WorldWideScience

Sample records for position anode position

  1. Position-sensitive proportional counter with low-resistance metal-wire anode

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which uses a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counther. A pair of specially designed activecapacitance preamplifiers terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, lownoise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at te anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates

  2. What is the optimal anodal electrode position for inducing corticomotor excitability changes in transcranial direct current stimulation?

    Science.gov (United States)

    Lee, Minji; Kim, Yun-Hee; Im, Chang-Hwan; Kim, Jung-Hoon; Park, Chang-hyun; Chang, Won Hyuk; Lee, Ahee

    2015-01-01

    Transcranial direct current stimulation (tDCS) non-invasively modulates brain function by inducing neuronal excitability. The conventional hot spot for inducing the highest current density in the hand motor area may not be the optimal site for effective stimulation. In this study, we investigated the influence of the center position of the anodal electrode on changes in motor cortical excitability. We considered three tDCS conditions in 16 healthy subjects: (i) real stimulation with the anodal electrode located at the conventional hand motor hot spot determined by motor evoked potentials (MEPs); (ii) real stimulation with the anodal electrode located at the point with the highest current density in the hand motor area as determined by electric current simulation; and (iii) sham stimulation. Motor cortical excitability as measured by MEP amplitude increased after both real stimulation conditions, but not after sham stimulation. Stimulation using the simulation-derived anodal electrode position, which was found to be posterior to the MEP hot spot for all subjects, induced higher motor cortical excitability. Individual positioning of the anodal electrode, based on the consideration of anatomical differences between subjects, appears to be important for maximizing the effects of tDCS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  4. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  5. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  6. Rapid temperature increase near the anode and cathode in the afterglow of a pulsed positive streamer discharge

    Science.gov (United States)

    Ono, Ryo

    2018-06-01

    The spatiotemporal evolution of the temperature in the afterglow of point-to-plane, pulsed positive streamer discharge was measured near the anode tip and cathode surface using laser-induced predissociation fluorescence of OH radicals. The temperature exhibited a rapid increase and displayed a steep spatial gradient after a discharge pulse. The rate of temperature rise reached 84 K μs‑1 at mm, where z represents the distance from the anode tip. The temperature rise was much faster than in the middle of the gap; it was only 2.8 K μs‑1 at mm. The temperature reached 1700 K near the anode tip at s and 1500 K near the cathode surface at s, where t represents the postdischarge time. The spatial gradient reached 1280 K mm‑1 near the anode tip at s. The mechanism responsible for the rapid temperature increase was discussed, including rapid heating of the gas in the early postdischarge phase (s), and vibration-to-translation energy transfer in the later postdischarge phase (s). The high temperatures near the anode tip and cathode surface are particularly important for the ignition of combustible mixtures and for surface treatments, including solid-surface treatments, water treatments, and plasma medicine using pulsed streamer discharges.

  7. Production of lithium positive ions from LiF thin films on the anode in PBFA II

    International Nuclear Information System (INIS)

    Green, T.A.; Stinnett, R.W.; Gerber, R.A.

    1995-09-01

    The production of positive lithium ions using a lithium-fluoride-coated stainless steel anode in the particle beam fusion accelerator PBFA II is considered from both the experimental and theoretical points of view. It is concluded that the mechanism of Li + ion production is electric field desorption from the tenth-micron-scale crystallites which compose the columnar growth of the LiF thin film. The required electric field is estimated to be of the order of 5 MV/cm. An essential feature of the mechanism is that the crystallites are rendered electronically conducting through electron-hole pair generation by MeV electron bombardment of the thin film during the operation of the diode. It is proposed that the ion emission mechanism is an electronic conductivity analogue to that discovered by Rollgen for lithium halide crystallites which were rendered ionically conducting by heating to several hundred degrees Celsius. Since an electric field desorption mechanism cannot operate if a surface flashover plasma has formed and reduced the anode electric field to low values, the possibility of flashover on the lithium fluoride coated anode of the PBFA II Li + ion source is studied theoretically. It is concluded with near certainty that flashover does not occur

  8. Ion extraction from positively biased laser-ablation plasma

    International Nuclear Information System (INIS)

    Isono, Fumika; Nakajima, Mitsuo; Hasegawa, Jun; Horioka, Kazuhiko

    2016-01-01

    Ions were extracted through a grounded grid from a positively biased laser-ablation plasma and the behaviors were investigated. Since the plasma was positively biased against the grounded wall, we could extract the ions without insulated gap. We confirmed formation of a virtual anode when we increased the distance between the grid and the ion collector. Results also indicated that when the ion flux from the ablation plasma exceeded a critical value, the current was strongly suppressed to the space charge limited level due to the formation of virtual anode.

  9. MHSP with position detection capability

    Energy Technology Data Exchange (ETDEWEB)

    Natal da Luz, H. [Physics Dept., University of Aveiro, 3810-193 Aveiro (Portugal); Physics Dept., University of Coimbra, 3004-516 Coimbra (Portugal); Veloso, J.F.C.A. [Physics Dept., University of Aveiro, 3810-193 Aveiro (Portugal) and Physics Dept., University of Coimbra, 3004-516 Coimbra (Portugal)]. E-mail: jveloso@fis.ua.pt; Mendes, N.F.C. [Physics Dept., University of Coimbra, 3004-516 Coimbra (Portugal); Santos, J.M.F. dos [Physics Dept., University of Coimbra, 3004-516 Coimbra (Portugal); Mir, J.A. [CCLRC Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom)

    2007-04-01

    The first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 {omega} resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout.

  10. Two dimension position sensitive multi-plate PPAC

    International Nuclear Information System (INIS)

    Mao Ruishi; Guo Zhongyan; Xiao Guoqing; Zhan Wenlong; Xu Hushan; Hu Zhengguo; Wang Meng; Sun Zhiyu; Chen Zhiqiang; Chen Lixin; Li Chen; Bai Jie; Zhang Jinxia; Li Cunfan

    2003-01-01

    A two-dimensional positional sensitive multi-plate PPAC with resistance chain readout has been developed for Radioactive Ion Beam Line in Lanzhou (RIBLL). The PPAC has an active area of 100 mm x 100 mm. It consists of an anode plane, a x wire plane, a y wire plane and two cathode planes. The gaps between anode and wire planes are 3 mm. And the gaps between cathodes and wire planes also are 3 mm. When filled with iso-butane at a pressure of 6.5 mb, the 0.58 mm (FWHM) position resolution and >99.2% detection efficiencies and <±50 μm linearity of the PPAC was estimated for 3 components α source

  11. Position sensitive proportional counter for measurement of tritium labelled gas movement

    International Nuclear Information System (INIS)

    Mori, Chizuo; Nakamoto, Makihiko; Uritani, Akira; Watanabe, Tamaki

    1984-01-01

    A position sensitive proportional counter of a charge division type with a single resistive anode wire was constructed for the measurement of the movement of 3 H labelled gas which is flowing or diffusing in a pipe. The introduction of resistors between the anode wire and pre-amplifiers brought a uniform detection efficiency for 3 H β-rays throughout the counter. The position resolution was 3.1 mm FWHM. Detection efficiency was almost 100% uniformly over about 700 mm in the total anode length of 740 mm. The movement of 3 H labelled gas could be measured effectively. (author)

  12. Peak position differences observed during XPS sputter depth profiling of the SEI on lithiated and delithiated carbon-based anode material for Li-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Oswald, S., E-mail: s.oswald@ifw-dresden.de; Hoffmann, M.; Zier, M.

    2017-04-15

    Highlights: • In XPS measurements at graphite anodes for Li-ion batteries specific binding energy variations are observed for the SEI species. • The binding energy variations depend on the charging state of the graphite and not on surface charging effects. • Obviously the presence of elemental Li leads to a potential surface gradient in contact with surface layers. • The energy position of implanted Ar can be used as characteristic feature during sputter depth profiling experiments. - Abstract: The ability of delivering chemical information from peak shift phenomena has ever since made X-ray photoelectron spectroscopy (XPS) an ideal tool for material characterization in Li-ion batteries (LIB). Upon investigation, charging is inevitable as most of the chemical species involved are non-conducting. Thus, the binding energy (BE) scale must be corrected to allow an accurate interpretation of the results. This is usually done using the peak position of the ubiquitous surface carbon contamination detectable for all Li-ion battery relevant materials. We herein report on the occurrence of peak shift phenomena that can be observed when investigating surface layers on graphite anodes using sputter depth-profiling. These shifts, however, are not related to classical static electric charging, but are depending on the state of charge (lithiation) of the anode material. The observations presented are in agreement with previous findings on other Li-containing materials and are obviously caused by the presence of Li in its elemental state. As aging and failure mechanisms in LIBs are closely linked to electrolyte reaction products on electrode surfaces it is of high importance to draw the correct conclusions on their chemical origin from XP spectra. In order to avoid misinterpretation of the BE positions, implanted Ar can be used for identification of relevant peak positions and species involved in the phenomena observed.

  13. Time-of-flight position-sensitive x-ray detection

    International Nuclear Information System (INIS)

    Mowat, J.W.

    1981-01-01

    A new method for recording beam-foil time-of-flight data is described. A stationary, side-window, position-senstive proportional counter, oriented with anode wire parallel to the ion beam, views the decay in flight of excited ions through a Soller slit x-ray collimator. In contrast to the standard method, the exciter foil, placed within or upstream from the field of view, is not moved during the acquisition of a decay curve. Each point on the anode acts like an independent detector seeing a unique segment of the ion beam. The correspondence between the downstream distance at which an ion decays and the position along the anode at which the x-ray is detected makes a pulse-height spectrum of position pulses equivalent to a time-of-flight decay curve. Thus an entire decay curve can now be acquired without moving the foil. Increased efficiency is the most significant improvement over the standard method in which the radiation detector views only a small segment of the flight path at any one time. Experiments using translating foils are subject to a spurious dependence of x-ray intensity on foil position if the foil is non-uniform (or non-uniformly aged) and wobbles as it moves. This effect is eliminated here. Foil aging effects which influence excitation rates and introduce a slowly varying time dependence of the x-ray intensity are automatically normalized by this multichannel technique. The application of this method to metastable x-ray emitting states of low-Z ions are discussed

  14. A large area two-dimensional position sensitive multiwire proportional detector

    CERN Document Server

    Moura, M M D; Souza, F A; Alonso, E E; Fujii, R J; Meyknecht, A B; Added, N; Aissaoui, N; Cardenas, W H Z; Ferraretto, M D; Schnitter, U; Szanto, E M; Szanto de Toledo, A; Yamamura, M S; Carlin, N

    1999-01-01

    Large area two-dimensional position sensitive multiwire proportional detectors were developed to be used in the study of light heavy-ion nuclear reactions at the University of Sao Paulo Pelletron Laboratory. Each detector has a 20x20 cm sup 2 active area and consists of three grids (X-position, anode and Y-position) made of 25 mu m diameter gold plated tungsten wires. The position is determined through resistive divider chains. Results for position resolution, linearity and efficiency as a function of energy and position for different elements are reported.

  15. Position resolution of MSGCs with cathode readout

    International Nuclear Information System (INIS)

    Amos, N.; Cremaldi, L.; Finocchiaro, G.; Gobbi, B.; Ng, K.K.; Manzella, V.; Peskov, V.; Rajagopalan, S.; Rubinov, P.; Schamberger, D.; Sellberg, G.; Steffens, J.; Tilden, R.; Wang, P.; Yu, Y.

    1997-01-01

    The performance of a telescope of micro-strip gas chambers (MSGC) has been studied in a beam of pions. Detectors with different anode pitch and with different substrates have been operated using several gas mixtures. The position resolutions obtained by reading out the cathodes for the 200 μm pitch is 42 μm. For the 400 μm pitch detectors the resolution is 42 μm after correcting the centroid positions with a function derived from the data. (orig.)

  16. Position-sensitive radiation detector

    International Nuclear Information System (INIS)

    Mathieson, E.; Smith, G.C.; Gilvin, P.J.

    1981-01-01

    Apparatus for sensing the position of radiation received has a plurality of receptors spaced in at least one line on which the position is to be determined, their outputs being associated to form at least two groups, the density of the receptors in each group varying along the line. The receptors may comprise cathode arrays of a multiwire proportional counter, with an anode array between, measuring along lines in directions x and y respectively. The density of the wires in the two groups, decreases in opposite directions. A circuit determines the ratio of the output of one group to the sum of the group outputs. In another embodiment a scintillator is viewed by a plurality of light guides, the ends of which adjacent to the scintillator form the receptors, the four groups of which each terminate on a photomultiplier. (author)

  17. Anode sheath transition in an anodic arc for synthesis of nanomaterials

    Science.gov (United States)

    Nemchinsky, V. A.; Raitses, Y.

    2016-06-01

    The arc discharge with ablating anode or so-called anodic arc is widely used for synthesis of nanomaterials, including carbon nanotubes and fullerens, metal nanoparticles etc. We present the model of this arc, which confirms the existence of the two different modes of the arc operation with two different anode sheath regimes, namely, with negative anode sheath and with positive anode sheath. It was previously suggested that these regimes are associated with two different anode ablating modes—low ablation mode with constant ablation rate and the enhanced ablation mode (Fetterman et al 2008 Carbon 46 1322). The transition of the arc operation from low ablation mode to high ablation mode is determined by the current density at the anode. The model can be used to self-consistently determine the distribution of the electric field, electron density and electron temperature in the near-anode region of the arc discharge. Simulations of the carbon arc predict that for low arc ablating modes, the current is driven mainly by the electron diffusion to the anode. For positive anode sheath, the anode voltage is close to the ionization potential of anode material, while for negative anode sheath, the anode voltage is an order of magnitude smaller. It is also shown that the near-anode plasma, is far from the ionization equilibrium.

  18. Anode sheath transition in an anodic arc for synthesis of nanomaterials

    International Nuclear Information System (INIS)

    Nemchinsky, V A; Raitses, Y

    2016-01-01

    The arc discharge with ablating anode or so-called anodic arc is widely used for synthesis of nanomaterials, including carbon nanotubes and fullerens, metal nanoparticles etc. We present the model of this arc, which confirms the existence of the two different modes of the arc operation with two different anode sheath regimes, namely, with negative anode sheath and with positive anode sheath. It was previously suggested that these regimes are associated with two different anode ablating modes—low ablation mode with constant ablation rate and the enhanced ablation mode (Fetterman et al 2008 Carbon 46 1322). The transition of the arc operation from low ablation mode to high ablation mode is determined by the current density at the anode. The model can be used to self-consistently determine the distribution of the electric field, electron density and electron temperature in the near-anode region of the arc discharge. Simulations of the carbon arc predict that for low arc ablating modes, the current is driven mainly by the electron diffusion to the anode. For positive anode sheath, the anode voltage is close to the ionization potential of anode material, while for negative anode sheath, the anode voltage is an order of magnitude smaller. It is also shown that the near-anode plasma, is far from the ionization equilibrium. (paper)

  19. Anode Sheath Switching in a Carbon Nanotube Arc Plasma

    International Nuclear Information System (INIS)

    Fetterman, Abe; Raitses, Yevgeny; Keidar, Michael

    2008-01-01

    The anode ablation rate is investigated as a function of anode diameter for a carbon nanotube arc plasma. It is found that anomalously high ablation occurs for small anode diameters. This result is explained by the formation of a positive anode sheath. The increased ablation rate due to this positive anode sheath could imply greater production rate for carbon nanotubes.

  20. Three-dimensional, position-sensitive radiation detection

    Science.gov (United States)

    He, Zhong; Zhang, Feng

    2010-04-06

    Disclosed herein is a method of determining a characteristic of radiation detected by a radiation detector via a multiple-pixel event having a plurality of radiation interactions. The method includes determining a cathode-to-anode signal ratio for a selected interaction of the plurality of radiation interactions based on electron drift time data for the selected interaction, and determining the radiation characteristic for the multiple-pixel event based on both the cathode-to-anode signal ratio and the electron drift time data. In some embodiments, the method further includes determining a correction factor for the radiation characteristic based on an interaction depth of the plurality of radiation interactions, a lateral distance between the selected interaction and a further interaction of the plurality of radiation interactions, and the lateral positioning of the plurality of radiation interactions.

  1. Numerical simulation for rib and channel position effect on PEMFC performances

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhixiang; Wang, Cheng; Mao, Zongqiang [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Zhang, Haiyong [Lab of Sail, Cable and Paints, Navy Equipment Technology Institute, Beijing, 102442 (China)

    2010-04-15

    Simulation is an important method for engineers to probe the detailed transportation and reaction information inside fuel cells and guide their designs without large amount of experiments. Although many papers discussing fuel cell flow fields design could be found in documents, relative positions of the ribs and channels in the anode and cathode flow field plates haven't been paid attention to surprisingly. In this paper, simulation results were given to explain the influences of relative positions of the ribs and channels in the anode and cathode flow field plates on the proton exchange membrane fuel cell (PEMFC) performances. It is interesting that the influence differs with several factors and the information will be helpful for fuel cell design. (author)

  2. Positive magnetoresistance in Fe3Se4 nanowires

    Science.gov (United States)

    Li, D.; Jiang, J. J.; Liu, W.; Zhang, Z. D.

    2011-04-01

    We report the magnetotransport properties of Fe3Se4 nanowire arrays in anodic aluminum oxide (AAO) porous membrane. The temperature dependence of resistance of Fe3Se4 nanowires at a zero field shows thermal activated behavior below 295 K. The exponential relationship in resistance is consistent with the model of strong localization with variable-range hopping (VRH) for a finite one-dimensional wire. Resistance versus magnetic field curves below 100 K show small positive magnetoresistance (MR). The field dependencies of log[R(H)/R(0)] explain the positive MR as the effect of magnetic field on the VRH conduction.

  3. New Position Algorithms for the 3-D CZT Drift Detector

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.

    2017-06-01

    The 3-D position sensitive CZT detector for high-energy astrophysics developed at DTU has been investigated with a digitizer readout system. The 3-D CZT detector is based on the CZT drift-strip detector principle and was fabricated using a REDLEN CZT crystal (20 mm × 20 mm × 5 mm). The detector contains 12 drift cells, each comprising one collecting anode strip with four drift strips, biased such that the electrons are focused and collected by the anode strips. Three-dimensional position determination is achieved using the anode strip signals, the drift-strip signals, and the signals from ten cathode strips. For the characterization work, we used a DAQ system with a 16 channels 250-MHz 14-b digitizer, SIS3316. It allowed us to analyze the pulse shapes of the signals from four detector cells at a time. The 3-D CZT setup was characterized with a finely collimated radioactive source of 137Cs at 662 keV. The analysis required development of novel position determination algorithms which are the subject of this paper. Using the digitizer readout, we demonstrate improved position determination compared to the previous read out system based on analog electronics. Position resolutions of 0.4-mm full width at half maximum (FWHM) in the x-, y-, and z-directions were achieved and the energy resolution was 7.2-keV FWHM at 662 keV. The timing information allows identification of multiple interaction events within one detector cell, e.g., Compton scattering followed by photoelectric absorption. These characteristics are very important for a high-energy spectral-imager suitable for use in advanced Compton telescopes, or as focal detector for new hard X-ray and soft γ-ray focusing telescopes or in polarimeter instrumentation. CZT detectors are attractive for these applications since they offer relatively high-quantum efficiency. From a technical point of view it is advantageous that their cooling requirements are modest.

  4. Reconnection and merging of positive streamers in air

    Energy Technology Data Exchange (ETDEWEB)

    Nijdam, S; Geurts, C G C; Van Veldhuizen, E M; Ebert, U, E-mail: s.nijdam@tue.n [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands)

    2009-02-21

    Pictures show that streamer or sprite discharge channels emerging from the same electrode sometimes seem to reconnect or merge though their heads carry electric charge of the same polarity; one might therefore suspect that reconnections are an artefact of the two-dimensional projection in the pictures. Here we use stereo photography to investigate the full three-dimensional structure of such events. We analyse reconnection, possibly an electrostatic effect in which a late thin streamer reconnects to an earlier thick streamer channel, and merging, a suggested photoionization effect in which two simultaneously propagating streamer heads merge into one new streamer. We use four different anode geometries (one tip, two tips, two asymmetric protrusions in a plate and a wire), placed 40 mm above a flat cathode plate in ambient air. A positive high voltage pulse is applied to the anode, creating a positive corona discharge. This discharge is studied with a fast ICCD camera, in many cases combined with optics to enable stereoscopic imaging. We find that reconnections as defined above occur frequently. Merging on the other hand was only observed at a pressure of 25 mbar and a tip separation of 2 mm, i.e. for a reduced tip distance of p{center_dot}d = 50 {mu}m bar. In this case the full width at half maximum of the streamer channel is more than 10 times as large as the tip separation. At higher pressures or with a wire anode, merging was not observed.

  5. Reconnection and merging of positive streamers in air

    International Nuclear Information System (INIS)

    Nijdam, S; Geurts, C G C; Van Veldhuizen, E M; Ebert, U

    2009-01-01

    Pictures show that streamer or sprite discharge channels emerging from the same electrode sometimes seem to reconnect or merge though their heads carry electric charge of the same polarity; one might therefore suspect that reconnections are an artefact of the two-dimensional projection in the pictures. Here we use stereo photography to investigate the full three-dimensional structure of such events. We analyse reconnection, possibly an electrostatic effect in which a late thin streamer reconnects to an earlier thick streamer channel, and merging, a suggested photoionization effect in which two simultaneously propagating streamer heads merge into one new streamer. We use four different anode geometries (one tip, two tips, two asymmetric protrusions in a plate and a wire), placed 40 mm above a flat cathode plate in ambient air. A positive high voltage pulse is applied to the anode, creating a positive corona discharge. This discharge is studied with a fast ICCD camera, in many cases combined with optics to enable stereoscopic imaging. We find that reconnections as defined above occur frequently. Merging on the other hand was only observed at a pressure of 25 mbar and a tip separation of 2 mm, i.e. for a reduced tip distance of p·d = 50 μm bar. In this case the full width at half maximum of the streamer channel is more than 10 times as large as the tip separation. At higher pressures or with a wire anode, merging was not observed.

  6. Anode Fall Formation in a Hall Thruster

    International Nuclear Information System (INIS)

    Dorf, Leonid A.; Raitses, Yevgeny F.; Smirnov, Artem N.; Fisch, Nathaniel J.

    2004-01-01

    As was reported in our previous work, accurate, nondisturbing near-anode measurements of the plasma density, electron temperature, and plasma potential performed with biased and emissive probes allowed the first experimental identification of both electron-repelling (negative anode fall) and electron-attracting (positive anode fall) anode sheaths in Hall thrusters. An interesting new phenomenon revealed by the probe measurements is that the anode fall changes from positive to negative upon removal of the dielectric coating, which appears on the anode surface during the course of Hall thruster operation. As reported in the present work, energy dispersion spectroscopy analysis of the chemical composition of the anode dielectric coating indicates that the coating layer consists essentially of an oxide of the anode material (stainless steel). However, it is still unclear how oxygen gets into the thruster channel. Most importantly, possible mechanisms of anode fall formation in a Hall thruster with a clean and a coated anodes are analyzed in this work; practical implication of understanding the general structure of the electron-attracting anode sheath in the case of a coated anode is also discussed

  7. Time and positioning characteristics of the SQS mode

    International Nuclear Information System (INIS)

    Fraga, F.A.F. de; Ferreira Marques, R.; Policarpo, A.J.P.L.; Coimbra Univ.; Coimbra Univ.

    1989-01-01

    Previous results on the azimuthal localization of punctual interactions using the self-quenching streamer (SQS) mode, as given by the direction of the SQS avalanche, have shown a marked improvement in resolution when the current pulses are integrated for short times. In this work, data concerning the position resolution along the wire in the SQS mode for the argon-48% isobutane mixture, using a 55 Fe source, are presented. Essentially the same effect was detected: The FWHM, larger than 500 μm for the total signal duration, is reduced to about 300 μm for a 10 ns gate. This improvement in position resolution is practically independent of the anode voltage, all along the plateau. (orig.)

  8. Position detectors, methods of detecting position, and methods of providing positional detectors

    Science.gov (United States)

    Weinberg, David M.; Harding, L. Dean; Larsen, Eric D.

    2002-01-01

    Position detectors, welding system position detectors, methods of detecting various positions, and methods of providing position detectors are described. In one embodiment, a welding system positional detector includes a base that is configured to engage and be moved along a curved surface of a welding work piece. At least one position detection apparatus is provided and is connected with the base and configured to measure angular position of the detector relative to a reference vector. In another embodiment, a welding system positional detector includes a weld head and at least one inclinometer mounted on the weld head. The one inclinometer is configured to develop positional data relative to a reference vector and the position of the weld head on a non-planar weldable work piece.

  9. Application of digital waveform processing to position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Takenaka, Yasuto; Uritani, Akira; Mori, Chizuo

    1995-01-01

    In a charge-division type position-sensitive proportional counter (PSPC) with an anode wire of small resistance, a reflected component from an opposite end and thermal noise involved in signals deteriorate the position resolution of the PSPC. A digital waveform processing method was applied to the reduction of these undesirable effects by skillfully utilizing their signal characteristics that can be observed as inversely correlative signals between two-output signals from both sides of the PSPC. The digital waveform processing could improve the position resolution compared to a conventional pulse height processing method with analog filters. When the digital waveform processing was applied to signals of an equivalent circuit simulating the PSPC, the position resolutions defined by the full width at half maximum were improved to about 30% of those of conventional analog pulse processing. In the case of an actual PSPC, the position resolutions by the digital waveform processing were improved by 4-10% as compared with those of conventional pulse height processing. (author)

  10. Output pulse-shapes of position-sensitive proportional counters using high resistance single wire

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Nishiyama, Fumitaka; Hasai, Hiromi

    1980-01-01

    The measurements and model analysis of the output pulse-shapes from a single wire proportional counter (SWPC) which has a high resistance anode are described. The characteristics of the observed pulse-shapes are determined by only one parameter which is a function of anode resistance and load resistance and they are reproduced by a simple model. Using this model, the methods for position read-out are discussed in a systematical way. (author)

  11. Synthesis of Azanucleosides by Anodic Oxidation in a Lithium Perchlorate-Nitroalkane Medium and Diversification at the 4'-Nitrogen Position.

    Science.gov (United States)

    Shoji, Takao; Kim, Shokaku; Chiba, Kazuhiro

    2017-03-27

    Azanucleosides, in which the 4'-oxygen atom has been replaced with a nitrogen atom, have drawn much attention owing to their anticancer and antivirus activity, and tolerance towards nucleases. However, the traditional synthetic strategy requires multiple steps and harsh conditions, thereby limiting the structural and functional diversity of the products. Herein we describe the synthesis of azanucleosides by an electrochemical reaction in a lithium perchlorate-nitroethane medium, followed by postmodification at the 4'-N position. N-Acryloyl prolinol derivatives were converted into azanucleosides by anodic activation of the N-α-C-H bond. Moreover, the use of nitroethane instead of nitromethane lowered the oxidation potential of the N-acryloyl prolinols and increased the Faradic yield. The prepared azanucleosides were efficiently functionalized at the 4'-N-acryloyl group with a lipophilic alkanethiol and a fluorescent dye by conjugate addition and olefin cross-metathesis, respectively. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Angle-resolved ion TOF spectrometer with a position sensitive detector

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Norio [Electrotechnical Lab., Tsukuba, Ibaraki (Japan); Heiser, F; Wieliczec, K; Becker, U

    1996-07-01

    A angle-resolved ion time-of-flight mass spectrometer with a position sensitive anode has been investigated. Performance of this spectrometer has been demonstrated by measuring an angular distribution of a fragment ion pair, C{sup +} + O{sup +}, from CO at the photon energy of 287.4 eV. The obtained angular distribution is very close to the theoretically expected one. (author)

  13. High resolution multiple sampling ionization chamber (MUSIC) sensitive to position coordinates

    International Nuclear Information System (INIS)

    Petrascu, H.; Kumagai, H.; Tanihata, I.; Petrascu, M.

    1999-01-01

    A new type of MUSIC sensitive to position coordinates is reported. The development of the first version of this type of chamber is based on the principles presented by Badhwar in 1973. The present detector will be used in experiments on fusion by using radioactive beams. This chamber due to the high resolution is suitable to identification and tracking of low Z particles. One of our goals, when we started this work, was to reduce as much as possible the Z value of particles that can be 'seen' by an ionization chamber. The resolution of the chamber was significantly improved by connecting the preamplifiers directly to the MUSIC's pads. These preamplifiers are able to work in vacuum and very low gas pressure. In this way the value of signal to noise ratio was increased by a factor of ∼10. The detector is of Frisch grid type, with the anode split into 10 active pads. It is the first model of a MUSIC with the field shared between the position grid and the anode pads. The Frisch grid was necessary because the detector is originally designed for very accurate energy measurements and particle identification. A drawing of this detector is shown. The detector itself consists of four main parts. The first one is the constant field-gradient cage, sandwiched in between the cathode and the Frisch grid. The second is the Frisch grid. The third is the position grid located under the Frisch grid. The last one is the plate with the anode pads. The cage is made of 100 μm Cu-Be wires. Every wire was tensioned with a weight representing half of its breaking limit. The Frisch grid was done on an aluminium frame, on which 20 μm W wires spaced 0.3 mm, were wound. For the position grid, 10 groups of 20 μm gold plated W wires have been used. Each group consisted of 5 wires spaced 0.9 mm and connected in parallel. The anode pads 7.8 x 60 mm 2 were perpendicular to the beam direction. Each pad and each of the position wire groups were connected to a preamplifier. The energy resolution

  14. Studies of pyrrole black electrodes as possible battery positive electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Mengoli, G.; Musiani, M.M.; Fleischmann, M.; Pletcher, D.

    1984-05-01

    It is shown that a polypyrrole, pyrrole black, may be formed anodically in several aqueous acids. The polypyrrole film shows a redox couple at less positive potentials than that required to form the film and the charge associated with these reduction and oxidation processes together with their stabilty to cycling varies with the anion in solution and the potential where the polypyrrole is formed; over-oxidation of the film caused by taking its potential too positive has a particularly disadvantageous affect. In the acids HBr and HI, the polypyrrole films can act as a storage medium for Br/sub 2/ or I/sub 2/ so that they may be used as a substrate for a X/sub 2//X/sup -/ electrode. Such electrodes may be charge/discharge cycled and the pyrrole/Br/sub 2/ electrode shows promise as a battery positive electrode.

  15. Tests of crossed-wire position sensitive photomultipliers for scintillating fiber particle tracking

    International Nuclear Information System (INIS)

    Perdrisat, C.F.; Koechner, D.; Majewski, S.; Pourang, R.; Wilson, C.D.; Zorn, C.

    1995-01-01

    Several applications of two Hamamatsu position sensitive photomultiplier tubes to the detection of high energy particles with scintillating fibers are discussed. The PMTs are of the multiwire anode grid design, type R2486 and R4135. These tubes were tested with both single samples and arrays of 2 and 3 mm diameter scintillating fibers. Measurements of position resolution of the PMTs using either the charge digitization or the delay line readout techniques were made. The results indicate an intrinsic inability of the technique to reconstruct the actual position of a fiber on the photocathode when its location falls halfway between two grid wires. A way to overcome this limit is suggested. (orig.)

  16. The optimal timing of stimulation to induce long-lasting positive effects on episodic memory in physiological aging.

    Science.gov (United States)

    Manenti, Rosa; Sandrini, Marco; Brambilla, Michela; Cotelli, Maria

    2016-09-15

    Episodic memory displays the largest degree of age-related decline. A noninvasive brain stimulation technique that can be used to modulate memory in physiological aging is transcranial Direct Current Stimulation (tDCS). However, an aspect that has not been adequately investigated in previous studies is the optimal timing of stimulation to induce long-lasting positive effects on episodic memory function. Our previous studies showed episodic memory enhancement in older adults when anodal tDCS was applied over the left lateral prefrontal cortex during encoding or after memory consolidation with or without a contextual reminder. Here we directly compared the two studies to explore which of the tDCS protocols would induce longer-lasting positive effects on episodic memory function in older adults. In addition, we aimed to determine whether subjective memory complaints would be related to the changes in memory performance (forgetting) induced by tDCS, a relevant issue in aging research since individuals with subjective memory complaints seem to be at higher risk of later memory decline. The results showed that anodal tDCS applied after consolidation with a contextual reminder induced longer-lasting positive effects on episodic memory, conceivably through reconsolidation, than anodal tDCS during encoding. Furthermore, we reported, providing new data, a moderate negative correlation between subjective memory complaints and forgetting when anodal tDCS was applied after consolidation with a contextual reminder. This study sheds light on the best-suited timing of stimulation to induce long-lasting positive effects on memory function and might help the clinicians to select the most effective tDCS protocol to prevent memory decline. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Electronic properties of electrolyte/anodic alumina junction during porous anodizing

    Energy Technology Data Exchange (ETDEWEB)

    Vrublevsky, I. [Department of Microelectronics, Belarusian State University of Informatics and Radioelectronics, 6 Brovka Street, Minsk 220013 (Belarus)]. E-mail: nil-4-2@bsuir.edu.by; Jagminas, A. [Institute of Chemistry, A. Gostauto 9, LT-01108 Vilnius (Lithuania); Schreckenbach, J. [Institut fuer Chemie, Technische Universitaet Chemnitz, Chemnitz D-09107 (Germany); InnoMat GmbH, Chemnitz (Germany); Goedel, Werner A. [Institut fuer Chemie, Technische Universitaet Chemnitz, Chemnitz D-09107 (Germany)

    2007-03-15

    The growth of porous oxide films on aluminum (99.99% purity), formed in 4% phosphoric acid was studied as a function of the anodizing voltage (23-53 V) using a re-anodizing technique and transmission electron microscopy (TEM) study. The chemical dissolution behavior of freshly anodized and annealed at 200 deg. C porous alumina films was studied. The obtained results indicate that porous alumina has n-type semiconductive behavior during anodizing in 4% phosphoric acid. During anodising, up to 39 V in the barrier layer of porous films, one obtains an accumulation layer (the thickness does not exceed 1 nm) where the excess electrons have been injected into the solid producing a downward bending of the conductive and valence band towards the interface. The charge on the surface of anodic oxide is negative and decreases with growing anodizing voltage. At the anodizing voltage of about 39 V, the charge on the surface of anodic oxide equals to zero. Above 39 V, anodic alumina/electrolyte junction injects protons from the electrolyte. These immobile positive charges in the surface layer of oxide together with an ionic layer of hydroxyl ions concentrated near the interface create a field, which produces an upward bending of the bands.

  18. Positive Technologies for Understanding and Promoting Positive Emotions.

    Science.gov (United States)

    Baños, Rosa María; Carrillo, Alba; Etchemendy, Ernestina; Botella, Cristina

    2017-10-26

    Information and Communication Technologies (ICTs) have become increasingly present in our lives, and their use has spread considerably. This paper presents a review of the way ICTs can help practitioners and researchers to study, promote, and train positive emotions. It is framed within the field of Positive Technologies: the applied scientific approach to the study of the use of technology to improve the quality of personal experience, with the goal of increasing wellbeing. First, the article presents an introduction to the topic of technologies and positive emotions. Then, it describes how ICTs can aid in monitoring, assessing, promoting, modifying, and training positive emotions. Finally, implications and future directions of the role of Positive Technologies in positive emotions are discussed. The authors conclude that, in the near future, Positive Technologies and the field of positive emotions will interact synergistically, producing an exponential growth in the understanding and promotion of positive emotions.

  19. Dynamic Characteristics of Positive Pulsed Dielectric Barrier Discharge for Ozone Generation in Air

    International Nuclear Information System (INIS)

    Wei Linsheng; Peng Bangfa; Li Ming; Zhang Yafang; Hu Zhaoji

    2016-01-01

    A comprehensive dynamic model consisting of 66 reactions and 24 species is developed to investigate the dynamic characteristics of ozone generation by positive pulsed dielectric barrier discharge (DBD) using parallel-plate reactor in air. The electron energy conservation equation is coupled to the electron continuity equation, the heavy species continuity equation, and Poisson's equation for a better description. The reliability of the model is experimentally confirmed. The model can be used to predict the temporal and spatial evolution of species, as well as streamer propagation. The simulation results show that electron density increases nearly exponentially in the direction to the anode at the electron avalanche. Streamer propagation velocity is about 5.26 × 10 4 m/s from anode to cathode in the simulated condition. The primary positive ion, negative ion, and excited species are O 2 + , O 3 − and O 2 ( 1 Δg) in pulsed DBD in air, respectively. N 2 O has the largest density among nitrogen oxides. e and N 2 + densities in the streamer head increase gradually to maximum values with the development of the streamer. Meanwhile, the O 2 + , O, O 3 , N 2 (A 3 Σ) and N 2 O densities reach maximum values in the vicinity of the anode. (paper)

  20. Are positive emotions just as "positive" across cultures?

    Science.gov (United States)

    Leu, Janxin; Wang, Jennifer; Koo, Kelly

    2011-08-01

    Whereas positive emotions and feeling unequivocally good may be at the heart of well-being among Westerners, positive emotions often carry negative associations within many Asian cultures. Based on a review of East-West cultural differences in dialectical emotions, or co-occurring positive and negative feelings, we predicted culture to influence the association between positive emotions and depression, but not the association between negative emotions and depression. As predicted, in a survey of over 600 European-, immigrant Asian-, and Asian American college students, positive emotions were associated with depression symptoms among European Americans and Asian Americans, but not immigrant Asians. Negative emotions were associated with depression symptoms among all three groups. We also found initial evidence that acculturation (i.e., nativity) may influence the role of positive emotions in depression: Asian Americans fell "in between" the two other groups. These findings suggest the importance of studying the role of culture in positive emotions and in positive psychology. The use of interventions based on promoting positive emotions in clinical psychology among Asian clients is briefly discussed. 2011 APA, all rights reserved

  1. Position-Sensitive Detector with Depth-of-Interaction Determination for Small Animal PET

    CERN Document Server

    Fedorov, A; Kholmetsky, A L; Korzhik, M V; Lecoq, P; Lobko, A S; Missevitch, O V; Tkatchev, A

    2002-01-01

    Crystal arrays made of LSO and LuAP crystals 2x2x10 mm pixels were manufactured for evaluation of detector with depth-of-interaction (DOI) determination capability intended for small animal positron emission tomograph. Position-sensitive LSO/LuAP phoswich DOI detector based on crystal 8x8 arrays and HAMAMATSU R5900-00-M64 position-sensitive multi-anode photomultiplier tube was developed and evaluated. Time resolution was found to be not worse than 1.0 ns FWHM for both layers, and spatial resolution mean value was 1.5 mm FWHM for the center of field-of-view.

  2. Detecting positive quadrant dependence and positive function dependence

    NARCIS (Netherlands)

    Janic-Wróblewska, A.; Kallenberg, W.C.M.; Ledwina, T.

    2004-01-01

    There is a lot of interest in positive dependence going beyond linear correlation. In this paper three new rank tests for testing independence against positive dependence are introduced. The first one is directed on positive quadrant dependence, the second and third one concentrate on positive

  3. Detecting positive quadrant dependence and positive function dependence

    NARCIS (Netherlands)

    Janic-Wróblewska, A.; Kallenberg, W.C.M.; Ledwina, T.

    2003-01-01

    There is a lot of interest in positive dependence going beyond linear correlation. In this paper three new rank tests for testing independence against positive dependence are introduced. The first one is directed on positive quadrant dependence, the second and third one concentrate on positive

  4. Effect of Anode Dielectric Coating on Hall Thruster Operation

    International Nuclear Information System (INIS)

    Dorf, L.; Raitses, Y.; Fisch, N.J.; Semenov, V.

    2003-01-01

    An interesting phenomenon observed in the near-anode region of a Hall thruster is that the anode fall changes from positive to negative upon removal of the dielectric coating, which is produced on the anode surface during the normal course of Hall thruster operation. The anode fall might affect the thruster lifetime and acceleration efficiency. The effect of the anode coating on the anode fall is studied experimentally using both biased and emissive probes. Measurements of discharge current oscillations indicate that thruster operation is more stable with the coated anode

  5. Relationship of condylar position to disc position and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Incesu, L.; Taskaya-Yilmaz, N. E-mail: nergizy@omu.edu.tr; Oeguetcen-Toller, M.; Uzun, E

    2004-09-01

    Introduction/objective: The purpose of this study was to assess whether condylar position, as depicted by magnetic resonance imaging, was an indicator of disc morphology and position. Methods and material: One hundred and twenty two TMJs of 61 patients with temporomandibular joint disorder were examined. Condylar position, disc deformity and degree of anterior disc displacement were evaluated by using magnetic resonance imaging. Results and discussion: Posterior condyle position was found to be the main feature of temporomandibular joints with slight and moderate anterior disc displacement. No statistical significance was found between the condylar position, and reducing and nonreducing disc positions. On the other hand, superior disc position was found to be statistically significant for centric condylar position. Conclusion: It was concluded that posterior condyle position could indicate anterior disc displacement whereas there was no relation between the position of condyle and the disc deformity.

  6. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  7. Microbial community composition is unaffected by anode potential

    KAUST Repository

    Zhu, Xiuping

    2014-01-21

    There is great controversy on how different set anode potentials affect the performance of a bioelectrochemical system (BES). It is often reported that more positive potentials improve acclimation and performance of exoelectrogenic biofilms, and alter microbial community structure, while in other studies relatively more negative potentials were needed to achieve higher current densities. To address this issue, the biomass, electroactivity, and community structure of anodic biofilms were examined over a wide range of set anode potentials (-0.25, -0.09, 0.21, 0.51, and 0.81 V vs a standard hydrogen electrode, SHE) in single-chamber microbial electrolysis cells. Maximum currents produced using a wastewater inoculum increased with anode potentials in the range of -0.25 to 0.21 V, but decreased at 0.51 and 0.81 V. The maximum currents were positively correlated with increasing biofilm biomass. Pyrosequencing indicated biofilm communities were all similar and dominated by bacteria most similar to Geobacter sulfurreducens. Differences in anode performance with various set potentials suggest that the exoelectrogenic communities self-regulate their exocellular electron transfer pathways to adapt to different anode potentials. © 2013 American Chemical Society.

  8. Microbial community composition is unaffected by anode potential

    KAUST Repository

    Zhu, Xiuping; Yates, Matthew D.; Hatzell, Marta C.; Rao, Hari Ananda; Saikaly, Pascal; Logan, Bruce E.

    2014-01-01

    There is great controversy on how different set anode potentials affect the performance of a bioelectrochemical system (BES). It is often reported that more positive potentials improve acclimation and performance of exoelectrogenic biofilms, and alter microbial community structure, while in other studies relatively more negative potentials were needed to achieve higher current densities. To address this issue, the biomass, electroactivity, and community structure of anodic biofilms were examined over a wide range of set anode potentials (-0.25, -0.09, 0.21, 0.51, and 0.81 V vs a standard hydrogen electrode, SHE) in single-chamber microbial electrolysis cells. Maximum currents produced using a wastewater inoculum increased with anode potentials in the range of -0.25 to 0.21 V, but decreased at 0.51 and 0.81 V. The maximum currents were positively correlated with increasing biofilm biomass. Pyrosequencing indicated biofilm communities were all similar and dominated by bacteria most similar to Geobacter sulfurreducens. Differences in anode performance with various set potentials suggest that the exoelectrogenic communities self-regulate their exocellular electron transfer pathways to adapt to different anode potentials. © 2013 American Chemical Society.

  9. Positioning consumption

    DEFF Research Database (Denmark)

    Halkier, Bente; Keller, Margit

    2014-01-01

    positionings emerges based on empirical examples of research in parent–children consumption. Positionings are flexible discursive fixations of the relationship between the performances of the practitioner, other practitioners, media discourse and consumption activities. The basic positioning types...... are the practice maintenance and the practice change position, with different sorts of adapting in between. Media discourse can become a resource for a resistant position against social control or for an appropriating position in favour of space for action. Regardless of the current relation to a particular media......This article analyses the ways in which media discourses become a part of contested consumption activities. We apply a positioning perspective with practice theory to focus on how practitioners relate to media discourse as a symbolic resource in their everyday practices. A typology of performance...

  10. Detection of cosmic ray tracks using scintillating fibers and position sensitive multi-anode photomultipliers

    International Nuclear Information System (INIS)

    Atac, M.; Streets, J.; Wilcer, N.

    1998-02-01

    This experiment demonstrates detection of cosmic ray tracks by using Scintillating fiber planes and multi-anode photomultipliers (MA-PMTs). In a laboratory like this, cosmic rays provide a natural source of high-energy charged particles which can be detected with high efficiency and with nanosecond time resolution

  11. Investigation of the Effects of Cathode Flow Fraction and Position on the Performance and Operation of the High Voltage Hall Accelerator

    Science.gov (United States)

    Kamhawi, Hani; Huang, Wensheng; Haag, Thomas

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Science Mission Directorate In- Space Propulsion Technology office is sponsoring NASA Glenn Research Center (GRC) to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. Tests were performed within NASA GRC Vacuum Facility 5 at background pressure levels that were six times lower than what has previously been attained in other vacuum facilities. A study was conducted to assess the impact of varying the cathode-to-anode flow fraction and cathode position on the performance and operational characteristics of the High Voltage Hall Accelerator (HiVHAc) thruster. In addition, the impact of injecting additional xenon propellant in the vicinity of the cathode was also assessed. Cathode-to-anode flow fraction sensitivity tests were performed for power levels between 1.0 and 3.9 kW. It was found that varying the cathode flow fraction from 5 to approximately 10% of the anode flow resulted in the cathode-to-ground voltage becoming more positive. For an operating condition of 3.8 kW and 500 V, varying the cathode position from a distance of closest approach to 600 mm away did not result in any substantial variation in thrust but resulted in the cathode-to-ground changing from -17 to -4 V. The change in the cathode-to-ground voltage along with visual observations indicated a change in how the cathode plume was coupling to the thruster discharge. Finally, the injection of secondary xenon flow in the vicinity of the cathode had an impact similar to increasing the cathode-to-anode flow fraction, where the cathode-to-ground voltage became more positive and discharge current and thrust increased slightly. Future tests of the HiVHAc thruster are planned with a centrally mounted cathode in order to further assess the impact of cathode position on thruster performance.

  12. Optimal Set Anode Potentials Vary in Bioelectrochemical Systems

    KAUST Repository

    Wagner, Rachel C.

    2010-08-15

    In bioelectrochemical systems (BESs), the anode potential can be set to a fixed voltage using a potentiostat, but there is no accepted method for defining an optimal potential. Microbes can theoretically gain more energy by reducing a terminal electron acceptor with a more positive potential, for example oxygen compared to nitrate. Therefore, more positive anode potentials should allow microbes to gain more energy per electron transferred than a lower potential, but this can only occur if the microbe has metabolic pathways capable of capturing the available energy. Our review of the literature shows that there is a general trend of improved performance using more positive potentials, but there are several notable cases where biofilm growth and current generation improved or only occurred at more negative potentials. This suggests that even with diverse microbial communities, it is primarily the potential of the terminal respiratory proteins used by certain exoelectrogenic bacteria, and to a lesser extent the anode potential, that determines the optimal growth conditions in the reactor. Our analysis suggests that additional bioelectrochemical investigations of both pure and mixed cultures, over a wide range of potentials, are needed to better understand how to set and evaluate optimal anode potentials for improving BES performance. © 2010 American Chemical Society.

  13. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  14. The Role of Positive Emotions in Positive Psychology: The Broaden-and-Build Theory of Positive Emotions.

    Science.gov (United States)

    Fredrickson, Barbara L.

    2001-01-01

    Describes the broaden-and-build theory of positive emotions, situating it within the field of positive psychology. The theory posits that experiences of positive emotions broaden people's momentary thought-action repertoires, which in turn build their enduring personal resources (physical, intellectual, social, and psychological). Reviews…

  15. Ubiquitous positioning

    CERN Document Server

    Mannings, Robin

    2008-01-01

    This groundbreaking resource offers a practical, in-depth understanding of Ubiquitous Positioning - positioning systems that identify the location and position of people, vehicles and objects in time and space in the digitized networked economy. The future and growth of ubiquitous positioning will be fueled by the convergence of many other areas of technology, from mobile telematics, Internet technology, and location systems, to sensing systems, geographic information systems, and the semantic web. This first-of-its-kind volume explores ubiquitous positioning from a convergence perspective, of

  16. A Sleep Position Trainer for positional sleep apnea

    DEFF Research Database (Denmark)

    Laub, Rasmus R; Tønnesen, Philip; Jennum, Poul J

    2017-01-01

    We tested the effect of the Sleep Position Trainer, a vibrational device, for positional sleep apnea in an open, randomized controlled trial with 101 patients, where 52 patients were allocated to Sleep Position Trainer and 49 patients to a non-treatment control group for 2 months (Part 1). All...... patients were then followed as a cohort for a period of 6 months with use of the Sleep Position Trainer (Part 2). The participants were assessed with polygraphy at entry, and after 2 and 6 months. The mean apnea-hypopnea index supine was 35 per h (SD, 18) in the Sleep Position Trainer group and 38 per h...... (SD, 15) in the control group at entry. In a per protocol analysis, the mean total apnea-hypopnea index at entry and after 2 months in the Sleep Position Trainer group was 18 per h (SD, 10) and 10 per h (SD, 9; P

  17. Positive Psychology: Positive Emotions and Emotional Intelegence

    OpenAIRE

    Miloseva, Lence

    2008-01-01

    The paper focuses on the and emotional intelligence. We try to answer on some questions regarding the role which positive emotions have in our life’s. The broaden-and-build theory (Fredrickson, 1998; 2001) predicts that positive emotions are useful in several ways. They guide present behavior, by broadening one’s attention and cognition, setting the stage for creative, explorative, and innovative pursuits. As well, positive emotions build personal and social resources to help individuals achi...

  18. Anodic electrode position of cyanometallates as sample preparation for the determination of transition metals from water samples using X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Wundt, K.; Duschner, H.; Starke, K.

    1978-01-01

    The anodic separation of cyanometallates of propanol -2/Water mixtures at high electrical field strengths was developed as new technique for sample preparation. The optimization of the parameters of the system (high voltage applied, current density, separation time and composition of the solution) resulted in quantitative precipitation of the metallates of Fe, Co, Ni, Cu, Zn, Cd and Ag in homogeneous, thin and strong-adhering layer with mass densities of between 1 nmol cm -2 and 1 μmol cm -2 on high-purity aluminium foils. Metals not forming anionic complexes remain in solution with simualtaneous quantitative multielement separation. The described technique is part of a method to determine heavy metal traces in water samples. It comprises the nonspecific sorption on cation exchangers, the elution of the transition metals as cyanometallates, their electrode position on aluminium foil and the determination by X-ray fluorescence analysis. Model experiments illustrate the possible applications of the method. (orig.) [de

  19. Want Positive Behavior? Use Positive Language

    Science.gov (United States)

    Wood, Chip; Freeman-Loftis, Babs

    2012-01-01

    Positive adult language is the professional use of words and tone of voice to enable students to learn in an engaged, active way. This includes learning social skills. To guide children toward choosing and maintaining positive behaviors, adults need to carefully choose the words and tone of voice used when speaking to them. Learning to use…

  20. Navicular bone position determined by positional MRI: a reproducibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Philip; Nybing, Janus D. [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Johannsen, Finn E.; Stallknecht, Sandra E. [Copenhagen University Hospital Bispebjerg, Institute of Sports Medicine Copenhagen, Copenhagen, NV (Denmark); Hangaard, Stine; Hansen, Bjarke B. [Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark); Boesen, Mikael [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark)

    2016-02-15

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  1. Navicular bone position determined by positional MRI: a reproducibility study

    International Nuclear Information System (INIS)

    Hansen, Philip; Nybing, Janus D.; Johannsen, Finn E.; Stallknecht, Sandra E.; Hangaard, Stine; Hansen, Bjarke B.; Boesen, Mikael

    2016-01-01

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  2. Test of a position-sensitive photomultiplier for fast scintillating fiber detector read-out

    International Nuclear Information System (INIS)

    Baehr, J.; Hoffmann, B.; Luedecke, H.; Nahnhauer, R.; Pohl, M.; Roloff, H.E.

    1993-01-01

    A position-sensitive photomultiplier with 256 anode pixels has been used to read out scintillating fibers excited by light emitting diodes, electrons from a β-source and a 5 GeV electron beam. Measurements have been done within a magnetic field up to 0.6 T. Tracking and electromagnetic shower detection capabilities of a simple fiber detector have been studied. (orig.)

  3. Benign positional vertigo

    Science.gov (United States)

    Vertigo - positional; Benign paroxysmal positional vertigo; BPPV: dizziness- positional ... Benign positional vertigo is also called benign paroxysmal positional vertigo (BPPV). It is caused by a problem in the inner ear. ...

  4. Use of a multilayer printed circuit board as the position sensing electrode in an MWPC

    International Nuclear Information System (INIS)

    Barbosa, A.F.

    1995-01-01

    An X-ray gas position sensitive detector (PSD) is described. The detector makes use of a single electrode, the X and Y cathode, to sense the electric charge induced by the avalanches generated after the absorption of X-ray photons in a multiwire proportional counter (MWPC). Two-dimensional (2D) localization of photons is achieved by associating one delay line to each coordinate. The delay lines are directly coupled to the X and Y cathode, so that the propagation time of electric pulses can be related to the corresponding avalanche position. Since the position encoding does not involve wires, the anode is the only wire electrode present in the detector, used for collecting the avalanche electrons. (orig.)

  5. The Role of Positive Emotions in Positive Psychology: The Broaden-and-Build Theory of Positive Emotions

    OpenAIRE

    Fredrickson, Barbara L.

    2001-01-01

    In this article, the author describes a new theoretical perspective on positive emotions and situates this new perspective within the emerging field of positive psychology. The broaden-and-build theory posits that experiences of positive emotions broaden people's momentary thought-action repertoires, which in turn serves to build their enduring personal resources, ranging from physical and intellectual resources to social and psychological resources. Preliminary empirical evidence supporting ...

  6. Positioning performance of a maglev fine positioning system

    Energy Technology Data Exchange (ETDEWEB)

    Wronosky, J.B.; Smith, T.G.; Jordan, J.D.; Darnold, J.R.

    1996-12-01

    A wafer positioning system was recently developed by Sandia National Laboratories for an Extreme Ultraviolet Lithography (EUVL) research tool. The system, which utilizes a magnetically levitated fine stage to provide ultra-precise positioning in all six degrees of freedom, incorporates technological improvements resulting from four years of prototype development experience. System enhancements, implemented on a second generation design for an ARPA National Center for Advanced Information Component Manufacturing (NCAICM) project, introduced active structural control for the levitated structure of the system. Magnetic levitation (maglev) is emerging as an important technology for wafer positioning systems in advanced lithography applications. The advantages of maglev stem from the absence of physical contact. The resulting lack of friction enables accurate, fast positioning. Maglev systems are mechanically simple, accomplishing full six degree-of-freedom suspension and control with a minimum of moving parts. Power-efficient designs, which reduce the possibility of thermal distortion of the platen, are achievable. Manufacturing throughput will be improved in future systems with the addition of active structural control of the positioning stages. This paper describes the design, implementation, and functional capability of the maglev fine positioning system. Specifics regarding performance design goals and test results are presented.

  7. Positive Psychology

    Science.gov (United States)

    Peterson, Christopher

    2009-01-01

    Positive psychology is a deliberate correction to the focus of psychology on problems. Positive psychology does not deny the difficulties that people may experience but does suggest that sole attention to disorder leads to an incomplete view of the human condition. Positive psychologists concern themselves with four major topics: (1) positive…

  8. A novel compensation method for the anode gain non-uniformity of multi-anode photomultiplier tubes.

    Science.gov (United States)

    Lee, Chan Mi; Il Kwon, Sun; Ko, Guen Bae; Ito, Mikiko; Yoon, Hyun Suk; Lee, Dong Soo; Hong, Seong Jong; Lee, Jae Sung

    2012-01-07

    The position-sensitive multi-anode photomultiplier tube (MA-PMT) is widely used in high-resolution scintillation detectors. However, the anode gain nonuniformity of this device is a limiting factor that degrades the intrinsic performance of the detector module. The aim of this work was to develop a gain compensation method for the MA-PMT and evaluate the resulting enhancement in the performance of the detector. The method employs a circuit that is composed only of resistors and is placed between the MA-PMT and a resistive charge division network (RCN) used for position encoding. The goal of the circuit is to divide the output current from each anode, so the same current flows into the RCN regardless of the anode gain. The current division is controlled by the combination of a fixed-value series resistor with an output impedance that is much larger than the input impedance of the RCN, and a parallel resistor, which detours part of the current to ground. PSpice simulations of the compensation circuit and the RCN were performed to determine optimal values for the compensation resistors when used with Hamamatsu H8500 MAPMTs. The intrinsic characteristics of a detector module consisting of this MA-PMT and a lutetium-gadolinium-oxyorthosilicate (LGSO) crystal array were tested with and without the gain compensation method. In simulation, the average coefficient of variation and max/min ratio decreased from 15.7% to 2.7% and 2.0 to 1.2, respectively. In the flood map of the LGSO-H8500 detector, the uniformity of the photopeak position for individual crystals and the energy resolution were much improved. The feasibility of the method was shown by applying it to an octagonal prototype positron emission tomography scanner.

  9. Dynamic Characteristics of Positive Pulsed Dielectric Barrier Discharge for Ozone Generation in Air

    Science.gov (United States)

    Wei, Linsheng; Peng, Bangfa; Li, Ming; Zhang, Yafang; Hu, Zhaoji

    2016-02-01

    A comprehensive dynamic model consisting of 66 reactions and 24 species is developed to investigate the dynamic characteristics of ozone generation by positive pulsed dielectric barrier discharge (DBD) using parallel-plate reactor in air. The electron energy conservation equation is coupled to the electron continuity equation, the heavy species continuity equation, and Poisson's equation for a better description. The reliability of the model is experimentally confirmed. The model can be used to predict the temporal and spatial evolution of species, as well as streamer propagation. The simulation results show that electron density increases nearly exponentially in the direction to the anode at the electron avalanche. Streamer propagation velocity is about 5.26 × 104 m/s from anode to cathode in the simulated condition. The primary positive ion, negative ion, and excited species are O2+, O3- and O2(1Δg) in pulsed DBD in air, respectively. N2O has the largest density among nitrogen oxides. e and N2+ densities in the streamer head increase gradually to maximum values with the development of the streamer. Meanwhile, the O2+, O, O3, N2(A3Σ) and N2O densities reach maximum values in the vicinity of the anode. supported by National Natural Science Foundation of China (Nos. 51366012 and 11105067), Jiangxi Province Young Scientists (Jinggang Star) Cultivation Plan of China (No. 20133BCB23008), Natural Science Foundation of Jiangxi, China (No. 20151BAB206047) and Jiangxi Province Higher School Science and Technology Landing Plan of China (No. KJLD-14015)

  10. Variations of radiation intensity as a function of position in radiation field of a mammographic unit of 760 mm SID with Mo anode and 20 μm Mo added filter

    International Nuclear Information System (INIS)

    Noriah Jamal

    2001-01-01

    There are many effects that contribute to radiation field nonuniformity in mammography, including the heel effect and shorter source to image distance (SID), inverse square law and different photon path lengths through various attenuating media (the x-ray tube beryllium window, the added filter, the mirror, and the compression paddle) throughout the field. Variations of radiation intensity was investigated as a function of position in the radiation field (with compression paddle in place)of a mammographic unit in 760 mm SID with Mo anode and 20 μm Mo added filter. Reduction in radiation intensity along central axis of up to 19.40%, 19.13% and 19.34% were noted at 24, 26 and 28 kVp respectively. Radiation intensity also drops off to the left and right of the central axis. As a function of position in the field, we also found that the variations of optical density correlate well with the measured radiation intensity changes. (Author)

  11. Why victimology should stay positive: The ongoing need for positive victimology

    Directory of Open Access Journals (Sweden)

    Ronel Natti

    2015-01-01

    Full Text Available This paper presents the need for positive victimology and its unique contribution to victimology. Victimology presented a shift in attention and awareness in practice, research and theory, by focusing on victims of crime and of abuse of power, and on victims’ rights and victims’ services. Positive victimology indicates a more specified shift in attention and awareness, within the larger shift of victimology. This shift stands in line with positive psychology, positive criminology and the idea of victims’ victimology. It denotes an approach to provide the following, as much as possible: 1. A wide range of social responses to the victims and their victimization that victims can experience as positive, 2. Positive outcomes of healing and recovery for victims, and 3. Positive integration of victims. Within each of those, positive victimology suggests a pragmatic coordinated system that ranges from definitions of negative poles to those of positive ones. When moving towards the positive pole at any given coordinate, a sense of justice is an important factor that might reduce the impact of the harm. Support is also a crucial factor and at the very positive pole, stands human, inter-personal love.

  12. Multi-technology positioning

    CERN Document Server

    Lohan, Elena-Simona; Wymeersch, Henk; Seco-Granados, Gonzalo; Nykänen, Ossi

    2017-01-01

    This book provides an overview of positioning technologies, applications and services in a format accessible to a wide variety of readers. Readers who have always wanted to understand how satellite-based positioning, wireless network positioning, inertial navigation, and their combinations work will find great value in this book. Readers will also learn about the advantages and disadvantages of different positioning methods, their limitations and challenges. Cognitive positioning, adding the brain to determine which technologies to use at device runtime, is introduced as well. Coverage also includes the use of position information for Location Based Services (LBS), as well as context-aware positioning services, designed for better user experience. • Brings understanding of positioning technology to readers from a variety of disciplines • Reviews multiple techniques, providing insight on the pros, cons and challenges related to each • Designed to be a tutorial on basic principles, avoiding unnecessary de...

  13. A Vision/Inertia Integrated Positioning Method Using Position and Orientation Matching

    Directory of Open Access Journals (Sweden)

    Xiaoyue Zhang

    2017-01-01

    Full Text Available A vision/inertia integrated positioning method using position and orientation matching which can be adopted on intelligent vehicle such as automated guided vehicle (AGV and mobile robot is proposed in this work. The method is introduced firstly. Landmarks are placed into the navigation field and camera and inertial measurement unit (IMU are installed on the vehicle. Vision processor calculates the azimuth and position information from the pictures which include artificial landmarks with the known direction and position. Inertial navigation system (INS calculates the azimuth and position of vehicle in real time and the calculated pixel position of landmark can be computed from the INS output position. Then the needed mathematical models are established and integrated navigation is implemented by Kalman filter with the observation of azimuth and the calculated pixel position of landmark. Navigation errors and IMU errors are estimated and compensated in real time so that high precision navigation results can be got. Finally, simulation and test are performed, respectively. Both simulation and test results prove that this vision/inertia integrated positioning method using position and orientation matching has feasibility and it can achieve centimeter-level autonomic continuous navigation.

  14. Performance of a plasma opening switch in positive polarity on Gamble I using flashboard plasma sources

    International Nuclear Information System (INIS)

    Renk, T.J.

    1995-01-01

    The successful development of the Plasma Opening Switch (POS) for inductive storage applications has been largely confined to negative polarity operation. Some models of POS behavior suggest that this is because in a positive polarity coaxial configuration, the weaker magnetic field at the cathode position retards the switch opening process. This article describes experiments in which both conductor radii in the POS region were significantly reduced. Anode- and cathode-side current monitors indicate that voltages greater than open-circuit are generated at the POS position, but there is a significant amount of electron flow out of the POS, depending upon load impedance. Flow impedance analysis indicates that a relatively small gap appears in the POS plasma after switch opening. Switch performance is also compared between flashboard and carbon gun plasma sources, with the latter operated both in positive and negative polarity

  15. Position Information

    Data.gov (United States)

    Social Security Administration — The Position Information Data Asset provides the ability to search for active SSA position descriptions using various search criteria. An individual may search by PD...

  16. Position sensitive detector for X-ray photons

    International Nuclear Information System (INIS)

    Barbosa, A.F.

    1988-01-01

    This work reports the theoretical basis and the details of the construction process, characterization and application of gas X-ray position sensitive detectors. The unidimensional detector consists of a gas camera (argon and CH 4 ), a metallic anode, a cathode and a delay line. Details of the construction process are given in order to allow the reproduction of the detector. It has been characterized by measuring its spatial resolution, homogeneity and linerity. The built linear detector has been used to obtain diffraction diagrams from polycrystalline silicon, C 23 H 48 paraffin and glassy carbon. These diagrams have been compared with those obtained under equivalent conditions with a conventional proportional detector by the step scanning method. It has been shown that the detector provides diffraction diagrams of equivalent quality to those obtained by the step scanning method, in appreciably lower time intervals. (author) [pt

  17. Cellular automaton-based position sensitive detector equalization

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, Nestor [Grupo de Diseno de Sistemas Digitales, Instituto de Aplicaciones de las Tecnologias de la Informacion y de las Comunicaciones Avanzadas, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)], E-mail: nesferjo@upvnet.upv.es; Herrero, V.; Cerda, J.; Lerche, C.W.; Colom, R.J.; Gadea, R.; Martinez, J.D.; Monzo, J.M.; Mateo, F.; Sebastia, A.; Benlloch, J.M. [Grupo de Diseno de Sistemas Digitales, Instituto de Aplicaciones de las Tecnologias de la Informacion y de las Comunicaciones Avanzadas, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2009-06-01

    Indirect position detectors based on scintillator crystals lack of spacial uniformity in their response. This happens due to crystal inhomogeneities and gain differences among the photomultiplier anodes. In order to solve this, PESIC, an integrated front-end for multianode photomultiplier based nuclear imaging devices was created. One of its main features is the digitally programmable gain adjustment for every photomultiplier output. On another front, cellular automata have been proved to be a useful method for dynamic system modeling. In this paper, a cellular automaton which emulates the behavior of the scintillator crystal, the photomultiplier and the front-end is introduced. Thanks to this model, an automatic energy-based calibration of the detector can be done by configuring the cellular automaton with experimental data and making it evolve up to an stable state. This can be useful as a precalibration method of the detector.

  18. Cellular automaton-based position sensitive detector equalization

    International Nuclear Information System (INIS)

    Ferrando, Nestor; Herrero, V.; Cerda, J.; Lerche, C.W.; Colom, R.J.; Gadea, R.; Martinez, J.D.; Monzo, J.M.; Mateo, F.; Sebastia, A.; Benlloch, J.M.

    2009-01-01

    Indirect position detectors based on scintillator crystals lack of spacial uniformity in their response. This happens due to crystal inhomogeneities and gain differences among the photomultiplier anodes. In order to solve this, PESIC, an integrated front-end for multianode photomultiplier based nuclear imaging devices was created. One of its main features is the digitally programmable gain adjustment for every photomultiplier output. On another front, cellular automata have been proved to be a useful method for dynamic system modeling. In this paper, a cellular automaton which emulates the behavior of the scintillator crystal, the photomultiplier and the front-end is introduced. Thanks to this model, an automatic energy-based calibration of the detector can be done by configuring the cellular automaton with experimental data and making it evolve up to an stable state. This can be useful as a precalibration method of the detector.

  19. Measurement of gas temperature and OH density in the afterglow of pulsed positive corona discharge

    International Nuclear Information System (INIS)

    Ono, Ryo; Oda, Tetsuji

    2008-01-01

    The gas temperature and OH density in the afterglow of pulsed positive corona discharge are measured using the laser-induced predissociation fluorescence (LIPF) of OH radicals. Discharge occurs in a 13 mm point-to-plane gap in an atmospheric-pressure H 2 O(2.8%)/O 2 (2.0%)/N 2 mixture. The temperature measurement shows that (i) the temperature increases after discharge and (ii) the temperature near the anode tip (within 1 mm from the anode tip) is much higher than that of the rest of the discharge volume. Near the anode tip, the temperature increases from 500 K (t = 0 μs) to 1100 K (t = 20 μs), where t is the postdischarge time, while it increases from 400 K (t = 0 μs) to 700 K (t = 100 μs) in the rest of the discharge volume away from the anode tip. This temperature difference between the two volumes (near and far from the anode tip) causes a difference in the decay rate of OH density: OH density near the anode tip decays approximately 10 times slower than that far from the tip. The spatial distribution of OH density shows good agreement with that of the secondary streamer luminous intensity. This shows that OH radicals are mainly produced in the secondary streamer, not in the primary one

  20. PerPos: a Translucent Positioning Middleware Supporting Adaptation of Internal Positioning Processes

    DEFF Research Database (Denmark)

    Jensen, Jakob Langdal; Schougaard, Kari Rye; Kjærgaard, Mikkel Baun

    2010-01-01

    of application specific features that can be applied to the internal position processing of the middleware. To evaluate these capabilities we extend the internal position processing of the middleware with functionality supporting probabilistic position tracking and strategies for minimization of the energy......A positioning middleware benefits the development of location aware applications. Traditionally, positioning middleware provides position transparency in the sense that it hides low-level details. However, many applications require access to specific details of the usually hidden positioning...

  1. Positive Psychology and Positive Education: Old Wine in New Bottles?

    Science.gov (United States)

    Kristjansson, Kristjan

    2012-01-01

    The recently fashionable theories of positive psychology have educational ramifications at virtually every level of engagement, culminating in the model of positive education. In this critical review, I scrutinize positive education as a potential theory in educational psychology. Special attention is given to conceptual controversies and…

  2. Position automatic determination technology

    International Nuclear Information System (INIS)

    1985-10-01

    This book tells of method of position determination and characteristic, control method of position determination and point of design, point of sensor choice for position detector, position determination of digital control system, application of clutch break in high frequency position determination, automation technique of position determination, position determination by electromagnetic clutch and break, air cylinder, cam and solenoid, stop position control of automatic guide vehicle, stacker crane and automatic transfer control.

  3. Positive Eigenvalues of Generalized Words in Two Hermitian Positive Definite Matrices

    OpenAIRE

    Hillar, Christopher; Johnson, Charles R.

    2005-01-01

    We define a word in two positive definite (complex Hermitian) matrices $A$ and $B$ as a finite product of real powers of $A$ and $B$. The question of which words have only positive eigenvalues is addressed. This question was raised some time ago in connection with a long-standing problem in theoretical physics, and it was previously approached by the authors for words in two real positive definite matrices with positive integral exponents. A large class of words that do guarantee positive eig...

  4. Simultaneous resolution of spectral and temporal properties of UV and visible fluorescence using single-photon counting with a position-sensitive detector

    International Nuclear Information System (INIS)

    Kelly, L.A.; Trunk, J.G.; Polewski, K.; Sutherland, J.C.

    1995-01-01

    A new fluorescence spectrometer has been assembled at the U9B beamline of the National Synchrotron Light Source to allow simultaneous multiwavelength and time-resolved fluorescence detection, as well as spatial imaging of the sample fluorescence. The spectrometer employs monochromatized, tunable UV and visible excitation light from a synchrotron bending magnet and an imaging spectrograph equipped with a single-photon sensitive emission detector. The detector is comprised of microchannel plates in series, with a resistive anode for encoding the position of the photon-derived current. The centroid position of the photon-induced electron cascade is derived in a position analyzer from the four signals measured at the corners of the resistive anode. Spectral information is obtained by dispersing the fluorescence spectrum across one dimension of the detector photocathode. Timing information is obtained by monitoring the voltage divider circuit at the last MCP detector. The signal from the MCP is used as a ''start'' signal to perform a time-correlated single photon counting experiment. The analog signal representing the position, and hence wavelength, is digitized concomitantly with the start/stop time difference and stored in the two-dimensional histogramming memory of a multiparameter analyzer

  5. Face-down positioning versus non-supine positioning in macular hole surgery

    DEFF Research Database (Denmark)

    Alberti, Mark; Dornonville de la Cour, Morten

    2015-01-01

    AIM: To evaluate the full thickness macular hole (FTMH) closure rate in patients positioning non-supine (NSP) compared with patients positioning face-down (FDP). METHODS: We retrospectively reviewed two FTMH case series-postoperative positioning was FDP and NSP, respectively. All eyes were...... group fully complied with the recommended positioning protocol. CONCLUSIONS: Results from consistent FTMH repair indicate similar anatomical success rates in FDP and NSP groups, suggesting that FDP is unnecessary. Objective monitoring of positioning would be beneficial in future FTMH studies to be able...

  6. Patterned titania nanostructures produced by electrochemical anodization of titanium sheet

    Science.gov (United States)

    Dong, Junzhe; Ariyanti, Dessy; Gao, Wei; Niu, Zhenjiang; Weil, Emeline

    2017-07-01

    A two-step anodization method has been used to produce patterned arrays of TiO2 on the surface of Ti sheet. Hexagonal ripples were created on Ti substrate after removing the TiO2 layer produced by first-step anodization. The shallow concaves were served as an ideal position for the subsequent step anodization due to their low electrical resistance, resulting in novel hierarchical nanostructures with small pits inside the original ripples. The mechanism of morphology evolution during patterned anodization was studied through changing the anodizing voltages and duration time. This work provides a new idea for controlling nanostructures and thus tailoring the photocatalytic property and wettability of anodic TiO2.

  7. Analysis and design of double-anode magnetron injection gun

    International Nuclear Information System (INIS)

    Yang Tie; Niu Xinjian; Liu Yinghui

    2013-01-01

    Based on electro-optical theory and adiabatic compression theory, a double-anode magnetic injection gun for TE 34,19 , 170 GHz gyrotron was analyzed and designed with EGUN software. Concerning with the factors such as positions of anode and magnetic field distance between anodes, we obtained the result that the velocity ratio of electron beam approximated 1.3, and the velocity spread was under 3%. Furthermore, we found that electron beam was sensitive with these factors, such as that the velocity ratio decreased when the distance between anodes increased, while the velocity spread decreased first and then increased. The double-anode magnetic injection gun is employed in the experiments of gyrotron. (authors)

  8. Researcher positioning

    DEFF Research Database (Denmark)

    Mørck, Line Lerche; Khawaja, Iram

    2009-01-01

    abstract  This article focuses on the complex and multi-layered process of researcher positioning, specifically in relation to the politically sensitive study of marginalised and ‘othered' groups such as Muslims living in Denmark. We discuss the impact of different ethnic, religious and racial...... political and personal involvement by the researcher, which challenges traditional perspectives on research and researcher positioning. A key point in this regard is the importance of constant awareness of and reflection on the multiple ways in which one's positioning as a researcher influences the research...

  9. CONTEMPLATIVE POSITIVE PSYCHOLOGY: INTRODUCING MINDFULNESS INTO POSITIVE PSYCHOLOGY

    Directory of Open Access Journals (Sweden)

    Ausiàs Cebolla

    2017-01-01

    Full Text Available Although mindfulness is included in many positive psychology manuals as a “positive” technique, the implications of its use have scarcely been developed and the relationship between mindfulness and human well-being has barely been researched. Analyzing the main strengths of the two fields, the possibilities for their integration and the potential contradictions between their messages is essential in order to establish connections. Mindfulness is more than a meditation technique. It has implicit within it a set of values and ethical conditions that coincide to a great extent with the proposed assumptions from positive psychology, such as the development of kindness, compassion, and positive emotions. The aim of this paper is to present, on the one hand, the commonalities and similarities, and on the other, the differences between mindfulness and positive psychology. We also present the main studies that have investigated the role of mindfulness and contemplative practices on human well-being. Finally future research will be discussed and intervention suggested in order to bring the two proposals together.

  10. Modulating the Physical and Electronic Properties over Positional Isomerism: The Dispirofluorene-Dihydroindacenodithiophene (DSF-IDT) Family.

    Science.gov (United States)

    Peltier, Jean-David; Heinrich, Benoît; Donnio, Bertrand; Jeannin, Olivier; Rault-Berthelot, Joëlle; Poriel, Cyril

    2017-12-06

    We report the first studies on the intrinsic properties of a meta-substituted dihydroindacenodithienyl fragment and more generally the strong impact of positional isomerism on dihydroindacenodithiophene derivatives. The influence of the para and meta linkages has notably been highlighted not only for the electronic properties in solution (electrochemical properties, anodic polymerization, HOMO/LUMO energy levels, optical transitions, fluorescence spectra) but also on the physical properties in the solid state (molecular organization, crystallinity, and phase transitions). The positional isomerism hence appears to be a very efficient tool to drastically tune the properties of dihydroindacenodithiophene derivatives. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Position sensitive photon detectors for nuclear physics, particle physics and healthcare applications

    International Nuclear Information System (INIS)

    Seitz, B

    2012-01-01

    Modern experiments in hadronic physics require detector systems capable of identifying and reconstructing all final-state particles and their momentum vectors. Imaging Cherenkov counters (RICH and DIRC) are frequently employed in nuclear and particle physics experiments. These detectors require high-rate, single-photon capable light detection system with sufficient granularity and position resolution. Several candidate systems are available, ranging from multi-anode photomultiplier tubes to micro-channel plate systems to silicon photomultipliers. Each of these detection solutions has particular advantages and disadvantages. Detailed studies of rate dependence, cross-talk, time-resolution and position resolution for a range of available photon detection solutions are presented. These properties make these photon detection systems ideal for radionuclide imaging applications. Cherenkov radiation can also be used for medical imaging applications. Two different applications using the Cherenkov effect for radionuclide imaging will be reviewed.

  12. Evaluation of the anode heel effect on the testes dose during pelvic radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-05-01

    Full Text Available Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male patients undergoing pelvic radiography. Methods: This is a cross-sectional study, conducted at one of the teaching hospitals of Ahvaz, Jundishapur University of Medical Science Ahvaz, Iran, from September 2015 to March 2016. In order to measure the profile of radiation intensity variation, 13 paired sets of high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD aligned on the cathode-anode central axis upon the table and then irradiated using routine exposure parameters. The anode of X-ray tube was positioned toward the feet for 40 patients and toward the head for 39 patients undergoing pelvic radiography. For measure the entrance skin dose (ESD, 8 TLD chips were located on the central point of the radiation field and 5 TLDs were located on the testes position to measure the dose received. Results: Radiation intensity profile showed that radiation intensity decrease from the cathode to the anode side. Discrepancy of radiation intensity on central axis of cathode-anode was calculated about 35%. The radiation dose received by the testes was 26.74% lower for patients the anode directed toward the feet, compared to the patients in which the anode directed toward the head (FTC: 1.260±0.296 mGy, FTA: 0.923±0.167 mGy, P<0.05. There was no meaningful difference for the measured ESD of pelvis between two groups of patients (FTC: 1.256±0.315 mGy, FTA: 1.195±0.205 mGy, P=0.788. Conclusion: In pelvic radiography, positioning of testes directed to the anode of X-ray tube can decrease the receive dose.

  13. Asymmetric battery having a semi-solid cathode and high energy density anode

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Taison; Chiang, Yet-Ming; Ota, Naoki; Wilder, Throop; Duduta, Mihai

    2017-11-28

    Embodiments described herein relate generally to devices, systems and methods of producing high energy density batteries having a semi-solid cathode that is thicker than the anode. An electrochemical cell can include a positive electrode current collector, a negative electrode current collector and an ion-permeable membrane disposed between the positive electrode current collector and the negative electrode current collector. The ion-permeable membrane is spaced a first distance from the positive electrode current collector and at least partially defines a positive electroactive zone. The ion-permeable membrane is spaced a second distance from the negative electrode current collector and at least partially defines a negative electroactive zone. The second distance is less than the first distance. A semi-solid cathode that includes a suspension of an active material and a conductive material in a non-aqueous liquid electrolyte is disposed in the positive electroactive zone, and an anode is disposed in the negative electroactive zone.

  14. Induction position for spinal anaesthesia: Sitting versus lateral position

    International Nuclear Information System (INIS)

    Shahzad, K.; Afshan, G.

    2013-01-01

    Objective: To compare the effect of induction position on block characteristics (sensory and motor nerves) and haemodynamic stability in elderly patients with isobaric bupivacaine. Patient comfort was also looked at. Methods: The randomized single blinded study was conducted at the Aga Khan University Hospital, Karachi, from September 2007 to August 2008. A total of 70 patients aged >60 years of both genders were included. Spinal anaesthesia was performed either in sitting or lateral position according to random allocation. Assessments of sensory, motor block and heart rate, systolic and diastolic blood pressure were recorded for 20 minutes. SPSS 16 was used for statistical analysis. Results: There was no significant difference for haemodynamic variables heart rate, systolic and diastolic blood pressure. The onset of anaesthesia was faster in the sitting group (4.5 minutes vs 5.4 minutes). The motor block characteristics were similar in both the groups. The majority of patients who reported 'very comfortable' for induction position belonged to the lateral group. Conclusion: Both sitting and lateral positions have similar effects on sensory and motor blockade and haemodynamic stability. However, patients generally found lateral position very comfortable. (author)

  15. POSITIONING STRATEGIES DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Shakhshir Ghassan

    2014-07-01

    Full Text Available The positioning strategy has suffered serious changes in the last few decades, being influenced by the rapid development of competition and the growing focus on specific traits belonging to the market, to the consumer or to the product. The purpose of this paper is to present the developments of theoretical positioning strategies and the orientation from more simple, product oriented strategies, to ones more oriented towards the client and with a briefer period of time. The world is moving in a much faster pace than in the past, thanks to communication development so companies are obliged to adopt more specific strategies in order for them to be effective. This essay represents a literary review presenting a documentary research within the scientific articles and strategy and positioning books. The paper begins with the analysis of company strategies and the marketing strategies in general. The first author to group the product positioning strategies is Porter with his three generic strategies. Following the development of brands and because of the lack of competitiveness in the simple generic positioning strategies, this paper has also presented the newer positioning strategies proposed by Kotler, Treacy & Wiersema, and also more complex ones such as Bowman's Strategy Clock and Blankson and Kalafatis positioning strategy based on the type of the consumer. The fast expansion of local brands in all categories has led to mistakes in positioning strategies, categories also presented in the current essay. The results of this study show that new positioning strategies are more and more based on the consumer and market segments and on the product specification - which have also evolved in the last decades. Adaptability to fast changes in the competitive market will represent the future positioning strategies.

  16. Contextual positive psychology: Policy recommendations for implementing positive psychology into schools.

    Directory of Open Access Journals (Sweden)

    Joseph Ciarrochi

    2016-10-01

    Full Text Available There has been a rapid growth in positive psychology, a research and intervention approach that focuses on promoting optimal functioning and well-being. Positive psychology interventions are now making their way into classrooms all over the world. However, positive psychology has been criticized for being decontextualized and coercive, and for putting an excessive emphasis on positive states, whilst failing to adequately consider negative experiences. Given this, how should policy be used to regulate and evaluate these interventions? We review evidence that suggests these criticisms may be valid, but only for those interventions that focus almost exclusively on changing the content of people’s inner experience (e.g., make it more positive and personality (improving character strength, and overemphasize the idea that inner experience causes action. We describe a contextualized form of positive psychology that not only deals with the criticisms, but also has clear policy implications for how to best implement and evaluate positive education programs so that they do not do more harm than good.

  17. Study of a high-resolution, 3-D positioning cadmium zinc telluride detector for PET

    Science.gov (United States)

    Gu, Y; Matteson, J L; Skelton, R T; Deal, A C; Stephan, E A; Duttweiler, F; Gasaway, T M; Levin, C S

    2011-01-01

    This paper investigates the performance of 1 mm resolution Cadmium Zinc Telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3-D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06±0.39% at 511 keV throughout most the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44±0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78±0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes – as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system. PMID:21335649

  18. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

    Science.gov (United States)

    Gu, Y; Matteson, J L; Skelton, R T; Deal, A C; Stephan, E A; Duttweiler, F; Gasaway, T M; Levin, C S

    2011-03-21

    This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06 ± 0.39% at 511 keV throughout most of the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44 ± 0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78 ± 0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes-as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system.

  19. Flat Panel PMT: advances in position sensitive photodetection

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Trotta, C.; Cinti, M.N.; Bennati, P.; Trotta, G.; Iurlaro, G.; Montani, L.; Ridolfi, S.; Cusanno, F.; Garibaldi, F.

    2003-01-01

    Over the last ten years there was being a strong advancement in photodetection. Different application fields are involved in their use in particular high energy physics, astrophysics and nuclear medicine. They usually work by coupling a scintillation crystal and more recent scintillation arrays with pixel size as small as 0.5 mm. PSPMT represents today the most ready technology for photodetection with large detection areas and very high spatial resolution. Flat panel PMT represents the last technological advancement. Its dimension is 50x50 mm 2 with a narrow peripheral dead zone (0.5 mm final goal). Its compactness allow to assemble different modules closely packed, achieving large detection areas with an effective active area of 97%. In this paper we analyze the imaging performances of PSPMT by coupling two scintillation arrays and by light spot scanning of photocathode to evaluate the linearity position response, spatial resolution and uniformity gain response as a function of light distribution spread and the number of photoelectrons generated on photocathode. The results point out a very narrow PMT intrinsic charge spread and low cross-talk between anodes. Energy resolution and spatial resolution show a good linearity with DRF variation. An unexpected intra-anode gain variation is carried out. In this paper we present the results obtained with this PSPMT regarding imaging performances principally addressed to nuclear medicine application

  20. A Study of a Striated Positive Column after Ethanol Impurity Injection in an Air DC Glow Discharge

    Science.gov (United States)

    Berzak, Laura; Post Zwicker, Andrew

    2003-04-01

    In a glow discharge when ethanol (CH3CH2OH) was injected, a series of atypical striations formed through the positive column. When the pressure decreased as the ethanol evaporated and was evacuated by the vacuum pump, this behavior decayed away until only an anode glow or normal discharge remained. Varying interelectrode spacings and quantities of ethanol yielded similar patterns. The typical evolution as the pressure decreased consisted of a visible traveling wave traveling from the anode to the cathode followed by numerous, thin ( 1.6 mm) striations evenly spaced down the entire length of the positive column. These, shifted back toward the anode and transformed into bent striations with the tip of the 'V' pointing toward the cathode, and finally, the 'V' striations grouped into fours and took on the appearance of beats. The unusual 'V' striations may be due in part to a contraction of the column, causing the equipotential surfaces to shift from smooth convex to the observed striation shape. The conditions for this contraction effect include a nonlinearly increasing dependence of electron production rate on electron density and a bulk recombination rate higher than that at the tube walls. Visible emission spectra indicated the presence of carbon monoxide (CO), signifying that the striations are due to not only vibrational excitation of the ethanol molecule but also to decomposition and subsequent excitation of the decomposition products as well. One possible mechanism of decomposition is the formation of a radical cation from the ethanol molecule and the ensuing loss of a proton to yield formaldehyde; this then would follow an analogous decomposition to produce carbon monoxide. Thus, there may exist additional charged species which can then contribute to the unique observations. Further analysis, if possible, will include higher temporal resolution spectroscopy and a detailed model of the positive column under these specific conditions.

  1. Investigation of the Anode Attachment Process in Plasma Arc Cutting

    International Nuclear Information System (INIS)

    Eichler, Stefan; Schein, Jochen; Hussary, Nakhleh; Siewert, Erwan

    2014-01-01

    The anode attachment process in plasma arc cutting is still not well understood in spite of decades of industrial use. Previously, several approaches were made to analyze the attachment mechanisms including imaging, discharge current and voltage measurements as well as the use of thermocouples. In this paper a different approach is described to evaluate the attachment position. Six electrically separated water-cooled copper plates arranged in layers are used as an anode emulating a workpiece. The current through each layer is measured individually using current Hall sensors. The thus obtained information about the current distribution across each plate is used to deduce the anode attachment position inside the workpiece. This diagnostics allows a quick determination of the influence of process parameter variations like the cutting current, gas flow rate, cutting speed or the torch distance on the current distribution inside the workpiece. Using this setup, it is observed that no single attachment appears; the current is divided to flow through all anode segments. The torch distance and cutting speed proved to have the biggest influence on the anode current distribution. Comparison between measurements conducted with the new setup and an experiment using steel plates instead of copper plates is provided

  2. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  3. Position detector

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi.

    1985-01-01

    Purpose: To enable to detect the position of an moving object in a control rod position detector, stably in a digital manner at a high accuracy and free from the undesired effects of circumstantial conditions such as the reactor temperature. Constitution: Coils connected in parallel with each other are disposed along the passage of a moving object and variable resistors and relays are connected in series with each of the coils respectively. Light emitting diodes is connected in series with the contacts of the respective relays. The resistance value of the variable resistors are adjusted depending on the changes in the circumstantial conditions and temperature distribution upon carrying out the positional detection. When the object is inserted into a coils, the relevant relay is deenergized, by which the relay contacts are closed to light up the diode. In the same manner, as the object is successively inserted into the coils, the diodes are lighted-up successively thereby enabling highly accurate and stable positional detection in a digital manner, free from the undesired effects of the circumstantial conditions. (Horiuchi, T.)

  4. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  5. Multi-anode deep well radiation detector

    International Nuclear Information System (INIS)

    Rogers, A.H.; Sullivan, K.J.; Mansfield, G.R.

    1984-01-01

    An inner cylindrical cathode and outer cylindrical cathode are concentrically positioned about a vertical center axis. Vertical anode electrodes extend parallel to the center axis and are symmetrically arranged around the inter-cylinder space between the cathodes. The ends of the anode wires are supported by a pair of insulator rings and mounted near the top and bottom of the cathode cylinders. A collection voltage applied to each anode wire for establishing an inward radial E field to the inner cathode cylinder and an outward radial E field to the outer cathode cylinder. The anode-cathode assembly is mounted within a housing containing a conversion gas. A radioactive sample is inserted into the inner cathode which functions as a tubular, deep well radiation window between the sample environment and the conversion gas environment. A portion of the gamma radiations passing through the inter-cylinder region interact with the conversion gas to produce free electrons which are accelerated by the E fields and collected on the anode wires. The extremely small diameter of the anode wires intensifies the electric fields proximate each wire causing avalanche multiplication of the free electrons resulting in a detectable charge pulse. (author)

  6. Positive expectations encourage generalization from a positive intergroup interaction to outgroup attitudes.

    Science.gov (United States)

    Deegan, Matthew P; Hehman, Eric; Gaertner, Samuel L; Dovidio, John F

    2015-01-01

    The current research reveals that while positive expectations about an anticipated intergroup interaction encourage generalization of positive contact to outgroup attitudes, negative expectations restrict the effects of contact on outgroup attitudes. In Study 1, when Blacks and Whites interacted with positive expectations, interaction quality predicted outgroup attitudes to a greater degree than when groups interacted with negative expectations. When expectations (Studies 2 and 3) and the actual interaction quality (Study 4) were manipulated orthogonally, negative expectations about the interaction predicted negative outgroup attitudes, regardless of actual interaction quality. By contrast, participants holding positive expectations who experienced a positive interaction expressed positive outgroup attitudes, whereas when they experienced a negative interaction, they expressed outgroup attitudes as negative as those with negative expectations. Across all four studies, positive expectations encouraged developing outgroup attitudes consistent with interaction quality. © 2014 by the Society for Personality and Social Psychology, Inc.

  7. Evaluating the immediate postverbal position as a focus position in Zulu

    NARCIS (Netherlands)

    Buell, L.; Matondo, M.; McLaughlin, F.; Potsdam, E.

    2009-01-01

    It has been claimed that in Bantu languages a focused element must occur in the IAV (Immediately After the Verb) linear position, which in turn has been argued by some to constitute a syntactic focus position below IP. This paper examines the extent to which the IAV linear position is obligatory for

  8. Experimental study of effect of magnetic field on anode temperature distribution in an ATON-type Hall thruster

    Science.gov (United States)

    Liu, Jinwen; Li, Hong; Mao, Wei; Ding, Yongjie; Wei, Liqiu; Li, Jianzhi; Yu, Daren; Wang, Xiaogang

    2018-05-01

    The energy deposition caused by the absorption of electrons by the anode is an important cause of power loss in a Hall thruster. The resulting anode heating is dangerous, as it can potentially reduce the thruster lifetime. In this study, by considering the ring shape of the anode of an ATON-type Hall thruster, the effects of the magnetic field strength and gradient on the anode ring temperature distribution are studied via experimental measurement. The results show that the temperature distribution is not affected by changes in the magnetic field strength and that the position of the peak temperature is essentially unchanged; however, the overall temperature does not change monotonically with the increase of the magnetic field strength and is positively correlated with the change in the discharge current. Moreover, as the magnetic field gradient increases, the position of the peak temperature gradually moves toward the channel exit and the temperature tends to decrease as a whole, regardless of the discharge current magnitude; in any case, the position of the peak temperature corresponds exactly to the intersection of the magnetic field cusp with the anode ring. Further theoretical analysis shows that the electrons, coming from the ionization region, travel along two characteristic paths to reach the anode under the guidance of the cusped magnetic field configuration. The change of the magnetic field strength or gradient changes the transfer of momentum and energy of the electrons in these two paths, which is the main reason for the changes in the temperature and distribution. This study is instructive for matching the design of the ring-shaped anode and the cusp magnetic field of an ATON-type Hall thruster.

  9. [Positioning diagnosis of benign positional paroxysmal vertigo by VNG].

    Science.gov (United States)

    Wang, Na; Chen, Taisheng; Lin, Peng; Song, Wei; Dong, Hong

    2009-07-01

    To analyze the value of positioning diagnosis of VNG (Videonystagmograph) in patients with benign paroxysmal positional vertigo (BPPV). One hundred and twenty-six patients with BPPV were enrolled in this retrospective study. Their positional nystagmus recorded by VNG in Dix-Hallpike and roll tests were analyzed to summarize the characteristics of nystagmus on nystagmography of various BPPV. Of 126 patients with BPPV diagnosed in our center, the posterior semicircular canals (PSC) were involved in 98 patients (77.8%), whereas the horizontal semicircular canal (HSC) and anterior semicircular canal (ASC) were involved in 17 (13.5%) and 5 (3.9%), respectively. Six patients (4.8%) confirmed combined-BPPV had HSC-BPPV and ipsilateral PSC-BPPV. Twenty-eight patients with PSC-BPPV had reversal phase on nystagmography. The nystagmus of patients with P/ASC-canalithiasis showed upward/downward on the vertical phase of nystagmography and orientated the opposite side on horizontal phase in the head hanging position, and the nystagmus reversed when returned to sit. Nystagmus on horizontal phase could be provoked when the head turned to both sides of the roll tests in patients with HSC-BPPV. If the nystagmus and the head-turning shared the same direction, then HSC-canalithiasis was confirmed, and the direction of the head-turning which provoked the stronger nystagmus indicates the lesion side. If the nystagmus and the head-turning had the opposite direction, then HSC-cupulolithiasis was confirmed, and the direction of the head-turning which provoked the weaker nystagmus indicates the lesion side. Positional nystagmus can be recorded objectively using VNG, According to which positioning the semicircular canal involved would be easier and more accurate. The recording conserved also could be helpful for clinical diagnosis and repositioning of BPPV.

  10. Position display device

    International Nuclear Information System (INIS)

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  11. Particle and power balances of hot-filament discharge plasmas in a multi-dipole device in the presence of a positively biased electrode

    International Nuclear Information System (INIS)

    Cho, M.H.; Hershkowitz, N.; Intrator, T.

    1989-01-01

    The plasma potential is typically assumed to float above an anode potential by a few times of an electron temperature (T /e). The difference between the plasma potential and the anode potential can be estimated by considering the particle production and loss. However, it has been reported experimentally that the plasma potential of a steady state plasma can be more negative than the anode potential with a potential dip (-- T /e) in front of the anode. This paper describes particle and power balances to estimate the bulk plasma potential of a hot-filament discharge plasma produced in a multi-dipole plasma device. The bulk plasma potential dependence on positive DC bias applied to an anode is analyzed, and the predicted characteristics of the plasma potential dependence are compared to the experiment. A steady state potential dip in front of an anode is experimentally observed using emissive probes with the zero emission inflection point method, and the conditions for the potential dip formation are derived

  12. Diagnostic Setup for Characterization of Near-Anode Processes in Hall Thrusters

    International Nuclear Information System (INIS)

    Dorf, L.; Raitses, Y.; Fisch, N.J.

    2003-01-01

    A diagnostic setup for characterization of near-anode processes in Hall-current plasma thrusters consisting of biased and emissive electrostatic probes, high-precision positioning system and low-noise electronic circuitry was developed and tested. Experimental results show that radial probe insertion does not cause perturbations to the discharge and therefore can be used for accurate near-anode measurements

  13. Pretty Easy Pervasive Positioning

    DEFF Research Database (Denmark)

    Hansen, Rene; Wind, Rico; Jensen, Christian Søndergaard

    2009-01-01

    With the increasing availability of positioning based on GPS, Wi-Fi, and cellular technologies and the proliferation of mobile devices with GPS, Wi-Fi and cellular connectivity, ubiquitous positioning is becoming a reality. While offerings by companies such as Google, Skyhook, and Spotigo render...... positioning possible in outdoor settings, including urban environments with limited GPS coverage, they remain unable to offer accurate indoor positioning. We will demonstrate a software infrastructure that makes it easy for anybody to build support for accurate Wi-Fi based positioning in buildings. All...... that is needed is a building with Wi-Fi coverage, access to the building, a floor plan of the building, and a Wi-Fi enabled device. Specifically, we will explain the software infrastructure and the steps that must be completed to obtain support for positioning. And we will demonstrate the positioning obtained...

  14. Initial development and structure of biofilms on microbial fuel cell anodes

    Directory of Open Access Journals (Sweden)

    Keller Jürg

    2010-04-01

    Full Text Available Abstract Background Microbial fuel cells (MFCs rely on electrochemically active bacteria to capture the chemical energy contained in organics and convert it to electrical energy. Bacteria develop biofilms on the MFC electrodes, allowing considerable conversion capacity and opportunities for extracellular electron transfer (EET. The present knowledge on EET is centred around two Gram-negative models, i.e. Shewanella and Geobacter species, as it is believed that Gram-positives cannot perform EET by themselves as the Gram-negatives can. To understand how bacteria form biofilms within MFCs and how their development, structure and viability affects electron transfer, we performed pure and co-culture experiments. Results Biofilm viability was maintained highest nearer the anode during closed circuit operation (current flowing, in contrast to when the anode was in open circuit (soluble electron acceptor where viability was highest on top of the biofilm, furthest from the anode. Closed circuit anode Pseudomonas aeruginosa biofilms were considerably thinner compared to the open circuit anode (30 ± 3 μm and 42 ± 3 μm respectively, which is likely due to the higher energetic gain of soluble electron acceptors used. The two Gram-positive bacteria used only provided a fraction of current produced by the Gram-negative organisms. Power output of co-cultures Gram-positive Enterococcus faecium and either Gram-negative organisms, increased by 30-70% relative to the single cultures. Over time the co-culture biofilms segregated, in particular, Pseudomonas aeruginosa creating towers piercing through a thin, uniform layer of Enterococcus faecium. P. aeruginosa and E. faecium together generated a current of 1.8 ± 0.4 mA while alone they produced 0.9 ± 0.01 and 0.2 ± 0.05 mA respectively. Conclusion We postulate that this segregation may be an essential difference in strategy for electron transfer and substrate capture between the Gram-negative and the Gram-positive

  15. Study on energy and position resolution of MWPC for the Beijing e/π test beam

    International Nuclear Information System (INIS)

    Shen Ji; Chen Ziyu; Ye Yunxiu; Cui Xiangzong; Li Jiacai

    2006-01-01

    This paper describes the research on the energy and position resolution of the MWPC used in the e/π Test Beam on BEPC (Beijing Electron Positron Collider), which localizes the particles of e/π by the readout method of gravity center of the induced charges on the cathode strips. The spatial resolution of about 0.24 mm and energy resolution of 17% for 5.9 keV γ photons are attained at the 3700 V anode voltage. For the 1.1 GeV electrons, the spatial resolution of 0.3 mm is obtained. The contributions of various factors to energy resolution are analysed. It is found that energy resolution is changed with the anode voltage and there exists a least energy resolution. The reasons for these are discussed. (authors)

  16. Development of Precise Point Positioning Method Using Global Positioning System Measurements

    Directory of Open Access Journals (Sweden)

    Byung-Kyu Choi

    2011-09-01

    Full Text Available Precise point positioning (PPP is increasingly used in several parts such as monitoring of crustal movement and maintaining an international terrestrial reference frame using global positioning system (GPS measurements. An accuracy of PPP data processing has been increased due to the use of the more precise satellite orbit/clock products. In this study we developed PPP algorithm that utilizes data collected by a GPS receiver. The measurement error modelling including the tropospheric error and the tidal model in data processing was considered to improve the positioning accuracy. The extended Kalman filter has been also employed to estimate the state parameters such as positioning information and float ambiguities. For the verification, we compared our results to other of International GNSS Service analysis center. As a result, the mean errors of the estimated position on the East-West, North-South and Up-Down direction for the five days were 0.9 cm, 0.32 cm, and 1.14 cm in 95% confidence level.

  17. The method to evaluate the position error in graphic positioning technology

    Institute of Scientific and Technical Information of China (English)

    Huiqing Lu(卢慧卿); Baoguang Wang(王宝光); Lishuang Liu(刘力双); Yabiao Li(李亚标)

    2004-01-01

    In the measurement of automobile body-in-white, it has been widely studied to position the two dimensional(2D)visual sensors with high precision. In this paper a graphic positioning method is proposed,a hollow tetrahedron is used for a positioning target to replace all the edges of a standard automobile body.A 2D visual sensor can be positioned through adjusting two triangles to be superposed on a screen of the computer, so it is very important to evaluate the superposition precision of the two triangles. Several methods are discussed and the least square method is adopted at last, it makes the adjustment more easy and intuitive with high precision.

  18. From Positive Reinforcement to Positive Behaviors: An Everyday Guide for the Practitioner

    Science.gov (United States)

    Sigler, Ellen A.; Aamidor, Shirley

    2005-01-01

    There are various opinions concerning the value of positive reinforcement when discussing modifying behaviors of young children. In some cases, individuals considered positive reinforcement difficult to implement and, in extreme cases, even felt it to be detrimental. Educators often use praise interchangeably with positive reinforcement when…

  19. Benign positional vertigo - aftercare

    Science.gov (United States)

    Vertigo - positional - aftercare; Benign paroxysmal positional vertigo - aftercare; BPPV - aftercare; Dizziness - positional vertigo ... Your health care provider may have treated your vertigo with the Epley maneuver . These are head movements ...

  20. Position encoder

    International Nuclear Information System (INIS)

    Goursky, Vsevolod

    1975-01-01

    A circuitry for deriving the quotient of signal delivered by position-sensitive detectors is described. Digital output is obtained in the form of 10- to 12-bit words. Impact position may be determined with 0.25% accuracy when the dynamic range of the energy signal is less 1:10, and 0.5% accuracy when the dynamic range is 1:20. The division requires an average time of 5μs for 10-bit words

  1. 1-D position sensitive single carrier semiconductor detectors

    International Nuclear Information System (INIS)

    Zhong He; Knoll, G.F.; Wehe, D.K.; Rojeski, R.; Mastrangelo, C.H.; Hammig, M.; Barrett, C.; Uritani, A.

    1996-01-01

    A single polarity charge sensing method has been studied using coplanar electrodes on 5 mm cubes of CdZnTe γ-ray detectors. This method can ameliorate the hole trapping problem of room-temperature semiconductor detectors. Our experimental results confirm that the energy resolution is dramatically improved compared with that obtained using the conventional readout method, but is still about an order of magnitude worse than the theoretical limit. A method to obtain the γ-ray interaction depth between the cathode and the anode is presented here. This technique could be used to correct for the electron trapping as a function of distance from the coplanar electrodes. Experimental results showed that a position resolution of about 0.9 mm FWHM at 122 keV can be obtained. These results will be of interest in the design of higher performance room-temperature semiconductor γ-ray detectors. (orig.)

  2. Clinical Positioning Space

    DEFF Research Database (Denmark)

    Williams, Lars Peter Hedegaard; Christensen, Mette Krogh; Rytter, Carsten

    2014-01-01

    In this article, we present a case study of residents’ clinical experiences and communication in outpatient oncology consultations. We apply positioning theory, a dynamic alternative to role theory, to investigate how oncology residents and patients situate themselves as persons with rights...... and duties. Drawing from seven qualitative interviews and six days of observation, we investigate the residents’ social positioning and their conversations with patients or supervisors. Our focus is on how (a) relational shifts in authority depend on each situation and its participants; (b) storylines...... establish acts and positions and narratively frame what participants can expect from a medical consultation viewed as a social episode; and (c) the positioning of rights and duties can lead to misunderstandings and frustrations. We conclude that residents and patients locate themselves in outpatient...

  3. Position encoder

    International Nuclear Information System (INIS)

    Goursky, V.

    1975-05-01

    This paper describes circuitry for deriving the quotient of signals delivered by position-sensitive detectors. Digital output is obtained in the form of 10 to 12 bit words. Impact position may be determined with 0.25% accuracy when the dynamic range of the energy signal is less than 1:10, and 0.5% accuracy when the dynamic range is 1:20. The division requires an average time of 5μs for 10-bit words [fr

  4. Positional games

    CERN Document Server

    Hefetz, Dan; Stojaković, Miloš; Szabó, Tibor

    2014-01-01

    This text serves as a thorough introduction to the rapidly developing field of positional games. This area constitutes an important branch of combinatorics, whose aim it is to systematically develop an extensive mathematical basis for a variety of two-player perfect information games. These range from such popular games as Tic-Tac-Toe and Hex to purely abstract games played on graphs and hypergraphs. The subject of positional games is strongly related to several other branches of combinatorics such as Ramsey theory, extremal graph and set theory, and the probabilistic method. These notes cover a variety of topics in positional games, including both classical results and recent important developments. They are presented in an accessible way and are accompanied by exercises of varying difficulty, helping the reader to better understand the theory. The text will benefit both researchers and graduate students in combinatorics and adjacent fields.

  5. Accentuate the Positive: Positive Sentiments and Status in Task Groups

    Science.gov (United States)

    Bianchi, Alison J.; Lancianese, Donna A.

    2007-01-01

    We explore the capacity of positive sentiments, those enduring affective states one achieves when one likes another, to impact status structures. Do positive sentiments combine with existing aspects of interaction to create status hierarchies and potentially change the social order, or do they moderate the effects of extant structure by dampening…

  6. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  7. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  8. X-ray beam-position feedback system with easy-to-use beam-position monitor.

    Science.gov (United States)

    Park, Jae Yeon; Kim, Yesul; Lee, Sangsul; Lim, Jun

    2018-05-01

    X-ray beam-position stability is indispensable in cutting-edge experiments using synchrotron radiation. Here, for the first time, a beam-position feedback system is presented that utilizes an easy-to-use X-ray beam-position monitor incorporating a diamond-fluorescence screen. The acceptable range of the monitor is above 500 µm and the feedback system maintains the beam position within 3 µm. In addition to being inexpensive, the system has two key advantages: it works without a scale factor for position calibration, and it has no dependence on X-ray energy, X-ray intensity, beam size or beam shape.

  9. Electrochemical reduction of oxygen catalyzed by a wide range of bacteria including Gram-positive

    Energy Technology Data Exchange (ETDEWEB)

    Cournet, Amandine [Universite de Toulouse, UPS, LU49, Adhesion Bacterienne et Formation de Biofilms, 35 chemin des Maraichers, 31 062 Toulouse cedex 09 (France); Laboratoire de Genie Chimique CNRS, Universite de Toulouse, 4 allee Emile Monso, BP 84234, 31432 Toulouse cedex 04 (France); Delia, Marie-Line; Bergel, Alain [Laboratoire de Genie Chimique CNRS, Universite de Toulouse, 4 allee Emile Monso, BP 84234, 31432 Toulouse cedex 04 (France); Roques, Christine; Berge, Mathieu [Universite de Toulouse, UPS, LU49, Adhesion Bacterienne et Formation de Biofilms, 35 chemin des Maraichers, 31 062 Toulouse cedex 09 (France)

    2010-04-15

    Most bacteria known to be electrochemically active have been harvested in the anodic compartments of microbial fuel cells (MFCs) and are able to use electrodes as electron acceptors. The reverse phenomenon, i.e. using solid electrodes as electron donors, is not so widely studied. To our knowledge, most of the electrochemically active bacteria are Gram-negative. The present study implements a transitory electrochemical technique (cyclic voltammetry) to study the microbial catalysis of the electrochemical reduction of oxygen. It is demonstrated that a wide range of aerobic and facultative anaerobic bacteria are able to catalyze oxygen reduction. Among these electroactive bacteria, several were Gram-positive. The transfer of electrons was direct since no activity was obtained with the filtrate. These findings, showing a widespread property among bacteria including Gram-positive ones, open new and interesting routes in the field of electroactive bacteria research. (author)

  10. Study of position resolution for cathode readout MWPC with measurement of induced charge distribution

    International Nuclear Information System (INIS)

    Chiba, J.; Iwasaki, H.; Kageyama, T.; Kuribayashi, S.; Nakamura, K.; Sumiyoshi, T.; Takeda, T.

    1983-01-01

    A readout technqiue of multiwire proportional chambers by measurement of charges induced on cathode strips, orthogonal to anode wires, requires an algorithm to relate the measured charge distribution to the avalanche position. With given chamber parameters and under the influence of noise, resolution limits depend on the chosen algorithm. We have studied the position resolution obtained by the centroid method and by the charge-ratio method, both using three consecutive cathode strips. While the centroid method uses a single number, the center of gravity of the measured charges, the charge-ratio method uses the ratios of the charges Qsub(i-1)/Qsub(i) and Qsub(i+1)/Qsub(i) where Qsub(i) is the largest. To obtain a given resolution, the charge-ratio method generally allows wider cathode strips and therefore a smaller number of readout channels than the centroid method. (orig.)

  11. Position-sensitive proportional counters using resistance-capacitance position encoding

    International Nuclear Information System (INIS)

    Kopp, M.K.; Borkowski, C.J.

    1975-12-01

    A new method was developed for encoding the position of individual photons, neutrons, or charged particles in proportional counters by using the distributed RC line characteristics of these counters. The signal processing is described and guidelines for the design and operation of these position sensitive proportional counters (PSPCs) are given. Using these guidelines, several prototypic PSPCs were constructed to improve the spatial resolution and shorten the signal processing time; for example, the intrinsic spatial uncertainty was reduced to 28 μ fwhm for alpha particles and 100 μ fwhm for low-energy x rays (2 to 6 keV). Also, the signal processing time was reduced to 0.6 μsec without seriously degrading the spatial resolution. These results have opened new fields of application of the RC position encoding method in imaging distributions of photons, charged particles, or neutrons in nuclear medicine, physics, and radiography

  12. Cognitive Engagement Mediates the Relationship between Positive Life Events and Positive Emotionality

    Directory of Open Access Journals (Sweden)

    Alexander Strobel

    2017-10-01

    Full Text Available Need for Cognition (NFC is conceptualized as an individuals’ tendency to engage in and enjoy effortful cognitive activity and, thus, captures one’s cognitive engagement. It plays a well-established role in information processing in experimental or academic contexts. However, so far comparably little is known about its consequences for other than purely cognitive or academic outcomes. Indeed, NFC is positively associated with personality traits pertaining to Positive Emotionality (PE and negatively to traits related to Negative Emotionality (NE. Moreover, evidence suggests NFC to be related to an active, problem-focused coping style. We therefore hypothesized NFC to mediate between life events and individual differences in PE and NE. In a sample of N = 202 volunteers from the general population, we observed that the number of past positive and negative life events had direct effects on PE, and NE, respectively, and that for positive life events, a mediating effect on PE via NFC was observed, with a higher number of past positive life events being related to higher NFC that in turn was related to increased PE. Thus, the present results lend support to the notion of NFC as an important factor supporting personal well-being by way of its mediating role between the number of past positive life events and positive affect.

  13. Positive criminology in practice.

    Science.gov (United States)

    Ronel, Natti; Segev, Dana

    2014-11-01

    The discourse regarding offender rehabilitation has been criticized by various scholars who have claimed that reducing negative causes and managing risk will not automatically prompt positive human development and elements that are associated with desistance. Positive criminology is an innovative concept that challenges the common preoccupation with negative elements, by placing emphasis on human encounters and forces of inclusion that are experienced positively by target individuals and that can promote crime desistance. However, as the concept is relatively new, there are still no guiding principles for the practice of positive criminology that could direct research and the criminal justice system. This article attempts to fill that gap by providing principles that could be practiced by criminal justice personnel and examples of different interventions that reflect positive criminology. The article also provides ideological explanations for adopting the concept of positive criminology in practice. © The Author(s) 2013.

  14. Positive emotion, appraisal, and the role of appraisal overlap in positive emotion co-occurrence.

    Science.gov (United States)

    Tong, Eddie M W; Jia, Lile

    2017-02-01

    Appraisal research has traditionally focused on negative emotions but has not addressed issues concerning the relationships between several positive emotions and appraisals in daily life and the extent to which co-occurrence of positive emotions can be explained by overlap in appraisals. Driven by a priori hypotheses on appraisal-emotion relationships, this study investigated 12 positive emotions and 13 appraisal dimensions using Ecological Momentary Assessment. The results provide strong evidence that positive emotions and appraisals correlate significantly in daily life. Importantly, we found that the positive emotions' overlap on theoretically relevant, as compared to irrelevant, appraisals was stronger and more predictive of their co-occurrence. Furthermore, appraisal overlap on theoretically relevant appraisals predicted the co-occurrence of positive emotions even when the appraisal of pleasantness was excluded, indicating that positive emotions do not co-occur just by virtue of their shared valence. Our findings affirmed and refined the appraisal profiles of positive emotions and underscore the importance of appraisals in accounting for the commonality and differences among positive emotions. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  16. Ralicon anodes for image photon counting fabricated by electron beam lithography

    International Nuclear Information System (INIS)

    Burton, W.M.

    1982-01-01

    The Anger wedge and strip anode event location system developed for microchannel plate image photon detectors at the Space Sciences Laboratory of the University of California, Berkeley, has been extended in the present work by the use of electron beam lithography (EBL). This method of fabrication can be used to produce optical patterns for the subsequent manufacture of anodes by conventional photo-etching methods and has also enabled anodes to be produced directly by EBL microfabrication techniques. Computer-aided design methods have been used to develop several types of RALICON (Readout Anodes of Lithographic Construction) for use in photon counting microchannel plate imaging detectors. These anodes are suitable for linear, two dimensional or radial position measurements and they incorporate novel design features made possible by the EBL fabrication technique which significantly extend their application relative to published wedge-strip anode designs. (author)

  17. Discrimination of the wall effect in a thin counter with micro-gap structure for neutron position sensing

    Energy Technology Data Exchange (ETDEWEB)

    Sakae, Takeji; Manabe, Tohru; Kitamura, Yasunori; Nohtomi, Akihiro [Kyushu Univ., Fukuoka (Japan); Sakamoto, Sigeyasu

    1996-07-01

    Simulation by the Monte Carlo method is applied to estimate the wall effect in a thermal neutron counter having a new function for discriminating the effect. The counter is designed to have paralleled electrodes with micro-gap structure. A resistive anode is used for position sensing on the center of a set of the three electrode. The structure can be made by simple arrangement of anode and cathode wires on an insulator plane. The calculation shows discrimination of the wall effect can be achieved by coincident counting of two or three elements included in the counter. By using the coincident counting, the thickness of the neutron counter can be made into 1 mm with the information of the total energy created in the neutron detection. (author)

  18. Position coincidence optical identifications using Texas interferometer radio positions

    International Nuclear Information System (INIS)

    Bozyan, E.P.

    1979-01-01

    1048 radio source positions measured with the Texas Interferometer were searched for optical identifications on glass copies of the Palomar Sky Survey E and O plates, resulting in 242 identifications and 806 blank fields. Finding charts are presented for 124 of the 125 new identifications not previously reported in the literature, and for 73 blank fields containing nearby optical objects which may be real identifications. This brings the cumulative number of Texas radio positions searched to 2015, producing 864 optical identifications and 1151 blank fields

  19. Longitudinal Relations among Positivity, Perceived Positive School Climate, and Prosocial Behavior in Colombian Adolescents

    Science.gov (United States)

    Luengo Kanacri, Bernadette P.; Eisenberg, Nancy; Thartori, Eriona; Pastorelli, Concetta; Uribe Tirado, Liliana M.; Gerbino, Maria; Caprara, Gian V.

    2017-01-01

    Bidirectional relations among adolescents' positivity, perceived positive school climate, and prosocial behavior were examined in Colombian youth. Also, the role of a positive school climate in mediating the relation of positivity to prosocial behaviors was tested. Adolescents (N = 151; M[subscript age] of child in Wave 1 = 12.68, SD = 1.06; 58.9%…

  20. Self-calibrating solar position sensor

    Science.gov (United States)

    Maxey, Lonnie Curt

    2018-01-30

    A sun positioning sensor and method of accurately tracking the sun are disclosed. The sensor includes a position sensing diode and a disk having a body defining an aperture for accepting solar light. An extension tube having a body that defines a duct spaces the position sensing diode from the disk such that the solar light enters the aperture in the disk, travels through the duct in the extension tube and strikes the position sensing diode. The extension tube has a known length that is fixed. Voltage signals indicative of the location and intensity of the sun are generated by the position sensing diode. If it is determined that the intensity values are unreliable, then historical position values are used from a table. If the intensity values are deemed reliable, then actual position values are used from the position sensing diode.

  1. Thinking back about a positive event: The impact of processing style on positive affect

    Directory of Open Access Journals (Sweden)

    Sabine eNelis

    2015-03-01

    Full Text Available The manner in which individuals recall an autobiographical positive life event has affective consequences. Two studies addressed the processing styles during positive memory recall in a non-clinical sample. Participants retrieved a positive memory which was self-generated (Study 1, n = 70 or experimenter-chosen (i.e., academic achievement, Study 2, n = 159, followed by the induction of one of three processing styles (between-subjects: In Study 1, a ‘concrete/imagery’ vs. ‘abstract/verbal’ processing style was compared. In Study 2, a ‘concrete/imagery’, ‘abstract/verbal’, and ‘comparative/verbal’ processing style were compared. The processing of a personal memory in a concrete/imagery-based way led to a larger increase in positive affect compared to abstract/verbal processing in Study 1, as well as compared to comparative/verbal thinking in Study 2. Results of Study 2 further suggest that it is making unfavourable verbal comparisons that may hinder affective benefits to positive memories (rather then general abstract/verbal processing per se. The comparative/verbal thinking style failed to lead to improvements in positive affect, and with increasing levels of depressive symptoms it had a more negative impact on change in positive affect. We found no evidence that participant’s tendency to have dampening thoughts in response to positive affect in daily life contributed to the affective impact of positive memory recall. The results support the potential for current trainings in boosting positive memories and mental imagery, and underline the search for parameters that determine at times deleterious outcomes of abstract/verbal memory processing in the face of positive information.

  2. Modern management positions

    Directory of Open Access Journals (Sweden)

    Jovanović Petar M.

    2015-01-01

    Full Text Available In this paper we analyze contemporary managerial positions such as program manager, project portfolio manager, crisis manager and others. The idea is to promote managerial positions in Serbia, which is quite unjustifiably undervalued, primarily because of the lack of knowledge in the field of management and other issues related to management education.

  3. Secure positioning in wireless networks

    DEFF Research Database (Denmark)

    Capkun, Srdjan; Hubaux, Jean-Pierre

    2006-01-01

    So far, the problem of positioning in wireless networks has been studied mainly in a non-adversarial settings. In this work, we analyze the resistance of positioning techniques to position and distance spoofing attacks. We propose a mechanism for secure positioning of wireless devices, that we call...... Verifiable Multilateration. We then show how this mechanism can be used to secure positioning in sensor networks. We analyze our system through simulations....

  4. Navicular bone position determined by positional MRI

    DEFF Research Database (Denmark)

    Hansen, Philip; Johannsen, Finn E; Hangaard, Stine

    2016-01-01

    -scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). RESULTS...

  5. Positioning and applications

    Directory of Open Access Journals (Sweden)

    Rogowski Jerzy B.

    2015-12-01

    Full Text Available The paper presents national report of Poland for IAG on positioning and applications. The selected research presented was carried out at leading Polish research institutions and concern precise multi-GNSS satellite positioning - relative and absolute - and also GNSS-based ionosphere and troposphere modelling and studies. The research resulted in noticeable advancements in these subjects confirmed by the development of new algorithms and methods. New and improved methods of precise GNSS positioning were developed, and also GNSS metrology was studied. New advanced troposphere models were presented and tested. In particular, these models allowed testing IPW variability on regional and global scales. Also, new regional ionosphere monitoring web-based services were developed and launched.

  6. Exposing Position Uncertainty in Middleware

    DEFF Research Database (Denmark)

    Langdal, Jakob; Kjærgaard, Mikkel Baun; Toftkjær, Thomas

    2010-01-01

    Traditionally, the goal for positioning middleware is to provide developers with seamless position transparency, i.e., providing a connection between the application domain and the positioning sensors while hiding the complexity of the positioning technologies in use. A key part of the hidden com...

  7. Thruster allocation for dynamical positioning

    NARCIS (Netherlands)

    Poppe, K.; van den Berg, J.B.; Blank, E.; Archer, C.; Redeker, M.; Kutter, M.; Hemker, P.

    2010-01-01

    Positioning a vessel at a fixed position in deep water is of great importance when working offshore. In recent years a Dynamical Positioning (DP) system was developed at Marin [2]. After the measurement of the current position and external forces (like waves, wind etc.), each thruster of the vessel

  8. Tungsten anode tubes with K-edge filters for mammography

    Energy Technology Data Exchange (ETDEWEB)

    Beaman, S.; Lillicrap, S.C. (Wessex Regional Medical Physics Service, Bath (UK)); Price, J.L. (Jarvis Screening Centre, Guildford (UK))

    1983-10-01

    Optimum X-ray energies for mammography have previously been calculated using the maximum signal to noise ratio (SNR) per unit dose to the breast, or the minimum exposure for constant SNR. Filters having absorption edges at appropriate energy positions have been used to modify the shape of tungsten anode spectra towards the calculated optimum. The suitability of such spectra for practical use has been assessed by comparing the film image quality and the incident breast dose obtained using a K-edge filtered tungsten anode tube with that obtained using a molybdenum anode. Image quality has been assessed by using a 'random' phantom and by comparing mammograms where one breast was radiographed using a filtered tungsten anode tube and the other using a standard molybdenum anode unit. Relative breast doses were estimated from both ionisation chamber measurements with a phantom and thermoluminescent dosimetry measurements on the breast. Film image quality assessment indicated that the filtered tungsten anode tube gave results not significantly different from those obtained with a molybdenum anode tube for a tissue thickness of about 4 cm and which were better for larger breast thicknesses. Doses could be reduced to between one-half and one-third with the filtered tungsten anode tube.

  9. Tungsten anode tubes with K-edge filters for mammography

    International Nuclear Information System (INIS)

    Beaman, S.; Lillicrap, S.C.; Price, J.L.

    1983-01-01

    Optimum X-ray energies for mammography have previously been calculated using the maximum signal to noise ratio (SNR) per unit dose to the breast, or the minimum exposure for constant SNR. Filters having absorption edges at appropriate energy positions have been used to modify the shape of tungsten anode spectra towards the calculated optimum. The suitability of such spectra for practical use has been assessed by comparing the film image quality and the incident breast dose obtained using a K-edge filtered tungsten anode tube with that obtained using a molybdenum anode. Image quality has been assessed by using a 'random' phantom and by comparing mammograms where one breast was radiographed using a filtered tungsten anode tube and the other using a standard molybdenum anode unit. Relative breast doses were estimated from both ionisation chamber measurements with a phantom and thermoluminescent dosimetry measurements on the breast. Film image quality assessment indicated that the filtered tungsten anode tube gave results not significantly different from those obtained with a molybdenum anode tube for a tissue thickness of abut 4 cm and which were better for larger breast thicknesses. Doses could be reduced to between one-half and one-third with the filtered tungsten anode tube. (U.K.)

  10. Anterior semicircular canal benign paroxysmal positional vertigo and positional downbeating nystagmus.

    Science.gov (United States)

    Lopez-Escamez, Jose A; Molina, Maria I; Gamiz, Maria J

    2006-01-01

    The aim of this study was to describe the clinical features and video-oculographic findings in patients with anterior semicircular canal benign paroxysmal positional vertigo (BPPV). This is a prospective case series. The study was set at an outpatient clinic in a general hospital. Fourteen individuals with symptoms of BPPV and positional downbeating nystagmus (pDBN) were included in the study. The diagnosis was based on a history of brief episodes of vertigo and the presence of pDBN confirmed in the video-oculographic examination during Dix-Hallpike test (DH) or head-hanging maneuver. Patients were treated by particle repositioning maneuver and the effectiveness was evaluated at 7, 30, and 180 days posttreatment. The treatment was repeated up to 4 times if pDBN was persistent. The main outcome measure is the number of patients without pDBN at 30 and 180 days. Video-oculography showed a predominant pDBN in response to DH. Of the 14 patients, 7 had arterial hypertension, and 5 of 14 cases presented abnormalities on the caloric test. Horizontal spontaneous nystagmus was found in 3 of 14 individuals. Positional nystagmus at different positional test was observed in 5 of 14 individuals, suggesting the involvement of several canals. Of the 14 patients, 10 (71%) did not present vertigo, and the positional tests were negative at 30 days. However, 3 cases presented a positive DH with persistence of BPPV episodes and pDBN at 30 days, and another developed a contralateral posterior canal affectation. One of the patients maintained a persistent pDBN at 180 days despite the repeated maneuvers. Video-oculography demonstrates that anterior canal BPPV is characterized by a predominant downbeating nystagmus in response to DH. These individuals may show alterations in the vestibular caloric, and they can have multicanal affectation.

  11. Connecting Positive Psychology and Organizational Behavior Management: Achievement Motivation and the Power of Positive Reinforcement

    Science.gov (United States)

    Wiegand, Douglas M.; Geller, E. Scott

    2005-01-01

    Positive psychology is becoming established as a reputable sub-discipline in psychology despite having neglected the role of positive reinforcement in enhancing quality of life. The authors discuss the relevance of positive reinforcement for positive psychology, with implications for broadening the content of organizational behavior management.…

  12. Review of Positional Nystagmus

    Directory of Open Access Journals (Sweden)

    José Ignacio BENITO-OREJAS

    2018-01-01

    Full Text Available Introduction and objective: Any change of position of the head (dynamic or static can trigger a nystagmus or increase the spontaneous. This nystagmus we call it positional. We intend to review in this chapter its definition, clinical features, etiology and the way of exploring it. Method: narrative review. Results: Positional vertigo is the most frequent vestibular disorder, and most of the times of peripheral cause. Characteristics of nystagmus or its association with other neurological symptoms are sufficient grounds to request a magnetic resonance, which will provide additional information on very few occasions. Discussion: The study of the positional nystagmus as a procedure to rule out central pathology has lost much of its relevance. Signs that Nylén defined mixed findings peripheral and central, making complex classification. Conclusion: Regardless of how to bring the patient change position (very slow or fast, if it appears an atypical nystagmus should rule out a central origin.

  13. Cam Mover Alignment System positioning with the Wire Positioning with the Wire Position Sensor Feedback for CLIC

    CERN Document Server

    AUTHOR|(CDS)2077936; Mainaud Durand, Helene; Kostka, Z.S.

    2016-01-01

    Compact Linear Collider (CLIC) is a study of an electron-positron collider with nominal energy of 3 TeV and luminosity of 2 ∙ 1034 cm-2s-1. The luminosity goal leads to stringent alignment requirements for single quadrupole magnets. Vertical and lateral offset deviations with regards to a given orbit reference in both ends of a quadrupole shall be below 1 μm and quadrupole roll deviation shall be below 100 μrad. Translation in the direction of particle beam is not controlled but mechanically locked. A parallel kinematic platform based on cam movers was chosen as system for detailed studies. Earlier studies have shown that cam movers can reach the CLIC requirements through an iterative process. The paper presents new modular off-the-shelf control electronics and software including three optional positioning algorithms based on iterations as well as a more advanced algorithm which can reach target position in one movement. The advanced algorithm reads wire position sensors (WPS), calculates quadrupole orien...

  14. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives.

    Science.gov (United States)

    Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens

    2013-04-07

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.

  15. Scalability Optimization of Seamless Positioning Service

    Directory of Open Access Journals (Sweden)

    Juraj Machaj

    2016-01-01

    Full Text Available Recently positioning services are getting more attention not only within research community but also from service providers. From the service providers point of view positioning service that will be able to work seamlessly in all environments, for example, indoor, dense urban, and rural, has a huge potential to open new markets. However, such system does not only need to provide accurate position estimates but have to be scalable and resistant to fake positioning requests. In the previous works we have proposed a modular system, which is able to provide seamless positioning in various environments. The system automatically selects optimal positioning module based on available radio signals. The system currently consists of three positioning modules—GPS, GSM based positioning, and Wi-Fi based positioning. In this paper we will propose algorithm which will reduce time needed for position estimation and thus allow higher scalability of the modular system and thus allow providing positioning services to higher amount of users. Such improvement is extremely important, for real world application where large number of users will require position estimates, since positioning error is affected by response time of the positioning server.

  16. Phantom position dependence

    International Nuclear Information System (INIS)

    Thorson, M.R.; Endres, G.W.R.

    1981-01-01

    Sensitivity of the Hanford dosimeter response to its position relative to the phantom and the neutron source has always been recognized. A thorough investigation was performed to quantify dosimeter response according to: (a) dosimeter position on phantom, (b) dosimeter distance from phantom, and (c) angular relationship of dosimeter relative to neutron source and phantom. Results were obtained for neutron irradiation at several different energies

  17. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  18. Control rod position control device

    International Nuclear Information System (INIS)

    Ubukata, Shinji.

    1997-01-01

    The present invention provides a control rod position control device which stores data such as of position signals and driving control rod instruction before and after occurrence of abnormality in control for the control rod position for controlling reactor power and utilized the data effectively for investigating the cause of abnormality. Namely, a plurality of individual control devices have an operation mismatching detection circuit for outputting signals when difference is caused between a driving instruction given to the control rod position control device and the control rod driving means and signals from a detection means for detecting an actual moving amount. A general control device collectively controls the individual control devices. In addition, there is also disposed a position storing circuit for storing position signals at least before and after the occurrence of the control rod operation mismatching. With such procedures, the cause of the abnormality can be determined based on the position signals before and after the occurrence of control rod mismatching operation stored in the position storing circuit. Accordingly, the abnormality cause can be determined to conduct restoration in an early stage. (I.S.)

  19. Multiple-photon disambiguation on stripline-anode Micro-Channel Plates

    Energy Technology Data Exchange (ETDEWEB)

    Jocher, Glenn R., E-mail: glenn.jocher@ultralytics.com [Ultralytics LLC, Arlington, VA 22203 (United States); Wetstein, Matthew J., E-mail: mwetstein@uchicago.edu [Iowa State University, Department of Physics and Astronomy, 12 Physics Hall, Ames, IA 50011 (United States); Adams, Bernhard, E-mail: badams@incomusa.com [Incom, Inc., 294 Southbridge Road, Charlton, MA 01507 (United States); Nishimura, Kurtis, E-mail: kurtis.nishimura@ultralytics.com [Ultralytics LLC, Arlington, VA 22203 (United States); Usman, Shawn M., E-mail: shawn.usman@nga.mil [Research Directorate, National Geospatial-Intelligence Agency, 7500 GEOINT Dr., Springfield, VA 22150 (United States); Department of Geography and Geoinformation Science, George Mason University, Fairfax, VA 22030 (United States)

    2016-06-21

    Large-Area Picosecond Photo-Detectors (LAPPDs) show great potential for expanding the performance envelope of Micro-Channel Plates (MCPs) to areas of up to 20×20 cm and larger. Such scaling introduces new challenges, including how to meet the electronics readout burden of ever larger area MCPs. One solution is to replace the traditional grid anode used for readout with a microwave stripline anode, thus allowing the channel count to scale with MCP width rather than area. However, stripline anodes introduce new issues not commonly dealt with in grid-anodes, especially as their length increases. One of these issues is the near simultaneous arrival of multiple photons on the detector, creating possible confusion about how to reconstruct their arrival times and positions. We propose a maximum a posteriori solution to the problem and verify its performance in simulated scintillator and water-Cherenkov detectors.

  20. Nutrition and HIV-Positive Pregnancy

    OpenAIRE

    Montgomery, Kristen S.

    2003-01-01

    When an HIV-positive woman becomes pregnant, additional nutritional considerations are warranted. Compared to routine prenatal nutritional assessment and intervention, pregnant HIV-positive women have increased needs to promote a healthy outcome. This column contains information on HIV and pregnancy, nutrition and infection, and nutrition for HIV-positive pregnancy. This content can be integrated into childbirth education settings to improve care to women who are HIV-positive.

  1. Plasma position control device

    International Nuclear Information System (INIS)

    Takase, Haruhiko.

    1987-01-01

    Purpose: To conduct position control stably to various plasmas and reduce the burden on the control coil power source. Constitution: Among the proportional, integration and differentiation controls, a proportional-differentiation control section and an integration control section are connected in parallel. Then, a signal switching circuit is disposed to the control signal input section for the proportional-differentiation control section such that either a present position of plasmas or deviation between the present plasma position and an aimed value can be selected as a control signal depending on the control procedures or the state of the plasmas. For instance, if a rapid response is required for the control, the deviation between the present plasma position and the aimed value is selected as the input signal to conduct proportional, integration and differentiation controls. While on the other hand, if it is intended to reduce the burden on the control coil power source, it is adapted such that the control signal inputted to the proportional-differentiation control section itself can select the present plasma position. (Yoshihara, H.)

  2. Hollow-anode plasma source for molecular beam epitaxy of gallium nitride

    International Nuclear Information System (INIS)

    Anders, A.; Newman, N.; Rubin, M.; Dickinson, M.; Jones, E.; Phatak, P.; Gassmann, A.

    1996-01-01

    GaN films have been grown by molecular beam epitaxy (MBE) using a hollow-anode nitrogen plasma source. The source was developed to minimize defect formation as a result of contamination and ion damage. The hollow-anode discharge is a special form of glow discharge with very small anode area. A positive anode voltage drop of 30 endash 40 V and an increased anode sheath thickness leads to ignition of a relatively dense plasma in front of the anode hole. Driven by the pressure gradient, the open-quote open-quote anode close-quote close-quote plasma forms a bright plasma jet streaming with supersonic velocity towards the substrate. Films of GaN have been grown on (0001) SiC and (0001) Al 2 O 3 at 600 endash 800 degree C. The films were investigated by photoluminescence, cathodoluminescence, x-ray diffraction, Rutherford backscattering, and particle-induced x-ray emission. The film with the highest structural quality had a rocking curve width of 5 arcmin, the lowest reported value for MBE growth to date. copyright 1996 American Institute of Physics

  3. Head position and spinal position as determinants of perceived emotional state.

    Science.gov (United States)

    Schouwstra, S J; Hoogstraten, J

    1995-10-01

    A sample of 60 first-year psychology students judged the emotional state of 21 drawn figures and completed the Adjective Checklist and a mood questionnaire. The judgments were affected by the interaction between head position and spinal position of the figure. Each figure was associated with a unique pattern of emotions, and the judgments given were not influenced by the subjects' own emotional state.

  4. Nutrition and HIV-Positive Pregnancy

    Science.gov (United States)

    Montgomery, Kristen S.

    2003-01-01

    When an HIV-positive woman becomes pregnant, additional nutritional considerations are warranted. Compared to routine prenatal nutritional assessment and intervention, pregnant HIV-positive women have increased needs to promote a healthy outcome. This column contains information on HIV and pregnancy, nutrition and infection, and nutrition for HIV-positive pregnancy. This content can be integrated into childbirth education settings to improve care to women who are HIV-positive. PMID:17273329

  5. The Power of Positive Emotions

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español The Power of Positive Emotions KidsHealth / For Teens / The Power ... great one. 2. Practice Positivity Every Day Building habits that encourage us to feel more positive emotions ...

  6. Polyurethane - positioning aids in radiotherapy

    International Nuclear Information System (INIS)

    Alzen, G.; Boeck, E.G.; Thelen, M.; Kutzner, J.

    1985-01-01

    A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders. (orig.) [de

  7. What makes dreams positive or negative: relations to fundamental dimensions of positive and negative mood.

    Science.gov (United States)

    Kallmeyer, R J; Chang, E C

    1998-02-01

    The present study examined the general emotional content of dreams reported by individuals who typically experience "positive" versus "negative" dreams. Self-reports of the 153 participants indicated that positive versus negative dreamers (ns = 42 and 24, respectively) generally experienced more positive emotions, e.g., joviality, self-assurance, and fewer negative emotions, e.g., fear, sadness. No differences were found in the self-reports of the participants in the experience of surprise, guilt, fatigue, and shyness between the groups, hence, positive and negative dreams do not appear to reflect simply more positive and fewer negative emotions, respectively.

  8. A different perspective: introducing positive criminology.

    Science.gov (United States)

    Ronel, Natti; Elisha, Ety

    2011-04-01

    Positive criminology is a new conceptual perspective of criminology, encompassing several theories and models. Positive criminology refers to a focus on individuals' encounters with forces and influences that are experienced as positive, which distance them from deviance and crime, whether by means of formal and informal therapy programs and interventions, such as self-help groups; through emphasis of positive social elements, such as exposure to goodness, social acceptance, and reintegrative shaming; or based on positive personal traits, such as resilience and coherence. The perspective of positive criminology broadens that of traditional criminology, which focuses mainly on understanding the factors and processes that lead individuals and groups to what is defined as deviant and criminal behavior. Positive criminology is implemented in treatment and rehabilitation of individuals and groups that have demonstrated deviant and criminal behavior, by emphasizing positive experiences that may potentially prevent or discourage continued criminal behavior. Positive criminology is also expressed in prevention based on a positive approach.

  9. Ego depletion and positive illusions: does the construction of positivity require regulatory resources?

    Science.gov (United States)

    Fischer, Peter; Greitemeyer, Tobias; Frey, Dieter

    2007-09-01

    Individuals frequently exhibit positive illusions about their own abilities, their possibilities to control their environment, and future expectations. The authors propose that positive illusions require resources of self-control, which is considered to be a limited resource similar to energy or strength. Five studies revealed that people with depleted self-regulatory resources indeed exhibited a less-optimistic sense of their own abilities (Study 1), a lower sense of subjective control (Study 2), and less-optimistic expectations about their future (Study 3). Two further studies shed light on the underlying psychological process: Ego-depleted (compared to nondepleted) individuals generated/retrieved less positive self-relevant attributes (Studies 4 and 5) and reported a lower sense of general self-efficacy (Study 5), which both partially mediated the impact of ego depletion on positive self-views (Study 5).

  10. No praise, please: Depressive symptoms, reactivity to positive social interaction, and fear of positive evaluation.

    Science.gov (United States)

    Reichenberger, Julia; Wiggert, Nicole; Agroskin, Dmitrij; Wilhelm, Frank H; Blechert, Jens

    2017-03-01

    Depression is characterized by depressed mood and loss of interest or pleasure. Resulting alterations in emotional reactivity have been explained by three different accounts: 'positive attenuation', 'negative potentiation', and 'emotion context insensitivity'. Despite the importance of depression-related emotional alteration in social interactions, research with naturalistic interpersonal stimuli is scarce and underlying mechanisms largely unknown. Hence, the present study examined subjective emotional reactivity to brief negative, positive, and neutral social-evaluative videos as a function of depressive symptoms in an adult sample (N = 84). Fear of positive evaluation (FPE) and fear of negative evaluation (FNE), often conceptualized as cognitive components of social anxiety, were examined as possible mediators. Results revealed that more depression symptoms were related to diminished pleasantness responses to both positive and neutral videos. When considering all three video conditions simultaneously, only responses to positive videos remained significantly related to depression scores, supporting the 'positive attenuation' account. Moreover, FPE was found to uniquely mediate the relationship between depressive symptoms and pleasantness responses to positive videos. Results indicate that emotional reactivity to positive interpersonal stimuli is relevant for theoretical and clinical considerations of depression. This research underlines the importance of FPE not only for understanding social anxiety but also depression. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. The Role of Positive Emotion and Contributions of Positive Psychology in Depression Treatment: Systematic Review

    Science.gov (United States)

    Santos, Veruska; Paes, Flavia; Pereira, Valeska; Arias-Carrión, Oscar; Silva, Adriana Cardoso; Carta, Mauro Giovanni; Nardi, Antonio Egidio; Machado, Sergio

    2013-01-01

    The present study aims to conduct a systematic review of the literature by checking the impact of positive emotion in the treatment of depression and on the use of strategies of positive psychology which involves positive emotion to treat and reduce symptoms of depression. For this purpose, we conducted searches in databases ISI Web of Knowledge, PsycINFO and PubMed and found a total of 3400 studies. After inclusion application and exclusion criteria, 28 articles remained, presented and discussed in this study. The studies have important relations between humor and positive emotion as well as a significant improvement in signs and symptoms of depression using differents strategies of positive psychology. Another relevant aspect is the preventative character of the proposed interventions by positive psychology by the fact that increase well-being and produce elements such as resilience and coping resources that reduce the recurrent relapses in the treatment of depression. The strategies of positive psychology, such as increasing positive emotions, develop personal strengths: seeking direction, meaning and engagement for the day-to-day life of the patients, appear as potentially tools for the prophylaxis and treatment of depression, helping to reduce signs and symptoms as well as for prevention of relapses. PMID:24358052

  12. THE LIMITS OF POSITIVE INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    Gonzalo Hervás

    2017-01-01

    Full Text Available Positive interventions have been developed extensively in recent years and they have been tested and applied in very diverse settings. Despite the fact that most of the findings regarding their efficacy can be considered from positive to very positive, the possibility that, in some cases, positive interventions may have unexpected or even iatrogenic effects cannot be discarded. In this article, research from several sources is reviewed in order to inform decisions about what interventions might be inadequate for cases with specific characteristics or vulnerability traits. Finally, the importance of using positive interventions with caution and rigor even when working with individuals who do not have overt problems or psychological disorders is discussed.

  13. A-KAM, bracket positioning device

    Directory of Open Access Journals (Sweden)

    Anand Ambekar

    2018-01-01

    Full Text Available Bracket positioning is the heart of preadjusted edgewise appliance. Accuracy of bracket positioning directly affects the treatment outcome. A number of hand-held instruments are available for bracket positioning accuracy including Boon's gauge, MBT gauges, and various other modifications. However, the most commonly used MBT gauges come in a set of two or four jigs with gauges on each end of the instrument making it difficult to carry in the instrument tray for the orthodontists. Our new bracket positioning instrument, A-KAM, bracket positioning device surpasses these difficulties and can be used for reproducible bracket placement from 2.5 mm to 5.5 mm from the base of bracket.

  14. Corporate brand positioning : searching for a new position - case Metso Power

    OpenAIRE

    KUURU, TIINA-KAISA

    2013-01-01

    Tutkielmasta TamPubissa rajattu versio. Täydellinen versio luettavissa Tampereen yliopiston Linna-kirjastossa. This is a limited version of the Master's thesis. The complete version can be viewed in print at Tampere University Library The purpose of this study is to describe and analyse the process of corporate brand positioning. Study is focused on B2B market, precisely on industrial brands. Corporate brand positioning is defined as a process of searching and finding a...

  15. Collective Behaviour: Physiology Determines Position.

    Science.gov (United States)

    Krause, Jens; Seebacher, Frank

    2018-04-23

    An animal's position within a group affects feeding - front positions generally offer richer pickings. However, a new study shows that position can be influenced by feeding because big meals reduce scope for locomotion. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  16. The added value of the positive : A literature review of positive psychology interventions in organizations

    NARCIS (Netherlands)

    Meyers, M.C.; van Woerkom, M.; Bakker, A.

    2013-01-01

    This paper systematically reviews research investigating the effects of positive psychology interventions applied in the organizational context. We characterize a positive psychology intervention as any intentional activity or method that is based on (a) the cultivation of positive subjective

  17. Embryonic and foetal Islet-1 positive cells in human hearts are also positive to c-Kit

    Directory of Open Access Journals (Sweden)

    C. Serradifalco

    2011-12-01

    Full Text Available During embryogenesis, the mammalian heart develops from a primitive heart tube originating from two bilateral primary heart fields located in the lateral plate mesoderm. Cells belongings to the pre-cardiac mesoderm will differentiate into early cardiac progenitors, which express early transcription factors which are also common to the Isl-1 positive cardiac progenitor cells isolated from the developing pharyngeal mesoderm and the foetal and post-natal mice hearts. A second population of cardiac progenitor cells positive to c-Kit has been abundantly isolated from adult hearts. Until now, these two populations have been considered two different sets of progenitor cells present in the heart in different stages of an individual life. In the present study we collected embryonic, foetal and infant hearts, and we tested the hypotheses that c-Kit positive cells, usually isolated from the adult heart, are also present in the intra-uterine life and persist in the adult heart after birth, and that foetal Isl-1 positive cells are also positive to c-Kit. Using immunohistochemistry we studied the temporal distribution of Isl-1 positive and c-Kit/CD105 double positive cells, and by immunofluorescence and confocal analysis we studied the co-localization of c-Kit and Isl-1 positive cells. The results indicated that cardiomyocytes and interstitial cells were positive for c-Kit from the 9th to the 19th gestational week, that cells positive for both c-Kit and CD105 appeared in the interstitium at the 17th gestational week and persisted in the postnatal age, and that the Isl-1 positive cells were a subset of the c-Kit positive population.

  18. POSITIONING STRATEGIES DEVELOPMENT

    OpenAIRE

    Shakhshir Ghassan

    2014-01-01

    The positioning strategy has suffered serious changes in the last few decades, being influenced by the rapid development of competition and the growing focus on specific traits belonging to the market, to the consumer or to the product. The purpose of this paper is to present the developments of theoretical positioning strategies and the orientation from more simple, product oriented strategies, to ones more oriented towards the client and with a briefer period of time. The world is moving in...

  19. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives

    NARCIS (Netherlands)

    Wolf, M.; Kurvers, R.H.J.M.; Ward, A.J.W.; Krause, S.; Krause, J.

    2013-01-01

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives;

  20. Interaction of a vacuum arc plasma beam with an obstacle positioned normal to the plasma flow

    International Nuclear Information System (INIS)

    Zarchin, O; Zhitomirsky, V N; Goldsmith, S; Boxman, R L

    2003-01-01

    The effect of an obstacle positioned normal to a plasma jet produced by a vacuum arc plasma source on the radial distribution of ion flux in the vicinity of the obstacle was studied. This study was motivated by interest in the mutual influence of tightly packed substrates on coatings in industrial vacuum arc deposition systems. The experimental system consisted of a vacuum arc plasma source, a straight plasma duct, and a multi-probe consisting of a removable disc obstacle and a set of ring probes for measuring the radial ion flux. A dc arc discharge was ignited in vacuum between a truncated cone-shaped Cu cathode and an annular anode. The plasma jet produced by cathode spots passed through the anode aperture into the straight plasma duct. An axial magnetic field guided the plasma jet in the duct. The multi-probe consisted of a removable disc obstacle and a set of five ring probes for measuring the radial plasma flux as a function of distance from the disc obstacle. The rings and the disc probes were coaxially arranged on the multi-probe assembly and positioned so that plasma from the source passed through the ring probes and then encountered the disc. The influence of the obstacle was determined by measuring the ring ion currents, both in the presence of the obstacle, and when the disc obstacle was removed. The difference between the measured ion currents with and without the obstacle was interpreted to be the contribution of reflected or sputtered particles from the obstacle to the radial ion flux. The ring probes were biased by -60 V with respect to the grounded anode, to collect the saturated ion current. The multi-probe was connected to a movable stem, and positioned at different distances from the plasma source. A plasma density of ∼6 x 10 17 m -3 was estimated in this study based on the ion current to the obstacle. The radial ion flux collected by the ring probes increased by 20-25% due to the presence of the obstacle. As the calculated mean free path for

  1. Position indication apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, T

    1964-02-24

    A plurality of magnetically operated switches are spaced equally in the hollow tube of a control rod actuating mechanism. One side of each switch is connected, via a low resistance, to a corresponding tap of a low resistance voltage divider network consisting of an equivalent number of low resistance sections with the opposite side of each switch connected to a common conducting wire A. To both ends of the voltage dividing network are connected, respectively, conducting wires B and C. Wires A, B, and C are further coupled to a fuel rod position indicator comprising a voltmeter and power source external to the control rod actuating member. The control rod actuating member is adapted to slide in the hollow tube so that switches passing a position facing a magnet secured to the lower end of the actuating member are rendered closed. Hence, the position of the control rod may be read by reading the voltage off the meter.

  2. Introducing Positive Psychology to SLA

    Science.gov (United States)

    MacIntyre, Peter D.; Mercer, Sarah

    2014-01-01

    Positive psychology is a rapidly expanding subfield in psychology that has important implications for the field of second language acquisition (SLA). This paper introduces positive psychology to the study of language by describing its key tenets. The potential contributions of positive psychology are contextualized with reference to prior work,…

  3. 3 Ways to Increase Positive Emotions

    Science.gov (United States)

    ... Search English Español 3 Ways to Increase Positive Emotions KidsHealth / For Teens / 3 Ways to Increase Positive ... to give yourself a boost. Track Your Positive Emotions Name the positive emotions you're already familiar ...

  4. Positive affect and markers of inflammation: discrete positive emotions predict lower levels of inflammatory cytokines.

    Science.gov (United States)

    Stellar, Jennifer E; John-Henderson, Neha; Anderson, Craig L; Gordon, Amie M; McNeil, Galen D; Keltner, Dacher

    2015-04-01

    Negative emotions are reliably associated with poorer health (e.g., Kiecolt-Glaser, McGuire, Robles, & Glaser, 2002), but only recently has research begun to acknowledge the important role of positive emotions for our physical health (Fredrickson, 2003). We examine the link between dispositional positive affect and one potential biological pathway between positive emotions and health-proinflammatory cytokines, specifically levels of interleukin-6 (IL-6). We hypothesized that greater trait positive affect would be associated with lower levels of IL-6 in a healthy sample. We found support for this hypothesis across two studies. We also explored the relationship between discrete positive emotions and IL-6 levels, finding that awe, measured in two different ways, was the strongest predictor of lower levels of proinflammatory cytokines. These effects held when controlling for relevant personality and health variables. This work suggests a potential biological pathway between positive emotions and health through proinflammatory cytokines. (c) 2015 APA, all rights reserved).

  5. a Continuous-Time Positive Linear System

    Directory of Open Access Journals (Sweden)

    Kyungsup Kim

    2013-01-01

    Full Text Available This paper discusses a computational method to construct positive realizations with sparse matrices for continuous-time positive linear systems with multiple complex poles. To construct a positive realization of a continuous-time system, we use a Markov sequence similar to the impulse response sequence that is used in the discrete-time case. The existence of the proposed positive realization can be analyzed with the concept of a polyhedral convex cone. We provide a constructive algorithm to compute positive realizations with sparse matrices of some positive systems under certain conditions. A sufficient condition for the existence of a positive realization, under which the proposed constructive algorithm works well, is analyzed.

  6. Fluorescent optical position sensor

    Science.gov (United States)

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  7. Indoor Positioning using Wi-Fi

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Krarup, Mads Vering; Stisen, Allan

    The past decade has witnessed substantial research on methods for indoor Wi-Fi positioning. While much effort has gone into achieving high positioning accuracy and easing fingerprint collection, it is our contention that the general problem is not sufficiently well understood, thus preventing...... deployments and their usage by applications to become more widespread. Based on our own and published experiences on indoor Wi-Fi positioning deployments, we hypothesize the following: Current indoor Wi-Fi positioning systems and their utilization in applications are hampered by the lack of understanding...... of the requirements present in the real-world deployments. In this paper, we report findings from qualitatively studying organisational requirements for indoor Wi-Fi positioning. The studied cases and deployments cover both company and public-sector settings and the deployment and evaluation of several types...

  8. Strategic positioning. Part 2: Positioning challenges in an evolving health care marketplace.

    Science.gov (United States)

    Kauer, R T; Berkowitz, E

    1997-01-01

    Why is strategic positioning so important to health care organizations struggling in a managed care environment and what are the sources of value? In Part 1 of this article, entitled "The Sources of Value under Managed Care," the authors presented four sources of value relative to the evolution of the market from fee-for-service to managed care. These value sources are: (1) assets, (2) price/performance, (3) distribution, and, ultimately, (4) capabilities and brand equity. In this article, the authors further elaborate on the sources of value as the market moves beyond the historical fee-for-service position to a managed care marketplace. Part 2 presents the marketing and financial challenges to organizational positioning and performance across the four stages of managed care.

  9. On-line system for control of plasma filament position in the Tokamak-10

    International Nuclear Information System (INIS)

    Britousov, N.N.; Valuev, S.F.; Sychev, G.I.; Shchedrov, V.M.

    1982-01-01

    The plasma filament position on-line control system (OCS) in the T-10 tokamak is described. Results of adjustment and operation of the system are given. The OCS is a structure of a direct negative feedback (DNF) versus deflection and a local DNF circuit. The OCS experimental studying is carried out under the following conditions: 200 kA plasma current, 32 cm diaphragm radius, 2.2-2.5 stability margin, 440 V anode voltage. The response time for 2 cm deflection jumps is 15-20 ns. The OCS demonstrated a particular efficiency while operating in parallel with the plasma current stabilizer providing a high discharge repetition and considerably reducing the number of substandard pulses

  10. Study of positioning techniques for radiography

    International Nuclear Information System (INIS)

    Maruyama, Toshinori; Yamamoto, Hideki

    2008-01-01

    A good positioning technique is of great importance in radiology in order to obtain accurate diagnostic information and reduce the patient's X-ray exposure. In positioning training, students place the phantom on the table under an X-ray tube, adjust the position of the phantom, and repeat the positioning practices until they can obtain fine diagnostic images. As X-ray films are usually used in radiography, the development of such films is necessary. In this kind of training practice, it takes a great deal of time to obtain the X-ray image at the phantom position. It is desirable for students to perform positioning accurately and to confirm the results of positioning within a short time. In this article, we propose a new positioning training method using digital image processing. First, we scan the skull phantom by CT (computed tomography) and obtain CT images. Next, we measure the positioning information of the phantom under the X-ray equipment by using scene analysis. Then, we develop a method that produces the plane image corresponding to the detected phantom position under the X-ray tube. It is expected that our method will be useful as a teaching device to help in the practice of the positioning techniques for various organs without X-ray exposure and, furthermore, in the development of X-ray films. (author)

  11. Anodal vs cathodal stimulation of motor cortex: a modeling study

    NARCIS (Netherlands)

    Manola, L.; Holsheimer, J.; Veltink, Petrus H.; Buitenweg, Jan R.

    Objective. To explore the effects of electrical stimulation performed by an anode, a cathode or a bipole positioned over the motor cortex for chronic pain management. Methods. A realistic 3D volume conductor model of the human precentral gyrus (motor cortex) was used to calculate the

  12. Positional Concerns and Institutions

    DEFF Research Database (Denmark)

    Landes, Xavier

    2013-01-01

    that invoking envy or subjective well-being is not fully satisfying for regulating positional concerns. More compelling reasons seem, in complement with efficiency, to be related to considerations for equality. In other words, if institutions could have strong reasons to pay attention to and regulate positional...... their implications for economics, positional concerns imply important normative dimensions. There have been presumed to be a symptom of envy, reduce people’s happiness, and create problems of social interaction or economic inefficiencies. Individuals are, for instance, prone to pick states of the world that improve...... concerns, it would be in virtue of their impact on the social product and individuals’ conditions of living....

  13. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  14. Evaluation of the space scattered dose according to the position of the radiation workers in mammography room

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dept. of Radiation Oncology, Dongnam Inst. of Radiological and Medical Science, Busan (Korea, Republic of); Lee, Jin Soo [Dept. of Radiology, Inje University Heaundae Paik Hospital, Busan (Korea, Republic of)

    2016-09-15

    This study was conducted to evaluate the dose of the space to the controller located within the mammography room conducted a research on ways to the reduction exposure to the radiation workers. Results, the dose of 6.18 mGy/year was measured when there is no difference in the hilar area of the controller position, the dose of 2.35E-11 mGy/year was measured when installing the Shielding door. In addition, when the direction of the X-ray tube anode be heading this direction controller, low average level measured was 0.30 mGy/year. Based on this study, the mammography should be considered when installing the anode and cathod directions. And, by installing the shielding door, it must be able to completely separate shooting space and control room. This is the best way radiation protection method in radiation workers.

  15. Introducing positive psychology to SLA

    Directory of Open Access Journals (Sweden)

    Sarah Mercer

    2014-01-01

    Full Text Available Positive psychology is a rapidly expanding subfield in psychology that has important implications for the field of second language acquisition (SLA. This paper introduces positive psychology to the study of language by describing its key tenets. The potential contributions of positive psychology are contextualized with reference to prior work, including the humanistic movement in language teaching, models of motivation, the concept of an affective filter, studies of the good language learner, and the concepts related to the self. There are reasons for both encouragement and caution as studies inspired by positive psychology are undertaken. Papers in this special issue of SSLLT cover a range of quantitative and qualitative methods with implications for theory, research, and teaching practice. The special issue serves as a springboard for future research in SLA under the umbrella of positive psychology.

  16. Positive Youth Psychology: Lessons from Positive Peer Culture

    Science.gov (United States)

    Steinebach, Christoph; Steinebach, Ursula; Brendtro, Larry K.

    2013-01-01

    Positive Peer Culture (PPC) is a strength-oriented approach developed by Vorrath and Brendtro (1985) to prevent or reverse negative peer influence by building a climate of peer concern and respect. PPC operates in a range of settings including residential treatment, alternative schools, juvenile justice, and youth leadership groups. It is an…

  17. Positional reference system for ultraprecision machining

    International Nuclear Information System (INIS)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1982-01-01

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlledmultiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base

  18. Positional reference system for ultraprecision machining

    Science.gov (United States)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  19. Sensorless SPMSM Position Estimation Using Position Estimation Error Suppression Control and EKF in Wide Speed Range

    Directory of Open Access Journals (Sweden)

    Zhanshan Wang

    2014-01-01

    Full Text Available The control of a high performance alternative current (AC motor drive under sensorless operation needs the accurate estimation of rotor position. In this paper, one method of accurately estimating rotor position by using both motor complex number model based position estimation and position estimation error suppression proportion integral (PI controller is proposed for the sensorless control of the surface permanent magnet synchronous motor (SPMSM. In order to guarantee the accuracy of rotor position estimation in the flux-weakening region, one scheme of identifying the permanent magnet flux of SPMSM by extended Kalman filter (EKF is also proposed, which formed the effective combination method to realize the sensorless control of SPMSM with high accuracy. The simulation results demonstrated the validity and feasibility of the proposed position/speed estimation system.

  20. Sleep position trainer versus tennis ball technique in positional obstructive sleep apnea syndrome

    NARCIS (Netherlands)

    Eijsvogel, Michiel M.; Ubbink, Rinse; Dekker, Janita; Mos-Oppersma, Eline; de Jongh, Franciscus H.C.; van der Palen, Jacobus Adrianus Maria; Brusse-Keizer, Marjolein G.J.

    2015-01-01

    Study Objective Positional therapy (PT) is an effective therapy in positional obstructive sleep apnea syndrome (POSAS) when used, but the compliance of PT is low. The objective of this study was to investigate whether a new kind of PT is effective and can improve compliance. Methods 29 patients were

  1. Taking a radical position: Evidence for position specific radical representations in Chinese character recognition using masked priming ERP

    Directory of Open Access Journals (Sweden)

    I-Fan eSu

    2012-09-01

    Full Text Available In the investigation of orthographic representation of Chinese characters, one question that has stimulated much research is whether radicals (character components are specified for spatial position in a character (e.g. Ding, Peng, & Taft, 2004; Tsang & Chen, 2009. Differing from previous work, component or radical position information in this study is conceived in terms of relative frequency across different positions of characters containing it. A lexical decision task in a masked priming paradigm focusing on radicals with preferred position of occurrence was conducted. A radical position that encompasses more characters than other positions was identified to be the preferred position of a particular radical. The prime that was exposed for 96ms might share a radical with the target in the same or different positions. Moreover, the shared radical appeared either in its preferred or non-preferred position in the target. While response latencies only revealed the effect of graphical similarity, both effects of graphical similarity and radical position preference were found in the ERP results. The former effect was reflected in greater positivity in occipital P1 and greater negativity in N400 for radicals in different positions in prime and target characters. The latter effect manifested as greater negativity in occipital N170 and greater positivity in frontal P200 in the same time window elicited by radicals in their non-preferred position. Equally interesting was the reversal of the effect of radical position preference in N400 with greater negativity associated with radicals in preferred position. These findings identify the early ERP components associated with activation of position-specific radical representations in the orthographic lexicon, and reveal the change in the nature of competition from processing at the radical level to the lexical level.

  2. Researcher Positioning

    DEFF Research Database (Denmark)

    Khawaja, Iram; Mørck, Line Lerche

    2009-01-01

    involvement by the researcher, which challenges traditional perspectives onresearch and researcher positioning. A key point in this regard is the importance ofconstant awareness of and reflection on the multiple ways in which one's positioningas a researcher influences the research process. Studying the other...

  3. Controlling the occurrence of power overshoot by adapting microbial fuel cells to high anode potentials

    KAUST Repository

    Zhu, Xiuping

    2013-04-01

    Power density curves for microbial fuel cells (MFCs) often show power overshoot, resulting in inaccurate estimation of MFC performance at high current densities. The reasons for power overshoot are not well understood, but biofilm acclimation and development are known factors. In order to better explore the reasons for power overshoot, exoelectrogenic biofilms were developed at four different anode potentials (-0.46 V, -0.24 V, 0 V, and 0.50 V vs. Ag/AgCl), and then the properties of the biofilms were examined using polarization tests and cyclic voltammetry (CV). The maximum power density of the MFCs was 1200±100 mW/m2. Power overshoot was observed in MFCs incubated at -0.46 V, but not those acclimated atmore positive potentials, indicating that bacterial activitywas significantly influenced by the anode acclimation potential. CV results further indicated that power overshoot of MFCs incubated at the lowest anode potential was associatedwith a decreasing electroactivity of the anodic biofilm in the high potential region,which resulted from a lack of sufficient electron transfer components to shuttle electrons at rates needed for these more positive potentials. © 2012 Elsevier B.V.

  4. Den positive psykologis metoder

    DEFF Research Database (Denmark)

    Andersen, Frans Ørsted; Mørck, Line Lerche; Nissen, Poul Erik

    En antologi der giver en introduktion til en række af de metoder der anvendes til forskning, assessment, test, udviklingsarbejde og intervention indenfor den positive psykologi.......En antologi der giver en introduktion til en række af de metoder der anvendes til forskning, assessment, test, udviklingsarbejde og intervention indenfor den positive psykologi....

  5. Logotherapy and positive psychology

    Directory of Open Access Journals (Sweden)

    Oscar R. Oro

    2015-09-01

    Full Text Available Psychology omitted to approach, during almost a century, the positive aspects from persons, like creativity, humor, optimism, hope, forgiveness, life meaning, and happiness. These themes are approached by Positive Psychology, with Seligman like the principal exponent. Psychology was dedicated to explore the negative aspects from human beings improving human health. Nevertheless, this pathogenic model could not prevent mental disease. Concepts of Positive Psychology have a solid antecedent in Víktor Frankl ́s studies, which is the Logotherapy founder. This allows incorporating another perspective to approach positive aspects, from a philosophical and anthropological focus. Although the ways adopted by Frank and Seligman are different, both considered main aspects of human existence. Nevertheless, they investigated in different countries (from Europe and EE.UU.; in different circumstances (concentration camps, deaths, tortures; vs. academic context; in different historical periods and different social contexts (a country that lost the war and other that gave freedom to Europeans. In this work is used the concept life sense as the focus in professional formation and psychotherapy approach. 

  6. Sleep position trainer versus tennis ball technique in positional obstructive sleep apnea syndrome

    NARCIS (Netherlands)

    Eijsvogel, Michiel M.; Ubbink, Rinse; Dekker, Janita; Oppersma, Eline; de Jongh, Frans H.; van der Palen, Job; Brusse-Keizer, Marjolein G.

    2015-01-01

    Positional therapy (PT) is an effective therapy in positional obstructive sleep apnea syndrome (POSAS) when used, but the compliance of PT is low. The objective of this study was to investigate whether a new kind of PT is effective and can improve compliance. 29 patients were treated with the Sleep

  7. Effect of Positive Training on Positive Psychological States (Character Strengths of Female High School Students

    Directory of Open Access Journals (Sweden)

    Ali Farnam

    2017-05-01

    Full Text Available psychological states of female students in second and third grades of high school. The research method was quasi-experimental with pre-test, post-test and follow-up. The sample consisted of forty students selected randomly in two groups (twenty students in each group. To collect data, Positive Psychological State Inventory (Rajaei, Khuy Nzhad and Nesaei was used. The experimental group received ninety minute positive training sessions (for two months and the control group did not receive treatment. The results of analysis  of covariance showed that positive training had positive effects on positive psychological states (trust in God, optimism, self-efficacy, duty, sense of control, targeted, hope, satisfaction with life, meaningful life, pleasant, sociability, self-esteem and self-worth, sense of peace, gratitude, and forgiveness among adolescents  both in the post  and follow-up tests

  8. Grounds of two positions photovoltaic panels

    OpenAIRE

    Castán Fortuño, Fernando

    2008-01-01

    The objective of this Master Thesis is to find the optimum positioning for a two positions photovoltaic panel. Hence, it will be implemented a model in order to optimize the energy of the sun that the photovoltaic panel is receiving by its positioning. Likewise this project will include the comparison with other photovoltaic panel systems as the single position photovoltaics panels. Ultimately, it is also going to be designed a system array for the optimized model of two positions photovoltai...

  9. Ventilator-associated pneumonia: role of positioning.

    Science.gov (United States)

    Li Bassi, Gianluigi; Torres, Antoni

    2011-02-01

    Ventilator-associated pneumonia (VAP) is a lung infection commonly acquired following tracheal intubation. This review assesses the role of the supine semirecumbent and the prone position as VAP preventive strategies and calls attention for further investigation on novel body positions that could potentially reduce risks of VAP. The most recent studies on the semirecumbent position failed to achieve an orientation of the head of the bed higher than 30° and did not corroborate any benefit of the semirecumbent position on VAP, as reported in earlier studies. To date, there is clear evidence that the supine horizontal body position increases risks of pulmonary aspiration and VAP, particularly when patients are enterally fed. Laboratory reports are emphasizing the importance of an endotracheal tube-oropharynx-trachea axis below horizontal to avoid VAP. The prone position potentially increases drainage of oropharyngeal and airways secretions and recent evidence is supporting its beneficial effects. However, several associated adverse effects preclude its regular use as a VAP preventive strategy for patients other than those with acute respiratory distress syndrome. Body position greatly affects several pathogenetic mechanisms of VAP. The current evidence recommends avoidance of supine horizontal position in order to prevent aspiration of colonized gastric contents. The semirecumbent position has proven benefits and should be routinely used but there is still limited evidence to recommend the lowest orientation of the bed at which the patient can be safely maintained. Results from pioneering laboratory investigation call attention to new possible positions, that is lateral Trendelenburg position, aimed to avoid pulmonary aspiration and to enhance mucus clearance in intubated patients.

  10. MDEP Common Position CP-DICWG-13. Common position on spurious actuation

    International Nuclear Information System (INIS)

    2017-01-01

    Spurious actuations produced by Instrumentation and Control (I and C) systems are a safety concern if such actuations could challenge plant safety. Spurious actuations can lead to unnecessary challenges to safety equipment, challenge the ability of safety systems to provide their intended functions, or place the plant in an un-analysed state. Spurious actuation of plant equipment can be caused by factors including, but not limited to, single failures, common cause failures, human (e.g. operator) action, maintenance errors, design errors, or missing requirements. Modern I and C systems can have inter-connectivities, dependencies and commonalities that can, if the overall I and C architecture and the individual I and C systems are not adequately developed and operated, facilitate fault propagation, leading to potential spurious actuation of one or more trains of plant equipment. Sources and contributors of spurious actuations of multiple trains of plant equipment may include inadequate independence among redundant portions of I and C systems, inappropriate allocation of I and C functions, inadequate qualification or design of supporting systems (e.g. heating, ventilation and air conditioning (HVAC) system), or non-classified systems that could have been erroneously classified. Spurious actuations are a type of hazard. Generic Common Position (GCP) DICWG-10 'Common Position on Hazard Identification and Controls for Digital Instrumentation and Control Systems' provides a set of common positions pertaining to identifying and controlling hazards in an I and C system. This common position was developed to add special considerations when identifying and controlling hazards that include spurious actuations. It is expected that GCP DICWG-10 and the common positions in this document be used together for a complete analysis of hazards and their controls (e.g. prevention of spurious actuations in the design of the system/component). Spurious actuations of concern

  11. Variable-Position Acoustic Levitation

    Science.gov (United States)

    Barmatz, M. B.; Stoneburner, J. D.; Jacobi, N.; Wang, T. G.

    1983-01-01

    Method of acoustic levitation supports objects at positions other than acoustic nodes. Acoustic force is varied so it balances gravitational (or other) force, thereby maintaining object at any position within equilibrium range. Levitation method applicable to containerless processing. Such objects as table-tennis balls, hollow plastic spheres, and balsa-wood spheres levitated in laboratory by new method.

  12. Platform Architecture for Decentralized Positioning Systems

    Directory of Open Access Journals (Sweden)

    Zakaria Kasmi

    2017-04-01

    Full Text Available A platform architecture for positioning systems is essential for the realization of a flexible localization system, which interacts with other systems and supports various positioning technologies and algorithms. The decentralized processing of a position enables pushing the application-level knowledge into a mobile station and avoids the communication with a central unit such as a server or a base station. In addition, the calculation of the position on low-cost and resource-constrained devices presents a challenge due to the limited computing, storage capacity, as well as power supply. Therefore, we propose a platform architecture that enables the design of a system with the reusability of the components, extensibility (e.g., with other positioning technologies and interoperability. Furthermore, the position is computed on a low-cost device such as a microcontroller, which simultaneously performs additional tasks such as data collecting or preprocessing based on an operating system. The platform architecture is designed, implemented and evaluated on the basis of two positioning systems: a field strength system and a time of arrival-based positioning system.

  13. Daily fluctuations in positive affect positively co-vary with working memory performance.

    Science.gov (United States)

    Brose, Annette; Lövdén, Martin; Schmiedek, Florian

    2014-02-01

    Positive affect is related to cognitive performance in multiple ways. It is associated with motivational aspects of performance, affective states capture attention, and information processing modes are a function of affect. In this study, we examined whether these links are relevant within individuals across time when they experience minor ups and downs of positive affect and work on cognitive tasks in the laboratory on a day-to-day basis. Using a microlongitudinal design, 101 younger adults (20-31 years of age) worked on 3 working memory tasks on about 100 occasions. Every day, they also reported on their momentary affect and their motivation to work on the tasks. In 2 of the 3 tasks, performance was enhanced on days when positive affect was above average. This performance enhancement was also associated with more motivation. Importantly, increases in task performance on days with above-average positive affect were mainly unrelated to variations in negative affect. This study's results are in line with between-person findings suggesting that high levels of well-being are associated with successful outcomes. They imply that success on cognitively demanding tasks is more likely on days when feeling happier. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  14. Positivity VII (Zaanen Centennial Conference)

    CERN Document Server

    Pagter, Ben; Gaans, Onno; Veraar, Mark

    2016-01-01

    This book presents the proceedings of Positivity VII, held from 22-26 July 2013, in Leiden, the Netherlands. Positivity is the mathematical field concerned with ordered structures and their applications in the broadest sense of the word. A biyearly series of conferences is devoted to presenting the latest developments in this lively and growing discipline. The lectures at the conference covered a broad spectrum of topics, ranging from order-theoretic approaches to stochastic processes, positive solutions of evolution equations and positive operators on vector lattices, to order structures in the context of algebras of operators on Hilbert spaces. The contributions in the book reflect this variety and appeal to university researchers in functional analysis, operator theory, measure and integration theory and operator algebras. Positivity VII was also the Zaanen Centennial Conference to mark the 100th birth year of Adriaan Cornelis Zaanen, who held the chair of Analysis in Leiden for more than 25 years and was ...

  15. Positivity for Convective Semi-discretizations

    KAUST Repository

    Fekete, Imre

    2017-04-19

    We propose a technique for investigating stability properties like positivity and forward invariance of an interval for method-of-lines discretizations, and apply the technique to study positivity preservation for a class of TVD semi-discretizations of 1D scalar hyperbolic conservation laws. This technique is a generalization of the approach suggested in Khalsaraei (J Comput Appl Math 235(1): 137–143, 2010). We give more relaxed conditions on the time-step for positivity preservation for slope-limited semi-discretizations integrated in time with explicit Runge–Kutta methods. We show that the step-size restrictions derived are sharp in a certain sense, and that many higher-order explicit Runge–Kutta methods, including the classical 4th-order method and all non-confluent methods with a negative Butcher coefficient, cannot generally maintain positivity for these semi-discretizations under any positive step size. We also apply the proposed technique to centered finite difference discretizations of scalar hyperbolic and parabolic problems.

  16. Positive psychiatry: its time has come.

    Science.gov (United States)

    Jeste, Dilip V; Palmer, Barton W; Rettew, David C; Boardman, Samantha

    2015-06-01

    Traditionally, psychiatry has been defined and practiced as a branch of medicine focused on the diagnosis and treatment of mental illnesses. Based on growing empirical evidence, we believe that this definition warrants expansion to include the concept of positive psychiatry. In the present article, we provide a critical overview of this emerging field and a select review of relevant scientific literature. Positive psychiatry may be defined as the science and practice of psychiatry that seeks to understand and promote well-being through assessment and interventions involving positive psychosocial characteristics (PPCs) in people who suffer from or are at high risk of developing mental or physical illnesses. It can also benefit nonclinical populations. Positive psychiatry has 4 main components: (1) positive mental health outcomes (eg, well-being), (2) PPCs that comprise psychological traits (resilience, optimism, personal mastery and coping self-efficacy, social engagement, spirituality and religiosity, and wisdom-including compassion) and environmental factors (family dynamics, social support, and other environmental determinants of overall health), (3) biology of positive psychiatry constructs, and (4) positive psychiatry interventions including preventive ones. There are promising empirical data to suggest that positive traits may be improved through psychosocial and biological interventions. As a branch of medicine rooted in biology, psychiatry, especially with the proposed conceptualization of positive psychiatry, is well poised to provide major contributions to the positive mental health movement, thereby impacting the overall health care of the population. © Copyright 2015 Physicians Postgraduate Press, Inc.

  17. Positive Psychiatry: Its Time Has Come

    Science.gov (United States)

    Jeste, Dilip V.; Palmer, Barton W.; Rettew, David C.; Boardman, Samantha

    2017-01-01

    Traditionally, psychiatry has been defined and practiced as a branch of medicine focused on the diagnosis and treatment of mental illnesses. Based on growing empirical evidence, we believe that this definition warrants expansion to include the concept of positive psychiatry. In the present article we provide a critical overview of this emerging field and a select review of relevant scientific literature. Positive psychiatry may be defined as the science and practice of psychiatry that seeks to understand and promote well-being through assessment and interventions involving positive psychosocial characteristics (PPCs) in people who suffer from or are at high risk of developing mental or physical illnesses. It can also benefit non-clinical populations. Positive psychiatry has 4 main components: (1) positive mental health outcomes (e.g., well-being), (2) PPCs that comprise psychological traits (resilience, optimism, personal mastery and coping self-efficacy, social engagement, spirituality and religiosity, and wisdom - including compassion) and environmental factors (family dynamics, social support, and other environmental determinants of overall health), (3) biology of positive psychiatry constructs, and (4) positive psychiatry Interventions including preventive ones. There are promising empirical data to suggest that positive traits may be improved through psychosocial and biological interventions. As a branch of medicine, rooted in biology, psychiatry, especially with the proposed conceptualization of positive psychiatry, is well poised to provide major contributions to the positive mental health movement, thereby impacting the overall healthcare of the population. PMID:26132670

  18. Beam position optimisation for IMRT

    International Nuclear Information System (INIS)

    Holloway, L.; Hoban, P.

    2001-01-01

    Full text: The introduction of IMRT has not generally resulted in the use of optimised beam positions because to find the global solution of the problem a time consuming stochastic optimisation method must be used. Although a deterministic method may not achieve the global minimum it should achieve a superior dose distribution compared to no optimisation. This study aimed to develop and test such a method. The beam optimisation method developed relies on an iterative process to achieve the desired number of beams from a large initial number of beams. The number of beams is reduced in a 'weeding-out' process based on the total fluence which each beam delivers. The process is gradual, with only three beams removed each time (following a small number of iterations), ensuring that the reduction in beams does not dramatically affect the fluence maps of those remaining. A comparison was made between the dose distributions achieved when the beams positions were optimised in this fashion and when the beams positions were evenly distributed. The method has been shown to work quite effectively and efficiently. The Figure shows a comparison in dose distribution with optimised and non optimised beam positions for 5 beams. It can be clearly seen that there is an improvement in the dose distribution delivered to the tumour and a reduction in the dose to the critical structure with beam position optimisation. A method for beam position optimisation for use in IMRT optimisations has been developed. This method although not necessarily achieving the global minimum in beam position still achieves quite a dramatic improvement compared with no beam position optimisation and is very efficiently achieved. Copyright (2001) Australasian College of Physical Scientists and Engineers in Medicine

  19. Positive Art Therapy: Linking Positive Psychology to Art Therapy Theory, Practice, and Research

    Science.gov (United States)

    Wilkinson, Rebecca A.; Chilton, Gioia

    2013-01-01

    As a growing movement in the larger field of mental health, positive psychology has much to offer the art therapy profession, which in turn is uniquely poised to contribute to the study of optimal functioning. This article discusses the relationship of positive psychology to art therapy and its capacity to mobilize client strengths, to induce…

  20. Positivity of the English Language

    Science.gov (United States)

    Kloumann, Isabel M.; Danforth, Christopher M.; Harris, Kameron Decker; Bliss, Catherine A.; Dodds, Peter Sheridan

    2012-01-01

    Over the last million years, human language has emerged and evolved as a fundamental instrument of social communication and semiotic representation. People use language in part to convey emotional information, leading to the central and contingent questions: (1) What is the emotional spectrum of natural language? and (2) Are natural languages neutrally, positively, or negatively biased? Here, we report that the human-perceived positivity of over 10,000 of the most frequently used English words exhibits a clear positive bias. More deeply, we characterize and quantify distributions of word positivity for four large and distinct corpora, demonstrating that their form is broadly invariant with respect to frequency of word use. PMID:22247779

  1. Positivity of the English language.

    Directory of Open Access Journals (Sweden)

    Isabel M Kloumann

    Full Text Available Over the last million years, human language has emerged and evolved as a fundamental instrument of social communication and semiotic representation. People use language in part to convey emotional information, leading to the central and contingent questions: (1 What is the emotional spectrum of natural language? and (2 Are natural languages neutrally, positively, or negatively biased? Here, we report that the human-perceived positivity of over 10,000 of the most frequently used English words exhibits a clear positive bias. More deeply, we characterize and quantify distributions of word positivity for four large and distinct corpora, demonstrating that their form is broadly invariant with respect to frequency of word use.

  2. Positioning health professional identity

    DEFF Research Database (Denmark)

    Lund, Ole; Krogh Christensen, Mette; Mørcke, Anne Mette

    2017-01-01

    Drawing on positioning theory, the purpose of this paper is to characterize the activities and positions of students and supervisors at workplaces and on-campus skills training sites across the higher health professional educations of medicine, sports science, and nursing. Furthermore, the study ...... explored the impact of work-based learning (WBL) and skills training on students’ personal professional identity development....

  3. Head and neck position sense.

    Science.gov (United States)

    Armstrong, Bridget; McNair, Peter; Taylor, Denise

    2008-01-01

    Traumatic minor cervical strains are common place in high-impact sports (e.g. tackling) and premature degenerative changes have been documented in sports people exposed to recurrent impact trauma (e.g. scrummaging in rugby) or repetitive forces (e.g. Formula 1 racing drivers, jockeys). While proprioceptive exercises have been an integral part of rehabilitation of injuries in the lower limb, they have not featured as prominently in the treatment of cervical injuries. However, head and neck position sense (HNPS) testing and re-training may have relevance in the management of minor sports-related neck injuries, and play a role in reducing the incidence of ongoing pain and problems with function. For efficacious programmes to be developed and tested, fundamental principles associated with proprioception in the cervical spine should be considered. Hence, this article highlights the importance of anatomical structures in the cervical spine responsible for position sense, and how their interaction with the CNS affects our ability to plan and execute effective purposeful movements. This article includes a review of studies examining position sense in subjects with and without pathology and describes the effects of rehabilitation programmes that have sought to improve position sense. In respect to the receptors providing proprioceptive information for the CNS, the high densities and complex arrays of spindles found in cervical muscles suggest that these receptors play a key role. There is some evidence suggesting that ensemble encoding of discharge patterns from muscle spindles is relayed to the CNS and that a pattern recognition system is used to establish joint position and movement. Sensory information from neck proprioceptive receptors is processed in tandem with information from the vestibular system. There are extensive anatomical connections between neck proprioceptive inputs and vestibular inputs. If positional information from the vestibular system is inaccurate or

  4. Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CT

    International Nuclear Information System (INIS)

    Hunjan, Sandeep; Starkschall, George; Prado, Karl; Dong Lei; Balter, Peter

    2010-01-01

    Purpose: For thoracic tumors, if four-dimensional computed tomography (4DCT) is unavailable, the internal margin can be estimated by use of breath-hold (BH) CT scans acquired at end inspiration (EI) and end expiration (EE). By use of external surrogates for tumor position, BH accuracy is estimated by minimizing the difference between respiratory extrema BH and mean equivalent-phase free breathing (FB) positions. We tested the assumption that an external surrogate for BH accuracy correlates with internal tumor positional accuracy during BH CT. Methods and Materials: In 16 lung cancer patients, 4DCT images, as well as BH CT images at EI and EE, were acquired. Absolute differences between BH and mean equivalent-phase (FB) positions were calculated for both external fiducials and gross tumor volume (GTV) centroids as metrics of external and internal BH accuracy, respectively, and the results were correlated. Results: At EI, the absolute difference between mean FB and BH fiducial displacement correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.11). Similarly, at EE, the absolute difference between mean FB and BH fiducial displacements correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.18). Conclusions: External surrogates for tumor position are not an accurate metric of BH accuracy for lung cancer patients. This implies that care should be taken when using such an approach because an incorrect internal margin could be generated.

  5. Assessment of preschoolers’ positive empathy: concurrent and longitudinal relations with positive emotion, social competence, and sympathy

    OpenAIRE

    Sallquist, Julie; Eisenberg, Nancy; Spinrad, Tracy L.; Eggum, Natalie D.; Gaertner, Bridget M.

    2009-01-01

    The purpose of this study was to examine a new measure of children’s dispositional positive empathy (i.e., reactions to others’ positive emotions) and its concurrent and longitudinal relations with positive emotion, social competence, and empathy/sympathy with negative emotions. At Time 1, 192 3.5-year-olds (88 girls) participated; at Time 2, 1 year later, 168 4.5-year-olds (79 girls) participated. Children’s positive empathy was reported by mothers and observed in the laboratory at Time 2. A...

  6. Do positive children become positive adults? Evidence from a longitudinal birth cohort study.

    Science.gov (United States)

    Richards, Marcus; Huppert, Felicia A

    2011-02-10

    BACKGROUND: Little is known about the long-term consequences of positive wellbeing in childhood in the general population. We used the MRC National Survey of Health and Development (the British 1946 birth cohort) to test associations between adolescent positive wellbeing and social functioning in midlife. METHOD: Temperament and behaviour at ages 13 and 15 years were rated by school teachers on a range of criteria. These mostly referred to absence or presence of conduct and emotional problems, but four items allowed positive ratings: 'very popular with other children', 'unusually happy and contented', 'makes friends extremely easily' and 'extremely energetic, never tired'. In addition, at age 16 years survey members self-completed the Maudsley Personality Inventory, from which a summary measure of extraversion was derived, as this was previously found to be associated with midlife positive wellbeing in this cohort. RESULTS: Being a happy child, defined as receiving at least two of the above teacher ratings, was positively associated with midlife functioning and wellbeing, specifically a low probability of lifetime emotional problems, a high frequency of contact with friends or relatives, engagement in social activities, and to a lesser extent feeling satisfied with accomplishments in working life. These associations were independent of father's social class, childhood cognition, educational attainment, and midlife occupational social class. There were no independent associations between being a happy child and educational or occupational attainment, being married, engagement in prosocial activities, taking leadership in community activities, and with life satisfaction in general or with family life. Extraversion was associated with a low probability of lifetime emotional problems, high engagement in social activities, being married, general midlife life satisfaction, and satisfaction with family life, but not with social contact, prosocial activity, leadership

  7. EEG Correlates of Ten Positive Emotions.

    Science.gov (United States)

    Hu, Xin; Yu, Jianwen; Song, Mengdi; Yu, Chun; Wang, Fei; Sun, Pei; Wang, Daifa; Zhang, Dan

    2017-01-01

    Compared with the well documented neurophysiological findings on negative emotions, much less is known about positive emotions. In the present study, we explored the EEG correlates of ten different positive emotions (joy, gratitude, serenity, interest, hope, pride, amusement, inspiration, awe, and love). A group of 20 participants were invited to watch 30 short film clips with their EEGs simultaneously recorded. Distinct topographical patterns for different positive emotions were found for the correlation coefficients between the subjective ratings on the ten positive emotions per film clip and the corresponding EEG spectral powers in different frequency bands. Based on the similarities of the participants' ratings on the ten positive emotions, these emotions were further clustered into three representative clusters, as 'encouragement' for awe, gratitude, hope, inspiration, pride, 'playfulness' for amusement, joy, interest, and 'harmony' for love, serenity. Using the EEG spectral powers as features, both the binary classification on the higher and lower ratings on these positive emotions and the binary classification between the three positive emotion clusters, achieved accuracies of approximately 80% and above. To our knowledge, our study provides the first piece of evidence on the EEG correlates of different positive emotions.

  8. A setup for measurement of beam stability and position using position sensitive detector for Indus-1

    International Nuclear Information System (INIS)

    Nathwani, R.K.; Joshi, D.K.; Tyagi, Y.; Soni, R.S.; Puntambekar, T.A.; Pithawa, C.K.

    2009-01-01

    The 450 MeV electron synchrotron radiation source Indus-1 is operational at RRCAT. A set-up has been developed to measure the relative transverse positional stability of the electron beam and its position with microns resolution using position sensitive photodiodes. The set-up has been installed at the diagnostics beam line of Indus-1. Synchrotron light from photo physics beamline was reflected out by inserting a Ni coated mirror and was focused onto a duo-lateral position sensitive photodiode by using two mirrors of 1.25 meter focal length to obtain unity magnification. The set-up consists of a duo-lateral position sensitive detector (PSD), precision processing electronics and a PC based data acquisition system. A computer program captures the processed signals on to a PC using GPIB interface and displays vertical position of the beam in real time. The paper describes the salient features of the setup developed for measurement of beam stability. (author)

  9. Position indicating device

    International Nuclear Information System (INIS)

    Fellchenfeld, M.M.; Connors, G.R.

    1987-01-01

    This patent describes a position indicating device for producing an indication of the position of a displaceable structure comprising: a position representing member mounted for movement in response to displacement of the structure; sensing elements spaced apart along the defined path such that each element is associated with a respective location along the defined path; means operatively coupling the elements into respective pairs of elements, having, for each pair of elements, an output producing a signal only when a single element of its respective pair is responding to the presence of the member; signal producing members each operative for producing a signal representing a predetermined logic state in response to a predetermined input signal, the number of the signal producing members being smaller than the number of the sensing elements; and circuit means operatively connecting the outputs to the signal producing members for causing a signal at each output to produce a predetermined input signal at a corresponding signal producing member and for causing a predetermined input signal to be produced at least one the signal producing member whenever a signal is present at either one of at least two of the outputs

  10. Eyeball Position in Facial Approximation: Accuracy of Methods for Predicting Globe Positioning in Lateral View.

    Science.gov (United States)

    Zednikova Mala, Pavla; Veleminska, Jana

    2018-01-01

    This study measured the accuracy of traditional and validated newly proposed methods for globe positioning in lateral view. Eighty lateral head cephalograms of adult subjects from Central Europe were taken, and the actual and predicted dimensions were compared. The anteroposterior eyeball position was estimated as the most accurate method based on the proportion of the orbital height (SEE = 1.9 mm) and was followed by the "tangent to the iris method" showing SEE = 2.4 mm. The traditional "tangent to the cornea method" underestimated the eyeball projection by SEE = 5.8 mm. Concerning the superoinferior eyeball position, the results showed a deviation from a central to a more superior position by 0.3 mm, on average, and the traditional method of central positioning of the globe could not be rejected as inaccurate (SEE = 0.3 mm). Based on regression analyzes or proportionality of the orbital height, the SEE = 2.1 mm. © 2017 American Academy of Forensic Sciences.

  11. Anode plasma dynamics in the self-magnetic-pinch diode

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2011-02-01

    Full Text Available The self-magnetic-pinch diode is being developed as an intense electron beam source for pulsed-power-driven x-ray radiography. In high-power operation, the beam electrons desorb contaminants from the anode surface from which positive ions are drawn to the cathode. The counterstreaming electrons and ions establish an equilibrium current. It has long been recognized, however, that expanding electrode plasmas can disrupt this equilibrium and cause rapid reduction of the diode impedance and the radiation pulse. Recently developed numerical techniques, which enable simultaneous modeling of particle currents with 10^{13}  cm^{-3} densities to plasmas of near solid density, are applied to a model of the self-magnetic-pinch diode which includes the formation and evolution of anode surface plasmas. Two mechanisms are shown to cause rapid impedance loss, anode plasma expansion into the anode-cathode (A-K gap, and increased ion space-charge near the cathode surface. The former mechanism dominates for shorter A-K gaps, while the latter dominates for longer gaps. Model results qualitatively reproduce the time-dependent impedances measured for this diode.

  12. Workaholism as positive social deviance

    OpenAIRE

    Belousov, Konstantin

    2014-01-01

    The article justifies a potential research of workaholism as a social phenomenon within the positive deviance approach. In this paper, the authors provide definitions of positive deviance by foreign and Russian scholars as well as analyse how such behaviors depart from the norms of a referent group and adduce a number of studies positively assessing the concept. Finally, the authors conclude that workaholism can be regarded as a supraconformal behavior that can boost economic, cultural and sc...

  13. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  14. Product Differentiation and Positioning: Confused Concepts

    OpenAIRE

    Shaheen Borna; Joseph Chapman

    1993-01-01

    This article examines two common marketing terms: product positioning and product differentiation. Many authors use these terms interchangeably, yet most marketing texts treat product positioning and product differentiation as two seperate concepts. This article attempts to identify the underlying concepts of both product differentiation and product positioning. Product differentiation is shown to be a special case of product positioning: therefore, it is suggested that marketers may want to ...

  15. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  16. Massive Galileon positivity bounds

    Science.gov (United States)

    de Rham, Claudia; Melville, Scott; Tolley, Andrew J.; Zhou, Shuang-Yong

    2017-09-01

    The EFT coefficients in any gapped, scalar, Lorentz invariant field theory must satisfy positivity requirements if there is to exist a local, analytic Wilsonian UV completion. We apply these bounds to the tree level scattering amplitudes for a massive Galileon. The addition of a mass term, which does not spoil the non-renormalization theorem of the Galileon and preserves the Galileon symmetry at loop level, is necessary to satisfy the lowest order positivity bound. We further show that a careful choice of successively higher derivative corrections are necessary to satisfy the higher order positivity bounds. There is then no obstruction to a local UV completion from considerations of tree level 2-to-2 scattering alone. To demonstrate this we give an explicit example of such a UV completion.

  17. Relativistic positioning systems: Numerical simulations

    Science.gov (United States)

    Puchades Colmenero, Neus

    The position of users located on the Earth's surface or near it may be found with the classic positioning systems (CPS). Certain information broadcast by satellites of global navigation systems, as GPS and GALILEO, may be used for positioning. The CPS are based on the Newtonian formalism, although relativistic post-Newtonian corrections are done when they are necessary. This thesis contributes to the development of a different positioning approach, which is fully relativistic from the beginning. In the relativistic positioning systems (RPS), the space-time position of any user (ship, spacecraft, and so on) can be calculated with the help of four satellites, which broadcast their proper times by means of codified electromagnetic signals. In this thesis, we have simulated satellite 4-tuples of the GPS and GALILEO constellations. If a user receives the signals from four satellites simultaneously, the emission proper times read -after decoding- are the user "emission coordinates". In order to find the user "positioning coordinates", in an appropriate almost inertial reference system, there are two possibilities: (a) the explicit relation between positioning and emission coordinates (broadcast by the satellites) is analytically found or (b) numerical codes are designed to calculate the positioning coordinates from the emission ones. Method (a) is only viable in simple ideal cases, whereas (b) allows us to consider realistic situations. In this thesis, we have designed numerical codes with the essential aim of studying two appropriate RPS, which may be generalized. Sometimes, there are two real users placed in different positions, which receive the same proper times from the same satellites; then, we say that there is bifurcation, and additional data are needed to choose the real user position. In this thesis, bifurcation is studied in detail. We have analyzed in depth two RPS models; in both, it is considered that the satellites move in the Schwarzschild's space

  18. Predictors of positive health in disability pensioners: a population-based questionnaire study using Positive Odds Ratio

    Directory of Open Access Journals (Sweden)

    Edén Lena

    2002-09-01

    Full Text Available Abstract Background Determinants of ill-health have been studied far more than determinants of good and improving health. Health promotion measures are important even among individuals with chronic diseases. The aim of this study was to find predictors of positive subjective health among disability pensioners (DPs with musculoskeletal disorders. Methods Two questionnaire surveys were performed among 352 DPs with musculoskeletal disorders. Two groups were defined: DPs with positive health and negative health, respectively. In consequence with the health perspective in this study the conception Positive Odds Ratio was defined and used in the logistic regression analyses instead of the commonly used odds ratio. Results Positive health was associated with age ≥ 55 years, not being an immigrant, not having fibromyalgia as the main diagnosis for granting an early retirement, no regular use of analgesics, a high ADL capacity, a positive subjective health preceding the study period, and good quality of life. Conclusion Positive odds ratio is a concept well adapted to theories of health promotion. It can be used in relation to positive outcomes instead of risks. Suggested health promotion and secondary prevention efforts among individuals with musculoskeletal disorders are 1 to avoid a disability pension for individuals

  19. Patient positioning and ventilator-associated pneumonia.

    Science.gov (United States)

    Hess, Dean R

    2005-07-01

    Rotational beds, prone position, and semi-recumbent position have been proposed as procedures to prevent ventilator-associated pneumonia (VAP). Rotational therapy uses a special bed designed to turn continuously, or nearly continuously, the patient from side to side; specific designs include kinetic therapy and continuous lateral rotation therapy. A meta-analysis of studies evaluating the effect of rotational bed therapy shows a decrease in the risk of pneumonia but no effect on mortality. Two studies reported a lower risk of VAP in patients placed in a prone position, with no effect on mortality. Studies using radiolabeled enteral feeding solutions in mechanically ventilated patients have reported that aspiration of gastric contents occurs to a greater degree when patients are in the supine position, compared with the semirecumbent position. One study reported a lower rate of VAP in patients randomized to semi-recumbent compared to supine position. Although each of the techniques discussed in this paper has been shown to reduce the risk of VAP, none has been shown to affect mortality. The available evidence suggests that semi-recumbent position should be used routinely, rotational therapy should be considered in selected patients, and prone position should not be used as a technique to reduce the risk of VAP.

  20. Design of precision position adjustable scoop

    International Nuclear Information System (INIS)

    Li Zhili; Zhang Kai; Dong Jinping

    2014-01-01

    In isotopes separation technologies, the centrifuge method has been the most popular technology now. Separation performance of centrifugal machines is greatly influenced by the flow field in the centrifugal machines. And the position of scoops in the centrifuges has a significant influence on the flow field. To obtain a better flow field characteristic and find the best position of scoops in the centrifuges, a position adjustable scoop system was studied. A micro stage and a linear encoder were used in the system to improve the position accuracy of the scoop. Eddy current sensors had been used in a position calibration measurement. The measurement result showed the sensitivity and stability of the position system could meet the performance expectation. But as the driving mean, the steel wire and pulley limit the control precision. On the basis of this scheme, an ultrasonic motor was used as driving mean. Experimental results showed the control accuracy was improved. This scheme laid a foundation to obtain internal flow field parameters of centrifuge and get the optimal feeding tube position. (authors)

  1. An overview of current developments in position-sensitive hybrid photon detectors and photo-multiplier tubes

    CERN Document Server

    Gys, Thierry

    1999-01-01

    Current developments in position-sensitive hybrid photon detectors and photo-multiplier tubes have stimulated increased interest from a variety of fields such as astronomy, biomedical imaging and high- energy physics. These devices are sensitive to single photons over a photon energy spectrum defined by the transmission of the optical entrance window and the photo-cathode type. Their spatial resolution ranges from a few millimeters for pad hybrid photon detectors and multi-anode photo-multiplier tubes down to a few tens of microns for pixel hybrid photon detectors and electron-bombarded charge-coupled devices. Basic technological and design aspects are assessed in this paper. (21 refs).

  2. New Schemes for Positive Real Truncation

    Directory of Open Access Journals (Sweden)

    Kari Unneland

    2007-07-01

    Full Text Available Model reduction, based on balanced truncation, of stable and of positive real systems are considered. An overview over some of the already existing techniques are given: Lyapunov balancing and stochastic balancing, which includes Riccati balancing. A novel scheme for positive real balanced truncation is then proposed, which is a combination of the already existing Lyapunov balancing and Riccati balancing. Using Riccati balancing, the solution of two Riccati equations are needed to obtain positive real reduced order systems. For the suggested method, only one Lyapunov equation and one Riccati equation are solved in order to obtain positive real reduced order systems, which is less computationally demanding. Further it is shown, that in order to get positive real reduced order systems, only one Riccati equation needs to be solved. Finally, this is used to obtain positive real frequency weighted balanced truncation.

  3. POSITION-SPECIFIC DEFICIT OF JOINT POSITION SENSE IN ANKLES WITH CHRONIC FUNCTIONAL INSTABILITY

    Directory of Open Access Journals (Sweden)

    Shigeki Yokoyama

    2008-12-01

    Full Text Available The present study was aimed to test a hypothesis that individuals with functional ankle instability (FAI underestimate the joint angle at greater plantarflexion and inversion. Seventeen males with unilateral FAI and 17 controls (males without FAI consented for participation in this IRB-approved, case-control study. Using a passive reproduction test, we assessed ankle joint position sense (JPS for test positions between 30 and -10 degrees plantarflexion with an inclement of 10 degrees with or without 20° inversion at each plantarflexion angle. The constant error (CE was defined as the value obtained by subtracting the true angle of a test position from the corresponding perceived angle. At plantarflexed and inverted test positions, the CE values were smaller in negative with greater in the FAI group than in the control group. That is, in the FAI group, the FAI group underestimated the true plantarflexion angle at combined 30° plantarflexion and 20° inversion. We conclude that the ankle with FAI underestimate the amount of plantarflexion, which increases the chance of reaching greater planterflexion and inversion than patients' intention at high risk situations of spraining such as landing

  4. Comparison in performance of sediment microbial fuel cells according to depth of embedded anode.

    Science.gov (United States)

    An, Junyeong; Kim, Bongkyu; Nam, Jonghyeon; Ng, How Yong; Chang, In Seop

    2013-01-01

    Five rigid graphite plates were embedded in evenly divided sections of sediment, ranging from 2 cm (A1) to 10 cm (A5) below the top sediment layer. The maximum power and current of the MFCs increased in depth order; however, despite the increase in the internal resistance, the power and current density of the A5 MFC were 2.2 and 3.5 times higher, respectively, than those of the A1 MFC. In addition, the anode open circuit potentials (OCPs) of the sediment microbial fuel cells (SMFCs) became more negative with sediment depth. Based on these results, it could be then concluded that as the anode-embedding depth increases, that the anode environment is thermodynamically and kinetically favorable to anodophiles or electrophiles. Therefore, the anode-embedding depth should be considered an important parameter that determines the performance of SMFCs, and we posit that the anode potential could be one indicator for selecting the anode-embedding depth. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... ENT Doctor Near You Continuous Positive Airway Pressure (CPAP) Continuous Positive Airway Pressure (CPAP) Patient Health Information ... relations staff at newsroom@entnet.org . What Is CPAP? The most common and effective nonsurgical treatment for ...

  6. 'The methodology of positive economics' does not give us the methodology of positive economics

    NARCIS (Netherlands)

    U.I. Mäki (Uskali)

    2003-01-01

    textabstractIt is argued that rather than a well defined F-Twist, Milton Friedman's 'Methodology of positive economies' offers an F-Mix: a pool of ambiguous and inconsistent ingredients that can be used for putting together a number of different methodological positions. This concerns issues such as

  7. Simultaneous and spontaneous reversal of positional nystagmus; an unusual peripheral sign of benign paroxysmal positional vertigo

    Directory of Open Access Journals (Sweden)

    Sertac Yetiser, MD

    2017-06-01

    Full Text Available Direction-changing positional nystagmus is generally thought to be of central origin. Reversal of initial positional nystagmus during maintaining the head position in patients with benign paroxysmal positional vertigo (BPPV is quite unusual and could be a sign of peripheral pathology. Vestibular reflex adaptation, simultaneous co-existence of canalolithiasis and cupulolithiasis in the same or both ears and changing in direction of debris movement have been proposed for the mechanism of this phenomenon. This can be a sign of simultaneous ampullopedal and ampulofugal flows during single head movement. This double-phase pattern of flow causing reversal of positional nystagmus could be related with the amount, location and dispersal of otolithic debris inside the membranous labyrinth. Four patients (3 lateral canal canalolithiasis and 1 posterior canal with reversing spontaneous nystagmus among 530 patients with BPPV have been identified in our clinic. They have been cured with standard re-positioning maneuvers. Endolymphatic reflux theory has been proposed as the underlying mechanism for unusual behavior of otolithic debris.

  8. A randomized controlled trial of positioning treatments in infants with positional head shape deformities.

    Science.gov (United States)

    Hutchison, B Lynne; Stewart, Alistair W; De Chalain, Tristan B; Mitchell, Edwin A

    2010-10-01

    Randomized controlled trials of treatment for deformational plagiocephaly and brachycephaly have been lacking in the literature. Infants (n = 126) presenting to a plagiocephaly clinic were randomized to either positioning strategies or to positioning plus the use of a Safe T Sleep™ positioning wrap. Head shape was measured using a digital photographic technique, and neck function was assessed. They were followed up at home 3, 6 and 12 months later. There was no difference in head shape outcomes for the two treatment groups after 12 months of follow-up, with 42% of infants having head shapes in the normal range by that time. Eighty per cent of children showed good improvement. Those that had poor improvement were more likely to have both plagiocephaly and brachycephaly and to have presented later to clinic. Most infants improved over the 12-month study period, although the use of a sleep positioning wrap did not increase the rate of improvement. © 2010 The Author(s)/Journal Compilation © 2010 Foundation Acta Paediatrica.

  9. Determination of global positioning system (GPS) receiver clock errors: impact on positioning accuracy

    International Nuclear Information System (INIS)

    Yeh, Ta-Kang; Hwang, Cheinway; Xu, Guochang; Wang, Chuan-Sheng; Lee, Chien-Chih

    2009-01-01

    Enhancing the positioning precision is the primary pursuit of global positioning system (GPS) users. To achieve this goal, most studies have focused on the relationship between GPS receiver clock errors and GPS positioning precision. This study utilizes undifferentiated phase data to calculate GPS clock errors and to compare with the frequency of cesium clock directly, to verify estimated clock errors by the method used in this paper. The frequency stability calculated from this paper (the indirect method) and measured from the National Standard Time and Frequency Laboratory (NSTFL) of Taiwan (the direct method) match to 1.5 × 10 −12 (the value from this study was smaller than that from NSTFL), suggesting that the proposed technique has reached a certain level of quality. The built-in quartz clocks in the GPS receivers yield relative frequency offsets that are 3–4 orders higher than those of rubidium clocks. The frequency stability of the quartz clocks is on average two orders worse than that of the rubidium clock. Using the rubidium clock instead of the quartz clock, the horizontal and vertical positioning accuracies were improved by 26–78% (0.6–3.6 mm) and 20–34% (1.3–3.0 mm), respectively, for a short baseline. These improvements are 7–25% (0.3–1.7 mm) and 11% (1.7 mm) for a long baseline. Our experiments show that the frequency stability of the clock, rather than relative frequency offset, is the governing factor of positioning accuracy

  10. Do lightning positive leaders really "step"?

    Science.gov (United States)

    Petersen, D.

    2015-12-01

    It has been known for some time that positive leaders exhibit impulsive charge motion and optical emissions as they extend. However, laboratory and field observations have not produced any evidence of a process analogous to the space leader mechanism of negative leader extension. Instead, observations have suggested that the positive leader tip undergoes a continuous to intermittent series of corona streamer bursts, each burst resulting in a small forward extension of the positive leader channel. Traditionally, it has been held that lightning positive leaders extend in a continuous or quasi-continuous fashion. Lately, however, many have become concerned that this position is incongruous with observations of impulsive activity during lightning positive leader extension. It is increasingly suggested that this impulsive activity is evidence that positive leaders also undergo "stepping". There are two issues that must be addressed. The first issue concerns whether or not the physical processes underlying impulsive extension in negative and positive leaders are distinct. We argue that these processes are in fact physically distinct, and offer new high-speed video evidence to support this position. The second issue regards the proper use of the term "step" as an identifier for the impulsive forward extension of a leader. Traditional use of this term has been applied only to negative leaders, due primarily to their stronger impulsive charge motions and photographic evidence of clearly discontinuous forward progression of the luminous channel. Recently, due to the increasing understanding of the distinct "space leader" process of negative leader extension, the term "step" has increasingly come to be associated with the space leader process itself. Should this emerging association, "step" = space leader attachment, be canonized? If not, then it seems reasonable to use the term "step" to describe impulsive positive leader extension. If, however, we do wish to associate the

  11. Positivity for Convective Semi-discretizations

    KAUST Repository

    Fekete, Imre; Ketcheson, David I.; Loczi, Lajos

    2017-01-01

    We propose a technique for investigating stability properties like positivity and forward invariance of an interval for method-of-lines discretizations, and apply the technique to study positivity preservation for a class of TVD semi-discretizations

  12. Detector Position Estimation for PET Scanners.

    Science.gov (United States)

    Pierce, Larry; Miyaoka, Robert; Lewellen, Tom; Alessio, Adam; Kinahan, Paul

    2012-06-11

    Physical positioning of scintillation crystal detector blocks in Positron Emission Tomography (PET) scanners is not always exact. We test a proof of concept methodology for the determination of the six degrees of freedom for detector block positioning errors by utilizing a rotating point source over stepped axial intervals. To test our method, we created computer simulations of seven Micro Crystal Element Scanner (MiCES) PET systems with randomized positioning errors. The computer simulations show that our positioning algorithm can estimate the positions of the block detectors to an average of one-seventh of the crystal pitch tangentially, and one-third of the crystal pitch axially. Virtual acquisitions of a point source grid and a distributed phantom show that our algorithm improves both the quantitative and qualitative accuracy of the reconstructed objects. We believe this estimation algorithm is a practical and accurate method for determining the spatial positions of scintillation detector blocks.

  13. Detector position estimation for PET scanners

    International Nuclear Information System (INIS)

    Pierce, Larry; Miyaoka, Robert; Lewellen, Tom; Alessio, Adam; Kinahan, Paul

    2012-01-01

    Physical positioning of scintillation crystal detector blocks in Positron Emission Tomography (PET) scanners is not always exact. We test a proof of concept methodology for the determination of the six degrees of freedom for detector block positioning errors by utilizing a rotating point source over stepped axial intervals. To test our method, we created computer simulations of seven Micro Crystal Element Scanner (MiCES) PET systems with randomized positioning errors. The computer simulations show that our positioning algorithm can estimate the positions of the block detectors to an average of one-seventh of the crystal pitch tangentially, and one-third of the crystal pitch axially. Virtual acquisitions of a point source grid and a distributed phantom show that our algorithm improves both the quantitative and qualitative accuracy of the reconstructed objects. We believe this estimation algorithm is a practical and accurate method for determining the spatial positions of scintillation detector blocks.

  14. Fourier-positivity constraints on QCD dipole models

    Directory of Open Access Journals (Sweden)

    Bertrand G. Giraud

    2016-09-01

    Full Text Available Fourier-positivity (F-positivity, i.e. the mathematical property that a function has a positive Fourier transform, can be used as a constraint on the parametrization of QCD dipole-target cross-sections or Wilson line correlators in transverse position space r. They are Bessel transforms of positive transverse momentum dependent gluon distributions. Using mathematical F-positivity constraints on the limit r→0 behavior of the dipole amplitudes, we identify the common origin of the violation of F-positivity for various, however phenomenologically convenient, dipole models. It is due to the behavior r2+ϵ, ϵ>0 softer, even slightly, than color transparency. F-positivity seems thus to conflict with the present dipole formalism when it includes a QCD running coupling constant α(r.

  15. Uncharged positive electrode composition

    Science.gov (United States)

    Kaun, Thomas D.; Vissers, Donald R.; Shimotake, Hiroshi

    1977-03-08

    An uncharged positive-electrode composition contains particulate lithium sulfide, another alkali metal or alkaline earth metal compound other than sulfide, e.g., lithium carbide, and a transition metal powder. The composition along with a binder, such as electrolytic salt or a thermosetting resin is applied onto an electrically conductive substrate to form a plaque. The plaque is assembled as a positive electrode within an electrochemical cell opposite to a negative electrode containing a material such as aluminum or silicon for alloying with lithium. During charging, lithium alloy is formed within the negative electrode and transition metal sulfide such as iron sulfide is produced within the positive electrode. Excess negative electrode capacity over that from the transition metal sulfide is provided due to the electrochemical reaction of the other than sulfide alkali metal or alkaline earth metal compound.

  16. Commentary: Positive Youth Development Goes Mainstream.

    Science.gov (United States)

    Moore, Kristin A

    2017-07-01

    Evidence has accumulated that confirms the success of a positive youth development (PYD) approach. Importantly, a positive development approach is just that-an approach. It is not a particular program or curriculum but a set of practices designed to achieve one or more positive outcomes. As such, PYD practices can be added onto other programs to make positive outcomes more likely. For example, a tutoring program can work hard to hire and train staff to work with students in a trusting, respectful relationship. Camp counselors can be encouraged to build rapport and positive bonds among the campers. © 2017 The Author. Child Development © 2017 Society for Research in Child Development, Inc.

  17. Comparison of bladder neck position in nulliparous and parous women using MR images in the sitting position

    International Nuclear Information System (INIS)

    Masaki, Kiyoko; Okayama, Hisayo; Tuchikawa, Sachi; Saito, Yoshino; Endo, Yoshihiro; Morikawa, Shigehiro; Ninomiya, Sanae; Saito, Izumi; Hiraiwa, Yasuyuki

    2011-01-01

    The purpose of this study was to investigate the influence of childbirth on pelvic floor relaxation in females using the bladder neck position. The position of bladder neck was examined in 17 nulligravid (19-24 years of age) and 55 parous women (35-54) using MR images in the sitting position. The position of bladder neck from pubococcygeal line was 13.4 mm (mean) in nulligravid women, and 8.5 mm in parous women (p<0.05). The bladder neck position in parous women was significantly lower than that in nulligravid women. Therefore, it was clearly shown that childbirth causes the pelvic floor relaxation. (author)

  18. The effect of an auxiliary discharge on anode sheath potentials in a transverse discharge

    International Nuclear Information System (INIS)

    Foster, J.E.; Gallimore, A.D.

    1997-01-01

    A novel scheme that employs the use of an auxiliary discharge has been shown to reduce markedly anode sheath potentials in a transverse discharge. An 8.8 A low-pressure argon discharge in the presence of a transverse magnetic field was used as the plasma source in this study. In such discharges, the transverse flux that is collected by the anode is severely limited due to marked reductions in the transverse diffusion coefficient. Findings of this study indicate that the local electron number density and the transverse flux increase when the auxiliary discharge is operated. Changes in these parameters are reflected in the measured anode sheath voltage. Anode sheath potentials, estimated by using Langmuir probes, were shown to be reduced by over 33% when the auxiliary discharge is operated. These reductions in anode sheath potentials translated into significant reductions in anode power flux as measured using water calorimeter techniques. The reductions in anode power flux also correlate well with changes in the electron transverse flux. Finally, techniques implementing these positive effects in real plasma accelerators are discussed. copyright 1997 American Institute of Physics

  19. Social position and health in old age. The relevance of different indicators of social position

    DEFF Research Database (Denmark)

    Avlund, Kirsten; Holstein, Bjørn Evald; Osler, Merete

    2002-01-01

    Social medicine, social position, chronic diseases, material wealth, income, tenure, oral health, functional ability, well-being, mobility......Social medicine, social position, chronic diseases, material wealth, income, tenure, oral health, functional ability, well-being, mobility...

  20. Cadastral Database Positional Accuracy Improvement

    Science.gov (United States)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  1. Parent Personality and Positive Parenting as Predictors of Positive Adolescent Personality Development over Time

    Science.gov (United States)

    Schofield, Thomas J.; Conger, Rand D.; Donnellan, M. Brent; Jochem, Rachel; Widaman, Keith F.; Conger, Katherine J.

    2012-01-01

    We investigated the degree to which parent positive personality characteristics in terms of conscientiousness, agreeableness, and emotional stability predict similar adolescent personality traits over time, as well as the role played by positive parenting in this process. Mothers and fathers of 451 White adolescents (52% female, mean age = 13.59…

  2. A Positive Deviance Approach to Early Childhood Obesity: Cross-Sectional Characterization of Positive Outliers

    OpenAIRE

    Foster, Byron Alexander; Farragher, Jill; Parker, Paige; Hale, Daniel E.

    2015-01-01

    Objective: Positive deviance methodology has been applied in the developing world to address childhood malnutrition and has potential for application to childhood obesity in the United States. We hypothesized that among children at high-risk for obesity, evaluating normal weight children will enable identification of positive outlier behaviors and practices.

  3. Ad-Coop Positioning System (ACPS)

    DEFF Research Database (Denmark)

    Frattasi, Simone; Monti, Marco

    2008-01-01

    In this paper, we propose an innovative solution for positioning determination in 4G wireless networks by introducing the Ad-Coop Positioning System (ACPS). The ACPS is supported by a hybrid cellular ad-hoc architecture, where the cellular network has a centralized control over the ad-hoc connect......In this paper, we propose an innovative solution for positioning determination in 4G wireless networks by introducing the Ad-Coop Positioning System (ACPS). The ACPS is supported by a hybrid cellular ad-hoc architecture, where the cellular network has a centralized control over the ad...... method for the ACPS, which appropriately combines and weights the long- and short-range location information in a non-linear least square (NLLS) minimization procedure. The numerical results shown in the paper demonstrate that the ACPS enhances the location estimation accuracy with respect...

  4. 28 CFR 345.20 - Position classification.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Position classification. 345.20 Section... INDUSTRIES (FPI) INMATE WORK PROGRAMS Position Classification § 345.20 Position classification. (a) Inmate... the objectives and principles of pay classification as a part of the routine orientation of new FPI...

  5. The NASA competitive placement plan for positions GS-15 and below (including trades and labor positions)

    Science.gov (United States)

    1993-01-01

    This plan provides the framework for selection based on merit from among the best qualified candidates available. Selections will be made without regard to political, religious, or labor organization affiliation or nonaffiliation, marital status, race, color, sex, national origin, nondisqualifying disability, or age. This plan does not guarantee promotion but rather ensures that all qualified available candidates receive fair and equitable consideration for positions filled under these competitive procedures. Announcing a vacancy under this plan is only one method of locating applicants for a position and can be used in conjunction with other methods. Subject to applicable law and regulation, selection of an individual to fill a position is the decision of management, as is the decision as to the method(s) to be used in identifying candidates. This plan is applicable to all NASA Installations. It covers all positions in the competitive service at (and below) the GS/GM-15 level (including all trades and labor positions), except positions in the Office of the Inspector General. The requirements herein are not intended to, nor should they be construed to limit in any way, the independent personnel authority of the Inspector General under the Inspector General Act, as Amended.

  6. Anode-cathode power distribution systems and methods of using the same for electrochemical reduction

    Science.gov (United States)

    Koehl, Eugene R; Barnes, Laurel A; Wiedmeyer, Stanley G; Williamson, Mark A; Willit, James L

    2014-01-28

    Power distribution systems are useable in electrolytic reduction systems and include several cathode and anode assembly electrical contacts that permit flexible modular assembly numbers and placement in standardized connection configurations. Electrical contacts may be arranged at any position where assembly contact is desired. Electrical power may be provided via power cables attached to seating assemblies of the electrical contacts. Cathode and anode assembly electrical contacts may provide electrical power at any desired levels. Pairs of anode and cathode assembly electrical contacts may provide equal and opposite electrical power; different cathode assembly electrical contacts may provide different levels of electrical power to a same or different modular cathode assembly. Electrical systems may be used with an electrolyte container into which the modular cathode and anode assemblies extend and are supported above, with the modular cathode and anode assemblies mechanically and electrically connecting to the respective contacts in power distribution systems.

  7. tDCS over the left prefrontal cortex enhances cognitive control for positive affective stimuli.

    Science.gov (United States)

    Vanderhasselt, Marie-Anne; De Raedt, Rudi; Brunoni, Andre R; Campanhã, Camila; Baeken, Chris; Remue, Jonathan; Boggio, Paulo S

    2013-01-01

    Transcranial Direct Current Stimulation (tDCS) is a neuromodulation technique with promising results for enhancing cognitive information processes. So far, however, research has mainly focused on the effects of tDCS on cognitive control operations for non-emotional material. Therefore, our aim was to investigate the effects on cognitive control considering negative versus positive material. For this sham-controlled, within-subjects study, we selected a homogeneous sample of twenty-five healthy participants. By using behavioral measures and event related potentials (ERP) as indexes, we aimed to investigate whether a single session of anodal tDCS of the left dorsolateral prefrontal cortex (DLPFC) would have specific effects in enhancing cognitive control for positive and negative valenced stimuli. After tDCS over the left DLPFC (and not sham control stimulation), we observed more negative N450 amplitudes along with faster reaction times when inhibiting a habitual response to happy compared to sad facial expressions. Gender did not influence the effects of tDCS on cognitive control for emotional information. In line with the Valence Theory of side-lateralized activity, this stimulation protocol might have led to a left dominant (relative to right) prefrontal cortical activity, resulting in augmented cognitive control specifically for positive relative to negative stimuli. To verify that tDCS induces effects that are in line with all aspects of the well known Valence Theory, future research should investigate the effects of tDCS over the left vs. right DLPFC on cognitive control for emotional information.

  8. 30 CFR 56.7052 - Drilling positions.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drilling positions. 56.7052 Section 56.7052... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7052 Drilling positions. Persons shall not drill from— (a) Positions which hinder...

  9. Positioning intermediary organisations in innovation

    NARCIS (Netherlands)

    Lente, van H.; Boon, W.P.C.; Klerkx, L.W.A.

    2010-01-01

    Abstract: Intermediary organisations are important in innovation systems and their contributions seem to increase. The central ambition of this paper is to understand and analyse the position of intermediaries within innovation networks. We use so-called positioning theory, where roles are outcomes

  10. Sustained attention to objects' motion sharpens position representations: Attention to changing position and attention to motion are distinct.

    Science.gov (United States)

    Howard, Christina J; Rollings, Victoria; Hardie, Amy

    2017-06-01

    In tasks where people monitor moving objects, such the multiple object tracking task (MOT), observers attempt to keep track of targets as they move amongst distracters. The literature is mixed as to whether observers make use of motion information to facilitate performance. We sought to address this by two means: first by superimposing arrows on objects which varied in their informativeness about motion direction and second by asking observers to attend to motion direction. Using a position monitoring task, we calculated mean error magnitudes as a measure of the precision with which target positions are represented. We also calculated perceptual lags versus extrapolated reports, which are the times at which positions of targets best match position reports. We find that the presence of motion information in the form of superimposed arrows made no difference to position report precision nor perceptual lag. However, when we explicitly instructed observers to attend to motion, we saw facilitatory effects on position reports and in some cases reports that best matched extrapolated rather than lagging positions for small set sizes. The results indicate that attention to changing positions does not automatically recruit attention to motion, showing a dissociation between sustained attention to changing positions and attention to motion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Positions in doctors' questions during psychiatric interviews.

    Science.gov (United States)

    Ziółkowska, Justyna

    2009-11-01

    In this article I apply the concept of positioning to the analysis of 15 initial psychiatric interviews. I argue that through their questions the psychiatrists-in-training impose positions requiring the patients to gaze at themselves and their actual problems from particular perspectives. I point to three such positions: (a) the position of the observing assessor, from which it is expected that the patients will make a detached assessment of themselves or their problems, (b) the position of the informing witness, which requires the patients only to verify the information about themselves, and (c) the marginal one, the position of the experiencing narrator, from which talk about experiences and problems is expected. I explore the roots and consequences of the positions, with particular attention toward objectivization of the patients' experiences in the dominant witness and assessor positions. I conclude with a discussion about the medical model in psychiatry.

  12. A novel method for estimating the initial rotor position of PM motors without the position sensor

    International Nuclear Information System (INIS)

    Rostami, Alireza; Asaei, Behzad

    2009-01-01

    Permanent magnet (PM) motors have been used widely in the industrial applications. However, a need of the position sensor is a drawback of their control system. The sensorless methods using the back-EMF (electromotive force) cannot detect the rotor position at a standstill; recently, a few methods proposed to detect the initial rotor position, but they have high estimation error which reduces starting torque of the motor. Therefore, in this paper, a novel method to detect the initial rotor position of the PM motors is proposed, first, by using a space vector model, response of the stator current space vector to the saturation of the stator core is analyzed; then a novel method based on the saturation effect is presented that estimates the initial rotor position and the maximum estimation error is less than 3.8 deg. Simulation results confirm this method is effective and precise, and variation of the motor parameters does not affect its precision.

  13. A novel method for estimating the initial rotor position of PM motors without the position sensor

    Energy Technology Data Exchange (ETDEWEB)

    Rostami, Alireza; Asaei, Behzad [School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, Tehran (Iran)

    2009-08-15

    Permanent magnet (PM) motors have been used widely in the industrial applications. However, a need of the position sensor is a drawback of their control system. The sensorless methods using the back-EMF (electromotive force) cannot detect the rotor position at a standstill; recently, a few methods proposed to detect the initial rotor position, but they have high estimation error which reduces starting torque of the motor. Therefore, in this paper, a novel method to detect the initial rotor position of the PM motors is proposed, first, by using a space vector model, response of the stator current space vector to the saturation of the stator core is analyzed; then a novel method based on the saturation effect is presented that estimates the initial rotor position and the maximum estimation error is less than 3.8. Simulation results confirm this method is effective and precise, and variation of the motor parameters does not affect its precision. (author)

  14. Promoting positive parenting: an annotated bibliography.

    Science.gov (United States)

    Ahmann, Elizabeth

    2002-01-01

    Positive parenting is built on respect for children and helps develop self-esteem, inner discipline, self-confidence, responsibility, and resourcefulness. Positive parenting is also good for parents: parents feel good about parenting well. It builds a sense of dignity. Positive parenting can be learned. Understanding normal development is a first step, so that parents can distinguish common behaviors in a stage of development from "problems." Central to positive parenting is developing thoughtful approaches to child guidance that can be used in place of anger, manipulation, punishment, and rewards. Support for developing creative and loving approaches to meet special parenting challenges, such as temperament, disabilities, separation and loss, and adoption, is sometimes necessary as well. This annotated bibliography offers resources to professionals helping parents and to parents wishing to develop positive parenting skills.

  15. Intrapartum Ultrasound Assessment of Fetal Spine Position

    Directory of Open Access Journals (Sweden)

    Salvatore Gizzo

    2014-01-01

    Full Text Available We investigated the role of foetal spine position in the first and second labour stages to determine the probability of OPP detection at birth and the related obstetrical implications. We conducted an observational-longitudinal cohort study on uncomplicated cephalic single foetus pregnant women at term. We evaluated the accuracy of ultrasound in predicting occiput position at birth, influence of fetal spine in occiput position during labour, labour trend, analgesia request, type of delivery, and indication to CS. The accuracy of the foetal spinal position to predict the occiput position at birth was high at the first labour stage. At the second labour stage, CS (40.3% and operative vaginal deliveries (23.9% occurred more frequently in OPP than in occiput anterior position (7% and 15.2%, resp., especially in cases of the posterior spine. In concordant posterior positions labour length was greater than other ones, and analgesia request rate was 64.1% versus 14.7% for all the others. The assessment of spinal position could be useful in obstetrical management and counselling, both before and during labour. The detection of spinal position, more than OPP, is predictive of successful delivery. In concordant posterior positions, the labour length, analgesia request, operative delivery, and caesarean section rate are higher than in the other combination.

  16. Positioning Theory and Higher Education Research

    DEFF Research Database (Denmark)

    Christensen, Mette Krogh; Musaeus, Peter; Petersen, Eva Bendix

    The aim of this symposium is to connect scholars who use positioning theory in their research on very diverse issues in higher education and to open up the analytic to others who may be interested in taking it up. Positioning theory is a social constructionist approach and it emerged in the 1980s...... available. After this introduction, four paper presentations will follow (see abstracts below), and the session will conclude with a whole-group discussion of the potentials and pitfalls of the approach.......The aim of this symposium is to connect scholars who use positioning theory in their research on very diverse issues in higher education and to open up the analytic to others who may be interested in taking it up. Positioning theory is a social constructionist approach and it emerged in the 1980s...... in gender studies and social psychology. It is concerned with theorising and analysing how people position themselves and others, and the personal, relational, cultural, moral, political, and institutional effects hereof. Positioning theory is most commonly used in studies of the discursive constitution...

  17. Resources that promote positive youth development

    Directory of Open Access Journals (Sweden)

    Martha Frías Armenta

    2016-12-01

    Full Text Available Adolescence is a crucial developmental phase that shapes people´s futures. Positive psychology investigates the variables that promote the optimal development of human beings. It recognizes that all children and adolescents have strengths that will develop once these strengths match the resources needed to achieve this in the various settings in which they live. The aim of this study was to analyze from a multidisciplinary perspective (e.g. psychological, sociological, and economic the effect of resources that promote positive youth development. The sample consisted of 200 middle school students (15 to 19 years. EQS statistical software was used to analyse a structural equation model in which the study variables comprised 4 factors: one for each resource (economic, psychological, sociological, and one for positive youth development. The results showed a direct association between psychological and social resources and positive development, and between social resources and psychological assets. However, no association was found between economic resources and positive youth development. These results suggest that the main influences on positive youth development are psychological and social resources.

  18. Positive Predictive Value of True Bacteremia according to the Number of Positive Culture Sets in Adult Patients.

    Science.gov (United States)

    Kitaura, Tsuyoshi; Chikumi, Hiroki; Fujiwara, Hiromitsu; Okada, Kensaku; Hayabuchi, Tatsuya; Nakamoto, Masaki; Takata, Miyako; Yamasaki, Akira; Igishi, Tadashi; Burioka, Naoto; Shimizu, Eiji

    2014-12-01

    Performing multiple blood culture sets simultaneously is a standard blood culture methodology, although it is often difficult to distinguish true bacteremia from contamination when only one of several blood culture sets is positive. This study clarified the relationship between the number of positive blood culture sets and clinical significance in patients with positive blood culture. Patients aged 18 years and over with at least 1 positive blood culture were enrolled. Positive blood culture episodes were categorized from clinical records as true bacteremia, contamination, or unknown clinical significance. The associations among episodes of true bacteremia, isolated bacteria, the number of positive blood culture sets from among the performed sets, and the clinical background of patients were analyzed. Among a total of 407 episodes, 262, 67 and 78 were true bacteremia, contamination and unknown clinical significance, respectively. The positive predictive values (PPVs) of 1 out of 1, 1 out of 2 and 2 out of 2 positive sets in cases of Staphylococcus aureus, were 81.3%, 50% and 100% respectively; those in cases of coagulase-negative Staphylococci were 20.5%, 10.8% and 63.5%, respectively. Almost all cases of Escherichia coli, Pseudomonas aeruginosa, Klebsiella species and Candida species were true bacteremia. The probability of true bacteremia was strongly associated with recent surgery in multivariate analysis (P sets from among the performed sets varies by microorganism. Therefore, PPVs calculated using this method may help physicians distinguish true bacteremia from contamination.

  19. Convergence Time and Positioning Accuracy Comparison between BDS and GPS Precise Point Positioning

    Directory of Open Access Journals (Sweden)

    ZHANG Xiaohong

    2015-03-01

    Full Text Available BDS/GPS data from MGEX were processed by TriP 2.0 software developed at Wuhan University. Both static and kinematic float PPP are tested by adopting precise satellite orbits and clocks provided by Research Center of GNSS, Wuhan University. The results show that the convergence time of BDS static PPP is about 80min while kinematic PPP is about 100min. For 3h observations, static positioning accuracy of 5 cm and kinematic positioning accuracy of 8 cm in horizontal, about 12 cm in vertical can be achieved. Similar to GPS PPP, precision in east component is worse than north. At present, BDS PPP needs longer convergence time than GPS PPP to reach an absolute positioning accuracy of cm~dm due to the lack of global tracking stations and the limited accuracy of orbit and clock products.

  20. In-plane user positioning indoors

    NARCIS (Netherlands)

    Jovanovic, N.; Özçelebi, T.; Lukkien, J.J.; Skoric, B.; Ignatenko, T.

    2014-01-01

    Indoor positioning is a service required by many smart environment applications for various purposes, such as activity classification, indoor navigation and context awareness. In this paper, we present a novel approach to the user positioning problem based on in-plane detection enabled by a set of

  1. 21 CFR 868.6820 - Patient position support.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6820 Patient position support. (a) Identification. A patient position support is a device intended to maintain the position of an anesthetized... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient position support. 868.6820 Section 868...

  2. Navigation studies based on the ubiquitous positioning technologies

    Science.gov (United States)

    Ye, Lei; Mi, Weijie; Wang, Defeng

    2007-11-01

    This paper summarized the nowadays positioning technologies, such as absolute positioning methods and relative positioning methods, indoor positioning and outdoor positioning, active positioning and passive positioning. Global Navigation Satellite System (GNSS) technologies were introduced as the omnipresent out-door positioning technologies, including GPS, GLONASS, Galileo and BD-1/2. After analysis of the shortcomings of GNSS, indoor positioning technologies were discussed and compared, including A-GPS, Cellular network, Infrared, Electromagnetism, Computer Vision Cognition, Embedded Pressure Sensor, Ultrasonic, RFID (Radio Frequency IDentification), Bluetooth, WLAN etc.. Then the concept and characteristics of Ubiquitous Positioning was proposed. After the ubiquitous positioning technologies contrast and selection followed by system engineering methodology, a navigation system model based on Incorporate Indoor-Outdoor Positioning Solution was proposed. And this model was simulated in the Galileo Demonstration for World Expo Shanghai project. In the conclusion, the prospects of ubiquitous positioning based navigation were shown, especially to satisfy the public location information acquiring requirement.

  3. Focused-laser interferometric position sensor

    International Nuclear Information System (INIS)

    Friedman, Stephen J.; Barwick, Brett; Batelaan, Herman

    2005-01-01

    We describe a simple method to measure the position shifts of an object with a range of tens of micrometers using a focused-laser (FL) interferometric position sensor. In this article we examine the effects of mechanical vibration on FL and Michelson interferometers. We tested both interferometers using vibration amplitudes ranging from 0 to 20 μm. Our FL interferometer has a resolution much better than the diffraction grating periodicities of 10 and 14 μm used in our experiments. A FL interferometer provides improved mechanical stability at the expense of spatial resolution. Our experimental results show that Michelson interferometers cannot be used when the vibration amplitude is more than an optical wavelength. The main purpose of this article is to demonstrate that a focused-laser interferometric position sensor can be used to measure the position shifts of an object on a less sensitive, micrometer scale when the vibration amplitude is too large to use a Michelson interferometer

  4. Being Positive. Approaching Career Design from the Perspective of Positive Psychology

    Directory of Open Access Journals (Sweden)

    Małgorzata Klimka

    2015-09-01

    Full Text Available Constructing a career path based upon positive personal potential and positive individual resources is a significant factor for professional development of employees and their success on today’s labour market. A satisfying career, an inherent element of personal well-being and good life, is linked with an ability to explore and reinforce signature strengths. In order to effectively design programmes which could support young people who are preparing to enter a job market, it is essential to acquire knowledge about values and character strengths and their perceptions among young people living in Poland and abroad. The article presents comparative analysis of signature strengths perceptions among young people in different cultures and discusses the significance of the most striking differences.

  5. Serial position learning in honeybees.

    Directory of Open Access Journals (Sweden)

    Randolf Menzel

    Full Text Available Learning of stimulus sequences is considered as a characteristic feature of episodic memory since it contains not only a particular item but also the experience of preceding and following events. In sensorimotor tasks resembling navigational performance, the serial order of objects is intimately connected with spatial order. Mammals and birds develop episodic(-like memory in serial spatio-temporal tasks, and the honeybee learns spatio-temporal order when navigating between the nest and a food source. Here I examine the structure of the bees' memory for a combined spatio-temporal task. I ask whether discrimination and generalization are based solely on simple forms of stimulus-reward learning or whether they require sequential configurations. Animals were trained to fly either left or right in a continuous T-maze. The correct choice was signaled by the sequence of colors (blue, yellow at four positions in the access arm. If only one of the possible 4 signals is shown (either blue or yellow, the rank order of position salience is 1, 2 and 3 (numbered from T-junction. No learning is found if the signal appears at position 4. If two signals are shown, differences at positions 1 and 2 are learned best, those at position 3 at a low level, and those at position 4 not at all. If three or more signals are shown these results are corroborated. This salience rank order again appeared in transfer tests, but additional configural phenomena emerged. Most of the results can be explained with a simple model based on the assumption that the four positions are equipped with different salience scores and that these add up independently. However, deviations from the model are interpreted by assuming stimulus configuration of sequential patterns. It is concluded that, under the conditions chosen, bees rely most strongly on memories developed during simple forms of associative reward learning, but memories of configural serial patterns contribute, too.

  6. Inductive Non-Contact Position Sensor

    Science.gov (United States)

    Youngquist, Robert; Garcia, Alyssa; Simmons, Stephen

    2010-01-01

    Optical hardware has been developed to measure the depth of defects in the Space Shuttle Orbiter's windows. In this hardware, a mirror is translated such that its position corresponds to the defect's depth, so the depth measurement problem is transferred to a mirror-position measurement problem. This is preferable because the mirror is internal to the optical system and thus accessible. Based on requirements supplied by the window inspectors, the depth of the defects needs to be measured over a range of 200 microns with a resolution of about 100 nm and an accuracy of about 400 nm. These same requirements then apply to measuring the position of the mirror, and in addition, since this is a scanning system, a response time of about 10 ms is needed. A market search was conducted and no sensor that met these requirements that also fit into the available housing volume (less than one cubic inch) was found, so a novel sensor configuration was constructed to meet the requirements. This new sensor generates a nearly linearly varying magnetic field over a small region of space, which can easily be sampled, resulting in a voltage proportional to position. Experiments were done with a range of inductor values, drive voltages, drive frequencies, and inductor shapes. A rough mathematical model was developed for the device that, in most aspects, describes how it operates and what electrical parameters should be chosen for best performance. The final configuration met all the requirements, yielding a small rugged sensor that was easy to use and had nanometer resolution over more than the 200-micron range required. The inductive position sensor is a compact device (potentially as small as 2 cubic centimeters), which offers nanometer-position resolution over a demonstrated range of nearly 1 mm. One of its advantages is the simplicity of its electrical design. Also, the sensor resolution is nearly uniform across its operational range, which is in contrast to eddy current and

  7. Emotional Effects of Positive Forms of Communication

    Directory of Open Access Journals (Sweden)

    Светлана Валентиновна Ионова

    2015-12-01

    Full Text Available The article discusses the problem of emotional significance of a positive form of speech. Based on the methodology of emotions linguistics, linguoecology, communicative linguistics and the methods of description, comparison and discourse analysis, the author distinguishes some types of speech situations that demonstrate visible differences between positive expression of emotions and their content and the pragmatic effect. The difference between the notions of “positive communication” and “positive form of communication” is demonstrated. Special attention is given to the following types of positive emotional communication: tolerant emotional communication, emotional emphasis, emotional neglect, and emotional tabooing. The utterances in situations of real and textual communication demonstrate negative effects of statements expressed in a positive form and identify the specifics of positive forms of emotional communication in comparison with rational communication.

  8. POSITIVE LEADERSHIP MODELS: THEORETICAL FRAMEWORK AND RESEARCH

    Directory of Open Access Journals (Sweden)

    Javier Blanch, Francisco Gil

    2016-09-01

    Full Text Available The objective of this article is twofold; firstly, we establish the theoretical boundaries of positive leadership and the reasons for its emergence. It is related to the new paradigm of positive psychology that has recently been shaping the scope of organizational knowledge. This conceptual framework has triggered the development of the various forms of positive leadership (i.e. transformational, servant, spiritual, authentic, and positive. Although the construct does not seem univocally defined, these different types of leadership overlap and share a significant affinity. Secondly, we review the empirical evidence that shows the impact of positive leadership in organizations and we highlight the positive relationship between these forms of leadership and key positive organizational variables. Lastly, we analyse future research areas in order to further develop this concept.

  9. Information Geometry of Positive Measures and Positive-Definite Matrices: Decomposable Dually Flat Structure

    Directory of Open Access Journals (Sweden)

    Shun-ichi Amari

    2014-04-01

    Full Text Available Information geometry studies the dually flat structure of a manifold, highlighted by the generalized Pythagorean theorem. The present paper studies a class of Bregman divergences called the (ρ,τ-divergence. A (ρ,τ -divergence generates a dually flat structure in the manifold of positive measures, as well as in the manifold of positive-definite matrices. The class is composed of decomposable divergences, which are written as a sum of componentwise divergences. Conversely, a decomposable dually flat divergence is shown to be a (ρ,τ -divergence. A (ρ,τ -divergence is determined from two monotone scalar functions, ρ and τ. The class includes the KL-divergence, α-, β- and (α, β-divergences as special cases. The transformation between an affine parameter and its dual is easily calculated in the case of a decomposable divergence. Therefore, such a divergence is useful for obtaining the center for a cluster of points, which will be applied to classification and information retrieval in vision. For the manifold of positive-definite matrices, in addition to the dually flatness and decomposability, we require the invariance under linear transformations, in particular under orthogonal transformations. This opens a way to define a new class of divergences, called the (ρ,τ -structure in the manifold of positive-definite matrices.

  10. Body position and late postoperative nocturnal hypoxaemia

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Stausholm, K; Edvardsen, L

    1997-01-01

    Thirteen patients were monitored for nocturnal body position (supine vs. side) and arterial oxygen saturation pre-operatively and on the second postoperative night after major abdominal surgery. The number of positional changes were significantly decreased after operation (p ... position than on the side (p movements....... towards more time spent in the supine position (p = 0.1). Individual mean arterial oxygen saturation decreased postoperatively (p positions (p = 0.9). Pre-operatively, episodic desaturations were significantly more frequent in the supine...

  11. Indoor Positioning System using Bluetooth

    OpenAIRE

    Sahil Puri

    2015-01-01

    This Paper on Bluetooth Indoor Positioning System is the intersection of Bluetooth Technology and Indoor Positioning Systems. Almost every smartphone today is Bluetooth enabled, making the use of the technology more flexible. We aim at using the RSSI value of Bluetooth signals to track the location of a device.

  12. Positive Parenting and Challenging Children

    Science.gov (United States)

    Knoll, Melissa

    2007-01-01

    Positive parenting focuses on developing proactive ways to teach and reinforce desirable behaviors, as opposed to focusing on reacting to and attempting to decrease negative behaviors. Dr. Sheldon Braaten, Executive Director of Behavioral Institute for Children and Adolescents, offers some keys for setting up and using a positive reinforcement…

  13. Positioning of aquatic animals based on time-of-arrival and random walk models using YAPS (Yet Another Positioning Solver)

    DEFF Research Database (Denmark)

    Baktoft, Henrik; Gjelland, Karl Øystein; Økland, Finn

    2017-01-01

    Aquatic positional telemetry offers vast opportunities to study in vivo behaviour of wild animals, but there is room for improvement in the data quality provided by current procedures for estimating positions. Here we present a novel positioning method called YAPS (Yet Another Positioning Solver...

  14. Position Statement on Active Outdoor Play

    Science.gov (United States)

    Tremblay, Mark S.; Gray, Casey; Babcock, Shawna; Barnes, Joel; Costas Bradstreet, Christa; Carr, Dawn; Chabot, Guylaine; Choquette, Louise; Chorney, David; Collyer, Cam; Herrington, Susan; Janson, Katherine; Janssen, Ian; Larouche, Richard; Pickett, William; Power, Marlene; Sandseter, Ellen Beate Hansen; Simon, Brenda; Brussoni, Mariana

    2015-01-01

    A diverse, cross-sectorial group of partners, stakeholders and researchers, collaborated to develop an evidence-informed Position Statement on active outdoor play for children aged 3–12 years. The Position Statement was created in response to practitioner, academic, legal, insurance and public debate, dialogue and disagreement on the relative benefits and harms of active (including risky) outdoor play. The Position Statement development process was informed by two systematic reviews, a critical appraisal of the current literature and existing position statements, engagement of research experts (N = 9) and cross-sectorial individuals/organizations (N = 17), and an extensive stakeholder consultation process (N = 1908). More than 95% of the stakeholders consulted strongly agreed or somewhat agreed with the Position Statement; 14/17 participating individuals/organizations endorsed it; and over 1000 additional individuals and organizations requested their name be listed as a supporter. The final Position Statement on Active Outdoor Play states: “Access to active play in nature and outdoors—with its risks— is essential for healthy child development. We recommend increasing children’s opportunities for self-directed play outdoors in all settings—at home, at school, in child care, the community and nature.” The full Position Statement provides context for the statement, evidence supporting it, and a series of recommendations to increase active outdoor play opportunities to promote healthy child development. PMID:26062040

  15. Position Statement on Active Outdoor Play.

    Science.gov (United States)

    Tremblay, Mark S; Gray, Casey; Babcock, Shawna; Barnes, Joel; Bradstreet, Christa Costas; Carr, Dawn; Chabot, Guylaine; Choquette, Louise; Chorney, David; Collyer, Cam; Herrington, Susan; Janson, Katherine; Janssen, Ian; Larouche, Richard; Pickett, William; Power, Marlene; Sandseter, Ellen Beate Hansen; Simon, Brenda; Brussoni, Mariana

    2015-06-08

    A diverse, cross-sectorial group of partners, stakeholders and researchers, collaborated to develop an evidence-informed Position Statement on active outdoor play for children aged 3-12 years. The Position Statement was created in response to practitioner, academic, legal, insurance and public debate, dialogue and disagreement on the relative benefits and harms of active (including risky) outdoor play. The Position Statement development process was informed by two systematic reviews, a critical appraisal of the current literature and existing position statements, engagement of research experts (N=9) and cross-sectorial individuals/organizations (N=17), and an extensive stakeholder consultation process (N=1908). More than 95% of the stakeholders consulted strongly agreed or somewhat agreed with the Position Statement; 14/17 participating individuals/organizations endorsed it; and over 1000 additional individuals and organizations requested their name be listed as a supporter. The final Position Statement on Active Outdoor Play states: "Access to active play in nature and outdoors--with its risks--is essential for healthy child development. We recommend increasing children's opportunities for self-directed play outdoors in all settings--at home, at school, in child care, the community and nature." The full Position Statement provides context for the statement, evidence supporting it, and a series of recommendations to increase active outdoor play opportunities to promote healthy child development.

  16. Position Statement on Active Outdoor Play

    Directory of Open Access Journals (Sweden)

    Mark S. Tremblay

    2015-06-01

    Full Text Available A diverse, cross-sectorial group of partners, stakeholders and researchers, collaborated to develop an evidence-informed Position Statement on active outdoor play for children aged 3–12 years. The Position Statement was created in response to practitioner, academic, legal, insurance and public debate, dialogue and disagreement on the relative benefits and harms of active (including risky outdoor play. The Position Statement development process was informed by two systematic reviews, a critical appraisal of the current literature and existing position statements, engagement of research experts (N = 9 and cross-sectorial individuals/organizations (N = 17, and an extensive stakeholder consultation process (N = 1908. More than 95% of the stakeholders consulted strongly agreed or somewhat agreed with the Position Statement; 14/17 participating individuals/organizations endorsed it; and over 1000 additional individuals and organizations requested their name be listed as a supporter. The final Position Statement on Active Outdoor Play states: “Access to active play in nature and outdoors—with its risks— is essential for healthy child development. We recommend increasing children’s opportunities for self-directed play outdoors in all settings—at home, at school, in child care, the community and nature.” The full Position Statement provides context for the statement, evidence supporting it, and a series of recommendations to increase active outdoor play opportunities to promote healthy child development.

  17. On the positivity of Riemann–Stieltjes integrals

    DEFF Research Database (Denmark)

    Lukkarinen, Jani; Pakkanen, Mikko S.

    2013-01-01

    We study the question whether a Riemann–Stieltjes integral of a positive continuous function with respect to a nonnegative function of bounded variation is positive.......We study the question whether a Riemann–Stieltjes integral of a positive continuous function with respect to a nonnegative function of bounded variation is positive....

  18. Positive technology–A powerful partnership between positive psychology and interactive technology. A discussion of potential and challenges.

    Directory of Open Access Journals (Sweden)

    Sarah Diefenbach

    2017-11-01

    Full Text Available Under the umbrella term "positive computing" concepts of positive psychology are transferred to the domain of human-computer interaction (HCI. In an interdisciplinary community psychologist, computer scientists, designers and others are exploring promising ways how to utilize interactive technology to support wellbeing and human flourishing. Along with this, the recent popularity of smartphone apps aiming at the improvement of health behavior, mindfulness and positive routines, suggests the general acceptance of technology as a facilitator of personal development. Given this, there generally seems a high potential for a technology mediated trigger of positive behavior change, especially in context of positive psychology and resource oriented approaches such as solution-focused coaching. At the same time, there is still a lack of well-founded approaches to design such technology which consider its responsible role as an "interactive coach" and systematically integrate the needed expertise of different disciplines. The present article discusses the general potential and particular challenges to support the goals of positive psychology and human desire for self-improvement through interactive technology and highlights critical steps for a successful partnership between both.

  19. Precise positioning of patients for radiation therapy

    International Nuclear Information System (INIS)

    Verhey, L.J.; Goitein, M.; McNulty, P.; Munzenrider, J.E.; Suit, H.D.

    1982-01-01

    A number of immobilization schemes which permit precise daily positioning of patients for radiation therapy are discussed. Pretreatment and post-treatment radiographs have been taken with the patient in the treatment position and analyzed to determine the amount of intratreatment movement. Studies of patients in the supine, seated and decubitus positions indicate mean movements of less than 1 mm with a standard deviation of less than 1 mm. Patients immobilized in the seated position with a bite block and a mask have a mean movement of about 0.5 mm +/- 0.3 mm (s.d.), and patients immobilized in the supine position with their necks hyperextended for submental therapy evidence a mean movement of about 1.4 mm +/- 0.9 mm (s.d.). With the exception of those used for the decubitus position, the immobilization devices are simply fabricated out of thermoplastic casting materials readily available from orthopedic supply houses. A study of day-to-day reproducibility of patient position using laser alignment and pretreatment radiographs for final verification of position indicates that the initial laser alignment can be used to position a patient within 2.2 mm +/- 1.4 mm (s.d.) of the intended position. These results indicate that rigid immobilization devices can improve the precision of radiotherapy, which would be advantageous with respect to both tumor and normal tissue coverage in certain situations

  20. Analysis of Naval Ammunition Stock Positioning

    Science.gov (United States)

    2015-12-01

    not manipulated to be in favor of any system based on the assumption that stock positioned closer to demand would result in more favorable delivery...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA MBA PROFESSIONAL REPORT ANALYSIS OF NAVAL AMMUNITION STOCK POSITIONING...professional report 4. TITLE AND SUBTITLE ANALYSIS OF NAVAL AMMUNITION STOCK POSITIONING 5. FUNDING NUMBERS 6. AUTHOR(S) David Sharp and Eric

  1. Single-position Hall effect measurements

    DEFF Research Database (Denmark)

    2014-01-01

    A method for determining a distance (Y) between a first position on and an electrical boundary (34) of a test sample by a multi-point probe comprising four contact elements, comprising: contacting the test sample with the four contact elements (20,22,24,26) at the first position, applying a magne...

  2. Manifolds of positive scalar curvature

    Energy Technology Data Exchange (ETDEWEB)

    Stolz, S [Department of Mathematics, University of Notre Dame, Notre Dame (United States)

    2002-08-15

    This lecture gives an survey on the problem of finding a positive scalar curvature metric on a closed manifold. The Gromov-Lawson-Rosenberg conjecture and its relation to the Baum-Connes conjecture are discussed and the problem of finding a positive Ricci curvature metric on a closed manifold is explained.

  3. 5th International Symposium on Positive Systems

    CERN Document Server

    Farina, Lorenzo; Setola, Roberto; Germani, Alfredo

    2017-01-01

    This book presents high-quality original contributions on positive systems, including topics such as: monotone dynamical systems in mathematical biology and game theory; mathematical developments for networked systems in biology, chemistry and the social sciences; linear and nonlinear positive operators; dynamical analysis, observation and control of positive distributed parameter systems; stochastic realization theory; biological systems with positive variables and positive controls; iterated function systems; nonnegative dynamic processes; and dimensioning problems for collaborative systems. The book comprises a selection of the best papers presented at the POSTA 2016, the 5th International Symposium on Positive Systems, which was held in Rome, Italy, in September 2016. This conference series represents a targeted response to the growing need for research that reports on and critically discusses a wide range of topics concerning the theory and applications of positive systems.

  4. Positionality at the Center

    Directory of Open Access Journals (Sweden)

    Catherine Vanner

    2015-11-01

    Full Text Available As a Western feminist supporting and researching gender equality in education in postcolonial contexts, I often wonder: Am I doing more harm than good? The privilege of my social location means that my efforts to support education in postcolonial contexts risk being patronizing, insulting, threatening, imperialist, and recolonizing. Yet neglecting and ignoring postcolonial contexts similarly reflects and reproduces a privileged position. I provide a tentative framework designed to address positionality, power, and privilege while creating an ethical research process for working in a postcolonial context. Beginning with an identification of positionality, the objectives of research, and guiding theoretical frameworks to situate the research in relation to the participants and context, I proceed to establish a methodology designed to minimize the negative effects of power and maximize participants’ empowerment. I position myself as a bricoleur, layering feminist standpoint theory and postcolonial theory, and propose the collaborative data collection and analysis techniques, with particular attention to ethical and cultural sensitivity, using a social constructivist approach to grounded theory. This article highlights the need for Western researchers to reflect upon the power dynamics of their research in postcolonial contexts and develop a strategy for conducting empowering research that prevents the misrepresentation and exploitation of participants. Observations from my doctoral thesis data collection provide examples of how these concepts were operationalized in practice as well as reflections on the disconnect between theorizing and conducting ethical research in postcolonial contexts.

  5. Seismic characteristics and identification of negative flower structures, positive flower structures, and positive structural inversion

    Energy Technology Data Exchange (ETDEWEB)

    Harding, T.P.

    1985-04-01

    Negative and positive flower structures and positive inverted structures imply specific modes of formation, and their distinctive characteristics make them important criteria for the identification of certain structural styles. A negative flower structure from the Andaman Sea consists of a shallow synform bounded by upward-spreading strands of a wrench fault that have mostly normal separations. Paralleling monoclines and oblique, en echelon normal faults flank the divergent wrench fault. A positive flower structure from the Ardmore basin, Oklahoma, consists of a shallow antiform displaced by the upward diverging strands of a wrench fault that have mostly reverse separations. En echelon folds are present on either side of this convergent wrench fault. Positive structural inversion at the Rambutan oil field, South Sumatra basin, has formed a shallow anticlinorium and has partly uplifted the underlying graben. Deeper fault segments bounding the graben have retained their normal fault profiles, but at shallow levels some of these faults have reverse separations.

  6. Angular Positioning Sensor for Space Mechanisms

    Science.gov (United States)

    Steiner, Nicolas; Chapuis, Dominique

    2013-09-01

    Angular position sensors are used on various rotating mechanisms such as solar array drive mechanisms, antenna pointing mechanisms, scientific instruments, motors or actuators.Now a days, potentiometers and encoders are mainly used for angular measurement purposes. Both of them have their own pros and cons.As alternative, Ruag Space Switzerland Nyon (RSSN) is developing and qualifying two innovative technologies of angular position sensors which offer easy implementation, medium to very high lifetime and high flexibility with regards to the output signal shape/type.The Brushed angular position sensor uses space qualified processes which are already flying on RSSN's sliprings for many years. A large variety of output signal shape can be implemented to fulfill customer requirements (digital, analog, customized, etc.).The contactless angular position sensor consists in a new radiation hard Application Specific Integrated Circuit (ASIC) based on the Hall effect and providing the angular position without complex processing algorithm.

  7. Why Libertarians Should Reject Positive Rights

    Directory of Open Access Journals (Sweden)

    Joshua Katz

    2009-01-01

    Full Text Available Maloberti, in “Why Libertarians Should Accept Positive Rights” argues that, as normally presented, libertarianism entails anarchism. He argues that libertarians should, therefore, accept a limited form of positive rights, which will allow for the creation of a libertarian government. In this paper, it is argued that the entailment of anarchism is not a problem for libertarianism, and that the form of positive rights endorsed by Maloberti is unfounded, ill-defined, and inconsistent with libertarian notions of individual freedom. It is further argued that Maloberti’s positive rights, as defined in his paper, cannot withstand the analysis prompted by Austrian value theory.

  8. A Method for The Assessing of Reliability Characteristics Relevant to an Assumed Position-Fixing Accuracy in Navigational Positioning Systems

    Directory of Open Access Journals (Sweden)

    Specht Cezary

    2016-09-01

    Full Text Available This paper presents a method which makes it possible to determine reliability characteristics of navigational positioning systems, relevant to an assumed value of permissible error in position fixing. The method allows to calculate: availability , reliability as well as operation continuity of position fixing system for an assumed, determined on the basis of formal requirements - both worldwide and national, position-fixing accuracy. The proposed mathematical model allows to satisfy, by any navigational positioning system, not only requirements as to position-fixing accuracy of a given navigational application (for air , sea or land traffic but also the remaining characteristics associated with technical serviceability of a system.

  9. Signature Strengths in Positive Psychology

    Science.gov (United States)

    Molony, Terry; Henwood, Maureen

    2010-01-01

    Positive psychology can be thought of as the scientific study of what is "right about people" as opposed to the traditional focus on the healing of psychological pain or trauma. The philosophical roots of positive psychology can be traced back to Confucianism, Taoism, Buddhism, Hinduism, Judaism, Christianity, as well as Islamic and Athenian…

  10. Supine Percutaneous Nephrolithotripsy in Double-S Position.

    Science.gov (United States)

    Giusti, Giuseppe; De Lisa, Antonello

    2018-01-01

    At present, the percutaneous nephrolithotripsy (PCNL) is performed both in supine and in prone position. The aim of this paper is to describe an innovative position during PCNL. We describe a supine position. The patient's legs are slightly abducted at the hips. The thorax is laterally tilted (inclination 30°-35°) and kept in the right position by one or two gel pads placed between the scapula and the vertebrae. External genitalia can be accessed at any time, so that it is always possible to use flexible instruments in the upper urinary tract. We used this position for a period of 12 months to treat with PCNL 45 patients with renal lithiasis. All the procedures were successfully completed without complications, using the position we are describing. The following are some of its benefits: an easier positioning of the patient; a better exposure of the flank for an easier access to the posterior renal calyces of the kidney; a lower risk of pressure injuries compared to positions foreseeing the use of knee crutches; the possibility of combined procedures (ECIRS) through the use of flexible instruments; and a good fluoroscopic visualization of the kidney not overlapped by the vertebrae. This position is effective, safe, easy, and quick to prepare and allows for combined anterograde/retrograde operations.

  11. ESTRO ACROP guidelines for positioning, immobilisation and position verification of head and neck patients for radiation therapists

    Directory of Open Access Journals (Sweden)

    Michelle Leech

    2017-03-01

    Full Text Available Background and purpose: Over the last decade, the management of locally advanced head and neck cancers (HNCs has seen a substantial increase in the use of chemoradiation. These guidelines have been developed to assist Radiation TherapisTs (RTTs in positioning, immobilisation and position verification for head and neck cancer patients. Materials and methods: A critical review of the literature was undertaken by the writing committee.Based on the literature review, a survey was developed to ascertain the current positioning, immobilisation and position verification methods for head and neck radiation therapy across Europe. The survey was translated into Italian, German, Greek, Portuguese, Russian, Croatian, French and Spanish.Guidelines were subsequently developed by the writing committee. Results: Results from the survey indicated that a wide variety of treatment practices and treatment verification protocols are in operation for head and neck cancer patients across Europe currently.The guidelines developed are based on the experience and expertise of the writing committee, remaining cognisant of the variations in imaging and immobilisation techniques used currently in Europe. Conclusions: These guidelines have been developed to provide RTTs with guidance on positioning, immobilisation and position verification of HNC patients. The guidelines will also provide RTTs with the means to critically reflect on their own daily clinical practice with this patient group. Keywords: Head and neck, Immobilisation, Positioning, Verification

  12. Corrosion behavior of a positive graphite electrode in vanadium redox flow battery

    International Nuclear Information System (INIS)

    Liu Huijun; Xu Qian; Yan Chuanwei; Qiao Yonglian

    2011-01-01

    Graphical abstract: The overpotential for gas evolution on positive graphite electrode decreases due to the functional groups of COOH and C=O introduced on the surface of graphite electrode during corrosion process, which can self-catalyze the oxidation of carbon atoms therefore, accelerates corrosion process. Highlights: → Initial potential for gas evolution is higher than 1.60 V vs SCE. → Factors affecting the graphite corrosion are investigated. → Functional groups of COOH and C=O introduced during corrosion process. → The groups can self-catalyze the oxidation of carbon atoms. - Abstract: The graphite plate is easily suffered from corosion because of CO 2 evolution when it acts as the positive electrode for vanadium redox flow battery. The aim is to obtain the initial potential for gas evolution on a positive graphite electrode in 2 mol dm -3 H 2 SO 4 + 2 mol dm -3 VOSO 4 solution. The effects of polarization potential, operating temperature and polarization time on extent of graphite corrosion are investigated by potentiodynamic and potentiostatic techniques. The surface characteristics of graphite electrode before and after corrosion are examined by scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy. The results show that the gas begins to evolve on the graphite electrode when the anodic polarization potential is higher than 1.60 V vs saturated calomel electrode at 20 deg. C. The CO 2 evolution on the graphite electrode can lead to intergranular corrosion of the graphite when the polarization potential reaches 1.75 V. In addition, the functional groups of COOH and C=O introduced on the surface of graphite electrode during corrosion can catalyze the formation of CO 2 , therefore, accelerates the corrosion rate of graphite electrode.

  13. Control rod position detector for nuclear reactor

    International Nuclear Information System (INIS)

    Kudo, Mitsuru; Fujiwara, Hiroshi.

    1981-01-01

    Purpose: To improve the reliability of a control rod position detector by detecting a reactive code with a combination of control rod position change signals produced from vertical and horizontal axis decoders, generation an error signal and thus simultaneously detecting the operation of more than two lead switches. Constitution: Horizontal and vertical axis position signals responsive to changes in the control rod position are applied from lead switches connected in a predetermined matrix connection corresponding to the notches of the positions of respective position detecting probes, the reactive output from the decoder is detected by a reactive code detecting circuit, which in turn generates a fault signal, and the control rod position code converted in a notch number generating circuit is converted to a predetermined value indicating invalidity. Accordingly, a fault caused by the simultaneous operation of a plurality of failed lead switches can be effectively detected. (Yoshino, Y.)

  14. Fractional-Order Control of Pneumatic Position Servosystems

    Directory of Open Access Journals (Sweden)

    Cao Junyi

    2011-01-01

    Full Text Available A fractional-order control strategy for pneumatic position servosystem is presented in this paper. The idea of the fractional calculus application to control theory was introduced in many works, and its advantages were proved. However, the realization of fractional-order controllers for pneumatic position servosystems has not been investigated. Based on the relationship between the pressure in cylinder and the rate of mass flow into the cylinder, the dynamic model of pneumatic position servo system is established. The fractional-order controller for pneumatic position servo and its implementation in industrial computer is designed. The experiments with fractional-order controller are carried out under various conditions, which include sine position signal with different frequency and amplitude, step position signal, and variety inertial load. The results show the effectiveness of the proposed scheme and verify their fine control performance for pneumatic position servo system.

  15. Maintaining positive

    OpenAIRE

    Gheorghe Gh. IONESCU; Adina Letitia NEGRUSA

    2004-01-01

    Maintaining positive work-force relationships includes in effective labor-management relations and making appropriate responses to current employee issues. Among the major current employee issues are protection from arbitrary dismissal, drug and alcohol abuse, privacy rights and family maters and they impact work. In our paper we discus two problems: first, the meanings of industrial democracy; second, the three principal operational concepts of industrial democracy (1) industrial democracy t...

  16. Fabrication of porous anodic alumina using normal anodization and pulse anodization

    Science.gov (United States)

    Chin, I. K.; Yam, F. K.; Hassan, Z.

    2015-05-01

    This article reports on the fabrication of porous anodic alumina (PAA) by two-step anodizing the low purity commercial aluminum sheets at room temperature. Different variations of the second-step anodization were conducted: normal anodization (NA) with direct current potential difference; pulse anodization (PA) alternate between potential differences of 10 V and 0 V; hybrid pulse anodization (HPA) alternate between potential differences of 10 V and -2 V. The method influenced the film homogeneity of the PAA and the most homogeneous structure was obtained via PA. The morphological properties are further elucidated using measured current-transient profiles. The absent of current rise profile in PA indicates the anodization temperature and dissolution of the PAA structure were greatly reduced by alternating potential differences.

  17. Cathodoluminescence study of anodic nanochannel alumina

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Q.X. [Department of Electrical and Electronic Engineering, Saga University, Honjo-1, Saga, 840-8502 (Japan)]. E-mail: guoq@cc.saga-u.ac.jp; Hachiya, Y. [Department of Electrical and Electronic Engineering, Saga University, Honjo-1, Saga, 840-8502 (Japan); Tanaka, T. [Department of Electrical and Electronic Engineering, Saga University, Honjo-1, Saga, 840-8502 (Japan); Nishio, M. [Department of Electrical and Electronic Engineering, Saga University, Honjo-1, Saga, 840-8502 (Japan); Ogawa, H. [Department of Electrical and Electronic Engineering, Saga University, Honjo-1, Saga, 840-8502 (Japan)

    2006-07-15

    Nanochannel alumina (NCA) templates with highly ordered pore arrays were prepared by anodizing pure aluminum foil in acid solutions. Cathodoluminescence measurements reveal that a blue emission band appears at around 2.8 eV and its energy position depends on measurement temperature and pore size of NCA. The shift of the blue emission band energy with temperature is ascribed to the variations of electron-phonon interactions. X-ray absorption near-edge fine structure results show that the blue emission band shift with pore size is due to the local environment change of atoms in NCA.

  18. [Radiotherapy in node-positive prostate cancer].

    Science.gov (United States)

    Bottke, D; Bartkowiak, D; Bolenz, C; Wiegel, T

    2016-03-01

    There are numerous randomized trials to guide the management of patients with localized (and metastatic) prostate cancer, but only a few (mostly retrospective) studies have specifically addressed node-positive patients. Therefore, there is uncertainty regarding optimal treatment in this situation. Current guidelines recommend long-term androgen deprivation therapy (ADT) alone or radiotherapy plus long-term ADT as treatment options. This overview summarizes the existing literature on the use of radiotherapy for node-positive prostate cancer as definitive treatment and as adjuvant or salvage therapy after radical prostatectomy. In this context, we also discuss several PET tracers in the imaging evaluation of patients with biochemical recurrence of prostate cancer after radical prostatectomy. As for definitive treatment, retrospective studies suggest that ADT plus radiotherapy improves overall survival compared with ADT alone. These studies also consistently demonstrated that many patients with node-positive prostate cancer can achieve long-term survival - and are likely curable - with aggressive therapy. The beneficial impact of adjuvant radiotherapy on survival in patients with pN1 prostate cancer seems to be highly influenced by tumor characteristics. Men with ≤ 2 positive lymph nodes in the presence of intermediate- to high-grade disease, or positive margins, and those with 3 or 4 positive lymph nodes are the ideal candidates for adjuvant radiotherapy (plus long-term ADT) after surgery. There is a need for randomized trials to further examine the potential role of radiotherapy as either definitive or adjuvant treatment, for patients with node-positive prostate cancer.

  19. The positive group affect spiral : a dynamic model of the emergence of positive affective similarity in work groups

    NARCIS (Netherlands)

    Walter, F.; Bruch, H.

    This conceptual paper seeks to clarify the process of the emergence of positive collective affect. Specifically, it develops a dynamic model of the emergence of positive affective similarity in work groups. It is suggested that positive group affective similarity and within-group relationship

  20. Positive Psychology and Career Development

    Science.gov (United States)

    Robertson, Peter J.

    2018-01-01

    Positive psychology has been an influential movement within psychology in the early years of the twenty-first century. It is now timely to assess the value of its contribution to career education and guidance. This paper provides a critique of this perspective. Positive psychology can enrich approaches to career development. It can provide a…

  1. False Positives in Exoplanet Detection

    Science.gov (United States)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  2. Modeling electron beam parameters and plasma interface position in an anode plasma electron gun with hydrogen atmosphere

    Science.gov (United States)

    Krauze, A.; Virbulis, J.; Kravtsov, A.

    2018-05-01

    A beam glow discharge based electron gun can be applied as heater for silicon crystal growth systems in which silicon rods are pulled from melt. Impacts of high-energy charged particles cause wear and tear of the gun and generate an additional source of silicon contamination. A steady-state model for electron beam formation has been developed to model the electron gun and optimize its design. Description of the model and first simulation results are presented. It has been shown that the model can simulate dimensions of particle impact areas on the cathode and anode, but further improvements of the model are needed to correctly simulate electron trajectory distribution in the beam and the beam current dependence on the applied gas pressure.

  3. Determining the prevalence of inv-positive and ail-positive Yersinia enterocolitica in pig tonsils using PCR and culture methods.

    Science.gov (United States)

    Stachelska, Milena Alicja

    2017-01-01

    Yersiniosis is believed to be the third most common intestinal zoonosis in the European Union, after campylobacteriosis and salmonellosis. Yersinia enterocolitica is the most common species responsible for human infections. Pigs are regarded as the biggest reservoir of pathogenic Y. enterocolitica strains, which are mainly isolated from pig tonsils. The aim of this paper is to examine the prevalence of inv-positive and ail-positive Y. enterocolitica in pigs which were slaughtered in a Polish abattoir. Real-time PCR and culture methods were used to assess the prevalence of patho- genic Y. enterocolitica strains in pig tonsils. Real-time PCR was applied to detect inv-positive and ail-positive Y. enterocolitica. Y. enterocolitica was also isolated by applying direct plating, unselective (tryptic soy broth) and selective (irgasan-ticarcillin-potassium chlorate bouillon) enrichment. A total of 180 pigs were studied, of which 85% and 32% respectively were found to be infected with inv-positive and ail-positive Y. enterocolitica. The 92 inv-positive and ail-positive isolates, from 57 culture- positive tonsils, underwent bio- and serotyping. The most common was bioserotype 4/O:3, which was found in 53 (93%) out of 57 culture-positive tonsils. Strains of bioserotypes 2/O:5, 2/O:9 and 2/O:5.27 occurred in significantly lower numbers. The prevalence of inv-positive and ail-positive Y. enterocolitica was found to be high in the ton- sils of slaughtered pigs, using real-time PCR. The real-time PCR method for the detection and identification of pathogenic Y. enterocolitica is sensitive and specific, which has been verified by specificity and sensitivity tests using the pure cultures. Serotypes were distinguished from each other using PCR serotyping. The PCR method was essential in forming our conclusions.

  4. Position Error Covariance Matrix Validation and Correction

    Science.gov (United States)

    Frisbee, Joe, Jr.

    2016-01-01

    In order to calculate operationally accurate collision probabilities, the position error covariance matrices predicted at times of closest approach must be sufficiently accurate representations of the position uncertainties. This presentation will discuss why the Gaussian distribution is a reasonable expectation for the position uncertainty and how this assumed distribution type is used in the validation and correction of position error covariance matrices.

  5. Validation of ISTTOK Plasma Position Controller

    International Nuclear Information System (INIS)

    Valcarcel, D. F.; Carvalho, I. S.; Carvalho, B. B.; Fernandes, H.; Silva, C.; Duarte, P.; Duarte, A.; Carvalho, P. J.; Pereira, T.

    2008-01-01

    Active control of plasma position on the ISTTOK tokamak is of extreme importance due to the inherent instability caused by an unfavourable curvature of the external equilibrium magnetic field. The consequences of this instability can be suppressed by applying a dynamic equilibrium field. A digital real-time plasma position control system for ISTTOK has been developed to perform this task. This system uses magnetic measurements to determine the plasma position and feeds the control signal to power supplies that generate the equilibrium fields. After commissioning, the results obtained have shown some discrepancies between the magnetic plasma position reconstruction and several other diagnostics, such as tomography. This discrepancy at some extent is due to the effect of the external magnetic fields on the poloidal magnetic measurements. This work presents a study that addresses this issue. In a future work it will lead to the development of a corrected plasma position algorithm, aiming at obtaining improved performance of plasma discharges and controlled plasma column displacements

  6. Plasma position control on Alcator C

    International Nuclear Information System (INIS)

    Pribyl, P.A.

    1981-05-01

    The Alcator C MHD equilibrium is investigated from the standpoint of determining the plasma position. A review of equilibrium theory is presented, indicating that the central flux surfaces of the plasma should be displaced about 1 to 2 cm from the outermost. Further, the plasma should have a slightly noncircular cross-section. A comparison is made between the observed and predicted profiles. Flux loops sensitive to plasma position generate the error signal for the feedback control circuit. This measurement agrees with other position-sensitive diagnostics, such as limiter heating, and centroids of density, soft x-ray, and electron cyclotron emission. A linear model is developed for the position control feedback system, including the vertical field SCR supply, plasma, and feedback electronics. Operation of the control system agrees well with that predicted by the model, with acceptable plasma position being maintained for the duration of the discharge. The feedback control system is in daily use for Alcator C runs

  7. Curved anode wire chambers for x-ray diffraction applications

    International Nuclear Information System (INIS)

    Perez-Mendez, V.; Wiedenbeck, P.; Wagner, C.N.J.; Woelfel, E.

    1983-01-01

    Curved position sensitive proportional detectors are described. The first has a radius of curvature of 135 mm and a 60 0 angular range. The second has a radius of curvature of 360 mm and a 45 0 angular range. For high quantum efficiency for x-ray energies up to 60 keV, a relatively large x-ray path and high gas pressure are required. The anode wires are suspended in circular arcs by the interaction of a current flowing through them and a magnetic field provided by two permanent magnets placed above and below the wire running parallel to it over the full length of the curved chambers. Anode wire stability under the combined action of the magnetic and electrostatic forces is discussed

  8. Current models of positive mental health

    Directory of Open Access Journals (Sweden)

    Stanojević Dragana Z.

    2012-01-01

    Full Text Available The concept of positive mental health represents not merely the absence of mental disease but presence of high level of happiness and well-being. In this paper we mentioned shortly the earliest concept of mental health, presented by Marie Jahoda in the mid-twentieth century. After that, we described two traditions in understanding and researching of subjective well-being: hedonic and eudaimonic approach. First approach focuses on investigation of positive affects and happiness as emotional and life satisfaction as cognitive component of subjective well-being. Second tradition emphasizes potentials and competences that person develops to the highest level, in personal and social area. Both psychological and social well-being are core concept of positive mental health psychology, designated together as positive functioning. The psychological well-being comprises six dimensions: self-acceptance, positive relations with others, environmental mastery, autonomy, purpose of life and personal growth. Social well-being consists of five dimensions: social integration, social acceptance, social contribution, social actualization and social coherence. By integrating hedonic and eudaimonic well-being as well as absence of mental disease, Corey Keyes introduced concept of complete mental health. People with complete mental health have reported absence of disease during past year and presence of high level of emotional, psychological and social well-being (flourishing. People with incomplete mental health have also reported absence of mental disease but low level of positive functioning (languishing. Keyes thought there are people with complete and incomplete mental illness; both groups report presence of mental disease, but second group has high level of positive functioning. Models of positive mental health are widely used in research studies as well as in programs for prevention and promotion of mental health. .

  9. Genes Underlying Positive Influence Of Prenatal Environmental ...

    African Journals Online (AJOL)

    Genes Underlying Positive Influence Of Prenatal Environmental Enrichment And ... Prenatal environmental enrichment (EE) has been proven to positively affect but ... Conclusion: The negative-positive prenatal effect could contribute to altered ...

  10. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  11. Lateral positioning for critically ill adult patients.

    Science.gov (United States)

    Hewitt, Nicky; Bucknall, Tracey; Faraone, Nardene M

    2016-05-12

    Critically ill patients require regular body position changes to minimize the adverse effects of bed rest, inactivity and immobilization. However, uncertainty surrounds the effectiveness of lateral positioning for improving pulmonary gas exchange, aiding drainage of tracheobronchial secretions and preventing morbidity. In addition, it is unclear whether the perceived risk levied by respiratory and haemodynamic instability upon turning critically ill patients outweighs the respiratory benefits of side-to-side rotation. Thus, lack of certainty may contribute to variation in positioning practice and equivocal patient outcomes. To evaluate effects of the lateral position compared with other body positions on patient outcomes (mortality, morbidity and clinical adverse events) in critically ill adult patients. (Clinical adverse events include hypoxaemia, hypotension, low oxygen delivery and global indicators of impaired tissue oxygenation.) We examined single use of the lateral position (i.e. on the right or left side) and repeat use of the lateral position (i.e. lateral positioning) within a positioning schedule. We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 5), MEDLINE (1950 to 23 May 2015), the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1937 to 23 May 2015), the Allied and Complementary Medicine Database (AMED) (1984 to 23 May 2015), Latin American Caribbean Health Sciences Literature (LILACS) (1901 to 23 May 2015), Web of Science (1945 to 23 May 2015), Index to Theses in Great Britain and Ireland (1950 to 23 May 2015), Trove (2009 to 23 May 2015; previously Australasian Digital Theses Program (1997 to December 2008)) and Proquest Dissertations and Theses (2009 to 23 May 2015; previously Proquest Digital Dissertations (1980 to 23 May 2015)). We handsearched the reference lists of potentially relevant reports and two nursing journals. We included randomized and quasi-randomized trials examining effects of

  12. Theoretical optimum of implant positional index design.

    Science.gov (United States)

    Semper, W; Kraft, S; Krüger, T; Nelson, K

    2009-08-01

    Rotational freedom of the implant-abutment connection influences its screw joint stability; for optimization, influential factors need to be evaluated based on a previously developed closed formula. The underlying hypothesis is that the manufacturing tolerances, geometric pattern, and dimensions of the index do not influence positional stability. We used the dimensions of 5 commonly used implant systems with a clearance of 20 microm to calculate the extent of rotational freedom; a 3D simulation (SolidWorks) validated the analytical findings. Polygonal positional indices showed the highest degrees of rotational freedom. The polygonal profile displayed higher positional stability than the polygons, but less positional accuracy than the cam-groove connection. Features of a maximal rotation-safe positional index were determined. The analytical calculation of rotational freedom of implant positional indices is possible. Rotational freedom is dependent on the geometric design of the index and may be decreased by incorporating specific aspects into the positional index design.

  13. Postural hemodynamic changes after turning to prone position

    Directory of Open Access Journals (Sweden)

    Микола Віталійович Лизогуб

    2015-03-01

    Full Text Available Background of study. Prone position is one of the most complex positions for anesthesiologist as it is accompanied by several physiological changes that can lead to specific complications. Hemodynamic changes are most controversial.Aim of study was to establish hemodynamic changes in non-anaesthetized patients in prone position depending on body mass index.Material and methods. We examined central hemodynamics in 40 patients the day before surgery using thoracic rheography in supine position, in prone position 5 min after turning and in prone position 20 min after turning. Patients were divided into 2 groups according to body mass index (18-25 and 26-35.Results. Patients with normal body weight did not have any hemodynamic changes after turning to prone position. Patients with increased body weight had higher cardiac index. After turning to prone position obese patients’ cardiac output and cardiac index reduced 22% comparing with supine position. After 20 min in prone position these hemodynamic parameters were found to be reduced to the same level.Conclusion. Significant hemodynamic changes after turning from supine to prone position were revealed only in patients with increased body mass index. In these patients cardiac index in prone position was reduced by 22% comparing to supine position

  14. Supine Percutaneous Nephrolithotripsy in Double-S Position

    Directory of Open Access Journals (Sweden)

    Giuseppe Giusti

    2018-01-01

    Full Text Available Background. At present, the percutaneous nephrolithotripsy (PCNL is performed both in supine and in prone position. The aim of this paper is to describe an innovative position during PCNL. Methods. We describe a supine position. The patient’s legs are slightly abducted at the hips. The thorax is laterally tilted (inclination 30°–35° and kept in the right position by one or two gel pads placed between the scapula and the vertebrae. External genitalia can be accessed at any time, so that it is always possible to use flexible instruments in the upper urinary tract. We used this position for a period of 12 months to treat with PCNL 45 patients with renal lithiasis. Results. All the procedures were successfully completed without complications, using the position we are describing. The following are some of its benefits: an easier positioning of the patient; a better exposure of the flank for an easier access to the posterior renal calyces of the kidney; a lower risk of pressure injuries compared to positions foreseeing the use of knee crutches; the possibility of combined procedures (ECIRS through the use of flexible instruments; and a good fluoroscopic visualization of the kidney not overlapped by the vertebrae. Conclusions. This position is effective, safe, easy, and quick to prepare and allows for combined anterograde/retrograde operations.

  15. Side-emitting fiber optic position sensor

    Science.gov (United States)

    Weiss, Jonathan D [Albuquerque, NM

    2008-02-12

    A side-emitting fiber optic position sensor and method of determining an unknown position of an object by using the sensor. In one embodiment, a concentrated beam of light source illuminates the side of a side-emitting fiber optic at an unknown axial position along the fiber's length. Some of this side-illuminated light is in-scattered into the fiber and captured. As the captured light is guided down the fiber, its intensity decreases due to loss from side-emission away from the fiber and from bulk absorption within the fiber. By measuring the intensity of light emitted from one (or both) ends of the fiber with a photodetector(s), the axial position of the light source is determined by comparing the photodetector's signal to a calibrated response curve, look-up table, or by using a mathematical model. Alternatively, the side-emitting fiber is illuminated at one end, while a photodetector measures the intensity of light emitted from the side of the fiber, at an unknown position. As the photodetector moves further away from the illuminated end, the detector's signal strength decreases due to loss from side-emission and/or bulk absorption. As before, the detector's signal is correlated to a unique position along the fiber.

  16. Why Libertarians Should Reject Positive Rights

    OpenAIRE

    Joshua Katz

    2009-01-01

    Maloberti, in “Why Libertarians Should Accept Positive Rights” argues that, as normally presented, libertarianism entails anarchism. He argues that libertarians should, therefore, accept a limited form of positive rights, which will allow for the creation of a libertarian government. In this paper, it is argued that the entailment of anarchism is not a problem for libertarianism, and that the form of positive rights endorsed by Maloberti is unfounded, ill-defined, and inconsistent with libe...

  17. Position Statement on Active Outdoor Play

    OpenAIRE

    Tremblay, Mark S.; Gray, Casey; Babcock, Shawna; Barnes, Joel; Costas Bradstreet, Christa; Carr, Dawn; Chabot, Guylaine; Choquette, Louise; Chorney, David; Collyer, Cam; Herrington, Susan; Janson, Katherine; Janssen, Ian; Larouche, Richard; Pickett, William

    2015-01-01

    A diverse, cross-sectorial group of partners, stakeholders and researchers, collaborated to develop an evidence-informed Position Statement on active outdoor play for children aged 3–12 years. The Position Statement was created in response to practitioner, academic, legal, insurance and public debate, dialogue and disagreement on the relative benefits and harms of active (including risky) outdoor play. The Position Statement development process was informed by two systematic reviews, a critic...

  18. tDCS over the left prefrontal cortex enhances cognitive control for positive affective stimuli.

    Directory of Open Access Journals (Sweden)

    Marie-Anne Vanderhasselt

    Full Text Available Transcranial Direct Current Stimulation (tDCS is a neuromodulation technique with promising results for enhancing cognitive information processes. So far, however, research has mainly focused on the effects of tDCS on cognitive control operations for non-emotional material. Therefore, our aim was to investigate the effects on cognitive control considering negative versus positive material. For this sham-controlled, within-subjects study, we selected a homogeneous sample of twenty-five healthy participants. By using behavioral measures and event related potentials (ERP as indexes, we aimed to investigate whether a single session of anodal tDCS of the left dorsolateral prefrontal cortex (DLPFC would have specific effects in enhancing cognitive control for positive and negative valenced stimuli. After tDCS over the left DLPFC (and not sham control stimulation, we observed more negative N450 amplitudes along with faster reaction times when inhibiting a habitual response to happy compared to sad facial expressions. Gender did not influence the effects of tDCS on cognitive control for emotional information. In line with the Valence Theory of side-lateralized activity, this stimulation protocol might have led to a left dominant (relative to right prefrontal cortical activity, resulting in augmented cognitive control specifically for positive relative to negative stimuli. To verify that tDCS induces effects that are in line with all aspects of the well known Valence Theory, future research should investigate the effects of tDCS over the left vs. right DLPFC on cognitive control for emotional information.

  19. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  20. Front-end circuit for position sensitive silicon and vacuum tube photomultipliers with gain control and depth of interaction measurement

    International Nuclear Information System (INIS)

    Herrero, Vicente; Colom, Ricardo; Gadea, Rafael; Lerche, Christoph W.; Cerda, Joaquin; Sebastia, Angel; Benlloch, Jose M.

    2007-01-01

    Silicon Photomultipliers, though still under development for mass production, may be an alternative to traditional Vacuum Photomultipliers Tubes (VPMT). As a consequence, electronic front-ends initially designed for VPMT will need to be modified. In this simulation, an improved architecture is presented which is able to obtain impact position and depth of interaction of a gamma ray within a continuous scintillation crystal, using either kind of PM. A current sensitive preamplifier stage with individual gain adjustment interfaces the multi-anode PM outputs with a current division resistor network. The preamplifier stage allows to improve front-end processing delay and temporal resolution behavior as well as to increase impact position calculation resolution. Depth of interaction (DOI) is calculated from the width of the scintillation light distribution, which is related to the sum of voltages in resistor network input nodes. This operation is done by means of a high-speed current mode scheme

  1. Hybrid integrated sensor for position measurement

    International Nuclear Information System (INIS)

    Schmidt, B.; Schott, H.; Just, H.-J.

    1986-01-01

    The design, fabrication and performance of an integrated two-dimensional position sensitive photodetector are presented. The optoelectronic device used as sensitive element in the circuit is a full area position sensitive photodiode (PPD) with high linearity over the full sensitive area. The PPD is integrated with the analog electronics in a hybrid circuit using thick film technology. The analog electronics includes the signal amplification and the signal conditioning to form the output signals proportional to the light beam center position at the sensor surface and an output signal proportional to the light beam intensity. Using hybrid integration a new position sensitive transducer is developed giving output signals, transmiting in large distances without problems and driving directly actuators in any control system

  2. Positivity of linear maps under tensor powers

    Energy Technology Data Exchange (ETDEWEB)

    Müller-Hermes, Alexander, E-mail: muellerh@ma.tum.de; Wolf, Michael M., E-mail: m.wolf@tum.de [Zentrum Mathematik, Technische Universität München, 85748 Garching (Germany); Reeb, David, E-mail: reeb.qit@gmail.com [Zentrum Mathematik, Technische Universität München, 85748 Garching (Germany); Institute for Theoretical Physics, Leibniz Universität Hannover, 30167 Hannover (Germany)

    2016-01-15

    We investigate linear maps between matrix algebras that remain positive under tensor powers, i.e., under tensoring with n copies of themselves. Completely positive and completely co-positive maps are trivial examples of this kind. We show that for every n ∈ ℕ, there exist non-trivial maps with this property and that for two-dimensional Hilbert spaces there is no non-trivial map for which this holds for all n. For higher dimensions, we reduce the existence question of such non-trivial “tensor-stable positive maps” to a one-parameter family of maps and show that an affirmative answer would imply the existence of non-positive partial transpose bound entanglement. As an application, we show that any tensor-stable positive map that is not completely positive yields an upper bound on the quantum channel capacity, which for the transposition map gives the well-known cb-norm bound. We, furthermore, show that the latter is an upper bound even for the local operations and classical communications-assisted quantum capacity, and that moreover it is a strong converse rate for this task.

  3. How positioning strategies affect co-branding outcomes

    Directory of Open Access Journals (Sweden)

    Hilary Wason

    2015-12-01

    Full Text Available Co-branding is a widely applied strategy, with research indicating differential benefits to the parent brands. Past studies suggest the source of these differences may be due to the partners’ relative market position, and characteristics such as brand familiarity, brand equity and proximity to the consumer have been explored. However, the role of brand positioning has received little attention in the context of co-branding. The current study attempts to address this gap, considering the positioning of a brand and the impact of a co-branding strategy on customer perceptions. Using the Blankson and Kalafatis positioning typology, we explore the impact of co-branding on the parent brand perceptions from a hedonic vs. functional (utilitarian focus. The results suggest that for hedonically oriented positioning strategies, fit between the brands is more important than fit between the product categories in driving positive brand perceptions. For a functionally oriented positioning strategy, the reverse holds, with product fit a more important factor than brand fit in driving post-alliance perceptions.

  4. Positivity of linear maps under tensor powers

    International Nuclear Information System (INIS)

    Müller-Hermes, Alexander; Wolf, Michael M.; Reeb, David

    2016-01-01

    We investigate linear maps between matrix algebras that remain positive under tensor powers, i.e., under tensoring with n copies of themselves. Completely positive and completely co-positive maps are trivial examples of this kind. We show that for every n ∈ ℕ, there exist non-trivial maps with this property and that for two-dimensional Hilbert spaces there is no non-trivial map for which this holds for all n. For higher dimensions, we reduce the existence question of such non-trivial “tensor-stable positive maps” to a one-parameter family of maps and show that an affirmative answer would imply the existence of non-positive partial transpose bound entanglement. As an application, we show that any tensor-stable positive map that is not completely positive yields an upper bound on the quantum channel capacity, which for the transposition map gives the well-known cb-norm bound. We, furthermore, show that the latter is an upper bound even for the local operations and classical communications-assisted quantum capacity, and that moreover it is a strong converse rate for this task

  5. Hypnagogic Exploration: Sleep Positions and Personality.

    Science.gov (United States)

    Domino, George; Bohn, Sarah Ann

    1980-01-01

    Sleep positions, particularly the full fetal position, appear to be related to California Psychological Inventory (CPI) variables of sociability, sense of well being, achievement by conformance, femininity, and social maturity. (Author)

  6. Analytical expression for position sensitivity of linear response beam position monitor having inter-electrode cross talk

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Mukesh, E-mail: mukeshk@rrcat.gov.in [Beam Diagnostics Section, Indus Operations, Beam Dynamics & Diagnostics Division, Raja Ramanna Centre for Advanced Technology, Indore, 452013 MP (India); Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400 094 (India); Ojha, A.; Garg, A.D.; Puntambekar, T.A. [Beam Diagnostics Section, Indus Operations, Beam Dynamics & Diagnostics Division, Raja Ramanna Centre for Advanced Technology, Indore, 452013 MP (India); Senecha, V.K. [Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400 094 (India); Ion Source Lab., Proton Linac & Superconducting Cavities Division, Raja Ramanna Centre for Advanced Technology, Indore, 452013 MP (India)

    2017-02-01

    According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.

  7. Collective irrationality and positive feedback.

    Science.gov (United States)

    Nicolis, Stamatios C; Zabzina, Natalia; Latty, Tanya; Sumpter, David J T

    2011-04-26

    Recent experiments on ants and slime moulds have assessed the degree to which they make rational decisions when presented with a number of alternative food sources or shelter. Ants and slime moulds are just two examples of a wide range of species and biological processes that use positive feedback mechanisms to reach decisions. Here we use a generic, experimentally validated model of positive feedback between group members to show that the probability of taking the best of options depends crucially on the strength of feedback. We show how the probability of choosing the best option can be maximized by applying an optimal feedback strength. Importantly, this optimal value depends on the number of options, so that when we change the number of options the preference of the group changes, producing apparent "irrationalities". We thus reinterpret the idea that collectives show "rational" or "irrational" preferences as being a necessary consequence of the use of positive feedback. We argue that positive feedback is a heuristic which often produces fast and accurate group decision-making, but is always susceptible to apparent irrationality when studied under particular experimental conditions.

  8. Collective irrationality and positive feedback.

    Directory of Open Access Journals (Sweden)

    Stamatios C Nicolis

    Full Text Available Recent experiments on ants and slime moulds have assessed the degree to which they make rational decisions when presented with a number of alternative food sources or shelter. Ants and slime moulds are just two examples of a wide range of species and biological processes that use positive feedback mechanisms to reach decisions. Here we use a generic, experimentally validated model of positive feedback between group members to show that the probability of taking the best of options depends crucially on the strength of feedback. We show how the probability of choosing the best option can be maximized by applying an optimal feedback strength. Importantly, this optimal value depends on the number of options, so that when we change the number of options the preference of the group changes, producing apparent "irrationalities". We thus reinterpret the idea that collectives show "rational" or "irrational" preferences as being a necessary consequence of the use of positive feedback. We argue that positive feedback is a heuristic which often produces fast and accurate group decision-making, but is always susceptible to apparent irrationality when studied under particular experimental conditions.

  9. Foramen magnum position in bipedal mammals.

    Science.gov (United States)

    Russo, Gabrielle A; Kirk, E Christopher

    2013-11-01

    The anterior position of the human foramen magnum is often explained as an adaptation for maintaining balance of the head atop the cervical vertebral column during bipedalism and the assumption of orthograde trunk postures. Accordingly, the relative placement of the foramen magnum on the basicranium has been used to infer bipedal locomotion and hominin status for a number of Mio-Pliocene fossil taxa. Nonetheless, previous studies have struggled to validate the functional link between foramen magnum position and bipedal locomotion. Here, we test the hypothesis that an anteriorly positioned foramen magnum is related to bipedalism through a comparison of basicranial anatomy between bipeds and quadrupeds from three mammalian clades: marsupials, rodents and primates. Additionally, we examine whether strepsirrhine primates that habitually assume orthograde trunk postures exhibit more anteriorly positioned foramina magna compared with non-orthograde strepsirrhines. Our comparative data reveal that bipedal marsupials and rodents have foramina magna that are more anteriorly located than those of quadrupedal close relatives. The foramen magnum is also situated more anteriorly in orthograde strepsirrhines than in pronograde or antipronograde strepsirrhines. Among the primates sampled, humans exhibit the most anteriorly positioned foramina magna. The results of this analysis support the utility of foramen magnum position as an indicator of bipedal locomotion in fossil hominins. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Effect of Anode Magnetic Shield on Magnetic Field and Ion Beam in Cylindrical Hall Thruster

    International Nuclear Information System (INIS)

    Zhao Jie; Wang Shiqing; Liu Jian; Xu Li; Tang Deli; Geng Shaofei

    2010-01-01

    Numerical simulation of the effect of the anode magnetic shielding on the magnetic field and ion beam in a cylindrical Hall thruster is presented. The results show that after the anode is shielded by the magnetic shield, the magnetic field lines near the anode surface are obviously convex curved, the ratio of the magnetic mirror is enhanced, the width of the positive magnetic field gradient becomes larger than that without the anode magnetic shielding, the radial magnetic field component is enhanced, and the discharge plasma turbulence is reduced as a result of keeping the original saddle field profile and the important role the other two saddle field profiles play in restricting electrons. The results of the particle in cell (PIC) numerical simulation show that both the ion number and the energy of the ion beam increase after the anode is shielded by the magnetic shield. In other words, the specific impulse of the cylindrical Hall thruster is enhanced.

  11. Optical properties of alumina membranes prepared by anodic oxidation process

    International Nuclear Information System (INIS)

    Li Zhaojian; Huang Kelong

    2007-01-01

    The luminescence property of anodic alumina membranes (AAMs) with ordered nanopore arrays prepared by electrochemically anodizing aluminum in oxalic acid solutions have been investigated. Photoluminescence emission (PL) measurement shows that a blue PL band occurs in the wavelength ranges of 300-600 nm. The PL intensity and peak position of AAMs depend markedly on the excitation wavelength. A new peak located at 518 nm can be observed under a monitoring wavelength at 429 nm in the photoluminescence excitation (PLE) spectra. Convincing evidences have been presented that the PLE would be associated with the residual aluminum ions in the membrane. The PLE and PL of AAMs, as a function of anodizing times, have been discussed. It is found that the oxalic impurities incorporated in the AAMs would have important influences on the optical properties of AAMs in the initial stage of anodization. The PL and PLE spectra obtained show that there are three optical centers, of which the first is originated from the F + centers in AAMs, the second is correlated with the oxalic impurities incorporated in the AAMs, and the third is associated with the excess aluminum ions in the membrane

  12. Optical properties of alumina membranes prepared by anodic oxidation process

    Energy Technology Data Exchange (ETDEWEB)

    Li Zhaojian [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)], E-mail: lizhaojian_lzj@hotmail.com; Huang Kelong [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)], E-mail: klhuang@mail.csu.edu.cn

    2007-12-15

    The luminescence property of anodic alumina membranes (AAMs) with ordered nanopore arrays prepared by electrochemically anodizing aluminum in oxalic acid solutions have been investigated. Photoluminescence emission (PL) measurement shows that a blue PL band occurs in the wavelength ranges of 300-600 nm. The PL intensity and peak position of AAMs depend markedly on the excitation wavelength. A new peak located at 518 nm can be observed under a monitoring wavelength at 429 nm in the photoluminescence excitation (PLE) spectra. Convincing evidences have been presented that the PLE would be associated with the residual aluminum ions in the membrane. The PLE and PL of AAMs, as a function of anodizing times, have been discussed. It is found that the oxalic impurities incorporated in the AAMs would have important influences on the optical properties of AAMs in the initial stage of anodization. The PL and PLE spectra obtained show that there are three optical centers, of which the first is originated from the F{sup +} centers in AAMs, the second is correlated with the oxalic impurities incorporated in the AAMs, and the third is associated with the excess aluminum ions in the membrane.

  13. Precise Point Positioning

    DEFF Research Database (Denmark)

    Zhang, Xiaohong

    the airborne lidar system misalignment angle by automating the matching of lidar data with ground truth. Kinematic GPS positioning has been widely used, but the available commercial software systems are normally only suitable for the short or medium range kinematic baseline. However, in polar areas, airborne...

  14. Beam Position Monitor Engineering

    International Nuclear Information System (INIS)

    Smith, Stephen R.

    1996-07-01

    The design of beam position monitors often involves challenging system design choices. Position transducers must be robust, accurate, and generate adequate position signal without unduly disturbing the beam. Electronics must be reliable and affordable, usually while meeting tough requirements on precision. accuracy, and dynamic range. These requirements may be difficult to achieve simultaneously, leading the designer into interesting opportunities for optimization or compromise. Some useful techniques and tools are shown. Both finite element analysis and analytic techniques will be used to investigate quasi-static aspects of electromagnetic fields such as the impedance of and the coupling of beam to striplines or buttons. Finite-element tools will be used to understand dynamic aspects of the electromagnetic fields of beams, such as wake-fields and transmission-line and cavity effects in vacuum-to-air feed through. Mathematical modeling of electrical signals through a processing chain will be demonstrated, in particular to illuminate areas where neither a pure time-domain nor a pure frequency-domain analysis is obviously advantageous. Emphasis will be on calculational techniques, in particular on using both time-domain and frequency domain approaches to the applicable parts of interesting problems

  15. Value Positions in E-government strategies

    DEFF Research Database (Denmark)

    Persson, John Stouby; Reinwald, Anja Kaldahl; Skorve, Espen

    2017-01-01

    by value positions deeply enshrined in the traditions of public administration. We present a theory directed con-tent analysis of value positions in the national e-government strategy for Denmark published for the first time in 1994 and latest in 2016. Our comparison of the value positions in the two e......-government strategies show consistency over time when looking at the ideals of professionalism, service, and efficiency. While the least dominant ideal of engagement, has declined. The 22-year timespan separating the development of these two strategies had major technological advances, but little transformational...... impact on Danish e-government strategies in their general value positions. We discuss how our findings contribute to previous research on values in e-government and have practical implications for working with e-government strategies....

  16. Antiproton source beam position system

    International Nuclear Information System (INIS)

    Bagwell, T.; Holmes, S.; McCarthy, J.; Webber, R.

    1984-05-01

    The TeV I Beam Position Monitor (BPM) system is designed to provide a useful diagnostic tool during the commissioning and operational phases of the antiproton source. Simply stated the design goal is to provide single turn position information for intensities of > 1x10 9 particles, and multi-turn (clocked orbit) information for beam intensities of > 1x10 7 particles, both with sub-millimeter resolution. It is anticipated that the system will be used during commissioning for establishing the first turn through the Debuncher and Accumulator, for aligning injection orbits, for providing information necessary to correct closed orbits, and for measuring various machine parameters (e.g. tunes, dispersion, aperture, chromaticity). During normal antiproton operation the system will be used to monitor the beam position throughout the accumulation process

  17. Nucleosome Positioning and Epigenetics

    Science.gov (United States)

    Schwab, David; Bruinsma, Robijn

    2008-03-01

    The role of chromatin structure in gene regulation has recently taken center stage in the field of epigenetics, phenomena that change the phenotype without changing the DNA sequence. Recent work has also shown that nucleosomes, a complex of DNA wrapped around a histone octamer, experience a sequence dependent energy landscape due to the variation in DNA bend stiffness with sequence composition. In this talk, we consider the role nucleosome positioning might play in the formation of heterochromatin, a compact form of DNA generically responsible for gene silencing. In particular, we discuss how different patterns of nucleosome positions, periodic or random, could either facilitate or suppress heterochromatin stability and formation.

  18. Infiltrated SrTiO3:FeCr-based anodes for metalsupported SOFC

    DEFF Research Database (Denmark)

    Blennow Tullmar, Peter; Persson, Åsa Helen; Nielsen, Jimmi

    2012-01-01

    The concept of using highly electronically conducting backbones with subsequent infiltration of electrocatalytic active materials, has recently been used to develop an alternative SOFC design based on a ferritic stainless steel support. The metal-supported SOFC is comprised of porous and highly e...... changes occurring in the anode layer during testing. The results indicate that the STN component in the anode seems to have a positive effect on the corrosion stability of the FeCr-particles in the anode layer.......) and FeCr. Electrochemical characterization and post test SEM analysis have been used to get an insight into the possible degradation mechanisms of this novel electrode infiltrated with Gd-doped CeO2 and Ni. Accelerated oxidation/corrosion experiments have been conducted to evaluate the microstructural...

  19. Efficiency of ozone production by pulsed positive corona discharge in synthetic air

    Energy Technology Data Exchange (ETDEWEB)

    Simek, Milan [Institute of Plasma Physics, Department of Pulsed Plasma Systems, Academy of Sciences of the Czech Republic, Prague (Czech Republic)]. E-mail: simek@ipp.cas.cz; Clupek, Martin [Institute of Plasma Physics, Department of Pulsed Plasma Systems, Academy of Sciences of the Czech Republic, Prague (Czech Republic)

    2002-06-07

    We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short ({approx}150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10{sup -4}-3x10{sup -1} Wh l{sup -1}) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min{sup -1}). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh{sup -1} and 35-110 eV/molecule. (author)

  20. Spherical ion oscillations in a positive polarity gridded inertial-electrostatic confinement device

    Energy Technology Data Exchange (ETDEWEB)

    Bandara, R.; Khachan, J. [Plasma Physics, School of Physics, University of Sydney, Camperdown, New South Wales 2006 (Australia)

    2013-07-15

    A pulsed, positive polarity gridded inertial electrostatic confinement device has been investigated experimentally, using a differential emissive probe and potential traces as primary diagnostics. Large amplitude oscillations in the plasma current and plasma potential were observed within a microsecond of the discharge onset, which are indicative of coherent ion oscillations about a temporarily confined excess of recirculating electron space charge. The magnitude of the depth of the potential well in the established virtual cathode was determined using a differential emissive Langmuir probe, which correlated well to the potential well inferred from the ion oscillation frequency for both hydrogen and argon experiments. It was found that the timescale for ion oscillation dispersion is strongly dependent on the neutral gas density, and weakly dependent on the peak anode voltage. The cessation of the oscillations was found to be due to charge exchange processes converting ions to high velocity neutrals, causing the abrupt de-coherence of the oscillations through an avalanche dispersion in phase space.

  1. Spherical ion oscillations in a positive polarity gridded inertial-electrostatic confinement device

    Science.gov (United States)

    Bandara, R.; Khachan, J.

    2013-07-01

    A pulsed, positive polarity gridded inertial electrostatic confinement device has been investigated experimentally, using a differential emissive probe and potential traces as primary diagnostics. Large amplitude oscillations in the plasma current and plasma potential were observed within a microsecond of the discharge onset, which are indicative of coherent ion oscillations about a temporarily confined excess of recirculating electron space charge. The magnitude of the depth of the potential well in the established virtual cathode was determined using a differential emissive Langmuir probe, which correlated well to the potential well inferred from the ion oscillation frequency for both hydrogen and argon experiments. It was found that the timescale for ion oscillation dispersion is strongly dependent on the neutral gas density, and weakly dependent on the peak anode voltage. The cessation of the oscillations was found to be due to charge exchange processes converting ions to high velocity neutrals, causing the abrupt de-coherence of the oscillations through an avalanche dispersion in phase space.

  2. 5 CFR 214.402 - Career reserved positions.

    Science.gov (United States)

    2010-01-01

    ... collection of taxes and the preparation or review of interpretative opinions. (2) Career reserved positions... review agency designations of general and career reserved positions. If the Office finds that an agency... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Career reserved positions. 214.402...

  3. 20 CFR 655.154 - Additional positive recruitment.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Additional positive recruitment. 655.154... recruitment. (a) Where to conduct additional positive recruitment. The employer must conduct positive recruitment within a multistate region of traditional or expected labor supply where the CO finds that there...

  4. CSR Position in the Top Management Team

    DEFF Research Database (Denmark)

    Strand, Robert

    Recently, a number of positions with corporate social responsibility (CSR) in the position title have been introduced to the top management teams (TMTs) of some of the world’s largest corporations. I explore this phenomenon. I revisit 10 such positions identified in a previous study to add...

  5. Towards Efficient Positional Inverted Index †

    Directory of Open Access Journals (Sweden)

    Petr Procházka

    2017-02-01

    Full Text Available We address the problem of positional indexing in the natural language domain. The positional inverted index contains the information of the word positions. Thus, it is able to recover the original text file, which implies that it is not necessary to store the original file. Our Positional Inverted Self-Index (PISI stores the word position gaps encoded by variable byte code. Inverted lists of single terms are combined into one inverted list that represents the backbone of the text file since it stores the sequence of the indexed words of the original file. The inverted list is synchronized with a presentation layer that stores separators, stop words, as well as variants of the indexed words. The Huffman coding is used to encode the presentation layer. The space complexity of the PISI inverted list is O ( ( N − n ⌈ log 2 b N ⌉ + ( ⌊ N − n α ⌋ + n × ( ⌈ log 2 b n ⌉ + 1 where N is a number of stems, n is a number of unique stems, α is a step/period of the back pointers in the inverted list and b is the size of the word of computer memory given in bits. The space complexity of the presentation layer is O ( − ∑ i = 1 N ⌈ log 2 p i n ( i ⌉ − ∑ j = 1 N ′ ⌈ log 2 p j ′ ⌉ + N with respect to p i n ( i as a probability of a stem variant at position i, p j ′ as the probability of separator or stop word at position j and N ′ as the number of separators and stop words.

  6. Audiological manifestations in HIV-positive adults

    Directory of Open Access Journals (Sweden)

    Carla Gentile Matas

    2014-07-01

    Full Text Available OBJECTIVE:To characterize the findings of behavioral hearing assessment in HIV-positive individuals who received and did not receive antiretroviral treatment.METHODS:This research was a cross-sectional study. The participants were 45 HIV-positive individuals (18 not exposed and 27 exposed to antiretroviral treatment and 30 control-group individuals. All subjects completed an audiological evaluation through pure-tone audiometry, speech audiometry, and high-frequency audiometry.RESULTS:The hearing thresholds obtained by pure-tone audiometry were different between groups. The group that had received antiretroviral treatment had higher thresholds for the frequencies ranging from 250 to 3000 Hz compared with the control group and the group not exposed to treatment. In the range of frequencies from 4000 through 8000 Hz, the HIV-positive groups presented with higher thresholds than did the control group. The hearing thresholds determined by high-frequency audiometry were different between groups, with higher thresholds in the HIV-positive groups.CONCLUSION:HIV-positive individuals presented poorer results in pure-tone and high-frequency audiometry, suggesting impairment of the peripheral auditory pathway. Individuals who received antiretroviral treatment presented poorer results on both tests compared with individuals not exposed to antiretroviral treatment.

  7. Audiological manifestations in HIV-positive adults.

    Science.gov (United States)

    Matas, Carla Gentile; Angrisani, Rosanna Giaffredo; Magliaro, Fernanda Cristina Leite; Segurado, Aluisio Augusto Cotrim

    2014-07-01

    To characterize the findings of behavioral hearing assessment in HIV-positive individuals who received and did not receive antiretroviral treatment. This research was a cross-sectional study. The participants were 45 HIV-positive individuals (18 not exposed and 27 exposed to antiretroviral treatment) and 30 control-group individuals. All subjects completed an audiological evaluation through pure-tone audiometry, speech audiometry, and high-frequency audiometry. The hearing thresholds obtained by pure-tone audiometry were different between groups. The group that had received antiretroviral treatment had higher thresholds for the frequencies ranging from 250 to 3000 Hz compared with the control group and the group not exposed to treatment. In the range of frequencies from 4000 through 8000 Hz, the HIV-positive groups presented with higher thresholds than did the control group. The hearing thresholds determined by high-frequency audiometry were different between groups, with higher thresholds in the HIV-positive groups. HIV-positive individuals presented poorer results in pure-tone and high-frequency audiometry, suggesting impairment of the peripheral auditory pathway. Individuals who received antiretroviral treatment presented poorer results on both tests compared with individuals not exposed to antiretroviral treatment.

  8. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  9. Does the Supine Position Affect the Nasal Profile in Rhinoplasty Patients? A Comparison of Nasal Anthropometric Measurements in Different Body Positions.

    Science.gov (United States)

    Kim, Su Jin; Ryu, In Yong; Kim, Sung Wan; Lee, Kun Hee

    2017-10-16

    Rhinoplasty surgeons are aware that the nasal profile differs according to body position, namely, the erect position in the consultation room vs the supine position on the operating table. It is not clear whether this difference is caused by an optical illusion or skin laxity due to positional change. To evaluate anthropometric measurements of the nose with different body positions and determine whether the supine position affects the nasal profile. In this retrospective study, 103 patients who underwent primary rhinoplasty were enrolled. Preoperatively, all patients underwent lateral cephalography in the erect position, and facial computed tomography (CT), in the supine position. We measured four nasal anthropometric parameters (the nasofrontal, nasolabial, and nasomental angles, and Simon's ratio) on lateral cephalograms and facial CT images, and compared these parameters between the two body positions. The nasofrontal angle was greater on facial CT than on cephalograms (P sex, or body mass index (P > 0.05 each). We found no significant difference (P > 0.05) between the two positions in the nasolabial angle, nasomental angle, or Simon's ratio. The supine position does affect the nasal profile, especially in the radix area. Surgeons need to consider this difference in patients undergoing rhinoplasty. 2. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  10. Vehicle positioning based on UWB technology

    Science.gov (United States)

    Hu, Siquan; Kang, Min; She, Chundong

    2017-08-01

    In recent years, with the rapid increase of the number of urban cars, the vehicle internet is becoming a trend of smart transportion. In such vehicle network, accurate location is very crucial in many new applications such as autopilot, semi-autopilot and Car-to-x communications. UWB technology has been used for indoor closed range positioning and ranging widely, while UWB outdoor positioning and ranging research is relatively less. This paper proposed UWB as the vehicle positioning technology and developed a method based on two-way-ranging (TWR) to solve the ranging problem between vehicles. At the same time, the improved TOA method was used to locate vehicles, which has higher precision compared with traditional GPS or LBS. A hardware module is introduced and the simulation results show that the modules are capable of precise positioning for vehicles in vehicle network.

  11. Future directions for positive body image research.

    Science.gov (United States)

    Halliwell, Emma

    2015-06-01

    The emergence of positive body image research during the last 10 years represents an important shift in the body image literature. The existing evidence provides a strong empirical basis for the study of positive body image and research has begun to address issues of age, gender, ethnicity, culture, development, and intervention in relation to positive body image. This article briefly reviews the existing evidence before outlining directions for future research. Specifically, six areas for future positive body image research are outlined: (a) conceptualization, (b) models, (c) developmental factors, (d) social interactions, (e) cognitive processing style, and (f) interventions. Finally, the potential role of positive body image as a protective factor within the broader body image literature is discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Going positive: The effects of negative and positive advertising on candidate success and voter turnout

    Directory of Open Access Journals (Sweden)

    Liam C Malloy

    2016-01-01

    Full Text Available Given the depth of research on negative advertising in campaigns, scholars have wondered why candidates continue to attack their opponents. We build on this research by considering real-world campaign contexts in which candidates are working in competition with each other and have to react to the decisions of the opposing campaign. Our results suggest that it is never efficacious for candidates to run attack ads, but running positive ads can increase a candidate’s margin of victory. These results are conditioned by two factors: candidates must both stay positive and out-advertise their opponent. Second, the effects of positive advertising are strongest in areas where the candidate is losing or winning by a large margin—areas where they might be tempted to not advertise at all.

  13. Positioning and early mobilisation in stroke.

    Science.gov (United States)

    Keating, Moira; Penney, Maree; Russell, Petra; Bailey, Emma

    Stroke unit care, providing early rehabilitation, improves long-term outcomes for patients following a stroke. Early mobilisation and good positioning are recognised as key aspects of care in stroke units. Nurses working on stroke units have an important role because they are able to implement positioning and early mobilisation strategies 24 hours a day, reducing the risk of complications and improving functional recovery. Patients benefit if nurses work effectively with the therapy team in positioning and early mobilisation. Nurses also need appropriate training and expertise to make best use of specialist equipment.

  14. Relativistic positioning systems: perspectives and prospects

    Science.gov (United States)

    Coll Bartolomé

    2013-11-01

    Relativistic positioning systems are interesting technical objects for applications around the Earth and in the Solar system. But above all else, they are basic scientific objects allowing developing relativity from its own concepts. Some past and future features of relativistic positioning sys- tems, with special attention to the developments that they suggest for an epistemic relativity (relativistic experimental approach to physics), are analyzed. This includes relativistic stereometry, which, together with relativistic positioning systems, allows to introduce the general relativistic notion of (finite) laboratory (space-time region able to perform experiments of finite size).

  15. Position sensitive x-ray detector

    International Nuclear Information System (INIS)

    Macchione, E.L.A.

    1990-01-01

    A multi ware position sensitive gas counter for X-ray detection was developed in our laboratory, making use of commercial delay-lines for position sensing. Six delay-line chips (50 ns delay each, 40 Mhz cut-off frequency) cover a total sensitive length of 150 mm leading to a delay-risetime ratio that allows for a high-resolution position detection. Tests using the 5,9 keV X-ray line from a 55 Fe source and integral linearity better than 0,1% and a maximal differential linearity of ±4,0% were obtained operating the detector with an Ar-C H 4 (90%-10%) gas mixture at 700 torr. Similar tests were performed, using the 8,04 keV line from a Cu x-ray tube. A total resolution of 330 μm, and the same integral and differential linearities were obtained. (author)

  16. 38 CFR 1.892 - Review of positions.

    Science.gov (United States)

    2010-07-01

    ... PROVISIONS Part-Time Career Employment Program § 1.892 Review of positions. Positions becoming vacant, unless... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Review of positions. 1...-time. Among the criteria which may be used when conducting this review are: (a) Mission requirements...

  17. Consistent feeding positions of great tit parents

    NARCIS (Netherlands)

    Lessells, C.M.; Poelman, E.H.; Mateman, A.C.; Cassey, Ph.

    2006-01-01

    When parent birds arrive at the nest to provision their young, their position on the nest rim may influence which chick or chicks are fed. As a result, the consistency of feeding positions of the individual parents, and the difference in position between the parents, may affect how equitably food is

  18. High-precision positioning of radar scatterers

    NARCIS (Netherlands)

    Dheenathayalan, P.; Small, D.; Schubert, A.; Hanssen, R.F.

    2016-01-01

    Remote sensing radar satellites cover wide areas and provide spatially dense measurements, with millions of scatterers. Knowledge of the precise position of each radar scatterer is essential to identify the corresponding object and interpret the estimated deformation. The absolute position accuracy

  19. Stanford Linear Collider magnet positioning

    International Nuclear Information System (INIS)

    Wand, B.T.

    1991-08-01

    For the installation of the Stanford Linear Collider (SLC) the positioning and alignment of the beam line components was performed in several individual steps. In the following the general procedures for each step are outlined. The calculation of ideal coordinates for the magnets in the entire SLC will be discussed in detail. Special emphasis was given to the mathematical algorithms and geometry used in the programs to calculate these ideal positions. 35 refs., 21 figs

  20. Modeling of the anode side of a direct methanol fuel cell with analytical solutions

    International Nuclear Information System (INIS)

    Mosquera, Martin A.; Lizcano-Valbuena, William H.

    2009-01-01

    In this work, analytical solutions were derived (for any methanol oxidation reaction order) for the profiles of methanol concentration and proton current density, by assuming diffusion mass transport mechanism, Tafel kinetics, and fast proton transport in the anodic catalyst layer of a direct methanol fuel cell. An expression for the Thiele modulus that allows to express the anodic overpotential as a function of the cell current and kinetic and mass transfer parameters was obtained. For high cell current densities, it was found that the Thiele modulus (φ 2 ) varies quadratically with cell current density; yielding a simple correlation between anodic overpotential and cell current density. Analytical solutions were derived for the profiles of both local methanol concentration in the catalyst layer and local anodic current density in the catalyst layer. Under the assumptions of the model presented here, in general, the local methanol concentration in the catalyst layer cannot be expressed as an explicit function of the position in the layer. In spite of this, the equations presented here for the anodic overpotential allow the derivation of new semi-empirical equations

  1. Extending family nursing: concepts from positive psychology.

    Science.gov (United States)

    Skerrett, Karen

    2010-11-01

    This article identifies the burgeoning field of positive psychology as an important extension to the knowledge base of family nursing. Representing a new emphasis from the traditional social and human sciences, which have largely focused on problem- and deficit-based approaches, positive psychology focuses on optimal functioning and is an ideal complement to the strengths-based orientation of family nursing. Domains of positive psychology are presented and exemplars of supporting research offered. Finally, suggestions are given for ways to apply concepts from positive psychology to family nursing practice, research, and education.

  2. Positional therapy in sleep apnoea - one fits all? What determines success in positional therapy in sleep apnoea syndrome.

    Directory of Open Access Journals (Sweden)

    Natascha Troester

    Full Text Available Positional therapy is a simple means of therapy in sleep apnoea syndrome, but due to controversial or lacking evidence, it is not widely accepted as appropriate treatment. In this study, we analysed data to positional therapy with regard to successful reduction of AHI and predictors of success.All consecutive patients undergoing polysomnography between 2007 and 2011 were analysed. We used a strict definition of positional sleep apnoea syndrome (supine-exclusive sleep apnoea syndrome and of therapy used. Patients underwent polysomnography initially and during follow-up.1275 patients were evaluated, 112 of which had supine-exclusive sleep apnoea syndrome (AHI 5-66/h, median 13/h, 105 received positional therapy. With this treatment alone 75% (70/105 reached an AHI <5/h, in the follow-up 1 year later 37% (37/105 of these still had AHI<5/h, 46% (43/105 yielded an AHI between 5 and 10/h. Nine patient switched to APAP due to deterioration, 3 wanted to try APAP due to comfort reasons. At the last follow-up, 32% patients (34/105 were still on positional therapy with AHI <5/h. BMI was a predictor for successful reduction of AHI, but success was independent of sex, the presence of obstructive versus central sleep apnoea, severity of sleep apnoea syndrome or co-morbidities.Positional therapy may be a promising therapy option for patients with positional sleep apnoea. With appropriate adherence it yields a reasonable success rate in the clinical routine.

  3. Analysis of tag-position bias in MPSS technology

    Directory of Open Access Journals (Sweden)

    Rattray Magnus

    2006-04-01

    Full Text Available Abstract Background Massively Parallel Signature Sequencing (MPSS technology was recently developed as a high-throughput technology for measuring the concentration of mRNA transcripts in a sample. It has previously been observed that the position of the signature tag in a transcript (distance from 3' end can affect the measurement, but this effect has not been studied in detail. Results We quantify the effect of tag-position bias in Classic and Signature MPSS technology using published data from Arabidopsis, rice and human. We investigate the relationship between measured concentration and tag-position using nonlinear regression methods. The observed relationship is shown to be broadly consistent across different data sets. We find that there exist different and significant biases in both Classic and Signature MPSS data. For Classic MPSS data, genes with tag-position in the middle-range have highest measured abundance on average while genes with tag-position in the high-range, far from the 3' end, show a significant decrease. For Signature MPSS data, high-range tag-position genes tend to have a flatter relationship between tag-position and measured abundance. Thus, our results confirm that the Signature MPSS method fixes a substantial problem with the Classic MPSS method. For both Classic and Signature MPSS data there is a positive correlation between measured abundance and tag-position for low-range tag-position genes. Compared with the effects of mRNA length and number of exons, tag-position bias seems to be more significant in Arabadopsis. The tag-position bias is reflected both in the measured abundance of genes with a significant tag count and in the proportion of unexpressed genes identified. Conclusion Tag-position bias should be taken into consideration when measuring mRNA transcript abundance using MPSS technology, both in Classic and Signature MPSS methods.

  4. CDDIS_VLBI_products_positions

    Data.gov (United States)

    National Aeronautics and Space Administration — Station positions and velocity solutions in Software INdependent EXchange (SINEX) format derived from analysis of Very Long Baseline Interferometry (VLBI) data....

  5. Turning lemonade into lemons: Dampening appraisals reduce positive affect and increase negative affect during positive activity scheduling.

    Science.gov (United States)

    Burr, Leigh-Anne; Javiad, Mahmood; Jell, Grace; Werner-Seidler, Aliza; Dunn, Barnaby D

    2017-04-01

    The way individuals appraise positive emotions may modulate affective experience during positive activity scheduling. Individuals may either engage in dampening appraisals (e.g., think "this is too good to last") or amplifying appraisals (e.g., think "I deserve this"). A cross-over randomized design was used to examine the consequences of these appraisal styles. Participants (N = 43) rated positive affect (PA) and negative affect (NA) during four daily walks in pleasant locations, whilst following dampening, emotion-focus amplifying (focusing on how good one feels), self-focus amplifying (focusing on positive self qualities), or control instructions. There was no difference between the two amplifying and control conditions, which all increased PA and reduced NA during the walks. However, the dampening condition significantly differed from all other conditions, reducing PA and increasing NA during the walk. Individual differences in anhedonia symptoms did not significantly moderate the pattern of findings. This evidence supports the view that dampening appraisals may be one mechanism driving anhedonia and may account for why positive activity scheduling can sometimes backfire when utilized in the clinic. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Universitetsundervisningens (u)mulige position i Akademia

    DEFF Research Database (Denmark)

    Sørensen, Kasper Anthon

    2016-01-01

    uses positioning theory to analyse how six interviewed academics position themselves and others as right and wrong participants in Academia in relation to their teaching and research activities. My analysis shows that a dominant research discourse, driven by a harsh research-publishing obligation...

  7. Low sputum smear positive tuberculosis among pulmonary ...

    African Journals Online (AJOL)

    Low sputum smear positive tuberculosis among pulmonary tuberculosis suspects in a tertiary hospital in Mwanza, Tanzania. ... The risk factors among smear positive TB patients were co-illness (32.5%), previous history of TB (7.5%) and history of positive TB contact (4.7%). These findings also show that as CD4+ T Cells ...

  8. Upper limb position control in fibromyalgia

    Directory of Open Access Journals (Sweden)

    Bardal Ellen

    2012-09-01

    Full Text Available Abstract Background Motor problems are reported by patients with fibromyalgia (FM. However, the mechanisms leading to alterations in motor performance are not well understood. In this study, upper limb position control during sustained isometric contractions was investigated in patients with FM and in healthy controls (HCs. Methods Fifteen female FM patients and 13 HCs were asked to keep a constant upper limb position during sustained elbow flexion and shoulder abduction, respectively. Subjects received real-time visual feedback on limb position and both tasks were performed unloaded and while supporting loads (1, 2, and 3 kg. Accelerations of the dominant upper limb were recorded, with variance (SD of mean position and power spectrum analysis used to characterize limb position control. Normalized power of the acceleration signal was extracted for three frequency bands: 1–3 Hz, 4–7 Hz, and 8–12 Hz. Results Variance increased with load in both tasks (P 0.001 but did not differ significantly between patients and HCs (P > 0.17. Power spectrum analysis showed that the FM patients had a higher proportion of normalized power in the 1–3 Hz band, and a lower proportion of normalized power in the 8–12 Hz band compared to HCs (P 0.05. The results were consistent for all load conditions and for both elbow flexion and shoulder abduction. Conclusion FM patients exhibit an altered neuromuscular strategy for upper limb position control compared to HCs. The predominance of low-frequency limb oscillations among FM patients may indicate a sensory deficit.

  9. Positioning accuracy of the neurotron 1000

    International Nuclear Information System (INIS)

    Cox, Richard S.; Murphy, Martin J.

    1995-01-01

    Purpose: The Neurotron 1000 is a novel treatment machine under development for frameless stereotaxic radiosurgery that consists of a compact X-band accelerator mounted on a robotic arm. The therapy beam is guided to the lesion by an imaging system, which includes two diagnostic x-ray cameras that view the patient during treatment. Patient position and motion are measured by the imaging system and appropriate corrections are communicated in real time to the robotic arm for beam targeting and motion tracking. The three tests reported here measured the pointing accuracy of the therapy beam and the present capability of the imaging guidance system. Materials and Methods: 1) The positioning and pointing test measured the ability of the robotic arm to direct the beam through a test isocenter from arbitrary arm positions. The test isocenter was marked by a small light-sensitive crystal and the beam axis was simulated by a laser. The robot was directed to move the linac to a variety of positions, aiming the laser at the crystal detector from each position. The distance of the beam axis from the crystal was measured for each robot position. 2) The imaging-guidance system was tested by moving phantoms about in the field of view of the camera by precisely known displacements and comparing the guidance system's measurement of the phantom position with the its actual position. 3) The system's overall pointing and tracking capability was measured by an end-to-end test using a dosimetric phantom containing radiochromic film. The phantom was imaged by CT to locate the center of the cubical film package. A set of isocentric robotic paths was calculated to produce a spherical dose distribution at the center of the film package. The phantom with the film was then irradiated by the therapy beam as the robot executed the path, with the imaging system providing the beam targeting directions. Results: 1) The positioning and pointing test was performed for paths consisting of spirals and

  10. Evaluation of the Positive Re-Entry in Corrections Program: A Positive Psychology Intervention With Prison Inmates.

    Science.gov (United States)

    Huynh, Kim H; Hall, Brittany; Hurst, Mark A; Bikos, Lynette H

    2015-08-01

    Two groups of male inmates (n = 31, n = 31) participated in the Positive Re-Entry in Corrections Program (PRCP). This positive psychology intervention focused on teaching offenders skills that facilitate re-entry into the community. Offenders participated in weekly lectures, discussions, and homework assignments focused on positive psychology principles. The two groups differed in duration of treatment (8 weeks and 12 weeks). Participants completed pre- and post-intervention measures of gratitude, hope, and life satisfaction. Using a 2 × 2 mixed design ANOVA, we hypothesized that the intervention (with two between-subjects levels of 8 and 12 weeks) and duration (with two repeated measures levels of pre and post) of treatment would moderate pre- to post-intervention change. Results indicated significant differences on pre- and post-intervention scores for both groups of offenders on all measures. The analysis did not yield statistically significant differences between groups, demonstrating no additive benefits from the inclusion of four additional sessions, thus saving time and money for correctional programming and funding. This research supports the use of positive psychology in prison interventions. © The Author(s) 2014.

  11. Brightness enhancement of plasma ion source by utilizing anode spot for nano applications

    International Nuclear Information System (INIS)

    Park, Yeong-Shin; Lee, Yuna; Chung, Kyoung-Jae; Hwang, Y. S.; Kim, Yoon-Jae; Park, Man-Jin; Moon, Dae Won

    2012-01-01

    Anode spots are known as additional discharges on positively biased electrode immersed in plasmas. The anode spot plasma ion source (ASPIS) has been investigated as a high brightness ion source for nano applications such as focused ion beam (FIB) and nano medium energy ion scattering (nano-MEIS). The generation of anode spot is found to enhance brightness of ion beam since the anode spot increases plasma density near the extraction aperture. Brightness of the ASPIS has been estimated from measurement of emittance for total ion beam extracted through sub-mm aperture. The ASPIS is installed to the FIB system. Currents and diameters of the focused beams with/without anode spot are measured and compared. As the anode spot is turned on, the enhancement of beam current is observed at fixed diameter of the focused ion beam. Consequently, the brightness of the focused ion beam is enhanced as well. For argon ion beam, the maximum normalized brightness of 12 300 A/m 2 SrV is acquired. The ASPIS is applied to nano-MEIS as well. The ASPIS is found to increase the beam current density and the power efficiency of the ion source for nano-MEIS. From the present study, it is shown that the ASPIS can enhance the performance of devices for nano applications.

  12. Context Aware Handover Algorithms For Mobile Positioning Systems

    Directory of Open Access Journals (Sweden)

    Sazid Z. Khan

    2014-01-01

    Full Text Available Abstract: This work proposes context aware handover algorithms for mobile positioning systems. The algorithms perform handover among positioning systems based on important contextual factors related to position determination with efficient use of battery. The proposed solution which consists of the algorithms is implemented in the form of an Android application named Locate@nav6. The performance of the proposed solution was tested in selected experimental areas. The handover performance was compared with other existing location applications. The proposed solution performed correct handover among positioning systems in 95% of cases studied while two other applications performed correct handover in only 50% of cases studied. Battery usage of the proposed solution is less than one third of the battery usage of two other applications. The analysis of the positioning error of the applications demonstrated that, the proposed solution is able to reduce positioning error indirectly by handing over the task of positioning to an appropriate positioning system. This kept the average error of positioning below 42.1 meters for Locate@nav6 while the average error for two other applications namely Google Latitude and Malaysia maps was between 92.7 and 171.13 meters.

  13. Health Physics Positions Data Base

    International Nuclear Information System (INIS)

    Kerr, G.D.; Borges, T.; Stafford, R.S.; Lu, P.Y.; Carter, D.

    1992-05-01

    The Health Physics Positions (HPPOS) Data Base of the Nuclear Regulatory Commission (NRC) is a collection of summaries of NRC staff positions on a wide range of topics in radiation protection (health physics). The bases for the data base are 247 original documents in the form of letters, memoranda, and excerpts from technical reports. The HPPOS Data Base was developed by the NRC Headquarters and Regional Offices to help ensure uniformity in inspections, enforcement, and licensing actions

  14. Introduction to Positive Psychology in Rehabilitation

    Science.gov (United States)

    Chou, Chih-Chin; Chan, Fong; Phillips, Brian; Chan, Jacob Yui Chung

    2013-01-01

    Positive psychology has received increasing attention in rehabilitation counseling research and practice. The rehabilitation counseling philosophy shares a similar emphasis of personal assets and strengths, which provides a solid foundation for the integration of positive psychology into the professional practice of rehabilitation counseling. In…

  15. [Natural head position's reproducibility on photographs].

    Science.gov (United States)

    Eddo, Marie-Line; El Hayeck, Émilie; Hoyeck, Maha; Khoury, Élie; Ghoubril, Joseph

    2017-12-01

    The purpose of this study is to evaluate the reproducibility of natural head position with time on profile photographs. Our sample is composed of 96 students (20-30 years old) at the department of dentistry of Saint Joseph University in Beirut. Two profile photographs were taken in natural head position about a week apart. No significant differences were found between T0 and T1 (E = 1.065°). Many studies confirmed this reproducibility with time. Natural head position can be adopted as an orientation for profile photographs in orthodontics. © EDP Sciences, SFODF, 2017.

  16. Being an HIV-positive mother: meanings for HIV-positive women and for professional nursing staff

    OpenAIRE

    Monticelli, Marisa; Santos, Evanguelia Kotzias Atherino dos; Erdmann, Alacoque Lorenzini

    2007-01-01

    OBJECTIVES: To comprehend the meanings of being an HIV-positive mother for HIV-positive women and for professional nursing staff of shared in-patient maternity wards, and to identify similarities and contrasts present in these meanings. METHODS: This was a descriptive and comparative secondary analysis study of data from two previous larger studies conducted in Public Hospitals of the Greater Florianopolis Area, Santa Catarina, Brazil. Data was collected through observation and interviews. RE...

  17. Cryotherapy impairs knee joint position sense.

    Science.gov (United States)

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint. Georg Thieme Verlag KG Stuttgart.New York.

  18. What good are positive emotions for treatment? Trait positive emotionality predicts response to Cognitive Behavioral Therapy for anxiety.

    Science.gov (United States)

    Taylor, Charles T; Knapp, Sarah E; Bomyea, Jessica A; Ramsawh, Holly J; Paulus, Martin P; Stein, Murray B

    2017-06-01

    Cognitive behavioral therapy (CBT) is empirically supported for the treatment of anxiety disorders; however, not all individuals achieve recovery following CBT. Positive emotions serve a number of functions that theoretically should facilitate response to CBT - they promote flexible patterns of information processing and assimilation of new information, encourage approach-oriented behavior, and speed physiological recovery from negative emotions. We conducted a secondary analysis of an existing clinical trial dataset to test the a priori hypothesis that individual differences in trait positive emotions would predict CBT response for anxiety. Participants meeting diagnostic criteria for panic disorder (n = 28) or generalized anxiety disorder (n = 31) completed 10 weekly individual CBT sessions. Trait positive emotionality was assessed at pre-treatment, and severity of anxiety symptoms and associated impairment was assessed throughout treatment. Participants who reported a greater propensity to experience positive emotions at pre-treatment displayed the largest reduction in anxiety symptoms as well as fewer symptoms following treatment. Positive emotions remained a robust predictor of change in symptoms when controlling for baseline depression severity. Initial evidence supports the predictive value of trait positive emotions as a prognostic indicator for CBT outcome in a GAD and PD sample. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. An in vitro-identified high-affinity nucleosome-positioning signal is capable of transiently positioning a nucleosome in vivo

    Directory of Open Access Journals (Sweden)

    Gracey Lia E

    2010-07-01

    Full Text Available Abstract Background The physiological function of eukaryotic DNA occurs in the context of nucleosomal arrays that can expose or obscure defined segments of the genome. Certain DNA sequences are capable of strongly positioning a nucleosome in vitro, suggesting the possibility that favorable intrinsic signals might reproducibly structure chromatin segments. As high-throughput sequencing analyses of nucleosome coverage in vitro and in vivo have become possible, a vigorous debate has arisen over the degree to which intrinsic DNA:nucleosome affinities orchestrate the in vivo positions of nucleosomes, thereby controlling physical accessibility of specific sequences in DNA. Results We describe here the in vivo consequences of placing a synthetic high-affinity nucleosome-positioning signal, the 601 sequence, into a DNA plasmid vector in mice. Strikingly, the 601 sequence was sufficient to position nucleosomes during an early phase after introduction of the DNA into the mice (when the plasmid vector transgene was active. This positioning capability was transient, with a loss of strong positioning at a later time point when the transgenes had become silent. Conclusions These results demonstrate an ability of DNA sequences selected solely for nucleosome affinity to organize chromatin in vivo, and the ability of other mechanisms to overcome these interactions in a dynamic nuclear environment.

  20. UHV photoelectron x-ray beam position monitor

    International Nuclear Information System (INIS)

    Johnson, E.D.; Oversluizen, T.

    1989-01-01

    As part of our research program to develop viable beam position monitors for both the X-ray and VUV beamlines at the NSLS, we have constructed vertical photon beam position monitors which are presently mounted in two front-ends in the X-ray ring. These area-type detectors are located before the safety shutters and are, therefore, able to monitor the beam position even during injection. The features of this type of monitor which contribute to its long-term stability, position sensitivity, and immunity to horizontal beam motion have been examined and will be discussed. 6 refs., 4 figs

  1. Two-dimensional approach to relativistic positioning systems

    International Nuclear Information System (INIS)

    Coll, Bartolome; Ferrando, Joan Josep; Morales, Juan Antonio

    2006-01-01

    A relativistic positioning system is a physical realization of a coordinate system consisting in four clocks in arbitrary motion broadcasting their proper times. The basic elements of the relativistic positioning systems are presented in the two-dimensional case. This simplified approach allows to explain and to analyze the properties and interest of these new systems. The positioning system defined by geodesic emitters in flat metric is developed in detail. The information that the data generated by a relativistic positioning system give on the space-time metric interval is analyzed, and the interest of these results in gravimetry is pointed out

  2. Persistent positional nystagmus: a case of superior semicircular canal benign paroxysmal positional vertigo?

    Science.gov (United States)

    Heidenreich, Katherine D; Kerber, Kevin A; Carender, Wendy J; Basura, Gregory J; Telian, Steven A

    2011-08-01

    Involvement of the superior semicircular canal (SSC) in benign paroxysmal positional vertigo (BPPV) is rare. SSC BPPV is distinguished from the more common posterior semicircular canal (PSC) variant by the pattern of nystagmus triggered by the Dix-Hallpike position: down-beating torsional nystagmus in SSC BPPV versus up-beating torsional nystagmus in PSC BPPV. SSC BPPV may be readily treated at the bedside, which is a key component in excluding central causes of down-beating nystagmus. We present an unusual video case report believed to represent refractory SSC BPPV based on the pattern of nystagmus and the absence of any other central signs. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  3. Review of design technology of control rod position indicators

    International Nuclear Information System (INIS)

    Yu, Je Yong; Huh, Hyung; Kim, Ji Ho; Kim, Jong In; Chang, Moon Hee

    1999-10-01

    An integral reactor SMART is under development at KAERI. The design characteristics of SMART are radically different from those employer in currently operating loop type water reactors in Korea. The objective of this report is to review the design technology of position indicator, and to study the various sensors which can be used in rod position indicator. Design criteria that rod position indicator should satisfy are also examined. Following position indicators are reviewed in this report. 1. Digital positioning indicator (DRPI), 2. Reed switch type position indicator (RSPT), 3. Choke sensor type position indicator, 4. Ultrasonic sensor type position indicator, 5. Comparison of each position indicator. (author)

  4. Education positive approach: contributions to human development

    Directory of Open Access Journals (Sweden)

    Clara ROMERO PÉREZ

    2012-02-01

    Full Text Available This article analizes the current theoretical perspectives underlying educational proposals aimed at promoting the positive development of the people. Firstly we show the most important characteristics of the positive approach. Then, we focus on the positive concept of the inner and its relation to eudaimonia, self-care and emotional selfgovernance. Thirdly, with reference to the contributions of Positive Psychology and Prevention Science we examine the two points of view –hedonic and eudaemonic– from which different pedagogical approaches are based and focus towards education for the welfare, social-emotional development and educational character. We conclude that, despite the lack of practical knowledge about happiness and the art of living, a positive education oriented to the human construction processes must promote both emotional and social skills such as feelings and moral responsibilities for the optimal development of human being.

  5. Prioritizing Positivity: An Effective Approach to Pursuing Happiness?

    Science.gov (United States)

    Catalino, Lahnna I.; Algoe, Sara B.; Fredrickson, Barbara L.

    2017-01-01

    A decade of research reveals the benefits of positive emotions for mental and physical health; however, recent empirical work suggests the explicit pursuit of happiness may backfire. The present study hypothesized that the pursuit of happiness is not inherently self-defeating; in particular, individuals who seek positivity, as exemplified by how they make decisions about how to organize their day-to-day lives, may be happier. This individual difference is labeled prioritizing positivity. In a community sample of young to older adults (N = 233), prioritizing positivity predicted a host of well-being outcomes (positive emotions, depressive symptomology). In addition, people high in prioritizing positivity have greater resources, and these links are explained by more frequent experiences of positive emotions. In sum, the present study suggests that seeking happiness, although a delicate art, may be a worthwhile pursuit. PMID:25401290

  6. Tracking control mechanisms for positioning automatic CRD exchanger

    International Nuclear Information System (INIS)

    Koizumi, Akira; Takada, Satoshi.

    1984-01-01

    Purpose: To enable completely automatic positioning for the automatic CRD (control rod drives) exchanger, as well as shorten the time for the exchanging operation and save the operator's labour. Constitution: Images of a target attached to the lower flange face of CRD are picked up by a fiber scope mounted to a mounting head. The images are converted through I.T.V. into electrical signals, passed through a cable and then sent to a pattern recognition mechanism. The position for the images of the target is calculated and the calculated position is sent to a drive control section, where the position for the images of the target is compared with a reference position for the images (exactly aligned position) and the moving amount of the mounting head is calculated to move the driving section and thereby complete the positioning. (Kawakami, Y.)

  7. STUDY OF WINES POSITIONING ON THE ROMANIAN MARKET

    Directory of Open Access Journals (Sweden)

    Alex GAVRILESCU

    2011-01-01

    Full Text Available In this paper, I have done a research on the positioning of Romanian wines. The positioning is a necessary approach of brands to have a privileged position in the minds of consumers. In front of the keen foreign competition, the Romanian wine brands must assert a new identity to match the Romanian client's current lifestyle. The main objective of the research is the identification of the Romanian wine brand positioning. To achieve the objective of the research I have conducted a market research. The study was conducted on a sample of 100 respondents, consumers of Romanian wines. In the study, I have focused on a number of elements necessary for obtaining the positioning maps. Thus I tested the assisted and unassisted recognition of vineyards, the vineyards positioning depending on internal and international recognition and tradition / reputation, the vineyards positioning depending on the internal and international recognition and price, the vineyards positioning depending on sweet, red and light wines and on strong and dry wines. The positioning strategy will determine, on the one hand, the efficiency of the marketing activity at the level of consumer segment by obtaining a better image due to the high satisfaction of the specific needs, and on the other hand, the differentiation will enable to the company to gain competitive advantages, hence substantially increased profits. The theoretical contribution of this paper is to clarify the issues of positioning and to emphasize its importance. The practical contribution refers to the positioning of wines brands, which can be a model of reflection for each of the analyzed vineyards.

  8. Driving and positioning arrangement for radiography

    International Nuclear Information System (INIS)

    Ingham, W.E.; Williams, A.M.

    1980-01-01

    Details of the design of novel equipment for use in computerised axial tomographic scanning are given. The apparatus enables accurate driving and positioning of the tomographic apparatus while the patient retains a horizontal position. Furthermore, the movement is effected automatically and in a controllable manner. (UK)

  9. Green positive guidance and green positive life counseling for decent work and decent lives:Some empirical results

    Directory of Open Access Journals (Sweden)

    Annamaria eDi Fabio

    2016-03-01

    Full Text Available This article discusses green positive guidance and green positive life counseling for decent work and decent lives. From a green guidance perspective, the connectedness to nature construct is important both in terms of the meaning of work and life construction. The study discussed in this article analyzed the relationship between empathy and connectedness to nature, controlling for the effects of fluid intelligence and personality traits. In this connection, the Advanced Progressive Matrices (APM, the Big Five Questionnaire (BFQ, and the Interpersonal Reactivity Index (IRI were administered to 144 Italian high school students. The study revealed that connecteness to nature was not associated with fluid intelligence and was only moderately associated with personality traits. It was empathy that showed the highest association with connectedness to nature. The results open new opportunities for future research and interventions in green positive guidance/life counseling and green positive decent work.

  10. Couples with dementia: Positioning the 'we'.

    Science.gov (United States)

    Hydén, Lars-Christer; Nilsson, Elin

    2015-11-01

    The aim of this article is to investigate how spouses in couples with dementia position themselves in relation to each other by analysing their use of pronouns, especially the we. The study uses joint interviews with 11 couples. Based on a quantitative analysis of pronoun use, it is argued that the pronoun we is used by all the spouses; however, it is used less frequently by the spouses with dementia in comparison with healthy spouses. A qualitative analysis of the use of the pronoun we shows that the spouses position, experience and consider themselves as a couple and that they position and experience themselves as individuals in relation to the couple. One of the challenges for couples with dementia is to be able to retain a we in face of the progression of the dementia disease. By positioning themselves in various ways, the spouses establish and negotiate quite a complex and emotionally charged web of relationships. © The Author(s) 2013.

  11. Person-centred positive emotions, object-centred negative emotions: 2-year-olds generalize negative but not positive emotions across individuals.

    Science.gov (United States)

    Vaish, Amrisha; Grossmann, Tobias; Woodward, Amanda

    2015-09-01

    Prior work suggests that young children do not generalize others' preferences to new individuals. We hypothesized (following Vaish et al., 2008, Psychol. Bull., 134, 383-403) that this may only hold for positive emotions, which inform the child about the person's attitude towards the object but not about the positivity of the object itself. It may not hold for negative emotions, which additionally inform the child about the negativity of the object itself. Two-year-old children saw one individual (the emoter) emoting positively or negatively towards one and neutrally towards a second novel object. When a second individual then requested an object, children generalized the emoter's negative but not her positive emotion to the second individual. Children thus draw different inferences from others' positive versus negative emotions: Whereas they view others' positive emotions as person centred, they may view others' negative emotions as object centred and thus generalizable across people. The results are discussed with relation to the functions and implications of the negativity bias. © 2015 The British Psychological Society.

  12. Sample positioning effects in x-ray spectrometry

    International Nuclear Information System (INIS)

    Carpenter, D.

    Instrument error due to variation in sample position in a crystal x-ray spectrometer can easily exceed the total instrumental error. Lack of reproducibility in sample position in the x-ray optics is the single largest source of system error. The factors that account for sample positioning error are described, and many of the details of flat crystal x-ray optics are discussed

  13. How social position of origin relates to intelligence and level of education when adjusting for attained social position.

    Science.gov (United States)

    Sorjonen, Kimmo; Hemmingsson, Tomas; Lundin, Andreas; Melin, Bo

    2011-06-01

    Intelligence and its relationship to achievement is a classical question within psychology. In accordance with earlier British studies, the present study, based on conscription data and follow-ups for Swedish men born 1949-51 (N = 36,156), found that when adjusting for attained social position, people with a high social position of origin tend to have higher intelligence and level of education than people with a lower social position of origin. These results could be seen to contradict the claim that more merit, at least when operationalized as intelligence or education, is required from people with a low social position of origin in order to attain a certain social level. © 2011 The Authors. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.

  14. Positive Peer Culture with German Youth

    Science.gov (United States)

    Steinebach, Christoph; Steinebach, Ursula

    2009-01-01

    Children and youth develop the ability to surmount difficult life challenges through a combination of external supports and internal strengths. Positive peers can contribute substantially to growth in resilient coping and problem-solving skills. Positive Peer Culture (PPC) programs are designed to strengthen supportive social bonds, competence,…

  15. 14 CFR 99.15 - Position reports.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Position reports. 99.15 Section 99.15 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.15 Position reports. (a) The...

  16. 30 CFR 57.7052 - Drilling positions.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drilling positions. 57.7052 Section 57.7052... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7052 Drilling positions. Persons shall not drill...

  17. Serial Position Functions in General Knowledge

    Science.gov (United States)

    Kelley, Matthew R.; Neath, Ian; Surprenant, Aimée M.

    2015-01-01

    Serial position functions with marked primacy and recency effects are ubiquitous in episodic memory tasks. The demonstrations reported here explored whether bow-shaped serial position functions would be observed when people ordered exemplars from various categories along a specified dimension. The categories and dimensions were: actors and age;…

  18. Data analysis of photon beam position at PLS-II

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J.; Shin, S., E-mail: tlssh@postech.ac.kr; Huang, Jung-Yun; Kim, D.; Kim, C.; Kim, Ilyou; Lee, T.-Y.; Park, C.-D.; Kim, K. R. [Pohang Accelerator Laboratory, Pohang, Kyungbuk 790-834 (Korea, Republic of); Cho, Moohyun [Department of Physics, POSTECH, Pohang, Kyungbuk 790-834 (Korea, Republic of)

    2016-07-27

    In the third generation light source, photon beam position stability is critical issue on user experiment. Generally photon beam position monitors have been developed for the detection of the real photon beam position and the position is controlled by feedback system in order to keep the reference photon beam position. In the PLS-II, photon beam position stability for front end of particular beam line, in which photon beam position monitor is installed, has been obtained less than rms 1μm for user service period. Nevertheless, detail analysis for photon beam position data in order to demonstrate the performance of photon beam position monitor is necessary, since it can be suffers from various unknown noises. (for instance, a back ground contamination due to upstream or downstream dipole radiation, undulator gap dependence, etc.) In this paper, we will describe the start to end study for photon beam position stability and the Singular Value Decomposition (SVD) analysis to demonstrate the reliability on photon beam position data.

  19. Fractional-order positive position feedback compensator for active vibration control of a smart composite plate

    Science.gov (United States)

    Marinangeli, L.; Alijani, F.; HosseinNia, S. Hassan

    2018-01-01

    In this paper, Active Vibration Control (AVC) of a rectangular carbon fibre composite plate with free edges is presented. The plate is subjected to out-of-plane excitation by a modal vibration exciter and controlled by Macro Fibre Composite (MFC) transducers. Vibration measurements are performed by using a Laser Doppler Vibrometer (LDV) system. A fractional-order Positive Position Feedback (PPF) compensator is proposed, implemented and compared to the standard integer-order PPF. MFC actuator and sensor are positioned on the plate based on maximal modal strain criterion, so as to control the second natural mode of the plate. Both integer and fractional-order PPF allowed for the effective control of the second mode of vibration. However, the newly proposed fractional-order controller is found to be more efficient in achieving the same performance with less actuation voltage. Moreover, it shows promising performance in reducing spillover effect due to uncontrolled modes.

  20. Predictors for benign paroxysmal positional vertigo with positive Dix–Hallpike test

    Directory of Open Access Journals (Sweden)

    Noda K

    2011-12-01

    Full Text Available Kazutaka Noda, Masatomi Ikusaka, Yoshiyuki Ohira, Toshihiko Takada, Tomoko TsukamotoDepartment of General Medicine, Chiba University Hospital, Chiba, JapanObjective: Patient medical history is important for making a diagnosis of causes of dizziness, but there have been no studies on the diagnostic value of individual items in the history. This study was performed to identify and validate useful questions for suspecting a diagnosis of benign paroxysmal positional vertigo (BPPV.Methods: Construction and validation of a disease prediction model was performed at the outpatient clinic in the Department of General Medicine of Chiba University Hospital. Patients with dizziness were enrolled (145 patients for construction of the disease prediction model and 61 patients for its validation. This study targeted BPPV of the posterior semicircular canals only with a positive Dix–Hallpike test (DHT + BPPV to avoid diagnostic ambiguity. Binomial logistic regression analysis was performed to identify the items that were useful for diagnosis or exclusion of DHT + BPPV.Results: Twelve patients from the derivation set and six patients from the validation set had DHT + BPPV. Binomial logistic regression analysis selected a "duration of dizziness ≤15 seconds" and "onset when turning over in bed" as independent predictors of DHT + BPPV with an odds ratio (95% confidence interval of 4.36 (1.18–16.19 and 10.17 (2.49–41.63, respectively. Affirmative answers to both questions yielded a likelihood ratio of 6.81 (5.11–9.10 for diagnosis of DHT + BPPV, while negative answers to both had a likelihood ratio of 0.19 (0.08–0.47.Conclusion: A "duration of dizziness ≤15 seconds" and "onset when turning over in bed" were the two most important questions among various historical features of BPPV.Keywords: benign paroxysmal positional vertigo, likelihood ratio, diagnosis, screening, prediction rules

  1. Positive autobiographical memory retrieval reduces temporal discounting

    Science.gov (United States)

    Lempert, Karolina M; Speer, Megan E; Delgado, Mauricio R

    2017-01-01

    Abstract People generally prefer rewards sooner rather than later. This phenomenon, temporal discounting, underlies many societal problems, including addiction and obesity. One way to reduce temporal discounting is to imagine positive future experiences. Since there is overlap in the neural circuitry associated with imagining future experiences and remembering past events, here we investigate whether recalling positive memories can also promote more patient choice. We found that participants were more patient after retrieving positive autobiographical memories, but not when they recalled negative memories. Moreover, individuals were more impulsive after imagining novel positive scenes that were not related to their memories, showing that positive imagery alone does not drive this effect. Activity in the striatum and temporo parietal junction during memory retrieval predicted more patient choice, suggesting that to the extent that memory recall is rewarding and involves perspective-taking, it influences decision-making. Furthermore, representational similarity in the ventromedial prefrontal cortex between memory recall and decision phases correlated with the behavioral effect across participants. Thus, we have identified a novel manipulation for reducing temporal discounting—remembering the positive past—and have begun to characterize the psychological and neural mechanisms behind it. PMID:28655195

  2. Beam position monitor system for storage rings

    International Nuclear Information System (INIS)

    Nakamura, M.; Hinkson, J.A.

    1985-05-01

    Beam position monitors (BPM) for synchrotron light storage rings usually consist of beam pickup electrodes, coaxial relays and a narrowband receiver. While accurate, these systems are slow and of limited use in the commissioning of an accelerator. A beam position monitor is described which is intended to be a principal diagnostic during debug and routine running of a storage ring. It is capable of measuring the position of a single bunch on the first or nth orbit to an accuracy of a few percent. Stored beam position is more accurately measured with averaging techniques. Beam position changes can be studied in a bandwidth from DC to a few MHz. The beam monitor electronics consist of a separate amplification, detection, and sampling channel for each beam pickup electrode. Fast switches in each channel permit selection of the nth turn for measurement (single bunch mode). A calibration pulse is injected into each channel after beam measurement to permit gain offsets to be measured and removed from the final data. While initially more costly than the usual beam position monitor system, this sytem will pay for itself in reduced storage ring debug and trouble shooting time. 5 refs., 5 figs

  3. Nano-Scale Positioning Design with Piezoelectric Materials

    Directory of Open Access Journals (Sweden)

    Yung Yue Chen

    2017-12-01

    Full Text Available Piezoelectric materials naturally possess high potential to deliver nano-scale positioning resolution; hence, they are adopted in a variety of engineering applications widely. Unfortunately, unacceptable positioning errors always appear because of the natural hysteresis effect of the piezoelectric materials. This natural property must be mitigated in practical applications. For solving this drawback, a nonlinear positioning design is proposed in this article. This nonlinear positioning design of piezoelectric materials is realized by the following four steps: 1. The famous Bouc–Wen model is utilized to present the input and output behaviors of piezoelectric materials; 2. System parameters of the Bouc–Wen model that describe the characteristics of piezoelectric materials are simultaneously identified with the particle swam optimization method; 3. Stability verification for the identified Bouc–Wen model; 4. A nonlinear feedback linearization control design is derived for the nano-scale positioning design of the piezoelectric material, mathematically. One important contribution of this investigation is that the positioning error between the output displacement of the controlled piezoelectric materials and the desired trajectory in nano-scale level can be proven to converge to zero asymptotically, under the effect of the hysteresis.

  4. Positive autobiographical memory retrieval reduces temporal discounting.

    Science.gov (United States)

    Lempert, Karolina M; Speer, Megan E; Delgado, Mauricio R; Phelps, Elizabeth A

    2017-10-01

    People generally prefer rewards sooner rather than later. This phenomenon, temporal discounting, underlies many societal problems, including addiction and obesity. One way to reduce temporal discounting is to imagine positive future experiences. Since there is overlap in the neural circuitry associated with imagining future experiences and remembering past events, here we investigate whether recalling positive memories can also promote more patient choice. We found that participants were more patient after retrieving positive autobiographical memories, but not when they recalled negative memories. Moreover, individuals were more impulsive after imagining novel positive scenes that were not related to their memories, showing that positive imagery alone does not drive this effect. Activity in the striatum and temporo parietal junction during memory retrieval predicted more patient choice, suggesting that to the extent that memory recall is rewarding and involves perspective-taking, it influences decision-making. Furthermore, representational similarity in the ventromedial prefrontal cortex between memory recall and decision phases correlated with the behavioral effect across participants. Thus, we have identified a novel manipulation for reducing temporal discounting-remembering the positive past-and have begun to characterize the psychological and neural mechanisms behind it. © The Author (2017). Published by Oxford University Press.

  5. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  6. Consequences of a false-positive mammography result

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Bæksted, Christina; Vejborg, Ilse

    2016-01-01

    group used anxiolytic and antidepressant drugs. There was no difference in use of beta blockers. Hormone therapy was used more frequently by the false-positive, 36.6% versus 28.7%. The proportion of women using anxiolytic and antidepressant drugs increased with 19% from the before to the after period...... in the false-positive group, and with 16% in the normal group, resulting in an RRR of 1.02 (95% CI 0.92-1.14). RRR was 1.03 for beta blockers, 0.97 for hormone therapy. Conclusion(s): Drugs used to mitigate mood disorders were used more frequently by women with false-positive than by women with normal......Background: Previous research showed women experiencing false-positive mammograms to have greater anxiety about breast cancer than women with normal mammograms. To elucidate psychological effects of false-positive mammograms, we studied impact on drug intake.  Methods: We calculated the ratio...

  7. Local systematic differences in 2MASS positions

    Science.gov (United States)

    Bustos Fierro, I. H.; Calderón, J. H.

    2018-01-01

    We have found that positions in the 2MASS All-sky Catalog of Point Sources show local systematic differences with characteristic length-scales of ˜ 5 to ˜ 8 arcminutes when compared with several catalogs. We have observed that when 2MASS positions are used in the computation of proper motions, the mentioned systematic differences cause systematic errors in the resulting proper motions. We have developed a method to locally rectify 2MASS with respect to UCAC4 in order to diminish the systematic differences between these catalogs. The rectified 2MASS catalog with the proposed method can be regarded as an extension of UCAC4 for astrometry with accuracy ˜ 90 mas in its positions, with negligible systematic errors. Also we show that the use of these rectified positions removes the observed systematic pattern in proper motions derived from original 2MASS positions.

  8. Noise in position measurement by centroid calculation

    International Nuclear Information System (INIS)

    Volkov, P.

    1996-01-01

    The position of a particle trajectory in a gaseous (or semiconductor) detector can be measured by calculating the centroid of the induced charge on the cathode plane. The charge amplifiers attached to each cathode strip introduce noise which is added to the signal. This noise broadens the position resolution line. Our article gives an analytical tool to estimate the resolution broadening due to the noise per strip and the number of strips involved in the centroid calculation. It is shown that the position resolution increases faster than the square root of the number of strips involved. We also consider the consequence of added interstrip capacitors, intended to diminish the differential nonlinearity. It is shown that the position error increases slower than linearly with the interstrip capacities, due to the cancellation of correlated noise. The estimation we give, can be applied to calculations of position broadening other than the centroid finding. (orig.)

  9. GPS Software Packages Deliver Positioning Solutions

    Science.gov (United States)

    2010-01-01

    "To determine a spacecraft s position, the Jet Propulsion Laboratory (JPL) developed an innovative software program called the GPS (global positioning system)-Inferred Positioning System and Orbit Analysis Simulation Software, abbreviated as GIPSY-OASIS, and also developed Real-Time GIPSY (RTG) for certain time-critical applications. First featured in Spinoff 1999, JPL has released hundreds of licenses for GIPSY and RTG, including to Longmont, Colorado-based DigitalGlobe. Using the technology, DigitalGlobe produces satellite imagery with highly precise latitude and longitude coordinates and then supplies it for uses within defense and intelligence, civil agencies, mapping and analysis, environmental monitoring, oil and gas exploration, infrastructure management, Internet portals, and navigation technology."

  10. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...... position displays complex behavior with regions of positive and negative interference. By analyzing the scattered light intensity as a function of the axial position of the trapped sphere, we propose a simple method to increase the sensitivity and control the linear range of axial position detection....

  11. College Students' Positivity toward Teen Mothers

    Science.gov (United States)

    Eshbaugh, Elaine M.

    2011-01-01

    Although teen pregnancy and parenthood are more visible in society than in the past, teen mothers are often stereotyped and stigmatized. The study examined positivity toward teen mothers among college students (N = 316) at a midwestern university. Although students responded positively to some items regarding teen mothers, other statements showed…

  12. Transformation of gram positive bacteria by sonoporation

    Science.gov (United States)

    Yang, Yunfeng; Li, Yongchao

    2014-03-11

    The present invention provides a sonoporation-based method that can be universally applied for delivery of compounds into Gram positive bacteria. Gram positive bacteria which can be transformed by sonoporation include, for example, Bacillus, Streptococcus, Acetobacterium, and Clostridium. Compounds which can be delivered into Gram positive bacteria via sonoporation include nucleic acids (DNA or RNA), proteins, lipids, carbohydrates, viruses, small organic and inorganic molecules, and nano-particles.

  13. Position reconstruction in LUX

    Science.gov (United States)

    Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Druszkiewicz, E.; Edwards, B. N.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Genovesi, J.; Ghag, C.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.

    2018-02-01

    The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including 83mKr (releasing a total energy of 41.5 keV) and 3H (β- with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV) . Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of σ = 0.82 cm and σ = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies ~0.25 keV and ~10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.

  14. Precise GNSS Positioning Using Smart Devices

    Directory of Open Access Journals (Sweden)

    Eugenio Realini

    2017-10-01

    Full Text Available The recent access to GNSS (Global Navigation Satellite System phase observations on smart devices, enabled by Google through its Android operating system, opens the possibility to apply precise positioning techniques using off-the-shelf, mass-market devices. The target of this work is to evaluate whether this is feasible, and which positioning accuracy can be achieved by relative positioning of the smart device with respect to a base station. Positioning of a Google/HTC Nexus 9 tablet was performed by means of batch least-squares adjustment of L1 phase double-differenced observations, using the open source goGPS software, over baselines ranging from approximately 10 m to 8 km, with respect to both physical (geodetic or low-cost and virtual base stations. The same positioning procedure was applied also to a co-located u-blox low-cost receiver, to compare the performance between the receiver and antenna embedded in the Nexus 9 and a standard low-cost single-frequency receiver with external patch antenna. The results demonstrate that with a smart device providing raw GNSS phase observations, like the Nexus 9, it is possible to reach decimeter-level accuracy through rapid-static surveys, without phase ambiguity resolution. It is expected that sub-centimeter accuracy could be achieved, as demonstrated for the u-blox case, if integer phase ambiguities were correctly resolved.

  15. Precise GNSS Positioning Using Smart Devices.

    Science.gov (United States)

    Realini, Eugenio; Caldera, Stefano; Pertusini, Lisa; Sampietro, Daniele

    2017-10-24

    The recent access to GNSS (Global Navigation Satellite System) phase observations on smart devices, enabled by Google through its Android operating system, opens the possibility to apply precise positioning techniques using off-the-shelf, mass-market devices. The target of this work is to evaluate whether this is feasible, and which positioning accuracy can be achieved by relative positioning of the smart device with respect to a base station. Positioning of a Google/HTC Nexus 9 tablet was performed by means of batch least-squares adjustment of L1 phase double-differenced observations, using the open source goGPS software, over baselines ranging from approximately 10 m to 8 km, with respect to both physical (geodetic or low-cost) and virtual base stations. The same positioning procedure was applied also to a co-located u-blox low-cost receiver, to compare the performance between the receiver and antenna embedded in the Nexus 9 and a standard low-cost single-frequency receiver with external patch antenna. The results demonstrate that with a smart device providing raw GNSS phase observations, like the Nexus 9, it is possible to reach decimeter-level accuracy through rapid-static surveys, without phase ambiguity resolution. It is expected that sub-centimeter accuracy could be achieved, as demonstrated for the u-blox case, if integer phase ambiguities were correctly resolved.

  16. Downsizing of health-system pharmacist positions.

    Science.gov (United States)

    Kahaleh, A A; Siganga, W; Holiday-Goodman, M; Lively, B T

    1998-11-15

    The effects of downsizing on institutional pharmacists were studied. A national mail survey was sent to a random sample of 533 members of ASHP in January 1997. The questionnaire was designed to determine (1) the influence of selected factors on the downsizing of pharmacist positions and (2) pharmacists' attitudes about downsizing. A total of 256 usable questionnaires were received, for a net response rate of 48%. Forty-four pharmacists, or 17%, had personally been affected by downsizing. Sixty-one percent of the pharmacists affected by downsizing had had administrative positions. After downsizing, only 32% of the pharmacists had an administrative position. Most of the pharmacists were currently employed. Thirty-five (79%) described their current job responsibilities as substantially changed. Two thirds made the same salaries or higher salaries. Pharmacists who had been downsized rated mergers, the impact of managed care, and the profit motive as the most influential causes of downsizing of pharmacist positions. The three most common negative comments about the impact of downsizing cited reduction in the quality of patient care, increased stress, and lowered morale. Most of the pharmacists believed that communication skills, education, cross-training, and clinical skills are keys to surviving downsizing. Most pharmacists whose positions were downsized said they went on to jobs with similar or higher salaries and substantially different responsibilities.

  17. Open table-top device positioning technique to reduce small bowel obstruction. Positioning accuracy and impact on conformal radiation therapy techniques

    International Nuclear Information System (INIS)

    Rudat, V.; Flentje, M.; Engenhart, R.; Metzger, M.; Wannenmacher, M.

    1995-01-01

    The immobilization error of patients positioned on the opern table-top device in prone prosition as well as the movement of the small bowel out of the pelvis by this positioning technique was determined. The positioning error is of special importance for the 3-dimensional treatment planning for conformal radiotherapy. The positioning error was determined by superposing 106 portal films with the corresponding simultor films from 21 patients with carcinoma of the rectum who received 3D-planned conformal radiotherapy (o-field technique with irregular blocks). The movement of the small bowel out of the pelvis was studied by comparing simulator films after barium swallow in supine and open table-top position as well with 3D-treatment plans of the same patient in both positions in 3 cases. The positioning error along the medio-lateral, dorso-ventral und cranio-caudal axis was 1.4/-0.6/1.8 mm and the standard deviation 4.4/6.8/6.3 mm, respectively. In comparison to the supine position more rotation errors in the sagittal view were observed (37% and 9% respectively) with a media of 5.1 . Six out of 22 patients showed no adhesions of the small bowel and a complete movement out of the tratment field was achieved. 14 out of 16 Patients with adhesions revealed a partial movement of the small bowel out of the treatment field. Comparing 3D-treatment plans in both positions again demonstrated a marked reduction of the irradiated small bowel volume with the use of the open table-top decive. (orig.) [de

  18. [Are positive illusions adaptive?: self- and other-rating].

    Science.gov (United States)

    Toyama, Miki

    2008-08-01

    The present study investigated the relationship between children's overly positive self-perceptions of their own social competence and mental health. Elementary school students (grades fourth to sixth, n=331) and their homeroom teachers (n=9) participated in the study. The positive illusion was measured by the difference between the self-rating and the other (homeroom teachers) -rating. And, the index of mental health was administered in both self-rating and other (homeroom teachers and same-sex classmates) -rating forms. Positive illusions about children's social competence were positively related to self-ratings of mental health. However, the present study also found detrimental effects of such positive illusions. Children with excessively positive views of their social competence were viewed by teachers and same-sex classmates as significantly more aggressive than those children who showed more evidence of self-devaluation. In addition, children with overly positive self-perceptions were not as accepted by same-sex classmates.

  19. Optically directed molecular transport and 3D isoelectric positioning of amphoteric biomolecules

    International Nuclear Information System (INIS)

    Hafeman, Dean G.; Harkins, James B.; Witkowski, Charles E. II; Lewis, Nathan S.; Brown, Gilbert M.; Warmack, Robert J. Bruce; Thundat, Thomas George

    2006-01-01

    We demonstrate the formation of charged molecular packets and their transport within optically created electrical force-field traps in a pH-buffered electrolyte. We call this process photoelectrophoretic localization and transport (PELT). The electrolyte is in contact with a photoconductive semiconductor electrode and a counterelectrode that are connected through an external circuit. A light beam directed to coordinates on the photoconductive electrode surface produces a photocurrent within the circuit and electrolyte. Within the electrolyte, the photocurrent creates localized force-field traps centered at the illuminated coordinates. Charged molecules, including polypeptides and proteins, electrophoretically accumulate into the traps and subsequently can be transported in the electrolyte by moving the traps over the photoconductive electrode in response to movement of the light beam. The molecules in a single trap can be divided into aliquots, and the aliquots can be directed along multiple routes simultaneously by using multiple light beams. This photoelectrophoretic transport of charged molecules by PELT resembles the electrostatic transport of electrons within force-field wells of solid-state charge-coupled devices. The molecules, however, travel in a liquid electrolyte rather than a solid. Furthermore, we have used PELT to position amphoteric biomolecules in three dimensions. A 3D pH gradient was created in an electrolyte medium by controlling the illumination position on a photoconductive anode where protons were generated electrolytically. Photoelectrophoretic transport of amphoteric molecules through the pH gradient resulted in accumulation of the molecules at their apparent 3D isoelectric coordinates in the medium.

  20. Positive sliding mode control for blood glucose regulation

    Science.gov (United States)

    Menani, Karima; Mohammadridha, Taghreed; Magdelaine, Nicolas; Abdelaziz, Mourad; Moog, Claude H.

    2017-11-01

    Biological systems involving positive variables as concentrations are some examples of so-called positive systems. This is the case of the glycemia-insulinemia system considered in this paper. To cope with these physical constraints, it is shown that a positive sliding mode control (SMC) can be designed for glycemia regulation. The largest positive invariant set (PIS) is obtained for the insulinemia subsystem in open and closed loop. The existence of a positive SMC for glycemia regulation is shown here for the first time. Necessary conditions to design the sliding surface and the discontinuity gain are derived to guarantee a positive SMC for the insulin dynamics. SMC is designed to be positive everywhere in the largest closed-loop PIS of plasma insulin system. Two-stage SMC is employed; the last stage SMC2 block uses the glycemia error to design the desired insulin trajectory. Then the plasma insulin state is forced to track the reference via SMC1. The resulting desired insulin trajectory is the required virtual control input of the glycemia system to eliminate blood glucose (BG) error. The positive control is tested in silico on type-1 diabetic patients model derived from real-life clinical data.

  1. A Positive Stigma for Child Labor?

    Science.gov (United States)

    Patrinos, Harry Anthony; Shafiq, M. Najeeb

    2008-01-01

    We introduce a simple empirical model that assumes a positive stigma (or norm) towards child labor that is common in some developing countries. We then illustrate our positive stigma model using data from Guatemala. Controlling for several child- and household-level characteristics, we use two instruments for measuring stigma: a child's indigenous…

  2. Efficiency of the modified Sims maternal position in the rotation of persistent occiput posterior position during labor: A randomized clinical trial.

    Science.gov (United States)

    Bueno-Lopez, Vanessa; Fuentelsaz-Gallego, Carmen; Casellas-Caro, Manel; Falgueras-Serrano, Ana Maria; Crespo-Berros, Silvia; Silvano-Cocinero, Ana Maria; Alcaine-Guisado, Carolina; Zamoro Fuentes, Manuela; Carreras, Elena; Terré-Rull, Carmen

    2018-03-14

    Fetal occiput posterior position in labor is associated with more painful and prolonged labor, and an increase in both maternal and fetal morbidity. The aim of this study is to assess whether the modified Sims position on the side of the fetal spine increases the rotation to occiput anterior position in women with epidural analgesia and a fetus in persistent occiput posterior (POP) position. This is an open, randomized controlled, clinical trial. One hundred and twenty women in labor with fetuses in POP position were included. The diagnosis was performed through digital vaginal examination and confirmed with an ultrasound scan. Women were randomized into the free position group or the modified Sims on the side of the fetal spine. The primary outcome was rotation to occiput anterior, and secondary outcomes were type of delivery, postpartum perineal condition, perinatal results, and maternal satisfaction. In pregnant women undergoing labor in the Sims position, fetuses in POP rotated to occiput anterior in 50.8% of cases, whilst in the free position group, the rotation occurred in 21.7% (P = .001). The rate of vaginal deliveries was higher in the Sims group compared with the free position group (84.7% vs 68.3%, P = .035). The modified Sims position is a maternal posture intervention efficient in POP rotation, which decreases cesarean delivery rate. It is a simple and noninvasive intervention, reproducible, and well tolerated by pregnant women. © 2018 Wiley Periodicals, Inc.

  3. Polymer nanoimprinting using an anodized aluminum mold for structural coloration

    Science.gov (United States)

    Kikuchi, Tatsuya; Nishinaga, Osamu; Natsui, Shungo; Suzuki, Ryosuke O.

    2015-06-01

    Polymer nanoimprinting of submicrometer-scale dimple arrays with structural coloration was demonstrated. Highly ordered aluminum dimple arrays measuring 530-670 nm in diameter were formed on an aluminum substrate via etidronic acid anodizing at 210-270 V and subsequent anodic oxide dissolution. The nanostructured aluminum surface led to bright structural coloration with a rainbow spectrum, and the reflected wavelength strongly depends on the angle of the specimen and the period of the dimple array. The reflection peak shifts gradually with the dimple diameter toward longer wavelength, reaching 800 nm in wavelength at 670 nm in diameter. The shape of the aluminum dimple arrays were successfully transferred to a mercapto-ester ultra-violet curable polymer via self-assembled monolayer coating and polymer replications using a nanoimprinting technique. The nanostructured polymer surfaces with positively and negatively shaped dimple arrays also exhibited structural coloration based on the periodic nanostructure, and reflected light mostly in the visible region, 400-800 nm. This nanostructuring with structural coloration can be easily realized by simple techniques such as anodizing, SAM coating, and nanoimprinting.

  4. Anatomical Position of Mental foramen: a Review

    Directory of Open Access Journals (Sweden)

    Vinit Aher

    2012-01-01

    Full Text Available Mental foramen is a key factor in many of the surgical as well as clinical procedures in routine clinical practice. The variations of mental foramen with respect to position, size and number dose significantly alter the clinical implications of various intraoral treatments. The accurate knowledge of the mental nerve and its position helps the clinician for delivering local anesthesia effectively also placement of implants and dentures intraorally to replace missing teeth is important in prosthetic point of view. While doing the surgical procedures in this region the position of mental nerve and its foramen is of importance to avoid intraoperative neurovascular damage and to avoid postoperative neurosensory disturbances. The ethnic and racial variations are seen in the position of mental foramen, although a gender variation in same population has not been seen. Thus the knowledge of the position of mental nerve is important for day to day clinical practice of dentistry.

  5. Positioning as a Part of Political Marketing

    Directory of Open Access Journals (Sweden)

    Natalia Liutko

    2015-11-01

    Full Text Available The political subject is defined as the consumer of goods in the form of political power, political ideas, political leaders, and parties. Political marketing is understood as the identification of political relations and processes with different forms of market exchange and the process of electoral choice as a specific market (the act of purchase and sale. The concept of political positioning appeared as the result of relevant categories of commercial research in the political sphere. Political positioning should be considered as the process of political communication aimed at acquiring by political actor his position in political marketing. It is the most difficult type of political and communication strategic campaigns. This approach allows the candidate (party to compare his image with electorate’s views of desired (acceptable candidate, political party; compare his image with the image of an opponent; explore the pros and cons of alternative positions; and choose those the most advantageous position for a candidate (party.

  6. Submicron position-sensitive detector

    Energy Technology Data Exchange (ETDEWEB)

    Pugatch, V M; Rosenfeld, A B; Litovchenko, P G; Barabash, L I; Nemets, O F; Pavlenko, Yu N; Vasiliev, Yu O [Ukrainian Academy of Sciences, Kiev (Ukraine). Inst. for Nuclear Research

    1992-08-01

    A method has been developed to measure precisely the coordinates of charged particles incident between adjacent strips of a strip detector. The position sensitivity of an inter-strip gap has been studied by means of a pulsed laser beam and irradiation by [alpha]-particles of a [sup 226]Ra-source. The capacitive division of charge generated by the incident particle depends on the position of its track. Its coordinates were determined by two-dimensional amplitude analysis of the charges collected by neighbouring strips. This method of coordinate determination applied to studies of spatial and energy distributions of electromagnetic as well as charged particle beams (including radioactive ion beams) of low intensity could provide the highest level of the precision limited by the track dimensions of charged particles, i.e. percents of a micrometer. (orig.).

  7. Emotional Effects of Positive Forms of Communication

    OpenAIRE

    Светлана Валентиновна Ионова

    2015-01-01

    The article discusses the problem of emotional significance of a positive form of speech. Based on the methodology of emotions linguistics, linguoecology, communicative linguistics and the methods of description, comparison and discourse analysis, the author distinguishes some types of speech situations that demonstrate visible differences between positive expression of emotions and their content and the pragmatic effect. The difference between the notions of “positive communication” and “pos...

  8. Ontogenetic shifts of heart position in snakes.

    Science.gov (United States)

    Lillywhite, Harvey B; Lillywhite, Steven M

    2017-08-01

    Heart position relative to total body length (TL) varies among snakes, with anterior hearts in arboreal species and more centrally located hearts in aquatic or ground-dwelling species. Anterior hearts decrease the cardiac work associated with cranial blood flow and minimize drops in cranial pressure and flow during head-up climbing. Here, we investigate whether heart position shifts intraspecifically during ontogenetic increases in TL. Insular Florida cottonmouth snakes, Agkistrodon conanti, are entirely ground-dwelling and have a mean heart position that is 33.32% TL from the head. In contrast, arboreal rat snakes, Pantherophis obsoleta, of similar lengths have a mean heart position that is 17.35% TL from the head. In both species, relative heart position shifts craniad during ontogeny, with negative slopes = -.035 and -.021% TL/cm TL in Agkistrodon and Pantherophis, respectively. Using a large morphometric data set available for Agkistrodon (N = 192 individuals, 23-140 cm TL), we demonstrate there is an anterior ontogenetic shift of the heart position within the trunk (= 4.56% trunk length from base of head to cloacal vent), independent of head and tail allometry which are both negative. However, in longer snakes > 100 cm, the heart position reverses and shifts caudally in longer Agkistrodon but continues toward the head in longer individuals of Pantherophis. Examination of data sets for two independent lineages of fully marine snakes (Acrochordus granulatus and Hydrophis platurus), which do not naturally experience postural gravity stress, demonstrate both ontogenetic patterns for heart position that are seen in the terrestrial snakes. The anterior migration of the heart is greater in the terrestrial species, even if TL is standardized to that of the longer P. obsoleta, and compensates for about 5 mmHg gravitational pressure head if they are fully upright. © 2017 Wiley Periodicals, Inc.

  9. Influence of silver on the anodic corrosion and gas evolution of Pb-Sb-As-Se alloys as positive grids in lead acid batteries

    International Nuclear Information System (INIS)

    Tizpar, A.; Ghasemi, Z.

    2006-01-01

    The influence of silver addition in the range 0.01-0.09 wt.% on the anodic corrosion and gas evolution of Pb-Sb-As-Se alloy in 1.28 sp.gr. H 2 SO 4 solution at 25 deg. C was studied using linear sweep voltammetry, cyclic voltammetry, weight loss measurements and scanning electron microscopy. The results drawn from different techniques are comparable. The effect of different concentration of silver on the corrosion behavior of Pb-Sb-As-Se was investigated. The experimental results show that the silver added to Pb-Sb-As-Se alloy inhibits the growth of anodic corrosion layer. A decrease in the oxygen evolution overpotential and an increase in the hydrogen evolution overpotential with the addition of Ag were also observed during the experiments. Cyclic voltammetric measurements provided information on the effect of Ag on the oxidation of PbSO 4 to PbO 2

  10. Measurement of LHCD antenna position in Aditya tokamak

    International Nuclear Information System (INIS)

    Ambulkar, K K; Sharma, P K; Virani, C G; Parmar, P R; Thakur, A L; Kulkarni, S V

    2010-01-01

    To drive plasma current non-inductively in ADITYA tokamak, 120 kW pulsed Lower Hybrid Current Drive (LHCD) system at 3.7 GHz has been designed, fabricated and installed on ADITYA tokamak. In this system, the antenna consists of a grill structure, having two rows, each row comprising of four sub-waveguides. The coupling of LHCD power to the plasma strongly depends on the plasma density near the mouth of grill antenna. Thus the grill antenna has to be precisely positioned for efficient coupling. The movement of mechanical bellow, which contracts or expands up to 50mm, governs the movement of antenna. In order to monitor the position of the antenna precisely, the reference position of the antenna with respect to the machine/plasma position has to be accurately determined. Further a mechanical system or an electronic system to measure the relative movement of the antenna with respect to the reference position is also desired. Also due to poor accessibility inside the ADITYA machine, it is impossible to measure physically the reference position of the grill antenna with respect to machine wall, taken as reference position and hence an alternative method has to be adopted to establish these measurements reliably. In this paper we report the design and development of a mechanism, using which the antenna position measurements are made. It also describes a unique method employing which the measurements of the reference position of the antenna with respect to the inner edge of the tokamak wall is carried out, which otherwise was impossible due to poor accessibility and physical constraints. The position of the antenna is monitored using an electronic scale, which is developed and installed on the bellow. Once the reference position is derived, the linear potentiometer, attached to the bellow, measures the linear distance using position transmitter. The accuracy of measurement obtained in our setup is within +/- 0.5 % and the linearity, along with repeatability is excellent.

  11. The patient position for PNL: does it matter?

    Science.gov (United States)

    Cracco, Cecilia Maria; Scoffone, Cesare Marco; Poggio, Massimiliano; Scarpa, Roberto Mario

    2010-03-01

    Currently, PNL is the treatment of choice for large and/or otherwise complex urolithiasis. PNL was initially performed with the patient in a supine-oblique position, but later on the prone position became the conventional one for habit and handiness. The prone position provides a larger area for percutaneous renal access, a wider space for instrument manipulation, and a claimed lower risk of splanchnic injury. Nonetheless, it implies important anaesthesiological risks, including circulatory, haemodynamic, and ventilatory difficulties; need of several nurses to be present for intraoperative changes of the decubitus in case of simultaneous retrograde instrumentation of the ureter, implying evident risks related to pressure points; an increased radiological hazard to the urologist's hands; patient discomfort. To overcome these drawbacks, various safe and effective changes in patient positioning for PNL have been proposed over the years, including the reverse lithotomy position, the prone split-leg position, the lateral decubitus, the supine position, and the Galdakao-modified supine Valdivia (GMSV) position. Among these, the GMSV position is safe and effective, and seems profitable and ergonomic. It allows optimal cardiopulmonary control during general anaesthesia; an easy puncture of the kidney; a reduced risk of colonic injury; simultaneous antero-retrograde approach to the renal cavities (PNL and retrograde ureteroscopy = ECIRS, Endoscopic Combined IntraRenal Surgery), with no need of intraoperative repositioning of the anaesthetized patient, less need for nurses in the operating room, less occupational risk due to shifting of heavy loads, less risk of pressure injuries related to inaccurate repositioning, and reduced duration of the procedure; facilitated spontaneous evacuation of stone fragments; a comfortable sitting position and a restrained X-ray exposure of the hands for the urologist. But, first of all, GMSV position fully supports a new comprehensive

  12. Value co-creation in healthcare through positive deviance.

    Science.gov (United States)

    Zanetti, Cole Anthony; Taylor, Natalie

    2016-12-01

    To explore how converging fields of co-creation and positive deviance may increase value in healthcare. Informed by research in positive deviance, patient engagement, value co-creation, and quality improvement, we propose a positive deviance approach to co-creation of health. Co-creation has shown to improve health outcomes with regard to multiple health conditions. Positive deviance has also shown to improve outcomes in multiple healthcare and patient community environments. A positive deviance co-creation framework may aid in achieving improved outcomes for patients, care teams and their respective healthcare organizations. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Electrostatic beam-position monitor

    CERN Multimedia

    CERN PhotoLab

    1969-01-01

    Electrostatic beam-position monitor installed in its final location (bake-out cover removed). The ISR will contain about 110 of these monitors. Their accuracy is better than 1 mm, their band width about 1 MHz.

  14. Students’ strategies for position-taking in transnational education

    DEFF Research Database (Denmark)

    Li, Jin Hui

    2016-01-01

    as a field of struggle. The article discusses in depth how different student positions are led by the dispositions of having a certain nationality combined with international experiences/travel mobility. It will furthermore also discuss how the dispositions of national academic capital are related......The article illuminates the positions distributed and the strategies for position-taking which students pursue in order to transform or preserve their positions in a classroom with a transnational context where students have different national and international education experiences. Furthermore......, how their positions are related to their aspirations for the future will be elucidated. Based on interviews with Danish and Chinese students enrolled at a Sino-Danish university situated in Beijing, the article identifies four different navigation strategies for position-taking in such a classroom...

  15. Group identity and positive deviance in work groups.

    Science.gov (United States)

    Kim, Moon Joung; Choi, Jin Nam

    2017-12-05

    This study examines why and how identity cognitions, including group identification and individual differentiation, influence the positive deviance of employees. We identify the risk-taking intention of employees as a critical psychological mechanism to overcome stigma-induced identity threat of positive deviance. The analysis of data collected from 293 members comprising 66 work teams reveals that the relationship between individual differentiation and positive deviance is partially mediated by risk-taking intention. The indirect effect of group identification on positive deviance through risk-taking intention is also significant and positive in groups with low conformity pressure, whereas the same indirect effect is neutralized in groups with high conformity pressure. The current analysis offers new insights into the way the group context and the identity cognition of members explain the development of positive deviance and workplace creativity.

  16. The Promise of Positive Psychology

    Directory of Open Access Journals (Sweden)

    Mihaly Csikszentmihalyi

    2009-12-01

    Full Text Available Positive Psychology has demonstrated its usefulness in studying and contributing to individual well being. The next big challenge for this new field is to help improving the social and cultural conditions in which people live. Three specific goals are discussed: A more complete understanding of human nature; forging a more sustainable and more fair social contract; and a rediscovery of the joys of existence. If Positive Psychology will be able to support these goals, it will become an important contributor to the evolution of human consciousness and the evolution of culture.

  17. A large area position-sensitive ionization chamber for heavy-ion-induced reaction studies

    CERN Document Server

    Pant, L M; Dinesh, B V; Thomas, R G; Saxena, A; Sawant, Y S; Choudhury, R K

    2002-01-01

    A large area position-sensitive ionization chamber with a wide dynamic range has been developed to measure the mass, charge and energy of the heavy ions and the fission fragments produced in heavy-ion-induced reactions. The split anode geometry of the detector makes it suitable for both particle identification and energy measurements for heavy ions and fission fragments. The detector has been tested with alpha particles from sup 2 sup 4 sup 1 Am- sup 2 sup 3 sup 9 Pu source, fission fragments from sup 2 sup 5 sup 2 Cf and the heavy-ion beams from the 14UD Mumbai Pelletron accelerator facility. Using this detector, measurements on mass and total kinetic energy distributions in heavy-ion-induced fusion-fission reactions have been carried out for a wide range of excitation energies. Results on deep inelastic collisions and mass-energy correlations on different systems using this detector setup are discussed.

  18. Automatic approach to deriving fuzzy slope positions

    Science.gov (United States)

    Zhu, Liang-Jun; Zhu, A.-Xing; Qin, Cheng-Zhi; Liu, Jun-Zhi

    2018-03-01

    Fuzzy characterization of slope positions is important for geographic modeling. Most of the existing fuzzy classification-based methods for fuzzy characterization require extensive user intervention in data preparation and parameter setting, which is tedious and time-consuming. This paper presents an automatic approach to overcoming these limitations in the prototype-based inference method for deriving fuzzy membership value (or similarity) to slope positions. The key contribution is a procedure for finding the typical locations and setting the fuzzy inference parameters for each slope position type. Instead of being determined totally by users in the prototype-based inference method, in the proposed approach the typical locations and fuzzy inference parameters for each slope position type are automatically determined by a rule set based on prior domain knowledge and the frequency distributions of topographic attributes. Furthermore, the preparation of topographic attributes (e.g., slope gradient, curvature, and relative position index) is automated, so the proposed automatic approach has only one necessary input, i.e., the gridded digital elevation model of the study area. All compute-intensive algorithms in the proposed approach were speeded up by parallel computing. Two study cases were provided to demonstrate that this approach can properly, conveniently and quickly derive the fuzzy slope positions.

  19. Indoor positioning using differential Wi-Fi lateration

    Science.gov (United States)

    Retscher, Guenther; Tatschl, Thomas

    2017-12-01

    For Wi-Fi positioning usually location fingerprinting or (tri)lateration are employed whereby the received signal strengths (RSSs) of the surrounding Wi-Fi Access Points (APs) are scanned on the mobile devices and used to perform localization. Within the scope of this study, the position of a mobile user is determined on the basis of lateration. Two new differential approaches are developed and compared to two common models, i.e., the one-slope and multi-wall model, for the conversion of the measured RSS of the Wi-Fi signals into ranges. The two novel methods are termed DWi-Fi as they are derived either from the well-known DGPS or VLBI positioning principles. They make use of a network of reference stations deployed in the area of interest. From continuous RSS observations on these reference stations correction parameters are derived and applied by the user in real-time. This approach leads to a reduced influence of temporal and spatial variations and various propagation effects on the positioning result. In practical use cases conducted in a multi-storey office building with three different smartphones, it is proven that the two DWi-Fi approaches outperform the common models as static positioning yielded to position errors of about 5 m in average under good spatial conditions.

  20. Accurate radiotherapy positioning system investigation based on video

    International Nuclear Information System (INIS)

    Tao Shengxiang; Wu Yican

    2006-01-01

    This paper introduces the newest research production on patient positioning method in accurate radiotherapy brought by Accurate Radiotherapy Treating System (ARTS) research team of Institute of Plasma Physics of Chinese Academy of Sciences, such as the positioning system based on binocular vision, the position-measuring system based on contour matching and the breath gate controlling system for positioning. Their basic principle, the application occasion and the prospects are briefly depicted. (authors)

  1. Diagnosing Dementia—Positive Signs

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Diagnosing Dementia—Positive Signs Past Issues / Fall 2007 Table of ... easy, affordable blood test that could accurately diagnose Alzheimer's disease (AD)—even before symptoms began to show? Researchers ...

  2. Age-related positivity enhancement is not universal: older Chinese look away from positive stimuli.

    Science.gov (United States)

    Fung, Helene H; Lu, Alice Y; Goren, Deborah; Isaacowitz, Derek M; Wadlinger, Heather A; Wilson, Hugh R

    2008-06-01

    Socioemotional selectivity theory postulates that with age, people are motivated to derive emotional meaning from life, leading them to pay more attention to positive relative to negative/neutral stimuli. The authors argue that cultures that differ in what they consider to be emotionally meaningful may show this preference to different extents. Using eye-tracking techniques, the authors compared visual attention toward emotional (happy, fearful, sad, and angry) and neutral facial expressions among 46 younger and 57 older Hong Kong Chinese. In contrast to prior Western findings, older but not younger Chinese looked away from happy facial expressions, suggesting that they do not show attentional preferences toward positive stimuli.

  3. Positive School and Classroom Environment: Precursors of Successful Implementation of Positive Youth Development Programs

    Directory of Open Access Journals (Sweden)

    Rachel C. F. Sun

    2008-01-01

    Full Text Available This case study was based on a school where the Tier 1 Program of the Project P.A.T.H.S. was integrated into the formal curriculum. In this case study, an interview with the school principal, vice-principal, and social worker was conducted in order to understand their perceptions of administrative arrangements and issues in the school, implementation characteristics, program effectiveness, program success, and overall impression. Results showed that several positive school and classroom attributes were conducive to program success, including positive school culture and belief in students' potentials, an inviting school environment, an encouraging classroom environment, high involvement of school administrative personnel, and systematic program arrangement.

  4. Automatic positioning control device for automatic control rod exchanger

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To attain accurate positioning for a control rod exchanger. Constitution: The present position for an automatic control rod exchanger is detected by a synchro generator. An aimed stopping position for the exchanger, a stop instruction range depending on the distantial operation delay in the control system and the inertia-running distance of the mechanical system, and a coincidence confirmation range depending on the required positioning accuracy are previously set. If there is a difference between the present position and the aimed stopping position, the automatic exchanger is caused to run toward the aimed stopping position. A stop instruction is generated upon arrival at the position within said stop instruction range, and a coincidence confirmation signal is generated upon arrival at the position within the coincidence confirmation range. Since uncertain factors such as operation delay in the control system and the inertia-running distance of the mechanical system that influence the positioning accuracy are made definite by the method of actual measurement or the like and the stop instruction range and the coincidence confirmation range are set based on the measured data, the accuracy for the positioning can be improved. (Ikeda, J.)

  5. Leisure Activity Engagement and Positive Affect Partially Mediate the Relationship Between Positive Views on Aging and Physical Health.

    Science.gov (United States)

    Hicks, Stephanie A; Siedlecki, Karen L

    2017-03-01

    To examine leisure activity engagement and positive affect as potential mediators for the relationships between positive views on aging (PVA) and two health outcomes: subjective health and physical limitations. Data from 5,194 participants from the German Ageing Survey (aged 40-91 years) were used to examine relationships between PVA to subjective health (assessed by self-rated health and perceived health change from past) and physical limitations (assessed via self-reported limitations on 10 activities). Leisure activity engagement and positive affect were examined as potential mediators in latent variable path analyses. Age moderation among these relationships was also examined. Leisure activity engagement and positive affect separately and jointly served to partially mediate the relationships between PVA and the health outcomes. When entered as joint mediators, positive affect no longer significantly predicted physical limitations, indicating a shared variance with leisure activity engagement. Age moderated the relationship between PVA and physical limitations; the relationship was stronger among older adults than among middle-aged adults. Leisure activity engagement and positive affect were shown to help explain the relationship between PVA and health, but differently for different health constructs and also among middle-aged and older adults. Findings provide further insight into ways in which PVA influence health. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. A positive stigma for child labor ?

    OpenAIRE

    Patrinos, Harry Anthony; Shafiq, M. Najeeb

    2008-01-01

    The authors introduce a simple empirical model that assumes a positive stigma (or norm) toward child labor that is common in some developing countries. They illustrate the positive stigma model using data from Guatemala. Controlling for several child and household-level characteristics, the analysis uses two instruments for measuring stigma: a child's indigenous background and the househol...

  7. Experiences matter: Positive emotions facilitate intrinsic motivation

    OpenAIRE

    Løvoll, Helga Synnevåg; Røysamb, Espen; Vittersø, Joar

    2017-01-01

    This paper has two major aims. First, to investigate how positive emotions and intrinsic motivation affect each other over time. Second, to test the effect of positive emotions and intrinsic motivation on subsequent educational choices. Through two ordinary study semesters, 64 sport students in Norway reported on their intrinsic motivation for outdoor activities (twice) as well as positive emotions after two three-day outdoor events (four times). Next autumn, students study choice was collect...

  8. Experiences matter: Positive emotions facilitate intrinsic motivation

    OpenAIRE

    Løvoll, Helga Synnevåg; Røysamb, Espen; Vittersø, Joar

    2017-01-01

    https://doi.org/10.1080/23311908.2017.1340083 This paper has two major aims. First, to investigate how positive emotions and intrinsic motivation affect each other over time. Second, to test the effect of positive emotions and intrinsic motivation on subsequent educational choices. Through two ordinary study semesters, 64 sport students in Norway reported on their intrinsic motivation for outdoor activities (twice) as well as positive emotions after two three-day outdoor e...

  9. Fractional-Order Control of Pneumatic Position Servosystems

    OpenAIRE

    Junyi, Cao; Binggang, Cao

    2011-01-01

    A fractional-order control strategy for pneumatic position servosystem is presented in this paper. The idea of the fractional calculus application to control theory was introduced in many works, and its advantages were proved. However, the realization of fractional-order controllers for pneumatic position servosystems has not been investigated. Based on the relationship between the pressure in cylinder and the rate of mass flow into the cylinder, the dynamic model of pneumatic position servo ...

  10. Future directions for positive body image research

    OpenAIRE

    Halliwell, E.

    2015-01-01

    The emergence of positive body image research during the last 10 years represents an important shift in the body image literature. The existing evidence provides a strong empirical basis for the study of positive body image and research has begun to address issues of age, gender, ethnicity, culture, development, and intervention in relation to positive body image. This article briefly reviews the existing evidence before outlining directions for future research. Specifically, six areas for fu...

  11. Procalcitonin levels in patients with positive blood culture, positive body fluid culture, sepsis, and severe sepsis: a cross-sectional study.

    Science.gov (United States)

    Yu, Ying; Li, Xia-Xi; Jiang, Ling-Xiao; Du, Meng; Liu, Zhan-Guo; Cen, Zhong-Ran; Wang, Hua; Guo, Zhen-Hui; Chang, Ping

    2016-01-01

    Numerous investigations on procalcitonin (PCT) have been carried out, although few with large sample size. To deal with the complexity of sepsis, an understanding of PCT in heterogeneous clinical conditions is required. Hospitalized patients aged 10-79 years were included in this retrospective and cross-sectional study. PCT tests were assayed within 2 days of blood culture. A total of 2952 cases (from 2538 patients) were enrolled in this study, including 440 cases in the 'positive BC' group, 123 cases in the 'positive body fluid culture' group, and 2389 cases in the 'negative all culture' group. Median PCT values were 4.53 ng/ml, 2.95 ng/ml, and 0.49 ng/ml, respectively. Median PCT values in the gram-negative BC group and gram-positive BC group, respectively, were 6.99 ng/ml and 2.96 ng/ml. Median PCT values in the 'positive hydrothorax culture' group, 'positive ascites culture' group, 'positive bile culture' group, and 'positive cerebrospinal fluid culture' group, respectively, were 1.39 ng/ml, 8.32 ng/ml, 5.98 ng/ml, and 0.46 ng/ml. In all, 357 cases were classified into the 'sepsis' group, 150 of them were classified into the 'severe sepsis' group. Median PCT values were 5.63 ng/ml and 11.06 ng/ml, respectively. PCT could be used in clinical algorithms to diagnose positive infections and sepsis. Different PCT levels could be related to different kinds of microbemia, different infection sites, and differing severity of sepsis.

  12. The influence of body position on Bielschowsky's test

    Directory of Open Access Journals (Sweden)

    Carlos R. Souza-Dias

    2014-04-01

    Full Text Available Purpose: To investigate the veracity of Jampolsky's statement that Bielschowsky's head tilt test is inverted if performed with the patient in the upside-down position and to interpret its neuromuscular mechanism. Methods: We present a series of 10 patients selected from a referred sample who were diagnosed with superior oblique paresis. Hypertropia was measured in the primary position, with the head erect and tilted toward both shoulders with the patient in the erect, supine, and upside-down positions. The last position was achieved by hanging the patient upside-down. Results: As expected, our results showed the veracity of Jampolsky's statement. The forced head tilt difference was inverted or significantly decreased when the test was performed in the upside-down position. Moreover, in all patients, Bielschowsky's phenomenon was neutralized in the supine body position, in which hypertropia with the head erect tended to vanish. In 3 patients, it disappeared completely. Conclusions: This study showed that, in patients with superior oblique paresis, differences in the extent of hypertropia in Bielschowsky's test tended to vanish when the test was performed with the patient in the supine position and invert when it was performed with the patient in the upside-down position.

  13. Solitons in dusty plasmas with positive dust grains

    International Nuclear Information System (INIS)

    Baluku, T. K.; Hellberg, M. A.; Mace, R. L.

    2008-01-01

    Although ''typical'' micrometer-sized dust grains in a space or laboratory plasma are often negatively charged because of collisions with the mobile electrons, there are environments in which grains may take on a positive charge. We consider a dusty plasma composed of electrons, positive ions and positive dust grains, and use the fluid dynamic paradigm to identify existence domains in parameter space for both dust-acoustic (DA) and dust-modified ion-acoustic (DIA) solitons. Only positive potential DA solitons are found. This represents an expected antisymmetry with the case of negative dust, where previously only negative solitons were reported. However, whereas for negative dust DIA solitons of either sign of potential may exist, we find that for the case of positive dust, DIA solitons are restricted to positive potentials only. The results for both positive and negative dust are consistent with an hypothesis that, in the absence of flows, the sign(s) of the soliton potential coincide(s) with the sign(s) of the species whose inertia is included in the calculation; i.e., the cold, supersonic species present in the plasma

  14. Interoception and positive symptoms in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Martina Ardizzi

    2016-07-01

    Full Text Available The present study focuses on the multifaceted concept of self-disturbance in schizophrenia, adding knowledge about a not yet investigated aspect, which is the interoceptive accuracy. Starting from the assumption that interoceptive accuracy requires an intact sense of self, which otherwise was proved to be altered in schizophrenia, the aim of the present study was to explore interoceptive accuracy in a group of schizophrenia patients, compared to healthy controls. Furthermore, the possible association between interoceptive accuracy and patients’ positive and negative symptomatology was assessed. To pursue these goals, a group of 23 schizophrenia patients and a group of 23 healthy controls performed a heartbeat perception task. Patients’ symptomatology was assessed by means of the Positive and Negative Syndrome Scale (PANSS. Results demonstrated significantly lower interoceptive accuracy in schizophrenia patients compared to healthy controls. This difference was not accounted for participants’ age, BMI, anxiety levels and heart rate. Furthermore, patients’ illness severity, attention and pharmacological treatment did not influence their interoceptive accuracy levels. Interestingly, a strong positive relation between interoceptive accuracy and positive symptoms severity, especially Grandiosity, was found. The present results demonstrate for the first time that interoceptive accuracy is altered in schizophrenia. Furthermore, they prove a specific association between interoceptive accuracy and positive symptomatology, suggesting that the symptom Grandiosity might be protective against an altered basic sense of self in patients characterized by higher sensibility to their inner bodily sensations.

  15. The dilemmas of victim positioning

    Directory of Open Access Journals (Sweden)

    Dorte Marie Søndergaard

    2015-08-01

    Full Text Available This article centres on some of the dilemmas contained within victim positioning. Such dilemmas are often overlooked by the authorities involved with people subjected to relational aggression. 2 For example, when teachers rule out cases of bullying because the victim has 'participated in' or 'laughed at' some of the bullies' initiatives, or when a rape victim's status as a victim is questioned because, in the lead up to the assault, she was supposedly friendly to the rapist. In these cases, it could be useful to explore the reason for the bullying victim's apparent collusion or to better understand the premises for the rape victim's positioning options in relation to the perpetrator. In other words, it could be fruitful to explore the dynamics and dilemmas of the victim position. In this article, I aim to reflect on the motivational conditions of the victim phenomenon. These reflections are based on an analysis of qualitative data produced through interviews with school children as well as on relevant secondary literature.

  16. System and method for acquisition management of subject position information

    Science.gov (United States)

    Carrender, Curt

    2005-12-13

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  17. System and method for acquisition management of subject position information

    Energy Technology Data Exchange (ETDEWEB)

    Carrender, Curt [Morgan Hill, CA

    2007-01-23

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  18. Den positive psykologis metoder

    DEFF Research Database (Denmark)

    Bogen introducerer til de mange metoder, som anvendes i positiv psykologi. dette sker ud fra en reflekteret tilgang, der ligeledes rummer bidrag fra kritisk psykologi med det formål at nuancere den positive psykologis forståelser...

  19. Stress Management: Positive Thinking

    Science.gov (United States)

    Healthy Lifestyle Stress management Positive thinking helps with stress management and can even improve your health. Practice overcoming negative self-talk ... with optimism is a key part of effective stress management. And effective stress management is associated with ...

  20. Students’ strategies for position-taking in transnational education

    DEFF Research Database (Denmark)

    Li, Jin Hui

    2016-01-01

    The article illuminates the positions distributed and the strategies for position-taking which students pursue in order to transform or preserve their positions in a classroom with a transnational context where students have different national and international education experiences. Furthermore...

  1. Position sensitive detector used to detect beam profile

    International Nuclear Information System (INIS)

    Zhao Xiaoyan; Zhao Zhizheng; Zu Kailing; Zheng Jianhua; Wang Yifang

    2003-01-01

    In order to study the detecting system of the residual-gas beam profile, we introduce the principle and construction of the Position Sensitive Detector (PSD). The performance of PSD is tested. Position resolution, position linearity, detection efficiency and background are obtained

  2. Conflict, Memory, and Positioning

    DEFF Research Database (Denmark)

    Brescó, Ignacio

    2016-01-01

    The aim of this paper was to bring the dialogical and multivoiced dimension of conflict to the fore in the study of how people remember a particular event in the past. Drawing from different case studies, it contains analyses of how subjects identifying with different political actors in the Basque...... conflict adopted their respective positions, and interpretation of the conflict, and how, in light of same, they reconstruct the failed peace process that took place in 2006 between the terrorist group ETA (Euzkadi ta Azcatasuna, or Basque Country and Freedom in English) and the Spanish government. Results...... show that the positioning adopted by participants gives rise to a certain form of interpreting the conflict, which, in turn, affects how the peace process is remembered. This occurs within a particular argumentative context in which each version constitutes an implicit response to a competing...

  3. How positioning strategies affect co-branding outcomes

    OpenAIRE

    Wason, Hilary; Charlton, Nathalie

    2015-01-01

    Co-branding is a widely applied strategy, with research indicating differential benefits to the parent brands. Past studies suggest the source of these differences may be due to the partners’ relative market position, and characteristics such as brand familiarity, brand equity and proximity to the consumer have been explored. However, the role of brand positioning has received little attention in the context of co-branding. The current study attempts to address this gap, considering the posit...

  4. The positive emotions that facilitate the fulfillment of needs may not be positive emotions at all: the role of ambivalence.

    Science.gov (United States)

    Moss, Simon A; Wilson, Samuel G

    2015-01-01

    According to some scholars, if individuals experience over three times as many positive emotions as negative emotions, they are more likely to thrive. We contend, however, that perhaps positive and negative emotions that overlap in time are likely to enhance wellbeing. Specifically, if positive and negative emotions are experienced simultaneously rather than separately-called ambivalent emotions-the fundamental needs of individuals are fulfilled more frequently. Considerable evidence supports this perspective. First, many emotions that enhance wellbeing, although classified as positive, also coincide with negative feelings. Second, ambivalent emotions, rather than positive or negative emotions separately, facilitate creativity and resilience. Third, ambivalent emotions activate distinct cognitive systems that enable individuals to form attainable goals, refine their skills, and enhance their relationships. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Brightness enhancement of plasma ion source by utilizing anode spot for nano applications

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeong-Shin; Lee, Yuna; Chung, Kyoung-Jae; Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Yoon-Jae [Samsung Electronics Co. Ltd., Gyeonggi 445-701 (Korea, Republic of); Park, Man-Jin [Research Institute of Nano Manufacturing System, Seoul National University of Science and Technology, Seoul 139-743 (Korea, Republic of); Moon, Dae Won [Nanobio Fusion Research Center, Korea Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of)

    2012-02-15

    Anode spots are known as additional discharges on positively biased electrode immersed in plasmas. The anode spot plasma ion source (ASPIS) has been investigated as a high brightness ion source for nano applications such as focused ion beam (FIB) and nano medium energy ion scattering (nano-MEIS). The generation of anode spot is found to enhance brightness of ion beam since the anode spot increases plasma density near the extraction aperture. Brightness of the ASPIS has been estimated from measurement of emittance for total ion beam extracted through sub-mm aperture. The ASPIS is installed to the FIB system. Currents and diameters of the focused beams with/without anode spot are measured and compared. As the anode spot is turned on, the enhancement of beam current is observed at fixed diameter of the focused ion beam. Consequently, the brightness of the focused ion beam is enhanced as well. For argon ion beam, the maximum normalized brightness of 12 300 A/m{sup 2} SrV is acquired. The ASPIS is applied to nano-MEIS as well. The ASPIS is found to increase the beam current density and the power efficiency of the ion source for nano-MEIS. From the present study, it is shown that the ASPIS can enhance the performance of devices for nano applications.

  6. Improved spring model-based collaborative indoor visible light positioning

    Science.gov (United States)

    Luo, Zhijie; Zhang, WeiNan; Zhou, GuoFu

    2016-06-01

    Gaining accuracy with indoor positioning of individuals is important as many location-based services rely on the user's current position to provide them with useful services. Many researchers have studied indoor positioning techniques based on WiFi and Bluetooth. However, they have disadvantages such as low accuracy or high cost. In this paper, we propose an indoor positioning system in which visible light radiated from light-emitting diodes is used to locate the position of receivers. Compared with existing methods using light-emitting diode light, we present a high-precision and simple implementation collaborative indoor visible light positioning system based on an improved spring model. We first estimate coordinate position information using the visible light positioning system, and then use the spring model to correct positioning errors. The system can be employed easily because it does not require additional sensors and the occlusion problem of visible light would be alleviated. We also describe simulation experiments, which confirm the feasibility of our proposed method.

  7. Global positioning method based on polarized light compass system

    Science.gov (United States)

    Liu, Jun; Yang, Jiangtao; Wang, Yubo; Tang, Jun; Shen, Chong

    2018-05-01

    This paper presents a global positioning method based on a polarized light compass system. A main limitation of polarization positioning is the environment such as weak and locally destroyed polarization environments, and the solution to the positioning problem is given in this paper which is polarization image de-noising and segmentation. Therefore, the pulse coupled neural network is employed for enhancing positioning performance. The prominent advantages of the present positioning technique are as follows: (i) compared to the existing position method based on polarized light, better sun tracking accuracy can be achieved and (ii) the robustness and accuracy of positioning under weak and locally destroyed polarization environments, such as cloudy or building shielding, are improved significantly. Finally, some field experiments are given to demonstrate the effectiveness and applicability of the proposed global positioning technique. The experiments have shown that our proposed method outperforms the conventional polarization positioning method, the real time longitude and latitude with accuracy up to 0.0461° and 0.0911°, respectively.

  8. An Environmental Approach to Positive Emotion: Flowers

    Directory of Open Access Journals (Sweden)

    Jeannette Haviland-Jones

    2005-01-01

    Full Text Available For more than 5000 years, people have cultivated flowers although there is no known reward for this costly behavior. In three different studies we show that flowers are a powerful positive emotion “inducer”. In Study 1, flowers, upon presentation to women, always elicited the Duchenne or true smile. Women who received flowers reported more positive moods 3 days later. In Study 2, a flower given to men or women in an elevator elicited more positive social behavior than other stimuli. In Study 3, flowers presented to elderly participants (55+ age elicited positive mood reports and improved episodic memory. Flowers have immediate and long-term effects on emotional reactions, mood, social behaviors and even memory for both males and females. There is little existing theory in any discipline that explains these findings. We suggest that cultivated flowers are rewarding because they have evolved to rapidly induce positive emotion in humans, just as other plants have evolved to induce varying behavioral responses in a wide variety of species leading to the dispersal or propagation of the plants.

  9. Seroprevalence of Epstein-Barr virus among HIV positive patients moreover and its association with CD4 positive lymphocyte count.

    Directory of Open Access Journals (Sweden)

    Alireza Abdollahi

    2014-12-01

    Full Text Available Opportunistic infections are the leading cause of hospitalization and morbidity in human immunodeficiency virus (HIV positive patients and are the most common cause of death between them. We aimed to measure IgG antibody against EBV viral capsid antigen (EBV-VCA IgG to determine the seroprevalence of this infection in HIV-positive population. A case-control study between September 2011 and October 2012 was conducted in a teaching hospital enrolling 114 HIV-positive patients as case group and 114 healthy individuals as control with similar age and sex. Enzyme-linked immunosurbant assay (ELISA technique was used for determination of EBV-VAC IgG in obtained samples. Of 114 serum samples obtained from HIV-positive patients, 103 (90.4% samples were found positive for EBV-VCA IgG antibody. There was no significant difference in seroprevalence of EBV VCA IgG antibody between patients received antiretroviral therapy and naive patients (91.5% vs. 87.5%, P>0.05. There was no statistically significant difference in EBV-VCA IgG seroprevalence between three groups of CD4+ in HIV positive group. In conclusion current study showed that seroprevalence of EBV in HIV-positive patients is higher than HIV-negative healthy participants; however, administration of HAART and CD4+ lymphocyte count did not reveal a significant effect in seroprevalence of EBV. Due to the significance of this virus in mortality and morbidity and causing certain malignancies in patients with AIDS, these patients are strongly recommended to be tested for this virus.

  10. 75 FR 77783 - Designation of National Security Positions

    Science.gov (United States)

    2010-12-14

    ... requiring eligibility for access to Top Secret or ``Q'' classified information; (ii) Positions involving... at the Top Secret or ``Q'' level; (xix) Positions working with significant life-critical/mission... Sensitive information, requiring involvement in Top Secret Special Access Programs (SAP), or positions which...

  11. Menopausal women's positive experience of growing older

    DEFF Research Database (Denmark)

    Hvas, Lotte

    2006-01-01

    This paper aims to describe menopausal women's positive experience of growing older and becoming middle-aged.......This paper aims to describe menopausal women's positive experience of growing older and becoming middle-aged....

  12. Positive Education for Young Children: Effects of a Positive Psychology Intervention for Preschool Children on Subjective Well Being and Learning Behaviors

    Directory of Open Access Journals (Sweden)

    Anat Shoshani

    2017-10-01

    Full Text Available Despite the flourishing in recent years in applications of positive psychology in the field of education, there is a paucity of research investigating positive psychology interventions for preschool children. The present study examined the effects of a positive psychology-based intervention conducted in Israel on children’s subjective well-being, mental health and learning behaviors. Twelve preschool classrooms of 3–6.5 year-olds were randomly assigned to a positive psychology intervention condition or a wait-list control condition. In the intervention condition, during one school year, 160 children experienced eight modules of basic concepts in positive psychology that were adapted to the developmental characteristics of young children and were compared to 155 children in demographically similar control classrooms. Children were administered a pre-test and post-test of subjective well-being measures. In addition, children’s mental health and emotional well-being were measured by parental questionnaires. Preschool teachers completed questionnaires concerning children’s learning behaviors. The findings showed significant increases in subjective well-being and positive learning behaviors among the intervention participants, with no significant changes in the control group. The results highlight the potential of positive psychology interventions for increasing subjective well-being and a positive approach to learning at young ages.

  13. Positive tertiary appraisals and posttraumatic stress disorder in U.S. male veterans of the war in Vietnam: the roles of positive affirmation, positive reformulation, and defensive denial.

    Science.gov (United States)

    Dohrenwend, Bruce P; Neria, Yuval; Turner, J Blake; Turse, Nicholas; Marshall, Randall; Lewis-Fernandez, Roberto; Koenen, Karestan C

    2004-06-01

    A 70.9% majority of the U.S. male veterans in a nationwide sample appraised the impact of their service in Vietnam on their present lives as mainly positive. A substantial minority, 41.7%, judged the effects to be highly salient. With controls on level of exposure to war-zone stressors measured with data from military records, the valence and salience of these appraisals are investigated in relation to posttraumatic stress disorder (PTSD) and other indicators of wartime and postwar functioning. The results are consistent with the hypothesis that mainly positive tertiary appraisals are affirmations of successful wartime and postwar adaptation rather than defensive denials related to maladaptive outcomes. The possibility that mainly positive tertiary appraisals also contribute to successful postwar adaptation is discussed. (c) 2004 APA, all rights reserved

  14. 2D position sensitive microstrip sensors with charge division along the strip Studies on the position measurement error

    CERN Document Server

    Bassignana, D; Fernandez, M; Jaramillo, R; Lozano, M; Munoz, F.J; Pellegrini, G; Quirion, D; Vila, I; Vitorero, F

    2013-01-01

    Position sensitivity in semiconductor detectors of ionizing radiation is usually achieved by the segmentation of the sensing diode junction in many small sensing elements read out separately as in the case of conventional microstrips and pixel detectors. Alternatively, position sensitivity can be obtained by splitting the ionization signal collected by one single electrode amongst more than one readout channel with the ratio of the collected charges depending on the position where the signal was primary generated. Following this later approach, we implemented the charge division method in a conventional microstrip detector to obtain position sensitivity along the strip. We manufactured a proofof-concept demonstrator where the conventional aluminum electrodes were replaced by slightly resistive electrodes made of strongly doped poly-crystalline silicon and being readout at both strip ends. Here, we partially summarize the laser characterization of this first proof-of-concept demonstrator with special emphasis ...

  15. Assessing the efficiency position sensitive gaseous X-rays detectors

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Souza, Maria Ines Silvani; Lopes, Ricardo T.

    2009-01-01

    Full text: The efficiency of gaseous X-ray detectors can be evaluated from tabulated data, but this approach assumes that the whole detector volume is permeated by the electrostatic field produced by the anode-cathode. Indeed, the usual detectors are comprised by a cylindrical hull acting as cathode containing a wire at its axis as anode, a configuration which foods the space between them with the electrostatic field. Some specially designed detectors, however, as Position Sensitive Detectors, contain regions which are not submitted to the electrostatic field, and hence, their efficiency could not be assessed from the tabulated data. Direct measurements of this efficiency would require a mono-chromator or set of pure mono-energetic X-rays sources. As only very few of them are really mono-energetic, the detector response to a given energy would be spoiled by to the concomitant contribution of other energies. Yet, the information would not be completely lost, but only concealed due to the convolution carried out by the detector. Therefore, a proper unfolding would be capable to recover the information, yielding the individual detector efficiency for each of the contributing energies. The degraded information is retrieved in this work through a proper mathematical unfolding of the detector response, when exposed to Bremsstrahlung spectra from an X-ray tube submitted to different voltages. For this purpose, Lorentzian functions have been fitted to these spectra - obtained with a NaI(Tl) spectrometer - in order to characterize them with proper parameters. The mathematical convolution of these functions with a theoretical detector efficiency curve yields, after integration, values which, confronted with those experimentally measured, allow the determination of the parameters of the efficiency curve. As some parameters of this curve are well known, it is possible to represent it by proper functions. For argon-filled detectors, for instance, this efficiency has a

  16. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  17. Positive Education for Young Children: Effects of a Positive Psychology Intervention for Preschool Children on Subjective Well Being and Learning Behaviors

    OpenAIRE

    Anat Shoshani; Michelle Slone

    2017-01-01

    Despite the flourishing in recent years in applications of positive psychology in the field of education, there is a paucity of research investigating positive psychology interventions for preschool children. The present study examined the effects of a positive psychology-based intervention conducted in Israel on children’s subjective well-being, mental health and learning behaviors. Twelve preschool classrooms of 3–6.5 year-olds were randomly assigned to a positive psychology intervention co...

  18. 21-Gene Recurrence Score and Locoregional Recurrence in Node-Positive/ER-Positive Breast Cancer Treated With Chemo-Endocrine Therapy.

    Science.gov (United States)

    Mamounas, Eleftherios P; Liu, Qing; Paik, Soonmyung; Baehner, Frederick L; Tang, Gong; Jeong, Jong-Hyeon; Kim, S Rim; Butler, Steven M; Jamshidian, Farid; Cherbavaz, Diana B; Sing, Amy P; Shak, Steven; Julian, Thomas B; Lembersky, Barry C; Wickerham, D Lawrence; Costantino, Joseph P; Wolmark, Norman

    2017-01-01

    The 21-gene recurrence score (RS) predicts risk of locoregional recurrence (LRR) in node-negative, estrogen receptor (ER)-positive breast cancer. We evaluated the association between RS and LRR in node-positive, ER-positive patients treated with adjuvant chemotherapy plus tamoxifen in National Surgical Adjuvant Breast and Bowel Project B-28. B-28 compared doxorubicin/cyclophosphamide (AC X 4) with AC X 4 followed by paclitaxel X 4. Tamoxifen was given to patients age 50 years or older and those younger than age 50 years with ER-positive and/or progesterone receptor-positive tumors. Lumpectomy patients received breast radiotherapy. Mastectomy patients received no radiotherapy. The present study includes 1065 ER-positive, tamoxifen-treated patients with RS assessment. Cumulative incidence functions and subdistribution hazard regression models were used for LRR to account for competing risks including distant recurrence, second primary cancers, and death from other causes. Median follow-up was 11.2 years. All statistical tests were one-sided. There were 80 LRRs (7.5%) as first events (68% local/32% regional). RS was low: 36.2%; intermediate: 34.2%; and high: 29.6%. RS was a statistically significant predictor of LRR in univariate analyses (10-year cumulative incidence of LRR = 3.3%, 7.2%, and 12.2% for low, intermediate, and high RS, respectively, P < .001). In multivariable regression analysis, RS remained an independent predictor of LRR (hazard ratio [HR] = 2.59, 95% confidence interval [CI] = 1.28 to 5.26, for a 50-point difference, P = .008) along with pathologic nodal status (HR = 1.91, 95% CI = 1.20 to 3.03, for four or more vs one to three positive nodes, P = .006) and tumor size (HR = 1.28, 95% CI = 1.05 to 1.55, for a 1 cm difference, P = .02). RS statistically significantly predicts risk of LRR in node-positive, ER-positive breast cancer patients after adjuvant chemotherapy plus tamoxifen. These findings can help in the selection of

  19. Exploring positive hospital ward soundscape interventions.

    Science.gov (United States)

    Mackrill, J; Jennings, P; Cain, R

    2014-11-01

    Sound is often considered as a negative aspect of an environment that needs mitigating, particularly in hospitals. It is worthwhile however, to consider how subjective responses to hospital sounds can be made more positive. The authors identified natural sound, steady state sound and written sound source information as having the potential to do this. Listening evaluations were conducted with 24 participants who rated their emotional (Relaxation) and cognitive (Interest and Understanding) response to a variety of hospital ward soundscape clips across these three interventions. A repeated measures ANOVA revealed that the 'Relaxation' response was significantly affected (n(2) = 0.05, p = 0.001) by the interventions with natural sound producing a 10.1% more positive response. Most interestingly, written sound source information produced a 4.7% positive change in response. The authors conclude that exploring different ways to improve the sounds of a hospital offers subjective benefits that move beyond sound level reduction. This is an area for future work to focus upon in an effort to achieve more positively experienced hospital soundscapes and environments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Radon-Nikodym type theorem for α-completely positive maps

    International Nuclear Information System (INIS)

    Heo, Jaeseong; Ji, Un Cig

    2010-01-01

    We introduce a new notion of α-completely positive map on a C*-algebra as a generalization of the notion of completely positive map. Then we study a theorem of the Radon-Nikodym type that there is a one-to-one correspondence between α-completely positive maps and positive operators and, as an application of the Radon-Nikodym type theorem, we give a characterization of pure α-completely positive maps. Finally, we study a covariant version of the Stinespring's theorem for a covariant α-completely positive map (see Theorem 4.3).