WorldWideScience

Sample records for portion size measurement

  1. Portion size

    Science.gov (United States)

    ... of cards One 3-ounce (84 grams) serving of fish is a checkbook One-half cup (40 grams) ... for the smallest size. By eating a small hamburger instead of a large, you will save about 150 calories. ...

  2. The international food unit: a new measurement aid that can improve portion size estimation.

    Science.gov (United States)

    Bucher, T; Weltert, M; Rollo, M E; Smith, S P; Jia, W; Collins, C E; Sun, M

    2017-09-12

    Portion size education tools, aids and interventions can be effective in helping prevent weight gain. However consumers have difficulties in estimating food portion sizes and are confused by inconsistencies in measurement units and terminologies currently used. Visual cues are an important mediator of portion size estimation, but standardized measurement units are required. In the current study, we present a new food volume estimation tool and test the ability of young adults to accurately quantify food volumes. The International Food Unit™ (IFU™) is a 4x4x4 cm cube (64cm 3 ), subdivided into eight 2 cm sub-cubes for estimating smaller food volumes. Compared with currently used measures such as cups and spoons, the IFU™ standardizes estimation of food volumes with metric measures. The IFU™ design is based on binary dimensional increments and the cubic shape facilitates portion size education and training, memory and recall, and computer processing which is binary in nature. The performance of the IFU™ was tested in a randomized between-subject experiment (n = 128 adults, 66 men) that estimated volumes of 17 foods using four methods; the IFU™ cube, a deformable modelling clay cube, a household measuring cup or no aid (weight estimation). Estimation errors were compared between groups using Kruskall-Wallis tests and post-hoc comparisons. Estimation errors differed significantly between groups (H(3) = 28.48, p studies should investigate whether the IFU™ can facilitate portion size training and whether portion size education using the IFU™ is effective and sustainable without the aid. A 3-dimensional IFU™ could serve as a reference object for estimating food volume.

  3. Missing portion sizes in FFQ

    DEFF Research Database (Denmark)

    Køster-Rasmussen, Rasmus; Siersma, Volkert Dirk; Halldorson, Thorhallur I.

    2015-01-01

    -nearest neighbours (KNN) were compared with a reference based on self-reported portion sizes (quantified by a photographic food atlas embedded in the FFQ). Setting: The Danish Health Examination Survey 2007–2008. Subjects: The study included 3728 adults with complete portion size data. Results: Compared...

  4. Portion distortion: typical portion sizes selected by young adults.

    Science.gov (United States)

    Schwartz, Jaime; Byrd-Bredbenner, Carol

    2006-09-01

    The incidence of obesity has increased in parallel with increasing portion sizes of individually packaged and ready-to-eat prepared foods as well as foods served at restaurants. Portion distortion (perceiving large portion sizes as appropriate amounts to eat at a single eating occasion) may contribute to increasing energy intakes and expanding waistlines. The purpose of this study was to determine typical portion sizes that young adults select, how typical portion sizes compare with reference portion sizes (based in this study on the Nutrition Labeling and Education Act's quantities of food customarily eaten per eating occasion), and whether the size of typical portions has changed over time. Young adults (n=177, 75% female, age range 16 to 26 years) at a major northeastern university. Participants served themselves typical portion sizes of eight foods at breakfast (n=63) or six foods at lunch or dinner (n=62, n=52, respectively). Typical portion-size selections were unobtrusively weighed. A unit score was calculated by awarding 1 point for each food with a typical portion size that was within 25% larger or smaller than the reference portion; larger or smaller portions were given 0 points. Thus, each participant's unit score could range from 0 to 8 at breakfast or 0 to 6 at lunch and dinner. Analysis of variance or t tests were used to determine whether typical and reference portion sizes differed, and whether typical portion sizes changed over time. Mean unit scores (+/-standard deviation) were 3.63+/-1.27 and 1.89+/-1.14, for breakfast and lunch/dinner, respectively, indicating little agreement between typical and reference portion sizes. Typical portions sizes in this study tended to be significantly different from those selected by young adults in a similar study conducted 2 decades ago. Portion distortion seems to affect the portion sizes selected by young adults for some foods. This phenomenon has the potential to hinder weight loss, weight maintenance, and

  5. Visual exposure to large and small portion sizes and perceptions of portion size normality: Three experimental studies

    OpenAIRE

    Robinson, Eric; Oldham, Melissa; Cuckson, Imogen; Brunstrom, Jeffrey M.; Rogers, Peter J.; Hardman, Charlotte A.

    2016-01-01

    Portion sizes of many foods have increased in recent times. In three studies we examined the effect that repeated visual exposure to larger versus smaller food portion sizes has on perceptions of what constitutes a normal-sized food portion and measures of portion size selection. In studies 1 and 2 participants were visually exposed to images of large or small portions of spaghetti bolognese, before making evaluations about an image of an intermediate sized portion of the same food. In study ...

  6. Portion size and intended consumption. Evidence for a pre-consumption portion size effect in males?

    Science.gov (United States)

    Robinson, Eric; te Raa, Wesselien; Hardman, Charlotte A

    2015-08-01

    Larger portions increase energy intake (the 'portion size effect'); however, the mechanisms behind this effect are unclear. Although pre-meal intentions are thought to be an important determinant of energy intake, little research has examined how much of a meal individuals intend to eat when served standard versus larger portion sizes. Three studies examined the effect of manipulating portion size on intended food consumption. In Studies 1 (spaghetti bolognese) and 2 (curry and rice) male participants were shown an image of either a standard or a larger meal and indicated how much of the meal they intended to consume. In Study 3 male and female participants were served either a standard or a larger portion of ice cream for dessert, they indicated how much they intended to consume and then ate as much of the ice cream as they desired. Regardless of being shown standard or large portion sizes, in Studies 1 and 2 participants reported that they intended to eat the majority of the meal, equating to a large difference in intended energy consumption between portion size conditions (a 'pre-consumption portion size effect'). This finding was replicated in male participants in Study 3, although females intended to eat a smaller proportion of the larger portion of ice cream, compared to the standard portion. Both male and female participants tended to eat in accordance with their pre-meal intentions and a portion size effect on actual consumption was subsequently observed in males, but not in females. The portion size effect may be observed when measuring pre-meal intended consumption in males. Copyright © 2015. Published by Elsevier Ltd.

  7. Chefs' opinions of restaurant portion sizes.

    Science.gov (United States)

    Condrasky, Marge; Ledikwe, Jenny H; Flood, Julie E; Rolls, Barbara J

    2007-08-01

    The objectives were to determine who establishes restaurant portion sizes and factors that influence these decisions, and to examine chefs' opinions regarding portion size, nutrition information, and weight management. A survey was distributed to chefs to obtain information about who is responsible for determining restaurant portion sizes, factors influencing restaurant portion sizes, what food portion sizes are being served in restaurants, and chefs' opinions regarding nutrition information, health, and body weight. The final sample consisted of 300 chefs attending various culinary meetings. Executive chefs were identified as being primarily responsible for establishing portion sizes served in restaurants. Factors reported to have a strong influence on restaurant portion sizes included presentation of foods, food cost, and customer expectations. While 76% of chefs thought that they served "regular" portions, the actual portions of steak and pasta they reported serving were 2 to 4 times larger than serving sizes recommended by the U.S government. Chefs indicated that they believe that the amount of food served influences how much patrons consume and that large portions are a problem for weight control, but their opinions were mixed regarding whether it is the customer's responsibility to eat an appropriate amount when served a large portion of food. Portion size is a key determinant of energy intake, and the results from this study suggest that cultural norms and economic value strongly influence the determination of restaurant portion sizes. Strategies are needed to encourage chefs to provide and promote portions that are appropriate for customers' energy requirements.

  8. Prevention of the Portion Size Effect

    NARCIS (Netherlands)

    I. Versluis (Iris)

    2016-01-01

    markdownabstractAn increase in the portion size leads to an increase in energy intake, a phenomenon which is also referred to as the portion size effect. The increase in portion sizes in recent years is regarded as an important contributor to the increase in the prevalence of obesity. Hence, the aim

  9. Visual exposure to large and small portion sizes and perceptions of portion size normality: Three experimental studies.

    Science.gov (United States)

    Robinson, Eric; Oldham, Melissa; Cuckson, Imogen; Brunstrom, Jeffrey M; Rogers, Peter J; Hardman, Charlotte A

    2016-03-01

    Portion sizes of many foods have increased in recent times. In three studies we examined the effect that repeated visual exposure to larger versus smaller food portion sizes has on perceptions of what constitutes a normal-sized food portion and measures of portion size selection. In studies 1 and 2 participants were visually exposed to images of large or small portions of spaghetti bolognese, before making evaluations about an image of an intermediate sized portion of the same food. In study 3 participants were exposed to images of large or small portions of a snack food before selecting a portion size of snack food to consume. Across the three studies, visual exposure to larger as opposed to smaller portion sizes resulted in participants considering a normal portion of food to be larger than a reference intermediate sized portion. In studies 1 and 2 visual exposure to larger portion sizes also increased the size of self-reported ideal meal size. In study 3 visual exposure to larger portion sizes of a snack food did not affect how much of that food participants subsequently served themselves and ate. Visual exposure to larger portion sizes may adjust visual perceptions of what constitutes a 'normal' sized portion. However, we did not find evidence that visual exposure to larger portions altered snack food intake. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. 6 Tips for Managing Portion Size

    Science.gov (United States)

    Eating healthy is about enjoying your food while also managing portion size. Most people eat and drink more than their bodies need especially when they are served larger portions. So, choosing smaller portions to begin with is important for maintaining your overall health and well-being.

  11. Model-based measurement of food portion size for image-based dietary assessment using 3D/2D registration

    International Nuclear Information System (INIS)

    Chen, Hsin-Chen; Yue, Yaofeng; Sun, Mingui; Jia, Wenyan; Li, Zhaoxin; Sun, Yung-Nien; Fernstrom, John D

    2013-01-01

    Dietary assessment is important in health maintenance and intervention in many chronic conditions, such as obesity, diabetes and cardiovascular disease. However, there is currently a lack of convenient methods for measuring the volume of food (portion size) in real-life settings. We present a computational method to estimate food volume from a single photographic image of food contained on a typical dining plate. First, we calculate the food location with respect to a 3D camera coordinate system using the plate as a scale reference. Then, the food is segmented automatically from the background in the image. Adaptive thresholding and snake modeling are implemented based on several image features, such as color contrast, regional color homogeneity and curve bending degree. Next, a 3D model representing the general shape of the food (e.g., a cylinder, a sphere, etc) is selected from a pre-constructed shape model library. The position, orientation and scale of the selected shape model are determined by registering the projected 3D model and the food contour in the image, where the properties of the reference are used as constraints. Experimental results using various realistically shaped foods with known volumes demonstrated satisfactory performance of our image-based food volume measurement method even if the 3D geometric surface of the food is not completely represented in the input image. (paper)

  12. Portion and Serving Sizes of Commonly Consumed Foods, in ...

    African Journals Online (AJOL)

    Portion sizes were determined from weight equivalents of each food type consumed, average portion sizes for each food type were determined using the statistical ... Serving sizes determined: a serving of the various foods as expressed in household measures include; 1.3 slices of bread, 13.5 tablespoons of Ewedu soup, ...

  13. Container size influences snack food intake independently of portion size.

    Science.gov (United States)

    Marchiori, David; Corneille, Olivier; Klein, Olivier

    2012-06-01

    While larger containers have been found to increase food intake, it is unclear whether this effect is driven by container size, portion size, or their combination, as these variables are usually confounded. The study was advertised as examining the effects of snack food consumption on information processing and participants were served M&M's for free consumption in individual cubicles while watching a TV show. Participants were served (1) a medium portion of M&M's in a small (n=30) or (2) in a large container (n=29), or (3) a large portion in a large container (n=29). The larger container increased intake by 129% (199 kcal) despite holding portion size constant, while controlling for different confounding variables. This research suggests that larger containers stimulate food intake over and above their impact on portion size. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Evaluation of a digital food photography atlas used as portion size measurement aid in dietary surveys in Greece.

    Science.gov (United States)

    Naska, Androniki; Valanou, Elisavet; Peppa, Eleni; Katsoulis, Michail; Barbouni, Anastasia; Trichopoulou, Antonia

    2016-09-01

    To evaluate how well respondents perceive digital images of food portions commonly consumed in Greece. The picture series was defined on the basis of usual dietary intakes assessed in earlier large-scale studies in Greece. The evaluation included 2218 pre-weighed actual portions shown to participants, who were subsequently asked to link each portion to a food picture. Mean differences between picture numbers selected and portions actually shown were compared using the Wilcoxon paired signed-rank test. The effect of personal characteristics on participants' selections was evaluated through unpaired t tests (sex and school years) or through Tukey-Kramer pairwise comparisons (age and food groups). Testing of participants' perception of digital food images used in the Greek national nutrition survey. Individuals (n 103, 61 % females) aged 12 years and over, selected on the basis of the target population of the Greek nutrition survey using convenience sampling. Individuals selected the correct or adjacent image in about 90 % of the assessments and tended to overestimate small and underestimate large quantities. Photographs of Greek traditional pies and meat-based pastry dishes led participants to perceive the amounts in the photos larger than they actually were. Adolescents were more prone to underestimating food quantities through the pictures. The digital food atlas appears generally suitable to be used for the estimation of average food intakes in large-scale dietary surveys in Greece. However, individuals who consistently consume only small or only large food portions may have biased perceptions in relation to others.

  15. Portion size: a qualitative study of consumers' attitudes toward point-of-purchase interventions aimed at portion size.

    Science.gov (United States)

    Vermeer, Willemijn M; Steenhuis, Ingrid H M; Seidell, Jacob C

    2010-02-01

    This qualitative study assessed consumers' opinions of food portion sizes and their attitudes toward portion-size interventions located in various point-of-purchase settings targeting overweight and obese people. Eight semi-structured focus group discussions were conducted with 49 participants. Constructs from the diffusion of innovations theory were included in the interview guide. Each focus group was recorded and transcribed verbatim. Data were coded and analyzed with Atlas.ti 5.2 using the framework approach. Results showed that many participants thought that portion sizes of various products have increased during the past decades and are larger than acceptable. The majority also indicated that value for money is important when purchasing and that large portion sizes offer more value for money than small portion sizes. Furthermore, many experienced difficulties with self-regulating the consumption of large portion sizes. Among the portion-size interventions that were discussed, participants had most positive attitudes toward a larger availability of portion sizes and pricing strategies, followed by serving-size labeling. In general, reducing package serving sizes as an intervention strategy to control food intake met resistance. The study concludes that consumers consider interventions consisting of a larger variety of available portion sizes, pricing strategies and serving-size labeling as most acceptable to implement.

  16. Food photographs in portion size estimation among adolescent Mozambican girls.

    Science.gov (United States)

    Korkalo, Liisa; Erkkola, Maijaliisa; Fidalgo, Lourdes; Nevalainen, Jaakko; Mutanen, Marja

    2013-09-01

    To assess the validity of food photographs in portion size estimation among adolescent girls in Mozambique. The study was carried out in preparation for the larger ZANE study, which used the 24 h dietary recall method. Life-sized photographs of three portion sizes of two staple foods and three sauces were produced. Participants ate weighed portions of one staple food and one sauce. After the meal, they were asked to estimate the amount of food with the aid of the food photographs. Zambezia Province, Mozambique. Ninety-nine girls aged 13–18 years. The mean differences between estimated and actual portion sizes relative to the actual portion size ranged from 219% to 8% for different foods. The respective mean difference for all foods combined was 25% (95% CI 212, 2 %). Especially larger portions of the staple foods were often underestimated. For the staple foods, between 62% and 64% of the participants were classified into the same thirds of the distribution of estimated and actual food consumption and for sauces, the percentages ranged from 38% to 63%. Bland–Altman plots showed wide limits of agreement. Using life-sized food photographs among adolescent Mozambican girls resulted in a rather large variation in the accuracy of individuals’ estimates. The ability to rank individuals according to their consumption was, however, satisfactory for most foods. There seems to be a need to further develop and test food photographs used in different populations in Sub-Saharan Africa to improve the accuracy of portion size estimates.

  17. Portion sizes and obesity: responses of fast-food companies.

    Science.gov (United States)

    Young, Lisa R; Nestle, Marion

    2007-07-01

    Because the sizes of food portions, especially of fast food, have increased in parallel with rising rates of overweight, health authorities have called on fast-food chains to decrease the sizes of menu items. From 2002 to 2006, we examined responses of fast-food chains to such calls by determining the current sizes of sodas, French fries, and hamburgers at three leading chains and comparing them to sizes observed in 1998 and 2002. Although McDonald's recently phased out its largest offerings, current items are similar to 1998 sizes and greatly exceed those offered when the company opened in 1955. Burger King and Wendy's have increased portion sizes, even while health authorities are calling for portion size reductions. Fast-food portions in the United States are larger than in Europe. These observations suggest that voluntary efforts by fast-food companies to reduce portion sizes are unlikely to be effective, and that policy approaches are needed to reduce energy intake from fast food.

  18. Patterns and trends in food portion sizes, 1977-1998.

    Science.gov (United States)

    Nielsen, Samara Joy; Popkin, Barry M

    While general consensus holds that food portion sizes are increasing, no empirical data have documented actual increases. To determine trends in food portion sizes consumed in the United States, by eating location and food source. Nationally representative data from the Nationwide Food Consumption Survey (1977-1978) and the Continuing Survey of Food Intake by Individuals (1989-1991, 1994-1996, and 1998). The sample consists of 63 380 individuals aged 2 years and older. For each survey year, average portion size consumed from specific food items (salty snacks, desserts, soft drinks, fruit drinks, french fries, hamburgers, cheeseburgers, pizza, and Mexican food) by eating location (home, restaurant, or fast food). Portion sizes vary by food source, with the largest portions consumed at fast food establishments and the smallest at other restaurants. Between 1977 and 1996, food portion sizes increased both inside and outside the home for all categories except pizza. The energy intake and portion size of salty snacks increased by 93 kcal (from 1.0 to 1.6 oz [28.4 to 45.4 g]), soft drinks by 49 kcal (13.1 to 19.9 fl oz [387.4 to 588.4 mL]), hamburgers by 97 kcal (5.7 to 7.0 oz [161.6 to 198.4 g]), french fries by 68 kcal (3.1 to 3.6 oz [87.9 to 102.1 g]), and Mexican food by 133 kcal (6.3 to 8.0 oz [178.6 to 226.8 g]). Portion sizes and energy intake for specific food types have increased markedly with greatest increases for food consumed at fast food establishments and in the home.

  19. Estimation of portion size in children's dietary assessment: lessons learnt.

    Science.gov (United States)

    Foster, E; Adamson, A J; Anderson, A S; Barton, K L; Wrieden, W L

    2009-02-01

    Assessing the dietary intake of young children is challenging. In any 1 day, children may have several carers responsible for providing them with their dietary requirements, and once children reach school age, traditional methods such as weighing all items consumed become impractical. As an alternative to weighed records, food portion size assessment tools are available to assist subjects in estimating the amounts of foods consumed. Existing food photographs designed for use with adults and based on adult portion sizes have been found to be inappropriate for use with children. This article presents a review and summary of a body of work carried out to improve the estimation of portion sizes consumed by children. Feasibility work was undertaken to determine the accuracy and precision of three portion size assessment tools; food photographs, food models and a computer-based Interactive Portion Size Assessment System (IPSAS). These tools were based on portion sizes served to children during the National Diet and Nutrition Survey. As children often do not consume all of the food served to them, smaller portions were included in each tool for estimation of leftovers. The tools covered 22 foods, which children commonly consume. Children were served known amounts of each food and leftovers were recorded. They were then asked to estimate both the amount of food that they were served and the amount of any food leftover. Children were found to estimate food portion size with an accuracy approaching that of adults using both the food photographs and IPSAS. Further development is underway to increase the number of food photographs and to develop IPSAS to cover a much wider range of foods and to validate the use of these tools in a 'real life' setting.

  20. Energy intake and obesity: ingestive frequency outweighs portion size.

    Science.gov (United States)

    Mattes, Richard

    2014-07-01

    Energy intake is a function of the quantity of energy consumed per ingestive event and the number of these events. The marked increase of energy intake and body weight over the past 35 years indicates that there has been poor precision in the reciprocity of these two facets of intake. With recent study of the associations between gut "satiation" peptides and energy intake, there has been an emphasis on the contribution of portion size to positive energy balance. However, this orientation may not appropriately weight the contribution of ingestive frequency. Gut peptides are not purely satiation factors and metabolic and environmental cues may more strongly guide the onset and number of ingestive events. Evidence is presented that while both portion size and ingestive frequency have increased in the population, the latter may be more problematic for weight gain. The magnitude and time course of increments in ingestive frequency map better onto energy intake and BMI trends than changes of portion size. This may occur, in part, because dietary compensation and thermogenic effects are weaker for increases in ingestive frequency than portion size. Though not to the exclusion of consideration of portion size effects, improved weight management may be achieved with greater attention to the drivers of eating and drinking frequency. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Children's estimates of food portion size: the development and evaluation of three portion size assessment tools for use with children.

    Science.gov (United States)

    Foster, E; Matthews, J N S; Lloyd, J; Marshall, L; Mathers, J C; Nelson, M; Barton, K L; Wrieden, W L; Cornelissen, P; Harris, J; Adamson, A J

    2008-01-01

    A number of methods have been developed to assist subjects in providing an estimate of portion size but their application in improving portion size estimation by children has not been investigated systematically. The aim was to develop portion size assessment tools for use with children and to assess the accuracy of children's estimates of portion size using the tools. The tools were food photographs, food models and an interactive portion size assessment system (IPSAS). Children (n 201), aged 4-16 years, were supplied with known quantities of food to eat, in school. Food leftovers were weighed. Children estimated the amount of each food using each tool, 24 h after consuming the food. The age-specific portion sizes represented were based on portion sizes consumed by children in a national survey. Significant differences were found between the accuracy of estimates using the three tools. Children of all ages performed well using the IPSAS and food photographs. The accuracy and precision of estimates made using the food models were poor. For all tools, estimates of the amount of food served were more accurate than estimates of the amount consumed. Issues relating to reporting of foods left over which impact on estimates of the amounts of foods actually consumed require further study. The IPSAS has shown potential for assessment of dietary intake with children. Before practical application in assessment of dietary intake of children the tool would need to be expanded to cover a wider range of foods and to be validated in a 'real-life' situation.

  2. The pack size effect: Influence on consumer perceptions of portion sizes

    NARCIS (Netherlands)

    Hieke, Sophie; Palascha, Aikaterini; Jola, Corinne; Wills, Josephine; Raats, Monique M.

    2016-01-01

    Larger portions as well as larger packs can lead to larger prospective consumption estimates, larger servings and increased consumption, described as 'portion-size effects' and 'pack size effects'. Although related, the effects of pack sizes on portion estimates have received less attention. While

  3. Effects of portion size on chronic energy intake

    Directory of Open Access Journals (Sweden)

    Pentel Paul R

    2007-06-01

    Full Text Available Abstract Background This study experimentally examined the effects of repeated exposure to different meal portion sizes on energy intake. Methods Nineteen employees of a county medical center were given free box lunches for two months, one month each of 1528 and 767 average kcal. Foods were identical in the two conditions, but differed in portion size. Meals averaged 44% calories from fat. Participants self-reported how much of each lunch was eaten. Unannounced 24-hour dietary recalls were also conducted by phone twice per week during each exposure period. Results Mean energy intake at the lunch meal was 332 kcal/day higher in large lunch than in small lunch periods (p Conclusion This study suggests that chronic exposure to large portion size meals can result in sustained increases in energy intake and may contribute to body weight increases over time.

  4. Portion Sizes from 24-Hour Dietary Recalls Differed by Sex among Those Who Selected the Same Portion Size Category on a Food Frequency Questionnaire.

    Science.gov (United States)

    Kang, Minji; Park, Song-Yi; Boushey, Carol J; Wilkens, Lynne R; Monroe, Kristine R; Le Marchand, Loïc; Kolonel, Laurence N; Murphy, Suzanne P; Paik, Hee-Young

    2018-05-08

    Accounting for sex differences in food portions may improve dietary measurement; however, this factor has not been well examined. The aim of this study was to examine sex differences in reported food portions from 24-hour dietary recalls (24HDRs) among those who selected the same portion size category on a quantitative food frequency questionnaire (QFFQ). This study was conducted with a cross-sectional design. Participants (n=319) were members of the Hawaii-Los Angeles Multiethnic Cohort who completed three 24HDRs and a QFFQ in a calibration study conducted in 2010 and 2011. Portions of individual foods reported from 24HDRs served as the outcome measures. Mean food portions from 24HDRs were compared between men and women who reported the same portion size on the QFFQ, after adjustment for race/ethnicity using a linear regression model. Actual amount and the assigned amount of the selected portion size in the QFFQ were compared using one-sample t test for men and women separately. Of 163 food items with portion size options listed in the QFFQ, 32 were reported in 24HDRs by ≥20 men and ≥20 women who selected the same portion size in the QFFQ. Although they chose the same portion size on the QFFQ, mean intake amounts from 24HDRs were significantly higher for men than for women for "beef/lamb/veal," "white rice," "brown/wild rice," "lettuce/tossed salad," "eggs cooked/raw," "whole wheat/rye bread," "buns/rolls," and "mayonnaise in sandwiches." For men, mean portions of 14 items from the 24HDRs were significantly different from the assigned amounts for QFFQ items (seven higher and seven lower), whereas for women, mean portions of 14 items were significantly lower from the assigned amounts (with five significantly higher). These sex differences in reported 24HDR food portions-even among participants who selected the same portion size on the QFFQ-suggest that the use of methods that account for differences in the portions consumed by men and women when QFFQs are

  5. Portion Size Labeling and Intended Soft Drink Consumption: The Impact of Labeling Format and Size Portfolio

    Science.gov (United States)

    Vermeer, Willemijn M.; Steenhuis, Ingrid H. M.; Leeuwis, Franca H.; Bos, Arjan E. R.; de Boer, Michiel; Seidell, Jacob C.

    2010-01-01

    Objective: To assess what portion size labeling "format" is most promising in helping consumers selecting appropriate soft drink sizes, and whether labeling impact depends on the size portfolio. Methods: An experimental study was conducted in fast-food restaurants in which 2 labeling formats (ie, reference portion size and small/medium/large…

  6. A qualitative study of parents' perceptions and use of portion size strategies for preschool children's snacks.

    Science.gov (United States)

    Blake, Christine E; Fisher, Jennifer Orlet; Ganter, Claudia; Younginer, Nicholas; Orloski, Alexandria; Blaine, Rachel E; Bruton, Yasmeen; Davison, Kirsten K

    2015-05-01

    Increases in childhood obesity correspond with shifts in children's snacking behaviors and food portion sizes. This study examined parents' conceptualizations of portion size and the strategies they use to portion snacks in the context of preschool-aged children's snacking. Semi-structured qualitative interviews were conducted with non-Hispanic white (W), African American (AA), and Hispanic (H) low-income parents (n = 60) of preschool-aged children living in Philadelphia and Boston. The interview examined parents' child snacking definitions, purposes, contexts, and frequency. Verbatim transcripts were analyzed using a grounded theory approach. Coding matrices compared responses by race/ethnicity, parent education, and household food security status. Parents' commonly referenced portion sizes when describing children's snacks with phrases like "something small." Snack portion sizes were guided by considerations including healthfulness, location, hunger, and timing. Six strategies for portioning snacks were presented including use of small containers, subdividing large portions, buying prepackaged snacks, use of hand measurement, measuring cups, scales, and letting children determine portion size. Differences in considerations and strategies were seen between race/ethnic groups and by household food security status. Low-income parents of preschool-aged children described a diverse set of considerations and strategies related to portion sizes of snack foods offered to their children. Future studies should examine how these considerations and strategies influence child dietary quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Creating a measure of portion control self-efficacy.

    Science.gov (United States)

    Fast, Lindsey C; Harman, Jennifer J; Maertens, Julie A; Burnette, Jeni L; Dreith, Francesca

    2015-01-01

    Over the last few decades, food portion sizes have steadily increased by as much as 700% (Young & Nestle, 2002). Food portions are often much larger than dietary guidelines recommend, leaving individuals to manage their food consumption on their own and making it necessary to understand individual factors impacting food consumption. In the current paper, we focus on self-efficacy for portion control. Specifically, across three studies, we developed and validated a new measure of portion control self-efficacy (PCSE). The PCSE measure yielded good fit statistics and had acceptable test-retest reliability using two cross-sectional surveys (Studies 1(a) and 1(b)). Results from Study 2 demonstrated construct and predictive validity of the PCSE using the Food Amount Rating Scale (FARS; Dohm, & Striegel-Moore, 2002). Study 3 offered additional support for reliability and validity with a sample of overweight and obese adults currently trying to lose weight. Overall, findings indicate that the new PCSE measure is reliable and valid. Individuals often make inaccurate food portion estimates (Slawson & Eck, 1997; Yuhas, Bolland, & Bolland, 1989) which can lead to overeating and weight-gain. Thus, the discussion centers on the need to incorporate PCSE in future research and intervention work targeting weight loss, health, and food consumption. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Influence of nutrition labelling on food portion size consumption.

    Science.gov (United States)

    McCann, Mary T; Wallace, Julie M W; Robson, Paula J; Rennie, Kirsten L; McCaffrey, Tracy A; Welch, Robert W; Livingstone, M Barbara E

    2013-06-01

    Nutrition labelling is an important strategic approach for encouraging consumers to make healthier food choices. The availability of highly palatable foods labelled as 'low fat or reduced calorie' may encourage the over-consumption of these products. This study aimed to determine whether the manipulation of nutrition labelling information can influence food portion size consumption. Normal and overweight men (n=24) and women (n=23) were served an identical lunch meal on three separate days, but the information they received prior to consuming the lunch meal was manipulated as follows: "baseline", "high fat/energy" and "low fat/energy". Food and energy intake was significantly increased in the low fat/energy condition compared with both baseline and the high fat/energy condition. An additional 3% (162 kJ) energy was consumed by subjects under the low fat/energy condition compared to baseline. No differences were observed between the baseline and high fat/energy condition. Subjects who consumed most in the low fat/energy condition were found to be mostly men, to have a higher BMI and to be overweight. Low fat/energy information can positively influence food and energy intake, suggesting that foods labelled as 'low fat' or 'low calorie' may be one factor promoting the consumption of large food portions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Brain response to food cues varying in portion size is associated with individual differences in the portion size effect in children

    NARCIS (Netherlands)

    Keller, Kathleen L.; English, Laural K.; Fearnbach, S.N.; Lasschuijt, Marlou; Anderson, Kaitlin; Bermudez, Maria; Fisher, Jennifer O.; Rolls, Barbara J.; Wilson, Stephen J.

    2018-01-01

    Large portions promote intake of energy dense foods (i.e., the portion size effect–PSE), but the neurobiological drivers of this effect are not known. We tested the association between blood oxygen level dependent (BOLD) brain response to food images varied by portion size (PS) and energy density

  10. The Role of Social Norms in the Portion Size Effect: Reducing normative relevance reduces the effect of portion size on consumption decisions

    Directory of Open Access Journals (Sweden)

    Iris eVersluis

    2016-05-01

    Full Text Available People typically eat more from large portions of food than from small portions. An explanation that has often been given for this so-called portion size effect is that the portion size acts as a social norm and as such communicates how much is appropriate to eat. In this paper, we tested this explanation by examining whether manipulating the relevance of the portion size as a social norm changes the portion size effect, as assessed by prospective consumption decisions. We conducted one pilot experiment and one full experiment in which participants respectively indicated how much they would eat or serve themselves from a given amount of different foods. In the pilot (N = 63, we manipulated normative relevance by allegedly basing the portion size on the behavior of either students of the own university (in-group or of another university (out-group. In the main experiment (N = 321, we told participants that either a minority or majority of people similar to them approved of the portion size. Results show that in both experiments, participants expected to serve themselves and to eat more from larger than from smaller portions. As expected, however, the portion size effect was less pronounced when the reference portions were allegedly based on the behavior of an out-group (pilot or approved only by a minority (main experiment. These findings suggest that the portion size indeed provides normative information, because participants were less influenced by it if it communicated the behaviors or values of a less relevant social group. In addition, in the main experiment, the relation between portion size and the expected amount served was partially mediated by the amount that was considered appropriate, suggesting that concerns about eating an appropriate amount indeed play a role in the portion size effect. However, since the portion size effect was weakened but not eliminated by the normative relevance manipulations and since mediation was only partial

  11. How much should I eat? A comparison of suggested portion sizes in the UK.

    Science.gov (United States)

    Lewis, Hannah B; Ahern, Amy L; Jebb, Susan A

    2012-11-01

    To identify and compare suggested food portion sizes in UK schemes. The study collated and compared suggested portion sizes from selected UK schemes intended both for general advice and weight-loss advice. Portion size schemes were included if they were relevant to the UK, provided actual portion size information, were intended for adults and were obtainable from the public domain in November 2010. Included schemes were from the food industry, non-governmental organisations and health-care professionals. Suggested portion sizes of foods occurring in at least one scheme for general advice and at least one scheme for weight loss were included. Own brand on-pack portion size labelling from a large UK-wide supermarket was added to represent portion size advice from UK food retailers. Not applicable. The suggested portion sizes in the weight-loss advice schemes were often concordant, as were the general advice schemes, except one general advice scheme from a non-governmental organisation which was more closely aligned with the portion sizes for weight loss. Overall there were substantial discrepancies between suggested portion sizes for muesli and crunchy breakfast cereals, rice, pasta and potatoes, meat, fish and pulses, whereas portion sizes for cooked vegetables, dried fruit, some breakfast cereals and cheese were broadly consistent. There is a lack of consistency in the portion sizes communicated to the public. An independent and authoritative scheme of suggested portion sizes for all foods, with distinct recommendations for general advice and for weight-loss advice, could be of benefit.

  12. How much should I eat? A comparison of suggested portion sizes in the UK

    OpenAIRE

    Lewis, Hannah B; Ahern, Amy L; Jebb, Susan A

    2012-01-01

    Objective To identify and compare suggested food portion sizes in UK schemes. Design The study collated and compared suggested portion sizes from selected UK schemes intended both for general advice and weight-loss advice. Setting Portion size schemes were included if they were relevant to the UK, provided actual portion size information, were intended for adults and were obtainable from the public domain in November 2010. Included schemes were from the food industry, non-governmental organis...

  13. Small, medium, large or supersize? The development and evaluation of interventions targeted at portion size

    Science.gov (United States)

    Vermeer, W M; Steenhuis, I H M; Poelman, M P

    2014-01-01

    In the past decades, portion sizes of high-caloric foods and drinks have increased and can be considered an important environmental obesogenic factor. This paper describes a research project in which the feasibility and effectiveness of environmental interventions targeted at portion size was evaluated. The studies that we conducted revealed that portion size labeling, offering a larger variety of portion sizes, and proportional pricing (that is, a comparable price per unit regardless of the size) were considered feasible to implement according to both consumers and point-of-purchase representatives. Studies into the effectiveness of these interventions demonstrated that the impact of portion size labeling on the (intended) consumption of soft drinks was, at most, modest. Furthermore, the introduction of smaller portion sizes of hot meals in worksite cafeterias in addition to the existing size stimulated a moderate number of consumers to replace their large meals by a small meal. Elaborating on these findings, we advocate further research into communication and marketing strategies related to portion size interventions; the development of environmental portion size interventions as well as educational interventions that improve people's ability to deal with a ‘super-sized' environment; the implementation of regulation with respect to portion size labeling, and the use of nudges to stimulate consumers to select healthier portion sizes. PMID:25033959

  14. A qualitative study of parents’ perceptions and use of portion size strategies for preschool children’s snacks

    Science.gov (United States)

    Blake, Christine E.; Fisher, Jennifer Orlet; Ganter, Claudia; Younginer, Nicholas; Orloski, Alexandria; Blaine, Rachel E.; Bruton, Yasmeen; Davison, Kirsten K.

    2014-01-01

    Objective Increases in childhood obesity correspond with shifts in children’s snacking behaviors and food portion sizes. This study examined parents’ conceptualizations of portion size and the strategies they use to portion snacks in the context of preschool-aged children’s snacking. Methods Semi-structured qualitative interviews were conducted with non-Hispanic white (W), African American (AA), and Hispanic (H) low-income parents (n=60) of preschool-aged children living in Philadelphia and Boston. The interview examined parents’ child snacking definitions, purposes, contexts, and frequency. Verbatim transcripts were analyzed using a grounded theory approach. Coding matrices compared responses by race/ethnicity, parent education, and household food security status. Results Parents’ commonly referenced portion sizes when describing children’s snacks with phrases like “something small.” Snack portion sizes were guided by considerations including healthfulness, location, hunger, and timing. Six strategies for portioning snacks were presented including use of small containers, subdividing large portions, buying prepackaged snacks, use of hand measurement, measuring cups, scales, and letting children determine portion size. Differences in considerations and strategies were seen between race/ ethnic groups and by household food security status. Conclusions Low-income parents of preschool-aged children described a diverse set of considerations and strategies related to portion sizes of snack foods offered to their children. Future studies should examine how these considerations and strategies influence child dietary quality. PMID:25447008

  15. Acute sleep deprivation increases portion size and affects food choice in young men.

    Science.gov (United States)

    Hogenkamp, Pleunie S; Nilsson, Emil; Nilsson, Victor C; Chapman, Colin D; Vogel, Heike; Lundberg, Lina S; Zarei, Sanaz; Cedernaes, Jonathan; Rångtell, Frida H; Broman, Jan-Erik; Dickson, Suzanne L; Brunstrom, Jeffrey M; Benedict, Christian; Schiöth, Helgi B

    2013-09-01

    Acute sleep loss increases food intake in adults. However, little is known about the influence of acute sleep loss on portion size choice, and whether this depends on both hunger state and the type of food (snack or meal item) offered to an individual. The aim of the current study was to compare portion size choice after a night of sleep and a period of nocturnal wakefulness (a condition experienced by night-shift workers, e.g. physicians and nurses). Sixteen men (age: 23 ± 0.9 years, BMI: 23.6 ± 0.6 kg/m(2)) participated in a randomized within-subject design with two conditions, 8-h of sleep and total sleep deprivation (TSD). In the morning following sleep interventions, portion size, comprising meal and snack items, was measured using a computer-based task, in both fasted and sated state. In addition, hunger as well as plasma levels of ghrelin were measured. In the morning after TSD, subjects had increased plasma ghrelin levels (13%, p=0.04), and chose larger portions (14%, p=0.02), irrespective of the type of food, as compared to the sleep condition. Self-reported hunger was also enhanced (pchoice after sleep loss depend on both an individual's hunger status, and the type of food offered. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Developing an interactive portion size assessment system (IPSAS) for use with children.

    Science.gov (United States)

    Foster, E; Hawkins, A; Simpson, E; Adamson, A J

    2014-01-01

    Novel methods of assessing dietary intake are required to reduce the participant burden in dietary surveys, improve participation rates and thereby improve the representativeness of the sample and minimise the impact of measuring dietary intake on a subject's food intake during the recording period. One method of reducing the burden placed on participants in recording dietary intake is to replace weighing of foods with estimation of portion size using tools such as food photographs. The interactive portion size assessment system (IPSAS) is an interactive portion size assessment system for use in assessing portion sizes of foods consumed by children aged 18 months to 16 years. The system is computer-based and is designed to be administered during an interview for a food diary or 24-h recall. The portion sizes depicted are age-specific and based on the weights of foods served to children during the UK National Diet and Nutrition Surveys. The system displays digital images of food used to estimate the amount of each food served to the child and the amount of any food left over. Foods are categorised within the system using a three-tier structure. Twenty-seven food group icons are used with two further drop-down menus to select first the food group, then the food category and, finally, the actual food product. Each food is linked to UK food composition codes and all photographs are linked to the weight of the food depicted. Nutritional output is via a companion database. The present study describes the development of the IPSAS and the structure of the system. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  17. Value for money or making the healthy choice: the impact of proportional pricing on consumers' portion size choices.

    Science.gov (United States)

    Vermeer, Willemijn M; Alting, Esther; Steenhuis, Ingrid H M; Seidell, Jacob C

    2010-02-01

    Large food portion sizes are determinants of a high caloric intake, especially if they have been made attractive through value size pricing (i.e. lower unit prices for large than for small portion sizes). The purpose of the two questionnaire studies that are reported in this article was to assess the impact of proportional pricing (i.e. removing beneficial prices for large sizes) on people's portion size choices of high caloric food and drink items. Both studies employed an experimental design with a proportional pricing condition and a value size pricing condition. Study 1 was conducted in a fast food restaurant (N = 150) and study 2 in a worksite cafeteria (N = 141). Three different food products (i.e. soft drink, chicken nuggets in study 1 and a hot meal in study 2) with corresponding prices were displayed on pictures in the questionnaire. Outcome measures were consumers' intended portion size choices. No main effects of pricing were found. However, confronted with proportional pricing a trend was found for overweight fast food restaurant visitors being more likely to choose small portion sizes of chicken nuggets (OR = 4.31, P = 0.07) and less likely to choose large soft drink sizes (OR = 0.07, P = 0.04). Among a general public, proportional pricing did not reduce consumers' size choices. However, pricing strategies can help overweight and obese consumers selecting appropriate portion sizes of soft drink and high caloric snacks. More research in realistic settings with actual behaviour as outcome measure is required.

  18. Food photography. I: The perception of food portion size from photographs.

    Science.gov (United States)

    Nelson, M; Atkinson, M; Darbyshire, S

    1994-11-01

    Fifty-one male and female volunteers aged 18-90 years from a wide variety of social and occupational backgrounds completed 7284 assessments of portion size in relation to food photographs. Subjects were shown six portion sizes (two small, two medium and two large) for each of six foods, and asked to compare the amount on the plate in front of them to (a) a series of eight photographs showing weights of portions from the 5th to the 95th centile of portion size (British Adult Dietary Survey), or (b) a single photograph of the average (median) portion size. Photographs were prepared either in colour or in black and white, and in two different sizes. The order of presentation of foods; use of black and white or colour; the size of photographs; and presentation of eight or average photographs were each randomized independently. On average, the mean differences between the portion size presented and the estimate of portion size using the photographs varied from -8 to +6 g (-4 to +5%) for the series of eight photographs, and from -34 to -1 g (-23 to +9%) for the single average photograph. Large portion sizes tended to be underestimated more than medium or small portion sizes, especially when using the average photograph (from -79 to -14 g, -37 to -13%). Being female, 65 years and over, or retired, or seeing photographs in colour, were all associated with small but statistically significant overestimations of portion size. Having a body mass index > or = 30 kg/m2 was associated with an 8% underestimate of portion size. We conclude that use of a series of eight photographs is associated with relatively small errors in portion size perception, whereas use of an average photograph is consistently associated with substantial underestimation across a variety of foods.

  19. Comparison of known food weights with image-based portion-size automated estimation and adolescents' self-reported portion size.

    Science.gov (United States)

    Lee, Christina D; Chae, Junghoon; Schap, TusaRebecca E; Kerr, Deborah A; Delp, Edward J; Ebert, David S; Boushey, Carol J

    2012-03-01

    Diet is a critical element of diabetes self-management. An emerging area of research is the use of images for dietary records using mobile telephones with embedded cameras. These tools are being designed to reduce user burden and to improve accuracy of portion-size estimation through automation. The objectives of this study were to (1) assess the error of automatically determined portion weights compared to known portion weights of foods and (2) to compare the error between automation and human. Adolescents (n = 15) captured images of their eating occasions over a 24 h period. All foods and beverages served were weighed. Adolescents self-reported portion sizes for one meal. Image analysis was used to estimate portion weights. Data analysis compared known weights, automated weights, and self-reported portions. For the 19 foods, the mean ratio of automated weight estimate to known weight ranged from 0.89 to 4.61, and 9 foods were within 0.80 to 1.20. The largest error was for lettuce and the most accurate was strawberry jam. The children were fairly accurate with portion estimates for two foods (sausage links, toast) using one type of estimation aid and two foods (sausage links, scrambled eggs) using another aid. The automated method was fairly accurate for two foods (sausage links, jam); however, the 95% confidence intervals for the automated estimates were consistently narrower than human estimates. The ability of humans to estimate portion sizes of foods remains a problem and a perceived burden. Errors in automated portion-size estimation can be systematically addressed while minimizing the burden on people. Future applications that take over the burden of these processes may translate to better diabetes self-management. © 2012 Diabetes Technology Society.

  20. A qualitative study of psychological, social and behavioral barriers to appropriate food portion size control.

    Science.gov (United States)

    Spence, Michelle; Livingstone, M Barbara E; Hollywood, Lynsey E; Gibney, Eileen R; O'Brien, Sinéad A; Pourshahidi, L Kirsty; Dean, Moira

    2013-08-01

    Given the worldwide prevalence of overweight and obesity, there is a clear need for meaningful practical healthy eating advice - not only in relation to food choice, but also on appropriate food portion sizes. As the majority of portion size research to date has been overwhelmingly quantitative in design, there is a clear need to qualitatively explore consumers' views in order to fully understand how food portion size decisions are made. Using qualitative methodology this present study aimed to explore consumers' views about factors influencing their portion size selection and consumption and to identify barriers to appropriate portion size control. Ten focus groups with four to nine participants in each were formed with a total of 66 persons (aged 19-64 years) living on the island of Ireland. The semi-structured discussions elicited participants' perceptions of suggested serving size guidance and explored the influence of personal, social and environmental factors on their food portion size consumption. Audiotapes of the discussions were professionally transcribed verbatim, loaded into NVivo 9, and analysed using an inductive thematic analysis procedure. The rich descriptive data derived from participants highlight that unhealthy portion size behaviors emanate from various psychological, social and behavioral factors. These bypass reflective and deliberative control, and converge to constitute significant barriers to healthy portion size control. Seven significant barriers to healthy portion size control were apparent: (1) lack of clarity and irrelevance of suggested serving size guidance; (2) guiltless eating; (3) lack of self-control over food cues; (4) distracted eating; (5) social pressures; (6) emotional eating rewards; and (7) quantification habits ingrained from childhood. Portion size control strategies should empower consumers to overcome these effects so that the consumption of appropriate food portion sizes becomes automatic and habitual.

  1. The effect of portion size on food intake is robust to brief education and mindfulness exercises.

    Science.gov (United States)

    Cavanagh, Karen; Vartanian, Lenny R; Herman, C Peter; Polivy, Janet

    2014-06-01

    We examined whether a brief education and a brief mindfulness exercise would reduce the effect of portion size on food intake. Participants were randomly assigned to one of the three information conditions (education, mindfulness, or control) and then received a small or large portion of pasta for lunch. Neither education nor mindfulness was effective in reducing the effect of portion size: Overall, participants served a large portion consumed 34 percent more pasta than did those served a small portion. Participants in the mindfulness condition tended to eat less overall than participants did in the two other conditions, but this trend was not significant. © The Author(s) 2013.

  2. Eating Habits, Nutritional Status and Portion Sizes in the Elderly ...

    African Journals Online (AJOL)

    admpather

    status using anthropometric measurements such as weight and height, ... The interview was carried out face to face. ... study showed that the nutritional status of the elderly population as assessed by ..... Several cross-sectional studies .... fruit and vegetables intakes between children of Dutch origin and non-Western ethnic.

  3. Portion size effects on daily energy intake in low-income Hispanic and African American children and their mothers.

    Science.gov (United States)

    Fisher, Jennifer O; Arreola, Angeles; Birch, Leann L; Rolls, Barbara J

    2007-12-01

    Portion size influences children's energy intakes at meals, but effects on daily intake are unknown. Effects of large portions on daily energy intake were tested in 5-y-old Hispanic and African American children from low-income families. Maternal food intake data were collected to evaluate familial susceptibility to portion size. A within-subjects experimental design with reference and large portion sizes was used in a study of 59 low-income Hispanic and African American preschool-aged children and their mothers. The portion size of 3 entrées (lunch, dinner, and breakfast) and an afternoon snack served during a 24-h period were of a reference size in one condition and doubled in the other condition. Portion sizes of other foods and beverages did not vary across conditions. Weighed food intake, anthropometric measures, and self-reported data were obtained. Doubling the portion size of several entrées and a snack served during a 24-h period increased energy intake from those foods by 23% (180 kcal) among children (P kcal) among mothers (P daily intakes among Hispanic and African American children.

  4. Obese and overweight individuals are less sensitive to information about meal times in portion size judgements.

    Science.gov (United States)

    Zimmerman, A R; Mason, A; Rogers, P J; Brunstrom, J M

    2017-11-16

    Obesity is related to a tendency to discount the future. Information regarding inter-meal interval (IMI) allows meal planning. We sought to assess how obese, overweight, and lean people select portion sizes based on the length of an IMI. We hypothesised that individuals with a high BMI would discount information about the IMI. In addition, we investigated how reduced sensitivity to IMIs relates to monetary temporal discounting. Participants (lean, n=35; overweight, n=31; obese, n=22), selected lunchtime portion sizes in response to information about the timings of their next meal. In seven trials, the time of the IMI was systematically manipulated, ranging from 'right now' to '8 h'. Participants then completed a monetary temporal discounting task. BMI was included as a continuous measure. For each participant, we conducted a linear regression of portion size on IMI to yield a gradient that reflected reduced sensitivity to future meal timings. As expected, participants selected larger portion sizes in response to a long IMI. Consistent with our hypothesis, individuals with a high BMI discounted information about the IMI (β=-3.49, P=0.015; confidence interval (CI) 6.29 to -0.70). Monetary discounting also negatively predicted BMI (β=-8.1, P=0.003; CI=-13.43 to -2.77), but did not correlate with IMI sensitivity (P>0.05). These results are the first to demonstrate that temporal discounting operates in planning from one meal to the next, and is more prevalent in obese and overweight, relative to lean individuals. Participants with a high BMI discounted concerns about potential future fullness and hunger in the IMI. Our observations might begin to explain associations between obesity and irregular meal timings or help to form the basis for a targeted intervention that promotes future thinking in meal planning.International Journal of Obesity accepted article preview online, 16 November 2017. doi:10.1038/ijo.2017.275.

  5. Menu-engineering in restaurants - adapting portion sizes on plates to enhance vegetable consumption

    NARCIS (Netherlands)

    Reinders, Machiel J.; Huitink, Marlijn; Dijkstra, S.C.; Maaskant, Anna J.; Heijnen, Joris

    2017-01-01

    Background: The aim of this research was to investigate whether increased portion sizes of vegetables and decreased portion sizes of meat on main dishes increased the amount of vegetables consumed in a real-life restaurant setting without affecting customer satisfaction. The participants were

  6. Adaptation of Locally Available Portion Sizes for Food Frequency Questionnaires in Nutritional Epidemiological Studies: How Much Difference does it Make?

    Science.gov (United States)

    Gupta, Neha; Verma, Sonika; Singh, Abhishek; Tandon, Nikhil; Puri, Seema; Arora, Narendra Kumar

    2016-01-01

    There is need for employing strategies to minimize measurement errors while administering semi-quantitative FFQ. The current study was planned to adapt and standardize locally available portion sizes for semi-quantitative FFQ to improve its validity and document the process of standardization of portion sizes. The study was conducted in 9 villages of the INCLEN-SOMAARTH DDESS (Demographic, Development and Environmental Surveillance Site), Palwal district, Haryana, India. The subjects in these nine villages are part of a cohort study to assess the interaction between societal and household factors with food intake and physical activity of children. Systematic utensil survey was undertaken in 3 randomly chosen households per village i.e. 27 households and the portion sizes were derived from a total of 74 serving utensils. The derived sizes were classified as small (240 ml), medium (320 ml) and large (600 ml). The semi-quantitative FFQ with locally derived portion sizes was then administered to 63 children in 6-12 year age group. The volume of food measured by the reference portion sizes generally being employed in the national surveys, would have been underestimated the food consumed by the child by 55-60% as compared to what was being consumed by the children in the study area. The correlation between food intake assessed by 24-hr recall method and FFQ using derived (local) portion sizes was better as compared to that obtained with the semi-quantitative FFQ done with reference portions. In conclusion, local portion size adaptation of FFQ for semi-quantification is useful to mitigate measurement errors associated with this technique.

  7. Eating patterns and portion size associated with obesity in a Swedish population.

    Science.gov (United States)

    Berg, Christina; Lappas, Georgios; Wolk, Alicja; Strandhagen, Elisabeth; Torén, Kjell; Rosengren, Annika; Thelle, Dag; Lissner, Lauren

    2009-02-01

    The objective of this study was to describe the association between meal pattern and obesity. The study is based on data from the INTERGENE research programme, and the study population consists of randomly selected women and men, aged 25-74, living in the Västra Götaland Region in Sweden. A total of 3610 were examined. Participants with measured BMI> or =30 were compared with others (BMIportions. Odds ratios (OR) with 95% confidence intervals were adjusted for age, sex, smoking and physical activity in logistic regression models. Being obese was significantly associated with omitting breakfast, OR 1.41 (1.05-1.90), omitting lunch OR 1.31 (1.04-1.66) and eating at night OR 1.62 (1.10-2.39). Obesity was also related to significantly larger self-reported portion sizes of main meals. No statistically significant relationship with intake of total energy was revealed. Thus, the results indicate that examination of meal patterns and portion sizes might tell us more about obesogenic food patterns than traditional nutrient analyses of food frequencies. Being obese was associated with a meal pattern shifted to later in the day and significantly larger self-reported portions of main meals.

  8. The influence of front-of-pack nutrition information on consumers' portion size perceptions.

    Science.gov (United States)

    Brown, Hannah May; de Vlieger, Nienke; Collins, Clare; Bucher, Tamara

    2017-08-01

    Issue addressed Portion size guidance strategies have been suggested as an important component of weight management; therefore, the Health Star Rating (HSR) front-of-pack labels could influence consumers' portion-size decisions. However, this has not been investigated to date. This study aims to evaluate whether presenting energy content information and HSRs influences portion size self-selection of specific foods and meals. Methods Adults were randomly assigned to one of three experimental groups in this randomised controlled experiment. Each participant was given either a kJ/100g food label or a HSR label, or was given no information on nutrient composition. They were then asked to serve themselves an adequate portion of breakfast cereal (Kellogg's Nutri-Grain), fruit salad and chocolate, plus a three-component meal (chicken, fries and mixed vegetables). Portion serves and meal weights were compared between each experimental group using ANOVA and the discretionary foods were also compared with the Australian Guide to Healthy Eating (AGHE). Results Neither the kilojoule nor HSR information influenced the self-served portion size of foods or meal components. Mean self-served portion size of the discretionary foods were significantly greater than the standard serving sizes as specified in the AGHE. Conclusion Although food labels have the potential to assist consumers in making product choices, this study indicates that presenting nutrition information does not affect portion size decisions in young adults. So what? Strategies that assist consumers to choose appropriate portion sizes should be developed as a weight management tool.

  9. An evaluation of portion size estimation aids: Consumer perspectives on their effectiveness.

    Science.gov (United States)

    Faulkner, Gemma P; Livingstone, M Barbara E; Pourshahidi, L Kirsty; Spence, Michelle; Dean, Moira; O'Brien, Sinead; Gibney, Eileen R; Wallace, Julie M W; McCaffrey, Tracy A; Kerr, Maeve A

    2017-07-01

    This qualitative study aimed to investigate consumer opinions on the usefulness of portion size estimation aids (PSEA); consumer preferences in terms of format and context for use; and the level of detail of guidance considered necessary for the effective application of PSEA. Six focus groups (three to eight participants per group) were conducted to elicit views on PSEA. The discussions were recorded, transcribed verbatim and analysed by two independent researchers using a template approach. The focus groups were conducted in 2013 by an experienced moderator in various sites across the island of Ireland (three in the Republic of Ireland and three in Northern Ireland) including local leisure, community and resource centres; the home environment; and a university meeting room. General population, males (n = 17) and females (n = 15) aged 18-64 years old. Participants were recruited from both urban and rural locations representing a range of socio-economic groups. The majority of participants deemed the coloured portion pots and disposable plastic cup (household measures) to be useful particularly for the estimation of amorphous cereal products (e.g. breakfast cereals). Preferences were evident for "visual" PSEA (reference objects, household measures and food packaging) rather than 'quantities and measures' such as weighing in grams or ounces. Participants stated that PS education should be concise, consistent, from a reputable source, initiated at school age and communicated innovatively e.g. mobile app or TV advertisement. Guidance in relation to gender, age and activity level was favoured over a "one size fits all" approach. This study identified consumer preferences and acceptance of "visual" PSEA such as portion pots/cups to estimate appropriate PS of amorphous grain foods such as breakfast cereals, pasta and rice. Concise information from a reputable source in relation to gender, age and activity level should accompany PSEA. Copyright © 2017 Elsevier Ltd

  10. Association between excess weight and beverage portion size consumed in Brazil

    Directory of Open Access Journals (Sweden)

    Ilana Nogueira Bezerra

    2018-02-01

    Full Text Available ABSTRACT OBJECTIVE To describe the beverage portion size consumed and to evaluate their association with excess weight in Brazil. METHODS We used data from the National Dietary Survey, which included individuals with two days of food record aged over 20 years (n = 24,527 individuals. The beverages were categorized into six groups: soft drink, 100% fruit juice, fruit drink, alcoholic beverage, milk, and coffee or tea. We estimated the average portion consumed for each group and we evaluated, using linear regression, the association between portion size per group and the variables of age, sex, income, and nutritional status. We tested the association between portion size and excess weight using Poisson regression, adjusted for age, sex, income, and total energy intake. RESULTS The most frequently consumed beverages in Brazil were coffee and tea, followed by 100% fruit juices, soft drinks, and milk. Alcoholic beverages presented the highest average in the portion size consumed, followed by soft drinks, 100% fruit juice, fruit drink, and milk. Portion size showed positive association with excess weight only in the soft drink (PR = 1.19, 95%CI 1.10–1.27 and alcoholic beverage groups (PR = 1.20, 95%CI, 1.11–1.29, regardless of age, sex, income, and total energy intake. CONCLUSIONS Alcoholic beverages and soft drinks presented the highest averages in portion size and positive association with excess weight. Public health interventions should address the issue of portion sizes offered to consumers by discouraging the consumption of large portions, especially sweetened and low nutritional beverages.

  11. Portion, package or tableware size for changing selection and consumption of food, alcohol and tobacco.

    Science.gov (United States)

    Hollands, Gareth J; Shemilt, Ian; Marteau, Theresa M; Jebb, Susan A; Lewis, Hannah B; Wei, Yinghui; Higgins, Julian P T; Ogilvie, David

    2015-09-14

    Overeating and harmful alcohol and tobacco use have been linked to the aetiology of various non-communicable diseases, which are among the leading global causes of morbidity and premature mortality. As people are repeatedly exposed to varying sizes and shapes of food, alcohol and tobacco products in environments such as shops, restaurants, bars and homes, this has stimulated public health policy interest in product size and shape as potential targets for intervention. 1) To assess the effects of interventions involving exposure to different sizes or sets of physical dimensions of a portion, package, individual unit or item of tableware on unregulated selection or consumption of food, alcohol or tobacco products in adults and children.2) To assess the extent to which these effects may be modified by study, intervention and participant characteristics. We searched CENTRAL, MEDLINE, EMBASE, PsycINFO, eight other published or grey literature databases, trial registries and key websites up to November 2012, followed by citation searches and contacts with study authors. This original search identified eligible studies published up to July 2013, which are fully incorporated into the review. We conducted an updated search up to 30 January 2015 but further eligible studies are not yet fully incorporated due to their minimal potential to change the conclusions. Randomised controlled trials with between-subjects (parallel-group) or within-subjects (cross-over) designs, conducted in laboratory or field settings, in adults or children. Eligible studies compared at least two groups of participants, each exposed to a different size or shape of a portion of a food (including non-alcoholic beverages), alcohol or tobacco product, its package or individual unit size, or of an item of tableware used to consume it, and included a measure of unregulated selection or consumption of food, alcohol or tobacco. We applied standard Cochrane methods to select eligible studies for inclusion and

  12. A Qualitative Study of Soldier Perceptions of the Relative Importance of MRE Portion Size and Variety

    National Research Council Canada - National Science Library

    Bell, R

    1999-01-01

    .... Bliss, Biggs Army Airfield, and Fort Leonard Wood during 1997 to understand how soldiers perceive Meal, Ready-to-Eat portion size and MRE variety and to begin to determine what types of trade offs...

  13. Formative evaluation of a mobile liquid portion size estimation interface for people with varying literacy skills.

    Science.gov (United States)

    Chaudry, Beenish Moalla; Connelly, Kay; Siek, Katie A; Welch, Janet L

    2013-12-01

    Chronically ill people, especially those with low literacy skills, often have difficulty estimating portion sizes of liquids to help them stay within their recommended fluid limits. There is a plethora of mobile applications that can help people monitor their nutritional intake but unfortunately these applications require the user to have high literacy and numeracy skills for portion size recording. In this paper, we present two studies in which the low- and the high-fidelity versions of a portion size estimation interface, designed using the cognitive strategies adults employ for portion size estimation during diet recall studies, was evaluated by a chronically ill population with varying literacy skills. The low fidelity interface was evaluated by ten patients who were all able to accurately estimate portion sizes of various liquids with the interface. Eighteen participants did an in situ evaluation of the high-fidelity version incorporated in a diet and fluid monitoring mobile application for 6 weeks. Although the accuracy of the estimation cannot be confirmed in the second study but the participants who actively interacted with the interface showed better health outcomes by the end of the study. Based on these findings, we provide recommendations for designing the next iteration of an accurate and low literacy-accessible liquid portion size estimation mobile interface.

  14. Improving accuracy of portion-size estimations through a stimulus equivalence paradigm.

    Science.gov (United States)

    Hausman, Nicole L; Borrero, John C; Fisher, Alyssa; Kahng, SungWoo

    2014-01-01

    The prevalence of obesity continues to increase in the United States (Gordon-Larsen, The, & Adair, 2010). Obesity can be attributed, in part, to overconsumption of energy-dense foods. Given that overeating plays a role in the development of obesity, interventions that teach individuals to identify and consume appropriate portion sizes are warranted. Specifically, interventions that teach individuals to estimate portion sizes correctly without the use of aids may be critical to the success of nutrition education programs. The current study evaluated the use of a stimulus equivalence paradigm to teach 9 undergraduate students to estimate portion size accurately. Results suggested that the stimulus equivalence paradigm was effective in teaching participants to make accurate portion size estimations without aids, and improved accuracy was observed in maintenance sessions that were conducted 1 week after training. Furthermore, 5 of 7 participants estimated the target portion size of novel foods during extension sessions. These data extend existing research on teaching accurate portion-size estimations and may be applicable to populations who seek treatment (e.g., overweight or obese children and adults) to teach healthier eating habits. © Society for the Experimental Analysis of Behavior.

  15. News Media Framing of New York City's Sugar-Sweetened Beverage Portion-Size Cap.

    Science.gov (United States)

    Donaldson, Elisabeth A; Cohen, Joanna E; Truant, Patricia L; Rutkow, Lainie; Kanarek, Norma F; Barry, Colleen L

    2015-11-01

    We assessed news media framing of New York City's proposed regulation to prohibit the sale of sugar-sweetened beverages greater than 16 ounces. We conducted a quantitative content analysis of print and television news from within and outside New York City media markets. We examined support for and opposition to the portion-size cap in the news coverage from its May 31, 2012, proposal through the appellate court ruling on July 31, 2013. News coverage corresponded to key events in the policy's evolution. Although most stories mentioned obesity as a problem, a larger proportion used opposing frames (84%) than pro-policy frames (36%). Mention of pro-policy frames shifted toward the policy's effect on special populations. The debate's most prominent frame was the opposing frame that the policy was beyond the government's role (69%). News coverage within and outside the New York City media market was more likely to mention arguments in opposition to than in support of the portion-size cap. Understanding how the news media framed this issue provides important insights for advocates interested in advancing similar measures in other jurisdictions.

  16. Association of Overweight with Food Portion Size among Adults of São Paulo - Brazil.

    Directory of Open Access Journals (Sweden)

    Jaqueline Lopes Pereira

    Full Text Available Although studies show that portion size affects energy intake, few have demonstrated a link between portion size and weight status, especially in free-living populations. The objective of the present study was to assess the relationship between food portion sizes and overweight in a representative population of adults of São Paulo, Brazil.Cross-sectional population-based study with 1005 adults from São Paulo, Brazil. Dietary data were obtained from two 24-hour recalls. Reported foods were classified into groups and energy contribution, prevalence of consumers and portion sizes were calculated. Individuals were classified according to BMI in with and without overweight. Logistic regression models were used to evaluate the association between food portion sizes and being overweight.The most consumed food groups were: beans, breads/rolls, coffee/tea, milk, rice, and sugar. Rice, red meat, breads/rolls, and white meat were the groups with the highest percentage of contribution to total energy intake. Butter/margarine, toasts/biscuits, sugar, and cakes were the groups with the highest energy density. After adjustment for confounding variables, overweight was associated with larger portions of pizza (OR = 1.052; p = 0.048, red meat (OR = 1.025; p = 0.043, rice (OR = 1.033; p<0.001, salted snacks (OR = 1.078; p = 0.022, and soft drinks (OR = 1.016; p = 0.007.Larger portions of few food groups with different energy densities were associated with being overweight, suggesting that overweight may be related to the consumption of larger portion sizes of a series of food groups, not a food group alone. Additionally, we highlight the importance of considering underreporting as a confounding factor in these associations.

  17. Development of an online database of typical food portion sizes in Irish population groups.

    Science.gov (United States)

    Lyons, Jacqueline; Walton, Janette; Flynn, Albert

    2013-01-01

    The Irish Food Portion Sizes Database (available at www.iuna.net) describes typical portion weights for an extensive range of foods and beverages for Irish children, adolescents and adults. The present paper describes the methodologies used to develop the database and some key characteristics of the portion weight data contained therein. The data are derived from three large, cross-sectional food consumption surveys carried out in Ireland over the last decade: the National Children's Food Survey (2003-2004), National Teens' Food Survey (2005-2006) and National Adult Nutrition Survey (2008-2010). Median, 25th and 75th percentile portion weights are described for a total of 545 items across the three survey groups, split by age group or sex as appropriate. The typical (median) portion weights reported for adolescents and adults are similar for many foods, while those reported for children are notably smaller. Adolescent and adult males generally consume larger portions than their female counterparts, though similar portion weights may be consumed where foods are packaged in unit amounts (for example, pots of yoghurt). The inclusion of energy under-reporters makes little difference to the estimation of typical portion weights in adults. The data have wide-ranging applications in dietary assessment and food labelling, and will serve as a useful reference against which to compare future portion size data from the Irish population. The present paper provides a useful context for researchers and others wishing to use the Irish Food Portion Sizes Database, and may guide researchers in other countries in establishing similar databases of their own.

  18. Portion, package or tableware size for changing selection and consumption of food, alcohol and tobacco

    Science.gov (United States)

    Hollands, Gareth J; Shemilt, Ian; Marteau, Theresa M; Jebb, Susan A; Lewis, Hannah B; Wei, Yinghui; Higgins, Julian Pt; Ogilvie, David

    2015-01-01

    Background Overeating and harmful alcohol and tobacco use have been linked to the aetiology of various non-communicable diseases, which are among the leading global causes of morbidity and premature mortality. As people are repeatedly exposed to varying sizes and shapes of food, alcohol and tobacco products in environments such as shops, restaurants, bars and homes, this has stimulated public health policy interest in product size and shape as potential targets for intervention. Objectives 1) To assess the effects of interventions involving exposure to different sizes or sets of physical dimensions of a portion, package, individual unit or item of tableware on unregulated selection or consumption of food, alcohol or tobacco products in adults and children. 2) To assess the extent to which these effects may be modified by study, intervention and participant characteristics. Search methods We searched CENTRAL, MEDLINE, EMBASE, PsycINFO, eight other published or grey literature databases, trial registries and key websites up to November 2012, followed by citation searches and contacts with study authors. This original search identified eligible studies published up to July 2013, which are fully incorporated into the review. We conducted an updated search up to 30 January 2015 but further eligible studies are not yet fully incorporated due to their minimal potential to change the conclusions. Selection criteria Randomised controlled trials with between-subjects (parallel-group) or within-subjects (cross-over) designs, conducted in laboratory or field settings, in adults or children. Eligible studies compared at least two groups of participants, each exposed to a different size or shape of a portion of a food (including non-alcoholic beverages), alcohol or tobacco product, its package or individual unit size, or of an item of tableware used to consume it, and included a measure of unregulated selection or consumption of food, alcohol or tobacco. Data collection and

  19. PortionControl@HOME: Results of a Randomized Controlled Trial Evaluating the Effect of a Multi-Component Portion Size Intervention on Portion Control Behavior and Body Mass Index

    NARCIS (Netherlands)

    Poelman, M.P.; Vet, de E.; Velema, E.; Boer, de M.R.; Seidell, J.C.; Steenhuis, I.H.M.

    2015-01-01

    Background Food portion sizes influence energy intake. Purpose The purpose of this paper is to determine effectiveness of the “PortionControl@HOME” intervention on body mass index and portion control behavior. Methods A randomized controlled trial among 278 overweight and obese participants was

  20. Encouraging vegetable intake as a snack among children: the influence of portion and unit size

    NARCIS (Netherlands)

    Kleef, van E.; Bruggers, I.; Vet, de E.

    2015-01-01

    OBJECTIVE: People eat more unhealthy foods when served more (portion size effect) and when the food is served in larger units (unit size effect). The present study aimed to examine whether these effects can be used for the good: to increase vegetable consumption among children. DESIGN: A 2×2

  1. Small portion sizes in worksite cafeterias: do they help consumers to reduce their food intake?

    NARCIS (Netherlands)

    Vermeer, W.M.; Steenhuis, I.H.M.; Leeuwis, F.H.; Heijmans, M.W.; Seidell, J.C.

    2011-01-01

    Background:Environmental interventions directed at portion size might help consumers to reduce their food intake.Objective:To assess whether offering a smaller hot meal, in addition to the existing size, stimulates people to replace their large meal with a smaller meal.Design:Longitudinal randomized

  2. Validation of a food quantification picture book and portion sizes estimation applying perception and memory methods.

    Science.gov (United States)

    Szenczi-Cseh, J; Horváth, Zs; Ambrus, Á

    2017-12-01

    We tested the applicability of EPIC-SOFT food picture series used in the context of a Hungarian food consumption survey gathering data for exposure assessment, and investigated errors in food portion estimation resulted from the visual perception and conceptualisation-memory. Sixty-two participants in three age groups (10 to foods. The results were considered acceptable if the relative difference between average estimated and actual weight obtained through the perception method was ≤25%, and the relative standard deviation of the individual weight estimates was food items were rated acceptable. Small portion sizes were tended to be overestimated, large ones were tended to be underestimated. Portions of boiled potato and creamed spinach were all over- and underestimated, respectively. Recalling the portion sizes resulted in overestimation with larger differences (up to 60.7%).

  3. Increasing portion sizes of fruits and vegetables in an elementary school lunch program can increase fruit and vegetable consumption.

    Science.gov (United States)

    Miller, Nicole; Reicks, Marla; Redden, Joseph P; Mann, Traci; Mykerezi, Elton; Vickers, Zata

    2015-08-01

    Increasing portion size can increase children's consumption of food. The goal of this study was to determine whether increasing the portion sizes of fruits and vegetables in an elementary school cafeteria environment would increase children's consumption of them. We measured each child's consumption of the fruit and vegetables served in a cafeteria line on a control day (normal cafeteria procedures) and on two intervention days. When we increased the portion size of 3 of the 4 fruits and vegetables by about 50%, children who took those foods increased their consumption of them. Although this was an effective strategy for increasing fruit and vegetable consumption among students who took those foods, many children chose not to take any fruits or vegetables. Further efforts are needed to increase children's selection and consumption of fruits and vegetables in an environment of competing foods of higher palatability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. From the point-of-purchase perspective: a qualitative study of the feasibility of interventions aimed at portion-size.

    Science.gov (United States)

    Vermeer, Willemijn M; Steenhuis, Ingrid H M; Seidell, Jacob C

    2009-04-01

    Food portion-sizes might be a promising starting point for interventions targeting obesity. The purpose of this qualitative study was to assess how representatives of point-of-purchase settings perceived the feasibility of interventions aimed at portion-size. Semi-structured interviews were conducted with 22 representatives of various point-of-purchase settings. Constructs derived from the diffusion of innovations theory were incorporated into the interview guide. Each interview was recorded and transcribed verbatim. Data were coded and analysed with Atlas.ti 5.2 using the framework approach. According to the participants, offering a larger variety of portion-sizes had the most relative advantages, and reducing portions was the most disadvantageous. The participants also considered portion-size reduction and linear pricing of portion-sizes to be risky. Lastly, a larger variety of portion-sizes, pricing strategies and portion-size labelling were seen as the most complex interventions. In general, participants considered offering a larger variety of portion-sizes, portion-size labelling and, to a lesser extent, pricing strategies with respect to portion-sizes as most feasible to implement. Interventions aimed at portion-size were seen as innovative by most participants. Developing adequate communication strategies about portion-size interventions with both decision-makers in point-of-purchase settings and the general public is crucial for successful implementation.

  5. A Mixed-Methods Evaluation of the Choose Less, Weigh Less Portion Size Health Marketing Campaign in Los Angeles County.

    Science.gov (United States)

    Gase, Lauren N; Barragan, Noel C; Robles, Brenda; Leighs, Michael; Kuo, Tony

    2015-01-01

    To assess the impact of the Choose Less, Weigh Less portion size health marketing campaign. A mixed-methods, cross-sectional evaluation. A quantitative Internet panel survey was administered through an online sampling vendor and qualitative interviews were conducted by street intercept. The panel survey included 796 participants, weighted to represent Los Angeles County. Street intercept interviews were conducted with 50 other participants. The Choose Less, Weigh Less campaign included print media on transit shelters, bus and rail cars, and billboards; radio and online advertising; and Web site content and social media outreach. The panel survey measured self-reported campaign exposure and outcomes, including knowledge of recommended daily calorie limits, attitudes toward portion sizes, and intent to reduce calories and portion size. Intercept interviews assessed campaign appeal, clarity, and utility. Weighted survey data were analyzed using logistic regression to assess the association between campaign exposure and outcomes. Interview data were analyzed for themes. The campaign reached 19.7% of the Los Angeles County population. Significant differences were seen for 2 of the 10 outcomes assessed. Participants who saw the campaign were more likely than those who did not to report fast-food portion sizes as being too large (adjusted odds ratio [Adj. OR]: 1.89; 95% confidence interval [CI]: 1.16, 3.07) and intention to choose a smaller portion (Adj. OR: 1.99; 95% CI: 1.20, 3.31). Qualitative data revealed three themes about appeal, clarity, and utility. Health marketing efforts targeting portion size can have relatively broad reach and limited but positive impacts on consumer attitudes and intent to select smaller portions.

  6. The effect of food portion sizes on the obesity prevention using system dynamics modelling

    Science.gov (United States)

    Abidin, Norhaslinda Zainal; Zulkepli, Jafri Hj; Zaibidi, Nerda Zura

    2014-09-01

    The rise in income and population growth have increased the demand for food and induced changes in food habits, food purchasing and consumption patterns in Malaysia. With this transition, one of the plausible causes of weight gain and obesity is the frequent consumption of outside food which is synonymous with bigger portion size. Therefore, the aim of this paper is to develop a system dynamics model to analyse the effect of reducing food portion size on weight and obesity prevention. This study combines the different strands of knowledge comprise of nutrition, physical activity and body metabolism. These elements are synthesized into a system dynamics model called SIMULObese. Findings from this study suggested that changes in eating behavior should not emphasize only on limiting the food portion size consumption. The efforts should also consider other eating events such as controlling the meal frequency and limiting intake of high-calorie food in developing guidelines to prevent obesity.

  7. Encouraging vegetable intake as a snack among children: the influence of portion and unit size.

    Science.gov (United States)

    van Kleef, Ellen; Bruggers, Ilse; de Vet, Emely

    2015-10-01

    People eat more unhealthy foods when served more (portion size effect) and when the food is served in larger units (unit size effect). The present study aimed to examine whether these effects can be used for the good: to increase vegetable consumption among children. A 2×2 between-subjects experiment was conducted at two schools. Pupils were presented in class with cucumber that varied both in unit size (one piece v. pre-sliced) and portion size (one-third v. two-thirds of a cucumber). Children ate ad libitum during the morning break and filled in a survey. Primary schools in the centre of the Netherlands. Primary-school pupils (n 255) aged 8-13 years. Children ate 54 % more cucumber when served a large compared with a smaller portion (difference of 49 g; P<0·001). Large units did not impact consumption (P=0·58), but were considered as less convenient to eat than small units (P=0·001). Findings suggest that children's vegetable intake can be improved by serving larger portions in smaller-sized pieces.

  8. The Influence of Portion Size and Timing of Meals on Weight Balance and Obesity.

    Science.gov (United States)

    Berg, Christina; Forslund, Heléne Bertéus

    2015-03-01

    This review focuses on the influence of portion size and temporal distribution of food intake on weight balance and obesity in adults. The inconsistency of definitions in the area of meal patterns is also discussed. The conclusion is that regular eating habits might facilitate weight balance, while unplanned snacking as well as consuming the major part of the energy intake at the end of the day seem to be unfavourable. Altogether, the research suggests that large portions promote over-consumption and, therefore, limiting portion size of energy dense foods and drinks with added sugar could be recommended. Even if more research is needed, these factors should be taken into consideration in recommendations for obesity prevention.

  9. Is there an association between food portion size and BMI among British adolescents?

    Science.gov (United States)

    Albar, Salwa A; Alwan, Nisreen A; Evans, Charlotte E L; Cade, Janet E

    2014-09-14

    The prevalence of obesity has increased simultaneously with the increase in the consumption of large food portion sizes (FPS). Studies investigating this association among adolescents are limited; fewer have addressed energy-dense foods as a potential risk factor. In the present study, the association between the portion size of the most energy-dense foods and BMI was investigated. A representative sample of 636 British adolescents (11-18 years) was used from the 2008-2011 UK National Diet and Nutrition Survey. FPS were estimated for the most energy-dense foods (those containing above 10·5 kJ/g (2·5 kcal/g)). Regression models with BMI as the outcome variable were adjusted for age, sex and misreporting energy intake (EI). A positive association was observed between total EI and BMI. For each 418 kJ (100 kcal) increase in EI, BMI increased by 0·19 kg/m2 (95 % CI 0·10, 0·28; Pportion sizes of a limited number of high-energy-dense foods (high-fibre breakfast cereals, cream and high-energy soft drinks (carbonated)) were found to be positively associated with a higher BMI among all adolescents after adjusting for misreporting. When eliminating the effect of under-reporting, larger portion sizes of a number of high-energy-dense foods (biscuits, cheese, cream and cakes) were found to be positively associated with BMI among normal reporters. The portion sizes of only high-fibre breakfast cereals and high-energy soft drinks (carbonated) were found to be positively associated with BMI among under-reporters. These findings emphasise the importance of considering under-reporting when analysing adolescents' dietary intake data. Also, there is a need to address adolescents' awareness of portion sizes of energy-dense foods to improve their food choice and future health outcomes.

  10. Caregivers' attitudes regarding portion sizes served to children at Head Start

    Science.gov (United States)

    Head Start caregivers are responsible for educating and feeding preschoolers enrolled in the Head Start program. Amongst pre-school aged children, portion size served is positively associated with intake of those foods. Researchers conducted eight focus groups with Hispanic and African American Head...

  11. Improving Accuracy of Portion-Size Estimations through a Stimulus Equivalence Paradigm

    Science.gov (United States)

    Hausman, Nicole L.; Borrero, John C.; Fisher, Alyssa; Kahng, SungWoo

    2014-01-01

    The prevalence of obesity continues to increase in the United States (Gordon-Larsen, The, & Adair, 2010). Obesity can be attributed, in part, to overconsumption of energy-dense foods. Given that overeating plays a role in the development of obesity, interventions that teach individuals to identify and consume appropriate portion sizes are…

  12. A brief mindfulness intervention reduces unhealthy eating when hungry, but not the portion size effect

    NARCIS (Netherlands)

    Marchiori, D.R.; Papies, E.K.

    2014-01-01

    Objective: The present research examined the effects of a mindfulness-based intervention to foster healthy eating. Specifically, we tested whether a brief mindfulness manipulation can prevent the portion size effect, and reduce overeating on unhealthy snacks when hungry. Methods: 110 undergraduate

  13. Swallowing thresholds of mandibular implant-retained overdentures with variable portion sizes

    NARCIS (Netherlands)

    Fontijn-Tekamp, F.A.; Slagter, A.P.; Van der Bilt, A.; Van't Hof, M.A.; Kalk, W.; Jansen, J.A.

    2004-01-01

    We analysed the effect of three portion sizes Optocal Plus (small, medium and large) on swallowing thresholds in subjects with either conventional complete dentures or mandibular implant-retained overdentures (transmandibular and permucosal cylindric implants). Tests were carried out in 52 women and

  14. Reliability and validity of food portion size estimation from images using manual flexible digital virtual meshes

    Science.gov (United States)

    The eButton takes frontal images at 4 second intervals throughout the day. A three-dimensional (3D) manually administered wire mesh procedure has been developed to quantify portion sizes from the two-dimensional (2D) images. This paper reports a test of the interrater reliability and validity of use...

  15. Visual illusions and plate design: the effects of plate rim widths and rim coloring on perceived food portion size.

    Science.gov (United States)

    McClain, A D; van den Bos, W; Matheson, D; Desai, M; McClure, S M; Robinson, T N

    2014-05-01

    The Delboeuf Illusion affects perceptions of the relative sizes of concentric shapes. This study was designed to extend research on the application of the Delboeuf illusion to food on a plate by testing whether a plate's rim width and coloring influence perceptual bias to affect perceived food portion size. Within-subjects experimental design. Experiment 1 tested the effect of rim width on perceived food portion size. Experiment 2 tested the effect of rim coloring on perceived food portion size. In both experiments, participants observed a series of photographic images of paired, side-by-side plates varying in designs and amounts of food. From each pair, participants were asked to select the plate that contained more food. Multilevel logistic regression examined the effects of rim width and coloring on perceived food portion size. Experiment 1: participants overestimated the diameter of food portions by 5% and the visual area of food portions by 10% on plates with wider rims compared with plates with very thin rims (Pfood portion sizes. Experiment 2: participants overestimated the diameter of food portions by 1.5% and the visual area of food portions by 3% on plates with rim coloring compared with plates with no coloring (P=0.01). The effect of rim coloring was greater with smaller food portion sizes. The Delboeuf illusion applies to food on a plate. Participants overestimated food portion size on plates with wider and colored rims. These findings may help design plates to influence perceptions of food portion sizes.

  16. Smaller food item sizes of snack foods influence reduced portions and caloric intake in young adults.

    Science.gov (United States)

    Marchiori, David; Waroquier, Laurent; Klein, Olivier

    2011-05-01

    Studies considering the impact of food-size variations on consumption have predominantly focused on portion size, whereas very little research has investigated variations in food-item size, especially at snacking occasions, and results have been contradictory. This study evaluated the effect of altering the size of food items (ie, small vs large candies) of equal-size food portions on short-term energy intake while snacking. The study used a between-subjects design (n=33) in a randomized experiment conducted in spring 2008. In a psychology laboratory (separate cubicles), participants (undergraduate psychology students, 29 of 33 female, mean age 20.3±2 years, mean body mass index 21.7±3.7) were offered unlimited consumption of candies while participating in an unrelated computerized experiment. For half of the subjects, items were cut in two to make the small food-item size. Food intake (weight in grams, kilocalories, and number of food items) was examined using analysis of variance. Results showed that decreasing the item size of candies led participants to decrease by half their gram weight intake, resulting in an energy intake decrease of 60 kcal compared to the other group. Appetite ratings and subject and food characteristics had no moderating effect. A cognitive bias could explain why people tend to consider that one unit of food (eg, 10 candies) is the appropriate amount to consume, regardless of the size of the food items in the unit. This study suggests a simple dietary strategy, decreasing food-item size without having to alter the portion size offered, may reduce energy intake at snacking occasions. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  17. A brief mindfulness intervention reduces unhealthy eating when hungry, but not the portion size effect.

    Science.gov (United States)

    Marchiori, David; Papies, Esther K

    2014-04-01

    The present research examined the effects of a mindfulness-based intervention to foster healthy eating. Specifically, we tested whether a brief mindfulness manipulation can prevent the portion size effect, and reduce overeating on unhealthy snacks when hungry. 110 undergraduate participants (MAge=20.9±2.3; MBMI=22.3±2.5) were served a small or a large portion of chocolate chip cookies after listening to an audio book or performing a mindfulness exercise (i.e., body scan). Current level of hunger was assessed unobtrusively on a visual analog scale before the eating situation. Calorie intake from chocolate chip cookies. When presented with a large compared to a small portion, participants consumed more cookies (+83kcal). This was not affected by the mindfulness intervention or by hunger. However, while control participants ate more unhealthy food when hungry than when not hungry (+67kcal), participants in the mindfulness condition did not (+1kcal). Findings confirm the prevalence and robustness of the portion size effect and suggest that it may be independent from awareness of internal cues. Prevention strategies may benefit more from targeting awareness of the external environment. However, mindfulness-based interventions may be effective to reduce effects of hunger on unhealthy food consumption. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Unit bias. A new heuristic that helps explain the effect of portion size on food intake.

    Science.gov (United States)

    Geier, Andrew B; Rozin, Paul; Doros, Gheorghe

    2006-06-01

    People seem to think that a unit of some entity (with certain constraints) is the appropriate and optimal amount. We refer to this heuristic as unit bias. We illustrate unit bias by demonstrating large effects of unit segmentation, a form of portion control, on food intake. Thus, people choose, and presumably eat, much greater weights of Tootsie Rolls and pretzels when offered a large as opposed to a small unit size (and given the option of taking as many units as they choose at no monetary cost). Additionally, they consume substantially more M&M's when the candies are offered with a large as opposed to a small spoon (again with no limits as to the number of spoonfuls to be taken). We propose that unit bias explains why small portion sizes are effective in controlling consumption; in some cases, people served small portions would simply eat additional portions if it were not for unit bias. We argue that unit bias is a general feature in human choice and discuss possible origins of this bias, including consumption norms.

  19. LDA measurement of droplet behavior across tie plate during dispersed flow portion of loca reflood

    International Nuclear Information System (INIS)

    Lee, S.L.; Srinivasan, J.; Cho, S.K.

    1980-01-01

    The flow of an air-water droplet dispersion in a simulated 3-D test section in the reflood portion of LOCA was studied. For this purpose, a new scheme of Laser-Doppler Anemometry for the simultaneous measurement of size and velocity of large-size [0.5 mm-6 mm] droplets was developed and utilized. It was observed that the size distribution of the reentrained droplets depends mainly on the flow regimes and is essentially independent of that of the incoming dispersion below the tie plate. 8 refs

  20. Comparison of the portion size and frequency of consumption of 156 foods across seven European countries: insights from the Food4ME study.

    Science.gov (United States)

    Kirwan, L; Walsh, M C; Brennan, L; Gibney, E R; Drevon, C A; Daniel, H; Lovegrove, J A; Manios, Y; Martínez, J A; Saris, W H M; Traczyk, I; Mathers, J C; Gibney, M

    2016-05-01

    There are no standardised serving/portion sizes defined for foods consumed in the European Union (EU). Typical serving sizes can deviate significantly from the 100 g/100 ml labelling specification required by the EU legislation. Where the nutritional value of a portion is specified, the portion size is determined by the manufacturers. Our objective was to investigate the potential for standardising portion sizes for specific foods, thereby ensuring complementarity across countries. We compared portion size for 156 food items measured using a food frequency questionnaire across the seven countries participating in the Food4me study. The probability of consuming a food and the frequency of consumption differed across countries for 93% and 58% of the foods, respectively. However, the individual country mean portion size differed from the average across countries in only 16% of comparisons. Thus, although dietary choices vary markedly across countries, there is much less variation in portion sizes. Our results highlight the potential for standardisation of portion sizes on nutrition labels in the EU.

  1. Secular trends in reported portion size of food and beverages consumed by Irish adults.

    Science.gov (United States)

    O'Brien, Sinead A; Livingstone, M Barbara E; McNulty, Breige A; Lyons, Jacqueline; Walton, Janette; Flynn, Albert; Segurado, Ricardo; Dean, Moira; Spence, Michelle; McCaffrey, Tracy A; Pourshahidi, L Kirsty; Nugent, Anne P; Gibney, Eileen R

    2015-04-14

    The present analysis aimed to investigate the changes in the reported portion sizes (PS) of foods and beverages commonly consumed by Irish adults (18-64 years) from the North South Ireland Food Consumption Survey (NSIFCS) (1997-2001) and the National Adult Nutrition Survey (NANS) (2008-10). Food PS, which are defined as the weight of food (g) consumed per eating occasion, were calculated for comparable foods and beverages in two nationally representative cross-sectional Irish food consumption surveys and were published in NSIFCS and NANS. Repeated measure mixed model analysis compared reported food PS at the total population level as well as subdivided by sex, age, BMI and social class. A total of thirteen commonly consumed foods were examined. The analysis demonstrated that PS significantly increased for five foods ('white sliced bread', 'brown/wholemeal breads', 'all meat, cooked', 'poultry, roasted' and 'milk'), significantly decreased for three ('potatoes', 'chips/wedges' and 'ham, sliced') and did not significantly change for five foods ('processed potato products', 'bacon/ham', 'cheese', 'yogurt' and 'butter/spreads') between the NSIFCS and the NANS. The present study demonstrates that there was considerable variation in the trends in reported food PS over this period.

  2. Assessing food appeal and desire to eat: the effects of portion size & energy density

    OpenAIRE

    Cornier Marc A; Burger Kyle S; Ingebrigtsen Jan; Johnson Susan L

    2011-01-01

    Abstract Background Visual presentation of food provides considerable information such as its potential for palatability and availability, both of which can impact eating behavior. Methods We investigated the subjective ratings for food appeal and desire to eat when exposed to food pictures in a fed sample (n = 129) using the computer paradigm ImageRate. Food appeal and desire to eat were analyzed for the effects of food group, portion size and energy density of the foods presented as well as...

  3. Assessing food appeal and desire to eat: The effects of portion size & energy density

    OpenAIRE

    Burger, Kyle

    2017-01-01

    Background: Visual presentation of food provides considerable information such as its potential for palatability and availability, both of which can impact eating behavior. Methods: We investigated the subjective ratings for food appeal and desire to eat when exposed to food pictures in a fed sample (n=129) using the computer paradigm ImageRate. Food appeal and desire to eat were analyzed for the effects of food group, portion size and energy density of the foods presented as well as by parti...

  4. Portion size me : Plate-size induced consumption norms and education futility

    NARCIS (Netherlands)

    Wansink, B.; van Ittersum, Koert

    2013-01-01

    Research on the self-serving of food has empirically ignored the role that visual consumption norms play in determining how much food we serve on different sized dinnerware. We contend that dinnerware provides a visual anchor of an appropriate fill-level, which in turn, serves as a consumption norm

  5. Value for money or making the healthy choice: the impact of proportional pricing on consumers' portion size choices

    NARCIS (Netherlands)

    Vermeer, W.M.; Alting, E.; Steenhuis, I.H.M.; Seidell, J.C.

    2010-01-01

    Background: Large food portion sizes are determinants of a high caloric intake, especially if they have been made attractive through value size pricing (i.e. lower unit prices for large than for small portion sizes). The purpose of the two questionnaire studies that are reported in this article was

  6. Food and beverage portion sizes in Australian children: a secondary analysis of 1995 and 2007 national data

    OpenAIRE

    Collins, Kate; Watson, Jane F; Collins, Clare E

    2014-01-01

    Background Portion size of foods is reported to contribute to the rise in obesity prevalence. However, evidence of changes in portion size for commonly consumed foods in Australia is lacking. The aim was to evaluate whether Australian child and adolescent portion sizes of selected foods changed from 1995 to 2007. Methods Time-series study, comparing dietary data from two national cross-sectional surveys in nationally representative population survey of Australian households. The dietary data ...

  7. Food photography II: use of food photographs for estimating portion size and the nutrient content of meals.

    Science.gov (United States)

    Nelson, M; Atkinson, M; Darbyshire, S

    1996-07-01

    The aim of the present study was to determine the errors in the conceptualization of portion size using photographs. Male and female volunteers aged 18-90 years (n 136) from a wide variety of social and occupational backgrounds completed 602 assessments of portion size in relation to food photographs. Subjects served themselves between four and six foods at one meal (breakfast, lunch or dinner). Portion sizes were weighed by the investigators at the time of serving, and any waste was weighed at the end of the meal. Within 5 min of the end of the meal, subjects were shown photographs depicting each of the foods just consumed. For each food there were eight photographs showing portion sizes in equal increments from the 5th to the 95th centile of the distribution of portion weights observed in The Dietary and Nutritional Survey of British Adults (Gregory et al. 1990). Subjects were asked to indicate on a visual analogue scale the size of the portion consumed in relation to the eight photographs. The nutrient contents of meals were estimated from food composition tables. There were large variations in the estimation of portion sizes from photographs. Butter and margarine portion sizes tended to be substantially overestimated. In general, small portion sizes tended to be overestimated, and large portion sizes underestimated. Older subjects overestimated portion size more often than younger subjects. Excluding butter and margarine, the nutrient content of meals based on estimated portion sizes was on average within +/- 7% of the nutrient content based on the amounts consumed, except for vitamin C (21% overestimate), and for subjects over 65 years (15-20% overestimate for energy and fat). In subjects whose BMI was less than 25 kg/m2, the energy and fat contents of meals calculated from food composition tables and based on estimated portion size (excluding butter and margarine) were 5-10% greater than the nutrient content calculated using actual portion size, but for those

  8. Evaluation of a photographic food atlas as a tool for quantifying food portion size in the United Arab Emirates

    Science.gov (United States)

    Platat, Carine; El Mesmoudi, Najoua; El Sadig, Mohamed; Tewfik, Ihab

    2018-01-01

    Although, United Arab Emirates (UAE) has one of the highest prevalence of overweight, obesity and type 2 diabetes in the world, however, validated dietary assessment aids to estimate food intake of individuals and populations in the UAE are currently lacking. We conducted two observational studies to evaluate the accuracy of a photographic food atlas which was developed as a tool for food portion size estimation in the UAE. The UAE Food Atlas presents eight portion sizes for each food. Study 1 involved portion size estimations of 13 food items consumed during the previous day. Study 2 involved portion size estimations of nine food items immediately after consumption. Differences between the food portion sizes estimated from the photographs and the weighed food portions (estimation error), as well as the percentage differences relative to the weighed food portion for each tested food item were calculated. Four of the evaluated food items were underestimated (by -8.9% to -18.4%), while nine were overestimated (by 9.5% to 90.9%) in Study 1. Moreover, there were significant differences between estimated and eaten food portions for eight food items (Pfood item was underestimated (-8.1%) while eight were overestimated (range 2.52% to 82.1%). Furthermore, there were significant differences between estimated and eaten food portions (Pfood items. The limits of agreement between the estimated and consumed food portion size were wide indicating a large variability in food portion estimation errors. These reported findings highlight the need for further developments of the UAE Food Atlas to improve the accuracy of food portion size intake estimations in dietary assessments. Additionally, recalling food portions from the previous day did not seem to increase food portion estimation errors in this study. PMID:29698434

  9. Children's accuracy of portion size estimation using digital food images: effects of interface design and size of image on computer screen.

    Science.gov (United States)

    Baranowski, Tom; Baranowski, Janice C; Watson, Kathleen B; Martin, Shelby; Beltran, Alicia; Islam, Noemi; Dadabhoy, Hafza; Adame, Su-heyla; Cullen, Karen; Thompson, Debbe; Buday, Richard; Subar, Amy

    2011-03-01

    To test the effect of image size and presence of size cues on the accuracy of portion size estimation by children. Children were randomly assigned to seeing images with or without food size cues (utensils and checked tablecloth) and were presented with sixteen food models (foods commonly eaten by children) in varying portion sizes, one at a time. They estimated each food model's portion size by selecting a digital food image. The same food images were presented in two ways: (i) as small, graduated portion size images all on one screen or (ii) by scrolling across large, graduated portion size images, one per sequential screen. Laboratory-based with computer and food models. Volunteer multi-ethnic sample of 120 children, equally distributed by gender and ages (8 to 13 years) in 2008-2009. Average percentage of correctly classified foods was 60·3 %. There were no differences in accuracy by any design factor or demographic characteristic. Multiple small pictures on the screen at once took half the time to estimate portion size compared with scrolling through large pictures. Larger pictures had more overestimation of size. Multiple images of successively larger portion sizes of a food on one computer screen facilitated quicker portion size responses with no decrease in accuracy. This is the method of choice for portion size estimation on a computer.

  10. Food and beverage portion sizes in Australian children: a secondary analysis of 1995 and 2007 national data.

    Science.gov (United States)

    Collins, Kate; Watson, Jane F; Collins, Clare E

    2014-05-28

    Portion size of foods is reported to contribute to the rise in obesity prevalence. However, evidence of changes in portion size for commonly consumed foods in Australia is lacking. The aim was to evaluate whether Australian child and adolescent portion sizes of selected foods changed from 1995 to 2007. Time-series study, comparing dietary data from two national cross-sectional surveys in nationally representative population survey of Australian households. The dietary data was from children aged 2-16 years who participated in the 1995 National Nutrition Survey (n = 2198) and 2007 Australian National Children's Nutrition and Physical Activity Survey (n = 4799). Differences were found across survey years in median portion size of common foods and beverages assessed by 24-hour recalls for age and sex categories. Of the 61 foods items evaluated across the whole population sample, portion size increased in 18 items, decreased in 22, with no change in 20, although the magnitude of change varied by age and sex. Decreases in portion size were detected for most dairy products, breakfast cereal, some packaged snack foods and vegetables, p portion sizes were detected over 12 years in Australian children and adolescents with the degree of change varying by sex, age and food group. Knowledge of usual portion sizes could inform programs targeting appropriate serving sizes selection in children and adolescents.

  11. Impact of fruit juice and beverage portion size on snack intake in preschoolers.

    Science.gov (United States)

    Norton, Erin M; Poole, Seletha A; Raynor, Hollie A

    2015-12-01

    It has been recommended that beverages other than 100% fruit juice, such as water, be served at meals and snacks for preschool-aged children to reduce excessive energy intake. Using a 2 × 2 × 2 design (between-subjects factor of order and within-subjects factors of beverage type and size), 26 children (3.9 ± 0.6 years of age, 50% female, 73% white, and 88.5% non-Hispanic or Latino) completed four, 20-min snack sessions consisting of 200 g of applesauce, 60 g of graham crackers, and either 6 oz. (approximately 180 g) or 12 oz. (approximately 360 g) of 100% berry fruit juice or water, to examine the influence of 100% fruit juice and the portion size of the provided fruit juice, on beverage, food, and overall snack intake. Mixed-factor analyses of covariance revealed a significant (p snack energy intake, with more overall energy consumed when juice was provided (175.4 ± 50.0 kcal vs. 104.8 ± 62.8 kcal, p snack increased beverage and/or food intake, and serving 100% juice led to greater overall snack energy intake. Future research should examine the role of 100% fruit juice, and beverage portion size, in contributing to excessive daily energy intake in preschool-aged children. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Assessing food appeal and desire to eat: the effects of portion size & energy density.

    Science.gov (United States)

    Burger, Kyle S; Cornier, Marc A; Ingebrigtsen, Jan; Johnson, Susan L

    2011-09-25

    Visual presentation of food provides considerable information such as its potential for palatability and availability, both of which can impact eating behavior. We investigated the subjective ratings for food appeal and desire to eat when exposed to food pictures in a fed sample (n=129) using the computer paradigm ImageRate. Food appeal and desire to eat were analyzed for the effects of food group, portion size and energy density of the foods presented as well as by participant characteristics. Food appeal ratings were significantly higher than those for desire to eat (57.9±11.6 v. 44.7±18.0; pappeal. Food category analyses revealed that fruit was the highest rated food category for both appeal and desire, followed by discretionary foods. Additionally, overweight individuals reported higher ratings of desire to eat large portions of food compared to smaller portions (pappeal and desire (r's=-0.27; p'sappeal and desire to eat foods when assessing these ratings using the same type of metric. Additionally, relations among food appeal and desire to eat ratings and body mass show overweight individuals could be more responsive to visual foods cues in a manner that contributes to obesity.

  13. Menu-engineering in restaurants - adapting portion sizes on plates to enhance vegetable consumption: a real-life experiment.

    NARCIS (Netherlands)

    Reinders, M.J.; Huitink, M.; Dijkstra, S.C.; Maaskant, A.J.; Heijnen, J.

    2017-01-01

    Background: The aim of this research was to investigate whether increased portion sizes of vegetables and decreased portion sizes of meat on main dishes increased the amount of vegetables consumed in a real-life restaurant setting without affecting customer satisfaction. The participants were

  14. From the point-of-purchase perspective: a qualitative study of the feasibility of interventions aimed at portion-size

    NARCIS (Netherlands)

    Vermeer, W.M.; Steenhuis, I.H.M.; Seidell, J.C.

    2009-01-01

    Objectives: Food portion-sizes might be a promising starting point for interventions targeting obesity. The purpose of this qualitative study was to assess how representatives of point-of-purchase settings perceived the feasibility of interventions aimed at portion-size. Methods: Semi-structured

  15. Texture-Based Differences in Eating Rate Reduce the Impact of Increased Energy Density and Large Portions on Meal Size in Adults.

    Science.gov (United States)

    McCrickerd, Keri; Lim, Charlotte Mh; Leong, Claudia; Chia, Edwin M; Forde, Ciaran G

    2017-06-01

    Background: Large portions and high dietary energy density promote overconsumption at meal times. This could be reduced by eating slowly. Objective: Two studies investigated whether texture-based reductions in eating rate and oral processing moderate consumption at breakfast in combination with variations in energy density and portion size. Methods: Adults attended 4 breakfast sessions (2 × 2 repeated-measures design) to consume rice porridge, combining a 45% reduction in eating rate [thin porridge (140 g/min) compared with thick porridge (77 g/min)] with a 77% increase in energy density (0.57 compared with 1.01 kcal/g) in study 1 [ n = 61; aged 21-48 y; body mass index (BMI; in kg/m 2 ): 16-29] and a 50% increase in portion size (100% compared with 150%) in study 2 ( n = 53; aged 21-42 y; BMI: 16-29). Oral processing behaviors were coded by using webcams. Porridge intake was measured alongside changes in rated appetite. Results: Increases in energy density and portion size led to increases of 80% and 13% in energy intake at breakfast, respectively ( P portion size increased the weight of food consumed (13%). The thicker porridges were consumed at a slower rate and led to 11-13% reductions in food weight and energy intake compared with the thin versions ( P portion ( P portions, and natural variations in food texture to design meals that promote reductions in energy intake while maintaining satiety. © 2017 American Society for Nutrition.

  16. Restaurant owners' perspectives on a voluntary program to recognize restaurants for offering reduced-size portions, Los Angeles County, 2012.

    Science.gov (United States)

    Gase, Lauren; Dunning, Lauren; Kuo, Tony; Simon, Paul; Fielding, Jonathan E

    2014-03-20

    Reducing the portion size of food and beverages served at restaurants has emerged as a strategy for addressing the obesity epidemic; however, barriers and facilitators to achieving this goal are not well characterized. In fall 2012, the Los Angeles County Department of Public Health conducted semistructured interviews with restaurant owners to better understand contextual factors that may impede or facilitate participation in a voluntary program to recognize restaurants for offering reduced-size portions. Interviews were completed with 18 restaurant owners (representing nearly 350 restaurants). Analyses of qualitative data revealed 6 themes related to portion size: 1) perceived customer demand is central to menu planning; 2) multiple portion sizes are already being offered for at least some food items; 3) numerous logistical barriers exist for offering reduced-size portions; 4) restaurant owners have concerns about potential revenue losses from offering reduced-size portions; 5) healthful eating is the responsibility of the customer; and 6) a few owners want to be socially responsible industry leaders. A program to recognize restaurants for offering reduced-size portions may be a feasible approach in Los Angeles County. These findings may have applications for jurisdictions interested in engaging restaurants as partners in reducing the obesity epidemic.

  17. Restaurant Owners’ Perspectives on a Voluntary Program to Recognize Restaurants for Offering Reduced-Size Portions, Los Angeles County, 2012

    Science.gov (United States)

    Dunning, Lauren; Kuo, Tony; Simon, Paul; Fielding, Jonathan E.

    2014-01-01

    Introduction Reducing the portion size of food and beverages served at restaurants has emerged as a strategy for addressing the obesity epidemic; however, barriers and facilitators to achieving this goal are not well characterized. Methods In fall 2012, the Los Angeles County Department of Public Health conducted semistructured interviews with restaurant owners to better understand contextual factors that may impede or facilitate participation in a voluntary program to recognize restaurants for offering reduced-size portions. Results Interviews were completed with 18 restaurant owners (representing nearly 350 restaurants). Analyses of qualitative data revealed 6 themes related to portion size: 1) perceived customer demand is central to menu planning; 2) multiple portion sizes are already being offered for at least some food items; 3) numerous logistical barriers exist for offering reduced-size portions; 4) restaurant owners have concerns about potential revenue losses from offering reduced-size portions; 5) healthful eating is the responsibility of the customer; and 6) a few owners want to be socially responsible industry leaders. Conclusion A program to recognize restaurants for offering reduced-size portions may be a feasible approach in Los Angeles County. These findings may have applications for jurisdictions interested in engaging restaurants as partners in reducing the obesity epidemic. PMID:24650622

  18. Half-size me? How calorie and price information influence ordering on restaurant menus with both half and full entrée portion sizes.

    Science.gov (United States)

    Haws, Kelly L; Liu, Peggy J

    2016-02-01

    Many restaurants are increasingly required to display calorie information on their menus. We present a study examining how consumers' food choices are affected by the presence of calorie information on restaurant menus. However, unlike prior research on this topic, we focus on the effect of calorie information on food choices made from a menu that contains both full size portions and half size portions of entrées. This different focus is important because many restaurants increasingly provide more than one portion size option per entrée. Additionally, we examine whether the impact of calorie information differs depending on whether full portions are cheaper per unit than half portions (non-linear pricing) or whether they have a similar per unit price (linear pricing). We find that when linear pricing is used, calorie information leads people to order fewer calories. This decrease occurs as people switch from unhealthy full sized portions to healthy full sized portions, not to unhealthy half sized portions. In contrast, when non-linear pricing is used, calorie information has no impact on calories selected. Considering the impact of calorie information on consumers' choices from menus with more than one entrée portion size option is increasingly important given restaurant and legislative trends, and the present research demonstrates that calorie information and pricing scheme may interact to affect choices from such menus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Changes in Typical Portion Sizes of Commonly Consumed Discretionary Foods among Australian Adults from 1995 to 2011–2012

    Science.gov (United States)

    Zheng, Miaobing; Rangan, Anna; Meertens, Beth; Wu, Jason H. Y.

    2017-01-01

    This study aimed to examine the changes in typical portion sizes of commonly consumed discretionary foods among Australian adults from 1995 to 2011–2012. Data of adults (age ≥19 years) from the 1995 Australian National Nutrition Survey and 2011–2012 National Nutrition and Physical Activity Survey were used. Typical portion sizes (median portion) of fourteen discretionary foods that contributed the most to energy intake were determined. Ten out of fourteen food categories demonstrated a significant change in kJ per typical portion from 1995 to 2011–2012 (p ≤ 0.001). kJ per typical portion increased for pizza, cake, sausage, cereal bar, processed meat, ice cream and wine, with pizza and cake demonstrating the largest increases (+570 kJ and +950 kJ in 2011–2012, respectively; both +66% above 1995). In contrast, kJ per typical portion of pastry, snack food and potato fries decreased by 10–40% over time, and did not change for biscuit, chocolate, sugar-sweetened beverage and beer. Similar changes were observed for grams per typical portion consumed. Temporal trends in typical portion sizes were similar according to age group, gender and socioeconomic status. The findings suggest that population-wide strategies that enable consumers to choose smaller portions of discretionary foods are needed to reduce the excess consumption of these products. PMID:28587276

  20. Changes in Typical Portion Sizes of Commonly Consumed Discretionary Foods among Australian Adults from 1995 to 2011–2012

    Directory of Open Access Journals (Sweden)

    Miaobing Zheng

    2017-06-01

    Full Text Available This study aimed to examine the changes in typical portion sizes of commonly consumed discretionary foods among Australian adults from 1995 to 2011–2012. Data of adults (age ≥19 years from the 1995 Australian National Nutrition Survey and 2011–2012 National Nutrition and Physical Activity Survey were used. Typical portion sizes (median portion of fourteen discretionary foods that contributed the most to energy intake were determined. Ten out of fourteen food categories demonstrated a significant change in kJ per typical portion from 1995 to 2011–2012 (p ≤ 0.001. kJ per typical portion increased for pizza, cake, sausage, cereal bar, processed meat, ice cream and wine, with pizza and cake demonstrating the largest increases (+570 kJ and +950 kJ in 2011–2012, respectively; both +66% above 1995. In contrast, kJ per typical portion of pastry, snack food and potato fries decreased by 10–40% over time, and did not change for biscuit, chocolate, sugar-sweetened beverage and beer. Similar changes were observed for grams per typical portion consumed. Temporal trends in typical portion sizes were similar according to age group, gender and socioeconomic status. The findings suggest that population-wide strategies that enable consumers to choose smaller portions of discretionary foods are needed to reduce the excess consumption of these products.

  1. Using multi-theory model to predict initiation and sustenance of small portion size consumption among college students

    Directory of Open Access Journals (Sweden)

    Manoj Sharma

    2016-08-01

    Conclusion: Based on this study’s findings, MTM appears to be a robust theoretical framework for predicting small portion size consumption behavior change. Interventions in this regard need to be designed.

  2. Effect of reducing portion size at a compulsory meal on later energy intake, gut hormones, and appetite in overweight adults.

    Science.gov (United States)

    Lewis, Hannah B; Ahern, Amy L; Solis-Trapala, Ivonne; Walker, Celia G; Reimann, Frank; Gribble, Fiona M; Jebb, Susan A

    2015-07-01

    Larger portion sizes (PS) are associated with greater energy intake (EI), but little evidence exists on the appetitive effects of PS reduction. This study investigated the impact of reducing breakfast PS on subsequent EI, postprandial gastrointestinal hormone responses, and appetite ratings. In a randomized crossover design (n = 33 adults; mean BMI 29 kg/m(2) ), a compulsory breakfast was based on 25% of gender-specific estimated daily energy requirements; PS was reduced by 20% and 40%. EI was measured at an ad libitum lunch (240 min) and snack (360 min) and by weighed diet diaries until bed. Blood was sampled until lunch in 20 participants. Appetite ratings were measured using visual analogue scales. EI at lunch (control: 2,930 ± 203; 20% reduction: 2,853 ± 198; 40% reduction: 2,911 ± 179 kJ) and over the whole day except breakfast (control: 7,374 ± 361; 20% reduction: 7,566 ± 468; 40% reduction: 7,413 ± 417 kJ) did not differ. Postprandial PYY, GLP-1, GIP, insulin, and fullness profiles were lower and hunger, desire to eat, and prospective consumption higher following 40% reduction compared to control. Appetite ratings profiles, but not hormone concentrations, were associated with subsequent EI. Smaller portions at breakfast led to reductions in gastrointestinal hormone secretion but did not affect subsequent energy intake, suggesting small reductions in portion size may be a useful strategy to constrain EI. © 2015 The Obesity Society.

  3. The effect of a portion size intervention on French fries consumption, plate waste, satiety and compensatory caloric intake: an on-campus restaurant experiment.

    Science.gov (United States)

    Vermote, Marie; Versele, Vickà; Stok, Marijn; Mullie, Patrick; D'Hondt, Eva; Deforche, Benedicte; Clarys, Peter; Deliens, Tom

    2018-04-13

    One of the driving factors of dietary overconsumption throughout the last decennia is the increase of food portion sizes. Larger portions induce higher daily energy intake, so reducing portion size may reduce intake of excess calories. However, real-life studies about the effects of portion size reduction are lacking. Therefore, this study examined the effect of a French fries portion size reduction on French fries consumption, French fries plate waste, satiety and caloric intake during the subsequent afternoon among university students and employees in a Belgian on-campus restaurant setting. Moreover, this study evaluated consumers' perception about the portion size reduction. The study took place over a two-time (i.e. baseline and intervention week) 4-day period (Tuesday-Friday) in the on-campus restaurant where ±1200 meals are served every day. French fries' portions were reduced by 20% by replacing the usual porcelain bowl served during the baseline week (±200 g) with smaller volume paper bags during the intervention week (±159 g) in a pre-post real-life experiment. French fries consumption and plate waste were measured in 2056 consumers at baseline and 2175 consumers at intervention. Additionally, interviews were conducted directly after lunch and again between 4 and 6 p.m. on the same day to assess satiety and caloric intake at pre and post in a small subsample of both French fries consumers (n = 19) and non-French fries consumers (n = 14). Post-intervention, the same subsample was interviewed about their perception of the portion size reduction (n = 28). Total French fries intake decreased by 9.1%, and total plate waste decreased by 66.4%. No differences were found in satiety or caloric intake between baseline and intervention week among the French fries' consumers. The majority (n = 24, 86%) of French fries consumers noticed the reduction in portion size during the intervention. Although most participants (n = 19, 68%) perceived the

  4. News Media Framing of New York City’s Sugar-Sweetened Beverage Portion-Size Cap

    Science.gov (United States)

    Cohen, Joanna E.; Truant, Patricia L.; Rutkow, Lainie; Kanarek, Norma F.; Barry, Colleen L.

    2015-01-01

    Objectives. We assessed news media framing of New York City’s proposed regulation to prohibit the sale of sugar-sweetened beverages greater than 16 ounces. Methods. We conducted a quantitative content analysis of print and television news from within and outside New York City media markets. We examined support for and opposition to the portion-size cap in the news coverage from its May 31, 2012, proposal through the appellate court ruling on July 31, 2013. Results. News coverage corresponded to key events in the policy’s evolution. Although most stories mentioned obesity as a problem, a larger proportion used opposing frames (84%) than pro-policy frames (36%). Mention of pro-policy frames shifted toward the policy’s effect on special populations. The debate’s most prominent frame was the opposing frame that the policy was beyond the government’s role (69%). Conclusions. News coverage within and outside the New York City media market was more likely to mention arguments in opposition to than in support of the portion-size cap. Understanding how the news media framed this issue provides important insights for advocates interested in advancing similar measures in other jurisdictions. PMID:26378853

  5. Assessing food appeal and desire to eat: the effects of portion size & energy density

    Directory of Open Access Journals (Sweden)

    Cornier Marc A

    2011-09-01

    Full Text Available Abstract Background Visual presentation of food provides considerable information such as its potential for palatability and availability, both of which can impact eating behavior. Methods We investigated the subjective ratings for food appeal and desire to eat when exposed to food pictures in a fed sample (n = 129 using the computer paradigm ImageRate. Food appeal and desire to eat were analyzed for the effects of food group, portion size and energy density of the foods presented as well as by participant characteristics. Results Food appeal ratings were significantly higher than those for desire to eat (57.9 ± 11.6 v. 44.7 ± 18.0; p r = 0.20; p p r's = - 0.27; p's Conclusions Results support the hypothesis that individuals differentiate between food appeal and desire to eat foods when assessing these ratings using the same type of metric. Additionally, relations among food appeal and desire to eat ratings and body mass show overweight individuals could be more responsive to visual foods cues in a manner that contributes to obesity.

  6. Menu-engineering in restaurants - adapting portion sizes on plates to enhance vegetable consumption: a real-life experiment.

    Science.gov (United States)

    Reinders, Machiel J; Huitink, Marlijn; Dijkstra, S Coosje; Maaskant, Anna J; Heijnen, Joris

    2017-12-25

    The aim of this research was to investigate whether increased portion sizes of vegetables and decreased portion sizes of meat on main dishes increased the amount of vegetables consumed in a real-life restaurant setting without affecting customer satisfaction. The participants were unaware of the experiment. A cross-over design was used in which three restaurants were randomly assigned to a sequence of an intervention and control condition. In the intervention period, the vegetable portion sizes on the plates of main dishes were doubled (150 g of vegetables instead of 75 g) and the portion sizes of meat on the plates were reduced by an average of 12.5%. In the control period, the portion sizes of the main dishes were maintained as usual. In total, 1006 observations and questionnaires were included. Vegetable consumption from plates was significantly higher during the intervention period (M = 115.5 g) than during the control period (M = 61.7 g). Similarly, total vegetable consumption (including side dishes) was significantly higher during the intervention period (M = 178.0 g) than during the control period (M = 137.0 g). Conversely, meat consumption was significantly lower during the intervention period (M = 183.1 g) than during the control period (M = 211.1 g). Satisfaction with the restaurant visit did not differ between the intervention period (M = 1.27) and control period (M = 1.35). Satisfaction with the main dish was significantly lower during the intervention period (M = 1.25) than during the control period (M = 1.38), although in both cases, the scores indicated that participants remained (very) satisfied with their main dish. This study showed that increasing vegetable portions in combination with decreasing meat portions (unknowingly to the consumer) increased the amount of vegetables consumed and decreased the amount of meat consumed. Furthermore, despite the changes in portion sizes, participants remained satisfied

  7. An evaluation of a colour food photography atlas as a tool for quantifying food portion size in epidemiological dietary surveys.

    Science.gov (United States)

    Turconi, G; Guarcello, M; Berzolari, F Gigli; Carolei, A; Bazzano, R; Roggi, C

    2005-08-01

    To test the validity of a colour food photography atlas for quantifying portion size eaten compared with weighed foods. The colour food photography atlas was prepared by cooking, weighing and taking digital photographs of three portion sizes of 434 foods and beverages typical of the Italian diet. In all, 448 male and female volunteers aged 6-60 y from a wide variety of social backgrounds completed 9075 assessments of food portions eaten at lunch and dinner in relation to a set of colour food photographs during 8 weeks of investigation. The amounts of foods eaten by individuals in five different cafeterias in Pavia, Northern Italy, were weighed by trained investigators at the time of serving and, within 5-10 min of the end of the meal, each subject was asked to quantify all foods consumed with reference to one of the three food photographs or in terms of virtual portions among those shown in the photographs. Multiple regression analysis shows that weights of portion sizes chosen from the set of photographs are significantly associated (P<0.05) to weights of eaten portions (beta=0.81; R(2)=0.70) and are independent of age, gender and BMI. The differences between mean weights of the portions chosen by individuals from photographs and mean weights of eaten foods are significant for all food categories (P<0.05), except for bread. However, because of the very large number of observations, the mean differences are very small (range: from +23.2 g (+11.2%) for first courses to -1.3 g (-2.7%) for bread). Bland-Altman plots show that first courses limits of agreement are wide because the dispersion is increasing while weights are rising. The use of a series of three photographs and virtual portion sizes being associated with relatively small errors, our findings support the validity of using this colour food photography atlas as a tool for quantifying food portion size in epidemiological dietary surveys on different age groups of Italian subjects.

  8. Comparing two psychological interventions in reducing impulsive processes of eating behaviour : Effects on self-selected portion size

    NARCIS (Netherlands)

    van Koningsbruggen, G.M.; Veling, H.P.; Stroebe, Wolfgang; Aarts, Henk

    2014-01-01

    ObjectivePalatable food, such as sweets, contains properties that automatically trigger the impulse to consume it even when people have goals or intentions to refrain from consuming such food. We compared the effectiveness of two interventions in reducing the portion size of palatable food that

  9. Meal portion sizes and their potential impacts on food waste: case study of school meals in Italy

    Directory of Open Access Journals (Sweden)

    Marta Castrica

    2018-06-01

    Full Text Available School catering services are characterized by a significant level of inefficiency regarding the food processed but not consumed during meals. This work analyses the meal supply in primary schools in Italy in order to highlight new areas of inefficiency upstream of the food chain. A lack of conformity of food portions with nutritional guidelines can potentially lead to a double negative externality: overweight children and food waste. Data were collected between April and June 2017 from the municipality website of each regional capital (RC of the 20 Italian regions. From the tendering process for primary school meal provision, data on the portions (in grams of the most representative food categories were extracted and classified. To evaluate the degree of homogeneity amongst different regions, the average, minimum and maximum values, standard deviations and relative standard deviations of each individual food category were estimated. To verify the adherence to nutritional recommendations, ANOVA was performed for multiple comparisons combined with Duncan's multiple range test, with significance set at a p value < 0.05. The specific benchmarks for the evaluation of meal portion sizes were calculated based on the National Recommended Energy and Nutrient Intake Levels. The results (table 1 show a great variability of food portions amongst the RCs analyzed. Food categories with highest relative standard deviations values were cooked and raw vegetables (0.29 and 0.35 respectively that indicate great levels of heterogeneity in food portions amongst Italian regions. Conversely, pasta and rice portions were more uniform (0.10 and 0.13, although on average above than the recommended portion. The only food categories characterized by a smaller mean portion than recommended are fish, raw vegetables and cooked vegetables. The educational role of eating at school can contribute to raising children's awareness about one of the most urgent environmental

  10. Assessment of the accuracy of portion size reports using computer-based food photographs aids in the development of an automated self-administered 24-hour recall.

    Science.gov (United States)

    Subar, Amy F; Crafts, Jennifer; Zimmerman, Thea Palmer; Wilson, Michael; Mittl, Beth; Islam, Noemi G; McNutt, Suzanne; Potischman, Nancy; Buday, Richard; Hull, Stephen G; Baranowski, Tom; Guenther, Patricia M; Willis, Gordon; Tapia, Ramsey; Thompson, Frances E

    2010-01-01

    To assess the accuracy of portion-size estimates and participant preferences using various presentations of digital images. Two observational feeding studies were conducted. In both, each participant selected and consumed foods for breakfast and lunch, buffet style, serving themselves portions of nine foods representing five forms (eg, amorphous, pieces). Serving containers were weighed unobtrusively before and after selection as was plate waste. The next day, participants used a computer software program to select photographs representing portion sizes of foods consumed the previous day. Preference information was also collected. In Study 1 (n=29), participants were presented with four different types of images (aerial photographs, angled photographs, images of mounds, and household measures) and two types of screen presentations (simultaneous images vs an empty plate that filled with images of food portions when clicked). In Study 2 (n=20), images were presented in two ways that varied by size (large vs small) and number (4 vs 8). Convenience sample of volunteers of varying background in an office setting. Repeated-measures analysis of variance of absolute differences between actual and reported portions sizes by presentation methods. Accuracy results were largely not statistically significant, indicating that no one image type was most accurate. Accuracy results indicated the use of eight vs four images was more accurate. Strong participant preferences supported presenting simultaneous vs sequential images. These findings support the use of aerial photographs in the automated self-administered 24-hour recall. For some food forms, images of mounds or household measures are as accurate as images of food and, therefore, are a cost-effective alternative to photographs of foods. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  11. Portion, package or tableware size for changing selection and consumption of food, alcohol and tobacco

    OpenAIRE

    Hollands, Gareth J; Shemilt, Ian; Marteau, Theresa M; Jebb, Susan A; Lewis, Hannah B; Wei, Yinghui; Higgins, Julian Pt; Ogilvie, David

    2015-01-01

    Background Overeating and harmful alcohol and tobacco use have been linked to the aetiology of various non-communicable diseases, which are among the leading global causes of morbidity and premature mortality. As people are repeatedly exposed to varying sizes and shapes of food, alcohol and tobacco products in environments such as shops, restaurants, bars and homes, this has stimulated public health policy interest in product size and shape as potential targets for intervention. Objectives 1)...

  12. Effect of reducing portion size at a compulsory meal on later energy intake, gut hormones, and appetite in overweight adults.

    OpenAIRE

    Lewis, HB; Ahern, AL; Solis-Trapala, I; Walker, CG; Reimann, F; Gribble, FM; Jebb, SA

    2015-01-01

    OBJECTIVE: Larger portion sizes (PS) are associated with greater energy intake (EI), but little evidence exists on the appetitive effects of PS reduction. This study investigated the impact of reducing breakfast PS on subsequent EI, postprandial gastrointestinal hormone responses, and appetite ratings. METHODS: In a randomized crossover design (n = 33 adults; mean BMI 29 kg/m(2) ), a compulsory breakfast was based on 25% of gender-specific estimated daily energy requirements; PS was reduced b...

  13. The Impact of Nutrition and Health Claims on Consumer Perceptions and Portion Size Selection: Results from a Nationally Representative Survey

    Science.gov (United States)

    Benson, Tony; Lavelle, Fiona; McCloat, Amanda; Mooney, Elaine; Egan, Bernadette; Collins, Clare E.; Dean, Moira

    2018-01-01

    Nutrition and health claims on foods can help consumers make healthier food choices. However, claims may have a ‘halo’ effect, influencing consumer perceptions of foods and increasing consumption. Evidence for these effects are typically demonstrated in experiments with small samples, limiting generalisability. The current study aimed to overcome this limitation through the use of a nationally representative survey. In a cross-sectional survey of 1039 adults across the island of Ireland, respondents were presented with three different claims (nutrition claim = “Low in fat”; health claim = “With plant sterols. Proven to lower cholesterol”; satiety claim = “Fuller for longer”) on four different foods (cereal, soup, lasagne, and yoghurt). Participants answered questions on perceived healthiness, tastiness, and fillingness of the products with different claims and also selected a portion size they would consume. Claims influenced fillingness perceptions of some of the foods. However, there was little influence of claims on tastiness or healthiness perceptions or the portion size selected. Psychological factors such as consumers’ familiarity with foods carrying claims and belief in the claims were the most consistent predictors of perceptions and portion size selection. Future research should identify additional consumer factors that may moderate the relationships between claims, perceptions, and consumption. PMID:29789472

  14. Calibration of the food list and portion sizes of a food frequency questionnaire applied to free-living elderly people.

    Science.gov (United States)

    Pfrimer, Karina; Sartorelli, Daniela Saes; Rosa, Flavia Troncon; Mendes Resende, Cristina Maria; Viera, Daniela Vieira Pallos; Rabito, Estela Iraci; Scagliusi, Fernanda Baeza; Moriguti, Eny Kiyomi Uemora; Monteiro, Jaqueline Pontes; Ferriolli, Eduardo

    2013-05-01

    To calibrate the food list and relative portion sizes of a food frequency questionnaire (FFQ) for application to a free-living, healthy, elderly population. Cross-sectional study. One hundred free-living, healthy participants, aged from 60 to 75 y, randomly selected from among individuals in the area served by the Family Health Program, School of Medicine of Ribeirao Preto, University of São Paulo. A Food Frequency Questionnaire (FFQ) and a Diet History Questionnaire (DH) were applied by trained dietitians. Each food item of the FFQ had its portion size recalculated according to the percentiles referenced by the volunteers in the DH (25th = small, 50th = medium, and 75th = large). The list of foods and portion sizes of the original FFQ and those obtained by the application of the DH were compared. The percent contribution of energy, protein, fat, carbohydrate, folic acid, vitamin C, calcium, and fiber of each food item mentioned in the FFQ was determined from the data obtained by the application of the DH. FFQ, as compared with the DH, provided good estimation of the intake of protein, calcium, folic acid, and fiber (paired t test P food list were found to be appropriate for application to healthy, urban, free-living elderly people in Ribeirao Preto, Brazil. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. The Impact of Nutrition and Health Claims on Consumer Perceptions and Portion Size Selection: Results from a Nationally Representative Survey

    Directory of Open Access Journals (Sweden)

    Tony Benson

    2018-05-01

    Full Text Available Nutrition and health claims on foods can help consumers make healthier food choices. However, claims may have a ‘halo’ effect, influencing consumer perceptions of foods and increasing consumption. Evidence for these effects are typically demonstrated in experiments with small samples, limiting generalisability. The current study aimed to overcome this limitation through the use of a nationally representative survey. In a cross-sectional survey of 1039 adults across the island of Ireland, respondents were presented with three different claims (nutrition claim = “Low in fat”; health claim = “With plant sterols. Proven to lower cholesterol”; satiety claim = “Fuller for longer” on four different foods (cereal, soup, lasagne, and yoghurt. Participants answered questions on perceived healthiness, tastiness, and fillingness of the products with different claims and also selected a portion size they would consume. Claims influenced fillingness perceptions of some of the foods. However, there was little influence of claims on tastiness or healthiness perceptions or the portion size selected. Psychological factors such as consumers’ familiarity with foods carrying claims and belief in the claims were the most consistent predictors of perceptions and portion size selection. Future research should identify additional consumer factors that may moderate the relationships between claims, perceptions, and consumption.

  16. The process evaluation of two interventions aimed at portion size in worksite cafeterias.

    NARCIS (Netherlands)

    Vermeer, W.M.; Leeuwis, F.H.; Koprulu, S.; Zouitni, O.; Seidell, J.C.; Steenhuis, I.H.M.

    2012-01-01

    Background: In a previous study, the effectiveness of introducing a small meal in addition to the existing size and a proportional pricing strategy have been assessed in Dutch worksite cafeterias. To assess the degree of implementation and to inform the design of future interventions, the present

  17. View the label before you view the movie: A field experiment into the impact of Portion size and Guideline Daily Amounts labelling on soft drinks in cinemas

    Directory of Open Access Journals (Sweden)

    de Boer Michiel

    2011-06-01

    Full Text Available Abstract Background Large soft drink sizes increase consumption, and thereby contribute to obesity. Portion size labelling may help consumers to select more appropriate food portions. This study aimed to assess the effectiveness of portion size and caloric Guidelines for Daily Amounts (GDA labelling on consumers' portion size choices and consumption of regular soft drinks. Methods A field experiment that took place on two subsequent evenings in a Dutch cinema. Participants (n = 101 were asked to select one of five different portion sizes of a soft drink. Consumers were provided with either portion size and caloric GDA labelling (experimental condition or with millilitre information (control condition. Results Labelling neither stimulated participants to choose small portion sizes (OR = .75, p = .61, CI: .25 - 2.25, nor did labelling dissuade participants to choose large portion sizes (OR = .51, p = .36, CI: .12 - 2.15. Conclusions Portion size and caloric GDA labelling were found to have no effect on soft drink intake. Further research among a larger group of participants combined with pricing strategies is required. The results of this study are relevant for the current public health debate on food labelling.

  18. Iceberg Semantics For Count Nouns And Mass Nouns: Classifiers, measures and portions

    Directory of Open Access Journals (Sweden)

    Fred Landman

    2016-12-01

    It is the analysis of complex NPs and their mass-count properties that is the focus of the second part of this paper. There I develop an analysis of English and Dutch pseudo- partitives, in particular, measure phrases like three liters of wine and classifier phrases like three glasses of wine. We will study measure interpretations and classifier interpretations of measures and classifiers, and different types of classifier interpretations: container interpretations, contents interpretations, and - indeed - portion interpretations. Rothstein 2011 argues that classifier interpretations (including portion interpretations of pseudo partitives pattern with count nouns, but that measure interpretations pattern with mass nouns. I will show that this distinction follows from the very basic architecture of Iceberg semantics.

  19. Does modifying the thick texture and creamy flavour of a drink change portion size selection and intake?

    Science.gov (United States)

    McCrickerd, Keri; Chambers, Lucy; Yeomans, Martin R

    2014-02-01

    Previous research indicates that a drink's sensory characteristics can influence appetite regulation. Enhancing the thick and creamy sensory characteristics of a drink generated expectations of satiety and improved its actual satiating effects. Expectations about food also play an important role in decisions about intake, in which case enhancing the thick and creamy characteristics of a drink might also result in smaller portion size selection. In the current study forty-eight participants (24 female) completed four test days where they came into the laboratory for a fixed-portion breakfast, returning two hours later for a mid-morning drink, which they could serve themselves and consume as much as they liked. Over the test days, participants consumed an iso-energetic drink in four sensory contexts: thin and low-creamy; thin and high-creamy; thick and low-creamy; thick and high-creamy. Results indicated that participants consumed less of the thick drinks, but that this was only true of the female participants; male participants consumed the same amount of the four drinks regardless of sensory context. The addition of creamy flavour did not affect intake but the thicker drinks were associated with an increase in perceived creaminess. Despite differences in intake, hunger and fullness ratings did not differ across male and female participants and were not affected by the drinks sensory characteristics. The vast majority of participants consumed all of the drink they served themselves indicating that differences in intake reflected portion size decisions. These findings suggest women will select smaller portions of a drink when its sensory characteristics indicate that it will be satiating. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Estimated portion sizes of snacks and beverages differ from reference amounts and are affected by appetite status in non-obese men.

    Science.gov (United States)

    Brogden, Nina; Almiron-Roig, Eva

    2011-10-01

    To explore the extent to which appetite status influences portion size estimation in men under laboratory conditions and to quantify how much participants' portion estimates differed from the recommended portion sizes defined by authoritative bodies (i.e. government and health professionals' reference amounts). Repeated, randomized cross-over trial with each participant attending the laboratory on four separate occasions. At each session, participants rated the number of portions of eight foods and beverages displayed in front of them. Participants rated portions twice after consuming breakfast (full conditions) and twice after an overnight fast (hungry conditions). Portion estimates were compared with reference amounts from the British and American Dietetic Associations, from the UK Food Standards Agency and from the US Food and Drug Administration. Food skills laboratory, University of Chester, UK. Twenty-seven non-obese men (mean age 24·9 (sd 6·5) years). Portion size estimates for all items were significantly smaller under hungry than under full conditions (P portion and recommendations from health professionals and government standards. Nutritional educational strategies should take into account the role of hunger along with a person's familiarity with existing portion size systems when advising on portion sizes.

  1. Is portion size selection associated with expected satiation, perceived healthfulness or expected tastiness? A case study on pizza using a photograph-based computer task.

    Science.gov (United States)

    Labbe, D; Rytz, A; Godinot, N; Ferrage, A; Martin, N

    2017-01-01

    Increasing portion sizes over the last 30 years are considered to be one of the factors underlying overconsumption. Past research on the drivers of portion selection for foods showed that larger portions are selected for foods delivering low expected satiation. However, the respective contribution of expected satiation vs. two other potential drivers of portion size selection, i.e. perceived healthfulness and expected tastiness, has never been explored. In this study, we conjointly explored the role of expected satiation, perceived healthfulness and expected tastiness when selecting portions within a range of six commercial pizzas varying in their toppings and brands. For each product, 63 pizza consumers selected a portion size that would satisfy them for lunch and scored their expected satiation, perceived healthfulness and expected tastiness. As six participants selected an entire pizza as ideal portion independently of topping or brand, their data sets were not considered in the data analyses completed on responses from 57 participants. Hierarchical multiple regression analyses showed that portion size variance was predicted by perceived healthiness and expected tastiness variables. Two sub-groups of participants with different portion size patterns across pizzas were identified through post-hoc exploratory analysis. The explanatory power of the regression model was significantly improved by adding interaction terms between sub-group and expected satiation variables and between sub-group and perceived healthfulness variables to the model. Analysis at a sub-group level showed either positive or negative association between portion size and expected satiation depending on sub-groups. For one group, portion size selection was more health-driven and for the other, more hedonic-driven. These results showed that even when considering a well-liked product category, perceived healthfulness can be an important factor influencing portion size decision. Copyright © 2016

  2. The Effect of Eating Style and Portion Size on the Accuracy of Dietary Self-Monitoring Among Normal Weight and Overweight Women

    Science.gov (United States)

    2007-07-23

    135 Appendix B: Advertisements ...interviews, dietary recall, and food frequency questionnaires (FFQ); Block, 1982; Marr, 1971; Young & Nestle , 1995). Prospective methods are methods...available food portions exceed USDA and FDA standard sizes, and most foods are available in larger portion sizes than in the 1970s (Young & Nestle , 2002). A

  3. "It was an education in portion size". Experience of eating a healthy diet and barriers to long term dietary change.

    Science.gov (United States)

    Macdiarmid, J I; Loe, J; Kyle, J; McNeill, G

    2013-12-01

    The aim of the study was to explore the expectations and experience of actually eating a healthy diet and using this experience to identify barriers to healthy eating and sustainable dietary change. Fifty participants (19-63 yrs) were provided with a healthy diet (i.e. complied with dietary recommendations) for three consecutive days. Afterwards a semi-structured interview was carried out to explore expectations, experience and barriers to healthy eating. Using a thematic analysis approach eight dominant themes emerged from the interviews. Four related to expectations and experience of healthy eating; realisation of what are appropriate portion sizes, an expectation to feel hungry, surprise that healthy diets comprised normal food, the desire for sweet snacks (e.g. chocolate). This demonstrated there are some misconception about healthy eating and distorted views of portion size. Four more themes emerged relating to barriers to healthy eating; competing priorities, social, peer and time pressure, importance of value for money, a lack of desire to cook. Poor knowledge of healthy eating or a lack of cooking skills were the least common barrier, suggesting that future interventions and policy to improve dietary intakes need to focus on social, cultural and economic issues rather than on lack of knowledge or skills. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  5. Assessing intake of spices by pattern of spice use, frequency of consumption and portion size of spices consumed from routinely prepared dishes in southern India.

    Science.gov (United States)

    Siruguri, Vasanthi; Bhat, Ramesh V

    2015-01-11

    Measurement of dietary intake of spices is gaining significance because of recognition of their health promoting benefits as well as its use for risk assessment of contaminant exposures. Estimating intake of spices at the individual level, presents several challenges since various spices are used as an integrated part of a prepared food and consumed in amounts much smaller than other dietary components. The objective of the present study is to assess intake of spices at the household and individual level on the basis of pattern of spice use and portion size of spice consumed from routinely prepared dishes in Hyderabad city in Southern India. The study was conducted in 100 households in urban areas of Hyderabad city in India with the help of a spice intake questionnaire that was prepared to collect information on the pattern of spice use, frequency, and quantity of spice consumption of 17 spices routinely used in Indian cuisine. The quantity of spice intake was assessed by measuring portion size of spice consumed from the quantity of i) spices added in routinely prepared dishes and ii) the prepared dish consumed by an individual. Based on the type of dish prepared and frequency of preparing the dishes, 11 out of 17 spices were found to be consumed by more than 50% of the households. Maximum number of spices was consumed at weekly frequencies. Red chillies and turmeric were the most frequently consumed spices by 100% of the households. The mean total intake of spices was observed to be higher through dishes consumed daily (10.4 g/portion) than from those consumed at weekly or monthly frequencies. Highest portion size intake was observed for chillies (mean 3.0 g; range 0.05-20.2 g) and lowest for nutmeg (mean 0.14 g; range 0.02-0.64 g) and mace (mean 0.21 g; range: 0.02-0.6 g). The study suggested that assessment of intake of spices varies with frequency of use of spices and type of dish consumed. Portion size estimations of spices consumed and the frequency of

  6. Portion Size Versus Serving Size

    Science.gov (United States)

    ... Check Recipe Certification Program Nutrition Requirements Heart-Check Professional Resources Contact the Heart-Check Certification Program Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering ...

  7. Brain regions implicated in inhibitory control and appetite regulation are activated in response to food portion size and energy density in children

    NARCIS (Netherlands)

    English, L.K.; Fearnbach, S.N.; Lasschuijt, M.; Schlegel, A.; Anderson, K.; Harris, S.; Fisher, J.O.; Savage, J.S.; Rolls, B.J.; Keller, K.L.

    2016-01-01

    Objective:Large portions of energy-dense foods drive energy intake but the brain mechanisms underlying this effect are not clear. Our main objective was to investigate brain function in response to food images varied by portion size (PS) and energy density (ED) in children using functional

  8. Automated measurement of diatom size

    Science.gov (United States)

    Spaulding, Sarah A.; Jewson, David H.; Bixby, Rebecca J.; Nelson, Harry; McKnight, Diane M.

    2012-01-01

    Size analysis of diatom populations has not been widely considered, but it is a potentially powerful tool for understanding diatom life histories, population dynamics, and phylogenetic relationships. However, measuring cell dimensions on a light microscope is a time-consuming process. An alternative technique has been developed using digital flow cytometry on a FlowCAM® (Fluid Imaging Technologies) to capture hundreds, or even thousands, of images of a chosen taxon from a single sample in a matter of minutes. Up to 30 morphological measures may be quantified through post-processing of the high resolution images. We evaluated FlowCAM size measurements, comparing them against measurements from a light microscope. We found good agreement between measurement of apical cell length in species with elongated, straight valves, including small Achnanthidium minutissimum (11-21 µm) and largeDidymosphenia geminata (87–137 µm) forms. However, a taxon with curved cells, Hannaea baicalensis (37–96 µm), showed differences of ~ 4 µm between the two methods. Discrepancies appear to be influenced by the choice of feret or geodesic measurement for asymmetric cells. We describe the operating conditions necessary for analysis of size distributions and present suggestions for optimal instrument conditions for size analysis of diatom samples using the FlowCAM. The increased speed of data acquisition through use of imaging flow cytometers like the FlowCAM is an essential step for advancing studies of diatom populations.

  9. Quantifying consumer portion control practices

    DEFF Research Database (Denmark)

    Spence, M.; Lähteenmäki, Liisa; Stancu, Violeta

    2015-01-01

    of Ireland. Three factors were extracted and named: measurement-strategy scale, eating-strategy scale, and purchasing-strategy scale. The eating-strategy scale score was the highest, while the measurement-strategy scale carried the lowest frequency score. For each strategy scale score, the strongest...... predictor was GHI, followed by gender. Having higher GHI and being female were independently associated with more frequent portion control. Both the eating-strategy scale score and the purchasing-strategy scale score were negatively associated with pizza portion size consumption estimates. In conclusion......, while this study demonstrates that the reported use of portion control practices is low, the findings provide preliminary evidence for their validity. Further studies are needed to explore how portion control practices are used in different kinds of portion size decisions and what their contribution...

  10. How accurate are adolescents in portion-size estimation using the computer tool young adolescents' nutrition assessment on computer (YANA-C)?

    OpenAIRE

    Vereecken, Carine; Dohogne, Sophie; Covents, Marc; Maes, Lea

    2010-01-01

    Computer-administered questionnaires have received increased attention for large-scale population research on nutrition. In Belgium-Flanders, Young Adolescents' Nutrition Assessment on Computer (YANA-C) has been developed. In this tool, standardised photographs are available to assist in portion-size estimation. The purpose of the present study is to assess how accurate adolescents are in estimating portion sizes of food using YANA-C. A convenience sample, aged 11-17 years, estimated the amou...

  11. Measuring fire size in tunnels

    International Nuclear Information System (INIS)

    Guo, Xiaoping; Zhang, Qihui

    2013-01-01

    A new measure of fire size Q′ has been introduced in longitudinally ventilated tunnel as the ratio of flame height to the height of tunnel. The analysis in this article has shown that Q′ controls both the critical velocity and the maximum ceiling temperature in the tunnel. Before the fire flame reaches tunnel ceiling (Q′ 1.0), Fr approaches a constant value. This is also a well-known phenomenon in large tunnel fires. Tunnel ceiling temperature shows the opposite trend. Before the fire flame reaches the ceiling, it increases very slowly with the fire size. Once the flame has hit the ceiling of tunnel, temperature rises rapidly with Q′. The good agreement between the current prediction and three different sets of experimental data has demonstrated that the theory has correctly modelled the relation among the heat release rate of fire, ventilation flow and the height of tunnel. From design point of view, the theoretical maximum of critical velocity for a given tunnel can help to prevent oversized ventilation system. -- Highlights: • Fire sizing is an important safety measure in tunnel design. • New measure of fire size a function of HRR of fire, tunnel height and ventilation. • The measure can identify large and small fires. • The characteristics of different fire are consistent with observation in real fires

  12. Reliability and Validity of Digital Imagery Methodology for Measuring Starting Portions and Plate Waste from School Salad Bars.

    Science.gov (United States)

    Bean, Melanie K; Raynor, Hollie A; Thornton, Laura M; Sova, Alexandra; Dunne Stewart, Mary; Mazzeo, Suzanne E

    2018-04-12

    Scientifically sound methods for investigating dietary consumption patterns from self-serve salad bars are needed to inform school policies and programs. To examine the reliability and validity of digital imagery for determining starting portions and plate waste of self-serve salad bar vegetables (which have variable starting portions) compared with manual weights. In a laboratory setting, 30 mock salads with 73 vegetables were made, and consumption was simulated. Each component (initial and removed portion) was weighed; photographs of weighed reference portions and pre- and post-consumption mock salads were taken. Seven trained independent raters visually assessed images to estimate starting portions to the nearest ¼ cup and percentage consumed in 20% increments. These values were converted to grams for comparison with weighed values. Intraclass correlations between weighed and digital imagery-assessed portions and plate waste were used to assess interrater reliability and validity. Pearson's correlations between weights and digital imagery assessments were also examined. Paired samples t tests were used to evaluate mean differences (in grams) between digital imagery-assessed portions and measured weights. Interrater reliabilities were excellent for starting portions and plate waste with digital imagery. For accuracy, intraclass correlations were moderate, with lower accuracy for determining starting portions of leafy greens compared with other vegetables. However, accuracy of digital imagery-assessed plate waste was excellent. Digital imagery assessments were not significantly different from measured weights for estimating overall vegetable starting portions or waste; however, digital imagery assessments slightly underestimated starting portions (by 3.5 g) and waste (by 2.1 g) of leafy greens. This investigation provides preliminary support for use of digital imagery in estimating starting portions and plate waste from school salad bars. Results might inform

  13. Effect of portion size and milk flow on the use of a milk feeder and the development of cross-sucking in dairy calves

    DEFF Research Database (Denmark)

    Nielsen, Per Peetz; Jensen, Margit Bak; Halekoh, Ulrich

    2018-01-01

    milk feeder in each pen, and exposed to four milk-feeding treatments in a cross-over design with four periods of 1 week. All four treatments involved a daily allowance of 8. L of whole milk, with variation in the maximum portion size and the rate at which milk entered the teat of the milk feeder......This study aimed to investigate whether reducing the milk flow and increasing the milk portion size of a computer-controlled milk feeder would lead to less cross-sucking and fewer unrewarded feeder visits in dairy calves. Five groups, each with 9 or 10 calves (n = 48), were housed in pens with one...

  14. Evidenced-based, practical food portion sizes for preschool children and how they fit into a well balanced, nutritionally adequate diet.

    Science.gov (United States)

    More, J A; Emmett, P M

    2015-04-01

    Healthy eating guidelines for 1-4-year-old children are available but evidence-based portion sizes have not been specified. Parents and early-years providers are concerned about under- or over-feeding young children. The present study aimed to report detailed information about appropriate average portion size ranges and suggest a practical food plan for feeding preschool children, providing adequate nutrient intakes within energy requirements. Two sources of information were used to obtain an appropriate portion size range for the types of foods normally eaten by this age group. Median portions of a variety of foods were combined into a food plan fulfilling healthy eating guidelines regarding the number of servings from each food group. The nutrient and energy content of the plan was assessed and compared with recommended adequate nutrient intakes and percentage energy contributions from macronutrients. UK children, aged 1-4 years, taking part in Avon Longitudinal Study of Parents and Children and National Diet and Nutrition Survey, were used in the present study. Portion size ranges were developed for 164 foods. The theoretical food plan using foods with high to medium nutrient density was shown to provide an adequate intake of all nutrients, except vitamin D, for which there are very few food sources. These practical food portion size ranges could be used both in early years settings and in advice to parents. The food plan emphasises the need to include a variety of nutrient-dense foods if a balanced diet is to be achieved for preschool children. © 2014 The British Dietetic Association Ltd.

  15. How accurate are adolescents in portion-size estimation using the computer tool Young Adolescents' Nutrition Assessment on Computer (YANA-C)?

    Science.gov (United States)

    Vereecken, Carine; Dohogne, Sophie; Covents, Marc; Maes, Lea

    2010-06-01

    Computer-administered questionnaires have received increased attention for large-scale population research on nutrition. In Belgium-Flanders, Young Adolescents' Nutrition Assessment on Computer (YANA-C) has been developed. In this tool, standardised photographs are available to assist in portion-size estimation. The purpose of the present study is to assess how accurate adolescents are in estimating portion sizes of food using YANA-C. A convenience sample, aged 11-17 years, estimated the amounts of ten commonly consumed foods (breakfast cereals, French fries, pasta, rice, apple sauce, carrots and peas, crisps, creamy velouté, red cabbage, and peas). Two procedures were followed: (1) short-term recall: adolescents (n 73) self-served their usual portions of the ten foods and estimated the amounts later the same day; (2) real-time perception: adolescents (n 128) estimated two sets (different portions) of pre-weighed portions displayed near the computer. Self-served portions were, on average, 8 % underestimated; significant underestimates were found for breakfast cereals, French fries, peas, and carrots and peas. Spearman's correlations between the self-served and estimated weights varied between 0.51 and 0.84, with an average of 0.72. The kappa statistics were moderate (>0.4) for all but one item. Pre-weighed portions were, on average, 15 % underestimated, with significant underestimates for fourteen of the twenty portions. Photographs of food items can serve as a good aid in ranking subjects; however, to assess the actual intake at a group level, underestimation must be considered.

  16. Single-larger-portion-size and dual-column nutrition labeling may help consumers make more healthful food choices.

    Science.gov (United States)

    Lando, Amy M; Lo, Serena C

    2013-02-01

    The Food and Drug Administration is considering changes to the Nutrition Facts label to help consumers make more healthful choices. To examine the effects of modifications to the Nutrition Facts label on foods that can be listed as having 1 or 2 servings per container, but are reasonably consumed at a single eating occasion. Participants were randomly assigned to study conditions that varied on label format, product, and nutrition profile. Data were collected via an online consumer panel. Adults aged 18 years and older were recruited from Synovate's online household panel. Data were collected during August 2011. A total of 32,897 invitations were sent for a final sample of 9,493 interviews. Participants were randomly assigned to one of 10 label formats classified into three groups: listing 2 servings per container with a single column, listing 2 servings per container with a dual column, and listing a single serving per container. Within these groups there were versions that enlarged the font size for "calories," removed "calories from fat," and changed the wording for serving size declaration. The single product task measured product healthfulness, the amount of calories and various nutrients per serving and per container, and label perceptions. The product comparison task measured ability to identify the healthier product and the product with fewer calories per container and per serving. Analysis of covariance models with Tukey-Kramer tests were used. Covariates included general label use, age, sex, level of education, and race/ethnicity. Single-serving and dual-column formats performed better and scored higher on most outcome measures. For products that contain 2 servings but are customarily consumed at a single eating occasion, using a single-serving or dual-column labeling approach may help consumers make healthier food choices. Published by Elsevier Inc.

  17. Food photographs in nutritional surveillance: errors in portion size estimation using drawings of bread and photographs of margarine and beverages consumption

    NARCIS (Netherlands)

    Keyzer, de W.; Huybrechts, I.; Maeyer, de M.; Ocke, M.C.; Slimani, N.; Veer, van 't P.; Henauw, de S.

    2011-01-01

    Food photographs are widely used as instruments to estimate portion sizes of consumed foods. Several food atlases are available, all developed to be used in a specific context and for a given study population. Frequently, food photographs are adopted for use in other studies with a different context

  18. Nutrition Labeling and Portion Size Information on Children's Menus in Fast-Food and Table-Service Chain Restaurants in London, UK

    Science.gov (United States)

    Reeves, Sue; Wake, Yvonne; Zick, Andrea

    2011-01-01

    Objective: To investigate meals, price, nutritional content, and nutrition and portion size information available on children's menus in fast-food and table-service chain restaurants in London, since the United Kingdom does not currently require such information but may be initiating a voluntary guideline. Methods: Children's menus were assessed…

  19. Food photographs in nutritional surveillance: errors in portion size estimation using drawings of bread and photographs of margarine and beverages consumption.

    Science.gov (United States)

    De Keyzer, Willem; Huybrechts, Inge; De Maeyer, Mieke; Ocké, Marga; Slimani, Nadia; van 't Veer, Pieter; De Henauw, Stefaan

    2011-04-01

    Food photographs are widely used as instruments to estimate portion sizes of consumed foods. Several food atlases are available, all developed to be used in a specific context and for a given study population. Frequently, food photographs are adopted for use in other studies with a different context or another study population. In the present study, errors in portion size estimation of bread, margarine on bread and beverages by two-dimensional models used in the context of a Belgian food consumption survey are investigated. A sample of 111 men and women (age 45-65 years) were invited for breakfast; two test groups were created. One group was asked to estimate portion sizes of consumed foods using photographs 1-2 d after consumption, and a second group was asked the same after 4 d. Also, real-time assessment of portion sizes using photographs was performed. At the group level, large overestimation of margarine, acceptable underestimation of bread and only small estimation errors for beverages were found. Women tended to have smaller estimation errors for bread and margarine compared with men, while the opposite was found for beverages. Surprisingly, no major difference in estimation error was found after 4 d compared with 1-2 d. Individual estimation errors were large for all foods. The results from the present study suggest that the use of food photographs for portion size estimation of bread and beverages is acceptable for use in nutrition surveys. For photographs of margarine on bread, further validation using smaller amounts corresponding to actual consumption is recommended.

  20. Eating habits of a population undergoing a rapid dietary transition: portion sizes of traditional and non-traditional foods and beverages consumed by Inuit adults in Nunavut, Canada

    Science.gov (United States)

    2013-01-01

    Background To determine the portion sizes of traditional and non-traditional foods being consumed by Inuit adults in three remote communities in Nunavut, Canada. Methods A cross-sectional study was carried out between June and October, 2008. Trained field workers collected dietary data using a culturally appropriate, validated quantitative food frequency questionnaire (QFFQ) developed specifically for the study population. Results Caribou, muktuk (whale blubber and skin) and Arctic char (salmon family), were the most commonly consumed traditional foods; mean portion sizes for traditional foods ranged from 10 g for fermented seal fat to 424 g for fried caribou. Fried bannock and white bread were consumed by >85% of participants; mean portion sizes for these foods were 189 g and 70 g, respectively. Sugar-sweetened beverages and energy-dense, nutrient-poor foods were also widely consumed. Mean portion sizes for regular pop and sweetened juices with added sugar were 663 g and 572 g, respectively. Mean portion sizes for potato chips, pilot biscuits, cakes, chocolate and cookies were 59 g, 59 g, 106 g, 59 g, and 46 g, respectively. Conclusions The present study provides further evidence of the nutrition transition that is occurring among Inuit in the Canadian Arctic. It also highlights a number of foods and beverages that could be targeted in future nutritional intervention programs aimed at obesity and diet-related chronic disease prevention in these and other Inuit communities. PMID:23724920

  1. Ingredients of gender-based stereotypes about food. Indirect influence of food type, portion size and presentation on gendered intentions to eat.

    Science.gov (United States)

    Cavazza, Nicoletta; Guidetti, Margherita; Butera, Fabrizio

    2015-08-01

    The association between certain foods and masculinity or femininity has been widely discussed in different disciplines. However, extant research has yet to clarify which are the critical dimensions lending these gender connotations to food and thus impacting on the willingness to eat it. We present a study on the role of food type, portion size, and dish presentation as potential factors constituting the gender-based stereotype about food, and their indirect or mediated effect on the intention of men and women to eat certain feminine/masculine stereotyped foods. We manipulated the three features cited above in a 2 (food type: Caprese vs. hamburger) × 2 (portion size: small vs. big) × 2 (presentation: elegant vs. rough) full factorial design. Results confirmed a model of moderated mediation: the Caprese salad, the small portion and the elegantly presented dish (in respect to the hamburger, the big portion and the roughly presented dish) tend to be considered "feminine food", and thus women expressed a more pronounced intention to eat it than men. The implications of the findings for both theory and practice are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Public Health and Legal Arguments in Favor of a Policy to Cap the Portion Sizes of Sugar-Sweetened Beverages.

    Science.gov (United States)

    Roberto, Christina A; Pomeranz, Jennifer L

    2015-11-01

    In 2012, the New York City Board of Health passed a regulation prohibiting the sale of sugar-sweetened beverages in containers above 16 ounces in the city's food service establishments. The beverage industry and various retailers sued the city to prevent enforcement of the law, arguing that the board had overstepped its authority. In June 2014, the state's highest court agreed and struck down the regulation. Here we report the results of a content analysis of the public testimony related to the case submitted to the New York City Department of Mental Health and Hygiene. We identified major arguments in support of and against the sugar-sweetened beverage portion limit policy. We offer legal and scientific arguments that challenge the major anti-policy arguments and contend that, although this policy was not implemented in New York City, it can be legally pursued by other legislatures.

  3. Development and validation of a food photography manual, as a tool for estimation of food portion size in epidemiological dietary surveys in Tunisia

    Directory of Open Access Journals (Sweden)

    Mongia Bouchoucha

    2016-08-01

    Full Text Available Background: Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods: A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos to the reference method [food weighing (FW]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland–Altman limits of agreement. In total, 31 male and female volunteers aged 9–89 participated in the study. Results: We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method to those actually consumed (using FW. Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05 and dairy products (p<0.05. The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001 and dietary fiber (p<0.05. A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion: The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.

  4. Development and validation of a food photography manual, as a tool for estimation of food portion size in epidemiological dietary surveys in Tunisia.

    Science.gov (United States)

    Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir

    2016-01-01

    Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.

  5. Gender differences in dietary intake among adults of Hindu communities in lowland Nepal: assessment of portion sizes and food consumption frequencies.

    Science.gov (United States)

    Sudo, N; Sekiyama, M; Maharjan, M; Ohtsuka, R

    2006-04-01

    To elucidate gender differences in dietary intake among adults in lowland Nepalese communities. For 122 male and 195 female subjects aged 20 years and over from 94 randomly selected households, interviews using a 19-item food frequency questionnaire were conducted. To determine the portion sizes of these foods, the samples consumed by 56 subjects in a full 1-day period were weighed. Energy expenditure was estimated by time spent on daily activities. Gender differences in per-day energy and protein intakes were related to sex differences in body size and energy expenditure. Apparent gender differences in the crude intakes disappeared when they were expressed by nutrient density (mg or microg/MJ) since micronutrient intakes were significantly correlated with energy intake. However, males' iron intake was larger even after adjustment for energy intake, attributing to their larger portion sizes of commonly consumed staple foods and higher frequencies of consuming luxury foods (fish and tea). The intrahousehold unequal distribution of food incurs risk of iron deficiency among female subjects. This study was financially supported by the Ajinomoto Foundation for Dietary Culture and the Alliance for Global Sustainability Program.

  6. Caloric effect of a 16-ounce (473-mL) portion-size cap on sugar-sweetened beverages served in restaurants.

    Science.gov (United States)

    Wang, Y Claire; Vine, Seanna M

    2013-08-01

    New York City recently proposed a restriction to cap the portion size of all sugar-sweetened beverages (SSBs) sold in food-service establishments at 16 oz (473 mL). One critical question is whether such a policy may disproportionally affect low-income or overweight individuals. The objective was to determine the demographic characteristics of US individuals potentially affected by a 16-oz portion-size cap on SSBs and the potential effect on caloric intake. We analyzed dietary records from the NHANES 2007-2010. We estimated the proportion of individuals who consumed at least one SSB >16 fluid oz (473 mL) in restaurants by age, household income, and weight status. Of all SSBs >16 oz (473 mL) purchased from food-service establishments, 64.7% were purchased from fast food restaurants, 28.2% from other restaurants, and 4.6% from sports, recreation, and entertainment facilities. On a given day, the policy would affect 7.2% of children and 7.6% of adults. Overweight individuals are more likely to consume these beverages, whereas there was no significant difference between income groups. If 80% of affected consumers choose a 16-oz (473-mL) beverage, the policy would result in a change of -57.6 kcal in each affected consumer aged 2-19 y (95% CI: -65.0, -50.1) and -62.6 kcal in those aged ≥20 y (95% CI: -67.9, -57.4). A policy to cap portion size is likely to result in a modest reduction in excess calories from SSBs, especially among young adults and children who are overweight.

  7. Brain regions implicated in inhibitory control and appetite regulation are activated in response to food portion size and energy density in children.

    Science.gov (United States)

    English, L K; Fearnbach, S N; Lasschuijt, M; Schlegel, A; Anderson, K; Harris, S; Wilson, S J; Fisher, J O; Savage, J S; Rolls, B J; Keller, K L

    2016-10-01

    Large portions of energy-dense foods drive energy intake but the brain mechanisms underlying this effect are not clear. Our main objective was to investigate brain function in response to food images varied by portion size (PS) and energy density (ED) in children using functional magnetic resonance imaging (fMRI). Blood-oxygen-level-dependent (BOLD) fMRI was completed in 36 children (ages 7-10 years) after a 2-h fast while viewing food images at two levels of PS (Large PS, Small PS) and two levels of ED (High ED, Low ED). Children rated perceived fullness pre- and post-fMRI, as well as liking of images on visual analog scales post-fMRI. Anthropometrics were completed 4 weeks before the fMRI. Large PS vs Small PS and High ED vs Low ED were compared with region-of-interest analyses using Brain Voyager v 2.8. Region-of-interest analyses revealed that activation in the right inferior frontal gyrus (P=0.03) was greater for Large PS vs Small PS. Activation was reduced for High ED vs Low ED in the left hypothalamus (P=0.03). Main effects were no longer significant after adjustment for pre-fMRI fullness and liking ratings (PS, P=0.92; ED, P=0.58). This is the first fMRI study to report increased activation to large portions in a brain region that is involved in inhibitory control. These findings may contribute to understanding why some children overeat when presented with large portions of palatable food.

  8. Disruption effects on the beam size measurement

    International Nuclear Information System (INIS)

    Raimondi, P.; Decker, F.J.; Chen, P.

    1995-01-01

    At the SLC Final Focus with higher currents and smaller beam sizes, the disruption parameter D y is close to one and so the pinch effect should produce a luminosity enhancement. Since a flat beam-beam function is fit to deflection scan data to measure the beam size, disruption can affect the measurement. Here the authors discuss the quantitative effects of disruption for typical SLC beam parameters. With 3.5 10 10 particles per pulse, bunch length of 0.8 mm and beam sizes of 2.1 μm horizontally and 0.55 μm vertically, the measured vertical size can be as much as 25% bigger than the real one. Furthermore during the collision the spot size actually decrease, producing an enhancement factor H D of about 1.25. This would yield to a true luminosity which is 1.6 times that which is estimated from the beam-beam deflection fit

  9. Calculation and measurement of fog droplet size

    International Nuclear Information System (INIS)

    Laali, A.R.; Courant, J.J.; Kleitz, A.

    1991-01-01

    This paper outlines the elements involved in calculation and measurement of fog droplet size in steam turbines. The condensation calculations are performed for a 600 MW LP fossil fired, and for a 900 MW LP nuclear turbine. A simplified method based on classical condensation theory is used for these calculations. The fog droplet size measurement are carried out downstream of the last moving blades of these turbines in order to validate the program. The comparison between the results could lead to a better understanding of the condensation process in steam turbines. Some large droplet (re-entrained droplet) measurements are also taken using a microvideo probe

  10. Keeping Portions Under Control (For Parents)

    Science.gov (United States)

    ... it possible to bring portion sizes back to earth? Yes. But first we have to understand how ... recommend for a portion of pasta, rice, cereal, vegetables, and fruit. A meat portion should be about ...

  11. Measuring wage effects of plant size

    DEFF Research Database (Denmark)

    Albæk, Karsten; Arai, Mahmood; Asplund, Rita

    1998-01-01

    There are large plant size–wage effects in the Nordic countries after taking into account individual and job characteristics as well as systematical sorting of the workers into various plant-sizes. The plant size–wage elasticities we obtain are, in contrast to other dimensions of the wage distrib......–wage elasticity. Our results indicate that using size–class midpoints yields essentially the same results as using exact measures of plant size...

  12. Do Effect-Size Measures Measure up?: A Brief Assessment

    Science.gov (United States)

    Onwuegbuzie, Anthony J.; Levin, Joel R.; Leech, Nancy L.

    2003-01-01

    Because of criticisms leveled at statistical hypothesis testing, some researchers have argued that measures of effect size should replace the significance-testing practice. We contend that although effect-size measures have logical appeal, they are also associated with a number of limitations that may result in problematic interpretations of them…

  13. Disruption effects on the beam size measurement

    Energy Technology Data Exchange (ETDEWEB)

    Raimondi, P.; Decker, F.J.; Chen, P.

    1995-06-01

    At the SLC Final Focus with higher currents and smaller beam sizes, the disruption parameter D{sub y} is close to one and so the pinch effect should produce a luminosity enhancement. Since a flat beam-beam function is fit to deflection scan data to measure the beam size, disruption can affect the measurement. Here the authors discuss the quantitative effects of disruption for typical SLC beam parameters. With 3.5 10{sup 10} particles per pulse, bunch length of 0.8 mm and beam sizes of 2.1 {mu}m horizontally and 0.55 {mu}m vertically, the measured vertical size can be as much as 25% bigger than the real one. Furthermore during the collision the spot size actually decrease, producing an enhancement factor H{sub D} of about 1.25. This would yield to a true luminosity which is 1.6 times that which is estimated from the beam-beam deflection fit.

  14. Drop size measurements in Venturi scrubbers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Alonso, D.; Azzopardi, B.J. [Nottingham Univ. (United Kingdom). Dept. of Chemical Engineering; Goncalves, J.A.S.; Coury, J.R. [Universidade Federal de Sao Carlos (Brazil). Departamento de Engenharia Quimica

    2001-07-01

    Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by drops formed by liquid atomisation, usually in the Venturi throat. The size of the drops formed are of fundamental importance to the performance of the equipment, both in terms of pressure drop and dust removal efficiency. In this study, drop sizes in a cylindrical laboratory-scale Venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 1/m{sup 3}, respectively. Water was injected using two different arrangements: either as jets in the throat or as a film just upstream of the convergence. Drop size measurements were performed at three positions in the case of jet injection: two located along the throat, and the last one at the end of the diffuser. The present data shows that the Sauter mean diameter of the spray can be well correlated by the equation of Boll et al. (J. Air Pollut. Control Assoc. 24 (1974) 932). Drop size distributions are satisfactorily represented by a Rosin-Rammler function. This paper also provides a simple method for calculating the parameters of the Rosin-Rammler function. As a result of this work, drop sizes in Venturi scrubbers can be estimated with much higher accuracy. (Author)

  15. Reduction of Portion Size and Eating Rate Is Associated with BMI-SDS Reduction in Overweight and Obese Children and Adolescents: Results on Eating and Nutrition Behaviour from the Observational KgAS Study.

    Science.gov (United States)

    Torbahn, Gabriel; Gellhaus, Ines; Koch, Benjamin; von Kries, Rüdiger; Obermeier, Viola; Holl, Reinhard W; Fink, Katharina; van Egmond-Fröhlich, Andreas

    2017-01-01

    Treatment of paediatric obesity focuses on changes of nutrition and eating behaviour and physical activity. The evaluation of the patient education programme by KgAS was utilised to analyse the association of changes of portion size, eating rate and dietary habits with BMI-SDS reductions. Patients (n = 297) were examined at the beginning and at the end of treatment and after 1-year follow-up at different out-patient centres. Their parents completed questionnaires including estimation of children's portion size, eating rate and frequency of food intake. Associations of 1- and 2-year changes in BMI-SDS and behaviour were calculated for patients with complete data in BMI-SDS, portion size, eating rate, frequency of green, yellow and red food intake (n = 131) by multiple linear regression models. Significant changes were found in the desired direction for BMI-SDS, portion size, eating rate and the intake of unfavourable red food items both after 1 and 2 years as well as for the consumption of favourable green food items after 1 year. Significant positive associations with BMI-SDS reduction after 1 and 2 years were detected for portion size (Cohen's f2 0.13 and 0.09) and eating rate (Cohen's f2 0.20 and 0.10), respectively. Reduced portion sizes and eating rates are associated with BMI-SDS reduction after 1 and 2 years. These findings suggest to focus on appropriate portion sizes and reduced eating rates in patient education programmes. © 2017 The Author(s) Published by S. Karger GmbH, Freiburg.

  16. Reduction of Portion Size and Eating Rate Is Associated with BMI-SDS Reduction in Overweight and Obese Children and Adolescents: Results on Eating and Nutrition Behaviour from the Observational KgAS Study

    Directory of Open Access Journals (Sweden)

    Gabriel Torbahn

    2017-10-01

    Full Text Available Objective: Treatment of paediatric obesity focuses on changes of nutrition and eating behaviour and physical activity. The evaluation of the patient education programme by KgAS was utilised to analyse the association of changes of portion size, eating rate and dietary habits with BMI-SDS reductions. Methods: Patients (n = 297 were examined at the beginning and at the end of treatment and after 1-year follow-up at different out-patient centres. Their parents completed questionnaires including estimation of children's portion size, eating rate and frequency of food intake. Associations of 1- and 2-year changes in BMI-SDS and behaviour were calculated for patients with complete data in BMI-SDS, portion size, eating rate, frequency of green, yellow and red food intake (n = 131 by multiple linear regression models. Results: Significant changes were found in the desired direction for BMI-SDS, portion size, eating rate and the intake of unfavourable red food items both after 1 and 2 years as well as for the consumption of favourable green food items after 1 year. Significant positive associations with BMI-SDS reduction after 1 and 2 years were detected for portion size (Cohen's f2 0.13 and 0.09 and eating rate (Cohen's f2 0.20 and 0.10, respectively. Conclusion: Reduced portion sizes and eating rates are associated with BMI-SDS reduction after 1 and 2 years. These findings suggest to focus on appropriate portion sizes and reduced eating rates in patient education programmes.

  17. Conception, definition, measuring procedure of grain size

    International Nuclear Information System (INIS)

    Yanagisawa, Kazuaki

    1976-12-01

    The conception, definition, measuring procedure of ''Grain Size'' were surveyed. A concept ''grain diameter'' was introduced after deriving a calculation formula for the grain diameter for using the Comparison (simple) and Intercept(detailed) procedure. As an example and putting into practice, the grain diameter determination was carried out by means of the Comparison procedure for a UO 2 pellet used in a densification experiment. (auth.)

  18. Size and velocity measurements in combustion systems

    International Nuclear Information System (INIS)

    Levy, Y.; Timnat, Y.M.

    1986-01-01

    Two-phase flow measurements for size and velocity determination in combustion systems are discussed: the pedestal technique and phase Doppler anemometry (PDA) are described in detail. The experimental apparatus for the pedestal method includes the optical laser-Doppler anemometry (LDA) package and the electronic data acquisition system. The latter comprises three channels for recording the Doppler frequency, and the pedestal amplitude as well as the validation pulse. Results of measurements performed in a dump combustor, into which kerosene droplets were injected, are presented. The principle of the PDA technique is explained and validation experiments, using latex particles, are reported. Finally the two methods are compared

  19. Methods for obtaining true particle size distributions from cross section measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lord, Kristina Alyse [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    Sectioning methods are frequently used to measure grain sizes in materials. These methods do not provide accurate grain sizes for two reasons. First, the sizes of features observed on random sections are always smaller than the true sizes of solid spherical shaped objects, as noted by Wicksell [1]. This is the case because the section very rarely passes through the center of solid spherical shaped objects randomly dispersed throughout a material. The sizes of features observed on random sections are inversely related to the distance of the center of the solid object from the section [1]. Second, on a plane section through the solid material, larger sized features are more frequently observed than smaller ones due to the larger probability for a section to come into contact with the larger sized portion of the spheres than the smaller sized portion. As a result, it is necessary to find a method that takes into account these reasons for inaccurate particle size measurements, while providing a correction factor for accurately determining true particle size measurements. I present a method for deducing true grain size distributions from those determined from specimen cross sections, either by measurement of equivalent grain diameters or linear intercepts.

  20. Computed Tomographic Measurement of Splenic Size in

    International Nuclear Information System (INIS)

    Sung, Nak Kwan; Woo, Seong Ku; Ko, Young Tae; Kim, Soon Young

    2010-01-01

    Authors analyzed 72 cases of abdominal computed tomography of Korean adults who didn't have any medical reasons to believe the spleen was abnormal. The following criteria were measured with multiple transverse scanning of the entire length of spleen (height, breadth, thickness) relationship with fixed midline structure, the spine (the shortest distance from midline to medial edge of spleen, the longest distance from anterior margin of vertebral body to anterior tip of spleen). The results were as follows: 1. The average size in adult was 8.0±1.5cm in height, 8.6±1.2cm in breadth and 3.4±0.6cm in thickness; in adult female, 7.8±1.1cm, 8.4±1.0cm and 3.4±0.6cm, respectively; total average, 7.9±1.3cm, 8.5±1.1cm and 3.4±0.6cm, respectively. No remarkable difference was noted between both sexes and age groups. 2. The shortest distance from midline to medial edge of spleen was 4.1±1.1cm in male, 3.6±1.0cm in female and total average of 3.9±1.1cm. There was remarkable difference between both sexes (P<0.005) but not between age groups. 3. The longest distance from anterior margin of vertebral body to anterior adge of spleen was 2.3±1.7cm in male, 2.0±1.4cm in female and total average of 2.2±1.6cm. No remarkable difference was seen between both sexes and age groups.

  1. Measuring the size of an earthquake

    Science.gov (United States)

    Spence, W.; Sipkin, S.A.; Choy, G.L.

    1989-01-01

    Earthquakes range broadly in size. A rock-burst in an Idaho silver mine may involve the fracture of 1 meter of rock; the 1965 Rat Island earthquake in the Aleutian arc involved a 650-kilometer length of the Earth's crust. Earthquakes can be even smaller and even larger. If an earthquake is felt or causes perceptible surface damage, then its intensity of shaking can be subjectively estimated. But many large earthquakes occur in oceanic areas or at great focal depths and are either simply not felt or their felt pattern does not really indicate their true size.

  2. Reduction of Portion Size and Eating Rate Is Associated with BMI-SDS Reduction in Overweight and Obese Children and Adolescents: Results on Eating and Nutrition Behaviour from the Observational KgAS Study

    OpenAIRE

    Torbahn, Gabriel; Gellhaus, Ines; Koch, Benjamin; von Kries, Rüdiger; Obermeier, Viola; Holl, Reinhard W.; Fink, Katharina; van Egmond-Fröhlich, Andreas

    2017-01-01

    Objective: Treatment of paediatric obesity focuses on changes of nutrition and eating behaviour and physical activity. The evaluation of the patient education programme by KgAS was utilised to analyse the association of changes of portion size, eating rate and dietary habits with BMI-SDS reductions. Methods: Patients (n = 297) were examined at the beginning and at the end of treatment and after 1-year follow-up at different out-patient centres. Their parents completed questionnaires including...

  3. Beam size measurement at high radiation levels

    International Nuclear Information System (INIS)

    Decker, F.J.

    1991-05-01

    At the end of the Stanford Linear Accelerator the high energy electron and positron beams are quite small. Beam sizes below 100 μm (σ) as well as the transverse distribution, especially tails, have to be determined. Fluorescent screens observed by TV cameras provide a quick two-dimensional picture, which can be analyzed by digitization. For running the SLAC Linear Collider (SLC) with low backgrounds at the interaction point, collimators are installed at the end of the linac. This causes a high radiation level so that the nearby cameras die within two weeks and so-called ''radiation hard'' cameras within two months. Therefore an optical system has been built, which guides a 5 mm wide picture with a resolution of about 30 μm over a distance of 12 m to an accessible region. The overall resolution is limited by the screen thickness, optical diffraction and the line resolution of the camera. Vibration, chromatic effects or air fluctuations play a much less important role. The pictures are colored to get fast information about the beam current, size and tails. Beside the emittance, more information about the tail size and betatron phase is obtained by using four screens. This will help to develop tail compensation schemes to decrease the emittance growth in the linac at high currents. 4 refs., 2 figs

  4. Looking for Off-Fault Deformation and Measuring Strain Accumulation During the Past 70 years on a Portion of the Locked San Andreas Fault

    Science.gov (United States)

    Vadman, M.; Bemis, S. P.

    2017-12-01

    Even at high tectonic rates, detection of possible off-fault plastic/aseismic deformation and variability in far-field strain accumulation requires high spatial resolution data and likely decades of measurements. Due to the influence that variability in interseismic deformation could have on the timing, size, and location of future earthquakes and the calculation of modern geodetic estimates of strain, we attempt to use historical aerial photographs to constrain deformation through time across a locked fault. Modern photo-based 3D reconstruction techniques facilitate the creation of dense point clouds from historical aerial photograph collections. We use these tools to generate a time series of high-resolution point clouds that span 10-20 km across the Carrizo Plain segment of the San Andreas fault. We chose this location due to the high tectonic rates along the San Andreas fault and lack of vegetation, which may obscure tectonic signals. We use ground control points collected with differential GPS to establish scale and georeference the aerial photograph-derived point clouds. With a locked fault assumption, point clouds can be co-registered (to one another and/or the 1.7 km wide B4 airborne lidar dataset) along the fault trace to calculate relative displacements away from the fault. We use CloudCompare to compute 3D surface displacements, which reflect the interseismic strain accumulation that occurred in the time interval between photo collections. As expected, we do not observe clear surface displacements along the primary fault trace in our comparisons of the B4 lidar data against the aerial photograph-derived point clouds. However, there may be small scale variations within the lidar swath area that represent near-fault plastic deformation. With large-scale historical photographs available for the Carrizo Plain extending back to at least the 1940s, we can potentially sample nearly half the interseismic period since the last major earthquake on this portion of

  5. Measuring bacterial cells size with AFM

    Directory of Open Access Journals (Sweden)

    Denise Osiro

    2012-03-01

    Full Text Available Atomic Force Microscopy (AFM can be used to obtain high-resolution topographical images of bacteria revealing surface details and cell integrity. During scanning however, the interactions between the AFM probe and the membrane results in distortion of the images. Such distortions or artifacts are the result of geometrical effects related to bacterial cell height, specimen curvature and the AFM probe geometry. The most common artifact in imaging is surface broadening, what can lead to errors in bacterial sizing. Several methods of correction have been proposed to compensate for these artifacts and in this study we describe a simple geometric model for the interaction between the tip (a pyramidal shaped AFM probe and the bacterium (Escherichia coli JM-109 strain to minimize the enlarging effect. Approaches to bacteria immobilization and examples of AFM images analysis are also described.

  6. Ultrasonic fetal size measurements in Brisbane, Australia

    International Nuclear Information System (INIS)

    Schluter, P.J.; Pritchard, G.; Gill, M.A.

    2004-01-01

    The purpose of this paper was to construct population-specific charts of fetal biometry for 11-41 weeks gestation in relation to known gestational age from a large population of normal Australian pregnancies when examination is performed to a standard protocol by experienced operators. All consenting eligible women attending a large Brisbane clinic between January 1993 and April 2003 were recruited. Menstrual history was taken prior to examination. Measurements were performed to a standard protocol. Prospective assessment was made about the association between gestational age from the last menstrual period and biometry. Exclusion principles were applied. Statistical analyses were performed using polynomial regression models and thorough diagnostic checks were undertaken. Included within the study were separate scans for 20 555 pregnancies from 17 660 women. Equations, means and 95th reference intervals were derived and reported for the following sonographic measurements: biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL). Population-specific regression equations for BPD, HC, AC and FL have been proposed for Australian pregnancies. Once validated by others, we believe they will warrant consideration for adoption by the Australasian Society for Ultrasound in Medicine. Copyright (2004) Blackwell Publishing Asia Pty Ltd

  7. Hall measurements and grain-size effects in polycrystalline silicon

    International Nuclear Information System (INIS)

    Ghosh, A.K.; Rose, A.; Maruska, H.P.; Eustace, D.J.; Feng, T.

    1980-01-01

    The effects of grain size on Hall measurements in polycrystalline silicon are analyzed and interpreted, with some modifications, using the model proposed by Bube. This modified model predicts that the measured effective Hall voltage is composed of components originating from the bulk and space-charge regions. For materials with large grain sizes, the carrier concentration is independent of the intergrain boundary barrier, whereas the mobility is dependent on it. However, for small grains, both the carrier density and mobility depend on the barrier. These predictions are consistent with experimental results of mm-size Wacker and μm-size neutron-transmutation-doped polycrystalline silicon

  8. Electron Beam Size Measurements in a Cooling Solenoid

    CERN Document Server

    Kroc, Thomas K; Burov, Alexey; Seletsky, Sergey; Shemyakin, Alexander V

    2005-01-01

    The Fermilab Electron Cooling Project requires a straight trajectory and constant beam size to provide effective cooling of the antiprotons in the Recycler. A measurement system was developed using movable appertures and steering bumps to measure the beam size in a 20 m long, nearly continuous, solenoid. This paper discusses the required beam parameters, the implimentation of the measurement system and results for our application.

  9. Recent activity of international comparison for nanoparticle size measurement

    Science.gov (United States)

    Takahashi, Kayori; Takahata, Keiji; Misumi, Ichiko; Sugawara, Kentaro; Gonda, Satoshi; Ehara, Kensei

    2014-08-01

    Nanoparticle sizing is the most fundamental measurement for producing nanomaterials, evaluation of nanostructure, and the risk assessment of nanomaterials for human health. Dynamic light scattering (DLS) is widely used as a useful and convenient technique for determining nanoparticle size in liquid; however, the precision of this technique has been unclear. Some international comparisons are now in progress to verify the measurement accuracy of nanoparticle sizing, as a typical example of Asia Pacific Metrology Programme Supplementary Comparison. In this study, we evaluated the precision of DLS technique for nanoparticle sizing and estimated the uncertainty of the DLS data for polystyrene latex suspensions. The extrapolations of apparent diffusion coefficients to infinite dilution and to lower angles yielded more precise values than those obtained at one angle and one concentration. The extrapolated particle size measured by DLS was compared to the size determined by differential mobility analyzer (DMA), atomic force microscopy (AFM), and scanning electron microscopy (SEM). Before the comparison, the intensity-averaged size measured by DLS was recalculated to the number-averaged size, and the thickness of water layer attaching on the surface of particles were added into uncertainty of particle sizing by DLS. After the recalculation, the consistent values of mean particle diameter were obtained between those by DLS and by DMA, AFM, and SEM within the estimated uncertainties.

  10. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  11. Multimodal Dispersion of Nanoparticles: A Comprehensive Evaluation of Size Distribution with 9 Size Measurement Methods.

    Science.gov (United States)

    Varenne, Fanny; Makky, Ali; Gaucher-Delmas, Mireille; Violleau, Frédéric; Vauthier, Christine

    2016-05-01

    Evaluation of particle size distribution (PSD) of multimodal dispersion of nanoparticles is a difficult task due to inherent limitations of size measurement methods. The present work reports the evaluation of PSD of a dispersion of poly(isobutylcyanoacrylate) nanoparticles decorated with dextran known as multimodal and developed as nanomedecine. The nine methods used were classified as batch particle i.e. Static Light Scattering (SLS) and Dynamic Light Scattering (DLS), single particle i.e. Electron Microscopy (EM), Atomic Force Microscopy (AFM), Tunable Resistive Pulse Sensing (TRPS) and Nanoparticle Tracking Analysis (NTA) and separative particle i.e. Asymmetrical Flow Field-Flow Fractionation coupled with DLS (AsFlFFF) size measurement methods. The multimodal dispersion was identified using AFM, TRPS and NTA and results were consistent with those provided with the method based on a separation step prior to on-line size measurements. None of the light scattering batch methods could reveal the complexity of the PSD of the dispersion. Difference between PSD obtained from all size measurement methods tested suggested that study of the PSD of multimodal dispersion required to analyze samples by at least one of the single size particle measurement method or a method that uses a separation step prior PSD measurement.

  12. Measuring Compartment Size and Gas Solubility in Marine Mammals

    Science.gov (United States)

    2015-09-30

    bends? Effect of diving behaviour and physiology on modelled gas exchange for three species: Ziphius cavirostris, Mesoplodon densirostris and Hyperoodon...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Measuring Compartment Size and Gas Solubility in Marine...is to develop methods to estimate marine mamal tissue compartment sizes, and tissue gas solubility. We aim to improve the data available for the

  13. Kidney size in infants and children assessed by area measurement

    International Nuclear Information System (INIS)

    Jorulf, H.; Nordmark, J.; Jonsson, A.

    1978-01-01

    A method for assessment of the kidney size in infants and children is described based on measurement of the renal parenchymal area determined planimetrically, using for reference the height of the column of the upper three lumbar vertebrae or the body weight. The kidney size is expressed in standard deviation in the appropriate nomograms. (Auth.)

  14. Grain size measurements by ultrasonic Rayleigh surface waves

    International Nuclear Information System (INIS)

    Palanichamy, P.; Jayakumar, T.

    1996-01-01

    The use of Rayleigh surface waves to determine average grain size nondestructively in an austenitic stainless steel AISI type 316 stainless is discussed. Two commercial type 4MHz frequency surface wave transducers, one as transmitter and the other as receiver were employed for the measurement of surface wave amplitudes. Relative amplitudes of the Rayleigh surface waves were correlated with the metallographically obtained grain sizes. Results indicate that surface/sub-surface average grain sizes of AISI type 316 austenitic stainless steel can be estimated with a confidence level of more than 80% in the grain size range 30-170 μm. (author)

  15. R2 effect-size measures for mediation analysis

    Science.gov (United States)

    Fairchild, Amanda J.; MacKinnon, David P.; Taborga, Marcia P.; Taylor, Aaron B.

    2010-01-01

    R2 effect-size measures are presented to assess variance accounted for in mediation models. The measures offer a means to evaluate both component paths and the overall mediated effect in mediation models. Statistical simulation results indicate acceptable bias across varying parameter and sample-size combinations. The measures are applied to a real-world example using data from a team-based health promotion program to improve the nutrition and exercise habits of firefighters. SAS and SPSS computer code are also provided for researchers to compute the measures in their own data. PMID:19363189

  16. R2 effect-size measures for mediation analysis.

    Science.gov (United States)

    Fairchild, Amanda J; Mackinnon, David P; Taborga, Marcia P; Taylor, Aaron B

    2009-05-01

    R(2) effect-size measures are presented to assess variance accounted for in mediation models. The measures offer a means to evaluate both component paths and the overall mediated effect in mediation models. Statistical simulation results indicate acceptable bias across varying parameter and sample-size combinations. The measures are applied to a real-world example using data from a team-based health promotion program to improve the nutrition and exercise habits of firefighters. SAS and SPSS computer code are also provided for researchers to compute the measures in their own data.

  17. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  18. Song repertoire size correlates with measures of body size in Eurasian blackbirds

    DEFF Research Database (Denmark)

    Hesler, Nana; Mundry, Roger; Sacher, Thomas

    2012-01-01

    In most oscine bird species males possess a repertoire of different song patterns. The size of these repertoires is assumed to serve as an honest signal of male quality. The Eurasian blackbird’s (Turdus merula) song contains a large repertoire of different element types with a flexible song...... organisation. Here we investigated whether repertoire size in Eurasian blackbirds correlates with measures of body size, namely length of wing, 8th primary, beak and tarsus. So far, very few studies have investigated species with large repertoires and a flexible song organisation in this context. We found...... positive correlations, meaning that larger males had larger repertoires. Larger males may have better fighting abilities and, thus, advantages in territorial defence. Larger structural body size may also reflect better conditions during early development. Therefore, under the assumption that body size...

  19. Causality in Statistical Power: Isomorphic Properties of Measurement, Research Design, Effect Size, and Sample Size

    Directory of Open Access Journals (Sweden)

    R. Eric Heidel

    2016-01-01

    Full Text Available Statistical power is the ability to detect a significant effect, given that the effect actually exists in a population. Like most statistical concepts, statistical power tends to induce cognitive dissonance in hepatology researchers. However, planning for statistical power by an a priori sample size calculation is of paramount importance when designing a research study. There are five specific empirical components that make up an a priori sample size calculation: the scale of measurement of the outcome, the research design, the magnitude of the effect size, the variance of the effect size, and the sample size. A framework grounded in the phenomenon of isomorphism, or interdependencies amongst different constructs with similar forms, will be presented to understand the isomorphic effects of decisions made on each of the five aforementioned components of statistical power.

  20. Size distribution measurements and chemical analysis of aerosol components

    Energy Technology Data Exchange (ETDEWEB)

    Pakkanen, T.A.

    1995-12-31

    The principal aims of this work were to improve the existing methods for size distribution measurements and to draw conclusions about atmospheric and in-stack aerosol chemistry and physics by utilizing size distributions of various aerosol components measured. A sample dissolution with dilute nitric acid in an ultrasonic bath and subsequent graphite furnace atomic absorption spectrometric analysis was found to result in low blank values and good recoveries for several elements in atmospheric fine particle size fractions below 2 {mu}m of equivalent aerodynamic particle diameter (EAD). Furthermore, it turned out that a substantial amount of analyses associated with insoluble material could be recovered since suspensions were formed. The size distribution measurements of in-stack combustion aerosols indicated two modal size distributions for most components measured. The existence of the fine particle mode suggests that a substantial fraction of such elements with two modal size distributions may vaporize and nucleate during the combustion process. In southern Norway, size distributions of atmospheric aerosol components usually exhibited one or two fine particle modes and one or two coarse particle modes. Atmospheric relative humidity values higher than 80% resulted in significant increase of the mass median diameters of the droplet mode. Important local and/or regional sources of As, Br, I, K, Mn, Pb, Sb, Si and Zn were found to exist in southern Norway. The existence of these sources was reflected in the corresponding size distributions determined, and was utilized in the development of a source identification method based on size distribution data. On the Finnish south coast, atmospheric coarse particle nitrate was found to be formed mostly through an atmospheric reaction of nitric acid with existing coarse particle sea salt but reactions and/or adsorption of nitric acid with soil derived particles also occurred. Chloride was depleted when acidic species reacted

  1. Particle size distribution measurements of radionuclides from Chernobyl

    International Nuclear Information System (INIS)

    Georgi, B.; Tschiersch, J.

    1988-01-01

    Characteristics of the size distribution of the Chernobyl aerosol have been measured at four locations along the trajectory of the cloud. Changes in time and differences between 131 I and the other isotopes are explained by aerosol physical processes. The relevance of the measurements for dose calculations are discussed

  2. Portable diffusion battery. It's application to measuring aerosol size characteristics

    International Nuclear Information System (INIS)

    Sinclair, D.

    1972-01-01

    A miniature portable cluster-tube diffusion battery for measurement of the size and size distribution of submicron aerosols (1-100 nm) is described. A series of commercially available Collimated Holes Structures are mounted in sleeves with O-rings so that aerosol penetration can be measured at a number of outlets along the series. The CHS are stainless-steel discs of several different diameters and thicknesses, containing a large number of nearly circular holes. The actual length of the apparatus is about 2 ft but the equivalent length is 3.25 mi. Calculated curves of penetration versus particle size are used to evaluate size distribution and show that the equivalent size frequently reported from one measurement with a rectangular diffusion battery is practically meaningless. The value depends as much on the characteristics and mode of the operation of the diffusion battery as on the aerosol; the longer the battery and the lower the air flow, the greater the equivalent size will appear to be. Graphical plots of the cumulative size distribution of room aerosol and silver aerosol are illustrated for large battery and miniature battery measurements and appear to be in close agreement. Measurements on radon daughters in uranium mines with the miniature batteries show activity median diameters from 0.1 to 0.17 micron, with standard deviations from 2 to 4. Two similar measurements made in the laboratory on room air tagged with about 50 pCi/l radon daughters show activity median diameters of 0.15 and 0.17 micron, with geometric standard deviations of 2.2 and 2.6, respectively

  3. Associations of acoustically measured tongue/jaw movements and portion of time speaking with negative symptom severity in patients with schizophrenia in Italy and the United States.

    Science.gov (United States)

    Bernardini, Francesco; Lunden, Anya; Covington, Michael; Broussard, Beth; Halpern, Brooke; Alolayan, Yazeed; Crisafio, Anthony; Pauselli, Luca; Balducci, Pierfrancesco M; Capulong, Leslie; Attademo, Luigi; Lucarini, Emanuela; Salierno, Gianfranco; Natalicchi, Luca; Quartesan, Roberto; Compton, Michael T

    2016-05-30

    This is the first cross-language study of the effect of schizophrenia on speech as measured by analyzing phonetic parameters with sound spectrography. We hypothesized that reduced variability in pitch and formants would be correlated with negative symptom severity in two samples of patients with schizophrenia, one from Italy, and one from the United States. Audio recordings of spontaneous speech were available from 40 patients. From each speech sample, a file of F0 (pitch) and formant values (F1 and F2, resonance bands indicating the moment-by-moment shape of the oral cavity), and the portion of the recording in which there was speaking ("fraction voiced," FV), was created. Correlations between variability in the phonetic indices and negative symptom severity were tested and further examined using regression analyses. Meaningful negative correlations between Scale for the Assessment of Negative Symptoms (SANS) total score and standard deviation (SD) of F2, as well as variability in pitch (SD F0) were observed in the Italian sample. We also found meaningful associations of SANS affective flattening and SANS alogia with SD F0, and of SANS avolition/apathy and SD F2 in the Italian sample. In both samples, FV was meaningfully correlated with SANS total score, avolition/apathy, and anhedonia/asociality. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. How big is a food portion? A pilot study in Australian families.

    Science.gov (United States)

    Collins, Clare E; Bucher, Tamara; Taylor, Aimee; Pezdirc, Kristine; Lucas, Hannah; Watson, Jane; Rollo, Megan; Duncanson, Kerith; Hutchesson, Melinda J; Burrows, Tracy

    2015-08-01

    It is not known whether individuals can accurately estimate the portion size of foods usually consumed relative to standard serving sizes in national food selection guides. The aim of the present cross-sectional pilot study was to quantify what adults and children deem a typical portion for a variety of foods and compare these with the serving sizes specified in the Australian Guide to Healthy Eating (AGHE). Adults and children were independently asked to serve out their typical portion of 10 common foods (rice, pasta, breakfast cereal, chocolate, confectionary, ice cream, meat, vegetables, soft drink and milk). They were also asked to serve what they perceived a small, medium and large portion of each food to be. Each portion was weighed and recorded by an assessor and compared with the standard AGHE serving sizes. Twenty-one individuals (nine mothers, one father, 11 children) participated in the study. There was a large degree of variability in portion sizes measured out by both parents and children, with means exceeding the standard AGHE serving size for all items, except for soft drink and milk, where mean portion sizes were less than the AGHE serving size. The greatest mean overestimations were for pasta (155%; mean 116 g; range 94-139 g) and chocolate (151%; mean 38 g; range 25-50 g), each of which represented approximately 1.5 standard AGHE servings. The findings of the present study indicate that there is variability between parents' and children's estimation of typical portion sizes compared with national recommendations. SO WHAT? Dietary interventions to improve individuals' dietary patterns should target education regarding portion size.

  5. Accuracy of the photogrametric measuring system for large size elements

    Directory of Open Access Journals (Sweden)

    M. Grzelka

    2011-04-01

    Full Text Available The aim of this paper is to present methods of estimating and guidelines for verifying the accuracy of optical photogrammetric measuringsystems, using for measurement of large size elements. Measuring systems applied to measure workpieces of a large size which oftenreach more than 10000mm require use of appropriate standards. Those standards provided by the manufacturer of photogrammetricsystems are certified and are inspected annually. To make sure that these systems work properly there was developed a special standardVDI / VDE 2634, "Optical 3D measuring systems. Imaging systems with point - by - point probing. " According to recommendationsdescribed in this standard research on accuracy of photogrametric measuring system was conducted using K class gauge blocks dedicatedto calibrate and test accuracy of classic CMMs. The paper presents results of research of estimation the actual error of indication for sizemeasurement MPEE for photogrammetric coordinate measuring system TRITOP.

  6. How to measure breast cancer tumoral size at MR imaging?

    International Nuclear Information System (INIS)

    Thomassin-Naggara, I.; Siles, Pascale; Trop, I.; Chopier, J.; Darai, E.; Bazot, M.

    2013-01-01

    Objective: To compare the accuracy of different MR sequences to measure tumor size. Methods: Eighty-six women (mean age: 53 years (30–78)) who underwent preoperative MRI for breast cancer were included. Maximal diameters of the index tumor (IT) and of the whole extent of the tumor (WET) were measured on T2-weighted (T2W) sequences, on dynamic contrast-enhanced (DCE) T1-weighted (T1W) sequences and on Maximal Intensity Projection (MIP) reconstructions. Agreements with pathological size were evaluated using concordance correlation coefficient (k). Results: Median pathological size of IT was 20 mm (13–25 mm, interquartile range). Median pathological size of the WET was 29 mm (16–50 mm, interquartile range). Measurement of IT showed a good concordance with pathological size, with best results using T2W (k = 0.690) compared to MIP (k = 0.667), early-subtracted DCE frame (k = 0.630) and early-native DCE frame (k = 0.588). IT was visible on T2W in 83.7% and accurately measured within 5 mm in 69.9%. Measurement of WET was superior using early-subtracted DCE frame (k = 0.642) compared to late-native frame (k = 0.635), early-native frame (k = 0.631), late-subtracted frame (k = 0.620) and MIP (k = 0.565). However, even using early-subtracted frame, WET was accurately measured within 5 mm only 39.3%. Conclusion: If visible, IT size is best measured on T2W with a good accuracy (69%) whereas WET is best estimated on early-subtracted DCE frame. However, when adjacent additional sites exist around IT, suspected surrounding disease components need to be proved by pathological analysis

  7. X-ray tube focal spot sizes: comprehensive studies of their measurement and effect of measured size in angiography

    International Nuclear Information System (INIS)

    Doi, K.; Loo, L.N.; Chan, H.P.

    1982-01-01

    Thirty-two focal spot sizes of four x-ray tubes were measured by the pinhole, star pattern, slit, and root-mean-square (RMS) methods under various exposure conditions. The modulation transfer functions (MTFs) and line spread functions (LSFs) were also determined. The star pattern focal spot sizes agreed with the effective sizes calculated from the frequencies at the first minimum of the MTF within 0.04 mm for large focal spots and within 0.01 mm for small focal spots. The focal spot size determined by the slit method was approximately equal to the width of the LSF at the cutoff level of 0.15 +/- 0.06 of the peak value. The RMS method provided the best correlation between the measured focal spot sizes and the corresponding image distributions of blood vessels. The pinhole and slit methods tended to overestimate the focal spot size, but the star pattern method tended to underestimate it. For approximately 90% of the focal spots, the average of the star and slit (or pinhole) focal spot sizes agreed with the RMS focal spot size within +/- 0.1 mm

  8. A computerized system for handling renal size measurements from urograms

    International Nuclear Information System (INIS)

    Claesson, I.; Jacobsson, B.F.; Riha, M.

    1987-01-01

    The size of a kidney, as measured on an urogram, is a sensitive indicator of renal damage in a child with urinary tract infection, and renal surface area correlates well with glomerular filtration rate. Sequential measurements can be invaluable in evaluating the efficacy of a regimen of treatment. A system utilizing a personal microcomputer has been developed to facilitate the measuring procedure and the handling and analysis of data. (orig.)

  9. Measurement of inclusion size by laser ablation ICP mass spectrometry

    International Nuclear Information System (INIS)

    Karasev, Andrey V.; Suito, Hideaki

    2004-01-01

    By using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), the measurement of particle size has been made for one component oxide (Al 2 O 3 and MgO) and multicomponent oxide (12CaO·7Al 2 O 3 and CaO-Al 2 O 3 -MgO) located on surface of iron or glass sample. The method of particle size estimation by LA-ICP-MS has been developed coupled with a new method of making samples with particles. The size calibration lines for Al 2 O 3 , MgO and CaO particles have been obtained. The results of particle size measurement by LA-ICP-MS are compared with those by SEM and single-particle optical sensing (SPOS) methods. It was confirmed that LA-ICP-MS has the perspective to be used for the quick measurement of inclusion composition and size in metal and other materials. The size frequency distributions of Al 2 O 3 particles measured by LA-ICP-MS in iron samples with particles agree reasonably well with those by SEM and SPOS in the range of particle diameter from 2 to 20 μm. The size of Al 2 O 3 , MgO and complex oxide (12CaO·7Al 2 O 3 and CaO-Al 2 O 3 -MgO) particles measured by LA-ICP-MS is in good agreement with that by SEM in the range of particle diameter from 10 to 40 μm. (author)

  10. Pore size determination from charged particle energy loss measurement

    International Nuclear Information System (INIS)

    Brady, F.P.; Armitage, B.H.

    1977-01-01

    A new method aimed at measuring porosity and mean pore size in materials has been developed at Harwell. The energy width or variance of a transmitted or backscattered charged particle beam is measured and related to the mean pore size via the assumption that the variance in total path length in the porous material is given by (Δx 2 )=na 2 , where n is the mean number of pores and a the mean pore size. It is shown on the basis of a general and rigorous theory of total path length distribution that this approximation can give rise to large errors in the mean pore size determination particularly in the case of large porosities (epsilon>0.5). In practice it is found that it is not easy to utilize fully the general theory because accurate measurements of the first four moments are required to determine the means and variances of the pore and inter-pore length distributions. Several models for these distributions are proposed. When these are incorporated in the general theory the determinations of mean pore size from experimental measurements on powder samples are in good agreement with values determined by other methods. (Auth.)

  11. Penetration portion shielding structure

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Narita, Hitoshi; Handa, Hiroyuki; Takeuchi, Jun; Tozuka, Fumio.

    1994-01-01

    Openings of a plurality of shieldings for penetration members are aligned to each other, and penetration members are inserted from the openings. Then, the openings of the plurality of shielding members are slightly displaced with each other to make the penetration portions into a helical configuration, so that leakage of radiation is reduced. Upon removal of the members, reverse operation is conducted. When a flowable shielding material is used, the penetration portions are constituted with two plates having previously formed openings and pipes for connecting the openings with each other and a vessel covering the entire of them. After passing the penetration members such as a cable, the relative position of the two plates is changed by twisting, to form a helical configuration which reduces radiation leakage. Since they are bent into the helical configuration, shielding performance is extremely improved compared with a case that radiation leakage is caused from an opening of a straight pipe. In addition, since they can be returned to straight pipes, attachment, detachment and maintenance can be conducted easily. (N.H.)

  12. Measurement of size distribution for 220Rn progeny attached aerosols

    International Nuclear Information System (INIS)

    Zhang Lei; Guo Qiuju; Zhuo Weihai

    2008-01-01

    The size distribution of radioactive aerosols is a very important factor for evaluating the inner exposure dose contributed by radon and thoron progeny in environments. In order to measure the size distribution of thoron progeny attached radioactive aerosols, a device was developed using wire screens. The count median diameter (CMD) and the geometric standard deviation (GSD) of attached radioactive aerosols were calculated by collecting ThB and using CR-39 as detector. Field measurement results at Yangjiang City in Guangdong Province show that the CMDs distribute between 30 and 130 nm, and the GSDs are between 1.9 and 3.3. It also shows that the more humid country, the smaller CMDs, and the ventilation has great influence on the size distribution of aerosols. The CMDs of adobe house are smaller than that of the concrete houses. (authors)

  13. Photometric imaging in particle size measurement and surface visualization.

    Science.gov (United States)

    Sandler, Niklas

    2011-09-30

    The aim of this paper is to give an insight into photometric particle sizing approaches, which differ from the typical particle size measurement of dispersed particles. These approaches can often be advantageous especially for samples that are moist or cohesive, when dispersion of particles is difficult or sometimes impossible. The main focus of this paper is in the use of photometric stereo imaging. The technique allows the reconstruction of three-dimensional images of objects using multiple light sources in illumination. The use of photometric techniques is demonstrated in at-line measurement of granules and on-line measurement during granulation and dry milling. Also, surface visualization and roughness measurements are briefly discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Laser triangulation method for measuring the size of parking claw

    Science.gov (United States)

    Liu, Bo; Zhang, Ming; Pang, Ying

    2017-10-01

    With the development of science and technology and the maturity of measurement technology, the 3D profile measurement technology has been developed rapidly. Three dimensional measurement technology is widely used in mold manufacturing, industrial inspection, automatic processing and manufacturing, etc. There are many kinds of situations in scientific research and industrial production. It is necessary to transform the original mechanical parts into the 3D data model on the computer quickly and accurately. At present, many methods have been developed to measure the contour size, laser triangulation is one of the most widely used methods.

  15. Functional Size Measurement applied to UML-based user requirements

    NARCIS (Netherlands)

    van den Berg, Klaas; Dekkers, Ton; Oudshoorn, Rogier; Dekkers, T.

    There is a growing interest in applying standardized methods for Functional Size Measurement (FSM) to Functional User Requirements (FUR) based on models in the Unified Modelling Language (UML). No consensus exists on this issue. We analyzed the demands that FSM places on FURs. We propose a

  16. Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction

    Science.gov (United States)

    Fritz, Bradley K.; Hoffmann, W. Clint

    2016-01-01

    When making an application of any crop protection material such as an herbicide or pesticide, the applicator uses a variety of skills and information to make an application so that the material reaches the target site (i.e., plant). Information critical in this process is the droplet size that a particular spray nozzle, spray pressure, and spray solution combination generates, as droplet size greatly influences product efficacy and how the spray moves through the environment. Researchers and product manufacturers commonly use laser diffraction equipment to measure the spray droplet size in laboratory wind tunnels. The work presented here describes methods used in making spray droplet size measurements with laser diffraction equipment for both ground and aerial application scenarios that can be used to ensure inter- and intra-laboratory precision while minimizing sampling bias associated with laser diffraction systems. Maintaining critical measurement distances and concurrent airflow throughout the testing process is key to this precision. Real time data quality analysis is also critical to preventing excess variation in the data or extraneous inclusion of erroneous data. Some limitations of this method include atypical spray nozzles, spray solutions or application conditions that result in spray streams that do not fully atomize within the measurement distances discussed. Successful adaption of this method can provide a highly efficient method for evaluation of the performance of agrochemical spray application nozzles under a variety of operational settings. Also discussed are potential experimental design considerations that can be included to enhance functionality of the data collected. PMID:27684589

  17. Method for measuring the size distribution of airborne rhinovirus

    International Nuclear Information System (INIS)

    Russell, M.L.; Goth-Goldstein, R.; Apte, M.G.; Fisk, W.J.

    2002-01-01

    About 50% of viral-induced respiratory illnesses are caused by the human rhinovirus (HRV). Measurements of the concentrations and sizes of bioaerosols are critical for research on building characteristics, aerosol transport, and mitigation measures. We developed a quantitative reverse transcription-coupled polymerase chain reaction (RT-PCR) assay for HRV and verified that this assay detects HRV in nasal lavage samples. A quantitation standard was used to determine a detection limit of 5 fg of HRV RNA with a linear range over 1000-fold. To measure the size distribution of HRV aerosols, volunteers with a head cold spent two hours in a ventilated research chamber. Airborne particles from the chamber were collected using an Andersen Six-Stage Cascade Impactor. Each stage of the impactor was analyzed by quantitative RT-PCR for HRV. For the first two volunteers with confirmed HRV infection, but with mild symptoms, we were unable to detect HRV on any stage of the impactor

  18. Method for measuring the size distribution of airborne rhinovirus

    Energy Technology Data Exchange (ETDEWEB)

    Russell, M.L.; Goth-Goldstein, R.; Apte, M.G.; Fisk, W.J.

    2002-01-01

    About 50% of viral-induced respiratory illnesses are caused by the human rhinovirus (HRV). Measurements of the concentrations and sizes of bioaerosols are critical for research on building characteristics, aerosol transport, and mitigation measures. We developed a quantitative reverse transcription-coupled polymerase chain reaction (RT-PCR) assay for HRV and verified that this assay detects HRV in nasal lavage samples. A quantitation standard was used to determine a detection limit of 5 fg of HRV RNA with a linear range over 1000-fold. To measure the size distribution of HRV aerosols, volunteers with a head cold spent two hours in a ventilated research chamber. Airborne particles from the chamber were collected using an Andersen Six-Stage Cascade Impactor. Each stage of the impactor was analyzed by quantitative RT-PCR for HRV. For the first two volunteers with confirmed HRV infection, but with mild symptoms, we were unable to detect HRV on any stage of the impactor.

  19. Reproducibility of airway luminal size in asthma measured by HRCT.

    Science.gov (United States)

    Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A

    2017-10-01

    Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack

  20. Radioactive Aerosol Size Distribution Measured in Nuclear Workplaces

    International Nuclear Information System (INIS)

    Kravchik, T.; Oved, S.; German, U.

    2002-01-01

    Inhalation is the main route for internal exposure of workers to radioactive aerosols in the nuclear industry.Aerosol's size distribution and in particular its activity median aerodynamic diameter (AMAD)is important for determining the fractional deposition of inhaled particles in the respiratory tract and the resulting doses. Respiratory tract models have been published by the International Commission on radiological Protection (ICRP).The former model has recommended a default AMAD of 1 micron for the calculation of dose coefficients for workers in the nuclear industry [1].The recent model recommends a 5 microns default diameter for occupational exposure which is considered to be more representative of workplace aerosols [2]. Several researches on radioactive aerosol's size distribution in nuclear workplaces has supported this recommendation [3,4].This paper presents the results of radioactive aerosols size distribution measurements taken at several workplaces of the uranium production process

  1. Vertebral scale system to measure canine heart size in radiographs

    International Nuclear Information System (INIS)

    Buchanan, J.W.; Bucheler, J.

    1995-01-01

    A method for measuring canine heart size in radiographs was developed on the basis that there is a good correlation between heart size and body length regardless of the conformation of the thorax. The lengths of the long and short axes of the heart of 100 clinically normal dogs were determined with calipers, and the dimensions were scaled against the length of vertebrae dorsal to the heart beginning with T4. The sum of the long and short axes of the heart expressed as vertebral heart size was 9.7 +/- 0.5 vertebrae. The differences between dogs with a wide or deep thorax, males and females, and right or left lateral recumbency were not significant. The caudal vena cava was 0.75 vertebrae +/- 0.13 in comparison to the length of the vertebra over the tracheal bifurcation

  2. Measurement of neuron soma size by fluorescent Nissl stain

    OpenAIRE

    sprotocols

    2015-01-01

    Authors: James Cronk, Noel Derecki & Jonathan Kipnis ### Abstract This protocol describes how to measure neuron soma size by fluorescent Nissl stain. Mice are sacrificed, and fixed by PFA perfusion. Brains are removed, and further PFA fixed, followed by sucrose cryoprotection. They are then snap frozen, sliced by cryostat, and stained with fluorescent Nissl as floating sections. Confocal microscopy is used to take images of neurons, and a computer graphics tablet is used to calculate ...

  3. Integral image rendering procedure for aberration correction and size measurement.

    Science.gov (United States)

    Sommer, Holger; Ihrig, Andreas; Ebenau, Melanie; Flühs, Dirk; Spaan, Bernhard; Eichmann, Marion

    2014-05-20

    The challenge in rendering integral images is to use as much information preserved by the light field as possible to reconstruct a captured scene in a three-dimensional way. We propose a rendering algorithm based on the projection of rays through a detailed simulation of the optical path, considering all the physical properties and locations of the optical elements. The rendered images contain information about the correct size of imaged objects without the need to calibrate the imaging device. Additionally, aberrations of the optical system may be corrected, depending on the setup of the integral imaging device. We show simulation data that illustrates the aberration correction ability and experimental data from our plenoptic camera, which illustrates the capability of our proposed algorithm to measure size and distance. We believe this rendering procedure will be useful in the future for three-dimensional ophthalmic imaging of the human retina.

  4. Single-size thermometric measurements on a size distribution of neutral fullerenes.

    Science.gov (United States)

    Cauchy, C; Bakker, J M; Huismans, Y; Rouzée, A; Redlich, B; van der Meer, A F G; Bordas, C; Vrakking, M J J; Lépine, F

    2013-05-10

    We present measurements of the velocity distribution of electrons emitted from mass-selected neutral fullerenes, performed at the intracavity free electron laser FELICE. We make use of mass-specific vibrational resonances in the infrared domain to selectively heat up one out of a distribution of several fullerene species. Efficient energy redistribution leads to decay via thermionic emission. Time-resolved electron kinetic energy distributions measured give information on the decay rate of the selected fullerene. This method is generally applicable to all neutral species that exhibit thermionic emission and provides a unique tool to study the stability of mass-selected neutral clusters and molecules that are only available as part of a size distribution.

  5. Measurements from preterm infants to guide face mask size.

    Science.gov (United States)

    O'Shea, Joyce E; Thio, Marta; Owen, Louise S; Wong, Connie; Dawson, Jennifer A; Davis, Peter G

    2016-07-01

    International guidelines recommend that an appropriately sized face mask for providing positive pressure ventilation should cover the mouth and nose but not the eyes and should not overlap the chin. This study aimed to measure the dimensions of preterm infants' faces and compare these with the size of the most commonly available face masks (external diameter 50 mm) and the smallest masks available (external diameters 35 and 42 mm). Infants 24-33 weeks' postmenstrual age (PMA) were photographed in a standardised manner. Images were analysed using ImageJ software (National Institute of Health, USA) to calculate the distance from the nasofrontal groove to the mental protuberance. This facial measurement corresponds to the external diameter of an optimally fitting mask. A cohort of 107 infants between 24 and 33 weeks' gestational age, including at least 10 infants per week of gestation, was photographed within 72 h after birth and weekly until 33 weeks' PMA. 347 photographs were analysed. Infants of 24, 26, 28, 30 and 32 weeks' PMA had mean (SD) facial measurements of 32 (2), 36 (3), 38 (4), 41 (2) and 43 (4) mm, respectively. There were no significant differences when examined by gender or when small for gestational age infants were excluded. The smallest size of some brands of mask is too large for many preterm infants. Masks of 35 mm diameter are suitable for infants Masks of 42 mm diameter are suitable for infants 27-33 weeks' PMA or 750-2500 g. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. The size of thyroid gland measured by scan

    International Nuclear Information System (INIS)

    Choe, K. O.; Choe, Y. K.; Park, C. Y.; Choi, B. S.

    1973-01-01

    Normal size of thyroid gland in Korean male and female were aimed to study through color scanning using radioactive materials. The measurement of the size of thyroid gland is necessary not only for standardization of Korean subjects but also to the dose determination of radioactive iodine treatment and evaluation of thyroid disease. There had been no available data in regarding Korean euthyroid size in literature. In 119 subjects from the age of 19 years to 60 tears, who have normal thyroid function and no history of any thyroid disorder, the length, the width and the area of thyroid gland were measured in scan images. The weight of thyroid gland was calculated by Allen-Goodwin's formula. The thyroid scan was obtained by Picker Color Magna-Scanner, in 24 hours after ingestion of 50μCi sodium iodide 1-131. Results; In males, 16 subjects among 119 cases, the mean values were as following: length-5.1 cm, width-2.5 cm, area-9.1 cm 2 , weight-14.7 gr in right lobe, length-4.7 cm, width-2.3 cm, area-7.6 cm 2 , weight-11.1 gr in left lobe, total area-16.7 cm 2 , and total weight-25.8 gr. In females, 103 subjects among 119 cases, the mean values were as following: length-5.1 cm, width-2.4 cm, area-9.4 cm 2 , weight-15.2 gr in the right lobe, length-4.6 cm, width-2.2 cm, area-7.9 cm 2 , weight-11.6 gr in left lobe, total area-17.3 cm 2 , total weight-26.8 gr. The right lobe was larger in the above mean values of size than the left: 11% longer in length, 8% wider in width, 18% broader in area and 30% heavier in weight in mean values. The difference of sizes between two lobes was statistically significant. There was no significant difference comparison with English written literature

  7. Spall Strength Measurements of Concrete for Varying Aggregate Sizes

    International Nuclear Information System (INIS)

    Chhabildas, Lalit C.; Kipp, Marlin E.; Reinhart, William D.; Wilson, Leonard T.

    1999-01-01

    Controlled impact experiments have been performed to determine the spall strength of four different concrete compositions. The four concrete compositions are identified as, 'SAC-5, CSPC', (''3/4'') large, and (''3/8'') small, Aggregate. They differ primarily in aggregate size but with average densities varying by less than five percent. Wave profiles from sixteen experiments, with shock amplitudes of 0.07 to 0.55 GPa, concentrate primarily within the elastic regime. Free-surface particle velocity measurements indicate consistent pullback signals in the release profiles, denoting average span strength of approximately 40 MPa. It is the purpose of this paper to present spall measurements under uniaxial strain loading. Notwithstanding considerable wave structure that is a unique characteristic to the heterogeneous nature of the scaled concrete, the spall amplitudes appear reproducible and consistent over the pressure range reported in this study

  8. Particle size distributions of radioactive aerosols measured in workplaces

    International Nuclear Information System (INIS)

    Dorrian, M.-D.; Bailey, M.R.

    1995-01-01

    A survey of published values of Activity Median Aerodynamic Diameter (AMAD) measured in working environments was conducted to assist in the selection of a realistic default AMAD for occupational exposures. Results were compiled from 52 publications covering a wide variety of industries and workplaces. Reported values of AMAD from all studies ranged from 0.12 μm to 25 μm, and most were well fitted by a log-normal distribution with a median value of 4.4 μm. This supports the choice of a 5 μm default AMAD, as a realistic rounded value for occupational exposures, by the ICRP Task Group on Human Respiratory Tract Models for Radiological Protection and its acceptance by ICRP. Both the nuclear power and nuclear fuel handling industries gave median values of approximately 4 μm. Uranium mills gave a median value of 6.8 μm with AMADs frequently greater than 10 μm. High temperature and arc saw cutting operations generated submicron particles and occasionally, biomodal log-normal particle size distributions. It is concluded that in view of the wide range of AMADs found in the surveyed literature, greater emphasis should be placed on air sampling to characterise aerosol particle size distributions for individual work practices, especially as doses estimated with the new 5 μm default AMAD will not always be conservative. (author)

  9. Determination of particle size distributions from acoustic wave propagation measurements

    International Nuclear Information System (INIS)

    Spelt, P.D.; Norato, M.A.; Sangani, A.S.; Tavlarides, L.L.

    1999-01-01

    The wave equations for the interior and exterior of the particles are ensemble averaged and combined with an analysis by Allegra and Hawley [J. Acoust. Soc. Am. 51, 1545 (1972)] for the interaction of a single particle with the incident wave to determine the phase speed and attenuation of sound waves propagating through dilute slurries. The theory is shown to compare very well with the measured attenuation. The inverse problem, i.e., the problem of determining the particle size distribution given the attenuation as a function of frequency, is examined using regularization techniques that have been successful for bubbly liquids. It is shown that, unlike the bubbly liquids, the success of solving the inverse problem is limited since it depends strongly on the nature of particles and the frequency range used in inverse calculations. copyright 1999 American Institute of Physics

  10. Enhancement of blurred image portions

    NARCIS (Netherlands)

    2008-01-01

    This invention relates to a method for image enhancement, comprising a first step ( 41 ) of distinguishing blurred and non-blurred image portions of an input image, and a second step ( 42 ) of enhancing at least one of said blurred image portions of said input image to produce an output image. Said

  11. Resonant tunneling measurements of size-induced strain relaxation

    Science.gov (United States)

    Akyuz, Can Deniz

    Lattice mismatch strain available in such semiconductor heterostructures as Si/SiGe or GaAs/AlGaAs can be employed to alter the electronic and optoelectronic properties of semiconductor structures and devices. When deep submicron structures are fabricated from strained material, strained layers relax by sidewall expansion giving rise to size- and geometry-dependent strain gradients throughout the structure. This thesis describes a novel experimental technique to probe the size-induced strain relaxation by studying the tunneling current characteristics of strained p-type Si/SiGe resonant tunneling diodes. Our current-voltage measurements on submicron strained p-Si/SiGe double- and triple-barrier resonant tunneling structures as a function of device diameter, D, provide experimental access to both the average strain relaxation (which leads to relative shifts in the tunneling current peak positions) and strain gradients (which give rise to a fine structure in the current peaks due to inhomogeneous strain-induced lateral quantization). We find that strain relaxation is significant, with a large fraction of the strain energy relaxed on average in D ≤ 0.25 m m devices. Further, the in-plane potentials that arise from inhomogeneous strain gradients are large. In the D ˜ 0.2 m m devices, the corresponding lateral potentials are approximately parabolic exceeding ˜ 25 meV near the perimeter. These potentials create discrete hole states in double-barrier structures (single well), and coupled hole states in triple-barrier structures (two wells). Our results are in excellent agreement with finite-element strain calculations in which the strained layers are permitted to relax to a state of minimum energy by sidewall expansion. Size-induced strain relaxation will undoubtedly become a serious technological issue once strained devices are scaled down to the deep submicron regime. Interestingly, our calculations predict and our measurements are consistent with the appearance of

  12. Understanding the shape of the Earth and measuring its size

    Science.gov (United States)

    Baltatzis, Evangelos; Galanaki, Angeliki

    2016-04-01

    Most elementary students have problems and misconceptions regarding the shape of the Earth. Teachers often contribute to this confusion telling the students that the Earth is almost spherical, but not explaining to them, how the Earth can be spherical while it appears. It would be helpful for students to understand how humanity came with the idea of the spherical Earth (to be precise the Earth is ellipsoid). Historically, most cultures describe the Earth as flat. That changes with the ancient Greek culture. We don't know exactly how the Greeks first understood the spherical shape of the Earth, but some Greek philosophers give some arguments why the Earth must be a sphere. We can discuss these arguments and observations with the students. First, if someone travels in the south, he can see the southern constellations rise higher above the horizon. We can give students pictures of the night sky in southern regions and compare them with observations of ''their'' night sky. Second, in the lunar eclipse we can see the round shadow of the Earth. Third, whenever a ship is on the horizon, his low part is invisible . This is known as "hull-down". Moreover, the low part of mountains is invisible from the sea, due to the curvature of the Earth. It is always better to make these observations in real life but it can also be done via videos and pictures. The realization of the spherical shape of the Earth was sine qua non for the first good measurement of its size. In the second part of the project, following the ancient mathematician Eratosthenes's steps, students can measure the size of the Earth, , find pleasure in doing experimental work and realize how important mathematics is in everyday life. Two sticks, situated a long distance away from each other, can give us approximately the circumference , the radius and the diameter of the Earth. Eratosthenes used geometry combined to the knowledge of ancient Greek culture that the Earth is spherical (360°). He knew the distance

  13. Portion size tells who I am, food type tells who you are: Specific functions of amount and type of food in same- and opposite-sex dyadic eating contexts.

    Science.gov (United States)

    Cavazza, Nicoletta; Guidetti, Margherita; Butera, Fabrizio

    2017-05-01

    Previous research has shown that women eating small portions of food (vs. eating big portions) are perceived as more feminine, whereas men eating large portions are perceived as more masculine. The specific type of food items have also been shown to carry connotations for gender stereotyping. In addition, matching the co-eater's food quantity is also a means to ingratiate him or her. Thus, a potential motivational conflict between gender identity expression and ingratiation arises when people eat in opposite-sex dyads. Scholars have, thus far, focused their attention on one of these two dimensions at a time, and rarely in relation to the co-eaters' sex. The present study investigated, through a restaurant scenario, the way in which women and men, when asked to imagine having lunch in dyads, combine food choice and quantity regulation as a function of the co-eater's sex. Results showed that participants use the quantity dimension to communicate gender identity, and the food type dimension to ingratiate the co-eater's preferences by matching her/his presumed choice, following gender-based stereotypes about food. In opposite-sex dyads, dishes that incorporate the two dimensions were chosen above the expected frequency. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Measuring the Size of a Small, Frost World

    Science.gov (United States)

    2006-01-01

    Observing a very rare occultation of a star by Pluto's satellite Charon from three different sites, including Paranal, home of the VLT, astronomers were able to determine with great accuracy the radius and density of the satellite to the farthest planet. The density, 1.71 that of water, is indicative of an icy body with about slightly more than half of rocks. The observations also put strong constraints on the existence of an atmosphere around Charon. ESO PR Photo 02a/06 ESO PR Photo 02a/06 Artist's Impression of the Pluto-Charon system Since its discovery in 1978, Charon and Pluto have appeared to form a double planet, rather than a planet-satellite couple. Actually, Charon is about twice as small as Pluto in size, and about eight times less massive. However, there have been considerable discussions concerning the precise radii of Pluto and Charon, as well as about the presence of a tenuous atmosphere around Charon. In August 2004, Australian amateur astronomer Dave Herald predicted that the 15-magnitude star UCAC2 26257135 should be occulted by Charon on 11 July 2005. The occultation would be observable from some parts of South America, including Cerro Paranal, in the northern Atacama Desert, the location of ESO's Very Large Telescope (VLT). Stellar occultations have proved to be powerful tools to both measure sizes - at km-level accuracy, i.e. a factor ten better than what is feasible with other techniques - and detect very tenuous atmosphere - at microbar levels or less. Unfortunately, in the case of Charon, such occultations are extremely rare, owing to the very small angular diameter of the satellite on the sky: 55 milli-arcsec, i.e. the size of a one Euro coin observed from 100 km away! This explains why only one occultation by Charon was ever observed before 2005, namely on 7 April 1980 by Alistair Walker, from the South Africa Astronomical Observatory. Similarly, only in 1985, 1988 and 2002 could astronomers observe stellar occultations by Pluto. Quite

  15. Sonographic measurement of thymic size in healthy Korean neonates

    International Nuclear Information System (INIS)

    Seo, Hyun Joo; Yoon, Dae Young; Han, Dae Hee; Han, Sang Wook; Kim, Ho Chul; Kim, Young Mook; Choi, Chul Soon; Bae, Sang Hoon

    2001-01-01

    To assess the variation in thymic size in healthy Korean neonates by sonography and to study the possible correlation to clinical variables. This study was made of 112 healthy Korean neonates (94 full-term and 18 preterm), at less than a week of age. The transverse diameter of the thymus was measured in a transverse scan and the largest sagittal area was assessed in a longitudinal scan. The thymic index was defined as the product of these two values. Then, this index was compared to clinical variables, such as sex, delivery method (spontaneous delivery vs cesarian section), body weight, height, body surface area, head circumference, chest circumference, gestational age, and maternal age in both full-term and preterm groups. The thymic index was 9.6 ± 3.1 (range 3.1-20.2) in full-term and 4.2 ± 2.4 (range 0.9-9.9) in preterm neonates, respectively. The thymic index was positively correlated to the body weight (R=0.550 in full-term, R=0.669 in preterm) and body surface area (R=0.540 in full-term, R=0.674 in preterm) in both full-term and preterm groups (p<0.01). There was no statistically significant correlation to sex, delivery method, height, head circumference, chest circumference, maternal age or gestational age. The thymic index in Healthy Korean neonates as measured by sonography is significantly correlated to the body weight and body surface area of the neonate.

  16. Measuring micron size beams in the SLC final focus

    International Nuclear Information System (INIS)

    McCormick, D.; Ross, M.; DeBarger, S.

    1994-10-01

    A pair of high resolution wire scanners have been built and installed in the SLC final focus. The final focus optics uses a set of de-magnifying telescopes, and an ideal location for a beam size monitor is at one of the magnified image points of the interaction point. The image point chosen for these scanners is in the middle of a large bend magnet. The design beam spots here are about 2 microns in the vertical and 20 microns in the horizontal plane. The scanners presented a number of design challenges. In this paper we discuss the mechanical design of the scanner, and fabrication techniques of its ceramic wire support card which holds many 4 and 7 um carbon wires. Accurate motion of the wire during a scan is critical. In this paper we describe tests of stepper motors, gear combinations, and radiation hardened encoders needed to produce the required motion with a step resolution of 80 nanometers. Also presented here are the results of scattered radiation detector placement studies carried out to optimize the signal from the 4 micron wires. Finally, we present measurements from the scanner

  17. Measuring the size of an airport's catchment area

    NARCIS (Netherlands)

    Lieshout, R.

    2012-01-01

    Although much empirical research exists on the factors that drive passenger airport choice, not much is known about the related topic of airport catchment area size. This paper presents a novel methodology to assess the size of airport catchment areas and the airport’s market shares therein using a

  18. Vertebral scale system to measure heart size in thoracic radiographs ...

    African Journals Online (AJOL)

    In veterinary diagnostic radiology, determination of heart size is necessary in the assessment of patients with clinical signs of cardiac anomaly. In this study, heart sizes were compared with lengths of mid-thoracic vertebrae in 12 clinically normal West African Dwarf Goats (WADGs) (8 females, 4 males). The aim of the ...

  19. Association between different phases of menstrual cycle and body image measures of perceived size, ideal size, and body dissatisfaction.

    Science.gov (United States)

    Teixeira, André Luiz S; Dias, Marcelo Ricardo C; Damasceno, Vinícius O; Lamounier, Joel A; Gardner, Rick M

    2013-12-01

    The association between phases of the menstrual cycle and body image was investigated. 44 university women (M age = 23.3 yr., SD = 4.7) judged their perceived and ideal body size, and body dissatisfaction was calculated at each phase of the menstrual cycle, including premenstrual, menstrual, and intermenstrual. Participants selected one of nine figural drawings ranging from very thin to obese that represented their perceived size and ideal size. Body dissatisfaction was measured as the absolute difference between scores on perceived and ideal figural drawings. During each menstrual phase, anthropometric measures of weight, height, body mass index, circumference of waist and abdomen, and body composition were taken. There were no significant differences in any anthropometric measures between the three menstrual cycle phases. Perceived body size and body dissatisfaction were significantly different between menstrual phases, with the largest perceived body size and highest body dissatisfaction occurring during the menstrual phase. Ideal body size did not differ between menstrual phases, although participants desired a significantly smaller ideal size as compared to the perceived size.

  20. Measuring agglomerate size distribution and dependence of localized surface plasmon resonance absorbance on gold nanoparticle agglomerate size using analytical ultracentrifugation.

    Science.gov (United States)

    Zook, Justin M; Rastogi, Vinayak; Maccuspie, Robert I; Keene, Athena M; Fagan, Jeffrey

    2011-10-25

    Agglomeration of nanoparticles during measurements in relevant biological and environmental media is a frequent problem in nanomaterial property characterization. The primary problem is typically that any changes to the size distribution can dramatically affect the potential nanotoxicity or other size-determined properties, such as the absorbance signal in a biosensor measurement. Herein we demonstrate analytical ultracentrifugation (AUC) as a powerful method for measuring two critical characteristics of nanoparticle (NP) agglomerates in situ in biological media: the NP agglomerate size distribution, and the localized surface plasmon resonance (LSPR) absorbance spectrum of precise sizes of gold NP agglomerates. To characterize the size distribution, we present a theoretical framework for calculating the hydrodynamic diameter distribution of NP agglomerates from their sedimentation coefficient distribution. We measure sedimentation rates for monomers, dimers, and trimers, as well as for larger agglomerates with up to 600 NPs. The AUC size distributions were found generally to be broader than the size distributions estimated from dynamic light scattering and diffusion-limited colloidal aggregation theory, an alternative bulk measurement method that relies on several assumptions. In addition, the measured sedimentation coefficients can be used in nanotoxicity studies to predict how quickly the agglomerates sediment out of solution under normal gravitational forces, such as in the environment. We also calculate the absorbance spectra for monomer, dimer, trimer, and larger gold NP agglomerates up to 600 NPs, to enable a better understanding of LSPR biosensors. Finally, we validate a new method that uses these spectra to deconvolute the net absorbance spectrum of an unknown bulk sample and approximate the proportions of monomers, dimers, and trimers in a polydisperse sample of small agglomerates, so that every sample does not need to be measured by AUC. These results

  1. Measurement of penile size in healthy Nigerian newborns using ...

    African Journals Online (AJOL)

    newborn male infants. J Pediatr 1975; 86:395–398. 6 Flatau E, Josefsberg Z, Reisner SH, Bialik O, Iaron Z. Letter: penile size in the newborn infant. J Pediatr 1975; 87:663–664. 7 Boas M, Boisen KA, Virtanen HE, Kaleva M, Suomi AM, Schmidt IM, et al. Postnatal penile length and growth rate correlate to serum testosterone.

  2. Measurement of joint space width and erosion size

    NARCIS (Netherlands)

    Sharp, JI; van der Heijde, D; Angwin, J; Duryea, J; Moens, HJB; Jacobs, JWG; Maillefert, JF; Strand, CV

    2005-01-01

    Measurement of radiographic abnormalities in metric units has been reported by several investigators during the last 15 years. Measurement of joint space in large joints has been employed in a few trials to evaluate therapy in osteoarthritis. Measurement of joint space width in small joints has been

  3. An Effect Size Measure for Raju's Differential Functioning for Items and Tests

    Science.gov (United States)

    Wright, Keith D.; Oshima, T. C.

    2015-01-01

    This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…

  4. Transverse micro-erosion meter measurements; determining minimum sample size

    Science.gov (United States)

    Trenhaile, Alan S.; Lakhan, V. Chris

    2011-11-01

    Two transverse micro-erosion meter (TMEM) stations were installed in each of four rock slabs, a slate/shale, basalt, phyllite/schist, and sandstone. One station was sprayed each day with fresh water and the other with a synthetic sea water solution (salt water). To record changes in surface elevation (usually downwearing but with some swelling), 100 measurements (the pilot survey), the maximum for the TMEM used in this study, were made at each station in February 2010, and then at two-monthly intervals until February 2011. The data were normalized using Box-Cox transformations and analyzed to determine the minimum number of measurements needed to obtain station means that fall within a range of confidence limits of the population means, and the means of the pilot survey. The effect on the confidence limits of reducing an already small number of measurements (say 15 or less) is much greater than that of reducing a much larger number of measurements (say more than 50) by the same amount. There was a tendency for the number of measurements, for the same confidence limits, to increase with the rate of downwearing, although it was also dependent on whether the surface was treated with fresh or salt water. About 10 measurements often provided fairly reasonable estimates of rates of surface change but with fairly high percentage confidence intervals in slowly eroding rocks; however, many more measurements were generally needed to derive means within 10% of the population means. The results were tabulated and graphed to provide an indication of the approximate number of measurements required for given confidence limits, and the confidence limits that might be attained for a given number of measurements.

  5. Single-Size Thermometric Measurements on a Size Distribution of Neutral Fullerenes

    NARCIS (Netherlands)

    Cauchy, C.; Bakker, J. M.; Huismans, Y.; Rouzee, A.; Redlich, B.; van der Meer, A. F. G.; Bordas, C.; Vrakking, M. J. J.; Lepine, F.

    2013-01-01

    We present measurements of the velocity distribution of electrons emitted from mass-selected neutral fullerenes, performed at the intracavity free electron laser FELICE. We make use of mass-specific vibrational resonances in the infrared domain to selectively heat up one out of a distribution of

  6. Radiation Pressure Measurements on Micron-Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P. D.; Spann, J. F.; Witherow, W. K.; West, E. A.; Gallagher, D. L.; Adrian, M. L.; Fishman, G. J.; Tankosic, D.; LeClair, A.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

  7. Radiation Pressure Measurements on Micron Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P.D.; Spann, J. F.; Tankosic, D.; Witherow, W. K.; LeClair, A.; West, E.; Sheldon, R.; Gallagher, D. L.; Adrian, M. L.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

  8. Pixel size and pitch measurements of liquid crystal spatial light ...

    Indian Academy of Sciences (India)

    However, some departure from square pixel shape and pitch may result due to the manufacturing constraints and environmental changes like temperature or mechanical stresses. To our knowledge, we did not come across any detailed studies to accurately measure these variations (if any) in the available literature. We find ...

  9. Uncertainties of size measurements in electron microscopy characterization of nanomaterials in foods

    DEFF Research Database (Denmark)

    Dudkiewicz, Agnieszka; Boxall, Alistair B. A.; Chaudhry, Qasim

    2015-01-01

    Electron microscopy is a recognized standard tool for nanomaterial characterization, and recommended by the European Food Safety Authority for the size measurement of nanomaterials in food. Despite this, little data have been published assessing the reliability of the method, especially for size...... measurement of nanomaterials characterized by a broad size distribution and/or added to food matrices. This study is a thorough investigation of the measurement uncertainty when applying electron microscopy for size measurement of engineered nanomaterials in foods. Our results show that the number of measured...

  10. A Nanometer Aerosol Size Analyzer (nASA) for Rapid Measurement of High-concentration Size Distributions

    International Nuclear Information System (INIS)

    Han, H.-S.; Chen, D.-R.; Pui, David Y.H.; Anderson, Bruce E.

    2000-01-01

    We have developed a fast-response nanometer aerosol size analyzer (nASA) that is capable of scanning 30 size channels between 3 and 100 nm in a total time of 3 s. The analyzer includes a bipolar charger (Po 210 ), an extended-length nanometer differential mobility analyzer (Nano-DMA), and an electrometer (TSI 3068). This combination of components provides particle size spectra at a scan rate of 0.1 s per channel free of uncertainties caused by response-time-induced smearing. The nASA thus offers a fast response for aerosol size distribution measurements in high-concentration conditions and also eliminates the need for applying a de-smearing algorithm to resulting data. In addition, because of its thermodynamically stable means of particle detection, the nASA is useful for applications requiring measurements over a broad range of sample pressures and temperatures. Indeed, experimental transfer functions determined for the extended-length Nano-DMA using the tandem differential mobility analyzer (TDMA) technique indicate the nASA provides good size resolution at pressures as low as 200 Torr. Also, as was demonstrated in tests to characterize the soot emissions from the J85-GE engine of a T-38 aircraft, the broad dynamic concentration range of the nASA makes it particularly suitable for studies of combustion or particle formation processes. Further details of the nASA performance as well as results from calibrations, laboratory tests and field applications are presented below

  11. Effect Size Measures for Differential Item Functioning in a Multidimensional IRT Model

    Science.gov (United States)

    Suh, Youngsuk

    2016-01-01

    This study adapted an effect size measure used for studying differential item functioning (DIF) in unidimensional tests and extended the measure to multidimensional tests. Two effect size measures were considered in a multidimensional item response theory model: signed weighted P-difference and unsigned weighted P-difference. The performance of…

  12. Porcionamento dos principais alimentos e preparações consumidos por adultos e idosos residentes no município de São Paulo Portion sizes of the main foods and preparations consumed by adults and elderly living in the city of São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Jackeline Venancio Carlos

    2008-08-01

    Full Text Available OBJETIVO: Identificar o tamanho das porções dos alimentos e das preparações mais consumidas ou que mais contribuem com o valor energético total da dieta de adultos e idosos. MÉTODOS: Realizou-se inquérito domiciliar de base populacional em 2003, com amostra representativa de 1 477 indivíduos acima de 20 anos residentes no município de São Paulo. O consumo alimentar foi verificado pelo recordatório de 24 horas, digitado no programa Nutrition Data System. Os alimentos e as preparações selecionados para averiguação da porção foram os consumidos por, no mínimo, 10% da população de estudo ou que contribuíram com até 80% do valor energético total. As porções médias, obtidas pelo percentil 50, foram comparadas segundo sexo e estado nutricional, por meio do teste de Kruskal Wallis. RESULTADOS: Arroz e feijão foram os alimentos mais consumidos e que mais contribuíram para o valor energético da dieta. Os homens consumiram maior porção destes alimentos, quando são comparados às mulheres. Observou-se que a porção de leite está abaixo do estipulado pelo Guia Alimentar Brasileiro, porém a maior diferença encontrada foi em relação à alface e ao tomate. Verificou-se que indivíduos com excesso de peso consomem maiores porções de peito de frango. CONCLUSÃO: O tamanho das porções de alguns alimentos é maior entre homens, porém, na prática, não há como diferenciar, em medidas caseiras, valores tão próximos como os encontrados na maioria dos alimentos. As porções dos principais alimentos dos grupos de verduras e legumes e leite e derivados são menores que o proposto pelo Guia Alimentar.OBJECTIVE: Identify the portion sizes of the most consumed foods and preparations or those that contribute most to the total energy of the diet of adults and seniors. METHODS: A population-based household survey with a representative sample of 1 477 individuals older than 20 years living in the city of São Paulo was done in

  13. Measuring Economic Freedom: Better Without Size of Government.

    Science.gov (United States)

    Ott, Jan

    2018-01-01

    The Heritage Foundation and the Fraser Institute measure economic freedom in nations using indices with ten and five indicators respectively. Eight of the Heritage indicators and four of the Fraser-indicators are about specific types of institutional quality, like rule of law, the protection of property, and the provision of sound money. More of these is considered to denote more economic freedom. Both indices also involve indicators of 'big government', or levels of government activities. More of that is seen to denote less economic freedom. Yet, levels of government spending, consumption, and transfers and subsidies appear to correlate positively with the other indicators related to institutional quality, while this correlation is close to zero for the level of taxation as a percentage of GDP. Using government spending, consumption transfers and subsidies as positive indicators is no alternative, because these levels stand for very different government activities, liberal or less liberal. This means that levels of government activities can better be left out as negative or positive indicators. Thus shortened variants of the indices create a better convergent validity in the measurement of economic freedom, and create higher correlations between economic freedom and alternative types of freedom, and between economic freedom and happiness. The higher correlations indicate a better predictive validity, since they are predictable in view of the findings of previous research and theoretical considerations about the relations between types of freedom, and between freedom and happiness.

  14. Fairness-Based Tasks for Assessing Children’s Perceptions of Food Quantities and Associations with Portion Selection

    Directory of Open Access Journals (Sweden)

    Aurore Ferrage

    2018-04-01

    Full Text Available It is critical to develop ecologically valid experimental methods to assess consumers’ food-related behaviors. Ad libitum approaches are often used but may not be appropriate for studies with children or with products that are not typically consumed until the individual feels full. The current study presents novel methods to assess children’s size perception and portion preference for gummy candies. In the first study, 62 children (30 boys, 32 girls aged 6 to 9 years completed two matching tasks: one using pictures on a computer screen, and a similar task where the products were physically manipulated. Results of the two matching tasks were correlated, demonstrating that a computer-based approach could be used to predict the factors influencing children’s perception of food amount: the number, size, and shape of pieces. In the second study, a portioning measure was developed to investigate whether the factors identified in the matching tasks were confirmed in a task that more closely represented portion selection in the real world. The effects observed in the matching tasks could not be replicated in the portioning task. The size of each item had no significant impact on the portion selection, suggesting that it may be possible to reduce the size of pieces in snacks where multiple pieces are typically consumed without negatively impacting perceived quantity in children, thus offering a promising strategy to nudge children toward choosing smaller portions.

  15. A simple algorithm for measuring particle size distributions on an uneven background from TEM images

    DEFF Research Database (Denmark)

    Gontard, Lionel Cervera; Ozkaya, Dogan; Dunin-Borkowski, Rafal E.

    2011-01-01

    Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence of a...... application to images of heterogeneous catalysts is presented.......Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence...

  16. "What time is my next meal?" delay-discounting individuals choose smaller portions under conditions of uncertainty.

    Science.gov (United States)

    Zimmerman, Annie R; Ferriday, Danielle; Davies, Sarah R; Martin, Ashley A; Rogers, Peter J; Mason, Alice; Brunstrom, Jeffrey M

    2017-09-01

    'Dietary' delay discounting is typically framed as a trade-off between immediate rewards and long-term health concerns. Our contention is that prospective thinking also occurs over shorter periods, and is engaged to select portion sizes based on the interval between meals (inter-meal interval; IMI). We sought to assess the extent to which the length of an IMI influences portion-size selection. We predicted that delay discounters would show 'IMI insensitivity' (relative lack of concern about hunger or fullness between meals). In particular, we were interested in participants' sensitivity to an uncertain IMI. We hypothesized that when meal times were uncertain, delay discounters would be less responsive and select smaller portion sizes. Participants (N = 90) selected portion sizes for lunch. In different trials, they were told to expect dinner at 5pm, 9pm, and either 5pm or 9pm (uncertain IMI). Individual differences in future-orientation were measured using a monetary delay-discounting task. Participants chose larger portions when the IMI was longer (p relationship between BMI and smaller portion selection in uncertainty (p < 0.05). This is the first study to report an association between delay discounting and IMI insensitivity. We reason that delay discounters selected smaller portions because they were less sensitive to the uncertain IMI, and overlooked concerns about potential future hunger. These findings are important because they illustrate that differences in discounting are expressed in short-term portion-size decisions and suggest that IMI insensitivity increases when meal timings are uncertain. Further research is needed to confirm whether these findings generalise to other populations. Copyright © 2017. Published by Elsevier Ltd.

  17. PlantSize Offers an Affordable, Non-destructive Method to Measure Plant Size and Color in Vitro

    Directory of Open Access Journals (Sweden)

    Dóra Faragó

    2018-02-01

    Full Text Available Plant size, shape and color are important parameters of plants, which have traditionally been measured by destructive and time-consuming methods. Non-destructive image analysis is an increasingly popular technology to characterize plant development in time. High throughput automatic phenotyping platforms can simultaneously analyze multiple morphological and physiological parameters of hundreds or thousands of plants. Such platforms are, however, expensive and are not affordable for many laboratories. Moreover, determination of basic parameters is sufficient for most studies. Here we describe a non-invasive method, which simultaneously measures basic morphological and physiological parameters of in vitro cultured plants. Changes of plant size, shape and color is monitored by repeated photography with a commercial digital camera using neutral white background. Images are analyzed with the MatLab-based computer application PlantSize, which simultaneously calculates several parameters including rosette size, convex area, convex ratio, chlorophyll and anthocyanin contents of all plants identified on the image. Numerical data are exported in MS Excel-compatible format. Subsequent data processing provides information on growth rates, chlorophyll and anthocyanin contents. Proof-of-concept validation of the imaging technology was demonstrated by revealing small but significant differences between wild type and transgenic Arabidopsis plants overexpressing the HSFA4A transcription factor or the hsfa4a knockout mutant, subjected to different stress conditions. While HSFA4A overexpression was associated with better growth, higher chlorophyll and lower anthocyanin content in saline conditions, the knockout hsfa4a mutant showed hypersensitivity to various stresses. Morphological differences were revealed by comparing rosette size, shape and color of wild type plants with phytochrome B (phyB-9 mutant. While the technology was developed with Arabidopsis plants

  18. Small angle neutron scattering measurements of magnetic cluster sizes in magnetic recorging disks

    CERN Document Server

    Toney, M

    2003-01-01

    We describe Small Angle Neutron Scattering measurements of the magnetic cluster size distributions for several longitudinal magnetic recording media. We find that the average magnetic cluster size is slightly larger than the average physical grain size, that there is a broad distribution of cluster sizes, and that the cluster size is inversely correlated to the media signal-to-noise ratio. These results show that intergranular magnetic coupling in these media is small and they provide empirical data for the cluster-size distribution that can be incorporated into models of magnetic recording.

  19. Statistical properties of four effect-size measures for mediation models.

    Science.gov (United States)

    Miočević, Milica; O'Rourke, Holly P; MacKinnon, David P; Brown, Hendricks C

    2018-02-01

    This project examined the performance of classical and Bayesian estimators of four effect size measures for the indirect effect in a single-mediator model and a two-mediator model. Compared to the proportion and ratio mediation effect sizes, standardized mediation effect-size measures were relatively unbiased and efficient in the single-mediator model and the two-mediator model. Percentile and bias-corrected bootstrap interval estimates of ab/s Y , and ab(s X )/s Y in the single-mediator model outperformed interval estimates of the proportion and ratio effect sizes in terms of power, Type I error rate, coverage, imbalance, and interval width. For the two-mediator model, standardized effect-size measures were superior to the proportion and ratio effect-size measures. Furthermore, it was found that Bayesian point and interval summaries of posterior distributions of standardized effect-size measures reduced excessive relative bias for certain parameter combinations. The standardized effect-size measures are the best effect-size measures for quantifying mediated effects.

  20. Measuring Restriction Sizes Using Diffusion Weighted Magnetic Resonance Imaging: A Review

    Directory of Open Access Journals (Sweden)

    Melanie Martin

    2013-01-01

    Full Text Available This article reviews a new concept in magnetic resonance as applied to cellular and biological systems. Diffusion weighted magnetic resonance imaging can be used to infer information about restriction sizes of samples being measured. The measurements rely on the apparent diffusion coefficient changing with diffusion times as measurements move from restricted to free diffusion regimes. Pulsed gradient spin echo (PGSE measurements are limited in the ability to shorten diffusion times and thus are limited in restriction sizes which can be probed. Oscillating gradient spin echo (OGSE measurements could provide shorter diffusion times so smaller restriction sizes could be probed.

  1. Imaging and size measurement of nanoparticles in aqueous medium by use of atomic force microscopy.

    Science.gov (United States)

    Takechi-Haraya, Yuki; Goda, Yukihiro; Sakai-Kato, Kumiko

    2018-02-01

    Size control of nanoparticles in nanotechnology-based drug products is crucial for their successful development, since the in vivo pharmacokinetics of nanoparticles are size-dependent. In this study, we evaluated the use of atomic force microscopy (AFM) for imaging and size measurement of nanoparticles in aqueous medium. The height sizes of rigid polystyrene nanoparticles and soft liposomes were measured by AFM and were compared with the hydrodynamic sizes measured by dynamic light scattering (DLS). The lipid compositions of the studied liposomes were similar to those of commercial products. AFM proved to be a viable method for obtaining images of both polystyrene nanoparticles and liposomes in aqueous medium. For the polystyrene nanoparticles, the average height size observed by AFM was similar to the average number-weighted diameter obtained by DLS, indicating the usefulness of AFM for measuring the sizes of nanoparticles in aqueous medium. For the liposomes, the height sizes obtained by AFM differed depending upon the procedures of immobilizing the liposomes onto a solid substrate. In addition, the resultant average height sizes of the liposomes were smaller than those obtained by DLS. This knowledge will help the correct use of AFM as a powerful tool for imaging and size measurement of nanotechnology-based drug products for clinical use.

  2. Measurement of particle size distribution of soil and selected aggregate sizes using the hydrometer method and laser diffractometry

    Science.gov (United States)

    Guzmán, G.; Gómez, J. A.; Giráldez, J. V.

    2010-05-01

    Soil particle size distribution has been traditionally determined by the hydrometer or the sieve-pipette methods, both of them time consuming and requiring a relatively large soil sample. This might be a limitation in situations, such as for instance analysis of suspended sediment, when the sample is small. A possible alternative to these methods are the optical techniques such as laser diffractometry. However the literature indicates that the use of this technique as an alternative to traditional methods is still limited, because the difficulty in replicating the results obtained with the standard methods. In this study we present the percentages of soil grain size determined using laser diffractometry within ranges set between 0.04 - 2000 μm. A Beckman-Coulter ® LS-230 with a 750 nm laser beam and software version 3.2 in five soils, representative of southern Spain: Alameda, Benacazón, Conchuela, Lanjarón and Pedrera. In three of the studied soils (Alameda, Benacazón and Conchuela) the particle size distribution of each aggregate size class was also determined. Aggregate size classes were obtained by dry sieve analysis using a Retsch AS 200 basic ®. Two hundred grams of air dried soil were sieved during 150 s, at amplitude 2 mm, getting nine different sizes between 2000 μm and 10 μm. Analyses were performed by triplicate. The soil sample preparation was also adapted to our conditions. A small amount each soil sample (less than 1 g) was transferred to the fluid module full of running water and disaggregated by ultrasonication at energy level 4 and 80 ml of sodium hexametaphosphate solution during 580 seconds. Two replicates of each sample were performed. Each measurement was made for a 90 second reading at a pump speed of 62. After the laser diffractometry analysis, each soil and its aggregate classes were processed calibrating its own optical model fitting the optical parameters that mainly depends on the color and the shape of the analyzed particle. As a

  3. A practical and theoretical definition of very small field size for radiotherapy output factor measurements.

    Science.gov (United States)

    Charles, P H; Cranmer-Sargison, G; Thwaites, D I; Crowe, S B; Kairn, T; Knight, R T; Kenny, J; Langton, C M; Trapp, J V

    2014-04-01

    This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. According to the practical definition established in this project, field sizes ≤ 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤ 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤ 12 mm. Source occlusion also caused a large change in OPF for field sizes ≤ 8 mm. Based on the results of this study, field sizes ≤ 12 mm were considered to be theoretically very small for 6 MV beams. Extremely

  4. The measurement of activity-weighted size distributions of radon progeny: methods and laboratory intercomparison studies

    International Nuclear Information System (INIS)

    Hopke, P.K.; Strydom, R.; Ramamurthi, M.; Knutson, E.O.; Tu, K.W.; Scofield, P.; Holub, R.F.; Cheng, Y.S.; Su, Y.F.; Winklmayr, W.

    1992-01-01

    Over the past 5 y, there have been significant improvements in measurement of activity-weighted size distributions of airborne radon decay products. The modification of screen diffusion batteries to incorporate multiple screens of differing mesh number, called graded screen arrays, have permitted improved size resolution below 10 nm such that the size distributions can now be determined down to molecular sized activities (0.5 nm). In order to ascertain the utility and reliability of such systems, several intercomparison tests have been performed in a 2.4 m3 radon chamber in which particles of varying size have been produced by introducing SO2 and H2O along with the radon to the chamber. In April 1988, intercomparison studies were performed between direct measurements of the activity-weighted size distributions as measured by graded screen arrays and an indirect measurement of the distribution obtained by measuring the number size distribution with a differential mobility analyzer and multiplying by the theoretical attachment rate. Good agreement was obtained in these measurements. A second set of intercomparison studies among a number of groups with graded screen array systems was made in April 1989 with the objective of resolving spectral structure below 10 nm. Again, generally good agreement among the various groups was obtained although some differences were noted. It is thus concluded that such systems can be constructed and can be useful in making routine measurements of activity-weighted size distributions with reasonable confidence in the results obtained

  5. Measurement of the size distributions of radon progeny in indoor air

    International Nuclear Information System (INIS)

    Hopke, P.K.; Ramamurthi, M.; Li, C.S.

    1990-01-01

    A major problem in evaluating the health risk posed by airborne radon progeny in indoor atmospheres is the lack of available information on the activity-weighted size distributions that occur in the domestic environment. With an automated, semicontinuous, graded screen array system, we made a series of measurements of activity-weighted size distributions in several houses in the northeastern United States. Measurements were made in an unoccupied house, in which human aerosol-generating activities were simulated. The time evolution of the aerosol size distribution was measured in each situation. Results of these measurements are presented

  6. Simulation of the measure of the microparticle size distribution in two dimensions

    International Nuclear Information System (INIS)

    Lameiras, F.S.; Pinheiro, P.

    1987-01-01

    Different size distributions of plane figures were generated in a computer as a simply connected network. These size distributions were measured by the Saltykov method for two dimensions. The comparison between the generated and measured distributions showed that the Saltkov method tends to measure larger scattering than the real one and to move the maximum of the real distribution to larger diameters. These erros were determined by means of the ratio of the perimeter of the figures per unit area directly measured and the perimeter calculated from the size distribution obtained by using the SaltyKov method. (Author) [pt

  7. Size measurement of radioactive aerosol particles in intense radiation fields using wire screens and imaging plates

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yuichi; Tanaka, Toru; Takamiya, Koichi; Ishi, Yoshihiro; UesugI, Tomonori; Kuriyama, Yasutoshi; Sakamoto, Masaaki; Ohtsuki, Tsutomu [Kyoto University Research Reactor Institute, Osaka (Japan); Nitta, Shinnosuke [Graduate School of Engineering, Kyoto University, Kyoto (Japan); Osada, Naoyuki [Advanced Science Research Center, Okayama University, Okayama (Japan)

    2016-09-15

    Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of 11C-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. The size distribution for 11C-bearing aerosol particles was found to be ca. 70 μm in geometric mean diameter. The size was similar to that for 7Be-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

  8. What is the role of portion control in weight management?

    Science.gov (United States)

    Rolls, B J

    2014-01-01

    Systematic studies have shown that providing individuals with larger portions of foods and beverages leads to substantial increases in energy intake. The effect is sustained over weeks, supporting the possibility that large portions have a role in the development of obesity. The challenge is to find strategies to effectively manage the effects of portion size. One approach involves teaching people to select appropriate portions and to use tools that facilitate portion control. Although tools such as portion-control plates have been shown in several randomized trials to improve weight loss, limited data are available on whether education and tools lead to long-term changes in eating behavior and body weight. Another approach is to use preportioned foods (PPFs) to add structure to meals and minimize decisions about the amount of food to eat. A number of randomized controlled trials have demonstrated the efficacy of both liquid meal replacements and solid PPFs for weight loss and weight loss maintenance, but it is not known if they lead to better understanding of appropriate portions. Although portion control is important for weight management, urging people simply to ‘eat less' of all foods may not be the best approach as high-energy-dense foods disproportionately increase energy intake compared with those lower in energy density. A more effective strategy may be to encourage people to increase the proportion of foods low in energy density in their diets while limiting portions of high-energy-dense foods. If people lower the energy density of their diet, they can eat satisfying portions while managing their body weight. PMID:25033958

  9. Effects of diffraction and target finite size on coherent transition radiation spectra in bunch length measurements

    Energy Technology Data Exchange (ETDEWEB)

    Castellano, M.; Cianchi, A.; Verzilov, V.A. [Istituto Nazionale di Fisica Nucleare, Frascati, RM (Italy). Laboratori Nazionali di Frascati; Orlandi, G. [Istituto Nazionale di Fisica Nucleare, Rome (Italy)]|[Rome Univ., Tor Vergata, Rome (Italy)

    1999-07-01

    Effects of diffraction and the size of the target on TR in the context of CTR-based bunch length measurements are studied on the basis of Kirchhoff diffraction theory. Spectra of TR from the finite-size target for several schemes of measurements are calculated in the far-infrared region showing strong distortion at low frequencies. Influence of the effect on the accuracy of bunch length measurements is estimated.

  10. Eating Habits, Nutritional Status and Portion Sizes in the Elderly ...

    African Journals Online (AJOL)

    98.3%) and “Farata” (66.7%) were the most frequently consumed carbohydrate group. We also found that, for the meat category, chicken (73.3%) was preferred by most of them. 88.3% and 96.7% of the study sample population consumed fruits ...

  11. Caregivers' attitudes regarding portion size served to Head Start children

    Science.gov (United States)

    The purpose of this study was to identify caregivers' attitudes regarding amounts and types of foods served to Head Start preschoolers using qualitative methods. Researchers conducted 8 focus groups (4 African American; 4 Hispanic) with 33 African American and 29 Hispanic Head Start caregivers. Mode...

  12. Portion and Serving Sizes of Commonly Consumed Foods

    African Journals Online (AJOL)

    Dr Olaleye

    consume energy and nutrients in inadequate or excess of requirements. Inadequate ... reported inadequate dietary intakes, very little information exists on ... reasonable estimate, 50% will be used q = 1.0-p ... Whose consumption was not affected by ill health, fasting ..... metabolic syndrome in Tehranian adults. International.

  13. Determination of Optimal Portion Size for Hot Combat Rations

    Science.gov (United States)

    1986-07-12

    slices 18 058 Creamed Ground Beef 12 1 cup 12K 18c 18C 062 Pork Sausage Links 30 3 links 073 Scrambled Eggs /Ham 20 i cut 4x5 or scrambled...Gravy 20 3 slices 18 027 Stuffed Peppers 8 2 peppers NA 006 Swedish Meatballs 15 2 meatballs 12 106 Chicken/Noodles 12 1 cup 12 107 Chicken Cacciatore...1/2 cups NA 005 Lasagna 12 cut 3x4 12 016 Spaghetti/ Meatballs 8 1-1/2 cups incl 2 meatballs NA 036 Beef Swiss Steak/Gravy 14 1 slice 12 112

  14. Measuring size evolution of distant, faint galaxies in the radio regime

    Science.gov (United States)

    Lindroos, L.; Knudsen, K. K.; Stanley, F.; Muxlow, T. W. B.; Beswick, R. J.; Conway, J.; Radcliffe, J. F.; Wrigley, N.

    2018-05-01

    We measure the evolution of sizes for star-forming galaxies as seen in 1.4 GHz continuum radio for z = 0-3. The measurements are based on combined VLA+MERLIN data of the Hubble Deep Field, and using a uv-stacking algorithm combined with model fitting to estimate the average sizes of galaxies. A sample of ˜1000 star-forming galaxies is selected from optical and near-infrared catalogues, with stellar masses M⊙ ≈ 1010-1011 M⊙ and photometric redshifts 0-3. The median sizes are parametrized for stellar mass M* = 5 × 1010 M⊙ as R_e = A× {}(H(z)/H(1.5))^{α _z}. We find that the median radio sizes evolve towards larger sizes at later times with αz = -1.1 ± 0.6, and A (the median size at z ≈ 1.5) is found to be 0.26^'' ± 0.07^'' or 2.3±0.6 kpc. The measured radio sizes are typically a factor of 2 smaller than those measure in the optical, and are also smaller than the typical H α sizes in the literature. This indicates that star formation, as traced by the radio continuum, is typically concentrated towards the centre of galaxies, for the sampled redshift range. Furthermore, the discrepancy of measured sizes from different tracers of star formation, indicates the need for models of size evolution to adopt a multiwavelength approach in the measurement of the sizes star-forming regions.

  15. Three-dimensional computed tomography measurement accuracy of varying Hill-Sachs lesion size.

    Science.gov (United States)

    Ho, Anthony; Kurdziel, Michael D; Koueiter, Denise M; Wiater, J Michael

    2018-02-01

    The glenoid track concept has been proposed to correlate shoulder stability with bone loss. Accurate assessment of Hill-Sachs lesion size preoperatively may affect surgical planning and postoperative outcomes; however, no measurement method has been universally accepted. This study aimed to assess the accuracy and reliability of measuring Hill-Sachs lesion sizes using 3-dimensional (3D) computed tomography (CT). Nine polyurethane humerus bone substitutes were used to create Hill-Sachs lesions of varying sizes with a combination of lesion depth (shallow, intermediate, and deep) and width (small, medium, and large). Specimens were scanned with a clinical CT scanner for size measurements and a micro-CT scanner for measurement of true lesion size. Six evaluators repeated measurements twice in a 2-week interval. Scans were measured by use of 3D CT reconstructions for length, width, and Hill-Sachs interval and with use of 2D CT for depth. The interclass correlation coefficient evaluated interobserver and intraobserver variability and percentage error, and Student t-tests assessed measurement accuracy. Interclass correlation coefficient reliability demonstrated strong agreement for all variables measured (0.856-0.975). Percentage error between measured length and measured depth and the true measurement significantly varied with respect to both lesion depth (P = .003 and P = .005, respectively) and lesion size (P = .049 and P = .004, respectively). The 3D CT imaging is effective and reproducible in determining lesion size. Determination of Hill-Sachs interval width is also reliable when it is applied to the glenoid track concept. Measured values on 3D and 2-dimensional imaging using a conventional CT scanner may slightly underestimate true measurements. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Simultaneous velocity and particle size measurement in two phase flows by Laser Anemometry

    Science.gov (United States)

    Ungut, A.; Yule, A. J.; Taylor, D. S.; Chigier, N. A.

    1978-01-01

    A technique for particle size measurement by using Laser Doppler Anemometry is discussed. An additional gate photomultiplier has been introduced at right angles to the optical axis in order to select only those particles passing through the central region of the measurement control volume. Particle sizing measurements have been made in sprays of glass particles using the modified Laser Anemometry system. Measurements in fuel sprays are also reported and compared with the results obtained by a photographic technique. The application of the particle sizing technique to opaque particles is investigated and suitable optical arrangements are suggested. Light scattering characteristics of Laser Anemometry systems for different optical geometries are calculated to select the optimum optical arrangement for the particle sizing measurements.

  17. Confocal pore size measurement based on super-resolution image restoration.

    Science.gov (United States)

    Liu, Dali; Wang, Yun; Qiu, Lirong; Mao, Xinyue; Zhao, Weiqian

    2014-09-01

    A confocal pore size measurement based on super-resolution image restoration is proposed to obtain a fast and accurate measurement for submicrometer pore size of nuclear track-etched membranes (NTEMs). This method facilitates the online inspection of the pore size evolution during etching. Combining confocal microscopy with super-resolution image restoration significantly improves the lateral resolution of the NTEM image, yields a reasonable circle edge-setting criterion of 0.2408, and achieves precise pore edge detection. Theoretical analysis shows that the minimum measuring diameter can reach 0.19 μm, and the root mean square of the residuals is only 1.4 nm. Edge response simulation and experiment reveal that the edge response of the proposed method is better than 80 nm. The NTEM pore size measurement results obtained by the proposed method agree well with that obtained by scanning electron microscopy.

  18. FIELD COMPARISONS OF DUAL SMPS-APS SYSTEMS TO MEASURE INDOOR-OUTDOOR PARTICLE SIZE DISTRIBUTIONS

    Science.gov (United States)

    Simultaneous measurements of particle size distributions across multiple locations can provide critical information to accurately assess human exposure to particles. These data are very useful to describe indoor-outdoor particle relationships, outdoor particle penetration thro...

  19. Counter-Propagating Optical Trapping System for Size and Refractive Index Measurement of Microparticles

    National Research Council Canada - National Science Library

    Flynn, Richard A; Shao, Bing; Chachisvilis, Mirianas; Ozkan, Mihrimah; Esener, Sadik C

    2005-01-01

    We propose and demonstrate a novel approach to measure the size and refractive index of microparticles based on two beam optical trapping, where forward scattered light is detected to give information about the particle...

  20. Tumor size measured by preoperative ultrasonography and postoperative pathologic examination in papillary thyroid carcinoma: relative differences according to size, calcification and coexisting thyroiditis.

    Science.gov (United States)

    Yoon, Young Hoon; Kwon, Ki Ryun; Kwak, Seo Young; Ryu, Kyeung A; Choi, Bobae; Kim, Jin-Man; Koo, Bon Seok

    2014-05-01

    Ultrasonography (US) is a useful diagnostic modality for evaluation of the size and features of thyroid nodules. Tumor size is a key indicator of the surgical extent of thyroid cancer. We evaluated the difference in tumor sizes measured by preoperative US and postoperative pathologic examination in papillary thyroid carcinoma (PTC). We reviewed the medical records of 172 consecutive patients, who underwent thyroidectomy for PTC treatment. We compared tumor size, as measured by preoperative US, with that in postoperative specimens. And we analyzed a number of factors potentially influencing the size measurement, including cancer size, calcification and coexisting thyroiditis. The mean size of the tumor measured by preoperative US was 11.4, and 10.2 mm by postoperative pathologic examination. The mean percentage difference (US-pathology/US) of tumor sizes measured by preoperative US and postoperative pathologic examination was 9.9 ± 19.3%, which was statistically significant (p 20.0 mm) and the presence of calcification or coexisting thyroiditis on the tumor size discrepancy between the two measurements was analyzed, the mean percentage differences according to tumor size (9.1 vs. 11.2% vs. 9.8%, p = 0.842), calcification (9.2 vs. 10.2%, p = 0.756) and coexisting thyroiditis (17.6 vs. 9.5%, p = 0.223) did not show statistical significance. Tumor sizes measured in postoperative pathology were ~90% of those measured by preoperative US in PTC; this was not affected by tumor size, the presence of calcification or coexisting thyroiditis. When the surgical extent of PTC treatment according to tumor size measured by US is determined, the relative difference between tumor sizes measured by preoperative US and postoperative pathologic examination should be considered.

  1. Comparison of particle size measurements of some aqueous suspensions by laser polarimetry and dynamic light scattering

    International Nuclear Information System (INIS)

    Chirikov, S N

    2016-01-01

    The results of the size distributions measurements of the particles of aqueous suspensions of ZnO, CuO, TiO 2 , and BaTiO 3 by methods of laser polarimetry and dynamic light scattering are considered. These measurements are compared with the results obtained by electron microscopy. It is shown that a laser polarimetry method gives more accurate results for size parameter values more than 1-2. (paper)

  2. How food marketers can sell smaller portions: Consumer insights and product innovation.

    Science.gov (United States)

    Riis, J; Fisher, J O; Rowe, S

    2016-08-01

    Food portion size has been shown to be an important driver of energy intake. Despite the well acknowledged role of portion control in weight management, large portion sizes remain ubiquitous in the marketplace. Moving consumers towards consumption of smaller portion sizes will require changes in consumer behavior as well as changes in products available to consumers in a variety of settings. This special supplement presents cutting edge research aimed at understanding consumer behavior around portion size and innovations in product design that may promote the selection and consumption of smaller portion sizes. We identify further research that will be needed to translate basic behavioral findings into real world settings and to viable product development. Copyright © 2016. Published by Elsevier Ltd.

  3. Comparison of three methods of measuring vertebral heart size in German Shepherd dogs

    International Nuclear Information System (INIS)

    Spasojevic-Kosic, Lj.; Krstic, N.; Trailovic, R.D.

    2007-01-01

    The method of measuring the heart size in thoracic radiography by comparing it to the length of thoracic vertebrae is marked as vertebral heart size (VHS). Besides of the original VHS measurement suggested by Buchanan and Buecheler, there are modifications of these measurements in literature. With the aim to evaluate differences between different methods of VHS measurement, we compared radiographs of six clinically healthy dogs of the same breed and age (German Shepherd dogs, 3 years of age), whose heart size was measured according to three different methods of VHS measurement. There were not significant differences between the values obtained by different methods of VHS measurement. In our study, we also compared findings of radiographs subjective assessment and VHS measurements. The second and third method of measurement were much more consistent to subjective assessment than the first method. Diagnosis of cardiac abnormalities in dgs should not be based solely on the measuremet of vertebral heart size. However, VHS measurement is very suitable for clinical practice. According to the study reported here, the second method of VHS measurement described in this paper, was recommended

  4. Predicting memory performance in normal ageing using different measures of hippocampal size

    International Nuclear Information System (INIS)

    Lye, T.C.; Creasey, H.; Kril, J.J.; Grayson, D.A.; Piguet, O.; Bennett, H.P.; Ridley, L.J.; Broe, G.A.

    2006-01-01

    A number of different methods have been employed to correct hippocampal volumes for individual variation in head size. Researchers have previously used qualitative visual inspection to gauge hippocampal atrophy. The purpose of this study was to determine the best measure(s) of hippocampal size for predicting memory functioning in 102 community-dwelling individuals over 80 years of age. Hippocampal size was estimated using magnetic resonance imaging (MRI) volumetry and qualitative visual assessment. Right and left hippocampal volumes were adjusted by three different estimates of head size: total intracranial volume (TICV), whole-brain volume including ventricles (WB+V) and a more refined measure of whole-brain volume with ventricles extracted (WB). We compared the relative efficacy of these three volumetric adjustment methods and visual ratings of hippocampal size in predicting memory performance using linear regression. All four measures of hippocampal size were significant predictors of memory performance. TICV-adjusted volumes performed most poorly in accounting for variance in memory scores. Hippocampal volumes adjusted by either measure of whole-brain volume performed equally well, although qualitative visual ratings of the hippocampus were at least as effective as the volumetric measures in predicting memory performance in community-dwelling individuals in the ninth or tenth decade of life. (orig.)

  5. Measurements of the size dependence of the concentration of nonvolatile material in fog droplets

    Science.gov (United States)

    Ogren, J. A.; Noone, K. J.; Hallberg, A.; Heintzenberg, J.; Schell, D.; Berner, A.; Solly, I.; Kruisz, C.; Reischl, G.; Arends, B. G.; Wobrock, W.

    1992-11-01

    Measurements of the size dependence of the mass concentration of nonvolatile material dissolved and suspended in fog droplets were obtained with three complementary approaches, covering a size range from c. 1 50µm diameter: a counterflow virtual impactor, an eight-stage aerosol impactor, and a two-stage fogwater impactor. Concentrations were observed to decrease with size over the entire range, contrary to expectations of increasing concentrations at larger sizes. It is possible that the larger droplets had solute concentrations that increased with increasing size, but that the increase was too weak for the measurements to resolve. Future studies should consider the hypothesis that the droplets were coated with a surface-active substance that hindered their uptake of water.

  6. Cuff size influences blood pressure measurement in obese children and adolescents

    DEFF Research Database (Denmark)

    Muhamed, P. K.; Olsen, M. H.; Holm, Jens-Christian

    2016-01-01

    Introduction: Recently, we established that a group ofobese children and adolescents had a higher blood pressure(BP) than a healthy control group. In the present study, weinvestigate whether the higher BP in the obese group wasinfluenced by BP cuff sizes.Methods: A total of 104 obese patients aged...... sizes had a significant impact on BP measurements.Despite the influence of cuff size, multiple regressionanalyses revealed that systolic BP was 68 mmHg higherand diastolic BP 32 mmHg higher in the obese groupthan in the control group. A step function, i.e. a sudden fallin BP, was seen at the point...... of switching from small to mediumcuff size in the control group, which suggests that systolicBP was overestimated when using small cuff size andunderestimated when using medium cuff size in subjectswith an AC near 23 cm.Conclusions: BP was higher in the obese group than inthe control group although BP...

  7. Robust organelle size extractions from elastic scattering measurements of single cells (Conference Presentation)

    Science.gov (United States)

    Cannaday, Ashley E.; Draham, Robert; Berger, Andrew J.

    2016-04-01

    The goal of this project is to estimate non-nuclear organelle size distributions in single cells by measuring angular scattering patterns and fitting them with Mie theory. Simulations have indicated that the large relative size distribution of organelles (mean:width≈2) leads to unstable Mie fits unless scattering is collected at polar angles less than 20 degrees. Our optical system has therefore been modified to collect angles down to 10 degrees. Initial validations will be performed on polystyrene bead populations whose size distributions resemble those of cell organelles. Unlike with the narrow bead distributions that are often used for calibration, we expect to see an order-of-magnitude improvement in the stability of the size estimates as the minimum angle decreases from 20 to 10 degrees. Scattering patterns will then be acquired and analyzed from single cells (EMT6 mouse cancer cells), both fixed and live, at multiple time points. Fixed cells, with no changes in organelle sizes over time, will be measured to determine the fluctuation level in estimated size distribution due to measurement imperfections alone. Subsequent measurements on live cells will determine whether there is a higher level of fluctuation that could be attributed to dynamic changes in organelle size. Studies on unperturbed cells are precursors to ones in which the effects of exogenous agents are monitored over time.

  8. Field size dependence of wedge factor: miniphantom vs full phantom measurements

    International Nuclear Information System (INIS)

    Allen Li, X.; Szanto, J.; Soubra, M.; Gerig, L. H.

    1995-01-01

    It is empirically known that the transmission factor for wedge in a high-energy photon beam is dependent upon field size and depth of measurement. The field-size dependence of wedge factors may be attributed to changes in (i) head scatter, (ii) phantom scatter, and (iii) backscatter from the wedge into the linac monitor chamber. In this work we present the results of studies designed to examine each of these factors in isolation. The wedge factors for wedges with nominal wedge angles of 15 deg. , 30 deg. , 45 deg. and 60 deg. were measured with a 3-g/cm 2 -diameter narrow cylindrical phantom (miniphantom), a brass cap with 1.5-g/cm 2 side-wall thickness and a full water phantom for 6-, 10- and 18-MV photon beams. The measurements were performed with and without flattening filter in place. The wedge factors measured with the miniphantom and the brass cap exclude the phantom scatter contribution. It has been found that the field-size behaviour of wedge factor measured with full water phantom is similar to that measured with the miniphantom and cap. This indicates that the head scatter radiation is the major contributor to the field size dependence of wedge factors. Wedge factors measured with water phantom are up to 5.0% smaller than those measured with miniphantom. This difference increases with wedge angle. When Measured with the flattening filter removed, the field size dependence of the wedge factor is reduced. This justify that the flattening filter is one of the major contributors to head scatters. The measurement results made with the brass cap agree well with those made by using the miniphantom. By measuring the monitor chamber output, it is found that the backscatters from the wedge into the linac ion chamber have little effect on the field size dependence of the wedge factor

  9. The size effect of searching window for measuring wavefront of laser beam

    International Nuclear Information System (INIS)

    Park, Seung Kyu; Baik, Sung Hoon; Lim, Chang Hwan; Kim, Jung Cheol; Yi, Seung Jun; Ra, Sung Woong

    2003-01-01

    We investigated the size effect of the searching window for measuring of a laser beam using a Shack-Hartmann sensor. The shapes of spot images on an acquired wavefront image by using a Shack-Hartmann sensor are usually imbalanced. Also, the distributed intensity pattern of each spot image is varied according to successively acquired wavefront image. We studied on the optimized size of searching window to get wavefront with high measurement resolution. We experimented on the various size effect of searching window on an acquired wavefront image to get fine wavefront information using a Shack-Hartmann sensor. As the experimental results, we proposed the optimum size of searching window to measure improved wavefront.

  10. Measurement and analysis of the concentration and size distribution of aerosols in a copper mine

    International Nuclear Information System (INIS)

    Li Dehong; Zhuo Weihai; Huang Gang; Su Xu; Sun Quanfu

    2008-01-01

    Objective: To explore the general characteristics of the concentration and size distribution of aerosols in a mine. Methods: In different areas of a non-uranium mine, the particle number and mass concentration of aerosols were surveyed with a condensation particle counter and a personal aerosol monitor, respectively, and the size distribution of aerosols larger than 1 μm in size was estimated according to the size- selective measurements of mass concentrations. The size distribution of submicron aerosols was evaluated based on the method of screen diffusion battery (SOB), and the measurements were performed in both inside and outside of a control room. Results: The mass concentration of inhaled particles (PM10) was averaged to be 0.42 mg/m 3 in the whole mine, and it varied with different working areas and significantly affected with human activities. In the mine, particles lager than 1 μm in size widely distributed, while the particles less than 5 nm in size were seldom observed. Conclusions: The characteristics of aerosol significantly change with different working areas, human activities and Antilation condition in mine. The dose contribution from inhaled radioactive particles larger than 1 μm in size should be considered in mine. (authors)

  11. Influence of the in-plane artefact in chest tomosynthesis on pulmonary nodule size measurements

    International Nuclear Information System (INIS)

    Soederman, Christina; Allansdotter Johnsson, Aase; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus

    2016-01-01

    The aim of the present study was to investigate how the in-plane artefact present in the scan direction around structures in tomosynthesis images should be managed when measuring the size of nodules in chest tomosynthesis images in order to achieve acceptable measurement accuracy. Data from measurements, performed by radiologists, of the longest diameter of artificial nodules inserted in chest tomosynthesis images were used. The association between the measurement error and the direction of the longest nodule diameter, relative to the scan direction, was evaluated using the Kendall rank correlation coefficient. All of the radiologists had chosen to not include the artefact in the measurements. Significant association between measurement error and the direction of the longest diameter was found for nodules larger than 12 mm, which indicates that, for these nodules, there is a risk of underestimating the nodule size if the in-plane artefact is omitted from manual diameter measurements. (authors)

  12. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    Science.gov (United States)

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x

  13. Generalized procedures for determining inspection sample sizes (related to quantitative measurements). Vol. 1: Detailed explanations

    International Nuclear Information System (INIS)

    Jaech, J.L.; Lemaire, R.J.

    1986-11-01

    Generalized procedures have been developed to determine sample sizes in connection with the planning of inspection activities. These procedures are based on different measurement methods. They are applied mainly to Bulk Handling Facilities and Physical Inventory Verifications. The present report attempts (i) to assign to appropriate statistical testers (viz. testers for gross, partial and small defects) the measurement methods to be used, and (ii) to associate the measurement uncertainties with the sample sizes required for verification. Working papers are also provided to assist in the application of the procedures. This volume contains the detailed explanations concerning the above mentioned procedures

  14. Simultaneous aerosol size distribution and turbidity measurements over St. Louis during METROMEX 1975

    International Nuclear Information System (INIS)

    Laulainen, N.S.; Alkezweeny, A.J.; Thorp, J.M.

    1978-01-01

    An experiment designed to measure aerosol size distributions and turbidity simultaneously over a metropolitan area is described. The particle volume size distributions measured in the city plume are found to be bimodal, with the total particle volume in the fine or submicron mode decreasing dramatically above the inversion. Aerosol extinction coefficients derived from sunphotometer optical depth measurements at four wavelengths are compared to those calculated from the measured size distributions using Mie theory with several different particle refractive indices. The accuracy of the experimental method for determining the aerosol extinction coefficient prevented any meaningful choice of the real part of particle refractive index between 1.5--1.6 and an imaginary part between 0 and -0.1i. Improvements to this type of experiment are discussed

  15. Finite-size analysis of continuous-variable measurement-device-independent quantum key distribution

    Science.gov (United States)

    Zhang, Xueying; Zhang, Yichen; Zhao, Yijia; Wang, Xiangyu; Yu, Song; Guo, Hong

    2017-10-01

    We study the impact of the finite-size effect on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, mainly considering the finite-size effect on the parameter estimation procedure. The central-limit theorem and maximum likelihood estimation theorem are used to estimate the parameters. We also analyze the relationship between the number of exchanged signals and the optimal modulation variance in the protocol. It is proved that when Charlie's position is close to Bob, the CV-MDI QKD protocol has the farthest transmission distance in the finite-size scenario. Finally, we discuss the impact of finite-size effects related to the practical detection in the CV-MDI QKD protocol. The overall results indicate that the finite-size effect has a great influence on the secret-key rate of the CV-MDI QKD protocol and should not be ignored.

  16. Small-sized reverberation chamber for the measurement of sound absorption

    International Nuclear Information System (INIS)

    Rey, R. del; Alba, J.; Bertó, L.; Gregori, A.

    2017-01-01

    This paper presents the design, construction, calibration and automation of a reverberation chamber for small samples. A balance has been sought between reducing sample size, to reduce the manufacturing costs of materials, and finding the appropriate volume of the chamber, to obtain reliable values at high and mid frequencies. The small-sized reverberation chamber, that was built, has a volume of 1.12 m3 and allows for the testing of samples of 0.3 m2. By using diffusers, to improve the diffusion degree, and automating measurements, we were able to improve the reliability of the results, thus reducing test errors. Several comparison studies of the measurements of the small-sized reverberation chamber and the standardised reverberation chamber are shown, and a good degree of adjustment can be seen between them, within the range of valid frequencies. This paper presents a small laboratory for comparing samples and making decisions before the manufacturing of larger sizes. [es

  17. Near surface illumination method to detect particle size information by optical calibration free remission measurements

    Science.gov (United States)

    Stocker, Sabrina; Foschum, Florian; Kienle, Alwin

    2017-07-01

    A calibration free method to detect particle size information is presented. A possible application for such measurements is the investigation of raw milk since there not only the fat and protein content varies but also the fat droplet size. The newly developed method is sensitive to the scattering phase function, which makes it applicable to many other applications, too. By simulating the light propagation by use of Monte Carlo simulations, a calibration free device can be developed from this principle.

  18. Indoor radon progeny aerosol size measurements in urban, suburban, and rural regions

    International Nuclear Information System (INIS)

    Tu, K.W.; Knutson, E.O.; George, A.C.

    1991-01-01

    By using direct and indirect methods, the authors conducted size distribution measurements of radon progeny particles in a variety of indoor environments in urban, suburban, and rural areas. The radon progeny particle size distribution owing to indoor activities has two definable source categories: (1) gas combustion from stoves and kerosene heaters - particles were found to be smaller than 0.1 μm in diameter, mostly in the range 0.02-0.08 μm; and (2) cigarette smoking and food frying - particles were found to be larger, in the size range 0.1-0.2 μm. The radon progeny particle size distribution, without significant indoor activities, such as cooking, was found to be larger in rural areas than in urban or suburban areas. The modal diameters of the size spectra in the rural areas were two to three times larger than those in urban or suburban areas, around 0.3-0.4 bs. 0.1-0.2 μm. Results obtained by applying the attachment theory to the measured number-weighted size spectra from an electrical aerosol size analyzer support this finding. These results, if confirmed by more extensive studies, will be useful for the assessment of the risk from the inhalation of radon progeny in various indoor environments

  19. Drop size distribution measured by imaging: determination of the measurement volume by the calibration of the point spread function

    International Nuclear Information System (INIS)

    Fdida, Nicolas; Blaisot, Jean-Bernard

    2010-01-01

    Measurement of drop size distributions in a spray depends on the definition of the control volume for drop counting. For image-based techniques, this implies the definition of a depth-of-field (DOF) criterion. A sizing procedure based on an imaging model and associated with a calibration procedure is presented. Relations between image parameters and object properties are used to provide a measure of the size of the droplets, whatever the distance from the in-focus plane. A DOF criterion independent of the size of the drops and based on the determination of the width of the point spread function (PSF) is proposed. It allows to extend the measurement volume to defocused droplets and, due to the calibration of the PSF, to clearly define the depth of the measurement volume. Calibrated opaque discs, calibrated pinholes and an optical edge are used for this calibration. A comparison of the technique with a phase Doppler particle analyser and a laser diffraction granulometer is performed on an application to an industrial spray. Good agreement is found between the techniques when particular care is given to the sampling of droplets. The determination of the measurement volume is used to determine the drop concentration in the spray and the maximum drop concentration that imaging can support

  20. Finding the magnetic size distribution of magnetic nanoparticles from magnetization measurements via the iterative Kaczmarz algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Daniel, E-mail: frank.wiekhorst@ptb.de; Eberbeck, Dietmar; Steinhoff, Uwe; Wiekhorst, Frank

    2017-06-01

    The characterization of the size distribution of magnetic nanoparticles is an important step for the evaluation of their suitability for many different applications like magnetic hyperthermia, drug targeting or Magnetic Particle Imaging. We present a new method based on the iterative Kaczmarz algorithm that enables the reconstruction of the size distribution from magnetization measurements without a priori knowledge of the distribution form. We show in simulations that the method is capable of very exact reconstructions of a given size distribution and, in that, is highly robust to noise contamination. Moreover, we applied the method on the well characterized FeraSpin™ series and obtained results that were in accordance with literature and boundary conditions based on their synthesis via separation of the original suspension FeraSpin R. It is therefore concluded that this method is a powerful and intuitive tool for reconstructing particle size distributions from magnetization measurements. - Highlights: • A new method for the size distribution fit of magnetic nanoparticles is proposed. • Employed Kaczmarz algorithm does not need a priori input or eigenwert regularization. • The method is highly robust to noise contamination. • Size distributions are reconstructed from simulated and measured magnetization curves.

  1. Geometric measures of multipartite entanglement in finite-size spin chains

    Energy Technology Data Exchange (ETDEWEB)

    Blasone, M; Dell' Anno, F; De Siena, S; Giampaolo, S M; Illuminati, F, E-mail: illuminati@sa.infn.i [Dipartimento di Matematica e Informatica, Universita degli Studi di Salerno, Via Ponte don Melillo, I-84084 Fisciano (Italy)

    2010-09-01

    We investigate the behaviour of multipartite entanglement in finite-size quantum spin systems, resorting to a hierarchy of geometric measures of multipartite entanglement recently introduced in the literature. In particular, we investigate the ground-state entanglement in the XY model defined on finite chains of N sites with periodic boundary conditions. We analyse the behaviour of the geometric measures of (N- 1)-partite and (N/2)-partite entanglement and compare them with the Wei-Goldbart geometric measure of global entanglement.

  2. Geometric measures of multipartite entanglement in finite-size spin chains

    International Nuclear Information System (INIS)

    Blasone, M; Dell'Anno, F; De Siena, S; Giampaolo, S M; Illuminati, F

    2010-01-01

    We investigate the behaviour of multipartite entanglement in finite-size quantum spin systems, resorting to a hierarchy of geometric measures of multipartite entanglement recently introduced in the literature. In particular, we investigate the ground-state entanglement in the XY model defined on finite chains of N sites with periodic boundary conditions. We analyse the behaviour of the geometric measures of (N- 1)-partite and (N/2)-partite entanglement and compare them with the Wei-Goldbart geometric measure of global entanglement.

  3. Analysis of the Indentation Size Effect in the Microhardness Measurements in B6O

    OpenAIRE

    Ronald Machaka; Trevor E. Derry; Iakovos Sigalas; Mathias Herrmann

    2011-01-01

    The Vickers microhardness measurements of boron suboxide (B6O) ceramics prepared by uniaxial hot-pressing was investigated at indentation test loads in the range from 0.10 to 2.0 kgf. Results from the investigation indicate that the measured microhardness exhibits an indentation load dependence. Based on the results, we present a comprehensive model intercomparison study of indentation size effects (ISEs) in the microhardness measurements of hot-pressed B6O discussed using existing models, th...

  4. Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.

    Science.gov (United States)

    Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon

    2018-04-01

    The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Retrieval of cloud droplet size distribution parameters from polarized reflectance measurements

    Directory of Open Access Journals (Sweden)

    M. Alexandrov

    2011-09-01

    Full Text Available We present an algorithm for retrieval of cloud droplet size distribution parameters (effective radius and variance from the Research Scanning Polarimeter (RSP measurements. The RSP is an airborne prototype for the Aerosol Polarimetery Sensor (APS, which is due to be launched as part of the NASA Glory Project. This instrument measures both polarized and total reflectances in 9 spectral channels with center wavelengths ranging from 410 to 2250 nm. For cloud droplet size retrievals we utilize the polarized reflectances in the scattering angle range between 140 and 170 degrees where they exhibit rainbow. The shape of the rainbow is determined mainly by single-scattering properties of the cloud particles, that simplifies the inversions and reduces retrieval uncertainties. The retrieval algorithm was tested using realistically simulated cloud radiation fields. Our retrievals of cloud droplet sizes from actual RSP measurements made during two recent field campaigns were compared with the correlative in situ observations.

  6. Very small beam-size measurement by a reflective synchrotron radiation interferometer

    Directory of Open Access Journals (Sweden)

    T. Naito

    2006-12-01

    Full Text Available A synchrotron radiation (SR interferometer with Herschelian reflective optics has been developed for the measurement of beams of several μm in size. In a conventional refractive SR interferometer, the dispersion effect of the objective lens limits the instrument to a smaller range of beam-size measurements. To avoid this problem, we designed a Herschelian arrangement of reflective optics for the interferometer. The effectiveness of the reflective SR interferometer was confirmed at the KEK Accelerator Test Facility (ATF damping ring. The measured vertical beam size obtained using the reflective SR interferometer was 4.7   μm and the estimated vertical emittance was 0.97×10^{-11}   m.

  7. A study on the measurement of flaw sizes by acoustical holography

    International Nuclear Information System (INIS)

    Yamamoto, M.; Ando, T.; Enami, K.; Yajima, M.; Fukui, S.

    1978-01-01

    As a means of evaluating the safety of flawed pressure vessels and other structures against fracture, fracture mechanics has come to be applied. For the application of fracture mechanics it is necessary to get information concerning the sizes and shapes of flaws. The ultrasonic flaw detection method which is widely used as a nondestructive inspection method cannot measure the sizes and shapes of flaws accurately. Considering that acoustical holography is an useful means for the measurement of flaws, we performed basic tests on this method and obtained the following results: (1) The measured values of artificial flaws (flat bottom drilled holes: 5 -- 36 mm) made on a steel plate with a thickness of 150 mm showed a good linear relation with their actual sizes and scatter in the measured values was +-3 -- 6 mm. (2) The measured values of fatigue cracks (length: 5 -- 57 mm) introduced into a steel plate with thickness of 150 mm also showed a good linear relation with their actual sizes and scatter in the measured values was +-3 mm. (3) It was found that acoustical holography can also be applied to heavy section cast steels. (4) The method of correcting distortion caused by curved surface was investigated by computer-aided simulation and it was considered that such distortion can be corrected by radial scanning of a transducer. (auth.)

  8. Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot

    Science.gov (United States)

    Lane, John

    2013-01-01

    The optical extinction of a laser due to scattering of particles is a well-known phenomenon. In a laboratory environment, this physical principle is known as the Beer-Lambert law, and is often used to measure the concentration of scattering particles in a fluid or gas. This method has been experimentally shown to be a usable means to measure the dust density from a rocket plume interaction with the lunar surface. Using the same principles and experimental arrangement, this technique can be applied to hydrometeor size distributions, and for launch-pad operations, specifically as a passive hail detection and measurement system. Calibration of a hail monitoring system is a difficult process. In the past, it has required comparison to another means of measuring hydrometeor size and density. Using a technique recently developed for estimating the density of surface dust dispersed during a rocket landing, measuring the extinction of a laser passing through hail (or dust in the rocket case) yields an estimate of the second moment of the particle cloud, and hydrometeor size distribution in the terrestrial meteorological case. With the exception of disdrometers, instruments that measure rain and hail fall make indirect measurements of the drop-size distribution. Instruments that scatter microwaves off of hydrometeors, such as the WSR-88D (Weather Surveillance Radar 88 Doppler), vertical wind profilers, and microwave disdrometers, measure the sixth moment of the drop size distribution (DSD). By projecting a laser onto a target, changes in brightness of the laser spot against the target background during rain and hail yield a measurement of the DSD's second moment by way of the Beer-Lambert law. In order to detect the laser attenuation within the 8-bit resolution of most camera image arrays, a minimum path length is required. Depending on the intensity of the hail fall rate for moderate to heavy rainfall, a laser path length of 100 m is sufficient to measure variations in

  9. Electrode size and boundary condition independent measurement of the effective piezoelectric coefficient of thin films

    Directory of Open Access Journals (Sweden)

    M. Stewart

    2015-02-01

    Full Text Available The determination of the piezoelectric coefficient of thin films using interferometry is hindered by bending contributions. Using finite element analysis (FEA simulations, we show that the Lefki and Dormans approximations using either single or double-beam measurements cannot be used with finite top electrode sizes. We introduce a novel method for characterising piezoelectric thin films which uses a differential measurement over the discontinuity at the electrode edge as an internal reference, thereby eliminating bending contributions. This step height is shown to be electrode size and boundary condition independent. An analytical expression is derived which gives good agreement with FEA predictions of the step height.

  10. A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Hwan [Dept. of Radiological Technology, Dongnam Health College, Suwon (Korea, Republic of); Kim, Yun Min [Dept. of Diagnostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Choi, Jun Gu [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2008-06-15

    Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000 cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33 cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94 cm, and the average length in the left kidney was 11.13 cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in

  11. A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Kim, Yun Min; Choi, Jun Gu

    2008-01-01

    Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000 cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33 cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94 cm, and the average length in the left kidney was 11.13 cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the

  12. Effects of drop size and measuring condition on static contact angle measurement on a superhydrophobic surface with goniometric technique

    International Nuclear Information System (INIS)

    Seo, Kwangseok; Kim, Minyoung; Kim, Do Hyun; Ahn, Jeong Keun

    2015-01-01

    It is not a simple task to measure a contact angle of a water drop on a superhydrophobic surface with sessile drop method, because a roll-off angle is very low. Usually contact angle of a water drop on a superhydrophobic surface is measured by fixing a drop with intentional defects on the surface or a needle. We examined the effects of drop size and measuring condition such as the use of a needle or defects on the static contact angle measurement on superhydrophobic surface. Results showed that the contact angles on a superhydrophobic surface remain almost constant within intrinsic measurement errors unless there is a wetting transition during the measurement. We expect that this study will provide a deeper understanding on the nature of the contact angle and convenient measurement of the contact angle on the superhydrophobic surface.

  13. E-line: A new crystal collimator beam line for source size measurements at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    White, Jeffrey A. [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)], E-mail: jaw7@cornell.edu; Revesz, Peter; Finkelstein, Ken [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)

    2007-11-11

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring.

  14. E-line: A new crystal collimator beam line for source size measurements at CHESS

    International Nuclear Information System (INIS)

    White, Jeffrey A.; Revesz, Peter; Finkelstein, Ken

    2007-01-01

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring

  15. Particle size distribution properties in mixed-phase monsoon clouds from in situ measurements during CAIPEEX

    Science.gov (United States)

    Patade, Sachin; Prabha, T. V.; Axisa, D.; Gayatri, K.; Heymsfield, A.

    2015-10-01

    A comprehensive analysis of particle size distributions measured in situ with airborne instrumentation during the Cloud Aerosol Interaction and Precipitation Enhancement Experiment (CAIPEEX) is presented. In situ airborne observations in the developing stage of continental convective clouds during premonsoon (PRE), transition, and monsoon (MON) period at temperatures from 25 to -22°C are used in the study. The PRE clouds have narrow drop size and particle size distributions compared to monsoon clouds and showed less development of size spectra with decrease in temperature. Overall, the PRE cases had much lower values of particle number concentrations and ice water content compared to MON cases, indicating large differences in the ice initiation and growth processes between these cloud regimes. This study provided compelling evidence that in addition to dynamics, aerosol and moisture are important for modulating ice microphysical processes in PRE and MON clouds through impacts on cloud drop size distribution. Significant differences are observed in the relationship of the slope and intercept parameters of the fitted particle size distributions (PSDs) with temperature in PRE and MON clouds. The intercept values are higher in MON clouds than PRE for exponential distribution which can be attributed to higher cloud particle number concentrations and ice water content in MON clouds. The PRE clouds tend to have larger values of dispersion of gamma size distributions than MON clouds, signifying narrower spectra. The relationships between PSDs parameters are presented and compared with previous observations.

  16. Optimal sample preparation for nanoparticle metrology (statistical size measurements) using atomic force microscopy

    International Nuclear Information System (INIS)

    Hoo, Christopher M.; Doan, Trang; Starostin, Natasha; West, Paul E.; Mecartney, Martha L.

    2010-01-01

    Optimal deposition procedures are determined for nanoparticle size characterization by atomic force microscopy (AFM). Accurate nanoparticle size distribution analysis with AFM requires non-agglomerated nanoparticles on a flat substrate. The deposition of polystyrene (100 nm), silica (300 and 100 nm), gold (100 nm), and CdSe quantum dot (2-5 nm) nanoparticles by spin coating was optimized for size distribution measurements by AFM. Factors influencing deposition include spin speed, concentration, solvent, and pH. A comparison using spin coating, static evaporation, and a new fluid cell deposition method for depositing nanoparticles is also made. The fluid cell allows for a more uniform and higher density deposition of nanoparticles on a substrate at laminar flow rates, making nanoparticle size analysis via AFM more efficient and also offers the potential for nanoparticle analysis in liquid environments.

  17. Simultaneous measurement of particle velocity and size based on gray difference and autocorrelation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The gray of two images of a same particle taken by a digital camera with different exposure times is different too. Based on the gray difference of particle images in a double-exposed photo and autocorrelation processing of digital images,this paper proposes a method for measuring particle velocities and sizes simultaneously. This paper also introduces the theoretical foundation of this method,the process of particle imaging and image processing,and the simultaneous measurement of velocity and size of a low speed flow field with 35 μm and 75 μm standard particles. The graphical measurement results can really reflect the flow characteristics of the flow field. In addition,although the measured velocity and size histograms of these two kinds of standard particles are slightly wider than the theoretical ones,they are all still similar to the normal distribution,and the peak velocities and diameters of the histograms are consistent with the default values. Therefore,this measurement method is capable of providing moderate measurement accuracy,and it can be further developed for high-speed flow field measurements.

  18. New analysis procedure for fast and reliable size measurement of nanoparticles from atomic force microscopy images

    International Nuclear Information System (INIS)

    Boyd, Robert D.; Cuenat, Alexandre

    2011-01-01

    Accurate size measurement during nanoparticle production is essential for the continuing innovation, quality and safety of nano-enabled products. Size measurement by analysing a number of separate particles individually has particular advantages over ensemble methods. In the latter case nanoparticles have to be well dispersed in a fluid and changes that may occur during analysis, such as agglomeration and degradation, will not be detected which could lead to misleading results. Atomic force microscopy (AFM) allows imaging of particles both in air and liquid, however, the strong interactions between the probe and the particle will cause the broadening of the lateral dimension in the final image. In this paper a new procedure to measure the size of spherical nanoparticles from AFM images via vertical height measurement is described. This procedure will quickly analyse hundred of particles simultaneously and reproduce the measurements obtained from electron microscopy (EM). Nanoparticles samples that were difficult, if not impossible, to analyse with EM were successfully measured using this method. The combination of this procedure with the use of a metrological AFM moves closer to true traceable measurements of nanoparticle dispersions.

  19. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    Science.gov (United States)

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  20. Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.

    Science.gov (United States)

    Elleaume, P; Fortgang, C; Penel, C; Tarazona, E

    1995-09-01

    A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.

  1. Measurement of concentration and size distribution of radon decay products in homes using air cleaners

    International Nuclear Information System (INIS)

    Montassier, N.; Hopke, P.K.; Shi, Y.; McCallum, B.

    1992-01-01

    By removing particles, air cleaners can also eliminate radon decay products. However, by removing the particles, the open-quotes unattachedclose quotes fraction of the radon progeny is increased leading to a higher dose per unit exposure. Thus, both the concentration and size distributions of the radon decay products are needed to evaluate air cleaners. Three types of room air cleaners, NO-RAD Radon Removal System, Electronic Air Cleaner and PUREFLOW Air Treatment System were tested in a single family home in Arnprior, Ontario (Canada). Semi-continuous measurements of radon gas concentration and radon decay product activity weighted size distribution were performed in the kitchen/dining room under real living conditions. The effects of air cleaners on both the concentration and size distribution of the radon decay products were measured, and their impact on the dose of radiation given to the lung tissue were examined

  2. A NEW RECIPE FOR OBTAINING CENTRAL VOLUME DENSITIES OF PRESTELLAR CORES FROM SIZE MEASUREMENTS

    International Nuclear Information System (INIS)

    Tassis, Konstantinos; Yorke, Harold W.

    2011-01-01

    We propose a simple analytical method for estimating the central volume density of prestellar molecular cloud cores from their column density profiles. Prestellar cores feature a flat central part of the column density and volume density profiles of the same size indicating the existence of a uniform-density inner region. The size of this region is set by the thermal pressure force which depends only on the central volume density and temperature of the core, and can provide a direct measurement of the central volume density. Thus, a simple length measurement can immediately yield a central density estimate independent of any dynamical model for the core and without the need for fitting. Using the radius at which the column density is 90% of the central value as an estimate of the size of the flat inner part of the column density profile yields an estimate of the central volume density within a factor of two for well-resolved cores.

  3. Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-06-01

    To reduce drooling and facilitate food transport in rehabilitation of patients with oral motor dysfunction, lip force can be trained using an oral screen. Longitudinal studies evaluating the effect of training require objective methods. The aim of this study was to evaluate a method for measuring lip strength, to investigate normal values and fluctuation of lip force in healthy adults on 1 occasion and over time, to study how the size of the screen affects the force, to evaluate the most appropriate measure of reliability, and to identify force performed in relation to gender. Three different sizes of oral screens were used to measure the lip force for 24 healthy adults on 3 different occasions, during a period of 6 months, using an apparatus based on strain gauge. The maximum lip force as evaluated with this method depends on the area of the screen size. By calculating the projected area of the screen, the lip force could be normalized to an oral screen pressure quantity expressed in kPa, which can be used for comparing measurements from screens with different sizes. Both the mean value and standard deviation were shown to vary between individuals. The study showed no differences regarding gender and only small variation with age. Normal variation over time (months) may be up to 3 times greater than the standard error of measurement at a certain occasion. The lip force increases in relation to the projected area of the screen. No general standard deviation can be assigned to the method and all measurements should be analyzed individually based on oral screen pressure to compensate for different screen sizes.

  4. New Measurements of the Particle Size Distribution of Apollo 11 Lunar Soil 10084

    Science.gov (United States)

    McKay, D.S.; Cooper, B.L.; Riofrio, L.M.

    2009-01-01

    We have initiated a major new program to determine the grain size distribution of nearly all lunar soils collected in the Apollo program. Following the return of Apollo soil and core samples, a number of investigators including our own group performed grain size distribution studies and published the results [1-11]. Nearly all of these studies were done by sieving the samples, usually with a working fluid such as Freon(TradeMark) or water. We have measured the particle size distribution of lunar soil 10084,2005 in water, using a Microtrac(TradeMark) laser diffraction instrument. Details of our own sieving technique and protocol (also used in [11]). are given in [4]. While sieving usually produces accurate and reproducible results, it has disadvantages. It is very labor intensive and requires hours to days to perform properly. Even using automated sieve shaking devices, four or five days may be needed to sieve each sample, although multiple sieve stacks increases productivity. Second, sieving is subject to loss of grains through handling and weighing operations, and these losses are concentrated in the finest grain sizes. Loss from handling becomes a more acute problem when smaller amounts of material are used. While we were able to quantitatively sieve into 6 or 8 size fractions using starting soil masses as low as 50mg, attrition and handling problems limit the practicality of sieving smaller amounts. Third, sieving below 10 or 20microns is not practical because of the problems of grain loss, and smaller grains sticking to coarser grains. Sieving is completely impractical below about 5- 10microns. Consequently, sieving gives no information on the size distribution below approx.10 microns which includes the important submicrometer and nanoparticle size ranges. Finally, sieving creates a limited number of size bins and may therefore miss fine structure of the distribution which would be revealed by other methods that produce many smaller size bins.

  5. Association between placentome size, measured using transrectal ultrasonography, and gestational age in cattle.

    Science.gov (United States)

    Adeyinka, F D; Laven, R A; Lawrence, K E; van Den Bosch, M; Blankenvoorde, G; Parkinson, T J

    2014-03-01

    The aim of this study was to estimate whether fetal age could be accurately estimated using placentome size. Fifty-eight cows with confirmed conception dates in two herds were used for the study. The length of the long axis and cross-sectional area of placentomes close to the cervix were measured once every 10 days between approximately 60-130 days of gestation and once every 15 days between 130-160 days of gestation. Four to six placentomes were measured using transrectal ultrasonography in each uterine horn. A linear mixed model was used to establish the factors that were significantly associated with log mean placentome length and to create an equation to predict gestational age from mean placentome length. Limits of agreement analysis was then used to evaluate whether the predictions were sufficiently accurate for mean placentome length to be used, in practice, as a method of determining gestational age. Only age of gestation (puterine horn (p=0.048) were found to have a significant effect on log mean placentome length. From the three models used to predict gestational age the one that used log mean placentome length of all placentomes, adjusting for the effect of horn, had the smallest 95% limits of agreement; ±33 days. That is, predicted gestational age had a 95% chance of being between 33 days greater and 33.7 days less than actual age. This is approximately twice that reported in studies using measurement of fetal size. Measurement of placentomes near to the cervix using transrectal ultrasonography was easily achieved. There was a significant association between placentome size and gestational age, but between-cow variation in placentome size and growth resulted in poor agreement between placentome size and gestational age. Although placentomes can be easily visualised during diagnosis of pregnancy using transrectal ultrasonography, mean placentome size should not be used to estimate gestational age.

  6. Standardized Effect Size Measures for Mediation Analysis in Cluster-Randomized Trials

    Science.gov (United States)

    Stapleton, Laura M.; Pituch, Keenan A.; Dion, Eric

    2015-01-01

    This article presents 3 standardized effect size measures to use when sharing results of an analysis of mediation of treatment effects for cluster-randomized trials. The authors discuss 3 examples of mediation analysis (upper-level mediation, cross-level mediation, and cross-level mediation with a contextual effect) with demonstration of the…

  7. Application of porous foams for size-selective measurements of airborne wheat allergen

    NARCIS (Netherlands)

    Bogdanovic, J.; Pater, A.J. de; Doekes, G.; Wouters, I.M.; Heederik, D.J.J.

    2006-01-01

    Background: Exposure to airborne wheat allergen is a well-known cause of bakers' allergy and asthma. Airborne wheat allergen can be measured by enzyme immunoassays (EIAs) in extracts of inhalable dust samples, but only limited knowledge is available on the size distribution of wheat

  8. Improved Pedagogy for Linear Differential Equations by Reconsidering How We Measure the Size of Solutions

    Science.gov (United States)

    Tisdell, Christopher C.

    2017-01-01

    For over 50 years, the learning of teaching of "a priori" bounds on solutions to linear differential equations has involved a Euclidean approach to measuring the size of a solution. While the Euclidean approach to "a priori" bounds on solutions is somewhat manageable in the learning and teaching of the proofs involving…

  9. Doubling Your Sunsets or How Anyone Can Measure the Earth's Size with Wristwatch and Meterstick.

    Science.gov (United States)

    Rawlins, Dennis

    1979-01-01

    Describes a simple method to measure the size of the Earth to an accuracy of order of magnitude 10 percent. The procedure involves finding the time interval between two sunsets, a sunset observed at sea level while lying down, and a sunset viewed at eye height after standing up. (GA)

  10. Novel Volumetric Size and Velocity Measurement of Particles Using Interferometric Laser Imaging

    Science.gov (United States)

    Gunawardana, R.; Zarzecki, M.; Diez, F. J.

    2008-11-01

    Global Sizing Velocimetry (GSV) is a recently developed technique for characterizing the particle size distribution and flow velocity in a plane and in this research we extend this measurement to a volume through a laser scanning system. In GSV, a LASER sheet is used to illuminate translucent particles in a spray or flow field and the camera image is de-focused a known distance to create interference patterns. The diameters of the particles in the flow field are calculated by measuring the inter-fringe spacing in the resulting interferogram. Particle Imaging Velocimetry (PIV) techniques are used to compute velocity by measuring the particle displacement over a known short time interval. Researchers have recently begun applying GSV techniques to characterize sprays in a plane as it offers a larger area of investigation than other well known techniques such as Phase Doppler Anemometry (PDA). In this paper we extend GSA techniques from the current planar measurements to a volumetric measurement. The approach uses a high speed camera to acquire GSA images by scanning multiple planes in a volume of the flow field within a short period of time and obtain particle size distribution and velocity measurements in the entire volume.

  11. Winter precipitation particle size distribution measurement by Multi-Angle Snowflake Camera

    Science.gov (United States)

    Huang, Gwo-Jong; Kleinkort, Cameron; Bringi, V. N.; Notaroš, Branislav M.

    2017-12-01

    From the radar meteorology viewpoint, the most important properties for quantitative precipitation estimation of winter events are 3D shape, size, and mass of precipitation particles, as well as the particle size distribution (PSD). In order to measure these properties precisely, optical instruments may be the best choice. The Multi-Angle Snowflake Camera (MASC) is a relatively new instrument equipped with three high-resolution cameras to capture the winter precipitation particle images from three non-parallel angles, in addition to measuring the particle fall speed using two pairs of infrared motion sensors. However, the results from the MASC so far are usually presented as monthly or seasonally, and particle sizes are given as histograms, no previous studies have used the MASC for a single storm study, and no researchers use MASC to measure the PSD. We propose the methodology for obtaining the winter precipitation PSD measured by the MASC, and present and discuss the development, implementation, and application of the new technique for PSD computation based on MASC images. Overall, this is the first study of the MASC-based PSD. We present PSD MASC experiments and results for segments of two snow events to demonstrate the performance of our PSD algorithm. The results show that the self-consistency of the MASC measured single-camera PSDs is good. To cross-validate PSD measurements, we compare MASC mean PSD (averaged over three cameras) with the collocated 2D Video Disdrometer, and observe good agreements of the two sets of results.

  12. The field measurements of the activity-weighted size distributions of radon decay products

    International Nuclear Information System (INIS)

    Wasiolek, P.; Montassier, N.; Hopke, P.K.

    1991-01-01

    Because of the importance of particle size in the calculations of dose deposited in the respiratory tract by radon progeny, the determination of the size distribution of radon decay products in indoor air had increased in interest in recent years. A system for the measurement of the activity-weighted size distribution of radon decay products at environmental levels has been developed. The system (ASC-GSA) utilizes a combination of six multiple wire screens (Graded Screen Array) sampler detector units operated in parallel. The cut off points of the samplers and the data deconvolution procedure allow to obtain the activity fractions of radon progeny in the size range 0.5-500 mn. The computer control of sampling, alpha counting and data storage permits the operation of the system on the semi-continuous basis. The primary application of the ASC-GSA system has been to collect data of activity-weighted size distributions of radon progeny in real house environments. The results of field measurements in several houses with elevated radon levels are presented

  13. Soot particle size measurements in ethylene diffusion flames at elevated pressures

    KAUST Repository

    Steinmetz, Scott

    2016-05-07

    Soot particle size is investigated in laminar nitrogen-diluted ethylene coflow diffusion flames at 4, 8, 12 and 16 atm. Line of sight attenuation and scattering are used to measure two-dimensional soot volume fraction and particle size fields for the first time at elevated pressures. Soot volume fraction dependence on pressure is consistent with the observations of similar studies, scaling approximately with the square of pressure. Scattering intensity is analyzed through Rayleigh and Rayleigh-Debye-Gans polydisperse fractal aggregate theories to provide two estimates of particle size. An increase in overall particle sizes with pressure is found, consistent with similar one-dimensional studies. Particle diameters in the annulus of the flame increase faster with pressure than those on centerline. Contrary to previous studies, the dependence of particle size on pressure was found to taper off between 8 and 12 atm, with little observed growth beyond 12 atm. The measurements provide additional data for one of the International Sooting Flame (ISF) workshop\\'s target pressurized flames.

  14. Decomposition of Atmospheric Aerosol Phase Function by Particle Size and Morphology via Single Particle Scattering Measurements

    Science.gov (United States)

    Aptowicz, K. B.; Pan, Y.; Martin, S.; Fernandez, E.; Chang, R.; Pinnick, R. G.

    2013-12-01

    We report upon an experimental approach that provides insight into how particle size and shape affect the scattering phase function of atmospheric aerosol particles. Central to our approach is the design of an apparatus that measures the forward and backward scattering hemispheres (scattering patterns) of individual atmospheric aerosol particles in the coarse mode range. The size and shape of each particle is discerned from the corresponding scattering pattern. In particular, autocorrelation analysis is used to differentiate between spherical and non-spherical particles, the calculated asphericity factor is used to characterize the morphology of non-spherical particles, and the integrated irradiance is used for particle sizing. We found the fraction of spherical particles decays exponentially with particle size, decreasing from 11% for particles on the order of 1 micrometer to less than 1% for particles over 5 micrometer. The average phase functions of subpopulations of particles, grouped by size and morphology, are determined by averaging their corresponding scattering patterns. The phase functions of spherical and non-spherical atmospheric particles are shown to diverge with increasing size. In addition, the phase function of non-spherical particles is found to vary little as a function of the asphericity factor.

  15. Measuring the effectiveness of marketing activities use in relation to company size

    Directory of Open Access Journals (Sweden)

    Lucie Sychrová

    2013-01-01

    Full Text Available The aim of this paper is to research the relationship between measurements of effectiveness of marketing activities and company size. An analysis of the economic sources, professional publications, analysis and reports of previous research shows that the concept of measuring of effectiveness is one of the key themes, which economists always pay much attention. It is a criterion that helps to rationally decide on the use limited resources to meet the needs that are not limited. This topic deals with numerous domestic and foreign literatures. The authors are not only different concepts of effectiveness, but also the using terminology. There are multiple definitions of terms “effectiveness” For the same purpose and meaning. The same concept is often defined semantically different. Therefore, every company has a strong interest to be in all their activities more effectively than the competition. Logical response to changes and requirements of nowadays is using a combination of lot of methods to measure marketing effectiveness. Methods used for this article includes two phases. The first it was gained date by primary research, using a structure questionnaire and processed by statistical software SPSS. Research sample consists 115 companies operating in the Czech environment, which was chosen at random. There is investigated the correlation between measuring the effectiveness of marketing activities and company size. The second part investigated the dependence between the choice of metrics used to measure the effectiveness and company size. The results of the research showed that there is no correlation between measuring the effectiveness of marketing activities and company size. The value of Pearson Chi-Square test is greater than 0.05, it is 0.187. We can presume that dependency does not exist or it is small for these. Value of Symmetric measures is 0.432, which means that the intensity tends to be small rather than high.

  16. Detonation cell size measurements and predictions in hydrogen-air-steam mixtures at elevated temperatures

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsberg, T.; Boccio, J.; Economos, C.

    1994-01-01

    The present research reports on the effect of initial mixture temperature on the experimentally measured detonation cell size for hydrogen-air-steam mixtures. Experimental and theoretical research related to combustion phenomena in hydrogen-air-steam mixtures has been ongoing for many years. However, detonation cell size data currently exists or hydrogen-air-steam mixtures up to a temperature of only 400K. Sever accident scenarios have been identified for light water reactors (LWRs) where hydrogen-air mixture temperatures in excess of 400K could be generated within containment. The experiments in this report focus on extending the cell size data base for initial mixture temperatures in excess of 400K. The experiments were carried out in a 10-cm inner-diameter, 6.1-m long heated detonation tube with a maximum operating temperature of 700K and spatial temperature uniformity of ±14K. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air initial gas mixture temperature, in the range 300K--650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The hydrogen-air detonability limits for the 10-cm inside-diameter test vessel, based upon the onset of single-head spin, decreased from 15 percent by hydrogen at 300K down to about 9 percent hydrogen at 650K. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments

  17. Passive acoustic measurement of bedload grain size distribution using self-generated noise

    Directory of Open Access Journals (Sweden)

    T. Petrut

    2018-01-01

    Full Text Available Monitoring sediment transport processes in rivers is of particular interest to engineers and scientists to assess the stability of rivers and hydraulic structures. Various methods for sediment transport process description were proposed using conventional or surrogate measurement techniques. This paper addresses the topic of the passive acoustic monitoring of bedload transport in rivers and especially the estimation of the bedload grain size distribution from self-generated noise. It discusses the feasibility of linking the acoustic signal spectrum shape to bedload grain sizes involved in elastic impacts with the river bed treated as a massive slab. Bedload grain size distribution is estimated by a regularized algebraic inversion scheme fed with the power spectrum density of river noise estimated from one hydrophone. The inversion methodology relies upon a physical model that predicts the acoustic field generated by the collision between rigid bodies. Here we proposed an analytic model of the acoustic energy spectrum generated by the impacts between a sphere and a slab. The proposed model computes the power spectral density of bedload noise using a linear system of analytic energy spectra weighted by the grain size distribution. The algebraic system of equations is then solved by least square optimization and solution regularization methods. The result of inversion leads directly to the estimation of the bedload grain size distribution. The inversion method was applied to real acoustic data from passive acoustics experiments realized on the Isère River, in France. The inversion of in situ measured spectra reveals good estimations of grain size distribution, fairly close to what was estimated by physical sampling instruments. These results illustrate the potential of the hydrophone technique to be used as a standalone method that could ensure high spatial and temporal resolution measurements for sediment transport in rivers.

  18. Passive acoustic measurement of bedload grain size distribution using self-generated noise

    Science.gov (United States)

    Petrut, Teodor; Geay, Thomas; Gervaise, Cédric; Belleudy, Philippe; Zanker, Sebastien

    2018-01-01

    Monitoring sediment transport processes in rivers is of particular interest to engineers and scientists to assess the stability of rivers and hydraulic structures. Various methods for sediment transport process description were proposed using conventional or surrogate measurement techniques. This paper addresses the topic of the passive acoustic monitoring of bedload transport in rivers and especially the estimation of the bedload grain size distribution from self-generated noise. It discusses the feasibility of linking the acoustic signal spectrum shape to bedload grain sizes involved in elastic impacts with the river bed treated as a massive slab. Bedload grain size distribution is estimated by a regularized algebraic inversion scheme fed with the power spectrum density of river noise estimated from one hydrophone. The inversion methodology relies upon a physical model that predicts the acoustic field generated by the collision between rigid bodies. Here we proposed an analytic model of the acoustic energy spectrum generated by the impacts between a sphere and a slab. The proposed model computes the power spectral density of bedload noise using a linear system of analytic energy spectra weighted by the grain size distribution. The algebraic system of equations is then solved by least square optimization and solution regularization methods. The result of inversion leads directly to the estimation of the bedload grain size distribution. The inversion method was applied to real acoustic data from passive acoustics experiments realized on the Isère River, in France. The inversion of in situ measured spectra reveals good estimations of grain size distribution, fairly close to what was estimated by physical sampling instruments. These results illustrate the potential of the hydrophone technique to be used as a standalone method that could ensure high spatial and temporal resolution measurements for sediment transport in rivers.

  19. When Theory Meets Data: Comparing Model Predictions Of Hillslope Sediment Size With Field Measurements.

    Science.gov (United States)

    Mahmoudi, M.; Sklar, L. S.; Leclere, S.; Davis, J. D.; Stine, A.

    2017-12-01

    The size distributions of sediment produced on hillslopes and supplied to river channels influence a wide range of fluvial processes, from bedrock river incision to the creation of aquatic habitats. However, the factors that control hillslope sediment size are poorly understood, limiting our ability to predict sediment size and model the evolution of sediment size distributions across landscapes. Recently separate field and theoretical investigations have begun to address this knowledge gap. Here we compare the predictions of several emerging modeling approaches to landscapes where high quality field data are available. Our goals are to explore the sensitivity and applicability of the theoretical models in each field context, and ultimately to provide a foundation for incorporating hillslope sediment size into models of landscape evolution. The field data include published measurements of hillslope sediment size from the Kohala peninsula on the island of Hawaii and tributaries to the Feather River in the northern Sierra Nevada mountains of California, and an unpublished data set from the Inyo Creek catchment of the southern Sierra Nevada. These data are compared to predictions adapted from recently published modeling approaches that include elements of topography, geology, structure, climate and erosion rate. Predictive models for each site are built in ArcGIS using field condition datasets: DEM topography (slope, aspect, curvature), bedrock geology (lithology, mineralogy), structure (fault location, fracture density), climate data (mean annual precipitation and temperature), and estimates of erosion rates. Preliminary analysis suggests that models may be finely tuned to the calibration sites, particularly when field conditions most closely satisfy model assumptions, leading to unrealistic predictions from extrapolation. We suggest a path forward for developing a computationally tractable method for incorporating spatial variation in production of hillslope

  20. Approach for measuring the chemistry of individual particles in the size range critical for cloud formation.

    Science.gov (United States)

    Zauscher, Melanie D; Moore, Meagan J K; Lewis, Gregory S; Hering, Susanne V; Prather, Kimberly A

    2011-03-15

    Aerosol particles, especially those ranging from 50 to 200 nm, strongly impact climate by serving as nuclei upon which water condenses and cloud droplets form. However, the small number of analytical methods capable of measuring the composition of particles in this size range, particularly at the individual particle level, has limited our knowledge of cloud condensation nuclei (CCN) composition and hence our understanding of aerosols effect on climate. To obtain more insight into particles in this size range, we developed a method which couples a growth tube (GT) to an ultrafine aerosol time-of-flight mass spectrometer (UF-ATOFMS), a combination that allows in situ measurements of the composition of individual particles as small as 38 nm. The growth tube uses water to grow particles to larger sizes so they can be optically detected by the UF-ATOFMS, extending the size range to below 100 nm with no discernible changes in particle composition. To gain further insight into the temporal variability of aerosol chemistry and sources, the GT-UF-ATOFMS was used for online continuous measurements over a period of 3 days.

  1. An inverse modeling procedure to determine particle growth and nucleation rates from measured aerosol size distributions

    Directory of Open Access Journals (Sweden)

    B. Verheggen

    2006-01-01

    Full Text Available Classical nucleation theory is unable to explain the ubiquity of nucleation events observed in the atmosphere. This shows a need for an empirical determination of the nucleation rate. Here we present a novel inverse modeling procedure to determine particle nucleation and growth rates based on consecutive measurements of the aerosol size distribution. The particle growth rate is determined by regression analysis of the measured change in the aerosol size distribution over time, taking into account the effects of processes such as coagulation, deposition and/or dilution. This allows the growth rate to be determined with a higher time-resolution than can be deduced from inspecting contour plots ('banana-plots''. Knowing the growth rate as a function of time enables the evaluation of the time of nucleation of measured particles of a certain size. The nucleation rate is then obtained by integrating the particle losses from time of measurement to time of nucleation. The regression analysis can also be used to determine or verify the optimum value of other parameters of interest, such as the wall loss or coagulation rate constants. As an example, the method is applied to smog chamber measurements. This program offers a powerful interpretive tool to study empirical aerosol population dynamics in general, and nucleation and growth in particular.

  2. Submicron-sized aerosol and radon progeny measurements in an uranium mine

    International Nuclear Information System (INIS)

    Boulaud, D.; Chouard, J.C.

    1992-01-01

    Submicron-sized aerosol was studied in an uranium mine using an Electrical Aerosol Analyzer and a Differential Mobility Particle Sizer. In addition radon progeny particle size distributions were measured using a prototype instrument developed by us (SDI 2000). With cascade impactor the number weighted mean electrical mobility diameters and the geometric standard deviations ranged respectively from 0.05 to 0.1 μm and 1.8 to 2. The gross alpha activity weighted mean thermodynamic diameters ranged typically from 0.1 to 0.2 μm. 6 refs., 3 figs

  3. Correcting for particle size effects on plasma actuator particle image velocimetry measurements

    Science.gov (United States)

    Masati, A.; Sedwick, R. J.

    2018-01-01

    Particle image velocimetry (PIV) is often used to characterize plasma actuator flow, but particle charging effects are rarely taken into account. A parametric study was conducted to determine the effects of particle size on the velocity results of plasma actuator PIV experiments. Results showed that smaller particles more closely match air flow velocities than larger particles. The measurement uncertainty was quantified by deconvolving the particle image diameter from the correlation diameter. The true air velocity was calculated by linearly extrapolating to the zero-size particle diameter.

  4. Measurement of particle size distribution and mass concentration of nuclear fuel aerosols

    International Nuclear Information System (INIS)

    Pickering, S.

    1982-01-01

    The particle size distribution and particle mass concentration of a nuclear fuel aerosol is measured by admitting the aerosol into a vertically-extending container, positioning an alpha particle detector within the container so that its window is horizontal and directed vertically, stopping the admission of aerosol into the container, detecting the alpha-activity of the particles of the aerosol sedimenting onto the detector window (for example in a series of equal time intervals until a constant level is reached), and converting the alpha-activity measurements into particle size distribution and/or particle mass concentration measurements. The detector is attached to a pivotted arm and by raising a counterweight can be lowered from the container for cleaning. (author)

  5. Role of specimen size upon the measured toughness of cellular solids

    International Nuclear Information System (INIS)

    Christodoulou, I; Tan, P J

    2013-01-01

    It is well known that the mechanical properties of cellular solids depend critically upon the specimen size and that a 'sufficiently' large test specimen is needed to obtain representative bulk values. Notwithstanding, the fracture toughness of cellular solids is still measured experimentally based on standards, such as the ASTM E399 and E813, developed for solid materials that do not possess an intermediate, 'cell-level' length scale. Experimental data in the literature appears to show that the toughness of stochastic 3D foams is, also, size-dependent. This paper presents the results of a detailed finite element (FE) study that will quantify, and identify the physical origin of, the size-dependent effect. Three-point bending of a single-edge notched (or SEN(B)) specimen, with a 2D Voronoi micro-architecture, is modelled numerically to obtain estimates of fracture toughness which are compared to those obtained with a 'boundary-layer' analysis

  6. Influence of measuring temperature in size dependence of coercivity in nanostructured alloys

    International Nuclear Information System (INIS)

    Lopez, M.; Marin, P.; Kulik, T.; Hernando, A.

    2005-01-01

    An increase of coercive field with decreasing particle size has been observed in ball milled nanocomposite of Fe-rich nanocrystals embedded in an amorphous matrix. Previous works (J. Appl. Phys. 64 (1998) 6044) have concluded that for high lattice strain, , the increase of coercivity is due to the magnetoelastic anisotropy generated by . Even though other effects can also be involved, the experimental results seem to indicate that the influence of the particle size on the average structural anisotropy noticeably contributes to the hardening observed for low . The influence of measuring temperature in size dependence of coercivity in nanostructured alloys has been analyzed. Some analogies and differences in respect of that observed in partially nanocrystallized samples have been found

  7. Drop size measurements and entrainment in APR1400 during LBLOCA reflood phase

    International Nuclear Information System (INIS)

    Lee, Eo Hwak

    2010-02-01

    A study has been performed to investigate droplet size in the nuclear reactor of APR1400 during LBLOCA reflood phase and to develop droplet entrainment and deposition models for SPACE (Safety and Performance CodE) which is a safety analysis tool for PWR being developed in Korea. A freezing technique for measuring the size of droplets was developed to obtain the droplet size distribution in horizontal annular flow in a pipe with a 37.1 mm diameter. Droplets are frozen by using an extremely low temperature nitrogen gas with liquid film extraction. They are then photographed with a microscope and a CCD camera and measured by means of an image process. The results are compared with various experimental data. The droplet sizes measured by the freezing technique are comparable with those measured by other methods at a high superficial air velocity (of 50 m/s). However, because of the film extraction problem, the droplet sizes measured at a low superficial air velocity of less than 40 m/s are higher than those measured by other methods. A present method suggested for predicting the Sauter mean diameter is based on the maximum droplet size correlation for the experimental data, with and without liquid film extraction. The average droplet size is remarkably smaller downstream of the liquid film extractor because large droplets from the liquid film are excluded. In order to understand and to predict a heat transfer between superheated steam and droplets properly during reflood phase of LBLOCA, it is very important to measure broken droplet sizes by spacer grids. A study, therefore, has been performed to investigate droplet size in rod bundles with spacer grids and to develop a spacer grid droplet breakup model for safety analysis codes. Experiments were conducted with liquid droplets (SMD of 300∼700 μm) and various spacer grids at superficial air velocity of 10 m/s and 20 m/s based on FLECHT SEASET. The test channel and the grids were heated to 150 .deg. C to prevent

  8. Drop size measurements and entrainment in APR1400 during LBLOCA reflood phase

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eo Hwak

    2010-02-15

    A study has been performed to investigate droplet size in the nuclear reactor of APR1400 during LBLOCA reflood phase and to develop droplet entrainment and deposition models for SPACE (Safety and Performance CodE) which is a safety analysis tool for PWR being developed in Korea. A freezing technique for measuring the size of droplets was developed to obtain the droplet size distribution in horizontal annular flow in a pipe with a 37.1 mm diameter. Droplets are frozen by using an extremely low temperature nitrogen gas with liquid film extraction. They are then photographed with a microscope and a CCD camera and measured by means of an image process. The results are compared with various experimental data. The droplet sizes measured by the freezing technique are comparable with those measured by other methods at a high superficial air velocity (of 50 m/s). However, because of the film extraction problem, the droplet sizes measured at a low superficial air velocity of less than 40 m/s are higher than those measured by other methods. A present method suggested for predicting the Sauter mean diameter is based on the maximum droplet size correlation for the experimental data, with and without liquid film extraction. The average droplet size is remarkably smaller downstream of the liquid film extractor because large droplets from the liquid film are excluded. In order to understand and to predict a heat transfer between superheated steam and droplets properly during reflood phase of LBLOCA, it is very important to measure broken droplet sizes by spacer grids. A study, therefore, has been performed to investigate droplet size in rod bundles with spacer grids and to develop a spacer grid droplet breakup model for safety analysis codes. Experiments were conducted with liquid droplets (SMD of 300∼700 μm) and various spacer grids at superficial air velocity of 10 m/s and 20 m/s based on FLECHT SEASET. The test channel and the grids were heated to 150 .deg. C to prevent

  9. Measurement of an electron-beam size with a beam profile monitor using Fresnel zone plates

    International Nuclear Information System (INIS)

    Iida, K.; Nakamura, N.; Sakai, H.; Shinoe, K.; Takaki, H.; Fujisawa, M.; Hayano, H.; Nomura, M.; Kamiya, Y.; Koseki, T.; Amemiya, Y.; Aoki, N.; Nakayama, K.

    2003-01-01

    We present a non-destructive and real-time beam profile monitor using Fresnel zone plates (FZPs) and the measurement of an electron-beam size with this monitor in the KEK-Accelerator Test Facility (ATF) damping ring. The monitor system has the structure of a long-distance X-ray microscope, where two FZPs constitute an X-ray imaging optics. The synchrotron radiation from the electron beam at the bending magnet is monochromatized by a crystal monochromator and the transverse electron beam image is twenty times magnified by the two FZPs and detected on an X-ray CCD camera. The expected spatial resolution for the selected photon energy of 3.235 keV is sufficiently high to measure the horizontal and vertical beam sizes of the ATF damping ring. With the beam profile monitor, we succeeded in obtaining a clear electron-beam image and measuring the extremely small beam size less than 10 μm. The measured magnification of the X-ray imaging optics in the monitor system was in good agreement with the design value

  10. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    Science.gov (United States)

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Optimizing the calculation of point source count-centroid in pixel size measurement

    International Nuclear Information System (INIS)

    Zhou Luyi; Kuang Anren; Su Xianyu

    2004-01-01

    Pixel size is an important parameter of gamma camera and SPECT. A number of methods are used for its accurate measurement. In the original count-centroid method, where the image of a point source (PS) is acquired and its count-centroid calculated to represent PS position in the image, background counts are inevitable. Thus the measured count-centroid (X m ) is an approximation of the true count-centroid (X p ) of the PS, i.e. X m =X p + (X b -X p )/(1+R p /R b ), where Rp is the net counting rate of the PS, X b the background count-centroid and Rb the background counting. To get accurate measurement, R p must be very big, which is unpractical, resulting in the variation of measured pixel size. R p -independent calculation of PS count-centroid is desired. Methods: The proposed method attempted to eliminate the effect of the term (X b -X p )/(1 + R p /R b ) by bringing X b closer to X p and by reducing R b . In the acquired PS image, a circular ROI was generated to enclose the PS, the pixel with the maximum count being the center of the ROI. To choose the diameter (D) of the ROI, a Gaussian count distribution was assumed for the PS, accordingly, K=1-(0.5) D/R percent of the total PS counts was in the ROI, R being the full width at half maximum of the PS count distribution. D was set to be 6*R to enclose most (K=98.4%) of the PS counts. The count-centroid of the ROI was calculated to represent X p . The proposed method was tested in measuring the pixel size of a well-tuned SPECT, whose pixel size was estimated to be 3.02 mm according to its mechanical and electronic setting (128 x 128 matrix, 387 mm UFOV, ZOOM=1). For comparison, the original method, which was use in the former versions of some commercial SPECT software, was also tested. 12 PSs were prepared and their image acquired and stored. The net counting rate of the PSs increased from 10 cps to 1183 cps. Results: Using the proposed method, the measured pixel size (in mm) varied only between 3.00 and 3.01 (mean

  12. Optimizing the calculation of point source count-centroid in pixel size measurement

    International Nuclear Information System (INIS)

    Zhou Luyi; Kuang Anren; Su Xianyu

    2004-01-01

    Purpose: Pixel size is an important parameter of gamma camera and SPECT. A number of Methods are used for its accurate measurement. In the original count-centroid method, where the image of a point source(PS) is acquired and its count-centroid calculated to represent PS position in the image, background counts are inevitable. Thus the measured count-centroid (Xm) is an approximation of the true count-centroid (Xp) of the PS, i.e. Xm=Xp+(Xb-Xp)/(1+Rp/Rb), where Rp is the net counting rate of the PS, Xb the background count-centroid and Rb the background counting rate. To get accurate measurement, Rp must be very big, which is unpractical, resulting in the variation of measured pixel size. Rp-independent calculation of PS count-centroid is desired. Methods: The proposed method attempted to eliminate the effect of the term (Xb-Xp)/(1+Rp/Rb) by bringing Xb closer to Xp and by reducing Rb. In the acquired PS image, a circular ROI was generated to enclose the PS, the pixel with the maximum count being the center of the ROI. To choose the diameter (D) of the ROI, a Gaussian count distribution was assumed for the PS, accordingly, K=I-(0.5)D/R percent of the total PS counts was in the ROI, R being the full width at half maximum of the PS count distribution. D was set to be 6*R to enclose most (K=98.4%) of the PS counts. The count-centroid of the ROI was calculated to represent Xp. The proposed method was tested in measuring the pixel size of a well-tuned SPECT, whose pixel size was estimated to be 3.02 mm according to its mechanical and electronic setting (128*128 matrix, 387 mm UFOV, ZOOM=1). For comparison, the original method, which was use in the former versions of some commercial SPECT software, was also tested. 12 PSs were prepared and their image acquired and stored. The net counting rate of the PSs increased from 10cps to 1183cps. Results: Using the proposed method, the measured pixel size (in mm) varied only between 3.00 and 3.01( mean= 3.01±0.00) as Rp increased

  13. Retrieval of snow albedo and grain size using reflectance measurements in Himalayan basin

    Directory of Open Access Journals (Sweden)

    H. S. Negi

    2011-03-01

    Full Text Available In the present paper, spectral reflectance measurements of Himalayan seasonal snow were carried out and analysed to retrieve the snow albedo and effective grain size. The asymptotic radiative transfer (ART theory was applied to retrieve the plane and spherical albedo. The retrieved plane albedo was compared with the measured spectral albedo and a good agreement was observed with ±10% differences. Retrieved integrated albedo was found within ±6% difference with ground observed broadband albedo. The retrieved snow grain sizes using different models based on the ART theory were compared for various snow types and it was observed that the grain size model using two channel method (one in visible and another in NIR region can work well for the Himalayan seasonal snow and it was found consistent with temporal changes in grain size. This method can work very well for clean, dry snow as in the upper Himalaya, but sometimes, due to the low reflectances (<20% using wavelength 1.24 μm, the ART theory cannot be applied, which is common in lower and middle Himalayan old snow. This study is important for monitoring the Himalayan cryosphere using air-borne or space-borne sensors.

  14. Particle Sampling and Real Time Size Distribution Measurement in H2/O2/TEOS Diffusion Flame

    International Nuclear Information System (INIS)

    Ahn, K.H.; Jung, C.H.; Choi, M.; Lee, J.S.

    2001-01-01

    Growth characteristics of silica particles have been studied experimentally using in situ particle sampling technique from H 2 /O 2 /Tetraethylorthosilicate (TEOS) diffusion flame with carefully devised sampling probe. The particle morphology and the size comparisons are made between the particles sampled by the local thermophoretic method from the inside of the flame and by the electrostatic collector sampling method after the dilution sampling probe. The Transmission Electron Microscope (TEM) image processed data of these two sampling techniques are compared with Scanning Mobility Particle Sizer (SMPS) measurement. TEM image analysis of two sampling methods showed a good agreement with SMPS measurement. The effects of flame conditions and TEOS flow rates on silica particle size distributions are also investigated using the new particle dilution sampling probe. It is found that the particle size distribution characteristics and morphology are mostly governed by the coagulation process and sintering process in the flame. As the flame temperature increases, the effect of coalescence or sintering becomes an important particle growth mechanism which reduces the coagulation process. However, if the flame temperature is not high enough to sinter the aggregated particles then the coagulation process is a dominant particle growth mechanism. In a certain flame condition a secondary particle formation is observed which results in a bimodal particle size distribution

  15. Tumour size measurement in a mouse model using high resolution MRI

    International Nuclear Information System (INIS)

    Montelius, Mikael; Ljungberg, Maria; Horn, Michael; Forssell-Aronsson, Eva

    2012-01-01

    Animal models are frequently used to assess new treatment methods in cancer research. MRI offers a non-invasive in vivo monitoring of tumour tissue and thus allows longitudinal measurements of treatment effects, without the need for large cohorts of animals. Tumour size is an important biomarker of the disease development, but to our knowledge, MRI based size measurements have not yet been verified for small tumours (10 −2 –10 −1 g). The aim of this study was to assess the accuracy of MRI based tumour size measurements of small tumours on mice. 2D and 3D T2-weighted RARE images of tumour bearing mice were acquired in vivo using a 7 T dedicated animal MR system. For the 3D images the acquired image resolution was varied. The images were exported to a PC workstation where the tumour mass was determined assuming a density of 1 g/cm 3 , using an in-house developed tool for segmentation and delineation. The resulting data were compared to the weight of the resected tumours after sacrifice of the animal using regression analysis. Strong correlations were demonstrated between MRI- and necropsy determined masses. In general, 3D acquisition was not a prerequisite for high accuracy. However, it was slightly more accurate than 2D when small (<0.2 g) tumours were assessed for inter- and intraobserver variation. In 3D images, the voxel sizes could be increased from 160 3 μm 3 to 240 3 μm 3 without affecting the results significantly, thus reducing acquisition time substantially. 2D MRI was sufficient for accurate tumour size measurement, except for small tumours (<0.2 g) where 3D acquisition was necessary to reduce interobserver variation. Acquisition times between 15 and 50 minutes, depending on tumour size, were sufficient for accurate tumour volume measurement. Hence, it is possible to include further MR investigations of the tumour, such as tissue perfusion, diffusion or metabolic composition in the same MR session

  16. Atmospheric particles acting as ice forming nuclei in different size ranges and cloud condensation nuclei measurements

    International Nuclear Information System (INIS)

    Santachiara, G.; Di Matteo, L.; Belosi, F.; Prodi, F.

    2009-01-01

    Measurements of ice nuclei (I N) in different size classes of aerosol P M1, P M2.5, PM10, and total suspended particles (Tsp) were performed at a rural site (S.Pietro Capofiume, in the Po Valley, Italy). Simultaneous measurements of particle number concentrations were also made with a condensation nucleus counter (CN C-TSI), along with particle concentration in different size classes starting from diameter d > 0.3 μm (Optical Spectrometer Grimm, Mod.1.108). No correlation is observed between I N and the particle number concentration measured with the condensation nuclei counter, and there is only a weak correlation with the particle concentration measured using the optical counter, thus confirming the contribution of the accumulation and coarse aerosol fraction. A positive correlation is observed between supersaturation with respect to ice and water values and ice nuclei number concentration, and an exponential dependence of I N on temperature is found. In addition, cloud concentration nuclei (C CN) were measured. The present measurements reveal a diurnal trend, with lower values at about midday and higher ones during the night, a similar trend between C CN and the relative humidity, and opposite to the mixing layer height.

  17. Size, velocity, and concentration in suspension measurements of spherical droplets and cylindrical jets.

    Science.gov (United States)

    Onofri, F; Bergougnoux, L; Firpo, J L; Misguich-Ripault, J

    1999-07-20

    The principle of an optical technique for simultaneous velocity, size, and concentration in suspension measurements of spherical droplets and cylindrical jets is proposed. This technique is based on phase Doppler anemometry working in the dual burst technique configuration. The particle size and velocity are deduced from the reflected signal phase and frequency, whereas the amplitude ratio between the refracted and the reflected signals is used for measuring the concentration of small scatterers inside the particles. Numerical simulations, based on geometrical optics and a Monte Carlo model, and an experimental validation test on cylindrical jets made of various suspensions, are used to validate the principle of the proposed technique. It is believed that this new technique could be useful in investigating processes in which liquid suspensions are sprayed for surface coating, drying, or combustion applications.

  18. Size of nuclear sources from measurements of proton-proton correlations at small relative momentum

    International Nuclear Information System (INIS)

    Rebreyend, D.; Kox, S.; Merchez, F.; Noren, B.; Perrin, C.; Khelfaoui, B.; Gondrand, J.C.; Bondorf, J.P.

    1990-01-01

    This contribution will present recent measurements performed on light heavy ion reactions at intermediate energies. Nuclear source sizes were determined by measuring the correlation at small relative momentum, between two protons detected in the EMRIC set-up. This technique allows the determination of the extent of the emitting source by constructing a correlation function for the coincident protons and analyzing it in the framework of a final state interaction model. We found the apparent source size to be large compared to the dimension of the studied system and low sensitivity of the extracted radii as a function of the target mass and detection angle. We will show that simulations may be needed to fully estimate the correlation induced by detectors with small angular acceptance

  19. Sizes of water-soluble luminescent quantum dots measured by fluorescence correlation spectroscopy

    International Nuclear Information System (INIS)

    Zhang Pudun; Li Liang; Dong Chaoqing; Qian Huifeng; Ren Jicun

    2005-01-01

    In this paper, fluorescence correlation spectroscopy (FCS) was applied to measure the size of water-soluble quantum dots (QDs). The measurements were performed on a home-built FCS system based on the Stokes-Einstein equation. The obtained results showed that for bare CdTe QDs the sizes from FCS were larger than the ones from transmission electron microscopy (TEM). The brightness of QDs was also evaluated using FCS technique. It was found that the stability of the surface chemistry of QDs would be significantly improved by capping it with hard-core shell. Our data demonstrated that FCS is a simple, fast, and effective method for characterizing the fluorescent quantum dots, and is especially suitable for determining the fluorescent nanoparticles less than 10 nm in water solution

  20. Is radiographic measurement of bony landmarks reliable for lateral meniscal sizing?

    Science.gov (United States)

    Yoon, Jung-Ro; Kim, Taik-Seon; Lim, Hong-Chul; Lim, Hyung-Tae; Yang, Jae-Hyuk

    2011-03-01

    radiologic measurement showed good reliability (intraclass correlation coefficients, .823 to .973). The authors tried to determine the best-fit equation for predicting meniscal size from Pollard's method of bone size, as follows: anatomic length = 0.52 × plateau length (according to Pollard's method) + 5.2, not as Pollard suggested (0.7 × Pollard's plateau length). Based on this equation-namely, the modified Pollard method-the percentage difference decreased, and the accuracy increased to 92%. Lateral meniscal length dimension can be accurately predicted from the authors' radiographic tibial plateau measurements. This study may provide valuable information in preoperative sizing of lateral meniscus in meniscal allograft transplantation.

  1. Big hearts, small hands: a focus group study exploring parental food portion behaviours

    OpenAIRE

    Curtis, Kristina; Atkins, Louise; Brown, Katherine

    2017-01-01

    Abstract Background The development of healthy food portion sizes among families is deemed critical to childhood weight management; yet little is known about the interacting factors influencing parents’ portion control behaviours. This study aimed to use two synergistic theoretical models of behaviour: the COM-B model (Capability, Opportunity, Motivation – Behaviour) and Theoretical Domains Framework (TDF) to identify a broad spectrum of theoretically derived influences on parents’ portion co...

  2. Measurement of activity-weighted size distributions of radon decay products in a normally occupied home

    International Nuclear Information System (INIS)

    Hopke, P.K.; Wasiolek, P.; Montassier, N.; Cavallo, A.; Gadsby, K.; Socolow, R.

    1992-01-01

    In order to assess the exposure of individuals to the presence of indoor radioactivity arising from the decay of radon, an automated, semicontinuous graded screen array system was developed to permit the measurement of the activity-weighted size distributions of the radon progeny in homes. The system has been modified so that the electronics and sampling heads can be separated from the pump by approximately 15 m. The system was placed in the living room of a one-storey house with basement in Princeton, NJ and operated for 2 weeks while the house was occupied by the home owners in their normal manner. One of the house occupants was a cigarette smoker. Radon and potential alpha energy concentration (PAEC) measurements were also made, but condensation nuclei counts were not performed. PAEC values ranged from 23.4 to 461.6 mWL. In the measured activity size distributions, the amount of activity in the 0.5-1.5 nm size range can be considered to be the unattached fraction. The mean value for the 218 Po unattached fraction is 0.217 with a range of 0.054-0.549. The median value for the unattached fraction of PAEC is 0.077 with a range of 0.022-0.178. (author)

  3. IN SITU MEASUREMENTS OF THE SIZE AND DENSITY OF TITAN AEROSOL ANALOGS

    Energy Technology Data Exchange (ETDEWEB)

    Hoerst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2013-06-10

    The organic haze produced from complex CH{sub 4}/N{sub 2} chemistry in the atmosphere of Titan plays an important role in processes that occur in the atmosphere and on its surface. The haze particles act as condensation nuclei and are therefore involved in Titan's methane hydrological cycle. They also may behave like sediment on Titan's surface and participate in both fluvial and aeolian processes. Models that seek to understand these processes require information about the physical properties of the particles including their size and density. Although measurements obtained by Cassini-Huygens have placed constraints on the size of the haze particles, their densities remain unknown. We have conducted a series of Titan atmosphere simulation experiments and measured the size, number density, and particle density of Titan aerosol analogs, or tholins, for CH{sub 4} concentrations from 0.01% to 10% using two different energy sources, spark discharge and UV. We find that the densities currently in use by many Titan models are higher than the measured densities of our tholins.

  4. Measurement of void fraction and bubble size distribution in two-phase flow system

    International Nuclear Information System (INIS)

    Huahun, G.

    1987-01-01

    The importance of study two phase flow parameter and microstructure has appeared increasingly, with the development of two-phase flow discipline. In the paper, the measurement methods of several important microstructure parameter in a two phase flow vertical channel have been studied. Using conductance probe the two phase flow pattern and the average void fraction have been measured previously by the authors. This paper concerns microstructure of the bubble size distribution and local void fraction. The authors studied the methods of measuring bubble velocity, size distribution and local void fraction using double conductance probes and a set of apparatus. Based on our experiments and Yoshihiro work, a formula of calculated local void fraction has been deduced by using the statistical characteristics of bubbles in two phase flow and the relation between calculated bubble size and voltage has been determined. Finally the authors checked by using photograph and fast valve, which is classical but reliable. The results are the same with what has been studied before

  5. IN SITU MEASUREMENTS OF THE SIZE AND DENSITY OF TITAN AEROSOL ANALOGS

    International Nuclear Information System (INIS)

    Hörst, S. M.; Tolbert, M. A

    2013-01-01

    The organic haze produced from complex CH 4 /N 2 chemistry in the atmosphere of Titan plays an important role in processes that occur in the atmosphere and on its surface. The haze particles act as condensation nuclei and are therefore involved in Titan's methane hydrological cycle. They also may behave like sediment on Titan's surface and participate in both fluvial and aeolian processes. Models that seek to understand these processes require information about the physical properties of the particles including their size and density. Although measurements obtained by Cassini-Huygens have placed constraints on the size of the haze particles, their densities remain unknown. We have conducted a series of Titan atmosphere simulation experiments and measured the size, number density, and particle density of Titan aerosol analogs, or tholins, for CH 4 concentrations from 0.01% to 10% using two different energy sources, spark discharge and UV. We find that the densities currently in use by many Titan models are higher than the measured densities of our tholins.

  6. Floc size distributions of suspended kaolinite in an advection transport dominated tank: measurements and modeling

    Science.gov (United States)

    Shen, Xiaoteng; Maa, Jerome P.-Y.

    2017-11-01

    In estuaries and coastal waters, floc size and its statistical distributions of cohesive sediments are of primary importance, due to their effects on the settling velocity and thus deposition rates of cohesive aggregates. The development of a robust flocculation model that includes the predictions of floc size distributions (FSDs), however, is still in a research stage. In this study, a one-dimensional longitudinal (1-DL) flocculation model along a streamtube is developed. This model is based on solving the population balance equation to find the FSDs by using the quadrature method of moments. To validate this model, a laboratory experiment is carried out to produce an advection transport-dominant environment in a cylindrical tank. The flow field is generated by a marine pump mounted at the bottom center, with its outlet facing upward. This setup generates an axially symmetric flow which is measured by an acoustic Doppler velocimeter (ADV). The measurement results provide the hydrodynamic input data required for this 1-DL model. The other measurement results, the FSDs, are acquired by using an automatic underwater camera system and the resulting images are analyzed to validate the predicted FSDs. This study shows that the FSDs as well as their representative sizes can be efficiently and reasonably simulated by this 1-DL model.

  7. The Influence of the Size, Age and Sex on the Computed Tomographic Measured Size of the Pituitary Gland in Normal Horses.

    Science.gov (United States)

    Crijns, C P; Van Bree, H J; Broeckx, B J G; Schauvliege, S; Van Loon, G; Martens, A; Vanderperren, K; Dingemanse, W B; Gielen, I M

    2017-06-01

    The objective of this study was to examine the influence of the size, age and sex of the horse on the size of the pituitary gland and determine the possibility of using the pituitary gland height-to-brain area ratio (P:B ratio) to allow comparison of different sized and aged horses. Thirty-two horses without pituitary pars inter-media dysfunction that underwent a contrast-enhanced computed tomographic (CT) examination were included in a cross-sectional study. On the CT images, the pituitary gland height was measured and the P:B ratio was calculated. These measurements were correlated to the size, age and sex of the horses. The pituitary gland height was significantly associated with the size (P horses. No significant association was found between the P:B ratio and the size (P = 0.25), the age (P = 0.06) or the sex (P = 0.25) of the horses. In conclusion, the pituitary gland size varies between different sized and aged horses. The use of the P:B ratio is a valuable metric for making comparisons between the pituitary glands of these horses. © 2017 Blackwell Verlag GmbH.

  8. Sodium leakage and combustion tests. Measurement and distribution of droplet size using various spray nozzles

    International Nuclear Information System (INIS)

    Nagai, Keiichi; Hirabayashi, Masaru; Onojima, T.; Gunji, Minoru; Ara, Kuniaki; Oki, Yoshihisa

    1999-04-01

    In order to develop a numerical code simulating sodium fires initiated frame dispersion of droplets, measured data of droplet diameter as well as its distribution are needed. In the present experiment the distribution of droplet diameter was measured using water, oil and sodium. The tests elucidated the influential factors with respect to the droplet diameter. In addition, we sought to develop a similarity law between water and sodium. The droplet size distribution of sodium using the large diameter droplet (Elnozzle) was predicted. (J.P.N.)

  9. Verification measurements of the IRMM-1027 and the IAEA large-sized dried (LSD) spikes

    International Nuclear Information System (INIS)

    Jakopic, R.; Aregbe, Y.; Richter, S.

    2017-01-01

    In the frame of the accountancy measurements of the fissile materials, reliable determinations of the plutonium and uranium content in spent nuclear fuel are required to comply with international safeguards agreements. Large-sized dried (LSD) spikes of enriched "2"3"5U and "2"3"9Pu for isotope dilution mass spectrometry (IDMS) analysis are routinely applied in reprocessing plants for this purpose. A correct characterisation of these elements is a pre-requirement for achieving high accuracy in IDMS analyses. This paper will present the results of external verification measurements of such LSD spikes performed by the European Commission and the International Atomic Energy Agency. (author)

  10. Detailed measurements and modelling of thermo active components using a room size test facility

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Svendsen, Svend

    2005-01-01

    measurements in an office sized test facility with thermo active ceiling and floor as well as modelling of similar conditions in a computer program designed for analysis of building integrated heating and cooling systems. A method for characterizing the cooling capacity of thermo active components is described...... typically within 1-2K of the measured results. The simulation model, whose room model splits up the radiative and convective heat transfer between room and surfaces, can also be used to predict the dynamical conditions, where especially the temperature rise during the day is important for designing...

  11. Spatial distribution and size of small canopy gaps created by Japanese black bears: estimating gap size using dropped branch measurements.

    Science.gov (United States)

    Takahashi, Kazuaki; Takahashi, Kaori

    2013-06-10

    Japanese black bears, a large-bodied omnivore, frequently create small gaps in the tree crown during fruit foraging. However, there are no previous reports of black bear-created canopy gaps. To characterize physical canopy disturbance by black bears, we examined a number of parameters, including the species of trees in which canopy gaps were created, gap size, the horizontal and vertical distribution of gaps, and the size of branches broken to create gaps. The size of black bear-created canopy gaps was estimated using data from branches that had been broken and dropped on the ground. The disturbance regime was characterized by a highly biased distribution of small canopy gaps on ridges, a large total overall gap area, a wide range in gap height relative to canopy height, and diversity in gap size. Surprisingly, the annual rate of bear-created canopy gap formation reached 141.3 m2 ha-1 yr-1 on ridges, which were hot spots in terms of black bear activity. This rate was approximately 6.6 times that of tree-fall gap formation on ridges at this study site. Furthermore, this rate was approximately two to three times that of common tree-fall gap formation in Japanese forests, as reported in other studies. Our findings suggest that the ecological interaction between black bears and fruit-bearing trees may create a unique light regime, distinct from that created by tree falls, which increases the availability of light resources to plants below the canopy.

  12. Real-time measurements of suspended sediment concentration and particle size using five techniques

    Science.gov (United States)

    Felix, D.; Albayrak, I.; Abgottspon, A.; Boes, R. M.

    2016-11-01

    Fine sediments are important in the design and operation of hydropower plants (HPPs), in particular with respect to sediment management and hydro-abrasive erosion in hydraulic machines. Therefore, there is a need for reliable real-time measurements of suspended sediment mass concentration (SSC) and particle size distribution (PSD). The following instruments for SSC measurements were investigated in a field study during several years at the HPP Fieschertal in the Swiss Alps: (1) turbidimeters, (2) a Laser In-Situ Scattering and Trans- missometry instrument (LISST), (3) a Coriolis Flow and Density Meter (CFDM), (4) acoustic transducers, and (5) pressure sensors. LISST provided PSDs in addition to concentrations. Reference SSCs were obtained by gravimetrical analysis of automatically taken water samples. In contrast to widely used turbidimeters and the single-frequency acoustic method, SSCs obtained from LISST, the CFDM or the pressure sensors were less or not affected by particle size variations. The CFDM and the pressure sensors allowed measuring higher SSC than the optical or the acoustic techniques (without dilution). The CFDM and the pressure sensors were found to be suitable to measure SSC ≥ 2 g/l. In this paper, the measuring techniques, instruments, setup, methods for data treatment, and selected results are presented and discussed.

  13. Analysis of the Indentation Size Effect in the Microhardness Measurements in B6O

    Directory of Open Access Journals (Sweden)

    Ronald Machaka

    2011-01-01

    Full Text Available The Vickers microhardness measurements of boron suboxide (B6O ceramics prepared by uniaxial hot-pressing was investigated at indentation test loads in the range from 0.10 to 2.0 kgf. Results from the investigation indicate that the measured microhardness exhibits an indentation load dependence. Based on the results, we present a comprehensive model intercomparison study of indentation size effects (ISEs in the microhardness measurements of hot-pressed B6O discussed using existing models, that is, the classical Meyer's law, Li and Bradt's proportional specimen resistance model (PSR, the modified proportional specimen resistance model (MPSR, and Carpinteri's multifractal scaling law (MFSL. The best correlation between literature-cited load-independent Vickers microhardness values, the measured values, and applied models was achieved in the case of the MPSR and the MFSL models.

  14. Retrievals of Cloud Droplet Size from the RSP Data: Validation Using in Situ Measurements

    Science.gov (United States)

    Alexandrov, Mikhail D.; Cairns, Brian; Sinclair, Kenneth; Wasilewski, Andrzej P.; Ziemba, Luke; Crosbie, Ewan; Hair, John; Hu, Yongxiang; Hostetler, Chris; Stamnes, Snorre

    2016-01-01

    We present comparisons of cloud droplet size distributions retrieved from the Research Scanning Polarimeter (RSP) data with correlative in situ measurements made during the North Atlantic Aerosols and Marine Ecosystems Study (NAAMES). This field experiment was based at St. Johns airport, Newfoundland, Canada with the latest deployment in May - June 2016. RSP was onboard the NASA C-130 aircraft together with an array of in situ and other remote sensing instrumentation. The RSP is an along-track scanner measuring polarized and total reflectances in9 spectral channels. Its unique high angular resolution allows for characterization of liquid water droplet size using the rainbow structure observed in the polarized reflectances in the scattering angle range between 135 and 165 degrees. A parametric fitting algorithm applied to the polarized reflectances provides retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, Rainbow Fourier Transform (RFT), which allows us to retrieve the droplet size distribution (DSD) itself. The latter is important in the case of clouds with complex structure, which results in multi-modal DSDs. During NAAMES the aircraft performed a number of flight patterns specifically designed for comparison of remote sensing retrievals and in situ measurements. These patterns consisted of two flight segments above the same straight ground track. One of these segments was flown above clouds allowing for remote sensing measurements, while the other was at the cloud top where cloud droplets were sampled. We compare the DSDs retrieved from the RSP data with in situ measurements made by the Cloud Droplet Probe (CDP). The comparisons show generally good agreement with deviations explainable by the position of the aircraft within cloud and by presence of additional cloud layers in RSP view that do not contribute to the in situ DSDs. In the

  15. Which factors influence MRI-pathology concordance of tumour size measurements in breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Rominger, M.; Frauenfelder, T. [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Berg, D. [Urbankrankenhaus Berlin, Anesthesiology, Berlin (Germany); Ramaswamy, A. [University Hospital Marburg, Pathology, Marburg (Germany); Timmesfeld, N. [Philipps University Marburg, Institute for Medical Biometry and Epidemiology, Marburg (Germany)

    2016-05-15

    To assess MRI-pathology concordance and factors influencing tumour size measurement in breast cancer. MRI tumour size (greatest diameter in anatomical planes (MRI-In-Plane) and greatest diameter along main tumour axis (MRI-MPR)) of 115 consecutive breast lesions (59 invasive lobular carcinoma, 46 invasive ductal carcinoma, and 10 ductal carcinoma in situ) was retrospectively compared to size measured at histopathology (pT size (Path-TNM) and greatest tumour diameter as relevant for excision (Path-Diameter; reference standard)). Histopathological tumour types, preoperative palpability, surgical management, additional high-risk lesions, and BI-RADS lesion type (mass versus non-mass enhancements) were assessed as possible influencing factors. Systematic errors were most pronounced between MRI-MPR and Path-TNM (7.1 mm, limits of agreement (LoA) [-21.7; 35.9]), and were lowest between MRI-In-Plane and Path-Diameter (0.2 mm, LoA [-19.7; 20.1]). Concordance rate of MRI-In-Plane with Path-Diameter was 86 % (97/113), overestimation 9 % (10/113) and underestimation 5 % (6/113); BI-RADS mass lesions were overestimated in 7 % (6/81) versus 41 % (13/32) for non-mass enhancements. On multivariate analysis only BI-RADS lesion type significantly influenced MRI-pathology concordance (p < 0.001). 2/59 (3 %) ILC did not enhance. Concordance rate varies according to the execution of MRI and histopathological measurements. Beyond this only non-mass enhancement significantly predicted discordance. (orig.)

  16. New phase method of measuring particle size with laser Doppler radar

    Science.gov (United States)

    Zemlianskii, Vladimir M.

    1996-06-01

    A vast field of non-contact metrology, vibrometry, dynamics and microdynamics problems solved on the basis of laser Doppler method resulted in the development of great variety of laser Doppler radar (LDR). In coherent LDR few beams with various polarization are generally adopted, that are directed at the zone of measurement, through which the probing air stream moves. Studies of various coherent LDR demonstrated that polarization-phase effects of scattering can in some cases considerably effect on the signal-to-noise ratio of the Doppler signal. On the other side using phase effects can simultaneous measurement of size and velocity of spherical particles. New possibilities for improving the accuracy of measuring spherical particles' sizes come to light when application is made in coherent LDR of two waves- probing and one out of the types of symmetrical reception of scattered radiation, during which phase-conjugate signals are formed. The theoretical analysis on the basis of the scattering theory showed, that in symmetrical reception of scattered radiation with respect to the planes OXZ and OYZ output signal of the photoreceiver contains two high- frequency signal components, which in relation to parameters of the probing and size, can either be in phase or antiphase. Results of numerical modeling are presented: amplitude of high frequency signal, coefficient of phase and polarization matching of mixed waves, the depths of photocurrent modulation and also signal's phase in relation to the angle between the probing beams. Phase method of determining particle's sizes based on the use of two wavelengths probing and symmetrical reception of scattered radiation in which conditions for the formation of phase conjugated high-frequency signals are satisfied is presented.

  17. Measure of pore size in micro filtration polymeric membrane using ultrasonic technique and artificial neural networks

    International Nuclear Information System (INIS)

    Lucas, Carla de Souza

    2009-01-01

    This work presents a study of the pore size in micro filtration polymeric membranes, used in the nuclear area for the filtration of radioactive liquid effluent, in the residual water treatment of the petrochemical industry, in the electronic industry for the ultrapure water production for the manufacture of conductors and laundering of microcircuits and in many other processes of separation. Diverse processes for measures of pores sizes in membranes exist, amongst these, electronic microscopy, of bubble point and mercury intrusion porosimetry, however the majority of these uses destructive techniques, of high cost or great time of analysis. The proposal of this work is to measure so great of pore being used ultrasonic technique in the time domain of the frequency and artificial neural networks. A receiving/generator of ultrasonic pulses, a immersion transducer of 25 MHz was used, a tank of immersion and microporous membranes of pores sizes of 0,2 μm, 0,4 μm, 0,6 μm, 8 μm, 10 μm and 12 μm. The ultrasonic signals after to cover the membrane, come back to the transducer (emitting/receiving) bringing information of the interaction of the signal with the membranes. These signals had been used for the training of neural networks, and these had supplied the necessary precision the distinction of the same ones. Soon after, technique with the one of electronic microscopy of sweepings was made the comparison of this. The experiment showed very resulted next to the results gotten with the MEV, what it indicated that the studied technique is ideal for measure of pore size in membranes for being not destructive and of this form to be able to be used also on-line of production. (author)

  18. Estimating drizzle drop size and precipitation rate using two-colour lidar measurements

    Directory of Open Access Journals (Sweden)

    C. D. Westbrook

    2010-06-01

    Full Text Available A method to estimate the size and liquid water content of drizzle drops using lidar measurements at two wavelengths is described. The method exploits the differential absorption of infrared light by liquid water at 905 nm and 1.5 μm, which leads to a different backscatter cross section for water drops larger than ≈50 μm. The ratio of backscatter measured from drizzle samples below cloud base at these two wavelengths (the colour ratio provides a measure of the median volume drop diameter D0. This is a strong effect: for D0=200 μm, a colour ratio of ≈6 dB is predicted. Once D0 is known, the measured backscatter at 905 nm can be used to calculate the liquid water content (LWC and other moments of the drizzle drop distribution.

    The method is applied to observations of drizzle falling from stratocumulus and stratus clouds. High resolution (32 s, 36 m profiles of D0, LWC and precipitation rate R are derived. The main sources of error in the technique are the need to assume a value for the dispersion parameter μ in the drop size spectrum (leading to at most a 35% error in R and the influence of aerosol returns on the retrieval (≈10% error in R for the cases considered here. Radar reflectivities are also computed from the lidar data, and compared to independent measurements from a colocated cloud radar, offering independent validation of the derived drop size distributions.

  19. Concentration Measurements of Suspended Load using ADV with Influence of the Particle Size

    Science.gov (United States)

    Schwarzwälder, Kordula

    2017-04-01

    ADV backscatter data can be used under certain conditions to gain information about the concentrations of suspended loads. This was shown in many studies before (Fugate and Friedrichs 2002; Chanson et al 2008; Ha et al. 2009). This paper reports on a pre-study to investigate the influence of particle size on concentration measurements for suspended sediment load with ADV. The study was conducted in a flume in the Oskar-von-Miller-Institute using fresh water from a river including the natural suspended load. The ADV used in the experiments was a Vectrino Profiler (Nortek). In addition water samples were taken for TSS and TOC. For the measurements a surge was generated in the flume to ensure that also particles of larger size will be present in the water phase. The measurements and samples were taken during the whole surge event. Therefore we were able to find a good correlation between the backscatter data of the ADV and the TSS as well as TOC results. For the decreasing part of the flow event the concentration of TOC in the suspended load of the water phase is decreasing much slower than the TSS and results in a damped decrease of the backscatter values. This means that the results for concentration measurements might be slightly influenced by the size of the particles. Further evaluations of measurements conducted with a LISST SL (Sequoia) will be investigated to show the trend of the particle sizes during this process and fortify this result. David C. Fugate, Carl T. Friedrichs, Determining concentration and fall velocity of estuarine particle populations using ADV, OBS and LISST, Continental Shelf Research, Volume 22, Issues 11-13, 2002 H.K. Ha, W.-Y. Hsu, J.P.-Y. Maa, Y.Y. Shao, C.W. Holland, Using ADV backscatter strength for measuring suspended cohesive sediment concentration, Continental Shelf Research, Volume 29, Issue 10, 2009 Hubert Chanson, Maiko Takeuchi, Mark Trevethan, Using turbidity and acoustic backscatter intensity as surrogate measures of

  20. Size of lumbar disc hernias measured using computed tomography and related to sciatic symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Fagerlund, M.K.J.; Thelander, U.; Friberg, S. (Umeaa Univ. Hospital (Sweden). Dept. of Diagnostic Radiology Umeaa Univ. Hospital (Sweden). Dept. of Orthopedics)

    1990-11-01

    The change in the relative size of lumbar disc hernias and its relation to sciatic symptoms was investigated in 30 consecutive patients after conservative treatment of CT verified lumbar disc herniations. CT and clinical examination were performed before the start of therapy (CT1), as well as 3 months (CT2) and 24 months (CT3) after institution of treatment. In each patient the size of the lumbar disc herniation in relation to the size of the spinal canal was measured on identical CT slices and expressed as an index. The disc herniation index decreased markedly from CT1 to CT2 (p<0.001). Between CT2 and CT3 the reduction of the hernias was less pronounced and not significant for hernias located centrally but still significant for intermediate (p=0.03) and lateral (p=0.04) hernias. The degree of sciatic symptoms also decreased markedly between CT1 and CT2 (p=0.001) while no further improvement occurred from CT2 to CT3. There was a significant positive correlation between the improvement from sciatic pain and the reduction in the size of the individual hernia (CT1-CT2 p=0.02, CT2-CT3 p<0.001). Thus, the disc herniation index provided a method to study the anatomic effect of conservative treatment as well as a method to evaluate sciatic symptoms in relation to anatomic changes. (orig.).

  1. Size of lumbar disc hernias measured using computed tomography and related to sciatic symptoms

    International Nuclear Information System (INIS)

    Fagerlund, M.K.J.; Thelander, U.; Friberg, S.; Umeaa Univ. Hospital

    1990-01-01

    The change in the relative size of lumbar disc hernias and its relation to sciatic symptoms was investigated in 30 consecutive patients after conservative treatment of CT verified lumbar disc herniations. CT and clinical examination were performed before the start of therapy (CT1), as well as 3 months (CT2) and 24 months (CT3) after institution of treatment. In each patient the size of the lumbar disc herniation in relation to the size of the spinal canal was measured on identical CT slices and expressed as an index. The disc herniation index decreased markedly from CT1 to CT2 (p<0.001). Between CT2 and CT3 the reduction of the hernias was less pronounced and not significant for hernias located centrally but still significant for intermediate (p=0.03) and lateral (p=0.04) hernias. The degree of sciatic symptoms also decreased markedly between CT1 and CT2 (p=0.001) while no further improvement occurred from CT2 to CT3. There was a significant positive correlation between the improvement from sciatic pain and the reduction in the size of the individual hernia (CT1-CT2 p=0.02, CT2-CT3 p<0.001). Thus, the disc herniation index provided a method to study the anatomic effect of conservative treatment as well as a method to evaluate sciatic symptoms in relation to anatomic changes. (orig.)

  2. Sizing protein-templated gold nanoclusters by time resolved fluorescence anisotropy decay measurements

    Science.gov (United States)

    Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe

    2018-03-01

    Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation.

  3. Sizing protein-templated gold nanoclusters by time resolved fluorescence anisotropy decay measurements.

    Science.gov (United States)

    Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe

    2018-03-15

    Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. High temporal resolution in situ measurement of the effective particle size characteristics of fluvial suspended sediment.

    Science.gov (United States)

    Williams, N D; Walling, D E; Leeks, G J L

    2007-03-01

    This paper reports the use of a LISST-100 device to monitor the effective particle size characteristics of suspended sediment in situ, and at a quasi-continuous temporal resolution. The study site was located on the River Exe at Thorverton, Devon, UK. This device has not previously been utilized in studies of fluvial suspended sediment at the storm event scale, and existing studies of suspended sediment dynamics have not involved such a high temporal resolution for extended periods. An evaluation of the field performance of the instrument is presented, with respect to innovative data collection and analysis techniques. It was found that trends in the effective particle size distribution (EPSD) and degree of flocculation of suspended sediment at the study site were highly complex, and showed significant short-term variability that has not previously been documented in the fluvial environment. The collection of detailed records of EPSD facilitated interpretation of the dynamic evolution of the size characteristics of suspended sediment, in relation to its likely source and delivery and flocculation mechanisms. The influence of measurement frequency is considered in terms of its implications for future studies of the particle size of fluvial suspended sediment employing in situ data acquisition.

  5. From nanoparticles to large aerosols: Ultrafast measurement methods for size and concentration

    International Nuclear Information System (INIS)

    Keck, Lothar; Spielvogel, Juergen; Grimm, Hans

    2009-01-01

    A major challenge in aerosol technology is the fast measurement of number size distributions with good accuracy and size resolution. The dedicated instruments are frequently based on particle charging and electric detection. Established fast systems, however, still feature a number of shortcomings. We have developed a new instrument that constitutes of a high flow Differential Mobility Analyser (high flow DMA) and a high sensitivity Faraday Cup Electrometer (FCE). The system enables variable flow rates of up to 150 lpm, and the scan time for size distribution can be shortened considerably due to the short residence time of the particles in the DMA. Three different electrodes can be employed in order to cover a large size range. First test results demonstrate that the scan time can be reduced to less than 1 s for small particles, and that the results from the fast scans feature no significant difference to the results from established slow method. The fields of application for the new instrument comprise the precise monitoring of fast processes with nanoparticles, including monitoring of engine exhaust in automotive research.

  6. From nanoparticles to large aerosols: Ultrafast measurement methods for size and concentration

    Science.gov (United States)

    Keck, Lothar; Spielvogel, Jürgen; Grimm, Hans

    2009-05-01

    A major challenge in aerosol technology is the fast measurement of number size distributions with good accuracy and size resolution. The dedicated instruments are frequently based on particle charging and electric detection. Established fast systems, however, still feature a number of shortcomings. We have developed a new instrument that constitutes of a high flow Differential Mobility Analyser (high flow DMA) and a high sensitivity Faraday Cup Electrometer (FCE). The system enables variable flow rates of up to 150 lpm, and the scan time for size distribution can be shortened considerably due to the short residence time of the particles in the DMA. Three different electrodes can be employed in order to cover a large size range. First test results demonstrate that the scan time can be reduced to less than 1 s for small particles, and that the results from the fast scans feature no significant difference to the results from established slow method. The fields of application for the new instrument comprise the precise monitoring of fast processes with nanoparticles, including monitoring of engine exhaust in automotive research.

  7. Measurement of the size of spherical nanoparticles by means of atomic force microscopy

    International Nuclear Information System (INIS)

    Couteau, O; Roebben, G

    2011-01-01

    Several techniques are nowadays available to determine the size distribution of nanoparticulate matter. Among these techniques, atomic force microscopy (AFM) is especially valuable because it can provide three-dimensional information on the shape of individual nanoparticles. This paper describes a new method to determine the size distribution of a population of spherical nanoparticles deposited on a hard substrate. The method is based on the acquisition and analysis of topographical AFM images. The size of individual nanoparticles is obtained by fitting the topographical region associated with the nanoparticle with a sphere. Tests on model systems based on nanoparticle reference materials consisting of polystyrene (PS) latex suspensions show promising results. The measured mean particle size is larger than the reference value, but this is a predictable effect of the AFM tip shape. Tests on a bi-modal mixture of two PS latex reference materials show the impact of the quality of the dispersion of the nanoparticles on the results obtained with the new technique

  8. Measurement of an electronic cigarette aerosol size distribution during a puff

    Directory of Open Access Journals (Sweden)

    Belka Miloslav

    2017-01-01

    Full Text Available Electronic cigarettes (e-cigarettes have become very popular recently because they are marketed as a healthier alternative to tobacco smoking and as a useful tool to smoking cessation. E-cigarettes use a heating element to create an aerosol from a solution usually consisting of propylene glycol, glycerol, and nicotine. Despite the wide spread of e-cigarettes, information about aerosol size distributions is rather sparse. This can be caused by the relative newness of e-cigarettes and by the difficulty of the measurements, in which one has to deal with high concentration aerosol containing volatile compounds. Therefore, we assembled an experimental setup for size measurements of e-cigarette aerosol in conjunction with a piston based machine in order to simulate a typical puff. A TSI scanning mobility particle sizer 3936 was employed to provide information about particle concentrations and sizes. An e-cigarette commercially available on the Czech Republic market was tested and the results were compared with a conventional tobacco cigarette. The particles emitted from the e-cigarette were smaller than those of the conventional cigarette having a CMD of 150 and 200 nm. However, the total concentration of particles from e-cigarette was higher.

  9. Measurement of an electronic cigarette aerosol size distribution during a puff

    Science.gov (United States)

    Belka, Miloslav; Lizal, Frantisek; Jedelsky, Jan; Jicha, Miroslav; Pospisil, Jiri

    Electronic cigarettes (e-cigarettes) have become very popular recently because they are marketed as a healthier alternative to tobacco smoking and as a useful tool to smoking cessation. E-cigarettes use a heating element to create an aerosol from a solution usually consisting of propylene glycol, glycerol, and nicotine. Despite the wide spread of e-cigarettes, information about aerosol size distributions is rather sparse. This can be caused by the relative newness of e-cigarettes and by the difficulty of the measurements, in which one has to deal with high concentration aerosol containing volatile compounds. Therefore, we assembled an experimental setup for size measurements of e-cigarette aerosol in conjunction with a piston based machine in order to simulate a typical puff. A TSI scanning mobility particle sizer 3936 was employed to provide information about particle concentrations and sizes. An e-cigarette commercially available on the Czech Republic market was tested and the results were compared with a conventional tobacco cigarette. The particles emitted from the e-cigarette were smaller than those of the conventional cigarette having a CMD of 150 and 200 nm. However, the total concentration of particles from e-cigarette was higher.

  10. Velocity and size distribution measurement of suspension droplets using PDPA technique

    Science.gov (United States)

    Amiri, Shahin; Akbarnozari, Ali; Moreau, Christian; Dolatabadi, Ali

    2015-11-01

    The creation of fine and uniform droplets from a bulk of liquid is a vital process in a variety of engineering applications, such as atomization in suspension plasma spray (SPS) in which the submicron coating materials are injected to the plasma gas through the suspension droplets. The size and velocity of these droplets has a great impact on the interaction of the suspension with the gas flow emanating from a plasma torch and can consequently affect the mechanical and chemical properties of the resultant coatings. In the current study, an aqueous suspension of small glass particles (2-8 μm) was atomized by utilizing an effervescent atomizer of 1 mm orifice diameter which involves bubbling gas (air) directly into the liquid stream. The gas to liquid ratio (GLR) was kept constant at 6% throughout this study. The mass concentration of glass particles varied in the range between 0.5 to 5% in order to investigate the effect of suspension viscosity and surface tension on the droplet characteristics, such as velocity and size distributions. These characteristics were simultaneously measured by using a non-intrusive optical technique, Phase Doppler Particle Anemometry (PDPA), which is based on the light signal scattered from the droplets moving in a measurement volume. The velocity and size distribution of suspension droplets were finally compared to those of distilled water under identical conditions. The results showed a different atomization behaviors due to the reduction in surface tension of the suspension spray.

  11. Improved pedagogy for linear differential equations by reconsidering how we measure the size of solutions

    Science.gov (United States)

    Tisdell, Christopher C.

    2017-11-01

    For over 50 years, the learning of teaching of a priori bounds on solutions to linear differential equations has involved a Euclidean approach to measuring the size of a solution. While the Euclidean approach to a priori bounds on solutions is somewhat manageable in the learning and teaching of the proofs involving second-order, linear problems with constant co-efficients, we believe it is not pedagogically optimal. Moreover, the Euclidean method becomes pedagogically unwieldy in the proofs involving higher-order cases. The purpose of this work is to propose a simpler pedagogical approach to establish a priori bounds on solutions by considering a different way of measuring the size of a solution to linear problems, which we refer to as the Uber size. The Uber form enables a simplification of pedagogy from the literature and the ideas are accessible to learners who have an understanding of the Fundamental Theorem of Calculus and the exponential function, both usually seen in a first course in calculus. We believe that this work will be of mathematical and pedagogical interest to those who are learning and teaching in the area of differential equations or in any of the numerous disciplines where linear differential equations are used.

  12. Single-shot beam size measurements using visible-light interferometry at CESR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.T., E-mail: sw565@cornell.edu [Cornell Laboratory for Accelerator-based Science and Education, Cornell University, Ithaca, NY 14853 (United States); Holtzapple, R. [Physics Department, California Polytechnic State University, San Luis Obispo, CA 93407 (United States); Rubin, D.L. [Cornell Laboratory for Accelerator-based Science and Education, Cornell University, Ithaca, NY 14853 (United States)

    2017-03-01

    A new primary mirror for a visible-light beam size monitor (vBSM) was designed and installed in the Cornell Electron-Positron Storage Ring (CESR). The vertical angular acceptance of the mirror was doubled to allow double-slit interferometry with large slit separation (>12 mm). In addition, the diffraction associated with the first generation mirror has been eliminated. The resolution of the vertical beam size measurements has been dramatically improved but is ultimately limited by the beam motion. Two fast-response detectors, a Photomultiplier Tube (PMT) array and a gated camera, were employed to study the beam motion. The advantages and limitations of both devices are discussed in this paper. The gated camera was also used to measure single-shot beam width and motion of each bunch in a multi-bunch train. We measured significantly more horizontal motion of electron as compared to positron bunch trains in otherwise identical machine condition. This difference may be a signature for the difference between electron cloud build-up for positron bunch trains versus ions effects characteristic of electron bunch trains. - Highlights: • A new extraction mirror for synchrotron radiation was designed and installed in CESR. • The sensitivity of interferometer was increased and the diffraction effect was eliminated. • Two fast-response detectors were employed to study the effect of beam motion. • First time single-shot bunch-by-bunch horizontal beam size measurements using interferometry was observed from gated camera. • The difference in single bunch horizontal dynamics was observed between a positron and an electron train.

  13. Large Portions Encourage the Selection of Palatable Rather Than Filling Foods.

    Science.gov (United States)

    Brunstrom, Jeffrey M; Jarvstad, Andreas; Griggs, Rebecca L; Potter, Christina; Evans, Natalie R; Martin, Ashley A; Brooks, Jon Cw; Rogers, Peter J

    2016-10-01

    Portion size is an important driver of larger meals. However, effects on food choice remain unclear. Our aim was to identify how portion size influences the effect of palatability and expected satiety on choice. In Study 1, adult participants (n = 24, 87.5% women) evaluated the palatability and expected satiety of 5 lunchtime meals and ranked them in order of preference. Separate ranks were elicited for equicaloric portions from 100 to 800 kcal (100-kcal steps). In Study 2, adult participants (n = 24, 75% women) evaluated 9 meals and ranked 100-600 kcal portions in 3 contexts (scenarios), believing that 1) the next meal would be at 1900, 2) they would receive only a bite of one food, and 3) a favorite dish would be offered immediately afterwards. Regression analysis was used to quantify predictors of choice. In Study 1, the extent to which expected satiety and palatability predicted choice was highly dependent on portion size (P palatability (100-kcal portions: expected satiety, β: 0.42; palatability, β: 0.46). With larger portions, palatability was a strong predictor (600-kcal portions: β: 0.53), and expected satiety was a poor or negative predictor (600-kcal portions: β: -0.42). In Study 2, this pattern was moderated by context (P = 0.024). Results from scenario 1 replicated Study 1. However, expected satiety was a poor predictor in both scenario 2 (expected satiety was irrelevant) and scenario 3 (satiety was guaranteed), and palatability was the primary driver of choice across all portions. In adults, expected satiety influences food choice, but only when small equicaloric portions are compared. Larger portions not only promote the consumption of larger meals, but they encourage the adoption of food choice strategies motivated solely by palatability. © 2016 American Society for Nutrition.

  14. Prevalence of advanced adenomas in small and diminutive colon polyps using direct measurement of size.

    Science.gov (United States)

    Tsai, Franklin C; Strum, Williamson B

    2011-08-01

    Most studies reporting polyp size use visual estimates. Determining the prevalence of advanced histology based on direct measurement of polyp size may help guide the management of polyps found at optical colonoscopy (OC) and CT colonography (CTC). We designed a large, prospective study to assess the prevalence of advanced adenomas based on direct measurement of polyp size by a certified pathologists' assistant as reported in the pathology report. Patients between 40 and 89 years of age who presented for screening colonoscopy were included in our study. Advanced adenomas were defined as ≥10 mm or ≥25% villous features, high grade dysplasia or cancer. Polyps were divided by size into three groups: diminutive (≤5 mm), small (6-9 mm) and large (≥10 mm). If more than one adenoma was present, the most advanced was used for analysis. We evaluated 6,905 consecutive patients referred for colonoscopy between January 2005 and December 2006. Of the 4,967 who met the inclusion criteria, the mean age was 58.8 and consisted of 59% women. Overall, 930 (18.7%) had an adenoma; 248 (5%) were advanced adenomas including 8 (0.16%) cancers. Of 89 polyps≥10 mm, 76 (85%) had advanced histology; of 247 polyps 6-9 mm, 67 (27%) were advanced; of 1,025 polyps ≤5 mm, 105 (10%) were advanced. Thus, 172 of 248 (69%) patients with advanced adenomas had small or diminutive adenomas. Our data indicate the majority (69%) of advanced adenomas are advanced adenomas (10%). These findings may help guide the management of sub-centimeter colon polyps found by OC or CTC.

  15. Concentrations and size distributions of fine aerosol particles measured at roof level in urban zone

    Science.gov (United States)

    Despiau, S.; Croci, D.

    2007-05-01

    During the experimental Field Experiments to Constrain Models of Atmospheric Pollution and Transport of Emissions (ESCOMPTE) campaign in June-July 2001, concentrations and size distributions of fine particles (14-722 nm) were measured at roof level in downtown Marseille (France). Part of the campaign was dedicated to the study of aerosol behavior in relation to strong photochemical events (which were identified as "IOP" days) and their regional modeling. The analysis of the concentration variations and the evolution of average diurnal size distribution showed that an "IOP day" is not characterized by a specific concentration or its variation, nor by a specific evolution of the average size distribution. The morning traffic rush is detected at roof level by a net increase in particle concentration over the whole size range measured, indicating a production of ultrafine particles by the traffic but also the raising to roof level of particles of the accumulation mode. The increase is observed about 1 hour after the traffic peak at street level, which is characterized by strong increases in NOx and CO concentrations. The corresponding flux of particles at roof level has been estimated around 3 × 104 cm-2 s-1. A specific signature characterized by a strong and rapid burst of concentration (factor 2 to 4 in 15 min) of particles between 25 and 50 nm, independent of the traffic source, has been detected on six occasions during the campaign. These events occur systematically around noon, in cases of strong radiation, low relative humidity, and common wind direction. Despite the high-diameter value of these particles, it is suggested that they could result from a specific "secondary aerosol process" event involving ozone, biogenic, and/or anthropogenic gas precursors like iodine and VOCs.

  16. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    Science.gov (United States)

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  17. Measurement of the environmental broadband electromagnetic waves in a mid-size European city.

    Science.gov (United States)

    Fernández-García, R; Gil, I

    2017-10-01

    In this paper, the level of exposure to broadband radiofrequency electromagnetic field in a mid-size European city was evaluated in accordance with the International Commission on Non-ionizing Radiation Protection guidelines from 1998. With the aim to analyse all the potential electromagnetic waves present in the city up to 18GHz, a total of 271 locations distributed along Terrassa (Spain) have been measured. To show the results in an easy-to-interpret way by the citizen, the results have been represented in a set of raster maps. The measurement results obtained showed that the electromagnetic wave measured in all broadband frequency range along the city is much lower than the safety level according to the international regulations for both public and occupational sectors. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Legal Portion in Russian Inheritance Law

    Science.gov (United States)

    Inshina, Roza; Murzalimova, Lyudmila

    2013-01-01

    In this paper the authors describe the right to inherit as one of the basic human rights guaranteed by the Constitution of the Russian Federation. The state has set rules according to which after a person's death, his or her property is inherited by other persons. The Russian civil legislation establishes the institution of legal portions that is…

  19. Carving up Word Meaning: Portioning and Grinding

    Science.gov (United States)

    Frisson, S.; Frazier, L.

    2005-01-01

    Two eye-tracking experiments investigated the processing of mass nouns used as count nouns and count nouns used as mass nouns. Following Copestake and Briscoe (1995), the basic or underived sense of a word was treated as the input to a derivational rule (''grinding'' or ''portioning'') which produced the derived sense as output. It was…

  20. Hardware compression using common portions of data

    Science.gov (United States)

    Chang, Jichuan; Viswanathan, Krishnamurthy

    2015-03-24

    Methods and devices are provided for data compression. Data compression can include receiving a plurality of data chunks, sampling at least some of the plurality of data chunks extracting a common portion from a number of the plurality of data chunks based on the sampling, and storing a remainder of the plurality of data chunks in memory.

  1. Portion control for the treatment of obesity in the primary care setting

    Directory of Open Access Journals (Sweden)

    Harris Katherine I

    2011-09-01

    Full Text Available Abstract Background The increasing prevalence of obesity is a significant health threat and a major public health challenge. A critical need exists to develop and evaluate practical methods for the treatment of obesity in the clinical setting. One of the factors contributing to the obesity epidemic is food portion sizes. Limited data are available on the efficacy of visual or tactile devices designed to enhance patient understanding and control of portion sizes. A portion control plate is a commercially-available product that can provide visual cues of portion size and potentially contribute to weight loss by enhancing portion size control among obese patients. This tool holds promise as a useful adjunct to dietary counseling. Our objective was to evaluate a portion control intervention including dietary counseling and a portion control plate to facilitate weight loss among obese patients in a primary care practice. Findings We randomized 65 obese patients [body mass index (BMI ≥ 30 and vs. -0.5% ± 2.2%; p = 0.041 and a non significant trend in weight change from baseline at 6 months (-2.1% ± 3.8% vs. -0.7% ± 3.7%; p = 0.232 compared with usual care. Nearly one-half of patients assigned to the portion control intervention who completed the study reported the overall intervention was helpful and the majority would recommend it to others. Conclusions Our findings suggest that a portion control intervention incorporating dietary counseling and a portion control plate may be effective for enhancing weight loss among obese subjects. A portion control intervention deserves further evaluation as a weight control strategy in the primary care setting. Trial registration Current controlled trials NCT01451554

  2. Aerosol particle size distribution in the stratosphere retrieved from SCIAMACHY limb measurements

    Science.gov (United States)

    Malinina, Elizaveta; Rozanov, Alexei; Rozanov, Vladimir; Liebing, Patricia; Bovensmann, Heinrich; Burrows, John P.

    2018-04-01

    health, stratospheric aerosol plays an important role in atmospheric chemistry and climate change. In particular, information about the amount and distribution of stratospheric aerosols is required to initialize climate models, as well as validate aerosol microphysics models and investigate geoengineering. In addition, good knowledge of stratospheric aerosol loading is needed to increase the retrieval accuracy of key trace gases (e.g. ozone or water vapour) when interpreting remote sensing measurements of the scattered solar light. The most commonly used characteristics to describe stratospheric aerosols are the aerosol extinction coefficient and Ångström coefficient. However, the use of particle size distribution parameters along with the aerosol number density is a more optimal approach. In this paper we present a new retrieval algorithm to obtain the particle size distribution of stratospheric aerosol from space-borne observations of the scattered solar light in the limb-viewing geometry. While the mode radius and width of the aerosol particle size distribution are retrieved, the aerosol particle number density profile remains unchanged. The latter is justified by a lower sensitivity of the limb-scattering measurements to changes in this parameter. To our knowledge this is the first data set providing two parameters of the particle size distribution of stratospheric aerosol from space-borne measurements of scattered solar light. Typically, the mode radius and w can be retrieved with an uncertainty of less than 20 %. The algorithm was successfully applied to the tropical region (20° N-20° S) for 10 years (2002-2012) of SCIAMACHY observations in limb-viewing geometry, establishing a unique data set. Analysis of this new climatology for the particle size distribution parameters showed clear increases in the mode radius after the tropical volcanic eruptions, whereas no distinct behaviour of the absolute distribution width could be identified. A tape recorder

  3. Does the incorporation of portion-control strategies in a behavioral program improve weight loss in a 1-year randomized controlled trial?

    Science.gov (United States)

    Rolls, B J; Roe, L S; James, B L; Sanchez, C E

    2017-03-01

    Controlling food portion sizes can help reduce energy intake, but the effect of different portion-control methods on weight management is not known. In a 1-year randomized trial, we tested whether the efficacy of a behavioral weight-loss program was improved by incorporating either of the two portion-control strategies instead of standard advice about eating less. The Portion-Control Strategies Trial included 186 women with obesity (81%) or overweight (19%). Participants were randomly assigned to one of three equally intensive behavioral programs, consisting of 19 individual sessions over 12 months. The Standard Advice Group was instructed to eat less food while making healthy choices, the Portion Selection Group was instructed to choose portions based on the energy density using tools such as food scales and the Pre-portioned Foods Group was instructed to structure meals around pre-portioned foods such as single-serving main dishes, for which some vouchers were provided. In an intention-to-treat analysis, a mixed-effects model compared weight loss trajectories across 23 measurements; at month 12, weight was measured for 151 participants (81%). The trajectories showed that the Pre-portioned Foods Group initially lost weight at a greater rate than the other two groups (P=0.021), but subsequently regained weight at a greater rate (P=0.0005). As a result, weight loss did not differ significantly across groups at month 6 (mean±s.e. 5.2±0.4 kg) or month 12 (4.5±0.5 kg). After 1 year, measured weight loss averaged 6% of baseline weight. The frequency of using portion-control strategies initially differed across groups, then declined over time and converged at months 6 and 12. Incorporating instruction on portion-control strategies within a 1-year behavioral program did not lead to a greater weight loss than standard advice. Using pre-portioned foods enhanced early weight loss, but this was not sustained over time. Long-term maintenance of behavioral strategies to

  4. Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chuyu [Peking Univ., Beijing (China)

    2012-12-31

    Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the

  5. Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

    International Nuclear Information System (INIS)

    Liu, Chuyu

    2012-01-01

    Beam diagnostics is an essential constituent of any accelerator, so that it is named as 'organs of sense' or 'eyes of the accelerator.' Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the

  6. Effect of size and composition of the body on absolute measurement of calcium in vivo

    International Nuclear Information System (INIS)

    Spinks, T.J.

    1979-01-01

    The effect of size and composition of the body on the measurement of total calcium in absolute units by neutron activation analysis is described. The neutron beam, produced from a cyclotron, was of mean energy 7.5 MeV. Counting of the activities induced in a patient was carried out with a multidetector whole body counter. Calibration of the system was achieved by using two phantoms of different sizes containing known quantities of calcium. The dimensions of various phantom sections were varied to determine the effect on efficiency of activation, an approximately linear relationship with body thickness being found. The influence of body habitus on counting efficiency was assessed by counting different patients who had been given known quantities of 42 K. The effects of (a) the non-uniform distribution of calcium and (b) the variation in density of different tissues on both activation and counting efficiency are discussed. It is estimated that the 68% confidence limits on the measurement of 49 Ca count rate per unit neutron fluence is +- 3.0% and on the measurement of calcium in grams +- 8.2%. (author)

  7. Improved technique for measuring the size distribution of black carbon particles in rainwater and snow samples

    Science.gov (United States)

    Mori, T.; Moteki, N.; Ohata, S.; Koike, M.; Azuma, K. G.; Miyazaki, Y.; Kondo, Y.

    2015-12-01

    Black carbon (BC) is the strongest contributor to sunlight absorption among atmospheric aerosols. Quantitative understanding of wet deposition of BC, which strongly affects the spatial distribution of BC, is important to improve our understandings on climate change. We have devised a technique for measuring the masses of individual BC particles in rainwater and snow samples, as a combination of a nebulizer and a single-particle soot photometer (SP2) (Ohata et al. 2011, 2013; Schwarz et al. 2012; Mori et al. 2014). We show two important improvements in this technique: 1)We have extended the upper limit of detectable BC particle diameter from 0.9 μm to about 4.0 μm by modifying the photodetector for measuring the laser-induced incandescence signal. 2)We introduced a pneumatic nebulizer Marin-5 (Cetac Technologies Inc., Omaha, NE, USA) and experimentally confirmed its high extraction efficiency (~50%) independent of particle diameter up to 2.0 μm. Using our improved system, we simultaneously measured the size distribution of BC particles in air and rainwater in Tokyo. We observed that the size distribution of BC in rainwater was larger than that in air, indicating that large BC particles were effectively removed by precipitation. We also observed BC particles with diameters larger than 1.0 μm, indicating that further studies of wet deposition of BC will require the use of the modified SP2.

  8. How much should I eat? Estimation of meal portions in anorexia nervosa.

    Science.gov (United States)

    Milos, Gabriella; Kuenzli, Cornelia; Soelch, Chantal Martin; Schumacher, Sonja; Moergeli, Hanspeter; Mueller-Pfeiffer, Christoph

    2013-04-01

    Pathological concern regarding one's weight and weight gain is a crucial feature of anorexia nervosa. Consequently, anorexia nervosa patients often claim that they are uncertain regarding the amount of food they should eat. The present study investigated whether individuals with anorexia nervosa show an altered estimation of meal portion sizes and whether this estimation is modulated by an intent-to-eat instruction (where patients are asked to imagine having to eat the presented meal), meal type and meal portion size. Twenty-four women with anorexia nervosa and 27 healthy women estimated, using a visual analogue scale, the size of six different portions of three different meals, with and without intent-to-eat instructions. Subjects with anorexia nervosa estimated the size of small and medium meal portions (but not large meal servings) as being significantly larger, compared to estimates of healthy controls. The overestimation of small meal portions by anorexia nervosa subjects was significantly greater in the intent-to-eat, compared to general, condition. These findings suggest that disturbed perceptions associated with anorexia nervosa not only include interoceptive awareness (i.e., body weight and shape), but also extend to external disorder-related objects such as meal portion size. Specific therapeutic interventions, such as training regarding meal portion evaluation, could address these difficulties. Copyright © 2013. Published by Elsevier Ltd.

  9. Numerical simulation of homogenization time measurement by probes with different volume size

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostek, M.; Jahoda, M.

    2004-01-01

    Results of continuous homogenization time measurement of liquid in a stirred tank depend on the scale of scrutiny. Experimental techniques use a probe, which is situated inside as a conductivity method, or outside of the tank as in the case of gamma-radiotracer methods. Expected value of homogenization time evaluated for a given degree of homogenization is higher when using the conductivity method because the conductivity probe measures relatively small volume in contrast to application of radiotracer, when the volume is much greater. Measurement through the wall of tank is a great advantage of radiotracer application but a comparison of the results with another method supposes a determination of measured volume, which is not easy. Simulation of measurement by CFD code can help to solve the problem. Methodology for CFD simulation of radiotracer experiments was suggested. Commercial software was used for simulation of liquid homogenization in mixed vessel with Rushton turbine. Numerical simulation of liquid homogenization time by CFD for different values of detected volume was confronted with measurement of homogenization time with conductivity probe and with different radioisotopes 198 Au, 82 Br and 24 Na. Detected size of the tank volume was affected by different energy of radioisotope used. (author)

  10. Crystallite Size and Microstrain Measurement of Cathode Material after Mechanical Milling using Neutron Diffraction Technique

    Directory of Open Access Journals (Sweden)

    A. Fajar

    2010-12-01

    Full Text Available The measurements of neutron diffraction patterns of commercially product and 10 hour mechanically milled cathode material lithium cobaltites (LiCoO2 have been performed. Rietveld analysis using FullProf does not show the change of crystal structure due to milling process, but the diffraction pattern has a lower intensity and the diffraction-line was broadening. The results of line-broadening study on milled sample using Rietveld methods detected that the microstrain was occurred in the sample with value 0.127080(35 % and the average crystallite size was 424.78(20 Å.

  11. Dissolution and particle size characterization of radioactive contaminants in Hanford facilities: Criteria for methods of measurement

    International Nuclear Information System (INIS)

    Briant, J.K.; James, A.C.

    1990-08-01

    The purpose of this document is to discuss experimental methods that can be applied to evaluate the rate at which an actinide material is likely to dissolve in biological fluids. Criteria are recommended for the design and conduct of meaningful experimental procedures to sample a representative size fraction of the source material, to measure the rate of radionuclide dissolution, and to apply the results to assign the material to an appropriate ICRP Publication-30 lung retention class (or mixture of classes). 26 refs., 3 figs., 3 tabs

  12. The IBAS image analyser and its use in particle size measurement

    International Nuclear Information System (INIS)

    Snelling, K.W.

    1984-10-01

    The Kontron image analyser (IBAS) is used at Winfrith primarily for size analysis of aerosol particles. The system incorporates two computers, IBAS 1 for system communication and control, and IBAS 2 containing the main image memories. The first is accessed via a keyboard or digitiser tablet, and output can be displayed on a monitor or in printed form. The contents of the image memories are displayed on a colour monitor. Automatic image analysis is described, with typical applications, including the measurement of monodisperse particles, sodium fire aerosols, reactor crud particles and cadmium-silver aerosol particles. (U.K.)

  13. Effect of detector size and position on measured vibration spectra of strings and rods

    International Nuclear Information System (INIS)

    Lipcsei, S.; Kiss, S.; Por, G.

    1993-04-01

    Weight functions of string and rod vibrations are described by standing and travelling wave models. The effects of detector size and position on the measured vibration spectra was investigated, and the main characteristics of the transfer function were calculated by a simple standing wave model. The theoretical results were compared with data from laboratory rod vibration experiments, and with pressure fluctuation spectra obtained at the Paks Nuclear Power Plant. In addition, some fundamental physical consequences can be made using the theory of superposition of travelling waves and their reflection on clamped rod ends. (R.P.) 5 refs.; 10 figs

  14. Ultrasonic delay measurements for the determination of the size of quasi-natural defects

    International Nuclear Information System (INIS)

    Proegler, H.

    1978-01-01

    Criteria in the form of delay measurements and phase assessments on ultrasonic pulses were worked out for a series of the most different reflection positions of the artificial, quasi-natural and natural kind which in many cases enable an differentiation of defects and the determination of the defect size. Even though it was not possible to completely clarify all effects occuring, such as reflection positions with undefined pulse orientations, the results sofar are still a contribution to the improvement of the stating ability of ultrasonic testing. (orig./RW) [de

  15. The role of perceived stress and gender on portion selection patterns.

    Science.gov (United States)

    Lim, E X; Sim, A Y; Forde, C G; Cheon, B K

    2018-06-01

    Stress is linked to increased preferences and consumption of palatable energy dense foods, particularly among females. Despite the role of stress on potentially obesogenic eating habits, its effect on pre-meal planning, such as the selection of portion sizes, remain unknown. Here, we investigated the relationship between perceived stress, gender, and intended portion sizes for diverse foods. Across two studies, increased perceived stress predicted larger (higher energy) intended portion sizes across a variety of food items among females, but not males. Additionally, for females, increased perceived stress was associated with lowered expectations of the satiety of foods presented, suggesting a potential mechanism by which stress may influence decisions about portion size. These findings reveal that the potentially obesogenic effects of stress on food judgments and behaviours (particularly among females) are not only expressed within meals, but also during more deliberate stages of planning that precedes meals. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. The measurement of pore size in porous and microporous materials using resonant ion beam backscattering

    International Nuclear Information System (INIS)

    Armitage, B.H.; Ramsay, J.D.F.; Brady, F.P.

    1978-01-01

    Established methods for measuring the size of pores in porous materials include those of mercury porosimetry and gas adsorption. A disadvantage of these methods is that only one determination can be made for each prepared specimen. A property of the ion beam backscattering method is that each specimen can be probed over the surface and also as a function of depth. Furthermore for microporous samples (pore width less than 2 nm) mercury penetration methods cannot be used because the high pressures involved make unreasonable demands in terms of mechanical strength. At the same time gas adsoption techniques are considerably restricted because capillary condensation is no longer possible because of the small size of the pores. A description is given of the methods of calculation of pore size from resonant ion beam backscattering data, with various assumptions for the pore and interpore path length distributions. Examples are shown of results obtained with highly porous silica gels where good agreement with gas adsoption has been achieved. Finally, some results obtained by scanning silica gels of lower porosity are also given. (Auth.)

  17. Methodology for sample preparation and size measurement of commercial ZnO nanoparticles

    Directory of Open Access Journals (Sweden)

    Pei-Jia Lu

    2018-04-01

    Full Text Available This study discusses the strategies on sample preparation to acquire images with sufficient quality for size characterization by scanning electron microscope (SEM using two commercial ZnO nanoparticles of different surface properties as a demonstration. The central idea is that micrometer sized aggregates of ZnO in powdered forms need to firstly be broken down to nanosized particles through an appropriate process to generate nanoparticle dispersion before being deposited on a flat surface for SEM observation. Analytical tools such as contact angle, dynamic light scattering and zeta potential have been utilized to optimize the procedure for sample preparation and to check the quality of the results. Meanwhile, measurements of zeta potential values on flat surfaces also provide critical information and save lots of time and efforts in selection of suitable substrate for particles of different properties to be attracted and kept on the surface without further aggregation. This simple, low-cost methodology can be generally applied on size characterization of commercial ZnO nanoparticles with limited information from vendors. Keywords: Zinc oxide, Nanoparticles, Methodology

  18. GRAIN-SIZE MEASUREMENTS OF FLUVIAL GRAVEL BARS USING OBJECT-BASED IMAGE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Pedro Castro

    2018-01-01

    Full Text Available Traditional techniques for classifying the average grain size in gravel bars require manual measurements of each grain diameter. Aiming productivity, more efficient methods have been developed by applying remote sensing techniques and digital image processing. This research proposes an Object-Based Image Analysis methodology to classify gravel bars in fluvial channels. First, the study evaluates the performance of multiresolution segmentation algorithm (available at the software eCognition Developer in performing shape recognition. The linear regression model was applied to assess the correlation between the gravels’ reference delineation and the gravels recognized by the segmentation algorithm. Furthermore, the supervised classification was validated by comparing the results with field data using the t-statistic test and the kappa index. Afterwards, the grain size distribution in gravel bars along the upper Bananeiras River, Brazil was mapped. The multiresolution segmentation results did not prove to be consistent with all the samples. Nonetheless, the P01 sample showed an R2 =0.82 for the diameter estimation and R2=0.45 the recognition of the eliptical ft. The t-statistic showed no significant difference in the efficiencies of the grain size classifications by the field survey data and the Object-based supervised classification (t = 2.133 for a significance level of 0.05. However, the kappa index was 0.54. The analysis of the both segmentation and classification results did not prove to be replicable.

  19. Indication of the radiofrequency induced lesion size by pre-ablation measurements

    DEFF Research Database (Denmark)

    Stagegaard, Niels; Petersen, Helen Høgh; Chen, Xu

    2005-01-01

    BACKGROUND: During radiofrequency ablation of arrhythmias tissue heating and hence lesion size depend on electrode-tissue contact and cooling of the electrode tip caused by cavitary blood flow. These factors are unique and unknown for each catheter placement in the beating heart. A tool for asses......BACKGROUND: During radiofrequency ablation of arrhythmias tissue heating and hence lesion size depend on electrode-tissue contact and cooling of the electrode tip caused by cavitary blood flow. These factors are unique and unknown for each catheter placement in the beating heart. A tool...... for assessing these factors prior to ablation may indicate the lesion size which will be obtained for any given catheter position. METHODS AND RESULTS: Radiofrequency ablation was performed in vitro on strips of left ventricular porcine myocardium during two different levels of convective cooling (0 or 0.1 m....../s), two different contact pressures (10 or 30 g) and parallel or perpendicular electrode-tissue orientation using 7F 4 mm tip catheters. Prior to ablation the impedance rise (DeltaIMP) caused by the obtained contact and the temperature rise with a 0.6 W 5 s test pulse (DeltaT) were measured. Subsequently...

  20. Measures of effect size for chi-squared and likelihood-ratio goodness-of-fit tests.

    Science.gov (United States)

    Johnston, Janis E; Berry, Kenneth J; Mielke, Paul W

    2006-10-01

    A fundamental shift in editorial policy for psychological journals was initiated when the fourth edition of the Publication Manual of the American Psychological Association (1994) placed emphasis on reporting measures of effect size. This paper presents measures of effect size for the chi-squared and the likelihood-ratio goodness-of-fit statistic tests.

  1. Do Between-Culture Differences Really Mean that People Are Different? A Look at Some Measures of Culture Effect Size.

    Science.gov (United States)

    Matsumoto, David; Grissom, Robert J.; Dinnel, Dale L.

    2001-01-01

    Recommends four measures of cultural effect size appropriate for cross-cultural research (standardized difference between two sample means, probabilistic superiority effect size measure, Cohen's U1, and point biserial correlation), demonstrating their efficacy on two data sets from previously published studies and arguing for their use in future…

  2. Analysis of vestibular schwannoma size in multiple dimensions: a comparative cohort study of different measurement techniques.

    Science.gov (United States)

    Varughese, J K; Wentzel-Larsen, T; Vassbotn, F; Moen, G; Lund-Johansen, M

    2010-04-01

    In this volumetric study of the vestibular schwannoma, we evaluated the accuracy and reliability of several approximation methods that are in use, and determined the minimum volume difference that needs to be measured for it to be attributable to an actual difference rather than a retest error. We also found empirical proportionality coefficients for the different methods. DESIGN/SETTING AND PARTICIPANTS: Methodological study with investigation of three different VS measurement methods compared to a reference method that was based on serial slice volume estimates. These volume estimates were based on: (i) one single diameter, (ii) three orthogonal diameters or (iii) the maximal slice area. Altogether 252 T1-weighted MRI images with gadolinium contrast, from 139 VS patients, were examined. The retest errors, in terms of relative percentages, were determined by undertaking repeated measurements on 63 scans for each method. Intraclass correlation coefficients were used to assess the agreement between each of the approximation methods and the reference method. The tendency for approximation methods to systematically overestimate/underestimate different-sized tumours was also assessed, with the help of Bland-Altman plots. The most commonly used approximation method, the maximum diameter, was the least reliable measurement method and has inherent weaknesses that need to be considered. This includes greater retest errors than area-based measurements (25% and 15%, respectively), and that it was the only approximation method that could not easily be converted into volumetric units. Area-based measurements can furthermore be more reliable for smaller volume differences than diameter-based measurements. All our findings suggest that the maximum diameter should not be used as an approximation method. We propose the use of measurement modalities that take into account growth in multiple dimensions instead.

  3. Measurement of Heart size by mass chest X-ray in Medical students

    Energy Technology Data Exchange (ETDEWEB)

    Wai, Khin San; Mon, Khin Aye [Department of Physiology, Institute of Medicine, Mandalay (Myanmar)

    1971-07-01

    Mass miniature P-A view chest X-ray films of 83 students were taken at the TB clinic and were used for measuring the heart size. Measurements taken on 70 mm film were changed to the equivalent values for standard 6 foot chest films, by multiplying with a factor 5.23 which is the ratio between 70 mm mass miniature X-ray film and 6 foot chest film. Frontal cardiac area was also calculated. The mean heart diameters and frontal cardiac area for 54 male students were transverse diameter-11.30 cm, length-11.98 cm, breadth-10.32 cm, frontal area-106.50 sq cm and aortic diameter-5.31 cm. Those for 28 female students were:transverse diameter-10.27 cm, length-11.56, breadth-9.45 cm, frontal area-88.70 sq cm and aortic diameter-4.75 cm.

  4. Measurement of Heart size by mass chest X-ray in Medical students

    International Nuclear Information System (INIS)

    Khin San Wai; Khin Aye Mon

    1971-01-01

    Mass miniature P-A view chest X-ray films of 83 students were taken at the TB clinic and were used for measuring the heart size. Measurements taken on 70 mm film were changed to the equivalent values for standard 6 foot chest films, by multiplying with a factor 5.23 which is the ratio between 70 mm mass miniature X-ray film and 6 foot chest film. Frontal cardiac area was also calculated. The mean heart diameters and frontal cardiac area for 54 male students were transverse diameter-11.30 cm, length-11.98 cm, breadth-10.32 cm, frontal area-106.50 sq cm and aortic diameter-5.31 cm. Those for 28 female students were:transverse diameter-10.27 cm, length-11.56, breadth-9.45 cm, frontal area-88.70 sq cm and aortic diameter-4.75 cm

  5. Automated translating beam profiler for in situ laser beam spot-size and focal position measurements

    Science.gov (United States)

    Keaveney, James

    2018-03-01

    We present a simple and convenient, high-resolution solution for automated laser-beam profiling with axial translation. The device is based on a Raspberry Pi computer, Pi Noir CMOS camera, stepper motor, and commercial translation stage. We also provide software to run the device. The CMOS sensor is sensitive over a large wavelength range between 300 and 1100 nm and can be translated over 25 mm along the beam axis. The sensor head can be reversed without changing its axial position, allowing for a quantitative estimate of beam overlap with counter-propagating laser beams. Although not limited to this application, the intended use for this device is the automated measurement of the focal position and spot-size of a Gaussian laser beam. We present example data of one such measurement to illustrate device performance.

  6. Carotid body size measured by computed tomographic angiography in individuals born prematurely.

    Science.gov (United States)

    Bates, Melissa L; Welch, Brian T; Randall, Jess T; Petersen-Jones, Humphrey G; Limberg, Jacqueline K

    2018-05-24

    We tested the hypothesis that the carotid bodies would be smaller in individuals born prematurely or exposed to perinatal oxygen therapy when compared individuals born full term that did not receive oxygen therapy. A retrospective chart review was conducted on patients who underwent head/neck computed tomography angiography (CTA) at the Mayo Clinic between 10 and 40 years of age (n = 2503). Patients were identified as premature ( body images captured during the CTA were performed. Carotid body visualization was possible in 43% of patients and 52% of age, sex, and body mass index (BMI)-matched controls but only 17% of juvenile preterm subjects (p = 0.07). Of the carotid bodies that could be visualized, widest axial measurements of the carotid bodies in individuals born prematurely (n = 7, 34 ± 4 weeks gestation, birth weight: 2460 ± 454 g; average size: 2.5 ± 0.2 cm) or individuals exposed to perinatal oxygen therapy (n = 3, 38 ± 2 weeks gestation, Average size: 2.2 ± 0.1 cm) were not different when compared to controls (2.3 ± 0.2 cm and 2.3 ± 0.2 cm, respectively, p > 0.05). Carotid body size, as measured using CTA, is not smaller in adults born prematurely or exposed to perinatal oxygen therapy when compared to sex, age, and BMI-matched controls. However, carotid body visualization was lower in juvenile premature patients. The decreased ability to visualize the carotid bodies in these individuals may be a result of their prematurity. Copyright © 2018. Published by Elsevier B.V.

  7. Measurement of the activity size distribution of the polonium-218 under laboratory conditions

    International Nuclear Information System (INIS)

    Yoon, Suk Chul; Ha, Chung Woo

    1992-01-01

    A number of investigators have reported the formation of the radiolytic ultrafine particles produced by the interaction of ionizing radiation with water vapor. Previous studies have suggested that a very high localized concentration of the OH radical produced by the radiolysis of water can react with trace gas like organic vapors and produce lower vapor pressure compounds that can then nucleate. In order to determine water vapor and trace gas dependence of the active, positive-charged, first radon daughter, an experiment was conducted using a radon chamber. The activity size distribution of the radon daughter in the range of 0.5 - 100 nm was measured using the stacked wire screens sampler. Measurements were taken for different relative humidity. The resultant activity size distributions were analyzed. The addition of water vapor to the radon carrier gases resulted in the formation of ultrafine particles by OH radicals formed radon radiolysis. It may be due to the neutralization of charged Po-218 ion with water vapor through the radiolysis

  8. Development of stress relaxation measurement by a small size C-ring specimen method

    International Nuclear Information System (INIS)

    Shimanuki, Shizuka; Nakata, Kiyotomo; Kasahara, Shigeki; Kuniya, Jiro

    2002-01-01

    A stress relaxation measurement method has been developed by using C-ring specimens, and a specimen size effect has been evaluated taking radiation-induced stress relaxation into consideration. C-ring specimens were stressed by forcing a wedge in the gap. Giving an appropriate eccentric configuration in the half of the ring opposite the gap, the stress gradient along the circumference was eliminated in the section and the stress level could be varied by changing the gap spacing. The validity of the C-ring test method was confirmed by thermally stress relaxation experiments at annealing temperatures from 300 to 600degC for 1 min to 200 h in carbon steel: considerable stress relaxation could be measured for all levels of applied stress even at relatively low annealing temperatures. The relaxation results obtained from the C-ring test were in good agreement with those from a uniaxial tensile stress relaxation test. The smaller C-ring specimen with about 40 mm diameter, which is required for radiation-induced stress relaxation test, also showed adequate accuracy on stress relaxation at 600 to 830degC in stainless steel, compared with the large size C-ring specimen test. (author)

  9. The detection and measurement of the electrical mobility size distributions associated with radon decay products

    International Nuclear Information System (INIS)

    Fei, Lin.

    1996-04-01

    The potential risk of lung cancer has evoked interest in the properties of radon decay products. There are two forms of this progeny: either attached to ambient aerosols, or still in the status of ions/molecules/small clusters. This ''unattached'' activity would give a higher dose per unit of airborne activity than the ''attached'' progeny that are rather poorly deposited. In this thesis, a system for determining unattached radon decay products electrical mobility size distribution by measuring their electrical mobilities was developed, based on the fact that about 88% of 218 Po atoms have unit charge at the end of their recoil after decay from 222 Rn, while the remainder are neutral. Essential part of the setup is the radon-aerosol chamber with the Circular Electrical Mobility Spectrometer (CEMS) inside. CEMS is used for sampling and classifying the charged radioactive clusters produced in the chamber. An alpha- sensitive plastic, CR-39 disk, is placed in CEMS as an inlaid disk electrode and the alpha particle detector. CEMS showed good performance in fine inactive particles' classification. If it also works well for radon decay products, it can offer a convenient size distribution measurement for radioactive ultrafine particles. However, the experiments did not obtain an acceptable resolution. Suggestions are made for solving this problem

  10. X-ray beam size measurements on the Advanced Test Accelerator

    International Nuclear Information System (INIS)

    Struve, K.W.; Chambers, F.W.; Lauer, E.J.; Slaughter, D.R.

    1986-01-01

    The electron beam size has been determined on the Advanced Test Accelerator (ATA) by intercepting the beam with a target and measuring the resulting x-ray intensity as a function of time as the target is moved through the beam. Several types of targets have been used. One is a tantalum rod which extends completely across the drift chamber. Another is a tungsten powder filled carbon crucible. Both of these probes are moved from shot to shot so that the x-ray signal intensity varies with probe position. A third is a larger tantalum disk which is inserted on beam axis to allow determining beam size on a one shot basis. The x-ray signals are detected with an MCP photomultiplier tube located at 90 0 to the beamline. It is sufficiently shielded to reject background x-rays and neutrons. The signals were digitized, recorded and later unfolded to produce plots of x-ray intensity versus probe position for several times during the pulse. The presumption that the x-ray intensity is proportional to beam current density is checked computationally. Details of the probe construction and PMT shielding, as well as sample measurements are given

  11. Method development and validation for measuring the particle size distribution of pentaerythritol tetranitrate (PETN) powders.

    Energy Technology Data Exchange (ETDEWEB)

    Young, Sharissa Gay

    2005-09-01

    Currently, the critical particle properties of pentaerythritol tetranitrate (PETN) that influence deflagration-to-detonation time in exploding bridge wire detonators (EBW) are not known in sufficient detail to allow development of a predictive failure model. The specific surface area (SSA) of many PETN powders has been measured using both permeametry and gas absorption methods and has been found to have a critical effect on EBW detonator performance. The permeametry measure of SSA is a function of particle shape, packed bed pore geometry, and particle size distribution (PSD). Yet there is a general lack of agreement in PSD measurements between laboratories, raising concerns regarding collaboration and complicating efforts to understand changes in EBW performance related to powder properties. Benchmarking of data between laboratories that routinely perform detailed PSD characterization of powder samples and the determination of the most appropriate method to measure each PETN powder are necessary to discern correlations between performance and powder properties and to collaborate with partnering laboratories. To this end, a comparison was made of the PSD measured by three laboratories using their own standard procedures for light scattering instruments. Three PETN powder samples with different surface areas and particle morphologies were characterized. Differences in bulk PSD data generated by each laboratory were found to result from variations in sonication of the samples during preparation. The effect of this sonication was found to depend on particle morphology of the PETN samples, being deleterious to some PETN samples and advantageous for others in moderation. Discrepancies in the submicron-sized particle characterization data were related to an instrument-specific artifact particular to one laboratory. The type of carrier fluid used by each laboratory to suspend the PETN particles for the light scattering measurement had no consistent effect on the resulting

  12. Leakage detection device for weld portion

    International Nuclear Information System (INIS)

    Shinkawa, Toshio; Setokuchi, Sadayuki.

    1994-01-01

    The present invention concerns leakage detection device for weld portions, for example, in a nuclear reactor cavity, which can rapidly detect by remote control. That is, a detection device capable of self running and stopping on a guide rail along a weld line is disposed. The detection device comprises a coating mechanism for automatically coating soap water to the weld portion, a vacuum box capable of evacuating the coated surface and a camera for detecting the presence or absence of the soap bubbles generated under the evacuation. Such a device can conduct, by remote control, self running/stopping along with the weld line, coating of the soap water, settling of the vacuum box and confirmation and recording of foaming by using a television monitor. Accordingly, leakage in the weld portion in the reactor cavity or the like can be inspected. As a result, it greatly contributes to improvement of danger upon worker's operation at high place, detection accuracy and reliability of detection and shortening of operation period. (I.S.)

  13. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    International Nuclear Information System (INIS)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo; Bamberg, Fabian; O'Donnell, Christopher J.; Fox, Caroline S.

    2010-01-01

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 ± 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 ± 8 cm 2 , 14.7 ± 1.5 cm and 0.54 ± 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 ± 45 cm 3 and 124.2 ± 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  14. The relationship between elastomer opacity, colorimeter beam size, and measured colorimetric response.

    Science.gov (United States)

    Rugh, E H; Johnston, W M; Hesse, N S

    1991-01-01

    The effect of opacity on the colorimetric responses of large-area and small-area colorimeters was determined using an elastomer intended for maxillofacial prosthetics use and containing various pigments at different concentrations. Opacity was determined by calculating the contrast ratio of 2-mm-thick specimens against black and white backings, using Kubelka-Munk analyses to correct for thickness and backing color variations. The measure of comparison of the two colorimeters was the relative difference in tristimulus reflectance, with the tristimulus reflectance of the large-area colorimeter as the basis of the relative difference. A significant quadratic relationship was found between contrast ratio and the relative difference in tristimulus reflectance. This relationship may be used to describe opacity without the need to make optical observations or measurements of a thin layer of material on contrasting backings. The small-area colorimeter produced color parameters that are a measure of the combined effects of both color and opacity. The importance of beam size considerations of optical measuring devices for translucent natural and prosthetic materials was emphasized.

  15. Relationship between overnight energy expenditure and BMR measured in a room-sized calorimeter.

    Science.gov (United States)

    Seale, J L; Conway, J M

    1999-02-01

    The purpose of this study was to determine if overnight energy expenditure, the lowest energy expenditure sustained for 60 min during the night, measured and predicted basal metabolic rate are equivalent. Overnight energy expenditure (ON-EE), the lowest energy expenditure sustained for 60 min during sleep (LS-EE) and basal metabolic rate (BMR) were measured two to seven times in a room-sized indirect calorimeter in 69 adult subjects. Subjects' gender, age, weight and height were also used to predict BMR (FAO/WHO/UNU, 1985) (BMR-WHO). Beltsville Human Nutrition Research Center, Beltsville, MD, USA. The results from calorimetry measurements (mean +/- s.d.) included: ON-EE (6.87 +/- 0.99 MJ/d), LS-EE (6.18 +/- 0.94 MJ/d) and BMR (6.87 +/- 0.99 MJ/d). Predicted BMR mean was: BMR-WHO, 6.95 +/- 1.03. The mean within-subject difference for the calorimetry measurements were: ON-EE, 0.21 MJ/d; LS-EE, 0.16 MJ/d; and BMR, 0.34 MJ/d. Results indicate there was no significant difference between ON-EE, BMR and BMR-WHO. LS-EE was significantly lower (P BMR and BMR-WHO. These results indicate that while metabolic rate drops significantly below BMR during sleep, overnight metabolic rate and BMR are equivalent.

  16. Comparison of Global Sizing Velocimetry and Phase Doppler Anemometry measurements of alternative jet fuel sprays

    Science.gov (United States)

    Sadr, Reza; Kannaiyan, Kumaran

    2013-11-01

    Atomization plays a crucial precursor role in liquid fuel combustion that directly affects the evaporation, mixing, and emission levels. Laser diagnostic techniques are often used to study the spray characteristics of liquid fuels. The objective of this work is to compare the spray measurements of Gas-to Liquid (GTL) jet fuels obtained using Global Sizing Velocimetry (GSV) and Phase Doppler Anemometry (PDA) techniques at global and local levels, respectively. The chemical and physical properties of GTL fuels are different from conventional jet fuels, owing to the difference in their production methodology. In this work, the experimental facility, the measurement techniques, and spray characteristics of two different GTL fuels are discussed and compared with those of Jet A-1 fuel. Results clearly demonstrate that although the global measurement gives an overall picture of the spray, fine details are obtained only through local measurements and complement in gaining more inferences into the spray characteristics. The results also show a close similarity in spray characteristics between GTL and Jet A-1 fuels. Funded by Qatar Science and Technology Park.

  17. Measures of Body Size and Composition and Risk of Incident Atrial Fibrillation in Older People

    Science.gov (United States)

    Karas, Maria G.; Yee, Laura M.; Biggs, Mary L.; Djoussé, Luc; Mukamal, Kenneth J.; Ix, Joachim H.; Zieman, Susan J.; Siscovick, David S.; Gottdiener, John S.; Rosenberg, Michael A.; Kronmal, Richard A.; Heckbert, Susan R.; Kizer, Jorge R.

    2016-01-01

    Various anthropometric measures, including height, have been associated with atrial fibrillation (AF). This raises questions about the appropriateness of using ratio measures such as body mass index (BMI), which contains height squared in its denominator, in the evaluation of AF risk. Among older adults, the optimal anthropometric approach to risk stratification of AF remains uncertain. Anthropometric and bioelectrical impedance measures were obtained from 4,276 participants (mean age = 72.4 years) free of cardiovascular disease in the Cardiovascular Health Study. During follow-up (1989–2008), 1,050 cases of AF occurred. BMI showed a U-shaped association, whereas height, weight, waist circumference, hip circumference, fat mass, and fat-free mass were linearly related to incident AF. The strongest adjusted association occurred for height (per each 1-standard-deviation increment, hazard ratio = 1.38, 95% confidence interval: 1.25, 1.51), which exceeded all other measures, including weight (hazard ratio = 1.21, 95% confidence interval: 1.13, 1.29). Combined assessment of log-transformed weight and height showed regression coefficients that departed from the 1 to −2 ratio inherent in BMI, indicating a loss of predictive information. Risk estimates for AF tended to be stronger for hip circumference than for waist circumference and for fat-free mass than for fat mass, which was explained largely by height. These findings highlight the prominent role of body size and the inadequacy of BMI as determinants of AF in older adults. PMID:27188936

  18. Impact of and correction for instrument sensitivity drift on nanoparticle size measurements by single-particle ICP-MS

    Science.gov (United States)

    El Hadri, Hind; Petersen, Elijah J.; Winchester, Michael R.

    2016-01-01

    The effect of ICP-MS instrument sensitivity drift on the accuracy of NP size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 nm and 60 nm gold nanoparticles. PMID:26894759

  19. Simultaneous measurement of monocomponent droplet temperature/refractive index, size and evaporation rate with phase rainbow refractometry

    Science.gov (United States)

    Wu, Yingchun; Crua, Cyril; Li, Haipeng; Saengkaew, Sawitree; Mädler, Lutz; Wu, Xuecheng; Gréhan, Gérard

    2018-07-01

    The accurate measurements of droplet temperature, size and evaporation rate are of great importance to characterize the heat and mass transfer during evaporation/condensation processes. The nanoscale size change of a micron-sized droplet exactly describes its transient mass transfer, but is difficult to measure because it is smaller than the resolutions of current size measurement techniques. The Phase Rainbow Refractometry (PRR) technique is developed and applied to measure droplet temperature, size and transient size changes and thereafter evaporation rate simultaneously. The measurement principle of PRR is theoretically derived, and it reveals that the phase shift of the time-resolved ripple structures linearly depends on, and can directly yield, nano-scale size changes of droplets. The PRR technique is first verified through the simulation of rainbows of droplets with changing size, and results show that PRR can precisely measure droplet refractive index, absolute size, as well as size change with absolute and relative errors within several nanometers and 0.6%, respectively, and thus PRR permits accurate measurements of transient droplet evaporation rates. The evaporations of flowing single n-nonane droplet and mono-dispersed n-heptane droplet stream are investigated by two PRR systems with a high speed linear CCD and a low speed array CCD, respectively. Their transient evaporation rates are experimentally determined and quantitatively agree well with the theoretical values predicted by classical Maxwell and Stefan-Fuchs models. With the demonstration of evaporation rate measurement of monocomponent droplet in this work, PRR is an ideal tool for measurements of transient droplet evaporation/condensation processes, and can be extended to multicomponent droplets in a wide range of industrially-relevant applications.

  20. Opportunities and barriers for smaller portions in food service: lessons from marketing and behavioral economics.

    Science.gov (United States)

    Riis, J

    2014-07-01

    This paper uses the frameworks and evidence from marketing and behavioral economics to highlight the opportunities and barriers for portion control in food service environments. Applying Kahneman's 'thinking fast and slow' concepts, it describes 10 strategies that can be effective in 'tricking' the consumer's fast cognitive system to make better decisions and in triggering the slow cognitive system to help prevent the fast system from making bad decisions. These strategies include shrinking defaults, elongating packages, increasing the visibility of small portions, offering more mixed virtue options, adding more small sizes, offering 'right-sized' standard portions, using meaningful size labels, adopting linear pricing, using temporal landmarks to push smaller portions and facilitating pre-commitment. For each of these strategies, I discuss the specific cost and revenue barriers that a food service operator would face if the strategy were adopted.

  1. Opportunities and barriers for smaller portions in food service: lessons from marketing and behavioral economics

    Science.gov (United States)

    Riis, J

    2014-01-01

    This paper uses the frameworks and evidence from marketing and behavioral economics to highlight the opportunities and barriers for portion control in food service environments. Applying Kahneman's ‘thinking fast and slow' concepts, it describes 10 strategies that can be effective in ‘tricking' the consumer's fast cognitive system to make better decisions and in triggering the slow cognitive system to help prevent the fast system from making bad decisions. These strategies include shrinking defaults, elongating packages, increasing the visibility of small portions, offering more mixed virtue options, adding more small sizes, offering ‘right-sized' standard portions, using meaningful size labels, adopting linear pricing, using temporal landmarks to push smaller portions and facilitating pre-commitment. For each of these strategies, I discuss the specific cost and revenue barriers that a food service operator would face if the strategy were adopted. PMID:25033960

  2. Measurements of bubble size spectra within leads in the Arctic summer pack ice

    Directory of Open Access Journals (Sweden)

    S. J. Norris

    2011-02-01

    Full Text Available The first measurements of bubble size spectra within the near-surface waters of open leads in the central Arctic pack ice were obtained during the Arctic Summer Cloud-Ocean Study (ASCOS in August 2008 at 87–87.6° N, 1–11° W. A significant number of small bubbles (30–100 μm diameter were present, with concentration decreasing rapidly with size from 100–560 μm; no bubbles larger than 560 μm were observed. The bubbles were present both during periods of low wind speed (U<6 m s−1 and when ice covered the surface of the lead. The low wind and short open-water fetch precludes production of bubbles by wave breaking suggesting that the bubbles are generated by processes below the surface. When the surface water was open to the atmosphere bubble concentrations increased with increasing heat loss to the atmosphere. The presence of substantial numbers of bubbles is significant because the bursting of bubbles at the surface provides a mechanism for the generation of aerosol and the ejection of biological material from the ocean into the atmosphere. Such a transfer has previously been proposed as a potential climate feedback linking marine biology and Arctic cloud properties.

  3. Measurement of Circumstellar Disk Sizes in the Upper Scorpius OB Association with ALMA

    Science.gov (United States)

    Barenfeld, Scott A.; Carpenter, John M.; Sargent, Anneila I.; Isella, Andrea; Ricci, Luca

    2017-12-01

    We present detailed modeling of the spatial distributions of gas and dust in 57 circumstellar disks in the Upper Scorpius OB Association observed with ALMA at submillimeter wavelengths. We fit power-law models to the dust surface density and CO J = 3–2 surface brightness to measure the radial extent of dust and gas in these disks. We found that these disks are extremely compact: the 25 highest signal-to-noise disks have a median dust outer radius of 21 au, assuming an {R}-1 dust surface density profile. Our lack of CO detections in the majority of our sample is consistent with these small disk sizes assuming the dust and CO share the same spatial distribution. Of seven disks in our sample with well-constrained dust and CO radii, four appear to be more extended in CO, although this may simply be due to the higher optical depth of the CO. Comparison of the Upper Sco results with recent analyses of disks in Taurus, Ophiuchus, and Lupus suggests that the dust disks in Upper Sco may be approximately three times smaller in size than their younger counterparts, although we caution that a more uniform analysis of the data across all regions is needed. We discuss the implications of these results for disk evolution.

  4. Physical Model for Rapid and Accurate Determination of Nanopore Size via Conductance Measurement.

    Science.gov (United States)

    Wen, Chenyu; Zhang, Zhen; Zhang, Shi-Li

    2017-10-27

    Nanopores have been explored for various biochemical and nanoparticle analyses, primarily via characterizing the ionic current through the pores. At present, however, size determination for solid-state nanopores is experimentally tedious and theoretically unaccountable. Here, we establish a physical model by introducing an effective transport length, L eff , that measures, for a symmetric nanopore, twice the distance from the center of the nanopore where the electric field is the highest to the point along the nanopore axis where the electric field falls to e -1 of this maximum. By [Formula: see text], a simple expression S 0 = f (G, σ, h, β) is derived to algebraically correlate minimum nanopore cross-section area S 0 to nanopore conductance G, electrolyte conductivity σ, and membrane thickness h with β to denote pore shape that is determined by the pore fabrication technique. The model agrees excellently with experimental results for nanopores in graphene, single-layer MoS 2 , and ultrathin SiN x films. The generality of the model is verified by applying it to micrometer-size pores.

  5. Size-dependent energy levels of InSb quantum dots measured by scanning tunneling spectroscopy.

    Science.gov (United States)

    Wang, Tuo; Vaxenburg, Roman; Liu, Wenyong; Rupich, Sara M; Lifshitz, Efrat; Efros, Alexander L; Talapin, Dmitri V; Sibener, S J

    2015-01-27

    The electronic structure of single InSb quantum dots (QDs) with diameters between 3 and 7 nm was investigated using atomic force microscopy (AFM) and scanning tunneling spectroscopy (STS). In this size regime, InSb QDs show strong quantum confinement effects which lead to discrete energy levels on both valence and conduction band states. Decrease of the QD size increases the measured band gap and the spacing between energy levels. Multiplets of equally spaced resonance peaks are observed in the tunneling spectra. There, multiplets originate from degeneracy lifting induced by QD charging. The tunneling spectra of InSb QDs are qualitatively different from those observed in the STS of other III-V materials, for example, InAs QDs, with similar band gap energy. Theoretical calculations suggest the electron tunneling occurs through the states connected with L-valley of InSb QDs rather than through states of the Γ-valley. This observation calls for better understanding of the role of indirect valleys in strongly quantum-confined III-V nanomaterials.

  6. Reproducibility of Ultrasound and Magnetic Resonance Imaging Measurements of Tendon Size

    International Nuclear Information System (INIS)

    Brushoej, C.; Henriksen, B.M.; Albrecht-Beste, E.; Hoelmich, P.; Larsen, K.; Bachmann Nielsen, M.

    2006-01-01

    Purpose: To investigate the intra- and inter-tester reproducibility of measurements of the Achilles tendon, tibialis anterior tendon, and the tibialis posterior tendon in football players using ultrasound (US) and magnetic resonance imaging (MRI). Material and Methods: Eleven asymptomatic football players were examined. Using a standardized US scanning protocol, the tendons were examined by two observers with US for thickness, width, and cross-sectional area. One observer conducted the procedure twice. The subjects also underwent an MRI examination, and the assessment of tendon size was conducted twice by two observers. Results: The best reproducibility judged by coefficient of variation (CV) and 95% confidence interval was determined for the Achilles tendon on both US and MRI. The variability of US on measurements on the tibialis anterior and tibialis posterior tendons was less than that when using MRI. In 12 out of 18 measurements, there were systematic differences between observers as judged by one-sided F-test. Conclusion: The reproducibility of the three tendons was limited. Precaution should be taken when looking for minor quantitative changes, i.e., training-induced hypertrophy, and when doing so, the Achilles tendon should be used

  7. Decoupling of size and shape fluctuations in heteropolymeric sequences reconciles discrepancies in SAXS vs. FRET measurements.

    Science.gov (United States)

    Fuertes, Gustavo; Banterle, Niccolò; Ruff, Kiersten M; Chowdhury, Aritra; Mercadante, Davide; Koehler, Christine; Kachala, Michael; Estrada Girona, Gemma; Milles, Sigrid; Mishra, Ankur; Onck, Patrick R; Gräter, Frauke; Esteban-Martín, Santiago; Pappu, Rohit V; Svergun, Dmitri I; Lemke, Edward A

    2017-08-01

    Unfolded states of proteins and native states of intrinsically disordered proteins (IDPs) populate heterogeneous conformational ensembles in solution. The average sizes of these heterogeneous systems, quantified by the radius of gyration ( R G ), can be measured by small-angle X-ray scattering (SAXS). Another parameter, the mean dye-to-dye distance ( R E ) for proteins with fluorescently labeled termini, can be estimated using single-molecule Förster resonance energy transfer (smFRET). A number of studies have reported inconsistencies in inferences drawn from the two sets of measurements for the dimensions of unfolded proteins and IDPs in the absence of chemical denaturants. These differences are typically attributed to the influence of fluorescent labels used in smFRET and to the impact of high concentrations and averaging features of SAXS. By measuring the dimensions of a collection of labeled and unlabeled polypeptides using smFRET and SAXS, we directly assessed the contributions of dyes to the experimental values R G and R E For chemically denatured proteins we obtain mutual consistency in our inferences based on R G and R E , whereas for IDPs under native conditions, we find substantial deviations. Using computations, we show that discrepant inferences are neither due to methodological shortcomings of specific measurements nor due to artifacts of dyes. Instead, our analysis suggests that chemical heterogeneity in heteropolymeric systems leads to a decoupling between R E and R G that is amplified in the absence of denaturants. Therefore, joint assessments of R G and R E combined with measurements of polymer shapes should provide a consistent and complete picture of the underlying ensembles.

  8. Accelerating inference for diffusions observed with measurement error and large sample sizes using approximate Bayesian computation

    DEFF Research Database (Denmark)

    Picchini, Umberto; Forman, Julie Lyng

    2016-01-01

    a nonlinear stochastic differential equation model observed with correlated measurement errors and an application to protein folding modelling. An approximate Bayesian computation (ABC)-MCMC algorithm is suggested to allow inference for model parameters within reasonable time constraints. The ABC algorithm......In recent years, dynamical modelling has been provided with a range of breakthrough methods to perform exact Bayesian inference. However, it is often computationally unfeasible to apply exact statistical methodologies in the context of large data sets and complex models. This paper considers...... applications. A simulation study is conducted to compare our strategy with exact Bayesian inference, the latter resulting two orders of magnitude slower than ABC-MCMC for the considered set-up. Finally, the ABC algorithm is applied to a large size protein data. The suggested methodology is fairly general...

  9. Neutral axis determination of full size concrete structures using coda wave measurements

    Science.gov (United States)

    Jiang, Hanwan; Zhan, Hanyu; Zhuang, Chenxu; Jiang, Ruinian

    2018-03-01

    Coda waves experiencing multiple scattering behaviors are sensitive to weak changes occurring in media. In this paper, a typical four-point bending test with varied external loads is conducted on a 30-meter T-beam that is removed from a bridge after being in service for 15 years, and the coda wave signals are collected with a couple of sources-receivers pairs. Then the observed coda waves at different loads are compared to calculate their relative velocity variations, which are utilized as the parameter to distinct the compression and tensile zones as well as determine the neutral axis position. Without any prior knowledge of the concrete beam, the estimated axis position agrees well with the associated strain gage measurement results, and the zones bearing stress and tension behaviors are indicated. The presented work offers significant potential for Non-Destructive Testing and Evaluation of full-size concrete structures in future work.

  10. Adductor magnus: An EMG investigation into proximal and distal portions and direction specific action.

    Science.gov (United States)

    Benn, Matthew L; Pizzari, Tania; Rath, Leanne; Tucker, Kylie; Semciw, Adam I

    2018-05-01

    Cadaveric studies indicate that adductor magnus is structurally partitioned into at least two regions. The aim of this study was to investigate the direction-specific actions of proximal and distal portions of adductor magnus, and in doing so determine if these segments have distinct functional roles. Fine-wire EMG electrodes were inserted into two portions of adductor magnus of 12 healthy young adults. Muscle activity was recorded during maximum voluntary isometric contractions (MVICs) across eight tests (hip flexion/extension, internal/external rotation, abduction, and adduction at 0°, 45°, and 90° hip flexion). Median activity within each action (normalized to peak) was compared between segments using repeated measures nonparametric tests (α = 0.05). An effect size (ES = z-score/√sample size) was calculated to determine the magnitude of difference between muscle segments. The relative contribution of each muscle segment differed significantly during internal rotation (P magnus has at least two functionally unique regions. Differences were most evident during rotation. The different direction-specific actions may imply that each segment performs separate roles in hip stability and movement. These findings may have implications on injury prevention and rehabilitation for adductor-related groin injuries, hamstring strain injury, and hip pathology. Clin. Anat. 31:535-543, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  11. Evaluation of Ventricle Size Measurements in Infants by Pediatric Emergency Medicine Physicians.

    Science.gov (United States)

    Halm, Brunhild M; Leone, Tina A; Chaudoin, Lindsey T; McKinley, Kenneth W; Ruzal-Shapiro, Carrie; Franke, Adrian A; Tsze, Daniel S

    2018-06-05

    The identification of hydrocephalus in infants by pediatric emergency medicine (PEM) physicians using cranial point-of-care ultrasound (POCUS) has not been evaluated. We aimed to conduct a pilot/proof-of-concept study to evaluate whether PEM physicians can identify hydrocephalus (anterior horn width >5 mm) in 15 infants (mean 69 ± 42 days old) from the neonatal intensive care unit using POCUS. Our exploratory aims were to determine the test characteristics of cranial POCUS performed by PEM physicians for diagnosing hydrocephalus and the interrater reliability between measurements made by the PEM physicians and the radiologist. Depending on the availability, 1 or 2 PEM physicians performed a cranial POCUS through the open anterior fontanel for each infant after a 30-minute didactic lecture to determine the size of the left and right ventricles by measuring the anterior horn width at the foramen of Monroe in coronal view. Within 1 week, an ultrasound (US) technologist performed a cranial US and a radiologist determined the ventricle sizes from the US images; these measurements were the criterion standard. A radiologist determined 12 of the 30 ventricles as hydrocephalic. The sensitivity and specificity of the PEM physicians performed cranial POCUS was 66.7% (95% confidence interval [CI], 34.9%-90.1%) and 94.4% (95% CI, 72.7%-99.9%), whereas the positive and negative predictive values were 88.9% (95% CI, 53.3%-98.2%) and 81.0% (95% CI, 65.5%-90.5%), respectively. The interrater reliability between the PEM physician's and radiologist's measurements was r = 0.91. The entire POCUS examinations performed by the PEM physicians took an average of 1.5 minutes. The time between the cranial POCUS and the radiology US was, on average, 4 days. While the PEM physicians in our study were able to determine the absence of hydrocephalus in infants with high specificity using cranial POCUS, there was insufficient evidence to support the use of this modality for identifying

  12. Measuring the sizes of nanospheres on a rough surface by using atomic force microscopy and a curvature-reconstruction method

    International Nuclear Information System (INIS)

    Oikawa, Koudai; Kim, Hyonchol; Watanabe, Naoya; Shigeno, Masatsugu; Shirakawabe, Yoshiharu; Yasuda, Kenji

    2007-01-01

    One of the advantages of atomic force microscopy (AFM) is that it can accurately measure the heights of targets on flat substrates. It is difficult, however, to determine the shape of nanoparticles on rough surfaces. We therefore propose a curvature-reconstruction method that estimates the sizes of particles by fitting sphere curvatures acquired from raw AFM data. We evaluated this fitting estimation using 15-, 30-, and 50-nm gold nanoparticles on mica and confirmed that particle sizes could be estimated within 5% from 20% of their curvature measured using a carbon nanotube (CNT) tip. We also estimated the sizes of nanoparticles on the rough surface of dried cells and found we also can estimate the size of those particles within 5%, which is difficult when we only used the height information. The results indicate the size of nanoparticles even on rough surfaces can be measured by using our method and a CNT tip

  13. A simple non-invasive method for measuring gross brain size in small live fish with semi-transparent heads

    Directory of Open Access Journals (Sweden)

    Joacim Näslund

    2014-09-01

    Full Text Available This paper describes a non-invasive method for estimating gross brain size in small fish with semi-transparent heads, using system camera equipment. Macro-photographs were taken from above on backlit free-swimming fish undergoing light anaesthesia. From the photographs, the width of the optic tectum was measured. This measure (TeO-measure correlates well with the width of the optic tectum as measured from out-dissected brains in both brown trout fry and zebrafish (Pearson r > 0.90. The TeO-measure also correlates well with overall brain wet weight in brown trout fry (r = 0.90, but less well for zebrafish (r = 0.79. A non-invasive measure makes it possible to quickly assess brain size from a large number of individuals, as well as repeatedly measuring brain size of live individuals allowing calculation of brain growth.

  14. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    Science.gov (United States)

    Atkinson, Dean B.; Pekour, Mikhail; Chand, Duli; Radney, James G.; Kolesar, Katheryn R.; Zhang, Qi; Setyan, Ari; O'Neill, Norman T.; Cappa, Christopher D.

    2018-04-01

    Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM1 and PM10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.

  15. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    Directory of Open Access Journals (Sweden)

    D. B. Atkinson

    2018-04-01

    Full Text Available Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM1 and PM10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.

  16. Depicted serving size: cereal packaging pictures exaggerate serving sizes and promote overserving.

    Science.gov (United States)

    Tal, Aner; Niemann, Stina; Wansink, Brian

    2017-02-06

    Extensive work has focused on the effects of nutrition label information on consumer behavior on the one hand, and on the effects of packaging graphics on the other hand. However, little work has examined how serving suggestion depictions - graphics relating to serving size - influence the quantity consumers serve themselves. The current work examines the prevalence of exaggerated serving size depictions on product packaging (study 1) and its effects on food serving in the context of cereal (study 2). Study 1 was an observational field survey of cereal packaging. Study 2 was a mixed experimental cross-sectional design conducted at a U.S. university, with 51 student participants. Study 1 coded 158 US breakfast cereals and compared the serving sizes depicted on the front of the box with the suggested serving size stated on the nutrition facts panel. Study 2 measured the amount of cereal poured from exaggerated or accurate serving size depictions. Study 1 compared average servings via t-tests. Study 2 used a mixed model with cereal type as the repeated measure and a compound symmetry covariance matrix. Study 1 demonstrated that portion size depictions on the front of 158 cereal boxes were 65.84% larger (221 vs. 134 calories) than the recommended portions on nutrition facts panels of those cereals. Study 2 showed that boxes that depicted exaggerated serving sizes led people to pour 20% more cereal compared to pouring from modified boxes that depicted a single-size portion of cereal matching suggested serving size. This was 45% over the suggested serving size. Biases in depicted serving size depicted on cereal packaging are prevalent in the marketplace. Such biases may lead to overserving, which may consequently lead to overeating. Companies should depict the recommended serving sizes, or otherwise indicate that the depicted portion represents an exaggerated serving size.

  17. Depicted serving size: cereal packaging pictures exaggerate serving sizes and promote overserving

    Directory of Open Access Journals (Sweden)

    Aner Tal

    2017-02-01

    Full Text Available Abstract Background Extensive work has focused on the effects of nutrition label information on consumer behavior on the one hand, and on the effects of packaging graphics on the other hand. However, little work has examined how serving suggestion depictions - graphics relating to serving size - influence the quantity consumers serve themselves. The current work examines the prevalence of exaggerated serving size depictions on product packaging (study 1 and its effects on food serving in the context of cereal (study 2. Methods Study 1 was an observational field survey of cereal packaging. Study 2 was a mixed experimental cross-sectional design conducted at a U.S. university, with 51 student participants. Study 1 coded 158 US breakfast cereals and compared the serving sizes depicted on the front of the box with the suggested serving size stated on the nutrition facts panel. Study 2 measured the amount of cereal poured from exaggerated or accurate serving size depictions. Study 1 compared average servings via t-tests. Study 2 used a mixed model with cereal type as the repeated measure and a compound symmetry covariance matrix. Results Study 1 demonstrated that portion size depictions on the front of 158 cereal boxes were 64.7% larger (221 vs. 134 calories than the recommended portions on nutrition facts panels of those cereals. Study 2 showed that boxes that depicted exaggerated serving sizes led people to pour 17.8% more cereal compared to pouring from modified boxes that depicted a single-size portion of cereal matching suggested serving size. This was 42% over the suggested serving size. Conclusions Biases in depicted serving size depicted on cereal packaging are prevalent in the marketplace. Such biases may lead to overserving, which may consequently lead to overeating. Companies should depict the recommended serving sizes, or otherwise indicate that the depicted portion represents an exaggerated serving size.

  18. A study on magnetic relaxation times of various organs and body fluids using superconducting magnetic resonance imaging system part I: measurement of relative signal intensity and T2 relaxation time in various portions of brain and cerebrospinal fluid

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Lee, Ghi Jai; Han, Moon Hee; Kim, Jae Ho; Han, Man Chang; Kim, Chu Wan

    1988-01-01

    This study was undertake to determine if routine clinical magnetic resonance imaging sequences using only two different repetition times (TRs) and with only two sequential echo times (TEs) can be used to measure reproducible relative signal intensity and T2 relaxation time for normal brain tissues and cerebrospinal fluid using a 2.0T superconducting system. In 47 patients 6 different anatomic sites were measured. For each anatomic location, the mean and standard deviation of these values were determined. On T1-weighted (SE 500msec/30msec) images, in globus pallidus and thalamus, of the CSF, cortical gray matter and retrobulbar fat tissue varied more, with a standard deviation of 11-14% on T1-weighted images. On T2-weighted (SE 3000msec/30msec and 3000msec/80msec) images, the relative signal intensity of all anatomic regions varied more than on T1-weighted images. The standard deviation of T2 relaxation times also varied from 10% (fat tissue) to 18% (CSF). These variations might be due to partial volume averaging, signal alteration of CSF secondary to CSF pulsatile motion, etc. Knowing that relative signal intensity and T2 relaxation times calculated from routine imaging sequences are reproducible in only limited area, these normal ranges can be used to investigate changes occurring in disease states of the limited regions.

  19. Minimal interference beam size/profile measurement techniques applicable to the Collider

    International Nuclear Information System (INIS)

    Nexsen, W.; Dutt, S.; Kauffmann, S.; Lebedev, V.; Maschke, A.; Mokhov, N.; Richardson, R.; Tsyganov, E.; Zinchenko, A.

    1993-05-01

    The imaging of synchrotron radiation (SR) has been suggested as a technique for providing a continuous, non-interfering monitor of the beam profile in the Collider rings at the Superconducting Super Collider. A closer examination has raised questions concerning the applicability of SR imaging in this case because of the diffraction broadening of the image, the requirements for axial space and location in the lattice, and the complexity of the system. We have surveyed the known, alternative, minimal interference techniques for measuring beam size and have evaluated them for possible Collider usage. We conclude that of the approaches that appear feasible, all require at least some development for our usage and that the development of an electron beam probe offers the best promise. We recommend that flying wires be used for cross-checking and calibrating the electron beam probe diagnostic and for luminosity measurements when the highest accuracy is required, but flying wires should not be used as the primary diagnostic because of their limited lifetime

  20. Measurement of the thickness of the sprayed nickel coatings on large-sized cast iron products

    Directory of Open Access Journals (Sweden)

    В. А. Сясько

    2016-11-01

    Full Text Available Modern industries increasingly use automatic spraying of heat-resistant Nickel  coating with a thickness  of      T = 1-3 mm for large-size parts made of cast iron with nodular graphite. The process of coating application is characterized by time-dependent behavior of its relative magnetic permeability, μс , that is a function of relaxation time, which can be as long as 24 hours, and by μс deviation from point to point on the surface. Aspects of eddy-current phase method for measuring the T value are considered. The structure of four- winding eddy current transformer transducers is described and results of calculation and optimization of their parameters are presented. The influence of controlled and interfering parameters is considered. Based  on the above results, a two-channel combined transducer is developed  providing measurement  error  of ΔТ ≤ ±(0.03T + 0.02 mm  in the shop environment in the process of coating application and in the final product check. Results of tests on reference specimens and of application in production processes are presented.

  1. Size Resolved Measurements of Springtime Aerosol Particles over the Northern South China Sea

    Science.gov (United States)

    Atwood, Samuel A.; Reid, Jeffrey S.; Kreidenweis, Sonia M.; Cliff, Stephen S.; Zhao, Yongjing; Lin, Neng-Huei; Tsay, Si-Chee; Chu, Yu-Chi; Westphal, Douglas L.

    2012-01-01

    Large sources of aerosol particles and their precursors are ubiquitous in East Asia. Such sources are known to impact the South China Sea (henceforth SCS), a sometimes heavily polluted region that has been suggested as particularly vulnerable to climate change. To help elucidate springtime aerosol transport into the SCS, an intensive study was performed on the remote Dongsha (aka Pratas) Islands Atoll in spring 2010. As part of this deployment, a Davis Rotating-drum Uniform size-cut Monitor (DRUM) cascade impactor was deployed to collect size-resolved aerosol samples at the surface that were analyzed by X-ray fluorescence for concentrations of selected elements. HYSPLIT backtrajectories indicated that the transport of aerosol observed at the surface at Dongsha was occurring primarily from regions generally to the north and east. This observation was consistent with the apparent persistence of pollution and dust aerosol, along with sea salt, in the ground-based dataset. In contrast to the sea-level observations, modeled aerosol transport suggested that the westerly flow aloft (w700 hPa) transported smoke-laden air toward the site from regions from the south and west. Measured aerosol optical depth at the site was highest during time periods of modeled heavy smoke loadings aloft. These periods did not coincide with elevated aerosol concentrations at the surface, although the model suggested sporadic mixing of this free-tropospheric aerosol to the surface over the SCS. A biomass burning signature was not clearly identified in the surface aerosol composition data, consistent with this aerosol type remaining primarily aloft and not mixing strongly to the surface during the study. Significant vertical wind shear in the region also supports the idea that different source regions lead to varying aerosol impacts in different vertical layers, and suggests the potential for considerable vertical inhomogeneity in the SCS aerosol environment.

  2. Stability measures for rolling schedules with applications to capacity expansion planning, master production scheduling, and lot sizing

    OpenAIRE

    Kimms, Alf

    1996-01-01

    This contribution discusses the measurement of (in-)stability of finite horizon production planning when done on a rolling horizon basis. As examples we review strategic capacity expansion planning, tactical master production schedulng, and operational capacitated lot sizing.

  3. Confounding compression: the effects of posture, sizing and garment type on measured interface pressure in sports compression clothing.

    Science.gov (United States)

    Brophy-Williams, Ned; Driller, Matthew William; Shing, Cecilia Mary; Fell, James William; Halson, Shona Leigh; Halson, Shona Louise

    2015-01-01

    The purpose of this investigation was to measure the interface pressure exerted by lower body sports compression garments, in order to assess the effect of garment type, size and posture in athletes. Twelve national-level boxers were fitted with sports compression garments (tights and leggings), each in three different sizes (undersized, recommended size and oversized). Interface pressure was assessed across six landmarks on the lower limb (ranging from medial malleolus to upper thigh) as athletes assumed sitting, standing and supine postures. Sports compression leggings exerted a significantly higher mean pressure than sports compression tights (P sports compression garments is significantly affected by garment type, size and posture assumed by the wearer.

  4. Analysis of point source size on measurement accuracy of lateral point-spread function of confocal Raman microscopy

    Science.gov (United States)

    Fu, Shihang; Zhang, Li; Hu, Yao; Ding, Xiang

    2018-01-01

    Confocal Raman Microscopy (CRM) has matured to become one of the most powerful instruments in analytical science because of its molecular sensitivity and high spatial resolution. Compared with conventional Raman Microscopy, CRM can perform three dimensions mapping of tiny samples and has the advantage of high spatial resolution thanking to the unique pinhole. With the wide application of the instrument, there is a growing requirement for the evaluation of the imaging performance of the system. Point-spread function (PSF) is an important approach to the evaluation of imaging capability of an optical instrument. Among a variety of measurement methods of PSF, the point source method has been widely used because it is easy to operate and the measurement results are approximate to the true PSF. In the point source method, the point source size has a significant impact on the final measurement accuracy. In this paper, the influence of the point source sizes on the measurement accuracy of PSF is analyzed and verified experimentally. A theoretical model of the lateral PSF for CRM is established and the effect of point source size on full-width at half maximum of lateral PSF is simulated. For long-term preservation and measurement convenience, PSF measurement phantom using polydimethylsiloxane resin, doped with different sizes of polystyrene microspheres is designed. The PSF of CRM with different sizes of microspheres are measured and the results are compared with the simulation results. The results provide a guide for measuring the PSF of the CRM.

  5. Beak measurements of octopus ( Octopus variabilis) in Jiaozhou Bay and their use in size and biomass estimation

    Science.gov (United States)

    Xue, Ying; Ren, Yiping; Meng, Wenrong; Li, Long; Mao, Xia; Han, Dongyan; Ma, Qiuyun

    2013-09-01

    Cephalopods play key roles in global marine ecosystems as both predators and preys. Regressive estimation of original size and weight of cephalopod from beak measurements is a powerful tool of interrogating the feeding ecology of predators at higher trophic levels. In this study, regressive relationships among beak measurements and body length and weight were determined for an octopus species ( Octopus variabilis), an important endemic cephalopod species in the northwest Pacific Ocean. A total of 193 individuals (63 males and 130 females) were collected at a monthly interval from Jiaozhou Bay, China. Regressive relationships among 6 beak measurements (upper hood length, UHL; upper crest length, UCL; lower hood length, LHL; lower crest length, LCL; and upper and lower beak weights) and mantle length (ML), total length (TL) and body weight (W) were determined. Results showed that the relationships between beak size and TL and beak size and ML were linearly regressive, while those between beak size and W fitted a power function model. LHL and UCL were the most useful measurements for estimating the size and biomass of O. variabilis. The relationships among beak measurements and body length (either ML or TL) were not significantly different between two sexes; while those among several beak measurements (UHL, LHL and LBW) and body weight (W) were sexually different. Since male individuals of this species have a slightly greater body weight distribution than female individuals, the body weight was not an appropriate measurement for estimating size and biomass, especially when the sex of individuals in the stomachs of predators was unknown. These relationships provided essential information for future use in size and biomass estimation of O. variabilis, as well as the estimation of predator/prey size ratios in the diet of top predators.

  6. Incorporating Plutonium Particle Size Effects in the Assessment of Active Mode Measurement Uncertainty in Passive-Active Neutron Radioassay Systems

    International Nuclear Information System (INIS)

    Blackwood, Larry G.; Harker, Yale D.

    2002-01-01

    Assessment of active mode measurement uncertainty in passive-active neutron radioassay systems used to measure Pu content in nuclear waste is severely hampered by lack of knowledge of the waste Pu particle size distribution, which is a major factor in determining bias in active mode measurements. The sensitivity of active mode measurements to particle size precludes using simulations or surrogate waste forms to estimate uncertainty in active mode measurements when the particle size distribution is not precisely known or inadequately reproduced. An alternative approach is based on a statistical comparison of active and passive mode results in the mass range for which both active and passive mode analyses produce useable measurements. Because passive mode measurements are not particularly sensitive to particle size effects, their uncertainty can be more easily assessed. Once bias corrected, passive mode measurements can serve as confirmatory measurements for the estimation of active mode bias. Further statistical analysis of the errors in measurements leads to precision estimates for the active mode

  7. Electron-phonon scattering in indium from r.f. size effect measurements

    International Nuclear Information System (INIS)

    Hoff, A.B.M.

    1977-01-01

    The anisotropy of the electron-phonon collison frequency on the second and third zone Fermi surfaces of indium has been determined from the temperature dependence of radiofrequency size effect (R.F.S.E.) line amplitudes. The orbitally-averaged scattering rates turn out to vary with temperature T according to a T 3 -dependence over the entire Fermi surface, except for orbits on the hole surface close to the (100) and (001) symmetry planes. The anomalous temperatue dependences found in the experiments could be attributed to the special circumstances under which the R.F.S.E. was observed. The influences of both the scattering effectiveness and the multiple turns of the electrons on the observed temperature dependence are discussed extensively. For a large number of extreme orbits on the second and third zone Fermi surfaces, the average scattering rates were measured. In order to obtain a functional expression for the local collision frequency over the entire Fermi surface, an inversion technique was used. As a result, it was found that the anisotropy of the collision frequency over the second zone surface is quite high (1:20) whereas the anisotropy over the third zone surface is rather small (<20%). Further, the variation of the scattering rate round the [111]-point on the hole surface could be confirmed by the results of limiting point measurements. The experimental scattering rates at several points on the Fermi surface were compared with theoretical values obtained from a simple two-OPW model calculation. The calculated anisotropy agrees roughly with the experimental one, although locally the actual values can differ by a factor of 2 or more

  8. Measurements of size and composition of particles in polar stratospheric clouds from infrared solar absorption spectra

    International Nuclear Information System (INIS)

    Kinne, S.; Toon, O.B.; Toon, G.C.; Farmer, C.B.; Browell, E.V.; McCormick, M.P.

    1989-01-01

    The attenuation of solar radiation between 1.8- and 15-μm wavelength was measured with the airborne Jet Propulsion Laboratory Mark IV interferometer during the Airborne Antarctic Ozone Expedition in 1987. The measurements not only provide information about the abundance of stratospheric gases, but also about the optical depths of polar stratospheric clouds (PSCs) at wavelengths of negligible gas absorption. The spectral dependence of the PSC optical depth contains information about PSC particle size and particle composition. Thirty-three PSC cases were analyzed and categorized into two types. Type I clouds contain particles with radii of about 0.5 μm and nitric acid concentrations greater than 40%. Type II clouds contain particles composed of water ice with radii of 6 μm and larger. Cloud altitudes were determined from 1.064-μm backscattering observations of the airborne Langley DIAL lidar system. Based on the PSC geometrical thickness, both mass and particle density were estimated. Type I clouds typically had visible wavelength optical depths of about 0.008, mass densities of about 20 ppb, and about 2 particles/cm 3 . The observed type II clouds had optical depths of about 0.03, mass densities of about 400 ppb mass, and about 0.03 particles/cm 3 . The detected PSC type I clouds extended to altitudes of 21 km and were nearly in the ozone-depleted region of the polar stratosphere. The observed type II cases during September were predominantly found at altitudes below 15 km

  9. Melt-Pool Temperature and Size Measurement During Direct Laser Sintering

    Energy Technology Data Exchange (ETDEWEB)

    List, III, Frederick Alyious [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dinwiddie, Ralph Barton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Carver, Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gockel, Joy E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    Additive manufacturing has demonstrated the ability to fabricate complex geometries and components not possible with conventional casting and machining. In many cases, industry has demonstrated the ability to fabricate complex geometries with improved efficiency and performance. However, qualification and certification of processes is challenging, leaving companies to focus on certification of material though design allowable based approaches. This significantly reduces the business case for additive manufacturing. Therefore, real time monitoring of the melt pool can be used to detect the development of flaws, such as porosity or un-sintered powder and aid in the certification process. Characteristics of the melt pool in the Direct Laser Sintering (DLS) process is also of great interest to modelers who are developing simulation models needed to improve and perfect the DLS process. Such models could provide a means to rapidly develop the optimum processing parameters for new alloy powders and optimize processing parameters for specific part geometries. Stratonics’ ThermaViz system will be integrated with the Renishaw DLS system in order to demonstrate its ability to measure melt pool size, shape and temperature. These results will be compared with data from an existing IR camera to determine the best approach for the determination of these critical parameters.

  10. Atomic force microscopy measurements of bacterial adhesion and biofilm formation onto clay-sized particles

    Science.gov (United States)

    Huang, Qiaoyun; Wu, Huayong; Cai, Peng; Fein, Jeremy B.; Chen, Wenli

    2015-01-01

    Bacterial adhesion onto mineral surfaces and subsequent biofilm formation play key roles in aggregate stability, mineral weathering, and the fate of contaminants in soils. However, the mechanisms of bacteria-mineral interactions are not fully understood. Atomic force microscopy (AFM) was used to determine the adhesion forces between bacteria and goethite in water and to gain insight into the nanoscale surface morphology of the bacteria-mineral aggregates and biofilms formed on clay-sized minerals. This study yields direct evidence of a range of different association mechanisms between bacteria and minerals. All strains studied adhered predominantly to the edge surfaces of kaolinite rather than to the basal surfaces. Bacteria rarely formed aggregates with montmorillonite, but were more tightly adsorbed onto goethite surfaces. This study reports the first measured interaction force between bacteria and a clay surface, and the approach curves exhibited jump-in events with attractive forces of 97 ± 34 pN between E. coli and goethite. Bond strengthening between them occurred within 4 s to the maximum adhesion forces and energies of −3.0 ± 0.4 nN and −330 ± 43 aJ (10−18 J), respectively. Under the conditions studied, bacteria tended to form more extensive biofilms on minerals under low rather than high nutrient conditions. PMID:26585552

  11. Colony size measurement of the yeast gene deletion strains for functional genomics

    Directory of Open Access Journals (Sweden)

    Mir-Rashed Nadereh

    2007-04-01

    Full Text Available Abstract Background Numerous functional genomics approaches have been developed to study the model organism yeast, Saccharomyces cerevisiae, with the aim of systematically understanding the biology of the cell. Some of these techniques are based on yeast growth differences under different conditions, such as those generated by gene mutations, chemicals or both. Manual inspection of the yeast colonies that are grown under different conditions is often used as a method to detect such growth differences. Results Here, we developed a computerized image analysis system called Growth Detector (GD, to automatically acquire quantitative and comparative information for yeast colony growth. GD offers great convenience and accuracy over the currently used manual growth measurement method. It distinguishes true yeast colonies in a digital image and provides an accurate coordinate oriented map of the colony areas. Some post-processing calculations are also conducted. Using GD, we successfully detected a genetic linkage between the molecular activity of the plant-derived antifungal compound berberine and gene expression components, among other cellular processes. A novel association for the yeast mek1 gene with DNA damage repair was also identified by GD and confirmed by a plasmid repair assay. The results demonstrate the usefulness of GD for yeast functional genomics research. Conclusion GD offers significant improvement over the manual inspection method to detect relative yeast colony size differences. The speed and accuracy associated with GD makes it an ideal choice for large-scale functional genomics investigations.

  12. An Ultra-Sensitive, Size Resolved Particle Mass Measurement Device, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — By providing size resolved compositional information, the Aerosol Mass Spectrometer (AMS) has greatly advanced understanding of aircraft particulate matter (PM)...

  13. An Ultra-Sensitive, Size Resolved Particle Mass Measurement Device, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The characterization of aircraft particulate matter (PM) emissions has benefited greatly by the Aerosol Mass Spectrometer (AMS) by providing size resolved...

  14. Simulation of the measure of the microparticle size distribution in two dimensions

    International Nuclear Information System (INIS)

    Lameiras, F.S.; Silva Neto, P.P. da

    1987-01-01

    For the nuclear ceramic industry, the determination of the porous size distribution is very important to predict the dimensional thermal stability of uranium dioxide sintered pellets. The determination of the grain size distribution is still very important to predict the operation behavior of these pellets, as well as to control the fabrication process. The Saltykov method is commonly used to determine the microparticles size distribution. A simulation for two-dimensions, using this method and the size distribution of cords to calculate the area distribution [pt

  15. A liposome-based size calibration method for measuring microvesicles by flow cytometry

    DEFF Research Database (Denmark)

    Simonsen, Jens Bæk

    2016-01-01

    BACKGROUND: Over the last years the need for a gold standard to determine the sizes of extracellular vesicles including microvesicles by flow cytometry has been emphasized. METHODS: This work suggests to use artificial vesicles as calibrators to ascertain the size of microvesicles from the side...

  16. Effect-Size Measures and Meta-Analytic Thinking in Counseling Psychology Research

    Science.gov (United States)

    Henson, Robin K.

    2006-01-01

    Effect sizes are critical to result interpretation and synthesis across studies. Although statistical significance testing has historically dominated the determination of result importance, modern views emphasize the role of effect sizes and confidence intervals. This article accessibly discusses how to calculate and interpret the effect sizes…

  17. Reassessment of genome size in turtle and crocodile based on chromosome measurement by flow karyotyping: close similarity to chicken

    Science.gov (United States)

    Kasai, Fumio; O'Brien, Patricia C. M.; Ferguson-Smith, Malcolm A.

    2012-01-01

    The genome size in turtles and crocodiles is thought to be much larger than the 1.2 Gb of the chicken (Gallus gallus domesticus, GGA), according to the animal genome size database. However, GGA macrochromosomes show extensive homology in the karyotypes of the red eared slider (Trachemys scripta elegans, TSC) and the Nile crocodile (Crocodylus niloticus, CNI), and bird and reptile genomes have been highly conserved during evolution. In this study, size and GC content of all chromosomes are measured from the flow karyotypes of GGA, TSC and CNI. Genome sizes estimated from the total chromosome size demonstrate that TSC and CNI are 1.21 Gb and 1.29 Gb, respectively. This refines previous overestimations and reveals similar genome sizes in chicken, turtle and crocodile. Analysis of chromosome GC content in each of these three species shows a higher GC content in smaller chromosomes than in larger chromosomes. This contrasts with mammals and squamates in which GC content does not correlate with chromosome size. These data suggest that a common ancestor of birds, turtles and crocodiles had a small genome size and a chromosomal size-dependent GC bias, distinct from the squamate lineage. PMID:22491763

  18. A novel system for rapid measurement of high-frequency magnetic properties of toroidal cores of different sizes

    CERN Document Server

    Derebasi, N; Moses, A J; Fox, D

    2000-01-01

    A novel system for power loss and B-H measurements on toroidal magnetic cores was built to operate up to 200 kHz. Measurement data taken using sophisticated software at 10 MHz sampling rate and 16-bit resolution shows the system is versatile and can be used to test a wide range of core sizes and materials with an error <+-3%.

  19. Use of a microvideo probe to measure the size and velocity of water droplets in EDF steam turbines

    International Nuclear Information System (INIS)

    Courant, J.J.; Heurtebise, F.; Kleitz, A.

    1992-09-01

    Owing to the necessity to protect equipment associated with power plant turbines using saturated steam and following verification of the turbine design codes, EDF has developed a probe specifically designed for velocimetric and particle size grading measurements in this 2-phase environment. This method is also suitable for the measurement of cold or incandescent solid particles entrained in gas. (authors). 8 figs., 3 refs

  20. Use of statistical models based on radiographic measurements to predict oviposition date and clutch size in rock iguanas (Cyclura nubila)

    International Nuclear Information System (INIS)

    Alberts, A.C.

    1995-01-01

    The ability to noninvasively estimate clutch size and predict oviposition date in reptiles can be useful not only to veterinary clinicians but also to managers of captive collections and field researchers. Measurements of egg size and shape, as well as position of the clutch within the coelomic cavity, were taken from diagnostic radiographs of 20 female Cuban rock iguanas, Cyclura nubila, 81 to 18 days prior to laying. Combined with data on maternal body size, these variables were entered into multiple regression models to predict clutch size and timing of egg laying. The model for clutch size was accurate to 0.53 ± 0.08 eggs, while the model for oviposition date was accurate to 6.22 ± 0.81 days. Equations were generated that should be applicable to this and other large Cyclura species. © 1995 Wiley-Liss, Inc

  1. Size measuring techniques as tool to monitor pea proteins intramolecular crosslinking by transglutaminase treatment.

    Science.gov (United States)

    Djoullah, Attaf; Krechiche, Ghali; Husson, Florence; Saurel, Rémi

    2016-01-01

    In this work, techniques for monitoring the intramolecular transglutaminase cross-links of pea proteins, based on protein size determination, were developed. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis profiles of transglutaminase-treated low concentration (0.01% w/w) pea albumin samples, compared to the untreated one (control), showed a higher electrophoretic migration of the major albumin fraction band (26 kDa), reflecting a decrease in protein size. This protein size decrease was confirmed, after DEAE column purification, by dynamic light scattering (DLS) where the hydrodynamic radius of treated samples appears to be reduced compared to the control one. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Just Enough for You: About Food Portions

    Science.gov (United States)

    ... U.S. Food and Drug Administration (FDA) changed some food and beverage serving sizes so that labels more closely match ... fructose or glucose , that have been added to food and beverages. Fruit and milk contain naturally-occurring sugars and ...

  3. Analysis of tecniques for measurement of the size distribution of solid particles

    Directory of Open Access Journals (Sweden)

    F. O. Arouca

    2005-03-01

    Full Text Available Determination of the size distribution of solid particles is fundamental for analysis of the performance several pieces of equipment used for solid-fluid separation. The main objective of this work is to compare the results obtained with two traditional methods for determination of the size grade distribution of powdery solids: the gamma-ray attenuation technique (GRAT and the LADEQ test tube technique. The effect of draining the suspension in the two techniques used was also analyzed. The GRAT can supply the particle size distribution of solids through the monitoring of solid concentration in experiments on batch settling of diluted suspensions. The results show that use of the peristaltic pump in the GRAT and the LADEQ methods produced a significant difference between the values obtained for the parameters of the particle size model.

  4. Application of carbon extraction replicas in grain-size measurements of high-strength steels using TEM

    International Nuclear Information System (INIS)

    Poorhaydari, Kioumars; Ivey, Douglas G.

    2007-01-01

    In this paper, the application of carbon extraction replicas in grain-size measurements is introduced and discussed. Modern high-strength microalloyed steels, used as structural or pipeline materials, have very small grains with substructures. Replicas used in transmission electron microscopes can resolve the grain boundaries and can be used for systematic measurement of grain size in cases where the small size of the grains pushes the resolution of conventional optical microscopes. The grain-size variations obtained from replicas are compared with those obtained from optical and scanning electron microscopy. An emphasis is placed on the importance of using the correct technique for imaging and the optimal magnification. Grain-size measurements are used for estimation of grain-boundary strengthening contribution to yield strength. The variation in grain size is also correlated with hardness in the base metal of several microalloyed steels, as well as the fine-grained heat-affected zone of a weld structure with several heat inputs

  5. Aerosol size and chemical composition measurements at the Polar Environment Atmospheric Research Lab (PEARL) in Eureka, Nunavut

    Science.gov (United States)

    Hayes, P. L.; Tremblay, S.; Chang, R. Y. W.; Leaitch, R.; Kolonjari, F.; O'Neill, N. T.; Chaubey, J. P.; AboEl Fetouh, Y.; Fogal, P.; Drummond, J. R.

    2016-12-01

    This study presents observations of aerosol chemical composition and particle number size distribution at the Polar Environment Atmospheric Research Laboratory (PEARL) in the Canadian High Arctic (80N, 86W). The current aerosol measurement program at PEARL has been ongoing for more than a year providing long-term observations of Arctic aerosol size distributions for both coarse and fine modes. Particle nucleation events were frequently observed during the summers of 2015 and 2016. The size distribution data are also compared against similar measurements taken at the Alert Global Atmospheric Watch Observatory (82N, 62W) for July and August 2015. The nucleation events are correlated at the two sites, despite a distance of approximately 500 km, suggesting regional conditions favorable for particle nucleation and growth during this period. Size resolved chemical composition measurements were also carried out using an aerosol mass spectrometer. The smallest measured particles between 40 and 60 nm are almost entirely organic aerosol (OA) indicating that the condensation of organic vapors is responsible for particle growth events and possibly particle nucleation. This conclusion is further supported by the relatively high oxygen content of the OA, which is consistent with secondary formation of OA via atmospheric oxidation.Lastly, surface measurements of the aerosol scattering coefficient are compared against the coefficient values calculated using Mie theory and the measured aerosol size distribution. Both the actual and the calculated scattering coefficients are then compared to sun photometer measurements to understand the relationship between surface and columnar aerosol optical properties. The measurements at PEARL provide a unique combination of surface and columnar data sets on aerosols in the High Arctic, a region where such measurements are scarce despite the important impact of aerosols on Arctic climate.PEARL research is supported by the Natural Sciences and

  6. Flash X-Ray (FXR) Accelerator Optimization Electronic Time-Resolved Measurement of X-Ray Source Size

    International Nuclear Information System (INIS)

    Jacob, J; Ong, M; Wargo, P

    2005-01-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating various approaches to minimize the x-ray source size on the Flash X-Ray (FXR) linear induction accelerator in order to improve x-ray flux and increase resolution for hydrodynamic radiography experiments. In order to effectively gauge improvements to final x-ray source size, a fast, robust, and accurate system for measuring the spot size is required. Timely feedback on x-ray source size allows new and improved accelerator tunes to be deployed and optimized within the limited run-time constraints of a production facility with a busy experimental schedule; in addition, time-resolved measurement capability allows the investigation of not only the time-averaged source size, but also the evolution of the source size, centroid position, and x-ray dose throughout the 70 ns beam pulse. Combined with time-resolved measurements of electron beam parameters such as emittance, energy, and current, key limiting factors can be identified, modeled, and optimized for the best possible spot size. Roll-bar techniques are a widely used method for x-ray source size measurement, and have been the method of choice at FXR for many years. A thick bar of tungsten or other dense metal with a sharp edge is inserted into the path of the x-ray beam so as to heavily attenuate the lower half of the beam, resulting in a half-light, half-dark image as seen downstream of the roll-bar; by measuring the width of the transition from light to dark across the edge of the roll-bar, the source size can be deduced. For many years, film has been the imaging medium of choice for roll-bar measurements thanks to its high resolution, linear response, and excellent contrast ratio. Film measurements, however, are fairly cumbersome and require considerable setup and analysis time; moreover, with the continuing trend towards all-electronic measurement systems, film is becoming increasingly difficult and expensive to procure. Here, we shall

  7. Rapid Measurements of Aerosol Size Distribution and Hygroscopic Growth via Image Processing with a Fast Integrated Mobility Spectrometer (FIMS)

    Science.gov (United States)

    Wang, Y.; Pinterich, T.; Spielman, S. R.; Hering, S. V.; Wang, J.

    2017-12-01

    Aerosol size distribution and hygroscopicity are among key parameters in determining the impact of atmospheric aerosols on global radiation and climate change. In situ submicron aerosol size distribution measurements commonly involve a scanning mobility particle sizer (SMPS). The SMPS scanning time is in the scale of minutes, which is often too slow to capture the variation of aerosol size distribution, such as for aerosols formed via nucleation processes or measurements onboard research aircraft. To solve this problem, a Fast Integrated Mobility Spectrometer (FIMS) based on image processing was developed for rapid measurements of aerosol size distributions from 10 to 500 nm. The FIMS consists of a parallel plate classifier, a condenser, and a CCD detector array. Inside the classifier an electric field separates charged aerosols based on electrical mobilities. Upon exiting the classifier, the aerosols pass through a three stage growth channel (Pinterich et al. 2017; Spielman et al. 2017), where aerosols as small as 7 nm are enlarged to above 1 μm through water or heptanol condensation. Finally, the grown aerosols are illuminated by a laser sheet and imaged onto a CCD array. The images provide both aerosol concentration and position, which directly relate to the aerosol size distribution. By this simultaneous measurement of aerosols with different sizes, the FIMS provides aerosol size spectra nearly 100 times faster than the SMPS. Recent deployment onboard research aircraft demonstrated that the FIMS is capable of measuring aerosol size distributions in 1s (Figure), thereby offering a great advantage in applications requiring high time resolution (Wang et al. 2016). In addition, the coupling of the FIMS with other conventional aerosol instruments provides orders of magnitude more rapid characterization of aerosol optical and microphysical properties. For example, the combination of a differential mobility analyzer, a relative humidity control unit, and a FIMS was

  8. Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Jeong [Hallym University College of Medicine, Department of Radiology, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of); Yoon, Dae Young; Lee, Hyung Jin [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Kim, Eun Soo [Hallym University College of Medicine, Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, Gyeonggi-do (Korea, Republic of); Jeon, Hong Jun; Lee, Jong Young; Cho, Byung-Moon [Hallym University College of Medicine, Department of Neurosurgery, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2017-05-15

    Accurate and reliable measurement of aneurysm size is important for treatment planning. The purpose of this study was to determine intraobserver and interobserver variability of CTA and MRA for measurement of the size of cerebral aneurysms. Thirty patients with 33 unruptured cerebral aneurysms (saccular, >3 mm in their maximal dimension, with no daughter sacs or lobulations) who underwent 256-row multislice CTA, 3-D TOF MRA at 3.0T, and 3D rotational angiography (3DRA) were retrospectively analyzed. Three independent observers measured the neck, height, and width of the aneurysms using the CTA and MRA images. Intraobserver and interobserver variability of CTA and MRA measurements was evaluated using the standardized difference and intraclass correlation coefficient, with 3DRA measurements as the reference standard. In addition, the mean values of the measurements using CTA and MRA were compared with those using 3DRA. The overall intraobserver and interobserver standardized differences in CTA/MRA were 12.83-15.92%/13.48-17.45% and 14.08-17.00%/12.08-17.67%, respectively. The overall intraobserver and interobserver intraclass correlation coefficients of CTA/MRA were 0.88-0.98/0.84-0.96 and 0.86-0.98/0.85-0.95, respectively. Compared to the height and width measurements, measurements of the neck dimensions showed higher intraobserver and interobserver variability. The sizes of the cerebral aneurysms measured by CTA and MRA were 1.13-9.26 and 5.20-9.67% larger than those measured by 3DRA, respectively; however, these differences were not statistically significant. There were no noticeable differences between intraobserver and interobserver variability for both CTA- and MRA-based measurements of the size of cerebral aneurysms. (orig.)

  9. Determining the Variability of Lesion Size Measurements from CT Patient Data Sets Acquired under “No Change” Conditions

    Directory of Open Access Journals (Sweden)

    Michael F. McNitt-Gray

    2015-02-01

    Full Text Available PURPOSE: To determine the variability of lesion size measurements in computed tomography data sets of patients imaged under a “no change” (“coffee break” condition and to determine the impact of two reading paradigms on measurement variability. METHOD AND MATERIALS: Using data sets from 32 non-small cell lung cancer patients scanned twice within 15 minutes (“no change”, measurements were performed by five radiologists in two phases: (1 independent reading of each computed tomography dataset (timepoint: (2 a locked, sequential reading of datasets. Readers performed measurements using several sizing methods, including one-dimensional (1D longest in-slice dimension and 3D semi-automated segmented volume. Change in size was estimated by comparing measurements performed on both timepoints for the same lesion, for each reader and each measurement method. For each reading paradigm, results were pooled across lesions, across readers, and across both readers and lesions, for each measurement method. RESULTS: The mean percent difference (±SD when pooled across both readers and lesions for 1D and 3D measurements extracted from contours was 2.8 ± 22.2% and 23.4 ± 105.0%, respectively, for the independent reads. For the locked, sequential reads, the mean percent differences (±SD reduced to 2.52 ± 14.2% and 7.4 ± 44.2% for the 1D and 3D measurements, respectively. CONCLUSION: Even under a “no change” condition between scans, there is variation in lesion size measurements due to repeat scans and variations in reader, lesion, and measurement method. This variation is reduced when using a locked, sequential reading paradigm compared to an independent reading paradigm.

  10. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    Science.gov (United States)

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  11. Influence of size and surface structure of microparticles on accuracy of measurements of its uranium isotopic composition

    International Nuclear Information System (INIS)

    Stebelkov, V.; Kolesnikov, O.; Moulenko, D.; Sokolov, A.; Pavlov, A.; Simakin, S.

    2002-01-01

    Full text: One of the elements of the scheme for complex analysis of environmental samples, collected in the regions of location of nuclear facilities, is mass-spectrometry of microparticles of nuclear materials implemented for determination of isotopic composition of these materials. Widely used technique of mass-spectrometry of particles is secondary ion mass-spectrometry. This technique is characterized by successive acquisition of ions from different isotopes under gradual sputtering of microparticle during analysis. The purpose of this work was investigation of kinetic of size changing and changing of measured values of uranium-235 concentration as well as investigation of influence of size and surface structure of microparticle on measurement results. Method of investigation had been comprised to several sequential measurements of uranium isotopes content in the same particle and photography of this particle before every sequential measurement by using electron microscope. Analysis of each particle was finished when this particle was fully sputtered. There were investigated 33 particles of irregular shape and initial sizes from 0.5 μm to 3.5 μm. These particles had different types of surface structure and different isotopic composition. Besides there were investigated 22 spherical particles of UO 2 with 3.7% uranium-235 abundance with sizes from 0.7 μm to 2.4 μm. Thirteen particles of irregular shape were sputtered fully during first measurement of isotopic composition. Two sequential measurements were implemented for 12 particles, three sequential measurements were implemented for 7 particles. For 2 particles of sizes 3.5 μm x 2 μm and 1.2 μm there were implemented four sequential measurements of isotopic composition. During these investigations it was determined that the number of sequential measurements depends not only on size but also on surface structure of particle. With rare exception the sequential values of concentrations of uranium-235

  12. Size-based hydroacoustic measures of within-season fish abundance in a boreal freshwater ecosystem.

    Directory of Open Access Journals (Sweden)

    Riley A Pollom

    Full Text Available Eleven sequential size-based hydroacoustic surveys conducted with a 200 kHz split-beam transducer during the summers of 2011 and 2012 were used to quantify seasonal declines in fish abundance in a boreal reservoir in Manitoba, Canada. Fish densities were sufficiently low to enable single target resolution and tracking. Target strengths converted to log2-based size-classes indicated that smaller fish were consistently more abundant than larger fish by a factor of approximately 3 for each halving of length. For all size classes, in both years, abundance (natural log declined linearly over the summer at rates that varied from -0.067 x day(-1 for the smallest fish to -0.016 x day(-1 for the largest (R2 = 0.24-0.97. Inter-annual comparisons of size-based abundance suggested that for larger fish (>16 cm, mean winter decline rates were an order of magnitude lower (-0.001 x day(-1 and overall survival higher (71% than in the main summer fishing season (mean loss rate -0.038 x day(-1; survival 33%. We conclude that size-based acoustic survey methods have the potential to assess within-season fish abundance dynamics, and may prove useful in long-term monitoring of productivity and hence management of boreal aquatic ecosystems.

  13. Size-based hydroacoustic measures of within-season fish abundance in a boreal freshwater ecosystem.

    Science.gov (United States)

    Pollom, Riley A; Rose, George A

    2015-01-01

    Eleven sequential size-based hydroacoustic surveys conducted with a 200 kHz split-beam transducer during the summers of 2011 and 2012 were used to quantify seasonal declines in fish abundance in a boreal reservoir in Manitoba, Canada. Fish densities were sufficiently low to enable single target resolution and tracking. Target strengths converted to log2-based size-classes indicated that smaller fish were consistently more abundant than larger fish by a factor of approximately 3 for each halving of length. For all size classes, in both years, abundance (natural log) declined linearly over the summer at rates that varied from -0.067 x day(-1) for the smallest fish to -0.016 x day(-1) for the largest (R2 = 0.24-0.97). Inter-annual comparisons of size-based abundance suggested that for larger fish (>16 cm), mean winter decline rates were an order of magnitude lower (-0.001 x day(-1)) and overall survival higher (71%) than in the main summer fishing season (mean loss rate -0.038 x day(-1); survival 33%). We conclude that size-based acoustic survey methods have the potential to assess within-season fish abundance dynamics, and may prove useful in long-term monitoring of productivity and hence management of boreal aquatic ecosystems.

  14. Sample Size and Statistical Conclusions from Tests of Fit to the Rasch Model According to the Rasch Unidimensional Measurement Model (Rumm) Program in Health Outcome Measurement.

    Science.gov (United States)

    Hagell, Peter; Westergren, Albert

    Sample size is a major factor in statistical null hypothesis testing, which is the basis for many approaches to testing Rasch model fit. Few sample size recommendations for testing fit to the Rasch model concern the Rasch Unidimensional Measurement Models (RUMM) software, which features chi-square and ANOVA/F-ratio based fit statistics, including Bonferroni and algebraic sample size adjustments. This paper explores the occurrence of Type I errors with RUMM fit statistics, and the effects of algebraic sample size adjustments. Data with simulated Rasch model fitting 25-item dichotomous scales and sample sizes ranging from N = 50 to N = 2500 were analysed with and without algebraically adjusted sample sizes. Results suggest the occurrence of Type I errors with N less then or equal to 500, and that Bonferroni correction as well as downward algebraic sample size adjustment are useful to avoid such errors, whereas upward adjustment of smaller samples falsely signal misfit. Our observations suggest that sample sizes around N = 250 to N = 500 may provide a good balance for the statistical interpretation of the RUMM fit statistics studied here with respect to Type I errors and under the assumption of Rasch model fit within the examined frame of reference (i.e., about 25 item parameters well targeted to the sample).

  15. Relationship between pineal cyst size and aqueductal CSF flow measured by phase contrast MRI.

    Science.gov (United States)

    Bezuidenhout, Abraham F; Kasper, Ekkehard M; Baledent, Olivier; Rojas, Rafael; Bhadelia, Rafeeque A

    2018-02-23

    Most patients with pineal cysts referred for neurosurgical consultation have no specific symptoms or objective findings except for pineal cyst size to help in management decisions. Our purpose was to assess the relationship between pineal cyst size and aqueductal CSF flow using PC-MRI. Eleven adult patients with pineal cysts (> 1-cm in size) referred for neurosurgical consultations were included. Cyst volume was calculated using 3D T1 images. PC-MRI in axial plane with velocity encoding of 5 cm/sec was used to quantitatively assess CSF flow through the cerebral aqueduct to determine the aqueductal stroke volume, which was then correlated to cyst size using Pearson's correlation. Pineal cysts were grouped by size into small (6/11) and large (5/11) using the median value to compare aqueductal stroke volume using Mann-Whitney test. Patients were 39 ± 13 years (mean ± SD) of age, and 10/11 (91%) were female. There was significant negative correlation between cyst volume and aqueductal stroke volume (r=0.74; p=0.009). Volume of small cysts (4954±2157 mm3) was significantly different compared to large cysts (13752±3738 mm3; p= 0.008). The aqueductal stroke volume of patients harboring large cysts 33±8 μL/cardiac cycle was significantly lower than that of patients with small cysts 96±29 μL/cardiac cycle (p=0.008). Aqueductal CSF flow appears to decrease with increasing pineal cyst size. Our preliminary results provide first evidence that even in the absence of objective neurological findings or hydrocephalus; larger pineal cysts already display decreased CSF flow through the cerebral aqueduct.

  16. Aerosol Size Distributions During ACE-Asia: Retrievals From Optical Thickness and Comparisons With In-situ Measurements

    Science.gov (United States)

    Kuzmanoski, M.; Box, M.; Box, G. P.; Schmidt, B.; Russell, P. B.; Redemann, J.; Livingston, J. M.; Wang, J.; Flagan, R. C.; Seinfeld, J. H.

    2002-12-01

    As part of the ACE-Asia experiment, conducted off the coast of China, Korea and Japan in spring 2001, measurements of aerosol physical, chemical and radiative characteristics were performed aboard the Twin Otter aircraft. Of particular importance for this paper were spectral measurements of aerosol optical thickness obtained at 13 discrete wavelengths, within 354-1558 nm wavelength range, using the AATS-14 sunphotometer. Spectral aerosol optical thickness can be used to obtain information about particle size distribution. In this paper, we use sunphotometer measurements to retrieve size distribution of aerosols during ACE-Asia. We focus on four cases in which layers influenced by different air masses were identified. Aerosol optical thickness of each layer was inverted using two different techniques - constrained linear inversion and multimodal. In the constrained linear inversion algorithm no assumption about the mathematical form of the distribution to be retrieved is made. Conversely, the multimodal technique assumes that aerosol size distribution is represented as a linear combination of few lognormal modes with predefined values of mode radii and geometric standard deviations. Amplitudes of modes are varied to obtain best fit of sum of optical thicknesses due to individual modes to sunphotometer measurements. In this paper we compare the results of these two retrieval methods. In addition, we present comparisons of retrieved size distributions with in situ measurements taken using an aerodynamic particle sizer and differential mobility analyzer system aboard the Twin Otter aircraft.

  17. Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

    Science.gov (United States)

    Johnson, Garrett G R J; Zeiler, Frederick A; Unger, Bertram; Hansen, Gregory; Karakitsos, Dimitrios; Gillman, Lawrence M

    2016-12-01

    Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland-Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland-Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.

  18. Influence of BMI and dietary restraint on self-selected portions of prepared meals in US women.

    Science.gov (United States)

    Labbe, David; Rytz, Andréas; Brunstrom, Jeffrey M; Forde, Ciarán G; Martin, Nathalie

    2017-04-01

    The rise of obesity prevalence has been attributed in part to an increase in food and beverage portion sizes selected and consumed among overweight and obese consumers. Nevertheless, evidence from observations of adults is mixed and contradictory findings might reflect the use of small or unrepresentative samples. The objective of this study was i) to determine the extent to which BMI and dietary restraint predict self-selected portion sizes for a range of commercially available prepared savoury meals and ii) to consider the importance of these variables relative to two previously established predictors of portion selection, expected satiation and expected liking. A representative sample of female consumers (N = 300, range 18-55 years) evaluated 15 frozen savoury prepared meals. For each meal, participants rated their expected satiation and expected liking, and selected their ideal portion using a previously validated computer-based task. Dietary restraint was quantified using the Dutch Eating Behaviour Questionnaire (DEBQ-R). Hierarchical multiple regression was performed on self-selected portions with age, hunger level, and meal familiarity entered as control variables in the first step of the model, expected satiation and expected liking as predictor variables in the second step, and DEBQ-R and BMI as exploratory predictor variables in the third step. The second and third steps significantly explained variance in portion size selection (18% and 4%, respectively). Larger portion selections were significantly associated with lower dietary restraint and with lower expected satiation. There was a positive relationship between BMI and portion size selection (p = 0.06) and between expected liking and portion size selection (p = 0.06). Our discussion considers future research directions, the limited variance explained by our model, and the potential for portion size underreporting by overweight participants. Copyright © 2016 Nestec S.A. Published by Elsevier Ltd

  19. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  20. Comparison of manual and automated measurements of monodominant follicle diameter with different follicle size in infertile patients.