is presented. The plasma position can be derived from the measurements of those magnetic probes located off the equatorial plane, with the aid of a filament model. The method is proved to be reliable, and would be applied to those small-size devices with similar restrictions. (author) 5 refs., 3 figs., 1 tab

  7. Improvement of CD-SEM mark position measurement accuracy

    Science.gov (United States)

    Kasa, Kentaro; Fukuhara, Kazuya

    2014-04-01

    CD-SEM is now attracting attention as a tool that can accurately measure positional error of device patterns. However, the measurement accuracy can get worse due to pattern asymmetry as in the case of image based overlay (IBO) and diffraction based overlay (DBO). For IBO and DBO, a way of correcting the inaccuracy arising from measurement patterns was suggested. For CD-SEM, although a way of correcting CD bias was proposed, it has not been argued how to correct the inaccuracy arising from pattern asymmetry using CD-SEM. In this study we will propose how to quantify and correct the measurement inaccuracy affected by pattern asymmetry.

  8. Bohmian mechanics, open quantum systems and continuous measurements

    CERN Document Server

    Nassar, Antonio B

    2017-01-01

    This book shows how Bohmian mechanics overcomes the need for a measurement postulate involving wave function collapse. The measuring process plays a very important role in quantum mechanics. It has been widely analyzed within the Copenhagen approach through the Born and von Neumann postulates, with later extension due to Lüders. In contrast, much less effort has been invested in the measurement theory within the Bohmian mechanics framework. The continuous measurement (sharp and fuzzy, or strong and weak) problem is considered here in this framework. The authors begin by generalizing the so-called Mensky approach, which is based on restricted path integral through quantum corridors. The measuring system is then considered to be an open quantum system following a stochastic Schrödinger equation. Quantum stochastic trajectories (in the Bohmian sense) and their role in basic quantum processes are discussed in detail. The decoherence process is thereby described in terms of classical trajectories issuing from th...

  9. A laser interferometer for measuring straightness and its position based on heterodyne interferometry

    International Nuclear Information System (INIS)

    Chen Benyong; Zhang Enzheng; Yan Liping; Li Chaorong; Tang Wuhua; Feng Qibo

    2009-01-01

    Not only the magnitude but also the position of straightness errors are of concern to users. However, current laser interferometers used for measuring straightness seldom give the relative position of the straightness error. To solve this problem, a laser interferometer for measuring straightness and its position based on heterodyne interferometry is proposed. The optical configuration of the interferometer is designed and the measurement principle is analyzed theoretically. Two experiments were carried out. The first experiment verifies the validity and repeatability of the interferometer by measuring a linear stage. Also, the second one for measuring a flexure-hinge stage demonstrates that the interferometer is capable of nanometer measurement accuracy. These results show that this interferometer has advantages of simultaneously measuring straightness error and the relative position with high precision, and a compact structure.

  10. Plasma position from ring current measurements in Extrap T1

    International Nuclear Information System (INIS)

    Brunsell, P.; Jin Li.

    1989-11-01

    The inductive coupling between the plasma and the four octupole field coils in the Extrap T1 device is utilized as a means of estimating the plasma position. The current in each octupole ring as well as the plasma current is measured by a Rogowski coil and the ring - plasma mutual inductance is then computed assuming axisymmetric plasma displacements. The obtained position is in agreement with internal magnetic probe measurements. The time - evolution of the plasma position for different external vertical and toroidal field strengths is studied. For the present discharge parameter a vertical field of about .008 T is found to give an almost radially stationary plasma. The results are compared with a simple equilibrium model

  11. Positive-operator-valued measure optimization of classical correlations

    NARCIS (Netherlands)

    Hamieh, S; Kobes, R; Zaraket, H

    We study the problem of optimization over positive-operator-valued measures to extract classical correlation in a bipartite quantum system. The proposed method is applied to binary states only. Moreover, to illustrate this method, an explicit example is studied in detail.

  12. Beam based measurement of beam position monitor electrode gains

    Directory of Open Access Journals (Sweden)

    D. L. Rubin

    2010-09-01

    Full Text Available Low emittance tuning at the Cornell Electron Storage Ring (CESR test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ∼0.1%.

  13. Beam based measurement of beam position monitor electrode gains

    Science.gov (United States)

    Rubin, D. L.; Billing, M.; Meller, R.; Palmer, M.; Rendina, M.; Rider, N.; Sagan, D.; Shanks, J.; Strohman, C.

    2010-09-01

    Low emittance tuning at the Cornell Electron Storage Ring (CESR) test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs) consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ˜0.1%.

  14. Evaluation of two methods of predicting MLC leaf positions using EPID measurements

    International Nuclear Information System (INIS)

    Parent, Laure; Seco, Joao; Evans, Phil M.; Dance, David R.; Fielding, Andrew

    2006-01-01

    In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positions. Thereafter leaf positions of the MLC depend on the systematic error introduced on each leaf during MLC calibration and on the accuracy of the leaf position control system (random errors). This study presents and evaluates two methods to predict the systematic errors on the leaf positions introduced during the MLC calibration. The two presented methods are based on a series of electronic portal imaging device (EPID) measurements. A comparison with film measurements showed that the EPID could be used to measure leaf positions without introducing any bias. The first method, referred to as the 'central leaf method', is based on the method currently used at this center for MLC leaf calibration. It mimics the manner in which leaf calibration parameters are specified in the MLC control system and consequently is also used by other centers. The second method, a new method proposed by the authors and referred to as the ''individual leaf method,'' involves the measurement of two positions for each leaf (-5 and +15 cm) and the interpolation and extrapolation from these two points to any other given position. The central leaf method and the individual leaf method predicted leaf positions at prescribed positions of -11, 0, 5, and 10 cm within 2.3 and 1.0 mm, respectively, with a standard deviation (SD) of 0.3 and 0.2 mm, respectively. The individual leaf method provided a better prediction of the leaf positions than the central leaf method. Reproducibility tests for leaf positions of -5 and +15 cm were performed. The reproducibility was within 0.4 mm on the same day and 0.4 mm six weeks later (1 SD). Measurements at gantry angles of 0 deg., 90 deg., and 270 deg

  15. Numerical Simulation and Mechanical Design for TPS Electron Beam Position Monitors

    Science.gov (United States)

    Hsueh, H. P.; Kuan, C. K.; Ueng, T. S.; Hsiung, G. Y.; Chen, J. R.

    2007-01-01

    Comprehensive study on the mechanical design and numerical simulation for the high resolution electron beam position monitors are key steps to build the newly proposed 3rd generation synchrotron radiation research facility, Taiwan Photon Source (TPS). With more advanced electromagnetic simulation tool like MAFIA tailored specifically for particle accelerator, the design for the high resolution electron beam position monitors can be tested in such environment before they are experimentally tested. The design goal of our high resolution electron beam position monitors is to get the best resolution through sensitivity and signal optimization. The definitions and differences between resolution and sensitivity of electron beam position monitors will be explained. The design consideration is also explained. Prototype deign has been carried out and the related simulations were also carried out with MAFIA. The results are presented here. Sensitivity as high as 200 in x direction has been achieved in x direction at 500 MHz.

  16. Numerical Simulation and Mechanical Design for TPS Electron Beam Position Monitors

    International Nuclear Information System (INIS)

    Hsueh, H. P.; Kuan, C. K.; Ueng, T. S.; Hsiung, G. Y.; Chen, J. R.

    2007-01-01

    Comprehensive study on the mechanical design and numerical simulation for the high resolution electron beam position monitors are key steps to build the newly proposed 3rd generation synchrotron radiation research facility, Taiwan Photon Source (TPS). With more advanced electromagnetic simulation tool like MAFIA tailored specifically for particle accelerator, the design for the high resolution electron beam position monitors can be tested in such environment before they are experimentally tested. The design goal of our high resolution electron beam position monitors is to get the best resolution through sensitivity and signal optimization. The definitions and differences between resolution and sensitivity of electron beam position monitors will be explained. The design consideration is also explained. Prototype deign has been carried out and the related simulations were also carried out with MAFIA. The results are presented here. Sensitivity as high as 200 in x direction has been achieved in x direction at 500 MHz

  17. Study on AE in Mechanical Seal Lift-off Recognition of Mechanical Main Shaft

    Directory of Open Access Journals (Sweden)

    Erqing Zhang

    2014-06-01

    Full Text Available For the problem of the determination of lift-off position and the measurement of end face thickness for mechanical seal more difficult, the method based on acoustic emission signal end face lift-off condition monitoring technology for mechanical seal was proposed. The electric eddy current sensor made direct measurement in the internal of mechanical seal device, and the acoustic emission sensor was fixed in the outside for indirect measurement. The acoustic emission signals were de-noised by wavelet threshold de-noising method. The representative energy features were selected by wavelet packet energy spectrum algorithm. It was established that the Radial Basis Function neural network model used for identification of the mechanical seal lift-off position, and the extracted wavelet energy features as its input. It was confirmed accurate and effective that the acoustic emission identification technology through comparing with the data detected by electric eddy current sensor. So using the acoustic emission technology realized the identification of the mechanical seal lift-off position of mechanical main shaft from inside to outside. It is convenient to be used and promotion in industrial field.

  18. Approach to measurement to quantum mechanics

    International Nuclear Information System (INIS)

    Sudarshan, E.C.G.; Sherry, T.N.; Gautam, S.R.

    1977-10-01

    An unconventional approach to the measurement problem in quantum mechanics is considered, the apparatus is treated as a classical system, belonging to the macro-world. In order to have a measurement the apparatus must interact with the quantum system. As a first step, the classical apparatus is embedded into a larger quantum mechanical structure, making use of superselection rules. Projection back to the classical system is possible. The apparatus and system are now coupled such that the apparatus remains classical (principle of integrity), and unambiguous information of the values of a quantum observable are transferred to the variables of the apparatus. Finally, projection back to the classical formulation is accomplished. Further measurement of the classical apparatus can be done, causing no problems of principle. Thus interactions causing pointers to move (which are not treat) can be added. The restrictions placed by the principle of integrity on the form of the interaction between classical and quantum systems are examined

  19. Toward quantum-limited position measurements using optically levitated microspheres

    International Nuclear Information System (INIS)

    Libbrecht, Kenneth G.; Black, Eric D.

    2004-01-01

    We propose the use of optically levitated microspheres as test masses in experiments aimed at reaching and potentially exceeding the standard quantum limit for position measurements. Optically levitated microspheres have low mass and are essentially free of suspension thermal noise, making them well suited for experimentally testing our understanding of quantum-limited measurements

  20. Toward quantum-limited position measurements using optically levitated microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Libbrecht, Kenneth G.; Black, Eric D

    2004-01-26

    We propose the use of optically levitated microspheres as test masses in experiments aimed at reaching and potentially exceeding the standard quantum limit for position measurements. Optically levitated microspheres have low mass and are essentially free of suspension thermal noise, making them well suited for experimentally testing our understanding of quantum-limited measurements.

  1. Effects of the positioning force of electrostatic levitators on viscosity measurements

    International Nuclear Information System (INIS)

    Ishikawa, Takehiko; Paradis, Paul-Francois; Koike, Noriyuki; Watanabe, Yuki

    2009-01-01

    Electrostatic levitators use strong electric fields to levitate and accurately position a sample against gravity. In this study, the effects of the electric field are investigated with regard to viscosity measurements conducted with the oscillating drop method. The effects of the external field on viscosity measurements are experimentally confirmed by changing the sample size. Moreover, a numerical simulation based on a simple mass-spring-damper system can reproduce the experimental observations. Based on the above results, measurement procedures are improved. These help to minimize the effect of the positioning force and to increase the accuracy of the viscosity measurements.

  2. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  3. Measuring use of positive thinking skills: psychometric testing of a new scale.

    Science.gov (United States)

    Bekhet, Abir K; Zauszniewski, Jaclene A

    2013-09-01

    Positive thinking interventions improve adaptive functioning and quality of life in many populations. However, no direct measure of positive thinking skills taught during intervention exists. This psychometric study of a convenience sample of 109 autism spectrum disorder (ASD) caregivers examined a new eight-item Positive Thinking Skills Scale (PTSS), which measures the frequency of use of positive thinking skills. The PTSS was found to be internally consistent (α = .90). Construct validity was supported by significant correlations (p thinking skills could provide direction for future intervention.

  4. Technique for the focal-length measurement of positive lenses using Fizeau interferometry

    International Nuclear Information System (INIS)

    Pavan Kumar, Yeddanapudi; Chatterjee, Sanjib

    2009-01-01

    We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of ±2.5% is presented

  5. Investigating and improving student understanding of the probability distributions for measuring physical observables in quantum mechanics

    International Nuclear Information System (INIS)

    Marshman, Emily; Singh, Chandralekha

    2017-01-01

    A solid grasp of the probability distributions for measuring physical observables is central to connecting the quantum formalism to measurements. However, students often struggle with the probability distributions of measurement outcomes for an observable and have difficulty expressing this concept in different representations. Here we first describe the difficulties that upper-level undergraduate and PhD students have with the probability distributions for measuring physical observables in quantum mechanics. We then discuss how student difficulties found in written surveys and individual interviews were used as a guide in the development of a quantum interactive learning tutorial (QuILT) to help students develop a good grasp of the probability distributions of measurement outcomes for physical observables. The QuILT strives to help students become proficient in expressing the probability distributions for the measurement of physical observables in Dirac notation and in the position representation and be able to convert from Dirac notation to position representation and vice versa. We describe the development and evaluation of the QuILT and findings about the effectiveness of the QuILT from in-class evaluations. (paper)

  6. Global regulation of robots using only position measurements

    NARCIS (Netherlands)

    Berghuis, Harry; Berghuis, Harry; Nijmeijer, Henk

    1993-01-01

    In this note we propose a simple solution to the regulation problem of rigid robots based on the availability of only joint position measurements. The controller consists of two parts: (1) a gravitation compensation, (2) a linear dynamic first-order compensator. The gravitation compensation part can

  7. Theory of “Weak Value" and Quantum Mechanical Measurements

    OpenAIRE

    Shikano, Yutaka

    2012-01-01

    Comment: to be published from "Measurements in Quantum Mechanics", edited by M. R. Pahlavani (InTech, 2012) Chapter 4 page 75. Yutaka Shikano (2012). ISBN: 978-953-51-0058-4 Available from: http://www.intechopen.com/articles/show/title/theory-of-weak-value-and-quantum-mechanical-measurement

  8. Mobility and Position Error Analysis of a Complex Planar Mechanism with Redundant Constraints

    Science.gov (United States)

    Sun, Qipeng; Li, Gangyan

    2018-03-01

    Nowadays mechanisms with redundant constraints have been created and attracted much attention for their merits. The mechanism of the redundant constraints in a mechanical system is analyzed in this paper. A analysis method of Planar Linkage with a repetitive structure is proposed to get the number and type of constraints. According to the difference of applications and constraint characteristics, the redundant constraints are divided into the theoretical planar redundant constraints and the space-planar redundant constraints. And the calculation formula for the number of redundant constraints and type of judging method are carried out. And a complex mechanism with redundant constraints is analyzed of the influence about redundant constraints on mechanical performance. With the combination of theoretical derivation and simulation research, a mechanism analysis method is put forward about the position error of complex mechanism with redundant constraints. It points out the direction on how to eliminate or reduce the influence of redundant constraints.

  9. Accelerator and Technical Sector Seminar: Mechanical stabilization and positioning of CLIC quadrupoles with sub-nanometre resolution

    CERN Multimedia

    2011-01-01

    Thursday 24 November 2010 Accelerator and Technical Sector Seminar at 14:15  -  BE Auditorium, bldg. 6 (Meyrin) – please note unusual place Mechanical stabilization and positioning of CLIC quadrupoles with sub-nanometre resolution Stef Janssens /EN-MME Abstract: To reach the required luminosity at the CLIC interaction point, about 4000 quadrupoles are needed to obtain a vertical beam size of 1 nm at the interaction point. The mechanical jitter of the quadrupole magnets will result in an emittance growth. An active vibration isolation system is required to reduce vibrations from the ground and from external forces to about 1.5 nm integrated root mean square (r.m.s.) vertical displacement at 1 Hz. A short overview of vibration damping and isolation strategies will be presented as well as a comparison of existing systems. The unprecedented resolution requirements and the instruments enabling these measurements will be discussed. The vibration sources from which the magnets need to...

  10. Measurement of material mechanical properties in microforming

    Science.gov (United States)

    Yun, Wang; Xu, Zhenying; Hui, Huang; Zhou, Jianzhong

    2006-02-01

    As the rapid market need of micro-electro-mechanical systems engineering gives it the wide development and application ranging from mobile phones to medical apparatus, the need of metal micro-parts is increasing gradually. Microforming technology challenges the plastic processing technology. The findings have shown that if the grain size of the specimen remains constant, the flow stress changes with the increasing miniaturization, and also the necking elongation and the uniform elongation etc. It is impossible to get the specimen material properties in conventional tensile test machine, especially in the high precision demand. Therefore, one new measurement method for getting the specimen material-mechanical property with high precision is initiated. With this method, coupled with the high speed of Charge Coupled Device (CCD) camera and high precision of Coordinate Measuring Machine (CMM), the elongation and tensile strain in the gauge length are obtained. The elongation, yield stress and other mechanical properties can be calculated from the relationship between the images and CCD camera movement. This measuring method can be extended into other experiments, such as the alignment of the tool and specimen, micro-drawing process.

  11. Entanglement and the process of measuring the position of a quantum particle

    International Nuclear Information System (INIS)

    Apel, V.M.; Curilef, S.; Plastino, A.R.

    2015-01-01

    We explore the entanglement-related features exhibited by the dynamics of a composite quantum system consisting of a particle and an apparatus (here referred to as the “pointer”) that measures the position of the particle. We consider measurements of finite duration, and also the limit case of instantaneous measurements. We investigate the time evolution of the quantum entanglement between the particle and the pointer, with special emphasis on the final entanglement associated with the limit case of an impulsive interaction. We consider entanglement indicators based on the expectation values of an appropriate family of observables, and also an entanglement measure computed on particular exact analytical solutions of the particle–pointer Schrödinger equation. The general behavior exhibited by the entanglement indicators is consistent with that shown by the entanglement measure evaluated on particular analytical solutions of the Schrödinger equation. In the limit of instantaneous measurements the system’s entanglement dynamics corresponds to that of an ideal quantum measurement process. On the contrary, we show that the entanglement evolution corresponding to measurements of finite duration departs in important ways from the behavior associated with ideal measurements. In particular, highly localized initial states of the particle lead to highly entangled final states of the particle–pointer system. This indicates that the above mentioned initial states, in spite of having an arbitrarily small position uncertainty, are not left unchanged by a finite-duration position measurement process. - Highlights: • We explore entanglement features of a quantum position measurement. • We consider instantaneous and finite-duration measurements. • We evaluate the entanglement of exact time-dependent particle–pointer states

  12. Universal happiness? Cross-cultural measurement invariance of scales assessing positive mental health.

    Science.gov (United States)

    Bieda, Angela; Hirschfeld, Gerrit; Schönfeld, Pia; Brailovskaia, Julia; Zhang, Xiao Chi; Margraf, Jürgen

    2017-04-01

    Research into positive aspects of the psyche is growing as psychologists learn more about the protective role of positive processes in the development and course of mental disorders, and about their substantial role in promoting mental health. With increasing globalization, there is strong interest in studies examining positive constructs across cultures. To obtain valid cross-cultural comparisons, measurement invariance for the scales assessing positive constructs has to be established. The current study aims to assess the cross-cultural measurement invariance of questionnaires for 6 positive constructs: Social Support (Fydrich, Sommer, Tydecks, & Brähler, 2009), Happiness (Subjective Happiness Scale; Lyubomirsky & Lepper, 1999), Life Satisfaction (Diener, Emmons, Larsen, & Griffin, 1985), Positive Mental Health Scale (Lukat, Margraf, Lutz, van der Veld, & Becker, 2016), Optimism (revised Life Orientation Test [LOT-R]; Scheier, Carver, & Bridges, 1994) and Resilience (Schumacher, Leppert, Gunzelmann, Strauss, & Brähler, 2004). Participants included German (n = 4,453), Russian (n = 3,806), and Chinese (n = 12,524) university students. Confirmatory factor analyses and measurement invariance testing demonstrated at least partial strong measurement invariance for all scales except the LOT-R and Subjective Happiness Scale. The latent mean comparisons of the constructs indicated differences between national groups. Potential methodological and cultural explanations for the intergroup differences are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Classical Mechanics as Nonlinear Quantum Mechanics

    International Nuclear Information System (INIS)

    Nikolic, Hrvoje

    2007-01-01

    All measurable predictions of classical mechanics can be reproduced from a quantum-like interpretation of a nonlinear Schroedinger equation. The key observation leading to classical physics is the fact that a wave function that satisfies a linear equation is real and positive, rather than complex. This has profound implications on the role of the Bohmian classical-like interpretation of linear quantum mechanics, as well as on the possibilities to find a consistent interpretation of arbitrary nonlinear generalizations of quantum mechanics

  14. Measurement of the mechanical properties of layered systems

    International Nuclear Information System (INIS)

    Blank, E.

    2002-01-01

    Thin films for integrated electronic circuitry, packaging and small structures in micro-electromechanical systems (MEMS) as well as protective coatings require mechanical testing to control fabrication processes, guarantee product quality and establish data bases for engineering purposes. They generally escape classical materials testing owing to their small size in at least one dimension and their incorporation into larger structures. The fact that material properties change in the micro- and nanometer range when sample dimensions reach the scale of defect structures, implies that sample and probe size become part of the property evaluation process. Although research into the mechanical behaviour of thin films and small structures now is established, the fundamentals of mechanical testing continue to be identified while there is a growing need for methods allowing to measure intrinsic material properties. This lecture will focus on the mechanics of thin film and small volume structures and review recently developed testing techniques for measuring materials properties, particularly indentation, bulge and bend testing. The effect of specimen and probe geometry on property evaluation will be discussed. The use of Raman spectroscopy for residual stress measurement will be illustrated. (Author)

  15. The measurement of the radioactive aerosol diameter by position sensitive detectors, 3

    International Nuclear Information System (INIS)

    Murakami, Hiroyuki; Nakamoto, Atsushi; Kanamori, Masashi; Seki, Akio.

    1981-10-01

    The measurement of the diameter of radioactive aerosol, in particular plutonium aerosol, is very important for the internal dose estimation. Determination of the diameter of radioactive aerosol is performed by using the position sensitive detectors. Position sensitive semiconductor detectors and Scintillation detectors with IIT tube are used as the position sensitive detector. The filter paper with the radioactive aerosols is contacted to the PSD which is connected to the data processor so that the diameter of the aerosol is calculated from the measured radioactivity. (author)

  16. Information Geometry of Positive Measures and Positive-Definite Matrices: Decomposable Dually Flat Structure

    Directory of Open Access Journals (Sweden)

    Shun-ichi Amari

    2014-04-01

    Full Text Available Information geometry studies the dually flat structure of a manifold, highlighted by the generalized Pythagorean theorem. The present paper studies a class of Bregman divergences called the (ρ,τ-divergence. A (ρ,τ -divergence generates a dually flat structure in the manifold of positive measures, as well as in the manifold of positive-definite matrices. The class is composed of decomposable divergences, which are written as a sum of componentwise divergences. Conversely, a decomposable dually flat divergence is shown to be a (ρ,τ -divergence. A (ρ,τ -divergence is determined from two monotone scalar functions, ρ and τ. The class includes the KL-divergence, α-, β- and (α, β-divergences as special cases. The transformation between an affine parameter and its dual is easily calculated in the case of a decomposable divergence. Therefore, such a divergence is useful for obtaining the center for a cluster of points, which will be applied to classification and information retrieval in vision. For the manifold of positive-definite matrices, in addition to the dually flatness and decomposability, we require the invariance under linear transformations, in particular under orthogonal transformations. This opens a way to define a new class of divergences, called the (ρ,τ -structure in the manifold of positive-definite matrices.

  17. Measurements of plasma position in TJ-I Tokamak

    International Nuclear Information System (INIS)

    Qin, J.; Ascasibar, E.; Navarro, A.P.; Ochando, M.A.; Pastor, I.; Pedrosa, M.A.; Rodriguez, L.; Sanchez, J.; Team, TJ-I.

    1994-01-01

    This report presents the experimental measurements of plasma position in TJ-I tokamak by using small magnetic probes. The basis of method has been described in our previous work (1) in which the plasma current is considered as a filament current. The observed relations between the disruptive instabilities and plasma displacements are also show here. (Author) 7 refs

  18. A robust rotation-invariance displacement measurement method for a micro-/nano-positioning system

    Science.gov (United States)

    Zhang, Xiang; Zhang, Xianmin; Wu, Heng; Li, Hai; Gan, Jinqiang

    2018-05-01

    A robust and high-precision displacement measurement method for a compliant mechanism-based micro-/nano-positioning system is proposed. The method is composed of an integer-pixel and a sub-pixel matching procedure. In the proposed algorithm (Pro-A), an improved ring projection transform (IRPT) and gradient information are used as features for approximating the coarse candidates and fine locations, respectively. Simulations are conducted and the results show that the Pro-A has the ability of rotation-invariance and strong robustness, with a theoretical accuracy of 0.01 pixel. To validate the practical performance, a series of experiments are carried out using a computer micro-vision and laser interferometer system (LIMS). The results demonstrate that both the LIMS and Pro-A can achieve high precision, while the Pro-A has better stability and adaptability.

  19. Measurement of Mechanical Properties of Cantilever Shaped Materials

    Directory of Open Access Journals (Sweden)

    Thomas Thundat

    2008-05-01

    Full Text Available Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM due to their extremely high sensitivity in measuring surface forces. The versatility of these probes, however, allows the sensing and measurement of a host of mechanical properties of various materials. Sensor parameters such as resonance frequency, quality factor, amplitude of vibration and bending due to a differential stress can all be simultaneously determined for a cantilever. When measuring the mechanical properties of materials, identifying and discerning the most influential parameters responsible for the observed changes in the cantilever response are important. We will, therefore, discuss the effects of various force fields such as those induced by mass loading, residual stress, internal friction of the material, and other changes in the mechanical properties of the microcantilevers. Methods to measure variations in temperature, pressure, or molecular adsorption of water molecules are also discussed. Often these effects occur simultaneously, increasing the number of parameters that need to be concurrently measured to ensure the reliability of the sensors. We therefore systematically investigate the geometric and environmental effects on cantilever measurements including the chemical nature of the underlying interactions. To address the geometric effects we have considered cantilevers with a rectangular or circular cross section. The chemical nature is addressed by using cantilevers fabricated with metals and/or dielectrics. Selective chemical etching, swelling or changes in Young’s modulus of the surface were investigated by means of polymeric and inorganic coatings. Finally to address the effect of the environment in which the cantilever operates, the Knudsen number was determined to characterize the molecule-cantilever collisions. Also bimaterial cantilevers with high thermal sensitivity were used to discern the effect of temperature

  20. Meanings, mechanisms, and measures of holistic processing.

    Science.gov (United States)

    Richler, Jennifer J; Palmeri, Thomas J; Gauthier, Isabel

    2012-01-01

    Few concepts are more central to the study of face recognition than holistic processing. Progress toward understanding holistic processing is challenging because the term "holistic" has many meanings, with different researchers addressing different mechanisms and favoring different measures. While in principle the use of different measures should provide converging evidence for a common theoretical construct, convergence has been slow to emerge. We explore why this is the case. One challenge is that "holistic processing" is often used to describe both a theoretical construct and a measured effect, which may not have a one-to-one mapping. Progress requires more than greater precision in terminology regarding different measures of holistic processing or different hypothesized mechanisms of holistic processing. Researchers also need to be explicit about what meaning of holistic processing they are investigating so that it is clear whether different researchers are describing the same phenomenon or not. Face recognition differs from object recognition, and not all meanings of holistic processing are equally suited to help us understand that important difference.

  1. Description and operation of the LEDA beam-position/intensity measurement module

    International Nuclear Information System (INIS)

    Rose, C.R.; Stettler, M.W.

    1997-01-01

    This paper describes the specification, design and preliminary operation of the beam-position/intensity measurement module being built for the Low Energy Demonstration Accelerator (LEDA) and Accelerator Production of Tritium (APT) projects at Los Alamos National Laboratory. The module, based on the VXI footprint, is divided into three sections: first, the analog front-end which consists of logarithmic amplifiers, anti-alias filters, and digitizers; second, the digital-to-analog section for monitoring signals on the front panel; and third, the DSP, error correction, and VXI-interface section. Beam position is calculated based on the log-ratio transfer function. The module has four, 2-MHz, IF inputs suitable for two-axis position measurements. It has outputs in both digital and analog format for x- and y-position and beam intensity. Real-time error-correction is performed on the four input signals after they are digitized and before calculating the beam position to compensate for drift, offsets, gain non-linearities, and other systematic errors. This paper also describes how the on-line error-correction is implemented digitally and algorithmically

  2. Intraoperative mechanical measurement of bone quality with the DensiProbe.

    Science.gov (United States)

    Hoppe, Sven; Uhlmann, Michael; Schwyn, Robert; Suhm, Norbert; Benneker, Lorin M

    2015-01-01

    Reduced bone stock can result in fractures that mostly occur in the spine, distal radius, and proximal femur. In case of operative treatment, osteoporosis is associated with an increased failure rate. To estimate implant anchorage, mechanical methods seem to be promising to measure bone strength intraoperatively. It has been shown that the mechanical peak torque correlates with the local bone mineral density and screw failure load in hip, hindfoot, humerus, and spine in vitro. One device to measure mechanical peak torque is the DensiProbe (AO Research Institute, Davos, Switzerland). The device has shown its effectiveness in mechanical peak torque measurement in mechanical testing setups for the use in hip, hindfoot, and spine. In all studies, the correlation of mechanical torque measurement and local bone mineral density and screw failure load could be shown. It allows the surgeon to judge local bone strength intraoperatively directly at the region of interest and gives valuable information if additional augmentation is needed. We summarize methods of this new technique, its advantages and limitations, and give an overview of actual and possible future applications. Copyright © 2015 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  3. Positive psychology outcome measures for family caregivers of people living with dementia: a systematic review.

    Science.gov (United States)

    Stansfeld, Jacki; Stoner, Charlotte R; Wenborn, Jennifer; Vernooij-Dassen, Myrra; Moniz-Cook, Esme; Orrell, Martin

    2017-08-01

    Family caregivers of people living with dementia can have both positive and negative experiences of caregiving. Despite this, existing outcome measures predominately focus on negative aspects of caregiving such as burden and depression. This review aimed to evaluate the development and psychometric properties of existing positive psychology measures for family caregivers of people living with dementia to determine their potential utility in research and practice. A systematic review of positive psychology outcome measures for family caregivers of people with dementia was conducted. The databases searched were as follows: PsychINFO, CINAHL, MEDLINE, EMBASE, and PubMed. Scale development papers were subject to a quality assessment to appraise psychometric properties. Twelve positive outcome measures and six validation papers of these scales were identified. The emerging constructs of self-efficacy, spirituality, resilience, rewards, gain, and meaning are in line with positive psychology theory. There are some robust positive measures in existence for family caregivers of people living with dementia. However, lack of reporting of the psychometric properties hindered the quality assessment of some outcome measures identified in this review. Future research should aim to include positive outcome measures in interventional research to facilitate a greater understanding of the positive aspects of caregiving and how these contribute to well-being.

  4. Related factors to semi-recumbent position compliance and pressure ulcers in patients with invasive mechanical ventilation: An observational study (CAPCRI study).

    Science.gov (United States)

    Llaurado-Serra, Mireia; Ulldemolins, Marta; Fernandez-Ballart, Joan; Guell-Baro, Rosa; Valentí-Trulls, Teresa; Calpe-Damians, Neus; Piñol-Tena, Angels; Pi-Guerrero, Mercedes; Paños-Espinosa, Cristina; Sandiumenge, Alberto; Jimenez-Herrera, María F

    2016-09-01

    Semi-recumbent position is recommended to prevent ventilator-associated pneumonia. Its implementation, however, is below optimal. We aimed to assess real semi-recumbent position compliance and the degree of head-of-bed elevation in Spanish intensive care units, along with factors determining compliance and head-of-bed elevation and their relationship with the development of pressure ulcers. Finally, we investigated the impact that might have the diagnosis of pressure ulcers in the attitude toward head-of-bed elevation. We performed a prospective, multicenter, observational study in 6 intensive care units. Inclusion criteria were patients ≥18 years old and expected to remain under mechanical ventilator for ≥48h. Exclusion criteria were patients with contraindications for semi-recumbent position from admission, mechanical ventilation during the previous 7 days and prehospital intubation. Head-of-bed elevation was measured 3 times/day for a maximum of 28 days using the BOSCH GLM80(®) device. The variables collected related to patient admission, risk of pressure ulcers and the measurements themselves. Bivariate and multivariate analyses were carried out using multiple binary logistic regression and linear regression as appropriate. Statistical significance was set at preplacement therapy, nursing shift, open abdomen, abdominal vacuum therapy and agitation. Twenty-five patients (9.1%) developed a total of 34 pressure ulcers. The diagnosis of pressure ulcers did not affect the head-of-bed elevation. In the multivariate analysis, head-of-bed elevation was not identified as an independent risk factor for pressure ulcers. Semi-recumbent position compliance is below optimal despite the fact that it seems achievable most of the time. Factors that affect semi-recumbent position include the particular intensive care unit, abdominal conditions, renal replacement therapy, agitation and bed type. Head-of-bed elevation was not related to the risk of pressure ulcers. Efforts

  5. Semi-recumbent position versus supine position for the prevention of ventilator-associated pneumonia in adults requiring mechanical ventilation.

    Science.gov (United States)

    Wang, Li; Li, Xiao; Yang, Zongxia; Tang, Xueli; Yuan, Qiang; Deng, Lijing; Sun, Xin

    2016-01-08

    Ventilator-associated pneumonia (VAP) is associated with increased mortality, prolonged length of hospital stay and increased healthcare costs in critically ill patients. Guidelines recommend a semi-recumbent position (30º to 45º) for preventing VAP among patients requiring mechanical ventilation. However, due to methodological limitations in existing systematic reviews, uncertainty remains regarding the benefits and harms of the semi-recumbent position for preventing VAP. To assess the effectiveness and safety of semi-recumbent positioning versus supine positioning to prevent ventilator-associated pneumonia (VAP) in adults requiring mechanical ventilation. We searched CENTRAL (2015, Issue 10), which includes the Cochrane Acute Respiratory Infections Group's Specialised Register, MEDLINE (1946 to October 2015), EMBASE (2010 to October 2015), CINAHL (1981 to October 2015) and the Chinese Biomedical Literature Database (CBM) (1978 to October 2015). We included randomised controlled trials (RCTs) comparing semi-recumbent versus supine positioning (0º to 10º), or RCTs comparing alternative degrees of positioning in mechanically ventilated patients. Our outcomes included clinically suspected VAP, microbiologically confirmed VAP, intensive care unit (ICU) mortality, hospital mortality, length of ICU stay, length of hospital stay, duration of ventilation, antibiotic use and any adverse events. Two review authors independently and in duplicate screened titles, abstracts and full texts, assessed risk of bias and extracted data using standardised forms. We calculated the mean difference (MD) and 95% confidence interval (95% CI) for continuous data and the risk ratio (RR) and 95% CI for binary data. We performed meta-analysis using the random-effects model. We used the grading of recommendations, assessment, development and evaluation (GRADE) approach to grade the quality of evidence. We included 10 trials involving 878 participants, among which 28 participants in two

  6. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  7. Resolution and drift measurements on the Advanced Photon Source beam position monitors

    International Nuclear Information System (INIS)

    Chung, Y.; Kahana, E.

    1994-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N = 2 n , n = 1, 2, ... , 11). Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√ N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed

  8. Phonon number measurements using single photon opto-mechanics

    International Nuclear Information System (INIS)

    Basiri-Esfahani, S; Akram, U; Milburn, G J

    2012-01-01

    We describe a system composed of two coupled optical cavity modes with a coupling modulated by a bulk mechanical resonator. In addition, one of the cavity modes is irreversibly coupled to a single photon source. Our scheme is an opto-mechanical realization of the Jaynes–Cummings model where the qubit is a dual rail optical qubit while the bosonic degree of freedom is a matter degree of freedom realized as the bulk mechanical excitation. We show the possibility of engineering phonon number states of the mechanical oscillator in such a system by computing the conditional state of the mechanics after successive photon counting measurements. (paper)

  9. Measurements of Positively Charged Ions in Premixed Methane-Oxygen Atmospheric Flames

    KAUST Repository

    Alquaity, Awad

    2016-08-22

    Cations and anions are formed as a result of chemi-ionization processes in combustion systems. Electric fields can be applied to reduce emissions and improve combustion efficiency by active control of the combustion process. Detailed flame ion chemistry models are needed to understand and predict the effect of external electric fields on combustion plasmas. In this work, a molecular beam mass spectrometer (MBMS) is utilized to measure ion concentration profiles in premixed methane–oxygen argon burner-stabilized atmospheric flames. Lean and stoichiometric flames are considered to assess the dependence of ion chemistry on flame stoichiometry. Relative ion concentration profiles are compared with numerical simulations using various temperature profiles, and good qualitative agreement was observed for the stoichiometric flame. However, for the lean flame, numerical simulations misrepresent the spatial distribution of selected ions greatly. Three modifications are suggested to enhance the ion mechanism and improve the agreement between experiments and simulations. The first two modifications comprise the addition of anion detachment reactions to increase anion recombination at low temperatures. The third modification involves restoring a detachment reaction to its original irreversible form. To our knowledge, this work presents the first detailed measurements of cations and flame temperature in canonical methane–oxygen-argon atmospheric flat flames. The positive ion profiles reported here may be useful to validate and improve ion chemistry models for methane-oxygen flames.

  10. Two-Dimensional Electron Density Measurement of Positive Streamer Discharge in Atmospheric-Pressure Air

    Science.gov (United States)

    Inada, Yuki; Ono, Ryo; Kumada, Akiko; Hidaka, Kunihiko; Maeyama, Mitsuaki

    2016-09-01

    The electron density of streamer discharges propagating in atmospheric-pressure air is crucially important for systematic understanding of the production mechanisms of reactive species utilized in wide ranging applications such as medical treatment, plasma-assisted ignition and combustion, ozone production and environmental pollutant processing. However, electron density measurement during the propagation of the atmospheric-pressure streamers is extremely difficult by using the conventional localized type measurement systems due to the streamer initiation jitters and the irreproducibility in the discharge paths. In order to overcome the difficulties, single-shot two-dimensional electron density measurement was conducted by using a Shack-Hartmann type laser wavefront sensor. The Shack-Hartmann sensor with a temporal resolution of 2 ns was applied to pulsed positive streamer discharges generated in an air gap between pin-to-plate electrodes. The electron density a few ns after the streamer initiation was 7*1021m-3 and uniformly distributed along the streamer channel. The electron density and its distribution profile were compared with a previous study simulating similar streamers, demonstrating good agreement. This work was supported in part by JKA and its promotion funds from KEIRIN RACE. The authors like to thank Mr. Kazuaki Ogura and Mr. Kaiho Aono of The University of Tokyo for their support during this work.

  11. Analysis of ping-pong reaction mechanisms by positional isotope exchange. Application to galactose-1-phosphate uridyltransferase

    International Nuclear Information System (INIS)

    Hester, L.S.; Raushel, F.M.

    1987-01-01

    A new positional isotope exchange method has been developed that can be used for the analysis of enzyme-catalyzed reactions which have ping-pong kinetic mechanisms. The technique can be used to measure the relative rates of ligand dissociation from enzyme-product complexes. Enzyme is incubated with the labeled substrate and an excess of the corresponding unlabeled product. The partitioning of the enzyme-product complex back toward free enzyme is determined from the rate of positional isotope exchange within the original labeled substrate. The partitioning of the enzyme-product complex forward toward free enzyme is determined from the rate of formation of totally unlabeled substrate. It has been shown that the ratio of the two rates provides a lower limit for the release of product from the enzyme-product complex. The technique has been applied to the reaction catalyzed by galactose-1-phosphate uridyltransferase. The lower limit for the release of glucose 1-phosphate from the uridyl-enzyme relative to the maximal velocity of the reverse reaction was determined to be 3.4 +/- 0.5

  12. Uav Positioning and Collision Avoidance Based on RSS Measurements

    Science.gov (United States)

    Masiero, A.; Fissore, F.; Guarnieri, A.; Pirotti, F.; Vettore, A.

    2015-08-01

    In recent years, Unmanned Aerial Vehicles (UAVs) are attracting more and more attention in both the research and industrial communities: indeed, the possibility to use them in a wide range of remote sensing applications makes them a very flexible and attractive solution in both civil and commercial cases (e.g. precision agriculture, security and control, monitoring of sites, exploration of areas difficult to reach). Most of the existing UAV positioning systems rely on the use of the GPS signal. Despite this can be a satisfactory solution in open environments where the GPS signal is available, there are several operating conditions of interest where it is unavailable or unreliable (e.g. close to high buildings, or mountains, in indoor environments). Consequently, a different approach has to be adopted in these cases. This paper considers the use ofWiFi measurements in order to obtain position estimations of the device of interest. More specifically, to limit the costs for the devices involved in the positioning operations, an approach based on radio signal strengths (RSS) measurements is considered. Thanks to the use of a Kalman filter, the proposed approach takes advantage of the temporal dynamic of the device of interest in order to improve the positioning results initially provided by means of maximum likelihood estimations. The considered UAVs are assumed to be provided with communication devices, which can allow them to communicate with each other in order to improve their cooperation abilities. In particular, the collision avoidance problem is examined in this work.

  13. Broadband Laser Ranging for Position Measurements in Shock Physics Experiments

    Science.gov (United States)

    Rhodes, Michelle; Bennett, Corey; Daykin, Edward; Younk, Patrick; Lalone, Brandon; Kostinski, Natalie

    2017-06-01

    Broadband laser ranging (BLR) is a recently developed measurement system that provides an attractive option for determining the position of shock-driven surfaces. This system uses broadband, picosecond (or femtosecond) laser pulses and a fiber interferometer to measure relative travel time to a target and to a reference mirror. The difference in travel time produces a delay difference between pulse replicas that creates a spectral beat frequency. The spectral beating is recorded in real time using a dispersive Fourier transform and an oscilloscope. BLR systems have been designed that measure position at 12.5-40 MHz with better than 100 micron accuracy over ranges greater than 10 cm. We will give an overview of the basic operating principles of these systems. Prepared by LLNL under Contract DE-AC52-07NA27344, by LANL under Contract DE-AC52-06NA25396, and by NSTec Contract DE-AC52-06NA25946.

  14. Development of a Computerized Multifunctional Form and Position Measurement Instrument

    International Nuclear Information System (INIS)

    Liu, P; Tian, W Y

    2006-01-01

    A model machine of multifunctional form and position measurement instrument controlled by a personal computer has been successfully developed. The instrument is designed in rotary table type with a high precision air bearing and the radial rotation error of the rotary table is 0.08 μm. Since a high precision vertical sliding carriage supported by an air bearing is used for the instrument, the straightaway motion error of the carriage is 0.3 μm/200 mm and the parallelism error of the motion of the carriage relative to the rotation axis of the rotary table is 0.4 μm/200 mm. The mathematical models have been established for assessing planar and spatial straightness, flatness, roundness, cylindricity, and coaxality errors. By radial deviation measurement, the instrument can accurately measure form and position errors of such workpieces as shafts, round plates and sleeves of medium or small dimensions with the tolerance grades mostly used in industry

  15. Factor Structure and Initial Validation of a Multidimensional Measure of Difficulties in the Regulation of Positive Emotions: The DERS-Positive.

    Science.gov (United States)

    Weiss, Nicole H; Gratz, Kim L; Lavender, Jason M

    2015-05-01

    Emotion regulation difficulties are a transdiagnostic construct relevant to numerous clinical difficulties. Although the Difficulties in Emotion Regulation Scale (DERS) is a multidimensional measure of maladaptive ways of responding to emotions, it focuses on difficulties with the regulation of negative emotions and does not assess emotion dysregulation in the form of problematic responding to positive emotions. The aim of this study was to develop and validate a measure of clinically relevant difficulties in the regulation of positive emotions (DERS-Positive). Findings revealed a three-factor structure and supported the internal consistency and construct validity of the total and subscale scores. © The Author(s) 2015.

  16. Does the Supine Position Affect the Nasal Profile in Rhinoplasty Patients? A Comparison of Nasal Anthropometric Measurements in Different Body Positions.

    Science.gov (United States)

    Kim, Su Jin; Ryu, In Yong; Kim, Sung Wan; Lee, Kun Hee

    2017-10-16

    Rhinoplasty surgeons are aware that the nasal profile differs according to body position, namely, the erect position in the consultation room vs the supine position on the operating table. It is not clear whether this difference is caused by an optical illusion or skin laxity due to positional change. To evaluate anthropometric measurements of the nose with different body positions and determine whether the supine position affects the nasal profile. In this retrospective study, 103 patients who underwent primary rhinoplasty were enrolled. Preoperatively, all patients underwent lateral cephalography in the erect position, and facial computed tomography (CT), in the supine position. We measured four nasal anthropometric parameters (the nasofrontal, nasolabial, and nasomental angles, and Simon's ratio) on lateral cephalograms and facial CT images, and compared these parameters between the two body positions. The nasofrontal angle was greater on facial CT than on cephalograms (P sex, or body mass index (P > 0.05 each). We found no significant difference (P > 0.05) between the two positions in the nasolabial angle, nasomental angle, or Simon's ratio. The supine position does affect the nasal profile, especially in the radix area. Surgeons need to consider this difference in patients undergoing rhinoplasty. 2. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  17. Resolution and drift measurements on the advanced photon source beam position monitor

    International Nuclear Information System (INIS)

    Chung, Y.; Kahana, E.

    1995-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N=2 n , n=1,2,...,11) . Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed. copyright 1995 American Institute of Physics

  18. Positional Differences in Elite Basketball: Selecting Appropriate Training - Load Measures.

    Science.gov (United States)

    Svilar, Luka; Castellano, Julen; Jukic, Igor; Casamichana, David

    2018-01-18

    The purpose of this paper was to study the structure of interrelationships among external training load measures and how these vary among different positions in elite basketball. Eight external variables of jumping (JUMP), acceleration (ACC), deceleration (DEC) and change of direction (COD), and two internal load variables (RPE and sRPE) were collected from 13 professional players with 300 session records. Three playing positions were considered: guards (n=4), forwards (n=4) and centers (n=5). High and total external variables (hJUMP and tJUMP, hACC and tACC, hDEC and tDEC, hCOD and tCOD) were used for the principal component analysis. Extraction criteria were set at the eigenvalue of greater than one. Varimax rotation mode was used to extract multiple principal components. The analysis showed that all positions had two or three principal components (explaining almost all of the variance), but the configuration of each factor was different: tACC, tDEC, tCOD and hJUMP for centers, hACC, tACC, tCOD and hJUMP for guards, and tACC, hDEC, tDEC, hCOD, and tCOD for forwards are specifically demanded in training sessions and, therefore, these variables must be prioritized in load monitoring. Furthermore, for all playing positions, RPE and sRPE have high correlation with the total amount of ACC, DEC and COD. This would suggest that, although players perform the same training tasks, the demands of each position can vary. A particular combination of external load measures is required to describe training load of each playing position, especially to better understand internal responses among players.

  19. New positive feedback mechanism between boundary layer meteorology and secondary aerosol formation during severe haze events.

    Science.gov (United States)

    Liu, Quan; Jia, Xingcan; Quan, Jiannong; Li, Jiayun; Li, Xia; Wu, Yongxue; Chen, Dan; Wang, Zifa; Liu, Yangang

    2018-04-17

    Severe haze events during which particulate matter (PM) increases quickly from tens to hundreds of microgram per cubic meter in 1-2 days frequently occur in China. Although it has been known that PM is influenced by complex interplays among emissions, meteorology, and physical and chemical processes, specific mechanisms remain elusive. Here, a new positive feedback mechanism between planetary boundary layer (PBL), relative humidity (RH), and secondary PM (SPM) formation is proposed based on a comprehensive field experiment and model simulation. The decreased PBL associated with increased PM increases RH by weakening the vertical transport of water vapor; the increased RH in turn enhances the SPM formation through heterogeneous aqueous reactions, which further enhances PM, weakens solar radiation, and decreases PBL height. This positive feedback, together with the PM-Radiation-PBL feedback, constitutes a key mechanism that links PM, radiation, PBL properties (e.g. PBL height and RH), and SPM formation, This mechanism is self-amplifying, leading to faster PM production, accumulation, and more severe haze pollution.

  20. Automated bead-positioning system for measuring impedances of R-F cavity modes

    International Nuclear Information System (INIS)

    Goldberg, D.A.; Rimmer, R.A.

    1993-05-01

    We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper

  1. Position sensitive proportional counter for measurement of tritium labelled gas movement

    International Nuclear Information System (INIS)

    Mori, Chizuo; Nakamoto, Makihiko; Uritani, Akira; Watanabe, Tamaki

    1984-01-01

    A position sensitive proportional counter of a charge division type with a single resistive anode wire was constructed for the measurement of the movement of 3 H labelled gas which is flowing or diffusing in a pipe. The introduction of resistors between the anode wire and pre-amplifiers brought a uniform detection efficiency for 3 H β-rays throughout the counter. The position resolution was 3.1 mm FWHM. Detection efficiency was almost 100% uniformly over about 700 mm in the total anode length of 740 mm. The movement of 3 H labelled gas could be measured effectively. (author)

  2. Measurement of spatial dose-rate distribution using a position sensitive detector

    International Nuclear Information System (INIS)

    Emoto, T.; Torii, T.; Nozaki, T.; Ando, H.

    1994-01-01

    Recently, the radiation detectors using plastic scintillation fibers (PSF) have been developed to measure the positions exposed to radiation such as neutrons and high energy charged particles. In particular, the time of flight (TOF) method for measuring the difference of time that two directional signals of scintillation light reach both ends of a PSF is a rather simple method for the measurement of the spatial distribution of fast neutron fluence rate. It is possible to use the PSF in nuclear facility working areas because of its flexibility, small diameter and long length. In order to apply TOF method to measure spatial gamma dose rate distribution, the characteristic tests of a detector using PSFs were carried out. First, the resolution of irradiated positions and the counting efficiency were measured with collimated gamma ray. The sensitivity to unit dose rate was also obtained. The measurement of spatial dose rate distribution was also carried out. The sensor is made of ten bundled PSFs, and the experimental setup is described. The experiment and the results are reported. It was found that the PSF detector has the good performance to measure spatial gamma dose rate distribution. (K.I.)

  3. Automatic positioning control device for automatic control rod exchanger

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To attain accurate positioning for a control rod exchanger. Constitution: The present position for an automatic control rod exchanger is detected by a synchro generator. An aimed stopping position for the exchanger, a stop instruction range depending on the distantial operation delay in the control system and the inertia-running distance of the mechanical system, and a coincidence confirmation range depending on the required positioning accuracy are previously set. If there is a difference between the present position and the aimed stopping position, the automatic exchanger is caused to run toward the aimed stopping position. A stop instruction is generated upon arrival at the position within said stop instruction range, and a coincidence confirmation signal is generated upon arrival at the position within the coincidence confirmation range. Since uncertain factors such as operation delay in the control system and the inertia-running distance of the mechanical system that influence the positioning accuracy are made definite by the method of actual measurement or the like and the stop instruction range and the coincidence confirmation range are set based on the measured data, the accuracy for the positioning can be improved. (Ikeda, J.)

  4. Study of the mechanical support and positioning of the sensors for the new tracker of the ALICE experiment at CERN

    CERN Document Server

    AUTHOR|(CDS)2126653; Coli, Silvia

    The Inner Tracking System Detector of the ALICE Experiment at CERN laboratory will be replaced in 2020 with a new detector entirely based on pixel sensor chips. The most critical aspects in the construction of this detector are the precise positioning and the stability of the sensors over time. The work of this thesis starts with the development of a procedure for the positioning of the sensors and has been performed at INFN of Turin. The procedure is split in several steps each of them based on semi-automatic programme to control a Coordinate-Measuring Machine that position the sensors. At the end of the assembly procedure the position of the sensors is verified and recorded such to provide a detailed map. This procedure will be used in five laboratories, four in Europe and one in the United States, where the detector will be assembled. The second part of the work is focused on the mechanical design and analysis of the global support structure of the Inner Tracking System, and has been performed at CERN in c...

  5. Human-Induced Effects on RSS Ranging Measurements for Cooperative Positioning

    DEFF Research Database (Denmark)

    Della Rosa, Francescantonio; Pelosi, Mauro; Nurmi, Jari

    2012-01-01

    of human-induced perturbations for enhancing the final positioning accuracy through cooperative schemes has been assessed. It has been proved that the effect of cooperation is very limited if human factors are not taken into account when performing experimental activities.......We present experimental evaluations of human-induced perturbations on received-signal-strength-(RSS-) based ranging measurements for cooperative mobile positioning. To the best of our knowledge, this work is the first attempt to gain insight and understand the impact of both body loss and hand grip...... on the RSS for enhancing proximity measurements among neighbouring devices in cooperative scenarios. Our main contribution is represented by experimental investigations. Analysis of the errors introduced in the distance estimation using path-loss-based methods has been carried out. Moreover, the exploitation...

  6. Measurements and mathematical formalism of quantum mechanics

    Science.gov (United States)

    Slavnov, D. A.

    2007-03-01

    A scheme for constructing quantum mechanics is given that does not have Hilbert space and linear operators as its basic elements. Instead, a version of algebraic approach is considered. Elements of a noncommutative algebra (observables) and functionals on this algebra (elementary states) associated with results of single measurements are used as primary components of the scheme. On the one hand, it is possible to use within the scheme the formalism of the standard (Kolmogorov) probability theory, and, on the other hand, it is possible to reproduce the mathematical formalism of standard quantum mechanics, and to study the limits of its applicability. A short outline is given of the necessary material from the theory of algebras and probability theory. It is described how the mathematical scheme of the paper agrees with the theory of quantum measurements, and avoids quantum paradoxes.

  7. A new measurement method for electrode gain in an orthogonally symmetric beam position monitor

    International Nuclear Information System (INIS)

    Zou Junying; Wu Fangfang; Yang Yongliang; Sun Baogen; Zhou Zeran; Luo Qing; Lu Ping; Xu Hongliang

    2014-01-01

    The new beam position monitor (BPM) system of the injector at the upgrade project of the Hefei Light Source (HLS Ⅱ) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismaching tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%. (authors)

  8. In-reactor measurements of thermo mechanical behaviour and fission gas release of water reactor fuel

    International Nuclear Information System (INIS)

    Kolstad, E.; Vitanza, C.

    1983-01-01

    the fuel performance during and after a power ramp can be investigated by direct in-pile measurements related to the thermal, mechanical and fission gas release behaviour. The thermal response is examined by thermocouples placed at the centre of the fuel. Such measurements allow the determination of thermal feedback effects induced by the simultaneous liberation of fission gases. The thermal feedback effect is also being separately studied out-of-pile in a specially designed rod where the fission gas release is simulated by injecting xenon in known quantities at different axial positions within the rod. Investigations on the mechanical behaviour are based on axial and diametral cladding deformation measurements. This enables the determination of the amount of local cladding strain and ridging during ramping, the extent of relaxation during the holding time and the amount of residual (plastic) deformation. Gap width measurements are also performed in operating fuel rods using a cladding deflection technique. Fission gas release data are obtained, besides from post-irradiation puncturing, by continuous measurements of the rod internal pressure. This type of measurement leads to the description of the kinetics of the fission gas release process at different powers. The data tend to indicate that the time-dependent release can be reasonably well described by simple diffusion. The paper describes measuring techniques developed and currently in use in Halden, and presents and discusses selected experimental results obtained during various power ramps and transients. (author)

  9. Measurement and quasi-states in quantum mechanics

    International Nuclear Information System (INIS)

    Harper, C.D.

    1987-01-01

    Part of the task of quantum logic is to account for the collapse of the state vector during measurement. A difficulty in this is that it is not obvious how to describe measurement quantum mechanically as the interaction of two or more systems; interacting quantum-mechanical systems do not possess states, so their states cannot collapse. This dissertation shows that component systems of a composite system possess families of state-like vectors. These are the quasi-projections of the state vector of the composite system, each associated with a family of commutable observables. Often these quasi-projections cluster so closely around a quasi-state that they are practically indistinguishable from it. A description of measurement based on quasi-projections reveals the apparent collapse of the state vector during measurement to be illusory. The continuous evolution of the state of the composite system give rise to abrupt changes in the quasi-projections which make it appear that the state has changed. The quasi-projections cease to cluster near one quasi-state, are momentarily scattered, and then cluster again near another quasi-state. The concept of quasi-projection is also used to generalize the quantum logic of Birkhoff and von Neumann in such a fashion that a proposition can always be assigned a truth value

  10. Noise measurements during high-frequency oscillatory and conventional mechanical ventilation.

    Science.gov (United States)

    Berens, R J; Weigle, C G

    1995-10-01

    To evaluate the noise levels with high-frequency oscillatory ventilation and conventional mechanical ventilation. An observational, prospective study. Pediatric intensive care unit. The caretakers and environment of the pediatric intensive care unit. High-frequency oscillatory and conventional mechanical ventilation. Caretakers evaluated noise using a visual analog scale. Noise was measured with a decibel meter and an octave band frequency filter. There was twice as much noise perceived by the caretakers and as measured on the decibel A scale. All measures showed significantly greater noise, especially at low frequencies, with high-frequency oscillatory ventilation. High-frequency oscillatory ventilation exposes the patient to twice as much noise as does the use of conventional mechanical ventilation.

  11. The Transmission mechanisms of the position and Functions of Prophets in Abrahamic Religions

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Vasfi

    2013-09-01

    does not transmit the position and functions of Abraham as much as, it paves the way for the other two mechanism by making Abraham’s children countless and victorious.  The second mechanism of such transmission is heredity: A father’s properties are inherited by the other members of the family, especially by his children, after his death. Although, this mechanism may be too general in its inclusion to be an exclusive mechanism of the prophets, it undergoes a shift of meaning in theology as far as the prophets are concerned. It becomes something more than the mere inheriting of the father’s properties by his children. In such a mechanism, another factor begins to emerge that can be recognized as a kind of supremacy within the family. It is as if some members of the prophet’s family inherit a greater share than other members, and this can lead to their supremacy over the others. Therefore, it can be said that unlike Blessedness, heredity is a mechanism with a hierarchical nature. Compared to the other family relationships, a direct blood-relationship, especially between a father and his son, has a privileged status in heredity. Like Blessedness, heredity begins with Abraham; but unlike Blessedness which was a mechanism introduced by God, heredity is a mechanism introduced by Abraham. What the reports of the Old covenant indicate is that heredity is a more precious and exceptional mechanism than Blessedness, for here the designation of an heir demands first and foremost God’s approval. It is as if by this mechanism, a share of the father’s position and functions are left to the son. But the question is: What of the father’s position and functions and to what measure are transmitted to the son by mechanism of heredity? The answer to this question is to be sought in Moses. Upon knowing his own imminent death, Moses, according to the Old covenant, asks God to appoint a leader for the Israelites, and God chooses Joshua, the son of Nun as Moses’ successor. But

  12. The Transmission mechanisms of the position and Functions of Prophets in Abrahamic Religions

    Directory of Open Access Journals (Sweden)

    S. Roohollah Shafiee

    2013-08-01

    does not transmit the position and functions of Abraham as much as, it paves the way for the other two mechanism by making Abraham’s children countless and victorious.  The second mechanism of such transmission is heredity: A father’s properties are inherited by the other members of the family, especially by his children, after his death. Although, this mechanism may be too general in its inclusion to be an exclusive mechanism of the prophets, it undergoes a shift of meaning in theology as far as the prophets are concerned. It becomes something more than the mere inheriting of the father’s properties by his children. In such a mechanism, another factor begins to emerge that can be recognized as a kind of supremacy within the family. It is as if some members of the prophet’s family inherit a greater share than other members, and this can lead to their supremacy over the others. Therefore, it can be said that unlike Blessedness, heredity is a mechanism with a hierarchical nature. Compared to the other family relationships, a direct blood-relationship, especially between a father and his son, has a privileged status in heredity. Like Blessedness, heredity begins with Abraham; but unlike Blessedness which was a mechanism introduced by God, heredity is a mechanism introduced by Abraham. What the reports of the Old covenant indicate is that heredity is a more precious and exceptional mechanism than Blessedness, for here the designation of an heir demands first and foremost God’s approval. It is as if by this mechanism, a share of the father’s position and functions are left to the son. But the question is: What of the father’s position and functions and to what measure are transmitted to the son by mechanism of heredity? The answer to this question is to be sought in Moses. Upon knowing his own imminent death, Moses, according to the Old covenant, asks God to appoint a leader for the Israelites, and God chooses Joshua, the son of Nun as Moses’ successor. But

  13. The Transmission mechanisms of the position and Functions of Prophets in Abrahamic Religions

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Vasfi

    does not transmit the position and functions of Abraham as much as, it paves the way for the other two mechanism by making Abraham’s children countless and victorious. The second mechanism of such transmission is heredity: A father’s properties are inherited by the other members of the family, especially by his children, after his death. Although, this mechanism may be too general in its inclusion to be an exclusive mechanism of the prophets, it undergoes a shift of meaning in theology as far as the prophets are concerned. It becomes something more than the mere inheriting of the father’s properties by his children. In such a mechanism, another factor begins to emerge that can be recognized as a kind of supremacy within the family. It is as if some members of the prophet’s family inherit a greater share than other members, and this can lead to their supremacy over the others. Therefore, it can be said that unlike Blessedness, heredity is a mechanism with a hierarchical nature. Compared to the other family relationships, a direct blood-relationship, especially between a father and his son, has a privileged status in heredity. Like Blessedness, heredity begins with Abraham; but unlike Blessedness which was a mechanism introduced by God, heredity is a mechanism introduced by Abraham. What the reports of the Old covenant indicate is that heredity is a more precious and exceptional mechanism than Blessedness, for here the designation of an heir demands first and foremost God’s approval. It is as if by this mechanism, a share of the father’s position and functions are left to the son. But the question is: What of the father’s position and functions and to what measure are transmitted to the son by mechanism of heredity? The answer to this question is to be sought in Moses. Upon knowing his own imminent death, Moses, according to the Old covenant, asks God to appoint a leader for the Israelites, and God chooses Joshua, the son of Nun as Moses’ successor. But

  14. The measurement problem in quantum mechanics: A phenomenological investigation

    Science.gov (United States)

    Hunter, Joel Brooks

    2008-10-01

    This dissertation is a phenomenological investigation of the measurement problem in quantum mechanics. The primary subject matter for description and analysis is scientific instruments and their use in experiments which elicit the measurement problem. A methodological critique is mounted against the ontological commitments taken for granted in the canonical interpretations of quantum theory and the scientific activity of measurement as the necessary interface between theoretical interest and perceptual results. I argue that an aesthetic dimension of reality functions as aproto-scientific establishment of sense-making that constantly operates to set integratively all other cognitively neat determinations, including scientifically rendered objects that are intrinsically non-visualizable. The way in which data "key in" to the original and originative register of the sensible in observation is clarified by examining prostheses, measuring apparatuses and instruments that are sense-conveying and -integrative with the human sensorium. Experiments, technology and instrumentation are examined in order to understand how knowing and that which is known is bonded by praxis-aisthesis. Quantum measurement is a praxic-dynamie activity and homologically structured and structur ing functional engagement in terms of instantiation, quantifiability, and spatiotemporal differentiation. The distinctions between a beauty-aesthetic and praxis-aisthesis are delineated. It is argued that a beauty-aesthetic is a construal of the economic dimension of scientific objects and work, and is not the primary manner in which the aesthetic dimension is disclosed. The economic dimension of abstractions reduces to an austere aesthetic of calculative economy. Nature itself, however, is not stingy; it is intrinsically capacious, extravagant, full of surprise, nuance, ambiguity and allusiveness. The capaciousness of Nature and the way in which we are integratively set within Nature in a materiality

  15. On the problem of measurement in quantum mechanics

    International Nuclear Information System (INIS)

    He Zuoxiu

    1993-01-01

    Some new developments in the theory of measurement in quantum mechanics are presented. The theory of measurement given by Von Neumann is shown to be incorrect, since the process of measurement is one of increasing entropy and cannot be derived within the scope of Schroedinger's equation. The new theory developed by Daneri, Loinger and Prosperi can avoid the difficulties previously encountered and, furthermore, can explain the EPR paradox

  16. Emerging interpretations of quantum mechanics and recent progress in quantum measurement

    International Nuclear Information System (INIS)

    Clarke, M L

    2014-01-01

    The focus of this paper is to provide a brief discussion on the quantum measurement process, by reviewing select examples highlighting recent progress towards its understanding. The areas explored include an outline of the measurement problem, the standard interpretation of quantum mechanics, quantum to classical transition, types of measurement (including weak and projective measurements) and newly emerging interpretations of quantum mechanics (decoherence theory, objective reality, quantum Darwinism and quantum Bayesianism). (paper)

  17. Mechanical equipment for magnet measurement and alignment

    International Nuclear Information System (INIS)

    Harvey, A.

    1992-05-01

    The mechanical equipment for measuring and aligning (or fiducializing) magnets is described by reference to devices designed and built by a number of laboratories. Some of these are now available commercially. The descriptions are supplemented by a list of representative sources of hardware

  18. Non-contact and contact measurement system for detecting projectile position in electromagnetic launch bore

    Science.gov (United States)

    Xu, Weidong; Yuan, Weiqun; Xu, Rong; Zhao, Hui; Cheng, Wenping; Zhang, Dongdong; Zhao, Ying; Yan, Ping

    2017-12-01

    This paper introduces a new measurement system for measuring the position of a projectile within a rapid fire electromagnetic launching system. The measurement system contains both non-contact laser shading and metal fiber contact measurement devices. Two projectiles are placed in the rapid fire electromagnetic launch bore, one in the main accelerating segment and the other in the pre-loading segment. The projectile placed in the main accelerating segment should be shot first, and then the other is loaded into the main segment from the pre-loading segment. The main driving current (I-main) can only be discharged again when the second projectile has arrived at the key position (the projectile position corresponds to the discharging time) in the main accelerating segment. So, it is important to be able to detect when the second projectile arrives at the key position in the main accelerating segment. The B-dot probe is the most widely used system for detecting the position of the projectile in the electromagnetic launch bore. However, the B-dot signal is affected by the driving current amplitude and the projectile velocity. There is no current in the main accelerating segment when the second projectile moves into this segment in rapid fire mode, so the B-dot signal for detecting the key position is invalid. Due to the presence of a high-intensity magnetic field, a high current, a high-temperature aluminum attachment, smoke and strong vibrations, it is very difficult to detect the projectile position in the bore accurately. So, other measurements need to be researched and developed in order to achieve high reliability. A measurement system based on a laser (non-contact) and metal fibers (contact) has been designed, and the integrated output signal based on this detector is described in the following paper.

  19. Partial Sleep Deprivation Attenuates the Positive Affective System: Effects Across Multiple Measurement Modalities.

    Science.gov (United States)

    Finan, Patrick H; Quartana, Phillip J; Remeniuk, Bethany; Garland, Eric L; Rhudy, Jamie L; Hand, Matthew; Irwin, Michael R; Smith, Michael T

    2017-01-01

    Ample behavioral and neurobiological evidence links sleep and affective functioning. Recent self-report evidence suggests that the affective problems associated with sleep loss may be stronger for positive versus negative affective state and that those effects may be mediated by changes in electroencepholographically measured slow wave sleep (SWS). In the present study, we extend those preliminary findings using multiple measures of affective functioning. In a within-subject randomized crossover experiment, we tested the effects of one night of sleep continuity disruption via forced awakenings (FA) compared to one night of uninterrupted sleep (US) on three measures of positive and negative affective functioning: self-reported affective state, affective pain modulation, and affect-biased attention. The study was set in an inpatient clinical research suite. Healthy, good sleeping adults (N = 45) were included. Results indicated that a single night of sleep continuity disruption attenuated positive affective state via FA-induced reductions in SWS. Additionally, sleep continuity disruption attenuated the inhibition of pain by positive affect as well as attention bias to positive affective stimuli. Negative affective state, negative affective pain facilitation, nor negative attention bias were altered by sleep continuity disruption. The present findings, observed across multiple measures of affective function, suggest that sleep continuity disruption has a stronger influence on the positive affective system relative to the negative affective affective system. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  20. Development of diverse methods for drop time measurement of PFBR shut down mechanisms

    International Nuclear Information System (INIS)

    Prakash, V.; Nashine, B.K.; Padmakumar, G.; Vijayashree, R.; Sharma, Prashant; Patri, Sudheer; Chandramouli, S.; Rajan, K.K.

    2015-01-01

    Prototype Fast Breeder Reactor (PFBR) is equipped with two shutdown systems namely, Control and Safety Rod Drive Mechanism (CSRDM) and Diverse Safety Rod Drive Mechanism (DSRDM). DSRDM is used for the safe shut down of the reactor. During a SCRAM, DSR is released from its electromagnet and falls into the reactor core under gravity. It is a safety requirement to measure the fall time of DSR during each SCRAM. As no sensor can be attached to the moving part of DSR, non-contact type measurement techniques namely acoustic and eddy current methods are envisaged for the measurement of DSR fall time in PFBR. Acoustic technique uses accelerometer mounted on upper part of DSRDM for the detection of acoustic events during the movement of DSR in the DSR subassembly. Measurements were carried out in various water/sodium facilities and an On-line measurement system for PFBR has been developed. The developed system was tested for its performance and results were compared with ultrasonic method to establish its measurement sensitivity. Eddy current position sensor uses the property of change in inductance due to the entry of DSR piston into the DSR dashpot region. DSR piston, which is made up of modified 9Cr-1Mo steel, replaces the liquid sodium in the dashpot, which results in a change in inductance in the sensor coil embedded in DSR subassembly sheath near the entry of dashpot. A sensor with two pick-up coils was successfully developed and tested in sodium at various temperatures for various test conditions. The developed eddy current system was installed in prototype DSRDM, tested for its performance and the results are compared with acoustic technique. This paper discusses the details of the developmental activities of both the techniques and their experimental verification using prototype DSRDM. (author)

  1. Using RFID Positioning Technology to Construct an Automatic Rehabilitation Scheduling Mechanism.

    Science.gov (United States)

    Wang, Ching-Sheng; Hung, Lun-Ping; Yen, Neil Y

    2016-01-01

    Accurately and efficiently identifying the location of patients during the course of rehabilitation is an important issue. Wireless transmission technology can reach this goal. Tracking technologies such as RFID (Radio frequency identification) can support process improvement and improve efficiencies of rehabilitation. There are few published models or methods to solve the problem of positioning and apply this technology in the rehabilitation center. We propose a mechanism to enhance the accuracy of positioning technology and provide information about turns and obstacles on the path; and user-centered services based on location-aware to enhanced quality care in rehabilitation environment. This paper outlines the requirements and the role of RFID in assisting rehabilitation environment. A prototype RFID hospital support tool is established. It is designed to provide assistance for monitoring rehabilitation patients. It can simultaneously calculate the rehabilitant's location and the duration of treatment, and automatically record the rehabilitation course of the rehabilitant, so as to improve the management efficiency of the rehabilitation program.

  2. Estimation of uncertainty of measurements of 3D mechanisms after kinematic calibration

    International Nuclear Information System (INIS)

    Takamasu, K; Sato, O; Shimojima, K; Takahashi, S; Furutani, R

    2005-01-01

    Calibration methods for 3D mechanisms are necessary to use the mechanisms as coordinate measuring machines. The calibration method of coordinate measuring machine using artifacts, the artifact calibration method, is proposed in taking account of traceability of the mechanism. There are kinematic parameters and form-deviation parameters in geometric parameters for describing the forward kinematic of the mechanism. In this article, the estimation methods of uncertainties using the calibrated coordinate measuring machine after the calibration are formulated. Firstly, the calculation method which takes out the values of kinematic parameters using least squares method is formulated. Secondly, the estimation value of uncertainty of the measuring machine is calculated using the error propagation method

  3. Single-position Hall effect measurements

    DEFF Research Database (Denmark)

    2014-01-01

    A method for determining a distance (Y) between a first position on and an electrical boundary (34) of a test sample by a multi-point probe comprising four contact elements, comprising: contacting the test sample with the four contact elements (20,22,24,26) at the first position, applying a magne...

  4. Two self-referencing methods for the measurement of beam spot position

    International Nuclear Information System (INIS)

    Nyiri, Balazs J.; Smale, Jason R.; Gerig, Lee H.

    2012-01-01

    Purpose: Two quantitative methods of measuring electron beam spot position with respect to the collimator axis of rotation (CAOR) are described. Methods: Method 1 uses a cylindrical ion chamber (IC) mounted on a jig corotational with the collimator making the relationship among the chamber, jaws, and CAOR fixed and independent of collimator angle. A jaw parallel to the IC axis is set to zero and the IC position adjusted so that the IC signal is approximately 50% of the open field value, providing a large dose gradient in the region of the IC. The cGy/MU value is measured as a function of collimator rotation, e.g., every 30°. If the beam spot does not lie on the CAOR, the signal from the ion chamber will vary with collimator rotation. Based on a measured spatial sensitivity, the distance of the beam spot from the CAOR can be calculated from the IC signal variation with rotation. The 2nd method is image based. Two stainless steel rods, 3 mm in diameter, are mounted to a jig attached to the Linac collimator. The rods, offset from the CAOR, lay in different planes normal to the CAOR, one at 158 cm SSD and the other at 70 cm SSD. As the collimator rotates the rods move tangent along an envelope circle, the centers of which are on the CAOR in their respective planes. Three images, each at a different collimator rotation, containing the shadows of both rods, are acquired on the Linac EPID. At each angle the shadow of the rods on the EPID defines lines tangent to the projection of the envelope circles. From these the authors determine the projected centers of the two circles at different heights. From the distance of these two points using the two heights and the source to EPID distance, the authors calculate the distance of the beam spot from the CAOR. Measurements with all two techniques were performed on an Elekta Linac. Measurements were performed with the beam spot in nominal clinical position and in a deliberately offset position. Measurements were also performed

  5. Two self-referencing methods for the measurement of beam spot position

    Energy Technology Data Exchange (ETDEWEB)

    Nyiri, Balazs J.; Smale, Jason R.; Gerig, Lee H. [Ottawa Hospital Cancer Centre, Ottawa K1H 8L6 (Canada) and Faculty of Medicine, University of Ottawa, Ottawa K1H 8M5 (Canada); Elekta Canada, Ottawa, Ontario K1Y 1Z3 (Canada); Ottawa Hospital Cancer Centre, Ottawa K1H 8L6 (Canada); Department of Physics, Carleton University, Ottawa K1S 5B6 (Canada) and Faculty of Medicine, University of Ottawa, Ottawa K1H 8M5 (Canada)

    2012-12-15

    Purpose: Two quantitative methods of measuring electron beam spot position with respect to the collimator axis of rotation (CAOR) are described. Methods: Method 1 uses a cylindrical ion chamber (IC) mounted on a jig corotational with the collimator making the relationship among the chamber, jaws, and CAOR fixed and independent of collimator angle. A jaw parallel to the IC axis is set to zero and the IC position adjusted so that the IC signal is approximately 50% of the open field value, providing a large dose gradient in the region of the IC. The cGy/MU value is measured as a function of collimator rotation, e.g., every 30 Degree-Sign . If the beam spot does not lie on the CAOR, the signal from the ion chamber will vary with collimator rotation. Based on a measured spatial sensitivity, the distance of the beam spot from the CAOR can be calculated from the IC signal variation with rotation. The 2nd method is image based. Two stainless steel rods, 3 mm in diameter, are mounted to a jig attached to the Linac collimator. The rods, offset from the CAOR, lay in different planes normal to the CAOR, one at 158 cm SSD and the other at 70 cm SSD. As the collimator rotates the rods move tangent along an envelope circle, the centers of which are on the CAOR in their respective planes. Three images, each at a different collimator rotation, containing the shadows of both rods, are acquired on the Linac EPID. At each angle the shadow of the rods on the EPID defines lines tangent to the projection of the envelope circles. From these the authors determine the projected centers of the two circles at different heights. From the distance of these two points using the two heights and the source to EPID distance, the authors calculate the distance of the beam spot from the CAOR. Measurements with all two techniques were performed on an Elekta Linac. Measurements were performed with the beam spot in nominal clinical position and in a deliberately offset position. Measurements were also

  6. High-speed 3D surface measurement with mechanical projector

    Science.gov (United States)

    Hyun, Jae-Sang; Zhang, Song

    2017-05-01

    This paper presents a method to overcome the light spectral range limitation of using digital-light-processing (DLP) projector for 3D shape measurement by developing a mechanical projector. The mechanical projector enables much broader spectral range of light than that the DLP projector allows. The rapidly spinning disk with binary structures can generate desired sinusoidal patterns at a frequency of 10 kHz or higher with a single DC motor. By precisely synchronizing the camera with the projector, phase-shifted fringe patterns can be accurately captured for high-accuracy 3D shape measurement. We further employed a computational framework that could enable absolute phase and thus absolute 3D shape measurement. We developed such prototype system that experimentally demonstrated the success of the proposed method.

  7. Development of a computer-assisted system for model-based condylar position analysis (E-CPM).

    Science.gov (United States)

    Ahlers, M O; Jakstat, H

    2009-01-01

    Condylar position analysis is a measuring method for the three-dimensional quantitative acquisition of the position of the mandible in different conditions or at different points in time. Originally, the measurement was done based on a model, using special mechanical condylar position measuring instruments, and on a research scale with mechanical-electronic measuring instruments. Today, as an alternative, it is possible to take measurements with electronic measuring instruments applied directly to the patient. The computerization of imaging has also facilitated condylar position measurement by means of three-dimensional data records obtained by imaging examination methods, which has been used in connection with the simulation and quantification of surgical operation results. However, the comparative measurement of the condylar position at different points in time has so far not been possible to the required degree. An electronic measuring instrument, allowing acquisition of the condylar position in clinical routine and facilitating later calibration with measurements from later examinations by data storage and use of precise equalizing systems, was therefore designed by the present authors. This measuring instrument was implemented on the basis of already existing components from the Reference CPM und Cadiax Compact articulator and registration systems (Gamma Dental, Klosterneuburg, Austria) as well as the matching CMD3D evaluation software (dentaConcept, Hamburg).

  8. Construction of extremal local positive-operator-valued measures under symmetry

    International Nuclear Information System (INIS)

    Virmani, S.; Plenio, M.B.

    2003-01-01

    We study the local implementation of positive-operator-valued measures (POVMs) when we require only the faithful reproduction of the statistics of the measurement outcomes for all initial states. We first demonstrate that any POVM with separable elements can be implemented by a separable superoperator, and develop techniques for calculating the extreme points of POVMs under a certain class of constraint that includes separability and positive partial transposition. As examples we consider measurements that are invariant under various symmetry groups (Werner, isotropic, Bell diagonal, local orthogonal), and demonstrate that in these cases separability of the POVM elements is equivalent to implementability via local operations and classical communication (LOCC). We also calculate the extrema of these classes of measurement under the groups that we consider, and give explicit LOCC protocols for attaining them. These protocols are hence optimal methods for locally discriminating between states of these symmetries. One of many interesting consequences is that the best way to locally discriminate Bell-diagonal mixed states is to perform a two-outcome POVM using local von Neumann projections. This is true regardless of the cost function, the number of states being discriminated, or the prior probabilities. Our results give the first cases of local mixed-state discrimination that can be analyzed quantitatively in full, and may have application to other problems such as demonstrations of nonlocality, experimental entanglement witnesses, and perhaps even entanglement distillation

  9. Quantum mechanical irreversibility and measurement

    CERN Document Server

    Grigolini, P

    1993-01-01

    This book is intended as a tutorial approach to some of the techniques used to deal with quantum dissipation and irreversibility, with special focus on their applications to the theory of measurements. The main purpose is to provide readers without a deep expertise in quantum statistical mechanics with the basic tools to develop a critical judgement on whether the major achievements in this field have to be considered a satisfactory solution of quantum paradox, or rather this ambitious achievement has to be postponed to when a new physics, more general than quantum and classical physics, will

  10. Precision analog signal processor for beam position measurements in electron storage rings

    International Nuclear Information System (INIS)

    Hinkson, J.A.; Unser, K.B.

    1995-05-01

    Beam position monitors (BPM) in electron and positron storage rings have evolved from simple systems composed of beam pickups, coaxial cables, multiplexing relays, and a single receiver (usually a analyzer) into very complex and costly systems of multiple receivers and processors. The older may have taken minutes to measure the circulating beam closed orbit. Today instrumentation designers are required to provide high-speed measurements of the beam orbit, often at the ring revolution frequency. In addition the instruments must have very high accuracy and resolution. A BPM has been developed for the Advanced Light Source (ALS) in Berkeley which features high resolution and relatively low cost. The instrument has a single purpose; to measure position of a stable stored beam. Because the pickup signals are multiplexed into a single receiver, and due to its narrow bandwidth, the receiver is not intended for single-turn studies. The receiver delivers normalized measurements of X and Y position entirely by analog means at nominally 1 V/mm. No computers are involved. No software is required. Bergoz, a French company specializing in precision beam instrumentation, integrated the ALS design m their new BPM analog signal processor module. Performance comparisons were made on the ALS. In this paper we report on the architecture and performance of the ALS prototype BPM

  11. The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.

    Science.gov (United States)

    Zeri, Fabrizio; De Cusatis, Mario; Lupelli, Luigi; Swann, Peter Graham

    2016-01-01

    To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses. Copyright © 2016 The Authors. Published by Elsevier Espana.. All rights reserved.

  12. Effect of standardized orders and provider education on head-of-bed positioning in mechanically ventilated patients.

    Science.gov (United States)

    Helman, Donald L; Sherner, John H; Fitzpatrick, Thomas M; Callender, Marcia E; Shorr, Andrew F

    2003-09-01

    Semirecumbent head-of-bed positioning in mechanically ventilated patients decreases the risk of developing ventilator-associated pneumonia (VAP). The purpose of this study was to determine whether the addition of a standardized order followed by the initiation of a provider education program would increase the frequency with which our patients were maintained in the semirecumbent position. Prospective, pre-, and postintervention observational study. A tertiary care, U.S. Army teaching hospital. Mechanically ventilated medical and surgical intensive care unit patients. The first intervention involved the addition of an order for semirecumbent head-of-bed positioning to our intensive care unit order sets. This was followed 2 months later with a second intervention, which was a nurse and physician education program emphasizing semirecumbent positioning. Data regarding head-of-bed positioning were collected on 100 patient observations at baseline and at 1 and 2 months after each of our interventions. The mean angle of head of bed increased from 24 +/- 9 degrees at baseline to 35 +/- 9 degrees (p 45 degrees increased from 3% to 16% 2 months after the standardized order (p patients with head of bed >45 degrees was 29% (p = NS compared with values after the first intervention). Data collected 6 months after completion of our education programs showed that these improvements were maintained. Standardizing the process of care via the addition of an order specifying head-of-bed position significantly increased the number of patients who were placed in the semirecumbent position. In an era of cost-conscious medicine, interventions that utilize protocols and education programs should be emphasized.

  13. Automation of the positioning of a laser anemometer flow rate measurement bench

    International Nuclear Information System (INIS)

    Gobillot, G.

    1998-01-01

    The laser anemometry technique is commonly used by the Core Hydraulics Laboratory of the CEA for the determination of the field of flow rates inside fuel rod bundles. The adjustment of measurement point coordinates represents an important part of the velocimetry campaign. In order to increase the number of measurements and the preciseness of the positioning operation, the automation of these preliminary tasks was decided. This work describes first the principle of Doppler laser velocimetry, the components of the measurement system and their functioning conditions. Then, the existing software for tuning and measurement is presented. A new software, called PAMELA, for the automatic positioning of the laser anemometer using a moving table with 5 degrees of freedom, has been developed and tested. This software, written with the LabView language, advises the operator, drives the bench and executes the tunings with a greater precision than manually. (J.S.)

  14. Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

    Energy Technology Data Exchange (ETDEWEB)

    Nikneshan, Sima; Emadi, Naghmeh [Dept. of Oral and Maxillofacial Radiology, Dental School, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sharafi, Mohamad [Dept. of Oral and Maxillofacial Radiology, Dental School, Ilam University of Medical Sciences, Ilam (Iran, Islamic Republic of)

    2013-09-15

    This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Two acrylic models were fabricated from a cast with normal occlusion. Straight and 75 degree mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an 8 degree downward tilt of the occlusal plane compared to the standard position, at an 8 degree upward tilt of the anterior occlusal plane, and at a 10 degree downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than 10 degree had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and 8 degree upward tilt of the anterior part of the occlusal plane compared to other positions.

  15. LHC Beam Instrumentation: Beam Position and Intensity Measurements (1/3)

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  16. Realistic thermodynamic and statistical-mechanical measures for neural synchronization.

    Science.gov (United States)

    Kim, Sang-Yoon; Lim, Woochang

    2014-04-15

    Synchronized brain rhythms, associated with diverse cognitive functions, have been observed in electrical recordings of brain activity. Neural synchronization may be well described by using the population-averaged global potential VG in computational neuroscience. The time-averaged fluctuation of VG plays the role of a "thermodynamic" order parameter O used for describing the synchrony-asynchrony transition in neural systems. Population spike synchronization may be well visualized in the raster plot of neural spikes. The degree of neural synchronization seen in the raster plot is well measured in terms of a "statistical-mechanical" spike-based measure Ms introduced by considering the occupation and the pacing patterns of spikes. The global potential VG is also used to give a reference global cycle for the calculation of Ms. Hence, VG becomes an important collective quantity because it is associated with calculation of both O and Ms. However, it is practically difficult to directly get VG in real experiments. To overcome this difficulty, instead of VG, we employ the instantaneous population spike rate (IPSR) which can be obtained in experiments, and develop realistic thermodynamic and statistical-mechanical measures, based on IPSR, to make practical characterization of the neural synchronization in both computational and experimental neuroscience. Particularly, more accurate characterization of weak sparse spike synchronization can be achieved in terms of realistic statistical-mechanical IPSR-based measure, in comparison with the conventional measure based on VG. Copyright © 2014. Published by Elsevier B.V.

  17. Measurement of the length and position of the lower oesophageal sphincter by correlation of external measurements and radiographic estimations in dogs

    International Nuclear Information System (INIS)

    Waterman, A.E.; Hashim, M.A.

    1991-01-01

    Fifty dogs were investigated in order to correlate the length and position of the lower oesophageal sphincter (LOS) with external measurements. Various external measurements were taken while the dogs were anaesthetised and positioned in lateral recumbency. An oesophageal tube was then introduced into the oesophagus and thoracic radiographs were taken. The 'real internal length of the oesophagus' was calculated as the length from the lower jaw incisor tooth to the position of the oesophageal tube at the costal border of the diaphragm. A highly significant linear correlation was found between this internal length and the external length from lower jaw incisor tooth to the anterior border of the head of the 10th rib. Using oesophageal manometry, the length and position of the LOS was also studied in 25 clinically normal bitches. The mean length of the LOS was found to be 4.6 +/- 0.92 cm. The position of the LOS was a mean of 4.4 +/- 1.69 cm cranial to the costal border of the diaphragm. The findings of this study indicate that the external measurements can be used to position catheters for accurate oesophageal manometry in the dog

  18. The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements

    Directory of Open Access Journals (Sweden)

    Naus Krzysztof

    2016-08-01

    Full Text Available The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle by the extended Kalman filter (EKF method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy—PNA are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning.

  19. The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements.

    Science.gov (United States)

    Krzysztof, Naus; Aleksander, Nowak

    2016-08-15

    The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line) system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy-PNA) are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning.

  20. Coordination of two robot manipulators based on position measurements only

    NARCIS (Netherlands)

    Rodriguez Angeles, A.; Nijmeijer, H.

    2001-01-01

    In this note we propose a controller that solves the problem of coordination of two (or more) robots, under a master-slave scheme, in the case when only position measurements are available. The controller consists of a feedback control law, and two non-linear observers. It is shown that the

  1. Mechanical strain can switch the sign of quantum capacitance from positive to negative.

    Science.gov (United States)

    Hanlumyuang, Yuranan; Li, Xiaobao; Sharma, Pradeep

    2014-11-14

    Quantum capacitance is a fundamental quantity that can directly reveal many-body interactions among electrons and is expected to play a critical role in nanoelectronics. One of the many tantalizing recent physical revelations about quantum capacitance is that it can possess a negative value, hence allowing for the possibility of enhancing the overall capacitance in some particular material systems beyond the scaling predicted by classical electrostatics. Using detailed quantum mechanical simulations, we found an intriguing result that mechanical strains can tune both signs and values of quantum capacitance. We used a small coaxially gated carbon nanotube as a paradigmatical capacitor system and showed that, for the range of mechanical strain considered, quantum capacitance can be adjusted from very large positive to very large negative values (in the order of plus/minus hundreds of attofarads), compared to the corresponding classical geometric value (0.31035 aF). This finding opens novel avenues in designing quantum capacitance for applications in nanosensors, energy storage, and nanoelectronics.

  2. Steroid induction of therapy-resistant cytokeratin-5-positive cells in estrogen receptor-positive breast cancer through a BCL6-dependent mechanism

    Science.gov (United States)

    Goodman, C R; Sato, T; Peck, A R; Girondo, M A; Yang, N; Liu, C; Yanac, A F; Kovatich, A J; Hooke, J A; Shriver, C D; Mitchell, E P; Hyslop, T; Rui, H

    2016-01-01

    Therapy resistance remains a major problem in estrogen receptor-α (ERα)-positive breast cancer. A subgroup of ERα-positive breast cancer is characterized by mosaic presence of a minor population of ERα-negative cancer cells expressing the basal cytokeratin-5 (CK5). These CK5-positive cells are therapy resistant and have increased tumor-initiating potential. Although a series of reports document induction of the CK5-positive cells by progestins, it is unknown if other 3-ketosteroids share this ability. We now report that glucocorticoids and mineralocorticoids effectively expand the CK5-positive cell population. CK5-positive cells induced by 3-ketosteroids lacked ERα and progesterone receptors, expressed stem cell marker, CD44, and displayed increased clonogenicity in soft agar and broad drug-resistance in vitro and in vivo. Upregulation of CK5-positive cells by 3-ketosteroids required induction of the transcriptional repressor BCL6 based on suppression of BCL6 by two independent BCL6 small hairpin RNAs or by prolactin. Prolactin also suppressed 3-ketosteroid induction of CK5+ cells in T47D xenografts in vivo. Survival analysis with recursive partitioning in node-negative ERα-positive breast cancer using quantitative CK5 and BCL6 mRNA or protein expression data identified patients at high or low risk for tumor recurrence in two independent patient cohorts. The data provide a mechanism by which common pathophysiological or pharmacologic elevations in glucocorticoids or other 3-ketosteroids may adversely affect patients with mixed ERα+/CK5+ breast cancer. The observations further suggest a cooperative diagnostic utility of CK5 and BCL6 expression levels and justify exploring efficacy of inhibitors of BCL6 and 3-ketosteroid receptors for a subset of ERα-positive breast cancers. PMID:26096934

  3. Maximally-localized position, Euclidean path-integral, and thermodynamics in GUP quantum mechanics

    Science.gov (United States)

    Bernardo, Reginald Christian S.; Esguerra, Jose Perico H.

    2018-04-01

    In dealing with quantum mechanics at very high energies, it is essential to adapt to a quasiposition representation using the maximally-localized states because of the generalized uncertainty principle. In this paper, we look at maximally-localized states as eigenstates of the operator ξ = X + iβP that we refer to as the maximally-localized position. We calculate the overlap between maximally-localized states and show that the identity operator can be expressed in terms of the maximally-localized states. Furthermore, we show that the maximally-localized position is diagonal in momentum-space and that the maximally-localized position and its adjoint satisfy commutation and anti-commutation relations reminiscent of the harmonic oscillator commutation and anti-commutation relations. As application, we use the maximally-localized position in developing the Euclidean path-integral and introduce the compact form of the propagator for maximal localization. The free particle momentum-space propagator and the propagator for maximal localization are analytically evaluated up to quadratic-order in β. Finally, we obtain a path-integral expression for the partition function of a thermodynamic system using the maximally-localized states. The partition function of a gas of noninteracting particles is evaluated. At temperatures exceeding the Planck energy, we obtain the gas' maximum internal energy N / 2 β and recover the zero heat capacity of an ideal gas.

  4. Present and perspective roles of soft X-ray tomography in tokamak plasma position measurements

    International Nuclear Information System (INIS)

    Mlynar, J.; Duval, B.P.; Horacek, J.; Lister, J.B.

    2003-01-01

    This paper shows the importance and feasibility of real-time tomography in fusion experiments for the example of soft X-ray (SXR) position measurements. The requirement of non-magnetic real-time diagnostics in low frequencies for ITER is discussed. This is illustrated by recent results of rapid tomographic inversion of SXR measurements on tokamak TCV. Comparison with the magnetic reconstruction data has not only shown the valuable resolution capabilities of both techniques, but also revealed a slight dependence of magnetic measurements on toroidal magnetic field and an unnoticed drift of plasma position observer. A feasibility study using current hardware capacities for programmable real-time tomographic system with plasma position feedback output was carried out. A compact solution is found to be tractable opening wide perspectives for development

  5. Precision analog signal processor for beam position measurements in electron storage rings

    International Nuclear Information System (INIS)

    Hinkson, J.A.; Unser, K.B.

    1995-01-01

    Beam position monitors (BPM) in electron and positron storage rings have evolved from simple systems composed of beam pickups, coaxial cables, multiplexing relays, and a single receiver (usually a analyzer) into very complex and costly systems of multiple receivers and processors. The older may have taken minutes to measure the circulating beam closed orbit. Today instrumentation designers are required to provide high-speed measurements of the beam orbit, often at the ring revolution frequency. In addition the instruments must have very high accuracy and resolution. A BPM has been developed for the Advanced Light Source (ALS) in Berkeley which features high resolution and relatively low cost. The instrument has a single purpose; to measure position of a stable stored beam. Because the pickup signals are multiplexed into a single receiver, and due to its narrow bandwidth, the receiver is not intended for single-turn studies. The receiver delivers normalized measurements of X and Y posit ion entirely by analog means at nominally 1 V/mm. No computers are involved. No software is required. Bergoz, a French company specializing in precision beam instrumentation, integrated the ALS design m their new BPM analog signal processor module. Performance comparisons were made on the ALS. In this paper we report on the architecture and performance of the ALS prototype BPM

  6. Dual mechanism controls asymmetric spindle position in ascidian germ cell precursors.

    Science.gov (United States)

    Prodon, François; Chenevert, Janet; Hébras, Céline; Dumollard, Rémi; Faure, Emmanuel; Gonzalez-Garcia, Jose; Nishida, Hiroki; Sardet, Christian; McDougall, Alex

    2010-06-01

    Mitotic spindle orientation with respect to cortical polarity cues generates molecularly distinct daughter cells during asymmetric cell division (ACD). However, during ACD it remains unknown how the orientation of the mitotic spindle is regulated by cortical polarity cues until furrowing begins. In ascidians, the cortical centrosome-attracting body (CAB) generates three successive unequal cleavages and the asymmetric segregation of 40 localized postplasmic/PEM RNAs in germ cell precursors from the 8-64 cell stage. By combining fast 4D confocal fluorescence imaging with gene-silencing and classical blastomere isolation experiments, we show that spindle repositioning mechanisms are active from prometaphase until anaphase, when furrowing is initiated in B5.2 cells. We show that the vegetal-most spindle pole/centrosome is attracted towards the CAB during prometaphase, causing the spindle to position asymmetrically near the cortex. Next, during anaphase, the opposite spindle pole/centrosome is attracted towards the border with neighbouring B5.1 blastomeres, causing the spindle to rotate (10 degrees /minute) and migrate (3 microm/minute). Dynamic 4D fluorescence imaging of filamentous actin and plasma membrane shows that precise orientation of the cleavage furrow is determined by this second phase of rotational spindle displacement. Furthermore, in pairs of isolated B5.2 blastomeres, the second phase of rotational spindle displacement was lost. Finally, knockdown of PEM1, a protein localized in the CAB and required for unequal cleavage in B5.2 cells, completely randomizes spindle orientation. Together these data show that two separate mechanisms active during mitosis are responsible for spindle positioning, leading to precise orientation of the cleavage furrow during ACD in the cells that give rise to the germ lineage in ascidians.

  7. High-effective position time spectrometer in actual measurements of low intensity region of electron spectra

    International Nuclear Information System (INIS)

    Babenkov, M.I.; Zhdanov, V.S.

    2002-01-01

    Magnetic position-time spectrometer was proposed in previous work, where not only electron coordinates in focal plane are measured by position sensitive detector (PSD) but places of their birth in beta source plane of a large area are fixed using another PSD, situated behind it, by quick effects, accompanying radioactive decay. PSD on the basis of macro-channel plates are used. It is succeeded in position-time spectrometer to combine beta sources of a large area with multichannel registration for a wide energy interval, that efficiency of measurements was two orders of magnitude increase d in comparison magnetic apparatus having PSD only in focal plane. Owing to two detectors' switching on coincidence the relation effect/background in increased minimum on two orders of magnitude in comparison with the same apparatus. At some complication of mathematical analysis it was obtained, that high characteristics of position-time spectrometer are kept during the use the magnetic field, providing double focusing. Owning to this focusing the gain the efficiency of measurements will make one more order of magnitude. Presented high-effective position-time spectrometer is supposed to use in the measurements of low-intensity region of electron spectra, which are important for development of fundamental physics. This is the first of all estimation of electron anti-neutrino mass by the form of beta spectrum of tritium in the region of boundary energy. Recently here there was problem of non physical negative values. This problem can be solved by using in measurement of different in principle high-effective spectrometers, which possess improved background properties. A position-time spectrometers belongs to these apparatus, which provides the best background conditions at very large effectiveness of the measurements of tritium beta spectrum in the region of boundary energy with acceptable high resolution. An important advantage of position-time spectrometer is the possibility of

  8. Influence of pelvic position on radiographic measurements of the prosthetic acetabular component

    International Nuclear Information System (INIS)

    Thoren, B.; Sahlstedt, B.; Uppsala Univ.

    1990-01-01

    A change in the position of a prosthetic acetabular component between two different radiographic examinations indicates loosening, and may be observed as tilting or migration of the socket. To determine the apparent changes in socket position caused by improper positioning of the pelvis, a full-scale model of a pelvis with attached prosthetic sockets was examined radiographically in different positions. The projected alignment of the Charnley socket indicator wire against the inter-tuberosity line was markedly influenced by the positioning of the pelvis. An alternative way of measuring the alignment is to use the long axis of the projected ellipse of the outer circumferential groove in the socket polyethylene. The thus defined socket alignment was not influenced by the positioning of the pelvis within the investigated range. No apparent socket migration was recorded within the range of pelvic rotation and inclination studied. (orig.)

  9. The error model and experiment of measuring angular position error based on laser collimation

    Science.gov (United States)

    Cai, Yangyang; Yang, Jing; Li, Jiakun; Feng, Qibo

    2018-01-01

    Rotary axis is the reference component of rotation motion. Angular position error is the most critical factor which impair the machining precision among the six degree-of-freedom (DOF) geometric errors of rotary axis. In this paper, the measuring method of angular position error of rotary axis based on laser collimation is thoroughly researched, the error model is established and 360 ° full range measurement is realized by using the high precision servo turntable. The change of space attitude of each moving part is described accurately by the 3×3 transformation matrices and the influences of various factors on the measurement results is analyzed in detail. Experiments results show that the measurement method can achieve high measurement accuracy and large measurement range.

  10. Precise positional measurement system in transcranial magnetic stimulation

    International Nuclear Information System (INIS)

    Inoue, Tomonori; Mishima, Yukuo; Hiwaki, Osamu

    2006-01-01

    Transcranial magnetic stimulation (TMS) is a method for noninvasive stimulation of cerebral cortex, and it has contributed to clinical and basic researches of brain function. In order to estimate the accurate stimulating points of the cortex in TMS, precise measurement of the subject's head and the stimulating coil is necessary. In this study, we have developed the positioning TMS system with a three-dimensional (3-D) digitizer and a multi-articular system. We proposed a method for the accurate measurement of a subject's head and cortex, in which the location data of the subject's face surface captured by a 3-D digitizer were superimposed on the magnetic resonance imaging (MRI) data of the subject's face surface. Using this system, the precise estimation of the stimulated sites of the cortex in TMS was achieved. The validity of the system was verified by the experiment on the TMS of the motor cortex. (author)

  11. Mechanical design for positioning of GM detector for system of avian flu virus detection equipment

    International Nuclear Information System (INIS)

    Rahmat; Budi Santoso; Krismawan; Abdul Jalil

    2010-01-01

    Mechanical design for positioning of GM detector system has been done. It is used for avian flu detection equipment. The requirements for the design are to protect detection system against shock, portable, and easy to maintain. The mechanical system consists of connectors, cable assemblies, holders, casing, housing and detectors cover. The selected material should have small gamma radiation absorption property in order to give optimum counts for the detector. The design result should give a system that is easy to operate, cheap and easy to assemble. (author)

  12. The beam based alignment technique for the measurements of beam position monitors offsets and beam offsets from quadrupoles in the Pohang Light Source

    International Nuclear Information System (INIS)

    Kim, K.H.; Huang, J.Y.; Ko, I.S.

    1999-01-01

    The beam based alignment (BBA) technique is applied to the 2-GeV storage ring of the Pohang Light Source to measure the offsets of beam position monitors. This measurement is particularly necessary for beam position monitors (BPMs) plugged into a long (∼10 m) aluminum chamber, since the mechanical deformation of the vacuum chamber is experienced after repeated heating for the outgassing process, and the BPM positions are changed accordingly. A part of the excitation current of each quadrupole magnet is shunted through an electronic shunt circuit. Then, the closed orbit receives a perturbation due to the current reduction. Using two quadrupole magnets, we can measure the offset of each BPM. Also, the BBA technique is applied to measure the beam offsets from the center of quadrupole magnets, and gives information to the survey team about which quadrupole magnets should be aligned mostly. In this process, we introduce the merit function to reduce various errors such as BPM characteristic changes and the lattice imperfection. By minimizing the merit function, we can get the beam offset as the maximized expectation value. This paper presents the BBA technique used and experimental results taken from the 2-GeV Pohang Light Source (PLS) storage ring. When the BPM offset is measured, it is observed that a 3% of the shunt current is suitable. (author)

  13. Design Modification of Double Acting Positioning Mechanism Inside a Research Reactor Pool

    International Nuclear Information System (INIS)

    El-Bahrawy, A.H.A.

    2002-01-01

    One of the major problems that can face the designers of long actuators is the blocking due to high friction and severe wear of sliding parts, when the case become metal to metal in contact. The present work is an optimum solution for a typical blocking problem that had been raised during the commissioning test of the fission counter three positioning mechanisms inside MPR research reactor at Inshas. A detailed technical investigation had been made in order to define precisely the main reasons behind the problem. High misalignment values of piston and piston rod assembly inside the hydraulic cylinders due to poor design has been discovered to be the main source of the problem. The author has introduced a new design idea, and other mechanisms have been manufactured based on the new design to replace the old ones. The system was tested and found to function with good performance

  14. Accuracy of position measurement method using Arago spot for inertial fusion energy target tracking system

    International Nuclear Information System (INIS)

    Saruta, Koichi; Tsuji, Ryusuke

    2007-01-01

    The accuracy of a position measurement method using the Arago spot is reported for an inertial fusion energy (IFE) target tracking system, where the position of the target is determined by the position of the Arago spot, which is a bright spot appearing in the central portion of the diffraction pattern of a spherical obstacle. We use a He-Ne laser as the light source and a charge-coupled device (CCD) camera with a microscope objective lens to magnify and record the diffraction pattern of a spherical target. We examine two different algorithms to determine the center of the Arago spot in order to compare the measurement performances. The experimental results show that the position of a 5-mm-diameter target can be obtained with a measurement resolution of 1 μm and an rms measurement error of less than 0.2μm for both algorithms when the distance between the target and the microscope objective lens is 5 cm. (author)

  15. Morphological and mechanical analyses of laminates manufactured from randomly positioned carbon fibre/epoxy resin prepreg scraps

    Science.gov (United States)

    Souza, Christiane S. R.; Cândido, Geraldo M.; Alves, Wellington; Marlet, José Maria F.; Rezende, Mirabel C.

    2017-10-01

    This study aims to contribute to sustainability by proposing the reuse of composite prepreg scrap as an added value from discards. The research evaluates the microstructure and mechanical properties of laminates processed by the reuse of uncured carbon fibre/F155-epoxy resin prepreg scraps, waste from the ply cutting area of an aeronautical industry. The composite scraps were used as collected and were randomly positioned to produce laminates to be cured at an autoclave. The mechanical characterization shows a decrease of 39% for the compression property due to the discontinuous fibres in the laminate and an increase of 34% for the interlaminar shear strength, when compared to continuous fibre laminates. This increase is attributed to the higher crosslink density of the epoxy resin, as a result of the cure temperature used in autoclave (60 °C higher than suggested by supplier) and also to the randomly positioned scraps. Microscopic analyses confirm the consolidation of laminates, although show resin rich areas with different sizes and shapes attributed to the overlapping of the scraps with different sizes and shapes. These resin rich areas may contribute to decrease the mechanical properties of laminates. The correlation between mechanical and morphological results shows potential to be used on non-critical structural application, as composite jigs, contributing to sustainability.

  16. Radon Gas Concentration Measurement In Soil For Some Holy Positions In Al-Najaf Al-Ashraf Governorate

    International Nuclear Information System (INIS)

    Hasan, K.H.; Hussain, H.H.

    2014-01-01

    In this search we measurement Radon gas concentration in the soil of holy positions in Al-Najaf Al-Ashraf city.We choice it for honorable position in all the world and, because millions of peoples and religious sciences students visit it.we selected 23 positions .By using a short-term way in modern technology its (RAD7) to measured concentration for depths (10,30,50,70)cm in all the holy positions.All the concentration in position studies within the range allowed of the global

  17. Test measurement of a new TESLA cavity beam position monitor at the ELBE linac

    International Nuclear Information System (INIS)

    Sargsyan, V.; Schreiber, H.J.; Evtushenko, P.; Schurig, R.

    2004-01-01

    A new type of a cavity BPM proposed for beam position determination along the TESLA linac was tested at the accelerator ELBE in Rossendorf / Dresden. Measurements using an improved BPM (large and stable cross-talk isolation, significantly less energy dissipation, a novel LO signal generation) were performed in single- and multi-bunch regimes. Agreement with expectations was found. The low bunch charge available allowed for preliminary measurements on sensitivity and position resolution, which extrapolated to TESLA would ful l the demands for precise bunch-to-bunch position determination. Possible improvements, in particular on the signal processing scheme, are also discussed. (orig.)

  18. The effect of the nuclear track detectors' position on the radon concentration measurements

    International Nuclear Information System (INIS)

    Yilmaz, A.; Kuerkcueoglu, M. E.; Haner, B.

    2009-01-01

    It is important to determine the radon concentration values of the underground mines according to workers' health. For this purpose, to be able to measure radon concentrations by using passive nuclear etched track detectors, CR-39 detectors were placed into 66 points on the way of aeration galleries of Armutcuk, Amasra, Karadon, Kozlu and Uezuelmez bituminous coal mines which are known as the Carboniferous outcrops of the Western Black Sea Area in Turkey. In every measurement point, a pair of detectors, one of them is being perpendicular and the other one is parallel to air flow, were exposed to radon gases over 40 days for four seasons of the year 2008. The relationship between the readings of vertically and horizontally positioned detectors was investigated by evaluating the effect of the detectors' positions on the detected radon concentrations. It can be concluded that, the vertically positioned detectors, in general, recorded higher radon gases concentration values than that of the horizontally positioned ones.

  19. Nasal obstruction and sleep-disordered breathing: the effect of supine body position on nasal measurements in snorers.

    Science.gov (United States)

    Virkkula, Paula; Maasilta, Paula; Hytönen, Maija; Salmi, Tapani; Malmberg, Henrik

    2003-06-01

    Nasal obstruction is considered to be a potential etiological factor in sleep-disordered breathing. However, a significant correlation between nasal measurements and obstructive sleep apnea has not been demonstrated so far. The aim of this study was to investigate the relationships between nasal resistance, nasal volumes and selected sleep parameters using nasal measurements performed in both seated and supine positions. We also investigated whether snoring patients in our clinical sample showed increased positional or decongestive nasal mucosal changes. Forty-one snoring men on a waiting list for correction of nasal obstruction underwent polysomnography, anterior rhinomanometry and acoustic rhinometry. Nineteen non-snoring control subjects were also recruited. Nasal measurements were performed in a seated position, after lying down in a supine position and, after decongestion of nasal mucosa, in a seated position again. In the overall patient group, nasal volume at a distance 2-4 cm from the nares in the supine position correlated inversely with apnea-hypopnea index (AHI) (r = -0.32, p patients, total nasal resistance measured in a supine position correlated with AHI (r = 0.50, p position and sleep parameters. Postural or decongestive changes in nasal measurements were not increased in snoring patients compared with control subjects. The relationship found between nasal measurements and sleep parameters suggests that nasal obstruction does augment airway collapse.

  20. Magnet Fiducialization with Coordinate Measuring Machines

    Energy Technology Data Exchange (ETDEWEB)

    Friedsam, H.; Oren, W.; Pietryka, M.; /SLAC

    2005-08-12

    One of the fundamental alignment problems encountered when building a particle accelerator is the transfer of a component's magnetic centerline position to external fiducials. This operation, dubbed fiducialization, is critical because it can contribute significantly to the alignment error budget. The fiducialization process requires two measurements: (1) from magnetic centerline to mechanical centerline, and (2) from mechanical centerline to external fiducials. This paper will focus on methods for observing the second measurement. Two Stanford Linear Collider (SLC) examples are presented. The object of magnet fiducialization is to relate the magnet-defined beamline position to exterior reference surfaces. To be useful for later component alignment, this relationship must be established in a manner consistent with overall positioning tolerances. The error budget for the SLC's {+-} 100 {micro}m component to component alignment tolerance is as follows: magnetic centerline to mechanical centerline--{sigma} = {+-}30 {micro}m; mechanical centerline to fiducial marks--{sigma} = {+-}50 {micro}m; and fiducial marks to adjacent components--{sigma} = {+-}80 {micro}m; the TOTAL {sigma} = {+-}100 {micro}m. The offset between the mechanical and magnetic centerlines of well-known magnets is generally smaller than the {+-}30 {micro}m measurement tolerance. It is commonly assumed to be zero without measurement. When this tiny value must be measured, extreme care is necessary to avoid obscuring the offset with measurement tool registration errors. In contrast, the mechanical centerline to fiducial measurement must be performed on every magnet. The 50 {micro}m tolerance for this operation is only slightly larger and pushes conventional surveying technology to its limit.

  1. Magnet Fiducialization with Coordinate Measuring Machines

    International Nuclear Information System (INIS)

    Friedsam, H.; Oren, W.; Pietryka, M.; SLAC

    2005-01-01

    One of the fundamental alignment problems encountered when building a particle accelerator is the transfer of a component's magnetic centerline position to external fiducials. This operation, dubbed fiducialization, is critical because it can contribute significantly to the alignment error budget. The fiducialization process requires two measurements: (1) from magnetic centerline to mechanical centerline, and (2) from mechanical centerline to external fiducials. This paper will focus on methods for observing the second measurement. Two Stanford Linear Collider (SLC) examples are presented. The object of magnet fiducialization is to relate the magnet-defined beamline position to exterior reference surfaces. To be useful for later component alignment, this relationship must be established in a manner consistent with overall positioning tolerances. The error budget for the SLC's ± 100 (micro)m component to component alignment tolerance is as follows: magnetic centerline to mechanical centerline--σ = ±30 (micro)m; mechanical centerline to fiducial marks--σ = ±50 (micro)m; and fiducial marks to adjacent components--σ = ±80 (micro)m; the TOTAL σ = ±100 (micro)m. The offset between the mechanical and magnetic centerlines of well-known magnets is generally smaller than the ±30 (micro)m measurement tolerance. It is commonly assumed to be zero without measurement. When this tiny value must be measured, extreme care is necessary to avoid obscuring the offset with measurement tool registration errors. In contrast, the mechanical centerline to fiducial measurement must be performed on every magnet. The 50 (micro)m tolerance for this operation is only slightly larger and pushes conventional surveying technology to its limit

  2. Indirect and two fold measurements in quantum mechanics

    International Nuclear Information System (INIS)

    Fer, Francis

    1981-01-01

    Keeping strictly in the positivist, probabilistic and hilbertian frame of quantum mechanics, the author develops a criticism of the accepted theory of indirect and twofold measurements. He shows that this theory cannot logically derive from the usual axiomatics, namely from the so-called reduction-of-state axiom. He proposes a modified statement (already used sometimes) of this axiom, which leads to a reliable theory of indirect and twofold measurements. The results are particularly: a) that a measurement made on a sub-system does not modify the mathematical representation of the complementary system, nor its prior probability distributions; b) that measurement is nothing else than an information which enables to correct the probabilities of further measurements according to the classical rules of the calculus of probabilities [fr

  3. Beam Optics Measurements Through Turn by Turn Beam Position Data in the SLS

    CERN Document Server

    Zisopoulos, P; Streun, A; Ziemann, v

    2013-01-01

    Refined Fourier analysis of turn-by-turn (TBT) transverse position data measurements can be used for determining several beam properties of a ring, such as transverse tunes, optics functions, phases, chromatic properties and coupling. In particular, the Numerical Analysis of Fundamental Frequencies (NAFF) algorithm is used to analyse TBT data from the Swiss Light Source (SLS) storage ring in order to estimate on and off-momentum beam characteristics. Of particular interest is the potential of using the full position information within one turn in order to measure beam optics properties.

  4. Phase and synchronous detector theory as applied to beam position and intensity measurements

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1995-01-01

    A popular signal processing technique for beam position measurements uses the principle of amplitude-to-phase (AM/PM) conversion and phase detection. This technique processes position-sensitive beam-image-current probe-signals into output signals that are proportional to the beam's position. These same probe signals may be summed and processed in a different fashion to provide output signals that are proportional to the peak beam current which is typically referred to as beam intensity. This paper derives the transfer functions for the AM/PM beam position and peak beam current processors

  5. Protocol for fermionic positive-operator-valued measures

    Science.gov (United States)

    Arvidsson-Shukur, D. R. M.; Lepage, H. V.; Owen, E. T.; Ferrus, T.; Barnes, C. H. W.

    2017-11-01

    In this paper we present a protocol for the implementation of a positive-operator-valued measure (POVM) on massive fermionic qubits. We present methods for implementing nondispersive qubit transport, spin rotations, and spin polarizing beam-splitter operations. Our scheme attains linear opticslike control of the spatial extent of the qubits by considering ground-state electrons trapped in the minima of surface acoustic waves in semiconductor heterostructures. Furthermore, we numerically simulate a high-fidelity POVM that carries out Procrustean entanglement distillation in the framework of our scheme, using experimentally realistic potentials. Our protocol can be applied not only to pure ensembles with particle pairs of known identical entanglement, but also to realistic ensembles of particle pairs with a distribution of entanglement entropies. This paper provides an experimentally realizable design for future quantum technologies.

  6. Positive Operator Valued Measures: A General Setting for Frames

    OpenAIRE

    Moran, Bill; Howard, Stephen; Cochran, Doug

    2011-01-01

    This paper presents an overview of close parallels that exist between the theory of positive operator-valued measures (POVMs) associated with a separable Hilbert space and the theory of frames on that space, including its most important generalizations. The concept of a framed POVM is introduced, and classical frames, fusion frames, generalized frames, and other variants of frames are all shown to to arise as framed POVMs. This observation allows drawing on a rich existing theory of POVMs to ...

  7. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  8. An extended set-value observer for position estimation using single range measurements

    DEFF Research Database (Denmark)

    Marcal, Jose; Jouffroy, Jerome; Fossen, Thor I.

    the observability of the system is briefly discussed and an extended set-valued observer is presented, with some discussion about the effect of the measurements noise on the final solution. This observer estimates bounds in the errors assuming that the exogenous signals are bounded, providing a safe region......The ability of estimating the position of an underwater vehicle from single range measurements is important in applications where one transducer marks an important geographical point, when there is a limitation in the size or cost of the vehicle, or when there is a failure in a system...... of transponders. The knowledge of the bearing of the vehicle and the range measurements from a single location can provide a solution which is sensitive to the trajectory that the vehicle is following, since there is no complete constraint on the position estimate with a single beacon. In this paper...

  9. Mechanical seal monitoring technique by acoustic emission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tadashi; Fujita, Yoshihiro; Kawaguchi, Kazunori; Saito, Kazuhiro; Yokota, Setsuo; Hisada, Yasuhide; Masahiro, Komatsu

    1987-09-20

    This report describes a technique for mechanical seal monitoring through acoustic emission (AE) measurement. The equipment consists of an AE sensor, preamplifier, multiplexer, main amplifier, effective value transducer and computer system. When the sealed liquid pressure undergoes a large change, the seal surface configuration is monitored and evaluated accurately through AE measurement. If the mechanical seal surface id damaged or worn, the AE level is kept high or continues to fluctuate largely for a rather long period. When leak occurs, the AE value shows great fluctuations either at extremely low levels or at high levels. The former trend is considered to result from a decrease in solid contact due to an excessive amount of liquid film being formed at the seal surface during leak. In the latter case, the leak is attributed to severe damage to the seal surface. (18 figs, 1 tab, 5 photos, 3 refs)

  10. Hybrid integrated sensor for position measurement

    International Nuclear Information System (INIS)

    Schmidt, B.; Schott, H.; Just, H.-J.

    1986-01-01

    The design, fabrication and performance of an integrated two-dimensional position sensitive photodetector are presented. The optoelectronic device used as sensitive element in the circuit is a full area position sensitive photodiode (PPD) with high linearity over the full sensitive area. The PPD is integrated with the analog electronics in a hybrid circuit using thick film technology. The analog electronics includes the signal amplification and the signal conditioning to form the output signals proportional to the light beam center position at the sensor surface and an output signal proportional to the light beam intensity. Using hybrid integration a new position sensitive transducer is developed giving output signals, transmiting in large distances without problems and driving directly actuators in any control system

  11. Measuring implicit attitudes: A positive framing bias flaw in the Implicit Relational Assessment Procedure (IRAP).

    Science.gov (United States)

    O'Shea, Brian; Watson, Derrick G; Brown, Gordon D A

    2016-02-01

    How can implicit attitudes best be measured? The Implicit Relational Assessment Procedure (IRAP), unlike the Implicit Association Test (IAT), claims to measure absolute, not just relative, implicit attitudes. In the IRAP, participants make congruent (Fat Person-Active: false; Fat Person-Unhealthy: true) or incongruent (Fat Person-Active: true; Fat Person-Unhealthy: false) responses in different blocks of trials. IRAP experiments have reported positive or neutral implicit attitudes (e.g., neutral attitudes toward fat people) in cases in which negative attitudes are normally found on explicit or other implicit measures. It was hypothesized that these results might reflect a positive framing bias (PFB) that occurs when participants complete the IRAP. Implicit attitudes toward categories with varying prior associations (nonwords, social systems, flowers and insects, thin and fat people) were measured. Three conditions (standard, positive framing, and negative framing) were used to measure whether framing influenced estimates of implicit attitudes. It was found that IRAP scores were influenced by how the task was framed to the participants, that the framing effect was modulated by the strength of prior stimulus associations, and that a default PFB led to an overestimation of positive implicit attitudes when measured by the IRAP. Overall, the findings question the validity of the IRAP as a tool for the measurement of absolute implicit attitudes. A new tool (Simple Implicit Procedure:SIP) for measuring absolute, not just relative, implicit attitudes is proposed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  12. Characterization of positional errors and their influence on micro four-point probe measurements on a 100 nm Ru film

    DEFF Research Database (Denmark)

    Kjær, Daniel; Hansen, Ole; Østerberg, Frederik Westergaard

    2015-01-01

    Thin-film sheet resistance measurements at high spatial resolution and on small pads are important and can be realized with micrometer-scale four-point probes. As a result of the small scale the measurements are affected by electrode position errors. We have characterized the electrode position...... errors in measurements on Ru thin film using an Au-coated 12-point probe. We show that the standard deviation of the static electrode position error is on the order of 5 nm, which significantly affects the results of single configuration measurements. Position-error-corrected dual......-configuration measurements, however, are shown to eliminate the effect of position errors to a level limited either by electrical measurement noise or dynamic position errors. We show that the probe contact points remain almost static on the surface during the measurements (measured on an atomic scale) with a standard...

  13. Condylar position analysis with a new electronic condylar position measuring instrument E-CPM: influence of different examiners and a working bite on reproducibility.

    Science.gov (United States)

    Vahle-Hinz, K; Rybczynski, A; Jakstat, H; Ahlers, M O

    2009-01-01

    Condylar position analysis facilitates a quantitative comparison of the condylar position with and without a bite record, different records and changed influencing factors. Handling by the examiner when positioning the model is a significant factor with regard to the accuracy of the examination. Measurement accuracy could be improved when positioning the models by using special working bites, hence the objective of the experiments described in this study consisted in examining the extent to which the measuring results are influenced by different examiners and by using working bites. In the first trial, one examiner performed ten measurements without and with an interposed working bite for five model pairs in each case. In the second trial, nine examiners (three specialized dentists, three dental assistants, three students) performed ten measurements in each case without and with an interposed working bite. The three-dimensional position was read digitally with the E-CPM (Gamma Dental, Klosterneuburg/Vienna, Austria), recorded by means of spreadsheet software (Microsoft Excel) and diagnostic software (CMDfact, CMD3D module, dentaConcept, Hamburg), and evaluated with graphing software (Sigma Plot, Systat Software, USA). In the first trial, it was shown that the reproducibility of mounting was improved markedly (p <0.01) by using bite records in the form of working bites. In the second trial, it was shown that the mean error increased significantly (p <0.01) when several examiners performed the measurements compared with the results of one examiner alone. No significantly different results occurred (p < 0.01) in the comparison of the different groups of examiners with different educational and training backgrounds. This applied for the mounting methods without and with working bite. On the other hand, the reproducibility of mounting improved distinctly (p<0.01) in every group of examiners when working bites were used. Reproducibility of condylar position analysis was

  14. An Evaluation of the Measurement Properties of the Five Cs Model of Positive Youth Development.

    Science.gov (United States)

    Conway, Ronan J; Heary, Caroline; Hogan, Michael J

    2015-01-01

    There is growing recognition of the need to develop acceptable measures of adolescent's positive attributes in diverse contexts. The current study evaluated the measurement properties of the Five Cs model of Positive Youth Development (PYD) scale (Lerner et al., 2005) using a sample of 672 Irish adolescents. Confirmatory factor analyses indicated that a five-factor model provided a good fit to the data. The internal reliability and construct validity of the Five Cs model were supported, with character the strongest predictor of contribution, while connection was the strongest predictor of risky-behaviors. Notably, confidence was significantly negatively related to contribution, and positively related to risky-behaviors. Multi-group hierarchical nested models supported measurement invariance across early- (11-14 years) and late- (15-19 years) adolescent age groups, with partial invariance found across gender. Younger adolescents evinced higher PYD, while PYD was associated with higher contribution and lower depression and risk-behaviors across all groups. The application of the PYD framework as a measure of positive functioning across adolescence is discussed.

  15. Research on corrosion mechanism of suspension insulator steel foot of direct current system and measures for corrosion inhibition

    Science.gov (United States)

    Chen, He; Yang, Yueguang; Su, Guolei; Wang, Xiaoqing; Zhang, Hourong; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    There are increasingly serious electrocorrosion phenomena on insulator hardware caused by direct current transmission due to the wide-range popularization of extra high voltage direct current transmission engineering in our country. Steel foot corrosion is the main corrosion for insulators on positive polarity side of transmission lines. On one hand, the corrosion leads to the tapering off of steel foot diameter, having a direct influence on mechanical property of insulators; on the other hand, in condition of corrosion on steel foot wrapped in porcelain ware, the volume of the corrosion product is at least 50% more than that of the original steel foot, leading to bursting of porcelain ware, threatening safe operation of transmission lines. Therefore, it is necessary to conduct research on the phenomenon and propose feasible measures for corrosion inhibition. Starting with the corrosion mechanism, this article proposes two measures for corrosion inhibition, and verifies the inhibition effect in laboratory conditions, providing reference for application in engineering.

  16. A method for measuring plasma position in TJ-I Tokamak

    International Nuclear Information System (INIS)

    Quin, J.; TJ-I Team.

    1993-01-01

    A method using pairs of Mirnov coils to measure the plasma position in TJ-I is presented. The simple toroidal filament model which neglects the effect of plasma current density profile has proven to be acceptable within the experimental accuracy. The effect of plasma current density profile remains to be small, if the plasma current density profile has a quadratic form. (Author)

  17. The development of small-scale mechanization means positioning algorithm using radio frequency identification technology in industrial plants

    Science.gov (United States)

    Astafiev, A.; Orlov, A.; Privezencev, D.

    2018-01-01

    The article is devoted to the development of technology and software for the construction of positioning and control systems for small mechanization in industrial plants based on radio frequency identification methods, which will be the basis for creating highly efficient intelligent systems for controlling the product movement in industrial enterprises. The main standards that are applied in the field of product movement control automation and radio frequency identification are considered. The article reviews modern publications and automation systems for the control of product movement developed by domestic and foreign manufacturers. It describes the developed algorithm for positioning of small-scale mechanization means in an industrial enterprise. Experimental studies in laboratory and production conditions have been conducted and described in the article.

  18. Measurement of gastric emptying time in various positions using sup(99m)Tc-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Shibatsuji, H; Hamada, S; Takahashi, H; Ohishi, H; Hachiya, T [Nara Medical Univ., Kashihara (Japan)

    1976-04-01

    Gastric emptying with the patients in various positions was evaluated in a group of 8 volunteers by means of serial recordings of gastric radioactivity after administration of a test meal labelled with sup(99m)Tc-DTPA. Gastric emptying time was measured in the supine, prone and sitting position, and the time, which differed according to the position, was expressed as a half life (T1/2) of meal in the stomach. Emptying time was shorter in the prone position and longer in the supine position.

  19. Mechanical Design of the Intensity Measurement Devices for the LHC

    CERN Document Server

    Belorhad, D; Odier, P; Thoulet, S

    2008-01-01

    The intensity measurement for the LHC ring is provided by eight current transformers (2×DCCT, 2×FBCT per beam). The measurement resolution of 1?Arms at 1s average for the DCCTs and ±10^9p in 25ns for the FBCTs is required. Such constraints call for low noise electronics and a compact magnetically shielded mechanical design. Correct integration of these devices into the vacuum system also requires the vacuum chambers equipped with the non-evaporable getter (NEG) film. The NEG is activated by heating the vacuum chamber to 200?C and more. Such temperatures affect the structure of the magnetic materials, which form the base part of the intensity measurement devices, and degrade their performace. A cooling circuit is needed. Due to the mechanical constraints, the cooling circuit, as well as heating element must form an integral part of the design. The aim of this paper is to present the solutions to these problems and discuss the mechanical construction of the DCCTs and FBCTs currently being installed in the LH...

  20. Measurement properties of exsisting clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, B; Lund, H

    (COSMIN checklist), the methodological quality in the reliability and validity domains was ‘fair’ (57%) to ‘poor’ (43%), with only one study rated as ‘good’. The reliability domain was most often investigated. Fewof the assessment methods in the included studies that had ‘fair’ or ‘good’ measurement......MEASUREMENT PROPERTIES OF EXISTING CLINICAL ASSESSMENT METHODS EVALUATING SCAPULAR POSITIONING AND FUNCTION. A SYSTEMATIC REVIEW1,2Camilla Marie Larsen, 1,3Birgit Juul-Kristensen, 1,3Hans Lund, 1Karen Søgaard1Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark2......,2]. Rehabilitation exercises are aiming at altering abnormal/asymmetric scapular positioning and/or function. Numerous assessment methods have measured the degree of scapular dyskinesis, subjectively by visual evaluation and objectively by measurements of static and dynamic scapular positioning, by either a 3...

  1. HF Radio Angle-of-Arrival Measurements and Ionosonde Positioning

    Directory of Open Access Journals (Sweden)

    Lung-Chih Tsai

    2014-01-01

    Full Text Available Since 2010 a 2nd generation NOAA MF/HF radar, also referred to as the VIPIR ionosonde, has been operated at Hualien, Taiwan (23.8973°N, 121.5503°E. The Hualien VIPIR ionosonde is a modern ionospheric radar, fully digitizing complex signal records and using multiple parallel receiver channels for simultaneous signal measurements from multiple spaced receiving antennas. This paper considers radio direction finding based on interferometric phase measurements from a horizontal antenna array in the Hualien VIPIR ionosonde system. We applied the Hermite normal form method to solve the phase-measurement aliasing and least squares problems and improve the radio angle-of-arrival (AOA measurements. Backward ray-tracing simulation has been proposed to determine radio transmitter position. This paper presents a numerical, step by step ray-tracing method based on the IGRF superimposed onto a phenomenological ionospheric electron density model, the TaiWan Ionospheric Model (TWIM. The proposed methodology is successfully applied to locate two experimental HF radio transmitters at Longquan and Chungli with distance errors within 5 km and less than 5% of the great circle distances.

  2. Study on the three-station typical network deployments of workspace Measurement and Positioning System

    Science.gov (United States)

    Xiong, Zhi; Zhu, J. G.; Xue, B.; Ye, Sh. H.; Xiong, Y.

    2013-10-01

    As a novel network coordinate measurement system based on multi-directional positioning, workspace Measurement and Positioning System (wMPS) has outstanding advantages of good parallelism, wide measurement range and high measurement accuracy, which makes it to be the research hotspots and important development direction in the field of large-scale measurement. Since station deployment has a significant impact on the measurement range and accuracy, and also restricts the use-cost, the optimization method of station deployment was researched in this paper. Firstly, positioning error model was established. Then focusing on the small network consisted of three stations, the typical deployments and error distribution characteristics were studied. Finally, through measuring the simulated fuselage using typical deployments at the industrial spot and comparing the results with Laser Tracker, some conclusions are obtained. The comparison results show that under existing prototype conditions, I_3 typical deployment of which three stations are distributed in a straight line has an average error of 0.30 mm and the maximum error is 0.50 mm in the range of 12 m. Meanwhile, C_3 typical deployment of which three stations are uniformly distributed in the half-circumference of an circle has an average error of 0.17 mm and the maximum error is 0.28 mm. Obviously, C_3 typical deployment has a higher control effect on precision than I_3 type. The research work provides effective theoretical support for global measurement network optimization in the future work.

  3. Measurement of residual stresses using fracture mechanics weight functions

    International Nuclear Information System (INIS)

    Fan, Y.

    2000-01-01

    A residual stress measurement method has been developed to quantify through-the-thickness residual stresses. Accurate measurement of residual stresses is crucial for many engineering structures. Fabrication processes such as welding and machining generate residual stresses that are difficult to predict. Residual stresses affect the integrity of structures through promoting failures due to brittle fracture, fatigue, stress corrosion cracking, and wear. In this work, the weight function theory of fracture mechanics is used to measure residual stresses. The weight function theory is an important development in computational fracture mechanics. Stress intensity factors for arbitrary stress distribution on the crack faces can be accurately and efficiently computed for predicting crack growth. This paper demonstrates that the weight functions are equally useful in measuring residual stresses. In this method, an artificial crack is created by a thin cut in a structure containing residual stresses. The cut relieves the residual stresses normal to the crack-face and allows the relieved residual stresses to deform the structure. Strain gages placed adjacent to the cut measure the relieved strains corresponding to incrementally increasing depths of the cut. The weight functions of the cracked body relate the measured strains to the residual stresses normal to the cut within the structure. The procedure details, such as numerical integration of the singular functions in applying the weight function method, will be discussed

  4. Measurement of residual stresses using fracture mechanics weight functions

    International Nuclear Information System (INIS)

    Fan, Y.

    2001-01-01

    A residual stress measurement method has been developed to quantify through-the-thickness residual stresses. Accurate measurement of residual stresses is crucial for many engineering structures. Fabrication processes such as welding and machining generate residual stresses that are difficult to predict. Residual stresses affect the integrity of structures through promoting failures due to brittle fracture, fatigue, stress corrosion cracking, and wear. In this work, the weight function theory of fracture mechanics is used to measure residual stresses. The weight function theory is an important development in computational fracture mechanics. Stress intensity factors for arbitrary stress distribution on the crack faces can be accurately and efficiently computed for predicting crack growth. This paper demonstrates that the weight functions are equally useful in measuring residual stresses. In this method, an artificial crack is created by a thin cut in a structure containing residual stresses. The cut relieves the residual stresses normal to the crack-face and allows the relieved residual stresses to deform the structure. Strain gages placed adjacent to the cut measure the relieved strains corresponding to incrementally increasing depths of the cut. The weight functions of the cracked body relate the measured strains to the residual stresses normal to the cut within the structure. The procedure details, such as numerical integration of the singular functions in applying the weight function method, will be discussed. (author)

  5. Amplification of ABA biosynthesis and signaling through a positive feedback mechanism in seeds.

    Science.gov (United States)

    Nonogaki, Mariko; Sall, Khadidiatou; Nambara, Eiji; Nonogaki, Hiroyuki

    2014-05-01

    Abscisic acid is an essential hormone for seed dormancy. Our previous study using the plant gene switch system, a chemically induced gene expression system, demonstrated that induction of 9-cis-epoxycarotenoid dioxygenase (NCED), a rate-limiting ABA biosynthesis gene, was sufficient to suppress germination in imbibed Arabidopsis seeds. Here, we report development of an efficient experimental system that causes amplification of NCED expression during seed maturation. The system was created with a Triticum aestivum promoter containing ABA responsive elements (ABREs) and a Sorghum bicolor NCED to cause ABA-stimulated ABA biosynthesis and signaling, through a positive feedback mechanism. The chimeric gene pABRE:NCED enhanced NCED and ABF (ABRE-binding factor) expression in Arabidopsis Columbia-0 seeds, which caused 9- to 73-fold increases in ABA levels. The pABRE:NCED seeds exhibited unusually deep dormancy which lasted for more than 3 months. Interestingly, the amplified ABA pathways also caused enhanced expression of Arabidopsis NCED5, revealing the presence of positive feedback in the native system. These results demonstrated the robustness of positive feedback mechanisms and the significance of NCED expression, or single metabolic change, during seed maturation. The pABRE:NCED system provides an excellent experimental system producing dormant and non-dormant seeds of the same maternal origin, which differ only in zygotic ABA. The pABRE:NCED seeds contain a GFP marker which enables seed sorting between transgenic and null segregants and are ideal for comparative analysis. In addition to its utility in basic research, the system can also be applied to prevention of pre-harvest sprouting during crop production, and therefore contributes to translational biology. © 2014 The Authors The Plant Journal © 2014 John Wiley & Sons Ltd.

  6. Degradation of lithium ion batteries employing graphite negatives and nickel-cobalt-manganese oxide + spinel manganese oxide positives: Part 2, chemical-mechanical degradation model

    Science.gov (United States)

    Purewal, Justin; Wang, John; Graetz, Jason; Soukiazian, Souren; Tataria, Harshad; Verbrugge, Mark W.

    2014-12-01

    Capacity fade is reported for 1.5 Ah Li-ion batteries containing a mixture of Li-Ni-Co-Mn oxide (NCM) + Li-Mn oxide spinel (LMO) as positive electrode material and a graphite negative electrode. The batteries were cycled at a wide range of temperatures (10 °C-46 °C) and discharge currents (0.5C-6.5C). The measured capacity losses were fit to a simple physics-based model which calculates lithium inventory loss from two related mechanisms: (1) mechanical degradation at the graphite anode particle surface caused by diffusion-induced stresses (DIS) and (2) chemical degradation caused by lithium loss to continued growth of the solid-electrolyte interphase (SEI). These two mechanisms are coupled because lithium is consumed through SEI formation on newly exposed crack surfaces. The growth of crack surface area is modeled as a fatigue phenomenon due to the cyclic stresses generated by repeated lithium insertion and de-insertion of graphite particles. This coupled chemical-mechanical degradation model is consistent with the observed capacity loss features for the NCM + LMO/graphite cells.

  7. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    Science.gov (United States)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  8. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  9. The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry

    Directory of Open Access Journals (Sweden)

    Fabrizio Zeri

    2016-07-01

    Conclusions: Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

  10. Validation of a Brief Questionnaire Measuring Positive Mindset in Patients With Uveitis

    Directory of Open Access Journals (Sweden)

    John A. Barry

    2014-03-01

    Full Text Available AimIllness may impact the positivity of a person’s mindset. However, patients with visual impairment, such as uveitis, may struggle to complete questionnaires. The aim of this study was to validate a brief and simple measure of positive mindset in people with uveitis.MethodThis study was a cross-sectional survey of 200 people with uveitis. The Positive Mindset Index (PMI questionnaire uses six items to measure a patient’s happiness, confidence, sense of being in control, stability, motivation, and optimism. ResultsExploratory factor analysis revealed a well-fitting unidimensional factor structure (KMO = .898, with strong factor loadings (from .616 to .721 and excellent internal reliability (Cronbach’s α = .926. The PMI showed strong concurrent validity with the mental health subscale of the SF-36 (r = .789 and good construct validity relative to the physical health subscale of the SF-36 (r = .468. Excellent test-retest reliability was seen (r = .806. Patients taking 10 mg or more corticosteroid daily had significantly lower PMI scores than those on a lower dose or no dose (t (170 = 2.298, p < .023.ConclusionThe PMI has good face validity and sound psychometric properties. It is a very brief and simple measure, thus user-friendly for patients with visual impairment, as well as researchers and others using the scale.

  11. Continuous positive airway pressure and conventional mechanical ventilation in the treatment of meconium aspiration syndrome.

    Science.gov (United States)

    Goldsmith, J P

    2008-12-01

    Meconium aspiration syndrome (MAS) is a complex syndrome that ranges in severity from mild respiratory distress to severe respiratory failure, persistent pulmonary hypertension of the newborn and sometimes death. Understanding of the syndrome's complicated pathophysiology will help determine the appropriate treatment strategy, including the use of continuous positive airway pressure (CPAP), conventional mechanical ventilation (CMV) and other therapies. Approximately 30 to 50% of infants diagnosed with MAS will require CPAP or mechanical ventilation. The optimum modes of ventilation for MAS are not known. Very few studies have been conducted to determine 'best' ventilatory strategies. Despite the introduction, over the last two decades, of innovative ventilatory treatments for this disease (for example, surfactant, high-frequency ventilation, inhaled nitric oxide, extracorporeal membrane oxygenation), the majority of infants can be successfully managed with CPAP or mechanical ventilation alone.

  12. A method for measuring plasma position in TJ-I Tokamak

    International Nuclear Information System (INIS)

    Quin, J.; TJ-I, Team

    1993-01-01

    A method using pairs of Mirnov coils to measure the plasma position in TJ-I is presented. The simple toroidal filament model which neglects the effect of plasma current density profile has proven to be acceptable within the experimental accuracy. The effect of plasma current density profile remains to be small, if the plasma current density profile has a quadratic form. (Author) 5 refs

  13. A method for measuring plasma position in TJ-I Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Quin, J.; TJ-I, Team

    1993-07-01

    A method using pairs of Mirnov coils to measure the plasma position in TJ-I is presented. The simple toroidal filament model which neglects the effect of plasma current density profile has proven to be acceptable within the experimental accuracy. The effect of plasma current density profile remains to be small, if the plasma current density profile has a quadratic form. (Author) 5 refs.

  14. Calibration of an advanced photon source linac beam position monitor used for positron position measurement of a beam containing both positrons and electrons

    International Nuclear Information System (INIS)

    Sereno, Nicholas S.

    1998-01-01

    The Advanced Photon Source (APS) linac beam position monitors can be used to monitor the position of a beam containing both positrons and electrons. To accomplish this task, both the signal at the bunching frequency of 2856 MHz and the signal at 2x2856 MHz are acquired and processed for each stripline. The positron beam position is obtained by forming a linear combination of both 2856 and 5712 MHz signals for each stripline and then performing the standard difference over sum computation. The required linear combination of the 2856 and 5712 MHz signals depends on the electrical calibration of each stripline/cable combination. In this paper, the calibration constants for both 2856 MHz and 5712 MHz signals for each stripline are determined using a pure beam of electrons. The calibration constants are obtained by measuring the 2856 and 5712 MHz stripline signals at various electron beam currents and positions. Finally, the calibration constants measured using electrons are used to determine positron beam position for the mixed beam case

  15. Visible imaging measurement of position and displacement of the last closed flux surface in EAST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y.F. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Xu, G.S., E-mail: gsxu@ipp.ac.cn [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, Y.L.; Yang, J.H.; Yan, N.; Liu, L.; Yuan, S.; Luo, Z.P. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Sang, C.F. [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China); Gu, S.; Xu, J.C.; Hu, G.H.; Wang, Y.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Peng, Y.K.M.; Wan, B.N. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2017-06-15

    Highlights: • A new method for measuring the position and displacement of the LCFS has been developed in EAST tokamak. • This method is based on the visible imaging diagnostic and shown to be an effective and convenient approach. • This method can be applied to measure displacements of the LCFS during application of resonant magnetic perturbation fields. - Abstract: A new method for measuring the position and displacement of the last closed flux surface (LCFS) with visible imaging diagnostics has been developed in EAST. By measuring the relative intensity profiles of the green visible Li-II emission in the tangential planes of the optical systems, it is possible to infer the positions of certain points on the LCFS. This emission line is readily available in discharges with Li-coating wall routinely employed to improve the plasma performance. We describe the measuring method, giving results which are compared with those obtained by EFIT, and showing this as an effective and convenient approach to determine the position of the LCFS. This method is further applied to measure the displacements of the LCFS during application of resonant magnetic perturbation fields in the EAST tokamak.

  16. The effect of the spatial positioning of items on the reliability of questionnaires measuring affect

    Directory of Open Access Journals (Sweden)

    Leigh Leo

    2016-08-01

    Full Text Available Orientation: Extant research has shown that the relationship between spatial location and affect may have pervasive effects on evaluation. In particular, experimental findings on embodied cognition indicate that a person is spatially orientated to position what is positive at the top and what is negative at the bottom (vertical spatial orientation, and to a lesser extent, to position what is positive on the left and what is negative on the right (horizontal spatial orientation. It is therefore hypothesised, that when there is congruence between a respondent’s spatial orientation (related to affect and the spatial positioning (layout of a questionnaire, the reliability will be higher than in the case of incongruence. Research purpose: The principal objective of the two studies reported here was to ascertain the extent to which congruence between a respondent’s spatial orientation (related to affect and the layout of the questionnaire (spatial positioning of questionnaire items may impact on the reliability of a questionnaire measuring affect. Motivation for the study: The spatial position of items on a questionnaire measuring affect may indirectly impact on the reliability of the questionnaire. Research approach, design and method: In both studies, a controlled experimental research design was conducted using a sample of university students (n = 1825. Major findings: In both experiments, evidence was found to support the hypothesis that greater congruence between a respondent’s spatial orientation (related to affect and the spatial positioning (layout of a questionnaire leads to higher reliability on a questionnaire measuring affect. Practical implications: These findings may serve to create awareness of the influence of the spatial positioning of items as a confounding variable in questionnaire design. Contribution/value-add: Overall, this research complements previous studies by confirming the metaphorical representation of affect and

  17. A mechanical design for positioning of gm detector for system of avian flu virus detection equipment

    International Nuclear Information System (INIS)

    Rahmat; Budi Santoso; Krismawan; Abdul Jalil

    2010-01-01

    Mechanical design for positioning of GM detector system has been done. It is used for avian flu detection equipment. The requirements for the design are to protect detection system against shock, portable, and easy to maintain. The mechanical system consists of connectors, cable assemblies, holders, casing, housing and detectors cover. The selected material should have small gamma radiation absorption property in order to give optimum counts for the detector. The design result should give a system that is easy to operate, cheap and easy to assemble. (author)

  18. A Pseudorange Measurement Scheme Based on Snapshot for Base Station Positioning Receivers.

    Science.gov (United States)

    Mo, Jun; Deng, Zhongliang; Jia, Buyun; Bian, Xinmei

    2017-12-01

    Digital multimedia broadcasting signal is promised to be a wireless positioning signal. This paper mainly studies a multimedia broadcasting technology, named China mobile multimedia broadcasting (CMMB), in the context of positioning. Theoretical and practical analysis on the CMMB signal suggests that the existing CMMB signal does not have the meter positioning capability. So, the CMMB system has been modified to achieve meter positioning capability by multiplexing the CMMB signal and pseudo codes in the same frequency band. The time difference of arrival (TDOA) estimation method is used in base station positioning receivers. Due to the influence of a complex fading channel and the limited bandwidth of receivers, the regular tracking method based on pseudo code ranging is difficult to provide continuous and accurate TDOA estimations. A pseudorange measurement scheme based on snapshot is proposed to solve the problem. This algorithm extracts the TDOA estimation from the stored signal fragments, and utilizes the Taylor expansion of the autocorrelation function to improve the TDOA estimation accuracy. Monte Carlo simulations and real data tests show that the proposed algorithm can significantly reduce the TDOA estimation error for base station positioning receivers, and then the modified CMMB system achieves meter positioning accuracy.

  19. Measuring Clearance Mechanics Based on Dynamic Leg Length

    Science.gov (United States)

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  20. A Precision-Positioning Method for a High-Acceleration Low-Load Mechanism Based on Optimal Spatial and Temporal Distribution of Inertial Energy

    Directory of Open Access Journals (Sweden)

    Xin Chen

    2015-09-01

    Full Text Available High-speed and precision positioning are fundamental requirements for high-acceleration low-load mechanisms in integrated circuit (IC packaging equipment. In this paper, we derive the transient nonlinear dynamicresponse equations of high-acceleration mechanisms, which reveal that stiffness, frequency, damping, and driving frequency are the primary factors. Therefore, we propose a new structural optimization and velocity-planning method for the precision positioning of a high-acceleration mechanism based on optimal spatial and temporal distribution of inertial energy. For structural optimization, we first reviewed the commonly flexible multibody dynamic optimization using equivalent static loads method (ESLM, and then we selected the modified ESLM for optimal spatial distribution of inertial energy; hence, not only the stiffness but also the inertia and frequency of the real modal shapes are considered. For velocity planning, we developed a new velocity-planning method based on nonlinear dynamic-response optimization with varying motion conditions. Our method was verified on a high-acceleration die bonder. The amplitude of residual vibration could be decreased by more than 20% via structural optimization and the positioning time could be reduced by more than 40% via asymmetric variable velocity planning. This method provides an effective theoretical support for the precision positioning of high-acceleration low-load mechanisms.

  1. Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports.

    Science.gov (United States)

    Hoppe, Matthias W; Baumgart, Christian; Polglaze, Ted; Freiwald, Jürgen

    2018-01-01

    This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6-8.0%; CV: 1.1-5.1%) and sprint mechanical properties (TEE: 4.5-14.3%; CV: 3.1-7.5%) than the 10 Hz GPS (TEE: 3.0-12.9%; CV: 2.5-13.0% and TEE: 4.1-23.1%; CV: 3.3-20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0-6.0%; CV: 0.7-5.0% and TEE: 2.1-9.2%; CV: 1.6-7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that

  2. Accuracy of Positioning Autonomous Biomimetic Underwater Vehicle Using Additional Measurement of Distances

    Directory of Open Access Journals (Sweden)

    Naus Krzysztof

    2016-12-01

    Full Text Available The article describes a study of problem of estimating the position coordinates of Autonomous Biomimetic Underwater Vehicle (ABUV using two methods: dead reckoning (DR and extended Kalman filter (EKF. In the first part of the paper, navigation system of ABUV is described and scientific problem with underwater positioning is formulated. The main part describes a way of estimating the position coordinates using DR and EKF and a numerical experiment involving motion of ABUV along the predetermined test distance. The final part of the paper contains a comparative statistical analysis of the results, carried out for assessing the accuracy of estimation of the position coordinates using DR and EKF methods. It presents the generalized conclusions from the research and the problems relating to the proper placement of the components of the system measuring distances.

  3. Positive prenatal well-being: conceptualising and measuring mindfulness and gratitude in pregnancy.

    Science.gov (United States)

    O' Leary, Karen; Dockray, Samantha; Hammond, Sean

    2016-08-01

    Little research has examined the usefulness of positive well-being factors during pregnancy. Recent mindfulness research demonstrates that inconsistencies and the suitability of extant measures have yet to be examined in pregnancy. Effects of gratitude during pregnancy have yet to be examined despite consistently reported benefits in non-pregnant groups. The aims of this paper were to develop the Gratitude during Pregnancy (GDP) scale, validate the Mindfulness Awareness Attention Scale (MAAS) and examine the importance of gratitude and mindfulness during pregnancy. In study 1, 375 pregnant women completed gratitude and mindfulness measures. The one-factor structure of the MAAS was retained and demonstrated good reliability α = 0.88. Using exploratory factor analysis, an 18-item GDP scale was developed, demonstrating good reliability α = 0.89. The four GDP factors are as follows: general gratitude, physical changes, antenatal care and social support. In study 2, 87 pregnant women completed well-being questionnaires, including the GDP and MAAS. Gratitude correlated with positive affect, life satisfaction and pregnancy uplifts (p gratitude and provide a reliable means to measure both constructs during pregnancy.

  4. Measuring Positive and Negative Occupational States (PNOSI: Structural Confirmation of a New Belgian Tool

    Directory of Open Access Journals (Sweden)

    Marie Barbier

    2010-12-01

    Full Text Available This article reports on the validation of the Positive and Negative Occupational States Inventory (PNOSI, a new tool for measuring positive and negative occupational states. Three goals were defined: testing the structural validity of the PNOSI, testing its stability, and testing its convergent and discriminant validity with engagement, burnout, commitment, and workaholism. Data were collected in seven different companies (more than 16,000 participants. The factorial validity of the PNOSI was demonstrated using covariance structure analyses. A two-factor model with a negative occupational state factor and a positive occupational state factor fitted the data better than an alternative one-factor model. The two corresponding scales demonstrated good internal consistency. The results confirmed that positive and negative occupational states are distinct constructs and should be measured with different items. Convergent and discriminant validity with related constructs, namely engagement, burnout, commitment, and workaholism, were also demonstrated. The conclusion is that the PNOSI has good psychometric properties.

  5. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    Science.gov (United States)

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  6. Supplementary Material for: Measurements of Positively Charged Ions in Premixed Methane-Oxygen Atmospheric Flames

    KAUST Repository

    Alquaity, Awad B. S.

    2017-01-01

    Cations and anions are formed as a result of chemi-ionization processes in combustion systems. Electric fields can be applied to reduce emissions and improve combustion efficiency by active control of the combustion process. Detailed flame ion chemistry models are needed to understand and predict the effect of external electric fields on combustion plasmas. In this work, a molecular beam mass spectrometer (MBMS) is utilized to measure ion concentration profiles in premixed methane–oxygen argon burner-stabilized atmospheric flames. Lean and stoichiometric flames are considered to assess the dependence of ion chemistry on flame stoichiometry. Relative ion concentration profiles are compared with numerical simulations using various temperature profiles, and good qualitative agreement was observed for the stoichiometric flame. However, for the lean flame, numerical simulations misrepresent the spatial distribution of selected ions greatly. Three modifications are suggested to enhance the ion mechanism and improve the agreement between experiments and simulations. The first two modifications comprise the addition of anion detachment reactions to increase anion recombination at low temperatures. The third modification involves restoring a detachment reaction to its original irreversible form. To our knowledge, this work presents the first detailed measurements of cations and flame temperature in canonical methane–oxygen-argon atmospheric flat flames. The positive ion profiles reported here may be useful to validate and improve ion chemistry models for methane-oxygen flames.

  7. Real-time positioning technology in horizontal directional drilling based on magnetic gradient tensor measurement

    Science.gov (United States)

    Deng, Guoqing; Yao, Aiguo

    2017-04-01

    Horizontal directional drilling (HDD) technology has been widely used in Civil Engineering. The dynamic position of the drill bit during construction is one of significant facts determining the accuracy of the trajectory of HDD. A new method now has been proposed to detecting the position of drill bit by measuring the magnetic gradient tensor of the ground solenoid magnetic beacon. Compared with traditional HDD positioning technologies, this new model is much easier to apply with lower request for construction sites and higher positioning efficiency. A direct current (DC) solenoid as a magnetic dipole is placed on ground near the drill bit, and related sensors array which contains four Micro-electromechanical Systems (MEMS ) tri-axial magnetometers, one MEMS tri-axial accelerometer and one MEMS tri-axial gyroscope is set up for measuring the magnetic gradient tensor of the magnetic dipole. The related HDD positioning model has been established and simulation experiments have been carried out to verify the feasibility and reliability of the proposed method. The experiments show that this method has good positioning accuracy in horizontal and vertical direction, and totally avoid the impact of the environmental magnetic field. It can be found that the posture of the magnetic beacon will impact the remote positioning precision within valid positioning range, and the positioning accuracy is higher with longer baseline for limited space in drilling tools. The results prove that the relative error can be limited in 2% by adjusting position of the magnetic beacon, the layers of the enameled coil, the sensitive of magnetometers and the baseline distance. Conclusion can be made that this new method can be applied in HDD positioning with better effect and wider application range than traditional method.

  8. A cfr-positive clinical staphylococcal isolate from India with multiple mechanisms of linezolid-resistance

    Directory of Open Access Journals (Sweden)

    Vineeth Rajan

    2014-01-01

    Full Text Available Background & objectives: Linezolid, a member of the oxazolidinone class of antibiotics, has been an effective therapeutic option to treat severe infections caused by multidrug resistant Gram positive bacteria. Emergence of linezolid resistant clinical strains is a serious issue in the healthcare settings worldwide. We report here the molecular characterization of a linezolid resistant clinical isolate of Staphylococcus haemolyticus from India. Methods: The species of the clinical isolate was identified by 16S rRNA gene sequencing. The minimum inhibitory concentrations (MICs of linezolid, clindamycin, chloramphenicol and oxacillin were determined by E-test method. To elucidate the mechanism of linezolid-resistance, presence of cfr gene (chloramphenicol florfenicol resistance and mutations in 23S rRNA and ribosomal proteins (L3, L4 and L22 were investigated. Staphylococcal Cassette Chromosome mec (SCCmec typing was performed by multiplex PCR. Results: The study documented a rare clinical S. haemolyticus strain with three independent mechanisms of linezolid-resistance. The strain carried cfr gene, the only known transmissible mechanism of linezolid-resistance. The strain also possessed resistance-conferring mutations such as G 2576 T in domain V of 23S rRNA gene and Met 156 Thr in L3 ribosomal protein. The other ribosomal proteins (L4 and L22 did not exhibit mutations accountable for linezolid-resistance. Restriction digestion by NheI revealed that all the alleles of 23S rRNA gene were mutated. The isolate showed elevated MIC values (>256 ΅g ml -[1] of linezolid, clindamycin, chloramphenicol and oxacillin. Methicillin resistance was conferred by type I SCCmec element. The strain also harboured lsa(B gene which encodes an ABC transporter that can efflux clindamycin. Interpretation & conclusions: The present study reports the first clinical strain from India with transmissible and multiple mechanisms of linezolid-resistance. Judicious use of

  9. Remote state preparation using positive operator-valued measures

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Siendong, E-mail: sdhuang@mail.ndhu.edu.tw [Department of Applied Mathematics, National Dong Hwa University, Hualien 974, Taiwan (China)

    2013-02-04

    We consider the process of remote state preparation using a pure state |ψ〉 with the maximal Schmidt number n. For any given state σ, pure or mixed, a construction of a positive operator-valued measure {M_j}{sub j=0}{sup n} is provided. The classical outcome j=0 indicates the failure of a remote preparation of σ. All other classical outcomes j>0 correspond to unitary transformations of the receiver system such that σ can be prepared. The total probability of successful remote preparation depends on the state σ. Our protocol is a variation of conclusive teleportation and the classical bits required for this protocol are given by log{sub 2}(n+1), which is nearly half that of conclusive teleportation.

  10. Design and measurement of signal processing system for cavity beam position monitor

    International Nuclear Information System (INIS)

    Wang Baopeng; Leng Yongbin; Yu Luyang; Zhou Weimin; Yuan Renxian; Chen Zhichu

    2013-01-01

    In this paper, in order to achieve the output signal processing of cavity beam position monitor (CBPM), we develop a digital intermediate frequency receiver architecture based signal processing system, which consists of radio frequency (RF) front end and high speed data acquisition board. The beam position resolution in the CBPM signal processing system is superior to 1 μm. Two signal processing algorithms, fast Fourier transform (FFT) and digital down converter (DDC), are evaluated offline using MATLAB platform, and both can be used to achieve, the CW input signal, position resolutions of 0.31 μm and 0.10 μm at -16 dBm. The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement, reaching the position resolution of 0.49 μm due to truncation error. The whole system works well and the performance meets design target. (authors)

  11. Effect of prone positioning during mechanical ventilation on mortality among patients with acute respiratory distress syndrome: a systematic review and meta-analysis.

    Science.gov (United States)

    Sud, Sachin; Friedrich, Jan O; Adhikari, Neill K J; Taccone, Paolo; Mancebo, Jordi; Polli, Federico; Latini, Roberto; Pesenti, Antonio; Curley, Martha A Q; Fernandez, Rafael; Chan, Ming-Cheng; Beuret, Pascal; Voggenreiter, Gregor; Sud, Maneesh; Tognoni, Gianni; Gattinoni, Luciano; Guérin, Claude

    2014-07-08

    Mechanical ventilation in the prone position is used to improve oxygenation and to mitigate the harmful effects of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS). We sought to determine the effect of prone positioning on mortality among patients with ARDS receiving protective lung ventilation. We searched electronic databases and conference proceedings to identify relevant randomized controlled trials (RCTs) published through August 2013. We included RCTs that compared prone and supine positioning during mechanical ventilation in patients with ARDS. We assessed risk of bias and obtained data on all-cause mortality (determined at hospital discharge or, if unavailable, after longest follow-up period). We used random-effects models for the pooled analyses. We identified 11 RCTs (n=2341) that met our inclusion criteria. In the 6 trials (n=1016) that used a protective ventilation strategy with reduced tidal volumes, prone positioning significantly reduced mortality (risk ratio 0.74, 95% confidence interval 0.59-0.95; I2=29%) compared with supine positioning. The mortality benefit remained in several sensitivity analyses. The overall quality of evidence was high. The risk of bias was low in all of the trials except one, which was small. Statistical heterogeneity was low (I2mechanical ventilation improved survival among patients with ARDS who received protective lung ventilation. © 2014 Canadian Medical Association or its licensors.

  12. Mechanical measurements

    CERN Document Server

    Venkateshan, S P

    2015-01-01

    The first edition of this book was co-published by Ane Books India, and CRC Press in 2008. This second edition is an enlarged version of the web course developed by the author at IIT Madras, and also a modified and augmented version of the earlier book.  Major additions/modifications presented are in the treatment of errors in measurement, temperature measurement, measurement of thermo-physical properties, and data manipulation. Many new worked examples have been introduced in this new and updated second edition. 

  13. Passive hybrid force-position control for tele-operation based on real-time simulation of a virtual mechanism

    International Nuclear Information System (INIS)

    Joly, L.; Andriot, C.

    1995-01-01

    Hybrid force-position control aims at controlling position and force in separate directions. It is particularly useful to perform certain robotic tasks. In tele-operation context, passivity is important because it ensures stability when the system interacts with any passive environment. In this paper, we propose an original approach to hybrid force-position control of a force reflecting tele-robot system. It is based on real-time simulation of a virtual mechanism corresponding to the task. the resulting control law is passive. Experiments on a 6 degrees of freedom tele-operation system consisting in following a bent pipe under several control modes validate the approach. (authors). 12 refs., 6 figs

  14. Modal Measurements and Model Corrections of A Large Stroke Compliant Mechanism

    Directory of Open Access Journals (Sweden)

    Wijma W.

    2014-08-01

    Full Text Available In modelling flexure based mechanisms, generally flexures are modelled perfectly aligned and nominal values are assumed for the dimensions. To test the validity of these assumptions for a two Degrees Of Freedom (DOF large stroke compliant mechanism, eigenfrequency and mode shape measurements are compared to results obtained with a flexible multibody model. The mechanism consists of eleven cross flexures and seven interconnecting bodies. From the measurements 30% lower eigenfrequencies are observed than those obtained with the model. With a simplified model, it is demonstrated that these differences can be attributed to wrongly assumed leaf spring thickness and misalignment of the leaf springs in the cross flexures. These manufacturing tolerances thus significantly affect the behaviour of the two DOF mechanism, even though it was designed using the exact constraint design principle. This design principle avoids overconstraints to limit internal stresses due to manufacturing tolerances, yet this paper shows clearly that manufacturing imperfections can still result in significantly different dynamic behaviour.

  15. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Directory of Open Access Journals (Sweden)

    Nickenig Georg

    2009-05-01

    Full Text Available Abstract Background Wrist blood pressure (BP devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP measurement methods: 1 office BP, 2 home BP (Omron wrist device HEM- 637 IT with position sensor, 3 24-hour ambulatory BP(24-h ABPM (ABPM-04, Meditech, Hunconventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have to be used cautious and with defined limitations, the use of validated devices with position sensor according to recently recommended measurement schedules might have the potential to be used for therapy monitoring.

  16. The Mechanisms of Virulence Regulation by Small Noncoding RNAs in Low GC Gram-Positive Pathogens

    Directory of Open Access Journals (Sweden)

    Stephanie Pitman

    2015-12-01

    Full Text Available The discovery of small noncoding regulatory RNAs (sRNAs in bacteria has grown tremendously recently, giving new insights into gene regulation. The implementation of computational analysis and RNA sequencing has provided new tools to discover and analyze potential sRNAs. Small regulatory RNAs that act by base-pairing to target mRNAs have been found to be ubiquitous and are the most abundant class of post-transcriptional regulators in bacteria. The majority of sRNA studies has been limited to E. coli and other gram-negative bacteria. However, examples of sRNAs in gram-positive bacteria are still plentiful although the detailed gene regulation mechanisms behind them are not as well understood. Strict virulence control is critical for a pathogen’s survival and many sRNAs have been found to be involved in that process. This review outlines the targets and currently known mechanisms of trans-acting sRNAs involved in virulence regulation in various gram-positive pathogens. In addition, their shared characteristics such as CU interaction motifs, the role of Hfq, and involvement in two-component regulators, riboswitches, quorum sensing, or toxin/antitoxin systems are described.

  17. Position-dependent friction in quantum mechanics

    International Nuclear Information System (INIS)

    Srokowski, T.

    1985-01-01

    The quantum description of motion of a particle subjected to position-dependent frictional forces is presented. The two cases are taken into account: a motion without external forces and in the harmonic oscillator field. As an example, a frictional barrier penetration is considered. 16 refs. (author)

  18. Teleoperation environment based on virtual reality. Application of two-planes method for position measurement

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Tezuka, Tetsuo; Inoue, Ryuji

    1998-01-01

    A teleoperation system based on virtual environment (VE) is an emergent technology for operating a robot in remote or hazardous environment. We have developed a VE-based teleoperation system for robot-arm manipulation in a simplified real world. The VE for manipulating the robot arm is constructed by measuring the 3D positions of the objects around the robot arm by motion-stereo method. The 3D position is estimated by using two-(calibration) planes method based on images captured by the CCD camera on the robot-arm, since the two-planes method does not need pin-hole-model assumption to the camera system. The precision of this 3D-measurement is evaluated through experiments and then derived is the theoretical model to the error in the measurement. This measurement system is applied to VE-based teleoperation experiment for Peg-in-hole practice by the robot arm. (author)

  19. Two-qubit Bell inequality for which positive operator-valued measurements are relevant

    International Nuclear Information System (INIS)

    Vertesi, T.; Bene, E.

    2010-01-01

    A bipartite Bell inequality is derived which is maximally violated on the two-qubit state space if measurements describable by positive operator valued measure (POVM) elements are allowed, rather than restricting the possible measurements to projective ones. In particular, the presented Bell inequality requires POVMs in order to be maximally violated by a maximally entangled two-qubit state. This answers a question raised by N. Gisin [in Quantum Reality, Relativistic Causality, and Closing the Epistemic Circle: Essays in Honour of Abner Shimony, edited by W. C. Myrvold and J. Christian (Springer, The Netherlands, 2009), pp. 125-138].

  20. Opto-mechanical design of small infrared cloud measuring device

    Science.gov (United States)

    Zhang, Jiao; Yu, Xun; Tao, Yu; Jiang, Xu

    2018-01-01

    In order to make small infrared cloud measuring device can be well in a wide temperature range and day-night environment, a design idea using catadioptric infrared panoramic imaging optical system and simple mechanical structure for realizing observation clode under all-weather conditions was proposed. Firstly, the optical system of cloud measuring device was designed. An easy-to-use numerical method was proposed to acquire the profile of a catadioptric mirror, which brought the property of equidistance projection and played the most important role in a catadioptric panoramic lens. Secondly, the mechanical structure was studied in detail. Overcoming the limitations of traditional primary mirror support structure, integrative design was used for refractor and mirror support structure. Lastly, temperature adaptability and modes of the mirror support structure were analyzed. Results show that the observation range of the cloud measuring device is wide and the structure is simple, the fundamental frequency of the structure is greater than 100 Hz, the surface precision of the system reflector reaches PV of λ/10 and RMS of λ/40under the load of temperature range - 40 60°C, it can meet the needs of existing meteorological observation.

  1. Position and width of normal adult optic chiasm as measured in coronal MRI

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Park, Jin Sook

    1994-01-01

    To evaluate the position and transverse dimension of the adult optic chiasm in normal Korean adult. The authors analysed 3D coronal volume images (TR/TE=30/13, flip angle=30 .deg. ) of 136 normal adult subjects without known visual abnormality. All MRI examinations were performed using a 0.5T system. MRI was reviewed retrospectively to determine the position (horizontal and tilted) of the potic chiosm and the transverse dimension of the optic chiasm was measured. Seventy- five (55%) of the 136 normal subjects had horizontal position, and sixty-one (45%) had tilted position. Thirty- eight (62%) of 61 with tilted position showed higher position on the right side, and twenty-three (38%) showed higher position on the side. The average transverse dimension(mean SD) was 15.2 ± 0.7mm in men and 14.6 ± 1.0mm in women. The difference of transverse dimension between men and women was statistically significant. Tilted position of the adult optic chiasm on coronal MRI was seen in approximately half of normal adults. The average of transverse dimension of normal optic chiasm was 15mm

  2. A novel method to measure skin mechanical properties with three-dimensional digital image correlation.

    Science.gov (United States)

    Xu, Z; Dela Cruz, J; Fthenakis, C; Saliou, C

    2018-06-06

    Measuring skin mechanical properties has been of great interest in the skincare industry. It is a high accuracy and non-invasive optical technique which quantitatively tracks skin movement and deformation under mechanical perturbations. A study was conducted with female subjects (25-65 years old). A refined speckle pattern applied onto the skin surface was used for DIC measurements. A unidirectional force pulled the skin at a constant velocity, while the deformation process was quantified by the DIC. Prior to the DIC measurement, Cutometer ® readings were taken on the same area. The DIC protocol's reproducibility across multiple pattern applications, the measurement's repeatability, and the sensitivity in differentiating skin mechanical properties were investigated. Subjects were clustered with statistical significance according to their skin mechanical properties described by six DIC metrics (μ [major strain], σ [major strain], μ [minor strain], σ [minor strain], μ [displacement], and σ [displacement]). Most measurement random errors are below 6%. This is several folds smaller in magnitude than the difference in the mean response between the clusters. Several Cutometer ® parameters also showed good agreement with μ (displacement). DIC was able to differentiate skins of different mechanical qualities. We also proposed the physical significance of the DIC metrics. Some of the DIC metrics potentially offer new insights into skin mechanical properties that complement those revealed by conventional instruments. Accurate measurements, large measurement areas along with ease of direct visualization are substantial advantages of DIC. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Secure positioning in wireless networks

    DEFF Research Database (Denmark)

    Capkun, Srdjan; Hubaux, Jean-Pierre

    2006-01-01

    So far, the problem of positioning in wireless networks has been studied mainly in a non-adversarial settings. In this work, we analyze the resistance of positioning techniques to position and distance spoofing attacks. We propose a mechanism for secure positioning of wireless devices, that we call...... Verifiable Multilateration. We then show how this mechanism can be used to secure positioning in sensor networks. We analyze our system through simulations....

  4. Lung recruitment during mechanical positive pressure ventilation in the PICU: what can be learned from the literature?

    NARCIS (Netherlands)

    Halbertsma, F.J.; Hoeven, J.G. van der

    2005-01-01

    A literature review was conducted to assess the evidence for recruitment manoeuvres used in conventional mechanical positive pressure ventilation. A total of 61 studies on recruitment manoeuvres were identified: 13 experimental, 31 ICU, 6 PICU and 12 anaesthesia studies. Recruitment appears to be a

  5. Positive effect of Chang Run Tong on colonic remodeling in streptozotocin-induced diabetic rats and mechanisms involved

    DEFF Research Database (Denmark)

    Zhao, Jingbo; Sha, Hong; Gregersen, Hans

    2015-01-01

    Objective: It has been documented that the Chinese medicine Chang Run Tong (CRT) has a positive effect on constipation which is a prominent symptom in diabetic patients. This present study investigated the effect and the possible mechanism of CRT on colonic remodeling in streptozotocin (STZ...

  6. An education model of a nano-positioning system for mechanical engineers

    International Nuclear Information System (INIS)

    Lee, Dong Yeon; Gweon, Dae Gab

    2006-01-01

    The increasing use of nano-positioners in a wide variety of laboratory and industrial applications has created a need for nano-mechatronics education in all engineering disciplines. The subject of nano-mechatronics is broad and interdisciplinary. This article focuses on the way nano-mechatronics is taught in department of mechanical engineering at Korea Advanced Institute of Science and Technology (KAIST). As one model of nano-positioning systems, design and experimental methodology is presented in this article. For design phase, the stiffness and resonant frequencies are found analytically and verified by using a commercial finite element analysis program. Next, for experimental phase, various tests are performed to access the performances of the designed nano-positioner, for example, sine-tracking, multi-step response and travel-range check etc. Finally, the definition of 'separation frequency' is described and some comments are discussed

  7. Measuring the Amount of Mechanical Vibration During Lathe Processing

    Directory of Open Access Journals (Sweden)

    Štefánia SALOKYOVÁ

    2015-06-01

    Full Text Available The article provides basic information regarding the measurement and evaluation of mechanical vibration during the processing of material by lathe work. The lathe processing can be characterized as removing material by precisely defined tools. The results of the experimental part are values of the vibration acceleration amplitude measured by the piezoelectric sensor on the bearing house of the lathe. A set of new knowledge and conclusions is formulated based on the analysis of the created graphical dependencies.

  8. Periodic position dependence of the energy measured in the CMS electromagnetic calorimeter

    CERN Document Server

    Descamps, Julien

    2006-01-01

    A uniform energy measurement response of the CMS electromagnetic calorimeter ECAL is essential for precision physics at the LHC. The ECAL barrel calorimeter consists of 61200 lead tungstate crystals arranged in a quasi-projective geometry. The energy of photons reaching the ECAL will be reconstructed by summing the channels corresponding to matrices of 3x3 or 5x5 crystals centred on the crystal with the largest energy deposit. The energy measured using such matrices of fixed size has been studied using electron test beam data taken in 2004. The variation of the energy containment with the incident electron impact position on the central crystal leads to a degradation of the energy resolution. A method using only the calorimeter information is presented to correct for the position dependent response. After correction, the energy resolution performance for uniform impact distributions of the electrons on the front face of a crystal approaches that obtained for maximal containment with a central impact. The univ...

  9. Vector electric field measurement via position-modulated Kelvin probe force microscopy

    Science.gov (United States)

    Dwyer, Ryan P.; Smieska, Louisa M.; Tirmzi, Ali Moeed; Marohn, John A.

    2017-10-01

    High-quality spatially resolved measurements of electric fields are critical to understanding charge injection, charge transport, and charge trapping in semiconducting materials. Here, we report a variation of frequency-modulated Kelvin probe force microscopy that enables spatially resolved measurements of the electric field. We measure electric field components along multiple directions simultaneously by employing position modulation and lock-in detection in addition to numeric differentiation of the surface potential. We demonstrate the technique by recording linescans of the in-plane electric field vector in the vicinity of a patch of trapped charge in a 2,7-diphenyl[1]benzothieno[3,2-b][1]benzothiophene (DPh-BTBT) organic field-effect transistor. This technique is simple to implement and should be especially useful for studying electric fields in spatially inhomogeneous samples like organic transistors and photovoltaic blends.

  10. Nonlocality in Bohmian mechanics

    Science.gov (United States)

    Ghafar, Zati Amalina binti Mohd Abdul; Radiman, Shahidan bin; Siong, Ch'ng Han

    2018-04-01

    The Einstein-Podolsky-Rosen (EPR) paradox demonstrates that entangled particles can interact in such a way that it is possible to measure both their position and momentum instantaneously. The position or momentum of one particle can be determined by measuring another identical particle that exists in another space. This instantaneous action is actually called nonlocality. The nonlocality has been proved by Bell's theorem that states that all quantum theories must be nonlocal. The Bell's theorem gives a strong support to the hidden variable theory, i.e. Bohmian mechanics. Using nonlocality, we present that the velocity field of one particle can be obtained by measuring the velocity of other particles. The trajectory of these particles is perhaps surrealistic trajectory due to the nonlocality.

  11. Application of Digital Image Correlation to Measurement of Packaging Material Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Jian-Wei Zhou

    2013-01-01

    Full Text Available Among various packaging materials, papers and polymer plastics are the most common due to their light weights, low costs, and other advantages. However, their mechanical properties are difficult to measure precisely because of their softness. To overcome the difficulty, a new measure instrument prototype is proposed based on an optical method known as the digital image correlation (DIC. Experiments are designed to apply the DIC to measure mechanical properties of flexible packaging materials, including the stress-strain relationship, the Poisson ratio, the coefficient of heat expansion, the creep deformation, and the top-pressure deformation of corrugated box. In addition, the low frequency vibration of package is simulated, and the vibration frequencies are measured by DIC. Results obtained in the experiments illustrate the advantages of the DIC over traditional methods: noncontact, no reinforced effect, high precision over entire area, wide measurement range, and good measurement stability.

  12. A method for automated processing of measurement information during mechanical drilling

    Energy Technology Data Exchange (ETDEWEB)

    Samonenko, V.I.; Belinkov, V.G.; Romanova, L.A.

    1984-01-01

    An algorithm is cited for a developed method for automated processing of measurement information during mechanical drilling. Its use in conditions of operation of an automated control system (ASU) from drilling will make it possible to precisely identify a change in the lithology, the physical and mechanical and the abrasive properties, in the stratum (pore) pressure in the rock being drilled out during mechanical drilling, which along with other methods for testing the drilling process will increase the reliability of the decisions made.

  13. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    International Nuclear Information System (INIS)

    Lerche, Ch.W.; Ros, A.; Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A.; Sanchez, F.; Benlloch, J.M.

    2009-01-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  14. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lerche, Ch.W. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain)], E-mail: lerche@ific.uv.es; Ros, A. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain); Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain); Sanchez, F.; Benlloch, J.M. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain)

    2009-06-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  15. Measuring the Mechanical Properties of Plant Cell Walls

    Directory of Open Access Journals (Sweden)

    Hannes Vogler

    2015-03-01

    Full Text Available The size, shape and stability of a plant depend on the flexibility and integrity of its cell walls, which, at the same time, need to allow cell expansion for growth, while maintaining mechanical stability. Biomechanical studies largely vanished from the focus of plant science with the rapid progress of genetics and molecular biology since the mid-twentieth century. However, the development of more sensitive measurement tools renewed the interest in plant biomechanics in recent years, not only to understand the fundamental concepts of growth and morphogenesis, but also with regard to economically important areas in agriculture, forestry and the paper industry. Recent advances have clearly demonstrated that mechanical forces play a crucial role in cell and organ morphogenesis, which ultimately define plant morphology. In this article, we will briefly review the available methods to determine the mechanical properties of cell walls, such as atomic force microscopy (AFM and microindentation assays, and discuss their advantages and disadvantages. But we will focus on a novel methodological approach, called cellular force microscopy (CFM, and its automated successor, real-time CFM (RT-CFM.

  16. Charge dividing mechanism in position-sensitive detectors

    International Nuclear Information System (INIS)

    Radeka, V.; Rehak, P.

    1978-01-01

    A complete charge-division mechanism, including both the diffusion and the electromagnetic wave propagation on resistive electrodes, is presented. The charge injected into such a transmission line divides between the two ends according to the ratio of resistances and independently of the value of the line resistance, of the propagation mechanism and of the distribution of inductance and capacitance along the line. The shortest charge division time is achieved for Rl = 2π (L/C)/sup 1/2), where R, L, C are resistance, inductance and capacitance per unit length and l is the length of the line

  17. Full-field measurements and identification in solid mechanics

    CERN Document Server

    Grediac, Michel

    2008-01-01

    This timely book presents cutting-edge developments by experts in the field on the rapidly developing and scientifically challenging area of full-field measurement techniques used in solid mechanics - including photoelasticity, grid methods, deflectometry, holography, speckle interferometry and digital image correlation. The evaluation of strains and the use of the measurements in subsequent parameter identification techniques to determine material properties are also presented. Since parametric identification techniques require a close coupling of theoretical models and experimental measurements, the book focuses on specific modeling approaches that include finite element model updating, the equilibrium gap method, constitutive equation gap method, virtual field method and reciprocity gap method. In the latter part of the book, the authors discuss two particular applications of selected methods that are of special interest to many investigators: the analysis of localized phenomenon and connections between mi...

  18. Study of position resolution for cathode readout MWPC with measurement of induced charge distribution

    International Nuclear Information System (INIS)

    Chiba, J.; Iwasaki, H.; Kageyama, T.; Kuribayashi, S.; Nakamura, K.; Sumiyoshi, T.; Takeda, T.

    1983-01-01

    A readout technqiue of multiwire proportional chambers by measurement of charges induced on cathode strips, orthogonal to anode wires, requires an algorithm to relate the measured charge distribution to the avalanche position. With given chamber parameters and under the influence of noise, resolution limits depend on the chosen algorithm. We have studied the position resolution obtained by the centroid method and by the charge-ratio method, both using three consecutive cathode strips. While the centroid method uses a single number, the center of gravity of the measured charges, the charge-ratio method uses the ratios of the charges Qsub(i-1)/Qsub(i) and Qsub(i+1)/Qsub(i) where Qsub(i) is the largest. To obtain a given resolution, the charge-ratio method generally allows wider cathode strips and therefore a smaller number of readout channels than the centroid method. (orig.)

  19. Real-time measurement of relative sensor position changes using ultrasonic signal evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebova, O.; Bulavinov, A.; Kroening, M. [Fraunhofer Institute Nondestructive Testing IZFP, Saarbruecken (Germany)

    2008-07-01

    Ultrasonic testing is considered to be one of the most commonly applied nondestructive testing techniques for flaw detection and material characterization. Traditional Nondestructive Testing (NDT) provides detection of material discontinuities that may cause failure within the designed lifetime of a part or component. In addition, Quantitative Nondestructive Testing (QNDT) provides means to obtain required information about type, size and location of deficiencies to the integrity of the inspected structure and further use under specific, given load conditions. The ''Acoustic Mouse'' technique has been developed as a tool for manual ultrasonic inspection to provide test results that can be evaluated quantitatively. The ultrasonic data are processed by real-time variation methods to extract position information from backscattered acoustic noise and geometric scatter signals in the inspection volume. The position and positional changes of the ''Acoustic Mouse'' sensor (transducer) are determined by the sequential analysis of ultrasonic data (highresolution sector-scans), which are acquired and reconstructed using the Sampling Phased Array technique. The results of first experiments conducted with linear scanning and intentional lift-offs demonstrate sufficient accuracy in position measurements. (orig.)

  20. Acoustic emission measurements in petroleum-related rock mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Unander, Tor Erling

    2002-07-01

    Acoustic emission activity in rock has usually been studied in crystalline rock, which reflects that rock mechanics has also mostly been occupied with such rocks in relations to seismology, mining and tunneling. On the other hand, petroleum-related rock mechanics focuses on the behaviour of sedimentary rock. Thus, this thesis presents a general study of acoustic emission activity in sedimentary rock, primarily in sandstone. Chalk, limestone and shale have also been tested, but to much less degree because the AE activity in these materials is low. To simplify the study, pore fluids have not been used. The advent of the personal computer and computerized measuring equipment have made possible new methods both for measuring and analysing acoustic emissions. Consequently, a majority of this work is devoted to the development and implementation of new analysis techniques. A broad range of topics are treated: (1) Quantification of the AE activity level, assuming that the event rate best represents the activity. An algorithm for estimating the event rate and a methodology for objectively describing special changes in the activity e.g., onset determination, are presented. (2) Analysis of AE waveform data. A new method for determining the source energy of an AE event is presented, and it is shown how seismic source theory can be used to analyze even intermediate quality data. Based on these techniques, it is shown that a major part of the measured AE activity originates from a region close to the sensor, not necessarily representing the entire sample. (3) An improved procedure for estimating source locations is presented. The main benefit is a procedure that better handles arrival time data with large errors. Statistical simulations are used to quantify the uncertainties in the locations. The analysis techniques are developed with the application to sedimentary rock in mind, and in two articles, the techniques are used in the study of such materials. The work in the first

  1. Development of a rotary clap mechanism for positive-displacement rotary pumps: Kinematic analysis and working principle

    International Nuclear Information System (INIS)

    Shim, Sung Bo; Kim, Kyeong Uk; Park, Young Jun; Kim, Jong Mun

    2015-01-01

    A five-bar spatial mechanism named as a rotary clap mechanism is developed as a pumping device for positive displacement rotary pumps. The mechanism comprises a driving crank, a shaft link with two pins and two gears mounted on the middle and both ends, two rotors with jaws equally spaced along their circumferences, and two fixed internal gears. As the crank rotates, the gear pin-jointed to the crank rotates about the crank pin and at the same time rotates about the center of the fixed internal gears like a hypo-cyclic gear train. The gear-attached shaft link also rotates about the crank pin and about the fixed internal gears at the same time. This motion of the shaft link makes the pins rotate about the center of the fixed internal gears with a periodically varying radius. Therefore, two rotors driven by the pins rotate with different angular velocities. One rotor alternately leads and lags relative to the other rotor. These lead-lag motions between the two jaws of the rotors, which result in suction and discharge required for pumping, resemble hand clapping from which the mechanism was named. Construction and design parameters of the rotary clap mechanism are introduced, and kinematic analysis of this mechanism is performed. The relationships among design parameters, inherent constraints, and effects of design parameters on the is placement of mechanism are also presented.

  2. A fast high-precision six-degree-of-freedom relative position sensor

    Science.gov (United States)

    Hughes, Gary B.; Macasaet, Van P.; Griswold, Janelle; Sison, Claudia A.; Lubin, Philip; Meinhold, Peter; Suen, Jonathan; Brashears, Travis; Zhang, Qicheng; Madajian, Jonathan

    2016-03-01

    Lasers are commonly used in high-precision measurement and profiling systems. Some laser measurement systems are based on interferometry principles, and others are based on active triangulation, depending on requirements of the application. This paper describes an active triangulation laser measurement system for a specific application wherein the relative position of two fixed, rigid mechanical components is to be measured dynamically with high precision in six degrees of freedom (DOF). Potential applications include optical systems with feedback to control for mechanical vibration, such as target acquisition devices with multiple focal planes. The method uses an array of several laser emitters mounted on one component. The lasers are directed at a reflective surface on the second component. The reflective surface consists of a piecewise-planar pattern such as a pyramid, or more generally a curved reflective surface such as a hyperbolic paraboloid. The reflected spots are sensed at 2-dimensional photodiode arrays on the emitter component. Changes in the relative position of the emitter component and reflective surface will shift the location of the reflected spots within photodiode arrays. Relative motion in any degree of freedom produces independent shifts in the reflected spot locations, allowing full six-DOF relative position determination between the two component positions. Response time of the sensor is limited by the read-out rate of the photodiode arrays. Algorithms are given for position determination with limits on uncertainty and sensitivity, based on laser and spot-sensor characteristics, and assuming regular surfaces. Additional uncertainty analysis is achievable for surface irregularities based on calibration data.

  3. An Implementation of Error Minimization Position Estimate in Wireless Inertial Measurement Unit using Modification ZUPT

    Directory of Open Access Journals (Sweden)

    Adytia Darmawan

    2016-12-01

    Full Text Available Position estimation using WIMU (Wireless Inertial Measurement Unit is one of emerging technology in the field of indoor positioning systems. WIMU can detect movement and does not depend on GPS signals. The position is then estimated using a modified ZUPT (Zero Velocity Update method that was using Filter Magnitude Acceleration (FMA, Variance Magnitude Acceleration (VMA and Angular Rate (AR estimation. Performance of this method was justified on a six-legged robot navigation system. Experimental result shows that the combination of VMA-AR gives the best position estimation.

  4. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...... position displays complex behavior with regions of positive and negative interference. By analyzing the scattered light intensity as a function of the axial position of the trapped sphere, we propose a simple method to increase the sensitivity and control the linear range of axial position detection....

  5. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans

    %), with only one study rated as ‘good’. The reliability domain was most often investigated. Fewof the assessment methods in the included studies that had ‘fair’ or ‘good’ measurement properties demonstrated acceptable results for both reliability and validity.ConclusionWe found a substantially larger number......ABSTRACT OARSI Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review Larsen CM1, Juul-Kristensen B1,2 Lund H1,2, Søgaard K11University of Southern Denmark, Institute of Sports Science and Clinical Biomechanics2Institute...... assessment methods have measured the degree of scapular dyskinesis, subjectively by visual evaluation and objectively by measurements of static and dynamic scapular positioning, by either a 3-dimensional electromagnetic device or 2-dimensional clinically applicable methods. Since advanced equipment (i.e. 3D...

  6. Positive Mental Health; measurement, relevance and implications

    NARCIS (Netherlands)

    Lamers, S.M.A.

    2012-01-01

    The professionalization of psychology yielded many advantages, but also led to a main focus on psychopathology in mental health care. This thesis investigated an additional positive approach to mental health, focusing on positive feelings and life satisfaction (emotional well-being) and optimal

  7. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  8. Clinical measuring system for the form and position errors of circular workpieces using optical fiber sensors

    Science.gov (United States)

    Tan, Jiubin; Qiang, Xifu; Ding, Xuemei

    1991-08-01

    Optical sensors have two notable advantages in modern precision measurement. One is that they can be used in nondestructive measurement because the sensors need not touch the surfaces of workpieces in measuring. The other one is that they can strongly resist electromagnetic interferences, vibrations, and noises, so they are suitable to be used in machining sites. But the drift of light intensity and the changing of the reflection coefficient at different measuring positions of a workpiece may have great influence on measured results. To solve the problem, a spectroscopic differential characteristic compensating method is put forward. The method can be used effectively not only in compensating the measuring errors resulted from the drift of light intensity but also in eliminating the influence to measured results caused by the changing of the reflection coefficient. Also, the article analyzes the possibility of and the means of separating data errors of a clinical measuring system for form and position errors of circular workpieces.

  9. Mean values and measures in quantum mechanics and classical mechanics

    International Nuclear Information System (INIS)

    Bass, J.

    1980-01-01

    In quantum mechanics, for a system at a fixed time, the theory of operators associates to every physical quantity X a probability law. But it is not possible to associate a probability law to a pair (X, Y) of operators, when they do not commute. Therefore it is not possible to represent the physical quantities by the usual methods of probability theory. The aim of this paper is to show that, if X, Y are represented by non random functions which are oscillating in such a way that they generate temporal averages their exist pairs of functions X, Y which have properties similar to pairs of operators. To X and to Y it is possible to associate two measures analogous to probability measures, but that is not possible for the pair (X, Y). The functions satisfying to such conditions are the pseudo-random function, a class of stationary functions which is complementary of the class of almost-periodic functions. The construction of these functions makes use of uniformly distributed sequences of real numbers, which constitute a simulation of random variables uniformly distributed over [0, 1]. Their properties are consequences of the ergodic theorems of H. Weyl (1916) and are related to the properties of irrational numbers [fr

  10. A survey regarding acceptability of oral emergency contraception according to the posited mechanism of action.

    Science.gov (United States)

    Willetts, S J; MacDougall, M; Cameron, S T

    2017-08-01

    The objective was to determine the acceptability to women of oral emergency contraception (EC) that works by inhibiting ovulation, preventing implantation or disrupting implantation, and also to determine the characteristics of women associated with the acceptability of each posited mechanism of action. Women completed a self-administered, anonymous questionnaire asking whether they would consider using an EC pill based on each of three hypothetical mechanisms of action: inhibiting ovulation, preventing implantation or disrupting implantation. The questionnaire was distributed among women in Edinburgh, UK, (a) presenting for EC at a community pharmacy, (b) attending a clinic for insertion of intrauterine contraception (IUC) or (c) attending a clinic for an induced abortion. Descriptive analyses stratified women according to healthcare setting and personal characteristics. Univariable and multivariable analyses were used to establish factors which may predict acceptability of each EC pill's mechanism of action. Four hundred and nineteen out of 458 (91%) women responded to the survey. Overall, women reported that EC would be acceptable if it worked by inhibiting ovulation (89%), preventing implantation (83%) or disrupting implantation (75%). Among women seeking abortion, more would accept an EC pill which disrupted implantation compared to women seeking IUC (odds ratio, 2.19; 95% confidence interval, 1.30-3.69; p=.004). Based on multivariable analyses, factors associated with acceptability included previous use of EC, previously holding strong views against abortion and having had a previous abortion. For each of the posited mechanisms of action, a majority of women surveyed would be willing to consider oral EC to prevent unintended pregnancy. The scope of the study was limited, and further work on the views of women in the wider population is needed. This is important as the development of such drugs to prevent pregnancy is likely to raise political and ethical

  11. Measurement of the uniaxial mechanical properties of rat skin using different stress-strain definitions.

    Science.gov (United States)

    Karimi, A; Navidbakhsh, M

    2015-05-01

    The mechanical properties of skin tissue may vary according to the anatomical locations of a body. There are different stress-strain definitions to measure the mechanical properties of skin tissue. However, there is no agreement as to which stress-strain definition should be implemented to measure the mechanical properties of skin at different anatomical locations. Three stress definitions (second Piola-Kichhoff stress, engineering stress, and true stress) and four strain definitions (Almansi-Hamel strain, Green-St. Venant strain, engineering strain, and true strain) are employed to determine the mechanical properties of skin tissue at back and abdomen locations of a rat body. The back and abdomen skins of eight rats are excised and subjected to a series of tensile tests. The elastic modulus, maximum stress, and strain of skin tissues are measured using three stress definitions and four strain definitions. The results show that the effect of varying the stress definition on the maximum stress measurements of the back skin is significant but not when calculating the elastic modulus and maximum strain. No significant effects are observed on the elastic modulus, maximum stress, and strain measurements of abdomen skin by varying the stress definition. In the true stress-strain diagram, the maximum stress (20%), and elastic modulus (35%) of back skin are significantly higher than that of abdomen skin. The true stress-strain definition is favored to measure the mechanical properties of skin tissue since it gives more accurate measurements of the skin's response using the instantaneous values. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Improved design and in-situ measurements of new beam position monitors for Indus-2

    Science.gov (United States)

    Kumar, M.; Babbar, L. K.; Holikatti, A. C.; Yadav, S.; Tyagi, Y.; Puntambekar, T. A.; Senecha, V. K.

    2018-01-01

    Beam position monitors (BPM) are important diagnostic devices used in particle accelerators to monitor position of the beam for various applications. Improved version of button electrode BPM has been designed using CST Studio Suite for Indus-2 ring. The new BPMs are designed to replace old BPMs which were designed and installed more than 12 years back. The improved BPMs have higher transfer impedance, resonance free output signal, equal sensitivity in horizontal and vertical planes and fast decaying wakefield as compared to old BPMs. The new BPMs have been calibrated using coaxial wire method. Measurement of transfer impedance and time domain signals has also been performed in-situ with electron beam during Indus-2 operation. The calibration and beam based measurements results showed close agreement with the design parameters. This paper presents design, electromagnetic simulations, calibration result and in-situ beam based measurements of newly designed BPMs.

  13. Stretching positions for the coracohumeral ligament: Strain measurement during passive motion using fresh/frozen cadaver shoulders

    Directory of Open Access Journals (Sweden)

    Izumi Tomoki

    2011-01-01

    Full Text Available Abstract Background Contracture of the coracohumeral ligament is reported to restrict external rotation of the shoulder with arm at the side and restrict posterior-inferior shift of the humeral head. The contracture is supposed to restrict range of motion of the glenohumeral joint. Methods To obtain stretching position of the coracohumeral ligament, strain on the ligament was measured at the superficial fibers of the ligament using 9 fresh/frozen cadaver shoulders. By sequential measurement using a strain gauge, the ligament strain was measured from reference length (L0. Shoulder positions were determined using a 3 Space Tracker System. Through a combination of previously reported coracohumeral stretching positions and those observed in preliminary measurement, ligament strain were measured by passive external rotation from 10° internal rotation, by adding each 10° external rotation, to maximal external rotation. Results Stretching positions in which significantly larger strain were obtained compared to the L0 values were 0° elevation in scapula plane with 40°, 50° and maximum external rotation (5.68%, 7.2%, 7.87%, 30° extension with 50°, maximum external rotation (4.20%, 4.79%, and 30° extension + adduction with 30°, 40°, 50° and maximum external rotation (4.09%, 4.67%, 4.78%, 5.05%(P Conclusions Significant strain of the coracohumeral ligament will be achieved by passive external rotation at lower shoulder elevations, extension, and extension with adduction.

  14. Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor.

    Science.gov (United States)

    Yu, Hao; Qian, Zheng; Liu, Huayi; Qu, Jiaqi

    2018-02-14

    This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.

  15. BIOCHEMICAL MECHANISMS OF MIXED EFFECT OF ELECTROMAGNETIC RADIATION AND LOW POSITIVE TEMPERATURE ON ANIMALS’ ORGANISM

    Directory of Open Access Journals (Sweden)

    Litovchenko O.L.

    2015-05-01

    change in the activity of catalase and a trend toward an increase in MDA level. Values of lipoprotein profile also did not have reliable changes, but high values of atherogenic index throughout the study showed the negative impact of EMR on lipid metabolism. Reliable changes in liver function tests indicated a disorder of liver detoxification function and possible derangement of protein metabolism. A decrease in creatinine and uric acid in the urine of rats is also evidence of this. The mixed effect of EMR and positive low temperature predetermined deeper violations practically in all components of metabolism, which exhibit low levels of SH-groups and the activity of catalase and superoxide dismutase, an increase in the concentration of ceruloplasmin. The observed increase in VLDL and triglycerides indicated the increase of the processes of atherogenesis. Acid phosphatase activity increased, increased alkaline phosphatase tends to raise the level of serum phosphorus levels in rats of the experimental group. There were more pronounced changes in the functioning of the liver. The level of urea in the blood serum was reliably increased. In the mixed action of EMR and positive low temperature, the level of uric acid in urine reliably increased, indicating that the development of renal failure in this group of animals, which was also indicated by elevated levels of chlorides in the urine. Conclusions. 1. The leading biochemical mechanisms of adverse effects of mixed action of EMR and positive low temperature is a disorder of the antioxidant system of blood, lipid metabolism and renal excretory function. 2. The mixed effect of EMR and positive low temperature on the organs and systems was more pronounced compared to the isolated action of electromagnetic radiation. 3. The above determines the need to consider the increase of biological effect of EMR established in the experiment on laboratory animals in the conditions of cold stress, when substantiating hygienic standards, the

  16. Bench calibration of INDUS-2 beam position indicators

    International Nuclear Information System (INIS)

    Tyagi, Y.; Banerji, Anil; Kotaiah, S.

    2005-01-01

    A third generation synchrotron radiation source of energy 2.5 GeV named INDUS-2 at Centre for Advanced Technology (C.A.T), Indore (M.P) is in the advanced stage of construction. Accurate determination and correction of beam closed orbit in INDUS-2 machine within 100 of microns is a very desirable goal. Bench based calibration of Beam Position Indicators (BPI) play a very important and useful role during initial commissioning of electron machines. To precisely measure transverse position of electron beam in the Indus-2 storage ring, 56 Beam Position Indicators (BPI) will be installed in INDUS-2 machine. Out of 56 Beam Position Indicators 40 are of individual type whereas 16 are integrated with dipole vacuum chamber. The Beam Position Indicators are required to be calibrated before they can be installed. The calibration is done to determine electrical offset with respect to defined mechanical centre, to determine displacement sensitivities as well as non linearity's of BPI. Ideally when beam passes through the geometrical center of BPI's, all electrodes should have same signal strength. However due to different capacitance of electrodes and offset and drift in electronics, the electrical centre (mechanical x, y where all electrodes shows same signal strength) differs from mechanical centre of BPI. A fully automatic calibration system has been developed to carry out the calibration of Beam Position Indicators. A calibration software has been developed which has necessary utilities to process and display calibration data and results. This paper describes the calibration results of Indus-2 BPM. (author)

  17. High mechanical Q-factor measurements on silicon bulk samples

    Energy Technology Data Exchange (ETDEWEB)

    Nawrodt, R; Zimmer, A; Koettig, T; Schwarz, C; Heinert, D; Hudl, M; Neubert, R; Thuerk, M; Nietzsche, S; Vodel, W; Seidel, P [Friedrich-Schiller-Universitaet, Institut fuer Festkoerperphysik, Helmholtzweg 5, D-07743 Jena (Germany); Tuennermann, A [Friedrich-Schiller-Universitaet, Institut fuer Angewandte Physik, Max-Wien-Platz 1, D-07743 Jena (Germany)], E-mail: ronny.nawrodt@uni-jena.de

    2008-07-15

    Future gravitational wave detectors will be limited by different kinds of noise. Thermal noise from the coatings and the substrate material will be a serious noise contribution within the detection band of these detectors. Cooling and the use of a high mechanical Q-factor material as a substrate material will reduce the thermal noise contribution from the substrates. Silicon is one of the most interesting materials for a third generation cryogenic detector. Due to the fact that the coefficient of thermal expansion vanishes at 18 and 125 K the thermoelastic contribution to the thermal noise will disappear. We present a systematic analysis of the mechanical Q-factor at low temperatures between 5 and 300 K on bulk silicon (100) samples which are boron doped. The thickness of the cylindrical samples is varied between 6, 12, 24, and 75mm with a constant diameter of 3 inches. For the 75mm substrate a comparison between the (100) and the (111) orientation is presented. In order to obtain the mechanical Q-factor a ring-down measurement is performed. Thus, the substrate is excited to resonant vibrations by means of an electrostatic driving plate and the subsequent ring-down is recorded using a Michelson-like interferometer. The substrate itself is suspended as a pendulum by means of a tungsten wire loop. All measurements are carried out in a special cryostat which provides a temperature stability of better than 0.1K between 5 and 300K during the experiment. The influence of the suspension on the measurements is experimentally investigated and discussed. At 5.8K a highest Q-factor of 4.5 x 10{sup 8} was achieved for the 14.9 kHz mode of a silicon (100) substrate with a diameter of 3 inches and a thickness of 12 mm.

  18. In-beam measurement of the position resolution of a highly segmented coaxial germanium detector

    International Nuclear Information System (INIS)

    Descovich, M.; Lee, I.Y.; Fallon, P.; Cromaz, M.; Macchiavelli, A.O.; Radford, D.C.; Vetter, K.; Clark, R.M.; Deleplanque, M.A.; Stephens, F.S.; Ward, D.

    2005-01-01

    The position resolution of a highly segmented coaxial germanium detector was determined by analyzing the 2055keV γ-ray transition of Zr90 excited in a fusion-evaporation reaction. The high velocity of the Zr90 nuclei imparted large Doppler shifts. Digital analysis of the detector signals recovered the energy and position of individual γ-ray interactions. The location of the first interaction in the crystal was used to correct the Doppler energy shift. Comparison of the measured energy resolution with simulations implied a position resolution (root mean square) of 2mm in three-dimensions

  19. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    Directory of Open Access Journals (Sweden)

    F. J. Cullinan

    2015-11-01

    Full Text Available The Compact Linear Collider (CLIC requires beam position monitors (BPMs with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3 at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2/3  ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  20. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    Science.gov (United States)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.; Lefevre, T.; Lunin, A.; Lyapin, A.; Søby, L.; Towler, J.; Wendt, M.

    2015-11-01

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2 /3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  1. A few nascent methods for measuring mechanical properties of the biological cell.

    Energy Technology Data Exchange (ETDEWEB)

    Thayer, Gayle Echo; de Boer, Maarten Pieter; Corvalan, Carlos (Purdue University, West Lafayette, IN); Corwin, Alex David; Campanella, Osvaldo H. (Purdue University, West Lafayette, IN); Nivens, David (Purdue University, West Lafayette, IN); Werely, Steven (Purdue University, West Lafayette, IN); Sumali, Anton Hartono; Koch, Steven John

    2006-01-01

    This report summarizes a survey of several new methods for obtaining mechanical and rheological properties of single biological cells, in particular: (1) The use of laser Doppler vibrometry (LDV) to measure the natural vibrations of certain cells. (2) The development of a novel micro-electro-mechanical system (MEMS) for obtaining high-resolution force-displacement curves. (3) The use of the atomic force microscope (AFM) for cell imaging. (4) The adaptation of a novel squeezing-flow technique to micro-scale measurement. The LDV technique was used to investigate the recent finding reported by others that the membranes of certain biological cells vibrate naturally, and that the vibration can be detected clearly with recent instrumentation. The LDV has been reported to detect motions of certain biological cells indirectly through the motion of a probe. In this project, trials on Saccharomyces cerevisiae tested and rejected the hypothesis that the LDV could measure vibrations of the cell membranes directly. The MEMS investigated in the second technique is a polysilicon surface-micromachined force sensor that is able to measure forces to a few pN in both air and water. The simple device consists of compliant springs with force constants as low as 0.3 milliN/m and Moire patterns for nanometer-scale optical displacement measurement. Fields from an electromagnet created forces on magnetic micro beads glued to the force sensors. These forces were measured and agreed well with finite element prediction. It was demonstrated that the force sensor was fully functional when immersed in aqueous buffer. These results show the force sensors can be useful for calibrating magnetic forces on magnetic beads and also for direct measurement of biophysical forces on-chip. The use of atomic force microscopy (AFM) for profiling the geometry of red blood cells was the third technique investigated here. An important finding was that the method commonly used for attaching the cells to a

  2. A sensorless method for measuring the point mobility of mechanical structures

    Science.gov (United States)

    Boulandet, R.; Michau, M.; Herzog, P.; Micheau, P.; Berry, A.

    2016-09-01

    This paper presents a convenient and cost-effective experimental tool for measuring the mobility characteristics of a mechanical structure. The objective is to demonstrate that the point mobility measurement can be performed using only an electrodynamic inertial exciter. Unlike previous work based on voice coil actuators, no load cell or accelerometer is needed. Instead, it is theoretically shown that the mobility characteristics of the structure can be estimated from variations in the electrical input impedance of the actuator fixed onto it, provided that the electromechanical parameters of the actuator are known. The proof of concept is made experimentally using a cheap commercially available actuator on a simply supported plate, leading to a good dynamic range from 100 Hz to 1 kHz. The methodology to assess the basic parameters of the actuator is also given. Measured data are compared to a standard shaker testing and the strengths and weaknesses of the sensorless mobility measuring device are discussed. It is believed that this sensorless mobility measuring device can be a convenient experimental tool to determine the dynamic characteristics of a wide range of mechanical structures.

  3. A High Dynamic-Range Beam Position Measurement System for ELSA-2

    CERN Document Server

    Balleyguier, P; Guimbal, P; Borrion, H

    2003-01-01

    New beamlines are presently under construction for ELSA, a 20 MeV electron linac located at Bruyères-le-Châtel. These lines need a beam position measurement system filling the following requirements: small footprint, wide dynamic range, single-bunch/multi-bunch capability, simple design. We designed a compact 4-stripline sensor and an electronic treatment chain based on logarithmic amplifiers. This paper presents the design, cold and hot test results.

  4. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Science.gov (United States)

    Uen, Sakir; Fimmers, Rolf; Brieger, Miriam; Nickenig, Georg; Mengden, Thomas

    2009-01-01

    Background Wrist blood pressure (BP) devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP) measurement methods: 1) office BP, 2) home BP (Omron wrist device HEM- 637 IT with position sensor), 3) 24-hour ambulatory BP(24-h ABPM) (ABPM-04, Meditech, Hun)conventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH)- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p ABPM (p ABPM was not significantly different (p = 0.80 systolic BP, p = 0.1 diastolic BP). The correlation coefficient of 24-h ABMP (r = 0.52) with left ventricular mass index was significantly higher than with office BP (r = 0.31). The difference between 24-h ABPM and home BP (r = 0.46) was not significant. Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have

  5. Nonlinear control of marine vehicles using only position and attitude measurements

    Energy Technology Data Exchange (ETDEWEB)

    Paulsen, Marit Johanne

    1996-12-31

    This thesis presents new results on the design and analysis of nonlinear output feedback controllers for auto pilots and dynamic positioning systems for ships and underwater vehicles. Only position and attitude measurements of the vehicle are used in the control design. The underlying idea of the work is to use certain structural properties of the equations of motion in the controller design and analysis. New controllers for regulation and tracking have been developed and the stability of the resulting closed-loop systems has been rigorously established. The results are supported by simulations. The following problems have been investigated covering design of passive controller for regulation, comparison of two auto pilots, nonlinear damping compensation for tracking, tracking control for nonlinear ships, and output tracking control with wave filtering for multivariable models of possibly unstable vehicles. 97 refs., 32 figs.

  6. The Virtual Fields Method Extracting Constitutive Mechanical Parameters from Full-field Deformation Measurements

    CERN Document Server

    Pierron, Fabrice

    2012-01-01

    The Virtual Fields Method: Extracting Constitutive Mechanical Parameters from Full-field Deformation Measurements is the first book on the Virtual Fields Method (VFM), a technique to identify materials mechanical properties from full-field measurements. Firmly rooted with extensive theoretical description of the method, the book presents numerous examples of application to a wide range of materials (composites, metals, welds, biomaterials) and situations (static, vibration, high strain rate). The authors give a detailed training section with examples of progressive difficulty to lead the reader to program the VFM and include a set of commented Matlab programs as well as GUI Matlab-based software for more general situations. The Virtual Fields Method: Extracting Constitutive Mechanical Parameters from Full-field Deformation Measurements is an ideal book for researchers, engineers, and students interested in applying the VFM to new situations motivated by their research.  

  7. Optimal Control Method of Robot End Position and Orientation Based on Dynamic Tracking Measurement

    Science.gov (United States)

    Liu, Dalong; Xu, Lijuan

    2018-01-01

    In order to improve the accuracy of robot pose positioning and control, this paper proposed a dynamic tracking measurement robot pose optimization control method based on the actual measurement of D-H parameters of the robot, the parameters is taken with feedback compensation of the robot, according to the geometrical parameters obtained by robot pose tracking measurement, improved multi sensor information fusion the extended Kalan filter method, with continuous self-optimal regression, using the geometric relationship between joint axes for kinematic parameters in the model, link model parameters obtained can timely feedback to the robot, the implementation of parameter correction and compensation, finally we can get the optimal attitude angle, realize the robot pose optimization control experiments were performed. 6R dynamic tracking control of robot joint robot with independent research and development is taken as experimental subject, the simulation results show that the control method improves robot positioning accuracy, and it has the advantages of versatility, simplicity, ease of operation and so on.

  8. Realization of Arbitrary Positive-Operator-Value Measurement of Single Atomic Qubit via Cavity QED

    International Nuclear Information System (INIS)

    Yang, Han; Wei, Wu; Chun-Wang, Wu; Hong-Yi, Dai; Cheng-Zu, Li

    2008-01-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given

  9. Realization of Arbitrary Positive-Operator-Value Measurement of Single Atomic Qubit via Cavity QED

    Science.gov (United States)

    Han, Yang; Wu, Wei; Wu, Chun-Wang; Dai, Hong-Yi; Li, Cheng-Zu

    2008-12-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given.

  10. Measuring the mechanical properties of molecular conformers

    Science.gov (United States)

    Jarvis, S. P.; Taylor, S.; Baran, J. D.; Champness, N. R.; Larsson, J. A.; Moriarty, P.

    2015-09-01

    Scanning probe-actuated single molecule manipulation has proven to be an exceptionally powerful tool for the systematic atomic-scale interrogation of molecular adsorbates. To date, however, the extent to which molecular conformation affects the force required to push or pull a single molecule has not been explored. Here we probe the mechanochemical response of two tetra(4-bromophenyl)porphyrin conformers using non-contact atomic force microscopy where we find a large difference between the lateral forces required for manipulation. Remarkably, despite sharing very similar adsorption characteristics, variations in the potential energy surface are capable of prohibiting probe-induced positioning of one conformer, while simultaneously permitting manipulation of the alternative conformational form. Our results are interpreted in the context of dispersion-corrected density functional theory calculations which reveal significant differences in the diffusion barriers for each conformer. These results demonstrate that conformational variation significantly modifies the mechanical response of even simple porpyhrins, potentially affecting many other flexible molecules.

  11. Conceptual Design of Angular Position Detector for Control Element Drive Mechanism of Small and Medium Reactor

    International Nuclear Information System (INIS)

    Yu, Je-Yong; Huh, Hyung; Kim, Ji-Ho; Choi, Suhn

    2007-01-01

    When the small and medium reactor is designed with a soluble boron free operation and nuclear heating for the reactor start-up, the design features require a Control Element Drive Mechanism (CEDM) to have a fine-step movement capability as well as a high reliability for a fine reactivity control. Also the reliability and accuracy of the information for the control rod position is important to the reactor safety as well as to design of the core protection system. The position signal of control rod is classified as a Class 1E because the rod position signal is used in the safety related systems. Therefore it will be separated from the control systems to the extent that a failure of any single control system component of a channel and shall have sufficient independence, redundancy, and testability to perform its safety functions assuming a single failure. The position indicator is composed of a permanent magnet, reed switches and a voltage divider. Four independent position indicators around the upper pressure housing provide an indication of the position of a control rod comprising of a permanent magnet with a magnetic field concentrator which moves with the extension shaft connected to the control rod. The zigzag arranged reed switches are positioned along a line parallel to the path of the movement of the permanent magnet and it is activated selectively when the permanent magnet passes by. A voltage divider electrically connected to the reed switches provides a signal commensurate with the position of the control rod. The signal may then be transmitted to a position indicating device. But position indicator can not recognize the malfunction of the rotary step motor of CEDM instantly because its signal output is changed after the control rod moves more than a distance of reed switch interval

  12. Nomarski imaging interferometry to measure the displacement field of micro-electro-mechanical systems

    International Nuclear Information System (INIS)

    Amiot, Fabien; Roger, Jean Paul

    2006-01-01

    We propose to use a Nomarski imaging interferometer to measure the out-of-plane displacement field of micro-electro-mechanical systems. It is shown that the measured optical phase arises from both height and slope gradients. By using four integrating buckets, a more efficient approach to unwrap the measured phase is presented,thus making the method well suited for highly curved objects. Slope and height effects are then decoupled by expanding the displacement field on a functions basis, and the inverse transformation is applied to get a displacement field from a measured optical phase map change with a mechanical loading. A measurement reproducibility of approximately 10 pm is achieved, and typical results are shown on a microcantilever under thermal actuation, thereby proving the ability of such a setup to provide a reliable full-field kinematic measurement without surface modification

  13. Dynamic performance of the beam position monitor support at the SSRF.

    Science.gov (United States)

    Wang, Xiao; Cao, Yun; Du, Hanwen; Yin, Lixin

    2009-01-01

    Electron beam stability is very important for third-generation light sources, especially for the Shanghai Synchrotron Radiation Facility whose ground vibrations are much larger than those for other light sources. Beam position monitors (BPMs), used to monitor the position of the electron beam, require a greater stability than other mechanical structures. This paper concentrates on an investigation of the dynamic performance of the BPM support prototype. Modal and response analyses have been carried out by finite-element (FE) calculations and vibration measurements. Inconsistent results between calculation and measurement have motivated a change in the soft connections between the support and the ground from a ground bolt in the initial design to full grout. As a result the mechanical stability of the BPM support is greatly improved, showing an increase in the first eigenfrequency from 20.2 Hz to 50.2 Hz and a decrease in the ratio of the root-mean-square displacement (4-50 Hz) between the ground and the top of the support from 4.36 to 1.23 in the lateral direction. An example is given to show how FE analysis can guide the mechanical design and dynamic measurements (i.e. it is not just used as a verification method). Similar ideas can be applied to improve the stability of other mechanical structures.

  14. Information-Measuring System to Control the Electrical and Mechanical Motor Parameters

    Directory of Open Access Journals (Sweden)

    K. S. Ermakov

    2015-01-01

    Full Text Available The article considers the issue of creating an information-measuring system for an asynchronous motor. The presented system allows ensuring the failure-free protection of electromotor, considerably reducing costs of its unplanned repair, and reduced economical loss from idle time of the electric motor.The developed system comprises a mathematical model and two subsystems to measure electrical and mechanical parameters of the asynchronous motor.The electrical subsystem comprises a FLUKE company recording multi-meter a signal from which passes through the block of intervals and coding and comes to PC.The mechanical subsystem uses technical tools of phase-chronometric method. This method developed at the department of Metrology and Interchangeability allows an increasing efficiency of developed informative-measuring system. Mathematical modeling is used to link information from subsystems (electrical and mechanical to electromotor construction.The work conducted mathematical modeling of some defects of electric motor, namely: rupture of rotor winding and line surge.The mathematical model in Mathcad was based on a modified formula of Kloss. It allows us to tie the average current value of the torque of the induction motor with shaft speed and take into account the effect of the frequency and voltage.The Matlab Simulink (the package for visual programming environment was used to simulate a rupture of the rotor winding. Simulation results showed how the phase currents of the electric motor changed with the winding rupture.The developed information-measuring system has a number of advantages over traditional systems used in this field (vibration-based diagnostics systems. It will allow an increasing efficiency of the system for diagnostics of electrical machines created on the basis of this information-measuring system.

  15. Optoelectronic device for the measurement of the absolute linear position in the micrometric displacement range

    Science.gov (United States)

    Morlanes, Tomas; de la Pena, Jose L.; Sanchez-Brea, Luis M.; Alonso, Jose; Crespo, Daniel; Saez-Landete, Jose B.; Bernabeu, Eusebio

    2005-07-01

    In this work, an optoelectronic device that provides the absolute position of a measurement element with respect to a pattern scale upon switch-on is presented. That means that there is not a need to perform any kind of transversal displacement after the startup of the system. The optoelectronic device is based on the process of light propagation passing through a slit. A light source with a definite size guarantees the relation of distances between the different elements that constitute our system and allows getting a particular optical intensity profile that can be measured by an electronic post-processing device providing the absolute location of the system with a resolution of 1 micron. The accuracy of this measuring device is restricted to the same limitations of any incremental position optical encoder.

  16. Effects of suture position on left ventricular fluid mechanics under mitral valve edge-to-edge repair.

    Science.gov (United States)

    Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming

    2014-01-01

    Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.

  17. Measuring attachment to life in old age: the Portuguese version of the Positive Valuation of Life Scale (Positive VOL).

    Science.gov (United States)

    Araújo, Lia; Ribeiro, Oscar; Teixeira, Laetitia; Azevedo, Maria João; Jopp, Daniela S; Rott, Christoph; Paúl, Constança

    2015-10-01

    This study aims to present the psychometric properties of the Portuguese version of the Positive Valuation of Life Scale (Lawton et al. in J Aging Ment Healt 13:3-31, 2001). Sample included 207 community-dwelling elders (129 women; M Age = 77.2 years, SD = 7.5). The data collection included the translated and adapted Portuguese version of Positive Valuation of Life Scale, Life Satisfaction Index Z, Meaning in Life Questionnaire and Geriatric Depression Scale. From exploratory factor analysis, two factors emerged, existential beliefs and perceived control, explaining 49 % of the total variance. Both factors were positively related with meaning in life and life satisfaction and negatively related with depression (p 0.75). The Portuguese version of Positive VOL Scale represents a reliable and valid measure to capture the subjective experience of attachment to one's life. The two-factor structure is an update to Lawton's previous work and in line with findings obtained in the USA (Dennis et al. in What is valuation of life for frail community-dwelling older adults: factor structure and criterion validity of the VOL, Thomas Jefferson University, Center for Applied Research on Aging and Health Research, 2005) and Japan (Nakagawa et al. in Shinrigaku Kenkyu 84:37-46, 2013). Future research is required to investigate VOL predictors and the potential changes toward the end of the life span.

  18. Cranial nerves neuropraxia after shoulder arthroscopy in beach chair position.

    Science.gov (United States)

    Cogan, A; Boyer, P; Soubeyrand, M; Hamida, F Ben; Vannier, J-L; Massin, P

    2011-05-01

    We report a case of neuropraxia of the 9th, 10th and 12th cranial nerve pairs after arthroscopic rotator cuff repair in the beach chair position. The elements in the medical file seem to exclude an intracranial cause of the lesions and support a mechanical, extracranial cause due to intubation and/or the beach chair position. This clinical case report shows the neurological risks of the beach chair position during arthroscopic shoulder surgery and presents the essential safety measures to prevent these risks. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  19. Effect of laser beam position on mechanical properties of F82H/SUS316L butt-joint welded by fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Serizawa, Hisashi, E-mail: serizawa@jwri.osaka-u.ac.jp [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Mori, Daiki; Ogiwara, Hiroyuki; Mori, Hiroaki [Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2014-10-15

    Highlights: • The micro hardness of weld metal in F82H/SUS316L joint partially decreases after PWHT by shifting beam position to SUS316L. • Charpy impact energy of F82H/SUS316L joint obviously increases after PWHT due to the release of residual stress. • The tensile strength of weld metal in F82H/SUS316L joint is higher than that of SUS316L. • The fiber laser welding seems to be one of the most candidate methods to join between F82H and SUS316L pipes practically. - Abstract: A dissimilar butt-joint between reduced activation ferritic/martensitic steel F82H and SUS316L austenitic stainless steel was made by 4 kW fiber laser and the influence of laser beam position on its mechanical properties before and after post-weld heat treatment (PWHT) was examined at room temperature. From the nano-indentation measurements and the microstructural observations, it is found that the micro hardness of weld metal partially decreases after PWHT by shifting beam position to SUS316L because its phase seems to move from only the martensitic phase to the mixture of austenitic and martensitic phases. In addition, Charpy impact test suggests that the impact energy slightly increases by shifting beam position before PWHT and obviously increases after PWHT due to the release of residual stress. Moreover, the tensile test indicates that the tensile strength of weld metal is higher than that of SUS316L and the fracture occurs at the base metal of SUS316L regardless of laser beam position.

  20. Mechanical stop mechanism for overcoming MEMS fabrication tolerances

    International Nuclear Information System (INIS)

    Hussein, Hussein; Bourbon, Gilles; Le Moal, Patrice; Lutz, Philippe; Haddab, Yassine

    2017-01-01

    A mechanical stop mechanism is developed in order to compensate MEMS fabrication tolerances in discrete positioning. The mechanical stop mechanism is designed to be implemented on SOI wafers using a common DRIE etching process. The various fabrication tolerances obtained due to the etching process are presented and discussed in the paper. The principle and design of the mechanism are then presented. Finally, experiments on microfabricated positioning prototypes show accurate steps unaffected by the fabrication tolerances. (technical note)

  1. Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children

    DEFF Research Database (Denmark)

    Ortqvist, Maria; Moström, Eva B; Roos, Ewa M.

    2011-01-01

    PURPOSE: The purposes of this study were to evaluate reliability of the Single-limb mini squat test (a dynamic measure of medio-lateral knee position) and the Quadriceps-angle (Q-angle) (a static measure of medio-lateral knee position), present paediatric reference values of the Q......-angle measurements was found. Reference values for the Q-angle (mean 13.5° (1.9)-15.3° (2.8)) varies with age and gender. No associations were found between dynamic and static measures. CONCLUSIONS: The Single-limb mini squat test showed a moderate reliability and the Q-angle showed a fair to moderate reliability......-angle, and evaluate the association between the tests. METHODS: Two hundred and forty-six healthy children (9-16 years) were included (intra/inter-rater reliability for Q-angle (n = 37/85) and for Single-limb mini squat test (n = 33/28)). Dynamic medio-lateral knee position was assessed by the Single-limb mini squat...

  2. Possible mechanisms in a multicomponent email guided positive psychology intervention to improve mental well-being, anxiety and depression : A multiple mediation model

    NARCIS (Netherlands)

    Schotanus-Dijkstra, Marijke; Pieterse, Marcel E.; Drossaert, Constance H.C.; Walburg, Jan A.; Bohlmeijer, Ernst T.

    2017-01-01

    The efficacy of several multicomponent positive psychology interventions (PPIs) have been demonstrated, but little is known about its possible mechanisms of change. We examined (1) the efficacy of an email guided self-help PPI on six core well-being processes (positive emotion, use of strengths,

  3. Influence of Radiographic Positioning on Canine Sacroiliac and Lumbosacral Angle Measurements.

    Science.gov (United States)

    Jones, Susan; Savage, Mason; Naughton, Brian; Singh, Susheela; Robertson, Ian; Roe, Simon C; Marcellin-Little, Denis J; Mathews, Kyle G

    2018-01-01

     To evaluate the influence of radiographic malpositioning on canine sacroiliac and lumbosacral inclination angles.  Using canine cadavers, lateral pelvic radiographs were acquired with the radiographic beam in a neutral position and then rotated 5, 10 and 15° to mimic rotational malpositioning. The focal point of the beam was then focused over the abdomen and again over mid-diaphysis of the femur to mimic an abdominal or femoral radiographic study.  Five degrees of rotational malpositioning did not influence measurements of sacroiliac or lumbosacral inclination, but malpositioning by more than 5° led to a significant decrease in both sacroiliac and lumbosacral angles. Moving the focal point to the femur significantly decreased the measured lumbosacral angle. Abdominally centred radiographs had no effect on lumbosacral and sacroiliac angle measurements.  When evaluating canine lumbosacral and sacroiliac angles radiographically, pelvic rotation of more than 5° should be avoided as should the use of lateral radiographs centred over the femur. Schattauer GmbH Stuttgart.

  4. Realization of arbitrary positive-operator-value measurement of single atomic qubit via cavity QED

    International Nuclear Information System (INIS)

    Han Yang; Wu Wei; Wu Chunwang; Dai Hongyi; Li Chengzu

    2008-01-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given. (authors)

  5. A mechanical rotator for neutron scattering measurements

    International Nuclear Information System (INIS)

    Thaler, A.; Northen, E.; Aczel, A. A.; MacDougall, G. J.

    2016-01-01

    We have designed and built a mechanical rotation system for use in single crystal neutron scattering experiments at low temperatures. The main motivation for this device is to facilitate the application of magnetic fields transverse to a primary training axis, using only a vertical cryomagnet. Development was done in the context of a triple-axis neutron spectrometer, but the design is such that it can be generalized to a number of different instruments or measurement techniques. Here, we discuss some of the experimental constraints motivating the design, followed by design specifics, preliminary experimental results, and a discussion of potential uses and future extension possibilities.

  6. Calibration of the OPAL jet chamber with UV laser beams. Measurement of the beam position with position-sensitive silicon diodes (PSD)

    International Nuclear Information System (INIS)

    Koch, J.

    1990-03-01

    The OPAL jet chamber is calibrated with tracks produced by UV laser beams. Lateral effect diodes are used for monitoring the laser beam location in the detector. These position sensitive detectors locate the point of impact in two dimensions by the charge division method. Measurements on several diodes were carried out in order to calibrate these devices and to investigate to observed pin-cushion distortion. Using the telegraphers equation suitable expressions were obtained for describing the observed behaviour. It was shown that the magnetic field of OPAL as well as the UV laser wavelength and puls duration had no influence on the position information. (orig.)

  7. Precise VLA positions and flux-density measurements of the Jupiter system

    International Nuclear Information System (INIS)

    Muhleman, D.O.; Berge, G.L.; Rudy, D.; Niell, A.E.

    1986-01-01

    VLA C array configuration observations at 2 and 6 cm are presented for Europa, Ganymede, and Callisto at eastern and western elongations with respect to Jupiter, which allowed measurements in right ascension and declination of the satellites with an rms precision of about + or - 0.03 arcsec. The transfer of the mean offsets of Ganymede to Jupiter yields offsets of -0.185 + or - 0.03 arcsec and -0.06 + or - 0.03 arcsec, with respect to JPL-DE-200, at the mean epoch of April 28, 1983; the large offset in right ascension is a combination of the Jupiter ephemeris error and the error in the frame tie of the Jovian planets with the VLBI system of precise positions which was used as the absolute reference frame for the observations. A significant error is noted in the orbital position of Callisto with respect to Ganymede. 12 references

  8. Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius

    International Nuclear Information System (INIS)

    Han, Man Seok; Song, Jae Yong; Lee, Hyun Kuk; Yu, Se Jong; Kim, Yong Kyun

    2009-01-01

    The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  9. Discriminant analysis of maintaining a vertical position in the water

    Directory of Open Access Journals (Sweden)

    Bratuša Zoran

    2015-01-01

    Full Text Available Water polo is the only sports game that takes place in the water. During the outplay, a vertical body position with the two basic mechanisms of the leg work - a breaststroke leg kick and an eggbeater leg kick, prevails. Starting from the significance of a vertical position during the game play, the methods of assessing physical preparedness of the athletes of all the categories also include the evaluation of maintaining a vertical position and consequently the load of the leg muscles. The measurements are performed during the maintenance of a vertical position (swimming in place through one of the specified mechanisms of leg work, i.e. a vertical position technique. The aim of this paper was to determine the application of different mechanisms of the leg kicks in maintaining a vertical position with young water polo players in relation to their position. The study included 29 selected junior water polo players (age_15.8 ± 0.8 years; BH_185.2 ± 5.3cm and BW_81.7 ± 7.7kg. The measurements were performed during the tests of swimming in place at the maximum intensity lasting 10 seconds, by the breaststroke and eggbeater leg kicks. The isometric tensiometry tests were used for the measurements. The results were analysed by the application of descriptive statistics, and the kinetic selection characteristic was defined by the application of discriminant analysis. Higher average values were achieved with the breaststroke leg kick technique Fmax, ImpF and RFD (avgFmaxLEGGBK =157.46±19.93N; avgImpF_LEGGBK =45.43±10.64Ns; avgRFD_LEGGBK=337.85±80.73N/s; avgFmaxLBKICK=227.18±49.17N; avgImpF_LBKICK=55.99±14.59Ns; avgRFD_LBKICK=545.47±159.15N/s. After discriminant analysis, the results have shown that the eggbeater leg kick is a selection technique, whereas the force - Fmax is a kinetic selection variable. Based on the obtained results and the analyses performed it may be concluded that a training factor dominant for maintaining a vertical position by

  10. Interaction between intra-abdominal pressure and positive-end expiratory pressure

    Directory of Open Access Journals (Sweden)

    Jamili Anbar Torquato

    2009-02-01

    Full Text Available OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H2O. The measurements were repeated after placing a 5 kg weight on the patients' belly. RESULTS: After the addition of 5 kg to the patients' belly at zero Positive-End Expiratory Pressure, both intra-abdominal pressure (p<0.001 and plateau pressures (p=0.005 increased significantly. Increasing the Positive-End Expiratory Pressure levels from zero to 10 cm H2O without weight on the belly did not result in any increase in intra-abdominal pressure (p=0.165. However, plateau pressures increased significantly (p< 0.001. Increasing Positive-End Expiratory Pressure from zero to 10 cm H2O and adding 5 kg to the belly increased intra-abdominal pressure from 8.7 to 16.8 (p<0.001 and plateau pressure from 18.26 to 27.2 (p<0.001. Maintaining Positive-End Expiratory Pressure at 10 cm H2O and placing 5 kg on the belly increased intra-abdominal pressure from 12.3 +/- 1.7 to 16.8 +/- 1.7 (p<0.001 but did not increase plateau pressure (26.6+/-1.2 to 27.2 +/-1.1 -p=0.83. CONCLUSIONS: The addition of a 5kg weight onto the abdomen significantly increased both IAP and the airway plateau pressure, confirming that intra-abdominal hypertension elevates the plateau pressure. However, plateau pressure alone cannot be considered a good indicator for the detection of elevated intra-abdominal pressure in patients under mechanical ventilation using PEEP. In these patients, the intra-abdominal pressure must also be measured.

  11. Laser metrology in fluid mechanics granulometry, temperature and concentration measurements

    CERN Document Server

    Boutier, Alain

    2013-01-01

    In fluid mechanics, non-intrusive measurements are fundamental in order to improve knowledge of the behavior and main physical phenomena of flows in order to further validate codes.The principles and characteristics of the different techniques available in laser metrology are described in detail in this book.Velocity, temperature and concentration measurements by spectroscopic techniques based on light scattered by molecules are achieved by different techniques: laser-induced fluorescence, coherent anti-Stokes Raman scattering using lasers and parametric sources, and absorption sp

  12. Measurement of the square measure of the pharynx and the positional diagnosis of airway obstruction during obstructive sleep apnea syndrome by dynamic MRI

    International Nuclear Information System (INIS)

    Ozuki, Taizo; Ohkubo, Yasuo; Abe, Kimihiko

    2000-01-01

    The purpose of this study was to apply dynamic MRI for the positional diagnosis of airway obstruction during snoring and sleep apnea and to compare the apnea hypopnea index (AHI) and the square measure of the pharynx obtained before and after laser-assisted uvula-palate-pharyngoplasty (LAUP). From December 1997 to October 1998, dynamic MRI and overnight monitoring were performed at the hospital of Tokyo Medical University on 42 patients who complained of snoring and symptoms related to sleep apnea syndrome (SAS). Of the 42 patients, four exhibited collapse at the position of the soft palate (soft palate type) as diagnosed by dynamic MRI, and four exhibited collapse at the position of the soft palate as well as the tongue (complex type). LAUP was performed on these eight patients with obstructive SAS (OSAS). After LAUP, the AHI of these eight patients with OSAS decreased significantly (p<0.05). The square measure of the pharynx of these eight patients was increased (p<0.01). The AHI of all four patients with soft-palate obstruction decreased, and the square measure of the pharynx of three of these four patients increased. The AHI of three of four patients with the complex type decreased, while the square measure of the pharynx of two of these four patients increased. (author)

  13. Measurement of the square measure of the pharynx and the positional diagnosis of airway obstruction during obstructive sleep apnea syndrome by dynamic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ozuki, Taizo; Ohkubo, Yasuo; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    2000-11-01

    The purpose of this study was to apply dynamic MRI for the positional diagnosis of airway obstruction during snoring and sleep apnea and to compare the apnea hypopnea index (AHI) and the square measure of the pharynx obtained before and after laser-assisted uvula-palate-pharyngoplasty (LAUP). From December 1997 to October 1998, dynamic MRI and overnight monitoring were performed at the hospital of Tokyo Medical University on 42 patients who complained of snoring and symptoms related to sleep apnea syndrome (SAS). Of the 42 patients, four exhibited collapse at the position of the soft palate (soft palate type) as diagnosed by dynamic MRI, and four exhibited collapse at the position of the soft palate as well as the tongue (complex type). LAUP was performed on these eight patients with obstructive SAS (OSAS). After LAUP, the AHI of these eight patients with OSAS decreased significantly (p<0.05). The square measure of the pharynx of these eight patients was increased (p<0.01). The AHI of all four patients with soft-palate obstruction decreased, and the square measure of the pharynx of three of these four patients increased. The AHI of three of four patients with the complex type decreased, while the square measure of the pharynx of two of these four patients increased. (author)

  14. Fundamental limits to position determination by concentration gradients.

    Directory of Open Access Journals (Sweden)

    Filipe Tostevin

    2007-04-01

    Full Text Available Position determination in biological systems is often achieved through protein concentration gradients. Measuring the local concentration of such a protein with a spatially varying distribution allows the measurement of position within the system. For these systems to work effectively, position determination must be robust to noise. Here, we calculate fundamental limits to the precision of position determination by concentration gradients due to unavoidable biochemical noise perturbing the gradients. We focus on gradient proteins with first-order reaction kinetics. Systems of this type have been experimentally characterised in both developmental and cell biology settings. For a single gradient we show that, through time-averaging, great precision potentially can be achieved even with very low protein copy numbers. As a second example, we investigate the ability of a system with oppositely directed gradients to find its centre. With this mechanism, positional precision close to the centre improves more slowly with increasing averaging time, and so longer averaging times or higher copy numbers are required for high precision. For both single and double gradients, we demonstrate the existence of optimal length scales for the gradients for which precision is maximized, as well as analyze how precision depends on the size of the concentration-measuring apparatus. These results provide fundamental constraints on the positional precision supplied by concentration gradients in various contexts, including both in developmental biology and also within a single cell.

  15. Simultaneous Measurement of Multiple Mechanical Properties of Single Cells Using AFM by Indentation and Vibration.

    Science.gov (United States)

    Zhang, Chuang; Shi, Jialin; Wang, Wenxue; Xi, Ning; Wang, Yuechao; Liu, Lianqing

    2017-12-01

    The mechanical properties of cells, which are the main characteristics determining their physical performance and physiological functions, have been actively studied in the fields of cytobiology and biomedical engineering and for the development of medicines. In this study, an indentation-vibration-based method is proposed to simultaneously measure the mechanical properties of cells in situ, including cellular mass (m), elasticity (k), and viscosity (c). The proposed measurement method is implemented based on the principle of forced vibration stimulated by simple harmonic force using an atomic force microscope (AFM) system integrated with a piezoelectric transducer as the substrate vibrator. The corresponding theoretical model containing the three mechanical properties is derived and used to perform simulations and calculations. Living and fixed human embryonic kidney 293 (HEK 293) cells were subjected to indentation and vibration to measure and compare their mechanical parameters and verify the proposed approach. The results that the fixed sample cells are more viscous and elastic than the living sample cells and the measured mechanical properties of cell are consistent within, but not outside of the central region of the cell, are in accordance with the previous studies. This work provides an approach to simultaneous measurement of the multiple mechanical properties of single cells using an integrated AFM system based on the principle force vibration and thickness-corrected Hertz model. This study should contribute to progress in biomedical engineering, cytobiology, medicine, early diagnosis, specific therapy and cell-powered robots.

  16. Mechanical Q-factor measurements on a test mass with a structured surface

    Energy Technology Data Exchange (ETDEWEB)

    Nawrodt, R [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Zimmer, A [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Koettig, T [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Clausnitzer, T [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Bunkowski, A [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Kley, E B [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Schnabel, R [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Danzmann, K [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Nietzsche, S [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Vodel, W [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Tuennermann, A [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Seidel, P [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany)

    2007-07-15

    We present mechanical Q-factors (quality factors) of a crystalline quartz test mass with a nano-structured surface, measured in the temperature regime from 5 to 300 K. The nano-structure was a grating with a period of 2 {mu}m and a depth of about 0.1 {mu}m. Comparative measurements were performed on the plain substrate and on the structured test mass with different numbers of SiO{sub 2}/Ta{sub 2}O{sub 5} coating layers. The measurements at different stages of the test mass fabrication process show that the surface distortion induced by the nanostructure does not severely lower the mechanical Q-factor of the substrate. Damping due to a multi-layer coating stack was found to be orders of magnitude higher. The results provide vital information concerning the potential usage of low-thermal noise nano-structured test masses in future generations of high-precision laser interferometers and in current attempts to measure quantum effects of macroscopic mirror oscillators.

  17. 3D computational mechanics elucidate the evolutionary implications of orbit position and size diversity of early amphibians.

    Directory of Open Access Journals (Sweden)

    Jordi Marcé-Nogué

    Full Text Available For the first time in vertebrate palaeontology, the potential of joining Finite Element Analysis (FEA and Parametrical Analysis (PA is used to shed new light on two different cranial parameters from the orbits to evaluate their biomechanical role and evolutionary patterns. The early tetrapod group of Stereospondyls, one of the largest groups of Temnospondyls is used as a case study because its orbits position and size vary hugely within the members of this group. An adult skull of Edingerella madagascariensis was analysed using two different cases of boundary and loading conditions in order to quantify stress and deformation response under a bilateral bite and during skull raising. Firstly, the variation of the original geometry of its orbits was introduced in the models producing new FEA results, allowing the exploration of the ecomorphology, feeding strategy and evolutionary patterns of these top predators. Secondly, the quantitative results were analysed in order to check if the orbit size and position were correlated with different stress patterns. These results revealed that in most of the cases the stress distribution is not affected by changes in the size and position of the orbit. This finding supports the high mechanical plasticity of this group during the Triassic period. The absence of mechanical constraints regarding the orbit probably promoted the ecomorphological diversity acknowledged for this group, as well as its ecological niche differentiation in the terrestrial Triassic ecosystems in clades as lydekkerinids, trematosaurs, capitosaurs or metoposaurs.

  18. 3D Computational Mechanics Elucidate the Evolutionary Implications of Orbit Position and Size Diversity of Early Amphibians

    Science.gov (United States)

    Marcé-Nogué, Jordi; Fortuny, Josep; De Esteban-Trivigno, Soledad; Sánchez, Montserrat; Gil, Lluís; Galobart, Àngel

    2015-01-01

    For the first time in vertebrate palaeontology, the potential of joining Finite Element Analysis (FEA) and Parametrical Analysis (PA) is used to shed new light on two different cranial parameters from the orbits to evaluate their biomechanical role and evolutionary patterns. The early tetrapod group of Stereospondyls, one of the largest groups of Temnospondyls is used as a case study because its orbits position and size vary hugely within the members of this group. An adult skull of Edingerella madagascariensis was analysed using two different cases of boundary and loading conditions in order to quantify stress and deformation response under a bilateral bite and during skull raising. Firstly, the variation of the original geometry of its orbits was introduced in the models producing new FEA results, allowing the exploration of the ecomorphology, feeding strategy and evolutionary patterns of these top predators. Secondly, the quantitative results were analysed in order to check if the orbit size and position were correlated with different stress patterns. These results revealed that in most of the cases the stress distribution is not affected by changes in the size and position of the orbit. This finding supports the high mechanical plasticity of this group during the Triassic period. The absence of mechanical constraints regarding the orbit probably promoted the ecomorphological diversity acknowledged for this group, as well as its ecological niche differentiation in the terrestrial Triassic ecosystems in clades as lydekkerinids, trematosaurs, capitosaurs or metoposaurs. PMID:26107295

  19. Characteristics and New Measurement Method of NCSFs of Individual Color Mechanisms of Human Vision

    International Nuclear Information System (INIS)

    Jing-Jing, Ge; Zhao-Qi, Wang; Yan, Wang; Kan-Xing, Zhao

    2010-01-01

    We propose a new method for determining neural contrast sensitivity functions (NCSFs) of isolated color mechanisms based on the measurements of wave-front aberrations and isoluminant color contrast sensitivity functions (CSFs). Compared with the traditional method, this technique avoids the coherent noise and speckle noise, which are brought by the interference of laser beams, and has great flexibility for the measurements of NCSF of different color mechanisms. Our experiments indicate that the mean NCSF and CSF of the red mechanism are higher than those of the green mechanism, respectively, while those of the blue mechanism are the lowest. However the relative heights of the peak of NCSF and CSF between red and green mechanisms vary in subjects. There are some individuals whose peak values of NCSF and/or CSF of green mechanism are higher than that of the red mechanism. The NCSFs and CSFs of isolated color mechanisms all exhibit the similar characteristics and variation tendency. With the statistical average, the NCSFs of the red, green and blue mechanisms are higher than the corresponding CSFs in the whole spatial frequency. Compared with the corresponding CSFs curves, the peaks of the NCSFs of isolated color mechanisms shift toward higher spatial frequencies, especially for that of blue mechanism which has a largest shift of 3.9c/deg

  20. Method to measure the position offset of multiple light spots in a distributed aperture laser angle measurement system.

    Science.gov (United States)

    Jing, Xiaoli; Cheng, Haobo; Xu, Chunyun; Feng, Yunpeng

    2017-02-20

    In this paper, an accurate measurement method of multiple spots' position offsets on a four-quadrant detector is proposed for a distributed aperture laser angle measurement system (DALAMS). The theoretical model is put forward, as well as the corresponding calculation method. This method includes two steps. First, as the initial estimation, integral approximation is applied to fit the distributed spots' offset function; second, the Boltzmann function is employed to compensate for the estimation error to improve detection accuracy. The simulation results attest to the correctness and effectiveness of the proposed method, and tolerance synthesis analysis of DALAMS is conducted to determine the maximum uncertainties of manufacturing and installation. The maximum angle error is less than 0.08° in the prototype distributed measurement system, which shows the stability and robustness for prospective applications.

  1. Multiphoton photochemical crosslinking-based fabrication of protein micropatterns with controllable mechanical properties for single cell traction force measurements

    Science.gov (United States)

    Tong, Ming Hui; Huang, Nan; Zhang, Wei; Zhou, Zhuo Long; Ngan, Alfonso Hing Wan; Du, Yanan; Chan, Barbara Pui

    2016-01-01

    Engineering 3D microstructures with predetermined properties is critical for stem cell niche studies. We have developed a multiphoton femtosecond laser-based 3D printing platform, which generates complex protein microstructures in minutes. Here, we used the platform to test a series of fabrication and reagent parameters in precisely controlling the mechanical properties of protein micropillars. Atomic force microscopy was utilized to measure the reduced elastic modulus of the micropillars, and transmission electron microscopy was used to visualize the porosity of the structures. The reduced elastic modulus of the micropillars associated positively and linearly with the scanning power. On the other hand, the porosity and pore size of the micropillars associated inversely and linearly with the scanning power and reagent concentrations. While keeping the elastic modulus constant, the stiffness of the micropillars was controlled by varying their height. Subsequently, the single cell traction forces of rabbit chondrocytes, human dermal fibroblasts, human mesenchymal stem cells, and bovine nucleus pulposus cells (bNPCs) were successfully measured by culturing the cells on micropillar arrays of different stiffness. Our results showed that the traction forces of all groups showed positive relationship with stiffness, and that the chondrocytes and bNPCs generated the highest and lowest traction forces, respectively.

  2. Flocking in Multi-Agent Systems with Multiple Virtual Leaders Based Only on Position Measurements

    International Nuclear Information System (INIS)

    Su Housheng

    2012-01-01

    Most existing flocking algorithms assume one single virtual leader and rely on information on both relative positions and relative velocities among neighboring agents. In this paper, the problem of controlling a flock of mobile autonomous agents to follow multiple virtual leaders is investigated by using only position information in the sense that agents with the same virtual leader asymptotically attain the same velocity and track the corresponding virtual leader based on only position measurements. A flocking algorithm is proposed under which every agent asymptotically attains its desired velocity, collision between agents can be avoided, and the final tight formation minimizes all agents' global potentials. A simulation example is presented to verify and illustrate the theoretical results. (general)

  3. [Study on schistosomiasis control measures in mobile boat fishermen. III. Construction and application of regional joint mechanism for schistosomiasis examination and treatment in boatmen].

    Science.gov (United States)

    Yang, Gao; Le-Ping, Sun; Yin-Ping, Zuo; Yu-Hui, Xu; Zheng-Qiu, Zhang; Yu-Cai, Ma; Jin-Bin, Gao; Xi-Guang, Zhu; Bo, Zheng; Guo-Jing, Yang; Qing-Biao, Hong; Kun, Yang; You-Sheng, Liang

    2011-10-01

    To construct the regional joint mechanism for schistosomiasis examination and treatment and the examination protocol among mobile boatmen, so as to provide effective measures for control of mobile infectious sources of schistosomiasis in the Yangtze River basin. According to the characteristics of the cargo frequent mobility of ships with fixed anchor points, the health, maritime and transport sections were jointly cooperated to set up sites for schistosomiasis examination and treatment in ship locks, wharfs and harbors. The infection of schistosomiasis was detected by means of rapid immunological screening and stool examination, and the regional joint mechanism was constructed. The sero-positives were traced for further parasitological examinations and treatment by using the regional joint network for schistosomiasis examination and treatment. The schistosome infections in boatmen were analyzed and compared between different examination and treatment sites and among different navigation coverage. A total of 16 sites for examination and treatment of schistosomiasis, including 5 fixed sites and 11 mobile sites, were set up in 12 townships of 6 districts (counties) of Yangzhou City. During a period between June and August, the examination of schistosomiasis was conducted in 40 sites, and of the 1 225 boatmen from 967 boats detected, 19 cases were sero-positive, with a positive rate of 1.55%. Among the 14 sero-positives examined, no stool positive patients were found. Among the 1 225 boatmen detected, 820 were from fixed sites and 405 from mobile sites, and 4 and 15 cases were found, respectively, with positive rates of 0.49% and 3.70%, respectively, and the sero-positive rate was higher in mobile sites and that in fixed sites. A total of 898 boatmen from the Yangtze River basin and 305 from the local inland rivers were examined, and 3 and 16 sero-positive cases were detected, respectively, with positive rates of 0.33% and 5.25%, respectively, and the sero-positive

  4. Mechanical model of human eye compliance for volumetric occlusion break surge measurements.

    Science.gov (United States)

    Dyk, David W; Miller, Kevin M

    2018-02-01

    To develop a mechanical model of human eye compliance for volumetric studies. Alcon Research, Ltd., Lake Forest, California, USA. Experimental study. Enucleated human eyes underwent pressurization and depressurization cycles with peak intraocular pressures (IOPs) of 60 to 100 mm Hg; anterior chamber pressure and volume changes were measured. Average net volume change curves were calculated as a function of IOP for each eye. Overall mean volumes were computed from each eye's average results at pressure points extrapolated over the range of 5 to 90 mm Hg. A 2-term exponential function was fit to these results. A fluid chamber with a displaceable piston was created as a mechanical model of this equation. A laser confocal displacement meter was used to measure piston displacement. A test bed incorporated the mechanical model with a mounted phacoemulsification probe and allowed for simulated occlusion breaks. Surge volume was calculated from piston displacement. An exponential function, V = C 1 × exp(C 2 × IOP) + C 3  × exp(C 4  × IOP) - V 0 , where V, the volume, was fit to the final depressurization curve obtained from 15 enucleated human eyes. The C 1 through C 4 values were -0.07141, -0.23055, -0.14972, and -0.02006, respectively. The equation was modeled using a piston system with 3 parallel springs that engaged serially. The mechanical model mimicked depressurization curves observed in human cadaver eyes. The resulting mechanical compliance model measured ocular volumetric changes and thus would be helpful in characterizing the postocclusion break surge response. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Bridging centrality: A new indicator to measure the positioning of actors in R&D networks

    Energy Technology Data Exchange (ETDEWEB)

    Scherngell, T.; Wanzenboeck, I.; Berge, L.

    2016-07-01

    In the recent past, we can observe growing interest in the STI community in the notion of positioning indicators, shifting emphasis to actors in the innovation process and their R&D inter-linkages with other actors. In relation to this, we suggest a new approach for assessing the positioning of actors relying on the notion of bridging centrality (BC). Based on the concept of bridging paths, i.e. a set of two links connecting three actors across three different aggregate nodes (e.g. organisations, regions or countries), we argue that triangulation in networks is a key issue for knowledge recombinations and the extension of an actor's knowledge base. As bridges are most often not empirically observable at the individual level of research teams, we propose an approximated BC measure that provides a flexible framework for dealing with the aggregation problem in positioning actors. Hereby, BC is viewed as a function of an aggregate node's (i) participation intensity in the network, (ii) its openness to other nodes (i.e. the relative outward orientation of network links), and iii) the diversification of links to other nodes. In doing so, we provide an integrative perspective that enables us to achieve a better understanding of the positioning of certain actors in R&D networks. An illustrative example on the co-patent network of European regions demonstrates the performance and usefulness of our BC measure for networks constructed at the aggregated level, i.e. regions in our example. A region's outward orientation and the diversification of its network links moderates the influence of regional scale on network centrality. This is a major strength of the measure, and it paves the way for future studies to examine the role of certain aggregate node's, and, by this, contributes to the debate on positioning indicators in the STI context. (Author)

  6. Precise mean sea level measurements using the Global Positioning System

    Science.gov (United States)

    Kelecy, Thomas M.; Born, George H.; Parke, Michael E.; Rocken, Christian

    1994-01-01

    This paper describes the results of a sea level measurement test conducted off La Jolla, California, in November of 1991. The purpose of this test was to determine accurate sea level measurements using a Global Positioning System (GPS) equipped buoy. These measurements were intended to be used as the sea level component for calibration of the ERS 1 satellite altimeter. Measurements were collected on November 25 and 28 when the ERS 1 satellite overflew the calibration area. Two different types of buoys were used. A waverider design was used on November 25 and a spar design on November 28. This provided the opportunity to examine how dynamic effects of the measurement platform might affect the sea level accuracy. The two buoys were deployed at locations approximately 1.2 km apart and about 15 km west of a reference GPS receiver located on the rooftop of the Institute of Geophysics and Planetary Physics at the Scripps Institute of Oceanography. GPS solutions were computed for 45 minutes on each day and used to produce two sea level time series. An estimate of the mean sea level at both locations was computed by subtracting tide gage data collected at the Scripps Pier from the GPS-determined sea level measurements and then filtering out the high-frequency components due to waves and buoy dynamics. In both cases the GPS estimate differed from Rapp's mean altimetric surface by 0.06 m. Thus, the gradient in the GPS measurements matched the gradient in Rapp's surface. These results suggest that accurate sea level can be determined using GPS on widely differing platforms as long as care is taken to determine the height of the GPS antenna phase center above water level. Application areas include measurement of absolute sea level, of temporal variations in sea level, and of sea level gradients (dominantly the geoid). Specific applications would include ocean altimeter calibration, monitoring of sea level in remote regions, and regional experiments requiring spatial and

  7. Position detectors, methods of detecting position, and methods of providing positional detectors

    Science.gov (United States)

    Weinberg, David M.; Harding, L. Dean; Larsen, Eric D.

    2002-01-01

    Position detectors, welding system position detectors, methods of detecting various positions, and methods of providing position detectors are described. In one embodiment, a welding system positional detector includes a base that is configured to engage and be moved along a curved surface of a welding work piece. At least one position detection apparatus is provided and is connected with the base and configured to measure angular position of the detector relative to a reference vector. In another embodiment, a welding system positional detector includes a weld head and at least one inclinometer mounted on the weld head. The one inclinometer is configured to develop positional data relative to a reference vector and the position of the weld head on a non-planar weldable work piece.

  8. In-situ measurement of mechanical properties of structural components using cyclic ball indentation technique

    International Nuclear Information System (INIS)

    Chatterjee, S.; Madhusoodanan, K.; Panwar, Sanjay; Rupani, B.B.

    2007-01-01

    Material properties of components change during service due to environmental conditions. Measurement of mechanical properties of the components is important for assessing their fitness for service. In many instances, it is not possible to remove sizable samples from the component for doing the measurement in laboratory. In-situ technique for measurement of mechanical properties has great significance in such cases. One of the nondestructive methods that can be adopted for in-situ application is based on cyclic ball indentation technique. It involves multiple indentation cycles (at the same penetration location) on a metallic surface by a spherical indenter. Each cycle consists of indentation, partial unload and reload sequences. Presently, commercial systems are available for doing indentation test on structural component for limited applications. But, there is a genuine need of remotely operable compact in-situ property measurement system. Considering the importance of such applications Reactor Engineering Division of BARC has developed an In-situ Property Measurement System (IProMS), which can be used for in-situ measurement of mechanical properties of a flat or tubular component. This paper highlights the basic theory of measurement, qualification tests on IProMS and results from tests done on flat specimens and tubular component. (author)

  9. The position dependent influence that sensitivity correction processing gives the signal-to-noise ratio measurement in parallel imaging

    International Nuclear Information System (INIS)

    Murakami, Koichi; Yoshida, Koji; Yanagimoto, Shinichi

    2012-01-01

    We studied the position dependent influence that sensitivity correction processing gave the signal-to-noise ratio (SNR) measurement of parallel imaging (PI). Sensitivity correction processing that referred to the sensitivity distribution of the body coil improved regional uniformity more than the sensitivity uniformity correction filter with a fixed correction factor. In addition, the position dependent influence to give the SNR measurement in PI was different from the sensitivity correction processing. Therefore, if we divide SNR of the sensitivity correction processing image by SNR of the original image in each pixel and calculate SNR ratio, we can show the position dependent influence that sensitivity correction processing gives the SNR measurement in PI. It is with an index of the sensitivity correction processing precision. (author)

  10. Indirect Measurement of Energy Density of Soft PZT Ceramic Utilizing Mechanical Stress

    Science.gov (United States)

    Unruan, Muangjai; Unruan, Sujitra; Inkong, Yutthapong; Yimnirun, Rattikorn

    2017-11-01

    This paper reports on an indirect measurement of energy density of soft PZT ceramic utilizing mechanical stress. The method works analogous to the Olsen cycle and allows for a large amount of electro-mechanical energy conversion. A maximum energy density of 350 kJ/m3/cycle was found under 0-312 MPa and 1-20 kV/cm of applied mechanical stress and electric field, respectively. The obtained result is substantially higher than the results reported in previous studies of PZT materials utilizing a direct piezoelectric effect.

  11. Eliciting and Measuring Betrayal Aversion using the BDM Mechanism*

    Science.gov (United States)

    Quercia, Simone

    2016-01-01

    Betrayal aversion has been operationalized as the evidence that subjects demand a higher risk premium to take social risks compared to natural risks. This evidence has been first shown by Bohnet and Zeckhauser (2004) using an adaptation of the Becker – DeGroot – Marschak mechanism (BDM, Becker et al. (1964)). We compare their implementation of the BDM mechanism with a new version designed to facilitate subjects’ comprehension. We find that, although the two versions produce different distributions of values, the size of betrayal aversion, measured as an average treatment difference between social and natural risk settings, is not different across the two versions. We further show that our implementation is preferable to use in practice as it reduces substantially subjects’ mistakes and the likelihood of noisy valuations. PMID:27366658

  12. Multi-scale mechanics of granular solids from grain-resolved X-ray measurements

    Science.gov (United States)

    Hurley, R. C.; Hall, S. A.; Wright, J. P.

    2017-11-01

    This work discusses an experimental technique for studying the mechanics of three-dimensional (3D) granular solids. The approach combines 3D X-ray diffraction and X-ray computed tomography to measure grain-resolved strains, kinematics and contact fabric in the bulk of a granular solid, from which continuum strains, grain stresses, interparticle forces and coarse-grained elasto-plastic moduli can be determined. We demonstrate the experimental approach and analysis of selected results on a sample of 1099 stiff, frictional grains undergoing multiple uniaxial compression cycles. We investigate the inter-particle force network, elasto-plastic moduli and associated length scales, reversibility of mechanical responses during cyclic loading, the statistics of microscopic responses and microstructure-property relationships. This work serves to highlight both the fundamental insight into granular mechanics that is furnished by combined X-ray measurements and describes future directions in the field of granular materials that can be pursued with such approaches.

  13. Online measurement of fluence and position for protontherapy beams

    International Nuclear Information System (INIS)

    Benati, C.; Boriano, A.

    2004-01-01

    Tumour therapy with proton beams has been used for several decades in many centers with very good results in terms of local control and overall survival. Typical pathologies treated with this technique are located in head and neck, eye, prostate and in general at big depths or close to critical organs. The Experimental Physics Department of the University of Turin and the local Section of INFN, in collaboration with INFN Laboratori Nazionali del Sud Catania and Centre de Protontherapie de Orsay Paris, have developed detector systems that allow the measurement of beam position and fluence, obtained in real time during beam delivery. The Centre in Catania (CATANA: Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been treating patients with eye pathologies since spring 2002 using a superconducting cyclotron accelerating protons up to 62 MeV

  14. Online measurement of fluence and position for protontherapy beams

    Energy Technology Data Exchange (ETDEWEB)

    Benati, C.; Boriano, A. [Torino Univ., Torino (Italy). Dipartimento di Fisica Sperimentale; Bourhaleb, F. [TERA Foundation, Novara (Italy)] [and others

    2004-10-01

    Tumour therapy with proton beams has been used for several decades in many centers with very good results in terms of local control and overall survival. Typical pathologies treated with this technique are located in head and neck, eye, prostate and in general at big depths or close to critical organs. The Experimental Physics Department of the University of Turin and the local Section of INFN, in collaboration with INFN Laboratori Nazionali del Sud Catania and Centre de Protontherapie de Orsay Paris, have developed detector systems that allow the measurement of beam position and fluence, obtained in real time during beam delivery. The Centre in Catania (CATANA: Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been treating patients with eye pathologies since spring 2002 using a superconducting cyclotron accelerating protons up to 62 MeV.

  15. Dynamic Modeling and Nonlinear Position Control of a Quadruped Robot with Theo Jansen Linkage Mechanisms and a Single Actuator

    Directory of Open Access Journals (Sweden)

    Shunsuke Nansai

    2015-01-01

    Full Text Available The Theo Jansen mechanism is gaining widespread popularity among the legged robotics community due to its scalable design, energy efficiency, low payload-to-machine-load ratio, bioinspired locomotion, and deterministic foot trajectory. In this paper, we perform for the first time the dynamic modeling and analysis on a four-legged robot driven by a single actuator and composed of Theo Jansen mechanisms. The projection method is applied to derive the equations of motion of this complex mechanical system and a position control strategy based on energy is proposed. Numerical simulations validate the efficacy of the designed controller, thus setting a theoretical basis for further investigations on Theo Jansen based quadruped robots.

  16. A Novel Approach to Measuring Muscle Mechanics in Vehicle Collision Conditions

    Directory of Open Access Journals (Sweden)

    Simon Krašna

    2017-06-01

    Full Text Available The aim of the study was to evaluate a novel approach to measuring neck muscle load and activity in vehicle collision conditions. A series of sled tests were performed on 10 healthy volunteers at three severity levels to simulate low-severity frontal impacts. Electrical activity—electromyography (EMG—and muscle mechanical tension was measured bilaterally on the upper trapezius. A novel mechanical contraction (MC sensor was used to measure the tension on the muscle surface. The neck extensor loads were estimated based on the inverse dynamics approach. The results showed strong linear correlation (Pearson’s coefficient = 0.821 between the estimated neck muscle load and the muscle tension measured with the MC sensor. The peak of the estimated neck muscle force delayed 0.2 ± 30.6 ms on average vs. the peak MC sensor signal compared to the average delay of 61.8 ± 37.4 ms vs. the peak EMG signal. The observed differences in EMG and MC sensor collected signals indicate that the MC sensor offers an additional insight into the analysis of the neck muscle load and activity in impact conditions. This approach enables a more detailed assessment of the muscle-tendon complex load of a vehicle occupant in pre-impact and impact conditions.

  17. Synthesis of dexterity measure of mechanisms by evolution of dissipative system

    Directory of Open Access Journals (Sweden)

    Grešl M.

    2007-11-01

    Full Text Available The paper deals with the new approach of solving traditional kinematical synthesis of mechanisms. The kinematical synthesis is reformulated as nonlinear dynamical problem. All searched parameters of the mechanism are in this dynamical dissipative system introduced as time-varying during motion of mechanism’s dimension iteration. The synthesis process is realized as the time evolution of such system. One of the most important objectives of the machine synthesis is the dexterity measure. The new approach is applied to optimization of this property.

  18. Kinematic analysis of in situ measurement during chemical mechanical planarization process

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hongkai; Wang, Tongqing; Zhao, Qian; Meng, Yonggang; Lu, Xinchun, E-mail: xclu@tsinghua.edu.cn [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China)

    2015-10-15

    Chemical mechanical planarization (CMP) is the most widely used planarization technique in semiconductor manufacturing presently. With the aid of in situ measurement technology, CMP tools can achieve good performance and stable productivity. However, the in situ measurement has remained unexplored from a kinematic standpoint. The available related resources for the kinematic analysis are very limited due to the complexity and technical secret. In this paper, a comprehensive kinematic analysis of in situ measurement is provided, including the analysis model, the measurement trajectory, and the measurement time of each zone of wafer surface during the practical CMP process. In addition, a lot of numerical calculations are performed to study the influences of main parameters on the measurement trajectory and the measurement velocity variation of the probe during the measurement process. All the efforts are expected to improve the in situ measurement system and promote the advancement in CMP control system.

  19. Combined Effects of Ventilation Mode and Positive End-Expiratory Pressure on Mechanics, Gas Exchange and the Epithelium in Mice with Acute Lung Injury

    Science.gov (United States)

    Thammanomai, Apiradee; Hamakawa, Hiroshi; Bartolák-Suki, Erzsébet; Suki, Béla

    2013-01-01

    The accepted protocol to ventilate patients with acute lung injury is to use low tidal volume (VT) in combination with recruitment maneuvers or positive end-expiratory pressure (PEEP). However, an important aspect of mechanical ventilation has not been considered: the combined effects of PEEP and ventilation modes on the integrity of the epithelium. Additionally, it is implicitly assumed that the best PEEP-VT combination also protects the epithelium. We aimed to investigate the effects of ventilation mode and PEEP on respiratory mechanics, peak airway pressures and gas exchange as well as on lung surfactant and epithelial cell integrity in mice with acute lung injury. HCl-injured mice were ventilated at PEEPs of 3 and 6 cmH2O with conventional ventilation (CV), CV with intermittent large breaths (CVLB) to promote recruitment, and a new mode, variable ventilation, optimized for mice (VVN). Mechanics and gas exchange were measured during ventilation and surfactant protein (SP)-B, proSP-B and E-cadherin levels were determined from lavage and lung homogenate. PEEP had a significant effect on mechanics, gas exchange and the epithelium. The higher PEEP reduced lung collapse and improved mechanics and gas exchange but it also down regulated surfactant release and production and increased epithelial cell injury. While CVLB was better than CV, VVN outperformed CVLB in recruitment, reduced epithelial injury and, via a dynamic mechanotransduction, it also triggered increased release and production of surfactant. For long-term outcome, selection of optimal PEEP and ventilation mode may be based on balancing lung physiology with epithelial injury. PMID:23326543

  20. Mechanism of action of recombinant acc-royalisin from royal jelly of Asian honeybee against gram-positive bacteria.

    Directory of Open Access Journals (Sweden)

    Lirong Shen

    Full Text Available The antibacterial activity of royalisin, an antimicrobial peptide from the royal jelly produced by honeybees, has been addressed extensively. However, its mechanism of action remains unclear. In this study, a recombinant royalisin, RAcc-royalisin from the royal jelly of Asian honeybee Apis cerana cerana, was expressed by fusing with glutathione S-transferase (GST in Escherichia coli BL21, isolated and purified. The agar dilution assays with inhibition zone showed that RAcc-royalisin, similar to nisin, inhibits the growth of Gram-positive bacteria. The antibacterial activity of RAcc-royalisin was associated with its concentration, and was weakened by heat treatment ranging from 55°C to 85°C for 15 min. Both RAcc-royalisin and nisin exhibited the minimum inhibitory concentrations (MIC of 62.5 µg/ml, 125 µg/ml, and 250 µg/ml against Gram-positive bacterial strains, Bacillus subtilis and Micrococcus flavus and Staphyloccocus aureus in the microplate assay, respectively. However, RAcc-royalisin did not show antimicrobial activity against tested Gram-negative bacterial and fungal strains. The antibacterial activity of RAcc-royalisin agrees well with the decrease in bacterial cell hydrophobicity, the leakage of 260-nm absorbing materials, and the observation by transmission electron microscopy, all indicating that RAcc-royalisin induced the disruption and dysfunction of cell walls and membranes. This is the first report detailing the antibacterial mechanism of royalisin against Gram-positive bacteria, and provides insight into the application of recombinant royalisin in food and pharmaceutical industries as an antimicrobial agent.

  1. Study of Measurement Strategies of Geometric Deviation of the Position of the Threaded Holes

    Science.gov (United States)

    Drbul, Mário; Martikan, Pavol; Sajgalik, Michal; Czan, Andrej; Broncek, Jozef; Babik, Ondrej

    2017-12-01

    Verification of product and quality control is an integral part of current production process. In terms of functional requirements and product interoperability, it is necessary to analyze their dimensional and also geometric specifications. Threaded holes are verified elements too, which are a substantial part of detachable screw connections and have a broad presence in engineering products. This paper deals with on the analysing of measurement strategies of verification geometric deviation of the position of the threaded holes, which are the indirect method of measuring threaded pins when applying different measurement strategies which can affect the result of the verification of the product..

  2. Measuring Global Position Using the Sun

    Science.gov (United States)

    Murphy, Evan; Hughes, Stephen

    2014-01-01

    The determination of latitude and longitude on Earth has always been of interest to explorers and cartographers alike. Accurate positional information is often needed for rescue purposes in locations where satellite navigational systems are inoperable. The activity described in this paper demonstrates a simple procedure to determine latitude and…

  3. Analysis of antenna position measurements and weather station network data during the ALMA long baseline campaign of 2015

    Science.gov (United States)

    Hunter, Todd R.; Lucas, Robert; Broguière, Dominique; Fomalont, Ed B.; Dent, William R. F.; Phillips, Neil; Rabanus, David; Vlahakis, Catherine

    2016-07-01

    In a radio interferometer, the geometrical antenna positions are determined from measurements of the observed delay to each antenna from observations across the sky of many point sources whose positions are known to high accuracy. The determination of accurate antenna positions relies on accurate calibration of the dry and wet delay of the atmosphere above each antenna. For the Atacama Large Millimeter/Submillimeter Array (ALMA), with baseline lengths up to 15 kilometers, the geography of the site forces the height above mean sea level of the more distant antenna pads to be significantly lower than the central array. Thus, both the ground level meteorological values and the total water column can be quite different between antennas in the extended configurations. During 2015, a network of six additional weather stations was installed to monitor pressure, temperature, relative humidity and wind velocity, in order to test whether inclusion of these parameters could improve the repeatability of antenna position determinations in these configurations. We present an analysis of the data obtained during the ALMA Long Baseline Campaign of October through November 2015. The repeatability of antenna position measurements typically degrades as a function of antenna distance. Also, the scatter is more than three times worse in the vertical direction than in the local tangent plane, suggesting that a systematic effect is limiting the measurements. So far we have explored correcting the delay model for deviations from hydrostatic equilibrium in the measured air pressure and separating the partial pressure of water from the total pressure using water vapor radiometer (WVR) data. Correcting for these combined effects still does not provide a good match to the residual position errors in the vertical direction. One hypothesis is that the current model of water vapor may be too simple to fully remove the day-to-day variations in the wet delay. We describe possible new avenues of

  4. Microbial Metabolism in Soil at Subzero Temperatures: Adaptation Mechanisms Revealed by Position-Specific 13C Labeling

    Directory of Open Access Journals (Sweden)

    Ezekiel K. Bore

    2017-05-01

    Full Text Available Although biogeochemical models designed to simulate carbon (C and nitrogen (N dynamics in high-latitude ecosystems incorporate extracellular parameters, molecular and biochemical adaptations of microorganisms to freezing remain unclear. This knowledge gap hampers estimations of the C balance and ecosystem feedback in high-latitude regions. To analyze microbial metabolism at subzero temperatures, soils were incubated with isotopomers of position-specifically 13C-labeled glucose at three temperatures: +5 (control, -5, and -20°C. 13C was quantified in CO2, bulk soil, microbial biomass, and dissolved organic carbon (DOC after 1, 3, and 10 days and also after 30 days for samples at -20°C. Compared to +5°C, CO2 decreased 3- and 10-fold at -5 and -20°C, respectively. High 13C recovery in CO2 from the C-1 position indicates dominance of the pentose phosphate pathway at +5°C. In contrast, increased oxidation of the C-4 position at subzero temperatures implies a switch to glycolysis. A threefold higher 13C recovery in microbial biomass at -5 than +5°C points to synthesis of intracellular compounds such as glycerol and ethanol in response to freezing. Less than 0.4% of 13C was recovered in DOC after 1 day, demonstrating complete glucose uptake by microorganisms even at -20°C. Consequently, we attribute the fivefold higher extracellular 13C in soil than in microbial biomass to secreted antifreeze compounds. This suggests that with decreasing temperature, intracellular antifreeze protection is complemented by extracellular mechanisms to avoid cellular damage by crystallizing water. The knowledge of sustained metabolism at subzero temperatures will not only be useful for modeling global C dynamics in ecosystems with periodically or permanently frozen soils, but will also be important in understanding and controlling the adaptive mechanisms of food spoilage organisms.

  5. Precise Positioning of Uavs - Dealing with Challenging Rtk-Gps Measurement Conditions during Automated Uav Flights

    Science.gov (United States)

    Zimmermann, F.; Eling, C.; Klingbeil, L.; Kuhlmann, H.

    2017-08-01

    For some years now, UAVs (unmanned aerial vehicles) are commonly used for different mobile mapping applications, such as in the fields of surveying, mining or archeology. To improve the efficiency of these applications an automation of the flight as well as the processing of the collected data is currently aimed at. One precondition for an automated mapping with UAVs is that the georeferencing is performed directly with cm-accuracies or better. Usually, a cm-accurate direct positioning of UAVs is based on an onboard multi-sensor system, which consists of an RTK-capable (real-time kinematic) GPS (global positioning system) receiver and additional sensors (e.g. inertial sensors). In this case, the absolute positioning accuracy essentially depends on the local GPS measurement conditions. Especially during mobile mapping applications in urban areas, these conditions can be very challenging, due to a satellite shadowing, non-line-of sight receptions, signal diffraction or multipath effects. In this paper, two straightforward and easy to implement strategies will be described and analyzed, which improve the direct positioning accuracies for UAV-based mapping and surveying applications under challenging GPS measurement conditions. Based on a 3D model of the surrounding buildings and vegetation in the area of interest, a GPS geometry map is determined, which can be integrated in the flight planning process, to avoid GPS challenging environments as far as possible. If these challenging environments cannot be avoided, the GPS positioning solution is improved by using obstruction adaptive elevation masks, to mitigate systematic GPS errors in the RTK-GPS positioning. Simulations and results of field tests demonstrate the profit of both strategies.

  6. Poster - 35: Monitoring patient positioning during deep inspiration breath hold with a distance measuring laser

    International Nuclear Information System (INIS)

    Weston, Mark; Juhasz, Janos

    2016-01-01

    Purpose: The accuracy of treatment delivery for left breast/chest wall patients using deep inspiration breath hold (DIBH) is being monitored using a distance measuring laser (DML) Methods: A commercially available DML (DLS-C15, Dimetix) was mounted behind a Varian TrilogyTM linac. Relative to the machine isocenter, the laser from the beam was offset by 8 cm to the left and by 1 cm in the superior direction. This position was selected because this point is situated on the sternum for the majority of the left breast/chest-wall patients treated at our institution. The Varian Real-Time Positioning Management™ (RPM) guided DIBH treatments at our institution is delivered by placing the system’s tracking block on the patient’s abdomen. The treatment beam is enabled only when the block is in between a predefined abdomen motion range as determined during the CT simulation process. A LabVIEW program was developed to record both beam status (i.e. on/off) and distance measurements. In this study the DML was only used to monitor the position of a single point on the chest and no clinical decisions/adjustments were made based on these measurements. Results and Conclusions: Thus far, 34 fractions have been recorded for 4 patients. As such, the performance of our DIBH treatment technique cannot be fairly evaluated at this point. However, deviations between expected and measured distances have been observed and if these are found to be reproducible, then modifications in our treatment procedures and policies will have to take place.

  7. Poster - 35: Monitoring patient positioning during deep inspiration breath hold with a distance measuring laser

    Energy Technology Data Exchange (ETDEWEB)

    Weston, Mark; Juhasz, Janos [Juravinski Cancer Centre (Canada)

    2016-08-15

    Purpose: The accuracy of treatment delivery for left breast/chest wall patients using deep inspiration breath hold (DIBH) is being monitored using a distance measuring laser (DML) Methods: A commercially available DML (DLS-C15, Dimetix) was mounted behind a Varian TrilogyTM linac. Relative to the machine isocenter, the laser from the beam was offset by 8 cm to the left and by 1 cm in the superior direction. This position was selected because this point is situated on the sternum for the majority of the left breast/chest-wall patients treated at our institution. The Varian Real-Time Positioning Management™ (RPM) guided DIBH treatments at our institution is delivered by placing the system’s tracking block on the patient’s abdomen. The treatment beam is enabled only when the block is in between a predefined abdomen motion range as determined during the CT simulation process. A LabVIEW program was developed to record both beam status (i.e. on/off) and distance measurements. In this study the DML was only used to monitor the position of a single point on the chest and no clinical decisions/adjustments were made based on these measurements. Results and Conclusions: Thus far, 34 fractions have been recorded for 4 patients. As such, the performance of our DIBH treatment technique cannot be fairly evaluated at this point. However, deviations between expected and measured distances have been observed and if these are found to be reproducible, then modifications in our treatment procedures and policies will have to take place.

  8. A Foot-Mounted Inertial Measurement Unit (IMU) Positioning Algorithm Based on Magnetic Constraint.

    Science.gov (United States)

    Wang, Yan; Li, Xin; Zou, Jiaheng

    2018-03-01

    With the development of related applications, indoor positioning techniques have been more and more widely developed. Based on Wi-Fi, Bluetooth low energy (BLE) and geomagnetism, indoor positioning techniques often rely on the physical location of fingerprint information. The focus and difficulty of establishing the fingerprint database are in obtaining a relatively accurate physical location with as little given information as possible. This paper presents a foot-mounted inertial measurement unit (IMU) positioning algorithm under the loop closure constraint based on magnetic information. It can provide relatively reliable position information without maps and geomagnetic information and provides a relatively accurate coordinate for the collection of a fingerprint database. In the experiment, the features extracted by the multi-level Fourier transform method proposed in this paper are validated and the validity of loop closure matching is tested with a RANSAC-based method. Moreover, the loop closure detection results show that the cumulative error of the trajectory processed by the graph optimization algorithm is significantly suppressed, presenting a good accuracy. The average error of the trajectory under loop closure constraint is controlled below 2.15 m.

  9. A Foot-Mounted Inertial Measurement Unit (IMU Positioning Algorithm Based on Magnetic Constraint

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2018-03-01

    Full Text Available With the development of related applications, indoor positioning techniques have been more and more widely developed. Based on Wi-Fi, Bluetooth low energy (BLE and geomagnetism, indoor positioning techniques often rely on the physical location of fingerprint information. The focus and difficulty of establishing the fingerprint database are in obtaining a relatively accurate physical location with as little given information as possible. This paper presents a foot-mounted inertial measurement unit (IMU positioning algorithm under the loop closure constraint based on magnetic information. It can provide relatively reliable position information without maps and geomagnetic information and provides a relatively accurate coordinate for the collection of a fingerprint database. In the experiment, the features extracted by the multi-level Fourier transform method proposed in this paper are validated and the validity of loop closure matching is tested with a RANSAC-based method. Moreover, the loop closure detection results show that the cumulative error of the trajectory processed by the graph optimization algorithm is significantly suppressed, presenting a good accuracy. The average error of the trajectory under loop closure constraint is controlled below 2.15 m.

  10. Time as a Measure: Elementary Students Positioning the Hands of an Analog Clock

    Directory of Open Access Journals (Sweden)

    Darrell Earnest

    2018-06-01

    Full Text Available Elementary students have difficulty with the topic of time. The present study investigated students’ actions to position hour and minute hands on an analog clock to indicate particular times of the day. Using one-on-one interviews with students in Grades 2 and 4 (n = 48, we analyzed whether students were more accurate for one hand indicator (hour or minute versus the other as well as their solution approaches as they positioned each hand. We first present a quantitative analysis of student performance to document whether hour and minute hands posed differential challenges for students as they positioned hands to indicate particular times. Results indicate the hour hand is significantly more challenging to position accurately than the minute hand. Students’ solutions reflected varied approaches, including consideration of the quantitative hour-minute multiplicative relationship, attention to part-whole relations, and matching numbers from the provided time to numerals on the clock. We discuss implications for theory and instruction, including the relationship of time to length measure learning trajectories and the current treatment of time in K-12 mathematics standards for the United States.

  11. Selective Linear or Quadratic Optomechanical Coupling via Measurement

    Directory of Open Access Journals (Sweden)

    Michael R. Vanner

    2011-11-01

    Full Text Available The ability to engineer both linear and nonlinear coupling with a mechanical resonator is an important goal for the preparation and investigation of macroscopic mechanical quantum behavior. In this work, a measurement based scheme is presented where linear or square mechanical-displacement coupling can be achieved using the optomechanical interaction that is linearly proportional to the mechanical position. The resulting square-displacement measurement strength is compared to that attainable in the dispersive case that has a direct interaction with the mechanical-displacement squared. An experimental protocol and parameter set are discussed for the generation and observation of non-Gaussian states of motion of the mechanical element.

  12. Linear positivity and virtual probability

    International Nuclear Information System (INIS)

    Hartle, James B.

    2004-01-01

    We investigate the quantum theory of closed systems based on the linear positivity decoherence condition of Goldstein and Page. The objective of any quantum theory of a closed system, most generally the universe, is the prediction of probabilities for the individual members of sets of alternative coarse-grained histories of the system. Quantum interference between members of a set of alternative histories is an obstacle to assigning probabilities that are consistent with the rules of probability theory. A quantum theory of closed systems therefore requires two elements: (1) a condition specifying which sets of histories may be assigned probabilities and (2) a rule for those probabilities. The linear positivity condition of Goldstein and Page is the weakest of the general conditions proposed so far. Its general properties relating to exact probability sum rules, time neutrality, and conservation laws are explored. Its inconsistency with the usual notion of independent subsystems in quantum mechanics is reviewed. Its relation to the stronger condition of medium decoherence necessary for classicality is discussed. The linear positivity of histories in a number of simple model systems is investigated with the aim of exhibiting linearly positive sets of histories that are not decoherent. The utility of extending the notion of probability to include values outside the range of 0-1 is described. Alternatives with such virtual probabilities cannot be measured or recorded, but can be used in the intermediate steps of calculations of real probabilities. Extended probabilities give a simple and general way of formulating quantum theory. The various decoherence conditions are compared in terms of their utility for characterizing classicality and the role they might play in further generalizations of quantum mechanics

  13. POVMs: a small but important step beyond standard quantum mechanics

    NARCIS (Netherlands)

    Muynck, de W.M.; Nieuwenhuizen, T.M.; Spicka, V.; Mehmani, B.; et al., xx

    2007-01-01

    It is the purpose of the present contribution to demonstrate that the generalization of the concept of a quantum mechanical oservable from the Hermitian operator of standard quantum mechanics to a positive operator-valued measure is not a peripheral issue, allegedly to be understood in terms of a

  14. Positive and negative streamers in ambient air: measuring diameter, velocity and dissipated energy

    International Nuclear Information System (INIS)

    Briels, T M P; Kos, J; Van Veldhuizen, E M; Ebert, U; Winands, G J J

    2008-01-01

    Positive and negative streamers are studied in ambient air at 1 bar; they emerge from a needle electrode placed 40 mm above a planar electrode. The amplitudes of the applied voltage pulses range from 5 to 96 kV; most pulses have rise times of 30 ns or shorter. Diameters, velocities and energies of the streamers are measured. Two regimes are identified; a low voltage regime where only positive streamers appear and a high voltage regime where both positive and negative streamers exist. Below 5 kV, no streamers emerge. In the range from 5 to 40 kV, positive streamers form, while the negative discharges only form a glowing cloud at the electrode tip, but no streamers. For 5-20 kV, diameters and velocities of the positive streamers have the minimal values of d = 0.2 mm and v ∼ 10 5 m s -1 . For 20-40 kV, their diameters increase by a factor of 6 while the voltage increases only by a factor of 2. Above the transition value of 40 kV, streamers of both polarities form; they strongly resemble each other, though the positive ones propagate further; their diameters continue to increase with applied voltage. For 96 kV, positive streamers attain diameters of 3 mm and velocities of 4 x 10 6 m s -1 ; negative streamers are about 20% slower and thinner. An empirical fit formula for the relation between velocity v and diameter d is v = 0.5d 2 mm -1 ns -1 for both polarities. Streamers of both polarities dissipate energies of the order of several millijoules per streamer while crossing the gap.

  15. Underlying Mechanisms of Cooperativity, Input Specificity, and Associativity of Long-Term Potentiation Through a Positive Feedback of Local Protein Synthesis

    Directory of Open Access Journals (Sweden)

    Lijie Hao

    2018-05-01

    Full Text Available Long-term potentiation (LTP is a specific form of activity-dependent synaptic plasticity that is a leading mechanism of learning and memory in mammals. The properties of cooperativity, input specificity, and associativity are essential for LTP; however, the underlying mechanisms are unclear. Here, based on experimentally observed phenomena, we introduce a computational model of synaptic plasticity in a pyramidal cell to explore the mechanisms responsible for the cooperativity, input specificity, and associativity of LTP. The model is based on molecular processes involved in synaptic plasticity and integrates gene expression involved in the regulation of neuronal activity. In the model, we introduce a local positive feedback loop of protein synthesis at each synapse, which is essential for bimodal response and synapse specificity. Bifurcation analysis of the local positive feedback loop of brain-derived neurotrophic factor (BDNF signaling illustrates the existence of bistability, which is the basis of LTP induction. The local bifurcation diagram provides guidance for the realization of LTP, and the projection of whole system trajectories onto the two-parameter bifurcation diagram confirms the predictions obtained from bifurcation analysis. Moreover, model analysis shows that pre- and postsynaptic components are required to achieve the three properties of LTP. This study provides insights into the mechanisms underlying the cooperativity, input specificity, and associativity of LTP, and the further construction of neural networks for learning and memory.

  16. Measurement of resonance modes causative of beam position monitor signal noise in vacuum chamber of storage ring

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Youngdo; Hwang, Ilmoon; Park, Sungju [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Kim, Changbum, E-mail: chbkim@postech.ac.k [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2011-05-11

    It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S{sub 21}) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.

  17. Measurement of resonance modes causative of beam position monitor signal noise in vacuum chamber of storage ring

    International Nuclear Information System (INIS)

    Joo, Youngdo; Hwang, Ilmoon; Park, Sungju; Kim, Changbum

    2011-01-01

    It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S 21 ) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.

  18. Introduction to electronic relaxation in solids: mechanisms and measuring techniques

    International Nuclear Information System (INIS)

    Bonville, P.

    1983-01-01

    The fluctuations of electronic magnetic moments in solids may be investigated by several techniques, either electronic or nuclear. This paper is an introduction of the most frequently encountered paramagnetic relaxation mechanisms (phonons, conduction electrons, exchange or dipolar interactions) in condensed matter, and to the different techniques used for measuring relaxation frequencies: electronic paramagnetic resonance, nuclear magnetic resonance, Moessbauer spectroscopy, inelastic neutron scattering, measurement of longitudinal ac susceptibility and γ-γ perturbed angular correlations. We mainly focus our attention on individual ionic fluctuation spectra, the majority of the experimental work refered to concerning rare earth systems [fr

  19. Measurement of gravity and gauge fields using quantum mechanical probes

    International Nuclear Information System (INIS)

    Anandan, J.

    1986-01-01

    The author considers the question of which quantities are observed when the gravitational and gauge fields are measured by a quantum mechanical probe. The motion of a quantum mechanical particle can be constructed, via Huyghens' principle, by the interference of secondary wavelets. Three types of interference phenomena are considered: interference of two coherent beams separated in space-time during part of their motion; interference of two coherent beams which are in the same region in spacetime but differ in energy or mass; and the Josphson effect and its generalization. The author shows how to determine the gravitational field by means of quantum interference. The corresponding problem for gauge fields is treated and a simple proof of the previously proved theorem for the reconstruction of the connection from the holonomy transformations is presented. A heuristic principle for the gravitational interaction of two quantum mechanical particles is formulated which implies the equivalence of inertial and active gravitational masses

  20. A high accuracy algorithm of displacement measurement for a micro-positioning stage

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2017-05-01

    Full Text Available A high accuracy displacement measurement algorithm for a two degrees of freedom compliant precision micro-positioning stage is proposed based on the computer micro-vision technique. The algorithm consists of an integer-pixel and a subpixel matching procedure. Series of simulations are conducted to verify the proposed method. The results show that the proposed algorithm possesses the advantages of high precision and stability, the resolution can attain to 0.01 pixel theoretically. In addition, the consuming time is reduced about 6.7 times compared with the classical normalized cross correlation algorithm. To validate the practical performance of the proposed algorithm, a laser interferometer measurement system (LIMS is built up. The experimental results demonstrate that the algorithm has better adaptability than that of the LIMS.

  1. A micromachined membrane-based active probe for biomolecular mechanics measurement

    Science.gov (United States)

    Torun, H.; Sutanto, J.; Sarangapani, K. K.; Joseph, P.; Degertekin, F. L.; Zhu, C.

    2007-04-01

    A novel micromachined, membrane-based probe has been developed and fabricated as assays to enable parallel measurements. Each probe in the array can be individually actuated, and the membrane displacement can be measured with high resolution using an integrated diffraction-based optical interferometer. To illustrate its application in single-molecule mechanics experiments, this membrane probe was used to measure unbinding forces between L-selectin reconstituted in a polymer-cushioned lipid bilayer on the probe membrane and an antibody adsorbed on an atomic force microscope cantilever. Piconewton range forces between single pairs of interacting molecules were measured from the cantilever bending while using the membrane probe as an actuator. The integrated diffraction-based optical interferometer of the probe was demonstrated to have floor for frequencies as low as 3 Hz with a differential readout scheme. With soft probe membranes, this low noise level would be suitable for direct force measurements without the need for a cantilever. Furthermore, the probe membranes were shown to have 0.5 µm actuation range with a flat response up to 100 kHz, enabling measurements at fast speeds.

  2. Body position-dependent shift in odor percept present only for perithreshold odors.

    Science.gov (United States)

    Lundström, Johan N; Boyle, Julie A; Jones-Gotman, Marilyn

    2008-01-01

    We recently demonstrated that a supine position causes a decrease in olfactory sensitivity compared with an upright position. We pursued that initial finding in 3 separate experiments in which we explored the extent of, and mechanism underlying, this phenomenon. In Experiment 1, we replicated the decrease in olfactory sensitivity when in a supine compared with an upright position. In Experiment 2, we measured body position-dependent shifts in physiological variables and sniff measures while smelling suprathreshold odorants and performing a perithreshold odor intensity discrimination task. Olfactory performances were reduced while supine. However, no relationships between the shift in olfactory performances and either the physiological variables or sniff measures were found. In Experiment 3, we determined that there were no position-dependent shifts in ability to discriminate or identify suprathreshold odors or rate them for pleasantness, intensity, or familiarity. However, a drop in scores was observed, and performance was slowed, on a cognitive skill while supine. These results demonstrate a body position-dependent shift in olfactory sensitivity only for perithreshold odors that appears to be mediated by cognitive rather than physiological factors. Implications for olfactory imaging studies are discussed.

  3. Automated translating beam profiler for in situ laser beam spot-size and focal position measurements

    Science.gov (United States)

    Keaveney, James

    2018-03-01

    We present a simple and convenient, high-resolution solution for automated laser-beam profiling with axial translation. The device is based on a Raspberry Pi computer, Pi Noir CMOS camera, stepper motor, and commercial translation stage. We also provide software to run the device. The CMOS sensor is sensitive over a large wavelength range between 300 and 1100 nm and can be translated over 25 mm along the beam axis. The sensor head can be reversed without changing its axial position, allowing for a quantitative estimate of beam overlap with counter-propagating laser beams. Although not limited to this application, the intended use for this device is the automated measurement of the focal position and spot-size of a Gaussian laser beam. We present example data of one such measurement to illustrate device performance.

  4. Superharp: A wire scanner with absolute position readout for beam energy measurement at CEBAF

    International Nuclear Information System (INIS)

    Yan, C.

    1994-01-01

    Superharp is an upgrade CEBAF wire scanner with absolute position readout from shaft encoder. As high precision absolute beam position probe (Δx ∼ 10μm), three pairs of superharps are installed at the entrance, the mid-point, and the exit of Hall C arc beamline in beam switch yard, which will be tuned in dispersive mode as energy spectrometer performing 10 -3 beam energy measurement. With dual sensor system: the direct current pickup and the bremsstrahlung detection electronics, beam profile can be obtained by superharp at wide beam current range from 1 μA to 100 μA

  5. Scapular positioning and motor control in children and adults: a laboratory study using clinical measures.

    Science.gov (United States)

    Struyf, Filip; Nijs, Jo; Horsten, Stijn; Mottram, Sarah; Truijen, Steven; Meeusen, Romain

    2011-04-01

    The scapular muscular system is the major determinant of scapular positioning. In addition, strength and muscular endurance develops from childhood through adolescence. It is not known whether differences in scapular positioning and motor control between adults and children may exist. Ninety-two shoulders of 46 adults (mean = 39.4; 18-86 years; SD = 22.5), and 116 shoulders of 59 children (mean = 11.6; 6-17 years; SD = 3.5), were included in the study. Scapular positioning data were collected using a clinical assessment protocol including visual observation of titling and winging, measurement of forward shoulder posture, measurement of scapular upward rotation, and the Kinetic Medial Rotation Test (KMRT). The observation protocol for scapular winging and tilting did not show significant differences between adults and children. After controlling for height, forward shoulder posture (relaxed (0.28 cm/cm (0.06) vs. 0.31 cm/cm (0.07) and retracted (0.15 cm/cm (0.05) vs. 0.20 cm/cm (0.06)) were significantly smaller in children than in adults (P < 0.01). In addition, children showed greater scapular upward rotation (18.6°; SD 9.6°) than adults (14.5°; SD 10.9°) at 90° shoulder abduction. No significant differences were seen between children (19% positive test) and adults (24% positive test) using the KMRT. Children and adults show significant but small differences in scapular upward rotation and forward shoulder posture. These data provide useful reference values using a clinical protocol. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  7. Particle Filter Based Fault-tolerant ROV Navigation using Hydro-acoustic Position and Doppler Velocity Measurements

    DEFF Research Database (Denmark)

    Zhao, Bo; Blanke, Mogens; Skjetne, Roger

    2012-01-01

    This paper presents a fault tolerant navigation system for a remotely operated vehicle (ROV). The navigation system uses hydro-acoustic position reference (HPR) and Doppler velocity log (DVL) measurements to achieve an integrated navigation. The fault tolerant functionality is based on a modied...... particle lter. This particle lter is able to run in an asynchronous manner to accommodate the measurement drop out problem, and it overcomes the measurement outliers by switching observation models. Simulations with experimental data show that this fault tolerant navigation system can accurately estimate...

  8. Using a smartphone as a tool to measure compensatory and anomalous head positions.

    Science.gov (United States)

    Farah, Michelle de Lima; Santinello, Murillo; Carvalho, Luis Eduardo Morato Rebouças de; Uesugui, Carlos Fumiaki; Barcellos, Ronaldo Boaventura

    2018-01-01

    To describe a new method for measuring anomalous head positions by using a cell phone. The photo rotation feature of the iPhone® PHOTOS application was used. With the patient seated on a chair, a horizontal stripe was fixed on the wall in the background and a sagittal stripe was fixed on the seat. Photographs were obtained in the following views: front view (photographs A and B; with the head tilted over one shoulder) and upper axial view (photographs C and D; viewing the forehead and nose) (A and C are without camera rotation, and B and D are with camera rotation). A blank sheet of paper with two straight lines making a 32-degree angle was also photographed. Thirty examiners were instructed to measure the rotation required to align the reference points with the orthogonal axes. In order to set benchmarks to be compared with the measurements obtained by the examiners, blue lines were digitally added to the front and upper view photographs. In the photograph of the sheet of paper (p=0.380 and a=5%), the observed values did not differ statistically from the known value of 32 degrees. Mean measurements were as follows: front view photograph A, 22.8 ± 2.77; front view B, 21.4 ± 1.61; upper view C, 19.6 ± 2.36; and upper view D, 20.1 ± 2.33 degrees. The mean difference in measurements for the front view photograph A was -1.88 (95% CI -2.88 to -0.88), front view B was -0.37 (95% CI -0.97 to 0.17), upper view C was 1.43 (95% CI 0.55 to 2.24), and upper view D was 1.87 (95% CI 1.02 to 2.77). The method used in this study for measuring anomalous head position is reproducible, with maximum variations for AHPs of 2.88 degrees around the X-axis and 2.77 degrees around the Y-axis.

  9. Using a smartphone as a tool to measure compensatory and anomalous head positions

    Directory of Open Access Journals (Sweden)

    Michelle de Lima Farah

    Full Text Available ABSTRACT Purpose: To describe a new method for measuring anomalous head positions by using a cell phone. Methods: The photo rotation feature of the iPhone® PHOTOS application was used. With the patient seated on a chair, a horizontal stripe was fixed on the wall in the background and a sagittal stripe was fixed on the seat. Photographs were obtained in the following views: front view (photographs A and B; with the head tilted over one shoulder and upper axial view (photographs C and D; viewing the forehead and nose (A and C are without camera rotation, and B and D are with camera rotation. A blank sheet of paper with two straight lines making a 32-degree angle was also photographed. Thirty examiners were instructed to measure the rotation required to align the reference points with the orthogonal axes. In order to set benchmarks to be compared with the measurements obtained by the examiners, blue lines were digitally added to the front and upper view photographs. Results: In the photograph of the sheet of paper (p=0.380 and a=5%, the observed values did not differ statistically from the known value of 32 degrees. Mean measurements were as follows: front view photograph A, 22.8 ± 2.77; front view B, 21.4 ± 1.61; upper view C, 19.6 ± 2.36; and upper view D, 20.1 ± 2.33 degrees. The mean difference in measurements for the front view photograph A was -1.88 (95% CI -2.88 to -0.88, front view B was -0.37 (95% CI -0.97 to 0.17, upper view C was 1.43 (95% CI 0.55 to 2.24, and upper view D was 1.87 (95% CI 1.02 to 2.77. Conclusion: The method used in this study for measuring anomalous head position is reproducible, with maximum variations for AHPs of 2.88 degrees around the X-axis and 2.77 degrees around the Y-axis.

  10. [Effect of 45 degree angle semirecumbent position on ventilator-associated pneumonia in mechanical ventilated patients: a meta-analysis].

    Science.gov (United States)

    Leng, Yu-xin; Song, Ya-han; Yao, Zhi-yuan; Zhu, Xi

    2012-10-01

    To systemically analyze the effect of 45 degree angle semirecumbent position on the incidence of ventilator-associated pneumonia (VAP) and other outcomes in mechanical ventilated patients, and to evaluate whether 45 degree angle semirecumbent position is superior to 25 degree angle-30 degree angle head of bed (HOB). The randomized controlled trials (RCTs) comparing the effect of different HOB on the outcomes of mechanical ventilated patients were searched (from 1st January 1990 to 20th July 2012) from five databases including the Cochrane Central Register of Controlled Trials, MEDLINE, Embase, China Knowledge Resource Integrated Database (CNKI), and Wanfang Database. Meta analysis was conducted using RevMan 5.0 software. Data extracted from five RCTs with a total of 427 patients were analyzed. The risks of developing clinically diagnosed VAP were significantly lower among the patients in semirecumbent 45 degree angle position compared to the patients in lower position [15.96% (34/213) vs. 26.64% (57/214), relative risk (RR)=0.57, 95% confidence interval (95%CI) 0.39 to 0.83, P=0.003], while no significant differences were detected between the two groups regarding the mortality rate [27.04% (53/196) vs. 28.22% (57/202), RR=0.93, 95%CI 0.68 to 1.27, P=0.66], the length of intensive care unit (ICU) stay [weighted mean difference (WMD)=-0.45, 95%CI -1.08 to 0.18, P=0.16] and the percentage of antibiotics treatment [71.11% (32/45) vs. 60.87% (28/46), RR=1.14, 95%CI 0.85 to 1.53, P=0.37]. Two of the five trials (91 patients) were included in the sub-analysis between 45 degree angle group (45 patients) and 25 degree angle-30 degree angle group (46 patients). The results showed that comparing with 25 degree angle-30 degree angle, 45 degree angle semirecumbent position had no significance in improving patients' clinical outcomes. This study proved that the clinically preferred semirecumbent 45 degree angle position did have effect in reducing the incidence of VAP

  11. In situ mechanical TEM: seeing and measuring under stress with electrons

    International Nuclear Information System (INIS)

    Legros, M.

    2014-01-01

    From the first observation of moving dislocations in 1956 to the latest developments of piezo-actuated sample holders and direct electron sensing cameras in modern transmission electron microscopes (TEM), in situ mechanical testing has brought an unequaled view of the involved mechanisms during the plastic deformation of materials. Although MEMS-based or load-cell equipped holders provide an almost direct measure of these quantities, deriving stress and strain from in situ TEM experiments has an extensive history. Nowadays, the realization of a complete mechanical test while observing the evolution of a dislocation structure is possible, and it constitutes the perfect combination to explore size effects in plasticity. New cameras, data acquisition rates and intrinsic image-related techniques, such as holography, should extend the efficiency and capabilities of in situ deformation inside a TEM. (author)

  12. A novel mechatronic system for measuring end-point stiffness: mechanical design and preliminary tests.

    Science.gov (United States)

    Masia, L; Sandini, G; Morasso, P G

    2011-01-01

    Measuring arm stiffness is of great interest for many disciplines from biomechanics to medicine especially because modulation of impedance represents one of the main mechanism underlying control of movement and interaction with external environment. Previous works have proposed different methods to identify multijoint hand stiffness by using planar or even tridimensional haptic devices, but the associated computational burden makes them not easy to implement. We present a novel mechanism conceived for measuring multijoint planar stiffness by a single measurement and in a reduced execution time. A novel mechanical rotary device applies cyclic radial perturbation to human arm of a known displacement and the force is acquired by means of a 6-axes commercial load cell. The outcomes suggest that the system is not only reliable but allows obtaining a bi-dimensional estimation of arm stiffness in reduced amount of time and the results are comparable with those reported in previous researches. © 2011 IEEE

  13. Note of positions of particles in classical relativistic mechanics

    International Nuclear Information System (INIS)

    Pazma, V.

    1983-01-01

    The relation between world-lines and the position vector of a particle is studied from the point of view of gauge system theory. The expressions for the position vector of a free relativistic particle and of two interacting particles described by the Todorov-Komar model are derived under plausible assumptions. The relation between the physical meaning of basic canonical variables and the choice of a gauge is also discussed. (author)

  14. Performance Analysis and Design Strategy for a Second-Order, Fixed-Gain, Position-Velocity-Measured (α-β-η-θ Tracking Filter

    Directory of Open Access Journals (Sweden)

    Kenshi Saho

    2017-07-01

    Full Text Available We present a strategy for designing an α - β - η - θ filter, a fixed-gain moving-object tracking filter using position and velocity measurements. First, performance indices and stability conditions for the filter are analytically derived. Then, an optimal gain design strategy using these results is proposed and its relationship to the position-velocity-measured (PVM Kalman filter is shown. Numerical analyses demonstrate the effectiveness of the proposed strategy, as well as a performance improvement over the traditional position-only-measured α - β filter. Moreover, we apply an α - β - η - θ filter designed using this strategy to ultra-wideband Doppler radar tracking in numerical simulations. We verify that the proposed strategy can easily design the gains for an α - β - η - θ filter based on the performance of the ultra-wideband Doppler radar and a rough approximation of the target’s acceleration. Moreover, its effectiveness in predicting the steady state performance in designing the position-velocity-measured Kalman filter is also demonstrated.

  15. High-resolution optical polarimetric elastography for measuring the mechanical properties of tissue

    Science.gov (United States)

    Hudnut, Alexa W.; Armani, Andrea M.

    2018-02-01

    Traditionally, chemical and molecular markers have been the predominate method in diagnostics. Recently, alternate methods of determining tissue and disease characteristics have been proposed based on testing the mechanical behavior of biomaterials. Existing methods for performing elastography measurements, such as atomic force microscopy, compression testing, and ultrasound elastography, require either extensive sample processing or have poor resolution. In the present work, we demonstrate an optical polarimetric elastography device to characterize the mechanical properties of salmon skeletal muscle. A fiber-coupled 1550nm laser paired with an optical polarizer is used to create a fiber optic sensing region. By measuring the change in polarization from the initial state to the final state within the fiber sensing region with a polarimeter, the loading-unloading curves can be determined for the biomaterial. The device is used to characterize the difference between samples with a range of collagen membranes. The loading-unloading curves are used to determine the change in polarization phase and energy loss of the samples at 10%, 20% and 30% strain. As expected, the energy loss is a better metric for measuring the mechanical properties of the tissues because it incorporates the entire loading-unloading curve rather than a single point. Using this metric, it is demonstrated the device can repeatedly differentiate between the different membrane configurations.

  16. Validity of an ankle joint motion and position sense measurement system and its application in healthy subjects and patients with ankle sprain.

    Science.gov (United States)

    Lin, Chueh-Ho; Chiang, Shang-Lin; Lu, Liang-Hsuan; Wei, Shun-Hwa; Sung, Wen-Hsu

    2016-07-01

    Ankle motion and proprioception in multiple axis movements are crucial for daily activities. However, few studies have developed and used a multiple axis system for measuring ankle motion and proprioception. This study was designed to validate a novel ankle haptic interface system that measures the ankle range of motion (ROM) and joint position sense in multiple plane movements, investigating the proprioception deficits during joint position sense tasks for patients with ankle instability. Eleven healthy adults (mean ± standard deviation; age, 24.7 ± 1.9 years) and thirteen patients with ankle instability were recruited in this study. All subjects were asked to perform tests to evaluate the validity of the ankle ROM measurements and underwent tests for validating the joint position sense measurements conducted during multiple axis movements of the ankle joint. Pearson correlation was used for validating the angular position measurements obtained using the developed system; the independent t test was used to investigate the differences in joint position sense task performance for people with or without ankle instability. The ROM measurements of the device were linearly correlated with the criterion standards (r = 0.99). The ankle instability and healthy groups were significantly different in direction, absolute, and variable errors of plantar flexion, dorsiflexion, inversion, and eversion (p ankle joint motion and position sense measurement system is valid and can be used for measuring the ankle ROM and joint position sense in multiple planes and indicate proprioception deficits for people with ankle instability. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Positive and negative streamers in ambient air: measuring diameter, velocity and dissipated energy

    Energy Technology Data Exchange (ETDEWEB)

    Briels, T M P; Kos, J; Van Veldhuizen, E M; Ebert, U [Department of Applied Physics, Technische Universiteit Eindhoven, PO Box 513, 5600 MB Eindhoven (Netherlands); Winands, G J J [Department of Electrical Engineering, Technische Universiteit Eindhoven, PO Box 513, 5600 MB Eindhoven (Netherlands)], E-mail: e.m.v.veldhuizen@tue.nl, E-mail: ebert@cwi.nl

    2008-12-07

    Positive and negative streamers are studied in ambient air at 1 bar; they emerge from a needle electrode placed 40 mm above a planar electrode. The amplitudes of the applied voltage pulses range from 5 to 96 kV; most pulses have rise times of 30 ns or shorter. Diameters, velocities and energies of the streamers are measured. Two regimes are identified; a low voltage regime where only positive streamers appear and a high voltage regime where both positive and negative streamers exist. Below 5 kV, no streamers emerge. In the range from 5 to 40 kV, positive streamers form, while the negative discharges only form a glowing cloud at the electrode tip, but no streamers. For 5-20 kV, diameters and velocities of the positive streamers have the minimal values of d = 0.2 mm and v {approx} 10{sup 5} m s{sup -1}. For 20-40 kV, their diameters increase by a factor of 6 while the voltage increases only by a factor of 2. Above the transition value of 40 kV, streamers of both polarities form; they strongly resemble each other, though the positive ones propagate further; their diameters continue to increase with applied voltage. For 96 kV, positive streamers attain diameters of 3 mm and velocities of 4 x 10{sup 6} m s{sup -1}; negative streamers are about 20% slower and thinner. An empirical fit formula for the relation between velocity v and diameter d is v = 0.5d{sup 2} mm{sup -1} ns{sup -1} for both polarities. Streamers of both polarities dissipate energies of the order of several millijoules per streamer while crossing the gap.

  18. Accurate position estimation methods based on electrical impedance tomography measurements

    Science.gov (United States)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    than 0.05% of the tomograph radius value. These results demonstrate that the proposed approaches can estimate an object’s position accurately based on EIT measurements if enough process information is available for training or modelling. Since they do not require complex calculations it is possible to use them in real-time applications without requiring high-performance computers.

  19. Implementation of electron beam position measurement algorithm and embedded web server using MCS-51 microcontroller for Booster Synchrotron

    International Nuclear Information System (INIS)

    Shrivastava, B.B.; Chouhan, Manish; Puntambekar, T.A.; Tiwari, A.N.

    2015-01-01

    The Booster Synchrotron at RRCAT caters as Injector Machine for Indus-1 and Indus-2 with the repetition rate of 1Hz. In Booster Synchrotron, energy of electron bunches are increased from 20 MeV to 450 MeV (in ∼ 280 ms) and 550 MeV (in ∼ 340 ms ) for Indus-1 and Indus-2 respectively. An algorithm for microcontroller based beam position measurement system has been developed for the Booster Synchrotron to measure the fast changes in the beam position of electron bunches during energy ramping. In this paper, software implementation in microcontroller and its optimization to achieve beam position update rate of 1 kHz is discussed. (author)

  20. Measures for Administration of the Import of Mechanical and Electronic Products

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ The Measures for the Administration of the Import of Mechanical and Electronic Products co-formulated by the Ministry of Commerce,the General Administration of Customs and the General Administration of Quality Supervision,Inspection and Quarantine,was hereby promul-gated,which entered into force as of May 1,2008.

  1. Positioning accuracy analysis of adjusting target mechanism of three-dimensional attitude

    International Nuclear Information System (INIS)

    Ma Li; Wang Kun; Sun Linzhi; Zhou Shasha

    2012-01-01

    A novel adjusting target mechanism of three-dimensional attitude is presented according to the characteristics of the target transport subsystem in inertial confinement fusion (ICF). The mechanism consists of a tangent mechanism adjusting rotation angle and a set of orthogonal tangent mechanism adjusting two-dimensional deflection angles. The structural parameters of the adjusting target mechanism are analyzed according to principle errors, structure errors and motion errors of following. The analysis results indicate that the system error of the adjusting target mechanism is influenced by the displacement of the linear actuators, the actuator ball radius, the working radius of the tangent mechanism, the angle error of the inclined installation hole, the centralization error of the actuators, the orthogonal error of the two tangent mechanism, and the angle errors of the inclined target rod inclined rotation shaft. The errors of the inclined target rod and inclined rotation shaft are the two greatest impact factors, the spherical contact error is the next. By means of precise assembly and control system compensation, the accuracy of the adjusting target mechanism can be less than 0.1 mrad. (authors)

  2. Some experimental considerations regarding ion beam simulation of neutron irradiation for mechanical property measurements

    International Nuclear Information System (INIS)

    Styris, D.L.; Jones, R.H.; Harling, O.K.; Kulcinski, G.L.; Marshall, R.P.

    1975-01-01

    A preliminary assessment of the requirements for mechanical property data related to CTR materials is given. The status of ion simulation for mechanical property measurements is described. A damage analysis and calculations for light ions are presented along with sample size, heating and cooling, and surface considerations

  3. Ac-loss measurement of coated conductors: The influence of the pick-up coil position

    International Nuclear Information System (INIS)

    Schmidt, Curt

    2008-01-01

    The ac-loss measurement by the magnetization method requires calibration for obtaining absolute values. A convenient way of calibration is the calorimetric measurement which yields, within the measuring accuracy, absolute loss values. In the magnetization measurement the hysteresis loop of sample magnetization which determines the losses is measured via the integration of magnetic flux penetrating a pick-up coil. The ratio of flux integral to magnetization integral and hence the calibration factor is however, for a given pick-up coil geometry, not exactly a constant, but depends on the magnetization current pattern within the sample. Especially for thin tapes in perpendicular external field this effect has to be taken into consideration in order to avoid miss measurements. The relation between measured flux and sample magnetization was calculated for special cases of magnetization current distribution in the sample as a function of the pick-up coil position. Furthermore calibration factors were measured as a function of the ac-field amplitude and the result compared with available theoretical models. A good agreement was found between experiment and theory

  4. Respiratory mechanics to understand ARDS and guide mechanical ventilation.

    Science.gov (United States)

    Mauri, Tommaso; Lazzeri, Marta; Bellani, Giacomo; Zanella, Alberto; Grasselli, Giacomo

    2017-11-30

    As precision medicine is becoming a standard of care in selecting tailored rather than average treatments, physiological measurements might represent the first step in applying personalized therapy in the intensive care unit (ICU). A systematic assessment of respiratory mechanics in patients with the acute respiratory distress syndrome (ARDS) could represent a step in this direction, for two main reasons. Approach and Main results: On the one hand, respiratory mechanics are a powerful physiological method to understand the severity of this syndrome in each single patient. Decreased respiratory system compliance, for example, is associated with low end expiratory lung volume and more severe lung injury. On the other hand, respiratory mechanics might guide protective mechanical ventilation settings. Improved gravitationally dependent regional lung compliance could support the selection of positive end-expiratory pressure and maximize alveolar recruitment. Moreover, the association between driving airway pressure and mortality in ARDS patients potentially underlines the importance of sizing tidal volume on respiratory system compliance rather than on predicted body weight. The present review article aims to describe the main alterations of respiratory mechanics in ARDS as a potent bedside tool to understand severity and guide mechanical ventilation settings, thus representing a readily available clinical resource for ICU physicians.

  5. Positive Nonlinear Dynamical Group Uniting Quantum Mechanics and Thermodynamics

    OpenAIRE

    Beretta, Gian Paolo

    2006-01-01

    We discuss and motivate the form of the generator of a nonlinear quantum dynamical group 'designed' so as to accomplish a unification of quantum mechanics (QM) and thermodynamics. We call this nonrelativistic theory Quantum Thermodynamics (QT). Its conceptual foundations differ from those of (von Neumann) quantum statistical mechanics (QSM) and (Jaynes) quantum information theory (QIT), but for thermodynamic equilibrium (TE) states it reduces to the same mathematics, and for zero entropy stat...

  6. Quantum mechanics and stochastic mechanics for compatible observables at different times

    International Nuclear Information System (INIS)

    Correggi, M.; Morchio, G.

    2002-01-01

    Bohm mechanics and Nelson stochastic mechanics are confronted with quantum mechanics in the presence of noninteracting subsystems. In both cases, it is shown that correlations at different times of compatible position observables on stationary states agree with quantum mechanics only in the case of product wave functions. By appropriate Bell-like inequalities it is shown that no classical theory, in particular no stochastic process, can reproduce the quantum mechanical correlations of position variables of noninteracting systems at different times

  7. Quantum back-action-evading measurement of motion in a negative mass reference frame

    Science.gov (United States)

    Møller, Christoffer B.; Thomas, Rodrigo A.; Vasilakis, Georgios; Zeuthen, Emil; Tsaturyan, Yeghishe; Balabas, Mikhail; Jensen, Kasper; Schliesser, Albert; Hammerer, Klemens; Polzik, Eugene S.

    2017-07-01

    Quantum mechanics dictates that a continuous measurement of the position of an object imposes a random quantum back-action (QBA) perturbation on its momentum. This randomness translates with time into position uncertainty, thus leading to the well known uncertainty on the measurement of motion. As a consequence of this randomness, and in accordance with the Heisenberg uncertainty principle, the QBA puts a limitation—the so-called standard quantum limit—on the precision of sensing of position, velocity and acceleration. Here we show that QBA on a macroscopic mechanical oscillator can be evaded if the measurement of motion is conducted in the reference frame of an atomic spin oscillator. The collective quantum measurement on this hybrid system of two distant and disparate oscillators is performed with light. The mechanical oscillator is a vibrational ‘drum’ mode of a millimetre-sized dielectric membrane, and the spin oscillator is an atomic ensemble in a magnetic field. The spin oriented along the field corresponds to an energetically inverted spin population and realizes a negative-effective-mass oscillator, while the opposite orientation corresponds to an oscillator with positive effective mass. The QBA is suppressed by -1.8 decibels in the negative-mass setting and enhanced by 2.4 decibels in the positive-mass case. This hybrid quantum system paves the way to entanglement generation and distant quantum communication between mechanical and spin systems and to sensing of force, motion and gravity beyond the standard quantum limit.

  8. Quantum back-action-evading measurement of motion in a negative mass reference frame.

    Science.gov (United States)

    Møller, Christoffer B; Thomas, Rodrigo A; Vasilakis, Georgios; Zeuthen, Emil; Tsaturyan, Yeghishe; Balabas, Mikhail; Jensen, Kasper; Schliesser, Albert; Hammerer, Klemens; Polzik, Eugene S

    2017-07-12

    Quantum mechanics dictates that a continuous measurement of the position of an object imposes a random quantum back-action (QBA) perturbation on its momentum. This randomness translates with time into position uncertainty, thus leading to the well known uncertainty on the measurement of motion. As a consequence of this randomness, and in accordance with the Heisenberg uncertainty principle, the QBA puts a limitation-the so-called standard quantum limit-on the precision of sensing of position, velocity and acceleration. Here we show that QBA on a macroscopic mechanical oscillator can be evaded if the measurement of motion is conducted in the reference frame of an atomic spin oscillator. The collective quantum measurement on this hybrid system of two distant and disparate oscillators is performed with light. The mechanical oscillator is a vibrational 'drum' mode of a millimetre-sized dielectric membrane, and the spin oscillator is an atomic ensemble in a magnetic field. The spin oriented along the field corresponds to an energetically inverted spin population and realizes a negative-effective-mass oscillator, while the opposite orientation corresponds to an oscillator with positive effective mass. The QBA is suppressed by -1.8 decibels in the negative-mass setting and enhanced by 2.4 decibels in the positive-mass case. This hybrid quantum system paves the way to entanglement generation and distant quantum communication between mechanical and spin systems and to sensing of force, motion and gravity beyond the standard quantum limit.

  9. Measuring the correlation between cell mechanics and myofibroblastic differentiation during maturation of 3D microtissues

    Science.gov (United States)

    Zhao, Ruogang; Wang, Weigang; Boudou, Thomas; Chen, Christopher; Reich, Daniel

    2013-03-01

    Tissue stiffness and cellular contractility are two of the most important biomechanical factors regulating pathological transitions of encapsulated cells, such as the differentiation of fibroblasts into myofibroblasts - a key event contributing to tissue fibrosis. However, a quantitative correlation between tissue stiffness and cellular contraction and myofibroblast differentiation has not yet been established in 3D environments, mainly due to the lack of suitable 3D tissue culture models that allow both tissue remodeling and simultaneous measurement of the cell/tissue mechanics. To address this, we have developed a magnetic microtissue tester system that allows the remodeling of arrays of cell-laden 3D collagen microtissues and the measurement of cell and tissue mechanics using magnetically actuated elastomeric microcantilevers. By measuring the development of cell/tissue mechanical properties and the expression level of α-smooth muscle actin (α-SMA, a marker for myofibroblast differentiation) during a 6 day culture period, we found microtissue stiffness increased by 45% and α-SMA expression increased by 38%, but tissue contraction forces only increased by 10%, indicating that tissue stiffness may be the predominant mechanical factor for regulation of myofibroblast differentiation. This study provides new quantitative insight into the regulatory effect of cell and tissue mechanics on cellular function. Supported in part by NIH grant HL090747

  10. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    CERN Document Server

    Murazaki, M; Uno, Y

    2003-01-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of +-13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, alpha, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and sup 3 He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, ...

  11. A laser optical torquemeter for measuring the mechanical power furnished by a chirale turbine

    Science.gov (United States)

    Bonfanti, Marco; La Rosa, Guido; Lo Savio, Fabio

    2005-02-01

    The design of the present laser optical torquemeter arose from the need to measure the mechanical power furnished by a prototype of chirale turbine, which exploits the lift force produced in the rotor, due to the "Magnus effect." The particular optical reading system allows the device to determine both the torque and the mechanical power. The torque value is obtained through the reading of the torsional angle. From this value, together with that of the transmission shaft angular speed measured by the same torquemeter, the mechanical power of the turbine is calculated. The optical system output signals are acquired, processed and elaborated by a virtual logic circuit, simulated by means of a suitable home-made software in LabVIEW environment. The torquemeter has been tested operating with the prototype of turbine in a wind tunnel.

  12. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    Directory of Open Access Journals (Sweden)

    Dongkai Shen

    2016-01-01

    Full Text Available In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.

  13. Contact-type displacement measuring mechanism for fuel assembly in reactor

    International Nuclear Information System (INIS)

    Yokota, Yoshio; Ko, Kuniaki.

    1995-01-01

    The measuring mechanism of the present invention, which is used in a lmfbr type reactor, is suspended by a gripper of a fuel handing machine, and it comprises a combination of a displacement amount measuring jig allowed to be inserted into a handling head of a fuel assembly and a displacement amount measuring ring disposed at the lower portion in the handling head. The displacement amount measuring jig has a structure comprising a releasable handle and a columnar or cylindrical measuring portion allowable to be inserted into the handling head formed at the lower portion of the handle, which are connected with each other. When an interference (contact) occurred between the displacement amount measuring jig and the stepwise displacement amount measuring ring during the measurement, change of load and a phenomenon that the fuel handing machine can not be lowered are recognized, so that core displacement amount can be recognized based on the stroke of the gripper portion. Then, remote measurement is possible for displacement and deformation of the fuel assembly in the reactor container, and the measurement can be conducted by the same procedures and in the same period of time as in a case of ordinary fuel exchange operation. A flow channel for coolants passing through the fuel assembly can be ensured, thereby enabling to measure the amount of core displacement which is closer to an actual value in the reactor. (N.H.)

  14. Positive psychology outcome measures for family caregivers of people living with dementia: a systematic review

    NARCIS (Netherlands)

    Stansfeld, J.; Stoner, C.R.; Wenborn, J.; Vernooij-Dassen, M.J.F.J.; Moniz-Cook, E.; Orrell, M.

    2017-01-01

    BACKGROUND: Family caregivers of people living with dementia can have both positive and negative experiences of caregiving. Despite this, existing outcome measures predominately focus on negative aspects of caregiving such as burden and depression. This review aimed to evaluate the development and

  15. The Antikythera Mechanism: The oldest mechanical universe in its scientific milieu

    Science.gov (United States)

    Moussas, Xenophon

    2011-06-01

    four-year dial shows the year of all Greek Festivities, the so-called `games' (Olympic, Pythian, Isthmian etc). Two additional dials give the Exeligmos, the 54 year and 34 day cycle, which provides a more accurate prediction of eclipses. It is possible that the Mechanism was also equipped with a planetary show display, as three of the planets and their motion (stationary points) are mentioned many times in the manual of the instrument, so it was also a planetarium. From the manual we have hints that the mechanism was probably also an observational instrument, as having instructions concerning a viewfinder and possibly how to orient the viewfinder to pass a sunbeam through it, probably measuring the altitude of the Sun. There are fragmented sentences that probably give instructions on how to move the pointers to set the position of the Sun, the Moon and the planets in their initial places in the ecliptic, on a specific day, or how to measure angular distances between two celestial bodies or their coordinates. This mechanism is definitely not the first one of its kind. The fact that it is accompanied with instructions means that the constructor had in its mind to be used by somebody else and one posits that he made at least another similar instrument.

  16. Stringent Nucleotide Recognition by the Ribosome at the Middle Codon Position.

    Science.gov (United States)

    Liu, Wei; Shin, Dongwon; Ng, Martin; Sanbonmatsu, Karissa Y; Tor, Yitzhak; Cooperman, Barry S

    2017-08-29

    Accurate translation of the genetic code depends on mRNA:tRNA codon:anticodon base pairing. Here we exploit an emissive, isosteric adenosine surrogate that allows direct measurement of the kinetics of codon:anticodon University of California base formation during protein synthesis. Our results suggest that codon:anticodon base pairing is subject to tighter constraints at the middle position than at the 5'- and 3'-positions, and further suggest a sequential mechanism of formation of the three base pairs in the codon:anticodon helix.

  17. [A project to reduce the incidence of facial pressure ulcers caused by prolonged surgery with prone positioning].

    Science.gov (United States)

    Lee, Wen-Yi; Lin, Pao-Chen; Weng, Chia-Hsing; Lin, Yi-Lin; Tsai, Wen-Lin

    2012-06-01

    We observed in our institute a 13.6% incidence of prolonged surgery (>4 hours) induced facial pressure ulcers that required prone positioning. Causes identified included: (1) customized silicon face pillows used were not suited for every patient; (2) our institute lacked a standard operating procedure for prone positioning; (3) our institute lacked a postoperative evaluation and audit procedure for facial pressure ulcers. We designed a strategy to reduce post-prolonged surgery facial pressure ulcer incidence requiring prone positioning by 50% (i.e., from 13.6% to 6.8%). We implemented the following: (1) Created a new water pillow to relieve facial pressure; (2) Implemented continuing education pressure ulcer prevention and evaluation; (3) Established protocols on standard care for prone-position patients and proper facial pressure ulcer identification; (4) Established a face pressure ulcers accident reporting mechanism; and (5) Established an audit mechanism facial pressure ulcer cases. After implementing the resolution measures, 116 patients underwent prolonged surgery in a prone position (mean operating time: 298 mins). None suffered from facial pressure ulcers. The measures effectively reduced the incidence of facial pressure ulcers from 13.6% to 0.0%. The project used a water pillow to relieve facial pressure and educated staff to recognize and evaluate pressure ulcers. These measures were demonstrated effective in reducing the incidence of facial pressure ulcers caused by prolonged prone positioning.

  18. An Intelligent Optical Dissolved Oxygen Measurement Method Based on a Fluorescent Quenching Mechanism.

    Science.gov (United States)

    Li, Fengmei; Wei, Yaoguang; Chen, Yingyi; Li, Daoliang; Zhang, Xu

    2015-12-09

    Dissolved oxygen (DO) is a key factor that influences the healthy growth of fishes in aquaculture. The DO content changes with the aquatic environment and should therefore be monitored online. However, traditional measurement methods, such as iodometry and other chemical analysis methods, are not suitable for online monitoring. The Clark method is not stable enough for extended periods of monitoring. To solve these problems, this paper proposes an intelligent DO measurement method based on the fluorescence quenching mechanism. The measurement system is composed of fluorescent quenching detection, signal conditioning, intelligent processing, and power supply modules. The optical probe adopts the fluorescent quenching mechanism to detect the DO content and solves the problem, whereas traditional chemical methods are easily influenced by the environment. The optical probe contains a thermistor and dual excitation sources to isolate visible parasitic light and execute a compensation strategy. The intelligent processing module adopts the IEEE 1451.2 standard and realizes intelligent compensation. Experimental results show that the optical measurement method is stable, accurate, and suitable for online DO monitoring in aquaculture applications.

  19. An Intelligent Optical Dissolved Oxygen Measurement Method Based on a Fluorescent Quenching Mechanism

    Directory of Open Access Journals (Sweden)

    Fengmei Li

    2015-12-01

    Full Text Available Dissolved oxygen (DO is a key factor that influences the healthy growth of fishes in aquaculture. The DO content changes with the aquatic environment and should therefore be monitored online. However, traditional measurement methods, such as iodometry and other chemical analysis methods, are not suitable for online monitoring. The Clark method is not stable enough for extended periods of monitoring. To solve these problems, this paper proposes an intelligent DO measurement method based on the fluorescence quenching mechanism. The measurement system is composed of fluorescent quenching detection, signal conditioning, intelligent processing, and power supply modules. The optical probe adopts the fluorescent quenching mechanism to detect the DO content and solves the problem, whereas traditional chemical methods are easily influenced by the environment. The optical probe contains a thermistor and dual excitation sources to isolate visible parasitic light and execute a compensation strategy. The intelligent processing module adopts the IEEE 1451.2 standard and realizes intelligent compensation. Experimental results show that the optical measurement method is stable, accurate, and suitable for online DO monitoring in aquaculture applications.

  20. Studies of beam position monitor stability

    International Nuclear Information System (INIS)

    Tenenbaum, P.

    1998-05-01

    The authors present the result s from two studies of the time stability between the mechanical center of a beam position monitor and its electrical/electronic center. In the first study, a group of 93 BPM processors was calibrated via Test Pulse Generator once per hour in order to measure the contribution of the readout electronics to offset drifts. In the second study, a triplet of stripline BPMs in the Final Focus Test Beam, separated only by drift spaces, was read out every 6 minutes during 1 week of beam operation. In both cases offset stability was observed to be on the order of microns over time spans ranging from hours to days, although during the beam study much worse performance was also observed. Implications for the beam position monitor system of future linear collider systems are discussed

  1. PRECISE POSITIONING OF UAVS – DEALING WITH CHALLENGING RTK-GPS MEASUREMENT CONDITIONS DURING AUTOMATED UAV FLIGHTS

    Directory of Open Access Journals (Sweden)

    F. Zimmermann

    2017-08-01

    Full Text Available For some years now, UAVs (unmanned aerial vehicles are commonly used for different mobile mapping applications, such as in the fields of surveying, mining or archeology. To improve the efficiency of these applications an automation of the flight as well as the processing of the collected data is currently aimed at. One precondition for an automated mapping with UAVs is that the georeferencing is performed directly with cm-accuracies or better. Usually, a cm-accurate direct positioning of UAVs is based on an onboard multi-sensor system, which consists of an RTK-capable (real-time kinematic GPS (global positioning system receiver and additional sensors (e.g. inertial sensors. In this case, the absolute positioning accuracy essentially depends on the local GPS measurement conditions. Especially during mobile mapping applications in urban areas, these conditions can be very challenging, due to a satellite shadowing, non-line-of sight receptions, signal diffraction or multipath effects. In this paper, two straightforward and easy to implement strategies will be described and analyzed, which improve the direct positioning accuracies for UAV-based mapping and surveying applications under challenging GPS measurement conditions. Based on a 3D model of the surrounding buildings and vegetation in the area of interest, a GPS geometry map is determined, which can be integrated in the flight planning process, to avoid GPS challenging environments as far as possible. If these challenging environments cannot be avoided, the GPS positioning solution is improved by using obstruction adaptive elevation masks, to mitigate systematic GPS errors in the RTK-GPS positioning. Simulations and results of field tests demonstrate the profit of both strategies.

  2. Improving wellbore position accuracy of horizontal wells by using a continuous inclination measurement from a near bit inclination MWD sensor

    Energy Technology Data Exchange (ETDEWEB)

    Berger, P. E.; Sele, R. [Baker Hughes INTEQ (United States)

    1998-12-31

    Wellbore position calculations are typically performed by measuring azimuth and inclination at 10 to 30 meter intervals and using interpolation techniques to determine the borehole position between survey stations. The input parameters are measured depth (MD), azimuth and inclination, where the two parameters are measured with an MWD tool. Output parameters are the geometric coordinates; true value depth (TVD), north and east. By improving the accuracy of the inclination measurement reduces the uncertainty of the calculated TVD value, resulting in increased confidence in wellbore position. Significant improvements in quality control can be achieved by using multiple sensors. This paper describes a set of quality control parameters that can be used to verify individual sensor performance and a method for calculating TVD uncertainty in horizontal wells, using a single sensor or a combination of sensors. 6 refs., 5 figs.

  3. New possibilities in the prevention of eating disorders: The introduction of positive body image measures.

    Science.gov (United States)

    Piran, Niva

    2015-06-01

    Delineating positive psychological processes in inhabiting the body, as well as quantitative measures to assess them, can facilitate progress in the field of prevention of eating disorders by expanding outcome evaluation of prevention interventions, identifying novel mediators of change, and increasing highly needed research into protective factors. Moreover, enhancing positive ways of inhabiting the body may contribute toward the maintenance of gains of prevention interventions. Integrated social etiological models to eating disorders that focus on gender and other social variables, such as the Developmental Theory of Embodiment (Piran & Teall, 2012a), can contribute to positive body image intervention development and research within the prevention field. Using the Developmental Theory of Embodiment as a lens, this article explores whether existing prevention programs (i.e., Cognitive Dissonance and Media Smart) may already work to promote positive body image, and whether prevention programs need to be expanded toward this goal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Murazaki, Minoru; Uno, Yuichi; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of {+-}13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, {alpha}, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and {sup 3}He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, calculated value agreed well with measurement data of PSPC without Cd cover. (author)

  5. Understanding quantum mechanics by measuring the properties of mesoscopic devices

    International Nuclear Information System (INIS)

    Webb, R.

    1993-01-01

    Measurements of the electrical transport and magnetic properties of micron-size scale insulators, metals, semi-metals, and semiconductors at low temperatures have uncovered a wealth of unexpected phenomena. The only way to understand these new properties is by invoking many of the postulates of quantum mechanics. The author has confirmed that the electron acts as a long-range phase-coherent wave and conventional classical forces are not as important as scalar and vector potentials in determining the response of the electron as it moves through its environment. This talk will focus on the measurement of the Aharonov-Bohm self-interference effects, nonlocal transport phenomena, and persistent currents in normal metal ring structures that have been observed in these nanostructures

  6. Long-term neuromuscular training and ankle joint position sense.

    Science.gov (United States)

    Kynsburg, A; Pánics, G; Halasi, T

    2010-06-01

    Preventive effect of proprioceptive training is proven by decreasing injury incidence, but its proprioceptive mechanism is not. Major hypothesis: the training has a positive long-term effect on ankle joint position sense in athletes of a high-risk sport (handball). Ten elite-level female handball-players represented the intervention group (training-group), 10 healthy athletes of other sports formed the control-group. Proprioceptive training was incorporated into the regular training regimen of the training-group. Ankle joint position sense function was measured with the "slope-box" test, first described by Robbins et al. Testing was performed one day before the intervention and 20 months later. Mean absolute estimate errors were processed for statistical analysis. Proprioceptive sensory function improved regarding all four directions with a high significance (pneuromuscular training has improved ankle joint position sense function in the investigated athletes. This joint position sense improvement can be one of the explanations for injury rate reduction effect of neuromuscular training.

  7. Intraocular pressure measurements in relation to head position and through soft contact lenses: comparison of three portable instruments.

    Science.gov (United States)

    Klein, Ainat; Shemesh, Gabi; Loewenstein, Anat; Kurtz, Shimon

    2011-01-01

    to compare the reproducibility of three portable instruments-the Tono-Pen tonometer (Reichert Ophthalmic Instruments, Depew, NY), the Phosphene tonometer (Bausch & Lomb, Rochester, NY), and the TERT (Through Eyelid Russian Tonometer; Rjazan State Instrument Making, Rjazan, Russia)-in the measurement of intraocular pressure (IOP) with and without soft contact lenses and in different head positions. twenty-six eyes of healthy volunteers were examined by the three instruments while the subjects were sitting, recumbent, and hyperextending their heads, and with and without contact lenses. IOP measurements were compared and the effects of head position and presence of contact lenses on the resultant values were analyzed. the average difference between the recumbent and sitting positions was 3.56, 2.68, and 2.62 mm Hg for the Tono-Pen tonometer, Phosphene tonometer, and TERT, respectively. There was an increase of 5.60, 2.78, and 2.63 mm Hg in hyperextension compared to sitting for the Tono-Pen tonometer, Phosphene tonometer, and TERT, respectively. The difference in the IOP values obtained in the presence and absence of therapeutic contact lens for the three instruments in the three positions was between -1.23 and +1.47 mm Hg. IOP measurements of bedridden patients are only slightly higher than those of sitting patients except for the Tono-Pen tonometer in the hyperextension position. The presence of contact lenses does not affect IOP values obtained by the three evaluated instruments.

  8. 2D MEMS scanner integrating a position feedback

    Directory of Open Access Journals (Sweden)

    Lani Sebastien

    2015-01-01

    Full Text Available An integrated position sensor for a dual-axis electromagnetic tilting mirror is presented. This tilting mirror is composed of a silicon based mirror directly assembled on a silicon membrane supported by flexible beams. The position sensors are constituted by 4 Wheatstone bridges of piezoresistors which are fabricated by doping locally the flexible beams. A permanent magnet is attached to the membrane and the scanner is mounted above planar coils deposited on a ceramic substrate to achieve electromagnetic actuation. The performances of the piezoresistive sensors are evaluated by measuring the output signal of the piezoresistors as a function of the tilt of the mirror and the temperature. White light interferometry was performed for all measurement to measure the exact tilt angle. The minimum detectable angle with such sensors was 30μrad (around 13bits in the range of the minimum resolution of the interferometer. The tilt reproducibility was 0.0186%, obtained by measuring the tilt after repeated actuations with a coil current of 50mA during 30 min and the stability over time was 0.05% in 1h without actuation. The maximum measured tilt angle was 6° (mechanical limited by nonlinearity of the MEMS system.

  9. Mechanical Strain Measurement from Coda Wave Interferometry

    Science.gov (United States)

    Azzola, J.; Schmittbuhl, J.; Zigone, D.; Masson, F.; Magnenet, V.

    2017-12-01

    Coda Wave Interferometry (CWI) aims at tracking small changes in solid materials like rocks where elastic waves are diffusing. They are intensively sampling the medium, making the technique much more sensitive than those relying on direct wave arrivals. Application of CWI to ambient seismic noise has found a large range of applications over the past years like for multiscale imaging but also for monitoring complex structures such as regional faults or reservoirs (Lehujeur et al., 2015). Physically, observed changes are typically interpreted as small variations of seismic velocities. However, this interpretation remains questionable. Here, a specific focus is put on the influence of the elastic deformation of the medium on CWI measurements. The goal of the present work is to show from a direct numerical and experimental modeling that deformation signal also exists in CWI measurements which might provide new outcomes for the technique.For this purpose, we model seismic wave propagation within a diffusive medium using a spectral element approach (SPECFEM2D) during an elastic deformation of the medium. The mechanical behavior is obtained from a finite element approach (Code ASTER) keeping the mesh grid of the sample constant during the whole procedure to limit numerical artifacts. The CWI of the late wave arrivals in the synthetic seismograms is performed using both a stretching technique in the time domain and a frequency cross-correlation method. Both show that the elastic deformation of the scatters is fully correlated with time shifts of the CWI differently from an acoustoelastic effect. As an illustration, the modeled sample is chosen as an effective medium aiming to mechanically and acoustically reproduce a typical granitic reservoir rock.Our numerical approach is compared to experimental results where multi-scattering of an acoustic wave through a perforated loaded Au4G (Dural) plate is performed at laboratory scale. Experimental and numerical results of the

  10. Measuring Responsible Gambling amongst Players: Development of the Positive Play Scale.

    Science.gov (United States)

    Wood, Richard T A; Wohl, Michael J A; Tabri, Nassim; Philander, Kahlil

    2017-01-01

    The modern gambling industry has, by-in-large, assumed a duty of care to minimize the risks associated with gambling, which has manifested in responsible gambling (RG) programming (e.g., educating players about the odds of success). The current study fills a void in gambling operators, regulators, and researchers ability to measure RG beliefs and behavior in their player-base, with the development and validation of the Positive Play Scale (PPS). In Study 1, we reviewed the literature and consulted 30 players as well as 10 RG experts to help generate a definition of RG beliefs and behavior that helped guide item generation. In Study 2, regular players ( N = 1,551) of a Canadian provincial gambling operator completed a positive play survey. Four components from a principal components analysis (PCA) were extracted: Honesty and Control, Pre-commitment, Personal Responsibility, and Gambling Literacy. The PPS subscales were either not associated with gambling frequency or had small-to-moderate negative relationships with frequency of play for games most often associated with disordered gambling (e.g., electronic games). In Study 3 ( N = 413), the factor structure of the PPS was confirmed and refined in a new sample of players. Moreover, a 1-month follow-up session demonstrated that the PPS has high test-retest reliability. The PPS is the first validated scale that reliably assesses the extent to which a consumer base has positive beliefs about gambling and gambles in a positive manner. The PPS can be used by the gambling industry to objectively assess the efficacy of their RG strategy, pinpoint specific areas for future focus, as well as examine the utility of new RG initiatives that aim to promote healthy patterns of gambling consumption. Furthermore, by examining the PPS scores for different player segments (e.g., sex, age, games played) it becomes possible to tailor RG strategy to the needs of specific players. In this way, RG strategy can be optimized by focusing

  11. The construction and validation of the homopositivity scale: an instrument measuring endorsement of positive stereotypes about gay men.

    Science.gov (United States)

    Morrison, Todd G; Bearden, Anomi G

    2007-01-01

    Social scientists appear to focus on negative beliefs about, and attitudes toward, gay men and lesbian women. This emphasis, though understandable in view of the widespread oppression of gay and lesbian individuals, is somewhat myopic because it ignores what might be referred to as the positive dimension of stereotypes. Although such a concept may appear oxymoronic, it is widely recognized that individuals may endorse a mixture of positive and negative stereotypes toward stigmatized groups such as African Americans and women. The purpose of the current series of studies (Study 1, N = 212; Study 2, N = 105) was to devise an instrument measuring endorsement of positive stereotypes about gay men (Homopositivity Scale; HPS). Two versions of the HPS (of varying length) were evaluated, with scale scores on both appearing to be internally consistent and factorially distinct from scales measuring negative stereotypes and prejudices about gay men. These studies also suggest that females are more likely than males to endorse positive stereotypes about gay men, and that such endorsement is negatively associated with need for uniqueness and need for cognition, and positively associated with media contact and benevolent sexism. The limitations of the two studies are outlined and the importance of assessing positive stereotypes about gay men in conjunction with oft-examined homonegativity is discussed.

  12. Positive phase error from parallel conductance in tetrapolar bio-impedance measurements and its compensation

    Directory of Open Access Journals (Sweden)

    Ivan M Roitt

    2010-01-01

    Full Text Available Bioimpedance measurements are of great use and can provide considerable insight into biological processes.  However, there are a number of possible sources of measurement error that must be considered.  The most dominant source of error is found in bipolar measurements where electrode polarisation effects are superimposed on the true impedance of the sample.  Even with the tetrapolar approach that is commonly used to circumvent this issue, other errors can persist. Here we characterise the positive phase and rise in impedance magnitude with frequency that can result from the presence of any parallel conductive pathways in the measurement set-up.  It is shown that fitting experimental data to an equivalent electrical circuit model allows for accurate determination of the true sample impedance as validated through finite element modelling (FEM of the measurement chamber.  Finally, the model is used to extract dispersion information from cell cultures to characterise their growth.

  13. Diameter and axial position measurement of micrometric particles by in-line digital holography using wavelet transform

    International Nuclear Information System (INIS)

    Torres, Y M; Amezquita, R; Monroy, F

    2011-01-01

    In this paper, the size and axial position of micrometric particles is obtained for an in-line Fraunhofer holography setup. The hologram reconstruction was realized using the wavelet transform. By digital image processing tools, the size distribution histogram for the particles in the sample was obtained. The contrast measurement in the amplitude reconstruction presents a peak when the axial coordinate and the register distance are equal. This fact lets the axial position in the sample be determined.

  14. Cellular Force Microscopy for in Vivo Measurements of Plant Tissue Mechanics1[W][OA

    Science.gov (United States)

    Routier-Kierzkowska, Anne-Lise; Weber, Alain; Kochova, Petra; Felekis, Dimitris; Nelson, Bradley J.; Kuhlemeier, Cris; Smith, Richard S.

    2012-01-01

    Although growth and morphogenesis are controlled by genetics, physical shape change in plant tissue results from a balance between cell wall loosening and intracellular pressure. Despite recent work demonstrating a role for mechanical signals in morphogenesis, precise measurement of mechanical properties at the individual cell level remains a technical challenge. To address this challenge, we have developed cellular force microscopy (CFM), which combines the versatility of classical microindentation techniques with the high automation and resolution approaching that of atomic force microscopy. CFM’s large range of forces provides the possibility to map the apparent stiffness of both plasmolyzed and turgid tissue as well as to perform micropuncture of cells using very high stresses. CFM experiments reveal that, within a tissue, local stiffness measurements can vary with the level of turgor pressure in an unexpected way. Altogether, our results highlight the importance of detailed physically based simulations for the interpretation of microindentation results. CFM’s ability to be used both to assess and manipulate tissue mechanics makes it a method of choice to unravel the feedbacks between mechanics, genetics, and morphogenesis. PMID:22353572

  15. PLS beam position measurement and feedback system

    International Nuclear Information System (INIS)

    Huang, J.Y.; Lee, J.; Park, M.K.; Kim, J.H.; Won, S.C.

    1992-01-01

    A real-time orbit correction system is proposed for the stabilization of beam orbit and photon beam positions in Pohang Light Source. PLS beam position monitoring system is designed to be VMEbus compatible to fit the real-time digital orbit feedback system. A VMEbus based subsystem control computer, Mil-1553B communication network and 12 BPM/PS machine interface units constitute digital part of the feedback system. With the super-stable PLS correction magnet power supply, power line frequency noise is almost filtered out and the dominant spectra of beam obtit fluctuations are expected to appear below 15 Hz. Using DSP board in SCC for the computation and using an appropriate compensation circuit for the phase delay by the vacuum chamber, PLS real-time orbit correction system is realizable without changing the basic structure of PLS computer control system. (author)

  16. Comprehensive Comparisons of Satellite Data, Signals, and Measurements between the BeiDou Navigation Satellite System and the Global Positioning System †

    Science.gov (United States)

    Jan, Shau-Shiun; Tao, An-Lin

    2016-01-01

    The Chinese BeiDou navigation satellite system (BDS) aims to provide global positioning service by 2020. The combined use of BDS and Global Positioning System (GPS) is proposed to provide navigation service with more stringent requirements. Actual satellite data, signals and measurements were collected for more than one month to analyze the positioning service qualities from both BDS and GPS. In addition to the conversions of coordinate and timing system, five data quality analysis (DQA) methods, three signal quality analysis (SQA) methods, and four measurement quality analysis (MQA) methods are proposed in this paper to improve the integrated positioning performance of BDS and GPS. As shown in the experiment results, issues related to BDS and GPS are resolved by the above proposed quality analysis methods. Thus, the anomalies in satellite data, signals and measurements can be detected by following the suggested resolutions to enhance the positioning performance of the combined use of BDS and GPS in the Asia Pacific region. PMID:27187403

  17. Measurement of the wire tension and position of the muon detector in the CMS project

    International Nuclear Information System (INIS)

    Niu Weiping

    2004-01-01

    The Large Hadron Collider (LHC) is currently being constructed at CERN including the ATLAS (A Toroidal LHC Apparatus) and CMS. It this report, it is have a sample introduction of CMS Muon detector, the drift tube introduction and chamber construction. The scope of this report covers the drift tube design and technical description; measurement of the wire tension of the Muon detector and the quality control; measurement of the wire position of the Muon detector and the quality control and so on. (authors)

  18. Stringent Nucleotide Recognition by the Ribosome at the Middle Codon Position

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2017-08-01

    Full Text Available Accurate translation of the genetic code depends on mRNA:tRNA codon:anticodon base pairing. Here we exploit an emissive, isosteric adenosine surrogate that allows direct measurement of the kinetics of codon:anticodon University of California base formation during protein synthesis. Our results suggest that codon:anticodon base pairing is subject to tighter constraints at the middle position than at the 5′- and 3′-positions, and further suggest a sequential mechanism of formation of the three base pairs in the codon:anticodon helix.

  19. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  20. Dynamic clinical measurements of voluntary vaginal contractions and autonomic vaginal reflexes.

    Science.gov (United States)

    Broens, Paul M A; Spoelstra, Symen K; Weijmar Schultz, Willibrord C M

    2014-12-01

    The vaginal canal is an active and responsive canal. It has pressure variations along its length and shows reflex activity. At present, the prevailing idea is that the vaginal canal does not have a sphincter mechanism. It is hypothesized that an active vaginal muscular mechanism exists and might be involved in the pathophysiology of genito-pelvic pain/penetration disorder. The aim of this study was to detect the presence of a canalicular vaginal "sphincter mechanism" by measuring intravaginal pressure at different levels of the vaginal canal during voluntary pelvic floor contractions and during induced reflexive contractions. Sixteen nulliparous women, without sexual dysfunction and pelvic floor trauma, were included in the study. High-resolution solid-state circumferential catheters were used to measure intravaginal pressures and vaginal contractions at different levels in the vaginal canal. Voluntary intravaginal pressure measurements were performed in the left lateral recumbent position only, while reflexive intravaginal pressure measurements during slow inflation of a vaginal balloon were performed in the left lateral recumbent position and in the sitting position. Intravaginal pressures and vaginal contractions were the main outcome measures. In addition, a general demographic and medical history questionnaire was administered to gain insight into the characteristics of the study population. Fifteen out of the sixteen women had deep and superficial vaginal high-pressure zones. In one woman, no superficial high-pressure zone was found. The basal and maximum pressures, as well as the duration of the autonomic reflexive contractions significantly exceeded the pressures and the duration of the voluntary contractions. There were no significant differences between the reflexive measurements obtained in the left lateral recumbent and the sitting position. The two high-pressure zones found in this study, as a result of voluntary contractions and, even more pronounced

  1. The influence of body position on Bielschowsky's test

    Directory of Open Access Journals (Sweden)

    Carlos R. Souza-Dias

    2014-04-01

    Full Text Available Purpose: To investigate the veracity of Jampolsky's statement that Bielschowsky's head tilt test is inverted if performed with the patient in the upside-down position and to interpret its neuromuscular mechanism. Methods: We present a series of 10 patients selected from a referred sample who were diagnosed with superior oblique paresis. Hypertropia was measured in the primary position, with the head erect and tilted toward both shoulders with the patient in the erect, supine, and upside-down positions. The last position was achieved by hanging the patient upside-down. Results: As expected, our results showed the veracity of Jampolsky's statement. The forced head tilt difference was inverted or significantly decreased when the test was performed in the upside-down position. Moreover, in all patients, Bielschowsky's phenomenon was neutralized in the supine body position, in which hypertropia with the head erect tended to vanish. In 3 patients, it disappeared completely. Conclusions: This study showed that, in patients with superior oblique paresis, differences in the extent of hypertropia in Bielschowsky's test tended to vanish when the test was performed with the patient in the supine position and invert when it was performed with the patient in the upside-down position.

  2. Entropy as a new measure of mechanical pain sensitivity in the masseter muscle

    DEFF Research Database (Denmark)

    Castrillon, Eduardo; Sato, Hitoshi; Tanosoto, Tomohiro

    ENTROPY AS A NEW MEASURE OF MECHANICAL PAIN SENSITIVITY IN THE MASSETER MUSCLE Author Block: E. E. Castrillon1, H. Sato2,3, T. Tanosoto4, T. Arima4, L. Baad-Hansen1, P. Svensson1, 1Clinical Oral Physiology, Århus Univ., Aarhus, Denmark, 2Dept. of Dentistry & Oral Physiology, Sch. of Med., Keio Un...... injections (Pmechanical pain sensitivity that captures new aspects of spatial characteristics and could therefore complement more classical assessments of TMD pain patients.......ENTROPY AS A NEW MEASURE OF MECHANICAL PAIN SENSITIVITY IN THE MASSETER MUSCLE Author Block: E. E. Castrillon1, H. Sato2,3, T. Tanosoto4, T. Arima4, L. Baad-Hansen1, P. Svensson1, 1Clinical Oral Physiology, Århus Univ., Aarhus, Denmark, 2Dept. of Dentistry & Oral Physiology, Sch. of Med., Keio Univ......., Tokyo, Japan, 3Japan Society for the Promotion of Sci., Tokyo, Japan, 4Dept. of Oral Rehabilitation, Graduate Sch. of Dental Med., Hokkaido Univ., Sapporo, Japan : Aim of Investigation: Manual palpation is a psychophysical technique to evaluate mechanical pain sensitivity in craniofacial muscles...

  3. The Research of Screw Thread Parameter Measurement Based on Position Sensitive Detector and Laser

    International Nuclear Information System (INIS)

    Tong, Q B; Ding, Z L; Chen, J C; Ai, L L; Yuan, F

    2006-01-01

    A technique and system of measuring screw thread parameter based on the theory of laser measurement is presented in this paper, which can be carried out the automated measurement of screw thread parameter. An inspection instrument was designed and produced, which included exterior imaging system of optical path, transverse displacement measurement system, axial displacement measurement system, and a module to deal with, control and assess the data in the upper system. The inspection and estimate of the screw thread contour curve were completed by using position sensitive device (PSD) as photoelectric detector to measure the coordinate data of the screw thread contour curve in the transverse section, and using precise raster to measure the axial displacement of the precision worktable under the screw thread test criterion., computer can gives a measured result according to coordinate data of the screw thread obtained by PSD. The relation between measured spot and image is established, and optimum design of the system organization are introduced, including the image length of receiving lens focal length optical system and the choice of PSD , and some main factor affected measuring precision are analyzed. The experimental results show that the measurement uncertainty of screw thread minor diameter can reach 0. 5μm, which can meet most requests for the measurement of screw thread parameter

  4. Mental Health Nursing, Mechanical Restraint Measures and Patients’ Legal Rights

    DEFF Research Database (Denmark)

    Birkeland, Søren; Gildberg, Frederik Alkier

    2016-01-01

    Abstract: Coercive mechanical restraint (MR) in psychiatry constitute the perhaps most important exception from the common health law requirement for involving patients in health care decisions and achieving their informed consent prior to treatment. Coercive measures and particularly MR constitute...... a serious collision with patient autonomy principles, pose a particular challenge to psychiatric patients’ legal rights, and put intensified demands on health professional performance. Legal rights principles require rationale for coercive measure use be thoroughly considered and rigorously documented....... This article presents an in-principle Danish Psychiatric Complaint Board decision concerning MR use initiated by untrained staff. The case illustrates that, judicially, weight must be put on the patient perspective on course of happenings and especially when health professional documentation is scant, patients...

  5. Measurement and inference of profile soil-water dynamics at different hillslope positions in a semiarid agricultural watershed

    Science.gov (United States)

    Green, Timothy R.; Erskine, Robert H.

    2011-12-01

    Dynamics of profile soil water vary with terrain, soil, and plant characteristics. The objectives addressed here are to quantify dynamic soil water content over a range of slope positions, infer soil profile water fluxes, and identify locations most likely influenced by multidimensional flow. The instrumented 56 ha watershed lies mostly within a dryland (rainfed) wheat field in semiarid eastern Colorado. Dielectric capacitance sensors were used to infer hourly soil water content for approximately 8 years (minus missing data) at 18 hillslope positions and four or more depths. Based on previous research and a new algorithm, sensor measurements (resonant frequency) were rescaled to estimate soil permittivity, then corrected for temperature effects on bulk electrical conductivity before inferring soil water content. Using a mass-conservation method, we analyzed multitemporal changes in soil water content at each sensor to infer the dynamics of water flux at different depths and landscape positions. At summit positions vertical processes appear to control profile soil water dynamics. At downslope positions infrequent overland flow and unsaturated subsurface lateral flow appear to influence soil water dynamics. Crop water use accounts for much of the variability in soil water between transects that are either cropped or fallow in alternating years, while soil hydraulic properties and near-surface hydrology affect soil water variability across landscape positions within each management zone. The observed spatiotemporal patterns exhibit the joint effects of short-term hydrology and long-term soil development. Quantitative methods of analyzing soil water patterns in space and time improve our understanding of dominant soil hydrological processes and provide alternative measures of model performance.

  6. In-situ position and vibration measurement of rough surfaces using laser Doppler distance sensors

    Science.gov (United States)

    Czarske, J.; Pfister, T.; Günther, P.; Büttner, L.

    2009-06-01

    In-situ measurement of distances and shapes as well as dynamic deformations and vibrations of fast moving and especially rotating objects, such as gear shafts and turbine blades, is an important task at process control. We recently developed a laser Doppler distance frequency sensor, employing two superposed fan-shaped interference fringe systems with contrary fringe spacing gradients. Via two Doppler frequency evaluations the non-incremental position (i.e. distance) and the tangential velocity of rotating bodies are determined simultaneously. The distance uncertainty is in contrast to e.g. triangulation in principle independent of the object velocity. This unique feature allows micrometer resolutions of fast moved rough surfaces. The novel sensor was applied at turbo machines in order to control the tip clearance. The measurements at a transonic centrifugal compressor were performed during operation at up to 50,000 rpm, i.e. 586 m/s velocity of the blade tips. Due to the operational conditions such as temperatures of up to 300 °C, a flexible and robust measurement system with a passive fiber-coupled sensor, using diffractive optics, has been realized. Since the tip clearance of individual blades could be temporally resolved an analysis of blade vibrations was possible. A Fourier transformation of the blade distances results in an average period of 3 revolutions corresponding to a frequency of 1/3 of the rotary frequency. Additionally, a laser Doppler distance sensor using two tilted fringe systems and phase evaluation will be presented. This phase sensor exhibits a minimum position resolution of σz = 140 nm. It allows precise in-situ shape measurements at grinding and turning processes.

  7. Positioning performance of a maglev fine positioning system

    Energy Technology Data Exchange (ETDEWEB)

    Wronosky, J.B.; Smith, T.G.; Jordan, J.D.; Darnold, J.R.

    1996-12-01

    A wafer positioning system was recently developed by Sandia National Laboratories for an Extreme Ultraviolet Lithography (EUVL) research tool. The system, which utilizes a magnetically levitated fine stage to provide ultra-precise positioning in all six degrees of freedom, incorporates technological improvements resulting from four years of prototype development experience. System enhancements, implemented on a second generation design for an ARPA National Center for Advanced Information Component Manufacturing (NCAICM) project, introduced active structural control for the levitated structure of the system. Magnetic levitation (maglev) is emerging as an important technology for wafer positioning systems in advanced lithography applications. The advantages of maglev stem from the absence of physical contact. The resulting lack of friction enables accurate, fast positioning. Maglev systems are mechanically simple, accomplishing full six degree-of-freedom suspension and control with a minimum of moving parts. Power-efficient designs, which reduce the possibility of thermal distortion of the platen, are achievable. Manufacturing throughput will be improved in future systems with the addition of active structural control of the positioning stages. This paper describes the design, implementation, and functional capability of the maglev fine positioning system. Specifics regarding performance design goals and test results are presented.

  8. Effect of heat and moisture exchanger (HME positioning on inspiratory gas humidification

    Directory of Open Access Journals (Sweden)

    Nishimura Masaji

    2006-08-01

    Full Text Available Abstract Background In mechanically ventilated patients, we investigated how positioning the heat and moisture exchanger (HME at different places on the ventilator circuit affected inspiratory gas humidification. Methods Absolute humidity (AH and temperature (TEMP at the proximal end of endotracheal tube (ETT were measured in ten mechanically ventilated patients. The HME was connected either directly proximal to the ETT (Site 1 or at before the circuit Y-piece (Site 2: distance from proximal end of ETT and Site 2 was about 19 cm (Figure. 1. Two devices, Hygrobac S (Mallinckrodt Dar, Mirandola, Italy and Thermovent HEPA (Smiths Medical International Ltd., Kent, UK were tested. AH and TEMP were measured with a hygrometer (Moiscope, MERA Co., Ltd., Tokyo, Japan. Results Hygrobac S provided significantly higher AH and TEMP at both sites than Thermovent HEPA. Both Hygrobac S and with Thermovent HEPA provided significantly higher AH and TEMP when placed proximally to the ETT. Conclusion Although placement proximal to the ETT improved both AH and TEMP in both HMEs tested, one HME performed better in the distal position than the other HME in the proximal position. We conclude the both the type and placement of HME can make a significant difference in maintaining AH and TEMP during adult ventilation.

  9. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification

    Science.gov (United States)

    Inui, Daisuke; Oto, Jun; Nishimura, Masaji

    2006-01-01

    Background In mechanically ventilated patients, we investigated how positioning the heat and moisture exchanger (HME) at different places on the ventilator circuit affected inspiratory gas humidification. Methods Absolute humidity (AH) and temperature (TEMP) at the proximal end of endotracheal tube (ETT) were measured in ten mechanically ventilated patients. The HME was connected either directly proximal to the ETT (Site 1) or at before the circuit Y-piece (Site 2: distance from proximal end of ETT and Site 2 was about 19 cm) (Figure. 1). Two devices, Hygrobac S (Mallinckrodt Dar, Mirandola, Italy) and Thermovent HEPA (Smiths Medical International Ltd., Kent, UK) were tested. AH and TEMP were measured with a hygrometer (Moiscope, MERA Co., Ltd., Tokyo, Japan). Results Hygrobac S provided significantly higher AH and TEMP at both sites than Thermovent HEPA. Both Hygrobac S and with Thermovent HEPA provided significantly higher AH and TEMP when placed proximally to the ETT. Conclusion Although placement proximal to the ETT improved both AH and TEMP in both HMEs tested, one HME performed better in the distal position than the other HME in the proximal position. We conclude the both the type and placement of HME can make a significant difference in maintaining AH and TEMP during adult ventilation. PMID:16895607

  10. The Positive Thinking Skills Scale: A screening measure for early identification of depressive thoughts.

    Science.gov (United States)

    Bekhet, Abir K; Garnier-Villarreal, Mauricio

    2017-12-01

    Depression is currently considered the second leading cause of disability worldwide. Positive thinking is a cognitive process that helps individuals to deal with problems more effectively, and has been suggested as a useful strategy for coping with adversity, including depression. The Positive Thinking Skills Scale (PTSS) is a reliable and valid measure that captures the frequency of use of positive thinking skills that can help in the early identification of the possibility of developing depressive thoughts. However, no meaningful cutoff score has been established for the PTSS. To establish a cutoff score for the PTSS for early identification of risk for depression. This study used a receiver operating characteristic (ROC) curve to establish a PTSS cutoff score for risk for depression, using the Center for Epidemiological Studies-Depression Scale (CES-D) as the gold standard measure. In a sample of 109 caregivers, the ROC showed that the cutoff score of PTSS that best classify the participants is 13.5. With this PTSS score, 77.8% of the subjects with low CES-D are classify correctly, and 69.6% of the subjects with high CES-D are classify correctly. Since the PTSS score should be integer numbers, functionally the cutoff would be 13. The study showed that a cut off score of 13 is a point at which referral, intervention, or treatment would be recommended. Consequently, this can help in the early identification of depressive symptoms that might develop because of the stress of caregiving. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A Molecular Mechanism to Regulate Lysosome Motility for Lysosome Positioning and Tubulation

    Science.gov (United States)

    Li, Xinran; Rydzewski, Nicholas; Hider, Ahmad; Zhang, Xiaoli; Yang, Junsheng; Wang, Wuyang; Gao, Qiong; Cheng, Xiping; Xu, Haoxing

    2016-01-01

    To mediate the degradation of bio-macromolecules, lysosomes must traffic towards cargo-carrying vesicles for subsequent membrane fusion or fission. Mutations of the lysosomal Ca2+ channel TRPML1 cause lysosome storage disease (LSD) characterized by disordered lysosomal membrane trafficking in cells. Here we show that TRPML1 activity is required to promote Ca2+-dependent centripetal movement of lysosomes towards the perinuclear region, where autophagosomes accumulate, upon autophagy induction. ALG-2, an EF-hand-containing protein, serves as a lysosomal Ca2+ sensor that associates physically with the minus-end directed dynactin-dynein motor, while PI(3,5)P2, a lysosome-localized phosphoinositide, acts upstream of TRPML1. Furthermore, the PI(3,5)P2-TRPML1-ALG-2-dynein signaling is necessary for lysosome tubulation and reformation. In contrast, the TRPML1 pathway is not required for the perinuclear accumulation of lysosomes observed in many LSDs, which is instead likely caused by secondary cholesterol accumulation that constitutively activates Rab7-RILP-dependent retrograde transport. Collectively, Ca2+ release from lysosomes provides an on-demand mechanism regulating lysosome motility, positioning, and tubulation. PMID:26950892

  12. Position Analysis of a Hybrid Serial-Parallel Manipulator in Immersion Lithography

    Directory of Open Access Journals (Sweden)

    Jie-jie Shao

    2015-01-01

    Full Text Available This paper proposes a novel hybrid serial-parallel mechanism with 6 degrees of freedom. The new mechanism combines two different parallel modules in a serial form. 3-P̲(PH parallel module is architecture of 3 degrees of freedom based on higher joints and specializes in describing two planes’ relative pose. 3-P̲SP parallel module is typical architecture which has been widely investigated in recent researches. In this paper, the direct-inverse position problems of the 3-P̲SP parallel module in the couple mixed-type mode are analyzed in detail, and the solutions are obtained in an analytical form. Furthermore, the solutions for the direct and inverse position problems of the novel hybrid serial-parallel mechanism are also derived and obtained in the analytical form. The proposed hybrid serial-parallel mechanism is applied to regulate the immersion hood’s pose in an immersion lithography system. Through measuring and regulating the pose of the immersion hood with respect to the wafer surface simultaneously, the immersion hood can track the wafer surface’s pose in real-time and the gap status is stabilized. This is another exploration to hybrid serial-parallel mechanism’s application.

  13. A combined stretching-tilting mechanism produces negative, zero and positive linear thermal expansion in a semi-flexible Cd(II)-MOF.

    Science.gov (United States)

    Lama, Prem; Das, Raj Kumar; Smith, Vincent J; Barbour, Leonard J

    2014-06-21

    A novel semi-flexible Cd(II)-MOF has been synthesized and characterized by variable temperature powder and single-crystal X-ray diffraction. The material displays an unusual combination of thermal expansion (TE) i.e. negative, zero and positive, which is an extremely rare finding, especially for metal-organic frameworks as a result of a combined stretching-tilting mechanism.

  14. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    Science.gov (United States)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  15. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2018-05-01

    Full Text Available The transfer impedance is a very important parameter of a beam position monitor (BPM which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables. This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  16. Online measurement of fluence and position for protontherapy beams

    Science.gov (United States)

    Benati, C.; Boriano, A.; Bourhaleb, F.; Cirio, R.; Cirrone, G. A. P.; Cornelius, I.; Cuttone, G.; Donetti, M.; Garelli, E.; Giordanengo, S.; Guérin, L.; La Rosa, A.; Luparia, A.; Marchetto, F.; Martin, F.; Meyroneinc, S.; Peroni, C.; Pittà, G.; Raffaele, L.; Sabini, M. G.; Valastro, L.

    2004-09-01

    Tumour therapy with proton beams has been used for several decades in many centres with very good results in terms of local control and overall survival. Typical pathologies treated with this technique are located in head and neck, eye, prostate and in general at big depths or close to critical organs. The Experimental Physics Department of the University of Turin and the local Section of INFN, in collaboration with INFN Laboratori Nazionali del Sud Catania and Centre de Protontherapie de Orsay Paris, have developed detector systems that allow the measurement of beam position and fluence, obtained in real time during beam delivery. The centre in Catania (CATANA: Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been treating patients with eye pathologies since spring 2002 using a superconducting cyclotron accelerating protons up to 62 MeV.This kind of treatments need high-resolution monitor systems and for this reason we have developed a 256-strip segmented ionisation chamber, each strip being 400 μm wide, with a total sensitive area 13×13 cm2. The Centre de Protontherapie de Orsay (CPO) has been operational since 1991 and features a synchrocyclotron used for eye and head and neck tumours with proton beams up to 200 MeV. The monitor system has to work on a large surface and for this purpose we have designed a pixel-segmented ionisation chamber, each pixel being 5×5 mm2, for a total active area of 16×16 cm2. The results obtained with two prototypes of the pixel and strip chambers demonstrate that the detectors allow the measurement of fluence and centre of gravity as requested by clinical specifications.

  17. Navicular bone position determined by positional MRI: a reproducibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Philip; Nybing, Janus D. [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Johannsen, Finn E.; Stallknecht, Sandra E. [Copenhagen University Hospital Bispebjerg, Institute of Sports Medicine Copenhagen, Copenhagen, NV (Denmark); Hangaard, Stine; Hansen, Bjarke B. [Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark); Boesen, Mikael [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark)

    2016-02-15

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  18. Navicular bone position determined by positional MRI: a reproducibility study

    International Nuclear Information System (INIS)

    Hansen, Philip; Nybing, Janus D.; Johannsen, Finn E.; Stallknecht, Sandra E.; Hangaard, Stine; Hansen, Bjarke B.; Boesen, Mikael

    2016-01-01

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  19. Mechanisms of Probe Tack Adhesion of Model Acrylic Elastomers

    Science.gov (United States)

    Lakrout, Hamed; Creton, Costantino; Ahn, Dongchan; Shull, Kenneth R.

    1997-03-01

    The adhesion mechanisms of model acrylate homopolymers and copolymers are studied with an instrumented probe tack test. A video camera positioned under the transparent glass substrate records the bonding and debonding process while the force displacement curve is acquired. This setup allows to couple the observation of the cavitation and fibrillation mechanisms, occurring during the debonding of the film from the stainless steel probe, with the mechanical measurement of stress and strain. The transitions between different debonding mechanisms are critically dicussed in terms of the bulk and surface properties of the adhesive and its molecular structure.

  20. On the existence of a minorant of the indefiniteness for the measurement of a position

    International Nuclear Information System (INIS)

    Ferretti, B.

    1984-01-01

    The purpose of this note is to prove, under the hypothesis of validity of: a)the Heisenberg indefiniteness principle, b)Lorentz transformation in a local inertial frame, c)the 'equivalence principle', the existence of a minorant of the indefiniteness for the measurement of a position. 'Planck radius' appears to be such a minorant

  1. Self-Management of Patient Body Position, Pose, and Motion Using Wide-Field, Real-Time Optical Measurement Feedback: Results of a Volunteer Study

    International Nuclear Information System (INIS)

    Parkhurst, James M.; Price, Gareth J.; Sharrock, Phil J.; Jackson, Andrew S.N.; Stratford, Julie; Moore, Christopher J.

    2013-01-01

    Purpose: We present the results of a clinical feasibility study, performed in 10 healthy volunteers undergoing a simulated treatment over 3 sessions, to investigate the use of a wide-field visual feedback technique intended to help patients control their pose while reducing motion during radiation therapy treatment. Methods and Materials: An optical surface sensor is used to capture wide-area measurements of a subject's body surface with visualizations of these data displayed back to them in real time. In this study we hypothesize that this active feedback mechanism will enable patients to control their motion and help them maintain their setup pose and position. A capability hierarchy of 3 different level-of-detail abstractions of the measured surface data is systematically compared. Results: Use of the device enabled volunteers to increase their conformance to a reference surface, as measured by decreased variability across their body surfaces. The use of visual feedback also enabled volunteers to reduce their respiratory motion amplitude to 1.7 ± 0.6 mm compared with 2.7 ± 1.4 mm without visual feedback. Conclusions: The use of live feedback of their optically measured body surfaces enabled a set of volunteers to better manage their pose and motion when compared with free breathing. The method is suitable to be taken forward to patient studies

  2. Properties of the center of gravity as an algorithm for position measurements: Two-dimensional geometry

    CERN Document Server

    Landi, Gregorio

    2003-01-01

    The center of gravity as an algorithm for position measurements is analyzed for a two-dimensional geometry. Several mathematical consequences of discretization for various types of detector arrays are extracted. Arrays with rectangular, hexagonal, and triangular detectors are analytically studied, and tools are given to simulate their discretization properties. Special signal distributions free of discretized error are isolated. It is proved that some crosstalk spreads are able to eliminate the center of gravity discretization error for any signal distribution. Simulations, adapted to the CMS em-calorimeter and to a triangular detector array, are provided for energy and position reconstruction algorithms with a finite number of detectors.

  3. Cylinder gauge measurement using a position sensitive detector

    International Nuclear Information System (INIS)

    St John, W. Doyle

    2007-01-01

    A position sensitive detector (PSD) has been used to determine the diameter of cylindrical pins based on the shift in a laser beam's centroid. The centroid of the light beam is defined here as the weighted average of position by the local intensity. A shift can be observed in the centroid of an otherwise axially symmetric light beam, which is partially obstructed. Additionally, the maximum shift in the centroid is a unique function of the obstructing cylinder diameter. Thus to determine the cylinder diameter, one only needs to detect this maximum shift as the cylinder is swept across the beam

  4. Positive Psychological Functioning: evidence for a new construct and its measurement

    Directory of Open Access Journals (Sweden)

    Mª Dolores Merino

    2015-01-01

    Full Text Available In 2007, the Institute of Happiness conducted one of the most ambitious studies ever done on this subject in Spain. Many different variables were measured: socio-demographics and psychological, (the latter through new instruments and all were applied to a representative sample of 3000 participants of the Spanish population. Study 1 of this research used that database. The objective of this Study was to understand how key psychological resources are organized (Autonomy, Resilience, Self-Esteem, Purpose in life, Enjoyment, Optimism, Curiosity, Creativity, Humor, Environmental mastery and Vitality. The purpose of Study 2 was to replicate the results of Study 1 and to test the psychometrical properties of the new scales used in Study 1, but using a sample of 130 college students. This research proves that key psychological resources are interconnected, forming a second order construct we call Positive Psychological Functioning (PPF, and, it develops a new Spanish scale to assess it. This measure is formed with 11 subscales each containing three items. This scale structure allows a general and a specific assessment of PPF and, in consequence, of human psychological well-being.

  5. Macroscopic Entangled State Generation with Optomechanical Coupling of Two Mechanical Modes

    Science.gov (United States)

    Weaver, Matthew; Luna, Fernando; Buters, Frank; Heeck, Kier; de Man, Sven; Bouwmeester, Dirk

    Mechanical resonators with a large quantum position uncertainty are an excellent test system for proposed decoherence mechanisms in massive systems. We present a scheme to optomechanically entangle two mechanical resonators with large frequency separation via two tone driving and single photon projection measurements. The quantum position uncertainty can be tuned with a variable optical pulse displacement operation, and independent single photon readout of the two resonators provides robust verification of the quantum states of the system. This scheme is currently experimentally feasible in a number of high mass opto- and electro-mechanical systems. We demonstrate one such system with two spatially and frequency separated Si3N4 trampoline resonators. We also show how the resonators can be coupled with two tone driving and the single photon optomechanical coupling rates can be tuned.

  6. Fast Kalman Filtering for Relative Spacecraft Position and Attitude Estimation for the Raven ISS Hosted Payload

    Science.gov (United States)

    Galante, Joseph M.; Van Eepoel, John; D'Souza, Chris; Patrick, Bryan

    2016-01-01

    The Raven ISS Hosted Payload will feature several pose measurement sensors on a pan/tilt gimbal which will be used to autonomously track resupply vehicles as they approach and depart the International Space Station. This paper discusses the derivation of a Relative Navigation Filter (RNF) to fuse measurements from the different pose measurement sensors to produce relative position and attitude estimates. The RNF relies on relative translation and orientation kinematics and careful pose sensor modeling to eliminate dependence on orbital position information and associated orbital dynamics models. The filter state is augmented with sensor biases to provide a mechanism for the filter to estimate and mitigate the offset between the measurements from different pose sensors

  7. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents pulmonary inflammation in patients without preexisting lung injury.

    Science.gov (United States)

    Wolthuis, Esther K; Choi, Goda; Dessing, Mark C; Bresser, Paul; Lutter, Rene; Dzoljic, Misa; van der Poll, Tom; Vroom, Margreeth B; Hollmann, Markus; Schultz, Marcus J

    2008-01-01

    Mechanical ventilation with high tidal volumes aggravates lung injury in patients with acute lung injury or acute respiratory distress syndrome. The authors sought to determine the effects of short-term mechanical ventilation on local inflammatory responses in patients without preexisting lung injury. Patients scheduled to undergo an elective surgical procedure (lasting > or = 5 h) were randomly assigned to mechanical ventilation with either higher tidal volumes of 12 ml/kg ideal body weight and no positive end-expiratory pressure (PEEP) or lower tidal volumes of 6 ml/kg and 10 cm H2O PEEP. After induction of anesthesia and 5 h thereafter, bronchoalveolar lavage fluid and/or blood was investigated for polymorphonuclear cell influx, changes in levels of inflammatory markers, and nucleosomes. Mechanical ventilation with lower tidal volumes and PEEP (n = 21) attenuated the increase of pulmonary levels of interleukin (IL)-8, myeloperoxidase, and elastase as seen with higher tidal volumes and no PEEP (n = 19). Only for myeloperoxidase, a difference was found between the two ventilation strategies after 5 h of mechanical ventilation (P volumes and PEEP may limit pulmonary inflammation in mechanically ventilated patients without preexisting lung injury. The specific contribution of both lower tidal volumes and PEEP on the protective effects of the lung should be further investigated.

  8. Setting individualized positive end-expiratory pressure level with a positive end-expiratory pressure decrement trial after a recruitment maneuver improves oxygenation and lung mechanics during one-lung ventilation.

    Science.gov (United States)

    Ferrando, Carlos; Mugarra, Ana; Gutierrez, Andrea; Carbonell, Jose Antonio; García, Marisa; Soro, Marina; Tusman, Gerardo; Belda, Francisco Javier

    2014-03-01

    We investigated whether individualized positive end-expiratory pressure (PEEP) improves oxygenation, ventilation, and lung mechanics during one-lung ventilation compared with standardized PEEP. Thirty patients undergoing thoracic surgery were randomly allocated to the study or control group. Both groups received an alveolar recruitment maneuver at the beginning and end of one-lung ventilation. After the alveolar recruitment maneuver, the control group had their lungs ventilated with a 5 cm·H2O PEEP, while the study group had their lungs ventilated with an individualized PEEP level determined by a PEEP decrement trial. Arterial blood samples, lung mechanics, and volumetric capnography were recorded at multiple timepoints throughout the procedure. The individualized PEEP values in study group were higher than the standardized PEEP values (10 ± 2 vs 5 cm·H2O; P decrement trial than with a standardized 5 cm·H2O of PEEP.

  9. Rocket measurements of positive ions during polar mesosphere winter echo conditions

    Directory of Open Access Journals (Sweden)

    A. Brattli

    2006-01-01

    Full Text Available On 18 January 2005, two small, instrumented rockets were launched from Andøya Rocket Range (69.3° N, 16° E during conditions with Polar Mesosphere Winter Echoes (PMWE. Each of the rockets was equipped with a Positive Ion Probe (PIP and a Faraday rotation/differential absorption experiment, and was launched as part of a salvo of meteorological rockets measuring temperature and wind using falling spheres and chaff. Layers of PMWE were detected between 55 and 77 km by the 53.5 MHz ALWIN radar. The rockets were launched during a solar proton event, and measured extremely high ion densities, of order 1010 m−3, in the region where PMWE were observed. The density measurements were analyzed with the wavelet transform technique. At large length scales, ~103 m, the power spectral density can be fitted with a k−3 wave number dependence, consistent with saturated gravity waves. Outside the PMWE layers the k−3 spectrum extends down to approximately 102 m where the fluctuations are quickly damped and disappear into the instrumental noise. Inside the PMWE layers the spectrum at smaller length scales is well fitted with a k−5/3 dependence over two decades of scales. The PMWE are therefore clearly indicative of turbulence, and the data are consistent with the turbulent dissipation of breaking gravity waves. We estimate a lower limit for the turbulent energy dissipation rate of about 10−2 W/kg in the upper (72 km layer.

  10. Position-controlled epitaxial III-V nanowires on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Roest, Aarnoud L; Verheijen, Marcel A; Wunnicke, Olaf; Serafin, Stacey; Wondergem, Harry; Bakkers, Erik P A M [Philips Research Laboratories, Professor Holstlaan 4, 5656 AA Eindhoven (Netherlands); Kavli Institute of NanoScience, Delft University of Technology, PO Box 5046, 2600 GA Delft (Netherlands)

    2006-06-14

    We show the epitaxial integration of III-V semiconductor nanowires with silicon technology. The wires are grown by the VLS mechanism with laser ablation as well as metal-organic vapour phase epitaxy. The hetero-epitaxial growth of the III-V nanowires on silicon was confirmed with x-ray diffraction pole figures and cross-sectional transmission electron microscopy. We show preliminary results of two-terminal electrical measurements of III-V nanowires grown on silicon. E-beam lithography was used to predefine the position of the nanowires.

  11. Position-controlled epitaxial III-V nanowires on silicon

    International Nuclear Information System (INIS)

    Roest, Aarnoud L; Verheijen, Marcel A; Wunnicke, Olaf; Serafin, Stacey; Wondergem, Harry; Bakkers, Erik P A M

    2006-01-01

    We show the epitaxial integration of III-V semiconductor nanowires with silicon technology. The wires are grown by the VLS mechanism with laser ablation as well as metal-organic vapour phase epitaxy. The hetero-epitaxial growth of the III-V nanowires on silicon was confirmed with x-ray diffraction pole figures and cross-sectional transmission electron microscopy. We show preliminary results of two-terminal electrical measurements of III-V nanowires grown on silicon. E-beam lithography was used to predefine the position of the nanowires

  12. High-precision relative position and attitude measurement for on-orbit maintenance of spacecraft

    Science.gov (United States)

    Zhu, Bing; Chen, Feng; Li, Dongdong; Wang, Ying

    2018-02-01

    In order to realize long-term on-orbit running of satellites, space stations, etc spacecrafts, in addition to the long life design of devices, The life of the spacecraft can also be extended by the on-orbit servicing and maintenance. Therefore, it is necessary to keep precise and detailed maintenance of key components. In this paper, a high-precision relative position and attitude measurement method used in the maintenance of key components is given. This method mainly considers the design of the passive cooperative marker, light-emitting device and high resolution camera in the presence of spatial stray light and noise. By using a series of algorithms, such as background elimination, feature extraction, position and attitude calculation, and so on, the high precision relative pose parameters as the input to the control system between key operation parts and maintenance equipment are obtained. The simulation results show that the algorithm is accurate and effective, satisfying the requirements of the precision operation technique.

  13. Positive ion mobilities in normal liquid 3He at ultralow temperatures

    International Nuclear Information System (INIS)

    Alexander, P.W.

    1978-11-01

    The mobility has been measured of positive ions in liquid 3 he in the range 2.5 mK 3 sub(m)/sup(V) 5 sub(m)/sup(V). The effects of 500 p.p.m. 4 He in the 3 He were investigated. It was found that, at low temperatures, several stable ion species could be produced for 3 He pressures of 23 bar and above and, between 25 mK and 60 mK, time dependent conversion from one species of ion to another was observed at all pressures. The creation mechanism, mobility and stability of multiple positive ions were studied. Possible explanations of the phenomena are discussed. The measured drift field dependence of mobility is used to test the quasiparticle scattering model assumed for the liquid. (U.K.)

  14. A high pulse repetition frequency ultrasound system for the ex vivo measurement of mechanical properties of crystalline lenses with laser-induced microbubbles interrogated by acoustic radiation force

    International Nuclear Information System (INIS)

    Yoon, Sangpil; Emelianov, Stanislav; Aglyamov, Salavat; Karpiouk, Andrei

    2012-01-01

    A high pulse repetition frequency ultrasound system for an ex vivo measurement of mechanical properties of an animal crystalline lens was developed and validated. We measured the bulk displacement of laser-induced microbubbles created at different positions within the lens using nanosecond laser pulses. An impulsive acoustic radiation force was applied to the microbubble, and spatio-temporal measurements of the microbubble displacement were assessed using a custom-made high pulse repetition frequency ultrasound system consisting of two 25 MHz focused ultrasound transducers. One of these transducers was used to emit a train of ultrasound pulses and another transducer was used to receive the ultrasound echoes reflected from the microbubble. The developed system was operating at 1 MHz pulse repetition frequency. Based on the measured motion of the microbubble, Young’s moduli of surrounding tissue were reconstructed and the values were compared with those measured using the indentation test. Measured values of Young’s moduli of four bovine lenses ranged from 2.6 ± 0.1 to 26 ± 1.4 kPa, and there was good agreement between the two methods. Therefore, our studies, utilizing the high pulse repetition frequency ultrasound system, suggest that the developed approach can be used to assess the mechanical properties of ex vivo crystalline lenses. Furthermore, the potential of the presented approach for in vivo measurements is discussed. (paper)

  15. Mechanical Design and Manufacturing Preparation of Loading Unloading Irradiation Facility in Reflector Irradiation Position

    International Nuclear Information System (INIS)

    Hasibuan, Djaruddin

    2004-01-01

    Base on planning to increase of the irradiation service quality in Multi purpose Reactor-GAS, the mechanical design and manufacturing of the (n,γ) irradiation facility has been done. The designed of (n,γ) irradiation facility is a new facility in Multi purpose Reactor-GAS. The design doing by design of stringer, guide bar and hanger. By the design installation, the continuous irradiation service of non fission reaction will be easy to be done without reactor shut down. The design of the facility needs 3 pieces Al pipe by 36 x 1.5 mm, a peace of Al round bar by 80 mm diameter and a piece of Al plate by 20 x 60 x 0.2 mm for the stringer and guide bar manufacturing. By the building of non fission irradiation facility in the reflector irradiation position, will make the irradiation service to be increased. (author)

  16. Heat loss mechanisms in a measurement of specific heat capacity of graphite

    International Nuclear Information System (INIS)

    Shipley, D.R.; Duane, S.

    1996-01-01

    Absorbed dose to graphite in electron beams with nominal energies in the range 3-20 MeV is determined by measuring the temperature rise in the core of a primary standard graphite calorimeter. This temperature rise is related to absorbed dose by a separate measurement of the specific heat capacity of the graphite core. There is, however, a small but significant amount of heat loss from the sample in the determination of specific heat capacity and corrections for these losses are required. This report discusses the sources of heat loss in the measurements and, where possible, provides estimates for the magnitude of these losses. For those mechanisms which are significant, a more realistic model of the measurement system is analysed and corrections for the losses are provided. (UK)

  17. Development of a 3D parallel mechanism robot arm with three vertical-axial pneumatic actuators combined with a stereo vision system.

    Science.gov (United States)

    Chiang, Mao-Hsiung; Lin, Hao-Ting

    2011-01-01

    This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot's end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H(∞) tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to

  18. MHD Collimation Mechanism in Arched Flux Ropes Characterized Using Volumetric, Time-Dependent B-Vector Measurements

    Science.gov (United States)

    Haw, Magnus A.; Bellan, Paul M.

    2017-10-01

    Laboratory measurements of B(x,t) in a volume enclosing portions of two arched flux ropes show flux rope collimation driven by gradients in axial current density. These measurements verify the three predictions of a proposed MHD collimation mechanism: (1) axial magnetic forces exist in current channels with spatially varying minor radius, (2) these forces can drive counterpropagating axial flows, and (3) this process collimates the flux rope. This mechanism may explain the axial uniformity of solar loops and is relevant to other systems with current channels of varying minor radius such as solar prominences and astrophysical jets.

  19. A0535+26: Refined position measurement and new pulse period data

    International Nuclear Information System (INIS)

    Li, F.; Rappaport, S.; Clark, G.W.; Jernigan, J.G.

    1979-01-01

    The hard, pulsing, transient X-ray source A0535+26 has been observed with SAS 3 on three occasions during 1977--1978. These observations have yielded a precise position measurement (20'' error radius) which renders the identification of A0535+26 with the Be star HDE 245770 virtually certain. The pulse phase was tracked for approx.9 days in 1978 April and clearly showed both first and second derivatives in the pulse period. An analysis of these new timing data, combined with data from previous observations, leads to the following conclusions: (1) a significant fraction of the observed changes in pulse period is probably intrinsic to the compact X-ray stae (e.g., accretion torques on a neutron star), and (2) conservative limits on binary orbital parameters tend to further confirm a long orbital period

  20. Identification of mechanisms in heavy ion reactions by measurement of angular correlations

    International Nuclear Information System (INIS)

    Carlin Filho, N.

    1987-01-01

    The identification of reaction mechanisms in light heavy-ion collisions has been performed within the framework of the three body kinematics, by means of angular correlation measurements. The 16 O+ 27 Al, 16 +O+ 28 Si and 10 B+ 27 Al reactions were investigated at Laboratory bombarding energies of 64 MeV, 64 and 48 MeV, respectively. Contributions of transfer-reemission and projectile sequential decay mechanisms were identified by the analysis of the relative kinetic energy of the final state components, excitation energies of the system at the intermediate stages, and also by means of fits to theoretical predictions for the angular correlations. (author) [pt

  1. Development of a position-sensitive fission counter and measurement of neutron flux distributions

    International Nuclear Information System (INIS)

    Yamagishi, Hideshi; Soyama, Kazuhiko; Kakuta, Tsunemi

    2001-08-01

    A position-sensitive fission counter (PSFC) that operates in high neutron flux and high gamma-ray background such as at the side of a power reactor vessel has been developed. Neutron detection using the PSFC with a solenoid electrode is based on a delay-line method. The PSFC that has the outer diameter of 25 mm and the sensitive length of 1000 mm was manufactured for investigation of the performances. The PSFC provided output current pulses that were sufficiently higher than the alpha noise, though the PSFC has a solenoid electrode and large electrode-capacitance. The S/N ratio of PSFC outputs proved to be higher than that of ordinary fission counters with 200 mm sensitive length. A performance test to measure neutron flux distributions by a neutron measuring system with the PSFC was carried out by the side of a graphite pile, W2.4 x H1.4 x L1.2 m, with neutron sources, Am-Be 370 GBq x 2. It was confirmed that the neutron flux distribution was well measured with the system. (author)

  2. A New Position Measurement System Using a Motion-Capture Camera for Wind Tunnel Tests

    Directory of Open Access Journals (Sweden)

    Yousok Kim

    2013-09-01

    Full Text Available Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS. The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape of the test specimen using system identification methods (frequency domain decomposition, FDD. By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape with the 3D measurements.

  3. The Infrared Imaging Spectrograph (IRIS) for TMT: multi-tiered wavefront measurements and novel mechanical design

    Science.gov (United States)

    Dunn, Jennifer; Andersen, David; Chapin, Edward; Reshetov, Vlad; Wierzbicki, Ramunas; Herriot, Glen; Chalmer, Dean; Isbrucker, Victor; Larkin, James E.; Moore, Anna M.; Suzuki, Ryuji

    2016-08-01

    The InfraRed Imaging Spectrograph (IRIS) will be the first light adaptive optics instrument on the Thirty Meter Telescope (TMT). IRIS is being built by a collaboration between Caltech, the University of California, NAOJ and NRC Herzberg. In this paper we present novel aspects of the Support Structure, Rotator and On-Instrument Wavefront Sensor systems being developed at NRC Herzberg. IRIS is suspended from the bottom port of the Narrow Field Infrared Adaptive Optics System (NFIRAOS), and provides its own image de-rotation to compensate for sidereal rotation of the focal plane. This arrangement is a challenge because NFIRAOS is designed to host two other science instruments, which imposes strict mass requirements on IRIS. As the mechanical design of all elements has progressed, we have been tasked with keeping the instrument mass under seven tonnes. This requirement has resulted in a mass reduction of 30 percent for the support structure and rotator compared to the most recent IRIS designs. To accomplish this goal, while still being able to withstand earthquakes, we developed a new design with composite materials. As IRIS is a client instrument of NFIRAOS, it benefits from NFIRAOS's superior AO correction. IRIS plays an important role in providing this correction by sensing low-order aberrations with three On-Instrument Wavefront Sensors (OIWFS). The OIWFS consists of three independently positioned natural guide star wavefront sensor probe arms that patrol a 2-arcminute field of view. We expect tip-tilt measurements from faint stars within the IRIS imager focal plane will further stabilize the delivered image quality. We describe how the use of On-Detector Guide Windows (ODGWs) in the IRIS imaging detector can be incorporated into the AO correction. In this paper, we present our strategies for acquiring and tracking sources with this complex AO system, and for mitigating and measuring the various potential sources of image blur and misalignment due to properties of

  4. A novel straightness measurement system applied to the position monitoring of large Particle Physics Detectors

    CERN Document Server

    Goudard, R; Ribeiro, R; Klumb, F

    1999-01-01

    The Compact Muon Solenoid experiment, CMS, is one of the two general purpose experiments foreseen to operate at the Large Hadron Collider, LHC, at CERN, the European Laboratory for Particle Physics. The experiment aims to study very high energy collisions of proton beams. Investigation of the most fundamental properties of matter, in particular the study of the nature of the electroweak symmetry breaking and the origin of mass, is the experiment scope. The central Tracking System, a six meter long cylinder with 2.4 m diameter, will play a major role in all physics searches of the CMS experiment. Its performance depends upon the intrinsic detector performance, on the stability of the supporting structure and on the overall survey, alignment and position monitoring system. The proposed position monitoring system is based on a novel lens-less laser straightness measurement method able to detect deviations from a nominal position of all structural elements of the Central Tracking system. It is based on the recipr...

  5. Simultaneous and spontaneous reversal of positional nystagmus; an unusual peripheral sign of benign paroxysmal positional vertigo

    Directory of Open Access Journals (Sweden)

    Sertac Yetiser, MD

    2017-06-01

    Full Text Available Direction-changing positional nystagmus is generally thought to be of central origin. Reversal of initial positional nystagmus during maintaining the head position in patients with benign paroxysmal positional vertigo (BPPV is quite unusual and could be a sign of peripheral pathology. Vestibular reflex adaptation, simultaneous co-existence of canalolithiasis and cupulolithiasis in the same or both ears and changing in direction of debris movement have been proposed for the mechanism of this phenomenon. This can be a sign of simultaneous ampullopedal and ampulofugal flows during single head movement. This double-phase pattern of flow causing reversal of positional nystagmus could be related with the amount, location and dispersal of otolithic debris inside the membranous labyrinth. Four patients (3 lateral canal canalolithiasis and 1 posterior canal with reversing spontaneous nystagmus among 530 patients with BPPV have been identified in our clinic. They have been cured with standard re-positioning maneuvers. Endolymphatic reflux theory has been proposed as the underlying mechanism for unusual behavior of otolithic debris.

  6. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing.

    Science.gov (United States)

    Ellis, J T; Healy, T M; Fontaine, A A; Saxena, R; Yoganathan, A P

    1996-11-01

    During recent clinical trials the Medtronic Parallel bileaflet mechanical heart valve was found to have an unacceptable number of valves with thrombus formation when implanted in the mitral position. Thrombi were observed in the hinge region and also in the upstream portion of the valve housing in the vicinity of the hinge. It was hypothesized that the flow conditions inside the hinge may have contributed to the thrombus formation. In order to investigate the flow structures within the hinge, laser Doppler anemometry (LDA) measurements were conducted in both steady and pulsatile flow at approximately 70 predetermined sites within the hinge region of a 27 mm Medtronic Parallel mitral valve with transparent housing. The pulsatile flow velocity measurements were animated in time using a graphical software package to visualize the hinge flow field throughout the cardiac cycle. The LDA measurements revealed that mean forward flow velocities through the hinge region were on the order of 0.10-0.20 m/s. In the inflow channel, a large vortical structure was present during diastole. Upon valve closure, peak reverse velocity reached 3 m/s close to the housing wall in the inflow channel. This area also experienced high turbulent shear stresses (> 6000 dynes/cm2) during the leakage flow phase. A disturbed, vortical flow was again present in the inflow channel after valve closure, while slightly above the leaflet peg and relief the flow was essentially stagnant. The high turbulent stresses near the top of the inflow channel, combined with a persistent vortex, implicate the inflow channel of the hinge as a likely region of thrombus formation. This experimental investigation revealed zones of flow stagnation in the inflow region of the hinge throughout the cardiac cycle and elevated turbulent shear stress levels in the inflow region during the leakage flow phase. These fluid mechanic phenomena are most likely a direct result of the complex geometry of the hinge of this valve

  7. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  8. Short period sound speed oscillation measured by intensive XBT survey and its role on GNSS/acoustic positioning

    Science.gov (United States)

    Kido, M.; Matsui, R.; Imano, M.; Honsho, C.

    2017-12-01

    In the GNSS/acoustic measurement, sound speed in ocean plays a key role of accuracy of final positioning. We have shown than longer period sound speed undulation can be properly estimated from GNSS-A analysis itself in our previous work. In this work, we have carried out intensive XBT measurement to get temporal variation of sound speed in short period to be compared with GNSS-A derived one. In the individual temperature profile obtained by intensive XBT measurements (10 minutes interval up to 12 times of cast), clear vertical oscillation up to 20 m of amplitude in the shallow part were observed. These can be interpreted as gravitational internal wave with short-period and hence short wavelength anomaly. Kido et al. (2007) proposed that horizontal variation of the ocean structure can be considered employing five or more transponders at once if the structure is expressed by two quantities, i.e., horizontal gradient in x/y directions. However, this hypothesis requires that the variation must has a large spatial scale (> 2-5km) so that the horizontal variation can be regarded as linear within the extent of acoustic path to seafloor transponders. Therefore the wavelength of the above observed internal wave is getting important. The observed period of internal wave was 30-60 minute. However its wavelength cannot be directly measured. It must be estimate based on density profile of water column. In the comparison between sound speed change and positioning, the delay of their phases were 90 degree, which indicates that most steep horizontal slope of internal wave correspond to largest apparent positioning shift.

  9. Excursions out-of-lane versus standard deviation of lateral position as outcome measure of the on-the-road driving test.

    Science.gov (United States)

    Verster, Joris C; Roth, Thomas

    2014-07-01

    The traditional outcome measure of the Dutch on-the-road driving test is the standard deviation of lateral position (SDLP), the weaving of the car. This paper explores whether excursions out-of-lane are a suitable additional outcome measure to index driving impairment. A literature search was conducted to search for driving tests that used both SDLP and excursions out-of-lane as outcome measures. The analyses were limited to studies examining hypnotic drugs because several of these drugs have been shown to produce next-morning sedation. Standard deviation of lateral position was more sensitive in demonstrating driving impairment. In fact, solely relying on excursions out-of-lane as outcome measure incorrectly classifies approximately half of impaired drives as unimpaired. The frequency of excursions out-of-lane is determined by the mean lateral position within the right traffic lane. Defining driving impairment as having a ΔSDLP > 2.4 cm, half of the impaired driving tests (51.2%, 43/84) failed to produce excursions out-of-lane. Alternatively, 20.9% of driving tests with ΔSDLP < 2.4 cm (27/129) had at least one excursion out-of-lane. Excursions out-of-lane are neither a suitable measure to demonstrate driving impairment nor is this measure sufficiently sensitive to differentiate adequately between differences in magnitude of driving impairment. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Measurement of the mean radial position of a lead ion beam in the CERN PS

    CERN Document Server

    Belleman, J; González, J; Johnston, S; Schulte, E C; Thivent, E

    1996-01-01

    The intensity of the lead ion beam in the PS, nominally 4×108 charges of Pb53+ per bunch, is too low for the closed orbit measurement system. However, for successful acceleration it is sufficient to know the mean radial position (MRP). A system was thus designed for simultaneous acquisition of revolution frequency and magnetic field. The frequency measurement uses a direct digital synthesiser (DDS), phase-locked to the beam signal from a special high-sensitivity pick-up. The magnetic field is obtained from the so-called B-train. From these two values, the MRP is calculated. The precision depends on the frequency measurement and on the accuracy of the value for the magnetic field. Furthermore, exact knowledge of the transition energy is essential. This paper describes the hardware and software developed for the MRP system, and discusses the issue of calibration, with a proton beam, of the B measurement.

  11. Geometric modeling of controlled third-class hinged mechanisms with a stand in one extreme position for cyclic automatic machines

    Science.gov (United States)

    Khomchenko, V. G.; Varepo, L. G.; Glukhov, V. I.; Krivokhatko, E. A.

    2017-06-01

    The geometric model for the synthesis of third-class lever mechanisms is proposed, which allows, by changing the length of the auxiliary link and the position of its fixed hinge, to rearrange the movement of the working organ onto the cyclograms with different predetermined dwell times. It is noted that with the help of the proposed model, at the expense of the corresponding geometric constructions, the best uniform Chebyshev approximation can be achieved at the interval of the standstill.

  12. Spinodal decomposition mechanism study on the duplex stainless steel UNS S31803 using ultrasonic speed measurements

    International Nuclear Information System (INIS)

    Albuquerque, Victor Hugo C. de; Macedo Silva, Edgard de; Pereira Leite, Josinaldo; Pindo de Moura, Elineudo; Araujo Freitas, Vera Lucia de; Tavares, Joao Manuel R.S.

    2010-01-01

    This work, focuses on the spinodal decomposition mechanism study on the duplex stainless steel duplex UNS S31803, composed by austenite (γ) and ferrite (α) phases, at 425 o C and 475 o C temperatures by ultrasonic speed measurements. This temperature range is responsible for the transformation mechanism of α initial phase to α phases (poor in chromium) and α' (rich in chromium) by spinodal decomposition. The techniques to accomplish this analysis are based mainly on X-ray diffraction measures and ultrasonic speed. The obtained results show that it is possible to conclude that the use of ultrasonic speed measurements indicates a promising technique for following-up the phase transformation and spinodal decomposition on the steel studied.

  13. QUANTUM MECHANICS. Quantum squeezing of motion in a mechanical resonator.

    Science.gov (United States)

    Wollman, E E; Lei, C U; Weinstein, A J; Suh, J; Kronwald, A; Marquardt, F; Clerk, A A; Schwab, K C

    2015-08-28

    According to quantum mechanics, a harmonic oscillator can never be completely at rest. Even in the ground state, its position will always have fluctuations, called the zero-point motion. Although the zero-point fluctuations are unavoidable, they can be manipulated. Using microwave frequency radiation pressure, we have manipulated the thermal fluctuations of a micrometer-scale mechanical resonator to produce a stationary quadrature-squeezed state with a minimum variance of 0.80 times that of the ground state. We also performed phase-sensitive, back-action evading measurements of a thermal state squeezed to 1.09 times the zero-point level. Our results are relevant to the quantum engineering of states of matter at large length scales, the study of decoherence of large quantum systems, and for the realization of ultrasensitive sensing of force and motion. Copyright © 2015, American Association for the Advancement of Science.

  14. Automatically-Activated Attitudes as Mechanisms for Message Effects: The Case of Alcohol Advertisements.

    Science.gov (United States)

    Goodall, Catherine E; Slater, Michael D

    2010-10-01

    Alcohol advertisements may influence impulsive, risky behaviors indirectly, via automatically-activated attitudes toward alcohol. Results from an experiment in which participants were exposed to either four alcohol advertisements, four control advertisements, or four drunk driving public service advertisements, suggested that alcohol advertisements had more measurable effects on implicit, than on explicit attitude measures. Moreover, there were significant indirect paths from alcohol advertisement exposure through automatically-activated alcohol attitudes on willingness to engage in risky alcohol-related behaviors, notably drinking and driving. A mechanism that may explain how these advertisements activate automatic, non-deliberative alcohol attitudes was investigated. Associative evidence was found supportive of an evaluative conditioning mechanism, in which positive responses to an alcohol advertisement may lead to more positive automatically-activated attitudes toward alcohol itself.

  15. Bridging the Measurement Gap Between Research and Clinical Care in Schizophrenia: Positive and Negative Syndrome Scale-6 (PANSS-6) and Other Assessments Based on the Simplified Negative and Positive Symptoms Interview (SNAPSI).

    Science.gov (United States)

    Østergaard, Søren D; Opler, Mark G A; Correll, Christoph U

    2017-12-01

    There is currently a "measurement gap" between research and clinical care in schizophrenia. The main reason behind this gap is that the most widely used rating scale in schizophrenia research, the 30-item Positive and Negative Syndrome Scale (PANSS), takes so long to administer that it is rarely used in clinical practice. This compromises the translation of research findings into clinical care and vice versa. The aim of this paper is to discuss how this measurement gap can be closed. Specifically, the main points of discussion are 1) the practical problems associated with using the full 30-item PANSS in clinical practice; 2) how the brief, six-item version of the Positive and Negative Syndrome Scale (PANSS-6) was derived empirically from the full 30-item PANSS and what the initial results obtained with PANSS-6 entail; and 3) how PANSS-6 ratings, guided by the newly developed, 15-25-minute, stand-alone Simplified Negative and Positive Symptoms Interview (SNAPSI), might help bridge the measurement gap between research and clinical care in schizophrenia. The full 30-item PANSS is often used in research studies, but is too time consuming to allow for routine clinical use. Recent studies suggest that the much briefer PANSS-6 is a psychometrically valid measure of core positive and negative symptoms of schizophrenia and that the scale is sensitive to symptom improvement following pharmacological treatment. SNAPSI is a brief interview that yields the information needed to rate PANSS-6 (and other brief rating scales). We believe that PANSS-6 ratings guided by SNAPSI will help bridge the measurement gap between research and clinical care in schizophrenia.

  16. A New Three-Dimensional Indoor Positioning Mechanism Based on Wireless LAN

    Directory of Open Access Journals (Sweden)

    Jiujun Cheng

    2014-01-01

    Full Text Available The researches on two-dimensional indoor positioning based on wireless LAN and the location fingerprint methods have become mature, but in the actual indoor positioning situation, users are also concerned about the height where they stand. Due to the expansion of the range of three-dimensional indoor positioning, more features must be needed to describe the location fingerprint. Directly using a machine learning algorithm will result in the reduced ability of classification. To solve this problem, in this paper, a “divide and conquer” strategy is adopted; that is, first through k-medoids algorithm the three-dimensional location space is clustered into a number of service areas, and then a multicategory SVM with less features is created for each service area for further positioning. Our experiment shows that the error distance resolution of the approach with k-medoids algorithm and multicategory SVM is higher than that of the approach only with SVM, and the former can effectively decrease the “crazy prediction.”

  17. Role of the reference position on overpotential measurements

    Directory of Open Access Journals (Sweden)

    Figueiredo, F. M.

    1999-12-01

    Full Text Available Steady state polarisation measurements can be affected by electrode microstructure and geometrical arrangement. In particular, the relative position of the reference electrode with respect to the working and counter electrodes may influence the reference potential and therefore effect the overvoltage readings. The influence of the geometrical arrangement of the electrodes on the electrolyte potential lines, was simulated by solving the appropriate Maxwell equations. Simulations were in relatively good agreement with steady state polarisation and impedance spectroscopy results obtained with YSZ|LaMnO3-based cells. The use of impedance spectroscopy to assess the appropriateness of a given electrode configuration is suggested.

    La medida de los estados de polarización fijos puede estar afectada por la microestructura del electrodo y su configuración geométrica. En particular, la posición relativa del electrodo de referencia en relación con los electrodos de trabajo y conteo puede influenciar el potencial de referencia y por lo tanto afectar las lecturas de sobrevoltaje. La influencia de la configuración geométrica de los electrodos sobre las líneas potenciales del electrolito fue simulada por resolución de las ecuaciones de Maxwell apropiadas. Las simulaciones estuvieron en relativamente buen acuerdo con el estado de polariazación fijo y los resultados de espectroscopía de impedancia obtenidos con células basadas en YSZ|LaMnO3. Se sugiere el uso de espectroscopía de impedancias para valorar la conveniencia de una configuración de electrodo.

  18. Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation.

    Science.gov (United States)

    Zheng, Dingchang; Pan, Fan; Murray, Alan

    2013-10-01

    The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.

  19. An efficient fluorescent single-particle position tracking system for long-term pulsed measurements of nitrogen-vacancy centers in diamond

    Science.gov (United States)

    Kim, Kiho; Yun, Jiwon; Lee, Donghyuck; Kim, Dohun

    2018-02-01

    A simple and convenient design enables real-time three-dimensional position tracking of nitrogen-vacancy (NV) centers in diamond. The system consists entirely of commercially available components (a single-photon counter, a high-speed digital-to-analog converter, a phase-sensitive detector-based feedback device, and a piezo stage), eliminating the need for custom programming or rigorous optimization processes. With a large input range of counters and trackers combined with high sensitivity of single-photon counting, high-speed position tracking (upper bound recovery time of 0.9 s upon 250 nm of step-like positional shift) not only of bright ensembles, but also of low-photon-collection-efficiency single to few NV centers (down to 103 s-1) is possible. The tracking requires position modulation of only 10 nm, which allows simultaneous position tracking and pulsed measurements in the long term. Therefore, this tracking system enables measuring a single-spin magnetic resonance and Rabi oscillations at a very high resolution even without photon collection optimization. The system is widely applicable to various fields related to NV center quantum manipulation research such as NV optical trapping, NV tracking in fluid dynamics, and biological sensing using NV centers inside a biological cell.

  20. [Evaluating the accuracy of three-dimensional reconstruction of the intercuspal position for dentition casts aided by a mechanical appliance].

    Science.gov (United States)

    Hu, Z W; Li, W W; Zhang, X Y; Fan, B L; Wang, Y; Sun, Y C

    2016-08-01

    To develop a aided mechanical appliance for rapid reconstruction of three-dimensional(3D)relationship of dentition model after scanning and evaluation of its accuracy. The appliance was designed by forward engineering software and fabricated by a high precision computer numerical control(CNC)system. It contained upper and lower body, magnetic pedestal and three pillars. Nine 3 mm diameter hemispheres were distributed equally on the axial surface of each pedestal. Faro Edge 1.8m was used to directly obtain center of each hemisphere(contact method), defined as known center. A pair of die-stone standard dentition model were fixed in intercuspal position and then fixed on the magnetic pedestals with low expansion ratio plaster. Activity 880 dental scanner was used to scan casts after the plaster was completely set. In Geomagic 2012, the centers of each hemisphere were fitted and defined as scanning centers. Scanning centers were aligned to known centers by reference point system to finish the 3D reconstruction of the intercuspal occlusion for the dentition casts. An observation coordinate system was interactively established. The straight-line distances in the X(coronal), Y(saggital), and Z(vertical)between the remaining 6 pairs of center points derived from contact method and fitting method were measured respectively and analyzed using a paired t-test. The differences of the straight-line distances of the remaining 6 pairs of center points between the two methods were X:(-0.05±0.10)mm, Y:(0.02±0.06)mm, and Z:(0.01 ± 0.05)mm. The results of paired t-test showed no significant differences(P>0.05). The mechanical appliance can help to reconstruct 3D jaw relation by scanning single upper and lower dentition model with usual commercial available dental cast scanning system.